L_4208SND_D 4208SN Data Sheet
User Manual: 4208SN Data Sheet 4208SN - Honeywell Ademco
Open the PDF directly: View PDF .
Page Count: 1
Download | ![]() |
Open PDF In Browser | View PDF |
4208SN V-PLEX® SERIALIZED EIGHT ZONE REMOTE POINT MODULE The 4208SN Remote Point Module (RPM) is an eight-zone expander that allows the use of available expansion zones on Honeywell VISTA controls that support V-Plex polling loop devices. FEATURES • Can be used on controls that support up to 250 zones • Uniquely identified eight EOLR supervised zones (all zones use 10K • Can be optionally powered from an external DC power supply to reduce resistors, supplied) • Detects faults on all zones within 400ms of occurence • Loops A & B can be programmed for • Each zone is identified by a unique the amount of current draw from the serial number, which is assigned via polling loop on-board DIP switches fast (10ms) response • Provides cover tamper protection, which may be enabled or disabled via on board DIP switches SPECIFICATIONS Physical Expander Sensor Loop Response Agency Listings • 6-7/16" W x 4-1/4" H x 1-1/4" D (163mm x 108mm x 32mm) • Slow: 400msec (all loops) • UL985 Household Fire • Fast: 10msec (option for loops A and B) • UL1023 Household Bulgary Electrical Polling Loop Voltage Expander Sensor Loop Current • UL864 Commercial Fire • 11V nominal; 8.7 - 14VDC range • 0.52mA (normal) • CSFM • 1.3mA (shorted) • FM (Pending) • 33.6mA when polling loop provides power to module, 0.6mA when 12VDC input provides power to module. See chart below. NOTE: These currents apply wneh polling loop input = 11VDC and 10VDC input is not connected to external supply • CUL 12VDC Input Voltage Sensor Loop Max. Resistance • 12V nominal; 9.4 - 14VDC range • Up to 300 ohms of wire resistence + 10K EOLR Current Current Draw (all zones shorted) Power Input Source From Polling Loop From External Power Polling Loop Only 33.6m AN/A Polling Loop and External Power Input 0.6mA 33mA ORDERING 4208SN Eight Zone Expander For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 www.honeywell.com L/4208SND/D May 2009 © 2009 Honeywell International Inc. • UL609 Commercial Burglary • CE (requires #N6361) For UL Listed Commercial Fire Usage: Use N.O. contacts. Style B supervise these loops using Model #EOL 100 fire listed 10K EOLRs (purchased separately). For UL Listed Commercial Burglary Usage: Use N.O. or N.C. contacts. Supervise using EOLRs supplied.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2009:06:24 15:47+05:30 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2009:06:30 15:49:07-04:00 Metadata Date : 2009:06:30 15:49:07-04:00 Format : application/pdf Creator : Title : L_4208SND_D:L_4208SND_D.qxd Subject : 4208SN, V-PLEX® SERIALIZED EIGHT ZONE REMOTE POINT MODULE Document ID : uuid:b8c63f40-f0ba-40a6-9ac3-4b4d819efd8b Instance ID : uuid:40ab1d17-67df-49c0-915f-37391c62ade9 Page Count : 1 Page Layout : SinglePage Keywords : 4208SN, V-PLEX®, SERIALIZED, EIGHT, ZONE, REMOTE, POINT, MODULEEXIF Metadata provided by EXIF.tools