E5500 Phase Noise Measurement System Product Security A_70420 A 70420
User Manual: A_70420
Open the PDF directly: View PDF .
Page Count: 39
Download | ![]() |
Open PDF In Browser | View PDF |
E5500 Phase Noise Measurement System Product Security Agilent Technologies E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A Manufacturing Part Number: E5505-90008 Supersedes: July 2009 Printed in USA March 2012 © Copyright 2005 - 2012 Agilent Technologies, Inc. Notice The information contained in this document is subject to change without notice. Agilent Technologies makes no warranty of any kind with regard to this material, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. The following safety symbols are used throughout this manual. Familiarize yourself with the symbols and their meaning before operating this analyzer. WARNING Warning denotes a hazard. It calls attention to a procedure which, if not correctly performed or adhered to, could result in injury or loss of life. Do not proceed beyond a warning note until the indicated conditions are fully understood and met. CAUTION Caution denotes a hazard. It calls attention to a procedure that, if not correctly performed or adhered to, could result in damage to or destruction of the product. Do not proceed beyond a caution note until the indicated conditions are fully understood and met. NOTE Note calls out special information for the user’s attention. It provides operational information or additional instructions of which the user should be aware. Additional Information Documentation is updated periodically. For the latest information about this analyzer, including firmware upgrades, application information, and product information, see the following URL: http://www.agilent.com/find/ 2 Contents 1. E5500 Phase Noise Measurement System Product Security Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Contacting Agilent Sales and Service Offices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Product Declassification and Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Terms and Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A Phase Noise System Components . . . . . . . . . . . . 8 70420A, N5500A Test Set Instrument memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 70420A, N5500A memory clearing, sanitization and/or removal procedures . . . . . . . . . . . . . . . . . . . . . . 11 70420A Opt 001, N5500A Opt 001 Test Set Instrument memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 70420A Opt 001, N5500A Opt 001 memory clearing, sanitization and/or removal procedures . . . . . . . . . 14 70420A Opt 201, N5500A Opt 201 Test Set Instrument memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 70420A Opt 201, N5500A Opt 201 memory clearing, sanitization and/or removal procedures . . . . . . . . . 17 70421A, N5501A 6.6 GHz Downconverter Instrument memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 70421A, N5501A memory clearing, sanitization and/or removal procedures . . . . . . . . . . . . . . . . . . . . . . 20 70422A, N5502A 18 GHz Downconverter Instrument memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 70422A, N5502A memory clearing, sanitization and/or removal procedures . . . . . . . . . . . . . . . . . . . . . . 23 70427A, N5507A 26.5 GHz Downconverter Instrument memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 70427A, N5507A memory clearing, sanitization and/or removal procedures . . . . . . . . . . . . . . . . . . . . . . 26 70428A, N5508A 25.8 GHz Microwave Source Instrument memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 70428A, N5508A memory clearing, sanitization and/or removal procedures . . . . . . . . . . . . . . . . . . . . . . 29 70428A Opt 002, N5508A Opt 002 25.8 GHz Tunable Microwave Source Instrument memory . . . . . . . . 31 70428A Opt 002, N5508A Opt 002 memory clearing, sanitization and/or removal procedures . . . . . . . . . 32 E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A PC Controller (Kontron PC/Advantech PC IPC-610/Hewlett-Packard PC Vectra/Hewitt Rand PC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 User and remote interface security measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Appendix A: Other instruments that may be used with the E5500 Phase Noise System . . . . . . . . . . . . . . . 39 3 Contents 4 E5500 Phase Noise Measurement System Product Security 1 E5500 Phase Noise Measurement System Product Security Chapter 1 5 E5500 Phase Noise Measurement System Product Security Revision History Revision History Revision Modification A.01.00 Date 1/12/2005 A.02.00 Added 7042xA, E5501A/B, E5502A/B, E5503A/B, E5504A/B model numbers 6/22/2007 A.03.07 Added the new Kontron PC 7/15/2009 A.04.00 Added support for Window 7 3/9/2012 Contacting Agilent Sales and Service Offices Assistance with test and measurements needs and information on finding a local Agilent office is available on the internet at, http://www.agilent.com/find/assist. If you do not have access to the internet, please contact your field engineer. Note: In any correspondence or telephone conversation, refer to the E5501A/B, E5502A/B, E5503A/B, E5504A/B and E5505A phase noise system by its model number and full serial number. With this information, the Agilent representative can determine whether your unit is still within its warranty period. 6 Chapter 1 E5500 Phase Noise Measurement System Product Security Product Declassification and Security Product Declassification and Security System Model Number: E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A Product Name: Phase Noise Measurement System Product Family Name: E5500 Alternate Product Numbers: N/A This document describes E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A Phase Noise Measurement System security features and the steps to declassify the E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A through memory sanitization or removal. For additional information please go to www.agilent.com/find/ad and click on “Instrument Security”. Terms and Definitions Clearing – Clearing is the process of eradicating the data on media before reusing the media so that the data can no longer be retrieved using the standard interfaces on the instrument. Clearing is typically used when the instrument is to remain in an environment with an acceptable level of protection. Sanitization – Sanitization is the process of removing or eradicating stored data so that the data cannot be recovered using any known technology. Instrument sanitization is typically required when an instrument is moved from a secure to a non-secure environment such as when it is returned to the factory for calibration. (The instrument is declassified) Agilent memory sanitization procedures are designed for customers who need to meet the requirements specified by the US Defense Security Service (DSS). These requirements are outlined in the “Clearing and Sanitization Matrix” issued by the Cognizant Security Agency (CSA) and referenced in National Industrial Security Program Operating Manual (NISPOM) DoD 5220.22M ISL 01L-1 section 8-301. Security erase – Security erase is a term that is used to refer to either the clearing or sanitization features of Agilent instruments. Instrument declassification – A term that refers to procedures that must be undertaken before an instrument can be removed from a secure environment such as is the case when the instrument is returned for calibration. Declassification procedures will include memory sanitization and or memory removal. Agilent declassification procedures are designed to meet the requirements specified by the DSS NISPOM security document (DoD 5220.22M chapter 8) Chapter 1 7 E5500 Phase Noise Measurement System Product Security E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A Phase Noise System Components E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A Phase Noise System Components Product/System includes the following components Model number Name Description 70420A Test Set Standard configuration, 50 kHz to 1.6 GHz, 0 to 23 dBm 70420A/001 Test Set Adds 1.2 to 26.5 GHz, 0 to 30 dBm input and AM noise to standard configuration 70420A/201 Test Set Adds 1.2 to 26.5 GHz, 0 to 10 dBm input to standard configuration 70421A Downconverter Low noise 6.6 GHz downconverter 70422A Downconverter Low noise 18 GHz microwave downconverter 70427A Downconverter Low noise 26.5 GHz microwave downconverter 70428A Microwave Source Low noise 25.8 GHz microwave source 70428A/002 Microwave Source Low noise 25.8 GHz tunable microwave source N5500A Test Set Standard configuration, 50 kHz to 1.6 GHz, 0 to 23 dBm N5500A/001 Test Set Adds 1.2 to 26.5 GHz, 0 to 30 dBm input and AM noise to standard configuration N5500A/201 Test Set Adds 1.2 to 26.5 GHz, 0 to 10 dBm input to standard configuration N5501A Downconverter Low noise 6.6 GHz downconverter N5502A Downconverter Low noise 18 GHz microwave downconverter N5507A Downconverter Low noise 26.5 GHz microwave downconverter N5508A Microwave Source Low noise 25.8 GHz microwave source N5508A/002 Microwave Source Low noise 25.8 GHz tunable microwave source KISS-platform Kontron - PC E5505A Phase Noise System Controller IPC-610 Advantech - PC E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A Phase Noise System Controller Vectra Hewlett Packard E5501A/B, E5502A/B, E5503A/B, E5504A/B Phase Noise System Controller 8 Reference/ Remarks Chapter 1 E5500 Phase Noise Measurement System Product Security E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A Phase Noise System Components Hewitt Rand Chapter 1 E5501A/B, E5502A/B, E5503A/B, E5504A/B Phase Noise System Controller 9 E5500 Phase Noise Measurement System Product Security 70420A, N5500A Test Set Instrument memory 70420A, N5500A Test Set Instrument memory Writable During Normal Operation? Data Retained When Powered Off? Summary of instrument memory Memory Type and Size Purpose/ Contents Volatile Memory DRAM 128 KB Yes No Stores current measurement state for 70420A and N5500A test sets User Modifiable A6 PS/Controller board Cycle power Non-Volatile Memory No Yes Stores model #, serial #, options, calibration constants during calibration Non - User Modifiable A6 PS/Controller board Not required, no measurement data present No Yes Firmware for instrument operation Non - User Modifiable A6 PS/Controller board Not required, no measurement data present EEPROM 2 KB Non-Volatile Memory EPROM Data Input Method Location in Instrument and Remarks Sanitization Procedure 1 MB The 70420A and N5500A phase noise test sets do not store any measurement parameters while in the power off state. 10 Chapter 1 E5500 Phase Noise Measurement System Product Security 70420A, N5500A memory clearing, sanitization and/or removal procedures 70420A, N5500A memory clearing, sanitization and/or removal procedures DRAM (Volatile Memory) Description and purpose Stores current measurement state for the 70420A and N5500A test sets. Size 128 KB Memory clearing Cycle power Memory sanitization Cycle power Memory removal This memory cannot be removed without damaging the test set. Write protecting N/A Remarks: EEPROM (Non-Volatile Memory) Description and purpose Stores model #, serial #, options, calibration constants during calibration. Size 2 KB Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the test set. The 70420A and N5500A must be returned to Agilent for re-calibration. Write protecting N/A Remarks: Chapter 1 11 E5500 Phase Noise Measurement System Product Security 70420A, N5500A memory clearing, sanitization and/or removal procedures EPROM (Non-Volatile Memory) Description and purpose Firmware for instrument operation. Size 1 MB Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the test set. The 70420A and N5500A must be returned to Agilent for re-calibration. Write protecting N/A Remarks: NOTE: Cycling power or turning off the 70420A and N5500A sanitizes all instrument memory with the following exception: The EEPROM stores model #, serial #, options, and calibration constants generated during calibration. Measurement data is not stored in the EEPROM. 12 Chapter 1 E5500 Phase Noise Measurement System Product Security 70420A Opt 001, N5500A Opt 001 Test Set Instrument memory 70420A Opt 001, N5500A Opt 001 Test Set Instrument memory Writable During Normal Operation? Data Retained When Powered Off? Summary of instrument memory Memory Type and Size Purpose/ Contents Volatile Memory DRAM 128 KB Yes No Stores current measurement state for the 70420A/001 and N5500A/001 test sets User Modifiable A6 PS/Controller board Cycle power Non-Volatile Memory No Yes Stores model #, serial #, options, calibration constants during calibration Non - User Modifiable A6 PS/Controller board Not required, no measurement data present No Yes Firmware for instrument operation Non - User Modifiable A6 PS/Controller board Not required, no measurement data present EPROM Data Input Method Location in Instrument and Remarks Sanitization Procedure 2 KB Non-Volatile Memory EPROM 1 MB The 70420A/001 and N5500A/001 phase noise test sets do not store any measurement parameters while in the power off state. Chapter 1 13 E5500 Phase Noise Measurement System Product Security 70420A Opt 001, N5500A Opt 001 memory clearing, sanitization and/or removal procedures 70420A Opt 001, N5500A Opt 001 memory clearing, sanitization and/or removal procedures DRAM (Volatile Memory) Description and purpose Stores current measurement state for the 70420A/001 and N5500A/001 test sets. Size 128 KB Memory clearing Cycle power Memory sanitization Cycle power Memory removal This memory cannot be removed without damaging the test set. Write protecting N/A Remarks: EEPROM (Non-Volatile Memory) Description and purpose Stores model #, serial #, options, calibration constants during calibration. Size 2 KB Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the test set. The 70420A/001 and N5500A/001 must be returned to Agilent for re-calibration. Write protecting N/A Remarks: 14 Chapter 1 E5500 Phase Noise Measurement System Product Security 70420A Opt 001, N5500A Opt 001 memory clearing, sanitization and/or removal procedures EPROM (Non-Volatile Memory) Description and purpose Firmware for instrument operation. Size 1 MB Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the test set. The 70420A/001 and N5500A/001 must be returned to Agilent for re-calibration. Write protecting N/A Remarks: NOTE: Cycling power or turning off the 70420A/001 and N5500A/001 sanitizes all instrument memory with the following exception: The EEPROM stores model #, serial #, options, and calibration constants generated during calibration. Measurement data is not stored in the EEPROM. Chapter 1 15 E5500 Phase Noise Measurement System Product Security 70420A Opt 201, N5500A Opt 201 Test Set Instrument memory 70420A Opt 201, N5500A Opt 201 Test Set Instrument memory Writable During Normal Operation? Data Retained When Powered Off? Summary of instrument memory Memory Type and Size Purpose/ Contents Volatile Memory DRAM 128 KB Yes No Stores current measurement state for 70420A/201 and N5500A/201 test sets User Modifiable A6 PS/Controller board Cycle power Non-Volatile Memory No Yes Stores model #, serial #, options, calibration constants during calibration Non - User Modifiable A6 PS/Controller board Not required, no measurement data present No Yes Firmware for instrument operation Non - User Modifiable A6 PS/Controller board Not required, no measurement data present EEPROM Data Input Method Location in Instrument and Remarks Sanitization Procedure 2 KB Non-Volatile Memory EPROM 1 MB The 70420A option 001 and N5500A option 001 phase noise test sets do not store any measurement parameters while in the power off state. 16 Chapter 1 E5500 Phase Noise Measurement System Product Security 70420A Opt 201, N5500A Opt 201 memory clearing, sanitization and/or removal procedures 70420A Opt 201, N5500A Opt 201 memory clearing, sanitization and/or removal procedures DRAM (Volatile Memory) Description and purpose Stores current measurement state for the 70420A/201 and N5500A/201 test sets. Size 128 KB Memory clearing Cycle power Memory sanitization Cycle power Memory removal This memory cannot be removed without damaging the test set. Write protecting N/A Remarks: EEPROM (Non-Volatile Memory) Description and purpose Stores model #, serial #, options, calibration constants during calibration. Size 2 KB Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the test set. The 70420A/201 and N5500A/201 must be returned to Agilent for re-calibration. Write protecting N/A Remarks: Chapter 1 17 E5500 Phase Noise Measurement System Product Security 70420A Opt 201, N5500A Opt 201 memory clearing, sanitization and/or removal procedures EPROM (Non-Volatile Memory) Description and purpose Firmware for instrument operation. Size 1 MB Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the test set. The 70420A/201 and N5500A/201 must be returned to Agilent for re-calibration. Write protecting N/A Remarks: NOTE: Cycling power or turning off the 70420A/201 and N5500A/201 sanitizes all instrument memory with the following exception: The EEPROM stores model #, serial #, options, and calibration constants generated during calibration. Measurement data is not stored in the EEPROM. 18 Chapter 1 E5500 Phase Noise Measurement System Product Security 70421A, N5501A 6.6 GHz Downconverter Instrument memory 70421A, N5501A 6.6 GHz Downconverter Instrument memory Writable During Normal Operation? Data Retained When Powered Off? Summary of instrument memory Memory Type and Size Purpose/ Contents Volatile Memory DRAM 128 KB Yes No Stores current measurement state for the 70421A and N5501A downconverters User Modifiable A6 PS/Controller board Cycle power Non-Volatile Memory No Yes Stores model #, serial #, options, calibration constants during calibration Non - User Modifiable A6 PS/Controller board Not required, no measurement data present No Yes Firmware for instrument operation Non - User Modifiable A6 PS/Controller board Not required, no measurement data present EEPROM Data Input Method Location in Instrument and Remarks Sanitization Procedure 2 KB Non-Volatile Memory EPROM 1 MB The 70421A and N5501A phase noise downconverters do not store any measurement parameters while in the power off state. Chapter 1 19 E5500 Phase Noise Measurement System Product Security 70421A, N5501A memory clearing, sanitization and/or removal procedures 70421A, N5501A memory clearing, sanitization and/or removal procedures DRAM (Volatile Memory) Description and purpose Stores current measurement state for the 70421A and N5501A downconverters. Size 128 KB Memory clearing Cycle power Memory sanitization Cycle power Memory removal This memory cannot be removed without damaging the downconverter. Write protecting N/A Remarks: EEPROM (Non-Volatile Memory) Description and purpose Stores model #, serial #, options, calibration constants during calibration. Size 2 KB Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the downconverter. The 70421A and N5501A must be returned to Agilent for re-calibration. Write protecting N/A Remarks: EPROM (Non-Volatile Memory) Description and purpose Firmware for instrument operation. Size 1 MB 20 Chapter 1 E5500 Phase Noise Measurement System Product Security 70421A, N5501A memory clearing, sanitization and/or removal procedures Description and purpose Firmware for instrument operation. Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the downconverter. The 70421A and N5501A must be returned to Agilent for re-calibration. Write protecting N/A Remarks: NOTE: Cycling power or turning off the 70421A and N5501A sanitizes all instrument memory with the following exception: The EEPROM stores model #, serial #, options, and calibration constants generated during calibration. Measurement data is not stored in the EEPROM. Chapter 1 21 E5500 Phase Noise Measurement System Product Security 70422A, N5502A 18 GHz Downconverter Instrument memory 70422A, N5502A 18 GHz Downconverter Instrument memory Writable During Normal Operation? Data Retained When Powered Off? Summary of instrument memory Memory Type and Size Purpose/ Contents Volatile Memory DRAM 128 KB Yes No Stores current measurement state for the 70422A and N5502A downconverters User Modifiable A6 PS/Controller board Cycle power Non-Volatile Memory No Yes Stores model #, serial #, options, calibration constants during calibration Non - User Modifiable A6 PS/Controller board Not required, no measurement data present No Yes Firmware for instrument operation Non - User Modifiable A6 PS/Controller board Not required, no measurement data present EEPROM Data Input Method Location in Instrument and Remarks Sanitization Procedure 2 KB Non-Volatile Memory EPROM 1 MB The 70422A and N5502A phase noise downconverters do not store any measurement parameters while in the power off state. 22 Chapter 1 E5500 Phase Noise Measurement System Product Security 70422A, N5502A memory clearing, sanitization and/or removal procedures 70422A, N5502A memory clearing, sanitization and/or removal procedures DRAM (Volatile Memory) Description and purpose Stores current measurement state for the 70422A and N5502A downconverters. Size 128 KB Memory clearing Cycle power Memory sanitization Cycle power Memory removal This memory cannot be removed without damaging the downconverter. Write protecting N/A Remarks: EEPROM (Non-Volatile Memory) Description and purpose Stores model #, serial #, options, calibration constants during calibration. Size 2 KB Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the downconverter. The 70422A and N5502A must be returned to Agilent for re-calibration. Write protecting N/A Remarks: Chapter 1 23 E5500 Phase Noise Measurement System Product Security 70422A, N5502A memory clearing, sanitization and/or removal procedures EPROM (Non-Volatile Memory) Description and purpose Firmware for instrument operation. Size 1 MB Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the downconverter. The 70422A and N5502A must be returned to Agilent for re-calibration. Write protecting N/A Remarks: NOTE: Cycling power or turning off the 70422A and N5502A sanitizes all instrument memory with the following exception: The EEPROM stores model #, serial #, options, and calibration constants generated during calibration. Measurement data is not stored in the EEPROM. 24 Chapter 1 E5500 Phase Noise Measurement System Product Security 70427A, N5507A 26.5 GHz Downconverter Instrument memory 70427A, N5507A 26.5 GHz Downconverter Instrument memory Writable During Normal Operation? Data Retained When Powered Off? Summary of instrument memory Memory Type and Size Purpose/ Contents Volatile Memory DRAM 128 KB Yes No Stores current measurement state for the 70427A and N5507A downconverters User Modifiable A6 PS/Controller board Cycle power Non-Volatile Memory No Yes Stores model #, serial #, options, calibration constants during calibration Non - User Modifiable A6 PS/Controller board Not required, no measurement data present No Yes Firmware for instrument operation Non - User Modifiable A6 PS/Controller board Not required, no measurement data present EEPROM Data Input Method Location in Instrument and Remarks Sanitization Procedure 2 KB Non-Volatile Memory EPROM 1 MB The 70427A and N5507A phase noise downconverters do not store any measurement parameters while in the power off state. Chapter 1 25 E5500 Phase Noise Measurement System Product Security 70427A, N5507A memory clearing, sanitization and/or removal procedures 70427A, N5507A memory clearing, sanitization and/or removal procedures DRAM (Volatile Memory) Description and purpose Stores current measurement state for the 70427A and N5507A downconverters. Size 128 KB Memory clearing Cycle power Memory sanitization Cycle power Memory removal This memory cannot be removed without damaging the downconverter. Write protecting N/A Remarks: EEPROM (Non-Volatile Memory) Description and purpose Stores model #, serial #, options, calibration constants during calibration. Size 2 KB Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the downconverter. The 70427A and N5507A must be returned to Agilent for re-calibration. Write protecting N/A Remarks: 26 Chapter 1 E5500 Phase Noise Measurement System Product Security 70427A, N5507A memory clearing, sanitization and/or removal procedures EPROM (Non-Volatile Memory) Description and purpose Firmware for instrument operation. Size 1 MB Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the downconverter. The 70427A and N5507A must be returned to Agilent for re-calibration. Write protecting N/A Remarks: NOTE: Cycling power or turning off the 70427A and N5507A sanitizes all instrument memory with the following exception: The EEPROM stores model #, serial #, options, and calibration constants generated during calibration. Measurement data is not stored in the EEPROM. Chapter 1 27 E5500 Phase Noise Measurement System Product Security 70428A, N5508A 25.8 GHz Microwave Source Instrument memory 70428A, N5508A 25.8 GHz Microwave Source Instrument memory Writable During Normal Operation? Data Retained When Powered Off? Summary of instrument memory Memory Type and Size Purpose/ Contents Volatile Memory DRAM 128 KB Yes No Stores current measurement state for the 70428A and N5508A Mw Source User Modifiable A6 PS/Controller board Cycle power Non-Volatile Memory No Yes Stores model #, serial #, options, calibration constants during calibration Non - User Modifiable A6 PS/Controller board Not required, no measurement data present No Yes Firmware for instrument operation Non - User Modifiable A6 PS/Controller board Not required, no measurement data present EEPROM Data Input Method Location in Instrument and Remarks Sanitization Procedure 2 KB Non-Volatile Memory EPROM 1 MB The 70428A and N5508A phase noise microwave source does not store any measurement parameters while in the power off state. 28 Chapter 1 E5500 Phase Noise Measurement System Product Security 70428A, N5508A memory clearing, sanitization and/or removal procedures 70428A, N5508A memory clearing, sanitization and/or removal procedures DRAM (Volatile Memory) Description and purpose Stores current measurement state for the 70428A and N5508A microwave sources. Size 128 KB Memory clearing Cycle power Memory sanitization Cycle power Memory removal This memory cannot be removed without damaging the microwave source. Write protecting N/A Remarks: EEPROM (Non-Volatile Memory) Description and purpose Stores model #, serial #, options, calibration constants during calibration. Size 2 KB Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the microwave source. The 70428A and N5508A must be returned to Agilent for re-calibration. Write protecting N/A Remarks: Chapter 1 29 E5500 Phase Noise Measurement System Product Security 70428A, N5508A memory clearing, sanitization and/or removal procedures EPROM (Non-Volatile Memory) Description and purpose Firmware for instrument operation. Size 1 MB Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the microwave source. The 70428A and N5508A must be returned to Agilent for re-calibration. Write protecting N/A Remarks: NOTE: Cycling power or turning off the 70428A and N5508A sanitizes all instrument memory with the following exception: The EEPROM stores model #, serial #, options, and calibration constants generated during calibration. Measurement data is not stored in the EEPROM. 30 Chapter 1 E5500 Phase Noise Measurement System Product Security 70428A Opt 002, N5508A Opt 002 25.8 GHz Tunable Microwave Source Instrument memory 70428A Opt 002, N5508A Opt 002 25.8 GHz Tunable Microwave Source Instrument memory Volatile Memory DRAM 128 KB Non-Volatile Memory Purpose/ Contents Data Input Method Location in Instrument and Remarks Sanitization Procedure Data Retained When Powered Memory Type and Size Writable During Normal Operations? Summary of instrument memory Yes No Stores current measurement state for the 70428A/002 and N5508A/002 Mw Source User Modifiable A6 PS/Controller board Cycle power No Yes Stores model #, serial #, options, calibration constants during calibration Non - User Modifiable A6 PS/Controller board Not required, no measurement data present No Yes Firmware for instrument operation Non - User Modifiable A6 PS/Controller board Not required, no measurement data present EEPROM 2 KB Non-Volatile Memory EPROM 1 MB The 70428A/002 and N5508A/002 tunable microwave sources do not store any measurement parameters while in the power off state. Chapter 1 31 E5500 Phase Noise Measurement System Product Security 70428A Opt 002, N5508A Opt 002 memory clearing, sanitization and/or removal procedures 70428A Opt 002, N5508A Opt 002 memory clearing, sanitization and/or removal procedures DRAM (Volatile Memory) Description and purpose Stores current measurement state for the 70428A/002 and N5508A/002 microwave sources. Size 128 KB Memory clearing Cycle power Memory sanitization Cycle power Memory removal This memory cannot be removed without damaging the microwave source. Write protecting N/A Remarks: EEPROM (Non-Volatile Memory) Description and purpose Stores model #, serial #, options, calibration constants during calibration. Size 2 KB Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the microwave source. The 70428A/002 and N5508A/002 must be returned to Agilent for re-calibration. Write protecting N/A Remarks: EPROM (Non-Volatile Memory) Description and purpose Firmware for instrument operation. Size 1 MB 32 Chapter 1 E5500 Phase Noise Measurement System Product Security 70428A Opt 002, N5508A Opt 002 memory clearing, sanitization and/or removal procedures Description and purpose Firmware for instrument operation. Memory clearing Not required, no measurement data present Memory sanitization Not required, no measurement data present. Memory removal This memory cannot be removed without damaging the microwave source. The 70428A/002 and N5508A/002 must be returned to Agilent for re-calibration. Write protecting N/A Remarks: NOTE: Cycling power or turning off the 70428A/002 and N5508A/002 sanitizes all instrument memory with the following exception: The EEPROM stores model #, serial #, options, and calibration constants generated during calibration. Measurement data is not stored in the EEPROM. Chapter 1 33 E5500 Phase Noise Measurement System Product Security E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A PC Controller (Kontron PC/Advantech PC IPC-610/Hewlett-Packard PC Vectra/Hewitt Rand PC) E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A PC Controller (Kontron PC/Advantech PC IPC-610/Hewlett-Packard PC Vectra/Hewitt Rand PC) The Agilent E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A phase noise software stores user data and therefore the PC will need to be declassified following your normal PC declassification procedures. It is important to create a backup recovery DVD. The recovery DVD is the only way to reinstall the original Windows XP® operating system after replacing the hard drive. If a recovery DVD is not created, the only recourse is to purchase a brand new PC, available from Agilent as E5505AK08. The Kontron PC has a recovery partition for backup in case of hard drive failures. In case of a catastrophic hard drive failure, removable replacement drives are available for purchase. The E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A phase noise software stores user data in a measurements file (*.pnm). 34 Chapter 1 E5500 Phase Noise Measurement System Product Security E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A PC Controller (Kontron PC/Advantech PC IPC-610/Hewlett-Packard PC Vectra/Hewitt Rand PC) User and remote interface security measures Screen and annotation blanking (Frequency and Amplitude) CAUTION Implementing either of the “secured” levels described below is not reversible for that measurement file (*.pnm) only. Once the frequency or frequency/amplitude data has been blanked, it can not be recovered. If you need a permanent copy of the data, you can print out the graph and parameter summary before you secure the data and store the printed data in a secure location. An alternate method of storing classified data is to save the measurement file (*.pnm), including the real frequency/amplitude data onto a floppy disk or CD and secure the data. It can then be recalled at a later date. Security Level Procedure: 1. From the define menu, choose Security Level. 2. Choose one of the security options provided: • Unsecured: all data is viewable. • Secured: Frequencies cannot be viewed. • Secured: Frequencies and amplitudes cannot be viewed. Kontron PC and Advantech IPC-610 PC USB mass storage device security. Chapter 1 35 E5500 Phase Noise Measurement System Product Security E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A PC Controller (Kontron PC/Advantech PC IPC-610/Hewlett-Packard PC Vectra/Hewitt Rand PC) CAUTION Incorrectly editing the registry may severely damage your system. Before making changes to the registry, it is strongly recommended that you back up the registry and any valued data on the computer. To prevent USB write capability on Windows XP® SP2, create a new registry key of: HKLM\System\CurrentControlSet\Control\StorageDevicePolicies. Then create a REG_DWORD entry in it called WriteProtect. Set it to “1” and you'll be able to read from USB drives but not write to them. Remote access interfaces The user is responsible for providing security for the I/O ports for remote access by controlling physical access to the I/O ports. The I/O ports must be controlled because they provide access to all user settings and user states. The I/O ports include RS-232, GPIB and LAN. The LAN port provides the following services, which can be selectively disabled: http ftp sockets telnet There is also a ‘ping’ service, which presently cannot be selectively disabled. The concern here might be that it is possible to discover IP addresses of connected instruments in order to query their setups over the net or break into the code. 36 Chapter 1 E5500 Phase Noise Measurement System Product Security E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A PC Controller (Kontron PC/Advantech PC IPC-610/Hewlett-Packard PC Vectra/Hewitt Rand PC) Procedure for declassifying non-functioning instrument Model number Name 70420A Test Set 70420A/001 Test Set 70420A/201 Test Set 70421A Downconverter 70422A Downconverter 70427A Downconverter 70428A Microwave Source 70428A/002 Microwave Source N5500A Test Set N5500A/001 Test Set N5500A/201 Test Set N5501A Downconverter N5502A Downconverter N5507A Downconverter N5508A Microwave Source N5508A/002 Microwave Source KISS Platform Kontron PC Non-functioning Instrument Declassification Requirements Cycling power or turning off the instrument sanitizes all instrument memory with the following exception: The EEPROM stores model #, serial #, options, and calibration constants generated during calibration. Measurement data is not stored in the EEPROM. The Agilent E5505A phase noise software stores user data and therefore the PC will need to be declassified following your normal PC declassification procedures. The Kontron PC has a recovery partition on the hard drive to restore the factory default image to the C:drive. IPC-610 Advantech - PC Chapter 1 The Agilent E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A phase noise software stores user data and therefore the PC will need to be declassified following your normal PC declassification procedures. It is important to create a backup recovery DVD. The recovery DVD is the only way to reinstall the original Windows XP® operating system after replacing the hard drive. If a recovery DVD is not created, the only recourse is to purchase a brand new PC, available from Agilent as E5505AK08. 37 E5500 Phase Noise Measurement System Product Security E5501A/B, E5502A/B, E5503A/B, E5504A/B, E5505A PC Controller (Kontron PC/Advantech PC IPC-610/Hewlett-Packard PC Vectra/Hewitt Rand PC) Vectra Hewlett-Packard PC The Agilent E5501A/B, E5502A/B, E5503A/B, E5504A/B phase noise software stores user measurement data and therefore a non-functioning PC will need to be declassified following your normal PC declassification procedures. It is important to create a backup recovery DVD. The recovery DVD is the only way to reinstall the original Windows 2000® operating system after replacing the hard drive. If a recovery DVD is not created, the only recourse is to purchase a brand new PC, available from Agilent as E5505AK08. Hewitt Rand The Agilent E5501A/B, E5502A/B, E5503A/B, E5504A/B phase noise software stores user measurement data and therefore a non-functioning PC will need to be declassified following your normal PC declassification procedures. It is important to create a backup recovery DVD. The recovery DVD is the only way to reinstall the original Windows NT® operating system after replacing the hard drive. If a recovery DVD is not created, the only recourse is to purchase a brand new PC, available from Agilent as E5505AK08. 38 Chapter 1 E5500 Phase Noise Measurement System Product Security Appendix A: Other instruments that may be used with the E5500 Phase Noise System Appendix A: Other instruments that may be used with the E5500 Phase Noise System The E5500 phase noise system supports other instruments. For product security information specific to each instrument, refer to their individual product declassification and security documentation. Chapter 1 39
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c320 44.284297, Sun Apr 15 2007 17:19:00 Create Date : 2012:03:15 14:36:35Z Creator Tool : FrameMaker 8.0 Modify Date : 2012:03:16 07:52:57-07:00 Metadata Date : 2012:03:16 07:52:57-07:00 Producer : Acrobat Distiller 8.1.0 (Windows) Format : application/pdf Title : E5500 Phase Noise Measurement System Product Security Creator : Document ID : uuid:3160f564-cde0-41d2-99de-1555bca295ab Instance ID : uuid:f9146015-5ce5-4c18-9ae7-049e4aaf7450 Page Count : 39 Page Layout : SinglePage Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools