S Agilent 4155C Semiconductor Parameter Analyzer Agilent 4156C Precision Semiconductor Parameter Analyzer Data Sheet Introduction Agilent 4155C and 4156C Basic Functions • Set measurement and/or stress conditions • Control measurement and/or stress execution • Perform arithmetic calculations • Display measured and calculated results on the LCD display • Perform graphical analysis • Store and recall measurement setups, and measurement and graphical display data • Dump to printers or plotters for hardcopy output • Perform measurement and analysis with built-in instrument BASIC • Self test, Auto calibration Configuration The 4155C and 4156C both come standard with I/CV 2.1 Lite automation software. A PC-based instrument controller with I/CV Lite preinstalled and an Agilent 82357A USB/GPIB interface are also included with the standard configuration. You have the option of deleting the controller and cable from your order, but I/CV Lite is always included with both instruments. If you want the full version of I/CV 2.1, you can request the E5240BU upgrade kit when you order a 4155C or 4156C. For more information about the differences between I/CV 2.1 Lite and I/CV 2.1, please refer to the Agilent I/CV 2.1 Technical Overview, publication number 5988-8474EN. 4155C 4156C 4xMPSMU 4xHRSMU 2xVMU 2xVSU I/CV 2.1 Lite 2xVMU 2xVSU I/CV 2.1 Lite Standard PC-based controller and USB/GPIB interface SMU: Source Monitor Unit Display resolution: 6 digits at each current range (0.01fA display resolution at 10pA range) 2 HRSMU: High Resolution SMU (1fA/2µV to 100mA/100V) MPSMU: Medium Power SMU (10fA/2µV to 100mA/100V) HPSMU: High Power SMU (10fA/2µV to 1A/200V) VMU: Voltage Monitor Unit (0.2µV resolution in differential mode) VSU: Voltage Source Unit PGU: Pulse Generator Unit (1 channel) GNDU: Ground Unit 1 Minimum number of installable MPSMU or PGU is two. 2 Accuracy not guaranteed. Minimum guaranteedresolution is 1fA at 10pA range. 41501B (Optional) 2xPGU (Option)1 GNDU HPSMU (Option) or 2xMPSMU (Option)1 S1 Hardware Specification Condition The “supplemental” information and “typical” entries in the following specifications are not warranted, but provide useful information about the functions and performance of the instruments. The measurement and output accuracy are specified at the rear panel connector terminals when referenced to the Zero Check terminal under the following con-ditions: 1. 23° C ±5° C (double between 5° C to 18° C, and 28° C to 40° C if not noted otherwise) 2. After 40 minutes warm-up 3. Ambient temperature change less than ±1° C after auto calibration execution. 4. Integration time: medium or long 5. Filter: ON (for SMUs) 6. Kelvin connection (for HRSMU, HPSMU, and GNDU) 7. Calibration period: 1 year Agilent 4156C Precision Semiconductor Parameter Analyzer HRSMU (High Resolution SMU) Specifications Output terminal/connection: Voltage Range, Resolution, and Accuracy (HRSMU) Dual triaxial connectors, Kelvin (remote sensing) Voltage Range ±2V ±20V ±40V ±100V 1 2 Set. Reso. 100µV 1mV 2mV 5mV Set. Accuracy ±(0.02%+400µV) ±(0.02%+3mV) ±(0.025%+6mV) ±(0.03%+15mV) Meas. Reso. 2µV 20µV 40µV 100µV Meas. Accuracy ±(0.01%+200µV) ±(0.01%+1mV) ±(0.015%+2mV) ±(0.02%+5mV) Max. Current 100mA 100mA 1 2 100mA (Vout £20V), 50mA (20V
Source Exif Data:File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2003:04:17 09:59:41 Producer : Acrobat Distiller 4.0 for Windows Creator : Windows NT 4.0 Title : 4156C_TO_Final421.pdf Modify Date : 2003:04:17 09:59:43-07:00 Page Count : 12EXIF Metadata provided by EXIF.tools