演示文稿 167WCP F18 Installation Guide ZKACCESS
User Manual:
Open the PDF directly: View PDF
.
Page Count: 30
| Download | |
| Open PDF In Browser | View PDF |
www.zkaccess.com Safety Precautions How to place a finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate Power Connection Ethernet Connection PC RS485 Connection FR1200 RS485 Connection Lock Relay Connection Weigand Input Connection Weigand Output Connection Installation Reference Specifications Electrical Specifications Troubleshooting Specifications 1 02 04 07 09 11 12 13 14 15 17 18 19 21 22 23 26 27 28 1Safety Precautions The following precautions are to keep user’s safe and prevent any damage. Please read carefully before installation. Do not install the device in an area subject to direct sunlight, humidity or dust Be careful not to let liquid like water, drinks or chemicals leak inside the device. Do not place a magnet near the product. Magnetic field from magnets, CRT, TV, monitor or speaker may damage the device. Clean the device often to remove dust on it 2 Do not place the device next to heating equipment. Do not let children touch the device without supervision. 1Safety Precautions The following precautions are to keep user’s safe and prevent any damage. Please read carefully before installation. Do not drop the device. Do not damage the device Do not disassemble, repair or alter the device. In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel. 3 Do not use the device for any other purpose than specified. Contact your nearest dealer in case of a trouble or problem. 1How to Place a Finger ZkTeco’s fingerprint readers will give optimal results for fingerprint matching if the following recommendations and suggestions are followed. Select a finger to enroll It is recommended to use an index finger or a middle finger. Thumb, ring or little finger are relatively difficult to place in the correct position How to place a finger on a sensor Place a finger such that it completely covers the sensor area with maximum contact. Place core of the fingerprint at the center of the sensor. The core of a fingerprint is a center where the spiral of ridges is dense. Usually core of fingerprint is the opposite side of the lower part of a nail. Place a finger such that the bottom end of a nail is located at the center of a sensor . If a finger is placed as shown in the right, only a small area of a finger is captured. So it is recommended to place a finger as shown on the left. 4 1How to Place a Finger Tips for different fingerprint conditions ZKTeco’s fingerprint products are designed to verify fingerprints with highest security irrespective of the conditions of the skin of the finger. However, in case a fingerprint is not read on the sensor, please refer to the followings tips. • If a finger is stained with sweat or water, scan after wiping moisture off. • If a finger is covered with dust or impurities, scan after wiping them off. • If a finger is way too dry, please blow some warm air from your mouth on the finger tip. Tips for fingerprint enrollment In fingerprint recognition, enrollment process is very important. When enrolling a fingerprint, please try to place the finger correctly with utmost care. In case of low acceptance ratio, the following actions are recommended. • Delete the enrolled fingerprint and re-enroll the finger. • Enroll the same fingerprint again. • Try another finger if a finger is not easy to enroll due to scar or cuts. In case of an enrolled fingerprint cannot be used due to injury or if the hand is full, it is recommended to enroll more than two fingers per user. 5 1How Does F18 work Register finger Open door Identification Feature extraction Verified successfully Thank you ! Verify feature Door closed Verification failed Please try again ! Fingerprint database Create Event logs Stored 6 Product Contents Basic Contents Screw Driver – 2 pcs. Star-shape Screw for Mounting Plate -2 pcs F18 2 pin, 4 pin, 7 pin, 8 pin, 10 pin cables – each 1 pcs Metallic Back Plate 7 Wall Mounting Screws – 4 pcs. Mini-USB Cable -1 pcs Mounting Paper Wall Plugs– 4 pcs Product Contents Optional accessories Weigand Card Reader RS485 Convertor FR1200 Slave Fingerprint Reader Prox Card 12VDC, 3A Power Adaptor USB Memory 8 K1-1 Exit Button Alarm Product PIN Diagram Side Front 2.4 inch TFT LCD USB Memory slot Reset Switch Keypad & RF Card Area Door Bell & LED Indicator Speaker Slot ZK Optical Sensor 9 Product PIN Diagram Bottom Back 4 pin Cable connectors –Ethernet (TCP/IP) 7 pin Cable connectors 8 pin Cable connectors Beep, LED Weigand In Power Out Weigand Out RS232 RS485 2 pin Cable connectors -Power In 10 pin Cable connectors Tamper alarm button Bell Door Sensor Button Lock Alarm (At the back of the mounting plate ) Star-shaped screw hole for fixing reader to the back plate 10 Product Dimension 80mm (3.15in.) 80mm (3.15in.) 183mm (7.20in.) 183mm (7.20in.) Front Side 11 42mm (1.65in.) 183mm (7.20in.) Back Plate Cables and Connectors Digital input and Relay output 1 Alarm Lock Button Door Sensor Door Bell 10 Weigand output and RS485 1 Weigand Output RS232 RS485 8 Weigand input and Power out 1 Weigand Input LED Power Out 7 Ethernet 1 TCP/IP 4 Power In Power In 1 2 12 Beep Installation of Wall-mount Fix back plate to the wall using wall mounting screws Mount F18 terminal on the Back plate Secure F18 and back plate using a star shape screw. Star-shaped screw Wall mounting screws Star-shaped screw driver 13 Power Connection Without UPS 12V DC (Red) 12V DC GND (Black) GND With UPS (Optional) 12V DC (Red) 12V DC GND (Black) GND Recommended power supply 12V ± 10%, at least 500mA. Comply with standard IEC/EN 60950-1. To share the power with other devices, use a power supply with higher current ratings 14 Ethernet Connection Ethernet Connection TCP/IP TCP/IP 15 Ethernet Connection Direct Connection to PC TCP/IP 16 PC RS485 Connection PC RS485 Connection RS232 RS485B RS485A GND Important Notes Do’s and Dont’s for RS485 connection 1. RS485 communication wires should be a shielded or twisted pair cable. RS485 communication wires should be connected in a bus cascade instead of a star form, to achieve a better shielding effect by reducing signal reflection during communications. 3. Adjust the communication speed as needed , The signal quality vary depending on wiring conditions, and it maybe necessary to lower the baudrates. 4. The GND Signal may be omitted if and only if the GND potential difference is less than ±5V 17 FR1200 RS485 Connection Power Out 12V DC (Red) 12V DC (Red) GND (Black) GND (Black) GND (Black) GND (Black) 485A (blue) 485+ (Purple) 485B (Yellow) 485- (Yellow) Important Notes 1 2 3 Menu -> User Management -> Access Setting -> Anti-Passback setting -> 485Reader Fun(Y) 18 1.Steps to activate the master and salve functionality between F18 and FR1200 is shown in the diagram on the left. 2. There are six DIP switches on the back of FR1200 , Switches 1-4 is for RS485 address , switch 5 is reserved , switch 6 is for reducing noise on long RS485 cable. 3. If FR1200 is powered from F18 terminal ,the length of wire should be less than 100 meters or 330 ft. 4. If the cable length is more than 200 meters or 600 ft. , the number 6 switch should be ON as below Distance More than 200 meters Lock Relay Connection For Normally Open -Lock FR107 1 Sensor SEN GND Sensor GND NO1 COM NC1 12V DC 12V DC GND 10 Lock F18 19 Lock Relay Connection For Normally Close-Lock 1 Sensor SEN GND Sensor NO1 COM NC1 12V DC GND 12V DC GND 10 FR107 Lock F18 20 Weigand Input Connection 1 DC+(6-14V) GND Weigabd1 Weigand0 +12V GND INWD1 INWD0 RLED GLED Beep Green LED Beeper 7 Weigand Card Reader 21 F18 Weigand Output Connection WD1 WD0 GND Access controller 22 F18 Installation Reference Standalone LOCK Door Sensor Exit button Door 23 Alarm Installation Reference Third Party Controller Weigand Output Connection Weigand Output Weigand Output Weigand Output LOCK Outside Door Door Sensor Weigand Output LOCK Inside Door 24 Inside Door Door Sensor Outside Door Installation Reference Third Party Controller RS485 Connection EXT RS485 EXT RS485 EXT RS485 EXT RS485 LOCK Outside Door Door Sensor LOCK Inside Door 25 Inside Door Door Sensor Outside Door Specification Item Specification Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZEM720 CPU ZK 6001, 400Mhz Memory 64M Flash, 32MSDRAM Fingerprint Sensor ZK optical sensor Display 2.8” TFT LCD color screen LED Indicator Red, Green Communication Ethernet(10/100M), RS485, USB-HOST, Weigand signal Wiegand Input and Wiegand Output Identification speed ≤2 sec FAR ≤0.0001% FRR ≤1% Operating Temperature 0-45℃ Operating Humidity 20%-80% Language English, Spanish, Portuguese, French… Power Supply 12V DC, 3A Access control interfaces Electric lock, alarm, exit button, wired door bell Dimension 80*183*42mm (L*W*D) 26 Electrical Specification Min. Typ. Max. Notes Working power supply Voltage(V) 9.6 12 14.4 Current(A) Use regulated DC power adaptor only 2 Electronic lock relay output Switching voltage(V) 36V Switching Current(A) 2 Use regulated DC power adaptor only Switch Aux. input VIH (V) TBD VIL (V) TBD Pull-up resistance (Ω) 4.7k The input ports are pulled up with 4.7k resistors WEIGAND Input Voltage(V) 10.8 12 Current(mA) 13.5 500 TTL/WEIGAND Output VoH (V) 5 VoL (V) 0.8 Pull-up resistance (Ω) 4.7K The outputs ports are open drain type, pulled up with 4.7k resistors internally ZK Electronic lock Voltage(V) Current(mA) 10.8 12 13.2 500 27 Troubleshooting Fingerprint can not be read or it takes too long. Check whether a finger or fingerprint sensor is stained with sweat, water, or dust Retry after wiping off finger and fingerprint sensor with dry paper tissue or a mildly wet cloth. If a fingerprint is way too dry, blow on the finger and retry. Fingerprint is verified but authorization keeps failing. Check whether the user is restricted by door zone or time zone. Check with administrator whether the enrolled fingerprint has been deleted from the device for some reason. Authorized but door does not open. Check whether the lock duration is set to appropriate minutes which opens the lock. Check whether anti-passback mode is in use. In anti-passback mode, only the person who has entered through that door can exit. Why device display “system broken“ and the alarm is ringing. Check whether the device and back plate are securely connected to each other. If not, a tamper switch is activated which triggers the alarm and keeps it ringing. How to set F18 used as fingerprint reader on Inbio access controller. Please contact our technical support department 28 Copyright 2013 ZKTeco Inc. All right reserved. ZKTeco May, at any time and without notice , Make changes or improvements to the product and services offered and/or cease producing or commercializing them. ZK USA office: 201 Circle Drive North, Suite 116 Piscataway, NJ 08854, USA Tel: +1 732-412-6007 Fax +1 732-412-6008 sales@zkaccess.com zkaccess.com Functions and specifications of the product are subject to change without notice due to quality enhancement or function update. For any inquiry for the product, please contact ZKACCESS.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 30 Language : en-US Tagged PDF : Yes Title : PowerPoint 演示文稿 Author : eli Create Date : 2013:08:30 15:49:04-04:00 Modify Date : 2013:08:30 15:49:04-04:00 Producer : Microsoft® PowerPoint® 2013 Creator : Microsoft® PowerPoint® 2013EXIF Metadata provided by EXIF.tools