3002 DVA_ib DVA Ib
User Manual: 3002-DVA_ib
Open the PDF directly: View PDF .
Page Count: 9
Download | |
Open PDF In Browser | View PDF |
I R T Electronics Pty Ltd A.B.N. 35 000 832 575 26 Hotham Parade, ARTARMON N.S.W. 2064 AUSTRALIA National: Phone: (02) 9439 3744 Fax: (02) 9439 7439 International: +61 2 9439 3744 +61 2 9439 7439 Email: sales@irtelectronics.com Web: www.irtelectronics.com IRT Eurocard Types DVA-3002 Serial Digital VDA Designed and manufactured in Australia IRT can be found on the Internet at: http://www.irtelectronics.com 3002-dva.ib.doc Page 1 of 8 16/07/2002 DVA-3002 Serial Digital VDA Instruction Manual Table of Contents Section Page Operational Safety General Description Applications Specifications Circuit description Installation Front and rear layouts Maintenance & Storage Warranty and service Equipment return Drawing list index 2 3 3 4 5 5 6 7 7 7 8 This instruction manual applies to DVA-3002 assembly 804048 units later than S/N 9710001 Operational Safety: WARNING Operation of electronic equipment involves the use of voltages and currents that may be dangerous to human life. Note that under certain conditions dangerous potentials may exist in some circuits when power controls are in the OFF position. Maintenance personnel should observe all safety regulations. Do not make any adjustments inside equipment with power ON unless proper precautions are observed. All internal adjustments should only be made by suitably qualified personnel. All operational adjustments are available externally without the need for removing covers or use of extender cards. 3002-dva.ib.doc Page 2 of 8 16/07/2002 General Description The IRT DVA-3002 is a one in eight out distribution amplifier for SMPTE/EBU serial digital video signals. The DVA-3002 features an input circuit with automatic cable equalisation for Belden 8281 or PFS1/2 coaxial cable and cable driver circuits for nine individually sourced outputs, eight outputs are provided on the rear connector panel and the ninth output is a monitoring output on the front panel of the unit. The input cable equaliser circuit incorporates a carrier detection circuit to mute the output when no signal is applied to the unit. The DVA-3002 uses the carrier detect signal to energise a relay when carrier is present, the relay contacts are connected to SK10 on the rear panel to give a failure alarm in the form of a make (or break) to ground on failure as set by LK1 on the circuit board. The DVA-3002 is built in a 3U extended Eurocard 220 mm x 100 mm modules designed to mount in the IRT FR700, FR-722A, FR-748 and FRU-1030 family of Eurocard frames. Applications The DVA-3002 is intended to be used where multiple signal outputs are required from equipment with only one output and to provide input cable equalisation for devices not having this feature as most unequalised inputs will only support input signal cable lengths of less than 20 metres. Frequent reclocking of a serial digital signal can lead to increased jitter and unnecessary increased cost, complexity and transit time in circuits. The DVA-3002 is therefore the unit of choice where reclocking of the signal is provided by the destination equipment or otherwise where reclocking is not deemed necessary. 3002-dva.ib.doc Page 3 of 8 16/07/2002 Technical specifications DVA-3002 Input: Number Impedance Return loss 1. 75 Ohm. >15 dB 5 MHz to 360 MHz. Outputs: Number Signal level Impedance Return loss DC offset 9. 800 mV ± 10% 75 Ohm. >15 dB 5 MHz to 360 MHz. Nil. Performance: Cable compensation Output rise time Automatic, better than 300 metres at 270 Mb/s for Belden 8281 or PSF1/2 cable. <1 ns, (700 ps typically). Connectors: BNC. Indicators: Power Signal present Signal fail (relay contacts) LED (green) for +5v. LED (green) for signal present. Rear panel SK10 (pins 1 and 2) Power requirement: Voltage Consumption 28 Vac CT (14-0-14 Vac) or ±16 Vdc. 2.5 VA (<90 mA). General: Temperature range 0 - 50° C ambient Mechanical Suitable for mounting in IRT 19" rack chassis types FR-700 & FR-722 with input, output and power connections to the rear. 6 HP x 3U Extended Eurocard (220 mm x 100 mm). With rear assembly 330g. Size Weight Finish: Front panel Rear assembly Standard accessories: 3002-dva.ib.doc Grey enamel, silk screened black lettering & red IRT logo. Detachable silk screened PCB with direct mount connectors to Eurocard and external signals. Rear connector assembly (supplied with module). Page 4 of 8 16/07/2002 Circuit Description The input circuit of the DVA-3002 consists of U1 a CLC014 adaptive cable equaliser IC, which automatically adapts to equalise any cable length from zero metres to lengths that attenuate the signal by 40 dB at 200 MHz. This corresponds to 300 metres of Belden 8281 cable. A carrier detect and output mute circuit in the CLC014 is used to mute the output when no signal is present. The CLC014 is insensitive to the pathological patterns that can be present in the serial digital video signal. The DVA-3002 also features an OUTPUT MONITOR point on the front panel. The output monitor is a isolated copy of the signal present at the rear panel outputs. The output of the CLC014 input stage is coupled to U2, U3 and U5 CLC007 cable driver circuits to provide the nine isolated outputs from the DVA-3002. Note the cable driver outputs are complementary signals thus signal inversion can occur between the input and three of the outputs of the DVA-3002. The input cable equaliser circuit U1 incorporates a carrier detection circuit to mute the output when no signal is applied to the unit. The carrier detect signal energises relay RL1 via inverter Q1 when carrier is present, the relay contacts are connected to SK10 on the rear panel to give a failure alarm in the form of a make (or break) to ground on failure as set by LK1 on the circuit board. The dual AC inputs are rectified by D1 to D4, and then regulated in a LM2575-5 switch mode regulator circuit U4 to provide the +5V operating voltage for the unit. Installation Handling: The DVA-3002 contains static sensitive devices and proper static free handling precautions should be observed. When individual modules are stored, they should be placed in antistatic bags and proper antistatic procedures should be followed when inserting and removing cards from these bags. Power: Ensure that the voltage selection of the IRT mounting frame used to house the DVA-3002 and the local AC mains supply voltage match and that the correct rating fuse is installed in the mounting frame power supply. Earthing: Chassis earth connection of the equipment mounting frame is via the earth connection on the three pin (IEC) AC mains supply inlet. This is a safety earth and must be connected. Installation in frame or chassis: See details in separate manual for selected frame type. LK1 is factory set for a contact make to ground on signal failure at SK10 pin 2 on the rear panel, move LK1 from the normally closed (N/C) to the normally open (N/O) position for a break to ground on signal or power loss. The presence of signal is indicated by the ‘SIGNAL PRESENT’ front panel LED (green). The presence of the internal +5 Vdc supply is indicated by the front panel LED (green). It is recommended that unused outputs on the rear panel be terminated with 75 ohm termination plugs. 3002-dva.ib.doc Page 5 of 8 16/07/2002 Front & rear panel connector diagrams The following front panel and rear assembly drawings are not to scale and are intended to show connection order and approximate layout only. 3002 DV A-3 0 0 2 1 OUTPUTS 2 3 4 SIGNAL PRESENT 5 6 7 8 OUTPUT MON DC 2 1 INPUT 1 = GND 2 = ALARM N140 3002-dva.ib.doc Page 6 of 8 16/07/2002 Maintenance & storage Maintenance: No regular maintenance is required. Care however should be taken to ensure that all connectors are kept clean and free from contamination of any kind. This is especially important in fibre optic equipment where cleanliness of optical connections is critical to performance. Storage: If the equipment is not to be used for an extended period, it is recommended the whole unit be placed in a sealed plastic bag to prevent dust contamination. In areas of high humidity a suitably sized bag of silica gel should be included to deter corrosion. Where individual circuit cards are stored, they should be placed in antistatic bags. Proper antistatic procedures should be followed when inserting or removing cards from these bags. Warranty & service Equipment is covered by a limited warranty period of three years from date of first delivery unless contrary conditions apply under a particular contract of supply. For situations when “No Fault Found” for repairs, a minimum charge of $A100.00 will apply, whether the equipment is within the warranty period or not. Equipment warranty is limited to faults attributable to defects in original design or manufacture. Warranty on components shall be extended by IRT only to the extent obtainable from the component supplier. Equipment return: Before arranging service ensure that the fault is in the unit to be serviced and not in associated equipment. If possible, confirm this by substitution. Before returning equipment contact should be made with IRT or your local agent to determine whether the equipment can be serviced in the field or should be returned for repair. The equipment should be properly packed for return observing antistatic procedures. The following information should accompany the unit to be returned: 1. 2. 3. 4. 5. 6. 7. A fault report should be included indicating the nature of the fault The operating conditions under which the fault initially occurred. Any additional information which may be of assistance in fault location and remedy. A contact name and telephone and fax numbers. Details of payment method for items not covered by warranty. Full return address. For situations when “No Fault Found” for repairs, a minimum charge of $A100.00 will apply, whether the equipment is within the warranty period or not. Please note that all freight charges are the responsibility of the customer. The equipment should be returned to the agent who originally supplied the equipment or, where this is not possible, to IRT direct as follows. Equipment Service IRT Electronics Pty Ltd 26 Hotham Parade ARTARMON N.S.W. 2064 AUSTRALIA Phone: Email: 3002-dva.ib.doc 61 2 9439 3744 service@irtelectronics.com Page 7 of 8 Fax: 61 2 9439 7439 16/07/2002 Drawing List Index Drawing # Sheet # Description 804048 1 DVA-3002 serial digital VDA schematic diagram. 3002-dva.ib.doc Page 8 of 8 16/07/2002 SK1 1 2 3 L1/RA EYE MON TP1 26a,b 25a,b 24a,b 23a,b 22a,b 21a,b 31a,b 30a,b 29a,b 28a,b 1 1 51 R5 (J1/P1) 100n C7 10uF C5 10nF C4 4u7 100n C32 FL4 DSS306 1 1 PCB 804049R +5 DSS306 FL2 3 C9 100pF 100n DSS306 FL1 C8 C6 100pF 68R R27 3 FL3 DSS306 J2/RA optional power in [used when fitted to FR-722A or FRU-1030 frame] J2 INPUT MON. O/P SK11 150 R28 2 2 3 3 L3 7 6 5 4 3 2 1 4 3 2 1 4R7 F4 4R7 F3 4R7 F2 4R7 F1 2 2 2 2 10nF DO DO VEE IN- IN+ VCC 1N4004 D4 1N4004 D3 1 0R0 0R0 JP2 R3 120 C3 100n 2 +5 100 R25 C2 100n 0R0 R1 75 C1 100n R2 100 C24 10nF C33 4u7 JP1 1 1 1 8 9 10 11 12 13 14 5 6 7 8 JP3 1N4004 D2 1N4004 D1 DI DI Vee Vee MUTE CLC014AJE AEC- AEC+ CD Vcc OEM Vcc Vcc U1 CLC007AJE Q1 Q1 Q0 Q0 U5 L5 470nH 1 100 C26 1000uF BAS32 C25 10nF D6 R26 R8 75 C27 100uF 1 I O F R14 100 R11 100 U4 LM2575-5.0 R10 75 G 3 C30 EN 5 10nF 2 4 1 2 C28 220uF 22uH 330uH D5 1N5822 L2 C14 10nF C12 10nF C11 10uF +5V TP2 L1 R13 100 R12 100 L4 470nH +5 +5V C15 100pF 8 7 6 5 C29 220uF R23 820 (DC IND.) LD1 LDGRN Q0 +5 Q0 VCC Q1 IN+ IN- VEE Q1 Q0 Q0 Q1 Q1 U3 CLC007AJE VCC IN+ IN- VEE U2 CLC007AJE C13 100pF +5 8 7 6 5 1 2 3 4 1 2 3 4 R7 10K 22K R6 R24 820 LD2 LDGRN (SIGNAL PRESENT) +5 2 1 +5 D7 4u7 C23 4u7 C22 4u7 C21 4u7 C20 4u7 C19 4u7 C18 4u7 C17 4u7 C16 BAS32 C34 2 2 68 68 68 68 68 R18 R19 R20 R21 R22 5 2 30-06-97 Date: 23-Mar-2001 Revision: 2 ENG. APP. K.N. 32b L2/RA L3/RA L4/RA L6/RA L5/RA L7/RA 804048 Sheet 1 of 3 DVA-3002 SERIAL DIGITAL VIDEO DISTRIBUTION AMPLIFIER Drawing No. Title SK10 IRT Electronics Pty. Ltd. ARTARMON NSW AUSTRALIA 2064 SCALE N.T.S. A3 SIZE 3 2 1 SK2 SK3 SK4 SK6 SK5 SK7 SK8 SK9 OUTPUTS L8/RA L9/RA TO GROUND ON ALARM, AS SET BY LK1 DO NOT COPY NOR DISCLOSE TO ANY THIRD PARTY WITHOUT WRITTEN CONSENT CHECKED 2 27a,b 20a,b 19a,b 18a,b 17a,b 16a,b 15a,b 14a,b 13a,b 12a,b 11a,b 10a,b 9a,b 8a,b 7a,b 6a,b 5a,b 4a,b 3a,b 2a,b ALARM CIRCUIT n.o. 10 1 LK1 n.c. (P1/J1) 1a,b CONTACT CLOSURE (OR BREAK) V23026 RL1 COPYRIGHT Q1 BC846 4u7 RL1 DRAWN C10 10nF 1 68 R17 C35 68 R16 +5 68 R15 1 3 C31 2 1 3 8 3 2 1 2 1 29-01-97
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2002:07:16 10:30:50 Producer : Acrobat Distiller 4.05 for Windows Modify Date : 2002:07:16 10:35:54+11:00 Page Count : 9EXIF Metadata provided by EXIF.tools