AA PBL0E TE_Guide_to_Installing_ULTRIX_Aug92 TE Guide To Installing ULTRIX Aug92
AA-PBL0E-TE_Guide_to_Installing_ULTRIX_Aug92 AA-PBL0E-TE_Guide_to_Installing_ULTRIX_Aug92
User Manual: AA-PBL0E-TE_Guide_to_Installing_ULTRIX_Aug92
Open the PDF directly: View PDF .
Page Count: 153
Download | |
Open PDF In Browser | View PDF |
ULTRIX Guide to Installing ULTRIX Part Number: AA-PBLOE-TE ULTRIX Guide to Installing ULTRIX Order Number: AA-PBLOE-TE August 1992 Product Version: ULTRIX and ULTRIX Worksystem Software, Version 4.3 This guide describes the basic and advanced installation procedures for ULTRIX and ULTRIX Worksystem Software on all supported processors. This guide also describes how to upgrade a system without having to perform an installation. digital equipment corporation Maynard, Massachusetts Restricted Rights: Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth in subparagraph (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013. © Digital Equipment Corporation 1987, 1988, 1989, 1990, 1992 All rights reserved. The information in this document is subject to change without notice and should not be construed as a commitment by Digital Equipment Corporation. Digital Equipment Corporation assumes no responsibility for any errors that may appear in this document. The software described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license. No responsibility is assumed for the use or reliability of software on equipment that is not supplied by Digital or its affiliated companies. The following are trademarks of Digital Equipment Corporation: ALL-IN-I, Bookreader, CDA, DDIF, DDIS, DEC, DEC FUSE, DEC net, DEC station, DEC system, DECUS, DECwindows, DTIF, MASSBUS, MicroVAX, Q-bus, ULTRIX, ULTRIX Mail Connection, ULTRIX Worksystem Software, UNIBUS, VAX, VAXstation, VMS, VT, XUI, and the DIGITAL logo. Ethernet is a registered trademark of Xerox Corporation. IBM is a registered trademark of International Business Machines Corporation. INGRES is a trademark of Ingres Corporation. Prestoserve is a trademark of Legato Systems, Inc.; the trademark and software are licensed to Digital Equipment Corporation by Legato Systems, Inc. Modula-2 is a trademark of Interface Technologies Corporation. PostScript and Display PostScript are registered trademarks of Adobe Systems, Inc. UNIX is a registered trademark of UNIX System Laboratories, Inc. Contents About This Manual ix Audience Organization . .. . . . . .. . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . Related Documentation ............. ......................................................................... Conventions 1 1.1 ix x x Preparing for the Installation Deciding on the Type of Installation 1.1.1 1.1.2 1.1.3 1.1.4 The The The The ........................................................... 1-1 Upgrade Installation ................................................................. Basic Installation ..................................................................... Advanced Installation ............................................................... System Management Option ..................................................... 1-2 1-2 1-3 1-4 1.2 Checking the Hardware Needed for Installation 1-4 1.3 Checking the Software Distribution Kit ....................................................... 1-5 1.4 Backing Up the System ............................................................................. 1-6 Backups Before Upgrades ............................................................... Backups Before Basic and Advanced Installations ................ .............. The Next Step ............................................................................... 1-6 1-6 1-7 1.4.1 1.4.2 1.4.3 2 Planning Your Disk Space 2.1 Identifying Supported System Disks 2-2 2.2 Planning the Swap Space 2-4 2.3 Planning the Crash Dump Space 2-5 2.4 Planning the var Area .............................................................................. . 2-6 Size of the var/adm/crash Directory ................................................. . Error Logger ................................................................................ . System Accounting ....................................................................... . 2-7 2-7 2-7 2.4.1 2.4.2 2.4.3 2.4.4 2.4.5 2.5 Size of the var/admlris Directory .................................................... . Completing the var Worksheet ........................................................ . Planning the lusr File System 2.5.1 2.5.2 2.5.3 2.5.4 2-8 2-8 2-9 Software Subsets Within the lusr File System .................................. .. User Area .................................................................................... . var Area ...................................................................................... . Completing the lusr Worksheet ....................................................... . 2-9 2-9 2-10 2-10 2.6 Determining the Disk Partition Layout 2-10 2.7 Planning the Configuration File Entries 2-11 3 3.1 Booting the System DEC station 2100/3100/3100S or DECsystem 3100 Processor ......................... 3-4 Booting from the TK50 Tape Cartridge Kit ....................................... Booting from the CDROM Optical Disc Kit ...................................... Booting from the Network .............................................................. 3-4 3-4 3-5 DEC station 5000 Series, DEC system 5000 Series, Personal DEC station 5000 Series, and the DECsystem 5900 Processor ............................................. 3-6 3.2.1 3-6 3.1.1 3.1.2 3.1.3 3.2 Determining the Slot and Device Numbers of Your Boot Device Determining the Slot Number (Default) ................................ .. Determining the Boot Device Number ................................... . 3--6 Booting from the TK50 Tape Cartridge Kit ..................................... .. Booting from the CDROM Optical Disc Kit ..................................... . Booting from the Network ............................................................. . 3-7 3-7 3.2.1.1 3.2.1.2 3.2.2 3.2.3 3.2.4 3.3 DECsystem 5100 Processor 3.3.1 3.3.2 3.3.3 3-7 3-8 ....................................................................... 3-9 Booting from the TK50 Tape Cartridge Kit ....................................... Booting from the CDROM Optical Disc Kit ...................................... Booting from the Network .............................................................. 3-9 3-9 3-10 3.4 DEC system 5400 Processor 3-11 3.5 DEC system 5500 Processor 3-12 Booting from Booting from Booting from Booting from 3-12 3-13 3-13 3-13 3.5.1 3.5.2 3.5.3 3.5.4 the the the the SCSI Tape Device ............................................... . Q-bus Tape Device ............................................. .. CDROM Optical Disc Kit ..................................... . Network ............................................................. . 3.6 DEC system 5810/5820/5830/5840 Processor 3.7 MicroVAX 2000, VAXserver 2000, or VAXstation 2000 Processor 3.7.1 ivContents Booting from the TK50 Tape Cartridge Kit 3-15 ................ 3-17 ....................................... 3-17 3.7.2 3.8 3.10 ................ 3-19 Booting from the TK50 Tape Cartridge Kit ...................................... . Booting from the CDROM Optical Disc Kit ..................................... . Booting from the Network ............................................................. . 3-19 3-20 3-21 MicroV AX 3300/3400 or V AXserver 3300/3400 Processor 3-22 3.9.1 3.9.2 Booting from the TK50 Tape Cartridge Kit ...................................... . Booting from the Network ............................................................ .. 3-22 3-22 MicroV AX II, MicroV AX 3500/3600/3800/3900, V AXserver 100/3500/3600/3800/3900, VAXstation 3200/3500, VAXstation II, or VAX station IIIGPX Processor .............................................................. . 3-24 3.10.1 3.10.2 3.11 3-18 MicroVAX 3100, VAX server 3100, or VAX station 3100 Processor 3.8.1 3.8.2 3.8.3 3.9 Booting from the Network Booting from the TK50 Tape Cartridge Kit ................................... .. Booting from the Network ........................................................... . V AXstation 3520 or V AXstation 3540 Processor 3.11.1 3.11.2 3.11.3 3-24 3-25 ....................................... . 3-26 Booting from the TK50 Tape Cartridge Kit .................................... . Booting from the CDROM Optical Disc Kit .................................. .. Booting from the Network ........................................................... . 3-26 3-27 3-27 3.12 VAX-ll/750 Processor 3.13 V AX-11/780 or V AX-11/785 Processor 3-30 3.14 VAX 6000-nnn Series or VAX server 6000-nnn Series Processor 3-32 3.14.1 3.14.2 3.14.3 ........................................................................... Booting from the TK50 Tape Cartridge Kit .................................... . Booting from a System with a CIBCA-AA Controller ...................... . Booting from a System with a CIBCA-AB Controller ...................... . 3.15 V AX 8200/8250 or V AX 8300/8350 Processor 3.16 VAX 8500/8530/8550, VAX 8700, or VAX 8800/8810 Processor 3.17 V AX 8600/8650 Processor 3.18 V AX 8820/8830/8840 Processor 3.18.1 3.18.2 3.19 4 ......................................... . ............... . 3-28 3-32 3-32 3-33 3-34 3-36 3-37 .............................................................. . 3-38 Booting Sequence for a System Disk Connected to a Local Controller. Booting Sequence for a System Disk Connected to an HSC ............... 3-38 3-39 V AX 9000 Processor 3-40 Performing the Installation 4.1 Choosing the Type of Installation 4-1 4.2 Selecting the Software Distribution Device 4-2 Contents v 4.3 Selecting the Disk for the root Partition 4.4 Rebooting the System 4.5 Specifying System Information 4.6 Allocating File Systems 4.6.1 4.6.2 4.6.3 4.6.4 4.6.5 Allocating Allocating Allocating Allocating Allocating ...................................................... 4-3 ............................................................................... 4-5 .................................................................. 4-5 ............................................................................ 4-6 the lusr File System ....................................................... . the swap 1 Space ............................................................ . the swap2 Space ............................................................ . the Crash Dump Space ................................................... . the var Area .................................................................. . 4-7 4-8 4-9 4-10 4-11 4.7 Installing ULTRIX Worksystem Software 4-12 4.8 Loading the Software Subsets .................................................................... 4-13 Installing from TK50 or MT9 Tape .................................................. Installing from a CDROM .............................................................. Loading Software Subsets for the Basic Installation ........................... Loading Software Subsets for the Advanced Installation ..................... 4-13 4-14 4-14 4-14 4.8.1 4.8.2 4.8.3 4.8.4 4.9 Loading the Software Subset Upgrades 4-16 4.9.1 4.9.2 4-16 4-17 Loading Upgrades from TK50 or MT9 Tape .................................... . Loading Upgrades from CDROM ................................................... . 4.10 Specifying Kernel Options for the Configuration File 4-18 4.11 Console Boot Defaults and Console Media 4-20 4.11.1 4.11.2 Updating the Console Boot Default ............................................... . Updating the Console Media ........................................................ . 4-21 4-21 4.12 _Completing the Installation and Rebooting the System 4-22 4.13 4-23 Post-Installation Procedures 5 Performing an Upgrade 5.1 Upgrading A Local System 5.1.1 5.1.2 5.1.3 5.1.4 5.1.5 5.1.6 ....... ................................................................. 5-2 Starting the Upgrade ..... ................................................................. Upgrading from a TK50 or MT9 ...................................................... Upgrading from a CDROM ............................................................. Upgrading from the Network .... ..... .... ........ ............ ...... .... ................ Loading the Software Subsets .......................................................... Loading the Software Subset Updates ............................................... 5-2 5-3 5-3 5-3 5-3 5-4 5.1.6.1 5.1.6.2 5.1.6.3 5.1.7 vi Contents Updating from a TK50 or MT9 ............................................. Updating from CDROM ....................................................... Updating from the Network .................................................. Rebuilding a Kernel when the Required Kernel Is Available ................ 5-4 5-5 5-5 5-6 5.1.8 5.2 Upgrading a Remote Installation Services Area 5.3 Upgrading a Diskless Management System Area 6 Listing Software Subsets 6.2 Adding Subsets 6.2.1 6.2.2 7 ........................................................................... 6-1 ........................................................................................ 6-1 Adding Subsets from Tape .............................................................. Adding Subsets from a File Server ................................................... 6-2 6-2 Deleting Subsets 6-2 Working in the Standalone ULTRIX Environment 7.1 7.2 Invoking the Standalone ULTRIX Environment 7.3 Extending the Standalone ULTRIX Environment A RiSe Supported Software Subsets B VAX Supported Software Subsets C Unsupported Software Subsets D Sample Advanced Installation Procedure D.1 5-9 5-9 Adding and Deleting Software Subsets 6.1 6.3 5-7 Rebuilding a Kernel when the Required Kernel Is Not Available 7-1 7-2 7-2 Standalone ULTRIX Environment Capabilities Sample Advanced Installation Procedure. D-1 Index Tables 1-1: Names of Directories and Files to Back Up 2-1: Supported System Disks .................................................. . ............................................................................ . 2-2: Disk Configuration Worksheet ................................................................... . 1-7 2-2 2-3 2-3: Partial Crash Dump Space Requirements 2-6 2-4: var Worksheet 2-8 .......................................................................................... . Contents vii 2-5: lusr Worksheet 2-10 2-6: File System Worksheet 2-11 2-7: Configuration File Entries ..... , ., ....... , . . . . .. . . . . . . . .. . ... . . . .. . . . .. . .. . . .. . . . . . . .. . . . . .. . .. . . . . .. 3-1: Location of Processor-Specific Boot Instructions 4-1: Post-Installation Tasks ........................................... 3-1 ............................................... ................................ 4-23 A-I: RISC Supported Subset Descriptions and Dependencies ................................. B-1 : VAX Supported Software Subset Descriptions and Dependencies C-l: Unsupported Software Subset Descriptions and Dependencies viii Contents 2-12 .................... A-I B-1 C-l About This Manual This guide describes the basic and advanced installation procedures for ULTRIX and ULTRIX Worksystem Software (UWS) on all supported processors. It describes how to prepare your system for installation, boot the processor, and perform the installation procedure. In addition, this guide discusses: • An upgrade procedure for certain systems, which you use instead of the basic or advanced installation procedures to produce the new version of the product. The upgrade procedure can be run on all ULTRIX and UWS Version 4.2 or higher systems. • Standalone system management procedures, which operate in a memory-resident environment to support limited system management activities. Audience The audience for this guide is anyone installing an ULTRIX system. The guide assumes that: • You or a Digital Field Service representative has checked the hardware to ensure that it is working properly. • You have read the documentation supplied with your hardware. • You have read the current version of the Release Noles. • You know the location and function of the controls and indicators on your hardware. • You understand how to load and unload the installation media and know which disks are needed during the installation. • You have a basic understanding of the ULTRIX file system and commands. Organization This guide has seven chapters, four appendixes, and an index: Chapter 1 Describes the basic and advanced installation procedures and outlines the tasks you must complete before beginning an installation. Chapter 2 Describes the tasks you should complete before beginning an advanced installation. This chapter contains a set of worksheets to help you plan your system. Chapter 3 Describes how to boot each processor that can support the ULTRIX software. Chapter 4 Describes how to complete the basic and advanced installations. Chapter 5 Describes how to perform an upgrade procedure. Chapter 6 Describes how to use the set 1 d utility to add or delete subsets after the installation is complete. Chapter 7 Describes a memory-resident environment that supports the initial phases of an installation and limited system management activities. Appendix A Describes each supported subset for RISC processors and lists any related subsets and system configuration file options. Appendix B Describes each supported subset for VAX processors and lists any related subsets and system configuration file options. Appendix C Describes each unsupported subset for RISC and VAX processors. Appendix D Provides a complete example of an advanced installation. Related Documentation The following list suggests the order in which you should read the related documentation: 1. Hardware documentation This documentation shows you how to set up the processor and its additional devices, and supplies valuable troubleshooting guidelines. 2. Release Notes This document contains media labelling, subset sizes, and other installationrelated notes. Please read the release notes before beginning the installation or update procedures. 3. Guide to System and Network Setup You should refer to this guide to help you determine what to do after you complete the advanced installation. 4. Guide to Sharing Software on a Local Area Network This documentation describes how to install software products over the network. Conventions # A number sign represents the superuser prompt. % cat Boldface type in interactive examples indicates typed user input. file Italic (slanted) type indicates variable values, placeholders, and function argument names. In syntax definitions, a horizontal ellipsis indicates that the preceding item can be repeated one or more times. cat(l) x About This Manual A cross-reference to a reference page includes the appropriate section number in parentheses. For example, cat(l) indicates that you can find information on the cat command in Section 1 of the reference pages. Ctrl/x This symbol indicates that you hold down the first named key while pressing the key or mouse button that follows the slash. In examples, this key combination is enclosed in a box (for example, ICtri/C I). About This Manual xi Preparing for the Installation 1 This chapter describes the basic and advanced installation procedures and discusses the tasks you must complete before beginning the installation. Before you begin the installation, do the following: • Read the Release Notes The Release Notes contain information about installing and upgrading the software, including hardware, boot, and general installation notes, such as outstanding problems and their workarounds. The Release Notes also contain the subset sizes for the RISC, VAX, and unsupported software. You will use these subset sizes to help determine the characteristics of the system(s) you will install. • Decide whether you must use the upgrade procedure for your installation Chapter 5 contains a procedure that allows you to upgrade to the current version of ULTRIX and UWS without performing a basic or advanced installation. The upgrade procedure is only for systems running ULTRIX and UWS Version 4.2 or higher. • Decide whether to perform a basic or advanced installation For new installations and for systems running ULTRIX and UWS versions earlier than Version 4.2, Chapter 2 contains a set of worksheets designed to help you plan your system. Working through Chapter 2 before beginning the advanced installation will help you determine if you have enough disk space on your system. 1.1 • Check to be sure you have the hardware needed for installation • Check the contents of the software distribution kit against the Bill of Materials • Back up the system if you need to retain any information from your previous system Deciding on the Type of Installation ULTRIX software can be installed on your system in the following ways: • If your system comes with Factory Installed Software (FIS), all of the ULTRIX supported software subsets are installed at the factory. If you have PIS, you do not need this guide. Refer to the PIS documentation included with your processor. • From TK50 tape cartridges. • From an RRD40 or RRD42 CDROM optical disc cartridge. • From MT9 magnetic tapes. • From the network. A Remote Installation Services (RIS) client uses the network to install software from a server that has been established with RIS. The installation procedure provides four paths for you to follow: the upgrade installation, the basic installation, the advanced installation, or the system managment option. In addition, the installation procedure provides the system management option. 1.1.1 The Upgrade Installation The upgrade installation allows you to preserve your current ULTRIX and UWS environment while upgrading to the new system. You do not have to perform a basic or advanced installation and you do not have to save and restore your customizable system files. The upgrade procedure saves all your customizable system files before it copies and verifies the subsets from the distribution medium. Then, the upgrade is applied to your current system. Finally, you rebuild your system's kernel to effect the upgrade to the new system version. There is one restriction: any customizable files which you have modified and are from the unsupported subsets will be replaced when the unsupported subsets are installed. The procedure does not save the customizable files in any unsupported subset. See Chapter 5 for more information. 1.1.2 The Basic Installation The basic installation installs a default system with a minimum of prompts. The basic installation procedure creates file systems on default partitions on your system disk and loads the required software subsets. You should choose this path if you are new to the ULTRIX operating system or if you want to install a basic system. There are some post-installation procedures that you will not perform if you choose the basic installation. For example, printer services are not available with the basic installation. See Table 4-1 for further information. The basic installation creates the following areas on default partitions on the system disk: • The root file system • The /usr file system • The crash dump space and the swap space The var area is created as a directory under the /usr file system. The basic installation loads the following required supported software subsets: • Base System • Kernel Configuration Files • TCPIIP Networking Utilities • Network File System Utilities • Extended (Berkeley) Mailer If your system is licensed to install ULTRIX Worksystem Software, the following supported software subsets are also loaded during the basic installation: 1-2 Preparing for the Installation • XIIIDECwindows Servers • XIl1DECwindows User Environment • XIl1DECwindows 75dpi Fonts The basic installation performs the following tasks: • Builds the kernel • Reboots the ULTRIX operating system If after completing the installation you decide that you want additional subsets, you can install these subsets using the setld utility. See the setld(8) reference page for further information. 1.1.3 The Advanced Installation If you choose the advanced installation you can select the default disk partitions and the default file system layout, or you can decide on which disks you want the file systems to reside. The advanced installation also lets you select and install some or all of the optional subsets. You should choose this path only if you are experienced with ULTRIX file systems or if you require the ability to perform tasks such as the following: • Preserving customized partitions • Selecting file system layouts other than the default layouts • Allocating the /usr file system to any disk partition on your system • Allocating up to two swap areas to any disk partition on your system • Allocating the crash dump space to the same disk partition as one of the swap areas or allocating it to a different disk partition • Allocating the var area to the same disk partition as /usr or allocating it to a different disk partition • Selecting optional subsets • Adding options to the kernel configuration file Performing these tasks during the advanced installation has the following advantages: • It allows for greater flexibility in allocating the file systems to the most appropriate disk partition. • It lets you tailor the ULTRIX operating system to suit the needs of your site. For example, if your system has multiple disks, you may want to place some of the mandatory file systems on disks other than the system disk. This may improve your system's performance. Before you begin an advanced installation, you must know the size and location of the areas you are going to allocate and which subsets you are going to select. Chapter 2 contains a set of worksheets to help you plan your system. Fill out these worksheets before you begin an advanced installation. Preparing for the Installation 1-3 Note Advanced installations are required for VAXstation 3520 and 3540 systems. 1.1.4 The System Management Option The system management option creates a standalone ULTRIX environment. The standalone environment supports the initial phases of an installation as well as limited system management activities. The standalone ULTRIX environment includes commands that assist in recovering from root file system corruption and help perform general file system and disk maintenance tasks. You should perform system management tasks in the standalone ULTRIX environment only if you have extensive ULTRIX or UNIX operating system experience. 1.2 Checking the Hardware Needed for Installation To perform the installation you need to understand how to operate your system. The documentation provided with your processor provides operating and troubleshooting instructions. You may also need some or all of the following hardware: • Software distribution device You need a distribution device that corresponds with the software distribution media. For example, if you have a TK50 software kit, you need a TK50 or TK70 tape drive. Load the media supplied with the software distribution kit on the appropriate drive. See your hardware documentation for instructions on how to load media. If you are installing from a RIS area, see your server administrator for instructions. • System disk The system disk is the disk from which you will boot your system. You should know how to load a disk pack (if it is removable) on your disk drive. You should also know how to get the disk ready for read/write operations. See your hardware documentation for information. • Data disks A data disk is a device on which you can store data files. In most cases, you do not need any data disks to install the ULTRIX system. However, if you perform an advanced installation, you can allocate certain file systems to a disk other than the system disk. If you are going to perform an advanced installation and are going to use data disks, back up any data on the disks before you begin. • Console terminal You use the console terminal to communicate with your system during the installation. Depending on your system and its configuration, you can perform the installation at either a hardcopy or a video terminal. The rest of this section does not apply to the following processors: • DEC station 2100/3100/3100S 1-4 Preparing for the Installation • .DECstation 5000, Model 100 and 200 series • Personal DEC station 5000, Model 20 and 25 • DECsystem 3100 • DECsystem 5000, Model 25 • DECsystem 5000, Model 200 series • DECsystem 5810/5820 • DECsystem 5900 • Micro VAX 2000, VAX server 2000, VAXstation 2000 • MicroVAX 3100, VAXserver 3100, VAXstation 3100 Check with a Digital Field Service representative to ensure that your hardware is installed at the default control status register (CSR) addresses. If you have hardware installed in the floating address space and it does not adhere to the standard algorithm for address assignments, you should perform an advanced installation. The advanced installation lets you modify these address assignments in the system configuration file. After you modify these address assignments, the installation software should successfully build the kernel. To perform an advanced installation, you should understand the format of the system configuration file and know how to use the ed editor. If you do not, then you should have a Digital Field Service representative install your hardware at the standard CSR addresses before you start the installation. See the Guide to Configuration File Maintenance for information about the configuration file. Note For UNIBUS and Q-bus controllers, the ULTRIX operating system must be installed on a system disk connected to a disk controller set at the primary CSR address. If you have a disk controller at a secondary CSR address, have a Digital Field Service representative switch the CSR address so that the system disk is connected to the primary CSR. 1.3 Checking the Software Distribution Kit Use the Bill of Materials to check your software distribution kit. The software distribution kit includes this installation guide and one of the following: • A TK50 for systems with TK50 or TK70 tape cartridge drives • A CDROM optical disc kit for systems with RRD40 or RRD42 optical disc drives • A MT9 magnetic tape kit for systems with magnetic tape drives Systems that use a software distribution kit supplied by a remote server require the use of the network. If you plan to install software over the local area network, find out from your system administrator whether the network kit is set up and ready for use. Preparing for the Installation 1-5 1.4 Backing Up the System Whether you perform an upgrade or an installation, you should back up your system before starting the procedure. 1.4.1 Backups Before Upgrades Before you begin an upgrade procedure, you should back up your system disk so you can restore your system to known state should any errors occur during the upgrade procedure. 1.4.2 Backups Before Basic and Advanced Installations When you perform a basic or an advanced installation, the installation software initializes the system disk, overwrites all files and data residing on the system disk, and may overwrite any changes to disk partition sizes you made using the chpt command. The installation software does not overwrite partition size changes you have made on data disks. If you are currently running an operating system, back up your system disk before beginning the installation. The backup procedure is described in the Guide to Backup and Restore. If you plan to perform the advanced installation, you should also back up any data disks you plan to use. Before you begin the installation, you may want to save certain files to retain information specific to your site. Some files are not meant to be restored after the installation, for example the get tytab file. Other files, for example your existing hosts file, can be restored so that you do not need to retype them. Table 1-1 lists the directory name and the file name for the files that you may want to back up. 1-6 Preparing for the Installation Table 1-1: Names of Directories and Files to Back Up Directory File / .cshrc .profile .login .rhosts .mailrc /etc acucap aliases.pag dumpdates gettytab hosts.equiv phones remote sendmail.fc services termcap aliases automount.master exports group passwd printcap resolv.conf sendmail.hf svc.conf ttys aliases.dir crontab fstab hosts /usr/var/adrn aculog lastlog lpd-errs /usr/var/uucp L.cmds LIST.NIGHT uucp.longhall uucp.week LIST.DAY LIST.NOON uucp.night USERFILE LIST.HOUR uucp.hour uucp.noon rc.local sendrnail.cf sendrnail.st svcorder You may also want to save the syslog file from the /usr/var/spool/mqueue directory. In addition to your site-specific files, you need to save the following: • If your system runs as a master or a slave Yellow Pages (YP) server, save the /usr /var /yp/ domain-name directory for your domain. • If your system runs as the master YP server and the master copies of the files used to create the YP maps are located in a separate directory, such as /usr /var /yp/ src, save this directory as well. • If your system runs as a BINDlHesiod primary server, save the named. boot file in the /usr /var / dss /narnedb default directory, all database files named in the named. boot file, and the /usr /var / dss /narnedb/ src directory, where the source files are located. Database files have . db extensions, source files have . rev extensions. 1.4.3 The Next Step If you are performing an upgrade, continue the procedure with Chapter 5. If you are performing a basic installation, continue the installation procedure with Chapter 3. If you are performing an advanced installation, continue the installation procedure with Chapter 2. If you are performing system management tasks, continue with Chapter 7. Preparing for the Installation 1-7 Planning Your Disk Space 2 You need to complete the following tasks before starting the advanced installation: • Identify available disks • Plan the swap space • Plan the crash dump space • Plan the var area • Plan the / u s r file system • Plan the kernel configuration file items • Decide whether to use the default disk partition layout or the existing disk partition layout if you have modified the default disk partitions, and change the partition layout if necessary This chapter provides a summary of what you need to consider before determining which disk partition is suitable for the file systems, swap space, and crash dump space. It assumes that you know the contents of the file systems and understand the concepts associated with allocating a file system to a disk partition. If you are unsure of these concepts, see the following guides for more detailed conceptual information: • Guide to Disk Maintenance • Guide to System Crash Recovery • Guide to Configuration File Maintenance In several sections of this chapter, you will need to complete worksheets that pertain to the size of the file system being discussed. Many of the ULTRIX commands that you may use before and after the installation give disk space size in different units. For example, the chpt command gives the size of partitions in blocks or sectors. However, the df command measures the space in kilobytes. The subset sizes are also given in kilobytes. To aid you in determining disk space requirements, keep in mind the following equations: • One kilobyte (KB) equals 1024 bytes. • One block equals 1/2 KB (512 bytes); a sector is the same as a block. • One megabyte (MB) equals 1024 KB (1,048,576 bytes), or 2048 blocks. For example, to determine the size in MB of the default disk partitions for an RA70 disk, divide the length in blocks (as shown in ra(4)) or the size in blocks (as displayed by the chpt command) by 2048: Partition Size in Blocks Size in MB a 32768 16 b 131072 64 c 547041 267 d 163840 80 e 471041 230 f 76001 37 g 383201 187 When you examine disk partitions with the chpt command or look in the ULTRIX Reference Pages you are looking at the partitions as if they were unformatted. To account for the ULTRIX file system when determining the size your disk partitions need to be, subtract 16 percent of the size of the partition to give you the total available space. The information presented in Section 2.1 through Section 2.5 will enable you to complete the summary worksheet in Section 2.6. When complete, this worksheet will give you the complete layout of the file systems that you will be asked about during the advanced installation. 2.1 Identifying Supported System Disks Your system disk must be a supported bootable device. Table 2-1 lists possible system disks and their associated ULTRIX mnemonics. If you are installing a system for the first time, you will need to refer to the reference page for your system disk in Section 4 of the ULTRIX Reference Pages for information on the default disk partition layout. Table 2-1: Supported System Disks ULTRIX Mnemonic Device Name hp RM05 ra RA60, RA70, RA80, RA81, RA82, RA90, RA92, RD53, RD54, RF30, RF31, RF71 rd RD53 (MicroV AX 2000 and VAXstation 2000 only), RD54 (MicroVAX 2000 and VAXstation 2000 only) rz RZ23, RZ23L, RZ24, RZ25, RZ55, RZ56, RZ57 Note RD53, RZ23, and RZ23L disks are not supported as single-system disks. You will need a second suitably sized disk to perform the installation. 2-2 Planning Your Disk Space The system disk contains the root file system and the swap 1 space. The unit number for the system disk must be in the range 0 to 254 for ra-type devices or in the range 0 to 31 for the other types of devices. Complete the worksheet in Table 2-2 to identify what disks are in your system's configuration. Though the worksheet shows only four devices, you can configure a maximum of 96 ra-type devices and 32 devices of other types into your system. U sing the hardware documentation that came with your system and the associated reference page for your disks, write in the disk type, the mnemonic for that disk, and the size of each partition in MB. You will need to refer back to this worksheet when completing the worksheets in the following sections. If you are upgrading from an existing ULTRIX system or installing a new system on a disk currently being used, use the chpt command with the -q option to look at the existing disk partition layout on the disk or disks you intend to use. For example, if the disk on which you want to install the system is an RA70 on unit 0, issue the following command: # chpt -q /dev/rraOa The existing disk partition layout is displayed. Table 2-2: Disk Configuration Worksheet Disk Number o Device Name ULTRIX Name Partition Partition Size in MB a b c d e f g h 1 a b c d e f g h 2 a b c d e Planning Your Disk Space 2-3 Table 2-2: (continued) Disk Number Device Name ULTRIX Name Partition Partition Size in MB f g h 3 a b c d e f g h 2.2 Planning the Swap Space The swap space is the area on a disk used by the kernel to transfer processes into and out of physical memory. The advanced installation lets you allocate two swap areas: swapl and swap2. (You can allocate additional swap space during day-to-day system management. See the Guide to Configuration File Maintenance for instructions on how to do this.) Allocate the swap I space either by accepting the default or by specifying another partition. If you choose the default allocation, the installation software allocates the swap 1 space to the b partition of the system disk. There is no default allocation for swap2 space. Note If you choose a partition that overlaps the a partition, where customized partition information resides, you will overwrite any customized partition table that describes the disk you selected and overwrite the superblock. For this reason the installation software does not include the a partition in the list of partitions available for the swap area. The size of the swap space should be at least two to three times the processor's physical memory size. If your system is devoted to users that might be running numerous large programs, your swap space will need to be more than three times the size of physical memory. If you plan to allocate a second swap space, you can divide the required size between the two. For example, if you need lOO MB of swap space, you could allocate 50 MB to the swap 1 space and 50 MB to the swap2 space. Dividing the swap space will improve swapping performance. 2-4 Planning Your Disk Space Note If you plan to allocate the crash dump space (see Section 2.3) to the same disk partition as the swap space, the swap space must be on a disk connected to the same controller as the system disk. To determine the size and record the location of the swap space areas, fill in the following blanks: 1. The memory in MB for your processor is _ _ _ __ 2. Therefore, you need MB (two or three times main memory, depending on the number and size of processes running) to accommodate your swap space. 3. Refer to the worksheet in Table 2-2 to identify partitions that are large enough for your swap spaces. 4. Record the location of the swap space as follows: Swap Space Size in MB ULTRIX Name Disk Number Partition swap! swap2 2.3 Planning the Crash Dump Space The crash dump space is the area on the disk where the kernel writes the memory contents in the event of a system crash. Allocate the crash dump space by accepting the default or by specifying another partition. You can allocate the crash dump space either to the same partition as swap 1 or swap2, or to another partition. If you choose the default allocation, the installation software allocates the crash dump space to the b partition of the system disk. The ULTRIX operating system provides two types of crash dumps: partial and full. You can use either partial or full crash dumps, but not both. Partial crash dumps, the default, write only part of the memory's contents to the crash dump space. This minimizes the amount of disk space needed to hold crash dumps. Use Table 2-3 to help determine the space needed for partial crash dumps based on physical memory size of your system and its maximum number of users. Full crash dumps write the entire contents of memory to the crash dump space. For full crash dumps, the size of crash dump space needed must be at least equal to the size of memory plus the size of the kernel, vmunix. The size of the kernel can be up to approximately 4.1 MB. See the Guide to System Crash Recovery for more information about calculating crash dump space. Note The crash dump space must be on a disk connected to the same controller as the system disk. Planning Your Disk Space 2-5 Table 2-3: Partial Crash Dump Space Requirements Physical Memory inMB Maximum Number of Users Space Needed for RiSe (MB) Space Needed for VAX (MB) 6 8 16 32 64 128 256 512 2 2 16 32 64 128 128 256 not applicable 8 14 20 28 40 40 48 6 8 10 12 16 26 26 34 To determine the size and record the location of the crash dump space, fill in the following blanks: 1. The memory in MB for your system is _ _ __ 2. The maximum number of users allowed on your system is _ _ __ 3. You need MB to accommodate your crash dump space. For partial dumps, select a value from Table 2-3. For full dumps, this value must be at least equal to the amount of memory. 4. Refer to the worksheet in Table 2-2 to identify partitions that are large enough for your crash dump space. 5. Record the ULTRIX name, disk number, and partition where you plan to allocate the crash dump space. See Table 2-2 to identify partitions that are large enough to allocate the crash dump space. ULTRIX Name Disk Number Partition 2.4 Planning the var Area The var area contains volatile, machine-specific directories and files, like tmp, spool, and adm. You can allocate the var area either as a file system on its own partition, or as a directory in the / u s r file system. If you choose the default allocation, the installation software allocates the var area as the directory /usr /var. In determining the size of the var area, you need to consider the following: • The crash dump space • The error logger • System accounting • The size of the var / adm/ r is directory, if appropriate for your system The following sections briefly describe how these items affect the size of var. Complete the worksheet in Section 2.4.5 as you work through the sections. 2-6 Planning Your Disk Space 2.4.1 Size of the var/adm/crash Directory The file system requires room to accommodate the crash dump space. When the system crashes, the savecore utility writes a partial copy (for partial dumps) or a complete copy (for full dumps) of main memory (vrncore) and the vrnunix image located in the root file system into the swap space. When the system comes back up, savecore writes these copies of vrncore and vrnunix to files located in the var / adm/ crash directory. The var / adm/ crash directory should have at least the amount of space you recorded in Section 2.3. This should give you enough space for one crash dump. See the Guide to System Crash Recovery for more information about calculating crash dump space. Fill in the first item of the worksheet in Table 2-4 with the size of the crash dump space. 2.4.2 Error Logger The var file system requires room to accommodate the error log. The error log is a record of system- and hardware-related errors in a binary file. If you are creating a new system and have never had an error log file, then estimate your requirements using the following guidelines: • The error logger records about 1 MB per week on a processor that has 25 MB of memory and is connected to two tape drives, 10 disk drives, 1 DMB serial port, and 1 Ethernet interface. If you back up or remove the error log file once a month, then you need to plan for an error log file that is about 4 MB. • Increase this recommended number if you have a processor with more memory, a greater number of peripheral devices, or peripheral devices that experience numerous errors. You should also increase the recommended number to accommodate any remote processors that log in to the local processor. • Increase this recommended number if your system is connected to a Computer Interconnect (CI) network. The error logger records errors for all systems and devices attached to the CI. Applying the first guideline in this list for each system attached to the CI, you can estimate the amount of error logging each system generates. Then add together the total for each system to give you the total error logging space your system needs. • Decrease this recommended number if you have a processor with less memory or a smaller number of peripheral devices. The Guide to the Error Logger provides more information on the error logger. Fill in the second item of the worksheet in Table 2-4 with the amount of space needed for the error logger. 2.4.3 System Accounting The adm directory in the var area contains data files generated by administrative programs such as acct, aculog, and wtrnp. The data that these programs generate can vary widely from system to system and over time. For example, the file adm/ acct in the var area can easily grow by 50 KB a day for a large system and by 5 KB for a workstation. As a general guideline for system accounting, you should allot 10 KB per day for workstations and 100 KB per day for larger systems. If you back up or remove the system accounting file once a month, then you need to plan Planning Your Disk Space 2-7 for accounting files that occupy about 300 KB for workstations and 3 MB for large systems. See the Guide to Disk Maintenance for more information on the space requirements for system accounting. Fill in the third item of the worksheet in Table 2-4 with the amount of space needed for system accounting. 2.4.4 Size of the var/adm/ris Directory If you are going to set up a network kit on your system, you can choose to transfer software subsets from distribution media to the adm/ r is directory in the var area. Anyone with a processor from the VAXstation, MicroVAX, DEC station, or certain DECsystem series of processors can then install the software subsets residing in this directory using the Ethernet. See the Guide to Sharing Software on a Local Area Network for more information on setting up the network kit. You must reserve enough space in the adm/ris directory in the var area for the software you want to install. See Appendix A (for RISC processors) or Appendix B (for VAX processors) for a brief description of each software subset and the names of any other subsets or kernel configuration file options related to its operation and the Release Notes for the subset sizes. Fill in the fourth item of the worksheet in Table 2-4 with the amount of space needed for the adm/ris directory in the var area. 2.4.5 Completing the var Worksheet Complete the worksheet in Table 2-4 to determine the space requirements for the var area. Table 2-4: var Worksheet Item Obtain number from ... Crash dump space Section 2.4.1 Error logger Section 2.4.2 System accounting Section 2.4.3 Size of the var/adm/ris directory Section 2.4.4 Total for var TOTAL If you plan on using a separate partition for the var area, record the ULTRIX name, disk number, and partition where you plan to allocate the var file system: ULTRIX Name 2-8 Planning Your Disk Space Disk Number Partition 2.5 Planning the lusr File System The lusr file system is the directory structure that contains such directories as lusr I sys, lusr I adm, and lusr Ibin. You must allocate the lusr file system, either by accepting the default or by specifying another partition. If you choose the default allocation, the installation software allocates the g partition of the system disk. In determining the size of the lusr file system, you need to consider the following: • The software subsets you plan to install on lusr • The amount of user space needed • The size of the var area if it is on the same partition as lusr The following sections briefly describe how these items affect the size of lusr. Table 2-5 contains a worksheet that you will complete by working through the sections. 2.5.1 Software Subsets Within the lusr File System The lusr file system requires room to accommodate the software subsets that will reside within it. A software subset is a collection of executable files and data files needed to perform a specific function or provide a particular class of services. For example, the Document Preparation Extensions provide tools for the online reference pages, such as nroff and catman. Use the tables in the Release Notes that list RIse and VAX subset sizes to determine the amount of space to allocate for the subsets you plan to install. The mandatory subsets are always installed. The optional subsets are not needed for your system to function; you can choose none, some, or all of the optional subsets depending on your system requirements and available space. Select the subsets that you want to install and add their sizes together. Record the totals in the spaces provided. See Table A-I (for RISe processors), or Table B-1 (for VAX processors) for descriptions of the software subsets and a list of other subsets and kernel configuration file options related to each subset. Fill in the first item of the worksheet in Table 2-5 with the amount of space needed for all the subsets you plan to install. 2.5.2 User Area The advanced installation does not provide an area for user files. You need to set up this area after the installation. However, you should still take this amount of space into consideration when planning your system. As a guideline, you should reserve at least 10MB of disk space for each user on your system. For example, if there are 10 users, you should reserve a minimum of 100 MB of disk space. If you intend to set quotas on the user area, multiply the quota for each user by the number of users to determine the amount user space. See the Guide to Disk Maintenance for information on disk quotas. Fill in the second item of the worksheet in Table 2-5 with the amount of space needed for the users directory. Planning Your Disk Space 2-9 2.5.3 var Area If you plan to place the var area on the same partition as /usr, you must add the size of the var area that you determined with the worksheet in Table 2-4 to the total of /usr. If appropriate for your system, fill in the third item of the worksheet in Table 2-5 with the amount of space needed for var. 2.5.4 Completing the lusr Worksheet Complete the worksheet in Table 2-5 to determine the space requirements for the /usr area. Table 2-5: lusr Worksheet Item Obtain Number From ... Software subsets The Release Notes Size of the user area Section 2.5.2 Size of the var area Table 2-4 for the var total Total for lusr TOTAL Refer to Table 2-2 to identify partitions that are large enough for the /usr file system. Record the ULTRIX name, disk number, and partition where you plan to allocate the /usr file system: ULTRIX Name Disk Number Partition 2.6 Determining the Disk Partition Layout After you determine how much space your system requires for each file system, you need to determine whether you can accept the default disk partition layouts or whether you want to modify the disks with the chpt command to use a customized partition layout. If you modify the partition tables for the system disk, the partitions for root and swap 1 must meet the following minimum space requirements: • The root or a partition must be at least 32,768 blocks (16 MB). • The swap or b partition must be at least 12,288 blocks (6 MB). This assumes that you plan to add a second swap device. If the modified partitions do not meet these requirements, then the advanced installation imposes the default partition table for the system disk. No other disks on the system are affected. Complete the worksheet in Table 2-6 by entering the values that you determined in the previous sections. This table will give you the complete file system layout and 2-10 Planning Your Disk Space space requirements for your system. Table 2-6: File System Worksheet Items Approximate Size Disk Partition (--) (--) Root (from Table 2-2) swap 1 (from Section 2.2) swap2 (from Section 2.2) Crash dump space (from Section 2.3) /var (from Table 2-4; fill in disk and partition lines if applicable) /usr Total: After completing the worksheet, you need to ensure that the disk partitions are laid out the way you want them. If you are installing a system for the first time, refer to Table 2-2 and to Section 4 of the ULTRIX Reference Pages for the default partition layout for your disk or disks. Compare the disk partition layout with the total values in Table 2-6. If a file system (excluding swap) is immediately going to consume more than 75 percent of its intended disk partition not including the 16 percent of the partition that the ULTRIX file system consumes, you may want to expand the disk partition, if possible. Assuming that you have a valid backup of your current system (if appropriate) and that you are experienced with ULTRIX file systems, you can modify disk partitions by choosing the System Management option of the installation procedure to enter the standalone ULTRIX environment. This environment loads a memory-resident ULTRIX kernel on your system and gives you access to the commands you need to change the partitions. See Chapter 7 for information on the standalone ULTRIX environment. 2.7 Planning the Configuration File Entries Certain layered products require that an entry be added to your system's configuration file for that product to work. For example, DEC net requires an entry in the configuration file. When you choose the kernel option corresponding to each configuration file entry, the advanced installation procedure updates the configuration file before it builds the kernel, vmunix. If you plan to use any of the features listed in Table 2-7 now or in the future, add the relevant entry during the advanced installation. If you include them during the installation, the products that use these features will function immediately after they are installed. Otherwise, when you are ready to install a product, you will need to add the necessary entry in the configuration file and then rebuild the kernel. Note that including the entry in the configuration file does not mean that the product is installed. Planning Your Disk Space 2-11 Table 2-7: Configuration File Entries Kernel Option Description Local Area Transport (LAT) Gives you the kernel options and devices required to facilitate communications with Digital's Ethernet local area terminal server. Bisynchronous Communication protocol (VAX only) Gives you access to the 2780 and 3780 remote job entry terminals. Computer Interconnect (CI) network Gives you kernel options and devices required to use the internet protocols on the CI wires. DiagnosticlUtilities Protocol (DUP) Provides a method of communication between a host class driver and a server in the controller. DUP defines the communications between a host control program and a remote program in the controller. DUP requires one of the following devices to be configured on the system: bvpssp, ci, msi, or uq. IS09660 File System Support (CDFS) Allows you to access an IS09660 formatted CDROM as a local, readonly file system. Ethernet packet filter Allows you to implement networking protocols without modifying the kernel, and allows you to monitor the network by receiving packets destined for machines other than your own. Enhanced security features Give you audit, additional identification and authentication mechanisms, and trusted path. Note that adding the audit and the additional identification and authentication mechanisms at installation time will not activate these options. See the Security Guide for Administrators for further information. DECnet Gives you the kernel options required to facilitate the use of the DECnet networking protocols. Add? All of the configuration options listed None of the configuration options listed Depending on your hardware configuration, you may need to edit your system's configuration file even if you choose to add kernel options during the advanced 2-12 Planning Your Disk Space installation. You will need to edit the configuration file in the following situations: • Your system's configuration does not conform to control status register (CSR) address assignment rules. • You have disk controllers in floating address space. • You have both KDA50 and RQDX controllers on the Q-bus. For more information on editing your system's configuration file, see the Guide to Configuration File Maintenance. Now you are ready to begin the installation. Planning Your Disk Space 2-13 Booting the System 3 Before you can install the ULTRIX software, you must prepare the hardware for the installation and then boot the system from the installation media. How you do this depends on which processor you have. If you are using a TK50 tape kit or a MT9 tape kit to boot your system, or are booting the standalone kernel for system management tasks, follow the instructions included with the kit. If you are using a CDROM optical disc to boot your system, follow the instructions in the hardware manual included with the CDROM. Another way to boot your system is over the network. You boot your system from the network when you are: • Initiating an installation from a remote server • Booting a diskless system • Booting a standalone kernel from a remote server in order to perform system management tasks To boot over the network, you must be registered as a client on a DMS or RIS server. See the Guide to Sharing Software on a Local Area Network for information on registering your system. Look for your processor in Table 3-1 and find the section in this chapter that gives booting instructions for your processor. Follow the instructions in that section and then continue the installation procedure with Chapter 4 if you are performing a basic or an advanced installation, or Chapter 5 if you are performing an upgrade installation. Table 3-1: Location of Processor-Specific Boot Instructions Processor Section DEC station 2100 Section 3.1 DEC station 3100 Section 3.1 DEC station 3100S Section 3.1 DEC station 5000, Model 100 series Section 3.2 DEC station 5000, Model 200 series Section 3.2 Personal DEC station 5000, Model 20 & 25 Section 3.2 DECsystem 3100 Section 3.1 DEC system 5000, Model 25 Section 3.2 DEC system 5000, Model 200 series Section 3.2 DECsystem 5100 Section 3.3 DECsystem 5400 Section 3.4 DECsystem 5500 Section 3.5 Table 3-1: (continued) Processor Section DEC system 5810 Section 3.6 DECsystem 5820 Section 3.6 DEC system 5830 Section 3.6 DECsystem 5840 Section 3.6 DECsystem 5900 Section 3.2 MicroVAX II Section 3.10 MicroVAX 2000 Section 3.7 MicroVAX 3100 Section 3.8 MicroVAX 3300 Section 3.9 MicroVAX 3400 Section 3.9 MicroVAX 3500 Section 3.10 MicroVAX 3600 Section 3.10 MicroVAX 3800 Section 3.10 MicroVAX 3900 Section 3.10 V AXserver 100 Section 3.10 V AXserver 2000 Section 3.7 VAX server 3100 Section 3.8 VAXserver 3300 Section 3.9 VAXserver 3400 Section 3.9 V AXserver 3500 Section 3.10 VAXserver 3600 Section 3.10 VAXserver 3800 Section 3.10 V AXserver 3900 Section 3.10 V AXserver 6000-nnn series Section 3.14 VAXstation II Section 3.10 V AXstation IIIGPX Section 3.10 V AXstation 2000 Section 3.7 VAXstation 3100 Section 3.8 VAXstation 3200 Section 3.10 V AXstation 3500 Section 3.10 V AXstation 3520 Section 3.11 VAXstation 3540 Section 3.11 VAX-11/750 Section 3.12 VAX-11/780 Section 3.13 VAX-11/785 Section 3.13 VAX 6000-nnn series Section 3.14 VAX 6210 Section 3.14 VAX 6220 Section 3.14 VAX 6230 Section 3.14 3-2 Booting the System Table 3-1: (continued) Processor Section VAX 6240 Section 3.14 VAX 6310 Section 3.14 VAX 6320 Section 3.14 VAX 6330 Section 3.14 VAX 6340 Section 3.14 VAX 6350 Section 3.14 VAX 6360 Section 3.14 VAX 6410 Section 3.14 VAX 6420 Section 3.14 VAX 6430 Section 3.14 VAX 6440 Section 3.14 VAX 6450 Section 3.14 VAX 6460 Section 3.14 VAX 6510 Section 3.14 VAX 6520 Section 3.14 VAX 6530 Section 3.14 VAX 6540 Section 3.14 VAX 6550 Section 3.14 VAX 6560 Section 3.14 VAX 8200 Section 3.15 VAX 8250 Section 3.15 VAX 8300 Section 3.15 VAX 8350 Section 3.15 VAX 8500 Section 3.16 VAX 8530 Section 3.16 VAX 8550 Section 3.16 VAX 8600 Section 3.17 VAX 8650 Section 3.17 VAX 8700 Section 3.16 VAX 8800 Section 3.16 VAX 8810 Section 3.16 VAX 8820 Section 3.18 VAX 8830 Section 3.18 VAX 8840 Section 3.18 VAX 9000 Section 3.19 Booting the System 3-3 3.1 DECstation 2100/3100/31 OOS or DECsystem 3100 Processor To prepare the DEC station 2100/3100/3100S or DECsystem 3100 hardware: 1. Turn on power to the console terminal and all additional peripheral devices. 2. Turn on power to the processor. 3. Remove any TKSO tape cartridges and CDROM optical discs from their associated drives. The console subsystem now prints an initial display and ends with the console mode prompt: » The boot command you type depends on the software distribution kit: TKSO, CDROM, or network. The boot command for each distribution kit is described in this section. 3.1.1 Booting from the TK50 Tape Cartridge Kit Follow the instructions included with your TKSO tape kit for inserting the tape into the tape drive. Follow this procedure to boot the system: 1. Make sure that your tape cartridges are write-protected. 2. Load the tape cartridge labeled ULTRIX AND UWS V4.3 BOOTIUPGRADE into the tape drive. Ensure the tape is online and ready to use. 3. Use the following command to determine the unit number of the drive for your device: » test -c A display appears that shows what is assigned to each unit number on your system. 4. Use a command with the following syntax to boot your system: boot -f tz(O, unit-number) Replace unit-number with the unit number of your tape drive. The following example shows the command to boot the system from tape drive number S. » boot -f tz(O,S) Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. 3.1.2 Booting from the CDROM Optical Disc Kit If your CDROM optical disc is not already in its caddy, follow the instructions in the hardware manual for inserting the optical disc into the caddy. 3-4 Booting the System Follow this procedure to boot the system: 1. Load the CDROM optical disc with the label appropriate for your machine architecture, either ULTRIXlUWS V4.3 (RISC) SUPPORTED or ULTRIXlUWS V4.3 (VAX) SUPPORTED, into the drive. Wait for the drive to be on line and ready. 2. Use the following command to determine the unit number of the drive for your device: » test -c A display appears that shows what is assigned to each unit number on your system. 3. Use a command with the following syntax to boot your system: boot -f rz(O, unit-number,O)vmunix Replace unit-number with the unit number of your optical disc drive. The following example shows the command to boot the system from optical disc drive number 4: » boot -f rz(O,4,O)vmunix Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. 3.1.3 Booting from the Network To boot the system over the network, type a command with the following syntax at the console mode prompt: boot -f mop(net-inteiface) If you have more than one network interface, replace net-inteiface with the number of the interface you want to use. If you have only one network interface, replace net-inteiface with zero (0). Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. Booting the System 3-5 3.2 DECstation 5000 Series, DECsystem 5000 Series, Personal DECstation 5000 Series, and the DECsystem 5900 Processor To prepare these processors: 1. Tum on power to the console tenninal and all additional peripheral devices. 2. Tum on power to the processor. 3. Remove any TK50 tape cartridges and CDROM optical discs from their associated drives. The console subsystem now prints an initial display and ends with the console mode prompt: » The boot command you type depends on the software distribution kit: TK50, CDROM, or network. Before beginning, you must detennine the slot and device numbers of your boot device. 3.2.1 Determining the Slot and Device Numbers of Your Boot Device The instructions in this section assume that if you have multiple disk drives, CDROM drives, or tape drives, you know which drive is your boot device. If you are booting from a Small Computer System Interconnect (SCSI) device, check the cabling of your hardware to determine which controller you are booting from. 3.2.1.1 Determining the Slot Number (Default) To detennine which controllers and devices are configured on your system, type the following command at the console prompt: » cnfg This command displays the options present on the system. Your system will display output similar to the following (the output will differ depending on your system configuration): 7:KN02-AA 6: PMAD-AA S:PMAZ-AA 2:PMAZ-AA 1 :PMAG-AA DEC DEC DEC DEC DEC VS.3a VS.3a vS.3a vS.3a T3.0a TCFO TCFO TCFO TCFO TCFO (16 MB) (enet:08-00-2b-16-8S-7e) (SCSI=7) (SCSI=7) (PXG--D=24) The first column displays the slot numbers of the device controllers. The last column displays the devices in each slot. If your system has more than one device in a particular slot, a display similar to the following appears: 3: KN02-BA DEC XS.4g TCFO 1: PMAG-CA DEC VS.3a TCFO 3-6 Booting the System (32 MB) (enet: 08-00-2b-16-S8-d6) (SCSI = 7) (PX -- D=8) 3.2.1.2 Determining the Boot Device Number To determine the device number of your boot device, type a command with the following syntax: cnfg sloCnumber For example, to determine the device number of a SCSI disk drive with a controller in slot 5, type the following command: » cnfg 5 The system displays a table similar to the following: PMAZ-AA 5: DEC DEV PID rz3 tz5 RZ56 V5.3a (C) DEC TCFO (SCSI VID REV DEC 0200 = 7) SCSI DEV DIR SEQ In the previous example, the disk drive is identified by the letters "rz". The device number for the disk drive is 3 (rz3). The tape drive is identified by the letters "tz". The device number for the tape drive is 5 (tz5). Now that you know the slot number and the device number, you can boot your system or set your system's environmental boot variable. Follow the directions given in the appropriate booting sections. If the command shows that you have multiple devices configured on the same controller, you will have to know which device is the boot device. If you do not know which device is the boot device, consult your system administrator. 3.2.2 Booting from the TK50 Tape Cartridge Kit Follow the instructions included with your TK50 tape kit for inserting the TK50 into the tape drive. Follow this procedure to boot the system: 1. Make sure that your TK50 tape cartridges are write-protected. 2. Load the tape cartridge labeled ULTRIX AND UWS V4.3 (RISC) BOOT UPGRADE into the tape drive. Ensure the tape is online and ready to use. 3. To determine the device number of the SCSI tape, use the same slot number and device number that were determined by the cnfg command in Section 3.2.1.2. For example to boot a SCSI tape (tz) at slot 5, drive 5, type the following command: » boot 5/tz5 You have completed booting your system. Continue the installation procedure with Chapter 4. 3.2.3 Booting from the CDROM Optical Disc Kit If your CDROM optical disc is not already in its caddy, follow the instructions in the hardware manual for inserting the optical disc into the caddy. Booting the System 3-7 Follow this procedure to boot the system: 1. Load the CDROM optical disc with the label appropriate for your machine architecture, either ULTRIXlUWS V4.3 (RISC) SUPPORTED or ULTRIXlUWS V4.3 (VAX) SUPPORTED, into the drive. Wait for the drive to be on line and ready. 2. Use a command with the following syntax to boot your system: boot slocnumberlrzdevice_numberlvmunix Replace slot-number with the slot number of the CDROM controller. Replace device-number with the device number of your optical disc drive. For example, to boot the system from optical disc drive number 4 on slot number 1, type the following command: » boot l/rz4/vmunix You have completed booting your system. Continue the installation procedure with Chapter 4. 3.2.4 Booting from the Network To boot the system from the network, use a command with the following syntax: boot sloCnumberimop Replace slot_number with the slot number of the network controller. For example, to boot from the network on slot number 6, type the following command: » boot 6/mop Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. 3-8 Booting the System 3.3 DECsystem 5100 Processor To prepare the DECsystem 5100 hardware: 1. Turn on power to the console terminal and all additional peripheral devices. 2. Turn on power to the processor. 3. Remove any TK50 tape cartridges and CDROM optical discs from their associated drives. The console subsystem now prints an initial display and ends with the console mode prompt: » The boot command you type depends on the software distribution kit: TK50, CDROM, or network. The boot command for each distribution kit is described in this section. 3.3.1 Booting from the TK50 Tape Cartridge Kit Follow the instructions included with your TK50 tape kit for inserting the tape into the tape drive. Follow this procedure to boot the system: 1. Make sure that your TK50 tape cartridges are write-protected. 2. Load the tape cartridge labeled ULTRIX AND UWS V4.3 (RISC) BOOTIUPGRADE into the tape drive. Ensure the tape is online and ready to use. 3. Use the following command to determine the unit number of the drive for your device: » conf A display appears that shows what is assigned to each unit number on your system. 4. Use a command with the following syntax to boot your system: boot -f tz(O, unit-number} Replace unit-number with the unit number of your tape drive. The following example shows the command to boot the system from tape drive number 5: » boot -f tz(O,5) Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. 3.3.2 Booting from the CDROM Optical Disc Kit If your CDROM optical disc is not already in its caddy, follow the instructions in the hardware manual for inserting the optical disc into the caddy. Booting the System 3-9 Follow this procedure to boot the system: 1. Load the CDROM optical disc with the label appropriate for your machine architecture, either ULTRIXlUWS V4.3 (RISC) SUPPORTED or ULTRIXlUWS V4.3 (VAX) SUPPORTED, into the drive. Wait for the drive to be on line and ready. 2. Use the following command to determine the unit number of the drive for your device: » conf A display appears that shows what is assigned to each unit number on your system. 3. Use a command with the following syntax to boot your system: boot -f rz{O,unit-number,O)vmunix Replace unit-number with the unit number of your optical disc drive. The following example shows the command to boot the system from optical disc drive number 4: » boot -f rz(O,4,O)vmunix Next, the installation software displays some system information, followed by the memory and hardware c show device A display appears that shows what is assigned to each unit number on your system. Record the unit number of your tape drive, then enter the following command to return to the RISC console: »> exit 4. Use a command with the following syntax to boot your system: boot -f tm(O, unit-number) Replace unit-number with the unit number of your tape drive. The following example shows the command to boot the system from tape drive number 0: » boot -f tm(O,O) Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. Booting the System 3-11 3.5 DECsystem 5500 Processor To prepare the DECsystem 5500 series processor hardware: 1. Turn on power to the console terminal and all additional peripheral devices. 2. Turn on power to the processor. 3. Remove any TK50 tape cartridges and CDROM optical discs from their associated drives. The console subsystem now prints an initial display and ends with the console mode prompt: » The boot command you type depends on the software distribution kit: TK50, CDROM, or network. Before beginning, you must determine the slot and device numbers of your boot device. Follow this procedure to boot the system: 1. Make sure that your tape cartridges are write-protected. 2. Load the tape cartridge labeled ULTRIX AND UWS V4.3 (RISC) BOOTIUPGRADE into the tape drive. Ensure the tape is online and ready to use. 3. To determine the unit number of the drive for your device, first enter this command to invoke the VAX console: » maint When the V AX console prompt appears, enter the following command: »> show device A display appears that shows what is assigned to each unit number on your system. Record the unit number of your tape drive, then enter the following command to return to the RISC console: »> exit 3.5.1 Booting from the SCSI Tape Device Use a command with the following syntax to boot your system: boot -f tz(O, unit-number) Replace unit-number with the unit number of your tape drive. The following example shows the command to boot the system from tape drive number 0: » boot -f tz(O,O) You have completed booting your system. Continue the installation procedure with Chapter 4. 3-12 Booting the System 3.5.2 Booting from the Q-bus Tape Device Use a command with the following syntax to boot your DECsystem 5500 from a Q-bus tape: boot -f tm(O, unit-number) Replace unit-number with the unit number of your tape drive. The following example shows the command to boot your DECsystem 5500 from tape drive number 0: » boot -f tm(O,O) You have completed booting your system. Continue the installation procedure with Chapter 4. 3.5.3 Booting from the CDROM Optical Disc Kit If your CDROM optical disc is not already in its caddy, follow the instructions in the hardware manual for inserting the optical disc into the caddy. Follow this procedure to boot the system: 1. Load the CDROM optical disc with the label appropriate for your machine architecture, either ULTRIXlUWS V4.3 (RISC) SUPPORTED or ULTRIXlUWS V4.3 (VAX) SUPPORTED, into the drive. Wait for the drive to be on line and ready. 2. Use the following command to determine the unit number of the drive for your device: » show devices A display appears that shows what is assigned to each unit number on your system. 3. Use a command with the following syntax to boot your system: boot -f rz(controller-number, unit-number,O)vmunix Replace controller-number with the controller number. Replace unit-number with the unit number of your optical disc drive. The following example shows the command to boot the system from optical disc drive number 4: » boot -f rz(O,4,O)vmunix Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. 3.5.4 Booting from the Network To boot the system over the network, type a command with the following syntax at the console mode prompt: boot -f mop(net-inteiface) Booting the System 3-13 If you have more than one network interface, replace net-inteiface with the number of the interface you want to use. If you have only one network interface, replace net-inteiface with zero (0). Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. 3-14 Booting the System 3.6 DECsystem 5810/5820/5830/5840 Processor To prepare the DECsystem 5810/5820/5830/5840 hardware: 1. Tum on power to the console terminal and all additional peripheral devices. 2. Tum on power to the processor. 3. Remove any TK50 or TK70 tape cartridges from their associated drives. The console subsystem now prints an initial display and ends with the console mode prompt: » Follow the instructions included with your TK50 tape kit for inserting the tape into the tape drive. Follow this procedure to boot the system: 1. Make sure that your tape cartridges are write-protected. 2. Load the tape cartridge labeled ULTRIX AND UWS V4.3 (RISC) BOOT UPGRADE into the tape drive. Ensure the tape is on line and ready to use. 3. To determine the node number of the drive for your device, use the following command: » show config A display, similar to the following, appears on your screen. It shows shows what is assigned to each slot number on your system: 1+ 2 9+ E+ XBI 1+ 2+ 4+ 6+ C+ Type KN58A/A KN58A/B MS62A DWMBA/A E DWMBA/B KDB50 CIBCA TBK70 DEBNI (8081) Rev 0000 (4001) (2001) 0002 0002 (2107 ) (010E) (0108) (410B) (0118) OOOA 131C 41C2 0307 0100 Record the slot number of your XMI-to-BI bus adapter (XBI), which is hexadecimal E in the example. Also record the node number of your TBK70 controller, which is 6 in the example. (Do not include the plus sign (+) that appears in the output.) 4. Use a command with the following syntax to boot your system: boot -f tms(/xOxslot-numberlbnode-number, unit-number) Replace slot-number with the slot number of your XBI adapter. Replace nodenumber with the node number on the XBI where your TBK70 controller is located. Replace unit-number with the unit number of your TBK70 controller. The unit number is always the same as the node number on the XBI where your TBK70 controller is located. The following example shows the command to boot the system from XBI slot E Booting the System 3-15 for a TBK70 controller located on XBI node 6: » boot -f tms(/xOxe/b6,6) Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. 3-16 Booting the System 3.7 MicroVAX 2000, VAXserver 2000, or VAXstation 2000 Processor The following instructions assume you have no bootable software on any device in your system. To prepare the Micro VAX 2000, VAXserver 2000, or VAXstation 2000 hardware: 1. Set the system unit on/off switch to 1 (on). 2. Turn on power to the disk expansion box (if present). 3. Tum on power to the TZKSO expansion box (if present). 4. Turn on power to peripheral devices, such as printers or modems. S. Remove any TKSO tape cartridges and RXSO or RX33 diskettes from their associated drives. After about 20 seconds, the monitor displays a power-up test sequence similar to: KA410 Vl. 0 F ... E ... D ... C ... B ... A ... 9 ... 8 ... 7 ... 6 ... 5 ... 4 ... 3 ... 2 ... 1 ... The first line is hardware revision information. The second line is a countdown of the system self-test diagnostics. The countdown may be followed by some status or error messages. The owner's manual explains these status and error messages and also how you can tell whether the self-test passed. 6. After the system finishes the self-test countdown, press the halt button on the rear of the system unit. The console mode prompt appears: »> You are now ready to boot the system. The boot command you type depends on the software distribution kit: TKSO or network. The boot command for each distribution kit is described in this section. 3.7.1 Booting from the TK50 Tape Cartridge Kit Follow the instructions included with your TKSO tape kit for inserting the TKSO tape into the tape drive. Follow this procedure to boot the system: 1. Make sure that your tape cartridges are write-protected. 2. Load the tape cartridge labeled ULTRIX AND UWS V4.3 (VAX) BOOT/UPGRADE into the tape drive. Ensure the tape is on line and ready to use. 3. Type the following at the console mode prompt: »> b muaO Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. Booting the System 3-17 3.7.2 Booting from the Network To boot the system over the network, type the following command at the console mode prompt: »> b esaO Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. 3-18 Booting the System 3.8 MicroVAX 3100, VAXserver 3100, or VAXstation 3100 Processor The following instructions assume you have no bootable software on any device in your system. To prepare the MicroVAX 3100, VAX server 3100, or VAXstation 3100 hardware: 1. Set the monitor on/off switch to 1 (on). 2. Tum on power to all disk expansion boxes (if present). 3. Tum on power to all TZK50 and CDROM optical disc expansion boxes (if present). 4. Set the system unit on/off switch to 1 (on). 5. Tum on power to peripheral devices, such as printers and modems. 6. Remove any TK50 tape cartridges and CDROM optical discs from their associated drives. After about 20 seconds, the monitor displays a power-up test sequence similar to this: KA42-B Vl. 0 F ... E ... D ... c ... B ... A ... 9 ... 8 ... 7 ... 6 ... 5 ... 4 ... 3 ... 2 ... 1 ... The first line is hardware revision information. The second line is a countdown of the system self-test diagnostics. The countdown may be followed by some status or error messages. The owner's manual explains these status and error messages and also how you can tell whether the self-test passed. 7. Press the halt button on the rear of the system unit after the system finishes the self-test countdown. The console mode prompt appears: »> You are now ready to type the boot command. The boot command you type depends on the software distribution kit: TK50, CDROM, or network. The boot command for each distribution kit is described in this section. 3.8.1 Booting from the TK50 Tape Cartridge Kit Follow the instructions included with your TK50 tape kit for inserting the TK50 tape into the tape drive. Follow this procedure to boot the system: 1. Make sure that your tape cartridges are write-protected. 2. Load the tape cartridge labeled ULTRIX AND UWS V4.3 (VAX) BOOTIUPGRADE into the tape drive. Ensure the tape is on line and ready to use. Booting the System 3-19 3. Type the following command to determine the drive from which to boot: »> show device After several seconds, a nine-column table is displayed. You need the following information from this table: - The logical device name, which is shown in column 1. - The physical device name, which is shown in column 8. 4. Type the boot command at the console mode prompt, using the logical device name determined by the show device output. For example, a TZ30 or TZK50 device connected to SCSI controller A with SCSI bus ID number 5 would require a boot command like the following: »> b mkaSOO Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. 3.8.2 Booting from the COROM Optical Disc Kit If your CDROM optical disc is not already in its caddy, follow the instructions in the hardware manual for inserting the optical disc into the caddy. Follow this procedure to boot the system: 1. Load the CDROM optical disc with the label appropriate for your machine architecture, either ULTRIXlUWS V4.3 (RISC) SUPPORTED or ULTRIXlUWS V4.3 (VAX) SUPPORTED, into the drive. Wait for the drive to be on line and ready. 2. Type the following command to determine the drive from which to boot: »> show device After several seconds, a nine-column table is displayed. You need the following information from this table: - The logical device name, which is shown in column 1. - The physical device name, which is shown in column 8. 3. Type the boot command at the console mode prompt, using the logical device name determined by the show device output. For example, an RRD40 device connected to SCSI controller B with SCSI bus ID number 4 would require a boot command like the following: »> b dkb400 Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. 3-20 Booting the System 3.8.3 Booting from the Network To boot the system over the network, type the following command at the console mode prompt: »> b esaO Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. Booting the System 3-21 3.9 MicroVAX 3300/3400 or VAXserver 3300/3400 Processor To prepare the MicroVAX 3300/3400 or VAXserver 3300/3400 hardware: 1. Tum on power to the console terminal and all additional peripheral devices. 2. Set the front panel HALT ENABLEIDISABLE switch to the halt enabled position. 3. Tum on power to the processor. 4. Remove any TK50 tape cartridges from their associated drives. The console subsystem now prints an initial display similar to the following on the console terminal: KA640-A T3.0-10, VMB 2.2 Performing normal system tests. 41. .40 .. 39 .. 38 .. 37 .. 36 .. 35 .. 34 .. 33 .. 32 .. 31. .30 .. 29 .. 28 .. 27 .. 26 .. 25 .. 24 .. 23 .. 22 .. 21. .20 .. 19 .. 18 .. 17 .. 16 .. 15 .. 14 .. 13 .. 12 .. 11. .10 .. 09 .. 08 .. 07 .. 06 .. 05 .. 04 .. 03 .. Tests completed. Then the console mode prompt appears: »> You are now ready to type the boot command. The boot command you type depends on the software distribution kit: TK50 or network. The boot command for each distribution kit is described in this section. 3.9.1 Booting from the TK50 Tape Cartridge Kit Follow the instructions included with your TK50 tape kit for inserting the TK50 tape into the tape drive. Follow this procedure to boot the system: 1. Make sure that your tape cartridges are wri~e-protected. 2. Load the tape cartridge labeled ULTRIX AND UWS V4.3 (VAX) BOOT/UPGRADE into the tape drive. Ensure the tape is online and ready to use. 3. Type the following command at the console mode prompt: »> b muaO Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. 3.9.2 Booting from the Network To boot the system over the network, type the following command at the console 3-22 Booting the System mode prompt: »> b esaO Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. Booting the System 3-23 3.10 MicroVAX II, MicroVAX 3500/3600/3800/3900, VAXserver 100/3500/3600/3800/3900, VAXstation 3200/3500, VAXstation II, or VAXstation II/GPX Processor This section describes how to boot the following processors: • Micro VAX II • MicroV AX 3500/3600/3800/3900 • VAXserver 100/35001360013800/3900 • VAXstation 3200/3500 • VAXstation II • VAXstation IIIGPX To prepare the hardware: 1. Turn on power to the console terminal and all additional peripheral devices. 2. Make sure the HALT, write-protect, and READY switches (located on the processor's front panel) are set to their out positions. 3. Set the back panel HALT ENABLEIDISABLE switch to the halt enabled position. 4. Turn on power to the processor. 5. Remove any TK50 tape cartridges from their associated drives. The console subsystem now prints an initial display similar to the following on the console terminal: KA630-A.Vl.3 Performing normal system tests. 7 .. 6 .. 5 .. 4 .. 3 .. Tests completed. Then the console mode prompt appears: »> You are now ready to type the boot command. The boot command you type depends on the software distribution kit: TK50 or network. The boot command for each distribution kit is described in this section. 3.10.1 Booting from the TK50 Tape Cartridge Kit Follow the instructions included with your TK50 tape kit for inserting the TK50 tape into the tape drive. Follow this procedure to boot the system: 1. Make sure that your tape cartridges are write-protected. 2. Load the tape cartridge labeled ULTRIX AND UWS V4.3 (V AX) BOOTIUPGRADE into the tape drive. Ensure the tape is online and ready to use. 3-24 Booting the System 3. Type the following command at the console mode prompt: »> b muaO Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. 3.10.2 Booting from the Network To boot the system over the network, type the following at the console mode prompt: »> b xqaO Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. Booting the System 3-25 3.11 V AXstation 3520 or VAXstation 3540 Processor The following instructions assume you have no bootable software on any device in your system. To prepare the VAXstation 3520 or V AXstation 3540 hardware: 1. Set the monitor on/off switch to 1 (on). 2. Set the system unit on/off switch to 1 (on). 3. Tum on power to the CDROM box (if present). 4. Tum on power to peripheral devices, such as printers and modems. 5. Remove any TK50 tape cartridges and CDROM optical discs from their associated drives. After about 20 seconds, the monitor displays a power-up test sequence similar to this: KA60 Vl.O F .. E .. D .. c .. B .. A .. 9 .. 8 .. 7 .. 6 .. 5 .. 4 .. 3 .. 2 .. 1. .0 Tests complete. The first line is hardware revision information. The second line is a countdown of the system self-test diagnostics. The countdown may be followed by some status or error messages. The owner's manual explains these status and error messages and also how you can tell whether the self-test passed. 6. Press the halt button on the front of the system unit after the system finishes the self-test count down. The console mode prompt appears: CPUlc»> You are now ready to type the boot command. The boot command you type depends on the software distribution kit: TK50, CDROM, or network. The boot command for each distribution kit is described in this section. 3.11.1 Booting from the TK50 Tape Cartridge Kit Follow the instructions included with your TK50 tape kit for inserting the TK50 tape into the tape drive. Follow this procedure to boot the system: 1. Make sure that your tape cartridges are write-protected. 2. Load the tape cartridge labeled ULTRIX AND UWS V4.3 (VAX) BOOT/UPGRADE the tape drive. Ensure the tape is online and ready to use. 3. Type the following command at the console mode prompt: »> b muaO Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. 3-26 Booting the System 3.11.2 Booting from the CDROM Optical Disc Kit If your CDROM optical disc is not already in its caddy, follow the instructions in the hardware manual for inserting the optical disc into the caddy. Follow this procedure to boot the system: 1. Load the CDROM optical disc with the label appropriate for your machine architecture, either ULTRIXlUWS V4.3 (RISC) SUPPORTED or ULTRIXlUWS V4.3 (VAX) SUPPORTED, into the drive. Wait for the drive to be on line and ready. 2. Type the following command to determine the drive from which to boot: »> show scsi A seven-column table is displayed. This table contains the commands for possible devices from which to boot. 3. Look at column 4, labeled DEVNAM, which contains device names. Find the RRD40 or RRD42 device name in the list. 4. Find the corresponding boot command in column 2, labeled VMB, which contains the virtual memory boot command for each device. 5. Type the appropriate boot command from the list in column 2, for example: »> b dka600 Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. 3.11.3 Booting from the Network To boot the system over the network, type the following command at the console mode prompt: »> b esaO Next, the installation software displays some system information, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. Booting the System 3-27 3.12 VAX-11nSO Processor To prepare the VAX-111750 hardware: 1. Tum on power to the processor. 2. Set the processor power-on action switch to HALT and the rotary key switch to LOCAL. It makes no difference how the boot device switch is set during the installation. 3. Make sure power is on for the console terminal and all additional peripheral devices. 4. Halt the processor so that the console terminal displays the console mode prompt: »> Follow this procedure to boot the system: 1. Insert the TU58 tape cassette labeled ULTRIX V4.2 (VAX) TU58 BOOT 111 into the console TU58 drive on the front of the processor. 2. Type the following command at the console mode prompt: »> b ddaO After the boot media has been read, a message similar to the following displays: Please remove the volume "ULTRIX" from the console drive. Insert the first standalone system volume and enter "YES" when ready: 3. Remove the TU58 tape cassette labeled ULTRIX V4.2 (VAX) TU58 BOOT Ill. 4. Insert the first standalone system volume, labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX TU58 #1. Type YES at the prompt. More system information appears, followed by a display similar the following: Resuming load operation on volume "", please stand by . . . Load the TU58 labeled 'STANDALONE ULTRIX TU58 #2'. Press the Return key when ready. 5. Remove the TU58 tape cassette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX TU58 #1, replace it with the TU58 tape cassette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX TU58 #2, and press Return. More system information appears, followed by a display similar the following: Load the TU58 labeled 'STANDALONE ULTRIX TU58 #3'. Press they Return key when ready. 6. Remove the TU58 tape cassette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX TU58 #2, replace it with the TU58 tape cassette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX TU58 #3, and press Return. 3-28 Booting the System More system information appears, followed by a display similar the following: Load the TU58 labeled 'STANDALONE ULTRIX TU58 #4'. Press the Return key when ready. 7. Remove the TU58 tape cassette labeled ULTRIX V4.3 (V AX) STANDALONE ULTRIX TU58 #3, replace it with the TU58 tape cassette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX TU58 #4, and press Return. The installation software displays the memory and hardware configurations. 8. Remove the TU58 tape cassette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX TU58 #4. 9. Reload the TU58 tape cassette labeled ULTRIX V4.2 (VAX) TU58 BOOT 111. This media is necessary for booting your system if your configuration requires access to hardware microcode. You have completed booting your system. Continue the installation procedure with Chapter 4. Booting the System 3-29 3.13 VAX-11nSO or VAX-11nS5 Processor To prepare the VAX-111780 or VAX-111785 hardware: 1. Tum on power to the processor. 2. Set the restart switch to OFF and the rotary key switch to LOCAL. 3. Make sure power is on for the console terminal and all additional peripheral devices. 4. Halt the processor so that the console terminal displays the console mode prompt: »> Follow this procedure to boot the system: 1. Remove the RXOI console diskette that is in the drive inside the processor. 2. Insert the RXOI diskette labeled ULTRIX V4.2 RXOI BOOT 111. The diskette label should point toward the handle of the diskette drive. 3. Type the following at the console mode prompt: »> b After the boot media has been read, a message similar to the following displays: Please remove the volume "ULTRIX" from the console drive. Insert the first standalone system volume and enter "YES" when ready: 4. Remove the RXOI diskette labeled ULTRIX V4.2 RXOI BOOT 111. 5. Insert the first standalone system volume, labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RXOI #1. Type YES to the prompt. More system information appears, followed by a display similar to the following: Resuming load operation on volume "", please stand by . . . Load the RXOl labeled 'STANDALONE ULTRIX RXOl #2'. Press the Return key when ready. 6. Remove the RXOI diskette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RXOI #1, replace it with the RXOI diskette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RXOI #2, and press Return. A display similar to this appears: Load the RXOl labeled 'STANDALONE ULTRIX RXOl #3'. Press the Return key when ready. 7. Remove the RXOI diskette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RXOI #2, replace it with the RXOI diskette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RXOI #3, and press Return. The installation software displays the memory and hardware configurations. 3-30 Booting the System A display similar to this appears: Load the RXOl labeled 'STANDALONE ULTRIX RXOl #4'. Press the Return key when ready. 8. Remove the RXOI diskette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RXOI #3, replace it with the RXOI diskette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RXOI #4, and press Return. 9. Remove the RXOI diskette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RXOI #4. 10. Reload the RXOI diskette labeled ULTRIX V4.2 RXOI BOOT 111. You have completed booting your system. Continue the installation procedure with Chapter 4. Booting the System 3-31 3.14 VAX 6000-nnn Series or VAXserver 6000-nnn Series Processor This section describes how to boot the following processors: • VAX 6000-210/220/230/240 • VAX 6000-310/320/330/340/350/360 • VAX 6000-410142014301440/450/460 • VAX 6000-510/520/530/540/550/560 Note that VAX server 6000-nnn processors were fonnerly known as VAX server 6210/6220 or VAX server 6310/6320/6330/634016350/6360 processors. To prepare the hardware: 1. Turn on power to the processor. 2. Turn on power for the console terminal and all additional peripheral devices. 3. Halt the processor so that the console terminal displays the console mode prompt: »> The boot command you type depends on whether or not your system has a CIBCAAA or a CIBCA-AB controller. If your system has a CIBCA-AA controller, continue with Section 3.14.2. If your system has a CIBCA-AB controller, continue with Section 3.14.3. Otherwise, continue with Section 3.14.1. 3.14.1 ~ooting from the TK50 Tape Cartridge Kit Follow the instructions included with your TK50 tape kit for inserting the tape into the tape drive. Then, follow this procedure to boot your system. 1. Make sure that your TK50 tape cartridges are write-protected. 2. Load the tape cartridge labeled ULTRIX AND UWS V4.3 (VAX) BOOTIUPGRADE into the tape drive. Ensure the tape is online and ready to use. 3. Type the following ,command at the console mode prompt to begin the installation: »> b /r5:10008 csal Next, the installation software displays some system infonnation, followed by the memory and hardware configurations. You have completed booting your system. Continue the installation procedure with Chapter 4. 3.14.2 Booting from a System with a CIBCA-AA Controller Follow the instructions included with your TK50 tape kit for inserting the tape into the tape drive. Then, follow this procedure to boot a system with a console tape: 1. Make sure that your TK50 tape cartridges are write-protected. 2. Load the console tape supplied with your system into your console drive. 3-32 Booting the System 3. Type the following command at the console mode prompt: »> b /r5:10008 csal After the boot media has been read, a message similar to the following is displayed: Please remove the volume " CONSOL " from the console drive. Load the first standalone system volume into the console drive and enter "YES" when ready: 4. Remove the console tape cartridge supplied with your processor. 5. Load the tape cartridge labeled ULTRIX AND UWS V4.3 (VAX) BOOTIUPGRADE into the console drive. Ensure the tape is online and ready to use. Type YES to the prompt. More system information appears, followed by a display similar to the following: Resuming load operation on volume "", please stand by . . . The installation software displays the memory and hardware configurations. 6. Remove the TK50 tape cartridge kit. 7. Reload the console tape cartridge supplied with your processor. This media is necessary for booting your system. You have completed booting your system. Continue the installation procedure with Chapter 4. 3.14.3 Booting from a System with a CISCA-AB Controller Follow the instructions included with your TK50 tape kit for inserting the tape into the tape drive. Then, follow this procedure to boot a system: 1. Make sure that your TK50 tape cartridges are write-protected. 2. Load the tape cartidge labeled ULTRIX AND UWS V4.3 (VAX) BOOTIUPGRADE into the console drive. Ensure the tape is online and ready to use. 3. Type the following command at the console mode prompt: »> b /r5:10008 csal You have completed booting your system. Continue the installation procedure with Chapter 4. Booting the System 3-33 3.15 VAX 8200/8250 or VAX 8300/8350 Processor To prepare the VAX 8200/8250 or VAX 8300/8350 hardware: 1. Tum on power to the processor. 2. Set the processor key switch 1 to ENABLE. Set the processor key switch 2 to HALT. 3. Make sure power is on for the console terminal and all additional peripheral devices. 4. Halt the processor. 5. Press the front panel Reset button and wait for the console mode prompt: »> Follow this procedure to boot the system: 1. Load the RX50 diskette labeled ULTRIX V4.2 (VAX) RX50 BOOT 111 in the processor's removable drive. Use the left-hand drive if your unit is vertically positioned; use the uppermost drive if your unit is horizontally positioned. Make sure the orange arrow on the diskette lines up with the orange bar on the drive; otherwise, the boot procedure will fail. 2. Type the following at the console mode prompt: »> b csal After the boot media has been read, a message similar to the following displays: Please remove the volume "ULTRIX" from the console drive. Insert the first standalone system volume and enter "YES" when ready: 3. Remove the RX50 diskette labeled ULTRIX V4.2 (VAX) RX50 BOOT 111. 4. Insert the first standalone system volume, labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RX50 #1. Type YES to the prompt. More system information appears, followed by a display similar to the following: Resuming load operation on volume "", please stand by . . . Load the RX50 labeled 'STANDALONE ULTRIX RX50 #2'. Press the Return key when ready. 5. Remove the RX50 diskette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RX50 #1, replace it with the RX50 diskette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RX50 #2, and press Return. More system information appears, followed by a display similar to the following: Load the RX50 labeled 'STANDALONE ULTRIX RX50 #3'. Press the Return key when ready. 6. Remove the RX50 diskette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RX50 #2, replace it with the RX50 diskette labeled ULTRIX V4.3 3-34 Booting the System (VAX) STANDALONE ULTRIX RX50 #3, and press Return. The installation software displays the memory and hardware configurations. 7. Remove the RX50 diskette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RX50 #3. 8. Reload the RX50 diskette labeled ULTRIX V4.2 (VAX) RX50 BOOT Ill. This media is necessary for booting your system if your configuration requires access to hardware microcode. You have completed booting your system. Continue the installation procedure with Chapter 4. Booting the System 3-35 3.16 VAX 8500/8530/8550, VAX 8700, or VAX 8800/8810 Processor To prepare the VAX 8500/8530/8550, VAX 8700, or VAX 8800/8810 hardware: 1. Tum on power to the processor. 2. Tum on power to the console subsystem. 3. Initialize the system with the @sys in i t command procedure. 4. Tum on power to all additional peripheral devices. 5. Halt the processor so that the console terminal displays the console mode prompt: »> Follow this procedure to boot the system: 1. Load the RX50 diskette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RX50 #1 into the console subsystem's diskette drive unit O. Use the left-hand drive if your unit is vertically positioned; use the uppermost drive if your unit is horizontally positioned. Make sure the orange arrow on the diskette lines up with the orange bar on the drive; otherwise, the boot procedure will fail. 2. Type the following command at the console mode prompt: »> @cnsl.com The installation software displays some system information, followed by this message: Load the RX50 labeled 'STANDALONE ULTRIX RX50 #2'. Press the Return key when ready. 3. Remove the RX50 diskette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RX50 #1, replace it with the RX50 diskette labeled ULTRIX V4.3 (V AX) STANDALONE ULTRIX RX50 #2, and press Return. The installation software displays the memory and hardware configurations. 4. Remove the RX50 diskette labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RX50 #2, replace it with the RX50 diskette labeled ULTRIX V4.3 (V AX) STANDALONE ULTRIX RX50 #3, and press Return. The installation software displays the memory and hardware configurations. 5. Remove the #3 RX50 diskette. You have completed booting your system. Continue the installation procedure with Chapter 4. 3-36 Booting the System 3.17 VAX 8600/8650 Processor To prepare the VAX 8600/8650 hardware: 1. Tum on power to the processor. 2. Set the processor power-on action switch to HALT and the rotary key switch to LOCAL. 3. Turn on power to the console terminal and all additional peripheral devices. 4. Halt the processor so that the console terminal displays the console mode prompt: »> Follow this procedure to boot the system: 1. Type the following command at the console mode prompt: »> @cnsl.com After the boot media has been read, a message similar to the following is displayed: Please remove the volume "VMS Exchange" from the console drive. Insert the first standalone system volume and enter "YES" when ready: 2. Remove the RL02 console disk currently located in the disk drive inside the processor. Mount the RL02 disk labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RL02 #1 onto the disk drive located inside the processor. Make sure the drive is online and ready for operation. Type YES to the prompt. A display similar to the following is displayed: Resuming load operation on volume "", please stand by . . . The installation software displays the memory and hardware configurations. 3. Remove the RL02 disk labeled ULTRIX V4.3 (VAX) STANDALONE ULTRIX RL02 #1. 4. Mount the RL02 console disk that you removed in step 2. Make sure the drive is online and ready for operation. You have completed booting your system. Continue the installation procedure with Chapter 4. Booting the System 3-37 3.18 VAX 8820/8830/8840 Processor Look in the configuration section of your site management guide for the following numbers for the RA60 installation device: • VAX Bus Interconnect (VAXBI) number, which is the VAXBI bus to which the controller is connected • VAXBI node number, which is the node on the VAXBI bus to which the controller is connected • Disk (dn) number, which is the unit number of the RA60 disk to which the controller is connected • For an RA60 disk connected to a Hierarchical Storage Controller (HSC), the HSC Computer Interconnect (CI) node number To prepare the VAX 8820/8830/8840 hardware: 1. Tum on power to the processor. 2. Initialize the system with the @sysini t command procedure. 3. Tum on power for the console terminal and all additional peripheral devices. 4. Halt the processor so that the console terminal displays the console mode prompt: »> 5. Load the media labeled ULTRIX AND UWS V4.3 (VAX) into the software distribution device. 6. Enter the device information you obtained from the configuration section of your site management guide. 7. Enter the boot sequence described in the section that applies to your system. 3.18.1 Booting Sequence for a System Disk Connected to a Local Controller Enter the numbers and the boot command specified in the following order: d r1 BI-number BI-node d r3 disk-number @bdara The following example shows the sequence for BI number 2, BI node I, and RA60 disk 0: »> d r1 21 »> d r3 0 »> @bdara The system then displays the boot command for you to type. You have completed booting your system. Continue the installation procedure with Chapter 4. 3-38 Booting the System 3.18.2 Booting Sequence for a System Disk Connected to an HSC Enter the numbers and the boot command specified in the following order: d r1 BI-number BI-node d r2 HSC-node-number d r3 disk-number @bcara The following example shows the sequence for BI number 3, BI node 4, HSC node 8, and RA60 disk 2: »> »> »> »> d rl 34 d r2 8 d r3 2 @bcara The system then displays the boot command for you to type. You have completed booting your system. Continue the installation procedure with Chapter 4. Booting the System 3-39 3.19 VAX 9000 Processor To prepare the VAX 9000 hardware, follow these steps: 1. Tum on power to the console terminal. 2. Set the Startup switch to Halt. 3. Set the Power switch to the On position. 4. Set the Service Processor Access switch to Local/SPU. Note that to boot the system, you will be using an editor similar to EDT to edit a file. Online editing help is available. Follow the instructions included with your TKSO tape kit for inserting the tape into the tape drive. To boot the system, follow these steps: 1. Make sure that your tape cartridge is write-protected. 2. Load the tape cartridge labeled ULTRIX V4.3 (VAX) VAX 9000 INSTL TKSO into the tape drive located inside the processor. Ensure the tape is online and ready to use. 3. Type the following command at the console mode prompt to inform the operating system that the tape labeled ULTRIX is in tape drive mua7: »> mount mua7: ultrix 4. Next, copy the following command to the userfiles directory. This command takes approximately 7-10 minutes to complete. »> copy mua7: []ultrix.ima [userfiles] S. Type the following command before removing the TKSO tape: »> dismount mua7: 6. Remove the TKSO tape from the tape drive. 7. Copy the standalone boot command procedure located in the userfiles directory to the ULTRIX boot command procedure by typing the following command: »> copy [userfiles]sabkupboo.cmd [userfiles]ultrixboo.cmd 8. Next, define ul trix. ima as the root image and then identify the disk unit information for your system. To do this, you need to edit the ul trixboo. cmd file. To invoke the editor, type the following command: »> edit [userfiles]ultrixboo.cmd The screen displays an end-of-buffer message: [EOB] If you have a video display terminal, the edi t command invokes a full-screen editor similar to EDT. If you have a hardcopy terminal, it invokes a line editor. 3-40 Booting the System Note Online help for full-screen or line editing is available at any time during the editing session. Press the PF2 key or type help at the asterisk (*) or the command prompt (:). After the last line in the comment section (noted by exclamation points (!», open up a line for editing and add the following command: DEFINE/SYSTEM SYS$ROOTIMAGE [USERFILES]ULTRIX.IMA Your file should look similar to the following: !Inputs: PI - "TRUE" for /START "FALSE" otherwise All other GRPs are clear DEFINE/SYS SYS$ROOTIMAGE [USERFILESJULTRIX.IMA Move the cursor to the last line in the section containing the DEPOSIT commands. Open up a line for editing and add the following command: DEPOSIT R5 %X8 This entry tells the system that the DEPOSIT command for register 5 is %X8. Your file should look similar to the following: EXAMINE/SYMBOL=START_ADDRESS PC DEPOSIT RO %X40 DEPOSIT R3 1 DEPOSIT R5 %X8 !Get the start address Set device type (CONSOLE) Set the disk unit number required mode for ULTRIX To end the editing session, press CtrllZ. The system will display an asterisk (*). Type ex it. The installation procedure returns you to the system prompt. 9. To initialize the hardware, type the following command: »> ilk 1O. To boot the ULTRIX software, type the following command. This will take several minutes to complete. »> b ultrix You have completed booting your system. Continue the installation procedure with Chapter 4. Booting the System 3-41 Performing the Installation 4 This chapter describes how to perform the basic and advanced installations. You must perform an installation in these situations: • When you have never installed ULTRIX or ULTRIX W orksystem Software systems. • When you have the ULTRIX or ULTRIX Worksystem Software installed, but the product version is not Version 4.2 or higher. Note If your system is ULTRIX or ULTRIX Worksystem Software Version 4.2 or higher, you can perform an upgrade instead of an installation. Continue with Chapter 5 to perform an upgrade. Whether you decide to do a basic or an advanced installation, you need to complete the tasks described in Section 4.1 through Section 4.5. Through Section 4.5, the basic and advanced installation follow similar paths by requiring you to specify a system disk, reboot the system, and specify system information. However, the information you provide for the system disk in the advanced installation may differ from that in the basic installation. After Section 4.5, the two installation procedures diverge. The basic installation uses the default file system layout and installs the mandatory subsets. The advanced installation can take one of two paths: • You can select the default disk partitions, the default file system layout, and a choice of optional subsets. • You can select customized disk partitions, a customized file system layout, and a choice of optional subsets. There are some post-installation procedures that you cannot perform if you choose the basic installation. For example, printer services are not available with the basic installation. See Table 4-1 for further information. If you plan to perform the advanced installation, before proceeding you should review Chapter 2 to ensure that you have enough disk space and that the disks' partitions are as you want them. Refer to Table 2-2 and Table 2-6 for this information. Appendix D contains an example of an advanced installation. 4.1 Choosing the Type of Installation Throughout the installation procedure, you will be prompted for information about the installation. Some prompts have a default response which is shown by brackets surrounding a letter, for example [b]. Press Return to accept the default response or enter the letter that corresponds to the option you want to choose. The first step in installing the software is choosing whether to perform a basic or advanced installation. The system displays a brief message describing the basic installation and a menu like the following: Select one of the following options: 1) BASIC Installation 2) ADVANCED Installation 3) System management Enter your choice: Type the number corresponding to the type of installation you want to perform. See Chapter 7 for further information on the system management option. After you make your selection, the prompt for the next task is displayed. Note Advanced installations are required for V AX station 3520 and 3540 systems. 4.2 Selecting the Software Distribution Device This section applies only if your system uses console boot media. The following processors use console boot media: • • • • • • • VAX-I 1/750 • • VAX 87XX VAX-I 1/780 VAX-I 1/785 VAX 8200/8250 VAX 8300/8350 VAX 86XX VAX 85XX VAX 8800 series If your system does not use console boot media, continue the installation procedure with Section 4.3. Because your system uses console boot media, you must select the device on which you will load the distribution media supplied with your kit. The system displays a table listing the possible software distribution devices for your system. The table lists the following information: Selection The selection number associated with each possible distribution device. Device Name The Digital name for each device. ULTRIXName The ULTRIX identifier for each device. Device Number The device number of each device. Controller Name The name of the peripheral controller to which the device is connected. 4-2 Performing the Installation Controller Number The controller number associated with each device. You need the controller number only if the table shows two devices of the same type with the same device number. For example, a VAX-111785 processor displays a table similar to the following: *** SOFTWARE DISTRIBUTION DEVICE SELECTION *** The 'Guide to Installing ULTRIX' explains the following table of software distribution devices and which installation media you should load on it: SOFTWARE DISTRIBUTION DEVICE TABLE Selection 1 2 Device Name RA60 TU81 ULTRIX Name ra2 tmsO Device Number 2 o Controller Name KDB50 TU81 Controller Number 4 20 To select the software distribution device, follow these steps: 1. Type the selection number corresponding to the device you want. 2. Load the BootlUpgrade media into the software distribution device you selected from the table. Make sure the device is on line. 3. After the message displays the Digital name for the device, the ULTRIX name, and the device number of your selection, the procedure asks you to confirm your choice. To confirm your choice, enter y. After you press Return, the table of system disk drives is displayed. 4.3 Selecting the Disk for the root Partition The next step in installing the software is specifying your system disk. The system disk, also referred to as the a or root partition, will contain the root file system and the swap 1 space. The procedure displays a table listing the following information: Selection The selection number associated with each possible system disk. Device Name The Digital name for each disk. ULTRIX Name The ULTRIX identifier for each disk. Device Number The device number of each disk. Controller Name The controller name associated with each disk. You need the controller number only if the table shows two disks of the same type with the same device number. Controller Number The unit number for the system disk must be in the range 0 to 254 for r a -type disks and in the range 0 to 31 for other types of disks. This disk will contain the root file system and the swap 1 space. The system displays a table similar to the one shown in the following example of a DEC station 5000 processor. This table lists the devices available for your processor. Select the device you want to contain the root file system by typing the selection Performing the Installation 4-3 number at the prompt and pressing Return. *** SYSTEM DISK SELECTION *** The 'Guide to Installing ULTRIX' explains the following table of system disk drives. Select one of the devices below to contain the root file system: SYSTEM DISK TABLE Selection Device Name RZ55 RZ56 RZ56 1 2 3 ULTRIX Name rzO rz1 rz13 Device Number o 1 5 Controller Name SCSI SCSI SCSI Controller Number o o 1 Enter your choice: 3 After you enter your selection number, a message is displayed indicating the device name and the device number. You are asked to make sure the disk drive is on line and write-enabled. Then, you are asked to confirm your choice. If you decide not to use the device you selected, enter n at the prompt and choose another device from the table. You selected RZ56, device number 13. Make sure this disk drive is on line and write-enabled (if applicable to your disk drive), then confirm your choice. Use RZ56, rz13, for your system disk? (yin) []: y If you selected the advanced installation and you have nonstandard disk partitions on the system disk, a prompt is displayed asking you to select either the default partition table or the existing partition table. The default partition table refers to the standard disk partitions for this release. The existing partition table refers to partitions that have been customized. Select one of the following partition tables to be displayed for the system disk rz13 RZ56: 1 2 Default partition table Existing partition table Enter your choice: 2 Depending on your choice, the system displays either the default partition table or the existing partition table. Then, the system asks if these are the disk partitions you want. Type y at the prompt if you want to choose the partition table displayed. Type n at the prompt if you decide you want to choose a different table. If you enter n, the system will redisplay the prompt to select either the default or existing partition table. Note If you select the existing partition table and the existing partition sizes are below the minimum sizes established for this release, your selection will be rejected. After you enter and confirm your choice, the system allocates, makes, and restores the root file system on partition a of the system disk. A message similar to the following is displayed: 4-4 Performing the Installation The installation procedure now allocates the root file system on partition 'a' of the system disk, rz13 RZ56. Making the root file system on rz13 RZ56. The installation procedure is now restoring the root file system to partition 'a' of the system disk, rz13 RZ56. 1351+0 records in 1351+0 records out 4.4 Rebooting the System After the root file system is restored to the a partition, the installation procedure prints messages telling you how to reboot your system. Follow these steps to reboot the system: 1. If the system has not halted the processor for you, halt the processor, following the instructions provided by the system. After you halt the processor, the system displays the console mode prompt. Note that on VAX workstations the console prompt may be displayed anywhere along the left side of your screen, instead of at the end of the installation messages. 2. Type the boot command at the console mode prompt, using the boot sequence provided by the system. For example, the boot command sequence provided by the installation procedure for the DECsystem 5000 is as follows: *** BOOTSTRAP COMMAND SEQUENCE *** Issue the following console commands to set your default bootpath variable and to boot your system disk: » » setenv boot "2/rz5/vrnunix -a" boot For example, at the prompt for the DECsystem 5000, enter: » setenv boot 112/rz5/vmunix -all » boot 4.5 Specifying System Information A series of prompts is displayed asking you to enter system information. Read these prompts carefully. Each prompt tells you the correct format to use. If you enter an inappropriate response, you continue to receive the prompt until you enter a valid response. The prompts ask you to provide the following information: • The system name After you enter the system name, you are asked to confirm your choice. Network installations do not ask you for a system name. • The date and time • Your time zone • Whether your area alternates between daylight savings and standard time Performing the Installation 4-5 • Your geographic area • A superuser password Choose a superuser password that other people are unlikely to guess and keep it secure. The password should be up to eight characters in length. A longer password will be truncated to eight characters. After you enter your superuser password, you are prompted to reenter it to confirm that it is correct. Note that as a security measure the password you enter is not displayed on the terminal. After you set up the superuser password, anyone who logs in with the superuser name root, must use the password you choose here. Do not use the password given in the following example: *** SPECIFY THE SUPERUSER PASSWORD *** Enter new password: faR!Kle Verify: faR!Kle At this point, the basic and advanced installation procedures diverge. If you selected the basic installation, continue with Section 4.7. If you selected the advanced installation, continue with Section 4.6. 4.6 Allocating File Systems If you selected the advanced installation, the procedure continues as follows. The system disk you selected contains the root file system on partition a. If you chose to use the default partition table, the system displays a table showing the default file system layout. The table shows the locations of the following areas on your system disk: • The root file system • The / u s r file system • The swapl space • The crash dump space The information displayed looks similar to the following: *** FILE SYSTEM DEFAULT OPTION *** The following table shows the default file system layout on RZ56, rz13: partition a b g bottom 0 32768 163840 top 32767 163839 731505 size 32768 131072 567666 overlap c c c,d,e default root swap, dump /usr If you choose the defaults, the var area will be allocated to /usr/var. A prompt is displayed asking if you want to choose the default file system layout. Do you want to choose the default file system layout? (y/n): y If you want to accept the defaults, enter y. The system will display information 4-6 Performing the Installation similar to the following. Making the new file system for /usr on /dev/rrz13g RZ56 *** SUPPORTED SOFTWARE INSTALLATION *** If you enter y at the prompt, continue with Section 4.7. If you enter n at the prompt, continue with Section 4.6.1. 4.6.1 Allocating the lusr File System If you chose not to use the default partition table, the system displays a table similar to the one shown in the following example of a DEC station 5000. This table lists the disks connected to your processor. Select the disk on which you want to allocate the /usr file system by typing the disk's selection number at the prompt. Refer to the file system worksheet in Table 2-6 for the disk name. *** /usr FILE SYSTEM ALLOCATION *** You can allocate the /usr file system to one of the disks listed in the table below. See the Guide to Installing ULTRIX for an explanation of this table: /usr FILE SYSTEM ALLOCATION TABLE Selection 1 2 3 Device Name RZ55 RZ56 RZ56 ULTRIX Name rzO rz1 rz13 Device Number o 1 5 Controller Name SCSI SCSI SCSI Controller Number o o 1 Enter your choice: 3 You selected RZ56, device number 13. Make sure this disk is on line and write-enabled (if applicable to this drive) and then confirm your choice. Use RZ56, rz13 for /usr file system? (y In) []: y After you enter your confirmation, a message is displayed indicating: • The partitions available on the disk you selected • The size in KB of each available partition • Other partitions over which each available partition extends The system instructs you to enter the letter of the partition on which you want to allocate the /usr file system. Refer to the /usr file system worksheet in Table 2-5 that you filled out for the partition. A default partition is displayed in the square brackets only if the disk is the system Performing the Installation 4-7 disk. The disk rz13 you selected from the previous table has the following partitions available, on which you can allocate the /usr file system: partition size (KB) d e f g h overlap 146265 146265 275137 283833 283834 c,g c,g,h c,h c,d,e c,e,f Type the letter of the partition on which you want to allocate the /usr file system [no default]: 9 Making the new file system for /usr on /dev/rrz13g RZ56 4.6.2 Allocating the swap1 Space The system displays a table similar to the one shown in the following example. This table lists the disks connected to your processor. Select the disk on which you want to allocate the swap 1 space. *** ALLOCATE THE SWAP1 SPACE *** You can allocate the swap1 space to one of the disks listed in the table below. See the Guide to Installing ULTRIX for an explanation of this table: SWAP1 SPACE ALLOCATION TABLE Selection 1 2 3 Device Name RZ55 RZ56 RZ56 ULTRIX Name Device Number a rzO rz1 rz13 Controller Name SCSI SCSI SCSI 1 5 Controller Number a a 1 Enter your choice: 3 You selected RZ56, device number 13. Make sure this disk is on line and write-enabled (if applicable to this drive) and then confirm your choice. Use RZ56, rz13 for swap1 space? (y In) []: y After you enter your confirmation, a message is displayed indicating: • The partitions available on the disk you selected • The size in KB of each available partition • Other partitions over which each available partition extends Refer to the file system worksheet in Table 2-6 for the disk name and partition. 4-8 Performing the Installation Note If you choose a partition that overlaps the a partition, where customized partition information resides, you will overwrite any customized partition table that describes the disk you selected and overwrite the superblock. For this reason the system does not include the a partition in the list of partitions available for the swap area. The disk rz13 you selected from the previous table has the following partitions available, on which you can allocate the swap1 space: partition size (Kbytes) overlap 65536 275137 283834 b f h c c,h c,e,f Type the letter of the partition on which you want to allocate the swap1 space [b]: b Note If you want to upgrade the system in future releases, you must allocate the swap 1 space on partition b of the system disk. 4.6.3 Allocating the swap2 Space A prompt is displayed asking if you want to allocate a second swap space. If you do not want to allocate a second swap space, enter il, and continue with Section 4.6.4. Otherwise, enter y and complete this section. *** ALLOCATE THE SWAP2 SPACE *** Do you want to allocate a second swap space? (yin) [n]: y The system displays a table similar to the one shown in the following example. This table lists the disks connected to your processor. Select the disk on which you want to allocate the swap2 space. You can allocate the swap2 space to one of the disks listed in the table below. See the Guide to Installing ULTRIX for an explanation of this table: SWAP2 SPACE ALLOCATION TABLE Selection 1 2 3 Device Name RZ55 RZ56 RZ56 ULTRIX Name rzO rzl rz13 Device Number o 1 5 Controller Name SCSI SCSI SCSI Controller Number o o 1 Performing the Installation 4-9 Enter your choice: 1 You seiected RZ55, device number O. Make sure this disk is on line and write-enabled (if applicable to this drive) and then confirm your choice. Use RZ55, rzO for swap2 space? (yin) []: y After you enter your confirmation, a message is displayed indicating: • The partitions available on the disk you selected • The size in KB of each available partition • Other partitions over which each available partition extends You are prompted to enter the letter of the partition on which you want to allocate the swap2 space. Refer to the file system worksheet in Table 2-6 for the disk name and partition. The disk rzO you selected from the previous table has the following partitions available, on which you can allocate the swap2 space: partition size (Kbytes) 73728 324520 40960 40960 122880 234408 29608 b c d e f g h overlap c a,b,d,e,f,g,h c,g c,g c,g c,d,e,f,h c,g Type the letter of the partition on which you want to allocate the swap2 space [no default]: b 4.6.4 Allocating the Crash Dump Space The system displays a table similar to the one shown in the following example. This table lists the disks connected to your processor. Select the disk on which you want to allocate the crash dump space. *** ALLOCATE THE CRASH DUMP SPACE *** You can allocate the crash dump space to one of the disks listed in the table below. See the Guide to Installing ULTRIX for an explanation of this table: CRASH DUMP SPACE ALLOCATION TABLE Selection 1 2 3 Device Name RZ55 RZ56 RZ56 4-10 Performing the Installation ULTRIX Name rzO rz1 rz13 Device Number o 1 5 Controller Name SCSI SCSI SCSI Controller Number o o 1 Enter your choice: 3 You selected RZ56, device number 13. Make sure this disk is on line and write-enabled (if applicable to this drive) and then confirm your choice. Use RZ56, rz13 for crash dump space? (yin) []: y After you enter your confinnation, a message is displayed indicating: • The partitions available on the disk you selected • The size in KB of each available partition • Other partitions over which each available partition extends You are prompted to enter the letter of the partition on which you want to allocate the crash dump space. You can allocate the crash dump space to the same partition as either swap 1 or swap2. Refer to the file system worksheet in Table 2-6 for the disk name. Note The crash dump space must be on a disk connected to the same controller as the system disk. The disk rz13 you selected from the previous table has the following partitions available, on which you can allocate the crash dump space: partition size (Kbtyes) overlap 275137 283834 65536 f h b c,h c,e,f c Type the letter of the partition on which you want to allocate the crash dump space [b]: b 4.6.5 Allocating the var Area The system displays a table similar to the one shown in the following example. This table lists the disks connected to your processor. Select the disk on which you want to allocate the var area. *** ALLOCATE THE var FILE SYSTEM *** You can allocate the var file system to one of the disks listed in the table below. See the Guide to Installing ULTRIX for an explanation of this table: var FILE SYSTEM ALLOCATION TABLE Selection 1 2 3 Device Name RZ55 RZ56 RZ56 ULTRIX Name rzO rz1 rz13 Device Number o 1 5 Controller Name SCSI SCSI SCSI Controller Number o o 1 Performing the Installation 4-11 Enter your choice: 3 You selected RZ56, device number 13. Make sure this disk is on line and write-enabled (if applicable to this drive) and then confirm your choice. Use RZ56, rz13 for var file system? (yin) []: y After you enter your confirmation, a message is displayed indicating: • The partitions available on the disk you selected • The size in KB of each available partition • Other partitions over which each available partition extends You are prompted to enter the letter of the partition on which you want to allocate the var area. You can allocate the var area either to a separate partition as a file system, or as a directory under the /usr file system. If you want to allocate the var area to the /usr file system, select the same disk and partition selected in Section 4.6.1. Refer to the file system worksheet in Table 2-6. The disk rz13 you selected from the previous table has the following partitions available, on which you can allocate the var file system: partition f h g size (Kbytes) 275137 283834 283833 overlap c,h c,e,f c,d,e Type the letter of the partition on which you want to allocate the var file system [g]: h Making the new file system for var on Idev/rrz13h RZ56 Continue with Section 4.7. 4.7 Installing ULTRIX Worksystem Software If you are installing on a machine other than a workstation, a message describing the licenses required to load ULTRIX Worksystem Software is displayed, followed by a prompt to choose whether or not to install the ULTRIX Worksystem Software. For example: This distribution media includes subsets for ULTRIX Worksystem Software (UWS). A UWS license (on a workstation) or a UWS Server License (on a timesharing machine or server) is required to install these subsets. Do you want to install ULTRIX Worksystem Software? yin []: After you respond to the prompt, continue with Section 4.8. If you are installing to a workstation, you are asked to select the type of monitor display being used. Refer to your system's hardware guide for this information. 4-12 Performing the Installation Type the selection number at the prompt. Select one of the options below that describes the enter of display being used: 1) Black and White 2) Color 3) Gray Scale Enter your choice: After you enter your choice, continue with Section 4.8. 4.8 Loading the Software Subsets Next, you can load the software subsets from the distribution media. If you are installing from a TK50 or MT9 tape, continue with Section 4.8.1. If you are installing from a CDROM, continue with Section 4.8.2. If you are installing from the network and choose the basic installation, continue with Section 4.8.3. If you are installing from the network and choose the advanced installation, continue with Section 4.8.4. 4.8.1 Installing from TK50 or MT9 Tape If you are installing from a TK50 or an MT9 tape, you are now required to change tape cartridges. The installation script prompts you with the following statement: *** SUPPORTED SOFTWARE INSTALLATION *** Remove the tape containing the BOOT/UPGRADE software and replace it with the tape containing the SUPPORTED software subsets. Remove the tape marked ULTRIX AND UWS V4.3 BOOTIUPGRADE and replace it with the tape marked ULTRIX AND UWS V4.3 SUPPORTED Volume 1. Note The tape marked ULTRIX AND UWS V4.3 BOOTIUPGRADE contains only the bootstrap sequence and the update subsets. Other tapes, marked as SUPPORTED SOFTWARE, contain the supported subsets. The installation software prompts you to make sure the distribution media containing the supported software subsets for ULTRIX is mounted and on line. If it is not, mount the media labeled SUPPORTED and prepare the device for read-only operations. The installation software displays the following prompt and message: Please make sure your installation tape is mounted and on-line. Are you ready (y/n)? After you enter y, the procedure displays the following message: positioning Tape If you are performing a basic installation, continue with Section 4.8.3. If you are performing an advanced installation, continue with Section 4.8.4. Performing the Installation 4-13 4.8.2 Installing from a COROM If you are installing from a CDROM, the device is already prepared and loaded. If you chose a basic installation continue with Section 4.8.3. If you chose an advanced installation continue with Section 4.8.4. 4.8.3 Loading Software Subsets for the Basic Installation When you choose the basic installation, the system loads the software subsets and displays copying, working, and verifying messages. For example: Base System (UDTBASE420) Copying from /dev/nrmtOh (tape) Working .... Thu May 09 17:38:02 EDT 1991 Verifying Working .... Thu May 09 17:42:22 EDT 1991 If you are doing a tape installation, some of the subsets are on a second (or more, with MT9 tapes) tape volume. When the procedure needs these subsets, the system displays the following message: Volume change. Rewinding tape ... 17:01:00 GMT 1991 Working ... Thu Jul 25 When the tape has finished rewinding, you see the following: Please remove tape volume 1 and replace it with volume 2 Remove the tape volume and replace it with the next tape volume. Continue this procedure each time a tape is rewound until all the tapes have been read. Next, the system asks if the tape is online and ready. If you enter y the installation procedure continues installing the subsets. When the system finishes installing the software subsets, it displays a message telling you that the software subsets have been installed. Continue with Section 4.9. 4.8.4 Loading Software Subsets for the Advanced Installation When you choose the advanced installation, the system displays a menu of required software subsets. *** Enter Subset Selections *** The following subsets are mandatory and will be installed automatically: The system then displays a list of the optional subsets and asks you to enter the numbers corresponding to the optional subsets you want to install. Separate multiple 4-14 Performing the Installation selections with spaces. The subsets listed below are optional: Enter your choice(s): 1 2 3 4 5 The system pauses briefly while it determines that the selected subsets will fit on the disk. Next, the system displays a list of the subsets you chose to install and asks you to verify your choice. You are installing the following subsets: Is this correct? (yin): y If you want to change your choice of subsets, enter n at the prompt; the system will again prompt you to select the optional subsets. The system loads the software subsets and displays copying, working, and verifying messages. For example: Base System (UDTBASE420) Copying from IdevlnrmtOh (tape) Working .... Thu May 09 17:38:02 EDT 1991 Verifying Working .... Thu May 09 17:42:22 EDT 1991 If you are installing from tape, some of the optional subsets are on a second (or more, with MT9 tapes) tape volume. If you selected any of these optional subsets, the system displays the following message: Volume change. Rewinding tape ... 17:01:00 GMT 1991 Working ... Thu Jul 25 When the tape is rewound, the system displays the following message: please remove tape volume 1 and replace it with volume 2 Remove the tape volume and replace it with the next tape volume. Continue this procedure each time a tape is rewound until all the tapes have been read. Next, the system asks if the tape is on line and ready. If you enter y, the installation procedure continues installing the subsets and displays a message telling you when the subsets have been installed. Continue with Section 4.9 Performing the Installation 4-15 Note For VAXstation 3520 and 3540 systems, you must choose the VS35XX XIIIDECwindows Fonts optional subset. If you are installing your software over the network and the upgrade subsets are available for this release on your server, these will appear in the subset selection menu. Be sure to select the corresponding upgrade subset for each subset you select. For example, if you want to install the Software Development Utilities subset and an upgrade exists for it, enter the selection number for the option and the selection number for the Software Development Utilities UPGRADE. 4.9 Loading the Software Subset Upgrades This release of ULTRIX and UWS contains software subset upgrades. How you install these subsets depends on your distribution media. 4.9.1 Loading Upgrades from TK50 or MT9 Tape If you are installing from a TK50 tape, the system asks you to remove the tape labeled ULTRIX AND UWS V4.3 SUPPORTED and replace it with the tape labeled ULTRIX AND UWS V4.3 BOOTIUPGRADE. The installation software has successfully installed the software subsets. You can now remove the tape containing the software subsets from the device. Please mount the tape containing the BOOT/UPGRADE subsets. Note The tape labeled ULTRIX AND UWS V4.3 BOOTIUPGRADE is the same tape that you used to boot your system. It contains both the bootstrap sequence and the upgrade subsets. Next, the system asks you to make sure your installation tape is mounted and on line and asks if you are ready. Please make sure your installation tape is mounted and on-line. Are you ready (y/n)? y After you enter y, the system displays the following message: Positioning Tape If you chose the basic installation, only the standard upgrades are installed. If you chose the advanced installation, the system displays a menu of all upgrade subsets. You are prompted to select the subsets you want to install. Select each subset and separate multiple selections with spaces. 4-16 Performing the Installation If you select the following option, only the subsets listed as mandatory are installed: None of the Above If you enter y at the prompt asking you to confirm your selection, the system loads the subsets. If you enter n, the system redisplays the menu and asks you to enter and confirm your choice of subsets. After you confirm your choice, the system installs the subsets. When the subset installation is complete, the system displays a message telling you that the software subsets have been installed. If you chose the advanced installation, continue with Section 4.10. If you chose the basic installation, continue with Section 4.11. Note If for some reason the system is unable to install the upgrade subsets, the following error message is displayed: The installation procedure was unable to install the Upgrade subsets. The system then attempts to install the upgrade subsets a second time. *** Attempting again to install the Upgrade subsets *** If the system is still unable to install the upgrade subsets, the following error message is displayed: The installation procedure failed to install the Upgrade subsets. This causes the installation procedure to stop. Contact your DIGITAL representative. 4.9.2 Loading Upgrades from COROM If you are installing from CDROM disk and there are upgrade subsets on the media that must be installed, the system displays the following message: Installing Upgrade Subsets If you chose the basic installation, only the standard upgrade subsets are installed. If you chose the advanced installation, the system displays a menu of all upgrade subsets. You are prompted to select the subsets you want to install. Select each subset and separate mUltiple selections with spaces. If you select the following option, only the subsets listed as mandatory are installed: None of the Above If you enter y at the prompt asking you to confirm your selection, the system loads the subsets. If you enter n at the prompt, the system redisplays the menu and asks you to enter and confirm your choice of subsets. Once you have confirmed your choice, the system installs the subsets. Performing the Installation 4-17 When the subset installation is complete, the system displays a message telling you that the software subsets have been installed. If you chose the advanced installation, continue with Section 4.10. If you chose the basic installation, continue with Section 4.11. Note If for some reason the system is unable to install the upgrade subsets, you will receive the following error message: The installation procedure was unable to install the Upgrade subsets The system attempts to install the upgrade subsets a second time. *** Attempting again to install the Upgrade subsets *** If the system is still unable to install the upgrade subsets, the following error message is displayed: The installation procedure failed to install the Upgrade subsets. This causes the installation procedure to stop. Contact your DIGITAL representative. 4.10 Specifying Kernel Options for the Configuration File This section applies only if you chose the advanced installation. After you install the upgrade, the system displays a table listing the kernel options for the configuration file and asks you to enter the selection number for each kernel option you want. Separate multiple selection numbers with spaces. After you enter your selection, the system displays a list of the kernel options you selected and asks you to confirm your choice. *** CONFIGURATION FILE KERNEL OPTION SELECTION *** Selection 1 2 3 4 5 6 7 8 9 10 4-18 Performing the Installation Kernel Option Local Area Transport (LAT) Bisynchronous Communication protocol (VAX only) Computer Interconnect (CI) network Diagnostic/Utilities Protocol (DUP) IS09660 File System Support (CDFS) Ethernet Packet Filter Enhanced Security Features DECnet All of the above None of the above Enter the selection number for each kernel option you want. For example, 1 3 : 1 3 5 7 8 You specified the following kernel options: Local Area Transport (LAT) Computer Interconnect (CI) network IS09660 File System Support (CDFS) Enhanced Security Features DECnet If you do not want the kernel options you selected, enter n at the prompt. The system redisplays the list of kernel options. Once you are satisfied with your choice, enter y at the prompt. Is this correct? (yin) [n]: y What is displayed next depends on whether you have hardware installed in the floating address space. If the system does not find devices in the floating address space, it issues a message like the following: * * * SYSTEM CONFIGURATION PROCEDURE * * * Configuration file complete. If the system finds devices in the floating address space, it issues a message with a list of devices similar to the following: * * * SYSTEM CONFIGURATION PROCEDURE * * * The system found these devices in the floating address space: uda2 dzO dz1 on ubaO at 160354 on ubaO at 160100 on ubaO at 160110 Configuration file complete. The system displays a prompt asking if you want to edit the configuration file. Enter at the prompt if you need to modify the configuration file. You are expected to understand the format of the configuration file and how to use the ed editor. (For more information on editing your system's configuration file, see the Guide to Configuration File Maintenance.) y Do you want to edit the configuration file? (yin) [n]: You will need to edit the configuration file in the following situations: • Your system's configuration does not conform to CSR address assignment rules. When you install ULTRIX software, the UNIBUS and Q-bus devices that reside in the floating address space are automatically sized. Therefore, the placement of devices in this space is critical to the success of your installation. If your configuration does not conform to CSR address assignment rules, you must perform an advanced installation because it allows you to edit the system configuration file built by the system. If you have questions about the accuracy of your floating address space configuration, contact your Digital Field Service representative. • You have disk controllers in the floating address space. If your system contains any disk controllers with addresses assigned in the floating address space (address space beginning with 016), the installation assumes that the controller has no devices attached to it because the installation Performing the Installation 4-19 software cannot correctly find the number of drives attached to a disk controller in floating address space. To include any drives attached to a disk controller in the floating address space, you need to edit the configuration file and manually add these drives to the file. The following example represents the relevant portion of a configuration file before and after it was edited during the installation. The system in this example has three KFQSA controllers: uqO, uq 17, and uq 18, of which uq 17 and uq 18 are in the floating address space, and each controller has one drive attached to it, unit numbers 0, 1, and 3, respectively. The software places the following information in the configuration file: controller controller disk controller controller controller controller udaO uqO raO udal uq17 uda2 uq18 at at at at at at at ubaO udaO uqO ubaO udal ubaO uda2 csr 0172150 drive 0 vector uqintr csr 0160334 vector uqintr csr 0160340 vector uqintr The configuration file does not include drives 1 and 3. To include these drives, edit the configuration file as follows: controller controller disk controller controller disk controller controller disk • udaO uqO raO udal uq17 ra1 uda2 uq18 ra2 at at at at at at at at at ubaO udaO uqO ubaO udal uq17 ubaO uda2 uq18 csr 0172150 drive 0 vector uqintr csr 0160334 drive 1 vector uqintr csr 0160340 drive 3 vector uqintr You have both a KDA50 and an RQDX controller on the Q-bus. If your system has both a KDA50 and an RQDX controller on a Q-bus, the installation procedure assumes that the drive numbers on the second controller are 0, 1,2, and 3. This may not be true for your system. You need to edit the configuration file to assign the correct drive numbers to the second controller. Note Your system's configuration file may contain lines representing unsupported devices that are commented out with a number sign (#) as the first character of the line. Do not remove the number signs at this time because the modules required for these devices are on the unsupported kit, which you have not yet installed. Once the unsupported kit is installed, remove the number signs and use the resulting configuration file to build a kernel containing the unsupported modules. The time required for system configuration varies according to processor. 4.11 Console Boot Defaults and Console Media Section 4.11.1 and Section 4.11.2 contain processor-specific information for updating console boot defaults and console media. If these sections do not apply to your processor, continue with Section 4.12. 4-20 Performing the Installation 4.11.1 Updating the Console Boot Default If you have one of the following processors, the next step in the installation procedure is to update the console boot defaults: • MicroVAX 3100 • Micro VAX 3500 • MicroVAX 3300/3400 • VAXserver 3300/3400 • VAX 6000-nnn series or VAXserver 6000-nnn series Once the system halts the processor, follow the instructions displayed on the screen. Once you have completed these instructions, you can enter the b command whenever you need to boot your system. See the Guide to System Shutdown and Startup for more information. Continue the installation procedure with Section 4.12. 4.11.2 Updating the Console Media If you have one of the following processors with the system disk connected to a Hierarchical Storage Controller (HSC), the next step in installation procedure is to update the console media: • VAX-l 11750 • VAX-l 1/780 • VAX-l 1/785 • VAX 8600/8650 • VAX 8200/8250 • VAX 8300/8350 The following system prompt is displayed: *** CONSOLE MEDIA UPDATE *** You need a blank tape, disk, or diskette, depending on the type of console media. The procedure instructs you to do the following: 1. Ensure the console media is in the drive. 2. Press Return to extract the files. 3. Remove· the console media from the drive. 4. Insert a blank piece of console media, first making sure that is write-enabled. For a TU58 tape cassette, the RECORD tab should be in the leftmost position. For an RX50 diskette, there should be no write-protect tab on the edge of the diskette. 5. Press Return. Messages similar to the following are displayed: Building console for ULTRIX. This takes several minutes Directory listing of the new console follows. Performing the Installation 4-21 6. What you do next depends on which processor you have. - For a VAX-111750, remove the TU58 tape cassette from the drive and writelock the cassette. Then, reinsert the TU58 cassette into the drive. Follow the instructions that are displayed, telling you to set the front switch labeled BOOT DEVICE to the position that boots the cassette. If your system includes a Computer Interconnect (CI), the distributed console tape labeled ULTRIX V4.2 BOOT 111, an equivalent tape, or a customized tape built for a CIIHSC system disk should remain in its drive at all times. This is necessary to load required CI microcode. - For a VAX-111780 or VAX-111785, leave the RX01 console diskette in the drive. The files on this diskette let you automatically boot the system, using the default boot commands. - For a V AX 8200/8250/8300/8350, if your system includes a Computer Interconnect (CI), the distributed console diskette labeled ULTRIX V4.2 BOOT Ill, an equivalent diskette, or a customized diskette built for a CIIHSC system disk should remain in its drive at all times. This is necessary to load required CI microcode. You must also update the Electrically Erasable Programmable Read-Only Memory (EEPROM) to specify the default boot device. Refer to the hardware guide for information. You should also run the VAX diagnostic program EBUCA. Continue the installation procedure with Section 4.12. 4.12 Completing the Installation and Rebooting the System Depending on your processor type and system disk, the software either reboots the system automatically or displays instructions on how to reboot your system. Note You can cause MicroVAX 2000 and VAXstation 2000 processors to boot automatically from a disk other than device 0 by issuing the TEST 51 command at the console prompt. Refer to the hardware documentation that comes with these processors for more information. The system displays messages similar to the following: *** SOFTWARE INSTALLATION PROCEDURE COMPLETE *** The following files were created during the installation procedure: /vmunix /genvmunix /usr/adm/install.log /usr/adm/install.FS.log /usr/adm/install.DEV.log - customized kernel generic kernel installation log file file systems log file special device log file If you are installing to a system without a graphics console, a login prompt is displayed. The login prompt indicates that your installation was successful. For 4-22 Performing the Installation example: Ultrixboot - V4.3 Sat Jul 04 06:15:25 EDT 1992 ULTRIX V4.3 System #1: Sat Jul 04 06:18:28 EDT 1992 ULTRIX V4.3 login: (mysystem) If you are installing to a workstation, a Start Session dialog box is displayed indicating that your ULTRIX W orksystem Software session manager is running. The box contains a login prompt and a password prompt. You can now log in to the superuser account by typing root at the login prompt and the superuser password specified earlier in the installation at the password prompt. See the DECwindows User's Guide for information about how to use ULTRIX Worksystem Software, including how to log in and use the Session Manager. 4.13 Post-Installation Procedures A message referring to the locations of /vmunix, / genvmunix, and the log files is included in the message-of-the-day file, / etc /motd, and will appear each time you log in to your system. If you want, you can delete these references from your /etc/motd file. See the Guide to System and Network Setup for information about the / etc /motd file. Print out the log files generated in /usr / adm during your installation. You may need information from these files for system maintenance. Each system has a twouser license as the default. If you want to increase your system's simultaneous login capacity to more than two users, you must register your Product Authorization Keys (PAKs). See the Guide to Software Licensing for information about registering PAKs. The following table lists some of the tasks you may want to perform, with the name of the utility used to perform each task. See the Guide to System and Network Setup for more information about the tasks you will need to complete after the installation to establish your system's environment. See the Security Guide for Administrators for instructions on how to set up your system for enhanced security. Note The installation procedure does not provide an area for users' files. You must do this manually after the installation of the system is complete. See the Guide to System and Network Setup for more information. Table 4-1: Post-Installation Tasks Task Utility Using the License Management Facility lrnf(8) Setting up the License Management Facility lrnfsetup(8) Performing the Installation 4-23 Table 4-1: (continued) Task Utility Adding users and setting up a users' file area adduser(8) Adding devices MAKEDEV(8) Setting up printers* Iprsetup(8) Setting up a local area network netsetup(8) Setting up a Network File System nfssetup(8) Setting up uucp* uucpsetup(8) Setting up the Yellow Pages service ypsetup(8) Setting up the BINDIHESIOD service bindsetup(8) Setting up the enhanced security features* secsetup(8) Setting up the Simple Network Management Protocol* snmpsetup(8n) Setting up the Services Order Configuration file svcsetup(8) Setting up for remote installation services* ris(8) Setting up for diskless management services* dms(8) The asterisk (*) denotes the tasks that can be performed only if you chose the advanced installation. For example, if you chose the basic installation you will not be able to set up your printer unless you install the optional subsets. Use the set 1 d utility to load the unsupported software subsets and to add and delete software subsets. Proper use of set ld will help you manage disk space. For further information about the setld(8) utility see the ULTRIX Reference Pages. 4-24 Performing the Installation Performing an Upgrade 5 You can upgrade an existing ULTRIX and ULTRIX Worksystem Software Version 4.2 or higher system to an ULTRIX and ULTRIX Worksystem Software Version 4.3 system by following the instructions in this chapter. When you upgrade an existing system, you do not have to perform a complete installation. Note You cannot use this upgrade procedure on any system running ULTRIX or ULTRIX W orksystem Software versions earlier than Version 4.2. For these earlier versions of the product, you must perform a complete installation, either a basic or advanced installation. Complete installations are described in Chapter 4. The upgrade procedure has three main functions: 1. The procedure selects, copies, and verifies new product software subsets from a distribution media to your system. 2. The procedure selects, copies, and verifies update subsets to the new product subsets from a distribution media to your system. 3. The procedure rebuilds the kernel on your system with the upgraded software to produce a new version of the system. You use the ULTRIX and UWS Supported and Boot/Upgrade distribution media to upgrade the system. There are three possible upgrade paths: • If you are upgrading a local system from TK50 or MT9 tapes, from CDROM, or from the network as a client of a Remote Installation Services (RIS) server, go to Section 5.1. • If you are upgrading a new or existing RIS area on a server, go to Section 5.2. • If you are upgrading a new or existing Diskless Management System (DMS) area on a server, go to Section 5.3. Note When you use the upgrade procedure, you must rebuild the kernel for your system. You must also edit your system configuration file when you have made customizations to it. Please preview the upgrade instructions in this chapter before you begin an upgrade. The script(l) command is not available during the upgrade process. If you want a script of the upgrade to use as a log, copy the /usr /ucb/ script utility to the / trnp directory. Then, before starting the upgrade procedure, run the script command from / trnp. For example, to run the script on the upgrade into a file you name upgrade. v43 . log, enter the following command: # /tmp/seript upgrade.v43.1og 5.1 Upgrading A Local System Depending on the load device of your processor, use one of the following distribution devices to load the software: • TK50 cartridge tape • 9-track magnetic tape • CDROM • Network (from a RIS server) The upgrade procedure makes use of the setld utility and is essentially the same for all distribution device types. If you must abort the upgrade for any reason, press Ctrl/c to abort processing and prevent changes. Then, restart the upgrade from the beginning. 5.1.1 Starting the Upgrade To start the upgrade, follow these steps: 1. Log in to your system as root. 2. Bring your system down to single-user mode. Your system must be in singleuser mode to perform the upgrade procedure. The following command brings the system down to single-user mode after a delay of five minutes: # fete/shutdown +5 "Upgrading to ULTRIX V4.3" For more information on shutting down your system, see the Guide to System Shutdown and Startup and the shutdown(8) reference page. 3. Unmount all file systems and remount all ULTRIX file systems by entering the following commands: # /ete/umount -a -f # fete/mount -a -t ufs 4. Run the / etc/update program to start the daemon that will keep your file system consistent. Enter the following command: # fete/update Refer to upda t e(8) for more information. Continue with the section that describes the upgrade for the distribution media you are using: • Section 5.1.2, for upgrading from a TK50 or MT9 • Section 5.1.3, for upgrading from a CDROM • Section 5.1.4, for upgrading from the network 5-2 Performing an Upgrade 5.1.2 Upgrading from a TK50 or MT9 If you are upgrading from tape, make sure that the tape is write-protected. For both TK50 and MT9 tapes, follow these steps: 1. Load the first volume of the media labeled Supported onto your system's software distribution device. 2. Enter the following command; replace N with the logical unit number of the device you are using: # /ete/set1d -1 /dev/nr-mtNh 3. The system issues the following prompt to be sure that your distribution device is on line: Please make sure your installation tape is mounted and on-line. Are you ready (yin) ? When you have determined that the tape is mounted and on line, answer y to the prompt. Go to Section 5.1.5. 5.1.3 Upgrading from a COROM If you are upgrading from a CDROM, follow these steps: 1. Load the CDROM onto your system's distribution device. 2. Enter the following command: replace N with the logical unit number of the device you are using: # fete/mount -r /dev/rzNe /ront 3. If your system is a RISC machine, enter the following command: # /ete/set1d -1 front/RIse/BASE If your system is a VAX machine, enter the following command: # /ete/set1d -1 front/VAX/BASE Go to Section 5.1.5. 5.1.4 Upgrading from the Network If your system is a registered client and you are upgrading from the network, enter the following command: replace server: with the name of your RIS server, followed by a colon: # /ete/set1d -l~~e~ Refer to Section 5.2 for information about setting up a RIS server. Continue with Section 5.1.5. 5.1.5 Loading the Software Subsets If you are upgrading from tape, the procedure displays a Posi tioning Tape message and begins to extract the subsets from the distribution media. If you are upgrading from CDROM or the network, the procedure does not display a message Performing an Upgrade 5-3 before it begins to extract the subsets from the server over the network. The procedure determines which subsets are mandatory for your system and lists them as mandatory subsets. The procedure then lists those subsets that are optional for your system. If there are no optional subsets listed, the procedure asks you whether you wish to continue. Follow these steps to load the supported subsets from the distribution media: 1. If there are no optional subsets listed, the procedure asks you whether you wish to continue. Enter y at the prompt and skip to Step 3, below. The procedure loads the mandatory subsets specific to your system by copying and verifying each subset. 2. If there are optional subsets listed, the procedure asks you to select from three options: All of the Above, None of the Above, and Exit without installing subsets. Enter the number that represents the None of the Above option. The procedure loads the mandatory subsets specific to your system by copying and verifying each subset. 3. After it loads the subsets, the procedure may display the following message: Required kernel is not available. When this message appears, you will eventually follow the instructions in Section 5.1.8 to complete the upgrade by rebuilding your system's kernel when there is not a kernel available. Otherwise, you will eventually follow the instructions in Section 5.1.7 to complete the upgrade by rebuilding your system's kernel using an available kernel. Next, however, you must apply updates to any subsets just loaded. Continue with Section 5.1.6. Note If at a later time you decide to install any of the optional subsets, be sure to install the corresponding update subsets, if they exist, for the subsets you install. For example, if you later install subset UDTACCT430, be sure to also install the update subset UDTACCT431. 5.1.6 Loading the Software Subset Updates Next, you must load the software subsets that update the subsets just loaded. How you load the software subset updates depends on whether your distribution media is tape, CDROM, or the network. 5.1.6.1 Updating from a TK50 or MT9 If your distribution media is tape, follow these instructions to load the software subset updates. 1. Load the first volume of the media labeled ULTRIX and UWS BOOTIUPGRADE onto your system's software distribution device. 2. Enter the following command, replacing N with the actual logical unit number of 5-4 Performing an Upgrade the device you are using: # /etc/set1d -1 /dev/nr.mtNh 3. The system prompts you to be sure that your distribution device is on line, as follows: Please make sure your installation tape is mounted and on-line. Are you ready (yin) ? When you have determined that the tape is mounted and on line, enter y to the prompt. You are done loading the update subsets when the procedure returns to the superuser prompt. Then, you can continue with the instructions about rebuilding the kernel. Go to Section 5.1.7 to complete the upgrade by rebuilding your system's kernel when the required kernel is available. Go to Section 5.1.8 to complete the upgrade by rebuilding your system's kernel when the required kernel is not available. 5.1.6.2 Updating from COROM If your distribution media is CDROM, follow these instructions to load the software subset updates. If your system is a RISC machine, enter the following command: # /etc/set1d -1 /mnt/RISC/BASE_UPGRADE If your system is a VAX machine, enter the following command: # /etc/set1d -1 /mnt/VAX/BASE_UPGRADE Unmount the disk by entering the following command: # /etc/umount /mnt Remove the distribution media. Then, continue with the instructions about rebuilding the kernel. Go to Section 5.1.7 to complete the upgrade by rebuilding your system's kernel when the required kernel is available. Go to Section 5.1.8 to complete the upgrade by rebuilding your system's kernel when the required kernel is not available. 5.1.6.3 Updating from the Network If your distribution media is the network, the updates were automatically loaded. The procedure is done when it returns the superuser prompt. Go to Section 5.1.7 to complete the upgrade by rebuilding your system's kernel when the required kernel is available. Go to Section 5.1.8 to complete the upgrade by rebuilding your system's kernel when the required kernel is not available. Performing an Upgrade 5-5 5.1.7 Rebuilding a Kernel when the Required Kernel Is Available To rebuild a kernel on a system when the required kernel is available, take the following steps: 1. Use the doconfig command with the -c option to rebuild your kernel. Replace HOSTNAME in the following command with the name of your system typed in all capital letters: # /ete/doeonfig -e HOSTNAME The - c option specifies that the new kernel be built using the configuration file that already exists in the / sys / conf /vax directory for VAX processors or the / sys / conf /mips directory for RISe processors. 2. Note that the doconf ig command allows you to edit the configuration file. The following prompt appears immediately after you invoke the doconfig command with the - c option: Do you want to edit the configuration file (y/n) [n]? Only a few configurations require that you edit the configuration file at this point. Thus, in most cases, you can enter no at this prompt. The doconf ig program then displays the following message as it begins to rebuild your kernel: *** PERFORMING SYSTEM CONFIGURATION *** When the doconf ig command finishes executing, it reports the location of a newly built VAX kernel as follows: The new kernel is /sys/VAx/HOSTNAME/vrnunix It reports the location of a newly built RISe kernel as follows: The new kernel is /sys/MIPS/HOSTNAME/vrnunix When the doconf ig program completes, it returns you to the superuser prompt. 3. Move the new VAX kernel to root by entering the following command: # mv /sys/VAX/HOSTNAME/vmunix /vmunix Or, move the new RISe kernel to root by entering the following command: # mv /sys/MIPS/HOSTNAME/vmunix /vmunix 4. The generic kernel, / genvrnunix was loaded from the software distribution during the upgrade. Now, copy it to root by entering the following command: # ep /usr/genvmunix /genvmunix 5. To complete the upgrade and activate the new kernel, reboot the system by entering the following command: # fete/reboot When the reboot command returns you to the superuser prompt, the upgrade is complete. 5-6 Performing an Upgrade 5.1.8 Rebuilding a Kernel when the Required Kernel Is Not Available To rebuild a kernel on a system when the required kernel is not available, take the following steps: 1. Copy genvrnunix to vrnunix by entering the following command: # ep /usr/genvmunix /vmunix 2. Reboot your system by entering the following command: # fete/shutdown -r now "reboot with V4.3 genvmunix" 3. When your system comes up to multiuser mode, log in as root and bring your system to single-user mode by entering the following command: # fete/shutdown now "switching to single-user" 4. Unmount all file systems and remount all UFS file systems by entering the following command: # /ete/umount -a -f # fete/mount -a -t ufs 5. If you have customized your system's configuration file, enter the following command to make a copy of your system's configuration file: # ep /sys/eonf/mips/HOSTNANfE /sys/eonf/mips/HOSTNANfE.V4.2 Replace the HOSTNAME in the example with the name of your system. Note Customizations of the configuration file include local changes to its global, options, and pseudodevice definitions. You can restore the customizations in two ways: - During step 8, as the doconf ig program is running, enter yes when you are asked if you want to edit the newly created configuration file. The doconf ig program places you in the ed editor and you can add the necessary customizations. - During step 8, as the doconfig program is running, enter no when you are asked if you want to edit the newly created configuration file. After the doconf ig program finishes, use the text editor of your choice to enter the necessary customizations in the new configuration file, and then rebuild your kernel using the doconf ig -c command. For more information on using the doconf ig command with the -c option, see the doconfig(8) reference page. 6. Invoke the doconfig command with no options, as follows: # doeonfig While the system is running with a generic kernel, the doconfig program places the proper configuration entries in your system's configuration file and makes any special device files that may be required, with the exception of local configuration customizations. 7. The doconfig program is menu-driven and first asks you to supply your system's name, then tells you that a system with that name exists, and asks you Performing an Upgrade 5-7 whether you want to replace the existing system. Enter y to indicate you do want to replace the system. For example: A system with that name exists. Replace it (y/n) [n]: y The program next asks you for the date and time and the time zone for your system. 8. The doconfig program then asks you if you want to edit the configuration file. Enter no at the prompt, unless you wish at this time to customize the new configuration file. If you want to customize now, enter y at the prompt and the doconf ig program will place you into an editing session. After you exit from the editing session, the doconf ig program resumes. 9. When the doconf ig program finishes, it prints out informational messages like the following, listing the path to the new kernel and to the log of device special files that it created in the / dev directory. For example, building on a system named SAMSA: *** PERFORMING SYSTEM CONFIGURATION *** working working working Thu Aug Thu Aug Thu Aug 1 09:11:45 EDT 1991 1 09:13:45 EDT 1991 1 09:15:46 EDT 1991 *** DEVICE SPECIAL FILE CREATION *** working ..... Thu Aug 1 09:16:35 EDT 1991 A log file listing Special Device Files is located in /dev/MAKEDEV.log The new kernel is /sys/MIPS/SAMSA/vrnunix 10. Move /vrnunix to / genvrnunix by entering the following command: # mv /vmunix /genvmunix 11. Move the new kernel created by the doconf ig program to the root partition. For example: # mv /sys/MIPS/SAMSA/vmunix /vmunix Note If you are running BINDlHesiod, edit the / etc/rc .local file and add the BIND extension to the hostname entry, because doconfig overwrites the existing hostname entry with the name of your system without its BIND extension. 12. You may now enable your windowing system by running the script that updates the / et c / tty s file. Enter the following command: # /ete/server_seps 13. Reboot your system to bring in the new kernel by entering the following 5-8 Performing an Upgrade command: # shutdown -r now" boot with V4.3" The upgrade procedure is complete. 5.2 Upgrading a Remote Installation Services Area The following sections describe the steps you must follow to upgrade a Remote Installation Services (RIS) area on a server. To create a new RIS area on your RIS server, refer to the Guide to Sharing Software on a Local Area Network. You can upgrade an existing RIS area only on Version 4.3 servers. To upgrade a RIS area, follow these steps: 1. Log in to the server system as root. 2. Run the / etc / r is utility. Select the Delete Software menu item. 3. Select the RIS area to be upgraded from the menu. 4. Select the appropriate client architecture (VAX or RISe) from the menu. S. If your current system is Version 4.2A, delete the current ULTRIX Supported Product and ULTRIX BOOTIUPGRADE products from the selected RIS area by selecting their product numbers from the menu. If your current system is Version 4.2, delete the current ULTRIX Supported Product and MANDATORY UPGRADE products from the selected RIS area by choosing their product numbers from the menu. 6. Install the Version 4.3 product into the RIS area. The instructions for this part of the upgrade are the same as for installing products into an existing RIS area. Refer to the Guide to Sharing Software on a Local Area Network for these instructions. You are required to repeat this step twice. First, to install the Supported volumes, then to install the BootlUpgrade volume. The procedure is complete when the the / etc/ris utility displays the following message: Finished Extracting Subsets from Distribution Media 7. Use the RIS Modify option to modify the product for each registered client. Be sure to choose both the Supported Products and the Boot Upgrade options when modifing each client. 8. When the RIS main menu reappears, choose the exit option to return to the superuser prompt. 5.3 Upgrading a Diskless Management System Area The following section describes how to perform the upgrade on a server's Diskless Management System (DMS) area. The process consists of installing the product into the server's DMS area. Whether you can upgrade a DMS area currently serving clients depends on the version number of the clients' operating system and the version number of the server's operating system: Performing an Upgrade 5-9 • If your server is running ULTRIX and UWS Version 4.3, you can upgrade Version 4.2 (VAX and RISC) and Version 4.2A (RISC) registered client areas to Version 4.3. • If your server is running ULTRIX and UWS Version 4.2 (VAX or RISC) or Version 4.2A (RISC), you can upgrade Version 4.2 (V AX) and Version 4.2A (RISC) registered client areas to Version 4.3. • If your server is running ULTRIX and UWS Version 4.2 (VAX or RISC) or Version 4.2A (RISC), you cannot upgrade Version 4.2 (RISC) registered client areas to Version 4.3. Instead, you must first remove any Version 4.2 (RISC) clients, perform the upgrade procedure, and then reregister the clients. If your server supports multiple diskless areas, you must repeat the upgrade process for each area. Note Use the correct media to upgrade the product in your diskless areas. The upgrade will fail unless you use RISC media for an area serving RISC clients and use VAX media for an area serving VAX clients. Perform the following steps to upgrade an existing diskless area on a server: 1. Shut down all registered diskless clients. 2. Back up the diskless environments. 3. Load the first volume of the Supported media onto your software distribution device, if you have not done so already. If you are installing the product from CDROM, use the mount command as follows; replace N with the logical unit number of the device you are using: # /etc/mount -r /dev/rzNc /ront 4. Invoke the dms utility: # /etc/dms 5. Choose the Install Software option from the Diskless Management Services menu. 6. The system presents you with two software installation options. Choose the option Add software to Existing Area from the Install Software menu. 7. The system asks you into which existing diskless environment you want to install software, and lists your options. Select the appropriate environment. 8. The system prompts you to enter the device special file name or mount point of the distribution media. Your responses depend on which distribution media you use, tape or CDROM. If you are installing from a TK50 tape or MT9 tape, the command is the same for both VAX and RISC environments. Enter the following command, replacing N 5-10 Performing an Upgrade with the logical unit number of the device you are using: /dev/rmtNh Make sure that the installed nledia is write-protected. Note When installing from tape, the procedure determines which tapes must be loaded and prompts you to mount the appropriate volumes. For example, you could receive a message like the following: Please remove tape Vol 4 and replace it with Vol 2 Follow the instructions the procedure supplies. If you are installing from CDROM to an area serving RISC clients, enter the following command: /mnt/RIse/BASE If you are installing from CDROM to an area serving VAX clients, enter the following command: /mnt/VAX/BASE 9. If there are clients already registered, the procedure displays the following question: The product software will automatically be propagated to every registered client. Is that alright? (yin): Enter y at the prompt to propagate the product to registered clients. If you enter n at the prompt, you will have to upgrade clients later. The system lists mandatory and optional subsets from the Supported media and installs them. The system copies and verifies each subset you selected. 10. If your installation media is TK50 or MT9, remove the Supported tape from the drive and load the Boot/Upgrade tape in the drive. 11. Choose the Install Software option from the Diskless Management Services menu. 12. The system presents you with two software installation options. Choose the option, Add software to Existing Area from the Install Software menu. 13. The system asks you into which existing diskless environment you want to install software, and lists your options. Select the appropriate environment. 14. The system prompts you to enter the device special file name or mount point of the distribution media. Your responses depend on which distribution media you use, tape or CDROM. If you are installing from a TK50 tape or MT9 tape, the command is the same for both VAX and RISC environments. Enter the following command, replacing N Performing an Upgrade 5-11 with the actual logical unit number of the device you are using: /dev/rmtNh Make sure that the installed media is write-protected. If you are installing from CDROM to an area serving RISC clients, enter the following command: /mnt/RISC/BASE_UPGRADE If you are installing from CDROM to an area serving V AX clients, enter the following command: /mnt/VAX/BASE_UPGRADE 15. If there are clients already registered, the procedure displays the following question: The product software will automatically be propagated to every registered client. Is that alright? (yin): Enter y at the prompt to propagate the product to registered clients. If you enter n at the prompt, you will have to upgrade clients later. The system lists mandatory and optional subsets from the BootlUpgrade media and installs them. The system copies and verifies each subset you selected. 16. If your upgrade media is a CDROM, use the following command to unmount the disk: # /etc/umount /ront If your installation media is TK50 or MT9 tape, remove it from the drive. Your upgrade is complete. You may now reboot each new client, unless you have modified the area of previously-registered clients. In that event, you must run the DMS Rebuild Kernel option for each client. Then you can reboot the clients. 5-12 Performing an Upgrade Adding and Deleting Software Subsets 6 The set1d utility is used to install and manage software. You can save disk space with the set1d command by specifying and loading only the software subsets that you need. This chapter describes how to use the set1d utility. You must have superuser privileges to modify the system software using set 1d. The set 1d utility has several command line syntaxes to list, add, and delete software subsets. Although the command lines differ, the set1d command lines use certain command arguments as follows: • The di r argument specifies the destination of the subset. Specify this argument if you are loading the software to a file hierarchy that starts somewhere other than at root (/). • The optional subs e t argument specifies the name of the subset. • The 1 oca t i on argument specifies the device special file or mount point containing the media from which the subset or product is to be transferred. If you specify a di r argument, it must precede the command function. If you specify a subset or a location argument, it must follow the command function. For detailed information on the set 1 d command, its functions, and the command line syntax, see set1d(8) in the ULTRIX Reference Pages. 6.1 Listing Software Subsets To display the status of all subsets known to the system, specify the set 1d command with the -i (inventory) function. The format is as follows: setld [-0 din -i [subset] For example, to display a list of subsets, enter the following: # setld -i To display the files included in a particular subset, for example, UDTUUCP430, enter the following: # setld -i UDTUUCP430 6.2 Adding Subsets To add a subset to your system, use the set 1d command with the -1 (load) function, the location argument and the subset argument. The format is as follows: setld [-0 dir] -I < location> subset [ subset. .. ] The following examples show how to add subsets to your system from tape and from a file server. 6.2.1 Adding Subsets from Tape To add or reinstall a subset on the / mn t directory of your system from a kit residing at tape drive / dev / rmt lh, enter a command like the following: # set1d -D /mnt -1 6.2.2 /dev/rmtlh UDTUUCP430 Adding Subsets from a File Server To add or reinstall subsets from a file server, enter a command like the following, substituting the name of the file server for the server in the example: # set1d -1 server: 6.3 Deleting Subsets To delete a subset from your system, use the set ld command with the -d function and the subset argument. The syntax is as follows: setld [-0 dir] -d subset [ subset. .. ] For example, to delete the UDTUUCP400 subset from your system, enter the following: # set1d -d UDTUUCP400 6-2 Adding and Deleting Software Subsets Working in the Standalone ULTRIX Environment 7 The standalone ULTRIX environment is a memory-resident environment that is used to initiate ULTRIX installations. The primary purpose of the standalone ULTRIX environment is to support the initial phases of an installation, which include selecting the distribution and system devices, as well as restoring the root file system image to the target system disk. Throughout the installation process, full ULTRIX device drivers are used. The standalone ULTRIX environment also supports limited system management activities. These activities include: • Restoring a damaged root file system • Checking the consistency of the root file system • Restoring the boot block image • Performing disk maintenance operations The standalone ULTRIX environment provides commands that assist in recovering from root file system corruption and help perform general file system and disk maintenance tasks. It is a limited environment that does not perform like a full ULTRIX operating system environment. You should perform system management activities in the standalone ULTRIX environment only if you have extensive ULTRIX or UNIX operating system experience. This chapter explains how to invoke the standalone ULTRIX environment, identifies some of its commonly used capabilities, and describes how to extend the standalone ULTRIX environment so that additional commands can be used. 7.1 Invoking the Standalone ULTRIX Environment The media and the commands that you use to invoke the standalone ULTRIX environment are dependent on the type of processor that you are using. These media and commands are identified and described in Chapter 3 of this manual. As part of the installation, the system displays the following menu of options: Select one of the following options: 1} BASIC Installation 2) ADVANCED Installation 3) System management Enter your choice: Choose the third item, System Management, to invoke the standalone ULTRIX environment. The system responds by placing the system in single-user mode and by displaying the superuser ( #) shell prompt. 7.2 Standalone ULTRIX Environment Capabilities The standalone ULTRIX environment enables you to perform several system management activities. In some cases, you have to use system primitives instead of the more advanced system commands. For example, to make a new file system, you would use the mkfs command instead of the newfs command. Note At boot time, the system does not configure controllers assigned floating CSR addresses. Only peripheral devices connected to controllers that have been assigned fixed CSR addresses are accessible. If you want access to special device files, you have to create them using the command. You can use the standalone system to perform the following tasks: MAKEDEV • Edit a file using the ed editor • Repair corrupted file systems with the fsck command • Create new file systems with the mk f s command • Restore the boot block with the dd command • Restore file systems with the restore command • Modify partition tables with the cbpt command • Mount other disks and file systems with the mount command The Guide to Backup and Restore gives an example of how to restore the root file system using the standalone ULTRIX environment after a catastrophic event has occurred. 7.3 Extending the Standalone ULTRIX Environment If you find that the commands and utilities provided by the standalone ULTRIX environment do not completely meet your needs, you can extend the environment to include access to other commands. To extend the environment, perform the following steps: 1. Make the device special files for the device that contains the target commands. To do this, change directories as follows: # cd Idev After changing directories, use the following syntax to create the special device files: MAKEDEV device The following example shows the command for making a device special file for rzOa. # MAKEDEV rzOa 2. Mount the device. For example, to mount the r z 0 a device on the / mn t file 7-2 Working in the Standalone ULTRIX Environment system, use the following format: # fete/mount /dev/rzOa /mnt This enables you to access any of the commands or files on that device. To see what commands and files are available, enter the following command: # Is /mnt The system responds by displaying the contents of I mn t . If there are directories that you want to include in your search path, reset and export the path environment variable. For example, to add Imnt Ibin to your path, enter the following command: # PATH = "$PATH:/mnt/bin"; export PATH To exit the standalone environment and halt the processor, enter the following command: # fete/halt To exit the standalone environment and return to the menu, press CtrllD. Working in the Standalone ULTRIX Environment 7-3 Rise Supported Software Subsets A Table A-I briefly describes each supported software subset for RISe processors and lists the names of any other subsets or kernel configuration file options related to its operation. Table A-1: RiSe Supported Subset Descriptions and Dependencies Subset Name Contents UDTACCT430 Accounting Software Optional Programs and data files needed to perform system accounting. This subset contains log files that grow automatically. It is intended for users familiar with ULTRIX system administration. UDTAFM430 Adobe Font Metric Files Optional Font metrics (character bounding box, width, name, ligature, kerning, and font properties) for PostScript outline fonts used by text formatting applications in PostScript output devices. Dependencies UDTBASE430 Base System Required Fundamental utilities and data files for the ULTRIX operating system. Base System includes the C compiler and linker, the editors, library and data files needed for POSIX environment, and all of the general-purpose programs. This subset cannot be removed. UDTBIN430 Required Kernel Configuration Files Utility programs and binary files required to configure ULTRIX kernels. This subset can be deleted after installation. Required to install layered prod~cts that reqmre th~ kernel to be rebmlt. UDTCDABASE430 CDA Base System Optional Runtime components for CDA. Required for: UDWMAIL430 Required for all subsets Subset Name Contents UDTCDAPGMR430 CDA Software Dev Libraries Optional Programming libraries for CDA Dependencies UDTCOMM430 Communications Utilities Optional Utilities for several types of serial communications with other systems, including tip, ftp, and telnet. UDTDCMT430 Doc. Preparation for Ref. Pages Required for: Tools to format manage and display UDTMAN430 reference pages: The n;o f f formatter and UDTMANPGRM430 required macros. UDWMAN430 UDWMANPGMR430 Optional UDTDCMTEXT430 Other Doc. Preparation Software Optional Additional nroff macro packages, bibiography tools, and ro f f tools. UDTDL430 Diskless Environment Support Optional Software for a diskless environment. This subset is required only for diskless management services. UDTEXAMPLES430 Programming Examples Optional Programming examples for: dbx, dl i, ncs, device drivers, and others. UDTEXER430 System Exerciser Package Optional Programs that help in diagnosing problems with your hardware and peripheral devices. UDTINET430 TCPIIP Networking Utilities Required Programs and data used to implement Internet networking on your ULTRIX system. Requires: UDTINET430 Required for: UDTUUCP430 Requires: UDTDCMT430 Requires: UDTPGMR430 Required for: UDTCOMM430 UDTNFS430 UDTUMAIL430 Kernel configuration: options INET A-2 RiSe Supported Software Subsets Subset Name Contents Dependencies UDTINTLPGMR430 Internationalization Dev. Env. Optional Source for internationalization languages. UDTINTLRT430 Internationalization Runtime Env. Optional Internationalization languages for set locale and internationalization tools. UDTKERB430 Kerberos Network Authentication Optional Programs and data used to implement Kerberos network authentication on your ULTRIX system. UDTMAN430 Ref. Pages for Sys. Admin. & Users Optional Online reference pages for Sections 1,4, 5, 6,7, and 8 of the ULTRIX Reference Pages. UDTMANPGMR430 Reference Pages for Programmers Optional Online reference pages for Sections 2 and 3 of the ULTRIX Reference Pages. UDTMH430 The RAND Mail Handler Optional Programs that constitute the RAND Corporation MH mail reader interface. UDTMOP430 Maintenance Operations Protocol Optional Software necessary to use your system as a boot server for LAT, DMS, or RIS. UDTNFS430 Network File System Utilities Required Programs and data files you need to share file systems over the network. This subset contains the files used to implement the Yellow Pages facility. UDTPGMR430 Software Development Utilities Optional Libraries and utilities useful for software development. These include the libraries for linking programs to be analyzed with the dbx debugger, the 1 in t program verifier, and the lex and yacc parser packages. Requires: UDTDCMT430 Requires: UDTDCMT430 Required for: UDWMAIL430 Requires: UDTUMAIL430 Kernel configuration: options DLI pseudodevice dli Requires: UDTINET430 Kernel configuration: options NFS options RPC Required for: UDTINTL430 UDTRPCDEV430 Rise Supported Software Subsets A-3 A-4 Subset Name Contents UDTPREST0430 Prestoserve (Legato) Optional Utililties for monitoring and administering Prestoserve. UDTPRINT430 Printer Support Environment Optional Printer commands such as lpr, lpq, and lpd, utilities, configuration files, filters, and PostScript printer support. UDTRPCDEV430 RPC Development Environment Optional Programs and data that implement the Remote Procedure Call (RPC) development environment. UDTRPCRT430 RPC Runtime Environment Optional Programs and data that implement the Remote Procedure Call (RPC) run-time environment. This subset is optional. UDTSCCS430 Source Code Control System Optional Programs that make up the UNIX Source Code Control System, which provides a regulation mechanism for large software projects. UDTSEC430 Enhanced Security Features Optional Programs and data that provide enhanced security features. UDTSMSCAMP430 Sys. Config. Mgmt. Program (SCAMP) Optional This is a menu-driven program for basic system administration. Rise Supported Software Subsets Dependencies Requires: UDTPGMR430 Kernel configuration: options AUDIT options SYS_TPATH pseudodevice audit Subset Name Contents Dependencies UDTUMAIL430 Extended (Berkeley) Mailer Required Programs and data that implement the BSD sendrnail facility. Required for: UDTMH430 UDTUUCP430 UNIX-to-UNIX Copy Facility Optional Programs and data files needed to let your system participate in a network of machines using the UNIX UUCP facility to transmit files over serial communications lines. UDWDECW430 Additional DECwindows Applications Optional Additional XIIIDECwindows client applications such as Calendar and PostScript Previewer. UDWFONT430 XIIIDECwindows 75dpi Fonts Required for Worksystems Fonts for XIIIDECwindows. UDWFONT15430 XIIIDECwindows 100dpi Fonts Required for DEC system 5000 Model 200 with 2-D and 3-D graphics Workstation font files for systems using either the VR160 IS-inch monitor or higher resolution graphics. UDWFONTSTR430 XIIIDECwindows PEX Fonts Required for DECsystem 5000 Model 200 with 3-D graphics XIIIDECwindows fonts for 3-D graphics cards. UDWMAIL430 DECwindows Mail Application Optional DECwindows mail application for dxmail. UDWMAN430 UWS Reference Pages Optional Online UWS reference pages for Sections 1, 4, 5, 6, 7, and 8. Requires: UDTINET430 Requires: UDTCOMM430 Requires: UDTBASE430 Requires: UDTBASE430 Requires: UDTBASE430 Requires: UDTMH430 UDTCDABASE430 Requires: UDTDCMT430 Rise Supported Software Subsets A-5 Subset Name Contents Dependencies UDWMANPGMR430 UWS Ref. Pages for Programmers Optional Online UWS reference pages for Sections 2 and 3. Requires: UDTDCMT430 UDWSER430 Server Optional Server for XIIIDECwindows. UDWSYSMGNT430 System Management Tools Optional XIIIDECwindows system management programs. UDWTPV024425 The Personal Visualizer Optional Wavefront, Inc. The Personal Visulalizer UDWTPVMAN425 Personal Visualizer Ref. Pages Optional Reference pages for The Personal Visulalizer. UDWWSTSER430 Server Optional Server for XllRR PXG 3D graphics. UDWXl1430 XIIIDECwindows User Environment Required for W orksystems X Window System client programs. UDWXDEV430 W orksystem Development Software Optional Library and data files needed to produce X Window System client applications. Includes example programs demonstrating how to get started. UDWXTXSER430 Server Optional Server for True Color Graphics. A-6 RiSe Supported Software Subsets Requires: UDTBASE430 Requires: UDTBASE430 Requires: UDTBASE430 VAX Supported Software Subsets B Table B-1 briefly describes each supported software subset for VAX processors and lists the names of any other subsets or kernel configuration file options related to each subset. Table B-1: VAX Supported Software Subset Descriptions and Dependencies Subset Name Contents ULTACCT430 Accounting Software Optional Programs and data files needed to perform system accounting. This subset contains log files that grow automatically. It is intended for users familiar with ULTRIX system administration. Dependencies ULTAFM430 Adobe Font Metric Files Optional Font metrics (character bounding box, width, name, ligature, kerning, and font properties) for PostScript outline fonts used by text formatting applications in PostScript output devices. ULTBASE430 Base System Required Fundamental utilities and data files for the ULTRIX operating system. Base System includes the C compiler and linker, the editors, library and data files needed for POSIX environment, and all of the general-purpose programs. This subset cannot be removed. ULTBIN430 Required Kernel Configuration Files Utility programs and binary files required to configure ULTRIX kernels. This subset can be deleted after installation. Required to install layered prod~cts that reqUIre th~ kernel to be rebUIlt. ULTCDABASE430 CDA Base System Optional Runtime components for CDA. Required for: UWSMAIL430 Required for all subsets Subset Name Contents ULTCDAPGMR430 CDA Software Dev Libraries Optional Programming libraries for CDA ULTBSC430 Bisynchronous Communications Optional Kernel configuration: Programs needed to use the 3780 and 2780 options BSC emulation features provided with your pseudodevice ULTRIX system. bsc ULTCOMM430 Communications Utilities Optional Utilities for several types of serial communications with other systems, including tip, ftp, and telnet. ULTDCMT430 Optional Dependencies Required for: ULTUUCP430 Requires: ULTINET430 Required for: Doc. Preparation for Ref. Pages ULTMAN430 Tools to format, manage, and display ULTMANPGMR430 reference pages. The nro f f formatter and UWSMAN430 required macros. UWSMANPGMR430 ULTDCMTEXT430 Doc. Preparation Extensions Optional Additional nro f f macro packages, bibiography tools, and ro f f tools. ULTDL430 Diskless Support Environment Optional Software for a diskless environment. This subset is required only for diskless management services. ULTEXAMPLES430 Programming Examples Optional Programming examples for: dbx, dli, nes, device drivers, and others. ULTEXER430 System Exerciser Package Optional Programs that help in diagnosing problems with your hardware and peripheral devices. ULTINET430 TCPIIP Networking Utilities Required Programs and data used to implement Internet networking on your ULTRIX system. Requires: ULTDCMT430 Requires: ULTPGMR430 Required for: ULTCOMM430 ULTNFS430 ULTUMAIL430 Kernel configuration: options INET 8-2 VAX Supported Software Subsets Subset Name Contents Dependencies ULTINTLPGMR430 Internationalization Dev. Env. Optional Source for internationalization languages. ULTINTLRT430 Internationalization Runtime Env. Optional Internationalization languages for set locale and internationalization tools. ULTKERB430 Kerberos Network Authentication Optional Programs and data used to implement Kerberos network authentication on your ULTRIX system. ULTMAN430 Optional Ref. Pages for Sys. Admin. & Users Requires: Online reference pages for Sections 1,4, 5, ULTDCMT430 6,7, and 8 of the ULTRIX Reference Pages. ULTMANPGMR430 Reference Pages for Programmers Optional Requires: Online reference pages for Sections 2 and 3 ULTDCMT430 of the ULTRIX Reference Pages. ULTMH430 The RAND Mail Handler Optional Programs that constitute the RAND Corporation MH mail reader interface. Required for: UWSMAIL430 Requires: ULTUMAIL430 VAX Supported Software Subsets B-3 Subset Name Contents Dependencies ULTMOP430 Maintenance Operations Protocol Optional Software necessary to use your system as a boot server for LAT, DMS, or RIS. Kernel configuration: options DLI pseudodevice dli ULTNFS430 Network File System Utilities Required Programs and data files you need to share file systems over the network. This subset contains the files used to implement the Yellow Pages facility. ULTPASCAL430 Pascal Optional PASCAL language compiler and associated libraries and tools. ULTPGMR430 Software Development Utilities Optional Libraries and utilities useful for software development. These include the libraries for linking programs to be analyzed with the dbx debugger, the 1 in t program verifier, and the lex and yacc parser packages. ULTPREST0430 Prestoserve (Legato) Optional Utilities for monitoring and administering Prestoserve. ULTPRINT430 Printer Support Environment Optional Printer commands such as lpr, lpq, and lpd, utilities, configuration files, filters, and PostScript printer support. ULTRPCDEV430 RPC Development Environment Optional Programs and data that implement the Remote Procedure Call (RPC) development environment. ULTRPCRT430 RPC Runtime Environment Optional Programs and data that implement the Remote Procedure Call (RPC) run-time environment. 8-4 VAX Supported Software Subsets Requires: ULTINET430 Kernel configuration: options NFS options RPC Required for: ULTINTL430 ULTRPCDEV430 Requires: ULTPGMR430 Subset Name Contents Dependencies ULTSCCS430 Source Code Control System Optional Programs that make up the UNIX Source Code Control System, which provides a regulation mechanism for large software projects. ULTSEC430 Enhanced Security Features Optional Programs and data that provide enhanced security features. ULTSMSCAMP430 Sys. Config. Mgmt. Program (SCAMP) Optional This is a menu-driven program for basic system administration. ULTUMAIL430 Extended (Berkeley) Mailer Required Programs and data that implement the BSD sendmail facility. ULTUUCP430 UNIX-to-UNIX Copy Facility Optional Programs and data files needed to let your system participate in a network of machines using the UNIX UUCP facility to transmit files over serial communications lines. ULTVAXC430 V AX C Development Package Optional VAX C language compiler and associated libraries and tools. UWSDECW430 Additional DEC windows Applications Optional Additional XIIIDECwindows client applications such as Calendar and the PostScript Previewer. UWSFONT430 XIIIDECwindows 75dpi Fonts Required for Worksystems Fonts for XIIIDECwindows. UWSFONT15430 XIIIDECwindows 100dpi Fonts Optional Workstation font files for systems using either the VR160 15-inch monitor or higher resolution graphics. Kernel configuration: options AUDIT options SYS_TPATH pseudodevice audit Required for: ULTMH430 Requires: ULTINET430 Requires: ULTCOMM430 Requires: ULTBASE430 Requires: ULTBASE430 Requires: ULTBASE430 VAX Supported Software Subsets 8-5 Subset Name Contents Dependencies UWS3DFONT430 VS35XX XIIIDECwindows Fonts Required for VAXstation 3520/3540 XIIIDECwindows fonts for VAXstation 3520/3540 processors. Requires: ULTBASE430 UWSMAIL430 DECwindows Mail Application Optional DECwindows mail application for dxmail. UWSMAN430 UWS Reference Pages Optional Online UWS reference pages for Sections 1, 4, 5, 6, 7, and 8. UWSMANPGMR430 UWS Ref. Pages for Programmers Optional Online UWS reference pages for Sections 2 and 3. UWSSER430 XIIIDECwindows Servers Required for Worksystems XIIIDECwindows server support. UWSSYSMGNT System Management Tools Optional XIIIDECwindows system management programs. UWSXl1430 XIIIDECwindows User Environment Required for Worksystems X Window System client programs. UWSXDEV430 Worksystem Development Software Optional Library and data files needed to produce X Window System client applications. Includes example programs demonstrating how to get started. 8-6 VAX Supported Software Subsets Requires: ULTMH430 ULTCDABASE430 Requires: ULTDCMT430 Requires: ULTDCMT430 Requires: ULTBASE430 Requires: ULTBASE430 Unsupported Software Subsets C Table C-l briefly describes each software subset available on the ULTRIX unsupported kit. The "UDX" prefix indicates RISe software subsets. The "ULX" prefix indicates VAX software subsets. You can use the set 1 d command to install some or all of the unsupported software subsets included with your ULTRIX system. See setid(8) for more information. The asterisk (*) denotes user-contributed software. Table C-1: Unsupported Software Subset Descriptions and Dependencies Subset Name Contents ULXAPL430* APL Development Package Dependencies APL language interpreter and associated utilities. ULXBASE430* , Base Extension UDXBASE430* Programs and data files that can be useful in some environments. These include obsolete boot programs, drivers for unsupported devices, the traff package with fonts, and miscellaneous software. ULXBIB430* , Bibliographic Utilities UDXBIB430* Programs and data useful in maintaining bibliographic information. ULXCOURIER430* , Remote Procedure Call Compiler UDXCOURIER430* Modules for producing software using the COURIER remote procedure call protocoL ULXCPM430* CP/M 8in Diskette Utility Utilities for reading and writing 8-inch diskettes used with the CP/M operating system. Requires: ULTDCMT430 or UDTDCMT430 Subset Name Contents ULXDCMT430, Document Preparation Software UDXDCMT430 Optional Additional documentation preparation utilities and fonts ULXDOC430, Supplementary Documentation UDXDOC430 Online copies of Supplementary Documentation. ULXEDIT430* , GNU Emacs UDXEDIT430* The public-domain GNU Emacs editor and edit-macro files. ULXF77430 Unsupported Fortran Utilities Utilities for developing programs using the UNIX f 77 dialect of FORTRAN. ULXGAMES430* , Games and Diversions UDXGAMES430* Programs used for entertainment. ULXHYPER430* Hyperchannel Utilities The Hyperchannel driver and associated daemons and utilities. ULXICON430* ICON (Language) Development Package Translator and linker for the ICON programming language. ULXINGRES430 University INGRES QUEL DBMS (database management system). ULXINET430 TCP/IP Networking Util Extension UDXINET430 Optional Networking utilities: traceroute, slip. ULXLEARN430, Computer-Aided System Tutor UDXLEARN430 Software for the 1 earn program, which provides lessons in aspects of the computing environment. This subset is useful for persons new to the UNIX environment. C-2 Unsupported Software Subsets Dependencies Requires: ULTDCMT430 or UDTDCMT430 Dependencies Subset Name Contents ULXLISP430 Franz Lisp Development Package Programs that make up the Franz Lisp program development environment, including interpreter, libraries, and compiler. ULXMAN430, Unsupported Online Manuals UDXMAN430 Online reference pages for programs found in the Base Extension subset. ULXMOD2430, Modula-2 Development Package Requires: UDTDCMT430 or ULTDCMT430 Modula-2 compiler and libraries. ULXNEWS430, USENET News Interface Software UDXNEWS430 Software needed to participate in the USENET news network. ULXNOTES430, Notesfiles Package UDXNOTES430 Software that lets you establish notesfiles on your ULTRIX system. ULXRCS430, Revision Control System UDXRCS430 Programs that make up a package similar to the SCCS facility provided with the supported software subsets. ULXSHELLS430, Aux. Command Line Interpreters UDXSHELLS430 The "distributed" shell and a version of the C shell that features command completion. Requires: ULTCOMM430 and ULTUUCP430, or UDTCOMM430 and UDTUUCP43° Unsupported Software Subsets C-3 Subset Name Contents ULXSPMS430 Software Project Management System Dependencies A package useful for managing large software development efforts. ULXTERM430, UDXTERM430 Additional Terminal Drivers Optional Additional terrninfo files and terminal drivers ULXTOOLS430* , Misc. User-Contributed Utilities UDXTOOLS430* Small utilities contributed by the user community. ULXUNEXAMP430, Unsupported DECwindows Examples UDXUNEXAMP430 DECwindows programming examples. ULXUNFONTS430 Unsupported MIT fonts UDXUNFONTS430 MIT fonts ULXUNMAN430, Unsupported XII Reference Pages UDXUNMAN430 Online reference pages for unsupported XII R4 features that are in the UDXUNMIT430 and ULXUNMIT430 subsets. ULXUNMIT430 Unsupported XII R4 Components UDXUNMIT430 Programs and fonts for the X Window System protocol level 11, Release 4. Contains applications such as xt errn, xload, and xedit. ULXVARIAN430 Raster Plotter Package Software used to typeset documents on the VARIAN typesetter. C-4 Unsupported Software Subsets Requires: ULTDCMT430 or UDTDCMT430 Sample Advanced Installation Procedure D The following is a sample log of an advanced installation performed on a DEC station 5000 Model 200. What the installation software displays depends on the type of system you have and the type of media you are using, but the installation procedure for all systems and media is similar. 0.1 Sample Advanced Installation Procedure. *** STANDALONE ULTRIX ENVIRONMENT *** If you select the BASIC Installation option from the list that follows, the installation software creates file systems on default partitions on your system disk and loads the mandatory ULTRIX software subsets. If you require additional installation choices, select the ADVANCED Installation option. Select one of the following options: 1) BASIC Installation 2) ADVANCED Installation 3) System management Enter your choice: 2 *** SYSTEM DISK SELECTION *** The 'Guide to Installing ULTRIX' explains the following table of system disk drives. Select one of the devices below to contain the root file system: SYSTEM DISK TABLE Selection 1 2 3 4 Device Name RZ56 RZ56 RZ56 RZ56 ULTRIX Name rzO rz1 rz2 rz3 Device Number o 1 2 3 Controller Name SCSI SCSI SCSI SCSI Controller Number o o o o Enter your choice: 1 You selected RZ56, device number O. Make sure this disk drive is on line and write-enabled (if applicable to your disk drive), then confirm your choice. Use RZ56, rzO, for your system disk? (yin) []: y The installation procedure now allocates the root file system on partition 'a' of the system disk, rzO RZ56. Making the root file system on rzO RZ56. The installation procedure is now restoring the root file system to partition 'a' of the system disk, rzO RZ56. *** BOOTSTRAP COMMAND SEQUENCE *** Issue the following console commands to set your default bootpath variable and to boot your system disk: » » setenv boot "5/rzO/vmunix -a" boot *** SYSTEM NAME SPECIFICATION *** Select the name of your system using alphanumeric characters. The first character must be a letter. For example, tinker. Enter your system name: laforge You selected laforge as the name of your system. Is this correct? (yin) [y]: y *** DATE AND TIME SPECIFICATION *** The current date and time should be specified using the following format: yymmddhhmm Use two digits for year (yy), month (mm), day (dd), hour (hh), and minute (mm). Enter the time in 24-hour format. For example, 11:30 p.m. on May 3, 1991 would be entered as: 9105032330 Enter the date and time: 9206161439 *** TIME ZONE SELECTION *** Select the time zone for your area, using the options listed in the table below. You can also enter the number of hours (-12 to 12) in time east of Greenwich. Selection Time Zone e c m p g Eastern Central Mountain Pacific Greenwich Enter your choice: e Does your area alternate between Daylight Savings and Standard time? (yin) [y]: y Select your geographic area for Daylight Savings Time, using the options in the table below. Selection Geographic Area u a e c w USA Australia Eastern Europe Central Europe Western Europe Enter your choice [u): u 0-2 Sample Advanced Installation Procedure The current date and time is Tue Jun 16 14:39:23 EDT 1992 *** FILE SYSTEM DEFAULT OPTION *** The following table shows the default file system layout on RZ56, rzO: partition a b g bottom 0 32768 163840 top 32767 163839 731505 overlap c c c,d,e size 32768 131072 567666 default root swap, dump /usr If you choose the defaults, the var area will be allocated to /usr/var. Do you want to choose the default file system layout? (y/n) : y Making the new file system for /usr on /dev/rrzOg RZ56 Select one of the options below that describes the type of display being used: 1) Black and White 2) Color 3) Gray Scale Enter your choice: 2 *** SUPPORTED SOFTWARE INSTALLATION *** Remove the tape containing the BOOT/UPGRADE software and replace it with the tape containing the SUPPORTED software subsets. Please make sure your installation tape is mounted and on-line. Are you ready (y/n)? y Positioning Tape *** Enter Subset Selections *** The following subsets are mandatory and will be installed automatically: * Base System * Kernel Config Files * TCP/IP Networking Utilities * Network File System utilities * Extended (Berkeley) Mailer * B&W, Color, or PX Server * X11R4 PXG Server * Xll/DECwindows User Environment * Xll/DECwindows 75dpi Fonts * Xll/DECwindows 100dpi Fonts * X11/DECwindows PEX Fonts The 1) 3) 5) 7) 9) 11) 13) 15) 17) 19) 21) 23) 25) 27) 29) 31) 33) subsets listed below are optional: Truecolor Server RAND Mail Handler Communications Utilities Maintenance Operations Protocol Kerberos Network Authentication Prestoserve Utilities Doc. Preparation for Ref. Pages Adobe Font Metric Files Source Code Control System Internationalization Dev. Env. CDA Software Dev Libraries RPC Development Environment Reference Pages for Programers Additional DECwindows Applications Worksystem Development Environment UWS Runtime Reference Pages Wavefront Personal Visualizer 2) 4) 6) 8) 10) 12) 14) 16) 18) 20) 22) 24) 26) 28) 30) 32) 34) Printer Support Environment Sys. Config. Mgmt. Program (SCAMP) Unix-to-Unix Copy Facility Accounting Software Enhanced Security Features System Exerciser Package Doc. Preparation Extensions Software Development Utilities Internationalization Runtime Env. CDA Base System RPC Runtime Environment Ref. Pages for Sys. Admin. & Users programming Examples DECwindows Mail Application System Management Tools UWS Development Reference Pages Personal Visualizer Manual Page 35) All of the Above 36) None of the Above 37) Exit without installing subsets Sample Advanced Installation Procedure 0-3 Enter your choice(s): 35 You are installing the following subsets: Base System TCP/IP Networking Utilities Extended (Berkeley) Mailer X11R4 PXG Server X11/DECwindows 75dpi Fonts X11/DECwindows PEX Fonts Printer Support Environment Sys. Config. Mgmt. Program (SCAMP) Unix-to-Unix Copy Facility Accounting Software Enhanced Security Features System Exerciser Package Doc. Preparation Extensions Software Development Utilities Internationalization Runtime Env. CDA Base System RPC Runtime Environment Ref. Pages for Sys. Admin. & Users Programming Examples DECwindows Mail Application System Management Tools UWS Development Reference Pages Personal Visualizer Manual Page Kernel Config Files Network File System Utilities B&W, Color, or PX Server X11/DECwindows User Environment X11/DECwindows 100dpi Fonts Truecolor Server RAND Mail Handler Communications Utilities Maintenance Operations Protocol Kerberos Network Authentication Prestoserve Utilities Doc. Preparation for Ref. Pages Adobe Font Metric Files Source Code Control System Internationalization Dev. Env. CDA Software Dev Libraries RPC Development Environment Reference Pages for Programers Additional DECwindows Applications Worksystem Development Environment UWS Runtime Reference Pages Wavefront Personal Visualizer Is this correct? (y/n): y Base System (UDTBASE430) Copying from /dev/nrmtOh Working .... Tue Jun 16 Working .... Tue Jun 16 Working .... Tue Jun 16 Verifying Working .... Tue Jun 16 (tape) 14:52:45 EDT 1992 14:54:58 EDT 1992 14:57:14 EDT 1992 14:58:40 EDT 1992 Kernel Config Files (UDTBIN430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 14:59:31 Working .... Tue Jun 16 15:01:48 Working .... Tue Jun 16 15:03:53 Working .... Tue Jun 16 15:06:02 Verifying Working .... Tue Jun 16 15:07:11 EDT EDT EDT EDT 1992 1992 1992 1992 EDT 1992 TCP/IP Networking Utilities (UDTINET430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 15:08:19 EDT 1992 Verifying Network File System Utilities (UDTNFS430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 15:10:04 EDT 1992 Verifying Extended (Berkeley) Mailer (UDTUMAIL430) Copying from /dev/nrmtOh (tape) Verifying B&W, Color, or PX Server (UDWSER430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 15:11:37 EDT 1992 Working .... Tue Jun 16 15:12:16 EDT 1992 Verifying X11R4 PXG Server (UDWWSTSER430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 15:13:52 EDT 1992 Working .... Tue Jun 16 15:14:26 EDT 1992 Verifying D-4 Sample Advanced Installation Procedure X11/DECwindows User Environment (UDWXl1430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 15:15:30 EDT 1992 Verifying X11/DECwindows 75dpi Fonts (UDWFONT430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 15:17:20 EDT 1992 Verifying X11/DECwindows 100dpi Fonts (UDWFONT15430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 15:18:28 EDT 1992 Verifying X11/DECwindows PEX Fonts (UDWFONTSTR430) Copying from /dev/nrmtOh (tape) Verifying Truecolor Server (UDWXTXSER430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 15:20:13 EDT 1992 Working .... Tue Jun 16 15:21:34 EDT 1992 Verifying Printer Support Environment (UDTPRINT430) Copying from /dev/nrmtOh (tape) Volume change. Rewinding tape ... Working .... Tue Jun 16 15:22:25 EDT 1992 Please remove tape volume 1 and replace it with volume 2. Are you ready (y/n)? y Working .... Tue Jun 16 16:13:26 EDT 1992 Verifying RAND Mail Handler (UDTMH430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:14:26 EDT 1992 Verifying Sys. Config. Mgmt. Program (SCAMP) Copying from /dev/nrmtOh (tape) Verifying (UDTSMSCAMP430) Communications utilities (UDTCOMM430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:17:06 EDT 1992 Verifying Unix-to-Unix Copy Facility (UDTUUCP430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:17:45 EDT 1992 Verifying Maintenance Operations Protocol (UDTMOP430) Copying from /dev/nrmtOh (tape) Verifying Accounting Software (UDTACCT430) Copying from /dev/nrmtOh (tape) Verifying Kerberos Network Authentication (UDTKERB430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:19:38 EDT 1992 Verifying Enhanced Security Features (UDTSEC430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:20:36 EDT 1992 Verifying Sample Advanced Installation Procedure 0-5 Prestoserve Utilities (UDTPREST0430) Copying from /dev/nrmtOh (tape) Verifying System Exerciser Package (UDTEXER430) Copying from /dev/nrmtOh (tape) Verifying Doc. Preparation for Ref. Pages (UDTDCMT430) Copying from /dev/nrmtOh (tape) Verifying Doc. Preparation Extensions (UDTDCMTEXT430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:22:53 EDT 1992 Verifying Adobe Font Metric Files (UDTAFM430) Copying from /dev/nrmtOh (tape) Verifying Software Development Utilities (UDTPGMR430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:24:09 EDT 1992 Verifying Source Code Control System (UDTSCCS430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:26:07 EDT 1992 Verifying Internationalization Runtime Env. Copying from /dev/nrmtOh (tape) Verifying (UDTINTLRT430) Internationalization Dev. Env. (UDTINTLPGMR430) Copying from /dev/nrmtOh (tape) Verifying CDA Base System (UDTCDABASE430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:27:53 EDT 1992 Verifying CDA Software Dev Libraries (UDTCDAPGMR430) Copying from /dev/nrmtOh (tape) Verifying RPC Runtime Environment (UDTRPCRT430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:29:48 EDT 1992 Verifying RPC Development Environment (UDTRPCDEV430) Copying from /dev/nrmtOh (tape) Verifying Ref. Pages for Sys. Admin. & Users (UDTMAN430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:31:08 EDT 1992 Verifying Reference Pages for Programers (UDTMANPGMR430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:32:54 EDT 1992 Verifying Programming Examples (UDTEXAMPLES430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:34:35 EDT 1992 Verifying 0-6 Sample Advanced Installation Procedure Additional DECwindows Applications (UDWDECW430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:35:17 EDT 1992 Working .... Tue Jun 16 16:37:18 EDT 1992 Verifying DECwindows Mail Application (UDWMAIL430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:38:01 EDT 1992 Verifying Worksystem Development Environment (UDWXDEV430) Copying from /dev/nrmtOh (tape) Working ... . Tue Jun 16 16:38:53 EDT 1992 Verifying System Management Tools (UDWSYSMGNT430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:41:25 EDT 1992 Verifying UWS Runtime Reference Pages (UDWMAN430) Copying from /dev/nrmtOh (tape) Verifying UWS Development Reference Pages (UDWMANPGMR430) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:43:09 EDT 1992 Verifying Wavefront Personal Visualizer (UDWTPV024425) Copying from /dev/nrmtOh (tape) Working .... Tue Jun 16 16:44:40 EDT 1992 Working .... Tue Jun 16 16:46:46 EDT 1992 Verifying Working .... Tue Jun 16 16:48:36 EDT 1992 Personal Visualizer Manual Page (UDWTPVMAN425) Copying from /dev/nrmtOh (tape) Verifying Installation of Wavefront Personal Visualizer V2.4 for ULTRIX on Tue Jun 16 16:50:15 EDT 1992 Wavefront Personal Visualizer V2.4 for ULTRIX Installation Procedure succeeded Rewinding Tape .. . Working .... Tue Jun 16 16:50:53 EDT 1992 The installation software has successfully installed the software subsets. You can now remove the tape containing the software subsets from the device. Please mount the tape containing the BOOT/UPGRADE subsets. Please make sure your installation tape Are you ready (y/n)? y Positioning Tape Working .... Tue Jun 16 16:54:35 EDT Working .... Tue Jun 16 16:56:35 EDT Working .... Tue Jun 16 16:58:36 EDT Working .... Tue Jun 16 17:00:37 EDT is mounted and on-line. 1992 1992 1992 1992 The following subsets will be installed: * Generic Kernel Do you wish to continue? (y/n): y Generic Kernel (UDTGENVMUNIX431) Copying from /dev/nrmtOh (tape) Sample Advanced Installation Procedure 0-7 Working .... Tue Jun 16 17:04:01 EDT 1992 Verifying Rewinding Tape .. . Working .... Tue Jun 16 17:05:12 EDT 1992 The installation procedure has successfully installed the Upgrade subsets *** CONFIGURATION FILE KERNEL OPTION SELECTION *** Selection 1 2 3 4 5 6 7 8 9 10 Kernel Option Local Area Transport (LAT) Bisynchronous Communication protocol (VAX only) Computer Interconnect (CI) network Diagnostic/Utilities Protocol (DUP) IS09660 File System Support (CDFS) Ethernet Packet Filter Enhanced Security Features DECnet All of the above None of the above Enter the selection number for each kernel option you want. For example, 1 3: 1 2 3 4 5 6 8 You specified the following kernel options: Local Area Transport (LAT) Computer Interconnect (CI) network Diagnostic/Utilities Protocol (DUP) IS09660 File System Support (CDFS) Ethernet Packet Filter DECnet Is this correct? (y/n) [nl: y *** SYSTEM CONFIGURATION PROCEDURE *** Configuration file complete. Do you want to edit the configuration file? (y/n) [nl: n *** PERFORMING SYSTEM CONFIGURATION *** working Tue Jun 16 17:07:40 EDT 1992 working Tue Jun 16 17:09:40 EDT 1992 working Tue Jun 16 17:11:41 EDT 1992 *** DEVICE SPECIAL FILE CREATION *** working ..... Tue Jun 16 17:12:47 EDT 1992 *** SOFTWARE INSTALLATION PROCEDURE COMPLETE *** The following files were created during the installation procedure: /vmunix /genvmunix /usr/adm/install.log /usr/adm/install.FS.log /usr/adm/install.DEV.log 0-8 Sample Advanced Installation Procedure - customized kernel generic kernel installation log file file systems log file special device log file Index A console boot default advanced installation defined, 1-3 updating, 4-21 console media updating, 4-21 example, D-l selecting menu option, 4-1 console terminal defined, 1--4 crash dump B defined, 2-5 var area and, 2-7 backing up the system, 1-6 basic installation crash dump space allocating, 4-10 defined, 1-2 disk connection and controller, 2-5n selecting menu option, 4-1 examples of partial, 2-6t BIND server requirements, 2-5 files to back up, 1-7 Bisynchronous Communication Protocol, 2-12t CSR addresses, 1--4 block, 2-1 boot default o updating, 4-21 booting over the network, 3-1 byte, 2-1 data disk defined, 1--4 date specifying, 4-5 c daylight savings/standard time status CDROM optical disc cartridge, 1-1 DECnet,2-12t chpt command, 2-1 DECstation 2100 processor specifying, 4-5 querying disk partition layout, 2-3e client registering as, 3-1 Computer Interconnect (CI), 2-12t configuration file adding kernel options, 4-18 editing during installation, 4-19 planning the file entries, 2-11 booting procedure for, 3--4 DECstation 3100 processor booting procedure for, 3--4 DECstation 31008 processor booting procedure for, 3--4 DECstation 5000, Model 100 processor booting procedure for, 3-6 DECstation 5000, Model 200 processor booting procedure for, 3-6 DECsystem 3100 processor booting procedure for, 3--4 DEC system 5000, Model 200 processor F Factory Installed Software, 1-1 file system booting procedure for, 3-6 specifying default partitions, 4-6 DEC system 5100 processor specifying existing partitions, 4-5 booting procedure for, 3-9 DECsystem 5400 processor worksheet, 2-11 t floating address space booting procedure for, 3-11 hardware devices and, 4-19 DEC system 5500 processor booting procedure for, 3-12 DECsystem 5810 processor booting procedure for, 3-15 G geographic area DECsystem 5820 processor booting procedure for, 3-15 DECsystem 5830 processor specifying, 4-5 Gray Scale Monitor specifying, 4-12 booting procedure for, 3-15 DECsystem 5840 processor booting procedure for, 3-15 dfcommand H hardware required for installation, 1--4 measuring space in KB, 2-1 DiagnosticlUtilities Protocol (DUP), 2-12t disk configuration worksheets, 2-3t disk partition layout choosing, 4-3 IS09660 File System Support, 2-12t deciding whether to accept the default, 2-10 modifying,2-3e K specifying default, 4-6 kernel options, 2-12t disk quotas setting, 2-9 Diskless Management Services booting over the network, 3-1 disks identifying supported system, 2-2 specifying during installation, 4-18 kilobyte, 2-1 L Local Area Transport (LAT), 2-12t E M enhanced security features, 2-12t mandatory subsets error logger file space requirements for, 2-7 Ethernet packet filter, 2-12t space allocation for, 2-9 megabyte, 2-1 MicroVAX 2000 processor booting procedure for, 3-17 MicroVAX 3100 processor booting procedure for, 3-19 updating console boot default, 4-21 Index-2 MicroVAX 3300 processor booting procedure for, 3-22 RIse supported software subsets, A-I to A-6 RISe unsupported software subsets, C-l to C--4 updating console boot default, 4-21 MicroVAX 3400 processor booting procedure for, 3-22 updating console boot default, 4-21 MicroVAX 3500 processor s savecore utility saving a core dump with, 2-7 booting procedure for, 3-24 sector, 2-1 updating console boot default, 4-21 setld command MicroVAX 3600 processor booting procedure for, 3-24 MicroVAX 3800 processor booting procedure for, 3-24 MicroVAX 3900 processor booting procedure for, 3-24 MicroVAX II processor booting procedure for, 3-24 MT9 magnetic tape kit, 1-1 adding software subsets, 6-1 deleting software subsets, 6-2 listing software subsets, 6-1 single-system disk unsupported,2-2n software distribution device description, 1--4 selecting, 4-2 software distribution kit components of, 1-5 software subset N adding, 6-1 network booting over, 3-1 software subsets adding, 6-1 adding from file server, 6-2 o adding from tape, 6-2 defined,2-9 optional subsets space allocation for, 2-9 deleting, 6-2 listing, 6-1 RISC supported, A-I to A-6 p RISC unsupported, C-l to C--4 post-installation procedures, 4-23 post-installation tasks, 4-23t processor booting procedure for, 3-6 processor-specific boot instructions locations of, 3-1 t selecting, 4-14 VAX supported, B-1 to B-6 VAX unsupported, C-l to C--4 standalone ULTRIX environment, 7-1 to 7-3 defined, 1--4 subsets adding, 6-1 deleting, 6-2 R installing, 4-14 rebooting procedure, 4-5 Remote Installation Services, 1-2 booting over the network, 3-1 RIS directory listing status, 6-1 superuser password logging in with, 4-22 specifying, 4-5, 4-6 space requirements for, 2-8 Index-3 swap space lusr file system (cont.) crash dump space and, 2-4 space requirements for, 2-10 defined, 2-4 worksheet, 2-10t partition a, 2-4n swapl space v allocating, 4-8 swap2 space allocating, 4-9 sysinit command initializing the system with, 3-36 system accounting space requirements for, 2-7 system disk selecting, 4-3 system disk drive defined, 1-4 system disk partition changing the disk partition table, 4-4 system disks, 2-2t system information specifying, 4-5 system management menu option, 4-1 system name specifying, 4-5 system time specifying, 4-5 system upgrade, 1-2 var area, 2-10 allocating, 4-11 defined, 2-6 determining size, 2-6 space requirements for, 2-6 var area worksheet completing, 2-8t VAX 6000-nnn series processor booting procedure for systems with a CIBCA-AA controller, 3-32 booting procedure for systems with a CIBCA-AB controller, 3-33 booting procedure for systems without a CIBCAAA controller, 3-32 updating console boot default, 4-21 VAX 6210 processor booting procedure for, 3-32 VAX 6220 processor booting procedure for, 3-32 VAX 6230 processor booting procedure for, 3-32 VAX 6240 processor booting procedure for, 3-32 T VAX 6310 processor tape cartridge kit, 1-1 time zone specifying, 4-5 booting procedure for, 3-32 VAX 6320 processor booting procedure for, 3-32 VAX 6330 processor u booting procedure for, 3-32 VAX 6340 processor ULTRIX name of distribution device, 4-2 ULTRIX subsets, 4-14 upgrade installation defined, 1-2 upgrade procedure, 5-1 user area, 2-9 lusr file system allocating, 4-7 Index-4 booting procedure for, 3-32 VAX 6350 processor booting procedure for, 3-32 VAX 6360 processor booting procedure for, 3-32 VAX 8200 processor booting procedure for, 3-34 updating console media, 4-21 VAX 8250 processor VAX-ll/785 processor booting procedure for, 3-34 booting procedure for, 3-30 updating console media, 4-21 updating console media, 4-21 VAX 8300 processor booting procedure for, 3-34 updating console media, 4-21 VAX 8350 processor booting procedure for, 3-34 updating console media, 4-21 VAX 8500 processor booting procedure for, 3-36 VAX 8530 processor booting procedure for, 3-36 VAX 8550 processor booting procedure for, 3-36 VAX 8600 processor booting procedure for, 3-37 updating console media, 4-21 VAX 8650 processor booting procedure for, 3-37 updating console media, 4-21 VAX 8700 processor booting procedure for, 3-36 VAX 8800 processor booting procedure for, 3-36 VAX 8810 processor booting procedure for, 3-36 VAX 8820 processor booting procedure for, 3-38 VAX 8830 processor booting procedure for, 3-38 VAX 8840 processor booting procedure for, 3-38 VAX 9000 processor booting procedure for, 3-40 VAX supported software subsets, B-1 to B-6 VAX unsupported software subsets, C-l to C-4 VAX-ll/750 processor booting procedure for, 3-28 updating console media, 4-21 VAX-ll/780 processor booting procedure for, 3-30 VAXserver 100 processor booting procedure for, 3-24 VAXserver 2000 processor booting procedure for, 3-17 VAXserver 3100 processor booting procedure for, 3-19 VAXserver 3300 processor booting procedure for, 3-22 updating console boot default, 4-21 VAXserver 3400 processor booting procedure for, 3-22 updating console boot default, 4-21 VAXserver 3500 processor booting procedure for, 3-24 VAXserver 3600 processor booting procedure for, 3-24 VAXserver 3800 processor booting procedure for, 3-24 VAXserver 3900 processor booting procedure for, 3-24 VAXserver 6000-nnn series processor booting procedure for, 3-32 VAXstation 2000 processor booting procedure for, 3-17 VAXstation 3100 processor booting procedure for, 3-19 VAXstation 3200 processor booting procedure for, 3-24 VAXstation 3500 processor booting procedure for, 3-24 VAXstation 3520 processor booting procedure for, 3-26 VAXstation 3540 processor booting procedure for, 3-26 VAXstation II processor booting procedure for, 3-24 VAXstation IIIGPX processor booting procedure for, 3-24 vrnunix, 2-11 updating console media, 4-21 Index-5 w worksheets disk configuration, 2-3t file system, 2-11 t lusr file system, 2-IOt var,2-8t y Yellow Pages server files to back up, 1-7 Index-6 How to Order Additional Documentation Technical Support If you need help deciding which documentation best meets your needs, call 800-343-4040 before placing your electronic, telephone, or direct mail order. Electronic Orders To place an order at the Electronic Store, dial 800-234-1998 using a 1200- or 2400-bps modem from anywhere in the USA, Canada, or Puerto Rico. If you need assistance using the Electronic Store, call 800-DIGITAL (800-344-4825). Telephone and Direct Mail Orders Your Location Call Contact Continental USA, Alaska, or Hawaii 800-DIGITAL Digital Equipment Corporation P.o. Box CS2008 Nashua, New Hampshire 03061 Puerto Rico 809-754-7575 Local Digital subsidiary Canada 800-267-6215 Digital Equipment of Canada Attn: DECdirect Operations KA0212 P.O. Box 13000 100 Herzberg Road Kanata, Ontario, Canada K2K 2A6 International Local Digital subsidiary or approved distributor Internala SSB Order Processing - WMOlE15 or Software Supply Business Digital Equipment Corporation Westminster, Massachusetts 01473 a For internal orders, you must submit an Internal Software Order Form (EN-OI740-07). Reader's Comments ULTRIX Guide to Installing ULTRIX AA-PBLOE-TE Please use this postage-paid form to comment on this manual. If you require a written reply to a software problem and are eligible to receive one under Software Performance Report (SPR) service, submit your comments on an SPR form. Thank you for your assistance. Please rate this manual: Accuracy (software works as manual says) Completeness (enough information) Clarity (easy to understand) Organization (structure of subject matter) Figures (useful) Examples (useful) Index (ability to find topic) Page layout (easy to find information) Excellent D D D D D D D D Good Fair Poor D D D D D D D D D D D D D D D D D D D D D D D D What would you like to see more/less of? What do you like best about this manual? What do you like least about this manual? Please list errors you have found in this manual: Page Description Additional comments or suggestions to improve this manual: What version of the software described by this manual are you using? _ _ _ _ _ __ NamefTitle Dept. Company _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ___ Date _ _ _ _ __ Mailing Address _ _ _ _ _ _ _ _ _ _ _ _ _ Email Phone _ _ _ _ _ _ __ · - - - - -. Do Not Tear - Fold Here and Tape !lmlDlllM NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST-CLASS MAIL PERMIT NO. 33 MAYNARD MA POSTAGE WILL BE PAID BY ADDRESSEE DIGITAL EQUIPMENT CORPORATION OPEN SOFTWARE PUBLICATIONS MANAGER ZK03-3N32 110 SPIT BROOK ROAD NASHUA NH 03062-9987 1111 III did 11111111111 III 111111111 dII 1111111111111 .------. Do Not Tear- Fold Here ._--------------------------------------------------------------, Cut Along Dotted Line
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Create Date : 2010:06:11 14:21:43-08:00 Modify Date : 2010:06:11 15:24:56-07:00 Metadata Date : 2010:06:11 15:24:56-07:00 Producer : Adobe Acrobat 9.32 Paper Capture Plug-in Format : application/pdf Document ID : uuid:15e1f8f7-6022-42ef-a407-46c5a124a873 Instance ID : uuid:73c6dec3-cc30-41c8-adec-9c2667055d77 Page Layout : SinglePage Page Mode : UseNone Page Count : 153EXIF Metadata provided by EXIF.tools