Manual For The 63061 3/8 In. Composite Air Impact Wrench
User Manual: Manual for the 63061 3/8 in. Composite Air Impact Wrench 3/8 in. Composite Air Impact Wrench
Open the PDF directly: View PDF .
Page Count: 16
Download | ![]() |
Open PDF In Browser | View PDF |
Owner’s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and the receipt in a safe and dry place for future reference. REV 17c Visit our website at: http://www.harborfreight.com Email our technical support at: productsupport@harborfreight.com When unpacking, make sure that the product is intact and undamaged. If any parts are missing or broken, please call 1-888-866-5797 as soon as possible. Copyright© 2015 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein. Tools required for assembly and service may not be included. Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL. Table of contents Safety ......................................................... 2 Maintenance .............................................. 12 Specifications ............................................. 6 Parts List and Diagram .............................. 14 Setup .......................................................... 7 Warranty .................................................... 16 SAFETy Operation ................................................... 10 WARNING SyMBOLS AND DEFINITIONS This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. SETUp Indicates a hazardous situation which, if not avoided, will result in death or serious injury. Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Addresses practices not related to personal injury. OpERATION IMpORTANT SAFETy INSTRUcTIONS INSTRUcTIONS pERTAINING TO A RISK OF FIRE, ELEcTRIc SHOcK, OR INJURy TO pERSONS WARNING – When using tools, basic precautions should always be followed, including the following: General To reduce the risks of electric shock, fire, and injury to persons, read all the instructions before using the tool. MAINTENANcE Work Area 1. Keep the work area clean and well lighted. Cluttered benches and dark areas increase the risks of electric shock, fire, and injury to persons. 3. Keep bystanders, children, and visitors away while operating the tool. Distractions are able to result in the loss of control of the tool. 2. Do not operate the tool in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. The tool is able to create sparks resulting in the ignition of the dust or fumes. Page 2 For technical questions, please call 1-888-866-5797. Item 63061 62835 2. Dress properly. Do not wear loose clothing or jewelry. contain long hair. Keep hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair increases the risk of injury to persons as a result of being caught in moving parts. 3. Avoid unintentional starting. Be sure the switch is off before connecting to the air supply. Do not carry the tool with your finger on the switch or connect the tool to the air supply with the switch on. 5. Do not overreach. Keep proper footing and balance at all times. Proper footing and balance enables better control of the tool in unexpected situations. 6. Use safety equipment. A dust mask, non-skid safety shoes and a hard hat must be used for the applicable conditions. 7. Always wear eye protection. Wear ANSI-approved safety goggles. 8. Always wear hearing protection when using the tool. Prolonged exposure to high intensity noise is able to cause hearing loss. 4. Remove adjusting keys and wrenches before turning the tool on. A wrench or a key that is left attached to a rotating part of the tool increases the risk of personal injury. SETUp 1. Stay alert. Watch what you are doing and use common sense when operating the tool. Do not use the tool while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating the tool increases the risk of injury to persons. SAFETy personal Safety Tool Use and care 3. Do not use the tool if the switch does not turn the tool on or off. Any tool that cannot be controlled with the switch is dangerous and must be repaired. 4. Disconnect the tool from the air source before making any adjustments, changing accessories, or storing the tool. Such preventive safety measures reduce the risk of starting the tool unintentionally. Turn off and detach the air supply, safely discharge any residual air pressure, and release the throttle and/or turn the switch to its off position before leaving the work area. 6. Maintain the tool with care. Keep a cutting tool sharp and clean. A properly maintained tool, with sharp cutting edges reduces the risk of binding and is easier to control. 7. check for misalignment or binding of moving parts, breakage of parts, and any other condition that affects the tool's operation. If damaged, have the tool serviced before using. Many accidents are caused by poorly maintained tools. There is a risk of bursting if the tool is damaged. 8. Use only accessories that are identified by the manufacturer for the specific tool model. Use of an accessory not intended for use with the specific tool model, increases the risk of injury to persons. Service 1. Tool service must be performed only by qualified repair personnel. 3. Use only the lubricants supplied with the tool or specified by the manufacturer. 2. When servicing a tool, use only identical replacement parts. Use only authorized parts. Item 63061 62835 For technical questions, please call 1-888-866-5797. Page 3 OpERATION 2. Do not force the tool. Use the correct tool for the application. The correct tool will do the job better and safer at the rate for which the tool is designed. 5. Store the tool when it is idle out of reach of children and other untrained persons. A tool is dangerous in the hands of untrained users. MAINTENANcE 1. Use clamps or another practical way to secure and support the workpiece to a stable platform. Holding the work by hand or against the body is unstable and is able to lead to loss of control. Air Source 1. SAFETy Never connect to an air source that is capable of exceeding 200 psi. Over pressurizing the tool may cause bursting, abnormal operation, breakage of the tool or serious injury to persons. Use only clean, dry, regulated compressed air at the rated pressure or within the rated pressure range as marked on the tool. Always verify prior to using the tool that the air source has been adjusted to the rated air pressure or within the rated air-pressure range. 2. Never use oxygen, carbon dioxide, combustible gases or any bottled gas as an air source for the tool. Such gases are capable of explosion and serious injury to persons. SAVE THESE INSTRUcTIONS. SETUp Symbols and Specific Safety Instructions Symbol Definitions Symbol no .../min property or statement Symbol property or statement No-load speed NpT National pipe thread, tapered Revolutions or reciprocation per minute NpS National pipe thread, straight OpERATION pSI Pounds per square inch of pressure ft-lb Foot-pounds of torque BpM Blows per minute cFM Cubic Feet per Minute flow ScFM Cubic Feet per Minute flow at standard conditions WARNING marking concerning Risk of Eye Injury. Wear ANSI-approved eye protection. WARNING marking concerning Risk of Hearing Loss. Wear hearing protection. WARNING marking concerning Risk of Respiratory Injury. Wear NIOSH-approved dust mask/respirator. WARNING marking concerning Risk of Explosion. MAINTENANcE Page 4 For technical questions, please call 1-888-866-5797. Item 63061 62835 1. The amount of actual torque may vary depending on the cleanness and condition of the threads and other factors. If tightening critical components, check the actual torque applied to the fastener with a mechanical torque wrench (not supplied). 4. WARNING: The brass components of this product contain lead, a chemical known to the State of California to cause cancer and birth defects or other reproductive harm. (California Health & Safety Code § 25249.5, et seq.) 2. The warnings and precautions discussed in this manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator. 5. Only use with accessories rated to handle the forces exerted by this tool during operation. Other accessories not designed for the forces generated may break and forcefully launch pieces. 6. Attach all accessories properly to the tool before connecting the air supply. A loose accessory may detach or break during operation. 8. Install an in-line shutoff valve to allow immediate control over the air supply in an emergency, even if a hose is ruptured. 9. Use this tool with both hands only. Using tools with only one hand can result in loss of control. OpERATION 10. Do not lay the tool down until it has come to a complete stop. Moving parts can grab the surface and pull the tool out of your control. Vibration precautions This tool vibrates during use. Repeated or long-term exposure to vibration may cause temporary or permanent physical injury, particularly to the hands, arms and shoulders. To reduce the risk of vibration-related injury: 1. Anyone using vibrating tools regularly or for an extended period should first be examined by a doctor and then have regular medical check-ups to ensure medical problems are not being caused or worsened from use. Pregnant women or people who have impaired blood circulation to the hand, past hand injuries, nervous system disorders, diabetes, or Raynaud's Disease should not use this tool. If you feel any symptoms related to vibration (such as tingling, numbness, and white or blue fingers), seek medical advice as soon as possible. 2. Do not smoke during use. Nicotine reduces the blood supply to the hands and fingers, increasing the risk of vibration-related injury. 3. Wear suitable gloves to reduce the vibration effects on the user. 4. Use tools with the lowest vibration when there is a choice. 5. Include vibration-free periods each day of work. 6. Grip tool as lightly as possible (while still keeping safe control of it). Let the tool do the work. 7. To reduce vibration, maintain tool as explained in this manual. If abnormal vibration occurs, stop immediately. SAVE THESE INSTRUcTIONS. Item 63061 62835 SETUp 7. Obey the manual for the air compressor used to power this tool. For technical questions, please call 1-888-866-5797. Page 5 MAINTENANcE 3. WARNING: Some dust created by power sanding, sawing, grinding, drilling, and other construction activities, contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Some examples of these chemicals are: • Lead from lead-based paints • Crystalline silica from bricks and cement or other masonry products • Arsenic and chromium from chemically treated lumber Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to filter out microscopic particles. (California Health & Safety Code § 25249.5, et seq.) SAFETy Specific Safety Instructions Functional Description Specifications SAFETy Maximum Air Pressure 90 PSI Air Inlet Average Air Consumption 6 CFM @ 90 PSI Drive Size (62835) Drive Size (63061) components and controls SETUp Anvil Trigger OpERATION Regulator Knob Air Inlet MAINTENANcE Page 6 For technical questions, please call 1-888-866-5797. Item 63061 62835 Initial Tool Set Up/Assembly Note: For additional information regarding the parts listed in the following pages, refer to the Assembly Diagram near the end of this manual. Note: This air tool may be shipped with a protective plug covering the air inlet. Remove this plug before set up. SAFETy Read the ENTIRE IMpORTANT SAFETy INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. Air Supply 2. Attach an air hose to the compressor's air outlet. Connect the air hose to the air inlet of the tool. Other components, such as a coupler plug and quick coupler, will make operation more efficient, but are not required. WARNING! TO pREVENT SERIOUS INJURy FROM AccIDENTAL OpERATION: Do not install a female quick coupler on the tool. Such a coupler contains an air valve that will allow the air tool to retain pressure and operate accidentally after the air supply is disconnected. Note: Air flow, and therefore tool performance, can be hindered by undersized air supply components. The air hose must be long enough to reach the work area with enough extra length to allow free movement while working. Item 63061 62835 4. Close the in-line shutoff valve between the compressor and the tool. 5. Turn on the air compressor according to the manufacturer's directions and allow it to build up pressure until it cycles off. 6. Adjust the air compressor's output regulator so that the air output is enough to properly power the tool, but the output will not exceed the tool's maximum air pressure at any time. Adjust the pressure gradually, while checking the air output gauge to set the right pressure range. 7. Inspect the air connections for leaks. Repair any leaks found. 8. If the tool will not be used at this time, turn off and detach the air supply, safely discharge any residual air pressure, and release the throttle and/or turn the switch to its off position to prevent accidental operation. 9. Residual air pressure should not be present after the tool is disconnected from the air supply. However, it is a good safety measure to attempt to discharge the tool in a safe fashion after disconnecting to ensure that the tool is disconnected and not powered. For technical questions, please call 1-888-866-5797. Page 7 OpERATION Note: If an automatic oiler system is not used, add a few drops of Pneumatic Tool Oil to the airline connection before operation. Add a few more drops after each hour of continual use. 3. Turn the tool's switch to the off position; refer to Operation section for description of controls. MAINTENANcE 1. Incorporate a filter, regulator with pressure gauge, oiler, in-line shutoff valve, and quick coupler for best service, as shown on Figure A on page 8 and Figure B on page 9. An in-line shutoff ball valve is an important safety device because it controls the air supply even if the air hose is ruptured. The shutoff valve should be a ball valve because it can be closed quickly. SETUp TO pREVENT SERIOUS INJURy FROM EXpLOSION: Use only clean, dry, regulated, compressed air to power this tool. Do not use oxygen, carbon dioxide, combustible gases, or any other bottled gas as a power source for this tool. For technical questions, please call 1-888-866-5797. Description Non-lubricated Tools A Air Hose Filter Regulator Lubricator (optional) Coupler and Plug Leader Hose (optional) Air Cleaner / Dryer (optional) Air Adjusting Valve (optional) MAINTENANcE A B C D E F G H OpERATION Lubricated Tools B B c c A A E E F H Connects air to tool Prevents dirt and condensation from damaging tool or workpiece Adjusts air pressure to tool For air tool lubrication Provides quick connection and release Increases coupler life Prevents water vapor from damaging workpiece For fine tuning airflow at tool G D Function SETUp Figure A: portable Air Supply Setup SAFETy Page 8 Item 63061 62835 Item 63061 62835 For technical questions, please call 1-888-866-5797. Page 9 A B C D E F G H I J K L M N O F Description F E I I J K N J H Function H L L M O SETUp SAFETy For noise and vibration reduction Secures air compressor in place Isolates sections of system for maintenance For vibration reduction Distributes air to branch lines To drain moisture from system Brings air to point of use Connects air to tool Prevents dirt and condensation from damaging tool or workpiece Adjusts air pressure to tool For air tool lubrication Provides quick connection and release Increases coupler life Prevents water vapor from damaging workpiece For fine tuning airflow at tool Non-lubricated Tools c c Lubricated Tools OpERATION Air Hose Filter Regulator Lubricator (optional) Coupler and Plug Leader Hose (optional) Air Cleaner / Dryer (optional) Air Adjusting Valve (optional) Ball Valve Vibration Pads Anchor Bolts Ball Valve Isolation Hose B A MAINTENANcE B A c D G Slope Figure B: Stationary Air Supply Setup F Operating Instructions Read the ENTIRE IMpORTANT SAFETy INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. SAFETy Inspect tool before use, looking for damaged, loose, and missing parts. If any problems are found, do not use tool until repaired. Tool Set Up TO pREVENT SERIOUS INJURy FROM AccIDENTAL OpERATION: Turn off the tool, detach the air supply, safely discharge any residual air pressure in the tool, and release the throttle and/or turn the switch to its off position before performing any inspection, maintenance, or cleaning procedures. SETUp TO pREVENT SERIOUS INJURy: Do not adjust or tamper with any control or component in a way not specifically explained within this manual. Improper adjustment can result in tool failure or other serious hazards. Connect an appropriate, impact rated square drive socket onto the anvil. cAUTION! Only use impact rated accessories with this tool. Other accessories may shatter, chip, or crack during operation. Workpiece and Work Area Set Up 1. Designate a work area that is clean and well-lit. The work area must not allow access by children or pets to prevent distraction and injury. OpERATION 2. Route the air hose along a safe route to reach the work area without creating a tripping hazard or exposing the hose to possible damage. The hose must be long enough to reach the work area with enough extra length to allow free movement while working. 3. Secure loose workpieces using a vise or clamps (not included) to prevent movement while working. 4. There must not be hazardous objects (such as utility lines or foreign objects) nearby that will present a hazard while working. MAINTENANcE Page 10 For technical questions, please call 1-888-866-5797. Item 63061 62835 2. Connect the air hose to the air inlet of the tool. 3. Push and snap socket (not included) onto the Anvil. 4. To tighten, set the Regulator Knob to one of the three Forward torque settings. 5. Place the socket over the nut you wish to tighten. 6. Hold the Handle firmly and place other hand on top of Housing. Then gently squeeze the Trigger. 7. To loosen, set the Regulator Knob to the Reverse setting. 8. Place socket over desired nut, hold Handle firmly and gently squeeze the Trigger. 9. If the tool requires more force to accomplish the task, verify that the tool receives sufficient, unobstructed airflow (CFM) and increase the pressure (PSI) output of the regulator up to the maximum air pressure rating of this tool. cAUTION! TO pREVENT INJURy FROM TOOL OR AccESSORy FAILURE: Do not exceed the tool's maximum air pressure rating (90 pSI). If the tool still does not have sufficient force at maximum pressure and sufficient airflow, then a larger tool may be required. 10. When the nut is tightened or loosened, release the Trigger. 11. The amount of actual torque may vary depending on the cleanness and condition of the threads and other factors. If tightening critical components, check the actual torque applied to the fastener with a mechanical torque wrench (not supplied). MAINTENANcE OpERATION 12. To prevent accidents, turn off the tool, detach the air supply, safely discharge any residual air pressure in the tool, and release the throttle and/ or turn the switch to its off position after use. Clean external surfaces of the tool with clean, dry cloth, and apply a thin coat of tool oil. Then store the tool indoors out of children's reach. SETUp 1. If an automatic oiler is not used, add a few drops of Pneumatic Tool Oil to the airline connection before use. Add a few drops more after each hour of continual use. SAFETy General Operating Instructions Item 63061 62835 For technical questions, please call 1-888-866-5797. Page 11 User-Maintenance Instructions procedures not specifically explained in this manual must be performed only by a qualified technician. SAFETy TO pREVENT SERIOUS INJURy FROM AccIDENTAL OpERATION: Turn off the tool, detach the air supply, safely discharge any residual air pressure in the tool, and release the throttle and/or turn the switch to its off position before performing any inspection, maintenance, or cleaning procedures. TO pREVENT SERIOUS INJURy FROM TOOL FAILURE: Do not use damaged equipment. If abnormal noise, vibration, or leaking air occurs, have the problem corrected before further use. TO pREVENT SEROUS INJURy FROM EXpLOSION: Lubricate the tool only with specified lubricants. Lubricate the air inlet using only pneumatic tool oil. Other lubricants may damage the mechanism and may be highly flammable, causing an explosion. SETUp cleaning, Maintenance, and Lubrication Note: These procedures are in addition to the regular checks and maintenance explained as part of the regular operation of the air-operated tool. 1. BEFORE EAcH USE, inspect the general condition of the tool. Check for: • loose hardware or housing, • misalignment or binding of moving parts, • cracked or broken parts, and OpERATION • any other condition that may affect its safe operation. 2. Daily - Air Supply Maintenance: Every day, maintain the air supply according to the component manufacturers' instructions. Maintain the lubricator's oil level. Drain the moisture filter regularly. Performing routine air supply maintenance will allow the tool to operate more safely and will also reduce wear on the tool. 3. Weekly - Grease Lubrication: Lubricate the internal mechanism of the tool, using white lithium grease through the grease fittings. 4. Quarterly (every 3 months) – Tool Disassembly, cleaning, and Inspection: Have the internal mechanism cleaned, inspected, and lubricated by a qualified technician. If the vanes need replacement, replace them all as a set. MAINTENANcE Page 12 For technical questions, please call 1-888-866-5797. Item 63061 62835 Troubleshooting 2. Obstructed trigger. 3. Incorrect lubrication or not enough lubrication. 4. Incorrect lubrication or not enough lubrication. 5. Blocked air inlet screen (if equipped). 6. Air leaking from loose housing. 6. Make sure housing is properly assembled and tight. 7. Mechanism contaminated. 7. Have qualified technician clean and lubricate mechanism. Install in-line filter in air supply as stated in Setup: Air Supply. 8. Vane wear or damage. 8. Replace all vanes as set. Severe air leakage. 1. Cross-threaded housing 1. Check for incorrect alignment and uneven gaps. (Slight air leakage components. If cross-threaded, disassemble and is normal, replace damaged parts before use. especially on 2. Loose housing. 2. Tighten housing assembly. older tools.) If housing cannot tighten properly, internal parts may be misaligned. Technician needs to disassemble tool, align parts and reassemble. 3. Damaged valve or housing. 3. Replace damaged components. 4. Dirty, worn or damaged valve. 4. Clean or replace valve assembly. Housing heats 1. Incorrect lubrication or 1. Lubricate using air tool oil during use. not enough lubrication. according to directions. 2. Worn parts. 2. Have qualified technician inspect internal mechanism and replace parts as needed. MAINTENANcE Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect air supply before service. SAFETy Likely Solutions 1. Check for loose connections and make sure that air supply is providing enough air flow (CFM) at required pressure (PSI) to the tool's air inlet. Do not exceed maximum air pressure. 2. Clean around trigger to ensure free movement. 3. Lubricate using air tool oil and grease according to directions. 4. Lubricate using air tool oil according to directions. 5. Clean air inlet screen of buildup. SETUp possible causes OpERATION problem Decreased output. 1. Not enough air pressure and/ or air flow. Item 63061 62835 For technical questions, please call 1-888-866-5797. Page 13 parts List and Diagram pLEASE READ THE FOLLOWING cAREFULLy SAFETy THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO. 62835 parts List and Diagram SETUp part Description Qty part 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Housing Assembly Trigger Assembly O-Ring Trigger Pin Oil Seal Valve Stem Throttle Valve Throttle Valve Spring Exhaust Deflector Air Inlet Washer Ball Bearing Front End Plate Steel Plate 1 1 1 1 1 1 1 1 1 1 1 1 1 1 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Description Rotor Blade Rotor E-Clip Cylinder Dowel Pin Rear End Plate Ball Bearing Gasket O-Ring Regulator Knob Steel Ball Spring O-Ring Cap Qty part 7 1 1 1 1 1 1 1 1 1 1 1 1 1 29 30 31 32 33 34 35 36 37 38 39 40 41 Description O-Ring Screw Hammer Dog Hammer Pin Hammer Cage Anvil Retainer Ring O-Ring Anvil Bushing Gasket Hammer Case O-Ring Grease Port Screw Qty 4 4 2 2 2 1 1 2 1 1 1 1 1 39 OpERATION 38 32 33 34 35 36 37 40 41 31 1 32 29 MAINTENANcE 30 26 27 25 24 23 22 21 20 19 18 16 15 14 13 12 4 17 3 2 5 6 28 7 8 9 10 Page 14 For technical questions, please call 1-888-866-5797. 11 Item 63061 62835 63061 parts List and Diagram Description Qty part 1 1 1 1 1 1 1 1 1 1 1 1 1 1 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Housing Assembly Trigger Assembly O-Ring Trigger Pin Oil Seal Valve Stem Throttle Valve Valve Spring Exhaust Deflector Air Inlet NPT Washer Ball Bearing Front End Plate Steel Washer Description Rotor Blade Rotor E-Clip Cylinder Dowel Pin Rear End Plate Ball Bearing Gasket O-Ring Regulator Knob Steel Ball Spring O-Ring End Cap Qty part 7 1 1 1 1 1 1 1 1 1 1 1 1 1 29 30 31 32 33 34 35 36 37 38 39 40 41 Description Spring Washer Screw Hammer Dog Hammer Pin Hammer Cage Anvil Socket Retainer O-Ring Anvil Bushing Gasket Hammer Case O-Ring Grease Port Screw Qty 4 4 2 2 1 1 1 1 1 1 1 1 1 39 38 32 33 34 35 36 SAFETy 1 2 3 4 5 6 7 8 9 10 11 12 13 14 SETUp part 37 40 41 31 01 16 15 20 19 29 30 26 25 24 23 22 27 14 13 12 18 04 21 17 28 03 02 05 06 07 OpERATION 32 08 09 11 MAINTENANcE 10 Record product's Serial Number Here: Note: If product has no serial number, record month and year of purchase instead. Item 63061 62835 Note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. For technical questions, please call 1-888-866-5797. Page 15 Limited 90 Day Warranty Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper installation, normal wear and tear, or to lack of maintenance. We shall in no event be liable for death, injuries to persons or property, or for incidental, contingent, special or consequential damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclusion may not apply to you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS. To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise. If our inspection verifies the defect, we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will return repaired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. 3491 Mission Oaks Blvd. • pO Box 6009 • camarillo, cA 93011 • 1-888-866-5797
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 16 Producer : Mac OS X 10.9.5 Quartz PDFContext Create Date : 2017:03:03 23:02:25Z Modify Date : 2017:03:03 23:02:25ZEXIF Metadata provided by EXIF.tools