90899 Manual For The 7 Function Digital Multimeter

User Manual: Manual for the 90899 7 Function Digital Multimeter Digital Multimeter - Save on this 7 Function Digital Multimeter

Open the PDF directly: View PDF PDF.
Page Count: 7

7 FUNCTION DIGITAL MULTIMETER
OPERATING INSTRUCTIONS
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our Web site at http://www.harborfreight.com
Copyright© 2004 by Harbor Freight Tools®. All rights reserved. No portion
of this manual or any artwork contained herein may be reproduced in any
shape or form without the express written consent of Harbor Freight Tools.
For technical questions and replacement parts, please call 1-800-444-3353
90899
SKU 90899 For replacement parts, please call 1-800-444-3353. Page 2
Specifications
Save This Manual
You will need the manual for the safety warnings and
precautions, and operating and maintenance procedures.
Keep your invoice with this manual. Write the invoice number
on the inside of the front cover. Keep the manual and invoice
in a safe and dry place for future reference.
Safety Warnings and Precautions
WARNING: When using tool, basic safety precautions should always be
followed to reduce the risk of personal injury and damage to
equipment.
METINOITPIRCSED
ycneuqerFzH054-54
spmACD002:segnaR µ0002/A µA01,Am002/Am02/A
ycaruccA002@( µD2±%3)A01@(;D2±%2.1
)Am002-A
egatloVCDV0001/002/02/Vm0002/Vm002:segnaR
ycaruccA;D1±%5.0)Vm002@(
;D1±%0.1)V002-Vm0002@(
D2±%0.1)
V0001@(
egatloVCAV057/002:segnaR
ycaruccAD01±%2.1)zH054-54(
ecnatsiseRmhOK0002/K002/K02/0002/002:segnaR
ycar
uccA;D2±%8.0)mhOK002-002@(
;D2±%0.1)mhOK0002@(
etaRgnilpmaSdnoceS/semit5.2
noitcetorPdaolrevOesuFV052/Am005
gnitcA-tsaF
erutarepmeTgnitarepOF°401-°23:egnaR
yalpsiD
1
/
2
-3hgih"
1
/
2
DCLtigid-
yrettaB)dedulcni(V9enO
thgieW.bl54.
serutaeF)PNPdnaNPN(rotsisnarT,sdaeLtseT"23
dna,noitcnuFgnitseT
yrettaB,noitcnuFgnitseT
tsujdAoreZdnaytiraloPcitamotuA
Warnings continued on page 3.
REV 12/06
SKU 90899 For replacement parts, please call 1-800-444-3353. Page 3
Read all instructions before using this tester!
1. Avoid working alone. If an accident happens, an assistant can
bring help.
2. Keep work area clean. Cluttered areas invite injuries.
3. Avoid electrical shock. Use extreme caution when using this tool
near uninsulated conductors or bus bars. Prevent body contact with
grounded surfaces such as pipes, radiators, ranges, and cabinet
enclosures when testing voltages.
4. Avoid damaging meter. Use only as specified in this manual.
5. Observe work area conditions. Do not test voltages in damp or
wet locations. Don’t expose to rain. Keep work area well lit.
6. Keep children away. Children must never be allowed in the work
area. Do not let them handle machines, tools, or extension cords.
7. Store idle equipment. When not in use, tools must be stored in a
dry location to inhibit rust. Always lock up tools and keep out of
reach of children.
8. Dress properly. Do not wear loose clothing or jewelry as they can
be caught in moving parts. Protective, electrically nonconductive
clothes and nonskid footwear are recommended when working. Wear
restrictive hair covering to contain long hair.
9. Use eye protection. Always wear ANSI approved impact safety
goggles.
10. Do not overreach. Keep proper footing and balance at all times. Do
not reach over or across electrical cables or frames.
11. Maintain tools with care. Ensure multimeter has a fresh battery.
Inspect test leads periodically and, if damaged, have them repaired
by an authorized technician.
12. Stay alert. Watch what you are doing, use common sense. Do not
operate any tool when you are tired.
13. Check for damaged parts. Before using any tool, any part that
appears damaged should be carefully checked to determine that it
will operate properly and perform its intended function. Check for any
broken parts and any other condition that may affect proper operation.
Any part that is damaged should be properly repaired or replaced by
a qualified technician. Do not use the tool if any switch does not operate
properly.
SKU 90899 For replacement parts, please call 1-800-444-3353. Page 4
Unpacking
When unpacking, make sure the following parts are included: Digital
Multimeter, and black and red Test Leads. If any parts are missing or broken, please
call Harbor Freight Tools at the number on the cover of this manual. If any part of the
machine is missing or broken, please call Harbor Freight Tools at the number on the
front cover as soon as possible.
15. Replacement parts and accessories. When servicing, use only
identical replacement parts. Use of any other parts will void the
warranty. Only use accessories intended for use with this tool.
Approved accessories are available from Harbor Freight Tools.
16. Do not operate tool if under the influence of alcohol or drugs.
Read warning labels on prescriptions to determine if your judgment
or reflexes are impaired while taking drugs. If there is any doubt, do
not operate the tool.
17. We recommend that only a licensed electrician work on high-
voltage or other potentially dangerous circuits.
Note: Performance of this tool may vary depending on condition of internal
battery.
Warning: The warnings, cautions, and instructions discussed
in this instruction manual cannot cover all possible
conditions and situations that may occur. It must be
understood by the operator that common sense and
caution are factors which cannot be built into this
product, but must be supplied by the operator.
Warning: This product contains or produces chemicals,
including lead, known to the State of California to
cause cancer and birth defects (or other
reproductive harm).
(California Health & Safety Code 25249.5 et seq.)
Operation
WARNING:ELECTRICAL SHOCK CAN CAUSE DEATH OR
INJURY. AVOID TOUCHING EXPOSED CONDUCTORS
OF ELECTRICITY.
Additional Multimeter Precautions
1. Do not test voltage on AC circuits higher than 750 volts.
2. Do not test voltage on DC circuits higher than 1000 volts.
3. Do not test current on circuits higher than 10 amps.
SKU 90899 For replacement parts, please call 1-800-444-3353. Page 5
4. Be careful not to
apply voltage to
the Test Leads
when they are
connected to the
COM (Bottom)
and VmA
(Center) Jacks
and the Multimeter
is in an Ohms
testing setting.
Damage can occur to the
multimeter or the fuse may
blow.
5. Do not switch between
testing modes with the
multimeter connected to a
circuit.
AC Voltage Measurements
Measure AC conductors carrying up to 750 VAC, 45-450 Hz.
1. Turn the Range Selector Switch to 750 ACV setting.
Always start with the highest range if the voltage is unknown.
2. Plug the red lead into the VmA (Center) Jack. Plug the black lead into the
COM (Bottom) Jack. Switch the Multimeter ON.
3. Carefully touch the exposed conductors with the tips of the probes to measure
the voltage (not amperes).
4. Read measurement.
If the voltage is less than 200 volts, set the Range Selector Switch to the
lower range.
5. When testing is complete, remove Test Leads and store with multimeter.
DC Voltage Measurements
Measure DC conductors carrying up to 1000 VDC.
1. Turn the Range Selector Switch to 1000 DCV setting.
2. Follow the directions above under “AC Voltage Measurements”, only use the
DC settings instead.
COM Jack Volt/Ohm/
mA Jack
DC AMP
Selection
Area
DC Volt
Selection
Area
Ohm
Selection
Area
Transistor
Selection
Area
ON/OFF
Switch
Control Layout
10A
Selection
Area/Jack
AC Volt Selection Area
Transistor
/hFE Jack
Diode
Selection Area
Battery
Test
Selection
Area
REV 11/04
SKU 90899 For replacement parts, please call 1-800-444-3353. Page 6
DC Current Measurements
Measure DC conductors carrying up to 10 amperes.
1. Turn the Range Selector Switch to the 10A position.
Always start with the highest range if the amperage is unknown.
2. Plug the red lead into the 10A (Top) Jack. Plug the black lead into the COM
(Bottom) Jack. Switch the Multimeter ON.
3. Carefully touch the exposed conductors with the tips of the probes to measure
the amperage.
Note: Amperage is always tested in series with the circuit under test.
4. Read measurement.
If the reading is less than .2 AMPs, switch the red lead to the VmA (Center)
Jack and set the Range Selector Switch to the 200 mA setting.
5. When testing is complete, remove Test Leads and store with multimeter.
Resistance Measurements
Measure circuit resistance up to 2000K Ohms.
WARNING: NEVER measure resistance on a circuit with voltage running through it.
1. Turn the Range Selector Switch to the 200 position.
2. Plug the red Test Lead into the VmA (Center) Jack. Plug the black Test
Lead into the Com (Bottom) Jack. Switch the Multimeter ON.
Short the Test Leads together. The meter should read “0” Ohms.
3. Touch the exposed conductors with the tips of the Test Leads.
4. Read measurement.
If the reading is “1”, set the Range Selector Switch to the next higher Ohm
() position.
Transistor (hFE) Measurements
Test transistors to ensure proper function.
1. Turn the Range Selector Switch to the hFE position.
Switch the Multimeter ON.
2. Insert the transistor pins into the appropriate hFE jack (NPN or PNP) according
to the EBC (Emitter, Base, Collector) sequence.
3. The meter will show the approximate hFE value.
Diode Measurement
Test the voltage drop in diodes.
1. Turn the Range Selector Switch to the Diode ( ) position.
2. Plug the red Test Lead into the VmA (Center) Jack. Plug the black Test
Lead into the Com (Bottom) Jack. Switch the Multimeter ON.
3. Connect the red probe to the anode of the diode and the black to the cathode.
SKU 90899 For replacement parts, please call 1-800-444-3353. Page 7
NOTE: No replacement parts are available for this tool.
Battery/Fuse Replacement
To replace the battery or fuse:
1. Remove the Test Leads from the multimeter.
2. Turn the unit over.
3. Remove both screws using a Philips screwdriver.
4. Remove back cover.
5. Pull battery/fuse out of unit and replace with the same.
(9V battery or 500mA/250V fast-acting fuse)
6. Replace cover and retighten screws.
Maintenance
1. Wipe unit with a slightly damp cloth using a light detergent. Do not use solvents
or abrasives.
2. Remove battery if not in use for long periods.
3. Store unit in a dry location.
4. Other than the battery and fuse, there are no replaceable parts on this unit.
Repairs should be done by a qualified technician.
REV 08/04;03/05;12/06
4. The approximate forward voltage drop of the diode will be displayed in
mV. If the connection is reversed only “1” will be shown.
Battery Charge Measurement
Test the amount of charge left in batteries.
NOTE: This setting is for testing the charge of small 9V or 1.5V batteries only.
Never use this setting to test automotive or lead-acid batteries. The high
current could cause damage to the meter and/or cause severe personal injury.
Use the appropriate DC Voltage setting to test the open current voltage of
such batteries instead.
1. Turn the Range Selector Switch to the Battery ( ) position.
2. Plug the red Test Lead into the VmA (Center) Jack. Plug the black Test
Lead into the Com (Bottom) Jack. Switch the Multimeter ON.
3. Connect the red probe to the positive terminal of the battery and the black to
the negative terminal.
4. The battery amperage under a load of 370 m will be displayed to a
resolution of .1mA.
5. Normal amperage: For a standard 9V (6LR61) battery = 25 mA
For a 1.5 V “AA” (LR6) battery = 4 mA

Navigation menu