演示文稿 167WCP F18 Installation Guide ZKACCESS

User Manual:

Open the PDF directly: View PDF PDF.
Page Count: 30

Download演示文稿 167WCP F18-Installation-guide-ZKACCESS
Open PDF In BrowserView PDF
www.zkaccess.com

Safety Precautions
How to place a finger

Product Contents
Product PIN Diagram
Product Dimensions
Cables and Connectors

Installation of Back Plate
Power Connection
Ethernet Connection
PC RS485 Connection

FR1200 RS485 Connection
Lock Relay Connection
Weigand Input Connection
Weigand Output Connection

Installation Reference
Specifications
Electrical Specifications
Troubleshooting

Specifications
1

02
04
07
09
11
12
13
14
15
17
18

19
21
22
23
26
27
28

1Safety Precautions
The following precautions are to keep user’s safe and prevent any damage. Please read carefully before installation.

Do not install the device in an area subject to
direct sunlight, humidity or dust

Be careful not to let liquid like
water, drinks or chemicals leak
inside the device.

Do not place a magnet near the product. Magnetic
field from magnets, CRT, TV, monitor or speaker
may damage the device.

Clean the device often to remove
dust on it

2

Do not place the device next to
heating equipment.

Do not let children touch the
device without supervision.

1Safety Precautions
The following precautions are to keep user’s safe and prevent any damage. Please read carefully before installation.

Do not drop the device.

Do not damage the device

Do not disassemble, repair or
alter the device.

In cleaning, do not splash water
on the device but wipe it out with
smooth cloth or towel.

3

Do not use the device for any
other purpose than specified.

Contact your nearest dealer in
case of a trouble or problem.

1How to Place a Finger
ZkTeco’s fingerprint readers will give optimal results for fingerprint matching if the following recommendations and
suggestions are followed.

Select a finger to enroll
 It is recommended to use an index finger or a middle finger.
 Thumb, ring or little finger are relatively difficult to place in the correct position

How to place a finger on a sensor
 Place a finger such that it completely covers the sensor area with maximum contact.
 Place core of the fingerprint at the center of the sensor. The core of a fingerprint is a center where the spiral of ridges is
dense.





Usually core of fingerprint is the opposite side of the lower part of a nail.
Place a finger such that the bottom end of a nail is located at the center of a sensor .

If a finger is placed as shown in the right, only a small area of a finger is captured. So it is recommended to place a finger as
shown on the left.

4

1How to Place a Finger
 Tips for different fingerprint conditions
 ZKTeco’s fingerprint products are designed to verify fingerprints with highest security irrespective of the
conditions of the skin of the finger. However, in case a fingerprint is not read on the sensor, please refer to the
followings tips.
• If a finger is stained with sweat or water, scan after wiping moisture off.
• If a finger is covered with dust or impurities, scan after wiping them off.
• If a finger is way too dry, please blow some warm air from your mouth on the finger tip.




Tips for fingerprint enrollment
In fingerprint recognition, enrollment process is very important. When enrolling a fingerprint, please try to place the
finger correctly with utmost care.
 In case of low acceptance ratio, the following actions are recommended.
• Delete the enrolled fingerprint and re-enroll the finger.
• Enroll the same fingerprint again.
• Try another finger if a finger is not easy to enroll due to scar or cuts.



In case of an enrolled fingerprint cannot be used due to injury or if the hand is full, it is recommended to enroll more
than two fingers per user.

5

1How Does F18 work

Register finger

Open door

Identification

Feature extraction

Verified
successfully

Thank you !

Verify feature

Door closed

Verification
failed

Please try again !

Fingerprint database

Create

Event logs
Stored

6

Product Contents
 Basic Contents

Screw Driver – 2 pcs.

Star-shape Screw for
Mounting Plate -2 pcs

F18

2 pin, 4 pin, 7 pin, 8 pin,
10 pin cables – each 1 pcs

Metallic Back Plate
7

Wall Mounting Screws – 4 pcs.

Mini-USB Cable -1 pcs

Mounting Paper

Wall Plugs– 4 pcs

Product Contents
 Optional accessories

Weigand Card Reader

RS485 Convertor

FR1200 Slave Fingerprint Reader

Prox Card

12VDC, 3A Power
Adaptor

USB Memory

8

K1-1 Exit Button

Alarm

Product PIN Diagram
 Side

 Front

2.4 inch TFT LCD
USB Memory slot

Reset Switch

Keypad & RF Card Area

Door Bell & LED Indicator

Speaker Slot

ZK Optical Sensor

9

Product PIN Diagram
 Bottom

 Back
4 pin Cable connectors –Ethernet (TCP/IP)
7 pin Cable connectors

8 pin Cable connectors

Beep, LED
Weigand In
Power Out
Weigand Out
RS232
RS485

2 pin Cable connectors -Power In

10 pin Cable connectors

Tamper alarm button

Bell
Door Sensor
Button
Lock
Alarm

(At the back of the mounting plate )

Star-shaped screw hole for fixing reader to the back plate

10

Product Dimension
80mm
(3.15in.)

80mm
(3.15in.)

183mm
(7.20in.)
183mm
(7.20in.)

Front

Side
11

42mm
(1.65in.)

183mm
(7.20in.)

Back Plate

Cables and Connectors
Digital input and Relay output
1
Alarm

Lock

Button

Door
Sensor

Door Bell

10

Weigand output and RS485
1

Weigand
Output

RS232

RS485

8
Weigand input and Power out
1
Weigand
Input

LED

Power Out

7
Ethernet

1

TCP/IP

4

Power In
Power In

1
2

12

Beep

Installation of Wall-mount
 Fix back plate to the wall
using wall mounting screws

 Mount F18 terminal on the
Back plate

 Secure F18 and back plate
using a star shape screw.

Star-shaped screw

Wall mounting screws

Star-shaped screw
driver

13

Power Connection
 Without UPS

12V DC (Red)

12V DC

GND (Black)

GND

 With UPS

(Optional)

12V DC (Red)

12V DC

GND (Black)

GND






Recommended power supply
12V ± 10%, at least 500mA.
Comply with standard IEC/EN 60950-1.
To share the power with other devices, use a power supply with higher current ratings

14

Ethernet Connection
 Ethernet Connection

TCP/IP

TCP/IP

15

Ethernet Connection
 Direct Connection to PC

TCP/IP

16

PC RS485 Connection
 PC RS485 Connection

RS232

RS485B
RS485A
GND

 Important Notes

 Do’s and Dont’s for RS485 connection

1. RS485 communication wires should be a shielded
or twisted pair cable. RS485 communication wires
should be connected in a bus cascade instead of a star
form, to achieve a better shielding effect by reducing
signal reflection during communications.
3. Adjust the communication speed as needed , The
signal quality vary depending on wiring conditions,
and it maybe necessary to lower the baudrates.
4. The GND Signal may be omitted if and only if the
GND potential difference is less than ±5V

17

FR1200 RS485 Connection
Power Out

12V DC (Red)

12V DC (Red)

GND (Black)

GND (Black)

GND (Black)

GND (Black)

485A (blue)

485+ (Purple)

485B (Yellow)

485- (Yellow)

 Important Notes

1

2

3
Menu -> User Management -> Access Setting
-> Anti-Passback setting -> 485Reader Fun(Y)

18

1.Steps to activate the master and salve functionality between
F18 and FR1200 is shown in the diagram on the left.
2. There are six DIP switches on the back of FR1200 , Switches
1-4 is for RS485 address , switch 5 is reserved , switch 6 is for
reducing noise on long RS485 cable.
3. If FR1200 is powered from F18 terminal ,the length of wire
should be less than 100 meters or 330 ft.
4. If the cable length is more than 200 meters or 600 ft. , the
number 6 switch should be ON as below
Distance
More than 200 meters

Lock Relay Connection
For Normally Open -Lock

FR107

1
Sensor

SEN
GND

Sensor
GND

NO1
COM
NC1

12V DC
12V DC

GND

10

Lock

F18

19

Lock Relay Connection
For Normally Close-Lock

1
Sensor

SEN
GND

Sensor

NO1
COM
NC1

12V DC
GND
12V DC

GND

10
FR107

Lock

F18

20

Weigand Input Connection

1
DC+(6-14V)
GND
Weigabd1
Weigand0

+12V
GND
INWD1
INWD0
RLED
GLED
Beep

Green LED
Beeper
7

Weigand Card Reader

21

F18

Weigand Output Connection

WD1
WD0
GND

Access controller

22

F18

Installation Reference
Standalone

LOCK

Door Sensor Exit button

Door

23

Alarm

Installation Reference
Third Party Controller

Weigand Output Connection

Weigand
Output

Weigand
Output

Weigand
Output

LOCK

Outside Door

Door Sensor

Weigand
Output

LOCK

Inside Door

24

Inside Door

Door Sensor

Outside Door

Installation Reference
Third Party Controller

RS485 Connection

EXT RS485

EXT RS485
EXT RS485

EXT RS485

LOCK

Outside Door

Door Sensor

LOCK

Inside Door

25

Inside Door

Door Sensor

Outside Door

Specification
Item

Specification

Fingerprint capacity

3,000

Transaction capacity

100,000

Hardware Platform

ZEM720

CPU

ZK 6001, 400Mhz

Memory

64M Flash, 32MSDRAM

Fingerprint Sensor

ZK optical sensor

Display

2.8” TFT LCD color screen

LED Indicator

Red, Green

Communication

Ethernet(10/100M), RS485, USB-HOST,

Weigand signal

Wiegand Input and Wiegand Output

Identification speed

≤2 sec

FAR

≤0.0001%

FRR

≤1%

Operating Temperature

0-45℃

Operating Humidity

20%-80%

Language

English, Spanish, Portuguese, French…

Power Supply

12V DC, 3A

Access control interfaces

Electric lock, alarm, exit button, wired door bell

Dimension

80*183*42mm (L*W*D)

26

Electrical Specification
Min.

Typ.

Max.

Notes

Working power supply
Voltage(V)

9.6

12

14.4

Current(A)

Use regulated DC power adaptor only

2

Electronic lock relay output

Switching voltage(V)

36V

Switching Current(A)

2

Use regulated DC power adaptor only

Switch Aux. input
VIH (V)

TBD

VIL (V)

TBD

Pull-up resistance (Ω)

4.7k

The input ports are pulled up with 4.7k resistors

WEIGAND Input
Voltage(V)

10.8

12

Current(mA)

13.5
500

TTL/WEIGAND Output
VoH (V)

5

VoL (V)

0.8

Pull-up resistance (Ω)

4.7K

The outputs ports are open drain type, pulled up with 4.7k
resistors internally

ZK Electronic lock
Voltage(V)
Current(mA)

10.8

12

13.2
500

27

Troubleshooting
 Fingerprint can not be read or it takes too long.
 Check whether a finger or fingerprint sensor is stained with sweat, water, or dust
 Retry after wiping off finger and fingerprint sensor with dry paper tissue or a mildly wet cloth.
 If a fingerprint is way too dry, blow on the finger and retry.

 Fingerprint is verified but authorization keeps failing.
 Check whether the user is restricted by door zone or time zone.
 Check with administrator whether the enrolled fingerprint has been deleted from the
device for some reason.

 Authorized but door does not open.
 Check whether the lock duration is set to appropriate minutes which opens the lock.
 Check whether anti-passback mode is in use. In anti-passback mode, only the person who
has entered through that door can exit.

 Why device display “system broken“ and the alarm is ringing.
 Check whether the device and back plate are securely connected to each other. If not, a
tamper switch is activated which triggers the alarm and keeps it ringing.

 How to set F18 used as fingerprint reader on Inbio access controller.
 Please contact our technical support department

28

Copyright 2013 ZKTeco Inc. All right reserved.
ZKTeco May, at any time and without notice , Make changes or
improvements to the product and services offered and/or cease
producing or commercializing them.

ZK USA office:
201 Circle Drive North, Suite 116
Piscataway, NJ 08854, USA
Tel: +1 732-412-6007
Fax +1 732-412-6008
sales@zkaccess.com
zkaccess.com

Functions and specifications of the product are subject to change without notice due to quality enhancement or function update.
For any inquiry for the product, please contact ZKACCESS.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 30
Language                        : en-US
Tagged PDF                      : Yes
Title                           : PowerPoint 演示文稿
Author                          : eli
Create Date                     : 2013:08:30 15:49:04-04:00
Modify Date                     : 2013:08:30 15:49:04-04:00
Producer                        : Microsoft® PowerPoint® 2013
Creator                         : Microsoft® PowerPoint® 2013
EXIF Metadata provided by EXIF.tools