Sampling With ULTRA Passive (Diffusive) Samplers Sample Setup Guide Publication 1744 PDF
User Manual: 1744
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Sample Setup Guide Sampling with ULTRA Passive (Diffusive) Samplers Passive sampling is the collection of airborne gases and vapors at a rate controlled by a physical process such as diffusion, without the use of an air sampling pump. Passive (diffusive) samplers rely on the movement of contaminant molecules across a concentration gradient (i.e., molecules diffuse from an area of high concentration in air to an area of low concentration onto the sampler). This rate of diffusion can be calculated mathematically and determined experimentally for individual chemicals. SKC provides diffusion or sampling rates for many organic vapors that can be sampled with SKC ULTRA Passive Samplers. This Sample Setup Guide demonstrates the basic operation of SKC ULTRA Passive Samplers and defines the critical sampling information that should be sent to a laboratory for analysis. Introduction SKC offers ULTRA Passive Samplers with a choice of sorbents. Choose the sampler with the sorbent best suited for the chemical(s) of interest. Refer to the SKC Passive Sampling Guide on the SKC website, www.skcinc.com, for more information. The sorbents and analysis for ULTRA Passive Samplers are the same as those specified in the active EPA Method TO-17. ULTRA samplers provide for low parts per billion (ppb) to parts per trillion (ppt) detection of organic vapors in ambient and indoor air.1 Consult the SKC Passive Sampling Guide for sampling rates and minimum and maximum sampling times. ULTRA Passive Samplers are offered in two configurations. Select the configuration that best fits your application. Prefilled ULTRA Passive Samplers The ULTRA sampler housing is prefilled with purged sorbent. The compartment access port on the back of the sampler provides for easy and direct transfer of sorbent to a thermal desorption tube in a laboratory. 1. Sample Collection Remove the sampler from the resealable pouch. Record sample ID number, sampling location, and date on the pouch. Sampler ID label Prepare the passive sampler for sampling. For Prefilled ULTRA: Slide sampler cover to open position (diffusion holes visible). Write the sample start time on the pouch label. User-filled ULTRA Passive Samplers Sorbent for the ULTRA Sampler is provided separately in glass vials with PTFE lids to maintain low sorbent background. The sampler's compartment access port and transfer funnel accessory allow the user to transfer purged sorbent from the vial directly into the housing before sampling. After sampling, the user either ships the sample sorbent in the sampler or transfers the sorbent back into the vial for shipment. Samplers or vials are shipped to a laboratory for thermal desorption and analysis. Diffusion holes (sample sorbent compartment) Clip Blank/ correction sorbent compartment Sliding cover in open position Publication 1744 Rev 1503 SKC Inc. 724-941-9701 SKC South 434-352-7149 SKC Gulf Coast 281-859-8050 www.skcinc.com SKC-West 714-992-2780 Sampling with ULTRA Passive (Diffusive) Samplers For User-filled ULTRA: Using the Transfer Funnel accessory, transfer sorbent from vial to sampler. Slide sampler cover to open position (diffusion holes visible). Write the sample start time on pouch label. 2. Sampler Storage and Shipment to Analytical Laboratory Before Sampling: Prefilled: 30 days (except charcoal - 6 months) in a clean, organic solvent-free environment User-filled: 60 days (except charcoal - 1 year) in a clean, organic solvent-free environment After Sampling: 21 days at ≤ 39.2 F (4 C) in a clean, organic solvent-free environment When sampling is completed, slide sampler cover to closed position. Sample compartment 3. Critical Information to Include in Sample Shipment The laboratory will need to know the air volume for the chemical of interest. Calculate as follows: Clip Blank/ correction compartment Carefully package sealed pouch(es) containing sampler(s) or sorbent vial(s) and blank(s). Use expedited shipping to ship sample(s) and Chain of Custody Form(s) to a laboratory for analysis. Chemical sampling rate supplied by SKC (ml/min) X Sampling time (min) = Air volume (ml or L) Sliding cover in closed position For Prefilled ULTRA: Write the sample stop time on the pouch label. Ensure ID number on sampler matches ID number on pouch and place sealed sampler in resealable pouch. The laboratory will determine the total micrograms (μg) found on the sampler for the chemical of interest. The air volume will be used to report the chemical concentration in air as ppb or ppt. For User-filled ULTRA: Write the sample stop time on the pouch label. a. Ensure ID number on sampler matches ID number on pouch and place sealed sampler in resealable pouch. Or b. Transfer sorbent from the sampler body into a vial and place vial in envelope. 4. Analysis Thermal desorption (TD) followed by analysis using gas chromatography (GC) with a detector specified in the method for the compound of interest. See Analysis Instructions at www.skcinc.com/instructions/40125.pdf or www.skcinc.com/ instructions/40127.pdf (charcoal). References 1 SKC Update to EPA Method TO-17 available at www.skcinc.com Copyright 2007 - 2015 Notice: This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures. Publication 1744 Rev 1503 SKC Inc. 724-941-9701 SKC South 434-352-7149 SKC Gulf Coast 281-859-8050 www.skcinc.com SKC-West 714-992-2780
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Print high-res Author : SKC Inc. Create Date : 2015:03:30 14:29:28-04:00 Keywords : Sampling, with, ULTRA, Passive, (Diffusive), Samplers, Sample, Setup, Guide, Publication, 1744, PDF, Document Modify Date : 2015:03:30 14:36:01-04:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Title : Sampling with ULTRA Passive (Diffusive) Samplers Sample Setup Guide Publication 1744 PDF Document Creator : SKC Inc. Description : Sampling with ULTRA Passive (Diffusive) Samplers Sample Setup Guide Publication 1744 PDF Document Subject : Sampling with ULTRA Passive (Diffusive) Samplers Sample Setup Guide Publication 1744 PDF Document Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2015:03:30 14:36:01-04:00 Producer : Acrobat Distiller 10.1.13 (Windows) Document ID : uuid:50f23f3f-bf50-438b-b526-a084b6dc96f8 Instance ID : uuid:d15a4e58-5e72-4b26-a6fb-e213708c4dcf Page Count : 2EXIF Metadata provided by EXIF.tools