66 6002 Conversion Wiring Diagrams For BC7000L 1000 E1215B
BC7000L1000 to the manual 47a64a3b-8d20-47b7-8368-9bb30baf5840
User Manual: E1215B
Open the PDF directly: View PDF .
Page Count: 33
Download | |
Open PDF In Browser | View PDF |
CONVERSION WIRING DIAGRAMS FOR BC7000L1000 The diagrams and instructions contained in this booklet are for converting the following model programmers to BC7000 Microcomputer Based Burner Control System. TABLE OF CONTENTS Page Section l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...2 Fireye C, D, and E-Series Section II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...6 Fireye P-Series Section III . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Honeywell R4126, R4127, R4181 Section lV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Honeywell R4140, R4150 with 20 Terminal Subbase (120 V only) Section V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...29 Honeywell R4150 with 13 or 15 Terminal Subbase 1. Installer must be a trained, experienced, flame safeguard control service technician. 2. Disconnect power supply before beginning installation to prevent electrical shock and equipment damage. 3. All wiring must comply with applicable local electrical codes, ordinances, and regulations. 4. Voltage and frequency of the power supply and flame detector(s) connected to this control must agree with those marked on the device. 5. Loads connected to the control terminals must not exceed those listed in the SPECIFICATIONS section. 6. All external timers must be listed or component recognized by authorities having jurisdiction, for the specific purpose for which they are used. 7. Perform all required checkout tests after installation is complete. IMPORTANT For on-off, gas-fired systems, some authorities having jurisdiction prohibit the wiring of any limit or operating contacts in series with the main fuel valve(s). P.G. Rev. 6/89 Form Number 66-6002—4 ©Honeywell Inc. 1989 SECTION I FIREYE C, D, E-SERIES CONTROL 120 V ONLY DIRECTIONS: 1. Disconnect all power to programmer. 2. Remove old programmer from subbase (trade-in to Honeywell Authorized Flame Safeguard Distributor). 3. Mark all wires on subbase; i.e., wires connected to terminal “D” should be marked “D.” Disconnect wires as they are marked. 4. Remove old subbase. 5. Mount Q520A subbase. 6. Connect wires to subbase per attached cross reference. Pay close attention to footnotes. For example: To convert a Fireye 70D10 to a BC7000, the wire marked “P” would connect to terminal #3 on the Q520. The wire marked “8” would connect to Q520 terminal #15. 7. The symbol “ “ designates a footnote. Study these footnotes carefully. 8. Plug in the BC7000. Make sure you select the proper amplifier, detector and program module for the application. FIREYE 70D10/26CF6-5022/26 CU6-5065 EP160/EP161/EP170 TO E1214A BC7000L/PM720L2004 or 1030 FIREYE 24CJ5 - 5010/5011/3010/3011 25CU6 5062/5063/RS-2E 70D30/26CF6 5020/5021/1010/1011 EP380/EP381/EP390 E1215B TO BC7000L/PM720M2002 FIREYE 24CJ5 5015 70D20/26CF6 5023/25 CU65055 EP260/EP261/EP270 E1216E TO BC7000L/PM720G2005 SECTION II FIREYE P-SERIES CONTROLS 120 V ONLY DIRECTIONS: 1. Disconnect all power to programmer. 2. Remove old programmer from subbase (trade-in to Honeywell Authorized Flame Safeguard Distributor). 3. Mark all wires on subbase; i.e., wires connected to terminal “D” should be marked “D.” Disconnect wires as they are marked. 4. Remove old subbase. 5. Mount Q520A subbase. 6. Connect wires to subbase per attached cross reference. Pay close attention to footnotes. For example: To convert a Fireye 26RJ81016 to a BC7000, the wire marked “B” would connect to terminal #10 on the Q520. The wire marked “W” would connect to Q520 terminal #14. 7. The symbol “ “ designates a footnote. Study these footnotes carefully. 8. Plug in the BC7000. Make sure you select the proper amplifier, detector and program module for the application. 6 FIREYE 26RJ8 1016, 1016T 26RJ8 1012, 1012T, 6012, 6012T E1221A TO BC7000L + PM720G2005 FIREYE 25RLJ84580 TO E1693 BC700L + PM720L1030 FIREYE 25RU8 6560, 6570,6580 26RJ8 6060, 6070,6080, 6160 TO E1217B BC7000L + PM720L1030 FIREYE 29RF5 1001, 1009, 6009 TO E1218A BC7000L + PM720G2013 26RJ8 6058, 6066, 6068 25RU8 6558, 6566 TO E1219A BC7000L + PM720G2005 FIREYE 26RJ8 1002, 1003, 1008, 1011, 1018, 6008, 6018 29RF5 1000, 1002, 1005, 1015, 1104 29RF5 6015 E1220A TO BC7000L + PM720G2005 SECTION Ill HONEYWELL R4126, R4127, R4181 CONTROLS 120 V ONLY DIRECTIONS: 1. Disconnect all power to programmer. 2. Remove old programmer from subbase (trade-in to Honeywell Authorized Flame Safeguard Distributor). 3. Mark all wires on subbase; i.e., wires connected to terminal “D” should be marked “D.” Disconnect wires as they are marked. 4. Remove old subbase. 5. Mount Q520A subbase. 6. Connect wires to subbase per attached cross reference. Pay close attention to footnotes. For example: To convert an R4126A1172 to a BC7000, the wire marked “F2” would connect to terminal #3 on the Q520. The wire marked “3” would connect to Q520 terminal #14. 7. The symbol “ ” designates a footnote. Study these footnotes carefully. 8. Plug in the BC7000. Make sure you select the proper amplifier, detector and program module for the application. 13 R4126A1172, 1180,1198 TO E1222A BC7000L + PM720L2004 R4126A1008, 1016, 1024, 1032, 1040, 1057, 1081, 1149 R4126B1006, 1014, 1022 E1223A TO BC7000L + PM720G2005 R4126A1073,1164 TO E1224A BC7000L + PM720L2004 R4127A1155 AND R4127A1197 TO E1753 BC7000L + PM720G2005 R4127 (ALL MODELS) EXCEPT R4127A1171, R4127A1155, R4127A1197, R4127B1039, AND R4127B1047 E1225A TO BC7000L + PM720G R4127A1171/R4127B1039/R4127B1047 E1724A TO BC7000L+PM720G2005 R4181A1000, R4181A1026 TO E1226A BC7000L + PM720G2005 R4181A1018, R4181A1034 TO E1227A BC7000L + PM720L2004 R4181A1042, R4181A1059 TO E1228A BC7000L + PM720L2004 SECTION IV HONEYWELL R4140 AND R4150, 20 TERMINAL SUBBASE 120 V ONLY NOTE: This cross reference does not include conversions for proprietary controls such as Cleaver Brooks, Vapor or Peabody Gordon Piatt models. Preignition Interlock Models: R4140G1007 R4140G1015 R4140G1106 R4140G1130 R4140G1148 R4140L All Models R4140M1145 R4140M1152 R4140M1160 R4140M1 178 R4150G1186 R4150L All Models All others have start interlocks. If existing R4150 has 13- or 15-terminal subbase, the subbase must be replaced with a 20 terminal Q520A. See Section V. 23 REPLACING AN R4140M OR R4150M WITH START INTERLOCKS WITH A BC7000L/PM720M2002 *-X xx ;.-” .“. STEPS FOR CONVERSION 1. START INTERLOCKS BECOME PREIGNITION INTERLOCKS. 2. DISCONNECT DAMPER CONTROL WIRE FROM TERMINAL 10 CONNECT IT TO TERMINAL 11. 3. REMOVE JUMPER FROM TERMINAL BETWEEN TERMINAL 11 AND 12 (on some models). 4. IF LOW FIRE SWITCH IS NOT USED, CONNECT JUMPER WIRE BETWEEN TERMINALS 8 AND 13. 5. JUMPER 8 TO 15 FOR 30-SECOND PREPURGE. 6. IF OLD CONTROL HAD 12 TO 11 JUMPERED, ADD A JUMPER FROM 12 TO 16. E1235B REPLACING AN R4140M OR R4150M WITH PREIGNITION INTERLOCKS WITH A BC7000L/PM720M2002 E1237 2. DISCONNECT DAMPER CONTROL WIRE FROM TERMINAL 10 AND CONNECT IT TO TERMINAL 11. 3. REMOVE JUMPER FROM TERMINAL BETWEEN TERMINAL 11 AND 12 (on some models). 4. IF LOW FIRE SWITCH IS NOT USED, CONNECT JUMPER WIRE BETWEEN TERMINALS 8 AND 13. 5. JUMPER TERMINALS 8 TO 15 FOR 30-SECOND PURGE. E1237 REPLACING AN R4140G OR R4150G WITH START INTERLOCKS WITH A BC7000L/PM720G2005 /PM720G2013 t * ----1..-“ BC7000L/PM720G2005 /PM720G2013 STEPS FOR CONVERSION 1. START INTERLOCKS BECOME PREIGNITION INTERLOCKS. 2. FOR PM720G2005 ONLY JUMPER 15 TO 8 FOR 30-SECOND TRIAL FOR MAIN FLAME AT TERMINAL NO. 6. 3. TERMINAL 16 MUST BE USED ON THE BC7000. IF AN EXTERNAL TIE POINT WAS PREVIOUSLY USED ON THE R4140G OR R4150G TO BE REPLACED, IT MUST BE LOCATED AND WIRED TO TERMINAL NO. 16. 4. FOR INTERMITTENT PILOT USE PM720G2013. 26 E1234 REPLACING AN R4140G OR R4150G WITH PREIGNITION INTERLOCKS WITH A BC7000L/PM720G2005 /PM720G2013 #f-----+--- -., ,,, E.,li:,. ,):.> ?>., ~ FOR PM720G20050NLYJ”MPER8T0 MAIN AT TERMINAL 6. 15 FOR3CISECCZNDTRIAL ( +- ————=—=— —$==$ — Ji >: c, . /+—’——— ———=— . J FOR BC7000L/PM720G2005 /PM720G2013 STEPS FOR CO NVERSIO~ 1. IDENTIFY AND REMOVE BURNER CONTROLLER AND LIMITS CIRCUIT WIRE FROM TERMINAL NO. 4 ON THE Q520A SUBBASE AND CONNECT TO TERMINAL NO. 16. 2. FOR PM720G2005 ONLY, JUMPER 8 TO 15 FOR 30-SECOND TRIAL FOR MAIN FLAME AT TERMINAL 6. 3. FOR INTERMITTENT PILOT USE PM720G2013. 27 El 233 REPLACING AN R4140L OR R4150L WITH A BC7000L/PM720L1030 /PM720L2004 2- /-. , L -T ‘-4 ~VJIRllUG CHANGE NOT NECESSARY FOR PM720LI030 BC7000L/PM720L1030 /PM720L2004 STEPS FOR CONVERSION 1. IDENTIFY AND REMOVE BURNER CONTROLLER AND LIMITS CIRCUIT WIRE FROM TERMINAL NO. 4 ON THE Q520A ~ SUBBASE AND CONNECT TO TERMINAL NO. 16. 2. IDENTIFY AND REMOVE HIGH FIRE PROVING SWITCH WIRES FROM TERMINAL NO, 8 AND CONNECT THEM TO TERMINAL L1 . (THE LOW FIRE SWITCH WIRE MAY BE CONNECTED TO TERMINAL NO. 15. REMOVE FROM TERMINAL NO. 15 AND CONNECT TO 8.) 3. FOR ENERGY SAVING PREPURGE USE PM720L2004. 28 E1236A SECTION V REPLACING R4150 MODELS WITH 13- OR 15-TERMINAL SUBBASES 1. Disconnect all power to programmer. 2. Remove R4150 from subbase (trade-in to Authorized Distributor). 3. Mark all wires on subbase; i.e., wires connected to terminal “9” should be marked “9”. Disconnect wires as they are marked. 4. Remove old subbase. 5. Install 20-terminal Q520A subbase. 6. Connect wires to subbase per attached cross reference. Pay close attention to footnotes. 7, Plug in the BC7000. Make sure you select the proper amplifier detector and program module for the application. 29 CONVERSION FOR R4150A, B, AND C MODELS 120 VOLT ONLY USE BC7000L/PM720M2002 E1229A CONVERSION FOR R4150G1004, G1020, G1046, G1103, G1111, G1145, G1178 MODELS 120 VOLT ONLY USE BC7000L/PM720G2013 E1230A CONVERSION FOR R4150G1012 AND G1079 MODELS 120 VOLT ONLY USE BC7000L/PM720M2002 E1231A CONVERSION FOR R4150M USE BC7000L/PM720M2002 E1232A
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Assemble, Print high-res XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 1996:05:30 15:27:08Z Creator Tool : pumb075.tmp Modify Date : 2007:05:07 14:14:14-05:00 Metadata Date : 2007:05:07 14:14:14-05:00 Format : application/pdf Description : Conversion Wiring Diagrams for BC7000L 1000 Creator : H&BC Technical Communications Title : 66-6002 - Conversion Wiring Diagrams for BC7000L 1000 Keywords : Producer : Acrobat PDFWriter 2.01 for Windows Document ID : uuid:c3948d60-58de-4f94-9f71-5367c780ed96 Instance ID : uuid:520d3500-d3a1-48a1-bfec-ba091dbe2a8a Page Count : 33 Subject : Conversion Wiring Diagrams for BC7000L 1000 Author : H&BC Technical CommunicationsEXIF Metadata provided by EXIF.tools