40RUA/40RUS 6 to 15 Ton Direct Expansion 7.5 to 15 Ton Chilled Water Packaged Air---Handling Units Product Data Carrier’s versatile packaged air-handling units satisfy design requirements with: C09035 40RU07 --- 12 S Multi-- position design for horizontal or vertical installation without modification. S Standard sloped drain pans and cleanable insulation treated with Environmental Protection Agency (EPA) registered antimicrobial agent improve indoor air quality. S High-static design meets a wider range of applications than competitive packaged air handler lines. S Economizer accessory provides ventilation air and “free” cooling. S Cooling coils with mechanically bonded fins provide peak heat transfer. S Hot water coil, steam coil, and electric heat accessories are available. S Standard factory-- installed thermo-- static expansion valve (TXV) with removable power element on 40RUA units. S Die-formed galvanized steel casings provide durability and structural integrity. Optional paint is available. FEATURES/BENEFITS Easy-to-install and economical 40RU units provide reliable service. The 40RU Series air-- handling units are the best choice for packaged air handlers. Model 40RUA units have direct-- expansion coils. All models offer excellent fan performance, a unique combination of indoor air quality features, easy installation, and affordable prices. Their versatility and state-- of-- the-- art features will provide economical performance now and in the future. Indoor air quality features C09036 40RU14, 16 the environmentally sound refrigerant The unique combination of features in the 40RU Series air handlers ensures that clean, fresh, conditioned air is delivered to the occupied space. Cooling coils prevent the build-- up of humidity in the room, even during part-- load conditions. Unit sizes of 10 tons and above feature dual-- circuit face-- split coils. Two-- in. (51-- mm) disposable filters remove dust and airborne particles from the occupied space. Thermal insulation contains an immobilized anti-- microbial agent to inhibit the growth of bacteria and fungi. The anti-- microbial agent is registered with the U.S. Environmental Protection Agency (EPA). collets and clamp locking devices. Smaller unit sizes have spider-- type bearings. Pitched drain pan can be adjusted for a right-- hand or left-- hand connection to provide positive drainage and prevent standing condensate. Model 40RU air handling units have galvanized steel casings; inlet and outlet connections are on the same end. Accessory economizer can provide ventilation air to improve indoor air quality. When used with CO2 sensors, the economizer admits fresh outdoor air to replace stale, recirculated indoor air. 40RU Accessory UV-- C germicidal lamps can eliminate foul odors that result from the growth of mold and fungus on evaporator coil and condensate pan surfaces. Economy The 40RU Series packaged air handlers have low initial costs, and they continue to save money by providing reduced installation expense and energy-- efficient performance. Quick installation is ensured by the multi-- position design. Units can be installed in either the horizontal or vertical (upflow) configuration without modifications. All units have drain-- pan connections on both sides, and pans can be pitched for right-- hand or left hand operation with a simple adjustment. Fan motors and contactors are pre-- wired and TXVs are factory-- installed on 40RU models. Coil flexibility Direct expansion (DX) coils are designed for use with Puronr R-- 410A refrigerant and have copper tubes mechanically bonded to aluminum sine-- wave fins. Direct-- expansion coils include matched, factory-- installed thermostatic expansion valves (TXVs) with matching distributor nozzles. Easier installation and service The multi-- position design and component layout allow for quick unit installation and operation. The DX coils have factory-- installed TXVs with matching distributor nozzles. Units can be converted from horizontal to vertical operation by simply repositioning the unit. Drain pan connections are duplicated on both sides of the unit. The filters, motor, drive, TXVs, and coil connections are easily accessed by removing a single side panel. TABLE OF CONTENTS PAGE FEATURES AND BENEFITS . . . . . . . . . . . . . . . . . . 1-- 2 MODEL NUMBER NOMENCLATURE . . . . . . . . . . . . 3 High-- efficiency, precision balanced fans minimize air turbulence, surging, and unbalanced operation, thereby cutting operating expenses. PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-- 7 Economizer accessory precisely controls the blend of outdoor air and room air to achieve comfort levels. When the outside air enthalpy is suitable, outside air dampers can fully open to provide “free” cooling. DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-- 20 Rugged dependability ELECTRICAL DATA . . . . . . . . . . . . . . . . . . . . . . . 30-- 34 Die-- formed galvanized steel panels ensure structural integrity under all operating conditions. Mechanically bonded coil fins provide improved heat transfer. Galvanized steel fan housings are securely mounted to a die-- formed galvanized steel deck. TYPICAL PIPING AND WIRING . . . . . . . . . . . . . 35-- 37 OPTIONS AND ACCESSORIES . . . . . . . . . . . . . . . . 8-- 9 SELECTION PROCEDURE . . . . . . . . . . . . . . . . . . . . . 21 PERFORMANCE DATA . . . . . . . . . . . . . . . . . . . . . 22-- 29 TYPICAL CONTROL WIRING SCHEMATIC . . . . . . 38 APPLICATION DATA . . . . . . . . . . . . . . . . . . . . . . 39-- 44 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . 45 Rugged pillow-- block bearings (14 and 16 size) are securely fastened to the solid steel fan shaft with split 2 MODEL NUMBER NOMENCLATURE 1 2 4 0 R U A A 1 3 4 _____________ 5 6 7 8 9 10 11 12 13 14 15 16 17 18 4 A 1 A 6 -- 0 A 0 A 0 ____ Model Type Brand / Packaging 40RU = Carrier Fan Coil Puronr R--- 410A Refrigerant 0 = Standard Type of Coil A = Standard DX Coil (4 row) S = Chilled Water Coil Factory Assigned A = Standard Service Options 0 = None 1 = Painted Cabinet Nominal Tonnage 07 = 6 Tons (40RUA only) 08 = 7.5 Tons 10 = 8.5 Tons (40RUS only) 12 = 10 Tons 14 = 12.5 Tons 16 = 15 Tons Factory Assigned A = Standard Factory Assigned 0 = Standard Factory Assigned A = Standard Design Rev --- = Catalog Model Number Indoor Fan Options 1 = Standard Motor/Drive 2 = Standard Motor/Medium Static Drive 3 = High Static Motor/Drive Voltage 1 = 575/3/60 3 = 208--- 230/1/60 (07 and 08 Only) 5 = 208--- 230/3/60 (Size 16 w/High Static Motor Only) 6 = 208/230/460/3/60 (all sizes 07--- 14, size 16 with std. motor option Coil Options A = Al/Cu Standard 4 row coil This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturer’s refrigerant charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. the environmentally sound refrigerant 3 40RU Refrigerant Options A = None PHYSICAL DATA 40RU 40RUA --- U.S. UNIT 40RUA NOMINAL CAPACITY (Tons) OPERATING WEIGHT (lb) Base Unit with TXV (4 Row) Plenum Economizer Hot Water Coil Steam Coil FANS Qty...Diam. (in.) Nominal Airflow (cfm) Airflow Range (cfm) Nominal Motor Hp (Standard Motor) 208/230--- 1--- 60 208/230--- 3--- 60 and 460--- 3--- 60 575--- 3--- 60 230--- 3--- 50 and 400--- 3--- 50 Motor Speed (rpm) 208/230--- 1--- 60 208/230--- 3--- 60 and 460--- 3--- 60 575--- 3--- 60 230--- 3--- 50, 400--- 3--- 50 Nominal Motor Hp (High Static Motor) 208/230--- 1--- 60 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 230--- 3--- 50 and 400--- 3--- 50 Motor Speed (rpm) 208/230--- 1--- 60 208/230--- 3--- 60 and 460--- 3--- 60 575--- 3--- 60 230--- 3--- 50, 400--- 3--- 50 REFRIGERANT Operating charge (lb) (approx per circuit)* DIRECT--- EXPANSION COIL Max Working Pressure (psig) Face Area (sq ft) Rows No. of Circuits Split Type...Percentage No. of Circuits per Split Fins/in. STEAM COIL Max Working Pressure (psig at 260 F) Total Face Area (sq ft) Rows...Fins/in. HOT WATER COIL Max Working Pressure (psig) Total Face Area (sq ft) Rows...Fins/in. Water Volume (gal) (ft3) PIPING CONNECTIONS Quantity...Size (in.) DX Coil — Suction (ODF) DX Coil — Liquid Refrigerant (ODF) Steam Coil, In (MPT) Steam Coil, Out (MPT) Hot Water Coil, In (MPT) Hot Water Coil, Out (MPT) Condensate (PVC) FILTERS Quantity...Size (in.) 07 6 08 7.5 12 10 14 12.5 16 15 399 175 185 195 215 404 175 185 195 215 425 175 185 195 215 695 225 340 285 340 713 225 340 285 340 1...15 2400 1800--- 3000 1...15 3000 2250--- 3750 1...15 4000 3000--- 5000 2...15 5000 3750--- 6250 2...15 6000 4500--- 7500 1.3 2.4 1.0 2.4 1.3 2.4 2.0 2.4 — 2.4 2.0 2.9 — 2.9 3.0 2.9 --3.7 3.0 2.9 1725 1725 1725 1725 1725 1725 — 1725 1725 1425 — 1725 1725 — 1725 1725 2.4 2.9 2.9 2.0 n/a 2.4 2.9 2.9 3.0 2.9 — 3.7 2.9 3.0 5.0 — 3.7 3.7 5.0 5.0 --5.0 3.7 5.0 5.0 1725 1725 1725 1725 1725 1725 3.0 6.67 1 — 12 15 — — — 1725 1725 1725 1725 1725 1745 1425 Puron R--- 410A 3.0 1.5/1.5 2.0/2.0 2.5/2.5 Enhanced Copper Tubes, Aluminum Sine--- Wave Fins 435 8.33 10.01 13.25 17.67 4 1 2 2 2 — Face...50/50 15 9 12 16 15 17 15 15 6.67 1...9 6.67 1...9 20 6.67 1...9 13.33 1...10 13.33 1...10 6.67 2...8.5 6.67 2...8.5 150 6.67 2...8.5 13.33 2...8.5 13.33 2...8.5 8.3 1.1 1...1 1/8 1...5/8 1...21/2 1...11/2 1...11/2 1...11/2 1...11/8 13.9 1.85 2...11/8 1...11/2 1...11/2 1...11/4 ODM/1 IDF Throwaway — Factory--- Supplied Right or Left Side 4 2...11/8 1...2 1...2 4...16 x 20 x 2 4...16 x 24 x 2 4...16 x 24 x 2 Access Location * Units are shipped without refrigerant charge. 2...11/8 2...5/8 1...21/2 1...11/2 PHYSICAL DATA (cont.) 07 21 08 26 12 35 14 43 16 52 181 80 84 89 98 183 80 84 89 98 193 80 84 89 98 315 102 155 130 155 323 102 155 130 155 1...381 1133 850--- 1416 1...381 1604 1203--- 2006 1...381 1888 1416--- 2360 2...381 2360 1770--- 2949 2...381 2831 2124--- 3539 0.97 1.79 0.75 0.97 1.79 1.49 — 1.79 1.49 — 2.16 2.24 --2.76 2.24 28.8 28.8 28.8 28.8 28.8 28.8 — 28.8 28.8 — 28.8 28.8 — 28.8 28.8 1.79 2.16 2.16 1.49 1.79 2.16 2.16 2.24 — 2.76 2.16 2.24 — 2.76 2.76 3.73 --3.73 2.76 3.73 28.8 28.8 28.8 28.8 28.8 28.8 — — 28.8 28.8 28.8 28.8 Puron R--- 410A 1.36 0.68/0.68 0.90/0.90 Enhanced Copper Tubes, Aluminum Sine--- Wave Fins 2999 0.77 0.93 1.23 4 1 2 2 15 9 12 — Face...50/50 591 670 591 1.36 0.62 1 12 — 591 — 28.8 28.8 1.13/1.13 1.64 2 16 591 0.62 1...355 0.62 1...355 138 0.62 1...355 1.24 1...394 1.24 1...394 0.62 2...335 0.62 2...335 1034 0.62 2...335 1.24 2...335 1.24 2...335 31.4 0.031 1...11/8 1...5/8 1...21/2 1...11/2 1...11/2 1...11/2 Quantity...Size (mm) 52.6 0.052 1...11/8 2...11/8 2...11/8 2...5/8 1...21/2 1...11/2 1...11/2 1...11/2 1...11/4 ODM/1 IDF Throwaway — Factory--- Supplied Access Location Right or Left Side in 5/ 8 11/8 1 1 /2 2 21/2 5 1...2 1...2 4...406 x 508 x 51 4...406 x 610 x 51 4...406 x 610 x 51 * Units are shipped without refrigerant charge. ** All piping sizes are OD inches; equivalent sizes in millimeters follow: 2...11/8 mm 15.9 28.6 38.7 50.8 63.5 40RU 40RUA --- SI UNIT 40RUA NOMINAL CAPACITY (kW) OPERATING WEIGHT (kg) Base Unit with TXV (4 Row) Plenum Economizer Hot Water Coil Steam Coil FANS Qty...Diam. (mm) Nominal Airflow (L/s) Airflow Range (L/s) Nominal Motor kW (Standard Motor) 208/230--- 1--- 60 208/230--- 3--- 60 and 460--- 3--- 60 575--- 3--- 60 Motor Speed (rpm) 208/230--- 1--- 60 208/230--- 3--- 60 and 460--- 3--- 60 575--- 3--- 60 Nominal Motor Hp (High Static Motor) 208/230--- 1--- 60 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 Motor Speed (rpm) 208/230--- 1--- 60 208/230--- 3--- 60 and 460--- 3--- 60 575--- 3--- 60 REFRIGERANT Operating charge (kg) (approx per circuit)* DIRECT--- EXPANSION COIL Max Working Pressure (kPag) Face Area (sq m) Rows No. of Splits No. of Circuits per Split Split Type...Percentage Fins/m STEAM COIL Max Working Pressure (kPag at 126 C) Total Face Area (sq m) Rows...Fins/m HOT WATER COIL Max Working Pressure (kPag) Total Face Area (sq m) Rows...Fins/m Water Volume (L) (m3) PIPING CONNECTIONS** Quantity...Size (in.) DX Coil — Suction (ODF) DX Coil — Liquid Refrigerant (ODF) Steam Coil, In (MPT) Steam Coil, Out (MPT) Hot Water Coil, In (MPT) Hot Water Coil, Out (MPT) Condensate (PVC) FILTERS PHYSICAL DATA (cont.) 40RU 40RUS --- U.S. UNIT 40RUS NOMINAL CAPACITY (Tons) OPERATING WEIGHT (lb) Base Unit Plenum Economizer Hot Water Coil Steam Coil FANS Qty...Diam. (in.) Nominal Airflow (cfm) Airflow Range (cfm) Nominal Motor Hp (Standard Motor) 208/230-1-60 208/230-3-60 and 460-3-60 575-3-60 Motor Speed (rpm) 208/230-1-60 208/230-3-60 and 460-3-60 575-3-60 Nominal Motor Hp (High Static Motor) 208/230-1-60 208/230-3-60 and 460-3-60 575-3-60 Motor Speed (rpm) 208/230-1-60 208/230-3-60 and 460-3-60 575-3-60 CHILLED WATER COIL Max Working Pressure (psig) Face Area (sq ft) — Upper Face Area (sq ft) — Lower Rows...Fins/in. Water Volume (gal) (ft3) STEAM COIL Max Working Pressure (psig at 260 F) Total Face Area (sq ft) Rows...Fins/in. HOT WATER COIL Max Working Pressure (in. wg) Total Face Area (sq ft) Rows...Fins/in. Water Volume (gal) (ft3) PIPING CONNECTIONS Quantity...Size (in.) Chilled Water — In Chilled Water — Out Steam Coil, In (MPT) Steam Coil, Out (MPT) Hot Water Coil, In (MPT) Hot Water Coil, Out (MPT) Condensate (PVC) FILTERS Quantity...Size (in.) 008 010 012 014 016 71/2 81/2 10 121/2 15 390 175 185 195 215 391 175 185 195 215 391 175 185 195 215 661 225 340 285 340 677 225 340 285 340 1...15 3000 2250-3750 1...15 3400 2250-4250 1...15 4000 3000-5000 2...15 5000 3750-6250 2...15 6000 4500-7500 2.4 2.4 2.0 2.4 2.4 2.0 — 2.4 2.0 — 2.9 3.0 — 3.7 3.0 1725 1725 1725 1725 1725 1725 — 1725 1725 — 1725 1725 — 1725 1725 2.4 2.9 2.9 2.4 3.7 2.9 — 3.7 3.7 — 3.7 3.7 — 5.0 3.7 1725 1725 1725 8.3 — 1725 — — 1725 1725 1725 1725 1725 1725 Enhanced Copper Tubes, Aluminum Sine-Wave Fins 435 9.0 9.8 8.3 — — 5.5 3...15 — 1725 1745 8.3 8.3 3.0 0.40 3.3 0.47 3.5 0.46 4.7 0.63 5.6 0.75 6.67 1...9 6.67 1...9 20 6.67 1...9 13.33 1...10 13.33 1...10 6.67 2...8.5 6.67 2...8.5 150 6.67 2...8.5 13.33 2...8.5 13.33 2...8.5 8.3 1.1 1...13/8 ODF 1...13/8 ODF 13.9 1.85 1...13/8 ODF 1...13/8 ODF 1...11/2 1...11/2 1...13/8 ODF 1...13/8 ODF 1...21/2 1...11/2 1...11/4 ODM/1 IDF Throwaway — Factory-Supplied 4...16 x 24 x 2 Access Location Right or Left Side 6 2...13/8 ODM 2...13/8 ODM 2...13/8 ODM 2...13/8 ODM 1...2 1...2 4...16 x 20 x 2 4...16 x 24 x 2 PHYSICAL DATA (cont.) 008 010 012 014 016 26 29 35 43 52 177 80 84 89 98 177 80 84 89 98 177 80 84 89 98 300 102 155 130 155 307 102 155 130 155 1...381 1416 1062-1770 1...381 1605 1204-2006 1...381 1888 1416-2360 2...381 2360 1770-2949 2...381 2831 2124-3539 1.79 1.79 1.49 1.79 1.79 1.49 — 1.79 1.49 — 2.16 2.24 — 2.76 2.24 28.8 28.8 28.8 28.8 28.8 28.8 — 28.8 28.8 — 28.8 28.8 — 28.8 28.8 1.79 2.16 2.24 1.79 2.76 2.24 — 2.76 3.73 — 2.76 3.73 — 2.73 3.73 28.8 28.8 28.8 23.8 28.8 28.8 28.8 23.8 — 28.8 28.8 23.8 — 28.8 28.8 23.8 — 28.8 28.8 23.8 0.77 — 3...591 0.84 — 3...591 2999 0.91 — 3...591 0.77 0.51 3...591 0.77 0.77 3...591 11.4 0.011 12.5 0.013 13.2 0.013 17.8 0.018 21.2 0.021 0.62 1...355 0.62 1...355 0.62 1...355 1.24 1...355 1.24 1...394 0.62 2...335 0.62 2...335 1034 0.62 2...335 1.24 2...335 1.24 2...335 138 31.4 0.031 1...13/8 ODF 1...13/8 ODF 1...13/8 ODF 1...13/8 ODF 1 1...2 /2 1...11/2 1...11/2 1...11/2 52.6 0.052 2...13/8 ODF 2...13/8 ODM 2...13/8 ODM 2...13/8 ODF 2...13/8 ODM 2...13/8 ODM 1 1 1...2 /2 1...2 /2 1...11/2 1...11/2 1...11/2 1...2 1...11/2 1...2 1...11/4 ODM/1 IDF Throwaway — Factory-Supplied 4...406 x 508 x 51 Quantity...Size (mm) 4...406 x 610 x 51 4...406 x 610 x 51 Access Location Right or Left Side * All piping sizes are OD inches; equivalent sizes in millimeters, see above. 7 40RU 40RUS --- SI UNIT 40RUS NOMINAL CAPACITY (kW) OPERATING WEIGHT (kg) Base Unit Plenum Economizer Hot Water Coil Steam Coil FANS Qty...Diam. (mm) Nominal Airflow (L/s) Airflow Range (L/s) Nominal Motor kW (Standard Motor) 208/230-1-60 208/230-3-60,460-3-60 575-3-60 Motor Speed (r/s) 208/230-1-60 208/230-3-60, 460-3-60 575-3-60 Nominal Motor kW (High Static Motor) 208/230-1-60 208/230-3-60,460-3-60 575-3-60 Motor Speed (r/s) 208/230-1-60 208/230-3-60, 460-3-60 575-3-60 230-3-50, 400-3-50 CHILLED WATER COIL Max Working Pressure (kPag) Face Area (sq m) — Upper Face Area (sq m) — Lower Rows...Fins/m Water Volume (L) (m3) STEAM COIL Max Working Pressure (kPag at 126 C) Total Face Area (sq m) Rows...Fins/m HOT WATER COIL Max Working Pressure (kPag) Total Face Area (sq m) Rows...Fins/m Water Volume (L) (m3) PIPING CONNECTIONS* Quantity...Size (in.) Chilled Water — In Chilled Water — Out Steam Coil, In (MPT) Steam Coil, Out (MPT) Hot Water Coil, In (MPT) Hot Water Coil, Out (MPT) Condensate (PVC) FILTERS 40RU OPTIONS AND ACCESSORIES ITEM Alternate Fan Motors Alternate Drives CO2 Sensors Condensate Drain Trap Discharge Plenum Economizer Electric Heat Hot Water Heating Coils Overhead Suspension Package Prepainted Units Programmable Thermostats Return Air Grille Steam Heating Coil Subbase UV--- C Germicidal Lamp** * Factory--- installed option. { Field --- installed accessory ** Contact Application Engineer OPTION* X X ACCESSORY{ X X X X X X X X X X X X X Factory--installed options Alternate fan motors and drives are available to provide the widest possible range of performance. Prepainted steel units are available from the factory for applications that require painted units. Units are painted with American Sterling Gray color. Field--installed accessories Two-- row hot water coils have copper tubes mechanically bonded to aluminum plate fins and non-- ferrous headers. One-- row steam coil has copper tubes and aluminum fins. The Inner Distributing Tube (IDT) design provides uniform temperatures across the coil face. The steam coil has a broad operating pressure range; up to 20 psi (138 kPag) at 260_F (126_C). The IDT steam coils are especially suited to applications where sub-- freezing air enters the unit. Electric resistance heat coils have an open-- wire design and are mounted in a rigid frame. Safety cutouts for high temperature conditions are standard. Terminal block for single-- point power connection is included. Economizer (enthalpy controlled) provides ventilation air and “free” cooling if outside ambient temperature and humidity are suitable. It can also be used with CO2 sensors to help meet indoor air quality requirements. Discharge plenum directs the air discharge directly into the occupied space; integral horizontal and vertical louvers enable redirection of airflow. Accessory is available unpainted or painted. Field assembly is required (only applicable for vertical application). Return-- air grille provides a protective barrier over the return-- air opening and gives a finished appearance to units installed in the occupied space. Accessory is available unpainted or painted. Subbase provides a stable, raised platform and room for condensate drain trap connection for vertical floor-- mounted units. Accessory is available unpainted or painted. Overhead suspension package includes necessary brackets to support units in horizontal ceiling installations. CO2 sensors can be used in conjunction with the economizer accessory to help meet indoor air quality requirements. The sensor signals the economizer to open when the CO2 level in the space exceeds the set point. A Carrier Comfort System programmable thermostat can be used to override the sensor if the outside-- air temperature is too high or too low. Carrier’s line of thermostats provide both programmable and non-- programmable capability with the new Debonairr line of commercial programmable thermostats. The TEMP System controls offer communication capability with staged heating and cooling, and the Commercial Electronic thermostats provide 7-- day programmable capability for economical applications. Condensate drain trap includes an overflow shutoff switch that can be wired to turn off the unit if the trap becomes plugged. Kit also includes a wire harness that can be connected to an alarm if desired. The transparent trap is designed for easy service and maintenance. UV-- C germicidal lamps inhibit the growth of mold and fungus, which may grow on evaporator coil and condensate pan surfaces. The use of UV-- C germicidal lamps reduces the foul odors that may result from this growth of mold and fungus. It also provides a self-- cleaning function for the evaporator coil and drain pan. 8 OPTIONS AND ACCESSORIES (cont.) 40RU WITH DISCHARGE PLENUM RETURN-AIR GRILLE AND SUBBASE 40RU WITH HOT WATER OR STEAM COIL HOT WATER OR STEAM COIL 40RU DISCHARGE PLENUM RETURN-AIR GRILLE SUBBASE FAN COIL UNIT FAN COIL UNIT 40RU WITH ECONOMIZER AND UV-C GERMICIDAL LAMPS 40RU WITH CONDENSATE TRAP ECONOMIZER UV-C GERMICIDAL LAMPS C09038 9 40RU DIMENSIONS C09060 40RU*07--12 10 40RU DIMENSIONS (cont.) C09061 40RU*14, 16 11 DIMENSIONS (cont.) CORNER WEIGHTS HORIZONTAL POSITION 6 4 3 8 2 7 Coil Fan Fan 5 1 40RU Steam Coil or Hot Water Coil Base Unit Fan Coil Economizer C09039 40RU --- U.S. 40RU UNIT SIZE 40RUA07 40RUA08 40RUS08 40RUS10 40RUA12 40RUS12 40RUA/S 07, 08, 12 40RUA14 40RUS14 40RUA16 40RUS16 40RUA/S 14, 16 UNIT OR ACCESSORY NAME FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT STEAM COIL ADD HOT WATER COIL ADD ECONOMIZER ADD ECO + STEAM COIL ADD ECO + HW COIL ADD FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT STEAM COIL ADD HOT WATER COIL ADD ECONOMIZER ADD ECO + STEAM COIL ADD ECO + HW COIL ADD UNIT OR ACCESSORY WEIGHT (lb) 399 404 390 391 425 391 215 195 185 400 380 695 661 713 677 340 285 340 680 625 CORNER NUMBER (WEIGHT IN LB) 1 2 3 4 5 6 7 8 109.3 110.7 106.9 107.2 116.4 107.2 40.2 35.9 0.0 38.8 36.9 224.0 213.1 229.8 218.2 61.4 51.7 0.0 64.4 60.0 106.1 107.5 103.8 104.1 113.0 104.1 0.0 0.0 36.8 38.6 35.8 177.7 169.0 182.3 173.1 0.0 0.0 66.9 63.7 57.6 90.6 91.7 88.5 88.7 96.5 88.7 0.0 0.0 35.7 37.4 34.6 129.8 123.5 133.2 126.5 0.0 0.0 62.0 59.0 53.4 93.4 94.5 90.8 91.0 99.4 91.0 40.6 36.7 0.0 39.2 37.7 163.7 155.4 167.9 159.2 62.0 51.3 0.0 65.0 59.5 — — — — — — 66.5 60.4 0.0 64.2 62.1 — — — — 107.8 91.5 0.0 113.0 106.2 — — — — — — 67.5 62.0 0.0 65.2 63.8 — — — — 108.8 90.6 0.0 114.1 105.1 — — — — — — 0.0 0.0 56.8 59.5 55.1 — — — — 0.0 0.0 109.8 104.5 94.6 — — — — — — 0.0 0.0 55.1 57.7 53.4 — — — — 0.0 0.0 102.0 97.1 87.8 12 DIMENSIONS (cont.) 40RU --- SI 40RUA07 40RUA08 40RUS08 40RUS10 40RUA12 40RUS12 40RUA/S 07, 08, 12 40RUA14 40RUS14 40RUA16 40RUS16 40RUA/S 14, 16 UNIT OR ACCESSORY NAME FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT STEAM COIL ADD HOT WATER COIL ADD ECONOMIZER ADD ECO + STEAM COIL ADD ECO + HW COIL ADD FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT STEAM COIL ADD HOT WATER COIL ADD ECONOMIZER ADD ECO + STEAM COIL ADD ECO + HW COIL ADD UNIT OR ACCESSORY WEIGHT (kg) 181 183 177 177 193 177 98 89 84 182 173 315 300 323 307 155 130 155 310 285 CORNER NUMBER (WEIGHT IN KG) 1 2 3 4 5 6 7 8 49.6 50.1 48.5 48.5 52.9 48.5 18.2 16.4 0.0 17.6 16.8 86.3 82.2 88.5 84.1 28.1 23.6 0.0 29.3 27.5 48.1 48.6 47.0 47.0 51.3 47.0 0.0 0.0 16.7 17.5 16.3 83.7 79.7 85.9 81.6 0.0 0.0 30.2 29.0 26.4 41.1 41.5 42.5 42.5 43.8 42.5 0.0 0.0 16.2 17.0 15.8 71.5 68.1 73.3 69.7 0.0 0.0 28.3 26.9 24.4 42.3 42.8 39 39 45.2 39 18.4 16.7 0.0 17.8 17.2 73.7 70.0 75.6 71.6 28.3 23.4 0.0 29.6 27.1 — — — — — — 30.2 27.5 0.0 29.1 28.3 — — — — 49.3 41.8 0.0 51.5 48.5 — — — — — — 30.6 28.2 0.0 29.6 29.0 — — — — 49.3 41.2 0.0 51.9 47.9 — — — — — — 0.0 0.0 25.8 27.0 25.1 — — — — 0.0 0.0 50.3 47.6 43.1 — — — — — — 0.0 0.0 25 26.2 24.3 — — — — 0.0 0.0 46.2 44.2 40.1 LEGEND: ECO --- Economizer HW --- Hot Water 13 40RU 40RUA UNIT SIZE DIMENSIONS (cont.) CORNER WEIGHTS VERTICAL POSITION 6 5 Economizer 1 4 Mtr Base Unit 3 2 40RU NOTE: Steam, Hot Water & Plenum on top of positions 1,2,3,4 C09040 40RU --- U.S. 40RU UNIT SIZE 40RUA07 40RUA08 40RUS08 40RUS10 40RUA12 40RUS12 40RUA/S 07,08,12 40RUA14 40RUS14 40RUA16 40RUS16 40RUA/S 14, 16 UNIT OR ACCESSORY NAME FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT STEAM COIL HOT WATER COIL PLENUM ECONOMIZER ECO + STEAM COIL ECO + HW COIL FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT STEAM COIL HOT WATER COIL PLENUM ECONOMIZER ECO + STEAM COIL ECO + HW COIL ADD ADD ADD ADD ADD ADD ADD ADD ADD ADD ADD ADD UNIT OR ACCESSORY WEIGHT (lb) 399 404 390 391 425 391 215 195 175 195 410 390 695 661 713 677 340 285 225 340 680 625 14 CORNER NUMBER (WEIGHT IN LB) 1 2 3 4 5 6 100.5 101.7 98.2 98.9 107.6 98.9 54.1 49.4 50.8 38.9 93.0 88.9 191.2 181.8 196.2 186.3 85.4 70.9 72.5 66.5 153.0 139.9 114.9 116.3 116.2 116.5 122.3 116.5 54.1 49.4 36.7 0.0 53.4 52.3 210.5 200.3 216.0 205.1 85.4 70.9 40.0 0.0 89.1 82.5 98.0 99.1 99.1 99.4 108.0 99.4 53.4 48.1 36.7 0.0 52.6 50.9 153.8 146.3 157.8 149.8 84.6 71.6 40.0 0.0 88.7 83.3 85.8 86.9 76.5 76.2 87.1 76.2 53.4 48.1 50.8 37.1 91.1 86.5 139.5 132.6 143.1 135.8 84.6 71.6 72.5 62.0 147.7 136.7 — — — — — — 0.0 0.0 0.0 59.9 61.0 56.7 — — — — 0.0 0.0 0.0 109.5 104.5 94.7 — — — — — — 0.0 0.0 0.0 58.3 59.1 54.9 — — — — 0.0 0.0 0.0 102.0 97.0 87.9 DIMENSIONS (cont.) 40RU --- SI 40RUA07 40RUA08 40RUS08 40RUS10 40RUA12 40RUS12 40RUA/S 07,08,12 40RUA14 40RUS14 40RUA16 40RUS16 40RUA/S 14, 16 UNIT OR ACCESSORY NAME FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT STEAM COIL HOT WATER COIL PLENUM ECONOMIZER ECO + STEAM COIL ECO + HW COIL FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT FAN COIL BASE UNIT STEAM COIL HOT WATER COIL PLENUM ECONOMIZER ECO + STEAM COIL ECO + HW COIL ADD ADD ADD ADD ADD ADD ADD ADD ADD ADD ADD ADD UNIT OR ACCESSORY WEIGHT (kg) 181 183 177 177 193 177 98 89 80 84 182 173 315 300 323 307 155 130 102 155 310 285 LEGEND: ECO --- Economizer HW --- Hot Water 15 CORNER NUMBER (WEIGHT IN LB) 1 2 3 4 5 6 45.5 46.0 44.5 44.5 48.5 44.5 24.6 22.4 23.3 16.8 41.3 39.3 86.6 82.5 88.9 84.5 39.0 32.4 32.9 31.1 69.8 63.8 52.3 52.7 51.0 51.0 55.6 51.0 24.6 22.4 16.8 0.0 23.6 23.1 95.5 91.0 97.9 93.1 39.0 32.4 18.1 0.0 40.7 37.6 44.4 44.9 43.4 43.4 47.4 43.4 24.4 22.1 16.8 0.0 23.3 22.5 69.8 66.5 71.6 68.1 38.5 32.6 18.1 0.0 40.4 37.8 38.8 39.4 38.1 38.1 41.5 38.1 24.4 22.1 23.3 16.2 40.3 38.2 63.3 60.0 64.9 61.3 38.5 32.6 32.9 28.5 67.3 62.2 — — — — — — 0.0 0.0 0.0 25.8 27.0 25.0 — — — — 0.0 0.0 0.0 49.7 47.6 43.1 — — — — — — 0.0 0.0 0.0 25.2 26.5 24.9 — — — — 0.0 0.0 0.0 45.7 44.2 40.5 40RU 40RU UNIT SIZE DIMENSIONS (cont.) 40RU UNIT SIZES 07-12 (FRONT) UNIT SIZES 14-16 (FRONT) C09041 16 DIMENSIONS (cont.) PLENUM, RETURN-AIR GRILLE, AND SUBBASE ACCESSORIES 40RU UNIT SIZES 07-12 UNIT SIZE 14, 16 NOTE: Dimensions in [ ] are millimeters. C09042 17 DIMENSIONS (cont.) HOT WATER AND STEAM COIL ACCESSORIES 40RU UNIT SIZES 07 - 12 UNIT SIZE 14, 16 NOTE: Dimensions in [ ] are millimeters. C09043 18 DIMENSIONS (cont.) ECONOMIZER ACCESSORY 40RU UNIT SIZES 07-12 UNIT SIZES 14, 16 NOTE: 1. For horizontal unit applications, economizer can be attached to end of unit opposite duct connections. 2. Dimensions in [ ] are millimeters. C09044 19 DIMENSIONS (cont.) ELECTRIC HEAT ACCESSORY 40RU UNIT SIZES 07 - 12 UNIT SIZE 14, 16 C09045 40RU UNIT SIZE A B 1’-31/4″ 4’-63/8″ [387.4] [1381.1] NOTE: Dimensions in [ ] are millimeters. 14, 16 C D E F G H J 25/16″ [58.7] 2’-11/4″ [641.4] 105/8″ [269.9] 1’-4″ [406.4] 1’-45/16″ [414.3] 1’-63/4″ [476.3] 1-7/8″ [327.0] 20 SELECTION PROCEDURE (WITH EXAMPLE) Cooling (DX) Fan I. I. Total Capacity . . . . . . . . . . . . . . . . . . . . 200,000 Btuh External static pressure = 1.03 in. wg Air Temperature Entering Indoor Coil . . . . . . . . . . . 80_F (27_C)db, 67_F (19_C) wb Enter 40RU16 Fan Performance table at 6000 cfm and 1.03 in. wg. Interpolate and determine fan speed of 864 rpm and 3.1 bhp. II. Determine motor and drive. Enter the fan motor data tables and find that the 230 v standard motor for a 40RU16 unit is rated at 3.7 Hp. Since the bhp required is 3.1, a standard motor satisfies the requirement and should be used. Ductwork Static Pressure Loss . . . . . . . . . . 0.8 in. wg Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . 230-3-60 Determine unit selection and coil refrigerant temperature. Enter the Cooling Capacities table at 6000 cfm. Select a 40RU16 unit which has a total capacity of 207,000 and 174,000 Btuh at 40 and 45_F (4 and 7_C) coil refrigerant temperature, respectively. By interpolation, coil refrigerant temperature of 41.1_F (5.1_C) is needed to give a total capacity of 200,000 Btuh. Sensible capacity is approximately 149,000 Btuh. Cooling load is satisfied. Next, find the type of drive that satisfies the 864 rpm requirement in the Drive Data tables. For a 40RU016 unit, the Medium-Static Drive table shows an rpm range of 742 to 943. Since the rpm required is 864, the medium-static drive satisfies the requirement and should be used. Select the standard motor and medium-static drive combination (option code HC or FD). Heating (Hot Water Coil) I. = 0.80 + 0.23 Sensible Heat Capacity . . . . . . . . . . . . . 130,000 Btuh Air Quantity Entering Indoor Coil . . . . . . . . 6000 cfm II. Determine fan speed and brake horsepower: From the Accessory Pressure Drop table, read a loss of 0.23 in. wg for a hot water coil at 6000 cfm. Determine heating load and temperature of air entering the indoor coil. Given: Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . 425,000 Btuh Entering-Air Temperature . . . . . . . . . . . . 70_F (21_C) Coils 2-Row Hot Water To select an outdoor unit for this 40RU16 indoor section, refer to the Combination Rating sheets for Carrier condensing units in the condensing unit Product Data Digest, or consult the Carrier Electronic Catalog. Cooling (Chilled Water) NOTE: Chilled water coils (40RUS) can be selected by using Carrier’s Electronic Catalog software program. Coil Entering-Water Temperature . . . . . 200_F (93_C) Water Temperature Drop . . . . . . . . . . . . . 20_F (-- 7_C) II. Find the heating capacity. Enter Hydronic Heating Capacities table for the 40RU16 unit at 6000 cfm. A 2-row hot water coil delivers 471,000 Btuh (based on 60_F/16_C entering air temperature and 20_F /-- 7_C water temperature drop). Since existing entering air temperature is 70_F (21_C), enter the Heating Correction Factors table for hot water coils at 200_F (93_C) entering water temperature, 20_F (-- 7_C) water temperature drop and 70_F (21_C) entering air. Read a constant of 0.93. 471,000 x 0.93 = 438,000 The 438,000 Btuh rating satisfies the heating load. 21 40RU Determine the cooling load and temperature and quantity of air entering the evaporator. Given: PERFORMANCE DATA HYDRONIC HEATING CAPACITIES — U.S. UNIT SIZE AIRFLOW (Cfm) 40RUA 07 40RUA/S 08 40RU 40RUS 10 40RUA/S 12 40RUA/S 14 40RUA/S 16 1,800 2,400 3,000 2,250 3,000 3,750 2,550 3,400 4,250 3,000 4,000 5,000 3,750 5,000 6,250 4,500 6,000 7,500 1-ROW STEAM* Cap. Ldb 146 173 209 168 209 240 183 229 254 209 243 279 370 425 465 402 458 479 134 126 123 129 123 117 125 121 114 123 115 111 150 137 128 141 129 118 HYDRONIC HEATING CAPACITIES — SI 2-ROW HOT WATER COIL† Water Cap. Ldb Flow PD (Gpm) 156.0 183.0 206.0 174.0 206.0 238.0 199.0 233.0 271.0 299.0 275.0 316.0 362.0 409.0 456.0 412.0 471.0 529.0 140 131 124 133 124 118 132 123 119 152 124 119 149 136 128 145 133 125 15.6 18.3 20.6 17.4 20.6 23.8 19.9 23.3 27.1 29.9 27.5 31.6 36.2 40.9 45.6 41.2 47.1 52.9 3.4 4.3 5.2 4.0 5.2 6.5 4.5 5.7 7.2 5.0 6.6 8.2 4.2 5.1 6.0 4.5 5.5 6.6 LEGEND: Cap. --- Capacity (Btuh in thousands) Ldb --- Leaving Air Dry Bulb Temp (F) PD . --- Pressure Drop (ft water) * Based on 5 psig steam, 60° F entering-air temperature. All steam coils are non-freeze type. † Based on 200° F entering water, 20° F water temperature drop, 60° F entering-air temperature. NOTES: 1. Maximum operating limits for heating coils: 20 psig at 260 F. 2. Leaving db = ent db (F) + 3. See Heating Correction Factors table. Capacity (Btuh) 1.1 x cfm UNIT SIZE 40RUA 07 40RUA/S 08 40RUS 08 40RUA/S 12 40RUA/S 14 40RUA/S 16 Water Temp Drop (F) 10 20 30 Steam Pressure (psig) 0 2 5 STEAM COIL Entering-Air Temp (F) 40 50 60 70 1.06 0.98 0.91 0.85 1.09 1.02 0.95 0.89 1.13 1.06 1.00 0.93 2-ROW HOT WATER COIL† Water Cap. Ldb Flow PD (L/s) Cap. Ldb 850 1150 1450 1000 1400 1800 1000 1400 1800 1450 1900 2350 1750 2350 2950 43 53 62 48 59 71 48 59 71 62 72 82 108 122 136 57 53 51 55 50 47 55 50 47 50 46 44 66 58 53 46 53 61 50 60 70 50 60 70 88 90 93 106 120 134 59 53 50 56 50 47 56 50 47 65 54 48 65 57 52 1.0 1.2 1.3 1.1 1.3 1.5 1.1 1.3 1.5 1.9 2.0 2.0 2.3 2.6 2.9 10.2 12.8 16.0 11.5 15.3 19.5 11.5 15.3 19.5 15.0 24.7 24.5 12.4 15.2 17.9 2100 2800 3500 117 129 140 61 53 48 120 137 154 62 55 51 2.6 3.0 3.3 13.3 16.2 19.5 LEGEND: Cap. --- Capacity (Btuh in thousands) Ldb --- Leaving Air Dry Bulb Temp (C) PD . --- Pressure Drop (ft water) * Based on 34.5 kPag steam, 15.6° C entering-air temperature. All steam coils are non-freeze type. † Based on 93.3° C entering water temperature, 11.1° C water temperature drop, 15.6° C entering-air temperature. NOTES: 1. Maximum operating limits for heating coils: 138 kPag at 126.7 C. 2. Leaving db = ent db (C) 3. See Heating Correction Factors table. HEATING CORRECTION FACTORS — U.S. HOT WATER COIL Ent Water Entering-Air Temp (F) Temp 40 50 60 70 (F) 140 0.72 0.64 0.57 0.49 160 0.89 0.81 0.74 0.66 180 1.06 0.98 0.90 0.83 200 1.22 1.15 1.07 1.00 220 1.39 1.32 1.24 1.17 140 0.64 0.57 0.49 0.41 160 0.81 0.74 0.66 0.58 180 0.98 0.91 0.83 0.75 200 1.15 1.08 1.00 0.93 220 1.32 1.25 1.17 1.10 140 0.56 0.49 0.41 0.33 160 0.74 0.66 0.58 0.51 180 0.91 0.83 0.76 0.68 200 1.08 1.00 0.93 0.85 220 1.25 1.18 1.10 1.03 AIRFLOW (L/s) 1-ROW STEAM* + Capacity (kW) 1.23 x 10 --- 3 x L/s HEATING CORRECTION FACTORS — SI Water Temp Drop (C) 80 0.41 0.58 0.75 0.92 1.09 0.33 0.51 0.68 0.85 1.02 0.24 0.43 0.60 0.78 0.95 5 11 16 Steam Pressure (kPag) 0 14 35 80 0.78 0.82 0.87 NOTE: Multiply capacity given in the Hydronic Heating Capacities table by the correction factor for conditions at which unit is actually operating. Correct leaving-air temperature using formula in Note 2 of Hydronic Heating Capacities table. HOT WATER COIL Ent Water Entering-Air Temp (C) Temp 4 10 16 20 (C) 60 0.72 0.64 0.55 0.50 70 0.87 0.79 0.71 0.65 80 1.02 0.94 0.86 0.80 90 1.17 1.09 1.01 0.95 100 1.32 1.24 1.16 1.10 60 0.65 0.56 0.48 0.42 70 0.80 0.72 0.63 0.58 80 0.95 0.87 0.79 0.73 90 1.10 1.02 0.94 0.89 100 1.26 1.18 1.09 1.04 60 0.56 0.48 0.39 0.33 70 0.72 0.63 0.55 0.49 80 0.87 0.79 0.70 0.65 90 1.02 0.94 0.86 0.81 100 1.18 1.10 1.02 0.97 STEAM COIL Entering-Air Temp (C) 4 10 16 20 1.07 0.99 0.91 0.86 1.10 1.02 0.95 0.90 1.14 1.07 0.99 0.95 25 0.43 0.58 0.73 0.89 1.04 0.35 0.51 0.66 0.82 0.97 0.26 0.42 0.58 0.74 0.90 25 0.80 0.84 0.89 NOTE: Multiply capacity given in the Hydronic Heating Capacities table by the correction factor for conditions at which unit is actually operating. Correct leaving-air temperature using formula in Note 2 of Hydronic Heating Capacities table. 22 PERFORMANCE DATA (cont.) FAN PERFORMANCE DATA — 40RUA 208/230 ---1 ---60 0.0-1.2 in. wg ESP — 60 Hz, U.S. AIRFLOW (Cfm) 1,800 2,100 2,400 2,700 3,000 2,250 2,600 3,000 3,400 3,750 07 08 0.0 Rpm Bhp 419 0.21 471 0.31 524 0.44 578 0.61 633 0.81 290 0.10 349 0.19 579 0.70 646 0.99 705 1.31 EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 Rpm Bhp Rpm Bhp Rpm Bhp 564 0.37 649 0.49 727 0.63 602 0.49 679 0.62 751 0.77 645 0.64 715 0.79 781 0.94 690 0.84 755 0.99 816 1.15 738 1.07 799 1.24 856 1.41 594 0.51 669 0.65 739 0.79 640 0.70 709 0.84 773 1.00 695 0.96 759 1.12 818 1.30 752 1.29 813 1.48 869 1.67 804 1.63 862 1.85 915 2.05 0.2 Rpm Bhp 471 0.26 519 0.37 568 0.51 619 0.69 671 0.90 510 0.39 561 0.55 621 0.79 683 1.09 739 1.42 Plain type --- Standard Motor and fan drive . --- Medium static option; std motor, medium static drive BOLD --- Standard motor & field --- supplied drive required . BOLD ----- 1.0 Rpm 797 819 844 875 910 806 834 874 920 964 1.2 Bhp 0.77 0.92 1.11 1.33 1.60 0.95 1.16 1.47 1.86 2.26 Rpm 862 882 905 932 963 870 893 928 970 1011 Bhp 0.92 1.09 1.28 1.51 1.79 1.12 1.34 1.66 2.06 2.48 High static motor & drive High static motor & field --- supplied drive 40RU 40RUA UNIT SIZE 4-Row Coil FAN PERFORMANCE DATA — 40RUA 208/230 ---1 ---60 1.4-2.4 in. wg ESP — 60 Hz, U.S. 40RUA UNIT SIZE 4-Row Coil AIRFLOW (Cfm) 1,800 2,100 2,400 2,700 3,000 2,250 2,600 3,000 3,400 3,750 07 08 1.4 Rpm 921 942 963 987 1015 930 950 980 1018 1057 1.6 Bhp 1.07 1.26 1.47 1.71 1.99 1.29 1.53 1.86 2.26 2.69 Rpm 975 997 1017 1039 1065 986 1005 1031 1065 1101 EXTERNAL STATIC PRESSURE (in. wg) 1.8 2.0 2.2 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 1.23 1026 1.39 1074 1.55 1120 1.72 1.43 1048 1.61 1097 1.79 1143 1.97 1.66 1069 1.85 1118 2.05 1164 2.25 1.91 1090 2.12 1138 2.33 1185 2.55 2.20 1113 2.42 1161 2.65 — — 1.47 1039 1.65 1089 1.84 1136 2.03 1.72 1057 1.92 1107 2.13 1154 2.33 2.06 1081 2.27 1129 2.49 1175 2.72 2.48 1111 2.70 1156 2.93 — — 2.92 1144 3.15 1186 3.39 — — Plain type --- Standard Motor and fan drive . --- Medium static option; std motor, medium static drive BOLD --- Standard motor & field --- supplied drive required . BOLD ----- 2.4 Rpm Bhp 1164 1.90 1186 2.16 — — — — — — 1181 2.22 — — — — — — — — High static motor & drive High static motor & field --- supplied drive FAN PERFORMANCE DATA — 40RUS — 0.0-1.2 in. wg ESP — 60 Hz, U.S. 40RUS UNIT SIZE 4---Row Coil AIRFLOW (Cfm) 010 2,550 2,975 3,400 3,825 4,250 0.0 Rpm Bhp 396 0.42 462 0.60 527 0.80 593 1.05 659 1.33 0.2 Rpm Bhp 502 0.54 556 0.72 612 0.93 670 1.18 729 1.47 EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 Rpm Bhp Rpm Bhp Rpm Bhp 586 0.65 658 0.76 722 0.87 634 0.84 701 0.95 762 1.06 684 1.06 748 1.18 806 1.30 737 1.31 797 1.44 852 1.56 791 1.60 848 1.73 901 1.86 1.0 Rpm 780 818 860 904 950 1.2 Bhp 0.97 1.18 1.41 1.68 1.98 Rpm 833 870 910 952 997 FAN PERFORMANCE DATA — 40RUS — 1.4-2.4 in. wg ESP — 60 Hz, U.S. 40RUS UNIT SIZE 4---Row Coil AIRFLOW (Cfm) 010 2,550 2,975 3,400 3,825 4,250 1.4 Rpm Bhp 884 1.18 919 1.40 957 1.64 998 1.92 1041 2.23 EXTERNAL STATIC PRESSURE (in. wg) 1.6 1.8 2.0 2.2 Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 931 1.29 975 1.40 1018 1.50 1059 1.61 965 1.51 1009 1.62 1050 1.73 1090 1.84 1002 1.76 1044 1.87 1085 1.98 1124 2.10 1041 2.04 1082 2.16 1122 2.27 1160 2.39 1083 2.35 1123 2.48 1161 2.60 1199 2.72 Plain type --- Standard Motor and fan drive . --- Medium static option; std motor, medium static drive BOLD --- Standard motor & field --- supplied drive required . BOLD 23 ----- 2.4 Rpm — — — — — Bhp — — — — — High static motor & drive High static motor & field --- supplied drive Bhp 1.08 1.29 1.53 1.80 2.11 FAN PERFORMANCE DATA — 40RU 208/230 ---3 ---60 & 460 ---3 ---60 0.0-1.2 in. wg ESP — 60 Hz, U.S. UNIT 4ORUA 4---Row Coil 07 40RU 08 12 14 16 AIRFLOW (Cfm) 0.0 Rpm Bhp 419 0.21 471 0.31 524 0.44 578 0.61 633 0.81 290 0.10 349 0.19 579 0.70 646 0.99 705 1.31 421 0.35 626 0.98 706 1.42 786 1.99 867 2.70 410 0.43 455 0.62 514 0.92 575 1.32 624 1.71 437 0.61 499 0.95 555 1.34 620 1.91 677 2.52 1,800 2,100 2,400 2,700 3,000 2,250 2,600 3,000 3,400 3,750 3,000 3,500 4,000 4,500 5,000 3,750 4,300 5,000 5,700 6,250 4,500 5,300 6,000 6,800 7,500 0.2 Rpm Bhp 471 0.26 519 0.37 568 0.51 619 0.69 671 0.90 510 0.39 561 0.55 621 0.79 683 1.09 739 1.42 592 0.73 664 1.08 738 1.54 815 2.12 893 2.84 467 0.55 504 0.74 556 1.06 612 1.47 657 1.87 483 0.72 538 1.07 590 1.48 651 2.06 706 2.69 EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 Rpm Bhp Rpm Bhp Rpm Bhp 564 0.37 649 0.49 727 0.63 602 0.49 679 0.62 751 0.77 645 0.64 715 0.79 781 0.94 690 0.84 755 0.99 816 1.15 738 1.07 799 1.24 856 1.41 594 0.51 669 0.65 739 0.79 640 0.70 709 0.84 773 1.00 695 0.96 759 1.12 818 1.30 752 1.29 813 1.48 869 1.67 804 1.63 862 1.85 915 2.05 670 0.90 737 1.06 797 1.23 735 1.28 798 1.48 855 1.67 803 1.77 862 2.00 917 2.23 873 2.39 929 2.65 980 2.90 946 3.14 997 3.43 1046 3.72 567 0.83 649 1.12 721 1.41 599 1.05 679 1.38 748 1.70 641 1.39 718 1.76 786 2.14 686 1.82 759 2.23 825 2.66 725 2.24 793 2.66 856 3.12 576 1.01 660 1.35 732 1.69 617 1.37 696 1.74 767 2.13 659 1.79 730 2.17 798 2.59 712 2.39 774 2.78 836 3.22 761 3.04 817 3.44 873 3.89 Plain type --- Standard Motor and fan drive . --- Medium static option; std motor, medium static drive BOLD --- Standard motor & field --- supplied drive required . BOLD ----- 1.0 Rpm 797 819 844 875 910 806 834 874 920 964 854 908 967 1028 1092 788 811 847 884 915 797 830 860 896 929 1.2 Bhp 0.77 0.92 1.11 1.33 1.60 0.95 1.16 1.47 1.86 2.26 1.41 1.87 2.45 3.16 4.00 1.72 2.04 2.52 3.09 3.59 2.03 2.53 3.04 3.71 4.39 Rpm 862 882 905 932 963 870 893 928 970 1011 908 958 1014 1073 1135 851 871 903 939 969 856 888 918 952 984 Bhp 0.92 1.09 1.28 1.51 1.79 1.12 1.34 1.66 2.06 2.48 1.59 2.07 2.67 3.41 4.28 2.05 2.39 2.91 3.52 4.06 2.38 2.94 3.49 4.21 4.93 High static motor & drive High static motor & field --- supplied drive FAN PERFORMANCE DATA — 40RU 208/230 ---3 ---60 & 460 ---3 ---60 1.4-2.4 in. wg ESP — 60 Hz, U.S. UNIT 4ORUA 4---Row Coil 07 08 12 14 16 AIRFLOW (Cfm) 1,800 2,100 2,400 2,700 3,000 2,250 2,600 3,000 3,400 3,750 3,000 3,500 4,000 4,500 5,000 3,750 4,300 5,000 5,700 6,250 4,500 5,300 6,000 6,800 7,500 1.4 Rpm 921 942 963 987 1015 930 950 980 1018 1057 961 1005 1058 1116 1176 912 928 956 990 1019 912 942 971 1005 1036 1.6 Bhp 1.07 1.26 1.47 1.71 1.99 1.29 1.53 1.86 2.26 2.69 1.78 2.27 2.90 3.66 4.56 2.39 2.75 3.30 3.96 4.54 2.75 3.34 3.95 4.72 5.48 Rpm 975 997 1017 1039 1065 986 1005 1031 1065 1101 1012 1052 1101 1157 — 971 982 1007 1039 1067 967 992 1020 1054 1084 EXTERNAL STATIC PRESSURE (in. wg) 1.8 2.0 2.2 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 1.23 1026 1.39 1074 1.55 1120 1.72 1.43 1048 1.61 1097 1.79 1143 1.97 1.66 1069 1.85 1118 2.05 1164 2.25 1.91 1090 2.12 1138 2.33 1185 2.55 2.20 1113 2.42 1161 2.65 — — 1.47 1039 1.65 1089 1.84 1136 2.03 1.72 1057 1.92 1107 2.13 1154 2.33 2.06 1081 2.27 1129 2.49 1175 2.72 2.48 1111 2.70 1156 2.93 — — 2.92 1144 3.15 1186 3.39 — — 1.98 1062 2.19 1111 2.41 1158 2.64 2.49 1098 2.71 1142 2.94 1186 3.18 3.13 1143 3.36 1184 3.60 — — 3.91 1196 4.16 — — — — — — — — — — — 2.76 1028 3.14 1083 3.54 1135 3.95 3.13 1036 3.53 1087 3.94 1138 4.37 3.71 1056 4.13 1104 4.56 1151 5.00 4.40 1086 4.85 1130 5.31 1174 5.78 5.02 1112 5.50 1156 5.99 1198 6.49 3.12 1019 3.52 1070 3.92 1120 4.35 3.76 1041 4.18 1088 4.61 1134 5.06 4.40 1067 4.86 1112 5.33 1156 5.81 5.23 1101 5.75 1145 6.27 1187 6.79 6.04 1131 6.61 1174 7.17 — — Plain type --- Standard Motor and fan drive . --- Medium static option; std motor, medium static drive BOLD --- Standard motor & field --- supplied drive required . BOLD 24 ----- 2.4 Rpm Bhp 1164 1.90 1186 2.16 — — — — — — 1181 2.22 — — — — — — — — — — — — — — — — — — 1185 4.36 1187 4.81 1196 5.46 — — — — 1168 4.79 1179 5.52 1198 6.29 — — — — High static motor & drive High static motor & field --- supplied drive FAN PERFORMANCE DATA — 40RU 575 ---3 ---60 0.0-1.2 in. wg ESP — 60 Hz, U.S. 07 08 012 14 16 AIRFLOW (Cfm) 1,800 2,100 2,400 2,700 3,000 2,250 2,600 3,000 3,400 3,750 3,000 3,500 4,000 4,500 5,000 3,750 4,300 5,000 5,700 6,250 4,500 5,300 6,000 6,800 7,500 0.0 Rpm Bhp 419 0.21 471 0.31 524 0.44 578 0.61 633 0.81 290 0.10 349 0.19 579 0.70 646 0.99 705 1.31 421 0.35 626 0.98 706 1.42 786 1.99 867 2.70 410 0.43 455 0.62 514 0.92 575 1.32 624 1.71 437 0.61 499 0.95 555 1.34 620 1.91 677 2.52 0.2 Rpm Bhp 471 0.26 519 0.37 568 0.51 619 0.69 671 0.90 510 0.39 561 0.55 621 0.79 683 1.09 739 1.42 592 0.73 664 1.08 738 1.54 815 2.12 893 2.84 467 0.55 504 0.74 556 1.06 612 1.47 657 1.87 483 0.72 538 1.07 590 1.48 651 2.06 706 2.69 EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 Rpm Bhp Rpm Bhp Rpm Bhp 564 0.37 649 0.49 727 0.63 602 0.49 679 0.62 751 0.77 645 0.64 715 0.79 781 0.94 690 0.84 755 0.99 816 1.15 738 1.07 799 1.24 856 1.41 594 0.51 669 0.65 739 0.79 640 0.70 709 0.84 773 1.00 695 0.96 759 1.12 818 1.30 752 1.29 813 1.48 869 1.67 804 1.63 862 1.85 915 2.05 670 0.90 737 1.06 797 1.23 735 1.28 798 1.48 855 1.67 803 1.77 862 2.00 917 2.23 873 2.39 929 2.65 980 2.90 946 3.14 997 3.43 1046 3.72 567 0.83 649 1.12 721 1.41 599 1.05 679 1.38 748 1.70 641 1.39 718 1.76 786 2.14 686 1.82 759 2.23 825 2.66 725 2.24 793 2.66 856 3.12 576 1.01 660 1.35 732 1.69 617 1.37 696 1.74 767 2.13 659 1.79 730 2.17 798 2.59 712 2.39 774 2.78 836 3.22 761 3.04 817 3.44 873 3.89 Plain type --- Standard Motor and fan drive . --- Medium static option; std motor, medium static drive BOLD --- Standard motor & field --- supplied drive required . BOLD ----- 1.0 Rpm 797 819 844 875 910 806 834 874 920 964 854 908 967 1028 1092 788 811 847 884 915 797 830 860 896 929 1.2 Bhp 0.77 0.92 1.11 1.33 1.60 0.95 1.16 1.47 1.86 2.26 1.41 1.87 2.45 3.16 4.00 1.72 2.04 2.52 3.09 3.59 2.03 2.53 3.04 3.71 4.39 Rpm 862 882 905 932 963 870 893 928 970 1011 908 958 1014 1073 1135 851 871 903 939 969 856 888 918 952 984 Bhp 0.92 1.09 1.28 1.51 1.79 1.12 1.34 1.66 2.06 2.48 1.59 2.07 2.67 3.41 4.28 2.05 2.39 2.91 3.52 4.06 2.38 2.94 3.49 4.21 4.93 High static motor & drive High static motor & field --- supplied drive FAN PERFORMANCE DATA — 40RU 575 ---3 ---60 1.4-2.4 in. wg ESP — 60 Hz, U.S. UNIT 4ORUA 4---Row Coil 07 08 12 14 16 AIRFLOW (Cfm) 1,800 2,100 2,400 2,700 3,000 2,250 2,600 3,000 3,400 3,750 3,000 3,500 4,000 4,500 5,000 3,750 4,300 5,000 5,700 6,250 4,500 5,300 6,000 6,800 7,500 1.4 Rpm 921 942 963 987 1015 930 950 980 1018 1057 961 1005 1058 1116 1176 912 928 956 990 1019 912 942 971 1005 1036 1.6 Bhp 1.07 1.26 1.47 1.71 1.99 1.29 1.53 1.86 2.26 2.69 1.78 2.27 2.90 3.66 4.56 2.39 2.75 3.30 3.96 4.54 2.75 3.34 3.95 4.72 5.48 Rpm 975 997 1017 1039 1065 986 1005 1031 1065 1101 1012 1052 1101 1157 — 971 982 1007 1039 1067 967 992 1020 1054 1084 EXTERNAL STATIC PRESSURE (in. wg) 1.8 2.0 2.2 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 1.23 1026 1.39 1074 1.55 1120 1.72 1.43 1048 1.61 1097 1.79 1143 1.97 1.66 1069 1.85 1118 2.05 1164 2.25 1.91 1090 2.12 1138 2.33 1185 2.55 2.20 1113 2.42 1161 2.65 — — 1.47 1039 1.65 1089 1.84 1136 2.03 1.72 1057 1.92 1107 2.13 1154 2.33 2.06 1081 2.27 1129 2.49 1175 2.72 2.48 1111 2.70 1156 2.93 — — 2.92 1144 3.15 1186 3.39 — — 1.98 1062 2.19 1111 2.41 1158 2.64 2.49 1098 2.71 1142 2.94 1186 3.18 3.13 1143 3.36 1184 3.60 — — 3.91 1196 4.16 — — — — — — — — — — — 2.76 1028 3.14 1083 3.54 1135 3.95 3.13 1036 3.53 1087 3.94 1138 4.37 3.71 1056 4.13 1104 4.56 1151 5.00 4.40 1086 4.85 1130 5.31 1174 5.78 5.02 1112 5.50 1156 5.99 1198 6.49 3.12 1019 3.52 1070 3.92 1120 4.35 3.76 1041 4.18 1088 4.61 1134 5.06 4.40 1067 4.86 1112 5.33 1156 5.81 5.23 1101 5.75 1145 6.27 1187 6.79 6.04 1131 6.61 1174 7.17 — — Plain type --- Standard Motor and fan drive . --- Medium static option; std motor, medium static drive BOLD --- Standard motor & field --- supplied drive required . BOLD 25 ----- 2.4 Rpm Bhp 1164 1.90 1186 2.16 — — — — — — 1181 2.22 — — — — — — — — — — — — — — — — — — 1185 4.36 1187 4.81 1196 5.46 — — — — 1168 4.79 1179 5.52 1198 6.29 — — — — High static motor & drive High static motor & field --- supplied drive 40RU UNIT 4ORUA 4---Row Coil FAN PERFORMANCE DATA — 40RU 230 ---3 ---60 & 460 ---3 ---60 0.0-1.2 in. wg ESP — 60 Hz, U.S. UNIT 4ORUA 4---Row Coil 07 40RU 08 12 14 16 AIRFLOW (Cfm) 1,800 2,100 2,400 2,700 3,000 2,250 2,600 3,000 3,400 3,750 3,000 3,500 4,000 4,500 5,000 3,750 4,300 5,000 5,700 6,250 4,500 5,300 6,000 6,800 7,500 0.0 Rpm Bhp 419 0.21 471 0.31 524 0.44 578 0.61 633 0.81 290 0.10 349 0.19 579 0.70 646 0.99 705 1.31 421 0.35 626 0.98 706 1.42 786 1.99 867 2.70 410 0.43 455 0.62 514 0.92 575 1.32 624 1.71 437 0.61 499 0.95 555 1.34 620 1.91 677 2.52 0.2 Rpm Bhp 471 0.26 519 0.37 568 0.51 619 0.69 671 0.90 510 0.39 561 0.55 621 0.79 683 1.09 739 1.42 592 0.73 664 1.08 738 1.54 815 2.12 893 2.84 467 0.55 504 0.74 556 1.06 612 1.47 657 1.87 483 0.72 538 1.07 590 1.48 651 2.06 706 2.69 EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 Rpm Bhp Rpm Bhp Rpm Bhp 564 0.37 649 0.49 727 0.63 602 0.49 679 0.62 751 0.77 645 0.64 715 0.79 781 0.94 690 0.84 755 0.99 816 1.15 738 1.07 799 1.24 856 1.41 594 0.51 669 0.65 739 0.79 640 0.70 709 0.84 773 1.00 695 0.96 759 1.12 818 1.30 752 1.29 813 1.48 869 1.67 804 1.63 862 1.85 915 2.05 670 0.90 737 1.06 797 1.23 735 1.28 798 1.48 855 1.67 803 1.77 862 2.00 917 2.23 873 2.39 929 2.65 980 2.90 946 3.14 997 3.43 1046 3.72 567 0.83 649 1.12 721 1.41 599 1.05 679 1.38 748 1.70 641 1.39 718 1.76 786 2.14 686 1.82 759 2.23 825 2.66 725 2.24 793 2.66 856 3.12 576 1.01 660 1.35 732 1.69 617 1.37 696 1.74 767 2.13 659 1.79 730 2.17 798 2.59 712 2.39 774 2.78 836 3.22 761 3.04 817 3.44 873 3.89 Plain type --- Standard Motor and fan drive . --- Medium static option; std motor, medium static drive BOLD --- Standard motor & field --- supplied drive required . BOLD ----- 1.0 Rpm 797 819 844 875 910 806 834 874 920 964 854 908 967 1028 1092 788 811 847 884 915 797 830 860 896 929 1.2 Bhp 0.77 0.92 1.11 1.33 1.60 0.95 1.16 1.47 1.86 2.26 1.41 1.87 2.45 3.16 4.00 1.72 2.04 2.52 3.09 3.59 2.03 2.53 3.04 3.71 4.39 Rpm 862 882 905 932 963 870 893 928 970 1011 908 958 1014 1073 1135 851 871 903 939 969 856 888 918 952 984 Bhp 0.92 1.09 1.28 1.51 1.79 1.12 1.34 1.66 2.06 2.48 1.59 2.07 2.67 3.41 4.28 2.05 2.39 2.91 3.52 4.06 2.38 2.94 3.49 4.21 4.93 High static motor & drive High static motor & field --- supplied drive FAN PERFORMANCE DATA — 40RU 230 ---3 ---60 & 460 ---3 ---60 1.4-2.4 in. wg ESP — 60 Hz, U.S. UNIT 4ORUA 4---Row Coil 07 08 12 14 16 AIRFLOW (Cfm) 1,800 2,100 2,400 2,700 3,000 2,250 2,600 3,000 3,400 3,750 3,000 3,500 4,000 4,500 5,000 3,750 4,300 5,000 5,700 6,250 4,500 5,300 6,000 6,800 7,500 1.4 Rpm 921 942 963 987 1015 930 950 980 1018 1057 961 1005 1058 1116 1176 912 928 956 990 1019 912 942 971 1005 1036 1.6 Bhp 1.07 1.26 1.47 1.71 1.99 1.29 1.53 1.86 2.26 2.69 1.78 2.27 2.90 3.66 4.56 2.39 2.75 3.30 3.96 4.54 2.75 3.34 3.95 4.72 5.48 Rpm 975 997 1017 1039 1065 986 1005 1031 1065 1101 1012 1052 1101 1157 — 971 982 1007 1039 1067 967 992 1020 1054 1084 EXTERNAL STATIC PRESSURE (in. wg) 1.8 2.0 2.2 Bhp Rpm Bhp Rpm Bhp Rpm Bhp 1.23 1026 1.39 1074 1.55 1120 1.72 1.43 1048 1.61 1097 1.79 1143 1.97 1.66 1069 1.85 1118 2.05 1164 2.25 1.91 1090 2.12 1138 2.33 1185 2.55 2.20 1113 2.42 1161 2.65 — — 1.47 1039 1.65 1089 1.84 1136 2.03 1.72 1057 1.92 1107 2.13 1154 2.33 2.06 1081 2.27 1129 2.49 1175 2.72 2.48 1111 2.70 1156 2.93 — — 2.92 1144 3.15 1186 3.39 — — 1.98 1062 2.19 1111 2.41 1158 2.64 2.49 1098 2.71 1142 2.94 1186 3.18 3.13 1143 3.36 1184 3.60 — — 3.91 1196 4.16 — — — — — — — — — — — 2.76 1028 3.14 1083 3.54 1135 3.95 3.13 1036 3.53 1087 3.94 1138 4.37 3.71 1056 4.13 1104 4.56 1151 5.00 4.40 1086 4.85 1130 5.31 1174 5.78 5.02 1112 5.50 1156 5.99 1198 6.49 3.12 1019 3.52 1070 3.92 1120 4.35 3.76 1041 4.18 1088 4.61 1134 5.06 4.40 1067 4.86 1112 5.33 1156 5.81 5.23 1101 5.75 1145 6.27 1187 6.79 6.04 1131 6.61 1174 7.17 — — Plain type --- Standard Motor and fan drive . --- Medium static option; std motor, medium static drive BOLD --- Standard motor & field --- supplied drive required . BOLD 26 ----- 2.4 Rpm Bhp 1164 1.90 1186 2.16 — — — — — — 1181 2.22 — — — — — — — — — — — — — — — — — — 1185 4.36 1187 4.81 1196 5.46 — — — — 1168 4.79 1179 5.52 1198 6.29 — — — — High static motor & drive High static motor & field --- supplied drive PERFORMANCE DATA (cont.) LEGEND AND NOTES FOR STANDARD AND HIGH- CAPACITY COIL FAN PERFORMANCE DATA TABLES (U.S.) LEGEND: Bhp --- Brake Horsepower Input to Fan ESP --- External Static Pressure NOTES: 1. Maximum allowable fan speed is 1200 rpm for all sizes. 2. Fan performance is based on deductions for wet coil, clean 2-in. filters, and unit casing. See table below for factory-supplied filter pressure drop. MODEL 40RUA 40RMS SIZE CFM dB(A) 07 08 12 14 16 08 10 12 14 16 2,400 3,000 4,000 5,000 6,000 3,000 3,400 4,000 5,000 6,000 86.3 88.3 91.6 91.1 92.7 88.3 89.8 91.6 91.1 92.7 63 93.2 95.3 98.6 97.3 98.9 95.3 96.7 98.6 97.3 98.9 LEGEND: ASHRAE --- American Society of Heating, Refrigerating and Air Conditioning, Inc. HVAC --- Heating, Ventilation and Air Conditioning 125 89.2 91.3 94.6 93.3 94.9 91.3 92.7 94.6 93.3 94.9 OCTAVE BAND CENTER FREQUENCY (Hz) 250 500 1000 2000 85.2 84.2 80.2 78.2 87.3 86.3 82.3 80.3 90.6 89.6 85.6 83.6 89.3 90.3 84.3 82.3 90.9 91.9 85.9 83.9 87.3 86.3 82.3 80.3 88.7 87.7 83.7 81.7 90.6 89.6 85.6 83.6 89.3 90.3 84.3 82.3 90.9 91.9 85.9 83.9 NOTES: 1. The above estimated sound power levels are based upon the ASHRAE calculation approach from the ASHRAE 1987 HVAC Systems and Applications handbook, Chapter 52. 2. Since this data is calculated, these sound power levels may be different than the actual sound power levels. 3. The acoustic center of the unit is located at the geometric center of the unit. FACTORY-SUPPLIED FILTER PRESSURE DROP — U.S. SIZE UNIT 07 40RUA 08 40RUA/S 10* 40RUS 12 40RUA/S 14 40RUA/S 16 40RUA/S * Data not available. AIRFLOW (Cfm) 1,800 2,400 3,000 2,250 3,000 3,750 --3,000 4,000 5,000 3,750 5,000 6,250 4,500 6,000 7,500 4000 74.2 76.3 79.6 78.3 79.9 76.3 77.7 79.6 78.3 79.9 FACTORY-SUPPLIED FILTER PRESSURE DROP — SI PRESSURE DROP (in. wg) 0.05 0.08 0.11 0.07 0.11 0.15 --0.11 0.17 0.23 0.06 0.10 0.13 0.08 0.12 0.17 SIZE UNIT 07 40RUA 08 40RUA/S 10* 40RUS 12 40RUA/S 14 40RUA/S 16 40RUA/S * Data not available. 27 AIRFLOW (L/s) 850 1150 1450 1000 1400 1800 --1450 1900 2350 1750 2350 2950 2100 2800 3500 PRESSURE DROP (Pa) 13 20 28 17 27 38 --28 42 56 15 24 33 20 30 42 40RU DUCT SOUND POWER LEVELS (Lw) PERFORMANCE DATA (cont.) ACCESSORY PLENUM AIR THROW DATA — U.S. (Ft) AIRFLOW (Cfm) UNIT 40RU 40RUA 07 40RUA/S 08 40RUS 10 40RUA/S 12 40RUA/S 14 40RUA/S 16 ACCESSORY PLENUM AIR THROW DATA — SI(m) VANE DEFLECTION Straight 21∫° 45° 2,400 39 33 24 3,000 45 38 28 3,400 49 41 30 4,000 55 46 33 5,000 45 38 28 6,000 50 43 31 NOTE: Throw distances shown are for 75 fpm terminal velocity. Use the following multipliers to determine throw values for other terminal velocities. TERMINAL VELOCITY (Fpm) 50 100 150 AIRFLOW (L/s) UNIT 40RUA 07 40RUA/S 08 40RUS 10 40RUA/S 12 40RUA/S 14 40RUA/S 16 VANE DEFLECTION Straight 21∫° 45° 1150 11.71 9.91 7.20 1400 13.87 11.71 8.63 1600 14.98 12.53 9.17 1900 16.65 13.93 9.99 2350 13.77 11.63 8.57 2800 15.41 13.25 9.55 NOTE: Throw distances shown are for 0.381 m/sec terminal velocity. Use the following multipliers to determine throw values for other terminal velocities. TERMINAL VELOCITY (m/sec) 0.254 0.508 0.762 THROW FACTOR X 1.50 X 0.75 X 0.50 28 THROW FACTOR X 1.50 X 0.75 X 0.50 PERFORMANCE DATA (cont.) ACCESSORY PRESSURE DROP — U.S. (in. wg) 40RUA 07 40RUA/S 08 40RUS 10 40RUA/S 12 40RUA/S 14 40RUA/S 16 DISCHARGE PLENUM 0.06 0.10 0.14 0.09 0.14 0.21 0.11 0.17 0.24 0.14 0.22 0.32 0.07 0.12 0.17 0.10 0.16 0.23 AIRFLOW (L/s) 850 1150 1450 1000 1400 1800 1200 1600 2000 1450 1900 2350 1750 2350 2950 2100 2800 3500 DISCHARGE PLENUM 15 25 36 20 34 51 26 42 61 36 56 79 18 29 43 24 39 56 RETURN AIR GRILLE 0.01 0.01 0.02 0.01 0.02 0.03 0.02 0.03 0.04 0.02 0.04 0.06 0.01 0.02 0.02 0.01 0.02 0.03 Hot Water 0.10 0.16 0.23 0.15 0.23 0.35 0.18 0.28 0.41 0.23 0.37 0.53 0.11 0.17 0.25 0.15 0.23 0.33 HEATING COILS Steam 0.10 0.16 0.23 0.15 0.23 0.35 0.18 0.28 0.41 0.23 0.37 0.53 0.11 0.17 0.25 0.15 0.23 0.33 Electric 0.04 0.06 0.10 0.06 0.10 0.15 0.07 0.12 0.19 0.10 0.17 0.26 0.04 0.07 0.11 0.06 0.10 0.15 ECONOMIZER 0.05 0.07 0.09 0.06 0.09 0.15 0.07 0.13 0.19 0.09 0.17 0.28 0.05 0.07 0.11 0.06 0.09 0.15 ACCESSORY PRESSURE DROP — SI (Pa) UNIT 40RUA 07 40RUA/S 08 40RUS 10 40RUA/S 12 40RUA/S 14 40RUA/S 16 RETURN AIR GRILLE 2 3 5 2 5 8 5 7 10 5 10 15 2 5 5 2 5 7 Hot Water 25 41 60 33 57 85 44 70 101 60 93 132 26 43 62 36 57 82 29 HEATING COILS Steam 25 41 60 33 57 85 44 70 101 60 93 132 26 43 62 36 57 82 Electric 9 16 26 12 24 39 18 31 48 26 43 65 10 17 26 14 24 37 ECONOMIZER 12 18 23 13 22 39 17 32 47 23 43 69 12 17 27 15 22 37 40RU UNIT AIRFLOW (Cfm) 1,800 2,400 3,000 2,250 3,000 3,750 2,550 3,400 4,250 3,000 4,000 5,000 3,750 5,000 6,250 4,500 6,000 7,500 ELECTRICAL DATA STANDARD MOTORS UNIT 40RUA 07 40RUA/S 08 40RU 40RUS 10 40RUA/S 12 40RUA/S 14 40RUA/S 16 FAN MOTOR V-PH-Hz VOLTAGE LIMITS Hp (kW) FLA 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 187-253 187-253 414-506 518-632 187-253 187-253 414-506 518-632 187-253 187-253 414-506 518-632 187-253 414-506 518-632 187-253 414-506 518-632 187-253 414-506 518-632 1.3 (0.97) 2.4 (1.79) 2.4 (1.79) 1.0 (0.75) 2.4 (1.79) 2.4 (1.79) 2.4 (1.79) 2.0 (1.49) 2.4 (1.79) 2.4 (1.79) 2.4 (1.79) 2.0 (1.49) 2.4 (1.79) 2.4 (1.79) 2.0 (1.49) 2.4 (1.79) 2.4 (1.79) 3.0 (2.24) 3.7 (2.76) 3.7 (2.76) 3.0 (2.24) 7.6 5.8 2.6 1.4 11.0 5.8 2.6 2.4 11.0 5.2 2.6 2.3 5.8 2.6 2.4 5.8 2.6 3.8 10.6 4.8 3.8 LEGEND FLA — Full Load Amps MOCP — Maximum Overcurrent Protection * Motors are designed for satisfactory operation within 10% of nominal voltages shown. Voltages should not exceed the limits shown in the Voltage Limits column. NOTES: 1. Minimum circuit amps (MCA) and MOCP values are calculated in accordance with NEC (National Electrical Code) (U.S.A. standard), Article 440. 2. Motor FLA values are established in accordance with UL (Underwriters’ Laboratories) Standard 1995 (U.S.A. standard). 3. Indoor fan motors 5 hp and larger meet the minimum efficiency requirements as established by the Energy Policy Act of 1992 (EPACT) effective October 24, 1997. 4. Unbalanced 3--- Phase Supply Voltage Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percentage of voltage imbalance. % Voltage Imbalance = 100 x max voltage deviation from average voltage average voltage POWER SUPPLY Minimum Circuit MOCP Amps 9.5 15 7.5 15 3.3 15 1.7 15 13.8 20 6.5 15 3.3 15 3.0 15 13.8 20 6.5 15 3.3 15 2.9 15 7.3 15 3.3 15 3.0 15 7.5 15 3.3 15 4.8 15 13.3 20 6.0 15 4.8 15 Example: Supply voltage is 230-3-60 AB = 224 v BC = 231 v AC = 226 v Average Voltage = = (224 + 231 + 226) 3 = 681 3 227 Determine maximum deviation from average voltage. (AB) 227 – 224 = 3 v (BC) 231 – 227 = 4 v (AC) 227 – 226 = 1 v Maximum deviation is 4 v. Determine percent of voltage imbalance. % Voltage Imbalance = 100 x 4 227 = 1.76% This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%. IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately. 30 ELECTRICAL DATA (cont.) UNIT 40RUA 07 40RUA/S 08 40RUS 10 40RUA/S 12 40RUA/S 14 40RUA/S 16 FAN MOTOR V-PH-Hz VOLTAGE LIMITS Hp (kW) FLA 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-1-60 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 208/230-3-60 460-3-60 575-3-60 187-253 187-253 414-506 518-632 187-253 187-253 414-506 518-632 187-253 187-253 414-506 518-632 187-253 414-506 518-632 187-253 414-506 518-632 187-253 414-506 518-632 2.4 (1.79) 2.9 (2.16) 2.9 (2.16) 2.0 (1.49) 2.4 (1.79) 2.9 (2.16) 2.9 (2.16) 3.0 (2.24) 2.4 (1.79) 2.9 (2.16) 2.9 (2.16) 2.0 (1.49) 3.7 (2.76) 3.7 (2.76) 3.0 (2.24) 3.7 (2.76) 3.7 (2.76) 5.0 (3.73) 5.0 (3.73) 5.0 (3.73) 5.0 (3.73) 11.0 7.5 3.4 2.4 11.0 7.5 3.4 3.8 11.0 7.5 3.4 2.3 10.6 4.8 3.8 10.6 4.8 5.1 14.6 6.4 5.1 LEGEND FLA — Full Load Amps MOCP — Maximum Overcurrent Protection * Motors are designed for satisfactory operation within 10% of nominal voltages shown. Voltages should not exceed the limits shown in the Voltage Limits column. NOTES: 1. Minimum circuit amps (MCA) and MOCP values are calculated in accordance with NEC (National Electrical Code) (U.S.A. standard), Article 440. 2. Motor FLA values are established in accordance with UL (Underwriters’ Laboratories) Standard 1995 (U.S.A. standard). 3. Indoor fan motors 5 hp and larger meet the minimum efficiency requirements as established by the Energy Policy Act of 1992 (EPACT) effective October 24, 1997. 4. Unbalanced 3--- Phase Supply Voltage Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percentage of voltage imbalance. % Voltage Imbalance = 100 x max voltage deviation from average voltage average voltage POWER SUPPLY Minimum Circuit MOCP Amps 13.8 20 9.4 15 4.3 15 3.0 15 13.8 20 9.4 15 4.3 15 4.8 15 13.8 20 9.4 15 4.3 15 2.9 15 13.3 20 6.0 15 4.8 15 13.3 20 6.0 15 6.4 15 18.3/16.0 30/25 8.0 15 6.4 15 Example: Supply voltage is 230-3-60 AB = 224 v BC = 231 v AC = 226 v Average Voltage = = (224 + 231 + 226) 3 = 681 3 227 Determine maximum deviation from average voltage. (AB) 227 – 224 = 3 v (BC) 231 – 227 = 4 v (AC) 227 – 226 = 1 v Maximum deviation is 4 v. Determine percent of voltage imbalance. % Voltage Imbalance = 100 x 4 227 = 1.76% This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%. IMPORTANT: If the supply voltage phase imbalance is more than 2%, contact your local electric utility company immediately. 31 40RU ALTERNATE MOTORS ELECTRICAL DATA (cont.) ELECTRIC HEATER DATA HEATER PART NO. CAELHEAT SIZE FAN MOTOR V-PH-Hz 208-3-60 001A00 40RU 240-3-60 002A00 480-3-60 003A00 575-3-60 208-3-60 40RUA/S 07--- 12 40RUS 08--- 12 004A00 240-3-60 005A00 480-3-60 006A00 575-3-60 208-3-60 007A00 240-3-60 Hp kW FLA 1.3† 2.4† 2.4 2.9 3.7 1.3† 2.4† 2.4 2.9 3.7 2.4 2.9 3.7 1.0 2.0 3.0 1.3† 2.4† 2.4 2.9 3.7 1.3† 2.4† 2.4 2.9 3.7 2.4 2.9 3.7 1.0 2.0 3.0 1.3† 2.4† 2.4 2.9 3.7 1.3† 2.4† 2.4 2.9 3.7 0.97 1.79 1.79 2.16 2.76 0.97 1.79 1.79 2.16 2.76 1.79 2.16 2.76 0.75 1.49 2.24 0.97 1.79 1.79 2.16 2.76 0.97 1.79 1.79 2.16 2.76 1.79 2.16 2.76 0.75 1.49 2.24 0.97 1.79 1.79 2.16 2.76 0.97 1.79 1.79 2.16 2.76 7.6 11.0 5.2 7.5 10.2 7.6 11.0 5.2 7.5 10.2 2.6 3.4 4.8 1.4 2.3 3.8 7.6 11.0 5.2 7.5 10.2 7.6 11.0 5.2 7.5 10.2 2.6 3.4 4.8 1.4 2.3 3.8 7.6 11.0 5.2 7.5 10.2 7.6 11.0 5.2 7.5 10.2 Nominal Capacity (kW) 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 15 15 15 15 15 15 15 15 15 15 LEGEND FLA Hp MCA MOCP — — — — 240 ACTUAL HEATER VOLTAGE 200 208 230 0.694 0.751 0.918 240 400 440 460 480 550 575 600 1 — — — — — — — 1 — — — — 0.915 1 1.089 480 — — — — 575 — — — — 0.694 0.84 0.918 — — — FLA 10.4 10.4 10.4 10.4 10.4 12.0 12.0 12.0 12.0 12.0 6.00 6.00 6.00 5.00 5.00 5.00 20.8 20.8 20.8 20.8 20.8 24.1 24.1 24.1 24.1 24.1 12.0 12.0 12.0 10.0 10.0 10.0 31.3 31.3 31.3 31.3 31.3 36.1 36.1 36.1 36.1 36.1 MCA* MOCP* 22.5 26.8 19.5 22.4 25.8 24.5 28.8 21.5 24.4 27.8 10.8 11.8 13.5 8.0 9.2 11.0 35.6 39.8 32.6 35.4 38.8 39.6 43.8 36.6 39.4 42.8 18.3 19.3 21.0 14.3 15.4 17.3 48.6 52.9 45.6 48.5 51.9 54.6 58.9 51.6 54.5 57.9 25 35 20 25 30 25 35 25 25 30 15 15 15 15 15 15 40 40 35 40 40 40 50 40 40 50 20 20 25 15 20 20 50 60 50 50 60 60 60 60 60 60 2. The following equation converts kW of heat energy to Btuh: kW x 3,412 = Btuh. 3. Heater contactor coils are 24 v and require 8 va holding current. 4. Electric heaters are tested and ETL approved at maximum total external static pressure of 1.9 in. wg. 5. MCA and MOCP values apply to both standard and alternate factory-supplied motors. 6. Approximate shipping weight for CAELHEAT001A00-015A00 is 55 lb (25 kg) each. Approximate shipping weight for CAELHEAT016A00-027A00 is 60 lb (27 kg) each, and CAELHEAT028A00-039A00 is 75 lb (34 kg) each. Full Load Amps Horsepower Minimum Circuit Amps Maximum Overcurrent Protection (Amps) * Values shown are for single-point connection of electric heat accessory and air handler. † Single-phase motors. All other motors are 3-phase. NOTES: 1. Electrical resistance heaters are rated at 240 v, 480 v, or 575 v. To determine heater capacity (kW) at unit nameplate multiply the 240-v, 480-v, or 575-v capacity (kW) by the factor shown in the table below for the unit voltage. HEATER RATING VOLTAGE ELECTRIC HEATER(S) Actual Capacity (kW) Stage Stage Total 1 2 3.8 — 3.8 3.8 — 3.8 3.8 — 3.8 3.8 — 3.8 3.8 — 3.8 5.0 — 5.0 5.0 — 5.0 5.0 — 5.0 5.0 — 5.0 5.0 — 5.0 5.0 — 5.0 5.0 — 5.0 5.0 — 5.0 5.0 — 5.0 5.0 — 5.0 5.0 — 5.0 7.5 — 7.5 7.5 — 7.5 7.5 — 7.5 7.5 — 7.5 7.5 — 7.5 10.0 — 10.0 10.0 — 10.0 10.0 — 10.0 10.0 — 10.0 10.0 — 10.0 10.0 — 10.0 10.0 — 10.0 10.0 — 10.0 10.0 — 10.0 10.0 — 10.0 10.0 — 10.0 11.3 — 11.3 11.3 — 11.3 11.3 — 11.3 11.3 — 11.3 11.3 — 11.3 15.0 — 15.0 15.0 — 15.0 15.0 — 15.0 15.0 — 15.0 15.0 — 15.0 32 ELECTRICAL DATA (cont.) HEATER PART NO. CAELHEAT SIZE FAN MOTOR V-PH-Hz 008A00 480-3-60 009A00 575-3-60 208-3-60 40RUA 07--- 12 40RUS 08--- 12 010A00 240-3-60 011A00 480-3-60 012A00 575-3-60 208-3-60 013A00 40RUA 08,12 40RUS 08--- 12 240-3-60 014A00 480-3-60 015A00 575-3-60 Hp kW FLA 2.4 2.9 3.7 1.0 2.0 3.0 1.3† 2.4† 2.4 2.9 3.7 1.3† 2.4† 2.4 2.9 3.7 2.4 2.9 3.7 1.0 2.0 3.0 2.4† 2.4 2.9 3.7 2.4† 2.4 2.9 3.7 2.4 2.9 3.7 2.0 3.0 1.79 2.16 2.76 0.75 1.49 2.24 0.97 1.79 1.79 2.16 2.76 0.97 1.79 1.79 2.16 2.76 1.79 2.16 2.76 0.75 1.49 2.24 1.79 1.79 2.16 2.76 1.79 1.79 2.16 2.76 1.79 2.16 2.76 1.49 2.24 2.6 3.4 4.8 1.4 2.3 3.8 7.6 11.0 5.2 7.5 10.2 7.6 11.0 5.2 7.5 10.2 2.6 3.4 4.8 1.4 2.3 3.8 11.0 5.2 7.5 10.2 11.0 5.2 7.5 10.2 2.6 3.4 4.8 2.3 3.8 Nominal Capacity (kW) 15 15 15 15 15 15 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 35 35 35 35 35 35 35 35 35 35 35 35 35 LEGEND FLA Hp MCA MOCP — — — — 240 ACTUAL HEATER VOLTAGE 200 208 230 0.694 0.751 0.918 240 400 440 460 480 550 575 600 1 — — — — — — — 1 — — — — 0.915 1 1.089 480 — — — — 575 — — — — 0.694 0.84 0.918 — — — FLA 18.0 18.0 18.0 15.1 15.1 15.1 52.1 52.1 52.1 52.1 52.1 60.1 60.1 60.1 60.1 60.1 30.1 30.1 30.1 25.1 25.1 25.1 73.0 73.0 73.0 73.0 84.2 84.2 84.2 84.2 42.1 42.1 42.1 35.1 35.1 MCA* MOCP* 25.8 26.8 28.6 20.6 21.7 23.6 74.7 78.9 71.7 74.5 77.9 84.7 88.9 81.7 84.6 87.9 40.8 41.8 43.6 33.1 34.3 36.1 105.0 97.7 100.6 104.0 119.0 111.7 114.6 118.0 55.9 56.9 58.6 46.8 48.7 30 30 30 25 25 25 80 80 80 80 80 90 90 90 90 90 50 50 50 35 35 40 110 100 110 110 125 125 125 125 60 60 60 50 50 2. The following equation converts kW of heat energy to Btuh: kW x 3,412 = Btuh. 3. Heater contactor coils are 24 v and require 8 va holding current. 4. Electric heaters are tested and ETL approved at maximum total external static pressure of 1.9 in. wg. 5. MCA and MOCP values apply to both standard and alternate factory-supplied motors. 6. Approximate shipping weight for CAELHEAT001A00-015A00 is 55 lb (25 kg) each. Approximate shipping weight for CAELHEAT016A00-027A00 is 60 lb (27 kg) each, and CAELHEAT028A00-039A00 is 75 lb (34 kg) each. Full Load Amps Horsepower Minimum Circuit Amps Maximum Overcurrent Protection (Amps) * Values shown are for single-point connection of electric heat accessory and air handler. † Single-phase motors. All other motors are 3-phase. NOTES: 1. Electrical resistance heaters are rated at 240 v, 480 v, or 575 v. To determine heater capacity (kW) at unit nameplate multiply the 240-v, 480-v, or 575-v capacity (kW) by the factor shown in the table below for the unit voltage. HEATER RATING VOLTAGE ELECTRIC HEATER(S) Actual Capacity (kW) Stage Stage Total 1 2 15.0 — 15.0 15.0 — 15.0 15.0 — 15.0 15.0 — 15.0 15.0 — 15.0 15.0 — 15.0 11.3 7.5 18.8 11.3 7.5 18.8 11.3 7.5 18.8 11.3 7.5 18.8 11.3 7.5 18.8 15.0 10.0 25.0 15.0 10.0 25.0 15.0 10.0 25.0 15.0 10.0 25.0 15.0 10.0 25.0 15.0 10.0 25.0 15.0 10.0 25.0 15.0 10.0 25.0 15.0 10.0 25.0 15.0 10.0 25.0 15.0 10.0 25.0 15.0 11.3 26.3 15.0 11.3 26.3 15.0 11.3 26.3 15.0 11.3 26.3 20.0 15.0 35.0 20.0 15.0 35.0 20.0 15.0 35.0 20.0 15.0 35.0 20.0 15.0 35.0 20.0 15.0 35.0 20.0 15.0 35.0 20.0 15.0 35.0 20.0 15.0 35.0 33 40RU ELECTRIC HEATER DATA (cont) ELECTRICAL DATA (cont.) ELECTRIC HEATER DATA (cont) HEATER PART NO. CAELHEAT SIZE FAN MOTOR V-PH-Hz 208-3-60 016A00 40RU 240-3-60 017A00 480-3-60 018A00 575-3-60 208-3-60 019A00 40RUA 14,16 40RUS 14,16 020A00 021A00 240-3-60 480-3-60 575-3-60 208-3-60 022A00 240-3-60 023A00 480-3-60 024A00 575-3-60 Hp kW FLA 2.9 3.7 5.0 2.9 3.7 5.0 2.9 3.7 5.0 3.0 5.0 2.9 3.7 5.0 2.9 3.7 5.0 2.9 3.7 5.0 3.0 5.0 2.9 3.7 5.0 2.9 3.7 5.0 2.9 3.7 5.0 3.0 5.0 2.16 2.76 3.73 2.16 2.76 3.73 2.16 2.76 3.73 2.24 3.73 2.16 2.76 3.73 2.16 2.76 3.73 2.16 2.76 3.73 2.24 3.73 2.16 2.76 3.73 2.16 2.76 3.73 2.16 2.76 3.73 2.24 3.73 7.5 10.2 14.6 7.5 10.2 12.8 3.4 4.8 6.4 3.8 5.1 7.5 10.2 14.6 7.5 10.2 12.8 3.4 4.8 6.4 3.8 5.1 7.5 10.2 14.6 7.5 10.2 12.8 3.4 4.8 6.4 3.8 5.1 Nominal Capacity (kW) 10 10 10 10 10 10 10 10 10 10 10 20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 30 30 30 30 30 30 LEGEND FLA Hp MCA MOCP — — — — 240 ACTUAL HEATER VOLTAGE 200 208 230 0.694 0.751 0.918 240 400 440 460 480 550 575 600 1 — — — — — — — 1 — — — — 0.915 1 1.089 480 — — — — 575 — — — — 0.694 0.84 0.918 — — — FLA MCA* MOCP* 20.8 20.8 20.8 24.1 24.1 24.1 12.0 12.0 12.0 10.0 10.0 41.5 41.5 41.5 47.9 47.9 47.9 24.1 24.1 24.1 20.1 20.1 62.5 62.5 62.5 72.2 72.2 72.2 36.1 36.1 36.1 30.1 30.1 35.4 38.8 41.3 39.4 42.8 46.1 19.3 21.0 23.0 17.3 19.6 51.2 64.6 70.1 69.2 72.6 75.8 34.3 36.1 39.1 29.9 31.5 87.5 90.9 96.4 99.6 103.0 106.2 49.4 51.1 53.1 42.4 44.0 40 40 50 40 50 50 20 25 25 20 20 70 70 80 70 80 80 35 40 40 30 35 90 100 100 100 110 110 50 60 60 50 50 2. The following equation converts kW of heat energy to Btuh: kW x 3,412 = Btuh. 3. Heater contactor coils are 24 v and require 8 va holding current. 4. Electric heaters are tested and ETL approved at maximum total external static pressure of 1.9 in. wg. 5. MCA and MOCP values apply to both standard and alternate factory-supplied motors. 6. Approximate shipping weight for CAELHEAT001A00-015A00 is 55 lb (25 kg) each. Approximate shipping weight for CAELHEAT016A00-027A00 is 60 lb (27 kg) each, and CAELHEAT028A00-039A00 is 75 lb (34 kg) each. Full Load Amps Horsepower Minimum Circuit Amps Maximum Overcurrent Protection (Amps) * Values shown are for single-point connection of electric heat accessory and air handler. † Single-phase motors. All other motors are 3-phase. NOTES: 1. Electrical resistance heaters are rated at 240 v, 480 v, or 575 v. To determine heater capacity (kW) at unit nameplate multiply the 240-v, 480-v, or 575-v capacity (kW) by the factor shown in the table below for the unit voltage. HEATER RATING VOLTAGE ELECTRIC HEATER(S) Actual Capacity (kW) Stage Stage Total 1 2 7.5 — 7.5 7.5 — 7.5 7.5 — 7.5 10.0 — 10.0 10.0 — 10.0 10.0 — 10.0 10.0 — 10.0 10.0 — 10.0 10.0 — 10.0 10.0 — 10.0 10.0 — 10.0 14.9 — 14.9 14.9 — 14.9 14.9 — 14.9 19.9 — 19.9 19.9 — 19.9 19.9 — 19.9 20.0 — 20.0 20.0 — 20.0 20.0 — 20.0 20.0 — 20.0 20.0 — 20.0 15.0 7.5 22.5 15.0 7.5 22.5 15.0 7.5 22.5 20.0 10.0 30.0 20.0 10.0 30.0 20.0 10.0 30.0 20.0 10.0 30.0 20.0 10.0 30.0 20.0 10.0 30.0 20.0 10.0 30.0 20.0 10.0 30.0 34 TYPICAL PIPING AND WIRING WEATHERPROOF FUSED DISCONNECT* PER NEC OUTDOOR UNIT MOISTURE INDICATOR SIGHT GLASS* FIELDSUPPLIED POWER ELECTRIC HEATER ACCESSORY POWER WIRES LLSV* CONTROL WIRES FILTER LIQUID DRIER* LINE INDOOR UNIT 40RU INSULATED VAPOR LINE CONDENSATE DRAIN POWER WIRES INDOOR THERMOSTAT† FUSED DISCONNECT PER NEC TO OPEN SIGHT DRAIN C09054 LEGEND: NEC --- National Electrical Code TXV --- Thermostatic Expansion Valve * Field --- supplied { Double riser may be required. Consult condensing unit product data catalog for details. NOTES: 1. All piping must follow standard refrigerant piping techniques. Refer to Carrier System Design Manual for details. 2. All wiring must comply with the applicable local and national codes. 3. Wiring and piping shown are general points-of-connection guides only and are not intended for, or to include all details for, a specific installation. 4. Liquid line solenoid valve (solenoid drop control) is recommended to prevent refrigerant migration to the compressor. 5. Internal factory-supplied TXVs not shown. 35 TYPICAL PIPING AND WIRING (cont.) 40RU VERTICAL INSTALLATION - 40RU (TYPICAL) C09055 LEGEND: LLSV --- Liquid Line Solenoid Valve NEC --- National Electrical Code TXV --- Thermostatic Expansion Valve * Field --- supplied { Double riser may be required Consult condensing unit product data catalog ro details. NOTES: 1. All piping must follow standard refrigerant piping techniques. Refer to Carrier System Design Manual for details. 2. All wiring must comply with the applicable local and national codes. 3. Wiring and piping shown are general points-of-connection guides only and are not intended for, or to include all details for, a specific installation. 4. Liquid line solenoid valve (solenoid drop control) is recommended to prevent refrigerant migration to the compressor. 5. Internal factory-supplied TXVs not shown. 36 TYPICAL PIPING AND WIRING (cont.) 40RU WIRE ROUTING, BASE UNIT 40RU C09048 WIRE ROUTING, UNIT WITH ELECTRIC HEAT - 40RU C09049 37 TYPICAL CONTROL WIRING SCHEMATIC HEATER CONTROL BOX TERMINAL BLOCK TB1 FIELD POWER DISCONNECT HC1 L1 L2 HTR1 HC1 SUPPLY L3 3-Ph ONLY EQUIP GND 40RU CIRCUIT BREAKER (5 HP AND LARGER) 40RU CONTROL BOX TERMINAL BLOCK TB1 IFC 11 21 BLK 1 12 22 BLK 2 13 23 BLK 3 IFM UNIT WIRING FIELD POWER WIRING R HEATER CONTROL BOX TERMINAL BLOCK TB2 Y1 Y2 W1 W1 W2 W2 G C WHT C1 IFC C2 C WHT X R Y1 Y2 CONNECT TO 24 VAC AT CONDENSING UNIT W1 W2 G C X THERMOSTAT C09050 38 APPLICATION DATA Operating limits transition is recommended at the fan outlets, but a plenum can be used with slight reduction in external static pressure capability. 40RU07-14 . . . . . . . . . . . . . . . . . . . . . 1200 RPM(20 R/S) General IMPORTANT: underground. Do not bury refrigerant piping Select equipment to match or to be slightly less than peak load. This provides better humidity control, less unit cycling, and less part-load operation. Equipment should be selected to perform at no less than 300 cfm/ton (40 L/s per kW). The air handler fan must always be operating when the condensing unit is operating. For variable air volume (VAV) systems with supply-toreturn air recycling, use the equipment room as a return air plenum. Hot gas bypass Hot gas bypass may be required for low load control in certain applications. Hot gas should only be used during first stage cooling operation and should be applied to all evaporator circuits that are active at that time. To apply hot gas bypass, the 40RU unit will require a field-installed auxiliary side connector(s). See the Auxiliary Side Connector Data table for part numbers. Ductwork should be sized according to unit size, not building load. For larger units with two fans, a split duct AUXILIARY SIDE CONNECTOR DATA UNIT 40RUA 07 08 12 14 16 CARRIER P/N EA19BA705 EA19BA905 EA19BA705 EA19BA705 EA19BA705 INLET/OUTLET DIAMETER — ODF (in.) 11/8 13/8 11/8 11/8 11/8 AUXILIARY (Hot Gas) DIAMETER — ODF (in.) 5/ 8 7/ 8 5/ 8 5/ 8 5/ 8 FACTORY-INSTALLED NOZZLE AND DISTRIBUTOR DATA UNIT COIL TYPE 40RUA07 40RUA08 40RUA12 4 Row 4 Row 4 Row 40RUA14 4 Row TXV Qty...Part No. DISTRIBUTOR Qty...Part No.† 1...BBIZE--- 5--- GA 1...BBIZE--- 6--- GA 2...BBIZE--- 4--- GA 2...BBIZE--- 5--- GA 2...BBIZE--- 5--- GA 1...1135 1...1136 2...1135 2...1135 2...1113 * Feeder tube size is 1/4 in. (6.35 mm) NOTE: Hot gas bypass applications require field-supplied auxiliary side connector. 39 FEEDER TUBES PER DISTRIBUTOR* Qty...Size (in.) 12...1/4 15...1/4 9...1/4 9...1/4 12...3/16 NOZZLE Qty...Part No. 1...G4 1...G5 2...G3 2...G4 2...G3 40RU Maximum fan speed APPLICATION DATA (cont.) FAN MOTOR DATA STANDARD MOTOR — U.S. 40RU UNIT 40RUA 07 40RUA/S 08 208/230-1-60 Speed (rpm) 1725 1725 Hp 1.3 2.4 Frame (NEMA) 56Y 56Y 5/ 5/ Shaft Dia (in.) 8 8 208/230-3-60 and 460-3-60 Speed (rpm) 1725 1725 Hp 2.4 2.4 Frame (NEMA) 56Y 56Y 5/ 5/ Shaft Dia (in.) 8 8 575-3-60 Speed (rpm) 1725 1725 Hp 1.0 2.0 Frame (NEMA) 56 56HZ 5/ 7/ Shaft Dia (in.) 8 8 LEGEND: NEMA — National Electrical Manufacturers Association (U.S.A.) 40RUS 10 40RUA/S 12 40RUA/S 14 40RUA/S 16 1725 2.4 56Y 5/ 8 — — — — — — — — — — — — 1725 2.4 56Y 1725 2.4 56Y 1725 2.4 56Y 1725 3.7 56Y 1725 2.0 56HZ 1725 2.0 56HZ 1725 3.0 56HZ 1725 3.0 56HZ 40RUS 10 40RUA 12 40RUA 14 40RUA 16 1725 2.4 56Y 5/ 8 — — — — — — — — — — — — 1725 2.9 56Y 1725 3.7 Y56Y 1725 3.7 Y56Y 7/ 8 1725 5.0 S184T 11/8 1725 3.0 56HZ 1725 3.0 56HZ 1745 5.0 184T 11/8 1745 5.0 184T 11/8 5/ 8 5/ 8 7/ 8 7/ 8 7/ 8 7/ 8 7/ 8 7/ 8 ALTERNATE MOTOR — U.S. UNIT 40RUA 07 40RUA/S 08 208/230-1-60 Speed (rpm) 1725 1725 Hp 2.4 2.4 Frame (NEMA) 56Y 56Y 5/ 5/ Shaft Dia (in.) 8 8 230-3-60 and 460-3-60 Speed (rpm) 1725 1725 Hp 2.9 2.9 Frame (NEMA) 56Y 56Y 7/ 7/ Shaft Dia (in.) 8 8 575-3-60 Speed (rpm) 1725 1725 Hp 2.0 3.0 Frame (NEMA) 56HZ 56HZ 7/ 7/ Shaft Dia (in.) 8 8 LEGEND: NEMA — National Electrical Manufacturers Association (U.S.A.) 7/ 8 7/ 8 7/ 8 7/ 8 MOTOR EFFICIENCY 40RUA/S MOTOR HP EPACT MINIMUM 1.3* — 2.4 — 2.9 — 3.7 — 5.0 87.5% 7.5 88.5% 10.0 89.5% LEGEND: EPACT --- Energy Policy and Conservation Act of 1992 * Single-phase only. MOTOR EFFICIENCY 70% 82% 82% 84% 87.5% 88.5% 89.5% 40 APPLICATION DATA (cont.) 40RUA 07 UNIT 40RUA/S 08 40RUS 10 40RUA/S 12 40RUA/S 14 40RUA/S 16 28.75 1.79 56Y 15.9 — — — — — — — — — — — — 28.75 1.79 56Y 15.9 28.75 1.79 56Y 15.9 28.75 2.16 56Y 22.2 28.75 2.76 56Y 22.2 28.75 1.49 56HZ 22.2 28.75 1.49 56HZ 22.2 28.75 2.24 56HZ 22.2 28.75 2.24 56HZ 22.2 208/230-1-60 Speed (r/s) 28.75 28.75 Shaft kW 0.97 1.79 Frame (NEMA) 56Y 56Y Shaft Dia (mm) 15.9 15.9 208/230-3-60 and 460-3-60 Speed (r/s) 28.75 28.75 Shaft kW 1.79 1.79 Frame (NEMA) 56Y 56Y Shaft Dia (mm) 15.9 15.9 575-3-60 Speed(r/s) 28.75 28.75 Shaft kW 0.75 1.49 Frame (NEMA) 56 56HZ Shaft Dia (mm) 15.9 22.2 LEGEND: NEMA — National Electrical Manufacturers Association (U.S.A.) ALTERNATE MOTOR — SI 40RUA 07 UNIT 40RUA/S 08 40RUS 10 40RUA/S 12 40RUA/S 14 40RUA/S 16 28.75 1.79 56Y 15.9 — — — — — — — — — — — — 28.75 2.16 56Y 22.2 28.75 2.76 Y56Y 22.2 28.75 2.76 Y56Y 22.2 29.08 3.73 S184T 28.6 28.75 2.24 56HZ 22.2 28.75 2.24 56HZ 22.2 29.08 3.73 184T 28.6 29.08 3.73 184T 28.6 208/230-1-60 Speed (r/s) 28.75 28.75 Shaft kW 1.79 1.79 Frame (NEMA) 56Y 56Y Shaft Dia (mm) 15.9 15.9 208/230-3-60 and 460-3-60 Speed(r/s) 28.75 28.75 Shaft kW 2.16 2.16 Frame (NEMA) 56Y 56Y Shaft Dia (mm) 22.2 22.2 575-3-60 Speed (r/s) 28.75 28.75 Shaft kW 1.50 2.24 Frame (NEMA) 56HZ 56HZ Shaft Dia (mm) 22.2 22.2 LEGEND: NEMA — National Electrical Manufacturers Association (U.S.A.) STANDARD DRIVE DATA, 60 Hz — U.S. UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (in.) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (in.) Pulley Bore (in.) Belt No. — Section Belt Pitch (in.) FAN SPEEDS (rpm) Factory Settings Range Max Allowable Speed (rpm) Change per 1/2 turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (in.) 40RUA 07 40RUA/S 08 40RUS 10 40RUA/S 12 40RUA/S 14 40RUA/S 16 2.4-3.4 2.8-3.8 2.8-3.8 3.4-4.4 2.8-3.8 2.8-3.8 2.5 2.5 2.5 2.5 2.5 2.5 8.8 1 1—A 40.3 8.8 1 1—A 41.3 8.8 1 1—A 41.3 8.8 1 1—A 42.3 9.0 17/16 1—A 42.3 9.0 17/16 1—A 42.3 568 470-666 1200 647 549-745 1200 647 549-745 1200 764 666-863 1200 632 537-728 1200 632 537-728 1200 19.6 19.6 19.6 19.7 19.1 19.1 5 5 5 5 5 5 10.4412.32 10.4412.32 41 10.4412.32 10.4412.32 10.4412.32 10.4412.32 40RU FAN MOTOR DATA (cont) STANDARD MOTOR — SI APPLICATION DATA (cont.) MEDIUM-STATIC DRIVE DATA, 60 Hz — U.S. 40RU UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (in.) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (in.) Pulley Bore (in.) Belt No. — Section Belt Pitch (in.) FAN SPEEDS (rpm) Factory Setting Range Max Allowable Speed (rpm) Change per 1/2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (in.) 40RUA 07 40RUA/S 08 40RUS 10 40RUA/S 12 40RUA/S 14 40RUA/S 16 3.4-4.4 3.4-4.4 3.4-4.4 3.4-4.4 3.4-4.4 3.4-4.7 2.5 2.5 2.5 2.5 2.5 3.0 8.8 1 1—A 42.3 8.0 1 1—A 40.3 8.0 1 1—A 40.3 8.0 1 1—A 40.3 8.2 17/16 1—A 41.3 8.6 17/16 1—B 41.8 764 666-863 1200 841 733-949 1200 841 733-949 1200 841 733-949 1200 820 715-926 1200 842 742--- 943 1200 19.7 21.6 21.6 21.6 21.1 16.7 5 10.4412.32 5 5 10.4412.32 10.4412.32 5 5 6 10.4412.32 10.4412.32 10.4412.32 HIGH-STATIC DRIVE DATA, 60 Hz — U.S. UNIT MOTOR DRIVE Motor Pulley Pitch Diameter (in.) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (in.) Pulley Bore (in.) Belt No. — Section Belt Pitch (in.) FAN SPEEDS (rpm) Factory Setting Range Max Allowable Speed (rpm) Change per 1/2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION 40RUA 07 40RUA/S 08 40RUS 10 40RUA/S 12 40RUA/S 14 40RUA/S 16 3.4-4.4 3.4-4.4 3.4-4.4 3.4-4.4 3.7-4.7 4.3--- 5.3 2.5 2.5 2.5 2.5 3.0 3.0 7.0 1 1—A 41.3 6.0* 1 1—A 37.3 6.0 1 1—A 37.3 6.0 1 1—A 37.3 7.4 17/16 1—B 39.8 7.9 17/16 1—B 39.8 961 8381084 1200 1121 9781200*† 1200 1121 9781200† 1200 1121 9781200† 1200 979 8731096 1200 1060 9501171 1200 24.6 28.7 28.7 28.7 19.4 18.4 5 5 5 5 6 6 10.4410.4410.4410.4410.4412.32 12.32 12.32 12.32 12.32** * Values for 3-phase motor shown. For single-phase motor, pulley pitch diameter is 7 in. and resulting fan speed is 837-1096 rpm. † It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT exceed 1200 rpm. ** 575-v unit has a center distance of 9.16-10.99. SHAFTS CENTER DISTANCE (in.) 42 9.1610.99 APPLICATION DATA (cont.) STANDARD DRIVE DATA, 60 Hz — SI UNIT 40RUA 07 40RUA/S 08 40RUS 10 40RUA/S 12 40RUA/S 14 40RUA/S 16 Motor Pulley Pitch Diameter (mm) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (mm) Pulley Bore (mm) Belt No. — Section Belt Pitch (mm) FAN SPEEDS (r/s) Factory Setting Range Max Allowable Speed (r/s) Change per 1/2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (mm) 61.086.4 71.196.5 71.196.5 86.4111.8 71.196.5 71.196.5 2.5 2.5 2.5 2.5 2.5 2.5 224 25.4 1—A 1024 224 25.4 1—A 1049 224 25.4 1—A 1049 224 25.4 1—A 1074 229 36.5 1—A 1074 229 36.5 1—A 1074 9.5 7.8-11.1 20.0 10.8 9.2-12.4 20.0 10.8 9.2-12.4 20.0 12.7 11.1-14.4 20.0 10.5 9.0-12.1 20.0 10.5 9.0-12.1 20.0 0.327 0.327 0.327 0.328 0.318 0.318 5 5 5 5 5 5 265-313 265-313 265-313 265-313 265-313 265-313 40RUA/S 12 40RUA/S 14 40RUA/S 16 MEDIUM-STATIC DRIVE DATA, 60 Hz — SI UNIT 40RUA 07 40RUA/S 08 40RUS 10 MOTOR DRIVE Motor Pulley Pitch Diameter (mm) Pulley Factory Setting Full Turns Open FAN DRIVE Pulley Pitch Dia (mm) Pulley Bore (mm) Belt No. — Section Belt Pitch (mm) FAN SPEEDS (r/s) Factory Setting Range Max Allowable Speed (r/s) Change per 1/2 Turn of Moveable Motor Pulley Flange MAX FULL TURNS FROM CLOSED POSITION SHAFTS CENTER DISTANCE (mm) 86.4111.8 86.4111.8 86.4111.8 86.4111.8 86.4111.8 94.0119.4 2.5 2.5 2.5 2.5 2.5 3.0 224 25.4 1—A 1074 203 25.4 1—A 1024 203 25.4 1—A 1024 203 25.4 1—A 1024 208 36.5 1—A 1049 218 36.5 1—B 1062 12.7 11.1-14.4 20.0 14.0 12.2-15.8 20.0 14.0 12.2-15.8 20.0 14.0 12.2-15.8 20.0 13.7 11.9-15.4 20.0 14.0 12.4--- 15.7 20.0 0.328 0.360 0.360 0.360 0.352 0.278 5 5 5 5 6 6 265-313 265-313 265-313 265-313 265-313 265-313 43 40RU MOTOR DRIVE APPLICATION DATA (cont.) HIGH-STATIC DRIVE DATA, 60 Hz — SI UNIT 40RUA 07 40RUA/S 08 40RUS 10 40RUA/S 12 40RUA/S 14 40RUA/S 16 86.4111.8 94.0119.4 109.2134.6 MOTOR DRIVE 40RU Motor Pulley Pitch Diameter (mm) 86.4111.8 86.4111.8 86.4111.8 Pulley Factory Setting 2.5 2.5 2.5 2.5 3.0 3.0 Full Turns Open FAN DRIVE Pulley Pitch Dia (mm) 178 152* 152* 152 188 201 Pulley Bore (mm) 25.4 25.4 25.4 25.4 36.5 36.5 Belt No. — Section 1—A 1—A 1—A 1—A 1—B 1—B Belt Pitch (mm) 1049 947 947 947 1011 1011 FAN SPEEDS (r/s) Factory Setting 16.0 18.7 18.7 18.7 16.3 17.7 Range 14.0-18.1 16.3-20.0*† 16.3-20.0*† 16.3-20.0† 14.4-18.3 15.8--- 19.5 Max Allowable Speed (r/s) 20.0 20.0 20.0 20.0 20.0 20.0 Change per 1/2 Turn of Moveable Motor Pulley 0.410 0.478 0.478 0.478 0.323 0.307 Flange MAX FULL TURNS FROM 5 5 5 5 6 6 CLOSED POSITION SHAFTS CENTER DISTANCE (mm) 265-313 265-313 265-313 265-313 265-313** 232--- 279 * Values for 3-phase motor shown. For single-phase motor, pulley pitch diameter is 178 mm and resulting fan speed is 14.0-18.3 r/s. † It is possible to adjust drive so that fan speed exceeds maximum allowable. DO NOT exceed 20 r/s. ** 575-v unit has a center distance of 233-279. 44 GUIDE SPECIFICATIONS Commercial Packaged Air-Handling Unit and condensate drain pans for vertical or horizontal configurations. HVAC Guide Specifications A. Base Unit: Size Range: 2,400 to 6,000 Cfm (1150 to 2830 L/s), Nominal Airflow, 6 to 15 Tons (21 to 52 kW), Nominal Cooling 1. Cabinet shall be constructed of mill-galvanized steel. Part 1 — GENERAL 1.01 SYSTEM DESCRIPTION A. Indoor, packaged air-handling unit for use in commercial split systems. Unit shall have a multi-- position design and shall be capable of horizontal or vertical installation on a floor or in a ceiling, with or without ductwork. (Only vertical units are to be applied without ductwork.) 3. Unit shall contain non-corroding condensate drain pans for both vertical and horizontal applications. Drain pans shall have connections on right and left sides of unit to facilitate field connection. Drain pans shall have the ability to be sloped toward the right or left side of the unit to prevent standing water from accumulating in pans. B. Unit with direct-expansion coil shall be used in a refrigerant circuit with a matching air-cooled condensing unit. Unit with chilled water coil shall be used in a chilled water circuit. 4. Unit shall have factory-supplied 2-in. (51 mm) throwaway-type filters installed upstream from the cooling coil. Filter access shall be from either the right or left side of the unit. 1.02 QUALITY ASSURANCE A. Coils shall be designed and tested in accordance with ASHRAE 15 Safety Code for Mechanical Refrigeration (U.S.A.), latest edition. B. Coils: B. Unit shall be constructed in accordance with ETL (U.S.A.) and ETL, Canada, standards and shall carry the ETL and ETL, Canada, labels. DX coil is 4-- row and consists of copper tubes with sine-wave aluminum fins bonded to the tubes by mechanical expansion. Suction and liquid line connections or supply and discharge connections shall be made on the same side of the coil. C. Unit insulation and adhesive shall comply with NFPA-90A (U.S.A.) requirements for flame spread and smoke generation. Insulation shall contain an EPA-registered immobilized antimicrobial agent to effectively resist the growth of bacteria and fungi as proven by tests in accordance with ASTM standards G21 and 22 (U.S.A.). 1. Direct-expansion coils shall feature factory installed thermostatic expansion valves (TXVs) for refrigerant control. The TXVs shall be Puronr R-- 410A compatible and capable of external adjustment. Direct-expansion heat pump coils shall have a factory-installed bypass line and check valve assembly around the TXVs to allow liquid flow from the coil to the outdoor unit during the heating mode. Coil tubing shall be internally rifled to maximize heat transfer. D. Unit shall be manufactured in a facility registered to the ISO 9001:2000 manufacturing quality standard. E. Direct-expansion and chilled water coils shall be burst and leak tested at 435 psi (2999 kPa). 2. Chilled water coils shall be rated for an operating pressure of not less than 300 psig (2069 kPag). 1.03 DELIVERY AND STORAGE Units shall be stored and manufacturer’s recommendations. handled per C. Operating Characteristics: Part 2 — PRODUCTS Unit shall be capable of providing airflow at an external static pressure of (kPag). 2.01 EQUIPMENT Indoor mounted, draw-thru, packaged air-handling unit that can be used in a suspended horizontal configuration or a vertical configuration. Unit shall consist of forward-curved belt-driven centrifugal fan(s), motor and drive assembly, pre-- wired fan motor contactor, factory-installed refrigerant metering devices (direct-expansion coil units), cooling coil, 2-in. (51-mm) disposable air filters, cfm (L/s) in. wg D. Motor: 1. Fan motor of the size and electrical characteristics specified on the equipment schedule shall be factory supplied and installed. 45 40RU 2. Cabinet panels shall be fully insulated with 1/ -in. (12.7-mm) fire-retardant material. 2 Insulation shall contain an EPA-registered immobilized antimicrobial agent to effectively resist the growth of bacteria and fungi as proven by tests in accordance with ASTM standards G21 and 22 (U.S.A.). Carrier Model Numbers: 40RUA (Direct-Expansion Coil) 40RUS (Chilled Water Coil) GUIDE SPECIFICATIONS (cont.) 40RU 2. Motors rated at 1.3 through 3.7 hp (0.97 through 2.76 kW) shall have internal thermal overload protection. Motors rated at 5 hp (3.73 kW) shall be protected by a circuit breaker. 5. Electric Heaters: Heaters for nominal 240, 480, or 575-volt, 3-phase, 60 Hz shall be factory-supplied for field installation as shown on the equipment drawings. Electric heat assembly shall be ETL (U.S.A.) and ETL, Canada, agency approved, and shall have single-point power wiring. Heater assembly shall include contactors with 24-v coils, power wiring, 24-v control wiring terminal blocks, and a hinged access panel. Electric heaters shall not be used with air discharge plenum. 3. Evaporator-fan motor shall have permanently lubricated, sealed bearings and inherent automatic-reset thermal overload protection or manual reset calibrated circuit breakers. Evaporator motors are designed specifically for Carrier and do not have conventional horsepower (hp) ratings listed on the motor nameplate. Motors are designed and qualified in the “air-over” location downstream of the cooling coil and carry a maximum continuous bhp rating that is the maximum application bhp rating for the motor; no “safety factors” above that rating may be applied. 6. Air Discharge Plenum: Plenum shall be factory-supplied to provide free-blow air distribution for vertical floor-mounted units. A grille with moveable vanes for horizontal or vertical airflow adjustment shall be included. Plenum shall be field-assembled and field-installed on the unit’s fan deck for blow-thru air distribution. Plenum shall not be used with electric heaters. 4. All evaporator-fan motors 5 hp and larger shall meet the minimum efficiency requirements as established by the Energy Policy Act of 1992 (EPACT), effective October 24, 1997. E. Special Features: 7. Return-Air Grille: 1. Alternate Motor and Drive: Grille shall be factory-supplied for field installation on the unit’s return air opening. An alternate motor and/or medium-static or high-static drive shall be available to meet the airflow and external static pressure requirements specified on the equipment schedule. 8. Unit Subbase: Subbase assembly shall be factory-supplied for field installation. Subbase shall elevate floor-mounted vertical units to provide access for correct condensate drain connection. 2. External Paint: Where conditions require, units shall be painted with an American Sterling Gray finish. 9. Economizer: 3. Hot Water Coil: Economizer for ventilation or “free” cooling shall be factory provided for field installation on either return air opening of air handler. For free cooling applications, economizer shall be compatible with separate thermostat; economizer dampers shall open when outdoor air enthalpy is suitable for free cooling. Economizer shall be compatible with separate CO2 sensor accessory; economizer dampers shall open when indoor CO2 level rises above predetermined set point. Economizer shall include enthalpy control and damper actuator. Coil shall be 2-row, U-bend coil with copper tubes and aluminum plate fins bonded to the tubes by mechanical expansion. Coil shall be mounted in a galvanized steel housing that shall be fastened to the unit’s fan deck for blow-thru heating operation. Coil shall have maximum working pressure of 150 psig (1034 kPag). 4. Steam Distributing Coil: Coil shall consist of one row of copper tubes with aluminum plate fins, and shall have inner steam distributing tubes. Coil shall be mounted in a galvanized steel housing and shall be fastened to the unit’s fan deck for blow-thru heating operation. Coil shall have maximum working pressure of 20 psig at 260_F (138 kPag at 126_C). 46 GUIDE SPECIFICATIONS (cont.) 10. Thermostat Controls: 14. UV-C Germicidal Lamps: b. Commercial Electronic Thermostat with 7-day time clock, auto-changeover, multi-stage capability, and large LCD temperature display. b. UV-C power supplies shall be high efficiency, electric type which are matched to the emitters and are capable of producing the specified output intensity with an input power no more than 80 watts. 11. Overhead Suspension Package: Package shall include necessary brackets to support units in a horizontal ceiling installation. c. Emitters and fixtures shall be installed in sufficient quantity and arranged so as to provide an equal distribution of UV-C energy on the coil and drain pan. 12. CO2 Sensor: Sensor shall provide the ability to signal the economizer to open when the space CO2 level exceeds the predetermined setpoint. Sensor shall have the capability of being connected to Comfort System relay pack or to economizer using field-supplied and field-installed Honeywell dc adapter no. Q769C1004. d. The minimum UV-C energy striking the leading edge of the coil fins shall be not less than 820 μW/cm2 at the closest point and through placement, not less than 60% of that value at the farthest point. Equal amounts are to strike the drain pan, either directly or indirectly through reflection. 13. Condensate Drain Trap: Trap shall have transparent, serviceable design for easy cleaning. Kit shall include overflow shutoff switch and wiring harness for connection to an alarm if desired. 47 40RU a. UV-C emitters and fixtures shall be specifically designed for use inside an HVAC system. An ASME nozzled test apparatus using a 45_F (7.2 C) airstream moving at not less than 400 fpm (189 liters/sec.) shall measure individual lamp output. Lamp output at 253.7 nm shall not be less than 10μW/cm2 per inch of arc length measured at a distance of one meter. a. TEMP System programmable communicating multi-stage thermostat with fan switch, time clock, LCD display, _F/_C capability, and CCN (Carrier Comfort Network®) compatibility. 40RU Edition Date: 04/09 Catalog No: 40RU ---01PD Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: NEW Copyright 2009 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. 48
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2009:09:25 13:49:54-04:00 Create Date : 2009:04:30 13:53:57-04:00 Metadata Date : 2009:09:25 13:49:54-04:00 Format : application/pdf Title : 40ru-01pd Creator : bact625 Producer : Acrobat Distiller 8.1.0 (Windows) Document ID : uuid:5d43e58d-a84b-4b2c-9a24-930f9b55b5a6 Instance ID : uuid:f4f20f74-090f-4ebc-bdbe-0aaa5c968582 Page Count : 48 Author : bact625EXIF Metadata provided by EXIF.tools