Installation Manual for the

ACCESS
SYSTEMS
PROFESSIONAL RESIDENTIAL

4000XLS

NCB

SINGLE Gate Operator System
PROFESSIONAL INSTALLATION RECOMMENDED!
WARNING!
This equipment is similar to other gate or door equipment and meets or exceeds
Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has
hazards associated with its use and therefore by installing this product the installer
and user accept full responsibility for following and noting the installation and
safety instructions. Failure to follow installation and safety instructions can result
in hazards developing due to improper assembly. You agree to properly install this
product and that if you fail to do so GTO Access Systems, (“GTO”) shall in no event
be liable for direct, indirect, incidental, special or consequential damages or loss of
profits whether based in contract tort or any other legal theory during the course
of the warranty or at any time thereafter. The installer and/or user agree to assume
responsibility for all liability and use of this product releasing GTO Access Systems,
from any and all liability. If you are not in agreement with this disclaimer or do not
feel capable of properly following all installation and safety instructions you may
return this product for full replacement value.
READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to
install and use this automatic gate operator. This gate operator produces a high level
of force. Stay clear of the unit while it is operating and exercise caution at all times.
All automatic gate operators are intended for use on vehicular gates only.

This product meets and exceeds the requirements of UL 325, the standard which
regulates gate operator safety, by Underwriters Laboratories Inc.

For more information on the Linear PRO Access full line of automatic gate operators
and access controls visit our website at www.linearproaccess.com.
©2016 GTO Access Systems, LLC

Printed in China for GTO Access Systems, LLC.

R4854 06-03-16

Class Rating
The LPA 4000XLS Gate Operator is intended for use with vehicular swing gates in single family residential
applications. The operator is system certified to be in compliance with UL 325, current edition, as of publication date.
Vehicular Gate Operator Class Categories:
Residential Vehicular Gate Operator—Class I: A vehicular gate operator (or system) intended for use in a home of
one-to-four single family dwelling, or a garage or parking area associated therewith.
Commercial/General Access Vehicular Gate Operator—Class II: A vehicular gate operator (or system) intended for
use in a commercial location or building such as a multifamily housing unit (five or more single family units), hotel,
garages, retail store, or other building servicing the general public.
Industrial/Limited Access Vehicular Gate Operator–Class III: A vehicular gate operator (or system) intended for use
in an industrial location or building such as a factory or loading dock area or other locations not intended to service
the general public.
Restricted Access Vehicular Gate Operator–Class IV: A vehicular gate operator (or system) intended for use in
a guarded industrial location or building such as an airport security area or other restricted access locations not
servicing the general public, in which unauthorized access is prevented via supervision by security personnel.

Converting Metric Units to English Equivalents
When You Know

Multiply By

To Find

Symbol

centimeters
meters
kilograms

0.3937
3.2808
2.2046

inches
feet
pounds

in. (or ")
ft. (or ')
lb. (or #)

Converting English Units to Metric Equivalents
When You Know

Multiply By

To Find

Symbol

inches
feet
pounds

2.5400
0.3048
0.4535

centimeters
meters
kilograms

cm
m
kg

deg. Fahrenheit
deg. Celsius

°F
°C

Converting Temperature

deg. Celsius
deg. Fahrenheit

(°C x 1.8) + 32
(°F-32) ÷ 1.8

FOR YOUR RECORDS
Please record the following information product serial number (located on right side of control box), be sure to
keep all receipts for proof of purchase. Refer to this information when calling Linear PRO Access for service
or assistance with your automatic gate opener.

Serial Number:____________________________________

Date of Purchase:_________________

Place of Purchase:____________________________________________________________________

Table of Contents
Class Rating.......................................................................................................................inside cover
Please Read This First...........................................................................................................................ii
Important Safety Instructions........................................................................................................ iii
Technical Specifications..................................................................................................................... 1
Before You Begin.................................................................................................................................. 2
Determine Charging Option for Battery: Transformer OR Solar.................................. 2
Solar Panel and Gate Activity Chart........................................................................................ 2
Check Direction of Gate Swing................................................................................................. 3
Prepare the Gate............................................................................................................................ 3
Gate Grounding ............................................................................................................................. 3
4000XLS Parts List.......................................................................................................................... 4
Tools Needed................................................................................................................................... 5
Materials You may Need for the Installation: ...................................................................... 5
Installation Overview................................................................................................................... 6
Install the Operator............................................................................................................................. 6
Install the Post Bracket Assembly............................................................................................ 6
Check Clearance............................................................................................................................. 8
Install Gate Bracket........................................................................................................................ 9
Attach Operator.............................................................................................................................. 9
Install Closed Position Stop Plate...........................................................................................10
Mount Battery Box and Control Box.....................................................................................11
Connect Operator Power Cable..............................................................................................12
Connect the Power Input .........................................................................................................14
Control Board Settings.....................................................................................................................16
Set the Closed Position Limit (for Pull-To-Open Applications)....................................16
Adjust the Stall Force Setting..................................................................................................17
Set Auto Close Time....................................................................................................................17
Program Your Personal Transmitter Setting.......................................................................18
Dip Switch Settings.....................................................................................................................19
Connecting Accessories...................................................................................................................20
Wiring Accessories.......................................................................................................................20
Connecting Other Auxiliary Devices (Sirens, Lights, etc.)..............................................21
Push-To-Open Installation..............................................................................................................22
Setting the Open Position Limit (Push-To-Open Installations)....................................23
Column Installation...........................................................................................................................24
Troubleshooting Guide....................................................................................................................25
Voltage Readings.........................................................................................................................26
Repair Service................................................................................................................................27
Accessories...........................................................................................................................................28

Please Read This First

Thank you for purchasing the Linear PRO Access 4000XLS. When correctly installed and properly used,
your LPA 4000XLS operator will give you many years of reliable service. Please read the following
information to ensure you have the correct system for your particular needs. This manual will enable you
to properly install your LPA 4000XLS Automatic Gate Operator.
The 4000XLS operator is designed for installation on a pull-to-open single leaf gate. The gate must not
exceed 20 feet in length nor weigh more than 1000 pounds* (please see Technical Specifications on page
1). The 4000XLS operator can be used on vinyl, aluminum, chain link, farm tube, and wrought iron gates.
Use on solid (wood) gates is not recommended. Solid surface gates have a high resistance to the wind.
If the wind is strong enough, the operator will obstruct, stop, and blow fuses.
The 4000XLS can be installed on a push-to-open gate with the addition of the push-to-open bracket
[R4KPTO].
The 4000XLS operator accommodates extra transmitters, digital keypads, solar panels, push buttons,
automatic gate locks, and other access control products. These optional accessories are noted with the
symbol.
The 4000XLS operator features adjustable stall force. This safety feature makes the gate stop and reverse
direction within two seconds when it comes in contact with an obstruction. The “MIN” setting means the
gate will exert the minimum force on an obstruction before it stops and reverses direction.
The 4000XLS operator also has an adjustable auto-close feature. It can be set to remain open from 3 to
120 seconds before automatically closing. Pressing the transmitter button at any time after the gate fully
opens will cause it to close immediately. “OFF” is the factory setting; meaning the gate will stay open until
you press the transmitter button (or keypad, etc.) again.
Please call Linear PRO Access at (800) 543-4283 for more information about our professional line of gate
operators and accessories. Our Sales Department will be glad to give you the name and phone number of
a Linear PRO Access dealer near you.
BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPERATOR:
Read these instructions carefully and completely to become familiar with all parts and installation
steps. You must read the installation manual for detailed instructions on gate operator safety
and proper use of the gate operator.

24/7 Troubleshooting Wizard: http://support.gtoinc.com

GTO Accessories are noted with this symbol in this Installation
Manual. Information about accessories can be found on page 28
and at www.linearproaccess.com.
ii LPA 4000XLS Instruction Manual

IMPORTANT SAFETY INSTRUCTIONS
Because automatic gate operators produce high levels of force, consumers need to know the potential
hazards associated with improperly designed, installed, and maintained automated gate operator
systems. Keep in mind that the gate operator is just one component of the total gate operating system.
Each component must work in unison to provide the consumer with convenience, security, and safety.
This manual contains various safety precautions and warnings for the consumer. Because there are
many possible applications of the gate operator, the safety precautions and warnings contained in
this manual cannot be completely exhaustive in nature. They do, however, provide an overview of the
safe design, installation, and use of this product. CAREFULLY READ AND FOLLOW ALL SAFETY
PRECAUTIONS, WARNINGS, AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE
SYSTEM DESIGN, INSTALLATION, AND USE OF THIS PRODUCT.
warning symbol. The symbol
Precautions and warnings in this manual are identified with this
identifies conditions that can result in damage to the operator or its components, serious injury, or
death.
Because automatic gate operators are only part of the total gate operating system, it is the
responsibility of the installer/consumer to ensure that the total system is safe for its intended
use.

How To Manually Open and Close the Gate:
CAUTION: The gate can be opened and closed manually when the operator is disconnected.
ONLY disconnect the operator when the operator power switch is OFF and the gate is NOT moving.

Disconnecting the Operator
1. Turn operator power switch (Control Box) OFF.
2. Remove hairpin clip, clevis pin, and bushing from both the front and
rear mounting points.

Front Mount

3. Remove the operator from the mount.

Clevis Pin
Gate Bracket

CAUTION: Because the LPA gate operator is battery powered,
disconnect the operator ONLY when the power switch on the contol
box is turned OFF. Unplugging the transformer does not turn power
to the operator OFF.

Bushing
Hairpin Clip

[FM345] for the clevis pin on the front
NOTE: Substitute a Pin Lock
mount of the gate operator to prevent unauthorized removal of the
operator from the gate.

LPA 4000XLS Instruction Manual

iii

IMPORTANT SAFETY INSTRUCTIONS
For The Consumer
WARNING: To reduce the risk of injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS. Failure to meet the requirements set forth in the instruction manual
could cause severe injury or death, for which the manufacturer cannot be held responsible.
2. When designing a system that will be entered from a highway or main thoroughfare, make sure the system is placed
far enough from the road to prevent traffic congestion.
3. The gate must be installed in a location that provides adequate clearance between it and adjacent structures when
opening and closing to reduce the risk of entrapment. Swinging gates must not open into public access areas.
4. The gate and gate operator installation must comply with any applicable local codes.

I. Before Installation
1. Verify this operator is proper for the type and size of gate, its frequency of use, and the proper class rating.
2. Make sure the gate has been properly installed and swings freely in both directions. Repair or replace all worn or
damaged gate hardware prior to installation. A freely moving gate will require less force to operate and will enhance
the performance of the operator and safety devices used with the system.
3. Review the operation of the system to become familiar with its safety features. Understand how to disconnect the
operator for manual gate operation (page iii).
4. This gate operator is intended for vehicular gates ONLY. A separate entrance or gate must be installed for
pedestrian use (page vi).
5. Always keep people and objects away from the gate and its area of travel. NO ONE SHOULD CROSS THE PATH
OF A MOVING GATE.
6. Pay close attention to the diagram below and be aware of these areas at all times.

ZONE 2

ZONE 1

ZONE 3

ZONE 5

ZONE 4

Driveway

Gate in the
Open Position

Entrapment Zones for a proper Pull-To-Open installation:
Zone 1 – leading edge of the gate and post.
Zone 2 – between the gate and the gate post.
Zone 3 – the path of the gate.
Zone 4 – the space between the gate in the open position and any object such as a wall, fence, etc.
Zone 5 – pinch points between the operator and gate.

iv LPA 4000XLS Instruction Manual

IMPORTANT SAFETY INSTRUCTIONS
II. During Installation
1. Install the gate operator on the inside of the property and fence line. DO NOT install an operator on the outside of
the gate where the public has access to it.
2. Be careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched.
3. Devices such as contact sensors (safety edges) and non contact sensors (photo beams) provide
additional protection against entrapment.
4. If push buttons or keypads are installed, they should be within sight of the gate, yet located at least 10 feet from any
moving part of the gate (see diagram below). Never install any control device where a user will be tempted to
reach through the gate to activate the gate operator.
5. Do not activate your gate operator unless you can see it and can determine that its area of travel is clear of people,
pets, or other obstructions. Watch the gate through its entire movement.
6. Secure outdoor or easily accessed gate operator controls in order to prohibit unauthorized use of the gate.

10'

10'

10'
Moving Gate
Area

Driveway

NEVER INSTALL
any control device
within gray area

10'

III. After Installation
1. Attach the warning signs (included) to each side of the gate to alert the public of auto­matic gate operation. It
is your responsibility to post warning signs on both sides of your gate. If any of these signs or warning decals
become damaged, illegible or missing, replace them immediately. Contact GTO for free replacements.
2. The gate is automatic and could move at any time, posing a serious risk of entrapment. No one should be in
contact with an activated gate when it is moving or stationary.
3. Do not attempt to drive into the gate area while the gate is moving; wait until the gate comes to a complete stop.
4. Do not attempt to “beat the gate” (drive through) while the gate is closing. This is extremely dangerous.
5. Do not allow children or pets near your gate. Never let children operate or play with gate controls. Keep ALL
gate controls away from children and unauthorized users; store controls where children and unauthorized users do
not have access to them.
6. KEEP GATE AND GATE Operator PROPERLY MAINTAINED. Always turn power to operator OFF before
performing any maintenance. Regularly grease the gate hinges. Apply silicone spray to a soft, dry cloth and clean
the push-pull tube at least once a month.
LPA 4000XLS Instruction Manual

v

IMPORTANT SAFETY INSTRUCTIONS
7. To operate this equipment safely, YOU must know how to disconnect the operator for manual gate operation (page
iii). If you have read the instructions and still do not understand how to disconnect the operator, contact the LPA
Service Department.
8. Disconnect the operator ONLY when the power is TURNED OFF and the gate is NOT moving.
9. Make arrangements with local fire and law enforcement for emergency access.
10. Distribute and discuss copies of the IMPORTANT SAFETY INSTRUCTIONS section of this manual with all
persons authorized to use your gate.
11. IMPORTANT: Save these safety instructions. Make sure everyone who is using or will be around the gate
and gate operator are aware of the dangers associated with automated gates. In the event you sell the
property with the gate operator or sell the gate operator, provide a copy of these safety instructions to
the new owner.
		 Should you lose or misplace this manual, a copy can be obtained by downloading one from the Linear PRO
Access web site (www.linearproaccess.com), by contacting GTO Access Systems., at 3121 Hartsfield Road,
Tallahassee, Florida 32303 or by calling 1-800-543-4283 and requesting a duplicate copy. One will be provided
to you free of charge.

Required Safety Precautions for Gates
Install Warning Signs
Warning signs alert people of automatic gate operation and are required when installing the LPAO Gate Operator. The
Warning Signs included must be installed on both sides of each gate. Furthermore, a walk-through gate must be installed
for pedestrian traffic. We recommend using the GTO Bulldog Pedestrian Gate Lock [FM145] for controlled access.

Entrapment Protection
The operator’s inherent obstruction settings, even when properly adjusted, may not be sensitive enough to prevent
bodily injury in some circumstances. For this reason, safety devices such as safety edge sensors (or photoelectric
sensors), which stop and reverse gate direction upon sensing an obstruction, are suggested for enhanced protection
against entrapment.

GTO Bulldog Pedestrian
Gate Lock
(recommended, not included)

Pedestrian Gate

Contact Sensor

(recommended, not included)

Warning Sign

Vehicular Gate

Photo Beam

(recommended, not included)

vi LPA 4000XLS Instruction Manual

Contact Sensor

Contact Sensor

Photo Beam

(recommended, not included) (recommended, not included) (recommended, not included)

IMPORTANT SAFETY INSTRUCTIONS
Secondary Means of Protection Against Entrapment

As specified by Gate Operator Safety Standard, UL 325 (30A.1.1), automatic gate operators shall have an inherent
entrapment sensing system, and shall have provisions for, or be supplied with, at least one independent secondary
means to protect against entrapment. The 4000XLS utilizes Type A, an inherent (i.e., built-in) entrapment sensing system
as the primary type of entrapment protection. Also, the 4000XLS has provisions for the connection of Type B1 or B2
protection to be used as the secondary type of entrapment protection, if desired.
1. For gate operators utilizing a non-contact sensor (e.g., photo-electric sensor– Type B1) in accordance with UL 325
(51.8.4 [h]):
A. Refer to the sensor manufacturer’s instructions on the placement of non-contact sensors for each type of
application.
B. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the
gate is still moving.
C. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the
perimeter reachable by a moving gate or barrier.
2. For gate operators utilizing a contact sensor (e.g., safety edge sensor– Type B2) in accordance with UL 325 (51.8.4
[i]):
A. One or more contact sensors shall be located at the leading edge, bottom edge, and post edge, both inside and
outside of a vehicular swing gate system.
B. A hard wired contact sensor shall be located and its wiring arranged so that the communication between the
sensor and the gate operator is not subjected to mechanical damage.
C. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for
entrapment protection functions shall be located where the transmission of the signals are not obstructed or
impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall
function under the intended end-use conditions.
You may want to consider adding photo beams to your installation. GTO Photo Beams
means of entrapment protection.

[R4222] provide a “non contact”

Leading Edge Contact Sensor
on both sides of the gate

Vehicular Gate
Photo Beam
Bottom Edge Contact Sensor
on both sides of the gate

Post Edge Contact Sensor
on both sides of the gate

Photo Beam

ENTRAPMENT ALARM (UL 325; 30A.1.1A)

The 4000XLS Gate Operator is designed to stop and reverse within 2 seconds when the gate comes in contact with
an obstruction. Additionally, these operators are equipped with an audio entrapment alarm which will activate if the
unit obstructs twice while opening or closing. This alarm will sound for a period of 5 minutes, or until the operator
receives an intended signal from a hard wired entry/exit source (e.g. push button control or keypad) and the gate
returns to a fully open or fully closed position. Turning the power switch on the control box OFF and back ON will also
deactivate the alarm. Wireless controls such as transmitters and wireless keypads will not deactivate the alarm.

LPA 4000XLS Instruction Manual

vii

IMPORTANT SAFETY INSTRUCTIONS

!

4000XLS SERIES DC Swing Gate Operator
P/N LPA-4000XLS

9901178

Conforms to UL STD 325
Certified to CSA STD C22.2 No.247
Maximum Gate: 1000 lb. (453.6 kg); 20 ft. (6.1 m)
Voltage: 12 Vdc; Frequency: 0 Hz; Power: 60 W
Class I & II Vehicular Swing Gate Operator.

Serial Number: LPA4000XLS-0000000

TO MANUALLY OPEN AND CLOSE THE GATE:
1. Turn control box power switch OFF.
2. Disconnect front or rear mount from mounting bracket.
3. Pull operator away from mounting brackets and move gate.
Disconnect operator ONLY when the control box power
switch is OFF and the gate is NOT moving.
GTO Access Systems, LLC - Tallahassee, Florida USA
MMDDYY

Warning signs (2 enclosed) to be installed on each side
of the gate (3–5 feet above the bottom of the gate).

Product identification and manual operation instruction
label (1) installed on right side of control box.

Logo and warning labels (2) installed on each side of operator housing.

viii LPA 4000XLS Instruction Manual

Technical Specifications
GTO/ACCESS SYSTEMS 4000XLS AUTOMATIC GATE OPERATOR
DRIVE

• Low friction screw drive (linear actuator) rated for -5 ºF to +160 ºF (-21 ºC to +71 ºC). Use of GTO battery heater FM316
(Not solar compatible) is recommended in extreme cold temperatures.
• Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 375 rpm.
• Maximum opening arc of 110º. Approximate opening time (90º): 16-20 seconds, depending on weight of gate.

POWER

• The system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable acid battery.
• Battery charge is maintained by a 120 Vac, 18 Vac output transformer. Blade-style control board fuse is rated for 25 A.
		 NOTE: The transformer should not be directly connected to any battery. Do not replace fuses with higher ampere rated
fuses; doing so will void your warranty and may damage your control board.
• For optional solar charging see page 2.

CONTROL

• LPA microprocessor-based control board is set for pull-to-open gate installations. DIP switches can be adjusted to
accommodate an optional kit for push-to-open gates (see Accessory Catalog).
• A circuit on the control board regulates charging. “Sleep draw” is 25 mA; “active draw” is 5 to 9 A.
• Auto-memorization of digital transmitter code.
• LPA remote-mounted RF receiver tuned to 318 MHz.
• Operator length with push-pull tube fully retracted is 46 1/4”, mounting point to mounting point, arm stroke 22” max.
• Minimum gate length is 6 ft.
• Adjustable auto-close (3 to 120 seconds), and stall force potentiometers.
• Power terminal block accommodates a transformer or solar panels (not both).
• DIP switches simplify setup of gate operator.
• Accessory terminal block fully compatible with LPA push button controls, digital keypads, loops detectors, etc.
• Control board allows connection of safety edge sensors and photoelectric sensors.
• Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.

OPERATIONAL CAPACITY
• The Gate Capacity Chart shows approximate cycles, per day, you can expect from the LPA 4000XLS Automatic
Gate Operators when powered with a transformer. Actual cycles may vary slightly depending upon the type and
condition of gate and installation.
GTO/ACCESS SYSTEMS 4000XLS Gate Capacity Chart
Gate Length

Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery

20 ft.
16 ft.
12 ft.
6 – 10 ft.

135
140
145
150
300 lb.

130
135
140
145
400 lb.

125
120
130
125
135
130
140
135
500 lb. 600 lb.
Gate Weight

115
120
125
130
700 lb.

110
115
120
125
800 lb.

105
100
110
105
115
110
120
115
900 lb. 1000 lb.

		 NOTE: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB.
		 To determine the number of cycles the gate operator will perform using solar panels, please see the specifications
listed on page 2.
		 * An operation cycle is one full opening and closing of the gate.
These specifications are subject to change without notice.

LPA 4000XLS Instruction Manual

1

Before You Begin...
1. Determine Charging Option for Battery: Transformer OR Solar
NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME.
It will damage the control board.
IMPORTANT:
• The 4000XLS’ 12 volt battery must be charged by either connecting the transformer (included) or
solar panel kit [FM123] to the control board.
• The transformer is designed for indoor use. If the transformer can be plugged only into an outside
electrical outlet, a weatherproof cover/housing (available at local electrical supply stores) must be
used.
• If your gate is more than 1000 ft. from an AC power source, you will need to use at least 10 watts
solar charging power to charge the battery [FM123]. Refer to the Solar Panel and Gate Activity
chart below.
• All low voltage wire used with the GTO Gate Operator must be 16 gauge dual conductor, stranded,
direct burial wire [RB509]. Do not run more than 1000 ft. of wire.

Solar Panel and Gate Activity Chart
The table and map
illustrate the maximum
number of gate cycles
to expect per day in a
particular area when
using from 10 to 30
watts of solar charging
power. The figures
shown are for winter
(minimum sunlight).
Accessories connected to your system
will draw additional power from the
battery.
NOTE: A minimum of 10 watts solar
charging power is needed to charge the
batteries. Adding a second battery
[RB500] will improve the number of gate
cycles.
10 Watt Solar Panel [FM123]
5 Watt Solar Panel [FM122]

2 LPA 4000XLS Instruction Manual

Winter Ratings for 12 V Single Gate
10 watts
15 watts
20 watts
25 watts
30 watts

Zone 1
8
11
14

Zone 2
16
20
28

Zone 3
26
30
38

17

36

46

20

44

54

2. Check Direction of Gate Swing
The 4000XLS is designed for PULL-TO-OPEN installations.
PUSH-TO-OPEN installations require a Push-To-Open Bracket
[R4KPTO]. Please refer to specific Push-To-Open Installation
Information on page 22.

Your Property

Pull-To-Open

3. Prepare the Gate

(arm retracts to open)

Your Property

Push-To-Open

(arm extends to open)

•
•
•
•
•

The gate must be plumb, level, and swing freely on its hinges.
The gate must move throughout its arc without binding or dragging on the ground.
Wheels must NOT be attached to the gate.
Gates over 250 lb. should have ball bearing hinges with grease fittings.
Post must be secured in the ground with concrete (minimizes twist/flex when the operator is
activated).
• Make sure there is a stable area for mounting the gate bracket (this may require the addition of a
horizontal or vertical cross member).
• We recommend you position the operator near the center-line of the gate to keep the gate from
twisting and flexing, and to avoid back-splash from rain.
Horizontal Cross Member

A
E

F

B
Vertical Cross Member

C
A – Level
B – Plumb
C – Free Swinging

D – Posts Secured in Concrete
E – Centerline Mounting
F – Good Working Hinges

D

4. Gate Grounding
• Shorter cable is better, 1 to 2 feet
recommended.
• Bolt ring terminal at end of cable
4 - 6 inches above ground level.

Metal Gate
Post

Ground Rod
Clamp
6 AWG Wire

R4196 Kit Includes:
u Ground Rod Clamp
v 6 AWG Wire (3 feet)
NOTE: No grounding system
absolutely protects against
lightning strikes. If installed
correctly, a grounding system will
help minimize damage to your
gate opener.

8 Foot Ground Rod
5/8” Copper Clad Steel (not included)
- available at local homecenter and hardware stores -

LPA 4000XLS Instruction Manual

3

4. 4000XLS Parts List

®

R

ENE
TE OP
E-Z GA

Customer Support Card (1)
Master Operator Arm (1)
LPA 4000XLS Arm

6’ Power Cable

BRACKET BOX - HB4000

Closed Position
Stop Plate (1)

Gate Bracket (1)

Post Bracket (1)

Post Pivot Bracket (1)

HARDWARE BAG - H401P

1/2" x 10" Bolt (2)

8" Nylon Cable Tie (10)

1/2" x 2-3/4" Bolt (2)
1/2" Lock Nut (4)
3/8" x 3-3/4" Bolt (2)
3/8" Washer (3)
3/8" x 3-1/2" Clevis Pin (1)
3/8" Lock Nut (2)
3/8" x 1-3/4" Clevis Pin (1)

Hairpin Clip (2)

4 LPA 4000XLS Instruction Manual

3/8" x 1/2" Bushing (2 )

3/8" x 3/16" Bushing (2)

2" Receiver Mounting Screws (5)

1/2" Washer (4)

Battery (1)

! WARNING
Receiver (1)
GTO Transmitter(1)

Moving Gate Can Cause
Injury Or Death
1.

KEEP CLEAR! Gate may move at any time.

2.

Do not allow children to operate gate or
play in gate area.

3.

This gate is for vehicles only. Pedestrians
must use a separate entrance.

Warning Signs (2)
Control Box (1)

Transformer (1)

Drill

Drill Bit

5. Tools Needed

Center
Punch

Pen

Pliers

Hack Saw
Hammer

Open End Wrenches

Flat Head
Screwdriver

Phillips Head
Screwdriver

Level
Clamps

Small, Medium, Large

Adjustable
Wrench

Wire
Stripper

Small
Flat Head

Tape
Measure

• Power Drill
• Pliers
• Level
• Tape Measure
• Wire Strippers • Center Punch
• Open End Wrenches: 9/16” and 3/4”
• Drill Bit: 1/2”
• Hacksaw or Heavy Duty Bolt Cutters
• Small (Flat Head) Screwdriver
• Phillips Screwdriver
• C-Clamps: small, medium, and large
• Adjustable Wrench
• Extra person will be helpful

6. Materials You may Need for the Installation:
Depending on the type of gate and post, you may need some additional materials/hardware.
• Low voltage wire [RB509]. Length depends upon the distance between the transformer power
supply and the control box. (Page 13)
• If the gate is more than 1000’ away from an AC power source you will need to use at least one 10
watt Solar Panel [FM123] to trickle charge the battery. (Page 2)
• PVC Conduit. (Page 6)
• The diameter of the post should be at least 6” in order to mount the post bracket. (Page 6)
• Depending upon the diameter of the post, you may need longer bolts than those provided. Bolts
should be at least 1” longer than the diameter of the post. (Page 6)
• Metal plate for wooden posts. (Page 6)
• A horizontal or vertical cross member or mounting plate may be needed to mount the operator to
the gate. (Page 3)
• Some types of installations require U-Bolts. (Page 10)
• Surge protection for transformer. (Page 15)
• Weatherproof cover for transformer if installed outside. (Page 15)
• For push-to-open applications you must have PTO Bracket [R4KPTO). (Page 22).

LPA 4000XLS Instruction Manual

5

7. Installation Overview
Pull-To-Open Gates (Gate Opens into the Property)
The diagram shown below is an example of a Pull-To-Open installation on a chain link fence and single
gate. Mounting the operator on a masonry column requires special procedures; see Column Installation
Information on page 24. Furthermore, if you have a Push-To-Open gate, see Push-To-Open Installation on
page 22 before proceeding.
Receiver

Control Box with Battery

Gate Swings Evenly and Freely
Hung Firmly and Plumb

Horizontal Cross Member

Post Bracket Assembly
Single Gate Opener

120 Volt indoor
Transformer
(surge protector
not supplied)

Gate Bracket

Warning Sign
Power Cable

Closed Position Stop Plate

Run 1000' (max.) of low
voltage wire to control
box from transformer
(wire not included).

Fence Post Set in Concrete
PVC conduit (not included)
to protect wire from lawn
mowers and weed eaters.

Install the Operator
Install the Post Bracket Assembly
The post bracket is designed to work on a flat post. Posts
must be at least 6” square in order to bolt the post bracket.
When using bolts to mount the post bracket, the bolts must
completely penetrate the post.
• The best method of attaching the post bracket to a metal
post is welding.
• If your post exceeds 8”, it will be necessary to use hex
head bolts longer than those supplied.
• Round wood posts (no smaller than 8” diameter) may be
notched to create a flat surface for attaching the post
bracket.
• Wood posts will require a metal plate (not provided)
between the nuts and post to prevent the operator from
pulling the bolts and washers through the wood.
• A post smaller than 6” in diameter should be made of
metal instead of wood so that it will remain stable while
the operator is moving the gate.
• Masonry columns will require masonry anchors/
hardware (not provided).
6 LPA 4000XLS Instruction Manual

Step 1

Close the gate and place your level
against the horizontal cross member.
Position the level so that the top should
be in the center of the cross member
and overlaps the post. Scribe a line
across the cross member and post.
You will use this line to help determine
position of post and gate brackets.

Step 2
Position the post bracket on the post with the mounting holes
centered over the scribe line. The post bracket should be
flush with the edge of the post closest to the gate. Mark the
position of post bracket holes on the post.

Step 3
Drill holes through post as marked using a 1/2” drill bit. Install
the post bracket using the 1/2” x 10” carriage bolts, 1/2” flat
washers and lock nuts (provided)­.

Carriage Bolts

Metal reinforcement plate
for wood post

3/8" x 3-3/4" Bolt
3/8" Washer
Post Bracket

Step 4
Place the end of post pivot bracket with two holes inside the
post bracket. Align the back hole in the post pivot bracket
with back hole in the post bracket.­Insert 3/8” x 3 3/4” hex head
bolt and washer through post pivot bracket and post bracket
and secure with 3/8” washer, and lock nut.

3/8" Washer
3/8" Lock Nut

Post Pivot Bracket

LPA 4000XLS Instruction Manual

7

Step 5
Position the operator rear mount between post pivot bracket.
Place a 1/2” bushing above the rear mount and a 3/16” bushing
under the rear mount. Align the hole in rear mount, bushings
and post pivot bracket and secure with the 3 1/2” clevis pin
and hair pin clip.

3/8” x 3-1/2” Clevis Pin

3/8” x 1/2” Delrin Bushing

Operator
Hairpin Clip

3/8” x 1-3/4” Clevis Pin

3/8” x 3/16” Delrin Bushing
under rear mount

Front Mount
Gate Bracket

3/8” x 3/16” Delrin Bushing
under front mount

Step 6
Hairpin Clip

Place a 3/16” bushing under the front mount and attach the
gate bracket to the front mount using the 1 3/4” clevis pin and
hairpin clip.

Check Clearance
Step 7
Open the gate to the desired open position. Position the
operator so that the gate bracket rests against the gate along
the level scribed line. Check the clearance between the
operator and the gate. The operator should only make contact
with the gate at the gate bracket. There should be a minimum
clearance of 2” between the widest part of the operator arm
and the gate.
When you have achieved the best position for the post pivot
bracket in the open position, insert the 3/8” x 3 3/4” bolt and
3/8” flat washer through the aligned holes of the post bracket
and post pivot bracket to hold it in place.
Clamp the gate bracket to the gate using c-clamps or another
type of clamp.
IMPORTANT: While determining the position of the post
pivot bracket, be sure that the position allows for minimum
2“ of clearance between the gate and the operator in both
the open and closed positions. This clearance will give the
operator the most efficient leverage point for opening and
closing the gate and, more importantly, provides the least
possible pinch area.

8 LPA 4000XLS Instruction Manual

Pinch Area

Gate in the
OPEN POSITION
2" minimum

Clamp

Step 8
Remove the clevis pin from the front
mount and while supporting the gate
operator, swing the gate and gate
operator to the closed position. With
the gate and gate operator in the closed
position check the clearance and be sure
Gate in the
Clamp
2" minimum
CLOSED POSITION
that the gate operator is not binding at
Pinch Area
the post pivot bracket.
If you don’t have 2” clearance or the
gate operator is binding on the post
MAX 22"
pivot bracket, remove the bolt in the
post bracket and readjust the pivot
bracket until you can achieve the proper
clearance.
With the post pivot bracket in the optimum position for clearance and freedom of movement, replace the
bolt in a post bracket adjustment hole and secure with washer and lock nut. Return the operator to the
open position and reattach the gate bracket. Recheck the gate operator level and clearance in the open
position. Adjustment of the gate bracket will be necessary if the post bracket was moved. After verifying
clearance, make sure the gate bracket is clamped securely.
LEVEL

Install Gate Bracket

horizon

tal cros

s mem

ber

Step 9
Detach the front mount from the gate
bracket. Check that the gate bracket
holes are centered over the scribe
line. Mark the gate in the center of the
gate bracket holes. Remove the gate
bracket and drill the 1/2” holes through
the gate cross member and attach the
gate bracket using the 1/2” x 2 3/4” bolts,
washers and lock nuts.

Mark cross member through middle of
gate bracket slots and drill 1/2" holes

FRONT VIEW

FRONT VIEW

SIDE VIEW

SIDE VIEW

Round Tube & Chain Link Gate

Attach Operator

(required but not supplied)

Step 10

Make sure the gate is in the open
position and the operator arm is fully
retracted. Attach the operator to the
securely bolted post bracket assembly
and gate bracket using clevis pins,
bushings, and hairpin clips, or optional
Pin Lock [FM345]. Verify that the
operator is level, bolts are tight, and
adjust the post bracket assembly if
necessary.

Mounting Plate Created
for Decorative Gate

Square Tube Gate

Gate In Open Position

Level O

perato

r

Clevis Pin, Bushing, and Hairpin Clip
Fence Post

LPA 4000XLS Instruction Manual

9

Install Closed Position Stop Plate
The closed position stop plate helps
to stabilize the gate leaf in the closed
position. To further enhance the stability
and security of your gate, install the
optional GTO Automatic Gate Lock
[FM144]

Gate Hinge

Closed Position
Stop Plate

Step 11
Remove hairpin, clevis pin, and 3/16”
bushing from front mount and close the
gate. Fasten the closed position stop
plate to the end of the gate frame on the
gate center-line (in line with the operator
arm), but do not tighten it completely.
Slide the closed position stop plate
toward the post until they touch. Once
you have moved the closed position stop
plate to the correct position, tighten its
hardware completely.
Use the appropriate hardware for
your type of gate (U-bolts for tube or
chain link gate; wood or lag screws for
wood gates, etc.). This hardware is not
provided.

The gate must open
110º (max.)

FRONT VIEW

Closed Position Stop Plate mounted
on metal post with U-bolts.
Fence Post

Gate Post

TOP VIEW

Step 12
Return gate to the open position and reattach operator to gate.

CL
Closed Position Stop Plate

Gate In Closed Position

10 LPA 4000XLS Instruction Manual

Mount the Battery Box and Control Box
Step 1
Remove the Control box from the Battery Box by
removing four screws as shown in Illustration A.

Step 2
Mount the Battery Box using the screws (provided)
or another secure mounting method as shown in
Illustration B.
The battery/control box must be mounted at least 3
feet above the ground to protect it from rain splash,
snow, etc., and at least 3 feet from an AC power
source to prevent electrical interference.

Illustration A

Step 3
Slide the battery into position with the terminals to the right as shown in Illustration C.
Illustration B

Illustration C

Illustration D

ON/O

FF

Connecting the Battery
Step 4
Verify that the ON/OFF switch on the Control
Box is in the OFF position. Illustration D.
Connect the BATTERY WIRE HARNESS wires to
the battery --- RED wires to POSITIVE (+) battery
terminal and BLACK wires to NEGATIVE (–)
battery terminal.
The BATTERY WIRES from the CONTROL BOARD
should extend through the KNOCK-OUT in the
back of the CONTROL BOX. Plug the BATTERY
HARNESS wires into the wires coming from the
CONTROL BOX.

Red to Positive (+)
Black to Negative (–)

Connectors for
second battery.

LPA 4000XLS Instruction Manual

11

Step 5
Tuck the excess battery leads into the battery box and
reattach the CONTROL BOX to the BATTERY BOX.

Mounting the Receiver
Step 1
Temporarily mount the receiver at this time. You will need to use the transmitter (page 18) to check
the range of the receiver before permanently mounting it. You may have to try different locations before
permanently mounting the receiver. The receiver range can vary from 50 to 100 feet depending upon
weather, topography, and external interference.
Mount the receiver:
• Ensuring a line-of-sight between transmitter and
antenna.
• At least 3 feet away from AC voltage.
• As high as possible for optimum range.
Receiver mounted
on piece of wood
• DO NOT mount receiver upside down.
• DO NOT mount receiver on metal fence or post (this will
decrease signal range). If attaching receiver to metal
fence, you should mount receiver on a piece of wood
attached to the fence (see illustration).
The receiver cable:
• Cable length is 10 ft. (receivers with longer cables are
available as special order items; call the GTO Sales
Department).
• NEVER splice receiver cable!
• Run the receiver cable through PVC conduit to protect it
from damage.
• DO NOT run cable in conduit containing AC wiring.
This device complies with FCC rules Part 15. Operation is subject to the following conditions:
1. This device may not cause harmful interference.
2. This device must accept an interference that may cause undesired operation.
		 Transmitter distance may vary due to circumstances beyond our control. NOTE: The manufacturer is not
responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such
modifications could void the user’s authority to operate the equipment.

12 LPA 4000XLS Instruction Manual

Connect Operator Power Cable
Step 1

Strain Relief

Loosen sealing nut on strain relief hub at bottom
of control box. Insert power cable into control box
through strain relief. Thread approximately 6” of
the power cable into the control box and re-tighten
sealing nut until the power cable locks into place.

Lock Nut
Strain Relief

Hub
Sealing Nut

Operator
Power Cable

Step 2
GRN
WHT
BLU
BRN
ORG
RED
BLK

COM
COM
CYCLE
SAFETY
EXIT
SHADOW

BLK
RED

RECEIVER

Screwed into
wire insulation

Wrong

GTO RCVR.

Wire

Wrong

GRN

CONTROL INPUTS

Power Cable from the
Master Operator Arm

CLOSE
EDGE
OPEN
EDGE

Correct

MASTER OPERATOR

Insert the stripped power cable wires
into the appropriate terminals on the
MASTER OPERATOR terminal block.
Insert the green wire into the GRN
terminal, white wire into WHT, blue wire
into BLUE, brown wire into BRN, orange
wire into ORG, red wire into RED, black
wire into the BLK.
Tighten the set screws against the end of
the wires.
NEVER SPLICE WIRES.
Splicing permits corrosion and
seriously degrades the wire’s ability
to carry an adequate current.

Exposed strands
of wire

LPA 4000XLS Instruction Manual

13

Connect the Power Input
IMPORTANT:
• The transformer is designed and intended for indoor use. If the transformer can only be
plugged only an outside electrical outlet, a weatherproof cover/housing (available at local
electrical supply stores) must be used.
• The only wire acceptable for use with GTO products is 16 gauge stranded, low voltage, direct
burial wire [RB509]. This gauge enables the transformer to provide an adequate charge
through the control board to the battery at distances up to 1000 ft.
• DO NOT use telephone wire or solid wire.
• NEVER SPLICE WIRES. Splicing permits corrosion and seriously degrades the wire’s ability to
carry an adequate current.
• NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME! Doing so will
damage the control board.
• If your gate is more than 1000 ft. from an AC power source, you will need to use at least 10
watts solar charging power [FM122/FM123] to charge the battery. Refer to the Solar Panels
and Gate Activity Chart on page 2.

Step 1
Make sure the control box power switch is OFF.
ON/O

FF

Step 2
Select the electrical outlet into which you will plug the transformer. Measure the distance from this outlet
to the control box following the path where the wire will be laid (allow for an additional 6” to be pulled
into the control box).

Step 3
Lay the low voltage wire in a trench following a path
from the selected electrical outlet to the control box.
Wires coming up from the ground should be run through
PVC conduit to protect them from lawn mower blades,
weed eaters, and grazing animals. Bury the wire in the
trench.

Step 4
Feed the low voltage wires upward through the strain
relief opening on the lower left of the control box. Pull 6”
to 8” of wire into the control box.

Power Cable from
Master Arm
Low Voltage Wire
from Transformer

14 LPA 4000XLS Instruction Manual

PVC Pipe

RED
BLACK

AUX
RLY

CONTROL OUTPUTS

PWR

LOCK

Low Voltage Wire
from AC Transformer
or Solar Panel

POWER
INPUT

GRN
WHT
BLU
BRN
ORG
RED

2ND OPERATOR

Strip the ends of the low voltage wire and
twist tightly. Attach these ends to the 18
VAC OR SOLAR terminals located on the
POWER INPUTS terminal block. Be certain
not to let the exposed wires touch each
other!
Insert one transformer wire into an 18
VAC OR SOLAR terminal. Insert the other
transformer wire into the remaining 18 VAC
OR SOLAR terminal. The transformer wires
can be connected to the 18 VAC OR SOLAR
terminals regardless of color/polarity.
Tighten set screws against exposed end of
wires.

GTO 18VOLT
TRANSF. OR
SOLAR PANEL

Step 5

BLK

GRN

BLU
BRN
ORG
RED

MASTER OPERATOR

WHT

BLK

Step 6
At the transformer, strip 1/2” of insulation from the ends of the
low voltage wire. Attach wires to the transformer terminals.
Make sure the exposed wires do not touch each other.

Step 7
Plug the transformer into the electrical outlet. (Use
of a surge protector with the transformer is strongly
recommended.) IMPORTANT: This is a class II indoor
transformer; if using transformer outdoors be sure to
enclose it in a weatherproof case.

LPA 4000XLS Instruction Manual

15

Control Board Settings
Set Closed Position Limit (for Pull-To-Open Applications)
Step 1
Power switch is on, gate
is in the OPEN position,
operator arm
fully retracted.

ON/O

Control
Box

Gate in
OPEN
Position

FF

Step 2
Press the transmitter to
activate operator arm.
The gate will begin
toAUTO
CLOSE.
CLOSE TIME STALL FORCE

Gate
Closing
Control
Box

STATUS
LEARN RMT
120

MIN

MAX

When the gate reaches
the desired CLOSED
position, press
the transmitter
to stop the gate.

OPEN the PULL
With
gate at
SLV OPEN DLY.
the
correct
position, ON
MODE1
OFF
program
the
MODE2
OFF closed ON
limit setting by
pressing and holding
LEARN MAST LIMIT.

WARNING

Control
Box

Step 5
Press the transmitter
again to allow the gate
to return to
the fully OPEN
position.

16 LPA 4000XLS Instruction Manual

Control
Box

Gate
Closed

Gate in
OPEN
Position

OFF

ON DIP

SOFT START
Step
4 OFF

1 2 3 4

Step 3

ON
ON
PUSH
SIMULT.

S3
LEARN
MAST LIMIT
S2
LEARN
2ND LIMIT
S4

Learn Master
Limit Button

The gate closed position is now programmed.
If you make a mistake and set the limit at the
wrong position: press your transmitter to return
the gate to the fully opened position, then press
and hold the LEARN MAST LIMIT button for 5
seconds. This will clear the memory for the closed
limit position. Repeat Steps 1-5.

Adjust the Stall Force Setting

AUTO CLOSE TIME

STALL FORCE

OFF

MAX

MODE1
MODE2

OFF
OFF
PULL
DLY.

MIN

MAX

ON DIP

MIN

120

SOFT START
WARNING
OPEN
2ND OPEN

STALL FORCE

1 2 3 4

The Stall Force potentiometer on the
control board controls the obstruction
sensitivity (or the amount of force the
operator will apply to an obstruction for
two (2) seconds before it automatically
stops and reverses direction).
IMPORTANT: For safety reasons
the stall force setting will need
to be adjusted for your particular
application.
The Stall Force potentiometer on the
control board operates like a volume
control on a radio. Use a small flat blade
screwdriver to adjust the potentiometer.
Adjust the stall force from the MIN
position until the gate operates
smoothly without obstructing from its
own weight or wind conditions.
NOTE: you may need to increase the
stall force in cold temperatures due to
increased resistance from gate hinges.

OFF
OFF

ON
ON
PUSH
SIMULT.
ON
ON

Set Auto Close Time
The Auto-Close Time potentiometer controls the Auto-Close feature, and determines how long the gate
will remain open (at the fully open position) before it begins to close. The settings for this feature are OFF,
or from 3 to 120 seconds.
Adjust the Auto-Close potentiometer by using a small flat blade screwdriver.

AUTO CLOSE TIME

STALL FORCE
STATUS
LEARN RMT

OFF

MODE1
MODE2

OFF
OFF

MAX

ON DIP

Auto Close Time
Potentiometer

OFF
OFF
PULL
DLY.

MIN

1 2 3 4

SOFT START
WARNING
OPEN
2ND OPEN

120

ON
ON
PUSH
SIMULT.
ON
ON

S3
LEARN
MAST LIMIT
S2
LEARN
2ND LIMIT
S4

LPA 4000XLS Instruction Manual

17

Program Your Personal Transmitter
Setting
All GTO transmitters are set to a standard code at the
factory and are ready to operate your GTO gate operator.
For your safety and security, we strongly recommend that
you replace the factory setting with your own personal
setting. Follow the directions below:
NOTE: If you have multiple transmitters, you should adjust
all of them at this time.
[RB741/RB742/RB743].

LE

D

–

Step 1

0

+

1

2

3

4

5

A
A 2

6

3S

LK
AL
IN
E

Use a small phillips head screw driver to remove the
transmitter cover.

BA 12
TT

ER

7

8

9

EC

E

V

Y

Step 2
Set the transmitter DIP switches using a small screwdriver.
There are nine (9) switches; each can be placed in three
different positions (+, 0, –). DO NOT set all the switches
in the same position, such as all +, all 0, or all –. Once the
DIP switches have been reset, replace and close the access
cover.
WARNING: No other adjustments should be made inside the
transmitter.

1 2 3 4 5 6 7 8 9

+
0

ECE

Step 3
AUTO CLOSE TIME

STALL FORCE
STATUS
LEARN RMT

120

MODE1
MODE2

OFF
OFF
PULL
DLY.
OFF
OFF

MAX

ON DIP

SOFT START
WARNING
OPEN
SLV OPEN

MIN

1 2 3 4

Program the new setting into the control board:
A. Press and hold transmitter button.
B. Press and hold the LEARN RMT (Learn Remote) 		
		 button on the control board until the alarm sounds.
C. Release transmitter button. The new code is stored
		 in control board memory.
D. Release the LEARN RMT (Learn Remote) button.
NOTE: If you have purchased additional transmitters,
program the settings for all at this time.

ON
ON
PUSH
SIMULT.
ON
ON

S3
LEARN
MAST LIMIT
S2
LEARN
2ND LIMIT
S4

Step 4
AT THIS POINT YOU SHOULD TEST RECEIVER RANGE
BEFORE PERMANENTLY INSTALLING IT.

The Troubleshooting Wizard has
detailed information this and other
Installations.
24/7 Troubleshooting Wizard: http://
support.gtoinc.com
18 LPA 4000XLS Instruction Manual

Learn Remote
Button

DIP Switch Settings
DIP Switches
ON
DIP

1 2 3 4

ON

OFF

AUTO CLOSE TIME

STALL FORCE
STATUS
LEARN RMT

OFF

OFF
OFF
PULL
DLY.
OFF
OFF

MIN

MAX

ON DIP

SOFT START
WARNING
OPEN
2ND OPEN
MODE1
MODE2

120

1 2 3 4

DIP Switch Settings (MODES)
DIP Switch #1: Soft Start/Stop
		 ON– Soft start enabled (factory
preset).
		 OFF– Soft start disabled.
		 The Soft Start/Stop feature slowly
starts the gate as it begins to open
and slows the gate as it comes
to the closed position. This saves
wear and tear on the gate and gate
operator system.
DIP Switch #2: Warning Buzzer
		 ON– Buzzer warning enabled
(factory preset).
		 OFF– Buzzer warning disabled.
		 The Warning Buzzer alerts
you when the gate operator is
beginning to either open or close
the gate. It sounds for the first 2
seconds in each direction. It also
sounds a warning when the gate
obstructs two times in one cycle.
Switching this to OFF only disables
the open and close warning not
the obstruction warning.
DIP Switch #3: Push/Pull-To-Open
		 ON: Push-To-Open.
		 OFF: Pull-To-Open (factory preset).
		 If your gate opens into the
property the DIP Switch is set to
the OFF position (factory setting).
If your gate opens out from the
property the DIP Switch must be
set to the ON position. NOTE: if
you have a Push-to-Open gate
application you will need a PushTo-Open bracket (see Push-ToOpen Instructions on page 22).
DIP Switch #4: Dual Operation
		 ON– Second opens simultaneously
with master.
		 OFF– Second opens after master
(factory preset).
		 Note: Not applicable for single gate
operator.

ON
ON
PUSH
SIMULT.
ON
ON

S3
LEARN
MAST LIMIT
S2
LEARN
2ND LIMIT
S4

LPA 4000XLS Instruction Manual

19

Connecting Accessories
Input Connections

• All control inputs are dry-contact, normally open, inputs. DO NOT apply external voltage sources to
these inputs.
• All inputs are connected with respect to COMMON terminal.
• The status LED will blink once when its corresponding input is activated.

CONTROL INPUTS

1 COM: Circuit common (reference for
all logic input)
BLK
• Two (2) terminals to provide extra
common connection point.
2 CYCLE/CLOSE: (Typically for use
COM
1
with push button or hard-wired
COM
keypad)
• Each activation at this input will
CYCLE
2
cycle the operation as follows:
		OPEN–STOP–CLOSE–STOP–OPEN
SAFETY
3
3 SAFETY: (Typically for use with
EXIT
4
photo beam device, loop detector
or other non-contact sensors)
SHADOW
5
• Activation of this input while the
CLOSE
gate is closing will cause the gate
6
EDGE
to stop and return to the opened
OPEN
7
EDGE
position.
• Activation of this input while the
GRN
gate is opening has no effect (gate
will continue to open).
BLK
• Activation of this input while
RED
gate is idle will prevent gate from
closing.
4 EXIT/OPEN: (Typically for use with
exit loop or wand)
• Activation of this input will open
the gate if it’s not already at the open position
• Activation of this input while at open limit will restart the auto close time (if enabled).
• Activation of this input while gate at the fully open position will prevent gate from closing.
5 SHADOW LOOP: (Typically for use with loop detector)
• This input is only monitored when the gate is at the fully open position. At any other position,
activation of this input has no effect on gate operation.
• Activation of this input while gate at the fully open position will prevent gate from closing.
6 CLOSE EDGE: (Typically for use with safety edge device)
• Activation of this input while the gate is closing will cause the gate to stop and reverse direction for
approximately 2 seconds.
• Activation of this input while the gate is opening has no effect (gate will continue to open).
• Activation of this input while gate is idle will prevent gate from closing.
7 OPEN EDGE: (Typically for use with safety edge device)
• Activation of this input while the gate is opening will cause the gate to stop and reverse direction for
approximately 2 seconds.
• Activation of this input while the gate is closing has no effect (gate will continue to close).
• Activation of this input while gate is idle will prevent gate from opening.
RECEIVER

GTO RCVR.

ALM

20 LPA 4000XLS Instruction Manual

Wiring Accessories
CONTROL OUTPUTS

6

7

GTO RCVR.

6
7

Automatic Gate Lock (FM144 & FM142)

COM

ALM
RED

5

COM

4

GRN

3

BLK
BLK

2

BRN
CLOSE
EDGE
ORG
OPEN
EDGE
RED

71

BLU

6

SHADOW

5

WHT
EXIT

4

GRN
SAFETY

3

CYCLE

2

RED
COM
BLK
COM

WHT

BLU
GRN

1

7

CONTROL INPUTS

CONTROL
INPUTS
MASTER
OPERATORRECEIVER

CYCLE

AUX
2ND OPERATOR
RLYMASTER OPERATOR

GRN

BRN

GTO 18 VOLT
TRANSF. OR
SOLAR PANEL

PWR

BLK

6

RED

5

ORG

4

BLU

3

WHT

2

LOCK

BRN
WHT
ORG
BLU
RED
BRN
BLK
ORG

POWER
INPUT
2ND OPERATOR

According to
Application

1

Edge Sensor

1
2

Push Button Control (RB101)

3
1

Photo Beams (R4222)

4
1
1
4

GHI

7

PRS

2

ABC

5

JKL

8

TUV

0

Vehicle Sensor (FM139)

3

DEF

6

MNO

9

WXY

1
2

Digital Keypad (F310)

Refer to Vehicle Sensor
manual for additional
connections.

NOTE: There may be additional connection options for
applications that are not illustrated here.
Refer to accessory manuals for details.

Connecting Other Auxiliary Devices (Sirens, Lights, etc.)

AUX
RLY

• These 2 terminals are normally open “dry-contact” (no voltage) relay output.
• Relay is closed when the gate is in motion; Relay is open when the gate is not in motion.
• These 2 terminals maximum rating is 24Vdc, 1 Amp.

LPA 4000XLS Instruction Manual

21

Push-To-Open Installation Information
Swinging gates shall not open into public access areas!
A “Push-to-Open” gate opens out from the property (operator arm extends to open the gate). A Push-ToOpen installation requires the purchase of a Push-To-Open Bracket [R4KPTO].
In a Push-To-Open installation the operator is installed while the gate is in the CLOSED POSITION.

Install the Operator
Follow directions for installing the
4000XLS beginning on page 7. The PushTo-Open installation differs from the
Pull-To-Open installation in the following
ways:

Gate In Closed Position

1. In a Push-To-Open installation, the arm
fully extends to open the gate, and it
fully retracts to close the gate. (C)

Level O

A

perato

2. You will install the operator while the
gate is in the CLOSED POSITION (arm
fully retracted). (A)

r

Clevis Pin, Bushing, and Hairpin Clip
Fence Post

3. You must use the Push-to-Open Post
[R4KPTO] in the Post Bracket assembly. (B)
Pivot Bracket
4. IMPORTANT: While determining the mounting point for the
post pivot bracket assembly be sure that the position allows
for 2” clearance between the gate and the operator in both the
open and closed positions (see diagram below). This clearance
will give the operator the most efficient leverage point for
opening and closing the gate and more importantly provides
the least possible pinch area. (C)

C

Clamp

3/8" x 3-3/4" Bolt

B

3/8" Washer
Post Bracket

3/8" Washer
3/8" Lock Nut
Push-To-Open
Post Pivot Bracket
(R4KPTO)

MAX
22"

*The Troubleshooting Wizard
has detailed information on
Push-To-Open installations.

Gate in the Open Position
Pinch Area

2" minimum

Gate in the Closed Position
Pinch Area

2" minimum

22 LPA 4000XLS Instruction Manual

Clamp

2

3

4

OFF

ON
ON

MAX

OFF
OFF

MIN
120

1 2 3 4

MODE1
MODE2

1

ON DIP

OFF

ON

AUTO CLOSE TIME

ON

SOFT START OFF
WARNING
OFF
OPEN
PULL
SLV
2ND OPEN
OPEN DLY.
DLY.

STALL FORCE

Make sure the control box power switch is OFF. Use a small
screwdriver to move the Number 3 DIP switch from the
factory setting (OFF / Pull-To-Open) to ON for Push-To-Open.
Turn power switch ON. The control board is now configured
to push the gate open.

ON
ON
PUSH
SIMULT.

Set Control Board for Push-To-Open

DIP#3
ON: Push-to-open operation.
OFF: Pull-to-open operation (factory setting).

Setting the Open Position Limit (Push-To-Open Installations)
Step 1
Power switch is on, gate is
in the CLOSED position,
operator arm fully
retracted.
ON/O

Step 2

Gate in Closed
Postion

FF

Press the transmitter to
activate operator arm. The
gate will begin to OPEN.
Control
Box

AUTO CLOSE TIME

Control
Box

STALL FORCE
STATUS

Gate
Opening

LEARN RMT
120

MIN

MAX

When the gate reaches
the desired OPEN
position, press the
transmitter to
stop the gate.

OPEN the PULL
With
master
SLV OPEN DLY.
gate
at
the
correct ON
MODE1
OFF
position,
program
theON
MODE2
OFF
open limit setting by
pressing and holding
LEARN MAST LIMIT.

Step 5
Press the transmitter
again to allow the gate
to return to the fully
CLOSED position.
Gate is now
programmed

WARNING

Gate
Opened

Control
Box

Gate in Closed
Postion
Gate open position
is now programmed

Control
Box

OFF

ON DIP

SOFT START
Step
4 OFF

1 2 3 4

Step 3

ON
ON
PUSH
SIMULT.

S3
LEARN
MAST LIMIT
S2
LEARN
2ND LIMIT
S4

Learn Master
Limit Button

The gate open position is now programmed.
If you make a mistake and set the limit at the
wrong position: press your transmitter to return
the gate to the fully closed position, then press
and hold the LEARN MAST LIMIT button for 5
seconds. This will clear the memory for the open
limit position. Repeat Steps 1-5.

LPA 4000XLS Instruction Manual

23

Column Installation
If this operator will be used with gates that are mounted on masonry, brick, or rock (etc.) columns, read
the following carefully before proceeding
A.		 The simplest solution is to install the operator in a push-to-open configuration. The minimum
clearance is easier to achieve and clearance is no longer a problem, since the operator will be
pushing the gate away from the column instead of pulling it toward the column. It is recommended
that you place a steel plate between the operator mounting brackets and masonry surface for
additional strength.
B.		 If a push-to-open installation is impossible due to traffic hazards, terrain, etc., another option is to rehang the gate. You may hang it on a post, either in the center of the column or at the back corner, or
move the gate to the back corner of the column.
C.		 The most difficult solution is to cut a notch in the column to accommodate the operator and power
cable. This job is NOT for the inexperienced!*

With Pivot Bracket

Hinge

Gate
Column

Column Mount Example
(A + B can not exceed 16 inches)
Example: If A is 7" then B cannot exceed 9"

B

Pivot Bracket
A

Pivot bracket may need to be removed to achieve proper stroke and clearance requirements.
Hinge

Without Pivot Bracket
Gate

Column
Post Bracket

B

Column Mount Example
(A + B can not exceed 16 inches)
Example: If A is 7" then B cannot exceed 9"

A

*The Troubleshooting Wizard has detailed information
on column mounting.

24 LPA 4000XLS Instruction Manual

Troubleshooting Guide
If your gate operator does not function properly after it is installed, use this guide before calling the GTO
Service Department.

Generation 3 Audible Feedback
SYMPTOM
1 short beep upon
power up

DIAGNOSIS
Circuit Board
Powered Up &
Ready

CHECK:

1 short beep upon
activation

• Fuse
• Battery Under Load
• Battery Harness Connections

Continuous
Uninterrupted
Alarm

Blown Fuse
Low or Bad Battery
Loose Battery
Connection
Circuit Board
Senses an
Obstruction

1 beep with 10
seconds off

Low Battery
Condition

• Fuses
• Battery Harness Connections
• Battery Under Load

1 beep then 2
beeps

Master Motor
Terminals Shorted

• Connections to Master Inputs
• Master Arm Power Cable
• Motor
• Circuit Board

1 beep with 2
seconds off

Master Arm Limit
Switch Error

• Connections to Master Inputs
• Master Arm Power Cable

3 beeps with 2
seconds off

Master Arm Rev
Counter Error

• Connections to Master Inputs
• Master Arm Power Cable
• Rev Counter

• Normal Operation

• Path of Gate
• Gate for Level and Plumb
• Stall Force Adjustment
• Disconnect Safety Devices
• Rev Counter

LPA 4000XLS Instruction Manual

25

Generation 3 Visual Feedback
SYMPTOM
DIAGNOSIS
Status (clear)1 blink Cycle Terminal
Shorted

CHECK:
• Disconnect the push button, keypad, intercom keypad, or
any other accessory wired to this terminal.
• Try the remote. If the remote works, then the problem is
the accessory.
• Disconnect the loop detector, photo beam, or any other
accessory wired to this terminal.
• Try the remote. If the remote works, the problem is the
accessory.

Status (clear) 2
blinks

Safety Terminal
Shorted

Status (clear) 3
blinks

Exit Terminal
Shorted

Status (clear) 4
blinks

Shadow Terminal
Shorted

Status (clear) 5
blinks

Close Edge
Terminal Shorted

Status (clear) 6
blinks

Open Edge
Terminal Shorted

RF (yellow) Flickers

Receiving 318 MHz
RF

RF (yellow)OFF

No 318 MHz RF
Received

• Battery in Remote
• Program Remote
• Antenna Receiver Connections
• Antenna Receiver

Power (green)
ON

AC or Solar Power
Present

• Normal Operation

• Disconnect exit wand, loop detector, photo beam, or any
other accessory wired to this terminal.
• Try remote. If the remote works, the problem is the
accessory.
• Disconnect the loop detector, photo beam, or any other
accessory wired to this terminal.
• Try remote. If the remote works, the problem is the
accessory.
• Disconnect the edge sensor, photo beam, or any other
accessory wired to this terminal.
• Try the remote. If the remote works, the problem is the
accessory.
• Disconnect edge sensor, photo beam, or any other
accessory wired to this terminal.
• Try the remote. If the remote works, the problem is the
accessory.
• Normal operation when remote or wireless keypad is used.

VOLTAGE READINGS
18 Vac Transformer
18.0 to 22.0 Vac
10 W Solar panel (single)
18.0 to 22.0 Vdc
In FULL SUN — measure voltage with the Solar Panel Disconnected.
12 V, 7 amp hour Battery
12.5 to 13.5 Vdc
or Two 12V, 7 amp hour Batteries if using solar power
Measure voltage at battery terminals with battery disconnected
Charging circuit
12.0 to 14.8 Vdc
Measure voltage at battery terminals with battery connected
26 LPA 4000XLS Instruction Manual

Repair Service
If your LPA 4000XLS Gate Operator is not operating properly, please follow the steps below:
1. First use the procedures found in the Troubleshooting Guide (see page 25).
2. Use the 24/7 Troubleshooting Wizard at http://support.gtoinc.com.
3. If you are unable to solve the problem, call the LPA Service Department at (800) 543-1236. Refer to
the serial number (located on the right side of the control box) and date of purchase when calling
for assistance.
4. If repair or replacement of your gate operator is necessary, the Service Department will assign a
Return Goods Authorization (RGA) number to you.
5. Once you have received your RGA# you are required to send in your original equipment for
repair. Please refer to Manufactures’ Limited Warranty for complete details. Securely pack the
component(s) authorized for return to the factory. Include a copy of your sales reciept for the
purchase of the product(s). Write the RGA number issued to you on the outside of the package in
LARGE BOLD PRINT.
		 Ship the package(s) freight prepaid to: GTO, 3121 Hartsfield Road, Tallahassee, Florida, USA 32303.
		NOTE: Products returned to GTO without a Return Goods Authorization (RGA) number
in LARGE BOLD PRINT on the outside of the package WILL NOT be accepted. Also, items
returned to GTO freight collect WILL NOT be accepted.

GTO Technical Service
8:00am–7:00pm • Monday–Friday (EST)

3121 Hartsfield Road • Tallahassee, Florida, USA 32303
800-543-4283 • Fax (850) 575-8912
Web site www.linearproaccess.com
24/7 Troubleshooting Wizard: http://support.gtoinc.com

LPA 4000XLS Instruction Manual

27

Accessories for 4000XLS
Please visit www.gtoaccess.com for photos and detailed descriptions of LPA
Accessories. Or call 1-800-543-GATE (4283).

POWERING ACCESSORIES
Low Voltage Wire [RB509]
The 16 gauge, stranded, dual conductor low voltage Wire is for connecting the AC
powered transformer, solar panel or wired accessories to the system’s control board.
This specially designed wire is UV treated, PVC coated, and ready for direct burial.
Solar Panel Kits [FM122/FM123]
If your gate operator is more than 1000 ft. away from an AC power outlet, you can
choose to maintain the battery charge with the GTO Solar Panel Kit.
• 10 Watt Solar Panel Charging Kit [FM123]
• 5 Watt Solar Panel Charging Kit [FM122]
Additional/Replacement Battery [RB500]
For additional battery power or replacement.

“FROM VEHICLE” ENTRY AND EXIT ACCESSORIES
Transmitters [RB741/RB742/RB743]
Purchase an additional transmitter for each vehicle in your family. The Two-Button
Transmitter can be programmed to operate both your gate operator and a garage
door opener using the Universal Receiver. Or it can be programmed to open two
gate operator systems.
• Single Button Transmitter [RB741]
• Dual Button Transmitter [RB742]
• Three Button Transmitter [RB743]
Universal Receiver [RB709U-NB]
The Universal Antenna Receiver gives you the ability to use one remote to activate
your gate operator and your garage door opener. Connects to any brand garage
door opener. Up to 100 ft. range.

1
4

2

ABC

5

GHI

JKL

7
PRS

8

TUV

3

DEF

6

MNO

9

WXY

Digital Keypad [F310]
Allow friends access to your property using an identification code that you provide.
Program up to 25 entry codes for added security. Powered by three “AA” batteries
(not included).

0

28 LPA 4000XLS Instruction Manual

Ans

wer

Per Grant
mis
sio
n

Ke
Ba ypa
tt d
Low

POW
ER

Residential Wireless Entry Intercom [F3100MBC]
Designed for added security to your automated gate with the ability to “speak to”
and “screen” visitors safely from inside your home. Ideal for securing gate entrances
while providing controlled access.
DV

9V

Gooseneck Pedestal [F100/F110]
Designed to mount digital keypads, wireless intercom systems, and other access
control devices for your gate automation system.

“HANDS FREE” ENTRY & EXIT ACCESSORIES
Driveway Vehicle Sensor [FM139]
Automatically activates gate operator “Hands-Free” when a vehicle exits the
property. Electromagnetic sensor detects vehicles in motion.
• 50 ft. [FM139]
• 100 ft. [FM140]
• 150 ft. [FM141]
• 250 ft. [FM141-250]
Wireless Vehicle Sensor [R4500]
Automatically activates gate operator “Hands-Free” when a vehicle exits the
property. 100 ft. range between transmitter and receiver. Easy installation.

LOCKING & SECURITY ACCESSORIES
ATIC
OM CK ®
AUTE LOLO
CK
GASETCURITY
IC

TRON

ELEC

1
4

GHI

7

PRS

2

ABC

5

JKL

8

TUV

0

3

DEF

6

MNO

®

9

WXY

SEC
URITY

, Inc.

GATE
LOC
K

Automatic Gate Lock [FM144/FM142]
The #1 Accessory For Swing Gate Operators! Designed for added security in
conjunction with GTO Automatic Gate Operators. The gate lock unlocks and locks
automatically when the gate opens and closes. The perfect solution for high wind
conditions.
Bulldog Pedestrian Gate Lock [FM145]
Designed to mount on horizontal swing “walk through” wood, chain link, and metal
pedestrian gates opening in or out. Ideal for securing pools, condominiums, schools
and any pedestrian gate.
Wireless Driveway Alarm [R4450].
This device alerts you of vehicles entering your driveway (with or without an
automated gate). The indoor base station signals you with a door chime when a
vehicle passes the driveway sensor.

LPA 4000XLS Instruction Manual

29

ADDITIONAL ACCESSORIES
Photo Beams [R4222]
Primary “through beam” photo beam device. Provides “non-contact” entrapment
protection.
Pin Lock [FM345]
Use as a substitute for the clevis pin at the front mount of the PRO-SW4000XLS to
prevent theft of the operator.
• Pin Lock 10-pack: ten Pin Locks keyed alike [FM345KA].
Push Button Control [RB101]
Wire this unlit push button directly to your gate operator for simple open/close/stop
operation from up to 1000 ft. away. Use 16 gauge low-voltage wire.
Replacement Transformer [RB570]
Standard 18 volt, 2200 mA AC transformer included with the 4000XLS to maintain
battery charge.
Gate Grounding Kit [R4196]
The purpose of the grounding kit is to REDUCE THE RISK of damage to electronic
equipment from lightning strikes. There is no protection or grounding system that
can completely eliminate this risk.

HARDWARE ACCESSORIES
Push To Open Bracket [R4KPTO]
Required when the 4000XLS must push a gate open (arm extends to open), such as
away from a sloping driveway or where space prevents gate from opening into the
property (pull to open). Order two brackets for a dual swing gate installation.
Column Mount Lock Receiver [433IH]
For use with the Automatic Gate Lock or Bulldog Pedestrian Gate Lock when
mounting on brick columns or applications with limited space.

3121 Hartsfield Road • Tallahassee, Florida, USA 32303
800-543-4283 • Fax (850) 575-8912
Web site www.linearproaccess.com
24/7 Troubleshooting Wizard: http://support.gtoinc.com
30 LPA 4000XLS Instruction Manual



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c111 79.158366, 2015/09/25-01:12:00
Instance ID                     : uuid:6fdc4aeb-f184-4948-bb9a-fd2b8bc21b8a
Original Document ID            : adobe:docid:indd:227749ba-83b4-11df-ac71-a3c0be8a17cb
Document ID                     : xmp.id:ab26479a-3f51-4bb2-9308-4943000dea50
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:303e9cd1-3b91-4385-9818-cde8a14b8ef5
Derived From Document ID        : xmp.did:017e4f1c-8344-46dd-b1f5-1f09e4b5b06e
Derived From Original Document ID: adobe:docid:indd:227749ba-83b4-11df-ac71-a3c0be8a17cb
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Macintosh)
History Changed                 : /
History When                    : 2016:06:03 09:59-04:00
Create Date                     : 2016:06:03 09:59-04:00
Modify Date                     : 2016:06:03 09:59:21-04:00
Metadata Date                   : 2016:06:03 09:59:21-04:00
Creator Tool                    : Adobe InDesign CC 2015 (Macintosh)
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 40
Creator                         : Adobe InDesign CC 2015 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu