Manual For The 69675 212cc, 4000 Watts Max/3200 Rated Portable Generator Certified California

User Manual: Manual for the 69675 212cc, 4000 Watts Max/3200 Watts Rated Portable Generator - Certified for California 4000 Max Starting/3200 Running Watts, 6.5 HP (212cc) Generator CARB

Open the PDF directly: View PDF PDF.
Page Count: 24

DownloadManual For The 69675 212cc, 4000 Watts Max/3200 Rated Portable Generator - Certified California
Open PDF In BrowserView PDF
Owner’s Manual & Safety Instructions
Save This Manual Keep this manual for the safety warnings and precautions, assembly,

operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the
back of the manual near the assembly diagram (or month and year of purchase if product has no number).
Keep this manual and the receipt in a safe and dry place for future reference.

REV 16g

Using a generator indoors CAN KILL YOU
IN MINUTES.
Generator exhaust contains carbon
monoxide. This is a poison you cannot see
or smell.

NEVER use inside
a home or garage,
EVEN IF doors and
windows are open.

Only use OUTSIDE
and far away from
windows, doors,
and vents.

Visit our website at: http://www.harborfreight.com
Email our technical support at:
productsupport@harborfreight.com
Email our Engine support at: predator@harborfreight.com

When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-888-866-5797 as soon as possible.
Copyright© 2012 by Harbor Freight Tools®. All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.

Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.

Table of Contents
Safety.......................................................... 2

Maintenance............................................... 14

Setup........................................................... 6

Parts List and Diagram............................... 19

Specifications.............................................. 6

Warranty..................................................... 23

Safety

Operation..................................................... 8

WARNING SYMBOLS AND DEFINITIONS
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that
follow this symbol to avoid possible injury or death.
Indicates a hazardous situation which, if not avoided,
will result in death or serious injury.

Setup

Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.

Addresses practices not related to personal injury.

IMPORTANT SAFETY INSTRUCTIONS
Operation

INSTRUCTIONS PERTAINING TO A RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS
WARNING – When using tools, basic precautions should always be followed, including the following:

Set up Precautions
1. Gasoline fuel and fumes are flammable,
and potentially explosive. Use proper fuel
storage and handling procedures. Do not store
fuel or other flammable materials nearby.

Maintenance

2. Have multiple ABC class fire
extinguishers nearby.
3. Operation of this equipment may create sparks
that can start fires around dry vegetation. A
spark arrestor may be required. The operator
should contact local fire agencies for laws or
regulations relating to fire prevention requirements.
4. Set up and use only on a flat, level,
well‑ventilated surface.

Page 2

5. All connections and conduits from the
Generator to the load must only be installed
by trained and licensed electricians, and
in compliance with all relevant local, state,
and federal electrical codes and standards,
and other regulations where applicable.
6. Connections for standby power to a building
electrical system must be made by a qualified
electrician. The connection must isolate the
generator power from utility power, and must comply
with all applicable laws and electrical codes.
7. Wear ANSI-approved safety goggles,
heavy-duty work gloves, and dust
mask/respirator during set up.

For technical questions, please call 1-888-866-5797.

ITEM 69675

8. Use only lubricants and fuel
recommended in this manual.
9. Improper connections to a building electrical
system can allow electrical current from the
generator to backfeed into the utility lines. Such
backfeed may electrocute utility company workers
or others who contact the lines during a power
outage, and the generator may explode, burn, or
cause fires when utility power is restored. Consult
the utility company and a qualified electrician if
intending to use the generator for back up power.

10. Do not operate the Generator before grounding.
The Generator must be earth-grounded
in accordance with all relevant electrical
codes and standards before operation.

Safety

Set up Precautions (cont.)

Operating Precautions

8. Do not touch engine during use. Let engine
cool down before service or storage.
9. Never store fuel or other flammable
materials near the engine.
10. If the plugged in product operates abnormally
or unusually slow, immediately stop using the
generator as a power source. Always read and
adhere to the instruction manual of the product
to be powered, to make sure that it can be safely
and efficiently powered by a portable generator.
11. Before connecting an appliance or power
cord to the generator: Make sure that it is in
good working order. Faulty appliances or power
cords can create a potential for electrical shock.

Only use OUTSIDE and far away from windows,
doors, and vents.
2. Never use a generator indoors, including in
garages, basements, crawl spaces and sheds.
Opening doors and windows or using fans will NOT
prevent carbon monoxide build up in the home.
3. When using generators, keep them outdoors
and far away from open doors, windows,
and vents to avoid toxic levels of carbon
monoxide from building up indoors.
4. If you start to feel sick, dizzy, or weak while
using a generator, get to fresh air right away.
The carbon monoxide from generators can
quickly lead to full incapacitation and death.
5. Keep children away from the equipment,
especially while it is operating.
6. Keep all spectators at least six feet
from the Engine during operation.
ITEM 69675

12. Do not exceed the maximum power rating of
the generator. Make sure that the total electrical
rating of the all of the tools or appliances plugged
into the generator at the same time does not
exceed that of the generator. Check that the startup
surge will not be beyond the limit of the Generator.
Power levels between rated and maximum
may be used for no more than 30 minutes.
13. Avoid substantially overloading which will
trip the circuit breaker. Exceeding the time
limit for maximum power operation or slightly
overloading the generator may not switch the
circuit breaker or circuit protector OFF, but will
shorten the service life of the generator.
14. Do not attempt to connect or disconnect
load connections while standing in
water, or on wet or soggy ground.
15. Do not touch electrically energized parts of
the Generator and interconnecting cables
or conductors with any part of the body, or
with any non-insulated conductive object.

For technical questions, please call 1-888-866-5797.

Page 3

Operation

NEVER use inside a home or garage, EVEN IF
doors and windows are open.

Setup

7. Fire Hazard! Do not fill gas tank while engine
is running. Do not operate if gasoline has been
spilled. Clean spilled gasoline before starting engine.
Do not operate near pilot light or open flame.

Maintenance

CARBON MONOXIDE HAZARD
Using a generator indoors CAN KILL
YOU IN MINUTES.
Generator exhaust contains carbon
monoxide. This is a poison you cannot
see or smell.

1.

Operating Precautions (cont.)

Safety

16. Connect the Generator only to a load or
electrical system (120 volt or 240 volt) that is
compatible with the electrical characteristics
and rated capacities of the Generator.
17. Insulate all connections and disconnected wires.

29. Stay alert, watch what you are doing
and use common sense when operating
this piece of equipment. Do not use this
piece of equipment while tired or under the
influence of drugs, alcohol or medication.

18. Guard against electric shock. Prevent
body contact with grounded surfaces such as
pipes, radiators, ranges, and refrigerators.

30. Dress properly. Do not wear loose clothing or
jewelry. Keep hair, clothing and gloves away
from moving parts. Loose clothes, jewelry or
long hair can be caught in moving parts.

19. Only use a suitable means of transport and
lifting devices with sufficient weight bearing
capacity when transporting the generator.

31. Parts, especially exhaust system components,
get very hot during use. Stay clear of hot parts.

20. Secure the Generator on transport vehicles to
prevent the tool from rolling, slipping, and tilting.
21. Industrial applications must
follow OSHA requirements.

Setup

22. Do not leave the Generator unattended when it is
running. Turn off the Generator (and remove safety
keys, if available) before leaving the work area.
23. The Generator engine can produce high
noise levels. Prolonged exposure to noise levels
above 85 dBA is hazardous to hearing. Always
wear ear protection when operating or working
around the gas engine while it is operating.
24. Wear ANSI-approved safety glasses and
hearing protection during use.

Operation

25. People with pacemakers should consult their
physician(s) before use. Electromagnetic
fields in close proximity to a heart pacemaker
could cause pacemaker interference or
pacemaker failure. Caution is necessary when
near the engine’s magneto or recoil starter.
26. Use only accessories that are recommended
by Harbor Freight Tools for your model.
Accessories that may be suitable for one
piece of equipment may become hazardous
when used on another piece of equipment.
27. Do not operate in explosive atmospheres,
such as in the presence of flammable
liquids, gases, or dust. Gasoline-powered
engines may ignite the dust or fumes.

Maintenance

28. Keep grounded conductive objects, such as
tools, away from exposed, live electrical parts
and connections to avoid sparking or arcing.
These events could ignite fumes or vapors.

Page 4

32. Do not cover the generator or its
engine during operation.
33. Keep the generator, its engine, and
surrounding area clean at all times.
34. Use the generator, accessories, etc., in
accordance with these instructions and in
the manner intended for the particular type of
equipment, taking into account the working
conditions and the work to be performed. Use
of the equipment for operations different from those
intended could result in a hazardous situation.
35. Do not operate the generator with known
leaks in the engine’s fuel system.
36. WARNING: This product contains or, when
used, produces a chemical known to the State
of California to cause cancer and birth defects
or other reproductive harm. (California Health
& Safety Code § 25249.5, et seq.)
37. When spills of fuel or oil occur, they must
be cleaned up immediately. Dispose of fluids
and cleaning materials as per any local, state, or
federal codes and regulations. Store oil rags in
a bottom-ventilated, covered, metal container.
38. Keep hands and feet away from
moving parts. Do not reach over or
across generator while operating.
39. Before use, check for misalignment or binding
of moving parts, breakage of parts, and any
other condition that may affect the generator’s
operation. If damaged, have the generator
serviced before using. Many accidents are
caused by poorly maintained equipment.
40. Use the correct generator for the
application. Do not modify the generator
or its engine, and do not use the generator
for a purpose for which it is not intended.

For technical questions, please call 1-888-866-5797.

ITEM 69675

b. Turn the engine switch to its “OFF” position.
c. Allow the engine to completely cool.
d. Then, remove the spark plug
cap from the spark plug.
2. Keep all safety guards in place and in
proper working order. Safety guards include
muffler, air cleaner, mechanical guards,
and heat shields, among other guards.
3. Keep all electrical equipment clean and
dry. Replace any wiring where the insulation is
cracked, cut, abraded, or otherwise degraded.
Replace terminals that are worn, discolored, or
corroded. Keep terminals clean and tight.
4. Do not alter or adjust any part of the
equipment or its engine that is sealed by the
manufacturer or distributor. Only a qualified
service technician may adjust parts that may
increase or decrease governed engine speed.
5. Wear ANSI-approved safety goggles,
heavy-duty work gloves, and dust
mask/respirator during service.
6. Maintain labels and nameplates on
the equipment. These carry important
information. If unreadable or missing, contact
Harbor Freight Tools for a replacement.

8. Store equipment out of the reach of children.
9. Follow scheduled engine and
equipment maintenance.
Refueling:
1. Do not smoke, or allow sparks, flames,
or other sources of ignition around the
equipment, especially when refuelling.
2. Do not refill the fuel tank while the
engine is running or hot.
3. TO PREVENT FUEL LEAKAGE AND FIRE
HAZARD, Do not overfill with fuel. Fill with
fuel according to the Fuel Level information
below the Specification chart for your model.

Setup

a. Unplug all devices from the generator.

7. Have the equipment serviced by a qualified
repair person using only identical replacement
parts. This will ensure that the safety of the
equipment is maintained. Do not attempt any
service or maintenance procedures not explained in
this manual or any procedures that you are uncertain
about your ability to perform safely or correctly.

4. Do not fill fuel tank to the top. Leave a little
room for the fuel to expand as needed.
5. Refuel in a well-ventilated area only.
6. Wipe up any spilled fuel and allow excess
to evaporate before starting engine. To
prevent FIRE, do not start the engine
while the smell of fuel hangs in the air.

Operation

1. Before service, maintenance, or cleaning:

Safety

Service Precautions

Maintenance

SAVE THESE INSTRUCTIONS.

ITEM 69675

For technical questions, please call 1-888-866-5797.

Page 5

Functional Description

Specifications
Safety

Output
Generator

Phase
Electrical Receptacle
Displacement
Engine Type
Cooling System

Engine

Type
Capacity

Fuel
Engine Oil

Type SAE

Setup

Capacity
Run Time @ 50% load
Operational Volume
Available accessories

120/240VAC, 60Hz
3,200 Running Watts (4,000 Peak Watts)
Single
Two 3-Prong, duplex NEMA #5-20 120V
One 4-Prong, NEMA #L14-30 twistlock 120V/240V
One DC Outlet 12VDC
212cc
Horizontal Single Cylinder 4 stroke OHV
EPA phase III compliant
Forced air cooled
87+ octane stabilizer treated unleaded gasoline
4 Gallons (15L)
10W-30 above 32° F
5W-30 at 32° F or below
.6 Quart (.6L)
10 hr.
72 dB
Wheel kit (sold separately)

The emission control system for this Generator’s Engine is warranted for standards set by the U.S. Environmental
Protection Agency and by the California Air Resources Board (also known as CARB). For warranty information,
refer to the last pages of this manual.

Components and Controls
DC Receptacle
DC Circuit Breaker

Fuel Cap

Operation

AC Circuit Breaker

Fuel Valve

Choke

AC Receptacles

Air Filter

Maintenance

Frame
Ground Terminal
Starter
Handle

Power Switch
Low Oil Indicator

Page 6

For technical questions, please call 1-888-866-5797.

ITEM 69675

Components and Controls (cont.)

I
O
1. Engine Switch: Used to enable/disable Generator
operation.

ON
OFF

3. Circuit Breakers: The circuit breaker protects
the Generator from overloading. The rating of the
breaker and the load it protects are marked near
the breaker. Should any of the Circuit Breakers trip,
the Generator will stop the electricity output. If this
happens, unplug all loads from the Generator. Allow
the Generator to cool down. Then, press the tripped
Circuit Breaker, restart the Engine, and re-attach
loads.

Safety

The following are descriptions of the controls
on the power panel. Your generator has
sockets to power your products with circuit
breakers to protect the voltage flow.

2. AC Receptacles: The Generator contains several
AC Receptacles to power tools and equipment.

a. 3-Prong, duplex
120 volt AC Receptacle
(NEMA #5-20)

Setup

4. DC Outlet Receptacle: 12 VDC outlet receptacle
set provides a power source for 12 volt DC items.

5. Grounding Terminal: Prior to each use, set
up the ground wire (not included) connection
to the Grounding Terminal to properly ground
the Generator. See Set up instructions
to properly ground the Generator.

Operation

b. 4-Prong, twistlock
120/240 volt AC Receptacle
(NEMA #L14-30)

Maintenance

WARNING! Connect tools and equipment
only to the AC Receptacle that is compatible with
the electrical characteristics and rated capacities
of the tools and equipment being used.

ITEM 69675

For technical questions, please call 1-888-866-5797.

Page 7

Initial Tool Set Up/Assembly
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.

Safety

TO PREVENT SERIOUS INJURY:
Operate only with proper spark arrestor installed.
Operation of this equipment may create sparks that can start fires around dry vegetation.
A spark arrestor may be required. The operator should contact local fire agencies
for laws or regulations relating to fire prevention requirements.

Grounding
The Generator must be properly grounded before use. Have the unit grounded
by a qualified electrician if you are not qualified to do so.

Setup

To ground the Generator, connect a #6 AWG grounding wire (not included) from the
Grounding Terminal on the Control Panel to a grounding rod (not included) that has been
driven at least 24 inches deep into the earth. The grounding rod must be an earth-driven
copper or brass rod (electrode) which can adequately ground the Generator.
NOTICE: This generator is not intended to power sensitive electronic equipment without the addition of an
appropriate line conditioner and surge protector (both not included). Sensitive electronic equipment includes,
but is not limited to, audio/video equipment, some television sets, computers, and printers. Sensitive
electronic equipment should be operated on approved inverter type generators or pure sine wave generators.
Note: For additional information regarding the parts listed in the following pages,
refer to the Assembly Diagram near the end of this manual.
Note: Wheel Kit, item # 68531 (sold separately) can be used with this generator.

Operation

Operating Instructions
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
Inspect tool before use, looking for damaged, loose, and missing parts.
If any problems are found, do not use tool until repaired.

Generator Pre-Start Checks
Inspect engine and equipment, looking for damaged, loose, and missing parts before set up and starting.
If any problems are found, do not use equipment until fixed properly.

Maintenance

Checking and Filling Engine Oil

1. Make sure the engine is stopped and is level.

CAUTION! Your Warranty is VOID if the engine’s
crankcase is not properly filled with oil before each
use.
Before each use, check the oil level. Do not run the
engine with low or no engine oil.
Running the engine with no or low engine oil
WILL permanently damage the engine.

2. Close the Fuel Valve.

Page 8

3. Clean the top of the Dipstick and the
area around it. Remove the Dipstick
by threading it counterclockwise, and
wipe it off with a clean lint free rag.

For technical questions, please call 1-888-866-5797.

ITEM 69675

Full level

4. Reinsert the Dipstick without threading it in and
remove it to check the oil level. The oil level
should be up to the full level as shown above.
5. If the oil level is at or below the low mark add the
appropriate type of oil until the oil level is at the
proper level. SAE 10W‑30 oil is recommended
for general use. (The SAE Viscosity Grade chart
on page in the Service section shows other
viscosities to use in different average temperatures.)
6. Thread the dipstick back in clockwise.
CAUTION! Do not run the engine with too little oil.
The engine will be permanently damaged.

WARNING! TO PREVENT SERIOUS
INJURY FROM FIRE:
Fill the fuel tank in a well-ventilated area
away from ignition sources. If the engine is
hot from use, shut the engine off and wait
for it to cool before adding fuel.
Do not smoke.
1. Clean the Fuel Cap and the area around it.
2. Unscrew and remove the Fuel Cap.
3. If needed, fill the Fuel Tank to about 1 inch under
the fill neck of the Fuel Tank with 87 octane or
higher stabilizer-treated unleaded gasoline.
Note: Do not use gasoline containing more than
10% ethanol (E10). Do not use E85 ethanol.
Note: Do not use gasoline that has been stored in a
metal fuel container or a dirty fuel container. It can
cause particles to enter the carburetor, effecting
engine performance and/or causing damage.

Setup

Full level

Safety

Checking and Filling Fuel

4. Then, replace the Fuel Cap.
5. Wipe up any spilled fuel and allow excess
to evaporate before starting engine.
To prevent FIRE, do not start the engine
while the smell of fuel hangs in the air.

Before starting the engine:
a. Follow the Set Up Instructions
to prepare the Generator.
b. Unplug all loads from the Generator.
c. Inspect the Generator and engine.
d. Fill the engine with the proper
amount and type of both
stabilizer-treated fuel and oil.
Basic Generator Use Procedure
See following pages for specific instructions
1. Check that the generator can handle the
wattage needed to power your products.
2. Start the Engine, and allow the Engine and
Generator to run and warm up for five minutes
after starting with no electrical load.
3. Plug in products.
4. When finished using the Generator,
disconnect all electrical loads.
Note: Do not allow generator to run
out of fuel with loads attached.

ITEM 69675

5. Turn off the Engine.
6. Allow the Generator and its Engine to
completely cool. Then store the unit in a
clean, dry, safe location out of reach of
children and other unauthorized people.
IMPORTANT: After starting the engine, allow it to
run at no load for five minutes with no load after
each start‑up so that the engine can stabilize.
7. Break-in Period:
a. Breaking-in the engine will help to ensure
proper equipment and engine operation.
b. The operational break-in period will last
about 3 hours of use. During this period:
• Do not apply a heavy load to the equipment.
c. The maintenance break-in period will last
about 20 hours of use. After this period:
• Change the engine oil.
Under normal operating conditions
subsequent maintenance follows the schedule
explained in the SERVICE section.

For technical questions, please call 1-888-866-5797.

Page 9

Maintenance

Before Starting the Generator Engine

Operation

Using the Generator

Starting the Engine

Safety

1. To start a cold engine, move the Choke to the
START position.
To restart a warm engine, leave the Choke in the
RUN position.

START

RUN

2. Open the Fuel Valve.

Setup

OFF

ON

3. Turn the Engine Switch to ON.
I

ON

O

Operation

4. Grip the Starter Handle of the Engine loosely and pull it
slowly several times to allow the gasoline to flow into
the Engine’s carburetor. Then pull the Starter Handle
gently until resistance is felt. Allow Cable to retract fully
and then pull it quickly. Repeat until the engine starts.
Note: Do not let the Starter Handle snap back against
the engine. Hold it as it recoils so it doesn’t hit
the engine.

Maintenance

5. Allow the Engine to run for several seconds.
Then, if the Choke lever is in the START position,
move the Choke Lever very slowly to its RUN position.

NOTE: Moving the Choke Lever too fast could stall the engine.

START

RUN

IMPORTANT: Allow the engine to run at no load for five minutes with no
load after each start‑up so that the engine can stabilize.

Page 10

For technical questions, please call 1-888-866-5797.

ITEM 69675

Connecting Electrical Loads
Familiarize yourself with the engine controls, power panel and how to start the engine before using the
generator. Calculate the wattage of the products you will use with the generator and verify that the generator
0
1,00 0
can handle the total load.
0
WARNING! Connect only properly wired plugs to the generator.
A plug that is spliced onto a different cord may be hazardous.
Only a qualified electrician should wire a plug onto a cord.
CAUTION Never exceed the rated capacity for this Generator,
as serious damage to the Generator and/or appliances, tools, and
equipment could result from an overload. Starting and running
wattage requirements should always be calculated when matching this
Generator’s wattage capacity to the appliance, tool, or equipment.

0)

4

200
600

)
)
600

Safety

t

200
600
0
2,80

,
tts 2
Wa )
ing 3,200
n
n
u
tts
an
a l R th
Wa s
Tot e less t-up
d
loa 0)
ar
b
t
l
t
l
S
s
0
a
l
(mu itiona d for an 4,0
e
h
d
eed ss t
Ad
est atts n be le
W
st
tup (mu

Use the DC12V Receptacle to power 12VDC equipment.
WARNING! Do not charge batteries without a proper charge controller. Do not overcharge.
a. Connect the items that require the most wattage first.

c. Connect any lights next.
d. Voltage sensitive appliances, tools, and equipment should be the last to be connected to the Generator.
Plug voltage sensitive items such as TV’s, DVD players, microwaves, and cordless telephones into a UL®
Listed voltage surge protector (not included). Then, connect the surge protector into the Generator.

Setup

b. Connect “inductive” load appliances, tools, and equipment next.
Inductive loads are small hand tools and some small appliances.

IMPORTANT! Failure to connect and operate appliances, tools, and equipment in this sequence can cause
damage to the Generator, appliances, tools, and equipment and will void the Warranty of this Generator.

Operation

NOTE: If Engine speed or voltage fluctuates with a load below the Generator’s running wattage, move the Engine
Choke Lever to the
position.

IF ANY CIRCUIT BREAKERS TRIP CHECK THE FOLLOWING:
1. Make sure that ALL circuit breakers are reset
before starting the generator again.

Evenly distributed
over outlets:

2. Adjust the plugs so the loads are
shared across outlet circuits.

Maintenance

To achieve rated output from the generator,
distribute loads over outlets.

ITEM 69675

For technical questions, please call 1-888-866-5797.

Page 11

Calculating Total Wattage of Devices Used with the Generator

Safety

Before using the Generator, check that the products
you want to plug into the unit are below the rated and
maximum wattage ratings of the Generator. Use the
Wattage Calculation Table below, and the watts listed
on your products, to help calculate multiple
wattage totals.

Wattage Estimate Charts
Note: Wattages listed below are estimates for that type
of equipment only. Check nameplate wattages on all
loads before connecting to Generator.
EMERGENCY

To use the table:

1. Add up the Running Watts for all items you
would like to use at any given time
2. Make sure that this total is under the 3200
running wattage of the generator.
3. Find the single highest starting watts for
the selected items and add to the total.
4. Make sure that this total is under the
4000 peak wattage of the generator.
5. Plug in and turn on products from largest wattage
to smallest.

Setup

Wattage Calculation Table
Running
Watts

Equipment

Running
Watts

Device
Refrigerator/Freezer
Radio

700
100

Additional
Start-up
Watts
1500
0

JOB SITE
Running
Watts

Device
Air Compressor - 1/2 HP
Table Saw - 10"
Belt Sander - 3"
Hand Drill - 1/2"
Halogen Work Light
Recipricating Saw

1000
1700
1200
600
1000
900

Additional
Start-up
Watts
1000
1300
1200
600
0
900

RECREATION
Running
Watts

Device

Total Running Watts
(must be less than 3,200)

AM/FM Radio
Electric Grill
Inflator Pump
CD/DVD Player
Box Fan - 20"
Coffee Maker

100
1700
50
100
200
600

Largest Additional Start-up Watts

HOUSEHOLD

Total Startup Watts needed for all loads
(must be less than 4,000)

Operation

Example
Equipment

Total Running Watts
(must be less than 3,200)
Largest Additional Start-up Watts
Total Startup Watts needed for all loads
(must be less than 4,000)

A generator that is rated more than the minimum
required peak watts will last much longer than a
generator that only supplies the exact watts needed.

Maintenance

To Calculate Wattage
Volts and amps can be multiplied together to get watts (volts x
amps = watts).
To Calculate Additional Start-Up Watts
(If They Are Not Listed)
For equipment with a motor: Use the rated watts
amount as an estimate of additional Start-up Watts.
For most lights or heaters:
there are no additional start-up watts.

Page 12

Running
Watts

Device
Running
Watts

Additional
Start-up
Watts
0
0
100
0
200
0

Computer w/ Monitor
Electric Clothes Dryer
Electric Range
Electric Water Heater
Light Bulb - 100 watts
Microwave - 1000 watts
Sump Pump - 1/2 HP
Television
Washing Machine
Well Pump - 1/2 HP

800
5500
2100
2000
100
1000
1000
400
1100
1000

Additional
Start-up
Watts
0
500
0
0
0
200
1100
0
1100
1000

LAWN & GARDEN
Running
Watts

Device
Hedge Trimmer
Pressure Washer
Lawn Mower
Edger

400
1200
1200
1000

Additional
Start-up
Watts
400
1200
1200
1000

HEATING & COOLING
Device
Central AC - 10,000 BTU
Furnace Fan - 1/2 HP
Space Heater
Window AC - 10,000 BTU

For technical questions, please call 1-888-866-5797.

Running
Watts
1500
900
1800
1200

Additional
Start-up
Watts
1500
1400
0
600

ITEM 69675

Stopping the Engine in an Emergency
To stop the engine in an emergency,
turn the Engine Switch off.

O

Safety

I

NOTICE: Generator shut-off under load may damage
the generator and attached equipment.

OFF

Stopping the Engine Under Normal Conditions

Setup

1. Before turning off the Engine,
turn off all electrical loads,
then unplug them.

2. Turn the Engine Switch off.

I
OFF

Operation

O

3. Close the Fuel Valve.
OFF

Maintenance

ON

ITEM 69675

For technical questions, please call 1-888-866-5797.

Page 13

User‑Maintenance Instructions

Safety

TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Turn the Power Switch of the equipment to its “OFF” position, wait for the engine to cool, and disconnect
the spark plug cap before performing any inspection, maintenance, or cleaning procedures.
TO PREVENT SERIOUS INJURY FROM EQUIPMENT FAILURE:
Do not use damaged equipment. If abnormal noise, vibration, or excess
smoking occurs, have the problem corrected before further use.
Follow all service instructions in this manual. The engine may fail critically if not serviced properly.
Many maintenance procedures, including any not detailed in this manual, will need to be
performed by a qualified technician for safety. If you have any doubts about your ability to safely
service the equipment or engine, have a qualified technician service the equipment instead.

Cleaning, Maintenance, and Lubrication
Setup

Note: This maintenance schedule is intended solely as a general guide. If performance decreases or if
equipment operates unusually, check systems immediately. The maintenance needs of each piece of equipment
will differ depending on factors such as duty cycle, temperature, air quality, fuel quality, and other factors.
Note: The following procedures are in addition to the regular checks and maintenance
explained as part of the regular operation of the engine and equipment.
Before
Each Use

Procedure

Monthly or
Every 3 mo. or Every 6 mo. or
every 20
50 hr. of use 100 hr. of use
hr. of use

Yearly or
every 300
hr. of use

Every
2 Years

Brush off outside of engine
Check engine oil level
Check air cleaner

Operation

Check deposit cup
Change engine oil

*

Clean/replace air cleaner
Check and clean spark plug
1. Check/adjust idle speed
2. Check/adjust valve clearance
3. Clean fuel tank, strainer
and carburetor

**

4. Clean carbon build-up from
combustion chamber
Replace fuel line if necessary

**
**

*Service more frequently when used in dusty areas.
**These items should be serviced by a qualified technician.
Maintenance
Page 14

For technical questions, please call 1-888-866-5797.

ITEM 69675

WARNING! TO PREVENT SERIOUS
INJURY FROM FIRE:
Fill the fuel tank in a well-ventilated area
away from ignition sources. If the engine is
hot from use, shut the engine off and wait
for it to cool before adding fuel.
Do not smoke.
1. Clean the Fuel Cap and the area around it.
2. Unscrew and remove the Fuel Cap.
Note: Do not use gasoline containing more than
10% ethanol (E10). Do not use E85 ethanol.

Note: Do not use gasoline that has been stored in a
metal fuel container or a dirty fuel container. It can
cause particles to enter the carburetor, effecting
engine performance and/or causing damage.
3. If needed, fill the Fuel Tank to about 1 inch
under the fill neck with 87 octane or higher
unleaded gasoline that has been treated with
a fuel stabilizer additive. Follow fuel stabilizer
manufacturer’s recommendations for use.

Safety

Checking and Filling Fuel

4. Replace the Fuel Cap.
5. Wipe up any spilled fuel and allow excess
to evaporate before starting engine. To
prevent FIRE, do not start the engine while
the smell of fuel hangs in the air.

CAUTION! Oil is very hot during operation and can
cause burns. Wait for engine to cool before changing oil.
Full level

Full level

Note: Do not thread
the dipstick in when
checking the oil level.

2. Close the Fuel Valve.
3. Place a drain pan (not included) underneath
the crankcase’s drain plug.
4. Remove the drain plug and, if possible,
tilt the crankcase slightly to help drain
the oil out. Recycle used oil.
5. Replace the drain plug and tighten it.
6. Clean the top of the Dipstick and the
area around it. Remove the Dipstick
by threading it counterclockwise, and
wipe it off with a clean lint free rag.

7. Add the appropriate type of oil until the
oil level is at the full level. SAE 10W‑30
oil is recommended for general use.
The SAE Viscosity Grade chart shows other
viscosities to use in different average temperatures.
SAE Viscosity Grades

8. Thread the
dipstick
back in
clockwise.
CAUTION! Do
not run the
engine with too
little oil. The
engine will be
permanently
damaged.

Operation

1. Make sure the engine is stopped and is level.

Setup

Engine Oil Change

30
10W-30
5W-30
-20

0

20

40

60

80

Average outdoor temperature

100°F

1. Remove the air filter cover and the air filter elements
and check for dirt. Clean as described below.
2. Cleaning:

ITEM 69675

• For “paper” filter elements:
To prevent injury from dust and debris,
wear ANSI-approved safety goggles,
NIOSH‑approved dust mask/respirator, and
heavy-duty work gloves. In a well‑ventilated
area away from bystanders, use pressurized
air to blow dust out of the air filter. If this does
not get the filter clean, replace it.

For technical questions, please call 1-888-866-5797.

Page 15

Maintenance

Air Filter Element Maintenance

Safety

• For foam filter elements:
Wash the element in warm water and
mild detergent several times. Rinse.
Squeeze out excess water and allow it to dry
completely. Soak the filter in lightweight oil
briefly, then squeeze out the excess oil.

3. Install the cleaned filter. Secure the
Air Cleaner Cover before use.

Spark Plug Maintenance
1. Disconnect spark plug cap from end of plug.
Clean out debris from around spark plug.
2. Using a spark plug
wrench, remove
the spark plug.

Spark Plug

Setup

3. Inspect the spark
plug:
If the electrode is
oily, clean it using
a clean, dry rag.
Cylinder
If the electrode
Assembly
has deposits
on it, polish it using emery paper. If the
white insulator is cracked or chipped, the
spark plug needs to be replaced.
NOTICE: Using an incorrect spark plug may
damage the engine. See the Specifications chart
for your Generator for the type and gap required.

4. When installing a new spark plug, adjust
the plug’s gap to the specification on the
Specifications chart. Do not pry against the
electrode, the spark plug can be damaged.
5. Install the new spark plug or the cleaned spark plug
into the engine. Gasket-style: Finger-tighten until
the gasket contacts the cylinder head, then about
1/2-2/3 turn more.
Non-gasket-style: Finger-tighten until the plug
contacts the head, then about 1/16 turn more.
NOTICE: Tighten the spark plug properly.
If loose, the spark plug will cause the engine
to overheat. If overtightened, the threads
in the engine block will be damaged.
6. Apply spark plug boot protector to the end of
the spark plug and reattach the wire securely.

Storage

Operation

When the equipment is to remain idle for longer than
20 days, prepare the Engine for storage as follows:

c. Replace spark plug, but leave
spark plug cap disconnected.

1. CLEANING:
Wait for Engine to cool, then clean Engine with
dry cloth. NOTICE: Do not clean using water.
The water will gradually enter the Engine
and cause rust damage. Apply a thin coat
of rust preventive oil to all metal parts.

d. Pull Starter Handle to distribute oil in cylinder.
Stop after one or two revolutions when you
feel the piston start the compression stroke
(when you start to feel resistance).

2. FUEL:
To protect the fuel tank during storage, fill the
tank with gasoline that has been treated with
a fuel stabilizer additive. Follow fuel stabilizer
manufacturer’s recommendations for use. Refer
to Checking and Filling Fuel on page 9.

Maintenance

WARNING! TO PREVENT SERIOUS
INJURY FROM FIRE:
Fill tank in a well-ventilated area away from
ignition sources. If the engine is hot from
use, shut the engine off and wait for it to
cool before adding fuel. Do not smoke.
3. LUBRICATION:
a. Change engine oil.

4. STORAGE AREA:
Cover and store in a dry, level, well-ventilated
area out of reach of children. Storage area should
also be away from ignition sources, such as
water heaters, clothes dryers, and furnaces.
NOTICE: During extended storage periods the
Engine must be started every 3 months and allowed
to run for 15 – 20 minutes or the Warranty is VOID.
5. AFTER STORAGE:
Before starting the Engine during or after
storage, keep in mind that untreated gasoline
will deteriorate quickly. Drain the fuel
tank and change to fresh fuel if untreated
gasoline has been sitting for a month, if
treated gasoline has been sitting beyond the
fuel stabilizer’s recommended time period,
or if the Engine does not start.

b. Clean out area around spark plug.
Remove spark plug and pour one tablespoon of
engine oil into cylinder through spark plug hole.
Page 16

For technical questions, please call 1-888-866-5797.

ITEM 69675

Troubleshooting
FUEL RELATED:

FUEL RELATED:

1. No fuel in tank or fuel valve closed.

1. Fill fuel tank and open fuel valve.

2. Choke not in START position, cold engine.

2. Move Choke to START position.

3. Gasoline with more than 10% ethanol used. 3. Clean out ethanol rich gasoline from fuel
(E15, E20, E85, etc.)
system. Replace components damaged by
ethanol. Use fresh 87+ octane stabilizertreated unleaded gasoline only.
Do not use gasoline with more than
10% ethanol (E15, E20, E85, etc.).
4. Low quality or deteriorated, old gasoline.

4. Use fresh 87+ octane unleaded gasoline.
Do not use gasoline with more than
10% ethanol (E15, E20, E85, etc.).

5. Carburetor not primed.

5. Pull on Starter Handle to prime.

6. Dirty fuel passageways.

6. Clean out passageways using fuel additive.
Heavy deposits may require further cleaning.

7. Carburetor needle stuck.
Fuel can be smelled in the air.

7. Gently tap side of carburetor float
chamber with screwdriver handle.

8. Too much fuel in chamber. This can be
caused by the carburetor needle sticking.

8. Turn Choke to RUN position. Remove spark
plug and pull the start handle several times
to air out the chamber. Reinstall spark
plug and set Choke to START position.

9. Clogged Fuel Filter.

9. Replace Fuel Filter.

IGNITION (SPARK) RELATED:

IGNITION (SPARK) RELATED:

1. Spark plug cap not connected securely.

1. Connect spark plug cap properly.

2. Spark plug electrode wet or dirty.

2. Clean spark plug.

3. Incorrect spark plug gap.

3. Correct spark plug gap.

4. Spark plug cap broken.

4. Replace spark plug cap.

5. Circuit breaker tripped (electric
start models only).

5. Reset circuit breaker. Check wiring and
starter motor if breaker continues to trip.

6. Incorrect spark timing or
faulty ignition system.

6. Have qualified technician diagnose/
repair ignition system.

COMPRESSION RELATED:

COMPRESSION RELATED:

1. Cylinder not lubricated. Problem after long
storage periods.

1. Pour tablespoon of oil into spark
plug hole. Crank engine a few
times and try to start again.

2. Loose or broken spark plug. (Hissing noise 2. Tighten spark plug. If that does not work,
will occur when trying to start.)
replace spark plug. If problem persists,
may have head gasket problem, see #3.
3. Loose cylinder head or damaged
head gasket. (Hissing noise will
occur when trying to start.)

3. Tighten head. If that does not remedy
problem, replace head gasket.

4. Engine valves or tappets
mis‑adjusted or stuck.

4. Have qualified technician diagnose/
repair ignition system.

ITEM 69675

For technical questions, please call 1-888-866-5797.

Maintenance

Follow all safety precautions whenever diagnosing or servicing the equipment or engine.

Safety

Probable Solutions

Setup

Engine will not start

Possible Causes

Operation

Problem

Page 17

Troubleshooting (cont.)
Problem

Safety

Engine misfires

Setup

Engine stops
suddenly

Engine stops when
under heavy load

Engine knocks

Possible Causes

Probable Solutions

1. Spark plug cap loose.

1. Check wire connections.

2. Incorrect spark plug gap or
damaged spark plug.

2. Re-gap or replace spark plug.

3. Defective spark plug cap.

3. Replace spark plug cap.

4. Old or low quality gasoline.

4. Use only fresh 87+ octane stabilizer-treated
unleaded gasoline.
Do not use gasoline with more than
10% ethanol (E15, E20, E85, etc.).

5. Incorrect compression.

5. Diagnose and repair compression.
(Use Engine will not start:
COMPRESSION RELATED section.)

1. Low oil shutdown.

1. Fill engine oil to proper level.
Check engine oil before EVERY use.

2. Fuel tank empty or full of impure or low
quality gasoline.

2. Fill fuel tank with fresh 87+ octane stabilizertreated unleaded gasoline.
Do not use gasoline with more than
10% ethanol (E15, E20, E85, etc.).

3. Defective fuel tank cap creating
vacuum, preventing proper fuel flow.

3. Test/replace fuel tank cap.

4. Faulty magneto.

4. Have qualified technician service magneto.

5. Disconnected or improperly
connected spark plug cap.

5. Secure spark plug cap.

1. Dirty air filter.

1. Clean or replace element.

2. Engine running cold.

2. Allow engine to warm up prior
to operating equipment.

1. Old or low quality gasoline.

1. Fill fuel tank with fresh 87+ octane stabilizertreated unleaded gasoline.
Do not use gasoline with more than
10% ethanol (E15, E20, E85, etc.).

2. Engine overloaded.

2. Do not exceed equipment’s load rating.

Operation

3. Incorrect spark timing, deposit buildup,
3. Have qualified technician diagnose
worn engine, or other mechanical problems.
and service engine.

Engine backfires

Product doesn’t
have power

Maintenance

Product begins to
operate abnormally

1. Impure or low quality gasoline.

1. Fill fuel tank with fresh 87+ octane stabilizertreated unleaded gasoline.
Do not use gasoline with more than
10% ethanol (E15, E20, E85, etc.).

2. Engine too cold.

2. Use cold weather fuel and oil
additives to prevent backfiring.

3. Intake valve stuck or overheated engine.

3. Have qualified technician diagnose
and service engine.

4. Incorrect timing.

4. Check engine timing.

1. Product not plugged in properly.

1. Turn off and unplug the product, then
plug it back in again and turn on.

2. Circuit Breaker tripped.

2. Turn off and unplug product, Reset Circuit
Breaker. Plug in product and turn on.

3. Product needs service.

3. Have product repaired.

1. Problem with appliance.

1. Immediately unplug appliance. Have
appliance repaired by a qualified
technician, or replace appliance.

2. Rated load capacity exceeded.

2. Lower the number of items plugged into the
generator to stay within the rated capacity,
or use a more powerful generator.

Follow all safety precautions whenever diagnosing or servicing the equipment or engine.

Page 18

For technical questions, please call 1-888-866-5797.

ITEM 69675

Parts List and Diagram

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM
IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR
MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS
QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE
ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY
STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND
LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY
ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS
THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.

Safety

PLEASE READ THE FOLLOWING CAREFULLY

Parts List

ITEM 69675

Qty
6
1
1
1
1
1
4
1
1
2
1
2
2
2
2
2
2
2
1
2
2
1
1
2
2
1
1
7
1
2
2
1
1
1
1
2
1
1
1
2
1
1
6

Part
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86

Description

Shroud Comp
Bolt,Flange,
Switch Assy,Oil Level
Packing.,Carburetor
Insulator,Carburetor
Packing.,Carburetor
Carburetor
Packing.,Carburetor
Air Cleaner Assy
Element Assy.,Air Cleaner
Nut,Flange
Plate Comp,Side
Bolt,Flange,
Clip,Harness
Coil Assy.,Ignition
Bolt,Flange,
Flywheel Comp
Fan Cooling
Pulley,Starter
Nut,Flange
Recoil Starter Comp.
Starter Assy.
Shaft,Governor Arm
Pin,Lock
Flat Washer
Control Assy.
Spring,Governor
Spring,Throttle Return
Rod,Governor
Arm,Governor
Bolt,Governor Arm
Nut,Flange
Bolt,Flange,
Bolt,Flange,
Block,Muffler
Bracket,Muffler
Gasket,Ex.Pipe
Muffler Assy.
Protector,Muffler
Tank Comp.Fuel
Cap Comp.Fuel Filler
Filter,Fuel
Chamfer Head Screw

For technical questions, please call 1-888-866-5797.

Qty
1
2
1
1
1
1
1
1
1
1
2
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
5
1
1
1
1
1
1
1
1
2

Page 19

Setup

Description

Bolt,Flange,
Cover Comp,Head
Pkg,Head Cover
Tube, Breather
Pkg,Brthr Cover
Cover Comp.,Breather
Bolt,Flange,
Cylinder Head Comp
Spark Plug
Bolt,Stud
Gasket, Cylinder
Pin,Dowel
Bolt,Stud
Rocker Arm Assy.
Valve Rocker Shaft
Rotator,Valve
Retainer,Valve Spring
Spring,Valve
Seal,Valve Stem
Push Rod
Lifter Valve
Valve Assy.
Camshaft Assy.
Flat Washer
Bolt,Drain Plug
Crankcase
Alert Unit,Oil
Bolt,Flange,
Cable Cleat
Oil Seal
Bearing
Governor Kit
Ring Set,Piston
Piston
Pin,Piston
Clip Piston Pin
Conn Rod Assy
Crank Shaft Comp
Packing,Case Cover
Pin,Dowel
Cover Assy.,Crank Case
Cap Assy
Bolt,Flange,

Operation

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43

Maintenance

Part

Parts List (cont.)
Part

Safety
Setup

87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110

Description

Meter Comp.,Fuel
Cock Assy.,Fuel
Bolt,Flange,
Flat Washer
Spring,Cock Lever
Rubber Tank Cushion
Loop,Tube
Tube, Fuel
Alternator Parts
Brush Assy.
Flat Washer
Bolt, Hex.
Housing,Rr
Bolt,Flange,
Bolt,Flange,
Regulator Assy.,Automatic Voltage
Cover,Generator End
Frame Comp.Side
Bolt,Flange,
Frame Comp.
Rubber Tank Cushion
Stay,Air Cleaner
Rubber Column,Bottom
Rubber,Right Bottom

Qty
1
1
4
4
4
4
2
1
1
1
1
1
1
6
4
1
1
1
2
1
1
1
2
2

Part
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134

Description

Nut,Flange
Bolt,Flange,
Rubber,Shock Absorber
Nut,Flange
Plate,Guard
Cable Assy.,Earth
Case, Control Panel
Control Panel Assy.
Socket
Socket
Terminal Set,Earth
Protector,Auto
Protector,Auto
Socket
Switch Assy.,Combination
Panel Output Indicator Light
Rectifier Brige
Carbon Canister Assy
Bracket,Canister
Pipe
Pipe
Pipe Clip
Pipe Clip
Pipe Clip

Qty
8
4
4
4
1
1
1
1
1
2
1
2
1
1
1
1
1
1
1
1
1
1
1
2

Operation
Maintenance

Record Product's Serial Number Here:
Note: If product has no serial number, record month and year of purchase instead.
Note: Some parts are listed and shown for illustration purposes only,
and are not available individually as replacement parts.
Page 20

For technical questions, please call 1-888-866-5797.

ITEM 69675

Maintenance

Operation

Setup

Safety

Assembly Diagram

ITEM 69675

For technical questions, please call 1-888-866-5797.

Page 21

Assembly Diagram (cont.)

Safety
Setup
Operation
Maintenance
Page 22

For technical questions, please call 1-888-866-5797.

ITEM 69675

Warranties

Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and
warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days
from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence
or accidents, repairs or alterations outside our facilities, criminal activity, improper installation, normal wear and tear, or to
lack of maintenance. We shall in no event be liable for death, injuries to persons or property, or for incidental, contingent,
special or consequential damages arising from the use of our product. Some states do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation of exclusion may not apply to you. THIS WARRANTY IS
EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS, EXCEPT FOR THE EMISSIONS CONTROL SYSTEM WARRANTY BELOW.

Safety

Limited 90 Day Warranty (Retail)

To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of
purchase date and an explanation of the complaint must accompany the merchandise. If our inspection verifies the defect, we
will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and
quickly provide you with a replacement. We will return repaired products at our expense, but if we determine there is no defect,
or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product.

Emissions Control System Warranty
The California Air Resources Board and Harbor Freight Tools (HFT) are pleased to explain the emissions control system
warranty on your 2016 Small Off-Road Engine. In California, new equipment that uses small off-road engines must be designed,
built, and equipped to meet the State’s stringent anti-smog standards. HFT must warrant that the emissions control system on
your engine will be free from defects in material and workmanship for two (2) years, provided there has been no abuse, neglect, or
improper maintenance of your engine.

Setup

This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

Your emissions control system may include parts such as the carburetor or fuel-injection system, the ignition system, catalytic
converter, fuel tanks, fuel lines, fuel caps, valves, canisters, vapor hoses, clamps, connectors, and other emissions-related assemblies.
Where a warrantable condition exists, HFT will repair or replace, at our option, your engine if at no cost to you, including
diagnosis, parts and labor.

MANUFACTURER’S WARRANTY COVERAGE

OWNER’S WARRANTY RESPONSIBILITIES
As the engine owner, you are responsible for the performance of the required maintenance listed in your Owner’s Manual.
As the engine owner, you should however be aware that HFT may deny you warranty coverage if your engine or a part has
failed due to abuse (including failure to follow the fuel use instructions contained in this manual), neglect, improper maintenance,
or unapproved modifications.

Maintenance

You are responsible for contacting HFT as soon as the problem exists in order to obtain warranty repair or replacement, by
doing either of the following: (a) contact HFT product support at 1-888-866-5797 or productsupport@harborfreight.com; or (b) bring
the to your nearest Harbor Freight Tools retail store. The nearest Harbor Freight Tools retail store can be found on the internet at
http://www.harborfreight.com. The warranty repairs or replacement should be completed in a reasonable amount of time, not to
exceed 30 days. If you have a question regarding your warranty coverage, you should contact HFT product support at 1-888-866-5797
or productsupport@harborfreight.com.

Operation

This emissions control system is warranted for two years. If any emission-related part on your engine is defective, the part will
be repaired or replaced by HFT.

ITEM 69675

For technical questions, please call 1-888-866-5797.

Page 23

GENERAL EMISSIONS WARRANTY COVERAGE
a) The warranty period begins on the date the engine or equipment is delivered to an ultimate purchaser. The warranty period is two
years.
b) HFT warrants to the initial owner and each subsequent owner that the engine is:
1.

Designed, built, and equipped so as to conform with all applicable regulations adopted by the Air Resources Board; and

2.

Free from defects in materials and workmanship that causes the failure of a warranted part for a period of two years.

c) The warranty on emissions-related parts is as follows:
1.

Any warranted part that is not scheduled for replacement as required maintenance in the written instructions provided, is
warranted for the warranty period stated above. If any such part fails during the period of warranty coverage, it will be repaired
or replaced HFT. Any such part repaired or replaced under the warranty will be warranted for the remaining warranty period.

2.

Any warranted part that is scheduled only for regular inspection in the written instructions is warranted for the warranty period
stated above. A statement in the written instructions to the effect of “repair or replace as necessary” does not reduce the period
of warranty coverage. Any such part repaired or replaced under warranty will be warranted for the remaining warranty period.

3.

Any warranted part that is scheduled for replacement as required maintenance in the written instructions will be warranted
for the period of time prior to the first scheduled replacement point for that part. If the part fails prior to the first scheduled
replacement, the part will be repaired or replaced by HFT. Any such part repaired or replaced under warranty will be warranted
for the remainder of the period prior to the first scheduled replacement point for the part.

4.

Repair or replacement of any warranted part under the warranty will be performed at no charge to the owner at a retail store
or by HFT paying for shipping the product for repair.

5.

Notwithstanding the provisions herein, warranty services or repairs will be provided at all retail stores or by contacting HFT
product support at 1-888-866-5797 or productsupport@harborfreight.com.

6.

The owner will not be charged for diagnostic labor that leads to the determination that a warranted part is in fact defective,
provided that such diagnostic work is performed at a retail store.

7.

HFT is liable for damages to other engine components proximately caused by a failure under warranty of any warranted part.

8.

Throughout the emissions warranty period stated above, HFT will maintain a supply of warranted parts sufficient to meet the
expected demand for such parts.

9.

Any replacement part may be used in the performance of any warranty maintenance or repairs and will be provided without
charge to the owner. Such use will not reduce the warranty obligations of HFT.

10. Add-on or modified parts that are not approved by HFT may not be used. The use of any non‑exempted add-on or modified
parts will be grounds for disallowing a warranty claim. HFT is not liable to warrant failures of warranted parts caused by the
use of a non-exempted add-on or modified part.
d) Emission Warranty Parts List.
1. Fuel Metering System
a. Carburetor and its internal parts (and/or pressure regulator
or fuel injection system).
b. Fuel tank.
c. Cold start enrichment system.
d. Air/fuel ratio feedback and control system.
2. Air Induction System
a. Controlled hot air intake system.
b. Intake manifold.
c. Air filter.
3. Ignition System
a. Spark plugs.
b. Magneto ignition system.
c. Spark advance/retard system.

4. Catalyst System (if so equipped)
a. Exhaust pipe stud/exhaust manifold.
b. Thermal reactor.
c. Catalytic converter (if so equipped).
5. Particulate Controls
a. Traps, filters, precipitators, and any other device used to
capture particulate emissions.
6. Miscellaneous Items Used in Above Systems
a. Vacuum, temperature and time sensitive valves and
switches.
b. Hoses, belts, connectors, and assemblies.
7. Evaporative Emission Control System
a. Fuel tank.
b. Fuel caps, valves, canisters, filters, vapor hoses, clamps,
connectors, belts, and assemblies.

HFT provides with each product written instructions for the maintenance and use of the product by the owner.

3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 93011 • 1-888-866-5797



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c123 79.158978, 2016/02/13-01:11:19
Instance ID                     : uuid:ba41ad3b-deb3-964e-9a38-dab0b9b43864
Original Document ID            : adobe:docid:indd:7433f15f-7ee1-11df-9488-aa083f618b49
Document ID                     : xmp.id:e3fdd034-9cca-45e1-8a0b-1f298c83c775
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:ef4c5b33-6e86-47be-b2b6-cae9cfdd336c
Derived From Document ID        : xmp.did:ef4c5b33-6e86-47be-b2b6-cae9cfdd336c
Derived From Original Document ID: adobe:docid:indd:7433f15f-7ee1-11df-9488-aa083f618b49
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Macintosh)
History Changed                 : /
History When                    : 2016:07:19 13:06:59-07:00
Create Date                     : 2016:07:19 13:06:59-07:00
Modify Date                     : 2016:07:19 13:07:11-07:00
Metadata Date                   : 2016:07:19 13:07:11-07:00
Creator Tool                    : Adobe InDesign CC 2015 (Macintosh)
Export Script                   : Export pdf script v3.82
Format                          : application/pdf
Creator                         : Adobe
Rights                          : Copyright© 116 by Harbor Freight Tools®.  All rights reserved.  No portion of this document or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools.
Marked                          : True
Web Statement                   : http://www.harborfreight.com
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 24
Author                          : Adobe
EXIF Metadata provided by EXIF.tools

Navigation menu