IEC Contactor Specifications TD 100 Td013 En P
User Manual: TD 100
Open the PDF directly: View PDF .
Page Count: 146
Download | |
Open PDF In Browser | View PDF |
Technical Data IEC Contactor Specifications Bulletin Numbers 100/104-K, 100/104-C, 100/104S-C, 100/104-E, 100S-E, 100/104-D, 100S-D, 100-G, 100Q-C Page Topic Page Product Line Overview 3 100-D/104-D, 100S-D Contactors 101 IEC Contactors 3 Product Selection—100-D/104-D Contactors Safety Contactors 4 Product Selection—100S-D Safety Contactors 105 5 Specifications 108 Product Selection 5 Life-Load Curves 118 Specifications 10 Approximate Dimensions 120 Life-Load Curves 14 Accessories 122 Approximate Dimensions 16 Renewal Parts 129 Accessories 17 100-G Contactors Topic 100-K/104-K Miniature Contactors 101 131 100-C/104-C, 100S-C/104S-C, 100Q-C Contactors 21 Product Selection—100-G Contactors Product Selection—100-C/104-C Contactors 21 Specifications 132 Product Selection—100S-C/104S-C Safety Contactors 28 Life-Load Curves 137 Product Selection—100Q-C Capacitor-switching Contactors 38 Permissible Switching Rate 139 Specifications 40 Approximate Dimensions 141 Life-Load Curves 51 Accessories 143 Maximum Operating Rates 57 Renewal Parts 144 Approximate Dimensions 61 Accessories 65 Renewal Parts 70 100-E/104-E, 100S-E/104S-E Contactors 73 Product Selection—100-E/104-E Contactors 73 Product Selection—100S-E Safety Contactors 74 Specifications 75 Approximate Dimensions 92 Accessories 96 Renewal Parts 99 131 IEC Contactor Specifications Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Description Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines for installing a Rockwell Automation industrial system. Product Certifications website, https://www.rockwellautomation.com/global/certification/ overview.page Provides declarations of conformity, certificates, and other certification details. You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative. 2 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Product Line Overview IEC Contactors Bulletin No. 100-K/104-K 100-C/104-C 100-E/104-E Screw Terminals ✓ ✓ Thru-hole Spring Terminals Max.Current Ie Current Rating Features ✓ (5…9 A) ✓ (9…16 A) 12 A 97 A 2650 A 9…97 A 116…2650 A 5…12 A • Mini-contactors • Uniform panel mounting dimensions • Panel mounting or mounting on 35 mm DIN Rail • AC or DC coil control • Made of environmentally friendly materials • Panel mounting or mounting • Panel mounting on 35 mm DIN Rail • E116…E370 • AC or DC coil control AC/DC electronic coil or • Reversible coil terminals (line optional with PLC interface or load side) E400…E2650 • Common accessories AC/DC with PLC interface • Made of environmentally friendly materials • Made of environmentally 100-D/104-D Thru-hole, threaded (630…860 A) 100-G Thru-hole — — 860 A 1200 A 115…860 A • Panel mounting only • Made of environmentally friendly materials • AC or DC coil control (conventional or electronic) • Integrated PLC interface (electronic coil) 550…1200 A • • • • • Panel mounting AC or DC coil control Horizontal or vertical interlock Latching 4th pole friendly materials Contacts 3 power poles with internal N.O. or 3 main poles with 2 auxiliary N.C. auxiliary contact, or 4 power 3 power poles with internal N.O. or contacts N.C. auxiliary contact or 4 power poles. (1 N.O. and 1 N.C.) poles. Optional front- or sideOptional side-mounted Optional front-mounted 2- or 4- mounted 1-, 2- or 4-pole external 2-pole external auxiliary contact pole external auxiliary contact auxiliary contact block. block. block. AC = 24…600V, 50/60Hz DC = 12…250V AC = 12…600V, 50/60Hz DC = 9…250V 24…500V 50/60 Hz/DC Conventional Coils Cat. Nos. 100-D115…D180 AC: 24…550V 50 Hz, 24…600V 60Hz, 100…277V 50/60Hz DC: 24…250V DC Electronic Coils Cat. Nos. 100-D115…D300 AC: 24…500V 50/60 Hz DC: 24…255V DC Cat. Nos. 100-D420 AC: 42…500V 50/60 Hz DC: 48…255V DC Cat. Nos. 100-D630…D860 AC: 100…600V 50/60 Hz DC: 110…255V DC Electronic or bimetallic Electronic or bimetallic Electronic Electronic Coil Voltages Optional Overload Relays Optional Accessories Standards/Certifications 3 power poles with external N.O. 3 power poles with N.O. and N.C. and N.C. side-mounted auxiliary front-mounted auxiliary contact. contact. Optional side-mounted Optional 4th pole and auxiliary 2-pole external auxiliary contact contacts blocks • Front-mount auxiliary contacts • Surge suppressors • Electronic timers • Mechanical interlocks • Front or side-mount auxiliary contacts • Surge suppressors • Electronic or pneumatic timers • Mechanical interlocks • Mechanical latches • Side-mount auxiliary contacts • Mechanical interlocks • Terminal lugs • Terminal shields • Connecting bars • • • • • • • • • • • • • • • • • • • • • • • • • • • • • UL CSA IEC CE Marked CCC UL CSA IEC CE Marked CCC EN/IEC CE Marked cULus CCC EAC C-tick Side-mount auxiliary contacts Surge suppressors IP20 terminal blocks Terminal shields Terminal covers Connecting components Terminal lugs Mechanical/electrical interlocks UL CSA IEC CE Marked CCC(115…180 A conventional coil; 140…420 A - electronic coil) Rockwell Automation Publication 100-TD013F-EN-P - November 2017 AC = 110…480V, 50/60Hz DC = 100…440V Electronic • • • • • Auxiliary contact 4th pole Vertical interlock Horizontal interlock Mechanical latch • • • • UL CSA IEC CE Marked 3 Safety Contactors Bulletin No. Screw Terminals Max.Current Ie Current Rating Features 100S-C/104S-C 100S-E 100S-D ✓ Thru-hole Thru-hole, threaded (630…860 A) 97 A 750 A 860 A 9…97 A 116…750 A 115…860 A • Mirror contact performance on auxiliary contacts • Mirror contact performance on auxiliary contacts, • Red N.C. low-power auxiliary contact used for feedback which are required in feedback circuit for modern circuit safety applications. • SUVA third-party certification • The N.C. auxiliary contacts will not change state when Permanently fixed a power contact welds. Protective cover to prevent manual operation • AC and DC operating coils • "Mirror Contact" symbol on front • SUVA third-party certification Red contact housing for easy identification • AC and DC operating coils Incorporates IEC 947-5-1 “Mechanically Linked” • "Mirror Contact" symbol • Positively guided/mechanically linked auxiliary contacts • Front-mounted auxiliary contacts: – – – – symbol – Optional gold-plated bifurcated versions Contacts • AC and DC operating coils • SUVA third-party certification 3 main poles with N.C. mechanically linked or mirror feedback contacts 3 main poles with N.C. mirror feedback contacts Conventional Coils Cat. Nos. 100S-D115…D180 AC: 24…550V, 50 Hz; 24…600V, 60Hz; 100…277V, 50/ 60Hz DC: 24…250V Coil Voltages AC = 12…600V, 50/60Hz DC = 12…250V Optional Accessories • • • • Standards Compliance • EN/IEC 60947-4 • IEC 60947-5-1 Annex L — Mechanically Linked Contacts • IEC 60947-4-1 Annex H — Mirror Contacts • UL 508 • CSA C22.2 No. 14 • EN50205 • cULus Listed (File No. E3125; Guide NLDX, NLDX7) • SUVA Third-Party Certified • CE Marked Certifications 4 3 main poles with N.C. mirror feedback contacts Side-mount auxiliary contacts Surge suppressors Electronic timers Mechanical interlocks 24…500V 50/60 Hz/DC • • • • • • • • • • Side-mount auxiliary contacts Terminal shields Terminal lugs Terminal enlargements Terminal extensions Connection bars for 140G molded case circuit breakers, 140MG motor protection circuit breakers, and 140MG motor circuit protectors EN/IEC 60947-4-1 IEC 60947-4-1, Annex F — Mirror Contacts UL 60947-4-1 CSA C22.2, No. 60947-4-1 • • • • • • • • • • • • • • • • • • • • • cULus Listed (File No. E41850; Guide No. NLDX, NLDX7) CE Marked CCC UL CSA EAC RCM (C-tick) SUVA Third-Party Certified • • • • Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Electronic Coils Cat. Nos. 100S-D115…D300 AC: 24…500V, 50/60 Hz DC: 24…255V Cat. Nos. 100S-D420 AC: 42…500V 50/60 Hz DC: 48…255V Cat. Nos. 100S-D630…D860 AC: 100…600V, 50/60 Hz DC: 110…255V Side-mount auxiliary contacts Surge suppressors IP20 terminal blocks Terminal shields Terminal covers Connecting components Terminal lugs Mechanical/electrical interlocks EN/IEC 60947-4 IEC 60947-4-1 IEC 60947-4-1/A1: 2002-09, Annex F UL 508 CSA C22.2, No. 14 cULus Listed (File No. E3125; Guide No. NLDX, NLDX7) SUVA Third-Party Certified CE Marked CCC (115…180 A - conventional coil; 140…420 A electronic coil) 100-K/104-K Miniature Contactors Product Selection • • • • • • • • • 3-Pole AC- and DC-Operated Contactors Compact size Same dimensions for AC and DC Full-voltage non-reversing and reversing contactors 100-K Miniature 104-K Reversing Miniature Contactor Contactor 5, 9, and 12 A contactors rated at 690V IP2X finger protection Optional integrated surge suppressor Compatible with Bulletin 193-K bimetallic overload relay Mirror contacts per IEC 60947-4-1 and mechanically linked contacts per IEC 60947-5-1 on main unit Allen-Bradley Bulletin 100-K miniature contactors are designed for commercial and light industrial applications where panel space is at a premium. These miniature devices, while 45 mm wide, are shallower and have less panel depth requirements than standard IEC contactors. The miniature contactors have been designed with flexibility in mind. They are available with AC or DC operating coils, several contact ratings, and optional 2- or 4-pole adder decks in a variety of auxiliary contact configurations. 3-Pole AC- and DC-Operated Contactors Rated Operational Current Ie [A] 40 °C 230V Ratings for switching AC motors - AC-2, AC-3, AC-4 3-phase kW (50 Hz) Hp (60 Hz) 1-Phase 3-Phase 400/415V 500V 690V 115V 230V 200V 230V 460V Auxiliary Contacts AC-3 Screw Terminals AC-1 575V 5 20 1.5 2.2 2.2 2.2 1/2 1 1-1/2 1-1/2 3 3 9 20 3 4 4 4 1/2 1-1/2 2 2 5 5 12 20 3 5.5 5.5 5.5 3/4 2 3 3 7-1/2 7-1/2 Pkg. Qty.(1) Cat. No. N.O. N.C. 1 0 1 0 1 0 0 1 0 1 0 1 1 1 1 1 1 1 100-K0510 100-K0501 100-K0910 100-K0901 100-K1210 100-K1201 1 0 1 0 0 1 0 1 1 1 1 1 100-KR0510 100-KR0501 100-KR0910 100-KR0901 Spring Clamp Terminals (1) 5 10 1.5 2.2 2.2 2.2 1/3 3/4 1-1/2 1-1/2 3 3 9 10 2.2 4 4 4 1/3 1 2 2 5 5 May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 100-K09ZJ10M. Coil voltage code — see page 7. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 5 4-Pole AC- and DC-Operated Contactors 40 °C (1) Contact Configuration, Main Poles Ratings for switching AC motors - AC-2, AC-3 Rated Operational Current Ie [A] 3-phase kW (50 Hz) 230V 400/415V 500V Hp (60 Hz) 690V 1-Phase 115V 230V 200V 3-Phase 230V 460V 1 1-1/2 1-1/2 3 3 1/2 1-1/2 2 2 5 5 3/4 2 3 3 7-1/2 7-1/2 AC-3 AC-1 5 20 1.5 2.2 2.2 2.2 1/2 9 20 3 4 4 4 12 20 3 5.5 5.5 5.5 575V N.O. 4 3 2 4 3 2 4 3 2 N.C. 0 1 2 0 1 2 0 1 2 Pkg. Qty.(1) Cat. No. 1 1 1 1 1 1 1 1 1 100-K05400 100-K05300 100-K05200 100-K09400 100-K09300 100-K09200 100-K12400 100-K12300 100-K12200 May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 100-K09ZJ400M. Coil voltage code — see page 7. Reversing AC- and DC-Operated Contactors Bulletin 104-K reversing contactors are factory assembled and include contactors, mechanical interlock (Cat. No. 100-KMCH) and wiring kit (Cat. No. 100-KPR) for power and control circuit (electrical interlock). 40 °C AC-3 5 9 12 (1) AC-1 20 20 20 Auxiliary Contacts per Contactor(1) Ratings for switching AC motors - AC-2, AC-3, AC-4 Rated Operational Current Ie [A] 3-phase kW (50 Hz) Hp (60 Hz) 230V 400/415V 500V 690V 1.5 3 3 2.2 4 5.5 2.2 4 5.5 2.2 4 5.5 1-Phase 115V 230V — — — — — — 200V 1-1/2 2 3 3-Phase 230V 460V 1-1/2 3 2 5 3 7-1/2 Cat. No. 575V 3 5 7-1/2 Used for electrical interlocking Coil voltage code — see page 7. 6 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 N.O. 0 0 0 N.C. 1 1 1 104-K0502 104-K0902 104-K1202 Coil Voltage Codes Coil Voltage Code for screw type terminal versions The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 60 Hz: Cat. No. 100-K0910 becomes Cat. No.100-K09D10. AC Voltages [V] 50 Hz 60 Hz 50/60 Hz 24 110 120 230 240 400 480 600 — — KJ D — — — D — — — KF — — KA — — KN — B — — VC — DC Voltages [V] Standard with Integrated Diode 12 24 110 125 220 250 ZQ — ZJ DJ ZD — ZS — ZA — ZT — Coil Voltage Code for spring clamp type terminal versions The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 60 Hz: Cat. No. 100-KR0910 becomes Cat. No.100-KR09D10. AC Voltages [V] 50 Hz 60 Hz 50/60 Hz DC Voltages [V] Standard with Integrated Diode 24 110 120 230 — — KJ D — — — D — — — KF 24 110 ZJ DJ ZD — Rockwell Automation Publication 100-TD013F-EN-P - November 2017 7 Assignment of Contacts Table valid for: AC / DC = 0.85…1.1 x Us, Tamb. = -25 °C…+60 °C, normal position (horizontal rail mounting) Device Combinations in Accordance with IEC 60947-1 / -4-1 Auxiliary Contact Blocks(1) Circuit Diagram 100-K0510 100-K0910 100-K1210 Control A1 1 3 5 100-K Miniature Contactors (AC and DC Control) 100-K0501 100-K05400 100-K05300 100-K0901 100-K09400 100-K09300 100-K1201 100-K12400 100-K12300 13 A1 1 3 5 A2 2 4 6 14 A1 1 21 K1 K1 3 5 A2 2 4 6 22 A1 1 7 K1 3 5 100-K05200 100-K09200 100-K12200 R7 K1 A2 2 4 6 8 A1 1 3 R5 R7 A2 2 4 R6 R8 K1 A2 2 4 6 R8 Front Mounting 100-KFA02E 51 61 AC/DC (2) 01 + 02 = 03 (3) (2) (2)(3) — AC/DC 10 + 02 = 12 — 00 + 02 = 02 00 + 02 = 02 (3) — AC/DC (2) 01 + 11 = 12 (2) (2) (2) AC/DC 10 + 11 = 21 — 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11 AC/DC 10 + 11 = 21 (2) 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11 AC/DC (2) 01 + 20 = 21 (2) (2) (2) AC/DC 10 + 20 = 30 (2) 00 + 20 = 20 00 + 20 = 20 00 + 20 = 20 AC/DC (2)(3) — (2)(3) — — AC/DC 10 + 04 = 14 (3) — 00 + 04 = 04 (3) — — AC/DC (2) 01 + 13 = 14 (3) (2) (2)(3) — AC/DC 10 + 13 = 23 (2)(3) 00 + 13 = 13 00 + 13 = 13 (3) — AC/DC (2) 01 + 22 = 23 (3) (2) (2)(3) — AC/DC 10 + 22 = 32 — 00 + 22 = 22 00 + 22 = 22 (3) — AC/DC 10 + 22 = 32 (2)(3) 00 + 22 = 22 00 + 22 = 22 (3) — AC/DC (2) — (2)(4) — — 52 62 100-KFC02 21 31 22 32 100-KFA11E 53 61 54 62 100-KFB11 21 33 22 34 100-KFC11 23 31 24 32 100-KFA20E 53 63 54 64 100-KFC20 23 33 24 34 100-KFA04E 51 61 71 81 52 62 72 82 100-KFC04 21 31 41 51 22 32 42 52 100-KFA13E 53 61 71 81 54 62 72 82 100-KFC13 23 31 41 51 24 32 42 52 100-KFA22Z 53 83 61 71 54 84 62 72 100-KFB22 43 53 21 31 44 54 22 32 100-KFC22 23 53 31 41 24 54 32 42 100-KFA31Z 53 73 83 61 54 74 84 62 8 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Auxiliary Contact Blocks(1) Circuit Diagram 100-K0510 100-K0910 100-K1210 Control A1 1 3 5 100-K Miniature Contactors (AC and DC Control) 100-K0501 100-K05400 100-K05300 100-K0901 100-K09400 100-K09300 100-K1201 100-K12400 100-K12300 13 A2 2 100-KFC31 23 43 53 31 A1 1 3 5 4 6 AC/DC 10 + 31 = 41 (4) AC/DC (2) AC/DC 10 + 40 = 50 14 A1 1 21 K1 K1 3 5 A2 2 4 — 6 22 A1 1 7 K1 3 5 100-K05200 100-K09200 100-K12200 R7 K1 A2 2 4 6 8 A1 1 3 R5 R7 A2 2 4 R6 R8 K1 A2 2 4 6 R8 00 + 31 = 31 (4) — — (2) (2) (2) 00 + 40 = 40 00 + 40 = 40 00 + 40 = 40 24 44 54 32 100-KFA40E 53 63 73 83 54 64 74 84 100-KFC40 23 33 43 53 (2) 24 34 44 54 (1) (2) (3) (4) For other operating limits, please contact your local Rockwell Automation sales office or Allen-Bradley distributor Combination possible but not recommended, due to repeating or not consecutive sequence numbering Tamb max. +40 °C Tamb max. +40 °C and only allowed for coil voltage 24V DC or 230V AC Rockwell Automation Publication 100-TD013F-EN-P - November 2017 9 Specifications 100-KR 100/104-K 05 09 05 09 Coil Type: Conventional X X X X AC-1 Active Power Load (50 Hz); Ambient temperature 40 °C ≤500V [A] 10 10 20 20 690V [A] 10 10 20 20 230V [kW] 4 4 8 8 240V [kW] 4 4 8.3 8.3 Rated Operational Current, Ie 400V [kW] 6.9 6.9 14 14 415V [kW] 7 7 14 14 500V [kW] 8.7 8.7 17 17 690V [kW] 12 12 24 24 AC-1 Active Power Load (50 Hz); Ambient temperature 60 °C ≤500V [A] 10 10 16 16 690V [A] 10 10 16 16 230V [kW] 4 4 6.4 6.4 240V [kW] 4 4 6.7 6.7 Rated Operational Current, Ie 400V [kW] 6.9 6.9 11 11 415V [kW] 7 7 12 12 500V [kW] 8.7 8.7 14 14 690V [kW] 12 12 19 19 Switching of 3-phase Motors; (50 Hz) Ambient temperature 60 °C, AC-2, AC-3 230V [A] 6.3 8.5 6.3 11.3 240V [A] 6.3 8.5 6.3 11.3 400V [A] 4.9 8.5 4.9 8.5 415V [A] 4.9 8.5 4.9 8.5 500V [A] 3.9 6.8 3.9 6.8 690V [A] 2.8 4.9 2.8 4.9 Rated Operational Current, Ie 230V [kW] 1.5 2.2 1.5 3 240V [kW] 1.5 2.2 1.5 3 400V [kW] 2.2 4 2.2 4 415V [kW] 2.2 4 2.2 4 500V [kW] 2.2 4 2.2 4 690V [kW] 2.2 4 2.2 4 Load Carrying Capacity per UL/CSA General Purpose Current (enclosed) [A] 9 9 12 15 115V [A] 7.2 7.2 9.8 9.8 230V [A] 6.9 8 8 10 Rated power (enclosed) 1-phase 115V [Hp] 1/3 1/3 0.5 0.5 230V [Hp] 3/4 1 1 1.5 200V [A] 6.9 7.8 6.9 7.8 230V [A] 6 6.8 6 6.8 460V [A] 4.8 7.6 4.8 7.6 575V [A] 3.9 6.1 3.9 6.1 Rated power (enclosed) 3-phase 200V [Hp] 1.5 2 1.5 2 230V [Hp] 1.5 2 1.5 2 460V [Hp] 3 5 3 5 575V [Hp] 3 5 3 5 10 12 X 20 20 8 8.3 14 14 17 24 16 16 6.4 6.7 11 12 14 19 11.3 11.3 11.5 11.5 9.2 6.7 3 3 5.5 5.5 5.5 5.5 18 13.8 12 0.75 2 11 9.6 11 9 3 3 7.5 7.5 100/104-K 05 09 Coil Type: Conventional X X Switching of 3-phase Motors, (50 Hz); Ambient temperature 60 °C, AC-4 230V [A] 6.3 11.3 240V [A] 6.3 11.3 400V [A] 4.9 8.5 415V [A] 4.9 8.5 500V [A] 3.9 6.8 690V [A] 2.8 4.9 230V [Hp] 1.5 3 240V [Hp] 1.5 3 400V [Hp] 2.2 4 415V [Hp] 2.2 4 500V [Hp] 2.2 4 690V [Hp] 2.2 4 AC-4 at approximately 200,000 operations 230V [A] 2.3 3.9 240V [A] 2.3 3.9 400/415V [A] 2 3.6 500V [A] 1.9 3.2 (1) 230V [Hp] 0.37 0.75 240V (1) [Hp] 0.37 0.75 400V (1) [Hp] 0.75 1.5 415V (1) [Hp] 0.75 1.5 500V (1) [Hp] 0.75 1.5 Max. switching frequency Ops/hour 250 250 Wye-Delta (60 Hz) 200V [Hp] 2.2 3 230V [Hp] 2.2 3 460V [Hp] 5 7.5 575V [Hp] 5 7.5 Star-Delta Starting (50 Hz) ≤ 230V [A] 11.3 20 ≤ 240V [A] 11.3 20 400V [A] 8.5 15.5 415V [A] 8.5 15.5 500V [A] 6.8 12.4 690V [A] 4.9 8.9 230V (1) [kW] 3 5.5 240V (1) [kW] 3 5.5 400V (1) [kW] 4 7.5 415V (1) [kW] 4 7.5 500V (1) [kW] 4 7.5 690V (1) [kW] 4 7.5 (1) Power ratings at 50 Hz: Preferred values according to IEC 60072-1 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 12 X 11.3 11.3 11.5 11.5 9.2 6.7 3 3 5.5 5.5 5.5 5.5 3.9 3.9 3.6 3.2 0.75 0.75 1.5 1.5 1.5 250 5 5 10 10 20 20 15.5 15.5 12.4 8.9 5.5 5.5 7.5 7.5 7.5 7.5 100/104-K 05 09 12 X X X Coil Type: Conventional Switching of Power Transformers, AC-6a (50 Hz) Inrush Current =n Rated transformer current ≤ 230V [A] 2.9 5.4 5.4 ≤ 240V [A] 2.9 5.4 5.4 ≤ 400V [A] 2.4 4.1 5.4 ≤ 415V [A] 2.4 4.1 5.4 ≤ 500V [A] 1.8 3.2 3.2 230V n= 30 [kVA] 1.2 2 2 240V [kVA] 1.2 2 2 400V [kVA] 1.7 2.8 3.4 415V [kVA] 1.7 2.8 3.4 500V [kVA] 1.7 2.8 3.4 690V [kVA] 2 4 5 Switching of Lamps Gas discharge lamps AC-5a, 40 °C open [A] 18 18 18 enclosed [A] 14.5 14.5 14.5 Individually compensated: Max. capacitance at expected 10 kA [F] 750 750 750 Short-circuit current of 20 kA [F] 400 400 400 Filament AC-5b 230/240V [A] 5 9 9 Switching of Low Inductive Loads in Home Appliances and Similar Applications per IEC 61095 (50 Hz) 230V [A] 20 20 20 AC-7a 400V [A] 20 20 20 Switching of Motor Load for Home Appliances (50 Hz) 230V [A] 6 11 11 AC-7b 400V [A] 6 11 11 Switching of Hermetically Sealed Cooling Compressor Motors - manual reset of overload release (50 Hz) 400V [A] 11 18 18 AC-8a 500V [A] 10 15 15 Switching of DC Loads Non-inductive or slightly inductive loads or resistance furnaces DC-1, 60 °C [A] 6 9 9 24V 48/60V [A] 4/1 6/1.5 6/1.5 110V [A] 0.6 1 1 1 pole 220V [A] 0.2 0.3 0.3 440V [A] 0.08 0.1 0.1 [A] 6 9 9 24V 48/60V [A] 6 8 8 110V [A] 4 6 6 2 poles in series 220V [A] 0.8 1.2 1.2 440V [A] 0.2 0.3 0.3 Coil Type: Conventional 24V [A] 48/60V [A] 110V [A] 220V [A] 440V [A] 3 poles in series 05 X 6 6 6 3 0.4 Shunt-wound Motors Starting, reverse current braking, reversing, stepping DC-3, 60 °C [A] 5 24V 48/60V [A] 4 110V [A] 2 3 poles in series 220V [A] 0.8 440V [A] 0.15 Series-wound Motors Starting, reverse current braking, reversing, stepping DC-5, 60 °C 24V [A] 5 48/60V [A] 2 3 poles in series 110V [A] 0.6 220V [A] 0.1 Short Time Withstand ICW, 60 °C 10 s [A] 60 Resistance and Power Dissipation Main current circuit resistance [m] 2.2 Power dissipation by all circuits at Ie AC-3/400V [W] 0.3 Total power dissipation AC control [W] 2.1 At Ie AC-3/400V DC control [W] 2.9 (electronic) Lifespan Mechanical AC control [Mil. operations] 15 Mechanical DC control [Mil. operations] 15 Electrical AC-3 (400 V) [Mil. operations] 0.7 Weight Non-Rev. kg (lbs.) AC Rev. kg (lbs.) Non-Rev. kg (lbs.) DC Rev. kg (lbs.) Coil Type: Conventional 100-KR 05 09 X X 100/104-K 09 12 X X 9 9 9 9 9 9 4 4 0.6 0.6 9 6 3 1.2 0.2 9 6 3 1.2 0.2 9 3 1 0.1 96 9 3 1 0.1 96 2.2 0.9 2.2 0.9 2.7 2.7 3.5 3.5 15 15 0.7 15 15 0.7 0.16 (0.35) 0.4 (0.88) 0.2 (0.44) 0.48 (1.06) 05 X 100/104-K 09 12 X X (1) Conductor Cross Sections - Main Contacts Terminal type 1 conductor 2 conductors 1 conductor 2 conductors Recommended torque Cross section per UL/CSA Recommended torque [mm2] 0.50…2.5 [mm2] 0.50…2.5 [mm2] 0.75…2.5 (2) [mm2] 0.75…2.5 (2) [N•m] — [AWG] 18…14(2) [lb-in] — 0.75…2.5 0.75…2.5 1…4 1…2.5+ 1…4 1.2 18…12 10.6 (1) Pozidriv No. 2 / Blade No. 3 screw (2) Fine- or coarse-stranded only Rockwell Automation Publication 100-TD013F-EN-P - November 2017 11 Auxiliary Contacts, Auxiliary Contact Blocks, and Pneumatic Timers Short-Circuit Coordination Data See https://www.rockwellautomation.com/global/support/ global-sccr.page for complete short-circuit current ratings. 100/104-K 05 09 12 Coil Type: Conventional X X X Short Circuit Coordination (Max. Fuse or Circuit Breaker Rating) Per IEC 60947-4-1 (contactor and fuses only) DIN Fuses- gG, gL 50 kA Available Fault Current Type "1"(690V) [A] 35 35 35 Type "2"(400V) [A] 16 20 20 Per UL 508 and CSA 22.2 No. 14 (contactor and fuses or circuit breaker only) UL Class K5 and RK5 Fuses 5 kA Available Fault Current UL Listed Combination (600V) [A] 40 40 40 UL Class CC and CSA HRCI-MISC Fuses UL Listed Combination (600V) [A] 30 30 30 UL Class J and CSA HRCI-J Fuses 50 kA Available Fault Current UL Listed Combination (600V) [A] 30 30 30 AC-12 Ith AC-15 at rated voltage of Coil Type: Operating Limits 50 Hz, 60 Hz, 50/60 Hz DC (conventional) Conventional pick-up [x Us] 0.85…1.1 dropout [x Us] pick-up [x Us] dropout [x Us] 0.2…0.75 0.8…1.1 0.7…1.25(1) 0.1…0.75 pick-up hold-in pick-up hold-in [VA] [VA/W] [W] [W] 35 5/1.8 cold 3.0, warm 2.6 cold 3.0, warm 2.6 DC-14L/R <15 ms inductive loads with economy resistor in series at DC-13 switching electromagnets at Coil Consumption 50 Hz, 60 Hz, 50/60 Hz DC (conventional) Operating Times closing delay [ms] opening delay [ms] 15…33 closing delay [ms] 15…28 opening delay [ms] 18…40 closing delay [ms] 6…12 With integrated diode opening delay [ms] 8…12 With external diode opening delay [ms] 35…50 AC With RC module DC (conventional) 15…40 [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] 10 6 6 6 6 3 3 1.8 1.8 1.4 1.0 10 6 3 3 3 2 2 1.2 1.2 1.0 0.6 24V DC 48V DC 110V DC 220V DC 440V DC 24V DC 48V DC 110V DC 220V DC 440V DC 24V DC 48V DC 110V DC 220V DC 440V DC [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] 6 4 0.6 0.2 0.08 4 2.5 0.4 0.12 0.05 2.8 1.2 0.55 0.27 0.15 — — — — — — — — — — 2.3 1 0.55 0.27 0.15 [A] 10 10 [A] 10 10 15V/ 10 mA 15V/ 2 mA Fuse gG Min. switching capacity according to IEC 60947-5-4 Load Carrying Capacity per UL/CSA Rated voltage AC Continuous rating 40 °C Switching capacity AC Rated voltage DC Switching capacity DC (1) For 9, 12, 24, and 110V DC coils 12 at 40 °C at 60 °C 24V 42/48V 120V 230V 240V 400V 415V 500V 690V Switching of DC Loads DC-12 L/R < 1 ms resistive loads at 100/104-K 09 12 X X Front mounted Switching of AC Loads Coil Data 05 X Internal Rockwell Automation Publication 100-TD013F-EN-P - November 2017 [V] [A] [A] [V] [A] max.600 10 A600 B600 max.600 Q600 General Attribute Rated Isolation Voltage Ui IEC UL,CSA Rated Impulse Voltage Withstand Uimp Rated Voltage Ue AC 50/60 Hz DC Value [V] [V] [kV] 690 600 6 [V] [V] 230, 240, 400, 415, 460, 500, 575, 690 24, 48, 110, 220, 440 Class F per IEC 60085 Class 105 insulation system per UL 508 AC 50/60 Hz, DC [°C] [°C] -55…+80 -25…+60 Insulation Class of the Coil Rated coil frequency Ambient Temperature Storage Operation at rated voltage at 70 °C 15% current reduction against 60 °C values Climatic Withstand Max. Altitude of Installation Site IEC60068-2-30 [m] 2000 NN, per IEC60947-4 Protection Class IP2X Single contactor cover — Contactor with frame terminal block — Auxiliary contact IP2X Protection against Accidental Contact — Resistance to Shock Resistance to Vibration Mechanically Linked Contacts IEC60947-5-1,AnnexL Mirror Contacts IEC60947-4 Annex F IEC60068-2 IEC60068-2 100-K…(on main device) 100-K…+100-KF… Standards Compliance and Certifications Standards Compliance Certifications IEC/EN 60947-1,-4-1,-5-1,-5-4 CE Marked UL 508 CCC cULus Listed (File No. E41850, Guide NLDX, NLDX7) CSA 22.2. No. 14 NF F 62-000 Meets the material restrictions for European Directive 2002/95/IEC-EU-RoHS Rockwell Automation Publication 100-TD013F-EN-P - November 2017 13 Life-Load Curves Figure 1 - AC-3, Switching of squirrel-cage motors while starting /AC-1, Non- or slightly inductive loads, resistance furnaces Contact Life (millions of operations) 10 1 100-K12 100-K09 0.1 100-K05 0.01 1 10 Rated current Ie AC-3 [A] (Dashed curves - - - - AC-1 only, open) Electrical life; Ue = 400…460V AC 14 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100 Figure 2 - AC-4, Stepping of squirrel-cage motors 10 100-K09; 100-K12 Contact Life (millions of operations) 100-K05 1 0.1 0.01 0.1 1 10 Rated current Ie AC-4 [A] Electrical life; Ue = 400…460V AC Rockwell Automation Publication 100-TD013F-EN-P - November 2017 15 Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. Figure 3 - 100-K Miniature Contactor with 193-K Overload Relay 78.7 (3-7/64) 49 (1-15/16) 44.9 (1-25/32) 35.2 (1-25/64) 54 (2-1/8) 56 (2-13/64) 49.2 (1-15/16) 50 (1-31/32) 108.2 (4-1/4) 4 (5/32) 35 (1-25/64) 36.9 (1-29/64) 63.5 (2-1/2) Figure 4 - Mounting Position 25° 25° 12 180° *) *) -Minimum distance to grounded parts or walls 16 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Accessories Auxiliary Contact Blocks Cat. No. Description Connection Diagrams 21 31 For Use With Pkg. Qty. Screw Type Terminals Spring Clamp Terminals 1 100-KFC02 100-KRFC02 100-K05…K12 1 100-KFC11 100-KRFC11 0 100-K05…K12 1 100-KFC20 100-KRFC20 0 4 100-K05…K12 1 100-KFC04 100-KRFC04 1 3 100-K05…K12 1 100-KFC13 100-KRFC13 3 1 100-K05…K12 1 100-KFC31 100-KRFC31 2 2 100-K05…K12 1 100-KFC22 100-KRFC22 4 0 100-K05…K12 1 100-KFC40 100-KRFC40 0 2 100/104-K, 700-K 1 100-KFA02E 100-KRFA02E 1 1 100/104-K, 700-K 1 100-KFA11E 100-KRFA11E 2 0 100/104-K, 700-K 1 100-KFA20E 100-KRFA20E 0 4 100/104-K, 700-K 1 100-KFA04E 100-KRFA04E 1 3 100/104-K, 700-K 1 100-KFA13E 100-KRFA13E 2 2 100/104-K, 700-K 1 100-KFA22Z 100-KRFA22Z 3 1 100/104-K, 700-K 1 100-KFA31Z 100-KRFA31Z 4 0 100/104-K, 700-K 1 100-KFA40E 100-KRFA40E N.O. N.C. 0 2 100-K05…K12 1 1 2 22 32 23 31 24 32 23 33 24 34 21 31 41 51 22 32 42 52 23 31 41 51 24 32 42 52 23 43 53 31 24 44 54 32 23 53 31 41 24 54 32 42 Front-Mounted Auxiliary Contacts Auxiliary contact blocks 2- and 4-pole versions Choice of contact configurations Snap on, no tools required Electronic-compatible bifurcated contacts for signals down to 15V/2 mA • Mirror Contact performance per IEC 60947-4-1 • • • • 23 33 43 53 24 34 44 54 51 61 52 62 53 61 54 62 53 63 54 64 51 61 71 81 52 62 72 82 53 61 71 81 54 62 72 82 53 83 61 71 54 84 62 72 53 73 83 61 54 74 84 62 53 63 73 83 54 64 74 84 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 17 Control Modules Connection Diagrams Description Mechanical Interlock • For interlocking of two adjacent contactors No added width to contactor assembly • Front mount plug-in type • Optional auxiliary contact blocks and suppressor modules mount onto the interlock 24…48V AC 110…280V AC RC Suppressor MOV Suppressor 12…55V AC, 12…77V DC 56…136V AC, 78…180V DC Cat. No. 100/104-K/-KR, 700-K/-KR 1 100-KMCH 1(1) 1(1) 100-KFSC50 100-KFSC280 1(1) 100-KFSC480 1(1) 1(1) 100-KFSV55 100-KFSV136 1(1) 100-KFSV277 1(1) 100-KFSD250 100/104-K/-KR, 700-K/-KR 137…277V AC, 181…250V DC Diode Suppressor Pkg. Qty. 100/104-K/-KR, 700-K/-KR 380…480V AC Surge Suppressor • Plug-in type • Limits surge voltage on coil drop-off For Use With 100/104-K/-KR, 700-K/-KR 12…250V DC (1) May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFSC50M. Timers Connection Diagrams Description On-Delay, 0.1…3 s Solid-State Timing Element • 110…250V AC or DC • Includes 35 mm Hat Rail adapter For Use With Cat. No. Pkg. Qty. 100-KT3S ~ S1 O/I 1 100/104-K, 700-K On-Delay, 1…30 s 10 2 100-KT30S K1 N Connecting Components Description ECO Connecting Module — 12 A • For DOL and reversing starters • Eco-starters mount on single DIN Rail (140M on DIN Rail) • Electrical and mechanical interconnection of 140M and 100-K contactors Power Wiring Kit • For Reversing and Star/Delta combinations. Star-point bridge not included. • Min. interruption time 50 ms Feeder Terminal for Compact Bus Bars • Max. current 34 A Three-Phase Compact Bus Bars • Max. current 34 A Connects: 140M-C circuit breakers with 100-K contactors 1 3 5 21 2 4 6 22 K1M 1 3 5 21 2 4 6 22 K2M Pkg. Qty. Cat. No. 140M-C to 100- K 1(1) 140M-C-PEK12 100-K 1 100-KPR 100-K 1 100-KWT 100-K 1 100-KW453 100-K 1 100-KW454 - (L2) Supply of compact bus bars For 1005K, 5…12 A contactors 45 mm spacing (3connections)(2) For 100-K, 5…12 A contactors 45 mm spacing (4connections)(2) (1) May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 140M-C-PEK12M. (2) Combinations possible. Example: For 6 contactor connections use one cat. no. 100-KW453 and one cat. no. 100-KW454. 18 For Use With Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Marking Systems Description Pkg. Qty. Cat. No. Label Sheet • 105 self-adhesive paper labels each, 6 x 17 mm 10 100-FMS Snap-In Marker Card 5 1492-M6X12 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 19 Notes: 20 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100-C/104-C, 100S-C/104S-C, 100Q-C Contactors Product Selection—100-C/104-C Contactors • • • • • • • • Compact sizes from 4…55 kW/5…75 Hp (9…97 A) Common accessories for all contactor sizes Front and side mounting of auxiliary contacts Electronic and pneumatic timing modules Space-saving coil-mounted control modules Reversible coil terminations (line or load side) All devices can be attached to 35 mm DIN mounting Rail Environmentally friendly materials 100-C Contactor 104-C Reversing Contactor The Bulletin 100-C/104-C IEC contactor family, along with a wide range of common accessories and Bulletin 193 solid-state overload relays, provides the most compact and flexible starter component system available. 3-Pole AC- and DC-operated Contactors Rated Operational Current Ie [A] 40 °C 230V Ratings for switching AC motors - AC-2, AC-3, AC-4 3-phase kW (50 Hz) Hp (60 Hz) 1-Phase 3-Phase 400/415V 500V 690V 115V 230V 200V 230V 460V Auxiliary Contacts Cat. No.(1) AC-3 AC-1 575V 9 32 3 4 4 4 1/2 1-1/12 2 2 5 7-1/12 12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 15 23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 30 65 10 15 15 15 2 5 7-1/2 10 20 25 37 65 11 18.5/20 20 18.5 3 5 10 10 25 30 43 85 13 22 25 22 3 7-1/2 10 15 30 30 55 85 15 30 30 30 5 10 15 20 40 40 60 100 18.5 32 37 32 5 10 15 20 40 50 72 100 22 40 45 40 5 15 20 25 50 60 85 100 25 45 55 45 7-1/2 15 25 30 60 60 97 130 30 55 55 55 10 20 30 30 75 75 N.O. 1 0 1 0 1 0 1 0 1 0 0 1 0 0 1 0 0 1 0 0 1 0 0 1 0 0 1 0 0 1 0 N.C. 0 1 0 1 0 1 0 1 0 1 0 0 1 0 0 1 0 0 1 0 0 1 0 0 1 0 0 1 0 0 1 100-C0910 100-C0901 100-C1210 100-C1201 100-C1610 100-C1601 100-C2310 100-C2301 100-C3000 100-C3010 100-C3700 100-C3701 100-C3710 100-C4300 100-C4310 100-C4301 100-C5500 100-C5510 100-C5501 100-C6000 100-C6010 100-C6001 100-C7200 100-C7210 100-C7201 100-C8500 100-C8510 100-C8501 100-C9700 100-C9710 100-C9701 (1) For screwlesss terminals on 100-C09…C16, add an “R” after the letter “C” in the catalog number. Example: Cat. No. 100-C0910 becomes 100-CR0910. The AC-1 rating for the 100-CR is limited to 25 A. Coil voltage code and terminal position—see page 24 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 21 4-Pole AC- and DC-Operated Contactors 40 °C Contact Configuration, Main Poles Ratings for switching AC motors - AC-2, AC-3 Rated Operational Current Ie [A] 3-phase kW (50 Hz)(2) Hp (60 Hz) 1-Phase 115V 230V Cat. No.(1) 3-Phase* 230V 460V 230V 400/415V 500V 690V 32 3 4 4 4 1/2 1-1/2 2 2 5 7-1/2 12 32 4 5.5 5.5 5.5 1/2 2 3 3 7-1/2 10 16 32 5.5 7.5 7.5 7.5 1 3 5 5 10 10 23 32 7.5 11 13 10 2 3 5 7-1/2 15 15 37 75 11 18.5/20 20 18.5 3 5 10 10 25 30 85 130 25 45 55 45 7-1/2 15 25 30 60 50 AC-3 AC-1 9 200V 575V N.O. 4 3 2 4 3 2 4 3 2 4 3 2 4 2 4 2 N.C. 0 1 2 0 1 2 0 1 2 0 1 2 0 2 0 2 100-C09400 100-C09300 100-C09200 100-C12400 100-C12300 100-C12200 100-C16400 100-C16300 100-C16200 100-C23400 100-C23300 100-C23200 100-C40400 100-C40200 100-C90400 100-C90200 (1) For screwlesss terminals on 100-C09…C16, add an “R” after the letter “C” in the catalog number. Example: Cat. No. 100-C0910 becomes 100-CR0910. The AC-1 rating for the 100-CR is limited to 25 A. (2) Three-phase ratings apply only to contactors with at least three N.O. power poles. Coil voltage code and terminal position— see page 24. 22 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Reversing AC- and DC-Operated Contactors 40 °C Auxiliary Contacts per Contactor Ratings for switching AC motors - AC-2, AC-3, AC-4 Rated Operational Current Ie [A] 3-phase kW (50 Hz) Hp (60 Hz) 1-Phase 115V 230V 1/2 1-1/2 1 2 1 3 2 3 Cat. No. 3-Phase 230V 460V 2 5 3 7-1/2 5 10 7-1/2 15 230V 400/415V 500V 690V 3 4 5.5 7.5 4 5.5 7.5 11 4 5.5 7.5 13 4 5.5 7.5 10 65 10 15 15 15 2 5 7-1/2 10 20 25 37 65 11 18.5/20 20 18.5 3 5 10 10 25 30 43 85 13 22 25 22 3 7.5 10 15 30 30 55 85 15 30 30 30 5 10 15 20 40 40 60 100 18.5 32 37 32 5 10 15 20 40 50 72 100 22 40 45 40 5 15 20 25 50 60 85 100 25 45 55 45 7-1/2 15 25 30 60 60 97 130 30 55 55 55 10 15 30 30 75 75 AC-3 9 12 16 23 AC-1 32 32 32 32 30 200V 2 3 5 5 575V 7-1/2 10 15 20 N.O. 1 1 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 N.C. (1) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 104-C0922 104-C1222 104-C1622 104-C2322 104-C3002 104-C3022 104-C3702 104-C3722 104-C4302 104-C4322 104-C5502 104-C5522 104-C6002 104-C6022 104-C7202 104-C7222 104-C8502 104-C8522 104-C9702 104-C9722 (1) The N.C. auxiliary contact is supplied as part of the mechanical/electrical interlock. Coil voltage code and terminal position— see page 24. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 23 Coil Voltage Codes The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 60 Hz: Cat. No. 100-C0910 becomes Cat. No.100-C09D10. AC Voltages [V] 12 24 32 36 42 48 100 50 Hz 60 Hz 50/60 Hz R Q — K J KJ V — — W V — X — — Y X KY KP — KP 240 277 347 380 T A KA — T — — I — — E — 100… 110 — KP — 110 120 127 200 D — KD P D — S — — KG — KG 200… 220 L KG KL(1) 440 480 B N KB — B — — H — 208… 240 — L — 500 550 600 M — — C — — — C — 208 (1) Not available on 100/104-C90 or -C97 contactors. AC Voltages [V] 50 Hz 60 Hz 50/60 Hz 220… 230 F — KL(1) 230 — — KF 230… 240 VA — — 380… 400 N — — 400 — — KN 400… 415 G — — (1) Not available on 100/104-C90 or -C97 contactors. DC Voltages [V] Electronic with 100-C09…C55 Integrated Diode 100-C60…C97 with Integrated Diode 9 12 24 24 36 36…48 48 48…72 60 64 — EW — EY — — — EQ EJ QJ(1) DR DQ DJ — DW — DY — DZ DB 72 80 110 110…125 115 125 220 220…250 230 250 — — — ED — — — EA — — DG DE DD — DP DS DA — DF DT (1) “QJ” coil has faster dropout time (16…21 ms). DC Voltages [V] Electronic with 100-C09…C55 Integrated Diode 100-C60…C97 with Integrated Diode Coil Terminal Position All contactors are delivered with the coil terminals located on the line side. For load side coil terminations, insert a “U” prior to the coil voltage code. Ordering example: Cat. No. 100-C09UD10. Cat. No.100-C0910 Line Side 24 Cat. No.100-C09U10 Load Side Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Assignment of Contacts Table valid for: AC / DC = 0.85…1.1 x Us, Tamb = -25 °C…+60 °C, normal position (horizontal rail mounting) Device Combinations in Accordance with IEC 60947-1 / -4-1 Auxiliary Contact Blocks Circuit Diagram 100-C Contactors (AC and DC Control) 100-C30_00 100-C37_00 100-C43_00 100-C09_400 100-C55_00 100-C12_400 100-C09_01 100-C60_00 100-C16_400 100-C12_01 100-C72_00 100-C23_400 100-C16_01 100-C85_00 100-C40_400 100-C23_01 100-C97_00 100-C90_400 100-C09_10 100-C12_10 100-C16_10 100-C23_10 Control A1 1 3 5 13 K1 A1 1 3 5 A2 2 4 6 14 A1 1 21 A2 2 4 6 22 32 100-SB01 A1 1 5 3 5 100-C09_300 100-C12_300 100-C16_300 100-C23_300 7 K1 A2 2 Side Mounting 21 3 K1 K1 4 6 A1 1 3 5 R7 4 6 8 A1 1 R3 R5 7 A2 R4 R6 8 K1 K1 A2 2 100-C09_200 100-C12_200 100-C16_200 100-C23_200 100-C40_200 100-C90_200 A2 2 4 6 R8 2 (1) AC/DC 10 + 01 = 11 01 + 01 = 02 (3) 00 + 01 = 01 00 + 01 = 01 00 + 01 = 01 00 + 01 = 01 AC/DC 10 + 10 = 20 (3) 01 + 10 = 11 00 + 10 = 10 00 + 10 = 10 00 + 10 = 10 00 + 10 = 10 AC/DC 10 + 02 = 12 (3) — 00 + 02 = 02 00 + 02 = 02 00 + 02 = 02 00 + 02 = 02 AC/DC 10 + 11 = 21 (3) 01 + 11 = 12 (3) 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11 AC/DC 10 + 20 = 30 (3) 01 + 20 = 21 (3) 00 + 20 = 20 00 + 20 = 20 00 + 20 = 20 00 + 20 = 20 AC/DC 10 + L11 = L21 (3) 01 + L11 = L12 (3) 00 + L11 = L11 00 + L11 = L11 00 + L11 = L11 00 + L11 = L11 22 31 13 44 100-SB10 14 43 11 21 32 42 100-SB02 12 22 31 41 13 21 32 44 100-SB11 14 22 31 43 13 23 34 44 100-SB20 14 24 33 43 17 25 36 48 100-SBL11 (2) 18 26 35 47 (1) Up to 8 auxiliary contacts possible: contactor + front mounted (AC max. 4 N.C. / DC max. 4 N.C.), side mounted (AC max. 2 N.O. / DC max. 2 N.O. and max. 2 N.C.). (2) Early make and/or late break. (3) Double numbering: because of double numbering only left-side mounting is recommended. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 25 Device Combinations in Accordance with IEC 60947-1 / -4-1 Auxiliary Contact Blocks Circuit Diagram 100-C Contactors (AC and DC Control) 100-C30_00 100-C37_00 100-C43_00 100-C09_400 100-C55_00 100-C12_400 100-C09_01 100-C60_00 100-C16_400 100-C12_01 100-C72_00 100-C23_400 100-C16_01 100-C85_00 100-C40_400 100-C23_01 100-C97_00 100-C90_400 100-C09_10 100-C12_10 100-C16_10 100-C23_10 Control A1 1 3 5 13 K1 A1 1 3 5 A2 2 4 6 14 A1 1 21 3 A2 2 4 6 22 A1 1 5 K1 K1 3 5 100-C09_300 100-C12_300 100-C16_300 100-C23_300 7 K1 A2 2 4 6 A1 1 3 5 R7 4 6 8 A1 1 R3 R5 7 A2 R4 R6 8 K1 K1 A2 2 100-C09_200 100-C12_200 100-C16_200 100-C23_200 100-C40_200 100-C90_200 A2 2 4 6 R8 2 Front Mounting (1) 100-FA02, 100-FAB02 51 61 100-FA11, 100-FAB11 53 61 AC/DC 10 + 02 = 12 01 + 02 = 03 00 + 02 = 02 00 + 02 = 02 00 + 02 = 02 00 + 02 = 02 AC/DC 10 + 11 = 21 01 + 11 = 12 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11 AC/DC — — 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11 00 + 11 = 11 AC/DC 10 + 11 = 21 — — — — — AC/DC 10 + 20 = 30 01 + 20 = 21 00 + 20 = 20 00 + 20 = 20 00 + 20 = 20 00 + 20 = 20 AC/DC — — 00 + L11 = L11 00 + L11 = L11 00 + L11 = L11 00 + L11 = L11 AC/DC 10 + 22 = 32 01 + 22 = 23 00 + 22 = 22 00 + 22 = 22 00 + 22 = 22 00 + 22 = 22 AC/DC — — 00 + 22 = 22 00 + 22 = 22 00 + 22 = 22 00 + 22 = 22 AC/DC 10 + 22 = 32 — — — — — AC/DC 10 + 31 = 41 01 + 31 = 32 00 + 31 = 31 00 + 31 = 31 00 + 31 = 31 00 + 31 = 31 AC/DC 10 + 40 = 50 01 + 40 = 41 00 + 40 = 40 00 + 40 = 40 00 + 40 = 40 00 + 40 = 40 AC/DC 10 + L22 = L32 01 + L22 = L23 00 + L22 = L22 00 + L22 = L22 00 + L22 = L22 00 + L22 = L22 AC/DC 10 + 04 = 14 01 + 04 = 05 00 + 04 = 04 00 + 04 = 04 00 + 04 = 04 00 + 04 = 04 52 62 54 62 100-FB11, 100-FBB11 13 21 100-FC11, 100-FCB11 23 31 100-FA20, 100-FAB20 53 63 100-FBL11 (2) 14 22 24 32 54 64 17 25 18 26 100-FA22, 100-FAB22 53 61 71 83 100-FB22, 100-FBB22 13 21 31 43 100-FC22, 100-FCB22 21 31 43 53 100-FA31, 100-FAB31 53 61 73 83 100-FA40, 100-FAB40 53 63 73 83 54 62 72 84 14 22 32 44 22 32 44 54 54 62 74 84 54 64 74 84 100-FAL22 (2) 53 61 75 87 54 62 76 88 100-FA04, 100-FAB04 26 51 61 71 81 52 62 72 82 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Auxiliary Contact Blocks Circuit Diagram 100-C Contactors (AC and DC Control) 100-C30_00 100-C37_00 100-C43_00 100-C09_400 100-C55_00 100-C12_400 100-C09_01 100-C60_00 100-C16_400 100-C12_01 100-C72_00 100-C23_400 100-C16_01 100-C85_00 100-C40_400 100-C23_01 100-C97_00 100-C90_400 100-C09_10 100-C12_10 100-C16_10 100-C23_10 Control A1 1 3 5 13 K1 A2 2 100-FA13, 100-FAB13 53 61 71 81 A1 1 3 5 4 6 14 A1 1 21 3 A2 2 4 6 22 A1 1 5 K1 K1 3 5 100-C09_300 100-C12_300 100-C16_300 100-C23_300 7 K1 A2 2 4 6 A1 1 3 5 R7 4 6 8 A1 1 R3 R5 7 A2 R4 R6 8 K1 K1 A2 2 100-C09_200 100-C12_200 100-C16_200 100-C23_200 100-C40_200 100-C90_200 A2 2 4 6 R8 2 AC/DC 10 + 13 = 23 01 + 13 = 14 00 + 13 = 13 00 + 13 = 13 00 + 13 = 13 00 + 13 = 13 AC/DC 10 + 02 = 12 01 + 02 = 03 00 + 02 = 02 00 + 02 = 02 00 + 02 = 02 00 + 02 = 02 AC/DC 10 + 20 = 30 01 + 20 = 21 00 + 20 = 20 00 + 20 = 20 00 + 20 = 20 00 + 20 = 20 AC/DC 10 + 31 = 41 01 + 31 = 32 00 + 31 = 31 00 + 31 = 31 00 + 31 = 31 00 + 31 = 31 54 62 72 82 100-FB02, 100-FBB02 11 21 100-FB20, 100-FBB20 13 23 100-FC31, 100-FCB31 23 31 43 53 12 22 14 24 24 32 44 54 (1) Up to 8 auxiliary contacts possible: contactor + front mounted (AC max. 4 N.C. / DC max. 4 N.C.), side mounted (AC max. 2 N.O. / DC max. 2 N.O. and max. 2 N.C.). (2) Early make and/or late break. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 27 Product Selection—100S-C/104S-C Safety Contactors • Mechanically linked N.C. auxiliary contacts • Front-mounted auxiliary contacts – Gold bifurcated – Permanently fixed – Protective cover to prevent manual operation – Red contact housing for easy identification – “Mechanically Linked” or “Mirror Contact” symbol • AC and DC operating coils • SUVA Third-Party certification 100S-C Safety Contactor 104S-C Reversing Safety Contactor Bulletin 100S-C/104S-C safety contactors provide mechanically linked positively guided contacts, required in feedback circuits of modern safety applications. The mechanically linked N.C. auxiliary contacts will not change state when a power pole welds. In addition, the gold-plated bifurcated auxiliary contacts are ideally suited for low-energy applications or feedback control circuits with multiple series-connected N.C. auxiliary contacts. 3-Pole AC- and DC-operated Contactors Ratings for switching AC motors - AC-2, AC-3, AC-4 3-phase kW (50 Hz) Hp (60 Hz) Rated Operational Current Ie [A] 40 °C 230V 400/415V 500V AC-3 AC-1 9 32 3 4 4 12 32 4 5.5 16 32 5.5 23 32 30 1-Phase 690V Auxiliary Contacts Cat. No.(1) (2) 3-Phase 115V 230V 200V 230V 460V 575V 4 1/2 1-1/2 2 2 5 7-1/2 5.5 5.5 1/2 2 3 3 7-1/2 10 7.5 7.5 7.5 1 3 5 5 10 15 7.5 11 13 10 2 3 5 7-1/2 15 15 65 10 15 15 15 2 5 7-1/2 10 20 25 37 65 11 18.5/20 20 18.5 3 5 10 10 25 30 43 85 13 22 25 22 3 7-1/2 10 15 30 30 55 85 15 30 30 30 5 10 15 20 40 40 60 100 18.5 32 37 32 5 10 15 20 40 50 72 100 22 40 45 40 5 15 20 25 50 60 85 100 25 45 55 45 7-1/2 15 25 30 60 60 97 130 30 55 55 55 10 15 30 30 75 75 N.O. 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 N.C. 5 4 5 4 5 4 5 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 100S-C0905BC 100S-C0914BC 100S-C1205BC 100S-C1214BC 100S-C1605BC 100S-C1614BC 100S-C2305BC 100S-C2314BC 100S-C3004BC 100S-C3014BC 100S-C3704BC 100S-C3714BC 100S-C4304BC 100S-C4314BC 100S-C5504BC 100S-C5514BC 100S-C6004BC(3) 100S-C6014BC(3) 100S-C7204BC(3) 100S-C7214BC(3) 100S-C8504BC(3) 100S-C8514BC(3) 100S-C9704BC(3) 100S-C9714BC(3) (1) For other contact configurations and full product details, please contact your local Rockwell Automation sales office or Allen-Bradley distributor. (2) If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 100S-C09 05BC becomes Cat. No. 100S- C09 05C. (3) Front- and side-mount auxiliary contacts on Cat. Nos. 100S-C60…C97 conform to mirror contact performance only. Coil voltage code and terminal position— see page 31. 28 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 4-Pole AC- and DC-operated Contactors Ratings for Switching AC Motors AC-2, AC-3, AC-4 Hp (60 Hz) 3-Phase kW (50 Hz)(3) 1-Phase 3-Phase(3) Ie [A] AC-3 AC-1 230V 400V/ 415V 500V 690V 9 32 3 4 4 12 32 4 5.5 16 32 5.5 23 32 7.5 Contact Configuration Main Pole Auxiliary Contacts Cat. No.(1) (2) 115V 230V 200V 230V 460V 575V 4 1/2 1-1/2 2 2 5 7-1/2 5.5 5.5 1/2 2 3 3 7-1/2 10 7.5 7.5 7.5 1 3 5 5 10 15 11 13 10 2 3 5 7-1/2 15 15 N.O. 3 4 3 4 3 4 3 N.C. 1 0 1 0 1 0 1 N.O. 0 0 0 0 0 0 0 N.C. 4 4 4 4 4 4 4 100S-C09404BC 100S-C09304BC 100S-C12404BC 100S-C12304BC 100S-C16404BC 100S-C16304BC 100S-C23404BC 100S-C23304BC (1) For other contact configurations and full product details, please contact your local Rockwell Automation sales office or Allen-Bradley distributor. (2) If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 100S-C09404BC becomes Cat. No. 100S- C09 404C. (3) Three-phase ratings only apply to contactors with at least three N.O. power poles. Coil voltage code and terminal position— see page 31. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 29 Reversing AC- and DC-Operated Contactors • 3 Main Contacts • Includes Mechanical/Electrical Interlock • Includes Reversing Power Wiring Rated Operational Current Ie [A] 40 °C 3-phase kW (50 Hz) 230V 400/ 415V 500V AC-3 AC-1 9 32 3 4 4 12 32 4 5.5 16 32 5.5 23 32 30 (1) (2) (3) (4) Ratings for switching AC motors - AC-2, AC-3, AC-4 Hp (60 Hz) Auxiliary Contacts 1-Phase 690V Cat. No.(1) (2) 3-Phase 115V 230V 200V 230V 460V 575V 4 1/2 1-1/2 2 2 5 7-1/2 5.5 5.5 1/2 2 3 3 7-1/2 10 7.5 7.5 7.5 1 3 5 5 10 15 7.5 11 13 10 2 3 5 7-1/2 15 15 65 10 15 15 15 2 5 7-1/2 10 20 25 37 65 11 18.5/20 20 18.5 3 5 10 10 25 30 43 85 13 22 25 22 3 7-1/2 10 15 30 30 55 85 15 30 30 30 5 10 15 20 40 40 60 100 18.5 32 37 32 5 10 15 20 40 50 72 100 22 40 45 40 5 15 20 25 50 60 85 100 25 45 55 45 7-1/2 15 25 30 60 60 97 130 30 55 55 55 10 15 30 30 75 75 N.C.(3) 6 5 6 5 6 5 6 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 104S-C09012BC 104S-C09210BC 104S-C12012BC 104S-C12210BC 104S-C16012BC 104S-C16210BC 104S-C23012BC 104S-C23210BC 104S-C30010BC 104S-C30210BC 104S-C37010BC 104S-C37210BC 104S-C43010BC 104S-C43210BC 104S-C55010BC 104S-C55210BC 104S-C60010BC(4) 104S-C60210BC(4) 104S-C72010BC(4) 104S-C72210BC(4) 104S-C85010BC(4) 104S-C85210BC(4) 104S-C97010BC(4) 1 5 104S-C97210BC(4) For other contact configurations and full product details, please contact your local Rockwell Automation sales office or Allen-Bradley distributor. If standard cross-stamped front-mount auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 104S-C0905BC becomes Cat. No. 104S- C09 05C. One of the N.C. auxiliary contacts is supplied as part of the mechanical/electrical interlock. Front- and side-mount auxiliary contacts on Cat. Nos. 104S-C60…C97 conform to mirror contact performance only. Coil voltage code and terminal position— see page 31. 30 N.O. 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Coil Voltage Codes The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 60 Hz: Cat. No. 100S-C0905BC becomes Cat. No.100S-C09D05BC. AC Voltages [V] 12 24 32 36 42 48 100 50 Hz 60 Hz 50/60 Hz R Q — K J KJ V — — W V — X — — Y X KY KP — KP 240 277 347 380 T A KA — T — — I — — E — 100… 110 — KP — 110 120 127 200 D — KD P D — S — — KG — KG 200… 220 L KG KL(1) 440 480 B N KB — B — — H — 208… 240 — L — 500 550 600 M — — C — — — C — 208 (1) Not available on 100S/104S-C97 contactors. AC Voltages [V] 50 Hz 60 Hz 50/60 Hz 220… 230 F — KL(1) 230 — — KF 230… 240 VA — — 380… 400 N — — 400 — — KN 400… 415 G — — (1) Not available on 100S/104S-C97 contactors. DC Voltages [V] Electronic with 100S-C09…C55 Integrated Diode 100S-C60…C97 with Integrated Diode 9 12 24 24 36 36…48 48 48…72 60 64 — EW — EY — — — EQ EJ QJ(1) DR DQ DJ — DW — DY — DZ DB 72 80 110 110…125 115 125 220 220…250 230 250 — — — ED — — — EA — — DG DE DD — DP DS DA — DF DT (1) “QJ” coil has faster dropout time (16…21 ms). DC Voltages [V] Electronic with 100S-C09…C55 Integrated Diode 100S-C60…C97 with Integrated Diode Coil Terminal Position All contactors are delivered with the coil terminals located on the line side. For load side coil terminations, insert a “U” prior to the coil voltage code. Ordering example: Cat. No. 100S-C09UD05BC. Cat. No.100S-C0905CLine Side Cat. No.100S-C09U05CLoad Side Rockwell Automation Publication 100-TD013F-EN-P - November 2017 31 Assignment of Contacts Safety Contactors with 3 Main Contacts and Standard Front-Mount Auxiliary Contacts A1 51 61 71 81 51 61 71 81 53 61 71 83 52 62 72 82 52 62 72 82 54 62 72 84 1 3 5 K1 1 3 5 13 A2 2 6 4 A1 A2 22 2 4 6 14 100S-C0914C…C2314C 5 21 A2 2 4 6 22 100S-C0923C…C2323C 11 21 31 41 12 22 32 42 14 22 32 44 12 22 32 42 1 3 A1 5 2 4 1 3 5 A1 1 3 5 _3 A2 2 4 6 _4 K1 A2 6 100S-C3004C…C5504C 2 4 6 100S-C3022C…C5522C 100S-C3014C…C5514C 11 21 31 41 13 21 31 43 11 21 31 41 12 22 32 42 14 22 32 44 12 22 32 42 1 3 5 K1 A1 1 3 5 K1 A2 3 13 21 31 43 K1 A1 1 11 21 31 41 K1 A2 A1 K1 K1 100S-C0905C…C2305C 2 4 6 100S-C6004C…C9704C 32 A1 21 A1 1 3 5 _3 A2 2 4 6 _4 K1 A2 2 4 6 100S-C6022C…C9722C Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100S-C6014C…C9714C Safety Contactors with 4 Main Contacts and Standard Front-Mount Auxiliary Contacts A1 11 21 31 41 11 21 31 41 12 22 32 42 12 22 32 42 1 3 5 7 K1 A1 1 3 5 R7 A2 2 4 6 R8 K1 A2 2 4 6 8 100S-C09⊗404C…C23⊗404C 100S-C09⊗304C…C23⊗304C 13 21 31 43 13 21 31 43 14 22 32 44 14 22 32 44 A1 1 3 5 7 K1 A1 1 3 5 R7 A2 4 6 R8 K1 A2 2 4 6 8 100S-C09⊗422C…C23⊗422C 2 100S-C09⊗322C…C23⊗322C Rockwell Automation Publication 100-TD013F-EN-P - November 2017 33 Safety Reversing Contactors with 3 Main Contacts and Standard Front-Mount Auxiliary Contacts A1 51 61 71 81 21 51 61 71 81 51 61 71 81 21 51 61 71 81 52 62 72 82 22 52 62 72 82 52 62 72 82 22 52 62 72 82 13 21 1 3 5 21 21 K1 A1 1 3 5 2 6 4 22 A2 22 1 3 5 K1 K2 A2 A1 21 2 6 4 A2 22 2 6 4 14 22 A2 2 4 6 14 11 21 31 41 21 11 21 31 41 12 22 32 42 22 12 22 32 42 12 22 32 42 22 12 22 32 42 1 3 5 21 2 4 6 A1 22 1 3 A1 5 1 3 5 _3 21 K1 A2 2 4 1 3 5 _3 A2 2 4 6 _4 K2 A2 6 A1 2 4 6 _4 22 104S-C30210C…C55210C 11 21 31 41 21 11 21 31 41 11 21 31 41 21 11 21 31 41 12 22 32 42 22 12 22 32 42 12 22 32 42 22 12 22 32 42 1 3 5 21 A1 1 3 2 4 6 22 A1 5 1 3 5 _3 21 A2 2 104S-C60010C…C97010C 4 6 A1 1 3 5 _3 A2 2 4 6 _4 K1 K1 K1 K1 34 13 11 21 31 41 104S-C30010C…C55010C A2 5 21 K2 A1 3 11 21 31 41 K1 A2 1 104S-C09210C…C23210C 104S-C09012C…C23012C A1 A1 K2 A2 2 4 6 _4 22 104S-C60210C…C97210C Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Safety Contactors with 3 Main Contacts and Bifurcated Front-Mount Auxiliary Contacts A1 51 61 71 81 51 61 71 81 53 61 71 83 52 62 72 82 52 62 72 82 54 62 72 84 1 3 5 21 K1 A1 1 3 5 13 A2 2 6 4 A1 A2 22 2 4 6 14 100S-C0914BC…C2314BC 21 A2 2 4 6 22 100S-C0923BC…C2323BC 11 21 31 41 12 22 32 42 14 22 32 44 12 22 32 42 1 3 5 2 4 A1 1 3 5 A1 1 3 5 _3 A2 2 4 6 _4 K1 A2 6 100S-C3004BC…C5504BC 2 4 6 100S-C3022BC…C5522BC 100S-C3014BC…C5514BC 11 21 31 41 13 21 31 43 11 21 31 41 12 22 32 42 14 22 32 44 12 22 32 42 1 3 5 K1 A1 1 3 5 K1 A2 5 13 21 31 43 K1 A1 3 11 21 31 41 K1 A2 1 K1 K1 100S-C0905BC…C2305BC A1 2 4 6 100S-C6004BC…C9704BC A1 1 3 5 _3 A2 2 4 6 _4 K1 A2 2 4 6 100S-C6022BC…C9722BC Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100S-C6014BC…C9714BC 35 Safety Contactors with 4 Main Contacts and Bifurcated Front-Mount Auxiliary Contacts A1 11 21 31 41 11 21 31 41 12 22 32 42 12 22 32 42 1 3 5 7 K1 A2 2 4 6 8 100S-C09⊗404BC…C23⊗404BC 1 3 5 R7 A2 2 4 6 R8 100S-C09⊗304BC…C23⊗304BC 13 21 31 43 13 21 31 43 14 22 32 44 14 22 32 44 A1 1 3 5 7 K1 A1 1 3 5 R7 A2 4 6 R8 K1 A2 2 4 6 8 100S-C09⊗422BC…C23⊗422BC 36 A1 K1 2 100S-C09⊗322BC…C23⊗322BC Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Safety Reversing Contactors with 3 Main Contacts and Bifurcated Front-Mount Auxiliary Contacts 51 61 71 81 21 51 61 71 81 51 61 71 81 21 51 61 71 81 52 62 72 82 22 52 62 72 82 52 62 72 82 22 52 62 72 82 13 21 A1 1 3 5 A2 2 4 6 21 21 22 22 K1 A1 1 3 5 4 6 21 K2 A1 1 3 5 K1 A2 2 22 A2 2 6 4 13 14 22 A2 2 4 6 14 21 11 21 31 41 11 21 31 41 21 11 21 31 41 12 22 32 42 22 12 22 32 42 12 22 32 42 22 12 22 32 42 1 3 5 21 A1 1 3 2 4 6 22 A1 5 1 3 5 _3 21 K1 A2 2 4 A2 6 A1 1 3 5 _3 A2 2 4 6 _4 K2 2 4 104S-C30010BC…C55010BC 6 _4 22 104S-C30210BC…C55210BC 11 21 31 41 21 11 21 31 41 11 21 31 41 21 11 21 31 41 12 22 32 42 22 12 22 32 42 12 22 32 42 22 12 22 32 42 1 3 5 21 A1 1 3 2 4 6 22 A1 5 1 3 5 _3 21 A2 2 104S-C60010BC…C97010BC 4 6 A1 1 3 5 _3 A2 2 4 6 _4 K1 K1 K1 K1 A2 5 104S-C09210BC…C23210BC K2 A1 3 11 21 31 41 K1 A2 1 K2 104S-C09012BC…C23012BC A1 A1 A2 2 4 6 _4 22 104S-C60210BC…C97210BC Rockwell Automation Publication 100-TD013F-EN-P - November 2017 37 Product Selection—100Q-C Capacitor-switching Contactors • • • • • • Compact sizes Limits high inrush currents AC and DC coil control Reversible coil terminals Panel or 35 mm DIN Rail mounting Environmentally friendly materials The Bulletin 100Q-C Capacitor-Switching contactors are designed for switching banks of capacitors. The unique design uses front-mounted resistor elements that limit the severely high inrush currents seen in these applications. This reduces stress to the contactors and the capacitors, as well as allowing a more compact and economical design without the use of air-core reactors. For Applications per IEC 60947-4 (AC-6b) 1-Phase 50 Hz (kVar) 400V 415V 230V 240V 5 5 8.5 9 10.5 15 8.5 8.5 15 8 8.5 14 14.5 17.5 24 14 14 25 1-Phase 50 Hz (kVar) 400V 415V 500V Ratings for Switching Capacitor Banks @ 40 °C 3-Phase 50 Hz (kVar) 690V 230V 240V 400V 415V 500V 500V 690V 15.5 18.5 25 25 30 40 500V 690V Ratings for Switching Capacitor Banks @ 40 °C 3-Phase 50 Hz (kVar) 690V 230V 240V 400V 415V 230V 240V 5 5 8.5 9 10.5 15 8.5 8.5 15 15.5 18.5 25 8 8.5 14 14.5 17.5 24 14 14 25 25 30 40 Aux. Contacts N.O. N.C. 1 1 2 0 1 1 2 0 Aux. Contacts N.O. N.C. 1 1 2 0 1 1 2 0 Cat. No. 100Q-C1611 100Q-C1620 100Q-C3711 100Q-C3720 Cat. No. 100Q-C1611 100Q-C1620 100Q-C3711 100Q-C3720 For Applications per UL/CSA 1-Phase 60 Hz (kVar) 115V 230V 200V Ratings for Switching Capacitor Banks 3-Phase 60 Hz (kVar) 230V 460V 600V 2.2 4.5 6.5 7.5 15 18.5 3.6 7.5 11 12.5 20 25 Aux. Contacts N.O. 1 2 1 2 Coil voltage code — see page 39. 38 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 N.C. 1 0 1 0 Cat. No. 100Q-C1611 100Q-C1620 100Q-C3711 100Q-C3720 Coil Voltage Codes The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 60 Hz: Cat. No. 100Q-C1611 becomes Cat. No.100Q-C16D11. AC Voltages [V] 12 24 32 36 42 48 100 50 Hz 60 Hz 50/60 Hz R Q — K J KJ V — — W V — X — — Y X KY KP — KP 230 230… 240 VA — — 240 277 347 380 T A KA — T — — I — — E — DC Voltages [V] Electronic with Integrated Diode 9 — 12 EQ 24 EJ 36 — DC Voltages [V] Electronic with Integrated Diode 80 — 110 — 110…125 ED 115 — AC Voltages [V] 220… 230 50 Hz F — 60 Hz KL 50/60 Hz — — KF 100… 110 — KP — 110 120 127 200 208 KG — KG 200… 220 L KG KL — H — 208… 240 — L — D — KD P D — S — — 380… 400 N — — 400 — — KN 400… 415 G — — 440 480 500 550 600 B N KB — B — M — — C — — — C — 48 — 60 — 64 — 72 — 125 — 220 — 220…250 EA 230 — 250 — Maximum Operational Rates • 100Q-C16 • 100Q-C37 200 operations/hour 100 operations/hour Rockwell Automation Publication 100-TD013F-EN-P - November 2017 39 Specifications Conventional Electronic — EI 09 X X Rated Operational Current, Ie ≤500V 690V 230V 240V 400V 415V 500V 690V [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] 32 32 13 13 22 23 28 38 Rated Operational Current, Ie ≤500V 690V 230V 240V 400V 415V 500V 690V [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] 32 32 13 13 22 23 28 38 Rated Operational Current, Ie 230V 240V 400V 415V 500V 690V 230V 240V 400V 415V 500V 690V [A] [A] [A] [A] [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] 12 12 9 9 7 5 3 3 4 4 4 4 General Purpose Current (enclosed) 115V 230V Rated power (enclosed) 1-phase 115V 230V 200V 230V 460V 575V Rated power (enclosed) 3-phase 200V 230V 460V 575V [A] [A] [A] [Hp] [Hp] [A] [A] [A] [A] [Hp] [Hp] [Hp] [Hp] 25 9.8 10 0.5 1.5 7.8 6.8 7.6 9 2 2 5 7.5 Coil Type: 100/104-C, 100S/104S-C 16 23 30 37 40*200 40*400 43 55 X X X X X X X X X X X X X X X X AC-1 Active Power Load (50 Hz); Ambient temperature 40 °C 32 32 32(40)(1) 65 65 75 75 85 85 32 32 32(40)(1) 65 65 75 75 85 85 13 13 13 26 26 30 30 34 34 13 13 13 27 27 31 31 35 35 22 22 22 45 45 52 52 59 59 23 23 23 47 47 54 54 61 61 28 28 28 56 56 65 65 74 74 38 38 38 78 78 90 90 102 102 AC-1 Active Power Load (50 Hz); Ambient temperature 60 °C 32 32 32 65 65 60 60 75 75 32 32 32 65 65 60 60 75 75 13 13 13 26 26 24 24 25 25 13 13 13 27 27 25 25 26 26 22 22 22 45 45 42 42 44 44 23 23 23 47 47 43 43 45 45 28 28 28 56 56 52 52 55 55 38 38 38 78 78 72 72 75 75 Switching of 3-phase Motors; (50 Hz) Ambient temperature 60 °C, AC-2, AC-3 15 20 26.5 35 38 38 38 44 56 15 20 26.5 35 38 38 38 44 56 12 16 23 30 37 37 37 43 55 12 16 23 30 37 37 37 43 55 10 14 20 25 30 29 30 38 44 7 9 12 18 21 9 21 25 25 4 5.5 7.5 10 11 11 11 13 15 4 5.5 7.5 10 11 11 11 13 15 5.5 7.5 11 15 18.5 18.5 18.5 22 30 5.5 7.5 11 15 20 20 20 22 30 5.5 7.5 13 15 20 18.5 20 25 30 5.5 7.5 10 15 18.5 7.5 18.5 22 22 Load Carrying Capacity per UL/CSA 25 30 30 55 60 60 60 75 75 9.8 16 24 24 34 34 34 34 56 12 17 17 28 28 28 28 40 50 0.5 1 2 2 3 3 3 3 5 2 3 3 5 5 5 5 7.5 10 11 17.5 17.5 25.3 32.2 32.2 32.2 32.2 48.3 9.6 15.2 22 28 28 28 28 42 54 11 14 21 27 34 34 34 40 52 11 17 17 27 32 17 32 32 41 3 5 5 7.5 10 10 10 10 15 3 5 7.5 10 10 10 10 15 20 7.5 10 15 20 25 25 25 30 40 10 15 15 25 30 15 30 30 40 12 X X (1) Values in () with increased cross-section and cable lug 40 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 60 X — 72 X — 85 X — 90*200 90*400 X X — — 97 X — 100 100 40 42 69 72 87 120 100 100 40 42 69 72 87 120 100 100 40 42 69 72 87 120 130 130 52 54 90 93 113 155 130 130 52 54 90 93 113 155 130 130 52 54 90 93 113 155 100 100 40 42 69 72 87 120 100 100 40 42 69 72 87 120 100 100 40 42 69 72 87 120 110 110 44 46 76 79 95 131 110 110 44 46 76 79 95 131 110 110 44 46 76 79 95 131 62 62 60 60 55 34 18.5 18.5 32 32 37 32 72 72 72 72 67 42 22 22 40 40 45 40 85 85 85 85 80 49 25 25 45 45 55 45 85 85 85 85 80 22 25 25 45 45 55 18.5 85 85 85 85 80 49 25 25 45 45 55 45 96 95 97 97 78 57 30 30 55 55 55 55 90 56 50 5 10 48.3 54 52 52 15 20 40 50 90 56 68 5 15 62.1 68 65 62 20 25 50 60 100 80 68 7.5 15 78.2 80 77 62 25 30 60 60 125 80 68 7.5 15 78.2 80 65 22 25 30 50 20 130 80 68 7.5 15 78.2 80 77 52 25 30 60 50 120 100 88 10 20 92 80 96 77 30 30 75 75 Coil Type: Conventional Electronic — EI 230V 240V 400V 415V 500V 690V 230V 240V 400V 415V 500V 690V [A] [A] [A] [A] [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] 230V 240V 400/415V 500V 690V 230V (1) 240V (1) 400V (1) 415V (1) 500V (1) 690V (1) [A] [A] [A] [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] Ops/hour 200V 230V 460V 575V [Hp] [Hp] [Hp] [Hp] 200V 230V 460V 575V 200V 230V 460V 575V [A] [A] [A] [A] [Hp] [Hp] [Hp] [Hp] Max. switching frequency 100/104-C, 100S/104S-C 09 12 16 23 30 37 43 X X X X X X X X X X X X X X Switching of 3-phase Motors, (50 Hz); Ambient temperature 60 °C, AC-4 12 15 20 26.5 35 38 44 12 15 20 26.5 35 38 44 9 12 16 23 30 37 43 9 12 16 23 30 37 43 7 10 14 20 25 30 38 5 7 9 12 18 21 25 3 4 5.5 7.5 10 11 13 3 4 5.5 7.5 10 11 13 4 5.5 7.5 11 15 18.5 22 4 5.5 7.5 11 15 20 22 4 5.5 7.5 13 15 20 25 4 5.5 7.5 10 15 18.5 22 AC-4 at approximately 200,000 operations 4.3 6.6 9 9 12 14 16.5 4.3 6.6 9 9 12 14 16.5 4.3 6.6 9 9 12 14 16.5 4.3 6.6 9 9 12 14 16.5 4.3 6.6 9 9 12 14 16.5 0.75 1.5 2.2 2.2 3 3.7 4 0.75 1.5 2.2 2.2 3 4 4 1.8 3 4 4 5.5 6.3 7.5 1.8 3 4 4 5.5 6.3 7.5 2.2 3.7 5.5 5.5 7.5 7.5 10 3 5.5 7.5 7.5 10 11 15 250 250 220 200 200 200 200 Wye-Delta (60 Hz) 5 5 7½ 7½ 10 15 20 5 7½ 10 10 15 20 25 10 15 20 25 30 40 50 10 15 20 25 30 40 50 UL/CSA Elevator Duty 7.8 11.0 11.0 17.5 25.3 25.3 32.2 6.8 9.6 15.2 15.2 22.0 28.0 28.0 7.6 11.0 04.0 21.0 27.0 27.0 34.0 6.1 9.0 11.0 17.0 22.0 27.0 32.0 2 3 3 5 7-1/2 7-1/2 10 2 3 5 5 7-1/2 10 10 5 7-1/2 10 15 20 20 25 5 7-1/2 10 15 20 25 30 55 X X 60 X — 72 X — 85 X — 97 X — 56 56 55 55 44 25 15 15 30 30 30 22 62 62 60 60 55 34 18.5 18.5 32 32 37 32 72 72 72 72 67 42 22 22 40 40 45 40 85 85 85 85 80 49 25 25 45 45 55 45 96 95 97 97 78 57 30 30 55 55 55 55 22 22 22 22 22 5.5 5.5 11 11 11 18.5 200 25.5 25.5 25.5 25.5 25.5 6.3 7.5 13 13 15 22 120 31 31 31 31 31 7.5 7.5 15 17 20 25 120 38 38 38 38 38 11 11 20 20 25 32 120 44 44 44 44 44 11 11 22 22 30 37 120 25 30 60 60 30 40 75 75 40 50 100 100 50 60 125 125 50 60 125 125 TBD TBD TBD TBD TBD TBD TBD TBD 32.2 42.0 40.0 41.0 10 15 30 40 48.3 54.0 52.0 52.0 15 20 40 50 62.1 68.0 65.0 62.0 20 25 50 60 TBD TBD TBD TBD TBD TBD TBD TBD (1) Power ratings at 50 Hz: Preferred values according to IEC 60072-1 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 41 Coil Type: Conventional Electronic — EI ≤ 230V ≤ 240V 400V 415V 500V 690V 230V (1) 240V (1) 400V (1) 415V (1) 500V (1) 690V (1) Inrush Current Rated transformer current n= 30 n=20 n=15 [A] [A] [A] [A] [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] 09 X X 21 21 16 16 12 8.6 5.5 5.5 7.5 7.5 7.5 7.5 100/104-C, 100S/104S-C 16 23 30 37 43 X X X X X X X X X X Star-Delta Starting (50 Hz) 26 35 46 61 66 76 26 35 46 61 66 76 21 28 40 52 64 74 21 28 40 52 64 74 17 24 35 43 52 66 12 16 21 31 36 43 7.5 10 13 17 20 22 7.5 10 13 18.5 20 22 10 13 20 25 32 40 11 15 22 25 32 40 11 15 22 25 32 45 10 13 18.5 25 32 40 Switching of Power Transformers, AC-6a (50 Hz) 12 X X 55 X X 60 X — 72 X — 85 X — 97 X — 96 96 95.3 95.3 76.2 55.4 30 30 45 45 45 45 107 107 104 104 95 59 32 32 55 55 63 55 125 125 125 125 116 73 37 40 63 63 80 63 147 47 147 47 139 85 45 50 80 80 90 80 166 165 168 168 135 99 50 50 90 90 90 90 23 23 23 23 23 23 9.2 10 16 17 20 27 34.5 46 23 23 23 23 23 23 9.2 10 16 17 20 27 34.5 46 40.8 40.8 40.8 40.8 40.8 40.8 16 17 28 29 35 49 61.3 82 40.8 40.8 40.8 40.8 40.8 40.8 16 17 28 29 35 49 61.3 82 40.8 40.8 40.8 40.8 40.8 40.8 16 17 28 29 35 49 61.3 82 48.5 48.5 48.5 48.5 48.5 48.5 19.3 20.2 33.6 34.9 42 58 72.8 97 23 8.0 8.3 9.6 19.1 23.9 26.3 23 8 8.3 9.6 19.1 23.9 26.3 40.8 14.1 14.7 17.0 33.9 42.4 46.6 40.8 14.4 14.7 17.0 33.9 42.4 46.6 40.8 14.4 14.7 17.0 33.9 42.4 46.6 48.5 16.8 17.5 20.2 40.3 50.4 55.4 34.5 12.0 12.4 14.3 28.7 35.9 39.4 34.5 12 12.4 14.3 28.7 35.9 39.4 61.3 21.2 22.1 25.5 51.0 63.7 70.1 61.3 21.2 22.1 25.5 51.0 63.7 70.1 61.3 21.2 22.1 25.5 51.0 63.7 70.1 72.8 25.2 26.2 30.3 60.5 75.7 83.2 =n ≤ 230V ≤ 240V ≤ 400V ≤ 415V ≤ 500V ≤ 690V 230V 240V 400V 415V 500V 690V ≤ 690V ≤ 690V [A] [A] [A] [A] [A] [A] [kVA] [kVA] [kVA] [kVA] [kVA] [kVA] [A] [A] 10.9 10.9 10.9 10.9 10.9 10.9 4.3 4.5 7.5 7.8 9.4 13 16.3 22 n=30 200V 208V 240V 480V 600V 660V [A] [kVA] [kVA] [kVA] [kVA] [kVA] [kVA] 10.9 3.8 3.9 4.5 9.1 11.3 12.5 n=20 200V 208V 240V 480V 600V 660V [A] [kVA] [kVA] [kVA] [kVA] [kVA] [kVA] 16.3 5.6 5.9 6.8 13.6 16.9 18.6 10.9 10.9 10.9 20 20 10.9 10.9 10.9 20 20 10.9 10.9 10.9 20 20 10.9 10.9 10.9 20 20 10.9 10.9 10.9 20 20 10.9 10.9 10.9 20 20 4.3 4.3 4.3 8 8 4.5 4.5 4.5 8.3 8.3 7.5 7.5 7.5 14 14 7.8 7.8 7.8 14 14 9.4 9.4 9.4 17 17 13 13 13 24 24 16.3 16.3 16.3 30 30 22 22 22 40 40 60 Hz Peak Inrush/peak rated transformer current 10.9 10.9 10.9 20 20 3.8 3.8 3.8 6.9 6.9 3.9 3.9 3.9 7.2 7.2 4.5 4.5 4.5 8.3 8.3 9.1 9.1 9.1 16.6 16.6 11.3 11.3 11.3 20.8 20.8 12.5 12.5 12.5 22.9 22.9 60 Hz Peak Inrush/peak rated transformer current 16.3 16.3 16.3 30 30 5.6 5.6 5.6 10.4 10.4 5.9 5.9 5.9 10.8 10.8 6.8 6.8 6.8 12.5 12.5 13.6 13.6 13.6 24.9 24.9 16.9 16.9 16.9 31.2 31.2 18.6 18.6 18.6 34.3 34.3 (1) Power ratings at 50 Hz: Preferred values according to IEC 60072-1 42 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Conventional Electronic — EI 09 X X n=15 200V 208V 240V 480V 600V 660V 22 7.5 7.8 9.0 18.1 22.6 24.9 Coil Type: Coil Type: Single capacitor 40°C Single capacitor 60 °C Group capacitors 40°C Group capacitors 60 °C 60 Hz Single Capacitor — 40 °C 60 Hz Group Capacitors — 40 °C [A] [kVA] [kVA] [kVA] [kVA] [kVA] [kVA] Conventional Electronic — EI 09 X X 12 X X [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] 8 8 8 8 8 8 8 8 8 8 8 8 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 8 8 8 8 8 8 8 8 8 8 8 8 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 230V 240V 400V 415V 500V 690V 230V 240V 400V 415V 500V 690V 230V 240V 400V 415V 500V 690V 230V 240V 400V 415V 500V 690V 200V 230V 460V 600V 200V 230V 460V 600V 100/104-C, 100S/104S-C 12 16 23 30 37 43 X X X X X X X X X X X X 60 Hz Peak Inrush/peak rated transformer current 22 22 22 40 40 46 7.5 7.5 7.5 13.9 13.9 15.9 7.8 7.8 7.8 14.4 14.4 16.6 9.0 9.0 9.0 16.6 16.6 19.1 18.1 18.1 18.1 33.3 33.3 38.2 22.6 22.6 22.6 41.6 41.6 47.8 24.9 24.9 24.9 45.7 45.7 52.6 100/104-C, 100S/104S-C 16 23 30 37 40*200 40*400 43 55 X X X X X X X X X X X X X X X X Switching of 3-phase Capacitors, AC-6b (50 Hz)(1) 8.5 9 14 14 — — 24 24 8.5 9 14 14 — — 25 25 10 12.5 20 24 — — 35 35 10 12.5 20 25 — — 35 35 10 12.5 20 25 — — 35 35 10 12.5 20 25 — — 35 35 8.5 9 12.5 12.5 — — 18 18 8.5 9 12.5 12.5 — — 18 18 10 12.5 20 21.5 — — 30 30 10 12.5 20 22 — — 30 30 10 12.5 20 25 — — 30 30 10 12.5 20 25 — — 30 30 8 9 12.5 14 — — 20 20 8 9 12.5 14 — — 20 20 8 10 15 20 — — 25 25 8 10 15 20 — — 25 25 8 10 15 20 — — 25 25 8 10 15 20 — — 25 25 8 9 12.5 12.5 — — 18 18 8 9 12.5 12.5 — — 18 18 8 10 15 20 — — 25 25 8 10 15 20 — — 25 25 8 10 15 20 — — 25 25 8 10 15 20 — — 25 25 8 9 12.5 14 — — 20 20 8 9 12.5 14 — — 20 20 8 10 15 20 — — 25 25 8 10 15 20 — — 25 25 8 9 12.5 12.5 — — 18 18 8 9 12.5 12.5 — — 18 18 8 10 15 20 — — 25 25 8 10 15 20 — — 25 25 55 X X 60 X — 72 X — 85 X — 97 X — 46 15.9 16.6 19.1 38.2 47.8 52.6 82 28.4 29.5 34.1 68.2 85.2 93.7 82 28.4 29.5 34.1 68.2 85.2 93.7 82 28.4 29.5 34.1 68.2 85.2 93.7 97 33.6 34.9 40.3 80.6 100.8 110.9 60 X — 72 X — 85 X — 28 29 48 50 50 50 28 29 42 42 42 42 28 29 40 40 40 40 28 29 40 40 40 40 28 29 40 40 28 29 40 40 28 29 48 50 55 55 28 29 48 50 50 50 28 29 48 50 50 50 28 29 48 50 50 50 28 29 50 50 28 29 50 50 28 29 48 50 60 60 28 29 48 50 55 55 28 29 48 50 50 50 28 29 48 50 50 50 28 29 50 50 28 29 50 50 90*200 90*400 97 X X X — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 28 29 48 50 60 60 28 29 48 50 55 55 28 29 48 50 50 50 28 29 48 50 50 50 28 29 50 50 28 29 50 50 (1) Inductance of leads between capacitors in parallel: min. 6 H (100-C09…C30 contactors: min 30 H) Rockwell Automation Publication 100-TD013F-EN-P - November 2017 43 Coil Type: 09 X X 12 X X 16 X X 23 X X 100/104-C, 100S/104S-C 30 37 40*200 40*400 43 55 X X X X X X X X X X X X Switching of Lamps [A] [A] 22.5 22.5 25 25 28 28 29 29 40.5 37 45 41 65 54 65 54 77 57 77 57 81 77 85 81 90 90 115 95 115 95 115 100 [F] [F] [F] 1000 500 200 1000 500 200 1000 500 200 1000 500 200 2700 1350 540 2700 1350 540 — — — — — — 3200 1600 640 3200 1600 640 4000 2000 800 4000 2000 800 4700 2350 940 — — — — — — 4700 2350 940 [A] 12 16 18 22 30 37 18 25 43 51 60 70 76 60 75 90 — — — — — — — — — — — — — — — — — — — — — — — — 100 100 80 — — — — — — 115 115 90 Conventional Electronic — EI Gas discharge lamps AC-5a, 40 °C open enclosed Individually compensated: Max. capacitance at expected 10 kA Short-circuit current of 20 kA 50 kA 230/ Filament AC-5b 240V AC-7a 230V 400V 440V [A] [A] [A] AC-7b 230V 400V 440V [A] [A] [A] 400V 500V AC-8a 690V - automatic reset of overload release 400V AC-8b 500V 690V [A] [A] [A] 72 X — 85 X — Switching of Low Inductive Loads in Home Appliances and Similar Applications per IEC 61095 (50 Hz) 32 32 32 32 45 45 — — 63 63 — — 32 32 32 32 45 45 — — 63 63 — — 32 32 32 32 45 45 — — 63 63 — — Switching of Motor Load for Home Appliances (50 Hz) 10.5 14 19 23 30 — — — — — — — 9 12 16 20 30 — — — — — — — 7.5 10 13.5 18 27 — — — — — — — Switching of Hermetically Sealed Cooling Compressor Motors - manual reset of overload release (50 Hz) 12 16 22 32 38 45 — — 63 63 72 85 12 16 22 32 38 45 — — 63 63 72 85 8 10 14 20 28 35 — — 42 42 56 67 5.5 5.5 5.5 7 7 7 90*200 90*400 X X — — 97 X — 9.3 9.3 9.3 12 12 12 13 14 — 13 14 — 13 14 — Switching of DC Loads — — — 16 16 16 16 16 16 24 24 24 30 30 30 35 35 35 — — — — — — 35 35 35 Non-inductive or slightly inductive loads or resistance furnaces DC-1, 60 °C [A] 25 25 32 24V 48/60V [A] 20 20 20 110V 1 pole [A] 6 6 6 220V [A] 1.5 1.5 1.5 440V [A] 0.4 0.4 0.4 [A] 25 25 32 24V 48/60V [A] 25 25 32 110V [A] 25 25 32 2 poles in series 220V [A] 8 8 8 440V [A] 1 1 1 [A] 25 25 32 24V 48/60V [A] 25 25 32 110V [A] 20 20 25 3 poles in series 220V [A] 6 6 6 440V [A] 0.6 0.6 0.6 32 20 6 1.5 0.4 32 32 32 10 1 32 32 25 10 0.6 45 25 8 1.5 0.4 45 45 45 10 1 45 45 30 15 0.6 45 25 10 1.5 0.4 45 45 45 10 1 — — — — — 50 30 9 1.5 0.5 50 50 50 10 1 63 50 35 20 0.6 50 30 9 1.5 0.5 50 50 50 10 1 63 50 35 20 0.6 70 40 11 2 0.5 70 70 70 15 1.5 90 70 70 25 0.6 80 40 11 2 0.5 80 80 80 15 1.5 90 90 90 80 5 80 40 11 2 0.5 80 80 80 15 1.5 100 100 100 80 5 80 40 11 1.8 0.5 80 80 80 15 1.5 — — — — — 80 40 11 1.8 0.5 80 80 80 15 1.5 100 100 100 80 5 80 40 11 2 0.5 80 80 80 15 1.5 100 100 100 80 5 44 [A] [A] [A] 60 X — 45 25 8 1.5 0.4 45 45 45 10 1 45 45 30 15 0.6 45 25 10 1.5 0.4 45 45 45 10 1 — — — — — Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100/104-C, 100S/104S-C 30 37 40*200 40*400 43 55 Conventional X X X X X X Coil Type: Electronic — EI X X X X X X Switching of DC Loads, Continued Series-wound Motors, Starting, reverse current braking, reversing, stepping DC-3, 60 °C [A] 25 25 32 32 45 45 — — 63 63 24V 48/60V [A] 25 25 32 32 45 45 — — 50 50 110V [A] 20 20 25 25 30 30 — — 35 35 3 poles in series 220V [A] 6 6 6 10 15 15 — — 20 20 440V [A] 0.6 0.6 0.6 0.6 0.6 0.6 — — 0.6 0.6 Series-wound Motors, Starting, reverse current braking, reversing, stepping DC-5, 60 °C [A] 25 25 32 32 45 45 — — 63 63 24V 48/60V [A] 25 25 32 32 45 45 — — 50 50 110V [A] 20 20 25 25 30 30 — — 35 35 3 poles in series 220V [A] 6 6 6 10 15 15 — — 20 20 440V [A] 0.6 0.6 0.6 0.6 0.6 0.6 — — 0.6 0.6 Short Time Withstand [A] 170 170 170 215 300 304 304 304 375 375 10 s ICW, , 60 °C Resistance and Power Dissipation [m] 2.7 2.7 2.7 2 2 2 2 1.5 1.5 1 Main current circuit resistance Power dissipation by all circuits at [W] 0.66 1.2 2.1 3.2 5.4 8.2 11.3 8.4 8.3 9.1 Ie AC-3/400V AC [W] 3.4 3.9 4.8 6.3 8.5 11.3 8.8 9.5 11.6 12.4 control DC Total power dissipation control [W] — — — — — — — — — — At Ie AC-3/400V (conv.) DC control [W] 2.4 2.9 3.8 4.9 7.1 9.9 8 8.7 10.8 11.6 (elect.) Lifespan [Million ops.] 13 13 13 13 13 13 10 10 12 12 Mechanical AC control Mechanical DC control [Million ops.] 13 13 13 13 13 13 10 10 13 13 Electrical AC-3 (400 V) [Million ops.] 1.3 1.3 1.3 1.3 1.3 1.3 — — 1 0.8 Weight Non[kg 0.39 0.39 0.39 0.39 0.48 0.49 0.63 0.63 0.51 0.51 Rev. (lbs)] (0.86) (0.86) (0.86) (0.86) (1.06) (1.08) (1.39) (1.39) (1.12) (1.12) AC [kg 0.85 0.85 0.85 0.85 1.08 1.08 1.15 1.15 Rev. — — (lbs)] (1.89) (1.89) (1.89) (1.89) (2.39) (2.39) (2.54) (2.54) Non[kg 0.6 — — — — — — — — — Rev. (lbs)] (1.32) DC [kg 1.27 Rev. — — — — — — — — — (lbs)] (2.81) Non[kg 0.40 0.40 0.40(0.8 0.40 0.49 0.49 0.57 0.57 0.57 — Rev. (lbs)] (0.88) (0.88) 8) (0.88) (1.08) (1.08) (1.25) (1.25) (1.25) DC (Electronic-EQ, EJ) [kg 0.87 0.87 0.87(1.9 0.87 1.08 1.08 1.27 Rev. — — — (lbs)] (1.91) (1.91) 1) (1.91) (2.39) (2.39) (2.79) [kg Non0.43 0.43 0.43(0.9 0.43 0.52 0.52 0.60 0.60 0.60 — (lbs)] Rev. (0.95) (0.95) 5) (0.95) (1.14) (1.14) (1.32) (1.32) (1.32) DC (Electronic- EW, EY, ED, EA) [kg 0.93 0.93 0.93(2.0 0.93 1.14 1.14 1.33 Rev. — — — (lbs)] (2.05) (2.05) 5) (2.05) (2.51) (2.51) (2.93) 09 X X 12 X X 16 X X 23 X X 60 X — 72 X — 85 X — 90 70 70 25 0.6 90 70 70 25 0.6 100 80 80 30 0.6 — — — — — — — — — — 100 80 80 30 0.6 90 70 70 25 0.6 90 70 70 25 0.6 100 80 80 30 0.6 — — — — — — — — — — 100 80 80 30 0.6 700 700 700 700 700 840 0.9 0.9 0.9 0.8 0.7 0.6 9.7 14 19.5 11.6 20.2 17 14.2 18.5 24 20.6 29.2 26 13.7 18 23.5 16.6 25.2 22 — — — — — — 6 6 1 6 6 1 6 6 1 6 6 — 6 6 — 6 6 1 1.45 (3.20) 3.14 (6.92) 1.47 (3.24) 3.22 (7.1) 0.57 (1.25) 1.27 (2.79) 0.60 (1.32) 1.33 (2.93) 1.45 (3.20) 3.14 (6.92) 1.47 (3.24) 3.22 (7.1) 1.45 (3.20) 3.14 (6.92) 1.47 (3.24) 3.22 (7.1) — — — — — — — — — — — — — — — — — — — — — — — — — — — — Rockwell Automation Publication 100-TD013F-EN-P - November 2017 90*200 90*400 X X — — 97 X — 1.45 (3.20) 3.14 (6.92) 1.47 (3.24) 3.22 (7.1) 45 Coil Type: Conventional Electronic — EI 09 X X 12 X X 16 X X 23 X X 30 X X 37 X X (1) Recommended torque Cross section per UL/CSA Recommended torque [mm2] [mm2] [mm2] [mm2] [N•m] [AWG] [lb-in] 1…4 1…4 1.5…6 1.5…6 1.5…2.0 16…10 13.3…17.7 2.5…10 2.5…10 2.5…16 2.5…16 2.5…3.5 14…4 22…31 2.5…16 2.5…10 2.5…25 2.5…16 2.5…3.5 14…6 14…4 22…31 (1) Pozidriv No. 2 / Blade No. 3 screw (2) Pozidriv No. 2 / Blade No. 4 screw (3) Hexagonal socket screw 46 60 X — 72 X — 85 X — (2) Conductor Cross Sections - Main Contacts Terminal type 1 conductor 2 conductors 1 conductor 2 conductors 100/104-C, 100S/104S-C 40 43 55 X X X X X X Rockwell Automation Publication 100-TD013F-EN-P - November 2017 90 X — (3) 2.5…35 2.5…25 2.5…50 2.5…35 4.5…6 14…1 40…53 97 X — Short-Circuit Coordination Data See http://www.rockwellautomation.com/global/support/global-sccr.page? for complete short-circuit current ratings. 100/104-C, 100S/104S-C 09 12 16 23 30 37 40*200 40*400 43 55 60 72 85 90*200 90*400 97 Conventional X X X X X X X X X X X X X X X X Coil Type: Electronic - EI X X X X X X X X X X — — — — — — Short Circuit Coordination (Max. Fuse or Circuit Breaker Rating) Per IEC 60947-4-1 (contactor and fuses only) DIN Fuses- gG, gL 50 kA Available Fault Current Type"1"(690V) [A] 50 50 50 80 125 125 160 160 160 160 250 250 250 250 250 250 Type"2"(400V) [A] 25 35 35 40 80 80 63 80 100 100 160 160 160 160 100 200 Type"2"(690V) [A] 25 35 35 40 80 80 63 80 100 100 160 160 160 160 100 200 BS88Fuses 65kA Available Fault Current Type"1"(415V) [A] 25 32 40 50 63 80 — — 80 TBD 100 160 160 — — TBD Type"2"(415V) [A] 20 25 32 50 63 80 — — 80 TBD 100 125 160 — — TBD Per UL 508 and CSA 22.2 No. 14 (contactor and fuses or circuit breaker only) UL Class K5 and RK5 Fuses 5 kA Available Fault Current UL Listed Combination (600V) [A] 35 40 70 90 110 125 125 125 150 200 200 — — — — — UL Class K5 and RK5 Fuses 10 kA Available Fault Current UL Listed Combination (600V) [A] — — — — — — — — — — — 250 300 300 300 350 UL Class CC and CSA HRCI-MISC Fuses 100 kA Available Fault Current UL verified combination to [A] 20(1) 20 30 40 — — — — — — — — — — — — IEC60947-4-1 "Type2" 100 kA Available Fault Current UL Class J and CSA HRCI-J Fuses UL verified combination to [A] 20(1) 20 30 40 50 50 — — 70 TBD 80 100 150 — — 175 IEC60947-4-1 "Type2" 5 kA Available Fault Current UL Inverse-Time Circuit Breaker UL Listed Combination (480V) [A] 30 30 50 50 125 125 — — 125 150 250 — — — — — UL Listed Combination (600V) [A] — — — — 125 125 — — 125 150 250 — — — — — UL Inverse-Time Circuit Breaker 10 kA Available Fault Current UL Listed Combination (600V) [A] — — — — — — — — — — — 250 250 — — 250 UL Inverse-Time Circuit Breaker 18 kA Available Fault Current UL Listed Combination (600V) [A] — — — — — — — — — — — — — — — — UL Inverse-Time Circuit Breaker 25 kA Available Fault Current UL Listed Combination [A] 30(2) 30(2) 30(2) 30(2) 50(3) 50(3) — — 50(3) — 110 110 110 — — — (600Y/347V) 25 kA Available Fault Current UL Inverse-Time Circuit Breaker UL Listed Combination (600V) [A] — — — — 100(4) 100(4) — — 100(4) 125 200(4) 225(4) 225(4) — — 225(4) UL Inverse-Time Circuit Breaker 50 kA Available Fault Current UL Listed Combination (480V) [A] — — — — 50(3) 50(3) — — 50(3) — — — — — — — UL Inverse-Time Circuit Breaker 65 kA Available Fault Current UL Listed Combination (480Y/277V) [A] 30(2) 30(2) 30(2) 30(2) — — — — — — — — — — — — UL Inverse-Time Circuit Breaker 65 kA Available Fault Current UL Listed Combination (480V) [A] — — — — 100(4) 100(4) — — 100(4) 125 200(4) 225(4) 225(4) — — 225(4) (1) (2) (3) (4) 15 A max. fuse for Type 2 coordination. Ratings apply when used with Bulletin 140U-D circuit breakers only. Minimum enclosure size 12-3/8 x 7-5/8 s 7-1/4 inches Minimum enclosure size 20 x 12 x 8 inches with two latches. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 47 Coil Data Coil Type: 50 Hz, 60 Hz, 50/60 Hz DC (conventional) DC (electronic—EQ, EJ, EW, QJ) DC (electronic—EY) DC (electronic—ED) DC (electronic—EA) 09 X X Conventional Electronic - EI pick-up dropout pick-up dropout pick-up dropout pick-up dropout pick-up dropout pick-up dropout [x Us] [x Us] [x Us] [x Us] [x Us] [x Us] [x Us] [x Us] [x Us] [x Us] [x Us] [x Us] pick-up [VA] hold-in [VA/W] pick-up [W] DC (conventional) hold-in [W] DC (electronic—EQ, EJ, pick-up (avg/peak) [W] QJ) hold-in [W] pick-up (avg/peak) [W] DC (electronic—EY, EW) hold-in [W] pick-up (avg/peak) [W] DC (electronic—ED) hold-in [W] pick-up (avg/peak) [W] DC (electronic—EA) hold-in [W] 50 Hz, 60 Hz, 50/60 Hz AC With RC module DC (conventional) With integrated diode With external diode DC (electronic—EQ, EJ) DC (electronic—EW, EY, ED, EA) DC (electronic—QJ) closing delay opening delay closing delay opening delay closing delay opening delay opening delay closing delay opening delay Max. Ripple min. OFF time closing delay opening delay Max. Ripple min. OFF time closing delay opening delay Max. Ripple min. OFF time 12 X X [ms] [ms] [ms] [ms] [ms] [ms] [ms] [ms] [ms] [ms] [ms] [ms] [ms] [ms] [ms] [ms] 75 9.5/2.7 — — 15…30 10…60 10…60 — — — — 100/104-C, 100S/104S-C 30 37 40*200 40*400 43 55 X X X X X X X X X X X X Operating Limits 0.85…1.1 0.85….1.1 0.3…0.6 0.3…0.6 — — — — 0.7…1.25 0.3…0.4 0.8…1.25 0.3…0.4 0.7…1.12(1) 0.3…0.4 0.8…1.1 0.3…0.4 Coil Consumption 105 135 12.3/3.1 13.3/3.3 — — — — 10/17 16/25 1.7 2.5 10/17 16/25 1.9 2.7 12/19 16/26 2.1 2.8 14/22 18/29 3.0 4.0 Operating Times 15…30 15…30 15…30 10…60 10…60 10…60 10…60 10…60 10…60 10…60 — — — 50…80 — — — 7…15 — — — 17…23 — — — — 80…125 20…50 — 20…50 — ±15% — 50 — 20…50 — 23…33 — ±15% — 50 — 20…50 — 16…21 — ±15% — 50 — 16 X X 23 X X (1) 0.7…1.25 at 110V DC 48 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 60 X — 72 X — 85 X — 90*200 90*400 X X — — 97 X — 0.85….1.1 0.3…0.6 0.8…1.1 0.1…0.6 — — — — — — — — 235 19.6/5 200 4 — — — — — — — — 400/240 24/9 325 5 — — — — — — — — 20…40 10…60 10…60 20…40 — 220V 20…35 — — — — — — — — — — — — — 20…40 20…40 20…40 15…25 20…25 20…25 — 220V 20…35 — — — — — — — — — — — — — Auxiliary Contacts, Auxiliary Contact Blocks, and Pneumatic Timers Internal AC-12 Ith AC-15 at rated voltage of DC-12 L/R < 1 ms resistive loads at DC-14L/R <15 ms inductive loads with economy resistor in series at DC-13 switching electromagnets at [A] Switching of AC Loads 20 20 10 10 10 10 10 6 6 2.5 1 Switching of DC Loads 12 9 3.5 0.55 0.2 9 5 2 0.4 0.16 5 3 1.2 0.6 0.3 Fuse gG 20 [A] 20 at 40 °C at 60 °C 24V 42/48V 120V 230V 240V 400V 415V 500V 690V [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] 24V DC 48V DC 110V DC 220V DC 440V DC 24V DC 48V DC 110V DC 220V DC 440V DC 24V DC 48V DC 110V DC 220V DC 440V DC [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] Short-circuit protection with no welding of contacts per IEC 60947-5-1 between load and auxiliary circuit 320V 17V/10mA Load Carrying Capacity per UL/CSA Protective Separation per IEC 60947-1, Annex N Min. switching capacity according to IEC 60947-5-4 Rated voltage Continuous rating Switching capacity Rated voltage Switching capacity AC 40 °C AC DC DC [V] [A] [A] [V] [A] Front mounted Front mounted (Bifurcated) Side-mounted 10 6 6 6 6 5.5 5 3 3 1.6 1 10 6 3 3 3 3 3 2 2 1.2 0.7 10 6 6 6 6 5.5 5 3 3 1.6 1 12 9 3.5 0.55 0.2 9 5 2 0.4 0.16 5 3 1.2 0.6 0.15 6 3.2 1 0.5 0.2 2 1.6 0.3 0.12 0.05 2.5 1.5 0.6 0.3 0.15 6 3.2 1 0.5 0.2 2 1.6 0.3 0.12 0.05 5 2.5 0.68 0.32 0.15 10 10 10 10 10 10 between load and auxiliary circuit 440V 17V/5mA 5V/3mA 17V/10mA 10 10 max.600 10 10 A600 max.600 P600 Q600 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Q600 49 General Attribute Value Rated Isolation Voltage Ui IEC UL,CSA Rated Impulse Voltage Withstand Uimp [V] [V] [kV] AC 50/60 Hz DC Insulation Class of the Coil Rated coil frequency Ambient Temperature Storage Operation at rated voltage at 70 °C Climatic Withstand Max. Altitude of Installation Site [V] [V] 690 600 6 Rated Voltage Ue 115, 200, 230, 240, 400, 415, 460, 500, 575, 690 24, 48, 110, 220, 440 Class F per IEC 60085, UL Class 105 AC 50/60Hz, DC [°C] [°C] -55…+80 -25…+60 15% current reduction against 60 °C values IEC 60068-2-1/-2/-30 2000 NN, per IEC60947-1 100-C09…C23: IP2X from all directions 100-C30…C55: IP2X from front with front (upper) terminal wired 100-C60…C97: IP2X from front with front (upper) terminal wired (min. wire size 16 mm2 or #6 AWG) — — IP2X Finger- and back-of-hand proof per VDE0106, part100 IEC60068-2-27 IEC60068-2-6 100-/100S-C09…C55+100-FA/-FB/-FC, (except L11, L22),100-/100S-C09…C55+ 100-FAB/-FBB/-FCB 100-/100S-C09…C97+100-FA/-FB/-FC, (except L11, L22),100-/100S-C09…C97+ 100-SA/SB,100-/100S-C09…C97+100-FAB/-FBB/-FCB [m] Protection Class Single contactor cover Contactor with frame terminal block Auxiliary contact Protection against Accidental Contact Resistance to Shock Resistance to Vibration Mechanically Linked Contacts IEC60947-5-1,Annex L Mirror Contacts IEC60947-4 Annex F Standards Compliance and Certifications 100-C IEC Contactors Standards Compliance Certifications EN/IEC 60947-4-1, 60947-5-1 CE Marked IEC 60947 Type “2” Coordination CCC CSA 22.2. No. 14 cULus Listed (File No. E3125; Guide NLDX, NLDX7) UL 508 Meets the material restrictions for European Directive 2002/95/IEC-EU-RoHS 100S-C IEC Safety Contactors Standards Compliance Certifications EN50205 CE Marked CSA C22.2 No. 14 SUVA Third-Party Certified UL 508 cULus Listed (File No. E3125; Guide NLDX, NLDX7) EN/IEC 60947-4 IEC 60947-4-1 Annex F — Mirror Contacts IEC 60947-5-1 Annex L — Mechanically Linked Contacts Meets the material restrictions for European Directive 2002/95/IEC-EU-RoHS 50 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100Q-C Capacitor-switching Contactors Standards Compliance Certifications IEC 60947-4 CE Marked CSA C22.2 No. 14 cULus Listed (File No. E 41850, Guide NLDX, NLDX7) UL 508 Meets the material restrictions for European Directive 2002/95/IEC-EU-RoHS Life-Load Curves Bulletin 100-C/104-C IEC contactors are designed for superior performance in a wide variety of applications. When selecting IEC products, the user must give consideration to the specific load, utilization category, and required electrical life of the application. The life-load curves shown here are based on Rockwell Automation tests according to the requirements defined in IEC 60947-4-1. Since contact life in application is dependent on environmental conditions and duty cycle, actual application contact life may vary from that indicated by the curves shown here. To find the contactor’s estimated electrical life, follow these guidelines: 1. Identify the appropriate utilization category from Table 1. 2. Choose the graph for the utilization category selected. 3. Locate the intersection of the life-load curve for the appropriate contactor with the application’s operational current (Ie) found on the horizontal axis. 4. Read the estimated contact life along the vertical axis. Contact Life for Mixed Utilization Categories AC-3 and AC-4: In many applications, the utilization category cannot be defined as either purely AC-3 or AC-4. In those applications, the electrical life of the contactor can be estimated from the following equation: Lmixed = Lac3/[1 + Pac4*(Lac3/Lac4 – 1)], where: Lmixed = Approximate contact life in operations for a mixed AC-3/AC-4 utilization category application Lac3 = Approximate contact life in operations for a pure AC-3 utilization category (from the AC-3 life-load curves) Lac4 = Approximate contact life in operations for a pure AC-4 utilization category (from the AC-4 life-load curves) Pac4 = Percentage of AC-4 operations Rockwell Automation Publication 100-TD013F-EN-P - November 2017 51 Table 1 - Utilization Category Determination Test Conditions Resistance Furnaces: Non inductive or slightly inductive loads Slip-ring motors: Starting and reversing Squirrel-cage motors: Starting and stopping of running motors Squirrel-cage motors: Starting, plugging(1) , inching(2) Solenoids: Contactors, valves and lifting magnets AC-1 AC-2 AC-3 AC-4 AC-15 Ie < 17 A Ie > 17 A Ie < 17 A Ie > 17 A I/Ie Making U/Ue cos Ic/Ie Breaking Ur/Ue cos 1 1 0.95 1 1 0.95 2.5 1 0.65 2.5 1 0.65 6 6 6 6 1 1 1 1 0.65 0.35 0.65 0.35 1 1 6 6 0.17 0.17 1 1 0.65 0.35 0.65 0.35 10 1 0.7 1 1 0.4 (1) Plugging is understood as stopping or reversing the motor rapidly by reversing motor primary connections while the motor is running. (2) Inching (jogging) is understood as energizing a motor once or repeatedly for short periods to obtain small movements of the driven mechanism. Ie Rated operational current I Making Current Ic Breaking Current U Off-load voltage Ue Rated voltage Ur Recovery voltage Operating cycles C97 / C90 C72 C85 C60 C43 C30 C40 C37 C23 C16 10E+06 C12 C09 Figure 5 - AC-1, 40 °C Non- or slightly inductive loads, resistance furnaces; Ue = 230…690V 01E+06 C90 10E+04 1 10 100 Rated operating current Ie AC-1 [A] 52 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 1000 Figure 6 - AC-2, Switching of slip-ring motors; Ue = 230…400…460V C16 C23 C30 C37 C43 10E+06 C60 C12 C72 C85 C97 Operating cycles C09 01E+06 10E+04 1 10 100 Rated operating current Ie AC-2 [A] Figure 7 - AC-3, Switching of squirrel-cage motors while starting; Ue = 230…400…460V C09 10E+06 C12 C16 C23 C30 C37 C43 Operating cycles C60 C72 C85 C97 01E+06 10E+04 1 10 100 Rated operating current Ie AC-3 [A] Rockwell Automation Publication 100-TD013F-EN-P - November 2017 53 Figure 8 - AC-3, Switching of squirrel-cage motors while starting; Ue = 500…575V C09 10E+06 C12 C16 C23 C30 C37 C43 Operating cycles C60 C72 C85 C97 01E+06 10E+04 1 10 100 Rated operating current Ie AC-3 [A] Figure 9 - AC-3, Switching of squirrel-cage motors while starting; Ue = 690V C09 C12 C16 C23 C30 C37 C43 10E+06 Operating cycles C60 C72 C85 C97 01E+06 10E+04 1 10 Rated operational current Ie AC-3 [A] 54 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100 Figure 10 - AC-4, Switching of squirrel-cage motors; Ue = 230…690V 10E+06 Operating cycles 01E+06 10E+04 C97 C85 C72 C60 C43 C37 C30 C23 10 C16 1 C12 C09 01E+04 100 Rated operating current Ie AC-4 [A] Figure 11 - AC-3 & AC-4, 10% AC-4 Mixed operation of squirrel-cage motors; Ue = 230…400…460V C12 10E+06 C16 C23 C30 C37 C43 C60 Operating cycles C09 C72 C85 C97 01E+06 10E+04 1 10 100 Rated operating current Ie AC-3 / AC-4 [A] Rockwell Automation Publication 100-TD013F-EN-P - November 2017 55 C60/72/85 C97 C43 C30/37 C09/12/16 C23 Figure 12 - Heavy Duty Starting and Regular Short-time Operation max. Starting time / Loading time [s] 100 10 1 10 100 1000 Starting current / Short time current [A] 56 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 10000 Maximum Operating Rates Figure 13 - AC-1, 40 °C Non- or slightly inductive loads, resistance furnaces; Ue = 230…690V 30E+02 Permissible switching rate [ops/hr] 25E+02 20E+02 15E+02 C09/C12/C16/C23 10E+02 C60/C72/C85 05E+02 C30/C37 C40/43 C90/C97 00E+00 0 10 20 30 40 50 60 70 80 90 100 P/Pn [%] Rockwell Automation Publication 100-TD013F-EN-P - November 2017 57 Figure 14 - AC-2, Stepping of slip-ring motors; Ue = 230…460V Permissible switching rate [ops/hr] 01E+04 10E+02 C09/C12/C16 C23/C30/C37/C43 C60/C72 C85/C97 01E+02 0 10 20 30 40 50 60 70 80 P/Pn [%] 58 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 90 100 Figure 15 - AC-3, Switching of squirrel-cage motors while starting; Ue = 230…460V; Relative operating time 40%, Starting time tA = 0.25 s Permissible switching rate [ops/hr] 01E+04 10E+02 C09/C12/C16 C23/C30/C37/C43 C60/C72/C85/C97 01E+02 0 10 20 30 40 50 60 70 80 90 100 P/Pn [%] Rockwell Automation Publication 100-TD013F-EN-P - November 2017 59 Figure 16 - AC-4, Inching of squirrel-cage motors; Ue = 230…460V, Starting time tA = 0.25 s Permissible switching rate [ops/hr] 10E+02 C09 C12 C16 01E+02 C23/C30 C37/C43/C60 C72 C85/C97 10E+00 0 10 20 30 40 50 60 70 P/Pn [%] 60 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 80 90 100 Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. Bulletin 100-C/104-C, 100S-C/104S-C Approximate Dimensions Figure 17 - Bulletin 100-C/100S-C Contactors and Accessories c2 c1 c Figure 18 - Mounting Position — 100-C Contactors; 100S-C AC Contactors and DC contactors with electronic coils Figure 19 - Mounting Position — 100S-C DC contactors Rockwell Automation Publication 100-TD013F-EN-P - November 2017 61 Table 2 - AC Contactors and DC Contactors with 12V or 24V Electronic Coils Cat. No. 100-C09…100-C23 100-C30, 100-C37 100-C40 100-C43, 100-C55 100-C60…100-C97 100-C90 100S-C09…100S-C23 100S-C30, 100S-C37 100S-C43, 100S-C55 100S-C60…100S-C97 a 45 (1-25/32) 45 (1-25/32) 59 (2-21/64) 54 (2-1/8) 72 (2-53/64) 95 (3-47/64) 45 (1-25/32) 45 (1-25/32) 54 (2-1/8) 72 (2-53/64) b 81 (3-3/16) 81 (3-3/16) 81 (3-3/16) 81 (3-3/16) 122 (4-51/64) 122 (4-51/64) 81 (3-3/16) 81 (3-3/16) 81 (3-3/16) 122 (4-51/64) c 80.5 (3-11/64) 97.5 (4) 100.5 (3-61/64) 100.5 (3-61/64) 117 (4-39/64) 117 (4-39/64) 119.5 (4-3/4) 136.5 (5-37/64) 139.5 (5-11/16) 156 (6-11/32) c1 75.5 (2-31/32) 92.5 (3-41/64) 95.5 (3-49/64) 95.5 (3-49/64) 111.5 (4-25/64) 111.5 (4-25/64) 114.5 (4-43/64) 131.6 (5-11/32) 134.6 (5-29/64) 150.5 (6-1/8) c2 6 (15/64) 6.5 (1/4) 6.5 (1/4) 6.5 (1/4) 8.5 (21/64) 8.5 (21/64) 6 (15/64) 6.5 (1/4) 6.5 (1/4) 8.5 (21/64) d 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 4 - 5.4 (4 - 7/32) 4 - 5.4 (4 - 7/32) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 4 - 5.4 (4 - 7/32) d1 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 100 (3-15/16) 100 (3-15/16) 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 100 (3-15/16) d2 35 (1-3/8) 35 (1-3/8) 45 (1-25/32) 45 (1-25/32) 55 (2-11/64) 55 (2-11/64) 35 (1-3/8) 35 (1-3/8) 45 (1-25/32) 55 (2-11/64) c1 111.5 (4-25/64) 111.5 (4-25/64) 140.5 (5-37/64) 158 (6-1/4) 175.5 (6-61/64) 179 (7-3/32) 150.5 (6-1/8) c2 8.5 (21/64) 8.5 (21/64) 6 (15/64) 6 (15/64) 6.5 (1/4) 6.5 (1/4) 8.5 (21/64) d 4 - 5.4 (4 -7/32) 4 - 5.4 (4 - 7/32) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 4 - 5.4 (4 - 7/32) d1 100 (3-15/16) 100 (3-15/16) 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 100 (3-15/16) d2 55 (2-11/64) 55 (2-11/64) 35 (1-3/8) 35 (1-3/8) 35 (1-3/8) 45 (1-25/32) 55 (2-11/64) d1 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) 60 (2-23/64) d2 35 (1-3/8) 35 (1-3/8) 45 (1-25/32) 45 (1-25/32) 35 (1-3/8) 35 (1-3/8) 45 (1-25/32) Table 3 - DC Contactors with Conventional Coils Cat. No. 100-C60D…100-C97D 100-C90D 100S-C09Z...100S-C16Z 100S-C23Z 100S-C30Z...100S-C37Z 100S-C43Z 100S-C60D...100S-C97D a 72 (2-53/64) 95 (3-47/64) 45 (1-25/32) 45 (1-25/32) 45 (1-25/32) 54 (2-1/8) 72 (2-53/64) 122 81 81 81 81 81 122 b (4-51/64) (3-3/16) (3-3/16) (3-3/16) (3-3/16) (3-3/16) (4-51/64) c 117 (4-39/64) 117 (4-39/64) 145.5 (5-49/64) 162.5 (6-7/16) 180.5 (7-5/32) 183.5 (7-17/64) 156 (6-11/32) Table 4 - DC Contactors with 36…48V, 48…72V, 110…125V, or 200…250V DC Electronic Coils Cat. No. 100-C09E…100-C23E 100-C30E…100-C37E 100-C40E 100-C43E…100-C55E 100S-C09E…100S-C23E 100S-C30E…100S-C37E 100S-C43E…100S-C55E 62 a 45 (1-25/32) 45 (1-25/32) 59 (2-21/64) 54 (2-1/8) 45 (1-25/32) 45 (1-25/32) 54 (2-1/8) b 105 (4-1/8) 105 (4-1/8) 105 (4-1/8) 105 (4-1/8) 105 (4-1/8) 105 (4-1/8) 105 (4-1/8) c 80.5 (3-11/64) 97.5 (4) 100.5 (3-61/64) 100.5 (3-61/64) 119.5 (4-3/4) 136.5 (5-37/64) 139.5 (5-11/16) c1 75.5 (2-31/32) 92.5 (3-41/64) 95.5 (3-49/64) 95.5 (3-49/64) 114.5 (4-43/64) 131.6 (5-11/32) 134.6 (5-29/64) c2 6 (15/64) 6.5 (1/4) 6.5 (1/4) 6.5 (1/4) 6 (15/64) 6.5 (1/4) 6.5 (1/4) d 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Table 5 - 100-C/104-C Accessories mm (inches) Auxiliary contact block for front mounting Contactors with 2- or 4-pole c/c1 + 39 (c/c1 + 1-37/64) Auxiliary contact block for side mounting 1- or 2-pole a+9 (a + 23/64) c/c1 + 58 (c/c1 + 2-23/64) b + 24 (b + 15/16) Pneumatic Timing Module Electronic Timing Module on coil terminal side Mechanical Interlock on side of contactor Mechanical Latch a+9 (a + 23/64) c/c1 + 61 (c/c1 + 2-31/64) Interface Module on coil terminal side b+9 (b + 23/64) Surge Suppressor on coil terminal side b+3 (b + 1/8) label sheet +0 (+ 0) marking tag sheet with clear cover +0 (+ 0) Labeling with… Terminal Lug Kit marking tag adapter for System V4 / V5 + 5.5 (+ 7/32) marking tag adapter for System Bul. 1492W + 5.5 (+ 7/32) 100-C09…C23 b + 53 (b + 2-3/32) 100-C30…C37 b + 44 (b + 1-47/64) 100-C43…C55 b + 52 (b+ 2-3/64) 100-C60…C97 b + 99 (b + 3-7/8) 100-C09…C23 b + 78 (b + 3-1/16) c + 9/5 (c + 3/8) 100-C30…C37 b + 85 (b + 3-11/32) mm (inches) 1- or 2-pole a+9 (a + 23/64) Electronic Timing Module on coil terminal side b + 24 (b + 15/16) Mechanical Interlock on side of contactor a+9 (a + 23/64) Interface Module on coil terminal side b+9 (b + 23/64) Surge Suppressor on coil terminal side b+3 (b + 1/8) label sheet +0 (+ 0) Paralleling Links Table 6 - 100S-C/104S-C Accessories Contactors with Auxiliary contact block for side mounting Labeling with marking tag sheet with clear cover +0 (+ 0) marking tag adapter for System V4 / V5 + 5.5 (+ 7/32) marking tag adapter for System Bul. 1492W + 5.5 (+ 7/32) Rockwell Automation Publication 100-TD013F-EN-P - November 2017 63 Bulletin 100Q-C Approximate Dimensions Figure 20 - Bulletin 100Q- Contactors c2 c1 c Table 7 - AC Contactors and DC Contactors with 12V or 24V Electronic Coils Cat. No. 100Q-C16 100Q-C37 a 45 (1-25/32) 45 (1-25/32) b 81 (3-3/16) 81 (3-3/16) c 119.5 (4-3/4) 136.5 (5-37/64) c1 114.5 (4-43/64) 131.6 (5-11/32) c2 6 (15/64) 6.5 (1/4) d 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) d1 60 (2-23/64) 60 (2-23/64) d2 35 (1-3/8) 35 (1-3/8) c1 140.5 (5-37/64) 175.5 (6-61/64) c2 6 (15/64) 6.5 (1/4) d 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) d1 60 (2-23/64) 60 (2-23/64) d2 35 (1-3/8) 35 (1-3/8) d1 60 (2-23/64) 60 (2-23/64) d2 35 (1-3/8) 35 (1-3/8) Table 8 - DC Contactors with Conventional Coils Cat. No. 100Q-C16 100Q-C37 a 45 (1-25/32) 45 (1-25/32) b 81 (3-3/16) 81 (3-3/16) c 145.5 (5-49/64) 180.5 (7-5/32) Table 9 - DC Contactors with 36…48V, 48…72V, 110…125V, or 200…250V DC Electronic Coils Cat. No. 100Q-C16EA, -ED, or -EY 100Q-C37EA, -ED, or -EY 64 a 45 (1-25/32) 45 (1-25/32) b 105 (4-1/8) 105 (4-1/8) c 119.5 (4-3/4) 136.5 (5-37/64) c1 114.5 (4-43/64) 131.6 (5-11/32) c2 6 (15/64) 6.5 (1/4) d 2 - 4.5 (2 -3/16) 2 - 4.5 (2 -3/16) Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Accessories Auxiliary Contact Blocks Cat. No. Description(1) Connection Diagrams For Use With N.O. N.C. 0 2 1 1 2 0 1L 1L 0 1 4 3 2 2 3 1 \ Auxiliary Contact Blocks for Front Mounting • 2- and 4-pole • Quick and easy mounting without tools • Electronic-compatible contacts down to 17V, 5mA • Mechanically linked performance between N.O. and N.C. poles and to the main contactor poles (except for L types) • Models with equal function with several terminal numbering choices • 1L = Late break N.C. / early make N.O. • Bifurcated version for switching down to 5V, 3 mA also available Auxiliary Contact Blocks for Side Mounting without Sequence Terminal Designations • 1- and 2-pole • Two-way numbering for right or left mounting on the contactor • Quick and easy mounting without tools • Electronic-compatible contacts down to 17V, 10 mA • Mirror contact performance to the main contactor poles • 1L = Late break N.C. / early make N.O. Auxiliary Contact Blocks for Side Mounting with Sequence Terminal Designations • 1- and 2-pole • Two-way numbering for right or left mounting on the contactor • Quick and easy mounting without tools • Electronic-compatible contacts down to 17V, 10 mA • Mirror contact performance to the main contactor poles • 1L = Late break N.C. / early make N.O. 4 0 1 + 1L 1+1L 0 1 1 0 0 2 1 1 2 0 100-C all C3000...C9700 100-C all C3000...C9700 C0910...C2310 100-C all C3000...C9700 100-C all C3000...C9700 100-C all 100-C all 100-C all C3000...C9700 C0910...C2310 100-C all C0910...C2310 100-C all 100-C all 100-C all 100-C all 100-C all 100-C all 100-C all Standard Auxiliary Contact(2) 100-FA02 100-FB02 100-FA11 100-FB11 100-FC11 100-FA20 100-FB20 100-FAL11 100-FBL11 100-FA04 100-FA13 100-FA22 100-FB22 100-FC22 100-FA31 100-FC31 100-FA40 100-FAL22 100-SA01 100-SA10 100-SA02 100-SA11 100-SA20 Bifurcated Auxiliary Contact 100-FAB02 100-FBB02 100-FAB11 100-FBB11 100-FCB11 100-FAB20 100-FBB20 — — 100-FAB04 100-FAB13 100-FAB22 100-FBB22 100-FCB22 100-FAB31 100-FCB31 100-FAB40 — — — — — — 1L 1L 100-C all 100-SAL11 — 0 1 0 1 2 1 0 2 1 0 100-C 100-C(3) 100-C(3) 100-C(3) 100-C(3) 100-SB01 100-SB10 100-SB02 100-SB11 100-SB20 — — — — — 1L 1L 100-C(3) 100-SBL11 — (1) Max. number of auxiliary contacts that may be mounted: AC and 24V DC electronic coil contactors—max. 4 N.O contacts on the front of the contactor, 2 N.O. contacts on the side, 4 N.C. front or side, 6 total. DC Coil contactors—max. 4 N.O. contacts on the front of the contactor or max. 2 N.O. contacts on the side, 4 N.C. front or side, 4 total. (2) For screwless terminals (front mount only), insert "CR" after the "100-" in the catalog number. Example: Cat. No. 100-FA02 becomes Cat. No. 100-CRFA02. (3) Double numbering—Left-side mounting only is recommended for Cat. No. 100-C09...100-C23 due to double numbering. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 65 Control Modules Timers Connection Diagrams Description Pneumatic Timing Modules • Pneumatic timing element contacts switch after the delay time. The contacts on the main control relay continue to operate without delay On-Delay, 0.3…30 s 2...180 s Off-Delay 0.3...30 s For Use With Cat. No. 100-C or 700-CF with AC or 24V DC electronic coils(1) 100-FPTA30 100-C all, 700-CF all 100-FPTB180 0.1...3 s 1...30 s 100-ETA3 100-ETA30 100-C or 700-CF with 110...240V, 50/60Hz or 110...250V DC coils 100-ETA180 100-ETAZJ3 100-ETAZJ30 0.1...3 s 1...30 s 100-C or 700-CF with 24...48VDC coils 10...180 s Electronic Timing Modules — Off-Delay • Delay of the contactor or control relay solenoid. After interruption of the control signal, the contactor or control relay is deenergized at the end of the delay time. 100-FPTB30 2...180 s 10...180 s Electronic Timing Modules — On-Delay • Delay of the contactor or control relay solenoid. The contactor or control relay is energized at the end of the delay time. 100-FPTA180 0.3...3 s 1...30 s 10...180 s 0.3...3 s 1...30 s 10...180 s 100-C09...C37 or 700-CF with 24V 50/60Hz 100-C or 700-CF with 110...240V 50/60Hz coils Electronic Timing Modules • Delay of the contactor solenoid. Contactor K 3(Y) is de-energized (off) and K 2 (D) is energized (on) after the end of the set Y end Transition Time Y time. (Switching delay at 50 ms.) Contactor 1...30 s • Continuous adjustment range • High repeat Mechanical Interlocks • For interlocking of two contactors. • Common interlock for most Bul. 100-C contactor sizes • Interlocking or different sizes possible • Mechanical and electrical interlocking possible in one module by means of integrated auxiliary contacts • 9 mm dovetail connector included Mechanical only, without auxiliary contacts Mechanical/ electrical interlock with 2 N.C. auxiliary contacts Mechanical Latch • Following contactor latching, the contactor coil is immediately de-energized (off) by the N.C. auxiliary contact (65-66). • Electrical or manual release • 1 N.O. + 1 N.C. auxiliary contacts • Suitable for all Bul. 100-C contactor sizes, 9...97 A Maximum command duration 0.03...10 s 100-ETAZJ180 100-ETBKJ3 100-ETBKJ30 100-ETBKJ180 100-ETB3 100-ETB30 100-ETB180 100-C with 110...240V 50/ 60Hz coils 100-ETY30 100-C (except 100-C40, -C90) 100-MCA00 100-C (except 100-C40, -C90) 100-MCA02 100-C with AC or 24V DC electronic coils (except 100-C90) 100-FL11 (1) Cannot be used with side-mounted auxiliary contacts on 700-CF DC relays. Coil Voltage Code: The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 60 Hz: Cat. No. 100-FL11 becomes Cat. No.100-FL11D AC Voltages [V](1) 50 Hz 60 Hz 24 48 100 110 120 230...240 240 277 K J Y — KP — D — — D VA — KA KA — T 380...400 400...415 N — G — (1) For special voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. 66 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 440 480 B N — B Control Modules (For 100-C09...C97 contactors), Continued Description Input: 12V DC Output: 110...240V AC Input: 18...30V DC Output: 110...240V AC DC Interface (Electronic) • Interface between the DC control signal (PLC) and the AC operating mechanism of the contactor. • Requires no additional surge suppression on the relay coils. RC Module AC operating mechanism Surge Suppressors • For limitation of coil switching transients. • Plug-in, coil mounted. • Suitable for 100-C contactor sizes, 9...97 A. • RC, varistor, and diode versions. Varistor Module AC/DC operating mechanism Connection Diagrams Voltage Range For Use With Cat. No. 100-JE12 100-C with AC coils 110...240V AC 100-JE Input: 48V DC Output: 110...240V AC 100-JE48 24...48V AC, 50/60 Hz 110...280V AC, 50/60 Hz 100-FSC48(1) 100-FSC280(1) 100-C with Coils 380...480V AC, 50/60 Hz 100-FSC480(1) 12...55V AC, 12...77V DC 56...136V AC/78...180V DC 137...277V AC/ 181...350V DC 100-FSV55(1) 100-FSV136(1) 100-C with AC coils or 100-C09...-C43 with DC coils 100-FSV575(1) 278...575V AC Diode Module DC operating mechanism 100-FSV277(1) 1...30 s 10...180 s 100-C09...-C43 with DC coils 100-FSD250(1) Pkg. Qty. Cat. No. 10 100-S0 (1) For screwless terminals, insert “CR” after the “100-” in the catalog number. Example: Cat No. 100-FSC48 becomes Cat. No.-CRFSC48. Assembly Components (For 100-C09...C97 contactors) Description Dovetail Connectors • For use in contactor and starter assemblies • Single Connector — 0 mm spacing Dovetail Connectors • For use in contactor and starter assemblies • Single Connector — 9mm spacing Protective Covers • Provides protection against unintended manual operation • For contactors and front-mounted auxiliary contacts, pneumatic timers, and latches Reversing Power Wiring Kits • For reversing connection with a solid-state or thermal overload relay DIN (#3) symmetrical hat rail • 35 x 7.5 x 1 m For Use With 100-C 10 100-C all 1 100-SCCA 100-FA, -FB, -FC, -FP, -FL 10 100-SCFA 100-C09...C23 100-C30...C37 100-C43…C55 1 1 1 105-PW23 105-PW37 105-PW55 100-C60...C97 1 105-PW85 140M-D 140M-F 100-C all 10 199-DR1 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 67 Wye-Delta/Star-Delta Starter Kits Wye-Delta power wiring kits are designed to aid in the field assembly of open-transition wye-delta starters that use Bulletin 100-C contactors. These kits include line, load, and start-point (shorting) connections. Assembling a wye-delta starter requires the use of the following additional components: • Contactors • Overload Relay • Cat. No. 100-MCA02 Mechanical/Electrical Interlock Cat. No. 100-ETY30 Electronic Y- Timer • Cat. No. 100-S9 Base Coupler for 1M to 2M contactor (optional) 3-Phase Rating Hp (60 Hz) kW (50 Hz) 230V 380/ 415V 500V 690V 200V 230V 460V 575V 5.5 7.5 10 13 17 20 22 30 32 40 50 50 7.5 11 15 22 25 37 40 45 55 63 80 90 7.5 11 15 22 25 32 40 45 55 63 80 90 7.5 10 13 18.5 25 32 40 45 55 63 80 90 5 5 7.5 7.5 10 15 20 25 30 40 50 50 5 7.5 10 10 15 20 25 30 40 50 60 60 10 15 20 25 30 40 50 60 75 100 125 125 10 15 20 25 30 40 50 60 75 100 125 125 Use with Cat. No. 100Delta Wye 1M 2M 1S C09 C09 C09 C12 C12 C09 C16 C16 C12 C23 C23 C12 C30 C30 C16 C37 C37 C23 C43 C43 C30 C55 C55 C37 C60 C60 C37 C72 C72 C43 C85 C85 C60 C97 C97 C60 Pkg Qty. Cat. No. 1 1 1 1 1 1 1 1 1 1 1 1 170-PW23 170-PW23 170-PW23 170-PW23 170-PW37 170-PW37 170-PW55 170-PW55 170-PW72 170-PW72 170-PW85 170-PW85 Marking Systems (For 100-C09...C97 contactors) Pkg. Qty.(1) Cat. No. Label Sheet • 105 self-adhesive paper labels each, 6 x 17 mm 10 100-FMS Marking Tag Sheet • 106 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover 10 100-FMP Transparent Cover • To be used with marking tag sheets 100 100-FMC Marking Tag Adapters • To be used with marking tag: System V7 100 100-FMA1 Marking Tag Adapters • To be used with marking tag: System 1492 W 100 100-FMA2 Description (1) Must be ordered in multiples of package quantities 68 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Terminal Kits (For 100-C09…C97 contactors) Pkg. Qty(2) Cat. No. Stab Connector Kit • Dual stab (0.250 in.) for 100-C coil terminals • For 100-C09…C97 contactors 20 199-SC2 Stab Connector Kit • Dual stab (0.250 in.) for 100-C power terminals • For 100-C09…C23 contactors 100 199-SC10 1 100-CTN23 1 100-CTL23 1 100-CT37 3 100-CT43 3 100-CT85 2 100-CP23 2 100-CP37 Description 3-Pole Terminal Lug Kit • For Cat. No. 100-C09…C23 (Line side) 3-Pole Terminal Lug Kit • For Cat. No. 100-C09…C23 (Load side) 3-Pole Terminal Lug Kit • For Cat. No. 100-C30…C37 (Line and load side) 1-Pole Terminal Lug Kit • For Cat. No. 100-C43 1-Pole Terminal Lug Kit • For Cat. No. 100-C60…C97 3-Pole Paralleling Kit • For Cat. No. 100-C09…C23 3-Pole Paralleling Kit • For Cat. No. 100-C30…C37 Max. Current Ratings and Wire Sizes IEC @ 40 °C IEC 45 A (4…16 mm2, fine stranded w/ ferrule)(1) @ 40 °C 45 A (4…25 mm2, coarse stranded/solid) UL/CSA (Encl.) 40 A (#10…4 AWG, stranded/solid) IEC @ 40 °C IEC 45 A (4…16 mm2, fine stranded w/ ferrule) @ 40 °C 45 A (4…25 mm2, coarse stranded/solid) UL/CSA (Encl.) 40 A (#10…4 AWG, stranded/solid) IEC @ 40 °C IEC 60 A (4…16 mm2 , fine stranded w/ ferrule) @ 40 °C 60 A (4…25 mm2, coarse stranded/solid) UL/CSA (Encl.) 55 A (#10…4 AWG, stranded/solid) IEC @ 40 °C IEC 90 A (6…35 mm2, fine stranded w/ ferrule) @ 40 °C 90 A (6…50 mm2, coarse stranded/solid) UL/CSA (Encl.) 75 A (#8…2 AWG, stranded/solid) IEC @ 40 °C IEC 130 A (10…70 mm2, fine stranded w/ ferrule) 130 @ 40 °C A (10…95 mm2, coarse stranded/solid) UL/CSA (Encl.) 130 A (#8…2/0 AWG, stranded/solid) IEC @ 40 °C IEC 100 A (35…70 mm2, fine stranded w/ ferrule) 100 @ 40 °C A (35…95 mm2, coarse stranded/solid) UL/CSA (Encl.) 100 A (#0…2/0 AWG, stranded/solid) IEC @ 40 °C IEC 150 A (35…70 mm2, fine stranded w/ ferrule) 150 @ 40 °C A (35…95 mm2, coarse stranded/solid) UL/CSA (Encl.) 150 A (#0…2/0 AWG, stranded/solid) (1) 16 mm2 max. according to IEC 60947; actual max. 25 mm2 (2) Must be ordered in multiples of the package quantity. SEMI-F47 Voltage Sag Immunity Module Description SEMI-F47 Module • Meets SEMI-F47 voltage sag immunity requirements • Direct mounting to coil terminals of 100-C contactors and 700-CF control relays • Requires DC coil contactor • Optional 1…30 s ON-delay timer version Input Voltage 24…240V AC For Use With(1) 100-C60…C97 Options without timer Cat. No. 100-CSF47 110…240V AC 100-C60…C97 with 1…30 s ON-delay timer 100-CSF47A30 (1) Contactor must have DC coil at the same voltage as AC input. Example: for 24V AC control, select Cat. No. 100-C09ZJ10 (24V DC coil). Rockwell Automation Publication 100-TD013F-EN-P - November 2017 69 Renewal Parts Replacement Coils for AC Contactors AC Standard Control Voltages [V] 50 Hz 60 Hz 50/60 Hz — 12 — 12 — — — 24 — 24 — — — — 24 32 36 — 36 42 — 42 48 — 48 — — — — 48 100 100…110 100 110 120 — — — 110 120 — — 127 — — 200 200…220 200 — 208 — 200…220 208…240 — — — 200…230 220 240 — 220…230 260 — — — 230 230…240 — — 240 277 — — — 240 — 347 — — 380 — 380…400 440 — — — 400 400…415 — — 440 480 — — — 440 500 — — 550 600 — 70 AC Coil Code Q R J K KJ V W X Y KY KP D KD P S KG H L KL A F KF VA T KA I E N KN G B KB M C 100-C09…100-C16 Cat. No. TA006 TA404 TA013 TA407 TA855 TA481 TA410 TA482 TA414 TA860 TA861 TA473 TA856 TA425 TA428 TA862 TA049 TA296 TA864 TA474 TA441 TA851 TA440 TA480 TA858 TA065 TA067 TA071 TA863 TA457 TA475 TA859 TA479 TA476 100-C23…100-C37, 100L-C20 Cat. No. TC006 TC404 TC013 TC407 TC855 TC481 TC410 TC482 TC414 TC860 TC861 TC473 TC856 TC425 TC428 TC862 TC049 TC296 TC864 TC474 TC441 TC851 TC440 TC480 TC858 TC065 TC067 TC071 TC863 TC457 TC475 TC859 TC479 TC476 100-C40, -C43 100-C60…100-C85 100-C90…100-C97 Cat. No. TD006 TD404 TD013 TD407 TD855 TD481 TD410 TD482 TD414 TD860 TD861 TD473 TD856 TD425 TD428 TD862 TD049 TD296 TD864 TD474 TD441 TD851 TD440 TD480 TD858 TD065 TD067 TD071 TD863 TD457 TD475 TD859 TD479 TD476 Cat. No. TE006 TE404 TE013 TE407 TE855 TE481 TE410 TE482 TE414 TE860 TE861 TE473 TE856 TE425 TE428 TE862 TE049 TE296 TE864 TE474 TE441 TE851 TE440 TE480 TE858 TE065 TE067 TE071 TE863 TE457 TE475 TE859 TE479 TE476 Cat. No. TF006 TF404 TF013 TF407 TF855 TF481 TF410 TF482 TF414 TF860 TF861 TF473 TF856 TF425 TF428 TF862 TF049 TF296 — TF474 TF441 TF851 TF440 TF480 TF858 TF065 TF067 TF071 TF863 TF457 TF475 TF859 TF479 TF476 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Replacement Coils for DC Contactors DC Standard Control Voltage [V] DC Coil Code 9(1) 9V Diode(1) 12 12V Diode 24(2) 24 Diode(2) 36 36V Diode 48 48V Diode 60 60V Diode 64 64V Diode 72 72V Diode 80 80V Diode 110 110V Diode 115 115V Diode 125 125V Diode 220 220V Diode 230 230V Diode 250 250V Diode ZR DR ZQ DQ ZJ DJ ZW DW ZY DY ZZ DZ ZB DB ZG DG ZE DE ZD DD ZP DP ZS DS ZA DA ZF DF ZT DT 100-C09…100-C16 Cat. No. TA766 — TA708 — TA714 TA714M TA719 — TA724 — TA774 — TA727 — TA728 — TA729 — TA733 — TA734 — TA737 — TA747 — TA749 — TA751 — 100-C23…100-C37, 100L-C20 Cat. No. TC766 — TC708 — TC714 TC714M TC719 — TC724 — TC774 — TC727 — TC728 — TC729 — TC733 — TC734 — TC737 — TC747 — TC749 — TC751 — 100-C40, -C43 100-C60…100-C85 100-C90…100-C97 Cat. No. TD766 — TD708 — TD714 TD714M TD719 — TD724 — TD774 — TD727 — TD728 — TD729 — TD733 — TD734 — TD737 — TD747 — TD749 — TD751 — Cat. No. — TE766M — TE708M — TE714M — TE719M — TE724M — TE774M — TE727M — TE728M — TE729M — TE733M — TE734M — TE737M — TE747M — TE749F — TE751F Cat. No. — TF766M — TF708M — TF714M — TF719M — TF724M — TF774M — TF727M — TF728M — TF729M — TF733M — TF734M — TF737M — TF747M — TF749F — TF751F (1) Voltage operating range: 0.65…1.3 x Us. (2) Voltage operating range: 0.7…1.25 x Us. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 71 Notes: 72 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100-E/104-E, 100S-E/104S-E Contactors Product Selection—100-E/104-E Contactors • • • • • 55…560 kW @ 400V 75…900 HP @ 460V AC-1 ratings up to 2650 A Compact Dimensions Electronic Coils – AC/DC – Wide voltage ranges – Low power pick-up and hold-in – Optional PLC interface • Complete range of accessories • Environmentally friendly 100-E116 Contactor 100-E860 Contactor The Bulletin 100-E/104-E contactor family, along with a wide range of accessories, provides the most compact and flexible contactor system available. 3-Pole AC- and DC-operated Contactors • Electronic Coils • 3 Main Contacts • Direct On-Line or Reversing Rated Operational Current Ie [A] 60 °C 40 °C AC-3 AC-1 (400V) (690V) 220-240V 380-400V 116 160 37 55 146 225 45 75 190 275 55 90 205 350 55 110 265 400 75 132 305 500 90 160 370 600 110 200 400 600 110 200 460 700 132 250 580 800 160 315 750 1050 220 400 860 1350 250 475 1060 1650 315 560 — 1260 — — — 2050 — — — 2650 — — Auxiliary Contacts Ratings for switching AC motors - AC-2, AC-3 kW (50 Hz) 415V 55 75 90 110 132 160 200 220 250 355 425 500 630 — — — 440V 75 90 110 132 160 160 200 220 250 355 450 560 710 — — — Direct On-Line Contactor Reversing Contactor Cat No. Cat No. Hp (60 Hz) 500V 75 90 90 110 160 200 220 250 315 400 530 560 710 — — — 690V 55 90 132 160 200 250 315 315 355 500 600 800 1000 — — — 1000V — 75 110 132 132 132 132 220 280 355 400 555 600 — — — 200V 30 40 50 60 75 100 125 125 150 200 250 — — — — — 230V 40 50 60 75 100 125 150 150 200 250 300 400 450 — — — 460V 75 100 125 150 200 250 300 350 400 500 600 800 900 — — — 575V 100 125 150 200 250 300 350 400 500 600 700 1000 1150 — — — N.O. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N.C. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 (1) 100-E11611 100-E14611 (1) 100-E19011 100-E20511 100-E26511 100-E30511 100-E37011 100-E40011 100-E46011 100-E58011 100-E75011 100-E86011 100-E106011 100-E126011 100-E205011 100-E265011 104-E11622 (1) 104-E14622 (1) 104-E19022 104-E20522 104-E26522 104-E30522 104-E37022 104-E40022 104-E46022 104-E58022 104-E75022 — — — — — (1) To order with built-in terminal lugs, add the letter "L" to the end of the catalog number (e.g. 100-E11611L) Coil voltage code and PLC interface—see page 74 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 73 Coil Voltage Codes The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 100-E116KJ11) Electronic Coils V 24-60V 48-130V 100-250V 250-500V 100-E116…100-E370 100-E116…100-E370 100-E400…100-E750 100-E860…100-1060 100-E1260 100-E2050…100-E2650 AC/DC KJ — EJ (2) — EJ (1) — KY — EY — EY — KD ED ED ED ED ED KN EN EN — EN — AC/DC with PLC Input PLC Interface 0V Supply voltage A1 A2 X5 Contactor ON 1 OFF_N 2 COMMON 3 24V ON OFF (1) 24V…60V DC only Product Selection—100S-E Safety Contactors 3-Pole AC- and DC-operated Safety Contactors • • • • • Electronic Coils 3 Main Contacts Direct On-Line Low-power auxiliary contact for feedback circuit Mirror contact performance Rated Operational Current Ie [A] 60 °C 40 °C kW (50 Hz) AC-3 AC-1 220-240V 380-400V 415V (400V) (690V) 116 146 190 205 265 305 370 400 460 580 750 160 225 275 350 400 500 600 600 700 800 1050 Auxiliary contacts per contactor Ratings for switching AC motors - AC-2, AC-3 37 45 55 55 75 90 110 110 132 160 220 55 75 90 110 132 160 200 200 250 315 400 55 75 90 110 132 160 200 220 250 355 425 Hp (60 Hz) 440V 500V 690V 1000V 200V 230V 460V 575V N.O. N.C. N.C.(1) Cat No. 75 90 110 132 160 160 200 220 250 355 450 75 90 90 110 160 200 220 250 315 400 530 55 90 132 160 200 250 315 315 355 500 600 — 75 110 132 132 132 132 220 280 355 400 30 40 50 60 75 100 125 125 150 200 250 40 50 60 75 100 125 150 150 200 250 300 75 100 125 150 200 250 300 350 400 500 600 100 125 150 200 250 300 350 400 500 600 700 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 100S-E116⊗12C(2) (1) The N.C. contact meets IEC 60947-4-1 Annex F requirements for mirror contact performance. (2) To order with built-in terminal lugs, add the letter "L" to the end of the catalog number (e.g. 100S-E116⊗12CL) Coil voltage code and PLC interface—see page 75 74 Direct On-Line Contactor Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100S-E146⊗12C(2) 100S-E190⊗12C 100S-E205⊗12C 100S-E265⊗12C 100S-E305⊗12C 100S-E370⊗12C 100S-E400⊗12C 100S-E460⊗12C 100S-E580⊗12C 100S-E750⊗12C Coil Voltage Codes The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 100S-E116KJ11) Electronic Coils V 24-60V 48-130V 100-250V 250-500V 100S-E116…100S-E370 AC/DC KJ KY KD KN — — ED EN EJ (1) EY ED EN 100S-E116…100S-E370 100S-E400…100S-E750 AC/DC with PLC Input PLC Interface 0V 24V ON OFF Supply voltage A1 A2 X5 Contactor ON 1 OFF_N 2 COMMON 3 (1) 24V…60V DC only Specifications 100-E, 100S-E 116…2650 Rated Isolation Voltage Ui IEC UL, CSA Rated Impulse Voltage Withstand Uimp Rated Voltage Ue AC 50/60 Hz DC Electromagnetic compatibility Insulation Class of the Coil Rated coil frequency Ambient Temperature Storage Operation at rated voltage Max. Altitude of Installation Site Climatic Withstand Resistance to Shock Resistance to Vibration Protection Class Contactor main contacts Contactor coil terminals Auxiliary contacts [V] [V] [kV] [V] [V] [°C] [°C] [m] 1000 600 8 Standards and Approvals Standards 115, 200, 230, 240, 400, 415, 460 500, 575, 690, 1000 24, 48, 110, 220, 440 IEC 60947-1 - EnviroN•ment A Class F per IEC 60947-4-1 AC 50/60 Hz, DC -40…+70 -40…+70 3000 100-E116-370: IEC 60068-2-30 Test Db & IEC 60068-2-2 test Bd & IEC 60068-2-1 test Ab (report 1314369) 100-E400-2650: IEC 60068-2-2 test Ba & Bb & IEC 60068-2-1 test Aa&Ab, IEC 60068-2-30 IEC 60068-2-27 IEC 60068-2-6 IEC/EN 60947-1, Low-voltage switchgear and controlgear; IEC/EN 60947-4-1, Low-voltage switchgear and controlgear, Contactors and motor-starters; IEC/EN 60947-5-1, Low-voltage switchgear and controlgear, Control circuit devices and switching elements; UL 60947-4-1, Industrial Control Equipment (USA); CSA C22.2 No. 60947-4-1 Industrial Control Equipment (Canada). Mechanically Linked Contacts: IEC 60947-5-1, Annex L 100/100S-E116…100/100SMirror Contacts: IEC 60947-4-1, E750 with all 100-ES* Annex F side mounted N.C. auxiliary contacts Approvals Certifications UL CSA CCC EAC RCM RINA ABS CE SUVA SEMI-F47 cULus, File No. E41850 / E196120 (contactors, reversing contactors) √ √ √ √ √ √ √ Conditions of use on request IP00 P2X (in connected state) P2X (in connected state) Rockwell Automation Publication 100-TD013F-EN-P - November 2017 75 Main Circuits 100/104-E, 100S-E 116 146 190 205 265 305 370 400 460 580 750 860 1060 1260 2050 2650 X X X X X X X X X X X X X X X X [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] [kW] 160 225 275 350 400 500 600 600 700 800 1050 1350 1650 1260 2050 2650 — 225 250 275 350 375 400 600 700 800 1000 1350 1650 1260 2050 2650 64 90 110 139 159 199 239 239 279 319 418 538 657 502 817 1056 Electronic Coil Type: AC-1 Active Power Load (50/60 Hz); Ambient temperature 40°C 690V 1000V 230V 240V 400V 415V 500V 690V 1000V 67 94 114 145 166 208 249 249 291 333 436 561 686 524 852 1102 111 156 191 242 277 346 416 416 485 554 727 935 1143 873 1420 1836 115 162 198 252 288 359 431 431 503 575 755 970 1186 906 1474 1905 139 195 238 303 346 433 520 520 606 693 909 1169 1429 1091 1775 2295 191 269 329 418 478 598 717 717 837 956 1255 1613 1972 1506 2450 3167 — 390 433 476 606 650 693 1039 1212 1386 1732 2338 2858 2182 3551 4590 [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] [kW] 145 200 250 300 350 400 500 500 600 700 875 1150 1450 1040 1750 2350 — 200 225 250 300 325 350 500 600 700 875 1150 1450 1040 1750 2350 58 80 100 120 139 159 199 199 239 279 349 458 578 414 697 936 60 83 104 125 145 166 208 208 249 291 364 478 603 432 727 977 100 139 173 208 242 277 346 346 416 485 606 797 1005 721 1212 1628 104 144 180 216 252 288 359 359 431 503 629 827 1042 748 1258 1689 126 173 217 260 303 346 433 433 520 606 758 996 1256 901 1516 2035 173 239 299 359 418 478 598 598 717 837 1046 1374 1733 1243 2091 2809 — 346 390 433 520 563 606 866 1039 1212 1516 1992 2511 1801 3031 4070 [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] [kW] [mm2] 130 175 200 240 290 325 400 400 480 580 720 1000 1270 875 1500 2120 — 175 185 200 240 260 290 400 480 580 720 1000 1270 875 1500 2120 52 70 80 96 116 129 159 159 191 231 287 398 506 349 598 845 54 73 83 100 121 135 166 166 200 241 299 416 528 364 624 881 90 121 139 166 201 225 277 277 333 402 499 693 880 606 1039 1469 93 126 144 173 208 234 288 288 345 417 518 719 913 629 1078 1524 113 152 173 208 251 281 346 346 416 502 624 866 1100 758 1299 1836 155 209 239 287 347 388 478 478 574 693 860 1195 1518 1046 1793 2534 — 303 320 346 416 450 502 693 831 1005 1247 1732 2200 1516 2598 3672 70 95 150 240 (1) 240 Ambient temperature 60°C 690V 1000V 230V 240V 400V 415V 500V 690V 1000V Ambient temperature 70°C 690V 1000V 230V 240V 400V 415V 500V 690V 1000V With conductor sizes (1) (2) (3) (4) 76 300 (2) 2x185 (2) 2x185 2x240 2x240 800 (3) 1000 (4) 1500 (4) 1000 (3) 2000 (4) 3000 (4) For currents above 275A, use terminal extensions. For currents above 450A, use terminal extensions. Maximum connection bar width 50 mm. Maximum connection bar width 100 mm. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100/104-E, 100S-E Electronic Coil Type: 116 146 190 205 265 305 370 400 460 580 750 860 1060 1260 2050 2650 X X X X X X X X X X X X X X X X 116 146 190 205 265 305 370 400 460 580 750 860 1060 — — — 116 146 190 205 265 305 370 400 460 580 750 860 1060 — — — 116 146 190 205 265 305 370 400 460 580 750 860 1060 — — — 116 146 190 205 265 305 370 400 460 580 750 860 1060 — — — 110 130 135 165 250 290 315 400 460 580 750 800 970 — — — — Switching of 3-phase Motors; (50 Hz) Ambient temperature 60°C, AC-2, AC-3 [A] 380-400V [A] 415V [A] 440V [A] 500V [A] 690V [A] 1000V [A] 220-240V [kW] 380-400V [kW] 415V [kW] 440V [kW] 500V [kW] 690V [kW] 1000V [kW] 220-240V 65 93 135 165 250 290 315 350 400 500 650 800 970 — — — 60 85 100 100 100 100 155 200 250 300 375 400 — — — 37 45 55 55 75 90 110 110 132 160 220 250 315 — — — 55 75 90 110 132 160 200 200 250 315 400 475 560 — — — 55 75 90 110 132 160 200 220 250 355 425 500 630 — — — 75 90 110 132 160 160 200 220 250 355 450 560 710 — — — 75 90 90 110 200 200 220 250 315 400 530 560 710 — — — 55 90 132 160 200 250 315 315 355 500 600 800 1000 — — — — 75 110 132 132 132 132 220 280 355 400 555 600 — — — [A] 160 200 250 300 350 400 520 550 650 750 900 1350 1650 1210 2100 2700 [A] [A] [A] [A] [Hp] [Hp] [Hp] [Hp] [A] [A] [A] [A] 92 120 150 177 221 285 359 359 414 552 692 954 1030 — — — 104 130 154 192 248 312 360 360 480 604 722 954 1030 — — — 96 124 156 180 240 302 361 414 477 590 722 954 1030 — — — 99 125 144 192 242 289 336 382 472 578 672 944 1050 — — — 30 40 50 60 75 100 125 125 150 200 250 — — — — — Load Carrying Capacity per UL/CSA General Purpose Current (enclosed) Rated Power (enclosed) 200V 230V 460V 3-phase 575V 200V 230V 460V 575V 260V DC With 3 poles in series 300V DC 340V DC 600V DC 40 50 60 75 100 125 150 150 200 250 300 400 450 — — — 75 100 125 150 200 250 300 350 400 500 600 800 900 — — — 100 125 150 200 250 300 350 400 500 600 700 1000 1150 — — — 160 200 — — — — — — — — — — — — — — — — 230 250 — — — — — — — — — — — — — — — — 350 400 520 — — — — — — — — — — — — — — — — 500 650 750 900 1050 1350 1210 1900 — Rockwell Automation Publication 100-TD013F-EN-P - November 2017 77 100/104-E, 100S-E Electronic Coil Type: 116 146 190 205 265 305 370 400 460 580 750 860 1060 1260 2050 2650 X X X X X X X X X X X X X X X X Switching of 3-phase Motors, (50Hz); Ambient temperature 60°C, AC-4 230V 240V 400V 415V 500V 690V 1000V 230V 240V 400V 415V 500V [A] [A] [A] [A] [A] [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] [kW] 84 103 128 156 195 230 280 307 377 — — — — — — — 84 103 128 156 195 230 280 307 377 — — — — — — — 84 103 128 156 195 230 280 307 377 — — — — — — — 84 103 128 156 195 230 280 307 377 — — — — — — — 84 103 128 156 195 230 280 307 377 — — — — — — — 66 80 93 104 153 162 188 313 350 — — — — — — — — — 48 72 85 90 95 100 141 155 — — — — — — 25 32 40 50 55 75 90 90 110 — — — — — — — 25 32 40 50 63 75 90 100 125 — — — — — — — 45 55 63 80 110 132 160 160 200 — — — — — — — 45 55 63 90 110 132 160 160 220 — — — — — — — 55 63 90 110 132 160 200 220 250 — — — — — — — 63 75 90 100 150 160 185 315 335 — — — — — — — — 63 100 110 125 132 132 200 220 — — — — — — — 230V 38 38 49 55 73 89 100 118 135 — — — — — — — 240V 38 38 49 55 73 89 100 118 135 — — — — — — — 38 38 49 55 73 89 100 118 135 — — — — — — — 33 33 37 44 53 59 68 78 89 — — — — — — — 33 33 37 44 53 59 68 78 89 — — — — — — — — — — — — — — — — — — — — — — — 11 11 13 15 22 25 30 37 40 — — — — — — — 11 11 15 15 22 25 32 37 45 — — — — — — — 20 20 25 30 40 50 55 63 75 — — — — — — — 20 20 25 30 40 50 55 63 75 — — — — — — — 22 22 25 30 37 40 45 55 63 — — — — — — — 690V 1000V AC-4 at approximately 200,000 operations [A] [A] 400/415V [A] 500V [A] 690V [A] 1000V [A] 230V [kW] 240V [kW] 400V [kW] 415V [kW] 500V [kW] 690V [kW] 1000V [kW] Max. switching frequency Ops/h 30 30 32 40 50 55 63 75 80 — — — — — — — — — — — — — — — — — — — — — — — 150 150 150 150 150 150 150 60 60 — — — — — — — 60 75 75 100 150 150 200 250 300 350 450 600 600 — — — — Wye-Delta (60 Hz) 200V 230V 460V 575V 78 [Hp] [Hp] [Hp] [Hp] 60 75 100 125 150 200 250 250 350 450 500 700 700 — — 150 150 200 250 350 450 500 600 700 800 1000 1250 1500 — — — 150 200 250 300 450 500 600 700 800 1000 1250 1750 1750 — — — Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100/104-E, 100S-E Coil Type: 116 146 190 205 265 305 370 400 460 580 750 860 1060 1260 2050 2650 Electronic X X X X X X X X X X X X X X X X [A] [A] [A] [A] [Hp] [Hp] [Hp] [Hp] 54 54 TBD TBD — — — — — — — — — — — — 54 54 TBD TBD — — — — — — — — — — — — 54 54 TBD TBD — — — — — — — — — — — — 54 54 TBD TBD — — — — — — — — — — — — 15 15 TBD TBD — — — — — — — — — — — — 20 20 TBD TBD — — — — — — — — — — — — 40 40 TBD TBD — — — — — — — — — — — — 50 50 TBD TBD — — — — — — — — — — — — [A] [A] [A] [A] [A] 116 160 200 250 300 350 520 — — — — — — — — — 700 960 1200 1500 1800 2100 3120 — — — — — — — — — 580 800 1000 1250 1500 1750 2600 — — — — — — — — — 470 640 800 1000 1200 1400 2080 — — — — — — — — — 160 200 250 300 400 450 520 — — — — — — — — — [A] [A] [A] [A] [A] [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] [kW] 200 252 329 355 458 528 640 692 796 1004 1299 1489 1835 — — — 200 252 329 355 458 528 640 692 796 1004 1299 1489 1835 — — — 200 252 329 355 458 528 640 692 796 1004 1299 1489 1835 — — — 200 252 329 355 458 528 640 692 796 1004 1299 1489 1835 — — — 190 225 233 285 433 502 545 692 796 1004 1299 1385 1680 — — — 112 161 233 285 433 502 545 606 692 866 1125 1385 1680 — — — — 103 147 173 173 173 173 268 346 433 519 — — — — — 55 75 90 110 132 160 200 200 250 315 400 500 560 — — — 55 75 110 110 132 160 200 200 250 315 400 500 630 — — — 110 132 160 200 250 250 355 400 400 560 710 800 1000 — — — 110 132 160 200 250 315 355 400 400 560 800 900 1100 — — — 132 160 160 200 315 355 355 500 500 710 800 1000 1300 — — — UL/CSA Elevator Duty 200V 230V 460V 575V 200V 230V 460V 575V UL/CSA HVAC Applications Definite purpose rating (3-phase) FLA LRA 230V 460V 575V AC resistance heating 600V Star-Delta Starting (50 Hz) 230V 240V 400V 415V 500V 690V 1000V 230V (1) 240V (1) 400V (1) 415V (1) 500V (1) 690V (1) 1000V (1) 90 132 200 250 400 500 500 560 710 800 1100 1400 1700 — — — — 132 200 250 250 250 250 355 500 630 710 — — — — — (1) Power ratings at 50 Hz: Preferred values according to IEC 60947-4-1 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 79 100/104-E, 100S-E Electronic Coil Type: 116 146 190 205 265 305 370 400 460 580 750 860 1060 1260 2050 2650 X X X X X X X X X X X X X X X X 70 79 111 115 143 143 165 200 252 263 286 430 524 362 — — 70 79 111 115 143 143 165 200 252 263 286 430 524 362 — — 70 79 111 115 143 143 165 200 252 263 286 430 524 362 — — 70 79 111 115 143 143 165 200 252 263 286 430 524 362 — — 70 79 111 115 143 143 165 200 252 263 286 — — 362 — — 362 — — Switching of Power Transformers, AC-6a (50 Hz) Inrush Current =n Rated transformer current n = 30 230V [A] 240V [A] 400V [A] 415V [A] 500V [A] 690V [A] 1000V [A] 230V [kVA] 240V [kVA] 400V [kVA] 415V [kVA] 500V [kVA] 690V [kVA] 1000V [kVA] 690V [A] 690V [A] 70 79 111 115 143 143 165 200 252 263 286 — — — — — — — — — — — — — — — 28 31 44 46 57 57 66 80 100 105 114 171 209 29 33 46 48 59 59 69 83 105 109 119 179 218 48 55 77 80 99 99 114 139 175 182 198 298 363 251 — — 50 56 79 82 102 102 117 142 179 187 203 305 372 257 — — 61 68 96 100 124 124 143 173 218 228 248 — — 314 — — 84 94 133 137 171 171 197 239 301 314 342 — — 433 — — — — 144 — — 150 — — — — — — — — — — — — — — — — — — 105 119 167 173 215 215 248 300 378 395 429 — — 543 — — 140 158 222 230 286 286 330 400 504 526 572 — — 724 — — 60 Hz Peak Inrush/peak rated transformer current n = 30 660V [A] 70 79 111 115 143 143 165 200 252 263 286 430 524 362 — — 24 27 38 40 50 50 57 69 87 91 99 149 182 125 — — 25 28 40 41 52 52 59 72 91 95 103 155 189 130 — — 29 33 46 48 59 59 69 83 105 109 119 179 218 150 — — 58 66 92 96 119 119 137 166 210 219 238 357 436 301 — — 73 82 115 120 149 149 171 208 262 273 297 447 545 376 — — 80 90 127 131 163 163 189 229 288 301 327 492 599 414 — — 105 119 167 173 215 215 248 300 378 395 429 645 786 543 — — 36 41 58 60 74 74 86 104 131 137 149 223 272 188 — — 38 43 60 62 77 77 89 108 136 142 155 232 283 196 — — 44 49 69 72 89 89 103 125 157 164 178 268 327 226 — — n = 20 n = 15 200V 208V 240V 480V 600V 660V n = 20 660V 200V 208V 240V 480V 600V 660V n = 15 660V 200V 208V 240V 480V 600V 660V 80 [kVA] [kVA] [kVA] [kVA] [kVA] [kVA] [A] [kVA] [kVA] [kVA] [kVA] [kVA] [kVA] [A] [kVA] [kVA] [kVA] [kVA] [kVA] [kVA] 87 99 139 144 179 179 206 249 314 328 357 536 653 451 — — 109 124 174 180 223 223 258 312 393 410 446 670 817 564 — — 120 136 191 198 246 246 284 343 432 452 490 737 899 621 — — 140 158 222 230 286 286 330 400 504 526 572 860 1048 724 — — 48 55 77 80 99 99 114 139 175 182 198 298 363 251 — — 50 57 80 83 103 103 119 144 182 190 206 310 378 261 — — 58 66 92 96 119 119 137 166 210 219 238 357 436 301 — — 116 131 185 191 238 238 274 333 419 437 476 715 871 602 — — 145 164 231 239 297 297 343 416 524 547 594 894 1089 752 — — 160 181 254 263 327 327 377 457 576 601 654 983 1198 828 — — Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100/104-E, 100S-E 116 146 190 205 265 305 370 400 460 580 750 860 1060 1260 2050 2650 X X X X X X X X X X X X X X X X Switching of 3-phase Capacitors, AC-6b (50 Hz) Single capacitor 230V [kVar] 40 40 °C 240V [kVar] 40 50 60 75 85 100 110 120 140 170 220 250 300 — — — 50 60 75 85 100 110 120 140 170 220 250 300 — — — 75 90 110 130 145 165 200 210 240 285 400 450 500 — — — 75 90 110 130 145 165 200 210 240 285 400 450 500 — — — 83 110 140 160 180 210 240 260 325 350 490 550 600 — — — 80 110 135 170 200 240 280 300 325 440 600 650 800 — — — Electronic Coil Type: 400V 415V 500V 690V 1000V Single capacitor 55 °C 230V 240V 400V 415V 500V 690V 1000V Single capacitor 70 °C 230V 240V 400V 415V 500V 690V 1000V 60 Hz Single Capacitor Single capacitor 40 °C 100 140 150 155 160 170 250 300 350 450 — — — — — 50 60 75 85 100 110 120 140 170 220 250 300 — — — 40 50 60 75 85 100 110 120 140 170 220 250 300 — — — 75 90 110 130 145 165 200 210 240 285 400 450 500 — — — 75 90 110 130 145 165 200 210 240 285 400 450 500 — — — 83 110 140 160 180 210 240 260 325 350 490 550 600 — — — 80 110 135 170 200 240 280 300 325 440 600 650 800 — — — — 100 140 150 155 160 170 250 300 350 450 — — — — — 35 42 45 57 70 85 100 105 120 160 190 230 280 — — — 35 42 45 57 70 85 100 105 120 160 190 230 280 — — — 65 74 83 105 135 155 180 195 225 275 370 430 480 — — — 65 74 83 105 135 155 180 195 225 275 370 430 480 — — — 78 96 102 130 165 196 220 241 300 340 435 530 570 — — — 75 110 135 160 200 240 260 300 325 440 600 630 750 — — — — 95 120 130 140 150 160 220 270 300 400 — — — — — 33 41.569 50 66.683 83 100 125.05 114 137 171 205 — 346 — — — 38 47.804 57 76.686 95 115 143.81 131 157 196 236 — 398 — — — 75 100 125 150 200 250 300 274 329 411 494 — 832 — — — 600V 100 125 150 200 250 300 350 343 410 514 618 — 1040 — — — open [A] 116 146 190 205 265 305 370 400 460 580 750 877 1072 812 1332 1722 230/240V [A] [A] UL Ballast Ratings Filament AC-5b 40 [kVar] [kVar] [kVar] [kVar] 200V 230V 460V Switching of Lamps Gas discharge lamps AC-5a [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] 160 200 250 300 400 450 520 — — — — — — — — — 116 146 190 205 265 305 370 400 460 580 750 877 1072 812 1332 1722 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 81 100/104-E, 100S-E Electronic Coil Type: 116 146 190 205 265 305 370 400 460 580 750 860 X X X X X X X X X X X X X X X X 250 350 400 500 520 600 700 800 1050 1350 1650 1250 2050 — — Switching of DC Loads Non-inductive or slightly inductive loads or resistance furnaces DC-1 at 60 °C 1 pole 24V [A] 160 200 48/60V 110V 220V 440V 2 poles in series 24V 48/60V 110V 220V 440V [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] 1060 1260 2050 2650 160 200 250 350 400 500 520 600 700 800 1050 1350 1650 1250 2050 — — — — 400 500 520 600 700 800 1050 1250 1350 1650 2050 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 160 200 250 350 400 500 520 600 700 800 1050 1250 1350 1650 2050 — 160 200 250 350 400 500 520 600 700 800 1050 1250 1350 1650 2050 — 160 200 250 350 400 500 520 600 700 800 1050 1250 1350 1650 2050 — — — — — 400 500 520 600 700 800 1050 — — — — — — — — — — — — — — — — — — — — — 160 200 250 350 400 500 520 600 700 800 1050 1250 1350 1650 2050 — 160 200 250 350 400 500 520 600 700 800 1050 1250 1350 1650 2050 — 160 200 250 350 400 500 520 600 700 800 1050 1250 1350 1650 2050 — 160 200 250 350 400 500 520 600 700 800 1050 1250 1350 1650 2050 — — — — — — — — 600 700 800 1050 1250 1350 1650 2050 — Shunt-wound Motors—Starting, reverse current breaking, reversing, stepping DC-3, 60 °C 3 poles in series 24V [A] 145 160 250 275 3 poles in series 24V 48/60V 110V 220V 440V 350 400 450 600 700 800 1050 — — — — — 145 160 250 275 350 400 450 600 700 800 1050 — — — — — 145 160 250 275 350 400 450 600 700 800 1050 — — — — — 145 160 250 275 350 400 450 600 700 800 1050 — — — — — — — — — — — — 600 700 800 1050 — — — — — Series-wound Motors—Starting, reverse current breaking, reversing, stepping DC-5, 60 °C 3 poles in series 24V [A] 145 160 250 275 48/60V 110V 220V 440V 48/60V 110V 220V 440V [A] [A] [A] [A] 350 400 450 600 700 800 1050 — — — — — [A] [A] [A] [A] 145 160 250 275 350 400 450 600 700 800 1050 — — — — — 145 160 250 275 350 400 450 600 700 800 1050 — — — — — 145 160 250 275 350 400 450 600 700 800 1050 — — — — — — — — — — — — 600 700 800 1050 — — — — — [A] [A] [A] [A] [A] 1300 1460 1900 2050 2650 3050 3700 4600 4600 7000 7000 10000 12000 8000 12000 12000 928 1168 1520 1640 2120 2440 2960 4400 4400 6400 6400 8000 10000 7200 10000 10000 536 674 878 947 1224 1409 1709 3100 3100 4500 4500 6000 7500 5200 7500 7500 379 477 621 670 865 996 1208 2500 2500 3500 3500 4500 5500 4000 5500 5500 160 225 275 350 400 500 600 840 840 1300 1300 1600 2200 1500 2200 2800 Short Time Withstand ICW 40 °C 1s 10 s 30 s 1 min 15 min Resistance and Power Dissipation Main current circuit resistance Power dissipation per pole at Ie AC-1, 400V Power dissipation per pole at Ie AC-3/400V [mΩ] 0.469 0.454 0.198 0.204 0.200 0.200 0.200 0.083 0.086 0.050 0.045 0.044 0.029 0.050 0.030 0.028 23 15 25 32 50 72 30 42 32 50 80 80 80 125 200 [W] 12 10 7 8 14 19 27 16 21 17 28 50 50 — — — [W] 6 Total power dissipation at: Ie AC-3, 400V; AC/DC control (120-250V) [W] 21 33 23.5 26.5 46.5 61.5 85.5 53 68 56 89 171 171 — — — Maximum Switching Frequency AC-1 AC-3 AC-2, AC-4 ops /hr ops /hr ops /hr 300 300 60 300 60 15 300 300 60 — — — 150 60 60 — — — Weight AC/DC (Electronic) with bar connections with built-in cable clamps kg 1.50 (lbs.) (3.3) 82 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 1.50 (3.3) 3 (6.6) 3 (6.6) kg 1.75 1.75 (lbs.) (3.85) (3.85) — — 4.64 4.64 4.64 12 12 (10.2) (10.2) (10.2) (26.4) (26.4) — — — — — 15 (33) 15 (33) 34 (74.8) 35 (77) 16 (35.2) 35 (77) 45 (99) — — — — — — — 100/104-E, 100S-E 116 146 190 205 265 305 370 400 460 580 750 860 1060 1260 2050 2650 X X X X X X X X X X X X X X X X 800 1000 1250 — — — 800 1000 1600 — — — 1000 1600 1600 — — — Short Circuit Current Rating (Max. Fuse or Circuit Breaker Rating) Per UL 60947 and CSA 22.2 No. 14 (contactor and fuses or circuit breaker only) 10 kA Available Fault Current UL Class RK5 Fuses — — — — — — — — Type 1 Combination (600V) [A] 250 250 400 400 — — — — Electronic Coil Type: Short Circuit Coordination (Max. Fuse or Circuit Breaker Rating) Per IEC 60947-4-1 100 kA Available Fault Current DIN Fuses gG MCCB Type "2" (400V) [A] 250 250 315 315 400 500 630 Type "2" (690V) [A] 160 200 315 315 400 425 500 630 630 800 80 kA Available Fault Current 500 630 800 70 kA Available Fault Current Type "2" (400V) [A] 160 160 320 320 400 630 630 630 630 800 18 kA Available Fault Current Type 1 Combination (600V) UL Class L Fuses [A] — — — — 800 800 800 1000 — — — — — — — — — — — — — — — 1600 1600 — — — 30 kA Available Fault Current Type 1 Combination (600V) [A] — — — — — — — Type 1 Combination (600V) [A] — — — — — — — — 1000 — 85 kA Available Fault Current UL Class J Type 1 Combination (600V) and CSA HRCI-J Fuses Type 2 Combination (600V) UL Class L Fuses — — — 100 kA Available Fault Current [A] 250 [A] 200 250 400 400 600 600 600 600 600 — — — — — — — 200 400 400 600 600 600 600 600 — — — — — — — — — — — — — — 800 800 1200 1200 — — 1600 — — Type 2 Combination (600V) [A] [A] — — — — — — — — — 1200 1200 — — — — — Type 1 Combination (480V) [A] — — — — — — — 1200 — — — — — Type 2 Combination (480V) [A] 250 250 400 400 800 800 800 800 — — — — — — — — — — — 800 — — — — — — — — — — — — — — — — — 800 — — — — — 800 — — — — — — — — — — — — — — — — — 100 kA Available Fault Current Type 1 Combination (600V) 42 kA Available Fault Current — — 1200 65 kA Available Fault Current 800 800 800 84 kA Available Fault Current Type 1 Combination (480V) [A] — — — — — — — 800 800 — 89 kA Available Fault Current [A] — — — — — — — UL Inverse- Type 1 Combination (480V) Time Circuit [A] 250 250 400 400 800 800 800 Type 2 Combination (600V) [A] 250 Type 1 Combination (480V) — — 800 100 kA Available Fault Current — — — 25 kA Available Fault Current 250 — — — — — — — — 35 kA Available Fault Current Type 2 Combination (600V) [A] — — 400 400 800 800 800 800 800 800 42 kA Available Fault Current Type 1 Combination (600V) [A] — — — — 800 800 800 800 800 800 50 kA Available Fault Current Type 1 Combination (600V) [A] 250 250 — — — — — Type 1 Combination (600V) [A] — 400 400 400 400 400 — — — 65 kA Available Fault Current — — — — Rockwell Automation Publication 100-TD013F-EN-P - November 2017 83 Coil Data 100-E, 100S-E Electronic Coil Type: 116 146 190 205 265 305 370 400 460 580 750 860 1060 1260 X X X X X X X X X X X X X X 2050 2650 X X Operating Limits 50/60 Hz DC control 24…60V AC 48…130V AC 100…250V AC 250…500V AC 24…60V DC 48…130V DC 100…250V DC 250…500V DC pick-up [x Us] 0.85…1.1 dropout [x Us] 0.55 0.80…1.1 pick-up [x Us] dropout [x Us] pick-up [VA] [VA] [VA] [VA] [VA] [VA] [VA] [VA] [W] [W] [W] [W] [W] [W] [W] [W] 225 165 475 — — — — — 5.5 6 8.5 — — — — — 170 175 340 1215 1100 — 1100 — 4 4 17 12 12 — 12 — 130 220 385 955 880 2450 880 2450 6 7 17.5 12 12 48 12 48 205 185 420 950 985 — 985 — 16 16 21 12 12 — 12 210 205 400 900 785 — 785 — — 2.5 2.5 3.5 5 5.5 — 5.5 — — 130 130 360 1150 1020 — 1020 — — 2.5 2.5 2.5 5 5 — 5 — — 135 190 410 895 880 2290 880 2290 3 2.5 4.5 5 5 20.5 5 20.5 205 190 600 885 910 — 910 — — 4 4 4.7 7.5 7.5 — 7.5 — — [ms] [ms] [ms] [ms] 20…55 25…60 30…60 50…120 50…120 50…80 50…120 50…80 40…70 45…80 45…80 33…70 33…70 35…55 33…70 35…55 20…31 25…45 25…45 40…60 40…90 40…65 40…90 40…65 24…34 25…45 25…45 10…30 10…30 10…30 10…30 10…30 hold-in pick-up hold-in pick-up hold-in pick-up hold-in pick-up hold-in pick-up hold-in pick-up hold-in pick-up hold-in 0.55 — Operating Times AC or DC With PLC Interface 84 closing delay opening delay closing delay opening delay Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Cross Sections, Screw Type Terminals (1) conductor Clamp Type Recommended torque (2) conductors Clamp Type Recommended torque (3) conductors Clamp Type Recommended torque (4) conductors Clamp Type Recommended torque (6) conductors Clamp Type Recommended torque L max. L Ø Ø min. Recommended torque Cross section per UL/CSA (1) conductor Clamp Type Recommended torque (2) conductors Clamp Type Recommended torque (3) conductors Clamp Type Recommended torque (4) conductors Clamp Type Recommended torque (6) conductors Clamp Type Recommended torque L max. L Ø min. Ø Recommended torque [mm2] [N•m] [mm2] [N•m] [mm2] [N•m] [mm2] [N•m] [mm2] [N•m] [mm] [mm] [N•m] [AWG] [lb-in] [AWG] [lb-in] [AWG] [lb-in] [AWG] [lb-in] [AWG] [lb-in] [in] [in] [lb-in] 3 265 305 370 X X X 19.5 Ø 8.5 5 Ø 10.5 5 400 X 460 X 750 X 860 X 6 Ø 6.5 Ø 12.5 1060 X 6 — — — 70…500 100-ETL750 43 70…500 100-ETL750 43 — — — — — — 50 12 45 Ø 13 1260 X 2050 X 10 — — — Ø 13 2650 X 80 40 50 27 80 40 27 40 22.5 25 22.5 Ø 10.5 Ø 6.5 580 X 40 17 7 Ø 6.5 205 X 17.5 13 Conductor Cross Sections — Main Contacts (Terminal type) 190 X 25 15.5 146 X 10 30 17 116 X 14.3 Electronic 10 100-E, 100S-E Coil Type: Main Terminals 8 Ø 13 (AF2050) 10 (AF2650) 25 10…95 100-ECL146 8 10…95 100-ECL146 8 — — — — — — — — — 22 6 9 16…300 100-ETL205 34 — — — — — — — — — — — — 24 8 18 16…400 100-ETL370 42 16…500 100-ETL370B 42 — — — — — — — — — 32 10 28 — — — 70…500 100-ETL580 31 — — — — — — — — — 47 10 35 — — — — — — 70…500 100-ETL750 43 — — — — — — 50 12 45 — — — — — — — — — — — — — — — 100 12 45 3…3/0 100-ECL146 80 6…3/0 100-ECL146 80 — — — — — — — — — 0.866 0.236 80 6…300 (1) 100-ETL205 300 — — — — — — — — — — — — 0.945 0.315 160 4…400 (1) 100-ETL370 375 4…500 (1) 100-ETL370B 375 — — — — — — — — — 1.26 0.394 248 — — — — — — — — — — — — — — — 2/0…500 (1) 2/0…500 (1) 4/0…500 (1) 1/0…750 (1) 2/0…500 (1) 100-ETL580 100-ETL750 100-ETL860 100-ETL1060 100-ETL750 275 375 375 500 375 — 2/0…500 (1) 4/0…500 (1) 1/0…750 (1) 2/0…500 (1) — 100-ETL750 100-ETL860 100-ETL1060 100-ETL750 — 375 375 500 375 — — 4/0…500 (1) 1/0…750 (1) — — — 100-ETL860 100-ETL1060 — — — 375 500 — — — — 1/0…750 (1) — — — — 100-ETL1060B — — — — 500 — 1.85 1.97 3.94 1.97 0.394 0.472 0.472 0.472 310 398 398 398 — — — — — — — — — — — — — — — 3.94 0.472 398 120…500 100-ETL860 43 120…500 100-ETL860 43 120…500 100-ETL860 43 — — — Rockwell Automation Publication 100-TD013F-EN-P - November 2017 70…750 100-ETL1060 57 70…750 100-ETL1060 57 70…750 100-ETL1060 57 70…750 100-ETL1060B 57 100 12 45 85 100-E, 100S-E 116 146 190 205 265 305 370 400 460 580 750 860 Conductor Cross Sections — Coil Terminals (Terminal type) (1) conductor (2) conductors (1) conductor (2) conductors Recommended torque Cross section per UL/CSA Recommended torque [mm2] [mm2] [mm2] [mm2] 0.75…2.5 0.75…2.5 1…4 [N•m] [AWG] [lb-in] 1…1.2 18…14 8.9…10.6 1…4 (1) MCM Auxiliary contact for 100/104-E, 100S-E Standard 100-ES1/2* Standard 100-ES3/4* Low Power 100-ES*-B* Switching of AC Loads Rated Insulation voltage Ui Rated operational voltage Ue Rated impulse withstand voltage Uimp AC-12 Ith 690V 690V 6kV at 40 °C at 60 °C 24V AC-14 at rated voltage of 42/48V 120V 24V 42/48V 120V 230V AC-15 at rated voltage of 240V 400V 415V 500V 690V [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] 690V 690V 6kV 250V 125V 1.5kV 16 16 0.1 — — — — — 0.1 — — 0.1 — — 0.1 6 6 — 6 6 — 6 6 — 4 4 — 4 4 — 3 3 — 3 3 — 2 2 — 2 2 — — — 0.1 — — 0.1 — — 0.1 — — — — — — — — — — — — — — — — — — — — — 3 6 — 1.5 2.8 — 0.55 0.55 — 0.3 0.3 — Switching of DC Loads 24V DC 48V DC DC-12 L/R< 1 ms resistive loads at 110V DC 220V DC 440V DC 24V DC DC-14 L/R< 15 ms inductive loads with economy resistor in series at 48V DC 110V DC 220V DC 440V DC 24V DC 48V DC DC-13 switching electromagnets at 110V DC 220V DC 440V DC [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] — Fuse gG Short-circuit protection with no welding of contacts per IEC 60947-5-2 86 [A] [A] 10 10 0.1 10 10 0.1 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 1060 1260 2050 2650 Auxiliary contact for 100/104-E, 100S-E Standard 100-ES1/2* Standard 100-ES3/4* Low Power 100-ES*-B* Protective Separation per IEC 60947-1, Annex N [mA] [mA] Min. switching capacity at 24V IEC 60947-5-4 Min. switching capacity at 3V IEC 60947-5-4 50 50 — — — 1 600 600 125 10 10 0.1 A 600 A 600 — 250 250 125 Load Carrying Capacity per UL/CSA Rated voltage [V] [A] AC Continuous rating 40 °C Switching capacity AC Rated voltage DC Continuous rating 40 °C Switching capacity DC [V] [A] 2.5 2.5 0.1 P 600 Q 300 — Life-Load Curves 3-pole contactors — Electrical durability Figure 21 - Electrical durability for AC-1 utilization category - Ue ≤ 690V Switching non-inductive or slightly inductive loads. The breaking current Ic for AC-1 is equal to the rated operational current of the load. 80 E7 50 E5 00 60 E4 E4 70 05 E3 65 E3 05 E2 90 E2 46 E1 E1 E1 16 Ambient temperature (see page 76) and maximum electrical switching frequency (see page 82). 10 5 Millions of operating cycles 3 2 9 7 5 3 1 9 7 5 3 1 1 0.5 0.3 9 7 5 3 1 0.2 1 3 5 7 9 0.1 1 2 3 5 10 3 5 7 9 20 1 1 5 9 1 30 50 100 3 5 7 3 5 7 9 1 3 579 9 200 300 1 5 9 500 1000 Breaking current Ic (A) Cat. Nos. 100-E860, -E1060: The electrical durability at the rated current is 50,000 operating cycles. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 87 Figure 22 - Electrical durability for AC-3 utilization category - Ue ≤ 440V Switching cage motors: starting and switching off running motors. The breaking current Ic for AC-3 is equal to the rated operational current Ie (Ie = motor full load current). 0 0 E7 5 E5 8 E4 00 E4 60 E2 05 E2 65 E3 05 E3 70 6 0 19 E1 4 E1 1 6 For ambient temperature (see page 76) and maximum electrical switching frequency (see page 82). 10 Millions of operating cycles 5 3 2 9 7 5 3 1 9 7 5 3 1 1 0.5 1 3 5 7 9 0.3 1 3 5 7 9 1 3 5 7 9 1 0.2 2 3 5 10 20 30 1 1 5 9 5 9 50 1 100 3 5 7 3 5 7 9 1 3 579 9 200 300 Breaking current Ic (A) Cat. Nos. 100-E860, -E1060: The electrical durability at the rated current is 50,000 operating cycles. 88 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 500 1000 Figure 23 - Electrical durability for AC-3 utilization category - 440V < Ue ≤ 690V Switching cage motors: starting and switching off running motors. The breaking current Ic for AC-3 is equal to the rated operational current Ie (Ie = motor full load current). 50 80 E7 E5 60 70 E4 E3 00 E4 05 65 E3 05 E2 90 E2 46 E1 E1 E1 16 For ambient temperature (see page 76) and maximum electrical switching frequency (see page 82). 10 Millions of operating cycles 5 3 2 9 7 5 3 1 9 7 1.5 5 3 1 1 0.5 1 1 3 5 7 9 0.3 1 1 3 5 7 9 0.2 2 3 5 10 3 5 7 9 20 1 1 3 579 30 1 5 9 50 100 3 5 140 7 3 5 7 9 1 3 579 9 200 300 500 1000 Breaking current Ic (A) Cat. Nos. 100-E860, -E1060: The electrical durability at the rated current is 50,000 operating cycles. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 89 Figure 24 - Electrical durability for AC-2 or AC-4 utilization category - Ue ≤ 440V Switching cage motors: starting, reverse operation and step-by-step operation. The breaking current Ic is equal to 2.5 x Ie for AC-2 and 6 x Ie for AC-4, E2 0 05 E2 6 E3 5 0 E3 5 70 E4 0 0 E4 60 E5 80 E7 50 E1 9 E1 1 6, E1 4 6 keeping in mind that Ie is the motor rated operational current (Ie = motor full-load current). For maximum electrical switching frequency (see page 82). 10 5 3 2 9 7 5 3 1 Millions of operating cycles 1 0.5 0.3 0.2 9 7 5 3 1 0.1 0.05 0.03 0.02 9 7 5 3 1 0.01 1 3 5 7 9 1 0.005 2 3 5 10 3 5 7 1 3 5 7 9 9 20 1 30 50 3 100 5 7 9 200 1 300 500 Breaking current Ic (A) 90 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 1000 3 5 7 9 2000 3000 5000 Figure 25 - Electrical durability for AC-2 or AC-4 utilization category - 440V < Ue ≤ 690V E4 E4 00 60 E5 8 E7 0 50 E1 E1 16 46 E1 90 E2 0 E 5 E3 265 0 E3 5 70 Switching cage motors: starting, reverse operation and step-by-step operation. The breaking current Ic is equal to 2.5 x Ie for AC-2 and 6 x Ie for AC-4, keeping in mind that Ie is the motor rated operational current (Ie = motor full load current). For maximum electrical switching frequency (see page 82). 10 5 3 2 9 7 5 3 1 Millions of operating cycles 1 0.5 0.3 0.2 9 7 5 3 1 0.1 0.05 0.03 0.02 9 7 5 3 1 0.01 1 1 3 5 7 3 5 7 9 9 1 3 5 7 9 1 3 5 7 9 0.005 2 3 5 10 20 30 50 100 200 300 500 1000 2000 3000 5000 Breaking current Ic (A) Rockwell Automation Publication 100-TD013F-EN-P - November 2017 91 Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. 90 (3.54) 30 (1.18) 90 (3.54) 92 100 (3.94) 19.5 (0.77) 55.5 (2.18) 100-E116E*, 100-E146E* 35.5 (1.40) 152 (5.98) 5 (0.20) 35 (1.36) 165 (6.50) 83.5 (3.29) ø 8.5 (0.33) 29.5 (1.16) 150 (5.91) 196 (7.72) 35 (1.38) 30 (1.18) M4 (8-32 UNC) 142.5 (5.61) 30 (1.18) 105 (4.13) 100 (3.94) 100-E116K*, 100-E146K* D 10 (0.39) 19.5 (0.77) 150 (5.91) D 10 (0.39) 30 (1.18) M4 (8-32 UNC) 126 (4.96) 55.5 (2.18) 10 (0.39) 100-E190, 100-E205 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 M5 (10-24 UNC) 35.5 (1.40) ø 8.5 (0.33) 35 (1.36) 100-E190E, 100-E205E 180 (7.09) 140 (5.51) ø 10.5 (0.41) 5 (0.20) 43.75 (1.72) M5 (10-24 UNC) 187 (7.36) 225 (8.86) 195.5 (7.70) 187 (7.36) ø 10.5 (0.41) 5 (0.20) 33.4 (1.31) 35.5 (1.40) 94.7 (3.73) 225 (8.86) 43.75 (1.72) M5 (10-24 UNC) 100-E265…100-E370 140 (5.51) 19.5 (0.77) 43.75 (1.72) 33.4 (1.31) 35.5 (1.40) 94.7 (3.73) 19.5 (0.77) 43.75 (1.72) 10 (0.39) M5 (10-24 UNC) 165 (6.50) 35 (1.38) 10 (0.39) 169.5 (6.67) 5 (0.20) 29.5 (1.16) 83.5 (3.29) 105 (4.13) 196 (7.72) 10 (0.39) 100-E265E…100-E370E Rockwell Automation Publication 100-TD013F-EN-P - November 2017 93 186 (7.32) 22.5 (0.89) ø 6.5 (0.26) ø 10.5 (0.41) 48.5 (1.91) 216 (8.5) 6 (0.24) 63 (2.48) 248 (9.76) 278 (10.94) 268 (10.55) 11.5 (0.45) 25(0.98) M5 (10-24 UNC) 63 (2.48) 210 (8.27) 22.5 (0.89) ø 6.5 (0.26) 242 (9.53) ø 12.5 (0.49) 48.5 (1.91) 6 (0.24) 72 (2.83) 249 (9.8) 283 (11.14) 273 (10.75) 11.5 (0.45) 40 (1.57) 100-E400, 100-E460 M6 (1/4-20 UNC) 72 (2.83) 100-E580…100-E750 50 (1.97) 27 72 (2.83) ø7 (0.28) 242 (9.53) 249 (9.8) 249 (9.8) 263 (10.35) 313 (12.32) 344 (13.54) 72 (2.83) M6 (1/4-20 UNC) ø7 (0.28) 94 72 (2.83) 72 (2.83) 210 (8.27) 46.5 (18.3) 8 (0.31) 100-E1260 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 40 (1.57) 27 (1.06) 13 (0.51) (1.57) 17 (0.67) 17 (0.67) 30 (1.18) 40 (1.57) 10 (0.39) E860, E1060 E860, E1060, E2050 392 (15.43 47 (1.85) 10 (0.39) 40 ø 13 (0.51) A B C E2050, E2650 136 (5.35) 136 (5.35) 244 (9.61) C 136 (5.35) A 312 (12.3) 312 (12.28) B 136 (5.35) ø 9 (0.35) 40 (1.57) 80 (3.15) 101 (3.98) E2650 422 (16.61 53(2.09) 25 (0.98) M8 (5/16-18 UMC) 438 (17.24) 100-E860, 100-E1060, 100-E2050, 100-E2650 Mounting Position Figure 26 - 100-E116…100-E2650 — AC/DC and AC/DC with PLC input 0° 12 18 0° 18 0° 30° Rockwell Automation Publication 100-TD013F-EN-P - November 2017 95 Accessories Description Connection Diagrams N.O. NC 21 NO 44 NO 14 NC 22 1 NO 43 NC 31 NO 53 NC 61 NO 84 NC 72 1 NC 32 1 Standard Auxiliary Contact Cat. No. N.C. NO 13 Auxiliary Contact Blocks for Side Mounting with Sequence Terminal Designations • 2-pole • Two-way numbering for right or left mounting on the contactor • Quick and easy mounting without tools • Mirror contact performance to the main contactor poles • Low power switching down to 24V 50 mA For Use With NO 54 NC 62 1 100-E116…E370, left or right inside mounting 100-E116…E370, left or right outside mounting 100-ES1-11 100-ES2-11 NO 83 NC 71 NO 17 NO 28 1 0 NO 18 100-E116…E370, left or right inside mounting 100-ES1-B10 100-E116…E370, left or right inside mounting 100-ES1-B01 100-E400…E2650, left or right inside mounting 100-ES3-11 100-E400…E2650, left or right outside mounting 100-ES4-11 100-E400…E2650, left or right inside mounting 100-ES3-B10 100-E400…E2650, left or right inside mounting 100-ES3-B01 NO 27 NC 15 NC 26 Low Power Auxiliary Contact Blocks for Side Mounting with Sequence Terminal Designations (1) • 1-pole • Two-way numbering for right or left mounting on the contactor • Quick and easy mounting without tools • Mirror contact performance to the main contactor poles • Electronic compatible, 3V 1 mA 0 1 NC 16 NC 25 NC 21 NO 13 NO 14 NC 22 1 NO 43 NC 31 NO 53 NC 61 NO 84 NC 72 1 NO 44 1 NC 32 Auxiliary Contact Blocks for Side Mounting with Sequence Terminal Designations • 2-pole • Two-way numbering for right or left mounting on the contactor • Quick and easy mounting without tools • Mirror contact performance to the main contactor poles • Low power switching down to 24V 50 mA NO 54 NC 62 1 NO 83 NC 71 NO 17 NO 28 1 0 NO 18 NO 27 NC 15 NC 26 Low Power Auxiliary Contact Blocks for Side Mounting with Sequence Terminal Designations (1) • 1-pole • Two-way numbering for right or left mounting on the contactor • Quick and easy mounting without tools • Mirror contact performance to the main contactor poles • Electronic compatible, 3V 1 mA 0 1 NC 16 NC 25 (1) No auxiliary contacts blocks can be mounted on the outside of the 100-ES1-10-B* or 100-ES3-B*. Description Mechanical Interlocks • For interlocking of two contactors. • Interlocking of different sizes possible Connection Diagrams Mechanical only, without auxiliary contacts For Use With 100-E116...100-E146 100-E190...100-E205 100-E265...100-E370 100-E116...100-E146 to 100-E190...100-E205 100-E190...100-E205 to 100-E265...100-E370 100-E400…100-E750, 100-E1260 (1) 100-E860…100-E1060, 100-E2050…100-E2650 (2) Rod for vertical mounting 100-E400…E750 reversing contactors (1) Mounting plate ordered separately (2) Mounting plate included 96 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Cat. No. 100-EM1-00 100-EM4-00 100-EM5-00 100-EM2-00 100-EM3-00 100-EVR750 Description Wire Sizes For Use With Cat. No. 2 x 6 AWG…3/0 AWG 100-E116…100-E146 100-ECL146 4 AWG…300 MCM 4 AWG…400 MCM (2x) 4 AWG…500 MCM (2x) 2/0 AWG…500 MCM (3x) 2/0 AWG…500 MCM (4x) 4/0 AWG…500 MCM (4x) 1/0 AWG…750 MCM (6x) 1/0 AWG…750 MCM 100-E190…100-E205 100-E265…100-E370 100-E265…100-E370 100-E400…100-E460 100-E580...E750, 100-E1260 100-E860 100-E1060 100-E1060 100-ETL205 100-ETL370 100-ETL370B 100-ETL580 100-ETL750 100-ETL860 100-ETL1060 100-ETL1060B For Use With Cat. No. 100-E116…100-E146 100-E190…100-E205 100-E190…100-E205 100-E265…100-E370 100-E265…100-E370 100-E400…100-E460 100-E400…100-E460 100-E580…100-E750 100-E580…100-E750, 100-E1260 100-E116…100-E146 100-E190…100-E205 100-E116…100-E146 100-E190…100-E205 100-ETS146L 100-ETS205L 100-ETS205C 100-ETS370L 100-ETS370C 100-ETS460L 100-ETS460C 100-ETS750L 100-ETS750C 100-ETC146 100-ETC205 100-ETCR146 100-ETCR205 Terminal Lug Kit • Standard on 100-E116*L…100-E146*L contactors Terminal Lugs Description Contactor with Terminal Lugs Wires with Compression Lugs X X X X Terminal Shrouds X X X X X IP20 terminal shield between contactor and 193-E overload relay on an assembled direct on-line starter IP20 terminal shield between contactor and 193-E overload relay on an assembled reversing starter Description Reversing Power Wiring Kits Wye-Delta Power Wiring Kits Shorting Bars Delta Contactor 100-E116…100-E146 100-E190…100-E205 100-E190…100-E205 100-E265…100-E370 100-E265…100-E370 100-E400…100-E460 100-E580…100-E750 100-E580…100-E750 For Use With 100-E116…100-E146 100-E190…100-E205 100-E265…100-E370 100-E400…100-E460 100-E580…100-E750 Wye Contactor 100-E116…100-E146 100-E116…100-E146 100-E190…100-E205 100-E190…100-E205 100-E265…100-E370 100-E400…100-E460 100-E400…100-E460 100-E580…100-E750 100-E116…100-E146 100-E190…100-E205 100-E265…100-E370 100-E400…100-E460 100-E580…100-E750 Cat. No. 105-PW146 105-PW205 (1) 105-PW370 (1) 105-PW460 (2) 105-PW750 (2) Cat. No. 170-PW146 170-PW190 170-PW205 170-PW265 170-PW370 170-PW460 170-PW580 170-PW750 170-PWY146 170-PWY205 170-PWY370 170-PWY460 170-PWY750 (1) Kits includes one set of terminal extensions. If 100-ETL* terminal lugs are to be used on line and load side of reversing contactor, and second set of 100-ETX terminal extensions is required. (2) If 100-ETL* terminal lugs are to be used on line and load side of reversing contactor, two sets of 100-ETX terminal extensions are also required. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 97 Description For Use With 100-E116…100-E146 100-E190…100-E205 100-E116…100-E146 100-E190…100-E205 100-E265…100-E370 100-E400…100-E460 100-E580…100-E750 100-E116…100-E146 100-E190…100-E205 Cat. No. 100-EMS146 100-EMS205 100-EMR146 100-EMR205 100-EMR370 100-EMR460 100-EMR750 100-EMRS146 100-EMRS205 For Use With Circuit Breaker 140G-H, 140MG-H 140G-I, 140MG-I 140G-J, 140MG-J 140G-J, 140MG-J 140G-K, 140MG-K 140G-M, 140MG-M For Use With Contactor 100-E116…100-E146 100-E116…100-E146 100-E116…100-E146 100-E190…100-E205 100-E265…100-E370 100-E400…100-E750 Cat. No. 100-PCE1 100-PCE2 100-PCE3 100-PCE4 100-PCE5 100-PCE6 140G-K, 140MG-K 100-E400…100-E750 100-PCE7 For Use With Contactor 100-E116…100-E146 100-E190…100-E205 100-E265…100-E370 100-E400…100-E460 100-E580…100-E750 100-E1260 Cat. No. 100-ETE146 100-ETE205 100-ETE370 100-ETE460 100-ETE750 100-ETE1260 For Use With Contactor 100-E116…100-E146 100-E190…100-E205 100-E265…100-E370 100-E400…100-E460 Cat. No. 100-ETX146 100-ETX205 100-ETX370 100-ETX460 100-E580…100-E750 100-ETX750 For Direct On-Line Starters For Reversing Contactors For Reversing Starters Description For Connection to 140G or 140MG • Connection between contactors/starters and molded case circuit breakers. • These connection sets are solid copper bars. Description Terminal Enlargements • Enlargement pieces designed to increase the width of the contactor terminal pads in order to allow larger connections to be mounted. Description Terminal Extensions • Extension pieces designed to extend the main terminals of contactors for combined mounting of contactors and connection sets 98 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Renewal Parts Description For Use With 100-E116 100-E146 100-E190, 100-E205 100-E190 100-E205 Coil Modules 100-E265, 100-E305, 100-E370 100-E265 100-E305 100-E370 100-E400, 100-E460 100-E580, 100-E750, 100-E1260 Voltage 24…60V AC/DC 48…130V AC/DC 100…250V AC/DC 250…500V AC/DC 100…250V AC/DC w/ PLC Interface 250…500V AC/DC w/ PLC Interface 24…60V AC/DC 48…130V AC/DC 100…250V AC/DC 250…500V AC/DC 100…250V AC/DC w/ PLC Interface 250…500V AC/DC w/ PLC Interface 24…60V AC/DC 48…130V AC/DC 100…250V AC/DC 250…500V AC/DC 100…250V AC/DC w/ PLC Interface 250…500V AC/DC w/ PLC Interface 100…250V AC/DC w/ PLC Interface 250…500V AC/DC w/ PLC Interface 24…60V AC/DC 48…130V AC/DC 100…250V AC/DC 250…500V AC/DC 100…250V AC/DC w/ PLC Interface 250…500V AC/DC w/ PLC Interface 100…250V AC/DC w/ PLC Interface 250…500V AC/DC w/ PLC Interface 100…250V AC/DC w/ PLC Interface 250…500V AC/DC w/ PLC Interface 24…60V DC 48…130V AC/DC 100…250V AC/DC 250…500V AC/DC 24…60V DC 48…130V AC/DC 100…250V AC/DC 250…500V AC/DC 100-E860, 100-E1060, 100-E2050 100…250V AC/DC 100-E2650 100…250V AC/DC Cat. No. TG913 TG914 TG915 TG916 TGE913 TGE914 TG901 TG902 TG903 TG904 TGE903 TGE904 TG905 TG906 TG907 TG908 TGE915 TGE916 TGE907 TGE908 TG909 TG910 TG911 TG912 TGE917 TGE918 TGE919 TGE920 TGE911 TGE912 THE901 THE902 THE903 THE904 TJE901 TJE902 TJE903 TJE904 TKE903 (1) TKE904 (2) TLE903 (1) TLE904 (2) (1) One set of two coils (2) Printed circuit board Rockwell Automation Publication 100-TD013F-EN-P - November 2017 99 Description Contact Kits Arc Chutes For Use With 100-E116 100-E146 100-E190 100-E205 100-E2650 100-E305 100-E370 100-E400 100-E460 100-E580 100-E750 100-E1260 100-E860 100-E1060 100-E2050 100-E2650 (1) 100-E400, 100-E460 100-E580, 100-E750, 100-E1260 100-E860, 1060, 100-E2050 100-E2650 Cat. No. 100-EA116 100-EA146 100-EA190 100-EA205 100-EA265 100-EA305 100-EA370 100-EA400 100-EA460 100-EA580 100-EA750 100-EA1260 100-EA860 100-EA1060 100-EA2050 100-EA2650 100-EC460 100-EC750 100-EC1060 100-EC2650 (1) Movable contacts only Description Terminal and Mounting Hardware Kits 100 For Use With 100-E116*L, 100-E146*L 100-E116, 100-E146 100-E190, 100-E205 100-E265, 100-E305, 100-E370 100-E400, 100-E460 100-E580, 100-E750, 100-E1260 100-E2050 100-E2650 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Cat. No. 100-EHS146 100-EHF146 100-EHF205 100-EHF370 100-EHF460 100-EHF750 100-EHF2050 100-EHF2650 100-D/104-D, 100S-D Contactors Product Selection—100-D/104-D Contactors • • • • 63…500 kW @ 400V 75…600 Hp @ 460V 100…700 Hp @ 575V Electronic and conventional coils AC & DC – Integrated PLC interface – Low power pick-up & hold-in – Wide voltage ranges • Complete range of accessories • Environmentally friendly • Compact dimensions 100-D Contactor The Bulletin 100-D/104-D contactor family, along with a wide range of common accessories and Bulletin 193 electronic overload relays, provides the most compact and flexible starter component system available. Bulletin 100S-D safety contactors were designed to address the needs of modern safety applications requiring feedback and monitoring of the energy isolating switchgear used in hazardous motion loads. The 100S-D meets these needs through its "mirror contact" design. If a power contact welds, the N.C. auxiliary contacts will not change state. This feature provides reliable indication about the open/closed status of the main power poles. In addition, the goldplated bifurcated auxiliary contacts are ideally suited for low-energy applications or feedback control circuits with multiple seriesconnected N.C. auxiliary contacts. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 101 100-D/104-D 3-Pole AC- Operated Contactors • Conventional and Electronic AC Coils • 3 Main Contacts • Non-Reversing or Reversing Rated Operational Current Ie [A] 60 °C 40 °C AC-3 (400V) AC-1 (690V) Auxiliary Contacts Ratings for switching AC motors - AC-2, AC-3 kW (50 Hz) 230V 400V 415V 500V Hp (60 Hz) 690V 1000V 200V 230V 460V Reversing Contactor 575V N.O. N.C. Cat No. Cat No. 0 1 4 100-D11500 100-D11511 — 100-D14000 100-D14000 — 100-D18000 100-D18011 — 100-D21000 100-D21011 — 100-D25000 100-D25011 — 100-D30000 100-D30011 — 100-D42000 100-D42011 — 100-D63000 100-D63011 — 100-D86000 100-D86011 — — — 104-D11524 — — 104-D14024 — — 104-D18024 — — 104-D21024 — — 104-D25024 — — 104-D30024 — — 104-D42024 — — 104-D63024 — — 104-D86024 115 250 37 63 66 80 110 63 40 40 75 100 0 1 2 140 250 45 78 82 80 111 75 40 50 100 125 1 1 180 250 55 90 90 110 90 132 110 50 60 125 210 350 63 118 125 205 200 110 60 75 150 200 250 350 80 140 150 250 250 132 75 100 200 250 300 450 90 170 160 290 300 160 100 125 250 300 420 540 132 238 250 420 425 220 150 175 350 400 630 800 200 355 355 500 500 — 200 250 500 600 860 1000 250 500 500 500 600 — 250 300 600 700 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 4 0 1 4 0 1 4 0 1 4 0 1 4 0 1 4 0 1 4 102 Non-Reversing Contactor Rockwell Automation Publication 100-TD013F-EN-P - November 2017 3-Pole DC-operated Contactors • Conventional and Electronic DC Coils • 3 Main Contacts • Non-Reversing or Reversing Rated Operational Current Ie [A] 60 °C 40 °C AC-3 AC-1 (400V) (690V) Auxiliary Contacts Ratings for switching AC motors - AC-2, AC-3 kW (50 Hz) 230V 400V 415V 500V Non-Reversing Contactor Reversing Contactor Hp (60 Hz) 690V 1000V 200V 230V 460V 575V 115 250 37 63 66 80 110 63 40 40 75 100 140 250 45 78 82 80 111 75 40 50 100 125 180 250 55 90 90 110 90 132 110 50 60 125 210 350 63 118 125 205 200 110 60 75 150 200 250 350 80 140 150 250 250 132 75 100 200 250 300 450 90 170 160 290 300 160 100 125 250 300 420 540 132 238 250 420 425 220 150 175 350 400 630 800 200 355 355 500 500 — 200 250 500 600 860 1000 250 500 500 500 600 — 250 300 600 700 N.O. N.C. Cat No. Cat No. 0 1 2 2 2 0 1 2 2 2 0 1 2 2 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 2 0 1 1/1L 4 2/2L 0 1 1/1L 4 2/2L 0 1 1/1L 4 2/2L 0 1 4 0 1 4 0 1 4 0 1 4 0 1 4 0 1 4 100-D11500 100-D11511 100-D11522L — — 100-D14000 100-D14000 100-D14022L — — 100-D18000 100-D18000 100-D18022L — — 100-D21000 100-D21011 — 100-D25000 100-D25011 — 100-D30000 100-D30011 — 100-D42000 100-D42011 — 100-D63000 100-D63011 — 100-D86000 100-D86011 — — — — 104-D11524 104-D11522L — — — 104-D14024 104-D14022L — — — 104-D18024 104-D18022L — — 104-D21024 — — 104-D25024 — — 104-D30024 — — 104-D42024 — — 104-D63024 — — 104-D86024 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 103 Coil Voltage Codes—100-D/104-D Contactors The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 60 Hz: Cat. No. 100-D11511 becomes Cat. No.100-D115D11. AC Voltages [V], Conventional Coil 100-D115...100-D180 50 Hz 60 Hz 100-D115 50/60 Hz AC Voltages [V], Conventional Coil 100-D115...100-D180 50 Hz 60 Hz 100-D115 50/60 Hz 24 K J — 48 Y X — 415 B — — 100 — — KP 440 G N — 110 D — KN 480 — B — 120 — D — 500 M — — AC Voltages [V], Electronic Coil w/ EI. Interface(1) 100-D115...100-D300 50/60 Hz 100-D420 50/60 Hz 100-D630…100-D860 50/60 Hz 24 EJ(2) — — 42…64 EY — — AC Voltages [V], Electronic Coil w/ EI. Interface (1) 100-D115...100-D300 50/60 Hz 100-D420 50/60 Hz 100-D630…100-D860 50/60 Hz 230…250 — — EA 277 — — ET 200 — — KG 550 C — — 100 — — EP 208 — H — 220…230 A — KL 24 ZJ 48 ZY 110 ZD 110…130 ED ED ED 200 — — EG 380…415 380…500 440…480 — EN — — EN — EN — EB 125 ZS 208…277 EA EA — 500 — — EM 220 ZA (1) For conventional DC coils, the pickup winding must be interconnected with the N.C. late-breaking auxiliary contact(s). DC Voltages [V], Electronic Coil w/ EI Interface (1) 100-D115...100-D300 100-D420 100-D630…100-D860 24 EZJ — — 48…72 EZY — — 110…130 200…255 EZD EZA EZD EZA ED EA (1) Signal voltage of the Cat. No. 100-D… electronic interface: nominal Ue: 24V DC/Ie: 15 mA Pickup voltage: 13.0V DC...30.2V DC , Dropout Voltage: –3.0V DC...+5.0V DC. 104 240 T A KA 600 — C — (1) Signal voltage of the Cat. No. 100-D… electronic interface: nominal Ue: 24V DC/Ie: 15 mA Pickup voltage: 13.0V DC...30.2V DC Dropout Voltage: –3.0V DC...+5.0V DC (2) Not available with 100/104-D300. DC Voltages [V], Conventional Coil 100-D115...100-D180 (1) 230 — — KF Rockwell Automation Publication 100-TD013F-EN-P - November 2017 200…220 — — EG 277 — T KT 380…400 N — — Product Selection—100S-D Safety Contactors • • • • 63…500 kW @ 400V 75…600 Hp @ 460V 100…700 Hp @ 575V Electronic and conventional coils – AC & DC – Integrated PLC interface – Low power pick-up & hold-in – Wide voltage ranges • Complete range of accessories • Environmentally friendly • Compact dimensions Bulletin 100S-D safety contactors were designed to address the needs of modern safety applications requiring feedback and monitoring of the energy isolating switchgear used in hazardous motion loads. The 100S-D meets these needs through its "mirror contact" design. If a power contact welds, the N.C. auxiliary contacts will not change state. This feature provides reliable indication about the open/closed status of the main power poles. In addition, the gold-plated bifurcated auxiliary contacts are ideally suited for low-energy applications or feedback control circuits with multiple series-connected N.C. auxiliary contacts. 3-Pole AC-Operated Contactors Rated Operational Current Ie [A] 60 °C 40 °C AC-3 (400V) 115 140 180 210 250 300 420 630 860 AC-1 (690V) 250 250 250 350 350 450 540 800 1000 (1) (2) (3) (4) Ratings for switching AC motors - AC-2, AC-3 Auxiliary Contacts kW (50 Hz)(1) Cat No.(4) Hp (60 Hz) 230V 400V 415V 500V(2) 690V 1000V 200V 230V 460V 575V N.O. N.C.(3) 37 45 55 63 80 90 132 200 250 63 78 101 118 140 170 238 355 500 66/75 82/90 100 110 150 160 250 355 500 80 80/100 90/125 205 250 290 420 500 500 111 110/132 132/160 200 250 300 425 500 600 63 75 90 110 133 160 220 — — 40 40 50 60 75 100 150 200 250 40 50 60 75 100 125 175 250 300 75 100 150 150 200 250 350 500 600 100 125 150 200 250 300 400 600 700 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 100-D11522BC 100-D14022BC 100-D18022BC 100-D21022BC 100-D25022BC 100-D30022BC 100-D42022BC 100-D63022BC 100-D86022BC Preferred values according to IEC 60072-1. Higher kW rating only applies to contactors with electronic coil. The N.C. contacts meet IEC 60947-4 Annex F requirements for mirror contact performance. The N.C. mirror contacts are wired in series or parallel and must be used as monitoring contacts with feedback to the safety circuit. If standard cross-stamped auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 100S-D11522BC becomes Cat. No. 100S-D11522C. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 105 3-Pole DC-Operated Contactors Rated Operational Current Ie [A] 60 °C (1) (2) (3) (4) (5) 106 kW (50 Hz)(1) 40 °C AC-3 AC-1 (400V) (690V) 115 250 140 250 180 250 210 350 250 350 300 450 420 540 630 800 860 1000 Auxiliary Contacts Ratings for switching AC motors - AC-2, AC-3 230V 400V 415V 37 45 55 63 80 90 132 200 250 63 78 101 118 140 170 238 355 500 66/75 75 100 110 150 160 250 355 500 500V Hp (60 Hz) 690V 80 111 80/100(2) 110/132 90/125 132/160 205 200 250 250 290 300 420 425 500 500 500 600 1000V 200V 230V 460V 575V N.O. N.C.(3) 63 75 90 110 133 160 220 — — 40 40 50 60 75 100 150 200 250 40 50 60 75 100 125 175 250 300 75 100 150 150 200 250 350 500 600 100 125 150 200 250 300 400 600 700 2 3 3 2 2 2 2 2 2 2 2/1L 2/1L 2 2 2 2 2 2 Conventional Coil Cat. No. Electronic Coil Cat No.(5) 100S-D11533LC(4) 100S-D14033LC 100S-D18033LC — — — — — — 100S-D11522BC 100S-D14022BC 100S-D18022BC 100S-D21022BC 100S-D25022BC 100S-D30022BC 100S-D42022BC 100S-D63022BC 100S-D86022BC Preferred values according to IEC 60072-1. Higher kW rating only applies to contactors with electronic coil. The N.C. contacts meet IEC 60947-4 Annex F requirements for mirror contact performance. The N.C. mirror contacts are wired in series or parallel and must be used as monitoring contacts with feedback to the safety circuit. For conventional DC coil only. The pickup winding must be interconnected with the N.C. late-breaking auxiliary contacts. If standard cross-stamped auxiliary contacts are required, remove the letter "B" before the letter "C" in the cat. no. Example: Cat. No. 100S-D11522BC becomes Cat. No. 100S-D11522C. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Coil Voltage Codes—100S-D Safety Contactors The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 60 Hz: Cat. No. 100S-D11522BC becomes Cat. No.100S-D115D22BC. AC Voltages [V], Conventional Coil 100S-D115…100S-D180 50 Hz 60 Hz 100S-D115 50/60 Hz AC Voltages [V], Conventional Coil 100S-D115...100S-D180 50 Hz 60 Hz 100S-D115 50/60 Hz 24 K J — 48 Y X — 380…400 N — — 100 — — KP 415 B — — 440 G N — AC Voltages [V], Electronic Coil w/ EI Interface(1) 100S-D115…100S-D300 50/60 Hz 100S-D420 50/60 Hz 100S-D630…100S-D860 50/60 Hz 24 EJ(2) — — 42…64 EY — — AC Voltages [V], Electronic Coil w/ EI Interface (1) 100S-D115...100S-D300 50/60 Hz 100S-D420 50/60 Hz 100S-D630…100S-D860 50/60 Hz 230…250 — — EA 277 — — ET 110 D — KN 120 — D — 480 — B — 100 — — EP 200 — — KG 500 M — — 208 — H — 550 C — — 110…130 ED ED ED 220…230 A — KL 230 — — KF 240 T A KA 277 — T KT 600 — C — 200 — — EG 380…415 380…500 440…480 — EN — — EN — EN — EB 208…277 EA EA — 200…220 — — EG 500 — — EM (1) Signal voltage of the Cat. No. 100S-D… electronic interface: nominal Ue: 24V DC/Ie: 15 mA Pickup voltage: 13.0V DC...30.2V DC Dropout Voltage: –3.0V DC...+5.0V DC (2) Not available with 100S-D300 DC Voltages [V], Conventional Coil 100S-D115…100S-D180 24 ZJ 48 ZY DC Voltages [V], Electronic Coil w/ EI Interface (1) 100S-D115...100S-D300 100S-D420 100S-D630…100S-D860 24 EZJ — — 110 ZD 125 ZS 220 ZA 48…72 EZY — — 110…130 200…255 EZD EZA EZD EZA ED EA 250 ZT (1) Signal voltage of the Cat. No. 100S-D… electronic interface: nominal Ue: 24V DC/Ie: 15 mA Pickup voltage: 13.0V DC...30.2V DC , Dropout Voltage: –3.0V DC...+5.0V DC. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 107 Specifications Coil Type: Conventional Electronic — EI Rated Operational Current, Ie ≤500V 690V 1000V 230V 240V 400V 415V 500V 690V 1000V [A] [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] [kW] Rated Operational Current, Ie ≤500V 690V 1000V 230V 240V 400V 415V 500V 690V 1000V [A] [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] [kW] Rated Operational Current, Ie 230V 240V 400V 415V 500V 690V 1000V 230V 240V 400V 415V 500V 690V 1000V [A] [A] [A] [A] [A] [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] [kW] 100/104-D,100S-D 140 140 180 180 210 250 300 X — X — — — — — X — X X X X AC-1 Active Power Load (50 Hz); Ambient temperature 40 °C 250 250 250 250 250 350 350 450 250 250 250 250 250 350 350 450 250 250 250 250 250 350 350 450 100 100 100 100 100 139 139 179 104 104 104 104 104 145 145 187 173 173 173 173 173 242 242 312 180 180 180 180 180 252 252 323 217 217 217 217 217 303 303 390 299 299 299 299 299 418 418 538 433 433 433 433 433 606 606 779 AC-1 Active Power Load (50 Hz); Ambient temperature 60 °C 210 210 210 210 210 300 300 380 210 210 210 210 210 300 300 380 210 210 210 210 210 300 300 380 84 84 84 84 84 120 120 151 87 87 87 87 87 125 125 158 145 145 145 145 145 208 208 263 151 151 151 151 151 216 216 273 182 182 182 182 182 260 260 329 251 251 251 251 251 359 359 454 364 364 364 364 364 520 520 658 Switching of 3-phase Motors; (50 Hz) Ambient temperature 60 °C, AC-2, AC-3 115 140 140 180 180 210 250 300 115 140 140 180 180 210 250 300 115 140 140 180 180 210 250 300 115(130)(1) 140(155)(1) 140(155)(1) 180(189)(1) 180(189)(1) 210(227)(1) 250(258)(1) 300(315)(1) 115 115 140 140 180 210 250 300 115 115 140 140 180 210 250 300 46 55 55 65 65 80 95 115 37 45 45 57 57 67 80 97 38 47 47 60 60 70 83 101 64 78 78 101 101 118 140 170 (1) (1) (1) (1) (1) (1) (1) 66(75) 82(90) 82(90) 105(110) 105(110) 122(132) 145(150) 176(185)§(1) 80 80 98 98 126 147 177 213 111 111 135 135 176 205 250 293 63 75 75 90 90 110 132 160 115 X X (1) 415 V: values in ( ) AC-2 and AC-3 lifespan -25 % 108 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 420 — X 630 — X 860 — X 540 540 540 199 208 346 359 433 598 866 800 800 — 319 333 554 575 693 956 — 1000 1000 — 398 416 693 719 866 1195 — 425 425 425 169 177 294 305 368 508 736 — — — — — — — — — — — — — — — — — — — — 420 420 420 420 420 420 160 135 141 238 250 298 424 225 630 630 630 630 630 492 — 200 200 355 355 450 500 — 860 860 860 860 753 — — 250 250 500 500 560 — — 100/104-D,100S-D 140 180 180 210 250 Conventional — X — — — Coil Type: Electronic — EI X — X X X Load Carrying Capacity per UL/CSA General Purpose Current (enclosed) [A] 220 220 220 220 220 300 300 115V [A] 100 135 135 — — — — 230V [A] 110 136 136 176 176 216 — Rated power (enclosed) 1-phase 115V [Hp] 10 15 15 — — — — 230V [Hp] 25 30 30 40 40 50 — 200V [A] 120 120 120 150 150 177 221 230V [A] 104 130 130 154 154 192 248 460V [A] 96 124 124 180 180 180 240 575V [A] 99 125 125 144 144 192 242 Rated power (enclosed) 3-phase 200V [Hp] 40 40 40 50 50 60 75 230V [Hp] 40 50 50 60 60 75 100 460V [Hp] 75 100 100 150 150 150 200 575V [Hp] 100 125 125 150 150 200 250 Switching of 3-phase Motors, (50 Hz); Ambient temperature 60 °C, AC-4 230V [A] 115 140 140 180 180 210 250 240V [A] 115 140 140 180 180 210 250 400V [A] 115 140 140 180 180 210 250 415V [A] 115(130)(2) 140(155)(2) 140(155)(2) 180(189)(3) 180(189)(3) 210(227)‡ 250(258)‡ 500V [A] 115 115 140 140 170 210 250 690V [A] 115 115 140 140 170 210 250 1000V [A] 46 55 55 65 65 80 95 230V [kW] 37 45 45 57 57 67 80 240V [kW] 39 47 47 60 60 70 83 400V [kW] 63 78 78 100 100 118 140 415V [kW] 66(75)(2) 82(90)(2) 82(90)(2) 105(110)(2) 105(110)(2) 125(132)(2) 145(150)(2) 500V [kW] 80 80 98 98 119 147 177 690V [kW] 110 110 135 135 167 205 250 1000V [kW] 63 75 75 90 90 110 132 AC-4 at approximately 200,000 operations 230V [A] 53 60 60 67 67 85 105 240V [A] 53 60 60 67 67 85 105 400/415V [A] 53 60 60 67 67 85 105 500V [A] 53 60 60 67 67 85 105 690V [A] 53 60 60 67 67 85 105 1000V [A] 25 37 37 43 43 60 72 230V (1) [kW] 15 17 17 20 20 25 32 240V (1) [kW] 15 18.5 18.5 22 22 25 32 400V (1) [kW] 25 32 32 37 37 45 55 415V (1) [kW] 25 32 32 37 37 50 55 500V (1) [kW] 32 40 40 45 45 55 75 690V (1) [kW] 45 55 55 63 63 80 100 1000V (1) [kW] 30 50 50 55 55 80 100 Max. switching frequency Ops/hour 120 120 120 100 100 120 100 115 X X 140 X — 300 — X 420 — X 630 — X 860 — X 340 — — — — 285 312 302 289 100 125 250 300 420 — — — — 414 420 414 382 150 175 350 400 630 — — — — 552 602 590 562 200 250 500 600 860 — — — — 692 720 702 651 250 300 600 700 300 300 300 300(315)‡ 300 300 115 97 101 170 176(185)(2) 213 293 160 420 420 420 420 360 360 160 135 141 238 250 255 356 225 — — — — — — — — — — — — — — — — — — — — — — — — — — — — 140 140 140 140 140 85 45 45 75 80 100 132 110 70 170 170 170 170 170 105 55 55 90 100 110 160 150 70 — — — — — — — — — — — — — — — — — — — — — — — — — — — — (1) Power ratings at 50 Hz: Preferred values according to IEC 60072-1 (2) 415V: Values in ( ) AC-3 and AC-4 lifespan -25% (3) Approval pending on Cat. No. 100-D210…D860. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 109 Coil Type: Conventional Electronic — EI 200V 230V 460V 575V [Hp] [Hp] [Hp] [Hp] 200V 230V 460V 575V 200V 230V 460V 575V [A] [A] [A] [A] [Hp] [Hp] [Hp] [Hp] ≤ 230V ≤ 240V 400V 415V 500V 690V 1000V 230V (1) 240V (1) 400V (1) 415V (1) 500V (1) 690V (1) 1000V(1) [A] [A] [A] [A] [A] [A] [A] [kW] [kW] [kW] [kW] [kW] [kW] [kW] 100/104-D,100S-D 140 180 180 210 250 300 — X — — — — X — X X X X Wye-Delta (60 Hz) 60 60 60 75 75 100 125 175 60 75 75 100 100 125 175 200 125 175 175 200 200 250 350 450 150 200 200 250 250 300 450 500 UL/CSA Elevator Duty 78 92 92 120 120 150 150 177 80 104 104 130 130 130 154 192 77 96 96 124 124 156 180 180 77 77 77 99 99 125 144 192 25 30 30 40 40 50 50 60 30 40 40 50 50 50 60 75 60 75 75 100 100 125 150 150 75 75 75 100 100 125 150 200 Star-Delta Starting (50 Hz) 199 242 242 312 312 364 433 520 199 242 242 312 312 364 433 520 199 242 242 312 312 364 433 520 199 (225)(2) 242(268)(2) 242 (268)(2) 312 (332)(2) 312 (332)(2) 364 (393)(2) 433 (447)(2) 520 (546)(2) 199 199 242 312 312 364 433 520 199 199 242 312 312 364 433 520 80 95 95 113 113 139 165 200 63 75 75 90 90 110 132 160 66 80 80 100 100 125 150 160 110 132 132 160 160 200 250 300 114 (132)(2) 132 (160)(2) 132 (160)(2) 160 160 220 250 315 (335)(2) 132 132 160 200 200 250 315 375 192 200 220 300 300 355 425 530 110 132 132 160 160 200 220 280 115 X X 140 X — (1) Power ratings at 50 Hz: Preferred values according to IEC 60072-1 (2) 415V: Values in () AC-3 and AC-4 lifespan -25% 110 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 420 — X 630 — X 860 — X 250 250 600 650 — — — — — — — — 221 248 240 242 75 100 200 250 — — — — — — — — — — — — — — — — 727 727 727 727 727 727 277 220 250 425 425 530 750 400 — — — — — — — — — — — — — — — — — — — — — — — — — — — — Coil Type: Conventional Electronic — EI Inrush Current Rated transformer current n= 30 n=20 n=15 115 X X 100/104-D,100S-D 140 140 180 180 210 250 X — X — — — — X — X X X Switching of Power Transformers, AC-6a (50 Hz) 300 — X 420 — X 630 — X 860 — X 125 125 125 125 125 125 125 50 52 87 90 108 149 217 188 250 150 150 150 150 150 150 150 60 62 104 108 130 179 260 225 300 210 210 210 210 210 210 210 84 87 145 151 182 251 364 315 420 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 125 43.3 45.0 52.0 104 130 143 150 52.0 54.0 62.4 125 156 171 210 72.7 75.7 87.3 175 218 240 — — — — — — — — — — — — — — 188 65.1 67.7 78.2 156 195 215 225 77.9 81.1 93.5 187 234 257 315 109 113 131 262 327 360 — — — — — — — — — — — — — — 250 86.6 90.1 104 208 260 286 300 104 108 125 249 312 343 420 145 151 175 349 436 480 — — — — — — — — — — — — — — =n ≤ 230V ≤ 240V ≤ 400V ≤ 415V ≤ 500V ≤ 690V ≤ 1000V 230V 240V 400V 415V 500V 690V 1000V ≤ 690V ≤ 690V [A] [A] [A] [A] [A] [A] [A] [kVA] [kVA] [kVA] [kVA] [kVA] [kVA] [kVA] [A] [A] 60 60 60 60 60 60 46 24 26 42 43 52 72 80 90 120 n=30 200V 208V 240V 480V 600V 660V [A] [kVA] [kVA] [kVA] [kVA] [kVA] [kVA] 60 20.8 21.6 24.9 49.9 62.4 68.6 n=20 200V 208V 240V 480V 600V 660V [A] [kVA] [kVA] [kVA] [kVA] [kVA] [kVA] 90 31.2 32.4 37.4 74.8 93.5 103 n=15 200V 208V 240V 480V 600V 660V [A] [kVA] [kVA] [kVA] [kVA] [kVA] [kVA] 120 41.6 43.2 49.9 99.8 125 137 70 70 85 85 105 70 70 85 85 105 70 70 85 85 105 70 70 85 85 105 70 70 85 85 105 70 70 85 85 105 70 70 85 85 105 28 28 34 34 42 29 29 35 35 44 48 48 59 59 73 50 50 61 61 75 61 61 74 74 91 84 84 102 102 125 121 121 147 147 182 105 105 128 128 158 140 140 170 170 210 60 Hz Peak Inrush/peak rated transformer current 70 70 85 85 105 24.2 24.2 29.4 29.4 36.4 25.2 25.2 30.6 30.6 37.8 29.1 29.1 35.3 35.3 43.6 58.2 58.2 70.7 70.7 87.3 72.7 72.7 88.3 88.3 109 80.0 80.0 97.2 97.2 120 60 Hz Peak Inrush/peak rated transformer current 105 105 128 128 158 36.4 36.4 44.3 44.3 54.7 37.8 37.8 46.1 46.1 56.9 43.6 43.6 53.2 53.2 65.7 87.3 87.3 106 106 131 109 109 133 133 164 120 120 146 146 131 60 Hz Peak Inrush/peak rated transformer current 140 140 170 170 210 48.5 48.5 58.9 58.9 72.7 50.4 50.4 61.2 61.2 75.7 58.2 58.2 70.7 70.7 87.3 116 116 141 141 175 145 145 177 177 218 160 160 194 194 240 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 111 Coil Type: Single capacitor 40°C Single capacitor 60 °C Group capacitors 40°C Group capacitors 60 °C 60 Hz Single Capacitor — 40 °C 60 Hz Group Capacitors — 40 °C Conventional Electronic — EI 230V 240V 400V 415V 500V 690V 1000V 230V 240V 400V 415V 500V 690V 1000V 230V 240V 400V 415V 500V 690V 1000V 230V 240V 400V 415V 500V 690V 1000V 200V 230V 460V 600V 200V 230V 460V 600V [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] 45 47 78 81 97 134 194 38 39 65 68 82 113 164 45 47 56 56 56 57 58 38 39 56 56 56 57 58 39 45 89 116 39 45 56 57 [A] [A] 144 122 225 189 225 189 225 189 225 189 315 270 [A] 120 140 140 170 170 210 Gas discharge lamps AC-5a, 40 °C open enclosed Individually compensated: Max. capacitance at expected Filament AC-5b 230/240V 112 100/104-D,100S-D 140 140 180 180 210 250 X — X — — — — X — X X X Switching of 3-phase Capacitors, AC-6b (50 Hz) 70 70 70 70 98 98 73 73 73 73 102 102 121 121 121 121 170 170 126 126 126 126 176 176 152 152 152 152 212 212 209 209 209 209 293 293 303 303 303 303 424 424 59 59 59 59 84 84 61 61 61 61 87 87 102 102 102 102 145 145 106 106 106 106 151 151 127 127 127 127 182 182 176 176 176 176 251 251 255 255 255 255 364 364 70 70 70 70 98 98 73 73 73 73 102 102 76 76 111 111 170 170 76 76 112 112 170 176 76 76 113 113 172 212 78 78 114 114 174 247 79 79 116 116 177 251 59 59 59 59 84 84 61 61 61 61 87 87 76 76 102 102 145 145 76 76 106 106 151 151 76 76 113 113 172 182 78 78 114 114 174 247 79 79 116 116 177 251 61 61 61 61 85 85 70 70 70 70 98 98 139 139 139 139 195 195 182 182 182 182 255 255 61 61 61 61 85 85 70 70 70 70 98 98 76 76 112 112 171 195 77 77 114 114 173 246 Switching of Lamps 115 X X 300 — X 420 — X 630 — X 860 — X 125 131 218 226 273 376 546 106 111 184 191 230 318 461 125 131 218 226 273 356 361 106 111 184 191 230 318 361 109 125 251 327 109 125 251 327 139 145 242 252 303 418 606 119 124 206 214 258 356 515 139 145 242 252 303 418 606 119 124 206 214 258 356 515 121 139 279 364 121 139 279 364 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 315 270 405 342 450 383 — — — — 250 300 420 — — Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100/104-D,100S-D 115 140 140 180 180 210 250 Conventional X X — X — — — Coil Type: Electronic — EI X — X — X X X Switching of Hermetically Sealed Cooling Compressor Motors - manual reset of overload release (50 Hz) 400V [A] 192 210 210 — — — — AC-8a 500V [A] 192 192 210 — — — — 690V [A] 192 192 210 — — — — Switching of DC Loads Non-inductive or slightly inductive loads or resistance furnaces DC-1, 60 °C [A] 135 210 210 210 210 300 300 24V 48/60V [A] 135 210 210 210 210 300 300 110V 1 pole [A] 135 210 210 210 210 300 300 220V [A] 3 3.3 3.3 3.3 3.3 4.9 4.9 440V [A] 0.6 0.75 0.75 0.75 0.75 1 1 [A] 135 210 210 210 210 300 300 24V 48/60V [A] 135 210 210 210 210 300 300 110V [A] 135 210 210 210 210 300 300 2 poles in series 220V [A] 135 210 210 210 210 300 300 440V [A] 3 3.3 3.3 3.3 3.3 4.9 4.9 [A] 135 210 210 210 210 300 300 24V 48/60V [A] 135 210 210 210 210 300 300 110V [A] 135 210 210 210 210 300 300 3 poles in series 220V [A] 135 210 210 210 210 300 300 440V [A] 11 11 11 11 11 14 14 Shunt-wound Motors, Starting, reverse current braking, reversing, stepping DC-3, 60°C 24V [A] 135 210 210 210 210 300 300 48/60V [A] 135 210 210 210 210 300 300 110V 3polesinseries [A] 135 210 210 210 210 300 300 220V [A] 135 210 210 210 210 300 300 440V [A] 3 3.5 3.5 3.5 3.5 4.1 4.1 Series-wound Motors, Starting, reverse current braking, reversing, stepping DC-5, 60 °C [A] 135 210 210 210 210 300 300 24V 48/60V [A] 135 210 210 210 210 300 300 110V 3 poles in series [A] 135 210 210 210 210 300 300 220V [A] 135 210 210 210 210 300 300 440V [A] 1.2 2.1 2.1 2.1 2.1 2.4 2.4 Short Time Withstand ICW, , 60 °C 10 s [A] 1040 1240 1360 1480 1480 2360 2520 Resistance and Power Dissipation Main current circuit resistance [m] 0.4 0.42 0.42 0.42 0.42 0.22 0.22 Power dissipation by all circuits at Ie AC-3/400V [W] 14.5 24.6 24.6 40.8 40.8 29.4 41.7 AC control [W] 24.5(20.5) 34.6 30.6 50.8 46.8 35.4 47.7 Total power dissipation At Ie AC-3/400V DC control [W] 22.5(20.5) 32.6 30.6 48.8 46.8 35.4 47.7 Lifespan Mechanical AC control [Million ops.] 10 10 10 10 10 10 10 Mechanical DC control [Million ops.] 10 10 10 10 10 10 10 Electrical AC-3 (400 V) [Million ops.] 1 1 1 1 1 1 1 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 300 — X 420 — X 630 — X 860 — X — — — — — — — — — — — — 380 380 380 4.9 1 380 380 380 380 4.9 380 380 380 380 14 425 425 425 5.2 1.2 425 425 425 425 5.2 425 425 425 425 15 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 380 380 380 380 4.1 425 425 425 425 5.8 — — — — — — — — — — 380 380 380 380 2.4 2840 425 425 425 425 3 4700 — — — — — 6300 — — — — — 7000 0.18 48.6 54.6 54.6 0.15 79.5 86.5 86.5 0.19 226.2 256.2 256.2 0.14 310.6 340.6 340.6 10 10 1 10 10 1 2 2 — 2 2 — 113 Coil Type: AC DC Conventional Electronic — EI Non-Rev. [kg (lbs)] Rev. [kg (lbs)] Non-Rev. [kg (lbs)] Rev. [kg (lbs)] 115 X X 3.3(7.28) [3.8 (8.38)](1) 3.14 (6.92) 3.3(7.28) [3.8 (8.38)](1) 3.22(7.1) 140 X — 140 — X 100/104-D,100S-D 180 210 — — X X 180 X — Weight 3.3 (7.28) 3.8 (8.38) 3.3 (7.28) — — — 3.3 (7.28) 3.8 (8.38) 3.3 (7.28) — — — 250 — X 3.8 (8.38) 7.5 (16.53) 7.5 (16.53) — — — 3.8 (8.38) 7.5 (16.53) 7.5 (16.53) — — — 300 — X 420 — X 630 — X 860 — X 7.5 (16.53) 7.5 (16.53) 28.6 (63) 28.6 (63) — — — — 7.5 (16.53) 7.5 (16.53) 28.6 (63) 28.6 (63) — — — — (1) Values in brackets refer to electronic coil (EI) version. Coil Type: Conventional Electronic — EI 115 X X 140 X X 180 X X 210 — X 250 — X 100/104-D,100S-D 300 420 — — X X (1) 630 — X 860 — X (1) (1) Conductor Cross Sections - Main Contacts Terminal type b max. c max. s max. [mm] [mm] [mm] 25 12.5 5 30 15 6 52 22 2x8 min. [mm] 8.3 10.5 13 [N•m] [lb-in] 43 380 100-DL420(1) (2x) 4…350 MCM 375 100-DTB420(2) 25…185 25…185 25…240 68 600 100-DL630 (2X) 2/0…500 MCM 400 — — — — 100-DL860 (4X) 2/0…500 MCM 400 — — — — Recommended torque Recommended torque With terminal lug kit Cross section per UL/CSA Recommended torque With Frame Terminal Block top opening bottom opening top opening [mm2] [mm2] [mm2] 22 195 100-DL180(1) 6…300 MCM 88…106 100-DTB180(1) 16…35 16…95 16…50 bottom opening [mm2] 16…120 25…240 — — b max. s top s bottom [mm] [mm] [mm] [N•m] [AWG] [AWG] [lb-in] 20 3…9 3…14 14 6…1/0 AWG 6 AWG…250 MCM 124 25 6…20 6…20 25 4 AWG…600 MCM 4 AWG…600 MCM 220 — — — — — — — — — — — — — — [AWG] [lb-in] Recommended torque Cross section per UL/CSA Recommended torque top bottom (1) Hexagonal socket screw (2) Pozidriv No. 2 / Blade No. 3 screw 114 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Short-Circuit Coordination Data See www.rockwellautomation.com/global/support/global-sccr.page for complete short-circuit current ratings. Coil Type: DIN Fuses- gG, gL Type"1"(690V) Type"2"(400V) Type"2"(690V) BS88Fuses Type"1"(415V) Type"2"(415V) 100/104-D,100S-D 115 140/180 140 180 210 250 300 Conventional X X — — — — — Electronic - EI X — X X X X X Short Circuit Coordination (Max. Fuse or Circuit Breaker Rating) Per IEC 60947-4-1 (contactor and fuses only) 50 kA Available Fault Current [A] 250 315 315 355 500 500 630 [A] 200 250 250 315 400 400 500 [A] 200 250 250 315 400 400 500 420 — X 630 — X 860 — X 630 500 500 TBD TBD TBD TBD TBD TBD [A] [A] 200 250 200 250 10 kA Available Fault Current 250 250 250 250 355 355 355 355 450 450 630 560 TBD TBD TBD TBD UL Listed Combination (600V) UL Class L Fuses [A] 250 350/450 18 kA Available Fault Current 350 450 500 — — — — — UL Listed Combination (600V) [A] — — — 700 700 1000 — — — — — — — — 2000 — — — — — — — — 2500 250 300 400 400 500 600 TBD TBD 200 250 300 — — — — — — — — 350 400 500 — — 200 200 250 — — — — — — — — 400 400 600 1200 — — — — — — — — 1200 200 200 250 400 400 600 TBD TBD 200 200 250 400 400 600 TBD TBD UL Class K5 and RK5 Fuses UL Class L Fuses UL Listed Combination (600V) [A] UL Class L Fuses UL Listed Combination (600V) UL Inverse-Time Circuit Breaker UL Listed Combination (600V) [A] [A] [A] [A] UL Inverse-Time Circuit Breaker UL Listed Combination (480V) UL Inverse-Time Circuit Breaker UL Listed Combination (480V) — 200 250/300 10 kA Available Fault Current 150 200/250 — — 125 200 30 kA Available Fault Current [A] UL Inverse-Time Circuit Breaker UL Listed Combination (600V) — 25 kA Available Fault Current UL Inverse-Time Circuit Breaker UL Listed Combination (600V) — 18 kA Available Fault Current UL Inverse-Time Circuit Breaker UL Listed Combination (600Y/347V) — 100 kA Available Fault Current [A] UL Inverse-Time Circuit Breaker UL Listed Combination (600V) — 42 kA Available Fault Current UL Class J and CSA HRCI-J Fuses UL verified combination to IEC60947-4-1 "Type2" — 30 kA Available Fault Current — — 42 kA Available Fault Current [A] [A] [A] — — 65 kA Available Fault Current 125 200 65kAAvailable Fault Current 125 200 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 115 Coil Data 100/104-D,100S-D 140/ 180 X — 115 Coil Type: 50 Hz, 60 Hz, 50/60 Hz DC control Conventional Electronic - EI X X 115 140 — — X X Operating Limits 180 210 250 300 420 630 860 — X — X — X — X — X — X — X pick-up dropout pick-up dropout [x Us] [x Us] [x Us] [x Us] 0.85…1.1 0.3…0.6 0.85…1.1 0.3…0.6 0.85…1.1 0.3…0.5 0.85…1.1 0.3…0.5 0.8…1.1 0.1…0.8 0.85…1.1 0.1…0.8 pick-up hold-in pick-up hold-in [VA/W] [VA/W] [W] [W] 650/310 50/10 540 8 closing delay [ms] 20…47 20…45 60…100 opening delay [ms] 6…12 25…110 70…145 Coil Consumption 50 Hz, 60 Hz, 50/60 Hz DC control 380/240(1) 13/6 265(1) 6 490/270(1) 18/7 340(1) 7 1915/1720 33/30 1980(1) 30 Operating Times AC With RC module closing delay [ms] 9…18 — — opening delay [ms] 27…47 25…50 60…100 closing delay [ms] 12…20 35…110 70…145 With integrated diode opening delay [ms] 12…20 With external diode opening delay [ms] — DC — — — — — (1) Electronic coil drives are designed to minimize power requirements, but this control may exhibit a higher inrush (540 W, < 10 ms) when energizing. This must be taken into account for the proper sizing of supply devices, all-or-nothing relays and cross-sections of coil supply lines. Please contact your local Rockwell Automation sales office or Allen-Bradley distributor for detailed information. Auxiliary Contacts, Auxiliary Contact Blocks, and Pneumatic Timers Side-mounted Conventional AC-12 Ith AC-15 at rated voltage of DC-12 L/R < 1 ms resistive loads at 116 at 40 °C at 60 °C 24V 42/48V 120V 230V 240V 400V 415V 500V 690V 24V DC 48V DC 110V DC 220V DC 440V DC Switching of AC Loads [A] 16 [A] 12 [A] 5.5 [A] 5.5 [A] 5.5 [A] 5.5 [A] 5 [A] 3 [A] 2.5 [A] 1.6 [A] 1 Switching of DC Loads [A] 16 [A] 9 [A] 3.5 [A] 0.55 [A] 0.2 Bifurcated 10 6 3 3 3 3 3 2 2 1.2 0.7 16 9 3.5 0.55 0.2 Electronically Compatible 0.1 at 250V (1…100 mA) at 3…125V — — — — — Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Side-mounted Conventional DC-14L/R <15 ms inductive loads with economy resistor in series at DC-13 switching electromagnets at 24V DC 48V DC 110V DC 220V DC 440V DC 24V DC 48V DC 110V DC 220V DC 440V DC Protective Separation per IEC 60947-1, Annex N Min. switching capacity according to IEC 60947-5-4 Rated voltage Continuous rating Switching capacity Rated voltage Switching capacity AC 40 °C AC DC DC [A] [A] [A] [A] [A] [A] [A] [A] [A] [A] Bifurcated Electronically Compatible — — — — — 9 5 2 0.4 0.1 5 2 0.7 0.25 0.12 [A] 9 5 2 0.4 0.16 5 2 0.7 0.25 0.12 Fuse gG 16 16 — [A] 16 16 — between load and auxiliary circuit 440V 17V/10 mA 5V/2 mA (1million ops.) Load Carrying Capacity per UL/CSA [V] max.600 [A] 10 General purpose [A] Heavy pilot duty (A600) [V] max.600 [A] Standard pilot duty (P600) Standard pilot duty (Q600) (1…100 mA) at 3…125V 3V/1 mA max.250 0.1 0.1 max.250 0.1 General Attribute Value Rated Isolation Voltage Ui IEC UL,CSA Rated Impulse Voltage Withstand Uimp [V] [V] [kV] 1000 600 12 AC 50/60 Hz DC Insulation Class of the Coil Rated coil frequency Ambient Temperature Storage Operation at rated voltage at 70 °C Climatic Withstand Max. Altitude of Installation Site Protection Class Single contactor cover Contactor with frame terminal block Auxiliary contact Protection against Accidental Contact Resistance to Shock Resistance to Vibration Mirror Contacts IEC60947-4 Annex F [V] [V] 230, 240, 400, 415, 500, 690, 1000 24, 48, 110, 220, 440 Class B per VDE 0660, Table 22 AC 50 Hz; 50/60Hz DC [°C] [°C] -40…+80 -25…+60 15% current reduction against 60 °C values IEC 60068-2-30 2000NN, per IEC60947-4 IP00 IEC 60529/DIN 40050 IP10 IEC 60529/DIN 40050 IP20 IEC 60529/DIN 40050 IP20 IEC60529/DIN 40050 Finger-and back-of-hand proof per VDE 0106, part 100 IEC 60068-2-27 IEC 60068-2-6 100-D…+2 x 100-DS1-11; 100S-D…+2 x 100S-DS1-11 Rated Voltage Ue [m] Rockwell Automation Publication 100-TD013F-EN-P - November 2017 117 Standards Compliance and Certifications 100-D IEC Contactors Standards Compliance Certifications IEC 60947-4-1 IEC 60947 Type “2” Coordination CSA 22.2. No. 14 UL 508 CE Marked CCC (115…180 A - conventional coil; 115…860 A - electronic coil) cULus Listed (File No. E 41850, Guide NLDX, NLDX7) 100S-D Safety Contactors Standards Compliance Certifications IEC 60947-4-1 IEC 60947-4 Annex F IEC 60947 Type “2” Coordination CSA C22.2 No. 14 UL 508 CE Marked cULus Listed (File No. E 41850, Guide NLDX, NLDX7) SUVA Certified CCC (115…180 A - conventional coil; 115…860 A - electronic coil) Life-Load Curves Figure 27 - AC-3, AC-1 Electrical life span AC-3 Switching of squirrel-cage motors while starting AC-1 Non- or slightly inductive loads, resistance furnaces, Ue = 415V AC 10.00 100-D115 100-D140 100-D180 100-D210 Contact life [Mio. of ops.] 100-D250 100-D300 100-D420 1.00 100-D115 AC-1 100-D140 AC-1 100-D180 AC-1 100-D210 AC-1 100-D250 AC-1 100-D300 AC-1 100-D420 AC-1 0.10 10 100 Rated operating current Ie AC-3 [A] (Dashed curves - - - - - AC-1 only, open) 118 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 1000 Figure 28 - AC-4 Electrical life span AC-4 Stepping of squirrel-cage motors, Ue = 415V AC 10.000 100-D115 100-D140 100-D180 100-D210 100-D250 100-D300 100-D420 Contact life [millions of ops.] 1.000 0.100 0.010 1 10 100 1000 Rated operating current, Ie AC-4 [A] Figure 29 - AC-3 90% and AC-4 10% Electrical life span Mixed operation of squirrel-cage motors, Ue = 415V AC AC-3 90% Switching of squirrel-cage motors while starting AC-4 10% Stepping of squirrel-cage motors 10.000 100-D115 100-D140 100-D180 100-D210 100-D250 100-D300 100-D420 Contact life [Mil. operations] 1.000 0.100 0.010 10 100 1000 Rated operating current Ie AC-3 / AC-4 [A] Rockwell Automation Publication 100-TD013F-EN-P - November 2017 119 Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes. Bulletin 100-D/104-D, 100S-D Approximate Dimensions Figure 30 - Bulletin 100-D/100S-D Contactors and Accessories e2 c1 e4 e1 b d1 e3 (1) øe ød d2 c a (1) Conventional DC coil contactors will have an additional auxiliary contact block that will add 13.5 mm to the “a” dimension on the right-hand side. Figure 31 - Mounting Position, 100-D/104-D Contactors 25° ° 90 90 ° 25° Figure 32 - Mounting Position, 100S-D Contactors 11 5° 90 ° 90 ° 25° ‡ Applies only to conventional single frequency, conventional DC and electronic coils. 120 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 AC and DC Contactors Cat. No. 100-D115E…100-D180E, 100-D115, 100-D140, 100-D180 100-D210E…100-D420E 100-D630E…100-D860E 100S-D115E…100S-D180E, 100S-D115, 100S-D140, 100S-D180 100S-D210E…100S-D420E 100S-D630E…100S-D860E a b c c1 d d1 d2 e e1 e2 e3 e4 120 170 156 110.5 5.2 145 100 8.5 20 39 160 10 155 255 205 310 180 265 110.5 110.5 6.5 10 180 230 130 225 10.4 M12 25 40 48 70 193 291 12.5 22 120 170 156 110.5 5.2 145 100 8.5 20 39 160 10 155 255 205 310 180 265 110.5 110.5 6.5 10 180 230 130 225 10.5 M12 25 40 48 70 193 291 12.5 22 Contactors with Accessories Contactor with Auxiliary contact block Mechanical Interlock Frame terminal block Label holder 100-DS1… 100-DS2… 100-DM… 100-DTB110 100-DTB180 100-DTB420 mm a a + 13.5 each a+a b + 7 each b + 7 each b + 8.5 each c…+ 5 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 121 Accessories Auxiliary Contacts Description Connection Diagram For Use With Standard Auxiliary Contact Cat. No. Bifurcated Cat. No. N.O. N.C. 1 1 100-D left or right inside mounting 100-DS1-11 100-DS1-B11H 1 1 100-D left or right outside mounting 100-DS2-11 100-DS2-B11H 1 1L 100-D left or right inside mounting 100-DS1-L11 — 2 0 100-D left or right inside mounting 100-DS1-20 100-DS1-B20H 2 0 100-D left or right outside mounting 100-DS2-20 100-DS2-B20H 1 1 100-D left or right inside mounting 100-DS1-B11 — 1 1 100-D left or right inside mounting 100-DS0-11 100-DS0-B11H 2 0 100-D left or right inside mounting 100-DS0-20 100-DS0-B20H 1 1L 100-D left or right inside mounting 100-DS0-L11 — 1 1 100-D left or right inside mounting 100-DS0-B11 — Auxiliary Contacts • Side-mounted • Without IEC sequence terminal designations • Standard contacts 17V/10 mA Bifurcated contacts for signals down to 5V/2 mA Auxiliary Contacts • Electronic-compatible auxiliary contacts • Ideal for use when switching low- power control circuits • With IEC sequence terminal designations • Contact ratings: AC-12, 250V, 0.1 A • AC-15, DC-13, 3...125V, 1...100 mA Auxiliary Contacts • Side-mounted • Without IEC sequence terminal designations • Standard contacts 17V/10 mA Bifurcated contacts for signals down to 5V/2 mA Auxiliary Contacts • Electronic-compatible auxiliary contacts • Ideal for use when switching low- power control circuits • Without IEC sequence terminal designations • Contact ratings: AC-12, 250V, 0.1 A • AC-15, DC-13, 3...125V, 1...100 mA 122 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Auxiliary contacts with sequence numbering. Figure 33 - Cat. Nos. 100-D115… D420 — Electronic and Conventional AC Coils, Electronic DC Coils Contact Configuration N.O. 8 Sequence Starts with: 7 Sequence Starts with: 6 Sequence Starts with: 5 Sequence Starts with: 4 Sequence Starts with: N.C. 0 For Use With 1 2 100-D…00 3 4 Auxiliary Contact Configurations Left Side Mounting Outside Cat. No. Inside Cat. No. 100-DS2-20 100-DS1-20 7/8 3/4 100-DS2-20 100-DS1-20 7/8 3/4 100-DS2-20 100-DS1-11 7/8 3/4 100-DS2-20 100-DS1-11 7/8 3/4 100-DS2-11 100-DS1-11 7/8 3/4 Right Side Mounting Inside Cat. No. Outside Cat. No. 100-DS1-20 100-DS2-20 1/2 5/6 100-DS1-11 100-DS2-20 1/2 5/6 100-DS1-11 100-DS2-20 1/2 5/6 100-DS1-11 100-DS2-11 1/2 5/6 100-DS1-11 100-DS2-11 1/2 5/6 Figure 34 - Cat. Nos. 100-D115… D420 — Electronic and Conventional AC Coils, Electronic DC Coils Supplied with Contactor Contact Configuration N.O. N.C. 8 0 Sequence Starts with: 7 1 Sequence Starts with: 6 2 Sequence Starts with: 5 3 Sequence Starts with: 4 4 Sequence Starts with: For Use With 100-D…11 Auxiliary Contact Configurations Left Side Mounting Right Side Mounting Outside Cat. No. Inside Cat. No. Inside Cat. No. Outside Cat. No. — — — — — — — — 100-DS2-20 100-DS1-20 100-DS1-11 100-DS2-20 7/8 3/4 1/2 5/6 100-DS2-20 100-DS1-11 100-DS1-11 100-DS2-20 7/8 3/4 1/2 5/6 100-DS2-20 100-DS1-11 100-DS1-11 100-DS2-11 7/8 3/4 1/2 5/6 100-DS2-11 100-DS1-11 100-DS1-11 100-DS2-11 7/8 3/4 1/2 5/6 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 123 Figure 35 - Cat. Nos. 100-D115… D180 — Conventional DC Coils Supplied with Contactor Auxiliary Contact Configurations Left Side Mounting Right Side Mounting Outside Cat. No. Inside Cat. No. Inside Cat. No. Outside Cat. No. — — — — — — — — — — — — — — — — 100-DS2-20 100-DS1-11 100-DS1-11(1) 100-DS2-20 7/8 3/4 1/2 5/6 100-DS2-20 100-DS1-11 100-DS1-11(1) 100-DS2-11 7/8 3/4 1/2 5/6 (1) 100-DS2-11 100-DS1-11 100-DS1-11 100-DS2-11 7/8 3/4 1/2 5/6 Contact Configuration N.O. N.C. 8 0 Sequence Starts with: 7 1 Sequence Starts with: 6 2 Sequence Starts with: 5 3 Sequence Starts with: 4 4 Sequence Starts with: Supplied with Contactor For Use With 100-D…22L (1) With conventional DC control, the pickup winding must be interconnected with the N.C. late-breaking auxiliary contacts. Marking Systems (For 100-D115...D860 contactors) Description Label Sheet • 105 self-adhesive paper labels each, 6 x 17 mm Marking Tag Sheet • 160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover Transparent Cover • To be used with marking tag sheets Marking Tag Adapters • To be used with marking tag: System V4/V5 Marking Tag Adapters • To be used with marking tag: System 1492 W Pkg. Qty.(1) Cat. No. 10 100-FMS 10 100-FMP 100 100-FMC 100 100-FMA1 100 100-FMA2 (1) Must be ordered in multiples of package quantities. 124 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Suppressor Modules Description Suppressor Module for Bul. 100-D Contactors • For limiting surge voltage when coil circuits are interrupted • Supplied as standard on all conventional DC coil contactors and all electronic coil contactors (as part of the supply module or delivered with separate suppressor module) Connection Diagram Suppressor Rating RC Module (AC control) For contactors with conventional coil 21...48V, 50 Hz; 24...55V, 60 Hz 95...110V, 50 Hz; 110...127V, 60 Hz 180...277V, 50 Hz; 208...277V, 60 Hz 380...550V, 50 Hz; 440...600V, 60 Hz Varistor Module for contactors with conventional coil 55V AC 56...136V AC 137...277V AC 278...600V AC Varistor Module for contactors with electronic coil 200...277V AC(1) 380...500V AC(2) For Use With Cat. No.(3) 100-DFSC48 100- D115...100- D180 100-DFSC110 100-DFSC240 100-DFSC550 100-DFSV55 100- D115...100- D420 100-DFSV136 100-DFSV277 100-DFSV575 100- D115...100- D420 100-DFSV550 100- D115...100- D300 100-DFSV500 (1) For overvoltage category IV (IEC 947 for 100-D...-El) e.g., lightning protection requirements. (2) For surge pulse > 1kV (3) Package Quantity = 1 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 125 Connecting Components Description 100-D115… 180 X For Use With 100-D210… 420 — 100-D630… 860 — 2 — X — 350 mm2 50 mm2 120 mm2 350 mm2 — X — — — — X — X — — X 50 mm2 X — — Terminal Blocks, 100-DTB… 100-D180-VTTB 80 mm2 — X — Terminal Blocks, 100-DTB… 100-D420-VYTB — — — X — — X — Cross- section 50 mm2 Reversing: Input Connection Wye-Delta: Main-Delta connection Reversing: Output Connection Wye-Delta: DeltaWye connection Delta-Wye connection if 100-D115…180 is used as a Wye contactor Wye-Delta: Neutral bridge 120 mm For 100-D115…D100-D180 Power Wiring Kits (for contactors using 100-DL lug kits) For 100-D210…100-D420 For 100-D630…100-D860 Terminal Blocks, 100-DTB… Lugs, 100-DL… Lugs, 100-DL… Lugs, 100-DL… — — — — X — Reversing Two-speed, or changeover Wye-Delta/Star-Delta Reversing Two-speed, or changeover Wye-Delta/Star-Delta Reversing Two-speed, or changeover (1) Package Quantity = 1 126 Terminal Connection Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Cat. No.(1) 100-D180-VLTB 100-D420-VLTB 100-D860-VL 100-D180-VT 100-D420-VT 100-D860-VT 100-D180-VYU 100-D420-VYU 100-D860-VYU 100-DPW180 100-D180-VLTB 100-DPY180 100-DPW420 100-D420-VLTB 100-DPY420 100-DPW860 100-D860-VL Connecting Components, Continued Description Terminal Lugs • Set of two • Protection class IP2X per IEC 60529 and DIN 40 050 For Use With 100-D115, 100-D140, 100-D180, 100-D115E…D180E, 193-EC_F, 193-EE_F Cat. No.(1) 100-DTB180 100-D210...100-D420, 193-EC_G, 193-EF2C, 193-EE_G 100-DTB420 100-D115, 100-D140, 100-D180, 193-EC_F, 193-EE_F 100-D210…100-D420, 193-EC_G, 193-EE_G 100-D630, 100-D860, 193-EC_H, 193-EE_H 100-DL180 100-DL420 100-DL630 100-D630, 100-D860, 193-EC_H, 193-EE_H 100-DL860 Connects to Cat. Nos. 100-D115...D180 100-DAT1 Control Circuit Terminal 2 x 25 mm2 Connects to Cat. Nos. 100-D210...D420 100-DAT2 Terminal Shields 100-D115, 100-D140, 100-D180, 100-D115E...100-D180-E Terminal Lugs (UL/CSA), Copper Frame Set of three • Set of two • Protection class IP10 per IEC 60529 and DIN 40 050 • For direct-on-line, reversing, two-speed, and wye-delta/star-delta 100-D210...100-D420 assemblies Terminal Covers 100-DTS420 100-D115...100-D180, 193-EC_F, 193-EE_F • Protection class IP10 per IEC 60529 and DIN 40 050 100-D120...100-D420, 193-EC_G, 193-EE_G • For direct-on-line, reversing, two-speed, and wye-delta/star-delta 100-D630...100-D860, 193-EC_H, 193-EE_H assemblies Terminal Covers Terminal Covers 100-D630...100-D860, 193-EC_H, 193-EE_H Terminal Covers 100-D115...100-D180 Mounting Plate • Galvanized steel plate for starter combinations 100-D120...100-D420, • For direct-on-line, reversing, two-speed, and wye-delta/star-delta, 193-EC_G, 193-EE_G and Dahlander assemblies 100-D630...100-D860, 193-EC_H, 193-EE_H Mounting Plate 100-DTC860 100-DTCR860 100-SDTCS860 • DOL Starter/relay cover • For two-speed or changeover switched 100-DTC180 100-DTC420 100-DTCE860 • Line-side panel relay and reversing cover • Reversing starter/ relay cover 100-DTS180 Direct-on-line Reversing, two-speed or changeover Y- or Dahlander Direct-on-line Reversing, two-speed or changeover Y- or Dahlander Direct-on-line Reversing, two-speed or changeover Y- or Dahlander For interlocking between 100-C60...C97 and 100-D115...D180 contactors 100-DMS180 100-DMU180 100-DMY180 100-DMS420 100-DMU420 100-DMY420 100-DMS860 100-DMU860 100-DMY860 100-DMU85 (1) Package Quantity = 2 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 127 Interlocks Description Interlock — Dual Electrical/Mechanical For Use With Cat. No.(1) 100-D115...100-D860 100-DMD02 100-D115...100-D860 100-DMD00 100-C60...100-C97 between 100D115...100-D180 100-DMC00 100-C60...100-C97 between 100D115...100-D180 100-DMC02 Circuit Diagram 22 NC 21 • No additional space requires • Two N.C. auxiliary contacts 21 NC 22 Interlock — Mechanical Only • No additional space required Interlock — Mechanical Only • Provides interlocking between Bul. 100-C and Bul. 100-D contactors Interlock — Dual Electrical/Mechanical 22 NC 21 • Provides interlocking between Bul. 100-C and Bul. 100-D contactors • Two N.C. auxiliary contacts 21 NC 22 (1) Package Quantity = 1 128 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Renewal Parts Description Coil Type Conventional Arc Chambers for Contactors • For 3-pole 100-D Contactors Electronic Conventional Main Contacts for Contactors • 3 complete sets for 3-pole 100-D Contactors Electronic Conventional Terminal Hardware • Set of 6 Electronic Rockwell Automation Publication 100-TD013F-EN-P - November 2017 For Use With 100-D115 100-D180 100-D115 100-D140 100-D180 100-D210 100-D250 100-D300 100-D420 100-D115 100-D140 100-D180 100-D115 100-D140 100-D180 100-D210 100-D250 100-D300 100-D420 100-D630 100-D860 100-D115…D180 100-D115E…D180 100-D210…D420 100-D630…D860 Cat. No. 100-DA-115 100-DA-180 100-DAE-115 100-DAE-140 100-DAE-180 100-DAE-210 100-DAE-250 100-DAE-300 100-DAE-420 100-DC-115 100-DC-140 100-DC-180 100-DCE-115 100-DCE-140 100-DCE-180 100-DCE-210 100-DCE-250 100-DCE-300 100-DCE-420 100-DCE-630 100-DCE-860 100-DHF180 100-DHF180 100-DHF420 100-DHF860 129 Replacement Coils Conventional AC Coils Conventional DC Coils 100100100100100100DC Standard AC Standard Control Voltages [V] AC Coil D95…D180 D210…D420 D630…D860 Control DC Coil Code D95…D180 D210…D420 D630…D860 Code Voltages [V] 50 Hz 60 Hz 50/60 Hz Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. 24V — — K TG407 — — 24V ZJ TG714 — — — 24V — J TG013 — — 48V ZY TG724 — — 48V — — Y TG414 — — 110V ZD TG733 — — 42V 48V — X TG482 — — 125V ZS TG737 — — — — 100V(1) KP TG861 — — 220V ZA TG761 — — 110V 120V — D TG473 — — — — 110V(1) KN TG856 — — — 208V — H TG049 — — — — 200V(1) KG TG862 — — — — 220V(1) KL TG857 — — 220…230V 240V — A TG441 — — 240V 277V — T TG480 — — — — 277V(1) KT TG060 — — — — 230V(1) KF TG851 — — (1) — — 240V KA TG858 — — 380…400V 440V — N TG071 — — 415V 480V — B TG475 — — 440V — — G TG478 — — 500V — — M TG479 — — 550V 600V — C TG476 — — Electronic AC Coils Electronic DC Coils 100100100100100100AC Standard Control Voltages [V] AC Coil D95…D180 D210…D420 D630…D860 DC Standard Control DC Coil Code D95…D180 D210…D420 D630…D860 Code Voltages [V] 50 Hz 60 Hz 50/60 Hz Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No. (2) — — 24V EJ TGE855 — — 24V EZJ TGE708 — — — — 42…64V EY TGE864 — — 48…72V EZY TGE779 — — — — 100V EP TGE861 THE861 TJE861 EZD TGE780 THE780 — 110…130V — — 110…130V ED TGE865 THE865 TJE865 ED — — TJE865 — — 200V EG TGE862 THE862 — EZA TGE781 THE781 — 200…255V — — 208…277V EA TGE866 THE866 — EA — — TJE879 — — 200…220V EG — — TJE878 — — 230…250V EA — — TJE879 — — 380…500V EN TGE867 THE867 — — — 380…415V EN — — TJE867 — — 440…480V EB — — TJE868 — — 500V EM — — TJE869 (1) Applies to 100-D95…-D115 contactors only. Not available with 100-D140…-D180 contactors. (2) Not available on 100/104?]D300 130 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100-G Contactors Product Selection—100-G Contactors • • • • • • 315...710 kW, 400V 350…900 Hp, 460/575V 3-Pole contactors 4th add-on neutral switching pole AC and DC control Horizontal and vertical interlocking Mechanical latching Meets IEC, CE, and cULus Standards and Certifications The Bulletin 100-G contactor product family provides reliable switching of motor loads up to 1200 A. A complete range of accessories including auxiliary contacts, mechanical latches, horizontal and vertical interlocks, and 4th add-on neutral switching poles provides maximum flexibility to meet a wide variety of application requirements. AC and DC Control Rated Operational Current Ie [A] Ratings for switching AC motors - AC-2, AC-3 kW (50 Hz)(1) 40 °C AC-1 (690V) 760 1000 1100 1200 1350 230V 160 220 280 315 375 400V 315 400 500 560 710 Auxiliary Contacts Hp (60 Hz) 500V 400 500 630 750 900 690V 500 630 710 850 1000 200V 150 200 250 — 450 230V 150 250 300 — 450 460V 350 500 600 — 900 Cat No. kW (50 Hz 575V 350 500 600 — 900 400 315 400 500 560 710 N.O. 2 2 2 2(2) 2 N.C. 2 2 2 2 2 100-G55022 100-G70022 100-G86022 (3)100-G100012 100-D120012 (1) Preferred values according to IEC 60072-1. (2) 1 N.O. contact used in control circuit (3) No UL/cUL Coil Voltage Codes The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No. Example: 120V, 60 Hz: Cat. No. 100-G55022 becomes Cat. No.100-G550KD22. AC Voltages [V], Conventional Coil 100…110 110…120 200…220 220…240 345…380 380…415 400…440 440…480 100-G550...100-G860 50/60 Hz — KD — KF — KN — KB DC KD — KF — KN — KB — AC Voltages [V], Conventional Coil 110…115 100-G1000...100-G1200 50/60 Hz KD DC — 110 — ZD(1) 220…230 KF — 220 — ZA(1) 240 KA — 380…400 KN — 440 KB — 480 KU — (1) Consult your local Rockwell Automation sales office or Allen-Bradley distributor. Rockwell Automation Publication 100-TD013F-EN-P - November 2017 131 Specifications Electrical Data 100-G550... 100-G700... 100-G860... 100-G1000 AC-1,Three-phase Switching-IEC Ambient temperature: 40 °C ≤690V [A] 760 1000 1100 1200 ≤230V [kW] 303 398 438 478 ≤240V [kW] 316 416 457 499 ≤400V [kW] 527 693 762 831 Ie ≤415V [kW] 546 719 791 863 ≤500V [kW] 658 866 953 1039 ≤690V [kW] 908 1195 1315 1434 Ambient temperature: 60 °C ≤690V [A] 605 800 870 960 ≤230V [kW] 241 319 347 382 ≤240V [kW] 251 333 362 399 ≤400V [kW] 419 554 603 665 Ie ≤415V [kW] 435 575 625 690 ≤500V [kW] 524 693 753 831 ≤690V [kW] 723 956 1040 1147 Continuous Current- UL/CSA General Purpose Rating 40 °C [A] 520 700 810 — Switching of 3-phase Motors-IEC AC-2,AC-3 230/240V [A] 550 700 860 1000 400/415V [A] 550 700 860 1000 500V [A] 550 700 860 1000 690V [A] 500 630 700 860 230V [kW] 179 228 280 326 240V [kW] 187 238 293 340 50Hz/60°C 400V [kW] 312 414 509 592 415V [kW] 324 430 528 628 500V [kW] 407 518 636 756 690V [kW] 510 657 730 897 AC-4 at 200 000 operations 230/240V [A] 140 180 210 260 400/415V [A] 140 180 210 260 230V [kW] 45 57 67 83 50Hz 240V [kW] 47 60 70 87 400V [kW] 78 101 118 146 415V [kW] 81 105 122 151 AC-4, Squirrel-cage motors with reversing and jogging at 20,000 (25,000),operations 230/240V [A] 360 430 520 (630) 400/415V(1) [A] 350 420 520 (630) 230V [kW] 116 139 170 (205) 240V [kW] 120 151 177 (214) 400V [kW] 198 238 295 (357) 415V [kW] 206 247 300 (359) (1) At rated Voltage 415V and rated current: Lifespan -25%. 132 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100-G1200 1350 538 561 935 970 1169 1613 1,085 432 451 752 780 940 1297 1215 1200 1200 1200 1000 391 408 710 737 888 1043 300 300 97 101 170 176 (700) (700) (228) (245) (414) (424) 100-G550... 100-G700... 100-G860... 100-G1000 Switching of 3-phase Motors-UL/CSA 200V [A] 414 552 692 — 230V [A] 360 602 722 — 460V [A] 414 590 708 — 575V [A] 336 472 576 — 60Hz/60°C 200V [Hp] 150 200 250 — 230V [Hp] 150 250 300 — 460V [Hp] 350 500 600 — 575V [Hp] 350 500 600 — Rated making capacity ≤415V [A] 5500 7000 8600 10000 AC-3 Ie ≤500V [A] 5500 7000 8600 10000 ≤690V [A] 5500 7000 8600 10000 Rated making capacity ≤240V [A] 4400 5600 6900 8000 ≤400V [A] 4400 5600 6900 8000 ≤415V [A] 4400 5600 6900 8000 AC-3 Ie ≤500V [A] 4400 5600 6900 8000 ≤690V [A] 4000 5100 5600 6900 Star-Delta Starting 230V [A] 953 1212 1490 1732 240V [A] 953 1212 1490 1732 400V [A] 953 1212 1490 1732 415V [A] 953 1212 1490 1732 500V [A] 953 1212 1490 1732 690V [A] 831 1091 1195 1490 50 Hz 230V [kW] 310 395 485 565 240V [kW] 324 412 507 589 400V [kW] 540 717 882 1025 415V [kW] 561 745 915 1088 500V [kW] 705 897 1102 1309 690V [kW] 883 1138 1247 1554 Wye-Delta Starting 230V [Hp] 250 400 500 650 460V [Hp] 600 800 1000 1300 60 Hz 575V [Hp] 600 800 1000 1500 Short-circuit Protection of Contactors without Overload Relay 500V [A] (630) 800 1000 1000 Fuse gG (aM) Type 1 coordination (per IEC 60947-4-1) 690V [A] (630) 800 1000 1000 Switching of Three-phase Capacitor Inductivity of dispatching between parallel switched capacitor: min. 6 pH 230V [kVar] 180 220 250 290 240V [kVar] 200 250 300 325 400V [kVar] 320 400 450 500 Single capacitors — 40 ° C 415V [kVar] 350 430 500 550 500V [kVar] 450 520 600 660 690V [kVar] 580 700 800 875 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 100-G1200 1185 1130 1062 864 450 450 900 900 12000 12000 12000 9600 9600 9600 9600 8000 2078 2078 2078 2078 2078 1732 677 707 1250 1278 1538 2078 750 1500 1500 1250 1000 330 360 575 630 750 1000 133 Single capacitors — 55 ° C 230V 240V 400V 415V 500V 690V Cat. No. [kVar] [kVar] [kVar] [kVar] [kVar] [kVar] 100-G550... 150 170 280 300 360 500 100-G700... 180 200 330 360 420 580 100-G860... 220 260 400 450 540 720 100-G1000 275 300 460 500 600 800 100-G550... 100-G700... 100-G860... Ratings for Switching Capacitor Banks 230V [kVar] 180 220 250 240V [kVar] 200 250 300 400V [kVar] 320 400 450 40 °C 415V [kVar] 350 430 500 500V [kVar] 450 520 600 690V [kVar] 580 700 800 230V [kVar] 150 180 220 240V [kVar] 170 200 260 400V [kVar] 280 330 400 55 °C 415V [kVar] 300 360 450 500V [kVar] 360 420 540 690V [kVar] 500 580 720 DC Switching Switching of non-or slightly inductive loads, resistance furnaces; DC-1 at 60°C 1 Pole 24/48V [A] 645 760 930 2 Poles in series 24/48V [A] 645 760 930 24/48V [A] 645 760 930 3 Poles in series 110V [A] 480 560 630 220V [A] 315 400 450 Shunt-Wound Motors Starting, plugging, reversing, plugging; DC-3 at 60 °C 3 Poles in series 24/48V [A] 605 800 870 Series-Wound Motors Starting, plugging, reversing, plugging; DC-5 at 60°C 3 Poles in series 24/48V [A] 605 800 870 Lighting Loads; Elec.Discharge.Lamps-AC-5a, Non-Compensated [A] 450 570 700 Compensated [A] 360 460 550 Incandescent Lamps-AC-5b, Electrical Endurance @100000 ops [A] 315 440 500 Switching Power Transformers AC-6a Inrush = n·Ie [A] 7440 9450 11700 Ie Rated transformer current [A] 248 315 390 400VAC [kVA] 172 218 270 n=30 500VAC [kVA] 215 273 338 690VAC [kVA] 269 339 376 n=20 [A] 371 472 580 n=15 [A] 435 630 774 134 100-G1200 325 350 550 600 720 950 100-G1000 100-G1200 290 325 500 550 660 875 275 300 460 500 600 800 330 360 575 430 750 1000 325 350 550 600 720 950 1020 1020 1020 800 500 1150 1150 1150 900 600 960 1085 960 1085 850 660 560 1000 800 630 13500 450 312 390 538 675 900 16200 540 374 468 645 810 1080 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Cat. No. 1s 4s 10s 15s 60s 240s 900s Minimum cooling time at zero current Main circuit resistance Total energy dissipation at Ie AC-3 AC Control DC Control Excess energy dissipation at Ie AC-3 100-G550... 100-G700... Rated Short-Time Withstand, ICW, 60 °C [A] 5500 7000 [A] 5500 7000 [A] 4400 5600 [A] 3800 5000 [A] 2300 2800 [A] 1300 1800 [A] 850 1150 [Min.] 60 60 Resistance and Energy Dissipation [m] 0.11 0.1 [W] 99 147 [W] 110 172 [W] 109 169 100-G860... 100-G1000 100-G1200 8000 8000 6900 6000 3400 2000 1350 60 10000 10000 8000 7400 4000 2300 1600 60 12000 12000 9600 8500 4800 2700 1900 60 0.08 177 202 199 0.06 180 250 240 0.05 216 286 276 Mechanical Data Mechanical Life Cat. No. AC Control DC Control [mm] [mm] 100-G550... 5 5 13.8 30.4 13.8 30.4 Terminals 6 x 40 (1) x 13 b max. c max. s max. [mm] [mm] [mm] Direct Connection 50 20 2x5 60 20 2x5 60 25 2x6 60 25 2x6 60 25 2x8 min. [mm] 12.5 13 15 2x13 2x13 75 55 60 44 60 44 50 3/8 62 550 (2) x 2.5 (2) x 2.5 50 3/8 56 500 (2) x 2.5 (2) x 2.5 60 3/8 56 500 (2) x 2.5 (2) x 2.5 AC Control Shipping Weights DC Control [Million operations] [Million operations] [kg] [lb] [kg] [lb] Terminal Dimensions Terminal screw hole size Terminations-Power Type 100-G700... 5 5 26.4 58.1 26.4 58.1 8 x 50 (1) x 13 50 60 37 44 Conductor/Wire Terminations [mm] 40 50 [in] 1/2 3/8 [N•m] 42 62 [lb•in] 375 550 [mm2] (2) x 2.5 (2) x 2.5 [mm2] (2) x 2.5 (2) x 2.5 100-G860... 5 5 28.4 62.5 28.4 62.5 8 x 50 (1) x 15 Hexagonal Bolt [N•m] [ft.-lb] Recommended Torque Busbar (Width) Hex screw Recommended Torque Auxiliary Contact Coils 100-G1000 1 1 50.3 110.8 50.3 110.8 100-G1200 1 1 53.4 117.6 53.4 117.6 10 x 50 (2) x 13 10 x 60 (2) x 13 Coil Data Cat. No. AC-50 Hz AC-60 Hz Pick-up Drop-out Pick-up Drop-out 100-G550... 100-G700... Operating Limits [x Us] [x Us] [x Us] [x Us] 100-G860... 100-G1000 100-G1200 0.85…1.1 0.2…0.5 0.2…0.75 0.1…0.6 0.85…1.1 0.2…0.5 0.2…0.75 0.1…0.6 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 135 DC Control AC-50 Hz AC-60 Hz DC Control AC DC Cat. No. Pick-up Drop-out [x Us] [x Us] 100-G550... Pick-up Hold-in Pick-up Hold-in Pick-up Hold-in [VA] [VA] [VA] [VA] [W] [W] Making delay Breaking delay Making delay Breaking delay [ms] [ms] [ms] [ms] 100-G700... 100-G860... 0.85…1.1 0.2…0.5 0.2…0.75 Pickup and Holding Power 800…950 1350…1600 9…11 21…25 800…950 1350…1600 9…11 21…25 700…850 1300…1550 8…10 18…22 Operating Times: Switching Delay 50…100 20…50(1)/150…200/500…1000(2) 50…100 20…50(1)/150…200/500…1000(2) 100-G1000 100-G1200 0.1…0.6 2400 70 2400 70 2100 60 50…100 25…50 50…100 25…50 (1) Accelerates (2) Delays Auxiliary Contacts Cat. No. AC-1 Ith AC-15 at rated voltage 100-G550... 100-G700... Switching of AC Loads Fuse gG 100-G1000 100-G1200 at 40 °C [A] 16 16 at 60 °C 120V [A] [A] 12 6 12 6 230V [A] 3 3 240V [A] 3 3 400V [A] 2 2 415V [A] 2 2 500V [A] 1.5 1.5 1 Switching of DC Loads 2V DC [A] 6 48V DC [A] 3 110V DC [A] 1 220V DC [A] 0.5 Back-up Fuse Short-circuit protection without contact welding per IEC60947-5 [A] 10 690V DC-13 control of electromagnets 100-G860... [A] 1 6 3 1 0.5 16 General Cat. No. IEC, AS, BS, SEV, VDE, 0660 UL,CSA Rated Impulse Voltage Withstand Uimp 1minuteperIEC947-4 AC, 50/60Hz DC Operating Frequency for AC Loads, 50/60 Hz Insulation Class of the Magnetic Coil Rated frequency of the Coil Ambient Temperature 136 [V] [V] [KV] [V] [Hz] 100-G550... 100-G700... Rated Isolation Voltage Ui 1,000 600 100-G860... 100-G1000 100-G1200 690 600 8 2,5 Rated Voltage-Main Control Ue 230, 240, 400, 415, 460, 500, 575, 690V 230, 240, 400, 415, 460, 500, 575, 690V 24, 48, 110, 220, 440V 180/hr. for 0.25 s start time-42/hr. for 1s start time Class B per VDE 0660, table 22 AC 50/60 Hz, DC Rockwell Automation Publication 100-TD013F-EN-P - November 2017 Cat. No. Storage Operation at rated current Climatic Withstand Altitude Type of Protection 100-G550... 100-G700... 100-G860... 100-G1000 100-G1200 -40 °C…+ 80 °C -25 °C…70 °C Damp alternating conditions cyclical, per DIN 50016 and 40046, part 38, IEC 60068 2000 m above sea level, per IEC60947-1 IP00 IEC 60529/DIN 40050 Standards Compliance and Certifications Standards Compliance Certifications EN/IEC 60947-4-1 IEC 60947 Type “1” Coordination CSA C22.2 No. 14 UL 508 CE Marked cULus Listed (File No. E 3125, Guide NLDX, NLDX7) Life-Load Curves 100-G550…100-G1200 Figure 36 - AC-3 Switching of Running Three-phase Motors, Ue = 380…460V AC; AC-1 Non or Slightly Inductive Loads, Resistance Furnaces Rockwell Automation Publication 100-TD013F-EN-P - November 2017 137 Figure 37 - AC-4 Jogging of Squirrel-cage Motors, Ue = 380…460V AC Contact Life (millions of operations) 10 100-G550 100-G700 100-G860 100-G1000 100-G1200 1 0.1 0.01 0.001 10 100 1000 10000 Rated Operational Current Ie AC-4 [A] Figure 38 - AC-3 90% Switching of Running Motors, Ue = 380…460V AC; AC-4 10% Jogging Contact Life (millions of operations) 10 100-G550 100-G700 100-G860 100-G1000 100-G1200 1 0.1 0.01 100 1000 Rated Operational Current Ie AC-3/AC-4 [A] 138 Rockwell Automation Publication 100-TD013F-EN-P - November 2017 10000 Permissible Switching Rate 100-G550…100-G1200 Figure 39 - Switching of Running Squirrel-cage Motors AC-3, Ue = 380…460V AC; Starting Time ts = 0.25 s, Relative Running Time 40% Permissible Switching Rate (operations/hour) 1000 100-G550 100-G700 100-G860 100-G1000, 100-G1200 100-G1200 (short time) 100 10 100 1000 10000 Rated Operational Current Ie [A] Figure 40 - Switching of Running Squirrel-cage Motors AC-3, Ue = 380…460V AC; Starting Time ts = 1 s, Relative Running Time 40% Permissible Switching Rate (operations/hour) 1000 100-G550 100-G700 100-G860 100-G1000,100-G1200 100-G1200 (short-time) 100 10 100 1000 10000 Rated Operational Current Ie [A] Rockwell Automation Publication 100-TD013F-EN-P - November 2017 139 Figure 41 - Switching of Starting Motors (AC-2, and AC4) Uz = 380…460V AC; Starting Time ted = 1 s, (
Source Exif Data:File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Author : Rockwell Automation Create Date : 2017:11:08 12:04:15Z Keywords : 100-TD013F-EN-P, 100-TD013E-EN-P, IEC, contactor, specifications, technical data, 100-C, 100-K, 100-D, 100-Q, 100S, 100-G, 100C, 100K, 100D, 100S-C, 100S-D, 100D, 100Q, 100G, safety, miniature, 100-E, 104-E, 100S-E, 100E, 104E Modify Date : 2017:11:27 13:09:52-06:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Creator Tool : FrameMaker 12.0.4 Metadata Date : 2017:11:27 13:09:52-06:00 Producer : Acrobat Distiller 17.0 (Windows) Format : application/pdf Title : IEC Contactor Specifications Creator : Rockwell Automation Subject : 100-TD013F-EN-P, 100-TD013E-EN-P, IEC, contactor, specifications, technical data, 100-C, 100-K, 100-D, 100-Q, 100S, 100-G, 100C, 100K, 100D, 100S-C, 100S-D, 100D, 100Q, 100G, safety, miniature, 100-E, 104-E, 100S-E, 100E, 104E Document ID : uuid:b586e644-048a-412c-9266-e9160dedc28c Instance ID : uuid:eb13f57f-61f4-4672-a505-d76e5e2a7ef9 Page Layout : SinglePage Page Mode : UseOutlines Page Count : 146EXIF Metadata provided by EXIF.tools