AirChek TOUCH Installation/Operation Caution Guide Form 38053 PDF

User Manual: 38053

Open the PDF directly: View PDF PDF.
Page Count: 1

DownloadAirChek TOUCH Installation/Operation Caution Guide Form 38053 PDF
Open PDF In BrowserView PDF
Manual Pump Reset
If the pump is not responsive, reset the pump.

AirChek TOUCH
Installation/Operation Caution Guide

1.

a. Use 2.5-mm Allen wrench to loosen 2 screws on bottom of battery housing;
pull battery pack away.
b. Align battery pack with bottom of pump case. Align connector on top of battery
pack with protruding control board contacts on bottom of pump case.

• Do not operate pump from or charge pump with charging cradle in hazardous
locations.
• Power off pump before removing battery to avoid loss of time, date, and other
settings.

c. Press two parts together until snug; use 2.5-mm Allen wrench to tighten
two screws on bottom of battery housing in an alternating fashion.
2.

• Use only the SKC-approved battery pack (Cat. No. P75718) and charging
cradle (Cat. No. 220-800 or 220-900) for pump. Use of an unapproved battery
and/or charging cradle could damage the pump and will void any warranty.
• Tampering with the battery pack (opening, disassembling, short circuiting,
crushing, or exposing the battery pack to fire or temperatures in excess of
212 F [100 C]) voids any warranty.
• User may replace external components such as the inlet filter, battery, protective
screen cover, and/or belt clip. Service must be done by SKC to maintain
performance and IS rating. Warranty is void if pumping compartment is opened
by user.

Remove battery pack, and then re-install battery pack:

Touch screen.
a. If pump is responsive, continue pump operation.
b. If pump remains unresponsive, proceed to Step 3.

3.

Remove battery pack (see Step 1.a). Lay pump case on flat surface with AirChek
TOUCH logo facing upward.

4.

Locate two protruding power control board contacts on bottom of pump case.

5.

Rest a metal paperclip across the two control board contacts labeled “RESET” for
at least eight seconds, and then remove paperclip.
Do not use a sharp object on contacts. Do not damage contacts.

• Failure to follow warnings and cautions voids any warranty.
6.
• WARNING: Substitution of components may impair intrinsic safety.
ADVERTISSEMENT: La substitution de composants peut compromettre la
Sécurité Intrinsèque.

Re-install battery pack immediately (see Steps 1.b and 1.c) and check pump
responsiveness. Note: Ensure that battery is charged at least 25% (battery status icon
on Home screen should show two bars).

• CAUTION: The battery used in this device may present a risk of fire or explosion
when heated above 212 F (100 C) or incinerated. Replace battery with SKC
Unlisted Component Battery Pack (Cat. No. P75718) only. Use of another
battery may present a risk of fire or explosion.
• Model 220-5000TC: Exia – Intrinsically safe/ Sécurité Intrinsèque
• WARNING: To prevent ignition of a hazardous atmosphere, batteries must only
be changed (removed and replaced) in an area known to be non-hazardous.
ADVERTISSEMENT: Afin de prévenir l’inflammation d’atmosphères
dangereuses, ne changer les batteries que dans des emplacements désignés
non dangereux.
• CAUTION: Risk of Fire and Burns. Do not disassemble, heat above 212 F
(100 C), or incinerate. Keep battery out of reach of children and in original
package until ready to use. Dispose of used batteries promptly according to
(all state and) local recycling or waste regulations.

SKC Inc., Eighty Four, PA

•

Tel: 724-941-9701

www.skcinc.com

•

E-mail: skcinc@skcinc.com
Form 38053 Rev 1705



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : mlf
Create Date                     : 2017:06:19 14:58:43-04:00
Keywords                        : AirChek, TOUCH, Installation/Operation, Caution, Guide, Form, 38053, PDF, Document
Modify Date                     : 2017:06:19 15:26:02-04:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Producer                        : Acrobat Distiller 10.1.16 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2017:06:19 15:26:02-04:00
Format                          : application/pdf
Title                           : AirChek TOUCH Installation/Operation Caution Guide Form 38053 PDF Document
Creator                         : mlf
Description                     : AirChek TOUCH Installation/Operation Caution Guide Form 38053 PDF Document
Subject                         : AirChek TOUCH Installation/Operation Caution Guide Form 38053 PDF Document
Document ID                     : uuid:04f6b77e-b67d-4ce6-be3d-2d75664f56d8
Instance ID                     : uuid:3776b873-1501-4b14-a4a7-0f1bb819340d
Page Count                      : 1
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools

Navigation menu