Agilent 87405A Preamplifier 10 MHz to 3 GHz Data Sheet Discontinued Product Information — For Support Reference Only — Information herein, may refer to products/services no longer supported. We regret any inconvenience caused by obsolete information. For the latest information on Agilent’s test and measurement products go to: www.agilent.com/find/products In the US, call Agilent Technologies at 1-800-829-4444 (any weekday between 8am–5pm in any U.S. time zone) World-wide Agilent sales office contact information is available at: www.agilent.com/find/contactus Features • • • • 24 dB Gain 6.5 dB Noise Figure Probe-Power Bias Connection Compact Size Benchtop/general purpose use Used alone on the bench, the Agilent Technologies 87405A can be added to any application in which additional gain and low noise are required. The compact and inexpensive 11899A probe power supply is a suitable source of DC bias in remote applications. The Agilent 87405A preamplifier brings reliable gain and low noise figure to measurement systems to improve overall system performance and reduce systematic errors. With its compact size and convenient probe-power bias connection, the 87405A is ideal for use as the front end preamplifier for a variety of Agilent instruments such as the 8590E series of portable spectrum analyzers. The 87405A is the recommended preamplifier for use with the 8594E Noise Figure Measurement Solution. The rugged design along with its insertable configuration of connectors makes the 87405A ideal for test port applications. Improve noise figure measurements Increase sensitivity and speed Add a preamplifier to noise figure measurement systems to significantly lower system noise figure. The noise figure of the system is dominated by the noise figure of the preamplifier. Adding preamplifiers to measurement systems can improve sensitivity for measuring low-level signals. Boost the sensitivity of your Agilent spectrum analyzer 15 to 25 dB by using the 87405A preamplifier. Alternatively, better sensitivity can be traded for measurement speed. Spurious tests often require narrow resolution bandwidths to reduce the noise floor of the analyzer, allowing low-level signal detection. An analyzer with low noise figure allows you to use a wider resolution bandwidth, yet achieve the same sensitivity. Sweeptimes can improve one hundred fold for each decade increase in bandwidth. The 87405A preamplifier has gain and noise figure characteristics that optimize dynamic range and sensitivity. Fnew = F pa + Fsys - 1 Gpa Where F and G are noise figure and preamplifier gain, both in linear terms. NFsys = 10 log (Fsys) in dB For systems having a single preamplifier, where the gain of the preamplifier is greater than or equal to the spectrum analyzer noise figure, the system noise figure approximately equals the noise figure of the preamplifier. Gain (dB) 28 12 11 27 10 26 9 25 8 24 7 23 6 5 22 4 21 0.01 3 0.5 1 1.5 Frequency (GHz) 2 2.5 3 2 2.5 3 Noise Figure (dB) 10 9 8 7 6 5 4 3 2 1 0.01 2 Output Power (dBm) @ 1 dB compression (dB) 0.5 1 1.5 Frequency (GHz) 0.01 0.5 1 1.5 Frequency (GHz) 2 2.5 3 87405A product specifications General specifications Frequency Range 10-3000 MHz Bias Voltage and Current 15 ±6% Vdc @ 80 mA nominal Small Signal Gain 22-27 dB min-max Connectors Gain Flatness ±1.25 dB 50-3000 MHz ±2.0 dB 10-3000 MHz Type N(f) in, N(m) out Probe Power Connector (f) Output Power (1 dBC) 4 dBm Noise Figure 6.5 dB 10-2000 MHz 7.5 dB 2000-3000 MHz RF DC Weight Third Order Intercept (TOI) 15 dBm typical Harmonics (@ +4 dBm output power) 20 dBc typical Input VSWR 1.5:1 10-1000 MHz 1.7:1 1000-2000 MHz 2.0:1 2000-2900 MHz 2.2:1 2900-3000 MHz Output VSWR 2.0:1 Impedance 50 ohms nominal Reverse Isolation 60 dB typical Survival Input Power (max) +13 dBm typical Power Dissipation 1.2 W nominal Temperature 0 to +55°C -40 to +70°C (operating) (storage) net 270 g, shipping 510 g Environmental information EMC IEC 801-2/1991 IEC 801-4/1988 IEC 801-3/1984 CISPR-11/1990 Moisture Resistance 65°C at 95% RH for 10 days per Mil-Std-883C method 1004.5 Random Vibration 5.2 G (rms) to 2000 Hz per Mil-Std883C method 2026-11A Shock 1500 G (peak), 0.5 ms per Mil-Std883C method 2002.3-B Altitude, non-operating 15,000 meters per Mil-Std-883C method 1001-C . Specifications describe the instrument’s warranted performance over the temperature range 0°C to +55°C (unless otherwise noted). All specifications apply after the instrument’s temperature has been stabilized after one hour continuous operation. Typical characteristics are intended to provide information useful in applying the instrument by giving typical but nonwarranted performance parameters. These are denoted as “typical” or “nominal” and apply over the temperature range 0°C to +55°C. Caution: Electrostatic Discharge (ESD) can damage or destroy electronic components. It is recommended that this preamplifier, like other electronic components, be installed and operated at a static-free workstation or in an environment where precautions against ESD have been implemented. 3 Ordering information www.agilent.com 87405A Preamplifier 10 MHz to 3 GHz 11899A Probe Power Supply (must order one option) Option 100 Option 120 Option 220 Option 240 100 V operation 120 V operation 220 V operation 240 V operation Related literature Pub. Number 8590E Series Technical Data Sheet 5091-3271E 11899A Technical Data Sheet 5091-0754E Noise Figure Measurement Accuracy Application Note 57-2 5952-3706 Agilent Technologies’ Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Two concepts underlie Agilent’s overall support policy: “Our Promise” and “Your Advantage.” Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you receive your new Agilent equipment, we can help verify that it works properly and help with initial product operation. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and onsite education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. 28.0 57.3 28.0 124.9 Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Open www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of systemready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development. United States: (tel) 800 829 4444 (fax) 800 829 4433 Canada: (tel) 877 894 4414 (fax) 800 746 4866 China: (tel) 800 810 0189 (fax) 800 820 2816 Europe: (tel) 31 20 547 2111 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Korea: (tel) (080) 769 0800 (fax) (080) 769 0900 Latin America: (tel) (305) 269 7500 Taiwan: (tel) 0800 047 866 (fax) 0800 286 331 Other Asia Pacific Countries: (tel) (65) 6375 8100 (fax) (65) 6755 0042 Email: tm_ap@agilent.com Contacts revised: 09/26/05 For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 1999, 2002, 2003, 2006 Printed in USA, July 11, 2006 5091-3661E
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Page Count : 4 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:da5dfe44-f2a6-4450-be8d-e285165a4252 Producer : Acrobat Distiller 6.0 (Windows) Create Date : 2006:07:26 09:32:37-07:00 Creator Tool : QuarkXPressª 4.1: PSPrinter 8.3.1 Modify Date : 2006:07:26 09:32:37-07:00 Document ID : uuid:5ae2c580-758e-4fba-890d-3e4edfc54e34 Format : application/pdf Title : 5091-3661E Creator : Elisa St. Marie Author : Elisa St. MarieEXIF Metadata provided by EXIF.tools