PerkinElmer Series 200 HPLC Brochure 44 74465BRO Series200HPLCSystems

User Manual: Series 200

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadPerkinElmer Series 200 HPLC - Brochure 44-74465BRO Series200HPLCSystems
Open PDF In BrowserView PDF
PerkinElmer Series 200
HPLC Systems

designed to

never let you down

an inside look at the

Series 200 HPLC systems
PerkinElmer knows you need to rely on your high
performance liquid chromatography (HPLC) system
to get the job done day-in and day-out. That’s why
we designed and built the Series 200 family of HPLC
instruments.
We’re confident the Series 200 HPLC family will meet
and exceed the liquid chromatography demands of your
lab, because each component – from pump to data handling – has proven track records behind them. Best of all,
all of our systems are backed by our renowned global
service and support organization, so you know you can
depend on them today, tomorrow and for years to come.

The brains behind the brawn –
TotalChrom CDS
Acquiring, processing, reporting, reviewing and
approving data is a streamlined series of operations
in PerkinElmer®’s TotalChrom® Chromatography Data
System (CDS) software, designed to fit your laboratory
workflow and maximize productivity. With its scalable
architecture, 21 CFR Part 11 compliance features and
proven algorithms, TotalChrom offers a computing
strategy to manage your chromatography data quickly
and securely in both regulated and non-regulated
environments. TotalChrom data systems can be
deployed in standalone, thin client, or enterprise
client/server computing environments.

SoftLINK™: entry-level solution for
instrument connectivity
Designed for one instrument, workstation
environments, SoftLINK provides instrument
connectivity at a glance.
dotLINK™: interfacing with ease
dotLINK is a Windows CE-based interface
that allows you to connect your Series 200
directly to the network. Designed to face
today’s workload challenges and provide
Ethernet connectivity, dotLINK allows external
buffering with a minimal need for validation.

2

rugged and reliable – the

Series 200 Analytical Pump
Designed to work in applications where minimal
downtime and low maintenance are a must, the
proven, rugged design of the Series 200 Analytical
Pump offers low piston wear for less downtime and
lower cost of ownership.
Precise blending through advanced engineering is
obtained by the Series 200 using a design that allows
automatic compensation of solvent compressibility
during each pump stroke. This feature plus two-point
flow calibration ensure greater accuracy, highly-precise
flow rates, and high-performance gradient capability.
True mixing volume correction using the chemist’s
approach is obtained precisely and reliably, run after run.
That is why thousands of laboratories worldwide
have chosen to rely on PerkinElmer’s unique pumping technology.

Low, precise microflows –
the Series 200 Micro Pump
The Series 200 Micro Pump, with its ultra-low delay
volume, is ideal for narrowbore chromatography –
or as a front-end to your LC/MS. The Series 200 Micro
Pump offers superior flow rate precision, compositional
accuracy, and retention-time precision for either isocratic
or gradient separations. The Series 200 Micro Pump is
available in isocratic or binary high pressure blending
with user customizable mixing. Whenever “no delay
volume” and “ultra-fast gradient” are required, the Series
200 Micro Pump is the solution for your applications.
Growing platform to match your needs
Pumps can be upgraded to additional solvent
capabilities right in your lab. Start with a simple
isocratic and expand to binary or quaternary
to match your needs.

w w w. p e r k i n e l m e r. c o m

3

fast, accurate and flexible –
the

Series 200 Autosampler

Need speed? Reliability? Flexible
sampling? The Series 200 Autosampler
does it all!
The Series 200 Autosampler rapidly brings the needle
to the sample, eliminating the time, complexity and
unreliability of moving sample vials, while providing
support for numerous sample container formats. Select
your injection volume, needle height and flush cycles
to be able to analyze every sample in the most suitable
analytical conditions.
The fast, flexible and ultra-reliable sampling – up to
three injections per minute – is due to the unique, all
gear-driven drive mechanism.

Key features
• Advanced design for injection valve flushing and
external needle wash reduces carryover – offers
a 0.005% carryover specification.
• Impressive injection linearity for uncompromised
quantitative analysis and method development.
• Boasts the industry’s best on-board automated
derivatization/dilution performance of any
analytical autosampler. It is now easy and takes
little time to prepare solutions for calibration
curves and internal standard (ISTD) addition.
• Easily interchangeable, cost-effective sample
trays. Choose from over 13 different tray/
sampling formats. High-capacity sample trays
can accommodate up to 225 vials or two 96- or
two 384-well plates with full control of needle
level within sample vials/trays and on-board
temperature control.

precise for increased repeatability –
Column Oven
the

Series 200

The PerkinElmer Series 200 Column Oven controls the
mobile phase and sample temperature before entering
the column via a low dispersion built-in pre-heater.
This eliminates thermal gradients across the column,
resulting in better column performance and precise
retention times. All heating and cooling is performed
electronically, permitting sub-ambient temperatures
without coolant or refrigerants.

solubility, resulting in better resolution and/or increased speed of analysis. Sub-ambient temperature
capabilities are helpful in many biomolecular analyses
and in the analysis of some chiral compounds.

By maintaining the column temperature at a stable
set point, more standardized results
can be obtained, permitting better
day-to-day and lab-to-lab comparison of results. In addition, elevated temperatures can be used
in many applications to decrease
mobile phase viscosity while increasing mass transfer and sample

w w w. p e r k i n e l m e r. c o m

5

Series 200
Getting answers not just data –
the Series 200 PDA

Stable and ready for any challenge –
the Series 200 UV/Vis Detector

The Series 200 Photo Diode Array (PDA) Detector,
provides true UV/Vis detection and high resolution
spectral data. The Series 200 PDA is fully networkcompatible, providing fast and secure transmission
of chromatographic and spectral data.

The Series 200 UV/Vis Detector is a solid foundation
for your total HPLC system, offering the highest sensitivity and outstanding linearity performance – even
at extremely high or low concentrations – 24 hours-a-day,
seven days-a-week.

The excellent signal-to-noise characteristics of the
Series 200 Diode Array make it ideally suited for
low volume or low concentration samples. In addition,
the spectral data generated by the Series 200 is quickly
and easily processed by our powerful IRIS™ Spectral
Processing Software developed by PerkinElmer. It offers
a full suite of functionality and an intuitive user interface, all protected under a fully 21 CFR Part 11 compliant architecture.

Key features
• The Series 200 UV/Vis supports the full UV/Vis
range from 190 to 700 nm
• Several flow cell formats to choose from to
meet your specific application requirements in
analytical, semi-prep or micro-bore environments.

6

family of detectors

Rugged and easy-to-use –
the Series 200 Refractive Index

Combining sensitivity and specificity –
the Series 200 Fluorimeter

The Series 200 Refractive Index (RI), with its deflectiontype design, allows sensitive detection of these compounds with low noise and drift characteristics. This
advanced detector features internal temperature control
of the flow cell, offset adjustment, autozero, and autopurge of the reference cell – all with easy keypad entry.
An intuitive, built-in Graphical User Interface allows
auto calibration and extended diagnostic plus visualization of the real time signal during and between runs.
The Series 200 RI Detector is a highly stable and sensitive LC and GPC detector for use with compounds
that do not have high absorption in the UV range, such
as polymers, sugars, organic acids and triglycerides.

The Series 200 Fluorescence Detector delivers the
outstanding performance and reliability you’ve come
to expect from PerkinElmer. Although retention time
is the main tool for identification of analytes, the
complexity of real world samples requires the confirmation of peak identity through additional qualitative
information. The major benefit afforded by fluorescence detection is the inherent high sensitivity of the
technique coupled with outstanding specificity – given
that relatively few molecules natively fluoresce. Therefore, the specific excitation and emission wavelength
profile aids in the characterization of individual
components. The Series 200 Fluorimeter far exceeds
common standards of sensitivity. It is a necessary
tool for the most demanding environmental, life
science and food safety applications.

w w w. p e r k i n e l m e r. c o m

7

PerkinElmer, Inc.
There for the installation – and beyond.
The Series 200 HPLC modules and TotalChrom provide
an integrated solution to your most demanding applica-

Expand your field of applications: discover the
PerkinElmer’s Radio-Flow detection technology:
Radiomatic 150TR

tion requirements. From getting a new product to market

The Radiomatic 150TR is a complete flow scintillation

to performing routine QA/QC analysis, the Series 200

analyzer that is optimized for monitoring single- or dual-

HPLC systems powered by TotalChrom will help you

labeled radioisotopic samples separated by liquid

to streamline your laboratory workflow. Best of all,

chromatography. The Radiomatic 150TR detector

PerkinElmer also has the know-how and resources

platform uses state-of-the-art scintillation counting

to deliver best-in-class service from initial setup

technology and can be used as a stand-alone detector

and installation to preventive maintenance.

with on-board chromatography data reduction or
integrated into the Series 200 system.

Discover PerkinElmer’s high-throughput instrumentation offerings: JANUS Automated Workstation
The JANUS™ Automated Workstation provides enhanced
productivity and adaptability opportunities to meet the
demanding needs of pharmaceutical, biotech and research customers. A scalable automated workstation,
JANUS employs a modular design enabling the addition
and replacement of liquid handling and labware movement
technologies as application and throughput demands evolve.
JANUS is available in three platforms – Standard,
Expanded and Integrator models. Each platform can be
configured with a choice of pipetting modules to address
throughput requirements and labware movement arms for
walk-away capability. As application demands change,

JANUS Automated Workstation

JANUS’ modularity allows system upgrades accordingly.
WinPREP® for JANUS application software provides the
flexibility required for various laboratory applications
without adding time-intensive programming complexity.

PerkinElmer Life and
Analytical Sciences
710 Bridgeport Avenue
Shelton, CT 06484-4794 USA
Phone: (800) 762-4000 or
(+1) 203-925-4602
www.perkinelmer.com
For a complete listing of our global offices, visit www.perkinelmer.com/lasoffices
©2005 PerkinElmer, Inc. All rights reserved. The PerkinElmer logo and design are registered trademarks of PerkinElmer, Inc. dotLINK, IRIS, Janus and SoftLINK are trademarks
and PerkinElmer, TotalChrom and WinPrep are registered trademarks of PerkinElmer, Inc. or its subsidiaries, in the United States and other countries. All other trademarks not
owned by PerkinElmer, Inc. or its subsidiaries that are depicted herein are the property of their respective owners. PerkinElmer reserves the right to change this document at any
time without notice and disclaims liability for editorial, pictorial or typographical errors.
007370_01

Printed in USA



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 8
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 5.0.5 for Macintosh
Create Date                     : 2005:10:31 20:08:29Z
Modify Date                     : 2008:05:22 13:06:29-04:00
Metadata Date                   : 2008:05:22 13:06:29-04:00
Creator Tool                    : QuarkXPress.: LaserWriter 8 8.7.1
Document ID                     : uuid:f81932d0-0a4a-4edb-b79a-622d9fc8598e
Instance ID                     : uuid:bb6fbbc4-ab59-450c-bb95-dda0a4ec13d4
Format                          : application/pdf
Creator                         : PerkinElmer
Title                           : PerkinElmer Series 200 HPLC - Brochure
Lit Num                         : 007370_01
Pub Date                        : 05222008
Author                          : PerkinElmer
EXIF Metadata provided by EXIF.tools

Navigation menu