ACCULINK® 3172 and 3174
E1 DSU/CSU
Quick Reference
Document No. 3170-A2-GL10-20

Copyright © 2002 Paradyne Corporation.
All rights reserved.
Printed in U.S.A.

Warranty, Sales, Service, and Training Information
Contact your local sales representative, service representative, or distributor directly for
any help needed. For additional information concerning warranty, sales, service, repair,
installation, documentation, training, distributor locations, or Paradyne worldwide office
locations, use one of the following methods:

„
„

Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure
to register your warranty at www.paradyne.com/warranty.)
Telephone: Call our automated system to receive current information by fax or to
speak with a company representative.
—

Within the U.S.A., call 1-800-870-2221

—

Outside the U.S.A., call 1-727-530-2340

Document Feedback
We welcome your comments and suggestions about this document. Please mail them to
Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or
send e-mail to userdoc@paradyne.com. Include the number and title of this document
in your correspondence. Please include your name and phone number if you are willing
to provide additional information.

Trademarks
ACCULINK is a registered trademark of Paradyne Corporation. All other products and
services mentioned herein are the trademarks, service marks, registered trademarks, or
registered service marks of their respective owners.

ACCULINK® 3172 and 3174 E1 DSU/CSU
Quick Reference
Document Number 3170-A2-GL10-20
October 2002

Product Documentation Online
Complete documentation for this product is available at www.paradyne.com.
Select Library → Technical Manuals → T1/E1 Digital Access Devices.
Select the following document:
3170-A2-GB20
ACCULINK 3172 and 3174 E1 DSU/CSU Operator’s Guide
To request a paper copy of a Paradyne document:

„
„

Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396)
Outside the U.S.A., call 1-727-530-8623

Before installing the DSU/CSU, read the Important Safety Instructions on page 16. Also,
to ensure compliance with emissions requirements, install ferrite chokes as described in
Quick Start Procedure on page 2.

1

Quick Start Procedure
The following procedure is for experienced DSU/CSU users who are familiar with the
317x DSU/CSU installation process and have no special requirements for their
application. See the ACCULINK 3172 and 3174 E1 DSU/CSU Operator’s Guide for
more information.

Procedure
1. If you intend to use a 24 or –48 VDC power supply, see the Operator’s Guide. A
power cable appropriate to the country of installation is shipped with the DSU/CSU
or is available from your sales representative. Use the power cable to connect the
power supply to a grounded AC power outlet. Plug the output cable of the power
supply into the POWER jack on the back panel of the DSU/CSU.
2. Attach the DSU/CSU network connection to the E1 network using the appropriate
cable. Attach the DSU/CSU to the customer premises equipment via the DTE and
port connectors.
3. Install ferrite chokes on cables attached to Ports 1 and 2 (Model 3172) or Ports 1–4
(Model 3174):
—

Pull up on the latch to open
the ferrite choke.

—

Place the ferrite choke on the
cable as close to the
DSU/CSU as possible.

—

Close the choke around the
cable and press down on the
latch to fasten it.

—

Secure the choke with a cable
tie.

Ferrite Choke

Connector
End

Tie
Wrap

Plastic
Latch

97-14820-02

4. If you intend to use front panel emulation, connect the cable from the PC to the
COM port on the rear panel of the DSU/CSU.
5. Power on the DSU/CSU to perform the power-up self-test.
6. During the power-up self-test, the FAIL LED flashes, then all LEDs blink twice.
When the test is complete, verify that the DSU/CSU is functional by observing that
the OK, NETWORK SIG, and DTE SIG LEDs are lit.
7. If you intend to manage the DSU/CSU with SNMP, cable either the COM or AUX
port (as appropriate for your configuration). Then, configure the SNMP
management link.
8. If you do not intend to use the DTE Drop/Insert E1 port, disable it using the
configuration procedures in Operation and Configuration Options of the Operator’s
Guide. (The default setting for this port is Enabled.)
9. Configure the ports and channels you intend to use and assign channels to the
network interface.
2

Cabling Examples
The DSU/CSU is supplied with an AC power module. You must provide the DTE and
network cables.
Optional cables that you can order from the company are described in Pin Assignments
in the Operator’s Guide.

NOTE:
The 120Ω/75Ω switch selects either the 120-ohm balanced network interface or the
75-ohm unbalanced network interface. The RX SHIELD switch selects either an
“open” or “earth” shield connection for the 75-ohm RX interface. (This switch must
be set to “open” when using the 120-ohm interface.)
COM PORT

NETWORK
NETWORK

POWER

AUX
PORT

COM
PORT

TX

NETWORK
RX SHIELD

DTE

120ý

CAUTION: AUX PORT OR COM PORT MUST NOT BE
CONNECTED TO PSTN OR E1 NETWORK

CLOCK IN

PORT 1

FRONT
PANEL

RX

75ý

120ý

OPEN

75ý

EARTH

75ý

PORT 2

3100-F1-550

DSU/CSU
DSU/CSU
SERIAL
PORT

NETWORK

TO AC
POWER
MODULE

COM PORT
NOTE:
3100 SERIES
FRONT PANEL
EMULATION
SOFTWARE,
3100-C1-010

POWER

AUX
PORT

COM
PORT

TX

NETWORK

CAUTION: AUX PORT OR COM PORT MUST NOT BE
CONNECTED TO PSTN OR E1 NETWORK

RX

RX SHIELD

DTE

CLOCK IN

120ý

75ý

120ý

OPEN

75ý

EARTH

PORT 3

PORT 4

PORT 1

PORT 2

75ý

DSU/CSU

1-540
3100-F

TO DC
POWER
(OPTIONAL)

NETWORK

3100-F1-520

SNMP
MANAGER

OR

98-14673a

3

Configuration Options
Configuration options are accessed from the Cnfig branch of the front panel menu.
DSU E1 CEPT

Stat

Test

Lpbk

STest TStat
ID
DevHs Perf
LED

Rlpbk

Ctrl

Cnfig

Lamp

LED

Ptrns

Rel

Reset
DL
ClrReg
CID

E1 Prtn
Abort Send
NET

Prtn
Near

DCLB DCLB
UP
DN

511

Far

Mon

NET Prt1 Prt2 Prt3 Prt4

QRSS
1in8

Near

QRSS 511
Cur 8Tot Intvl
Cur 24Tot Intvl

Abort PLB RLB DTLB
LLB DLB DCLB

Far

DTE Prt2 Prt4
Prt1 Prt3

Load Edit Area From:

Activ

Cust1 Cust2

Fact

Choose Function:
Save

Edit
DTE

NET
Port

Gen
Chan

Dsply

DTE

Prt2

Clear Prt1
Prt1
Copy

Alarm
User

Prt4

SNMP

Activ
Cust2
Cust1

Gen Trap

Prt3

Prt3
Prt2

Prt4

Port Select :
All

98-14606a

Prt1 Prt2 Prt3 Prt4

4

Factory default configuration options are shown in boldface type in the following tables.

Table 1. DTE Interface Configuration Options
Option

Factory

Comments/Description

DTE Port:

Enab

Enables the use of the DTE Drop/Insert port.

Disab
DTE Frame:

CRC4

Selects framing format.

noCRC
DTE Coding:

AMI

Selects line coding format.

HDB3
Extrn DLB:
(External DTE
Loopback)

Enab

Send Ones:

Enab

Allows control of DLB on external contact
closure.

Disab
Sends all ones on channels allocated to the
network E1 on LOS, LOF, or AIS.

Disab

Table 2. Port Configuration Options (1 of 3)
Option

Factory

Comments/Description

Port Type:

E530

Selects the port type: EIA-530A, V.35, RS449,
or X.21.

V.35
RS449
X.21
Base Rate:

Nx64

Enables the port to either Nx56 or Nx64 rates.

Nx56
Net DCLB:

Enab

Network-initiated DCLB, allows DCLB to be
controlled by inband V.54 codes.

Disab

5

Table 2. Port Configuration Options (2 of 3)
Option

Factory

Comments/Description

Port LB:

Disab

Port-initiated Loopbacks, allows Loopbacks to
be initiated through the port by the external
DTE.

DTLB
DCLB
Both
All Ones:

Disab

All ones sent to network (DTE) E1 when DTR
or RTS interrupted.

DTR
RTS
Both
Rcv RAI:
(Action on Received
Remote Alarm
Indication)

None

Tx Clock:

Int

Data port remains enabled, or is disabled, on
receiving RAI on the network interface.

Halt

Selects whether the transmitted data clock is
internal (TXC) or external (XTXC).

Ext
InvertTxC:
(Invert Tx Clock)

Enab

Selects phase inversion of the transmit clock
(TXC).

Disab
InvertData:

Enab

Allows the data on the port to be inverted.

Disab
EDL:

Enab

Specifies whether the Embedded Data Link is
enabled.

Disab
Err Rate:
(Excessive Error
Rate)

10E-4

Selects the error rate threshold for Excessive
Error Rate Alarm.

10E-5
10E-6
10E-7
10E-8
10E-9

6

Table 2. Port Configuration Options (3 of 3)
Option

Factory

Comments/Description

Near-end:

Disab

Specifies whether the device will maintain
near-end performance statistics.

Maint
Send
Both
Far-end:

Disab

Specifies whether the device will maintain
far-end performance statistics.

Maint
Mgmt Link:

Enab

Specifies whether the EDL Management Link is
enabled.

Disab

Table 3. Network Interface Configuration Options
Option

Factory

Comments/Description

NET Frame:

CRC4

Selects framing format.

noCRC
Mgmt Link:

Disab

Specifies whether the FDL’s Management Link
is enabled.

SNMP
Circuit Ident:

Edit

Specifies the transmission vendor’s circuit
identifier.

Clear

7

Table 4. DTE Channel Configuration Options
Option

Factory

Comments/Description

DTE Channels:

TS16

Selects TS16 for signaling or
assigns DS0 channels on the
DTE Drop/Insert interface to
DS0 channels on the
network interface.

Assign

TS16:

Data

Specifies whether time
slot 16 is reserved for
signaling information or
available for data.

Rsvd

Line 1 Displays:
N1 N2 N3 ......
N24:

Line 2
Displays:

Meaning

Comments/Description

—

Unassigned

D1, D2 ... D24

Channel
assigned to this
DTE channel

Function key under the
channel (N1, N2, etc.)
selects the DTE channel to
assign (D1 through D24,
or –).

Prt1
Prt2
Prt3
Prt4

Channel
assigned to port
1, 2, 3, or 4

8

Table 5. Data Port Channel Configuration Options (1 of 2)
Option

Factory

Comments/Description

Assign To:

NET

Assigns this port to channels on the Network
or DTE Drop/Insert interface, or to another
port.

DTE
Prtn
Assign By:

Block

Determines how channels are assigned:
contiguous blocks or individual channels.

Chan
Port Rate:

64 (56)
128 (112)
192 (168)
256 (224)
320 (280)
384 (336)
448 (392)
512 (448)
576 (504)
640 (560)
704 (616)
768 (672)
832 (728)
896 (784)
960 (840)
1024 (896)
1088 (952)
1152 (1008)
1216 (1064)
1280 (1120)
1344 (1176)
1408 (1232)
1472 (1288)
1536 (1344)
1600 (1400)
1664 (1456)
1728 (1512)
1792 (1568)
1856 (1624)
1920 (1680)
1984 (1736)

Selects the data rate for the port.
The possible rates depend on whether the
port is configured for Nx56 or Nx64.
This configuration option only appears if the
“Assigned By” configuration option is Block.

NOTE: Configuration options in this table are made available after Prtn (where n is 1
or 2 for the Model 3172 and 1, 2, 3, or 4 for the Model 3174) is selected from the
Channel Config screen.

9

Table 5. Data Port Channel Configuration Options (2 of 2)
Option

Factory

Comments/Description

Start At:

Clear

Clears (unassigns) channels for this port.

N1 (D1)
N2 (D2)
N3 (D3)
•
•
•
N31 (D31)

This configuration option appears if the
“Assigned By” configuration option is Block or
ACAMI.

Line 1 Displays:
N1 N2 N3... N31:
(If assigned to NET)
D1 D2 D3... D31:
(If assigned to DTE)

Line 2
Displays:
—
Prt1, Prt2,
Prt3, Prt4
D1, D2... D31
N1, N2... N31

Comments/Description
This configuration option appears if the
“Assigned By” configuration option is
individual channels (Chan).

Function key under the channel (N1, N2 etc.)
assigns (unassigns) port (1, 2, 3, or 4) to that
channel.

NOTE: Configuration options in this table are made available after Prtn (where n is 1
or 2 for the Model 3172 and 1, 2, 3, or 4 for the Model 3174) is selected from the
Channel Config screen.

10

Table 6. General Configuration Options
Option

Factory

Comments/Description

Pri Clk Src:

NET

Selects the primary clock source for the
DSU/CSU.

DTE
Prtn
Int
Ext
Sec Clk Src:

NET
DTE

Selects the secondary clock source for the
DSU/CSU, used in the event of failure of the
primary source.

Prtn
Int
Ext
Clock Rate:

2048

Selects the clock rate of the source if external.

8

Table 7. User Configuration Options (1 of 2)
Option

Factory

Comments/Description

Self-Test:

Enab

Allows bypass of self-test on initialization.

Disab
Com Use:

SNMP

Controls how the COM port is used.

ASCII
Daisy
Com Type:

Async

Controls whether the COM port is synchronous
or asynchronous.

Sync
Com Clk:

Int

Controls whether the COM port uses an
internal or external clock.

Ext

11

Table 7. User Configuration Options (2 of 2)
Option

Factory

Comments/Description

Com Rate:
(Communication Port
Rate)

1.2

Selects the bit rate for the COM port.

2.4
4.8
9.6
14.4
19.2
38.4

Char Length:

7

Selects the character length for the COM port.

8
CParity:
(Communication Port
Parity)

None

Selects the parity for the COM port.

Even
Odd

CStop Bits:
(Communication Port
Stop Bits)

1

Selects the number of stop bits for the COM
port.

1.5
2

Ignore DTR:

Yes

Specifies whether the COM port ignores DTR.

No
Aux Use:

None

Controls how the auxiliary port is used.

SNMP
Daisy
Aux Rate:

9.6

Configures the bit rate for the auxiliary port.

14.4
19.2
38.4

12

Table 8. Alarm Configuration Options
Option

Factory 1

Comments/Description

Alrm Msg:

Enab
Disab

Determines whether alarm messages are
routed to the ASCII terminal or printer attached
to the COM port.

Enab

Sends SNMP traps.

SNMP Trap:

Disab

Table 9. General SNMP Configuration Options (1 of 2)
Option

Factory

Comments/Description

System Name:

Edit

The SNMP system name for this device.

Clear
System Location:

Edit

The SNMP system location for this device.

Clear
System Contact:

Edit

The SNMP system contact name for this
device.

Clear
CommunityName1:

Edit

A community name that is allowed access to
this device. Defaults to public.

Clear
Access 1:

Read

The type of access allowed for community
name 1.

R/W
CommunityName2:

Edit

A community name that is allowed access to
this device.

Clear
Access 2:

Read

The type of access allowed for community
name 2.

R/W
IP Adr:

Edit

The IP address needed to access the device.

Clear
NetMask:

Edit

The Subnet Mask needed to access the device.

Clear
13

Table 9. General SNMP Configuration Options (2 of 2)
Option

Factory

Comments/Description

Com IP Adr:

Edit

The IP address for the COM port when the
COM port is configured for SNMP.

Clear
Com NetMask:

Edit

The Subnet Mask needed to access the device
when the COM port is configured for SNMP.

Clear
Com Link:

PPP

The link layer protocol for the COM port when
the COM port is configured for SNMP.

SLIP
Aux IP Adr:

Edit

Specifies the IP address of the AUX port when
the AUX port is configured for SNMP.

Clear
Aux NetMask:

Def Netwk:

Edit
Clear

Specifies the Subnet Mask needed to access
the device when the AUX port is configured for
SNMP.

None

Specifies the default network destination.

Com
Aux
FDL
EDLn

14

Table 10. SNMP Trap Configuration Options
Option

Factory 1

Comments/Description

Num Trap Mgrs:

1
2–6

The number of trap managers supported by the
device.

Trapn IP Adr:

Edit

Specifies the IP address for each trap manager.
This configuration option is repeated for all
n managers.

Clear
Trapn Dst:

None

Specifies the network destination for Trap
Manager n.

Com
Aux
FDL
EDLn
Gen Trap:

Disab

Specifies the general trap types to enable:
WarmStart, Authentication Failure or both.

Warm
Auth
Both
Entp Trap:

Enab

Specifies whether the EnterpriseSpecific trap
type is enabled.

Disab
Link Trap:

Disab

Specifies the link trap type to enable: Trap on
Link Up, Link Down, or both.

Up
Down
Both
Trap I/F:

NET

When any link trap types are enabled, specifies
which links to send traps for.

DTE
E1s
Ports
All

15

!

Important Safety Instructions

1. Read and follow all warning notices and instructions marked on the product or
included in the manual.
2. This product is intended to be used with a 3-wire grounding type plug – a plug
which has a grounding pin. This is a safety feature. Equipment grounding is vital to
ensure safe operation. Do not defeat the purpose of the grounding type plug by
modifying the plug or using an adapter.
Prior to installation, use an outlet tester or a voltmeter to check the AC receptacle
for the presence of earth ground. If the receptacle is not properly grounded, the
installation must not continue until a qualified electrician has corrected the problem.
If a 3-wire grounding type power source is not available, consult a qualified
electrician to determine another method of grounding the equipment.
3. Slots and openings in the cabinet are provided for ventilation. To ensure reliable
operation of the product and to protect it from overheating, these slots and
openings must not be blocked or covered.
4. Do not allow anything to rest on the power cord and do not locate the product where
persons will walk on the power cord.
5. Do not attempt to service this product yourself, as opening or removing covers may
expose you to dangerous high voltage points or other risks. Refer all servicing to
qualified service personnel.
6. General purpose cables are provided with this product. Special cables, which may
be required by the regulatory inspection authority for the installation site, are the
responsibility of the customer.
7. When installed in the final configuration, the product must comply with the
applicable Safety Standards and regulatory requirements of the country in which it
is installed. If necessary, consult with the appropriate regulatory agencies and
inspection authorities to ensure compliance.
8. A rare phenomenon can create a voltage potential between the earth grounds of
two or more buildings. If products installed in separate buildings are
interconnected, the voltage potential may cause a hazardous condition. Consult a
qualified electrical consultant to determine whether or not this phenomenon exists
and, if necessary, implement corrective action prior to interconnecting the products.
9. Input power to the AC voltage configuration of this product must be provided by one
of the following: (1) a UL Listed/CSA certified power source with a Class 2 or
Limited Power Source (LPS) output for use in North America, or (2) a certified
power source with a Safety Extra Low Voltage (SELV) output for use in the country
of installation.
Input power to the DC voltage configurations of this product must be provided by
one of the following: (1) a National Electric Code (NEC)/Canadian Electric Code
(CEC) Class 2 circuit for use in North America, or (2) a certified Safety Extra Low
Voltage (SELV) circuit input for use in the country of installation.

16

10. In addition, if the equipment is to be used with telecommunications circuits, take the
following precautions:
—

Never install telephone wiring during a lightning storm.

—

Never install telephone jacks in wet locations unless the jack is specifically
designed for wet locations.

—

Never touch uninsulated telephone wires or terminals unless the telephone line
has been disconnected at the network interface.

—

Use caution when installing or modifying telephone lines.

—

Avoid using a telephone (other than a cordless type) during an electrical storm.
There may be a remote risk of electric shock from lightning.

—

Do not use the telephone to report a gas leak in the vicinity of the leak.

EMI Notices
! UNITED STATES – EMI NOTICE:
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user
will be required to correct the interference at his own expense.
The authority to operate this equipment is conditioned by the requirements
that no modifications will be made to the equipment unless the changes or
modifications are expressly approved by Paradyne Corporation.

! CANADA – EMI NOTICE:
This Class A digital apparatus meets all requirements of the Canadian
interference-causing equipment regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du
règlement sur le matérial brouilleur du Canada.

17

CE Marking
Models 3172-A1-410 and 3174-A1-410 of this product are marked with the CE mark.
This mark has been affixed to demonstrate full compliance with the following European
Directives:

„
„
„

Directive 73/23/EEC – Council Directive of 19 February 1973 on the harmonization
of the laws of the member states relating to electrical equipment designed for use
within certain voltage limits, as amended by Directive 93/68/EEC.
Directive 89/336/EEC – Council Directive of 3 May 1989 on the approximation of
the laws of the member states relating to Electro-Magnetic Compatibility (EMC), as
amended by Directive 93/68/EEC.
Directive 91/263/EEC – Council Directive of 29 April 1991 on the approximation of
the laws of the member states concerning telecommunication terminal equipment,
including the mutual recognition of their conformity, as amended by Directive
93/68/EEC. The application of this directive is in relation only to network connection
via the 120-ohm G.703 interface as specified in CTR12.

Warranty, Sales, Service, and Training Information
Contact your local sales representative, service representative, or distributor directly for
any help needed. For additional information concerning warranty, sales, service, repair,
installation, documentation, training, distributor locations, or Paradyne worldwide office
locations, use one of the following methods:

„
„

Internet: Visit the Paradyne World Wide Web site at www.paradyne.com.
(Be sure to register your warranty at www.paradyne.com/warranty.)
Telephone: Call our automated system to receive current information via fax or to
speak with a company representative.
—

Within the U.S.A., call 1-800-870-2221

—

Outside the U.S.A., call 1-727-530-2340

   

*3170-A2-GL10-20*

18







Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Producer                        : Acrobat Distiller 4.05 for Windows
Creator                         : FrameMaker 6.0
Modify Date                     : 2002:10:15 10:24:58-04:00
Keywords                        : ACCULINK, DSU/CSU, CSU/DSU, DSU, CSU, 3170, 3172, 3174, 3100, E1
Author                          : Paradyne Corporation
Title                           : ACCULINK 3172 and 3174 E1 DSU/CSU Quick Reference - 3170-A2-GL10-20
Create Date                     : 2001:06:21 13:55:07
Page Count                      : 20
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools

Navigation menu