9109 FX0 Analog Voice APM Installation Instruction A2 GN14 20

9109-A2-GN14-20 9109-A2-GN14-20

User Manual: 9109-A2-GN14-20

Open the PDF directly: View PDF PDF.
Page Count: 11

Download9109 FX0 Analog Voice APM Installation Instruction - 9109-A2-GN14-20
Open PDF In BrowserView PDF
TM

9109 FXO Analog Voice Application Module (APM)
Installation Instructions
Document Number 9109-A2-GN14-20
May 1999

Product Documentation on the World Wide Web
We provide complete product documentation online. This lets you search the
documentation for specific topics and print only what you need, reducing the waste of
surplus printing. It also helps us maintain competitive prices for our products.
Complete documentation for this product is available at www.paradyne.com.
Select Library → Technical Manuals → NextEDGE Multiservices Access System.
Select the following document:
9191-A2-GH30
NextEDGE Multiservices Access System Technical Reference
To request a paper copy of a Paradyne document:
 Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396)
 Outside the U.S.A., call 1-727-530-8623

Before You Begin
Make sure you have:
 The housing and any associated hardware installed and powered up.
 A Network Access Module (NAM) installed in Slot 01 and connected to the

network.
 Applicable cables.
 An M66 block.
 A small Phillips screwdriver (#1 or #2) to install the APM
 A small, flat-blade screwdriver to install the I/O card and cable connections

See the Technical Reference for additional information on:


Troubleshooting



Technical Specifications



Cables, Connectors, and Pin Assignments

1

Package Checklist
Verify that your package contains the following:
 FXO Analog Voice Application Module (APM)
 Voice I/O card
 Cable tie and anchor
 Affidavit Requirements for Connection to Digital Service

When your equipment arrives, inspect it for physical damage and tighten any screws
that may have worked loose. Contact your sales representative immediately if there are
any signs of shipping damage or if anything is missing from your package. Otherwise,
proceed with the installation.

Cables You May Need to Order
The following cables and cable assemblies are specifically for this product. See the
Technical Reference for cable pinout information.

If connecting an
M66 block to . . .

Order a . . .

Feature No.

A device located within
three feet of the system

Voice Cable,
amphenol plug-to-amphenol plug,
25 twisted pairs (6 feet/1.9 meters)

9008-F1-531

A device located within
25 feet of the system

Voice Cable,
amphenol plug-to-amphenol plug,
25 twisted pairs, and

9008-F1-531

Extension Cable,
amphenol socket-to-amphenol plug
(25 feet/7.6 meters)

9008-F1-532

Cable Assembly for FXS and FXO
APMs, 3-amphenol plug-to1-amphenol plug (6 feet/1.9 meters)

9008-F1-534

Extension Cable,
amphenol socket-to-amphenol plug,
if needed (25 feet/7.6 meters)

9008-F1-532

Three FXO cards

2

! HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from
damage due to electrostatic discharge (ESD) during normal
operation. When performing installation procedures,
however, take proper static control precautions to
prevent damage to equipment. If you are not sure
of the proper static control precautions, contact
your nearest sales or service representative.

496-15149

Installing the I/O Card
The I/O card provides the APM with voice channel connectivity. The I/O card inserts
directly behind the APM that it supports. Slot numbers are identical to facilitate correct
installation.
1. Remove the I/O card from the shipping box. Handle only by the top
and bottom edges to avoid damaging the card.
2. At the rear of the housing, align the I/O card with the upper and lower
tracks of the slot. Push gently towards the midplane until it stops and
you cannot push the card any further.

5-Slot

9109
Voice

2-Slot
Rear View

VOIC
POR E
T

Screws
98-15150-02

3. There are two captive screws on the I/O card. Alternately tighten
each screw until both are snug.

496-15168

3

Connecting to Analog Voice Equipment
The eight FXO ports support only 2-wire voice circuits. Connect the cables as described
below.
1. Remove the bottom Jack-screw from the I/O card, below the 50-position interface.
2. Align the anchor mount (provided) with the screw hole, reinsert the Jack-screw, and
tighten it securely.
3. Feed the cable tie provided through the anchor mount, about 2/3 of the way.
4. Plug in the 50-pin end of the cable, and secure the connector by screwing the top
cable screw into the top Jack-screw.
5. Wrap the long end of the cable tie around the cable, and feed it through the other
end of the cable tie, tightening the cable to the anchor mount, then clipping the
excess.

50-Pin
Connector

Anchor
Mount

Jack-Screw
496-15181

6. Connect the other end of the cable to the M66 block.

4

The following illustrations show fully connected voice ports.

M66 Block

497-15151-01

M 66 B lock

Vo ice A P M s
P3
P2
P1

P4

97-15171-02

5

M 66 B locks
TX

RX

E&M

S ig n a l G ro u n d
a n d B a tte ry

Vo ice A P M s
P3
P2
P1
P4

P5

P6

P7

97-15172-02

! WARNING:
In order to maintain compliance with Part 68, FCC Rules and Industry
Canada’s CS-03 Specification, the transmit gain settings associated with the
FXO Voice APM must be set to ensure that:


The absolute signal power of the encoded analog signals, other than live
voice and network control signaling, will not exceed –12 dBm when
averaged over any 3-second interval.



For network control signals (such as DTMF), the level will not exceed
– 3 dBm.

The FXO voice lines are to be connected to locally attached equipment only.
Under no circumstances should voice lines be used on exposed (outside)
plant lines.
See the Technical Reference to configure for a voice application.

6

Removing the Housing’s Bezel
1. Depress the latch at the top of the housing to open the bezel.
2. Lift upward to remove the bezel from the two slots at the bottom of the housing.

496-15123

Save the bezel so it can be reattached once the APM has been installed.

NOTE:
The power supply is visible once the bezel is
removed. It provides low voltage power to the
housing and its cards.

Power
Supply

! WARNING:
If you need to remove the power supply
module, you must unplug the power cord
from the power receptacle and from the rear
of the housing before attempting to remove
the module.

Front View
(without Bezel)
98-15174-01

7

Installing the APM
The APM can be installed in any slot except Slot 01.

CAUTION:
You must insert the FXO APM in the correct slot so that it mates with its
matching I/O card. APMs are keyed so that they mate only with their matching
I/O cards.
1. Remove the filler panel, if applicable. See the installation instructions that came
with your housing for information.
2. Remove the APM from the shipping box. Handle only by the top and bottom edges
to avoid damaging the card.
3. At the front of the housing, align the APM with the upper and lower tracks of the
selected slot.

5-Slot

2-Slot

Ejector
Latches

Ejector
Latches

Front View

98-15152-02

4. Slide the APM into the tracks until it seats with the midplane connectors. Be careful
not to force the card or bend any pins.
5. Close both the upper and lower ejector latches on the housing to lock in place, then
tighten the captive screws.

Reinstalling the Bezel
1. Insert the bezel into the two slots at the bottom of the front of the housing.
2. Snap the bezel in place using the latch at the top.

8

Removing/Replacing a Card
Card removal procedures differ, depending on whether you are removing the APM or
I/O card.

NOTE:
You can insert or remove the APM and its associated I/O card without powering off
the equipment and interrupting data flow through other cards in the network.

Removing/Replacing an APM
1. Remove the housing’s bezel, if applicable. See the installation instructions that
came with your housing for information.
2. Remove the captive screws from the ejector latches on the housing.
3. Press open the ejector latches to disengage the card from the midplane.
4. Supporting the card by its edges, pull straight out until the card clears the housing.
5. Refer to Steps 3 – 5 of Installing the APM on page 8.

If the slot . . .

Then the . . .

Was previously unassigned

Configuration settings are the factory
defaults and are accessible from SNMP
and the user interface.

Was previously assigned

Existing configuration settings are used
and are accessible from SNMP and the
user interface.

Previously contained a different type of
APM

System generates a Module
Misconfiguration alarm for the given
slot. See the Technical Reference for
procedures in this situation.

9

Removing/Replacing an I/O Card
1. Remove the APM from the housing (see Removing/Replacing an APM on
page 9).
2. Remove the cables from the I/O card.
3. Using a small flat-blade screwdriver, loosen the upper and lower captive screws
fastening the card to the housing’s frame.
4. Gently pull the I/O card away from the midplane until it clears the housing.
5. Align the replacement card with the upper and lower tracks of the slot. Push gently
towards the midplane until it stops and you cannot push the card any further.
6. Alternately tighten each captive screw until the screws are all the way in.
7. Reattach the cables as appropriate.

Power-On
Refer to the installation instructions that came with your housing to power on the
equipment.

10

Warranty, Sales, Service, and Training Information
Contact your local sales representative, service representative, or distributor directly for
any help needed. For additional information concerning warranty, sales, service, repair,
installation, documentation, training, distributor locations, or Paradyne worldwide office
locations, use one of the following methods:
H

Internet: Visit the Paradyne World Wide Web site at www.paradyne.com.
(Be sure to register your warranty there. Select Service & Support →Warranty
Registration.)

H

Telephone: Call our automated system to receive current information by fax or to
speak with a company representative.
— Within the U.S.A., call 1-800-870-2221
— Outside the U.S.A., call 1-727-530-2340

Document Feedback
We welcome your comments and suggestions about this document. Please mail them
to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773,
or send e-mail to userdoc@eng.paradyne.com. Include the number and title of this
document in your correspondence. Please include your name and phone number if you
are willing to provide additional clarification.

Trademarks
All products and services mentioned herein are the trademarks, service marks,
registered trademarks or registered service marks of their respective owners.

Copyright E 1999 Paradyne Corporation

11



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 1999:06:03 14:58:49
Producer                        : Acrobat Distiller Command 2.1 for SunOS/Solaris (SPARC)
Title                           : 9109 FX0 Analog Voice APM Installation Instruction - 9109-A2-GN14-20
Author                          : Paradyne Corporation
Modify Date                     : 2000:08:16 16:11:22-04:00
Page Count                      : 11
Page Mode                       : UseOutlines
EXIF Metadata provided by EXIF.tools

Navigation menu