Operating Manual For 500A/102A/152A/202A Power Supply Pmn 83493001
User Manual: pmn
Open the PDF directly: View PDF .
Page Count: 60
Download | |
Open PDF In Browser | View PDF |
INSTRUCTION MANUAL FOR 500A/102A/152A/202A POWER SUPPLY Document: 83493001 Rev. P TDK-Lambda Americas 405 Essex Road, Neptune, NJ 07753 Tel: (732) 922-9300 Fax: (732) 922-9334 Web: www.US.TDK-Lambda.com/HP TDK-Lambda MANUFACTURER'S PRODUCT DECLARATION INTENDED PURPOSE (USE) The Power Supplies described by this manual are defined by TDK-Lambda Americas Inc. as a component for use in the composition of an apparatus as defined in Article 1 (1) of the EMC Directive (89/336/EEC). These products, as individual components, do not perform in themselves a direct function for the user of the end product. They are not intended to be placed on the market with a direct function to a final user! As such, the products described by this manual are not subject to the provisions of the EMC Directive (89/336/EEC, with amendment 92/31/EEC). The products described by this manual are intended for incorporation into a final product by a professional assembler. It is the responsibility of the assembler to ensure that the final apparatus or system incorporating our products complies with all relevant EMC standards for that final product. OPERATING ENVIRONMENT The operating environment as defined by TDK-Lambda Americas Inc., for the products described by this manual is stated as follows: The Power Supplies described by this manual are intended for use in a protected industrial environment or in proximity to industrial power installations. These locations are often referred to as industrial locations containing establishments that are not connected to the low voltage public mains network. Industrial locations are characterized by the existence of one or more of the following conditions: 1) industrial, scientific and medical (ISM) apparatus are present; 2) heavy inductive or capacitive loads are frequently switched; 3) currents and associated magnetic fields are high; 4) location supplied by their own transformer. These components are not intended for connection to a public mains network, but are intended to be connected to a power network supplied from a high or medium-voltage transformer dedicated for the supply of an installation feeding manufacturing or similar operations. They are suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Page: 83-000-006 Rev D TDK-Lambda Description of symbols used in product labeling SYMBOL PUBLICATION DESCRIPTION EC Council European Community Directive 93/68/EEC Conformity Assessment Product Mark IEC 348 Attention, consult Accompanying documents IEC 60417-1-5036 Dangerous voltage IEC 60417-1-5019 Protective earth (e.g. power line earth ground) IEC 60417-1-5017 Functional earth (e.g. chassis ground) IEC 60417-1-5134 Electrostatic Discharge (ESD) Sensitive Device Page: 83-000-007 Rev E ELECTRICAL STANDARDS All company primary standards are either certified or are traceable to certification by the National Institute of Standards and Technology. CLAIM FOR DAMAGE IN SHIPMENT This instrument received comprehensive mechanical and electrical inspection before shipment. Immediately upon receipt from the carrier, and before operation, this instrument should be inspected visually for damage caused in shipment. If such inspection reveals damage in any way, a claim should be filed with the carrier. A full report of damage should be obtained by the claim agent and this report should be forwarded to us. We will then provide a disposition of the equipment and arrange for repair or replacement. When referring to this equipment, always include the model and serial numbers. The “WARRANTY”, “CLAIM FOR DAMAGE IN SHIPMENT”, and “RETURNING EQUIPMENT” information applies to equipment purchased directly from TDKLambda Americas Inc. End users receiving equipment from a third party should consult the appropriate service organization for assistance with these issues. RETURNING EQUIPMENT Before returning any equipment to the factory, the following steps shall be taken. 1. Notify TDK-Lambda Americas Inc. at 732-918-6888 or follow the instructions at www.US.TDK-Lambda.com/HP/service.htm. Give a full description of the difficulty including the model and serial number of the unit in question. Upon receipt of this information, we will assign a Return Material Authorization (RMA) number and provide shipping instructions. 2. The customer shall prepay shipping charges. Equipment returned to us must be packed in a manner to reach us without damage. The shipping container must be marked with the RMA number in an area approximate to the shipping label with numbers that are easy to read. All returned units that do not show the RMA number on the outside of the container will be refused. If the equipment is repaired within the warranty agreement, than TDK-Lambda Americas Inc. shall pay for the return shipping to the customer. 3. For non-warranty repairs, we will submit a cost estimate for your approval prior to proceeding. The customer shall pay return shipping charges. MECHANICAL INSTALLATION Most power supplies are heavy and, when rack mounted, they should be supported by rails along the sides of the supply from front to rear. The rails must adequately support the unit and not block airflow. Do not support the power supply from the front panel only. Page: 83-000-011 Rev K TABLE OF CONTENTS CHAPTER 1 INTRODUCTION ........................................................................................................................ 1 1.1 DESCRIPTION ....................................................................................................................................... 1 CHAPTER 2 SPECIFICATIONS ..................................................................................................................... 2 2.1 AVERAGE CHARGING RATE ............................................................................................................... 2 2.2 PEAK CHARGING RATE ....................................................................................................................... 2 2.3 NUMBER OF MODELS IN SERIES ....................................................................................................... 2 2.4 STANDARD VOLTAGE RANGES .......................................................................................................... 2 2.4.1 LINEARITY ...................................................................................................................................... 2 2.4.2 ACCURACY .................................................................................................................................... 2 2.5 POLARITY .............................................................................................................................................. 2 2.6 HIGH VOLTAGE ASSEMBLY ................................................................................................................ 2 2.7 INPUT CONNECTOR............................................................................................................................. 2 2.8 INPUT CHART ....................................................................................................................................... 2 2.9 POWER FACTOR .................................................................................................................................. 3 2.10 EFFICIENCY ........................................................................................................................................ 3 2.11 STORED ENERGY .............................................................................................................................. 3 2.12 STABILITY ........................................................................................................................................... 3 2.13 PULSE TO PULSE REPEATABILITY .................................................................................................. 3 2.14 TEMPERATURE COEFFICIENT ......................................................................................................... 3 2.15 AMBIENT TEMPERATURE ................................................................................................................. 3 2.16 HUMIDITY ............................................................................................................................................ 3 2.17 PROTECTION ...................................................................................................................................... 3 2.18 AGENCY APPROVALS ....................................................................................................................... 3 2.19 TRANSIENT LINE PROTECTION........................................................................................................ 3 2.20 ESD ...................................................................................................................................................... 3 2.21 NOTE FOR PFC UNITS ....................................................................................................................... 3 2.22 ACCESSORIES ................................................................................................................................... 4 2.23 OPTIONS ............................................................................................................................................. 4 2.23.1 Suffix –LH ...................................................................................................................................... 4 2.23.2 SUFFIX –EN ................................................................................................................................. 4 2.23.3 Suffix -5V ....................................................................................................................................... 4 2.23.4 Suffix –LP ...................................................................................................................................... 4 2.23.5 SUFFIX -110 ................................................................................................................................. 4 2.24 ORIENTATION ..................................................................................................................................... 4 CHAPTER 3 INSTALLATION ......................................................................................................................... 9 3.1 INITIAL INSPECTION ............................................................................................................................ 9 3.2 MOUNTING AND COOLING REQUIREMENTS .................................................................................... 9 3.3 INPUT AC POWER ................................................................................................................................ 9 3.4 POWER CORD SPECIFICATION: .......................................................................................................10 3.5 CONNECTING HIGH VOLTAGE OUTPUT ..........................................................................................11 3.6 GROUNDING THE PRODUCT ............................................................................................................12 3.6.1 GROUNDING OF INPUT LINE .....................................................................................................12 3.6.2 OUTPUT GROUND CONNECTION .............................................................................................12 3.6.3 FOR UNITS WITH O/P VOLTAGE ≤ 6kV .....................................................................................12 3.6.4 FOR UNITS WITH O/P VOLTAGE > 6kV: ....................................................................................12 CHAPTER 4 OPERATION ............................................................................................................................13 4.1 REMOTE CONTROL............................................................................................................................13 4.2 OUT-OF-BOX-INSPECTION ...............................................................................................................15 4.2.1 VISUAL INSPECTION ..................................................................................................................15 83-493-001 4Rev. P 4.2.2 ELECTRICAL INSPECTION .........................................................................................................15 4.3 CONTACTING TDK-LAMBDA AMERICAS CUSTOMER SERVICE ...................................................16 CHAPTER 5 APPLICATIONS .......................................................................................................................17 5.1 DETERMINING CAPACITOR CHARGE TIME.....................................................................................17 5.2 VOLTAGE REVERSAL ........................................................................................................................17 5.3 PARALLELING UNITS .........................................................................................................................18 5.4 MEASURING HIGH VOLTAGES .........................................................................................................19 5.5 DETERMINING AC LINE CURRENT ...................................................................................................20 5.6 CONTINUOUS HV DC OPERATION (CONSTANT VOLTAGE) ..........................................................20 5.7 LONG CHARGE TIME WITH POWER FACTOR CORRECTED (PFC) UNITS ...................................21 CHAPTER 6 MAINTENANCE AND CALIBRATION ....................................................................................22 6.1 SAFETY PRECAUTIONS.....................................................................................................................22 6.2 MAINTENANCE ...................................................................................................................................22 6.3 CALIBRATION .....................................................................................................................................22 LIST OF FIGURES Figure 1-1 500A/102A/152A/202A Block Diagram ......................................................................... 1 Figure 2-1 Mechanical Dimensions for 500A, 102A, 152A Outputs up to 6KV ............................... 5 Figure 2-2 Mechanical Dimensions for 500A, 102A, 152A Outputs from 7KV to 40KV .................. 6 Figure 2-3 Mechanical Dimensions for 202A Outputs up to 6KV ................................................... 7 Figure 2-4 Mechanical Dimensions for 202A Outputs from 7KV to 40KV ...................................... 8 Figure 3-1 Input AC Power Connection NON-PFC Version ......................................................... 10 Figure 3-2 Input AC Power Connection, PFC Version ................................................................. 10 Figure 3-3 Output Ground Connection ........................................................................................ 12 Figure 4-1 Example of Interface Connection ............................................................................... 14 Figure 5-1 Output Voltage Waveform ......................................................................................... 17 Figure 5-2 Output Current Measurement.................................................................................... 17 Figure 5-3 HV Bias Measurements ............................................................................................. 20 TABLES Table 2-1: High Voltage Cable ...................................................................................................... 2 Table 2-2: Input Voltage Chart ...................................................................................................... 2 Table 2-3 Power Factor................................................................................................................ 3 Table 4-1 Control Interface Connection for Standard 500A/102A/152A/202A Series .................. 13 Table 5-1 Output Capacitance ................................................................................................... 18 83-493-001 5Rev. P CHAPTER 1 INTRODUCTION 1.1 DESCRIPTION The Series 500A/102A/152A/202A are High Voltage Switching Power Supplies designed specifically for charging capacitors in laser systems and other pulsed power applications. The 500A provides 500 J/s. the 102A is 1000 J/s, 152A is 1,500 J/s, and the 202A provides 2000 J/s of average power and can be paralleled indefinitely for higher total system power. TDK-Lambda Americas Inc. also offers the 402 Series, 802 Series, and 303 Series rated at 4,000, 8,000 and 30,000 J/s respectively. The 500A/102A/152A/202A power supplies incorporate a new high-frequency IGBT parallel resonant inverter topology for efficient generation of the output power. A highperformance control module precisely regulates the output voltage, automatically compensating for line, load, temperature, and rep rate variations. Normal external fault conditions such as line dropout open or short circuit load, HV arc and over-temperature will not damage the unit. The latest development in the parallel resonant inverter topology and control circuitry also drastically improves pulse-to-pulse repeatability by reducing the ripple or “bucket effect” even at very high pulse repetition frequencies. The output voltages of the 500A/102A/152A/202A supplies are fully adjustable over each range. INPUT/POWER High Freq. Resonant Inverter PFC / Fuses Inrush Limit Step-up Transformer HV Rect. HV Filter Control & Aux. Power Figure 1-1 500A/102A/152A/202A Block Diagram 1 83-493-001 Rev. P HV OUTPUT CHAPTER 2 SPECIFICATIONS 2.1 AVERAGE CHARGING RATE 500J/s, 1000J/s, 1500J/s, 2000J/s at rated Output Voltage 2.2 PEAK CHARGING RATE 550J/s, 1100J/s, 1650J/s, 2200J/s at rated Output Voltage 2.3 NUMBER OF MODELS IN SERIES 12 Standard (others at extra cost) 2.4 STANDARD VOLTAGE RANGES 1kV, 1.5kV, 2kV, 3kV, 4kV, 5kV, 5kV, 10kV, 15kV, 20kV, 30kV and 40kV. All models continuously variable from 0 to 100% of rated output voltage. 2.4.1 LINEARITY Linear to within 1% of full scale. 2.4.2 ACCURACY 1% of rated. 2.5 POLARITY Available as fixed Positive or Negative 2.6 HIGH VOLTAGE ASSEMBLY Insulating Medium/Cable Voltage Medium Output Cable 1kV to 6kV Air Coax. RG59 10kV to 40kV Oil 12 AWG, HV Silicon Table 2-1: High Voltage Cable 2.7 INPUT CONNECTOR VDE, UL approved. 2.8 INPUT CHART Input Voltage selective by Terminal block position Input Voltage (VAC) Current (No PFC) Current (PFC) Nameplate Design 500A 102A 152A 500A 102A 152A 202A Range Range 230 180-253 5A 10A 14.5A 3.5A 6.6A 10A 13.5 50/60Hz 50/60Hz 115 90-140 10A 20A N/A 7A N/A N/A N/A 50/60Hz 50/60Hz *Note: Input current ratings given are maximum when output Repetition Rate is =>10Hz Consult Factory if model used at less than 10Hz. Table 2-2: Input Voltage Chart 2 83-493-001 Rev. P 2.9 POWER FACTOR Non PFC PFC All models 0.65 0.98 Table 2-3 Power Factor 2.10 EFFICIENCY Better than 85% 2.11 STORED ENERGY Less than 0.3 Joules all models 2.12 STABILITY 0.2% per hour after 1 hour warm up 2.13 PULSE TO PULSE REPEATABILITY ±0.2% to 300Hz. For higher repetition rates, consult factory 2.14 TEMPERATURE COEFFICIENT 100ppm per ºC 2.15 AMBIENT TEMPERATURE Storage -40 to +85ºC. Operating -20 to +45ºC 2.16 HUMIDITY 90%, non-condensing 2.17 PROTECTION The power supply is protected against Open Circuits, Short Circuits, Overloads and Arcs 2.18 AGENCY APPROVALS The 500A, 102A, 152A power supplies are safety approved by UL to UL 60601-1: 1990+A1+A2: 1995. All of the standard supplies with output voltages between 1kV and 40kV with or without active PFC are certified UL to meet the safety requirements of UL60601-1 with the following exceptions. 1. Conducted RFI to be assessed in the installed application. 2. IEC601-1 approved isolation transformer is required to meet leakage current. 2.19 TRANSIENT LINE PROTECTION Meets requirements of IEC 801-4, 801-5 2.20 ESD All Remote Control Functions meet requirements of IEC 801-2 2.21 NOTE FOR PFC UNITS When High Voltage is enabled by using either the “HV Enable” Line or deactivation of the “Inhibit” Line the power supply will reach normal operation mode (and therefore all other published specifications) within 50ms. 3 83-493-001 Rev. P 2.22 ACCESSORIES • • • Detachable 8 foot (2.4 meter) HV Cable 15 pin “D” plug mating control connector Operating Manual 2.23 OPTIONS 2.23.1 Suffix –LH “Low Inhibit” - A +10 to 15 volt (high) signal will allow power supply operation. A 0 to +1.5 volt (low) signal will inhibit the supply. 2.23.2 SUFFIX –EN “Low Enable” - A +10 to 15 volt (high) signal will disable power supply operation. A 0 to +1.5 volt (low) signal will enable the supply. 2.23.3 Suffix -5V 0 to +5 volt voltage (0 to full-scale output) programming. For controlling the unit VPROGRAM is 0-5V (remote pin 5). The value for VPEAK is 0-5.5V (remote pin 7) and the value for VANALOG is 0-5.5V (remote pin 8). 2.23.4 Suffix –LP Latching overload protection. 2.23.5 SUFFIX -110 100 to 120 VAC input option (availability limited). 2.24 ORIENTATION Power supplies >6kV with a oil-filled H.V. section must be operated in an upright position. i.e., with the mounting bracket parallel to the ground plane. 4 83-493-001 Rev. P Figure 2-1 Mechanical Dimensions for 500A, 102A, 152A Outputs up to 6kV (for grounding instructions see SECTION 3.6) 5 83-493-001 Rev. P Figure 2-2 Mechanical Dimensions for 500A, 102A, 152A Outputs from 7kV to 40kV (for grounding instructions see SECTION 3.6) 6 83-493-001 Rev. P Figure 2-3 Mechanical Dimensions for 202A Outputs up to 6kV (for grounding instructions see SECTION 3.6) 7 83-493-001 Rev. P Figure 2-4 Mechanical Dimensions for 202A Outputs from 7kV to 40kV (for grounding instruction see SECTION 3.6) 8 83-493-001 Rev. P CHAPTER 3 INSTALLATION 3.1 INITIAL INSPECTION The shipping container contains the following items: power supply, HV output cable, male 15-pin “D” remote control mating connector, mounting bracket and operator’s manual. Examine the items immediately for damage. Locate the serial number label on the end of the power supply and verify the model number, the input voltage rating and the output voltage rating and polarity. In the event of any damage promptly notify the transportation company and the TDK-Lambda Americas Inc. Customer Service Department. 3.2 MOUNTING AND COOLING REQUIREMENTS The power supply can be mounted by the chassis support brackets (see Figure 2-1, 2-2, 2-3 and 2-4 for details). The mounting brackets are attached to the supply using the four PHMS 8-32NC X 0.250 screws included. Using longer screws may internal components to ground, causing permanent damage to power supply. The power supply can also operate on a bench or table top. Power supplies above 6kV with an oil-filled H.V. section must be operated in an upright position i.e. mounting bracket parallel to ground plane. In all cases adequate clearances must be provided for proper air flow and cable bends. Keep the minimum HV cable bend radius greater than 4 inches (102mm) to minimize stress on the insulation and at least 4 inches (102mm) of clearance at the inlet of the power supply and 2 inches (51mm) at the sides. When operating in an enclosed system, care must be taken to ensure the ambient inlet air to the power supply does not exceed the maximum operating temperature of 45ºC. 3.3 INPUT AC POWER Proper grounding from the input AC power is required to reduce the risk of electric shock. The metal chassis of the power supply is grounded through the green earthing wire at the input AC power terminal block. A protective ground connection by way of the grounding conductor in the input terminal is essential for safe operation. Use extreme caution when connecting input AC power and never apply the incorrect input power. The PFC version and version without PFC should be connected as explained in the following 2 paragraphs. A. Version with no PFC. For this version, the supply may be connected to either 115VAC for 230VAC input voltage (See table 2.2 for availability). These connections are shown in Figure 3-1. For 115VAC connect the input line wires to L1 and COM terminals. For 230VAC connect the input wires to L2 and COM terminals. B. Version with PFC. The PFC version connection is shown in Figure 3-2. Connect the input voltage line wires to L2 and COM terminals. 9 83-493-001 Rev. P Figure 3-1 Input AC Power Connection NON-PFC Version Figure 3-2 Input AC Power Connection, PFC Version The 500A, 102A, 152A power supplies are safety approved by UL to UL60601-1. An IEC601-1 approved isolation transformer is required to meet leakage current. 3.4 POWER CORD SPECIFICATION: Use wire with minimum .064 inches (1.6mm) diameter and 600 V insulation. 10 83-493-001 Rev. P 3.5 CONNECTING HIGH VOLTAGE OUTPUT POTENTIAL LETHAL VOLTAGE Ensure that the power supply is off and disconnected from the input power and never operate the power supply without a load capacitor. Make sure that all load capacitors are discharged and shorted to ground before making any connections. TDK-Lambda Americas Inc. recommends the use of safety dump switches in high voltage discharge circuits. Never handle the HV cable during operation. This power supply is designed to operate with a capacitive load. Operation of the power supply without an external load capacitor may result in damage to internal circuitry. Always use the HV connector and cable provided with the power supply or an equivalent substitute provided by TDK-Lambda Americas Inc. Fully insert the connector end of the HV cable and tighten the locking nut only “hand tight”. NOTE: When operating above 20kV and/or 200 Hz rep. rate, ensure that silicone grease (such as Dow Corning DC-4) is applied to the HV cable before insertion into the HV connector. This displaces the air in the connector and reduces long term corona damage. Keep the HV cable bend radius greater than 4 inches (102mm) to minimize stress on the insulation. Keep the HV cable as distant as possible from the input power and the input control signals. Some peak current will flow out of the power supply during discharge and return through the HV return and system chassis. This current comes from voltage reversal in under damped systems and from normal discharge of filter and cable capacitance. The path for this current should not parallel control signal returns since the resulting voltages could interfere with normal system operation. The currents developed with voltage reversal at high rep. rates, could damage the power supply. A resistor in series with the HV output can be added to limit this current to an acceptable level. Refer to Section 5.2, Page 16 or the TDK-Lambda High Power online application notes for more information. The oil-filled HV assembly should not be opened. The oil and components have been specially cleaned and vacuum impregnated at the factory and the assembly hermetically sealed. Opening the assembly will compromise performance and void the warranty. Tanks must only be serviced at TDK-Lambda Americas Inc. 11 83-493-001 Rev. P 3.6 GROUNDING THE PRODUCT 3.6.1 GROUNDING OF INPUT LINE The supply is grounded through the ground terminal of the input connector. A protective ground connection by the way of the grounding conductor in the input terminal is essential for safe operation. 3.6.2 OUTPUT GROUND CONNECTION It is important that there be a ground connecting the supply to the load as shown in Figure 3-3. Figure 3-3 Output Ground Connection 3.6.3 FOR UNITS WITH O/P VOLTAGE ≤ 6kV The ground connection is made via the shield of the RG59 coaxial HV output cable provided with the supply. 3.6.4 FOR UNITS WITH O/P VOLTAGE > 6kV: The ground connection between the load and the supply must be made with a separate wire to the 8-32 UNC, ½ “long grounding stud provided on the supply. 12 83-493-001 Rev. P CHAPTER 4 OPERATION 4.1 REMOTE CONTROL The Series 500A/102A/152A/202A is easily controlled through the remote connector on the input panel of the unit. Only the ENABLE/RESET, V PROGRAM and GND signals are required for operation. The remaining signals are provided for status monitoring and fault diagnosis. A schematic diagram showing the suggested interface circuit is shown in Figure 4-1. This table is for a standard configuration. PIN SIGNAL NAME I/O DESCRIPTION 1 ENABLE/RESET INPUT A high signal (+10 to 15V) with respect to ground (pin 14) will enable the power supply. Latching faults can be cleared by cycling this switch. Ground or open disables the supply. 5 VPROGRAM INPUT A 0-10V signal with respect to ground at this pin programs the output voltage proportionally from zero to rated output. For a “-5V” option the unit VPROGRAM is 0-5V. 7 VPEAK OUTPUT A 0-10V signal with respect to ground proportional to the peak of the output charging voltage. Can be used to drive a meter displaying peak output voltage. For a “-5V” option the value for VPEAK is 0-5.5V. 8 VANALOG OUTPUT 0-10V analog of output charging voltage waveform. For a “-5V” option the value for VANALOG is 0-5.5V (remote pin 8). 10 INHIBIT INPUT A +10 TO 15V with respect to ground, disables the unit. Open or ground allows operation. This input can be used to disable charging during HV switch recovery. 9, 11 +15V OUTPUT 15V regulated. Can be used or programming applications 20mA max. 14 GND OUTPUT Control circuit return. Also chassis/earth ground 15 INHIBIT LED OUTPUT INHIBIT LED displays the logical OR of all the internal and external signals that prevent HV output current, including EOC, EXTERNAL INHIBIT, OVERLOAD, and any fault. 13 EOC LED OUTPUT Open collector. Indicates that the power supply is reaching end-of-charge, i.e. the V PROGRAM set point. 3, 6 SUMMARY FAULT LED OUTPUT Open collector. Indicates an output overvoltage. Temperature fault or low input voltage condition. 2 LOAD FAULT OUTPUT Indicates a shorted O/P or a very large load capacitor. user Table 4-1 Control Interface Connection for Standard 500A/102A/152A/202A Series 13 83-493-001 Rev. P Figure 4-1 Example of Interface Connection 14 83-493-001 Rev. P 4.2 OUT-OF-BOX-INSPECTION LETHAL VOLTAGES PRESENT 4.2.1 VISUAL INSPECTION Prior to shipment, this instrument was inspected and found to be free of mechanical and electrical defects. As soon as the unit is unpacked, inspect for any damage that may have occurred in transit. Verify the following: A. Confirm that there are no dents or scratches on the panel surfaces. If any damage is found, follow the instructions in the "Returning Equipment" instructions section of this manual. 4.2.2 ELECTRICAL INSPECTION Before the power supply is installed in a system, verify that no internal damage occurred during shipping. A simple preliminary electrical test should be performed. This test is described below. 4.2.2.1 TEST 1 Purpose: Verify general overload operation. 1. With AC power "OFF" and disconnected, short the H.V. output by connecting the center conductor of the output cable to its return shield (or ground). This dead short forces the unit to generate full output current at zero voltage. 2. Set the output voltage control to zero. Connect the AC power to the unit. Turn the AC power "ON". 3. Turn the he H.V. on and turn up the H.V. control until the power supply is generating output current into the dead short. The power supply will intermittently turn on and off indicating the "overload" condition. The unit should continue to cycle in this mode with a 1 sec. repetition rate indefinitely (500mS on and 500mS off). The power supply will go into overload when max. current is drawn for more than half a second. 4. Turn off the H.V. and A.C. power. This test indicates the inverter section is generating maximum current and the logic and overload circuitry works correctly. 4.2.2.2 TEST 2 Purpose: Verify that the power supply generates maximum rated voltage, and the regulation and feedback circuits are functioning. 1. With AC power OFF and disconnected, connect an appropriate load capacitor to the power supply output cable. 2. Prepare to charge the capacitor. NOTE: Operating a 502A/102A/152A/202A power supply into an open circuit (no load operation) will instantly damage the power supply's H.V. output diodes. Make sure the load (capacitor) is connected and the H.V. output cable is securely inserted and connected. 3. Turn the voltage control all the way down to zero, apply AC power and turn the HV ON. By turning up the H.V. control knob the capacitor will charge to the programmed voltage The power supply may be turned all the way up to its maximum output voltage provided the load capacitor is sufficiently rated. 15 83-493-001 Rev. P 4. By turning the voltage control down or turning the H.V. OFF, the capacitor will "bleed" down through the internal voltage divider resistors used for regulation feedback. NOTE: An overload condition can occur if the INHIBIT signal is missing, allowing HV switch to latch-up. It can also occur if the discharge rep. rate is too high to allow the capacitor to fully charge to V PROGRAM. Test #2 indicates the H.V. section is working correctly. Tests 1 and 2 generally indicate the unit is functioning as designed. Although 100% power had not been generated, these two tests give greater than 90% confidence that the unit is not damaged. If any inconsistency from the above test procedure is noted, do not hesitate to call Lambda Americas Customer Service for assistance. If equipped with an oil-filled tank this assembly should not be opened unless. This oil filled tank has been hermetically sealed at the factory. Opening the supply or the assembly will void the factory warranty, and may compromise performance. 4.3 CONTACTING TDK-LAMBDA AMERICAS CUSTOMER SERVICE When contacting customer service locate the product description, part number and serial number from the label located on the rear of the unit, and have this information available. Phone: (732) 922-9300 x 342 E-mail: hp.service@us.tdk-lambda.com Fax: (732) 922-5403 Customer Service, or an approved Service Center, should be contacted if: • The power supply is mechanically or electrically damaged. • The power supply requires on-site calibration, or replacement warning decals. • The customer has questions about a special application that is not described in this manual. Normally, the customer may NOT open any chassis covers that have a warranty seal. Breaking a seal will void the warranty. At the discretion of TDK-Lambda Americas, the customer may be granted permission to break the warranty seal and open the chassis covers. Customer Service shall confirm the permission by sending a replacement seal. Once the unit has been serviced, the customer shall close the cover and apply the replacement seal adjacent to (not on top of) the broken seal. 16 83-493-001 Rev. P CHAPTER 5 APPLICATIONS For clarification and further technical assistance specific to your applications, please contact TDK-Lambda Americas Inc. 5.1 DETERMINING CAPACITOR CHARGE TIME The ratings of these supplies are as follows: 500A – 500 J/s, 102A – 1000 J/s, 152A – 1500J/s, 202A-2000J/s average charge rate. Although the measure of Joules/sec equates to Watts, Stored Energy per unit time is more convenient when working with energy storage capacitors. The peak charge rate determines the capacitor charge time. The average charge rate determines the total power delivered from the power supply. It is possible to charge a capacitor at 1650 J/sec, but to discharge it at a low rep. rate producing an average of 100 J/sec. The following formulas can be used to determine the average and peak charge rate. V O L TA G E Tc Peak Charge Rate = Tp 1 2 2 CV Average Charge Rate = Average Charge Rate = C - OUTPUT LOAD CAPACITOR TC 1 2 2 CV Tp TI M E V - PROGRAMMED OUTPUT VOLTAGE AND SHOWN IN FIGURE P ARE TTCC and TPTare shown in figure Figure 5-1 Output Voltage Waveform 5.2 VOLTAGE REVERSAL When the capacitor or PFN is discharged, a high peak current may flow out of the power supply as a result of voltage reversal. This occurs in a system which is under damped in order to clear the high voltage switch after each pulse. The average value of this peak current added to the normal output current may exceed the rating of the HV diodes in the power supply. This current can be measured with a current transformer as shown in Figure 5.2. Figure 5-2 Output Current Measurement 17 83-493-001 Rev. P A series terminating resistor (or series inductor or clamp diode) must be added as shown if the average value of the peak current exceeds 110% of the normal output current. When choosing Rs, ensure it can withstand the full output voltage across it as well as the power dissipation caused by discharging Co (see Table 5.1) and Cc (20pF/ft) (65.62 pf/m) each cycle as well as conducting the normal output current. It’s power dissipation can be calculated as Pd = (Io² Rs) + ½ (Co + Cc) V² (REP RATE). Output Voltage Co 1-2.8kV 60nF 3kV-6kV 15nF 10-30kV 460pF 40kV 230pF Table 5-1 Output Capacitance 5.3 PARALLELING UNITS The 500A/102A/152A/202A power supplies are designed for simple parallel operation. The input power and HV output should be connected directly together. The REMOTE connectors on the input panel can also be connected directly together using a “daisy chain” ribbon cable from the system controller. Each of the power supplies operate at the same time with the total charge rate equal to the sum of each. Sometimes when operating several units in parallel, the high total power generates noise which interferes with the power supply control. This is usually due to the many interconnecting control cables acting as an antenna picking up noise. The problem usually appears as one or more of the power supplies shuts down when the output voltage increases beyond a certain level. Dressing the control cables as short as possible and close to ground or using shielded cables should help. In severe cases, it is necessary to wrap the cables several times through high permeability ferrite cores at the input panel of each unit. The 500A/102A/152A/202A power supplies can also be used as an Isolated High Voltage continuous DC power source by adding an external filter capacitor. The value of the filter capacitor depends upon the value of the allowable output voltage ripple value. For parallel operation into DC loads, please contact TDK-Lambda Americas Inc. Customer Service Department. (See Section 5.6). 18 83-493-001 Rev. P 5.4 MEASURING HIGH VOLTAGES WARNING: EXTREME CAUTION MUST ALWAYS BE EXERCISED WHEN TAKING ANY HIGH VOLTAGE MEASUREMENTS. IT SHOULD BE DONE ONLY BY QUALIFIED PERSONNEL WHO ARE TRAINED IN THE SAFETY ASPECTS OF WORKING WITH HIGH VOLTAGE. A sample of the output voltage is available at the REMOTE connector. If it is desired to measure the HV output externally, care must be taken to understand the accuracy of the measurement. When making a DC measurement, such as when the power supply is holding voltage on a capacitor, any HV probe and DVM combination can be used. The Fluke 80K-40 probe with any 10M input resistance DVM is adequate up to 40kV. Building a simple resistor divider using appropriate HV resistors is also very straightforward. Keep in mind that all HV resistors, including the one in the Fluke probe, exhibit a negative voltage coefficient, changing by up to 4% from zero to max. voltage. De-rating the resistors and calibrating at the operating point solves this problem. The value of the resistor R1 and R2 (Figure 5.3) can be calculated as follows: VM = R2 x Vo R1 + R 2 where Vo is the High Voltage being measured. Making a pulsed measurement with an oscilloscope requires a compensated HV probe having a wide bandwidth. Simply connecting a DC probe, through the proper resistance, into a scope yields a slow response only adequate for low rep. rate systems. As with DC probes, the pulsed probe resistor voltage coefficient is a problem. In addition, damage to the resistors can occur during pulsing due to high electric field gradients. Also, stray capacitance to nearby objects can significantly alter the pulse response. For a highperformance, shielded probe to 40KV use a Tektronix P6015 or Ross Engineering VD60-8.3-A-K-LB. Measurements accurate to better than 0.1% can be achieved using a bias technique. For example, if a 40V signal (40kV divided by 1000) is to be measured accurately, the minus input of the DVM would be biased up 40V. The original signal, with respect to ground, is fed to the plus input of the DVM. The bias can be measured accurately for absolute measurements, or relative measurements read directly as the line or load is varied. In the same manner, an oscilloscope return can be biased for accurate peak measurements during pulsing. 19 83-493-001 Rev. P Figure 5-3 HV Bias Measurements 5.5 DETERMINING AC LINE CURRENT P IL = Line current IL = VL PF X EFF P = Average output power VL = Line voltage PF = Power factor (.65 min) EFF = 0.85 Ex: A 152A operating from 115V – 10% and delivering 1000W average. IL = 1000 x 0.9 =17.5 A (115)(.65)(0.85) When charging very large capacitor banks requiring many seconds or minutes to reach end-of-charge, the power supply will display a load fault and go into a 50% duty cycle protection mode. If this feature is defeated and the power supply is allowed to charge for an extended period, the peak output power, not the average power, must be used to determine line current. (See Section 5.7). 5.6 CONTINUOUS HV DC OPERATION (CONSTANT VOLTAGE) The 500A/102A/152A/202A supplies can be used as a constant voltage supply by the addition of an external filter capacitor. The value of this capacitor will determine the ripple voltage on the DC output. ∆ VPK − PK = 1.4( Po max) Vo)(Co)( Fs ) Where: Po max = Maximum output power in watts Vo = Output voltage in volts Co = Total output capacitance in microfarads Fs = Lowest switching frequency (40KHz) When operating as a DC supply care must be taken not to draw more than the J/sec rating of the unit. Also, if the filter capacitor is inadvertently shorted, it may ring which can damage the supply (Section 5.2). 20 83-493-001 Rev. P 5.7 LONG CHARGE TIME WITH POWER FACTOR CORRECTED (PFC) UNITS It is advised that you consult the factory if this type of operation is required. A special long charge programming adaptor is available for applications with charge times greater than 500 milliseconds. Visit the TDK-Lambda High Power website or contact customer service for details. 21 83-493-001 Rev. P CHAPTER 6 MAINTENANCE AND CALIBRATION 6.1 SAFETY PRECAUTIONS ONLY QUALIFIED PERSONNEL TRAINED IN THE SAFETY ASPECTS OF HIGH VOLTAGE SHOULD PERFORM CALIBRATION. The calibration steps described in this section require operation of the power supply with the cover removed. Proceed with extreme caution as hazardous voltages are exposed throughout the unit. Safety glasses must be worn to prevent serious injury in the event of a component failure (e.g., power transistors readily explode during fault conditions). Because the power supply does not receive proper cooling with the cover removed, it must be cooled by an external fan placed next to the supply to cool the inverter and HV section (min. air flow 100 CFM (2.83 M3/min.)) when operating at full power. Operation at full power with cover removed should be limited to less than five minutes. 6.2 MAINTENANCE No maintenance is required under normal operating conditions. Occasional vacuum or blow-out of the chassis may be required when operated in extremely dirty environments. The oil-filled HV assembly must not be opened. The oil and components have been specially cleaned and vacuum impregnated at the factory and the assembly hermetically sealed. Opening assembly will compromise performance and void warranty. HV Tanks must only be services at TDK-Lambda Americas Inc. 6.3 CALIBRATION Calibration of the output voltage is accomplished with trim pot RP4 located on the control board. This is the top PC board of the inverter assembly. RP4 is a 25 turn trim pot. Slowly turn it clockwise to decrease the output voltage for a given VPROGRAM. Factory set for 10V rated voltage for standard version. Refer to Sections 4.1 and 4.2 of product specification for Linearity and Accuracy. 22 83-493-001 Rev. P Product Name: UNIVOLT N 61 B Revision Date: 16 Mar 2015 Page 1 of 11 ______________________________________________________________________________________________________________________ SAFETY DATA SHEET SECTION 1 PRODUCT AND COMPANY IDENTIFICATION PRODUCT Product Name: UNIVOLT N 61 B Product Description: Base Oil and Additives Product Code: 201580102520, 730846-00, Intended Use: Electrical insulating oils 97P847 COMPANY IDENTIFICATION Supplier: EXXON MOBIL CORPORATION 22777 Springwoods Village Parkway Spring, TX. 77389 USA 24 Hour Health Emergency 609-737-4411 Transportation Emergency Phone 800-424-9300 or 703-527-3887 CHEMTREC Product Technical Information 800-662-4525 MSDS Internet Address http://www.exxon.com, http://www.mobil.com SECTION 2 HAZARDS IDENTIFICATION This material is hazardous according to regulatory guidelines (see (M)SDS Section 15). CLASSIFICATION: Aspiration toxicant: Category 1. LABEL: Pictogram: Signal Word: Danger Hazard Statements: H304: May be fatal if swallowed and enters airways. Precautionary Statements: P273: Avoid release to the environment.P301 + P310: IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician. P331: Do NOT induce vomiting. P391: Collect spillage.P405: Store locked up.P501: Dispose of contents and container in accordance with local regulations. Other hazard information: Product Name: UNIVOLT N 61 B Revision Date: 16 Mar 2015 Page 2 of 11 ______________________________________________________________________________________________________________________ HAZARD NOT OTHERWISE CLASSIFIED (HNOC): None as defined under 29 CFR 1910.1200. PHYSICAL / CHEMICAL HAZARDS No significant hazards. HEALTH HAZARDS Frequent or prolonged contact may defat and dry the skin, leading to discomfort and dermatitis. May be irritating to the eyes, nose, throat, and lungs. ENVIRONMENTAL HAZARDS Expected to be toxic to aquatic organisms. May cause long-term adverse effects in the aquatic environment. NFPA Hazard ID: HMIS Hazard ID: Health: Health: 1 1* Flammability: Flammability: 1 1 Reactivity: Reactivity: 0 0 NOTE: This material should not be used for any other purpose than the intended use in Section 1 without expert advice. Health studies have shown that chemical exposure may cause potential human health risks which may vary from person to person. SECTION 3 COMPOSITION / INFORMATION ON INGREDIENTS This material is defined as a mixture. Hazardous Substance(s) or Complex Substance(s) required for disclosure Name 2,6-DI-TERT-BUTYL-P-CRESOL CAS# 128-37-0 Concentration* 1 - < 5% HYDROTREATED LIGHT NAPHTHENIC DISTILLATE (PETROLEUM) 64742-53-6 90 - < 100% GHS Hazard Codes H400(M factor 1), H410(M factor 1) H304 * All concentrations are percent by weight unless material is a gas. Gas concentrations are in percent by volume. As per paragraph (i) of 29 CFR 1910.1200, formulation is considered a trade secret and specific chemical identity and exact percentage (concentration) of composition may have been withheld. Specific chemical identity and exact percentage composition will be provided to health professionals, employees, or designated representatives in accordance with applicable provisions of paragraph (i). SECTION 4 FIRST AID MEASURES INHALATION Remove from further exposure. For those providing assistance, avoid exposure to yourself or others. Use adequate respiratory protection. If respiratory irritation, dizziness, nausea, or unconsciousness occurs, seek immediate medical assistance. If breathing has stopped, assist ventilation with a mechanical device or use mouth-to-mouth resuscitation. SKIN CONTACT Wash contact areas with soap and water. Remove contaminated clothing. Launder contaminated clothing before reuse. Product Name: UNIVOLT N 61 B Revision Date: 16 Mar 2015 Page 3 of 11 ______________________________________________________________________________________________________________________ EYE CONTACT Flush thoroughly with water. If irritation occurs, get medical assistance. INGESTION Seek immediate medical attention. Do not induce vomiting. NOTE TO PHYSICIAN If ingested, material may be aspirated into the lungs and cause chemical pneumonitis. Treat appropriately. SECTION 5 FIRE FIGHTING MEASURES EXTINGUISHING MEDIA Appropriate Extinguishing Media: Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames. Inappropriate Extinguishing Media: Straight Streams of Water FIRE FIGHTING Fire Fighting Instructions: Evacuate area. Prevent runoff from fire control or dilution from entering streams, sewers, or drinking water supply. Firefighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA). Use water spray to cool fire exposed surfaces and to protect personnel. Hazardous Combustion Products: combustion products Aldehydes, Oxides of carbon, Sulfur oxides, Smoke, Fume, Incomplete FLAMMABILITY PROPERTIES Flash Point [Method]: >145°C (293°F) [ASTM D-92] Flammable Limits (Approximate volume % in air): LEL: N/D Autoignition Temperature: >315°C (599°F) SECTION 6 UEL: N/D ACCIDENTAL RELEASE MEASURES NOTIFICATION PROCEDURES In the event of a spill or accidental release, notify relevant authorities in accordance with all applicable regulations. US regulations require reporting releases of this material to the environment which exceed the applicable reportable quantity or oil spills which could reach any waterway including intermittent dry creeks. The National Response Center can be reached at (800)424-8802. PROTECTIVE MEASURES Avoid contact with spilled material. Warn or evacuate occupants in surrounding and downwind areas if required due to toxicity or flammability of the material. See Section 5 for fire fighting information. See the Hazard Identification Section for Significant Hazards. See Section 4 for First Aid Advice. See Section 8 for advice on the minimum requirements for personal protective equipment. Additional protective measures may be necessary, depending on the specific circumstances and/or the expert judgment of the emergency responders. For emergency responders: Respiratory protection: respiratory protection will be necessary only in special cases, e.g., formation of mists. Half-face or full-face respirator with filter(s) for dust/organic vapor or Self Contained Breathing Apparatus (SCBA) can be used depending on the size of spill and potential level of Product Name: UNIVOLT N 61 B Revision Date: 16 Mar 2015 Page 4 of 11 ______________________________________________________________________________________________________________________ exposure. If the exposure cannot be completely characterized or an oxygen deficient atmosphere is possible or anticipated, SCBA is recommended. Work gloves that are resistant to hydrocarbons are recommended. Gloves made of polyvinyl acetate (PVA) are not water-resistant and are not suitable for emergency use. Chemical goggles are recommended if splashes or contact with eyes is possible. Small spills: normal antistatic work clothes are usually adequate. Large spills: full body suit of chemical resistant, antistatic material is recommended. SPILL MANAGEMENT Land Spill: Stop leak if you can do it without risk. Recover by pumping or with suitable absorbent. Water Spill: Stop leak if you can do it without risk. Confine the spill immediately with booms. Warn other shipping. Remove from the surface by skimming or with suitable absorbents. Seek the advice of a specialist before using dispersants. Water spill and land spill recommendations are based on the most likely spill scenario for this material; however, geographic conditions, wind, temperature, (and in the case of a water spill) wave and current direction and speed may greatly influence the appropriate action to be taken. For this reason, local experts should be consulted. Note: Local regulations may prescribe or limit action to be taken. ENVIRONMENTAL PRECAUTIONS Large Spills: Dike far ahead of liquid spill for later recovery and disposal. Prevent entry into waterways, sewers, basements or confined areas. SECTION 7 HANDLING AND STORAGE HANDLING Avoid contact with skin. Prevent small spills and leakage to avoid slip hazard. Material can accumulate static charges which may cause an electrical spark (ignition source). When the material is handled in bulk, an electrical spark could ignite any flammable vapors from liquids or residues that may be present (e.g., during switch-loading operations). Use proper bonding and/or ground procedures. However, bonding and grounds may not eliminate the hazard from static accumulation. Consult local applicable standards for guidance. Additional references include American Petroleum Institute 2003 (Protection Against Ignitions Arising out of Static, Lightning and Stray Currents) or National Fire Protection Agency 77 (Recommended Practice on Static Electricity) or CENELEC CLC/TR 50404 (Electrostatics - Code of practice for the avoidance of hazards due to static electricity). Static Accumulator: This material is a static accumulator. STORAGE The container choice, for example storage vessel, may effect static accumulation and dissipation. Do not store in open or unlabelled containers. SECTION 8 EXPOSURE CONTROLS / PERSONAL PROTECTION EXPOSURE LIMIT VALUES Exposure limits/standards (Note: Exposure limits are not additive) Substance Name 2,6-DI-TERT-BUTYL-P-CRESOL Form Inhalable fraction and Limit / Standard TWA 2 mg/m3 NOTE N/A Source ACGIH Product Name: UNIVOLT N 61 B Revision Date: 16 Mar 2015 Page 5 of 11 ______________________________________________________________________________________________________________________ vapor Mist. HYDROTREATED LIGHT NAPHTHENIC DISTILLATE (PETROLEUM) HYDROTREATED LIGHT NAPHTHENIC DISTILLATE (PETROLEUM) HYDROTREATED LIGHT NAPHTHENIC DISTILLATE (PETROLEUM) TWA 5 mg/m3 N/A OSHA Z1 Inhalable fraction. TWA 5 mg/m3 N/A ACGIH Mist. TWA 5 mg/m3 N/A ACGIH Exposure limits/standards for materials that can be formed when handling this product: When mists/aerosols can occur the following are recommended: 5 mg/m³ - ACGIH TLV (inhalable fraction), 5 mg/m³ - OSHA PEL. NOTE: Limits/standards shown for guidance only. Follow applicable regulations. No biological limits allocated. ENGINEERING CONTROLS The level of protection and types of controls necessary will vary depending upon potential exposure conditions. Control measures to consider: No special requirements under ordinary conditions of use and with adequate ventilation. PERSONAL PROTECTION Personal protective equipment selections vary based on potential exposure conditions such as applications, handling practices, concentration and ventilation. Information on the selection of protective equipment for use with this material, as provided below, is based upon intended, normal usage. Respiratory Protection: If engineering controls do not maintain airborne contaminant concentrations at a level which is adequate to protect worker health, an approved respirator may be appropriate. Respirator selection, use, and maintenance must be in accordance with regulatory requirements, if applicable. Types of respirators to be considered for this material include: No special requirements under ordinary conditions of use and with adequate ventilation. For high airborne concentrations, use an approved supplied-air respirator, operated in positive pressure mode. Supplied air respirators with an escape bottle may be appropriate when oxygen levels are inadequate, gas/vapor warning properties are poor, or if air purifying filter capacity/rating may be exceeded. Hand Protection: Any specific glove information provided is based on published literature and glove manufacturer data. Glove suitability and breakthrough time will differ depending on the specific use conditions. Contact the glove manufacturer for specific advice on glove selection and breakthrough times for your use conditions. Inspect and replace worn or damaged gloves. The types of gloves to be considered for this material include: If prolonged or repeated contact is likely, chemical resistant gloves are recommended. If contact with forearms is likely, wear gauntlet style gloves. Eye Protection: If contact is likely, safety glasses with side shields are recommended. Skin and Body Protection: Any specific clothing information provided is based on published literature or manufacturer data. The types of clothing to be considered for this material include: Product Name: UNIVOLT N 61 B Revision Date: 16 Mar 2015 Page 6 of 11 ______________________________________________________________________________________________________________________ If prolonged or repeated contact is likely, chemical, and oil resistant clothing is recommended. Specific Hygiene Measures: Always observe good personal hygiene measures, such as washing after handling the material and before eating, drinking, and/or smoking. Routinely wash work clothing and protective equipment to remove contaminants. Discard contaminated clothing and footwear that cannot be cleaned. Practice good housekeeping. ENVIRONMENTAL CONTROLS Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions. SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES Note: Physical and chemical properties are provided for safety, health and environmental considerations only and may not fully represent product specifications. Contact the Supplier for additional information. GENERAL INFORMATION Physical State: Liquid Color: Pale Yellow Odor: Characteristic Odor Threshold: N/D IMPORTANT HEALTH, SAFETY, AND ENVIRONMENTAL INFORMATION Relative Density (at 15 °C): 0.883 Flammability (Solid, Gas): N/A Flash Point [Method]: >145°C (293°F) [ASTM D-92] Flammable Limits (Approximate volume % in air): LEL: N/D UEL: N/D Autoignition Temperature: >315°C (599°F) Boiling Point / Range: N/A Decomposition Temperature: N/D Vapor Density (Air = 1): > 5 at 101 kPa [Estimated] Vapor Pressure: < 0.013 kPa (0.1 mm Hg) at 20 °C [Estimated] Evaporation Rate (n-butyl acetate = 1): N/D pH: N/A Log Pow (n-Octanol/Water Partition Coefficient): > 6.5 [Estimated] Solubility in Water: Negligible Viscosity: 8.18 cSt (8.18 mm2/sec) at 40 °C | 2.18 cSt (2.18 mm2/sec) at 100°C Oxidizing Properties: See Hazards Identification Section. OTHER INFORMATION Freezing Point: N/D Melting Point: -55°C (-67°F) Pour Point: -40°C (-40°F) DMSO Extract (mineral oil only), IP-346: SECTION 10 REACTIVITY: See sub-sections below. < 3 %wt STABILITY AND REACTIVITY Product Name: UNIVOLT N 61 B Revision Date: 16 Mar 2015 Page 7 of 11 ______________________________________________________________________________________________________________________ STABILITY: Material is stable under normal conditions. CONDITIONS TO AVOID: Excessive heat. High energy sources of ignition. MATERIALS TO AVOID: Strong oxidizers HAZARDOUS DECOMPOSITION PRODUCTS: Material does not decompose at ambient temperatures. POSSIBILITY OF HAZARDOUS REACTIONS: Hazardous polymerization will not occur. SECTION 11 TOXICOLOGICAL INFORMATION INFORMATION ON TOXICOLOGICAL EFFECTS Hazard Class Inhalation Acute Toxicity: No end point data for material. Irritation: No end point data for material. Ingestion Acute Toxicity: No end point data for material. Skin Acute Toxicity: No end point data for material. Skin Corrosion/Irritation: No end point data for material. Eye Serious Eye Damage/Irritation: No end point data for material. Sensitization Respiratory Sensitization: No end point data for material. Skin Sensitization: No end point data for material. Aspiration: Data available. Germ Cell Mutagenicity: No end point data for material. Carcinogenicity: No end point data for material. Reproductive Toxicity: No end point data for material. Lactation: No end point data for material. Specific Target Organ Toxicity (STOT) Single Exposure: No end point data for material. Repeated Exposure: No end point data for material. TOXICITY FOR SUBSTANCES Conclusion / Remarks Minimally Toxic. Based on assessment of the components. Elevated temperatures or mechanical action may form vapors, mist, or fumes which may be irritating to the eyes, nose, throat, or lungs. Minimally Toxic. Based on assessment of the components. Minimally Toxic. Based on assessment of the components. May dry the skin leading to discomfort and dermatitis. Based on assessment of the components. May cause mild, short-lasting discomfort to eyes. Based on assessment of the components. Not expected to be a respiratory sensitizer. Not expected to be a skin sensitizer. Based on assessment of the components. May be fatal if swallowed and enters airways. Based on physico-chemical properties of the material. Not expected to be a germ cell mutagen. Based on assessment of the components. Not expected to cause cancer. Based on assessment of the components. Not expected to be a reproductive toxicant. Based on assessment of the components. Not expected to cause harm to breast-fed children. Not expected to cause organ damage from a single exposure. Not expected to cause organ damage from prolonged or repeated exposure. Based on assessment of the components. Product Name: UNIVOLT N 61 B Revision Date: 16 Mar 2015 Page 8 of 11 ______________________________________________________________________________________________________________________ NAME 2,6-DI-TERT-BUTYL-P-CRESOL ACUTE TOXICITY Oral Lethality: LD50 0.89 g/kg (Rat) OTHER INFORMATION For the product itself: Prolonged and/or repeated skin contact with low viscosity materials may defat the skin resulting in possible irritation and dermatitis. Small amounts of liquid aspirated into the lungs during ingestion or from vomiting may cause chemical pneumonitis or pulmonary edema. Contains: Base oil severely refined: Not carcinogenic in animal studies. Representative material passes IP-346, Modified Ames test, and/or other screening tests. Dermal and inhalation studies showed minimal effects; lung non-specific infiltration of immune cells, oil deposition and minimal granuloma formation. Not sensitizing in test animals. The following ingredients are cited on the lists below: None. 1 = NTP CARC 2 = NTP SUS SECTION 12 --REGULATORY LISTS SEARCHED-3 = IARC 1 5 = IARC 2B 4 = IARC 2A 6 = OSHA CARC ECOLOGICAL INFORMATION The information given is based on data available for the material, the components of the material, and similar materials. ECOTOXICITY Material -- Expected to be toxic to aquatic organisms. May cause long-term adverse effects in the aquatic environment. MOBILITY Base oil component -- Low solubility and floats and is expected to migrate from water to the land. Expected to partition to sediment and wastewater solids. PERSISTENCE AND DEGRADABILITY Biodegradation: Base oil component -- Expected to be inherently biodegradable BIOACCUMULATION POTENTIAL Base oil component -- Has the potential to bioaccumulate, however metabolism or physical properties may reduce the bioconcentration or limit bioavailability. Product Name: UNIVOLT N 61 B Revision Date: 16 Mar 2015 Page 9 of 11 ______________________________________________________________________________________________________________________ SECTION 13 DISPOSAL CONSIDERATIONS Disposal recommendations based on material as supplied. Disposal must be in accordance with current applicable laws and regulations, and material characteristics at time of disposal. DISPOSAL RECOMMENDATIONS Product is suitable for burning in an enclosed controlled burner for fuel value or disposal by supervised incineration at very high temperatures to prevent formation of undesirable combustion products. Protect the environment. Dispose of used oil at designated sites. Minimize skin contact. Do not mix used oils with solvents, brake fluids or coolants. REGULATORY DISPOSAL INFORMATION RCRA Information: The unused product, in our opinion, is not specifically listed by the EPA as a hazardous waste (40 CFR, Part 261D), nor is it formulated to contain materials which are listed as hazardous wastes. It does not exhibit the hazardous characteristics of ignitability, corrositivity or reactivity and is not formulated with contaminants as determined by the Toxicity Characteristic Leaching Procedure (TCLP). However, used product may be regulated. Empty Container Warning Empty Container Warning (where applicable): Empty containers may contain residue and can be dangerous. Do not attempt to refill or clean containers without proper instructions. Empty drums should be completely drained and safely stored until appropriately reconditioned or disposed. Empty containers should be taken for recycling, recovery, or disposal through suitably qualified or licensed contractor and in accordance with governmental regulations. DO NOT PRESSURISE, CUT, WELD, BRAZE, SOLDER, DRILL, GRIND, OR EXPOSE SUCH CONTAINERS TO HEAT, FLAME, SPARKS, STATIC ELECTRICITY, OR OTHER SOURCES OF IGNITION. THEY MAY EXPLODE AND CAUSE INJURY OR DEATH. SECTION 14 TRANSPORT INFORMATION LAND (DOT): Not Regulated for Land Transport LAND (TDG): Not Regulated for Land Transport SEA (IMDG): Not Regulated for Sea Transport according to IMDG-Code Marine Pollutant: AIR (IATA): SECTION 15 No Not Regulated for Air Transport REGULATORY INFORMATION OSHA HAZARD COMMUNICATION STANDARD: HazCom 2012, 29 CFR 1910.1200. This material is considered hazardous in accordance with OSHA Product Name: UNIVOLT N 61 B Revision Date: 16 Mar 2015 Page 10 of 11 ______________________________________________________________________________________________________________________ Listed or exempt from listing/notification on the following chemical inventories: KECI, PICCS, TSCA AICS, DSL, ENCS, IECSC, EPCRA SECTION 302: This material contains no extremely hazardous substances. SARA (311/312) REPORTABLE HAZARD CATEGORIES: Immediate Health. Delayed Health. SARA (313) TOXIC RELEASE INVENTORY: This material contains no chemicals subject to the supplier notification requirements of the SARA 313 Toxic Release Program. The following ingredients are cited on the lists below: Chemical Name 2,6-DI-TERT-BUTYL-P-CRESOL HYDROTREATED LIGHT NAPHTHENIC DISTILLATE (PETROLEUM) 1 = ACGIH ALL 2 = ACGIH A1 3 = ACGIH A2 4 = OSHA Z 5 = TSCA 4 CAS Number 128-37-0 64742-53-6 List Citations 1, 13, 16, 17, 18 1, 4, 13, 17, 18 --REGULATORY LISTS SEARCHED-6 = TSCA 5a2 11 = CA P65 REPRO 7 = TSCA 5e 12 = CA RTK 8 = TSCA 6 13 = IL RTK 9 = TSCA 12b 14 = LA RTK 10 = CA P65 CARC 15 = MI 293 16 = MN RTK 17 = NJ RTK 18 = PA RTK 19 = RI RTK Code key: CARC=Carcinogen; REPRO=Reproductive SECTION 16 OTHER INFORMATION N/D = Not determined, N/A = Not applicable KEY TO THE H-CODES CONTAINED IN SECTION 3 OF THIS DOCUMENT (for information only): H304: May be fatal if swallowed and enters airways; Aspiration, Cat 1 H400: Very toxic to aquatic life; Acute Env Tox, Cat 1 H410: Very toxic to aquatic life with long lasting effects; Chronic Env Tox, Cat 1 THIS SAFETY DATA SHEET CONTAINS THE FOLLOWING REVISIONS: Updates made in accordance with implementation of GHS requirements. ----------------------------------------------------------------------------------------------------------------------------------------------------The information and recommendations contained herein are, to the best of ExxonMobil's knowledge and belief, accurate and reliable as of the date issued. You can contact ExxonMobil to insure that this document is the most current available from ExxonMobil. The information and recommendations are offered for the user's consideration and examination. It is the user's responsibility to satisfy itself that the product is suitable for the intended use. If buyer repackages this product, it is the user's responsibility to insure proper health, safety and other necessary information is Product Name: UNIVOLT N 61 B Revision Date: 16 Mar 2015 Page 11 of 11 ______________________________________________________________________________________________________________________ included with and/or on the container. Appropriate warnings and safe-handling procedures should be provided to handlers and users. Alteration of this document is strictly prohibited. Except to the extent required by law, re-publication or retransmission of this document, in whole or in part, is not permitted. The term, "ExxonMobil" is used for convenience, and may include any one or more of ExxonMobil Chemical Company, Exxon Mobil Corporation, or any affiliates in which they directly or indirectly hold any interest. ----------------------------------------------------------------------------------------------------------------------------------------------------Internal Use Only MHC: 2A, 0B, 0, 0, 1, 1 PPEC: C DGN: 2011629XUS (548632) ----------------------------------------------------------------------------------------------------------------------------------------------------Copyright 2002 Exxon Mobil Corporation, All rights reserved 01000721revF.sch-1 - Fri Nov 06 08:45:09 2015 AEH A Hague 3/21/16 GS 3/2/16 A Hague 3/21/16 B Huhn 3/16/16 A Hague 3/21/16 A Hague 3/21/16 01000721revF.sch-2 - Fri Nov 06 08:45:10 2015
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Andy Tydeman Company : Lambda Americas Create Date : 2016:11:08 11:35:17-05:00 Modify Date : 2017:12:07 16:19:48-05:00 Source Modified : D:20161104195714 Subject : Operating Manual for 500A/102A/152A/202A Power Supply Has XFA : No Language : EN-US Tagged PDF : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2017:12:07 16:19:48-05:00 Creator Tool : Acrobat PDFMaker 11 for Word Document ID : uuid:6871ab0f-3dd3-4285-8d75-560c92d6b3d9 Instance ID : uuid:f37190fb-267f-4eb4-a5a4-fd45f278c929 Format : application/pdf Title : Operating Manual for 500A/102A/152A/202A Power Supply Description : Operating Manual for 500A/102A/152A/202A Power Supply Creator : Andy Tydeman Producer : Adobe PDF Library 11.0 Page Layout : OneColumn Page Count : 60 Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools