ABB Water Master User Manual
User Manual: ABB WaterMaster User Manual
Open the PDF directly: View PDF .
Page Count: 52
Download | |
Open PDF In Browser | View PDF |
Data sheet DS/WM–EN Rev. U WaterMaster Electromagnetic flowmeter Measurement made easy The perfect fit for all water industry applications One solution for all your needs — designed for use in all water and waste water applications, from sewage plants to distribution networks State-of-the-art technology — revolutionary data storage enables transmitter interchange and commissioning without the need for re-configuration — self-calibrating transmitter with ultra-low temperature coefficient for highest accuracy Versatile and simple configuration — 'Through-the-Glass' (TTG) configuration eliminating the need to remove the cover — smart key based functionality — 'Easy Setup' function VeriMaster in situ verification software option — enables the customer to perform in situ verification of the flowmeter system Unparalleled service ability — fault-finding Help texts on the display — minimized downtime with replaceable electronics cartridges MID and OIML R49 approved with R49 self-checking — Type-approved to accuracy Class 1 and Class 2 for any pipe orientation and bidirectional flows — Type P-approved continuous self-checking of the sensor and transmitter to ensure the highest accuracy and long term performance Innovative sensors for all applications — optimized full-bore series for optimum turndown / low pressure drop, irrigation applications — full-bore series for general-purpose water metering applications — reduced-bore series for high turn down applications, for example, leakage — buriable sensors eliminating the need for costly chamber construction HART, PROFIBUS DP and MODBUS — Full system and PLC integration WaterMaster Electromagnetic flowmeter The Company Flow performance ABB is an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental applications. Utilizing its advanced filtering methods, the WaterMaster improves accuracy even under difficult conditions. WaterMaster has an operating flow range with ±0.4 % accuracy as standard (±0.2 % optional) in both forward and reverse flow directions. As a world leader in process automation technology our worldwide presence, comprehensive service and application-oriented know-how make ABB a leading supplier of flow measurement products. Easy and quick commissioning Introduction Setting the standard for the Water Industry The WaterMaster range, available in sizes 10 to 2400 mm (3/8 to 96 in.), is designed specifically for use on the many diverse applications encountered in the Water and Waste-water industry. The modular design concept offers flexibility, cost-saving operation and reliability while providing a long service life and exceptionally low maintenance. Integration into ABB asset management systems and use of the self-monitoring and diagnostic functions increase the plant availability and reduce downtimes. VeriMaster – the verification tool An easy-to-use utility, available through the infra red service port, it uses the advanced self-calibration and diagnostic capability of WaterMaster, coupled with fingerprinting technology, to determine the accuracy status of the WaterMaster flowmeter to within ±1 % of its original factory calibration. VeriMaster also supports printing of calibration verification records for regulatory compliance. 'Fit-and-Flow' data storage inside WaterMaster eliminates the need to match sensor and transmitter in the field. On initial installation, the self-configuration sequence automatically replicates into the transmitter all calibration factors, meter size and serial numbers, as well as customer site-specific settings, eliminating the potential for error. Intuitive, convenient navigation The 'Easy Setup' function reliably guides unpracticed users through the menu step by step. The smart key based functionality makes handling a breeze – it's just like using a cell phone. During configuration, the permissible range of each parameter is indicated on the display and invalid entries are rejected. Universal transmitter – powerful and flexible The backlit display can be rotated easily without the need for tools. The contrast is adjustable and the display fully-configurable. The character size, number of lines and display resolution (number of decimal points) can be set as required. In multiplex mode, several different display options can be pre-configured and invoked one after the other. The smart modular design of the transmitter unit enables easy disassembly without the need to unscrew cables or unplug connectors. HART is used as the standard communications protocol. Optionally, the transmitter is available with PROFIBUS DP or MODBUS communication. Assured quality WaterMaster is designed and manufactured in accordance with international quality procedures (ISO 9001) and all flowmeters are calibrated on nationally-traceable calibration rigs to provide the end-user with complete assurance of both quality and performance of the flowmeter. Diagnostic functions Using its diagnostic functions, the flowmeter monitors both its own operability and the process. Limit values for the diagnostic parameters can be set locally. When these limits are exceeded, an alarm is tripped. In the event of an error, diagnostic-dependent help text appears on the display and this considerably simplifies and accelerates the troubleshooting procedure. In accordance with NAMUR NE107, alarms and warnings are classified with the status of 'Maintenance Required', 'Check Function', 'Failure' and 'Out of Specification'. 2 DS/WM–EN Rev. U WaterMaster Electromagnetic flowmeter WaterMaster – always the first choice Overview of the WaterMaster WaterMaster sets the standard for the water industry. The specification, features and user benefits offered by this range are based on ABB's worldwide experience in this industry and they are all targeted specifically to the industry's requirements. A wide range of features and user benefits are built into WaterMaster as standard: Submersible and buriable WaterMaster sensors have a rugged, robust construction to ensure a long, maintenance-free life under the arduous conditions experienced in the Water and Waste Industry. The sensors are, as standard, inherently submersible (IP68, NEMA 6P), thus ensuring suitability for installation in chambers and metering pits that are susceptible to flooding. A unique feature of the WaterMaster sensors is that sizes DN40 to DN2400 (11/2 to 96 in. NB) are buriable; installation simply involves excavating to the underground pipe, fitting the sensor, cabling back to the transmitter and then backfilling the hole. bi-directional flow unique self-calibrating transmitter (patented) for the ultimate in stability and repeatability OIML-type continuous self-checking, with alarms, ensures both sensor and transmitter accuracy true electrode and coil impedance measurement comprehensive simulation mode universal switch-mode power supply (options are available for AC and DC supplies) comprehensive self-diagnostics compliant with NAMUR NE107 programmable multiple-alarm capability bus options: HART (4 to 20 mA), PROFIBUS DP (RS485), MODBUS (RS485) 3 configurable pulse / frequency and alarm outputs advanced infrared service port supports remote HMI, HART, cyclic data out and parameter download VeriMaster in situ verification software available as option read-only switch and ultra-secure service password for total security The WaterMaster family DS/WM–EN Rev. U 3 WaterMaster Electromagnetic flowmeter OIML / MID approved Superior control through advanced sensor design WaterMaster has been type tested and Internationally approved to the highest accuracy class 1 and 2 for cold and hot potable water meters – OIML R49-1 (Organisation Internationale de Métrologie Légale). For full details, OIML R49 is available to download from www.oiml.org. Its requirements are very similar to other International standards, such as EN14154 and ISO4064. The innovative, patented octagonal sensor design improves flow profile and reduces up- and down-stream piping requirements for the most commonly used sizes of 40 to 200 mm (11/2 to 8 in.). This optimized full bore meter provides impressive results in the most difficult of installation requirements. WaterMaster has been assessed by type approval at the National Measurement Office (NMO) to OIML R49 and passed to the very highest accuracy designations for sizes DN40 to DN200 (11/2 to 8 in. NB). The approval is for: Class 1 and Class 2 accuracy (calibration option) Environmental class T50 for water temperatures of 0.1 to 50 °C (32.18 to 122 °F) Electromagnetic Environment E2 (10 V/m) Any pipe orientation 5 Diameters upstream pipe 0 Diameters downstream pipe Pressure Loss Class <0.25 bar (3.62 psi) Integral or remote transmitter (<200 m [<656 ft.] cable) DN40 to DN200 (11/2 to 8 in. NB), bi-directional flow A major advance in WaterMaster is the self-checking capabilities that meet and exceed the R49 requirements and is the first electromagnetic flowmeter to be approved to OIML Type P permanent self checking during normal operation (not just at startup) and alarm indication for: transmitter and sensor status, with an accuracy alarm program ROM and RAM status double, independent storage of totalizer values, in both the sensor and transmitter non-volatile memories display test The OIML R49-1 certificate of conformity is available from: http://www.abb.com/product/seitp330/b42ec2377d3293cd c12573de003db93b.aspx WaterMaster is also approved under the EU Measuring Instruments Directive (MID) 2004/22/EC, that covers putting into use water flowmeters for certain applications. MID WaterMaster is secured against tamping and is available as an option, along with fingerprinting for ABB VeriMaster in situ verification product, with certificate printout to ±1 % accuracy. WaterMaster certificates of EC type-examination of a measuring instrument are available from: http://www.abb.com/product/seitp330/b42ec2377d3293cd c12573de003db93b.aspx 4 DS/WM–EN Rev. U WaterMaster sensors are also available in reduced-bore geometries giving the ultimate in low-flow performance with a very high turn-down range. The unique design of the reduced-bore sensor conditions the flow profile in the measuring section so that distortions in the flow profile, either upstream or downstream, are flattened. The result is excellent in situ flowmeter performance, even with very bad hydraulic installation conditions. WaterMaster Electromagnetic flowmeter Specification WaterMaster specification to OIML R49 Class 1 DN100 (4 in. NB) WaterMaster Class 1 Specification Error (%) Typical Meter Performance ±0.2 % ±0.9 mm/s whichever is the greater Around Q2 the performance is ±0.7 mm/s OIML R49 Class 1 Accuracy Limits 0.1 (0.44) 1.0 (4.4) 10 (44) 100 (440) 1000 (4402) Flowrate m3/h (GPM) WaterMaster specification to OIML R49 Class 2 DN100 (4 in. NB) Error (%) WaterMaster Class 2 Specification Typical Meter Performance ±0.4 % ±0.9 mm/s whichever is the greater ±0.4 % OIML R49 Class 2 Accuracy Limits Q3 0.1 (0.44) 1.0 (4.4) 10 (44) 100 (440) 1000 (4402) Flowrate m3/h (GPM) Although OIML R49 does not define the flow accuracy below Q1, WaterMaster continues to measure flow at lower flow rates down to a cutoff velocity of ±5 mm/s (±0.2 in./s). The accuracy between cutoff and Q1 is typically ±0.9 mm/s (±0.04. in./s). DS/WM–EN Rev. U 5 WaterMaster Electromagnetic flowmeter WaterMaster optimized full-bore meter (FEV) / full-bore meters (FEF, FEW) flow performance – m3/h Standard Calibration – 0.4 % Class 2 High Accuracy Calibration – 0.2 % Class 1 DN Q4 Q3 Q0.4% Q2 Q1 Q0.2% Q2 Q1 10 3.1 2.5 0.167 0.013 0.008 0.31 0.02 0.012 15 7.88 6.3 0.42 0.032 0.02 0.79 0.05 0.03 20 12.5 10 0.67 0.05 0.032 1.25 0.08 0.05 25 20 16 1.1 0.08 0.05 2 0.13 0.08 0.13 32 31.25 25 1.67 0.13 0.08 3 0.20 40* 50 40 4.2 0.2 0.13 6 0.32 0.2 50* 79 63 4.2 0.32 0.20 7.9 0.5 0.32 65* 125 100 6.7 0.5 0.32 12.5 0.8 0.5 80* 200 160 10.7 0.81 0.51 16 1.3 0.8 100* 313 250 16.7 1.3 0.79 25 2 1.25 125* 313 250 16.7 1.3 0.79 25 2 1.25 150* 788 630 42 3.2 2.0 63 5 3.2 200* 1,250 1,000 67 5.1 3.2 100 8 5 250 2,000 1,600 107 8.1 5.1 160 13 8 300 3,125 2,500 167 12.7 7.9 250 20 12.5 350 5,000 4,000 267 20.3 12.7 400 32 20 400 5,000 4,000 267 20.3 12.7 400 32 20 450 7,875 6,300 420 32 20 630 50 32 500 7,875 6,300 420 32 20 630 50 32 600 12,500 10,000 667 51 32 1000 80 50 700 20,000 16,000 1600 102 64 1600 160 100 750 20,000 16,000 1600 102 64 1600 160 100 30 in (760) 20,000 16,000 1600 102 64 1600 160 100 800 20,000 16,000 1600 102 64 1600 160 100 900 31,250 25,000 2500 160 100 2500 250 156 1000 31,250 25,000 2500 160 100 2500 250 156 42 in 31,250 25,000 2500 160 100 2500 250 156 1100 31,250 25,000 2500 160 100 2500 250 156 1200 50,000 40,000 4000 256 160 4000 400 250 1350 78,750 63,000 6300 403 252 6300 630 394 1400 78,750 63,000 6300 403 252 6300 630 394 1500 78,750 63,000 6300 403 252 6300 630 394 60 in (1500) 78,750 63,000 6300 403 252 6300 630 394 1600 78,750 63,000 6300 403 252 6300 630 394 1650 78,750 63,000 6300 403 252 6300 630 394 1800 125,000 100,000 10000 640 400 10000 1000 625 1950 125,000 100,000 10000 640 400 10000 1000 625 2000 125,000 100,000 10000 640 400 10000 1000 625 2200 200,000 160,000 16000 1024 640 16000 1600 1000 2400 200,000 160,000 16000 1024 640 16000 1600 1000 * OIML R49 Certificate of Conformance to Class 1 and Class 2, with OIML R49 and MID versions available. Note. OIML R49–1 allow Class 1 only for meters with Q3 100 m3/h. Meters outside this range have been tested and conform to Class 1. 6 DS/WM–EN Rev. U WaterMaster Electromagnetic flowmeter WaterMaster optimized full-bore meter (FEV) / full-bore meters (FEF, FEW) flow performance – gal/min Standard Calibration 0.4 % Class 2 NPS/NB (DN) High Accuracy Calibration 0.2 % Class 1 Q4 Q3 Q0.4% Q2 Q1 Q0.2% Q2 Q1 3 13.8 11 0.73 0.06 0.035 1.38 0.09 0.053 1 34.7 27.7 1.85 0.14 0.09 3.48 0.22 0.14 3 /4 (20) 55 44 2.94 0.22 0.14 5.5 0.35 0.22 1 (25) 88 70.4 4.7 0.35 0.22 8.8 0.57 0.35 1 1/4 (32) 137.6 110 7.3 0.57 0.35 13.2 0.88 0.57 1 1/2 (40) 220 176 18.5 0.89 0.56 26.4 1.41 0.88 2 (50) 347 277 18.5 1.41 0.88 34.7 2.22 1.39 2 1/2 (65) 550 440 29.4 2.24 1.40 55.0 3.52 2.20 3 (80) 881 704 47.0 3.58 2.24 70.4 5.64 3.52 4 (100) 1,376 1,101 73.4 5.59 3.49 110 8.81 5.50 5 (125) 1,376 1,101 73.4 5.59 3.49 110 8.81 5.50 6 (150) 3,467 2,774 185 14.1 8.81 277 22.2 13.9 8 (200) 5,504 4,403 294 22.4 14.0 440 35.2 22.0 10 (250) 8,806 7,045 470 35.8 22.4 704 56.4 35.2 12 (300) 13,759 11,007 734 55.9 34.9 1,101 88.1 55.0 14 (350) 22,014 17,611 1,174 89.5 55.9 1,761 141 88.1 16 (400) 22,014 17,611 1,174 89.5 55.9 1,761 141 88.1 18 (450) 34,673 27,738 1,849 141 88.1 2,774 222 139 20 (500) 34,673 27,738 1,849 141 88.1 2,774 222 139 24 (600) 55,036 44,029 2,935 224 140 4,403 352 220 27/28* (700) 88,057 70,446 7,045 451 282 7,045 704 440 29 (750) 88,057 70,446 7,045 451 282 7,045 704 440 30 (760) 88,057 70,446 7,045 451 282 7,045 704 440 32 (800) 88,057 70,446 7,045 451 282 7,045 704 440 36 (900) 137,590 110,072 11,007 704 440 11,007 1,100 688 39/40* (1000) 137,590 110,072 11,007 704 440 11,007 1,100 688 42 (1050) 137,590 110,072 11,007 704 440 11,007 1,100 688 44 (1100) 137,590 110,072 11,007 704 440 11,007 1,100 688 48 (1200) 220,143 176,115 17,611 1,127 704 17,611 1,761 1,101 52 (1350) 346,726 277,381 27,738 1,775 1,110 27,738 2,773 1,733 54 (1400) 346,726 277,381 27,738 1,775 1,110 27,738 2,773 1,733 60 (1500) 346,726 277,381 27,738 1,775 1,110 27,738 2,773 1,733 66 (1600) 346,726 277,381 27,738 1,775 1,110 27,738 2,773 1,733 68 (1650) 346,726 277,381 27,738 1,775 1,110 27,738 2,773 1,733 77 (1800) 550,358 440,287 44,029 2,818 1,761 44,029 4,403 2,752 77 (1950) 550,358 440,287 44,029 2,818 1,761 44,029 4,403 2,752 78 (2000) 550,358 440,287 44,029 2,818 1,761 44,029 4,403 2,752 78 (2000) 550,358 440,287 44,029 2,818 1,761 44,029 4,403 2,752 84 (2200) 880,573 704,459 70,446 4,509 2,818 70,446 7,045 4,403 96 (2400) 880,573 704,459 70,446 4,509 2,818 70,446 7,045 4,403 /8 (10) /2 (15) *Size is dependent on flange specification WaterMaster reduced-bore meter (FER) flow performance – m3/h (gal/min) Class 2 specification Size Q4 Q3 Q0.4 % Q2 Class 1 specification Q1 m3 / h (Ugal / min) m3 / h (Ugal / min) m3 / h (Ugal / min) m3 / h (Ugal / min) m3 / h (Ugal / min) R Q0.2 % Q2 Q1 m3 / h (Ugal / min) m3 / h (Ugal / min) m3 / h (Ugal / min) R mm in. 40 11/2 31 (138) 25 (110) 0.83 (1.05) 0.063 (0.28) 0.04 (0.18) 630 1.7 (7.48) 0.1 (0.44) 0.063 (0.28) 400 50 2 50 (220) 40 (176) 1.0 (4.40) 0.1 (0.44) 0.063 (0.28) 630 2.0 (8.8) 0.16 (0.7) 0.1 (0.44) 400 65 21/2 79 (347) 63 (277) 1.6 (7.04) 0.16 (0.7) 0.1 (0.44) 630 3.2 (10.56) 0.25 (1.1) 0.16 (0.7) 400 80 3 125 (550) 100 (440) 2.0 (8.80) 0.25 (1.1) 0.16 (0.7) 630 4.0 (17.6) 0.4 (1.76) 0.25 (1.1) 400 100 4 200 (880) 160 (704) 3.2 (10.56) 0.41 (1.8) 0.25 (1.1) 630 6.4 (28) 0.64 (2.8) 0.4 (1.76) 400 125 5 200 (880) 160 (704) 3.2 (10.56) 0.41 (1.8) 0.25 (1.1) 630 6.4 (28) 0.64 (2.8) 0.4 (1.76) 400 150 6 500 (2200) 400 (1760) 8.0 (35.20) 1.0 (4.4) 0.63 (2.77) 630 16 (70.4) 1.6 (7) 1.0 (4.4) 400 200 8 788 (3470) 630 (2770) 13.0 (57.2) 1.6 (7.04) 1.0 (4.4) 630 25 (110) 2.5 (11) 1.6 (7) 400 250 10 1250 (5500) 1000 (4400) 20 (88) 2.5 (11.01) 1.6 (7) 630 40 (176) 4.0 (17.6) 2.5 (11) 400 300 12 2000 (8810) 1600 (7045) 32 (140.8) 4.1 (18.05) 2.5 (11) 630 64 (281.6) 6.4 (28) 4.0 (17.6) 200 350 14 2000 (8810) 1600 (7045) 32 (140.8) 6.4 (28.18) 4.0 (17.6) 400 64 (281.6) 12.8 (56) 8.0 (35.2) 200 375 15 2000 (8810) 1600 (7045) 32 (140.8) 6.4 (28.18) 4.0 (17.6) 400 64 (281.6) 12.8 (56) 8.0 (35.2) 200 400 16 3125 (13760) 2500 (11007) 50 (220) 10 (44) 6.3 (27.7) 400 100 (440) 20 (88) 12.5 (55) 200 450 18 3125 (13760) 2500 (11007) 50 (220) 10 (44) 6.3 (27.7) 400 100 (440) 20 (88) 12.5 (55) 200 500 20 5000 (22014) 4000 (17610) 80 (352) 16 (70.45) 10 (44) 400 160 (70.4) 32 (141) 20 (88) 200 600 24 7875 (34670) 6300 (27740) 126 (554.4) 25.2 (110.9) 15.8 (70) 400 252 (1108) 50.4 (222) 31.5 (138.7) 200 DS/WM–EN Rev. U 7 WaterMaster Electromagnetic flowmeter Specification – sensor Physical specification Wetted parts Functional specification Electrode material Stainless steel 316 L / 316 Ti Pressure limitations As per flange rating – non approved PN16 for OIML R49, MID Approved Super-austenitic steel Pressure equipment directive 97/23/EC This product is applicable in networks for the supply, distribution and discharge of water and associated equipment and is therefore exempt. Temperature limitations Hastelloy® C-22 and Hastelloy C4 (other electrode materials available on request) Potential equalizing rings Minimum of 1 recommended Lining material / potable water approvals Ambient temperature Remote transmitter –20 to 70 °C (–4 to 158 °F) Integral transmitter Potable Water Approvals –20 to 60 °C (–4 to 140 °F) Process temperature See table below. 0.1 to 50 °C (32.2 to 122 °F) – OIML R49 T50 Approved Code Size Range Liner WRAS FEW1 DN10 – 32 (3/8 – 11/4 in. NB) PTFE 4 FEW3 DN10 – 600 (3/8 – 24 in. NB) PTFE FEW3 DN40 – 2400 Elastomer (11/2 – 96 in. NB) FEW3 DN40 – 2400 (11/2 – 96 in. NB) Hard rubber 4 FEV DN40 – 200 (11/2 – 8 in. NB) Polypropylene 4 FEF DN250 – 600 (10 – 24 in. NB) Elastomer 4 FEF DN250 – 600 (10 – 24 in. NB) Hard rubber 4 FER DN40 – 600 Elastomer (11/2 – 24 in. NB) Medium temperature °C (°F) Code FEF, FEW3 FEW1 FEW3 Lining Flange material Minimum Maximum Carbon steel –10 (14) 90 (194) Stainless steel –10 (14) 90 (194) Hard rubber Carbon steel –10 (14) 130 (266) Stainless steel –25 (–13) 130 (266) Carbon steel –10 (14) 130 (266) Stainless steel –10 (14) 130 (266) Carbon steel –5 (23) 80 (176) PTFE PTFE FEW3 Elastomer FEF, FER Elastomer FEV Polypropylene Stainless steel –5 (23) 80 (176) –6 (21) 70 (158) –6 (21) 70 (158) Carbon steel IP rating IP68 (NEMA 6) to 7 m (20 ft.) depth Note. Not sizes DN10 to DN32 (3/8 – 11/4 in. NB) IP67 (NEMA 4X) – DN10 to DN32 (3/8 – 11/4 in. NB) Buriable (sensor only) FEV, FEF and FEW – DN450 to 2400 (18 to 96 in. NB) to 5 m (16 ft.) depth Conductivity >5µS cm–1 Transmitter mounting Integral (not FEF) or remote Electrical connections 20 mm glands 1 /2 in. NPT 20 mm armored glands Sensor cable ABB WaterMaster cable available in two forms – standard and armored Maximum length 200 m (660 ft.) 8 DS/WM–EN Rev. U WRAS ACS DVGW 60°C NSF 4 AZ/ NZS 4020 4 4 NSF approved material 4 4 NSF-61 4 4 4 NSF-61 4 4 NSF approved material 4 4 4 4 4 4 *Size is dependent on flange specification Lining protection plates Not required Installation conditions (recommended) FEW / FEF FEV FER Straight pipe requirements Upstream Downstream 5 x DN 2 x DN 5x DN 0 x DN 0 x DN 0 x DN Pressure loss Negligible at Q3 All full bore meters <0.25 bar (<3.62 psi) at Q3 FEV (DN40 to 200 [11/2 to 8 in. NB]) <0.63 bar (<9.13 psi) at Q3 FER (DN40 to 600 [11/2 to 24in. NB]) WaterMaster Electromagnetic flowmeter Non-wetted parts Flange material Carbon steel DN20 to DN2400 (3/4 to 96 in. NB) Stainless steel SG iron DN10 to DN2400 (3/8 to 96 in. NB) FEV – DN40 to DN150 [1 1/2 to 6 in. NB) FER – DN40 to DN150 [1 1/2 to 6 in. NB) Housing material Carbon steel FEV – DN40 to 200 (11/2 to 8 in. NB) Plastic Aluminium FEW – DN450 to 2400 (18 to 96 in. NB) FEF – DN250 to 600 (10 to 24 in. NB) FEW – DN10 to 400 (3/8 to 16 in. NB) Terminal box material Polycarbonate Cable gland material Plastic, brass Paint specification Paint coat 70 µm thick RAL 9002 (light grey) DS/WM–EN Rev. U 9 WaterMaster Electromagnetic flowmeter Specification – transmitter Functional specification Power supply Mains Low voltage DC 85 to 265 V AC @ <7 VA 24 V AC +10 % /–30 % @ <7 VA 24 V ±30 % @ <0.4 A Supply voltage fluctuations within the specified range have no effect on accuracy Digital Outputs (3) Rating 30 V @ 220 mA, open collector, galvanically isolated * Maximum output frequency 5250 Hz 1 off dedicated to Alarm / Logic, programmable function 2 off configurable to either Pulse / Frequency or Alarm/Logic function Current output – HART FEX100 variant 4 to 20 mA or 4 to 12/20 mA, galvanically isolated * Maximum loop resistance 750 HART protocol Version 5.7 (HART registered) Signal levels compliant with NAMUR NE 43 (3.8 to 20.5 mA) Low alarm 3.6 mA, High alarm 21.8 mA Additional accuracy ±0.1 % of reading Temperature coefficient: typically <±20 ppm/°C RS485 Communications – PROFIBUS FEX100-DP variant Registered name: FEX100-DP RS485 (9.6kbps to 1.5Mbps), galvanically isolated DPV0, DPV1 PA Profile 3.01 Environmental protection Humidity: 0 to 100 % Rating: IP67 (NEMA 4X) to 1m (3.3 ft.) depth Tamper-proof security Write access prevented by internal switch combined with external security seals for MID applications Languages English, French, German, Italian, Spanish, Polish Infrared service port USB adapter (accessory), USB 1.1. and 2.0 compatible Driver software for Windows 2000, XP, 7 (32-bit) and Vista Housing material Powder-coated aluminium with glass window Paint specification Paint coat 70 µm thick RAL 9002 (light grey) Transmitter vibration testing Vibration level: 7 m/s2 Frequency range: 20 to 150 Hz No. of sweeps in 3 orthogonal planes: 20 Undetectable shift in transmitter span or zero performance Hazardous approvals (HART variant only) FM & FMc Class 1 Div 2 (FM listing NI / 1 / 2 / ABCD / T4, S / II, III / 2 / FG /T4, Ta=60C; Type 4X, IP67 – for transmitter and integral mounting Ta=70C, Type 6P, IP68 – for remote sensor type, IP67 on DN10 to 32 [3/8 to 11/4 in.NB]) (FMc listing NI / 1 / 2 / ABCD / T4, DIP / II, III / 2 / FG /T4, Ta=60C; Type 4X, IP67 – for transmitter and integral mounting Ta=70C, Type 6P, IP68 – for remote sensor type, IP67 on DN10 to 32 [3/8 to 11/4 in.NB]) Standard idents: 9700, 9740, 9741 FET, FEV, FEW and FEF DN700 to 2200 (27/28* to 84 in. NB) only FEX100-DP specific ident: 3431 *Size is dependent on flange specification 3 Concurrent MS2 master connections RS485 Communications – MODBUS FEX100-MB variant MODBUS RTU protocol RS485 (9.6kbps to 115.2kbps), galvanically isolated Electrical connections 20 mm glands 1/2 in. NPT, 20 mm armored glands Temperature limitations Ambient temperature –20 to 60 °C (–4 to 140 °F) Temperature Typically <±10 ppm/°C @ Vel 0.5 mls coefficient ATEX* Zone 2, 21 & 22 II 3 G Ex nA IIC T5 Gc II 2 D Ex tb IIIC T100°C Db TA = –20°C to +60°C (integral transmitter) TA = –20°C to +70°C (remote sensor) IECEx* Zone 2, 21 & 22 Ex tb IIIC T100°C Db Ex nA IIC T5 Gc TA = –20°C to +60°C (integral transmitter) TA = –20°C to +70°C (remote sensor) *FEW, FEV, FET and FEF 700 (27/28 in. NB) only Declaration of Conformance Copies of CE certification will be available on request. WaterMaster has OIML R49 Certificate of Conformity to accuracy class 1 and 2 (FEV DN40 to 200 [11/2 to 8 in.NB]). Copies of accuracy certification are available on request. WaterMaster (FEV DN40 to 200 [11/2 to 8 in.NB]) has been type examined under directive MID 2004/22/EC, Annex MI-001. Copies of this certificate are available on request. * When installed, do not leave galvanically isolated circuits (pulse and current) floating. 10 DS/WM–EN Rev. U WaterMaster Electromagnetic flowmeter Transmitter connections Transmitter terminal connections overview This section is intended to give an overview of installation of a flowmeter. For Installation requirements, technical information and Health and safety precautions – refer to the User Guide OI/FET100–EN. Test Points for Output Connections AC / DC Power Supply Terminal Sensor Cable Terminal Output Connections Terminal Backplane Internal Earth (Alternative PE) Internal Earth (Alternative PE) External Earth Power Cable Output Connections Output Connections Sensor Cable Cable gland / conduit entry (Remote transmitter shown) Sensor cable terminal connections and recommended cable lengths Cut cables to 60 mm (2.35 in.) Cut cables to 70 mm (2.75 in.) M1 Brown M2 Red D1/TFE Orange D2 Yellow 3 Green (Sleeve) S2 Blue (Screen) E2 E1 Blue Violet (*Signal) (*Signal) S1 Violet Screen) SCR Screen **Drain Wire (Twisted with screen from D1/TFE – Orange and D2 – Yellow) See above for cable preparation requirements before connecting cable *Inner wire **For cathodically-protected systems (or if the transmitter enclosure does not have an earth screw) connect the drain wire to terminal SCR. Sensor cable connections at transmitter terminal block – remote transmitter DS/WM–EN Rev. U 11 WaterMaster Electromagnetic flowmeter Power supply connections AC power supply Power Supply Indicator LED *AC Fuse F1 250 mA Type T (see table below for suppliers) Internal Earth Screws** **Can be used as a Protective Earth (PE) if required by national standards Brown Blue Green / Yellow AC power via a suitable isolator and fuse *Fuse Supplier ABB Fuse Part Number B20411 Bussmann BK/ETF 250 mA Wickmann 19372 K250mA External Earth Screw 2 >4 mm (<10 AWG) Copper Wire Transmitter Label AC power supply connections DC (and low voltage AC) power supply Power Supply Indicator LED *DC Fuse F2 2 A Type T (see table below for suppliers) Internal Earth Screws Red Black Green / Yellow External Earth >4 mm2 (<10 AWG) Copper Wire *Fuse Supplier ABB Fuse Part Number B20412 Bussmann BK/ETF2A Wickmann 19372 K2A DC (or Low Voltage AC) power via suitable Isolator and fuse Transmitter Label (DC) DC (and low voltage AC) power supply connections 12 DS/WM–EN Rev. U WaterMaster Electromagnetic flowmeter Configuration DIP switches Three configuration DIP switches are mounted on the transmitter backplane board. These are factory-set as follows: Remote transmitter – all OFF Transmitter module identification Note. The communications bus type is HART FEX100 if not specified on the transmitter module label. An example of the PROFIBUS FEX100-DP variant transmitter module label is shown below. Integral transmitter – SW3 ON For MID-compliant flowmeters the read-only / MID protection switch is set to 'ON' to ensure the meter is secure from tampering. For HART software versions prior to 01.02.XX, this switch (set after commissioning) prevents login via the keypad or bus at any security level. From HART software version 01.03.XX onwards and for all PROFIBUS software versions, on MID meters, all metrological-related parameters are locked and inaccessible at the Service level. Standard and Advanced user level parameters can still be modified via the HMI or bus. PROFIBUS FEX-100P Label Configuration DIP Switches OFF ON SW3 SW2 SW1 Red Label on DC (and Low Voltage AC) Converter Module DIP Switch Functions SW1 – Read-only / MID Protection SW2 – (Future Product) SW3 – Internal Sensor Memory Black Label on AC Converter Module Configuration DIP switches Transmitter module identification DS/WM–EN Rev. U 13 WaterMaster Electromagnetic flowmeter Output connections Frequency outputs Alarm outputs PLC or Datalogger XX XX XX XX 42 41 51 61 52 62 Terminal connection IDs are HART- / PROFIBUS- / MODBUSvariant dependent COM DO3 COM DO1 DO2 Alarm 1 PLC / Datalogger connections Note. Digital outputs DO1 and DO2 are polarity sensitive. The common (negative) connection for these outputs is designated 'COM'. Bell DC Supply COM + XX XX XX XX 42 41 51 61 52 62 – Terminal connection IDs are HART- / PROFIBUS-variant dependent DO1 DO2 DO3 and / or Horn Alarm 2 Forward Flow Output (DO1) Counter / Totalizer DC Supply 1 2 34 56 – + Note. XX XX XX XX 42 41 51 61 52 62 COM DO1 and / or DO2 1 2 34 56 Reverse Flow Output (DO2) Counter / Totalizer Normal alarm / logic output is from DO3 (terminal 61). DO1 (41) and DO2 (51) can also be configured as alarms if required but are then NOT available as frequency / pulse outputs as shown in Electromechanical connections and Telemetry / Electronic counters connections, opposite. Bell and horn shown for example only. Any suitable alarm device may be used (for example, lamp, siren, buzzer etc.). Electromechanical connections Forward Flow Output (DO1) Counter / Totalizer COM DO1 DO2 + Alarm 1 and / or DC Supply Timer Switch – 1 2 34 56 + Reverse Flow Output (DO2) Counter / Totalizer + XX XX XX XX 42 41 51 61 52 62 1 2 34 56 XX XX XX XX 42 41 51 61 52 62 COM DO1 DO2 – – R Alarm 2 Relay and / or Telemetry / Electronic counters connections Note. Relay and timer switch shown for example only. 14 DS/WM–EN Rev. U WaterMaster Electromagnetic flowmeter PLC interface Current output (4 to 20 ma) – HART (FEX100) variant 24 V PLC + Typically 1k 1W XX XX XX XX 42 41 51 61 52 62 Fwd + DC Supply DO1 Rev + DO2 – COM + – Refer to IM/WMP for HART-Protocol communication details Current output (4 to 20 mA) – HART (FEX100) variant RS485 communications – PROFIBUS (FEX100-DP) and MODBUS (FEX100-MB) variants + Com XX XX XX XX 42 41 51 61 52 62 DC Supply PROFIBUS / MODBUS RS485 A1 / B1 – In A2 / B2 – Out – COM DO1 DO2 Screen Clamp PLC Fwd – Rev – Com Test point access Note. WaterMaster digital outputs are NPN optocoupled transistors used as switches. Note. A typical DVM probe can access (fit) the PCB's test holes. Maximum allowed voltage at collector is 30 V DC Maximum 220 mA. allowed current across transistor is 4 to 20 mA IC+* IC–* Not Used 31 32 XX 41 42 51 61 VR Frequency O/P1 Outputs COM O/P2 O/P3 Alarm Output Not Used *These 2 test points are connected on the HART FEX100 backplane only (they are present on the PROFIBUS FEX100-DP / MODBUS FEX100-MB backplane but not connected) DS/WM–EN Rev. U 15 WaterMaster Electromagnetic flowmeter Digital communication The transmitter communication. has the PROFIBUS DP protocol following options for digital HART protocol The unit is registered with HART Communication Foundation. PROFIBUS is a manufacturer-independent, open Fieldbus standard for a wide range of applications in manufacturing, process and building automation. Manufacturer independence and openness are ensured by the international standard EN 50170. PROFIBUS DP ID no. 0x3431 Alternative standard ID no. 0x9701 or 0x9741 Configuration Directly on the device Software Asset Vision Basic (+PROFIBUS DP-DTM) Transmission signal Accuracy to IEC 61158-2 Cable Shielded, twisted cable (accurate to IEC 61158-2, types A or B) Multidrop Connection Single Connection HART Connections at Terminal Block 4 mA Current Output (Multidrop Connection) 4 to 20 mA Current Output (Single Connection) – see User Guide IM/WMP 250 Minimum Load HART FSK-Modem or Handheld Terminal PC connection (USB or RS232) Sensor All devices are connected in a bus structure ('line') as shown in below. Up to 32 stations (master or slaves) can be linked to create one 'segment', although it is recommended not to install more than 16 devices on a single segment. Each end of a segment must be terminated by an active bus terminating resistor. Both bus terminators must always be powered to ensure fault-free operation, therefore it is strongly recommended that they are connected to a back-up power supply. The use of bus amplifiers (repeaters) and segment couplers can be used to extend the network. HART protocol Configuration Directly on the Device Software Asset Vision Basic (+ HART -DTM) Transmission Install a HART modem (FSK [Frequency Shift Keyed]-Modem) for HART-Communication when connecting to a PC. The HART-Modem converts the analog 4 to 20 mA signal into a digital output signal (Bell Standard 202) and connects to the PC using a USB (or RS232C) connector Operational Level Operate Engineer Master Level Control PROFIBUS-DP Max. signal amplitude 1.2 mA Current output load Min. 250, max. = 560 Cable AWG 24 twisted Max. cable length 1500 m (4921 ft.) Baud rate 1.200 baud System integration WaterMaster can be integrated into control systems and configuration devices using any Frame application, such as ABB AssetVision or similar third-party applications. ABB Device Type Managers (DTMs) for WaterMaster provide a unified structure for accessing device parameters, configuring and operating the devices and diagnosing problems. FDT (Field Device Tool) technology standardizes the communication and configuration interface between all field devices and host systems. 16 DS/WM–EN Rev. U WaterMaster FEX100-DP Slave Level DP / PA Link PROFIBUS-PA WaterMaster Electromagnetic flowmeter System integration Cable Properties The GSD file for WaterMasters specifies the device-specific Ident No. 3431. It conforms to the PROFIBUS standard, providing a clear and comprehensive description of each instrument in a precisely defined format. The end-to-end length of the trunk cable must be limited. The maximum length depends on the Baud rate, the cable (gauge, capacitance or characteristic impedance), the number of loads on the daisy chain and the network configuration (2-wire or 4-wire). This enables the system configuration tool to use the information automatically when configuring a PROFIBUS bus system. The ABB GSD file (Ident No. 3431) is divided into 2 sections: General specifications Identification of the device, together with hardware and software versions, baud rates supported and the possible time intervals for monitoring times. DP slave-related specifications Information about the user parameter block for device-specific configuration and modules containing details of the input and output data that can be exchanged cyclically with a PROFIBUS master. The WaterMaster GSD file (ABB_3431.gsd) is available for download from the ABB website at: www.abb.com/fieldbus (follow the link for PROFIBUS DP field devices). MODBUS protocol MODBUS is an open standard that is owned and administered by an independent group of device manufacturers called the Modbus Organization (www.modbus.org). Using the MODBUS protocol, devices from different manufacturers exchange information on the same communications bus without the need for special interface equipment. WaterMaster FEX100-MB follows the specification for Modbus Over Serial Line V1.02, using 2-wire TIA/EIA-485 (RS485) physical layer. For 9600 Baud rate and AWG26 (or wider) gauge, the maximum length is 1000 m (3280 ft.). Where 4-wire cabling is used as a 2-wire cabling system the maximum length must be divided by 2. The tap cables must be short, never more than 20 m (65.6 ft.). If a multi-port tap is used with n derivations, each one must have a maximum length of 40 m (131 ft.) divided by n. The maximum serial data transmission line length for RS485 systems is 1200 m (3937 ft.). The lengths of cable that can be used are determined by the cable type, typically: Up to 6 m (19.7 ft.) – standard screened or twisted pair cable. Up to 300 m (984 ft.) – twin twisted pair with overall foil screen and an integral drain wire – for example, Belden 9502 or equivalent. Up to 1200 m (3937 ft.) – twin twisted pair with separate foil screens and integral drain wires – for example, Belden 9729 or equivalent. Category 5 cables may be used for RS485-MODBUS to a maximum length of 600 m (1968 ft.). For the balanced pairs used in an RS485-system, a characteristic impedance with value higher than 100 is preferred especially for 19200 and higher Baud rates. Master 5 D Line Terminator R Pull Pull Up D0 Balanced Pair Line D1 Common D R Slave 1 D Pull Down R Slave n Up to 31 slaves For example, WaterMaster FEX100–MOD DS/WM–EN Rev. U 17 WaterMaster Electromagnetic flowmeter Installation requirements Mounting This section is intended to give an overview of installation of a flowmeter. For Installation requirements, technical information and Health and Safety precautions refer to User Guide OI/FEF/FEV/FEW–EN. The installation conditions shown below must be observed to achieve the best operational results. The sensor tube must always be completely full. Unpacking the flowmeter Care must be taken when lifting the flowmeter to use the lifting hooks provided or sling under the body of the meter. Never lift using the terminal connection box of the sensor cable as this will cause damage and invalidate warranty. Sling Angle <90° The flow direction must correspond to the identification plate. The device measures the flowrate in both directions. Forward flow is the factory setting. The devices must be installed without mechanical tension (torsion, bending). If required support the pipeline. Supports Grounding The flowmeter sensor must be cross-bonded to the upstream and downstream pipes and fluid. For technical reasons, this potential should be identical to the potential of the metering fluid. For plastic or insulated lined pipelines, the fluid is grounded by installing a minimum of 1 earthing rings. When there are stray potentials present in the pipeline, an earthing ring is recommended on both ends of the meter sensor. The flange seals must be made from a compatible material for the fluid and fluid temperatures if required. 70 / 130 °C (158 / 266 °F) Max. Fluid contact rings – 20 °C (– 4 °F) Min. Seals must not extend into the flow area since possible turbulence could influence the device accuracy. Fit Gaskets Gaskets Same Size as Pipe 18 DS/WM–EN Rev. U WaterMaster Electromagnetic flowmeter The pipeline may not exert any unallowable forces and torques on the device, such as vibration. Electrode axis Electrode axis should be horizontal if at all possible or no more than 45° from horizontal. 45 ° Max. The flowmeter must not be submitted to any localized heat during installation; take care to remember this is a measuring instrument. Upstream and Downstream pipe sections The metering principle is tolerant of the flow profile. Wherever possible do not install fittings (for example, manifolds, valves) directly in front of the flowmeter sensor. Butterfly valves should be installed so that the valve plate does not extend into the flowmeter sensor. The flowmeter must not be exposed to direct sunlight or provide for appropriate sun protection where necessary. Valves or other turn-off components should be installed in the Downstream pipe section. Experience has shown that, in most installations, straight upstream sections 3 x DN long and straight downstream sections 2 x DN long are normally sufficient. We would recommend conditions of 5 x DN straight upstream and 2 x DN straight downstream where possible. For reduced-bore meters (FER), these straight pipe sections are often not necessary. The cable to the flowmeter should be installed neatly or within a conduit, both loose or conduit should have a u shape below the terminal connection box height to allow any water run off to avoid any capillary action into the flowmeter sensor. 5 x DN (FEW, FEF) 2 x DN (FEW, FEF) 0 x DN (FER) 0 x DN (FER) 5 x DN (FEV) 0 x DN (FEV) DS/WM–EN Rev. U 19 WaterMaster Electromagnetic flowmeter Transmitter dimensions Integral transmitter Remote transmitter Dimensions in mm (in.) 98 (3.8) 202 (8.0) R3.2 (0.12) 179 (7.0) 200 (7.9) 98 (3.8) 118 (4.6) 71 (2.8) Sensor dimensions FEW – DN10 to 125 (3/8 to 5 in. NB) Dimensions in mm (in.) 77.8 (3.06) Ø104 (4.1) E F 78 (3.1) 210 (7.91) 89 (3.5) 98 (3.86) 104.5 (4.11) G D C A L DN10 to 125 (3/8 to 5 in. NB) (FEW) 20 DS/WM–EN Rev. U 205 (8.0) Dimensions in mm (in.) WaterMaster Electromagnetic flowmeter Dimensions in mm (in.) Approx. weight in kg (lb) DN Process connection type D L F C E G A Integral Remote DN10 (3/8 in.) JIS10K 90 (3.54) 200 (7.87) 268 (10.55) 82 (3.23) 193 (7.6) 148 (5.83) 113 (4.45) 6 (13) 4 (9) PN10 to 40 90 (3.54) ASME B16.5 CL150 90 (3.54) 8 (18) 6 (13) ASME B16.5 CL300 96 (3.78) PN10 to 40 95 (3.74) DN15 (1/2 in.) JIS5K 80 (3.15) JIS10K 95 (3.74) ASME B16.5 CL300 95 (3.74) ASME B16.5 CL150 90 (3.54) PN10 to 40 105 (4.13) JIS5K 85 (3.35) JIS10K 100 (3.94) ASME B16.5 CL300 115 (4.53) DN20 (3/4 in.) ASME B16.5 CL150 98 (3.86) PN10 to 40 115 (4.53) JIS5K 95 (3.74) JIS10K 125 (4.88) ASME B16.5 CL300 125 (4.88) DN25 (1 in.) ASME B16.5 CL150 108 (4.25) PN10 to 40 140 (5.51) JIS5K 115 (4.53) JIS10K 135 (5.31) ASME B16.5 CL300 135 (5.31) DN32 (11/4 in.) ASME B16.5 CL150 117 (4.61) PN10 to 40 150 (5.91) JIS5K 120 (4.72) DN40 (11/2 in.) JIS10K 140 (5.51) ASME B16.5 CL300 155 (6.10) ASME B16.5 CL150 127 (5.00) DN50 (2 in.) PN10 to 40 165 (6.5) JIS5K 130 (5.12) JIS10K 155 (6.10) AS4087 PN16 150 (5.91) AS4087 PN35 165 (6.50) ASME B16.5 CL150 152 (5.98) ASME B16.5 CL300 165 (6.50) PN10 to 40 185 (7.28) JIS5K 155 (6.10) DN65 (21/2 in.) JIS10K 175 (6.89) AS4087 PN16 165 (6.50) AS4087 PN35 185 (7.28) ASME B16.5 CL150 178 (7.01) ASME B16.5 CL300 190 (7.48) PN10 to 40 200 (7.87) JIS5K 180 (7.09) DN80 (3 in.) JIS10K 185 (7.28) AS4087 PN16 185 (7.28) AS4087 PN35 205 (8.07) ASME B16.5 CL150 190 (7.48) ASME B16.5 CL300 210 (8.28) PN10 to 16 220 (8.66) PN25 to 40 DN100 (4 in.) 200 (7.87) 250 (9.84) 268 (10.55) 82 (3.23) 193 (7.6) 148 (5.83) 113 (4.45) 9 (20) 7 (15) 275 (10.83) 92 (3.62) 200 (7.87) 155 (6.10) 113 (4.45) 10 (22) 8 (18) 11 (24) 9 (20) 281 (11.06) 97 (3.82) 206 (8.11) 161 (6.34) 115 (4.53) 12 (26) 10 (22) 292 (11.50) 108 (4.25) 217 (8.54) 172 (6.77) 104 (4.09) 13 (29) 11 (24) 15 (33) 13 (29) 292 (11.5) 108 (4.25) 217 (8.54) 172 (6.77) 104 (4.09) 17 (37) 15 (33) 19 (42) 17 (37) 314 (12.36) 122 (4.8) 239 (9.41) 194 (7.64) 125 (4.92) 19 (42) 17 (37) 235 (9.25) 23 (51) 21 (46) 19 (42) 17 (37) JIS5K 200 (7.87) JIS10K 210 (8.27) AS4087 PN16 215 (8.46) AS4087 PN35 230 (9.06) 23 (51) 21 (46) ASME B16.5 CL300 255 (1.04) 30 (66) 28 (62) ASME B16.5 CL150 229 (9.00) 21 (51) 19 (42) PN10 to 16 250 (9.84) PN25 to 40 DN125 (5 in.) 22 (48) 20 (44) 270 (10.63) 29 (64) 27 (59) 22 (48) 20 (44) 35 (77) 33 (73) JIS5K 235 (9.25) JIS10K 250 (9.84) ASME B16.5 CL150 254 (10.00) ASME B16.5 CL300 280 (11.02) 324 (12.76) 130 (5.12) 249 (9.8) 204 (8.03) 125 (4.92) 3 DN10 to 125 ( /8 to 5 in. NB) (FEW) dimensions / weights DS/WM–EN Rev. U 21 WaterMaster Electromagnetic flowmeter FEW – DN150 to 400 (6 to 16 in. NB) Dimensions in mm (in.) 104.5 (4.11) 77.8 (3.06) Ø104 (4.1) 201 (7.91) 98 (3.86) 78 (3.1) 89 (3.5) G D C A L DN150 to 400 (6 to 16 in. NB) (FEW) 22 DS/WM–EN Rev. U E F WaterMaster Electromagnetic flowmeter Dimensions in mm (in.) Approx. weight in kg (lb) DN Process connection type D L F C E G A Integral DN150 (6 in.) PN10 to 16 285 (11.22) 300 (11.81) 371 (14.61) 146 (9.88) 296 (11.65) 251 (9.88) 166 (6.54) 33 (73) 31 (68) PN25 to 40 300 (11.81) 39 (86) 37 (81) 33 (73) 31 (68) 37 (81) DN200 (8 in.) DN250 (10 in.) DN300 (12 in.) DN350 (14 in.) DN400 (16 in.) Remote JIS5K 265 (10.43) JIS10K 280 (11.02) AS4087 PN16 280 (11.02) AS4087 PN35 305 (11.81) 39 (86) ASME B16.5 CL300 320 (12.60) 47 (103) 45 (99) ASME B16.5 CL150 279 (10.98) 33 (73) 31 (68) PN10 340 (13.39) 41 (90) 39 (86) PN16 340 (13.39) PN25 360 (14.17) 55 (121) 53 (117) PN40 375 (14.76) 65 (143) 63 (139) AS4087 PN16 335 (13.19) 41 (90) 39 (86) AS4087 PN35 370 (14.57) 65 (143) 63 (139) 41 (90) 39 (86) 350 (13.78) 411 (16.18) 170 (6.69) 336 (13.23) 291 (11.46) 200 (7.87) JIS5K 320 (12.60) JIS10K 330 (12.99) ASME B16.5 CL300 380 (14.96) 72 (158) 70 (154) ASME B16.5 CL150 345 (13.58) 50 (110) 48 (106) PN10 395 (15.55) PN16 450 (17.72) 61 (134) 59 (130) 405 (15.94) 65 (143) 63 (139) PN25 425 (16.73) 84 (185) 82 (180) PN40 450 (17.72) 95 (209) 93 (205) AS4087 PN16 405 (15.94) 65 (143) 63 (139) AS4087 PN35 430 (16.93) 95 (209) 93 (205) JIS5K 385 (15.16) 65 (143) 63 (139) JIS10K 400 (15.75) ASME B16.5 CL300 445 (17.52) 105 (231) 103 (227) ASME B16.5 CL150 405 (15.94) 70 (154) 68 (150) PN10 445 (17.52) PN16 500 (19.69) 426 (16.77) 449 (17.68) 198 (7.80) 228 (8.98) 351 (13.82) 374 (14.72) 306 (12.05) 329 (12.95) 235 (9.62) 272 (10.71) 74 (163) 72 (158) 460 (18.11) 80 (176) 78 (172) PN25 485 (19.09) 100 (220) 98 (216) JIS5K 430 (16.93) 80 (176) 78 (172) JIS10K 445 (17.52) AS4087 PN16 455 (17.91) AS4087 PN35 490 (19.29) 130 (286) 128 (282) ASME B16.5 CL300 520 (20.47) 150 (330) 148 (326) ASME B16.5 CL150 485 (19.09) 105 (231) 103 (227) PN40 515 (20.28) 600 (23.62) 130 (286) 128 (282) PN10 505 (19.88) 550 (21.65) PN16 95 (209) 93 (205) 520 (20.47) 110 (242) 108 (238) 145 (319) 143 (315) PN25 555 (21.85) JIS5K 480 (18.90) 464 (18.27) 265 (10.43) 389 (15.31) 344 (13.54) 322 (12.68) 95 (209) 93 (205) JIS10K 490 (19.29) AS4087 PN16 525 (20.67) 130 (286) 128 (282) AS4087 PN35 550 (21.65) 185 (407) 183 (403) ASME B16.5 CL300 585 (23.03) 140 (308) 138 (304) ASME B16.5 CL150 535 (21.06) 105 (231) 103 (227) PN40 580 (22.83) 650 (25.59) 195 (429) 193 (425) PN10 565 (22.24) 600 (23.62) PN16 580 (22.83) 506 (19.92) 265 (10.43) 431 (16.97) 386 (15.20) 322 (12.68) 103 (227) 101 (222) 126 (277) 124 (273) PN25 620 (24.41) 170 (374) 168 (370) JIS5K 540 (21.26) 103 (227) 101 (223) JIS10K 560 (22.05) 116 (255) 114 (251) AS4087 PN16 580 (22.83) 154 (339) 152 (335) AS4087 PN35 610 (24.02) 302 (664) 300 (660) ASME B16.5 CL300 650 (25.59) 265 (583) 263 (578) ASME B16.5 CL150 600 (23.62) 175 (385) 173 (381) PN40 660 (25.98) 258 (568) 256 (564) 650 (25.59) DN150 to 400 (6 to 5 in. NB) (FEW) dimensions / weights DS/WM–EN Rev. U 23 WaterMaster Electromagnetic flowmeter FEW – DN450 to 2400 (18 to 96 in. NB) Dimensions in mm (in.) 104.5 98 (4.11) (3.86) 77.8 (3.06) 104 (4.1) 78 (3.1) 201 (7.91) 89 (3.5) E F G D C A L (1.0D) L (1.3D) DN450 to 2400 (18 to 96 in. NB) (FEW) Dimensions in mm (in.) Approx. weight in kg (lb) DN Process connection type D L (1.0D) L (1.3D) F C E G A Integral Remote DN450 (18 in.) PN10 615 (24.21) N/A 600 (23.62) 514 (20.24) 310 (12.20) 439 (17.28) 394 (15.51) 328 (12.91) 173 (381) 171 (377) DN500 (20 in.) DN600 (24 in.) PN16 640 (25.20) 188 (414) 186 (410) JIS5K 605 (23.82) 165 (364) 163 (359) JIS10K 620 (24.41) 177 (390) 175 (386) AS4087 PN16 640 (25.20) 232 (511) 230 (507) AS4087 PN35 675 (26.57) 328 (723) 326 (718) ASME B16.5 CL300 710 (27.95) 368 (811) 366 (807) ASME B16.5 CL150 635 (25.00) 250 (551) 248 (547) PN25 670 (26.38) 245 (540) 243 (536) PN40 685 (26.97) 315 (694) 313 (690) PN10 670 (26.38) PN16 715 (28.15) N/A 686 (27.01) N/A 600 (23.62) 514 (20.24) 310 (12.20) 439 (17.28) 394 (15.51) 367 (14.45) 190 (418) 188 (413) 240 (528) 238 (524) 190 (418) 188 (413) JIS5K 655 (25.79) JIS10K 675 (26.57) AS4087 PN16 705 (27.76) 290 (638) 288 (634) AS4087 PN35 735 (28.94) 435 (957) 433 (953) ASME B16.5 CL150 700 (27.56) 300 (660) 298 (656) ASME B16.5 CL300 775 (30.51) N/A 762 490 (1080) 488 (1076) PN25 730 (28.74) N/A 700 300 (661) 298 (657) PN40 755 (29.72) N/A 762 392 (864) 390 (860) PN10 780 (30.71) N/A 284 (626) 282 (622) PN16 840 (33.07) 800 (31.50) 318 (700) 316 (695) PN25 845 (33.27) 460 (1012) 458 (1008) 565 (22.24) 361 (14.21) 490 (19.29) 445 (17.52) 469 (18.46) JIS5K 770 (30.31) 275 (605) 273 (600) JIS10K 795 (31.30) 306 (673) 304 (668) AS4087 PN16 825 (32.48) 382 (840) 380 (835) AS4087 PN35 850 (33.46) 452 (994) 450 (990) ASME B16.5 CL300 915 (36.02) 550 (1210) 548 (1205) ASME B16.5 CL150 815 (32.09) PN40 890 (35.04) N/A 890 DN450 to 2400 (18 to 96 in. NB) (FEW) dimensions / weights 24 DS/WM–EN Rev. U 425 (935) 423 (930) 600 (1320) 598 (1316) WaterMaster Electromagnetic flowmeter Dimensions in mm (in.) Approx. weight in kg (lb) DN Process connection type D L (1.0D) L (1.3D) F C E G A Integral Remote DN700 (28 in.) JIS 5K 875 (34.45) 700 (27.56) 910 (35.83) 604 (23.77) 403 (15.87) 528 (20.79) 488 (19.21) 444 (17.48) 216 (475) 214 (471) DN750 (30 in.) DN800 (32 in.) DN900 (36 in.) JIS 10K 905 (35.63) 282 (620) 280 (616) PN6 860 (33.86) 225 (495) 223 (491) PN10 895 (35.24) 303 (667) 301 (662) PN16 910 (35.83) 337 (741) 335 (737) AWWA C207 CLASS B 927 (36.50) 249 (548) 247 (543) AWWA C207 CLASS D 927 (36.50) 280 (616) 278 (612) AS4087 PN16 910 (35.83) 359 (790) 357 (785) AS2129 TABLE-D 910 (35.83) 263 (579) 261 (574) AS2129 TABLE-E 910 (35.83) 337 (741) 335 (737) PN25 960 (37.80) 471 (10.36) 469 (1032) PN40 995 (39.17) 586 (1289) 584 (1285) AWWA C207 CLASS E 927 (36.50) 472 (1038) 470 (1034) AWWA C207 CLASS F 1035 (40.75) 715 (1573) 713 (1569) AS4087 PN35 935 (36.80) 539 (1186) 537 (1181) ASME CL150 SERIES A 925 (36.42) 503 (1107) 501 (1102) ASME CL150 SERIES B 835 (32.87) 323 (711) 321 (706) ASME CL300 SERIES B 920 (36.22) 631 (1388) 629 (1384) JIS 5K 945 (37.20) JIS 10K 970 (38.19) 750 (29.52) 990 (38.98) 630 (24.79) 429 (16.89) 554 (21.81) 514 (20.23) 444 (17.48) 251 (552) 249 (548) 327 (719) 325 (715) 271 (596) AWWA C207 CLASS B 984 (38.74) 273 (601) AWWA C207 CLASS D 984 (38.74) 344 (757) 342 (752) AS4087 PN16 995 (39.17) 467 (1027) 465 (1023) AS2129 TABLE-D 995 (39.17) 340 (748) 338 (744) AS2129 TABLE-E 995 (39.17) 454 (999) 452 (994) AWWA C207 CLASS E 984 (38.74) 496 (1091) 494 (1087) AWWA C207 CLASS F 1092 (43.99) 790 (1738) 788 (1734) AS4087 PN35 1015 (39.96) 663 (1459) 661 (1454) ASME CL150 SERIES A 985 (38.78) 544 (1197) 542 (1192) ASME CL150 SERIES B 885 (34.84) 320 (704) 318 (700) ASME CL300 SERIES B 990 (38.98) 748 (1646) 746 (1641) JIS 5K 995 (39.17) JIS 10K 1020 (40.16) 800 (31.49) 1040 (40.04) 654 (25.74) 453 (17.83) 578 (22.76) 538 (21.18) 542 (21.34) 280 (616) 278 (612) 364 (801) 362 (796) 292 (642) PN6 975 (38.39) 294 (647) PN10 1015 (39.96) 406 (893) 404 (889) PN16 1025 (40.35) 469 (1032) 467 (1027) 326 (717) AWWA C207 CLASS B 1060 (41.73) 328 (722) AWWA C207 CLASS D 1060 (41.73) 408 (898) 406 (893) AS4087 PN16 1060 (41.73) 530 (1166) 528 (1162) AS2129 TABLE-D 1060 (41.73) 386 (849) 384 (845) AS2129 TABLE-E 1060 (41.73) 519 (1142) 517 (1137) PN25 1085 (42.72) 615 (1353) 613 (1349) PN40 1140 (44.88) 866 (1905) 864 (1901) AWWA C207 CLASS E 1060 (41.73) 634 (1395) 632 (1390) AWWA C207 CLASS F 1150 (45.28) 897 (1973) 895 (1969) AS4087 PN35 1060 (41.73) 751 (1652) 749 (1648) ASME CL150 SERIES A 1060 (41.73) 700 (1540) 698 (1536) ASME CL150 SERIES B 940 (37.01) 406 (893) 404 (889) ASME CL300 SERIES B 1055 (41.54) 933 (2053) 931 (2048 JIS 5K 1095 (43.11) JIS 10K 1120 (44.09) 900 (35.43) 1170 (46.06) 705 (27.7() 504 (19.84) 629 (24.76) 589 (23.19) 570 (22.44) 369 812) 367 (807) 445 (979) 443 (975) PN6 1075 (42.32) 390 (858) 388 (854) PN10 1115 (43.90) 502 (1104) 500 (1100) 587 (1291) PN16 1125 (44.29) 589 (1296) AWWA C207 CLASS B 1168 (45.98) 417 (917) 415 (913) AWWA C207 CLASS D 1168 (45.98) 493 (1085) 491 (1080) AWWA C207 CLASS E 1168 (45.98) 827 (1819) 825 (1815) AWWA C207 CLASS F 1270 (50.00) 1150 (2530) 1148 (2526) AS4087 PN16 1175 (46.26) 706 (1553) 704 (1549) AS2129 TABLE-D 1175 (46.26) 514 (1131) 512 (1126) AS2129 TABLE-E 1175 (46.26) 694 (1527) 692 (1522) PN25 1185 (46.65) 819 (1802) 817 (1797) PN40 1250 (49.21) 1158 (2548) 1156 (2543) AS4087 PN35 1185 (46.65) 1044 (2297) 1042 (2292) ASME CL150 SERIES A 1170 (46.06) 961 (2114) 959 (2110) ASME CL150 SERIES B 1055 (41.54) 595 (1309) 593 (1305) ASME CL300 SERIES B 1170 (46.06) 1147 (2523) 1145 (2519) DN450 to 2400 (18 to 96 in. NB) (FEW) dimensions / weights (Continued) DS/WM–EN Rev. U 25 WaterMaster Electromagnetic flowmeter Dimensions in mm (in.) 104.5 98 (4.11) (3.86) 77.8 (3.06) 104 (4.1) 78 (3.1) 201 (7.91) 89 (3.5) E F G D C A L (1.0D) L (1.3D) …DN450 to 2400 (18 to 96 in. NB) (FEW) Dimensions in mm (in.) Approx. weight in kg (lb) DN Process connection type D L (1.0D) L (1.3D) F C E G A Integral Remote DN1000 (40 in.) JIS 5K 1195 (47.05) 554 (21.81) 679 (26.73) 639 (25.16) 624 (24.57) 441 (970) 439 (966) 1235 (48.62) 1300 (51.18) 755 (29.71) JIS 10K 1000 (39.37) 572 (1258) 570 (1254) PN6 1175 (46.26) 466 (1025) 464 (1021) PN10 1230 (48.43) 674 (1483) 672 (1478) PN16 1255 (49.41) 879 (1934) 877 (1929) AWWA C207 CLASS B 1289 (50.75) 503 (1107) 501 (1102) AWWA C207 CLASS D 1289 (50.75) 659 (1450) 657 (1445) AWWA C207 CLASS E 1289 (50.75) 1028 (2262) 1026 (2257) AWWA C207 CLASS F 1378 (54.25) 1367 (3007) 1365 (3003) AS4087 PN16 1255 (49.41) 831 (1828) 829 (1824) AS2129 TABLE-D 1255 (49.41) 610 (1342) 608 (1338) AS2129 TABLE-E 1255 (49.41) 833 (1833) 831 (1028) PN25 1320 (51.97) 1207 (2655) 1205 (2651) DN1050 (42 in.) DN1100 (44 in.) PN40 1360 (53.54) 1413 (3109) 1411 (3104) AS4087 PN35 1275 (50.20) 1244 (2737) 1242 (2732) ASME CL150 SERIES A 1290 (50.79) 1149 (2528) 1147 (2523) ASME CL300 SERIES A 1240 (48.82) 1349 (2968) 1347 (2963) ASME CL150 SERIES B 1175 (46.26) 738 (1624) 736 (1619) ASME CL300 SERIES B 1275 (50.20) 1487 (3271) 1485 (3267) AWWA C207 CLASS B 1346 (5299) AWWA C207 CLASS D 1346 (5299) 1050 (41.33) 1365 (53.74) 808 (31.82) 608 (23.92) 733 (28.84) 693 (27.28) 624 (24.57) 564 (1241) 562 (1236) 669 (1472) 667 (1467) AWWA C207 CLASS E 1346 (5299) 1143 (2515) 1141 (2510) AWWA C207 CLASS F 1448 (57.01) 1568 (3450) 1566 (3445) ASME CL150 SERIES B 1225 (48.23) 809 (1780) 807 (1775) ASME CL150 SERIES A 1345 (52.95) 1289 (2836) 1287 (2831) ASME CL300 SERIES A 1290 (50.79) 1527 (3359) 1525 (3355) ASME CL300 SERIES B 1335 (52.56) 1704 (3749) 1702 (3744) JIS 5K 1305 (51.38) 510 (1122) 508 (1118) JIS 10K 1345 (52.95) 689 (1516) 687 (1511) AWWA C207 CLASS B 1403 (55.24) 615 (1353) 613 (1349) AWWA C207 CLASS D 1403 (55.24) 807 (1775) 805 (1771) AWWA C207 CLASS E 1404 (55.26) 1205 (2651) 1203 (2647) AWWA C207 CLASS F 1505 (59.25) 1719 (3782) 1717 (3777) 1100 (43.30) 1430 (56.30) …DN450 to 2400 (18 to 96 in. NB) (FEW) dimensions / weights 26 DS/WM–EN Rev. U WaterMaster Electromagnetic flowmeter Dimensions in mm (in.) Approx. weight in kg (lb) DN Process connection type D L (1.0D) L (1.3D) F C E G A Integral Remote DN1200 (48 in.) JIS 5K 1420 (55.91) 659 (25.94) 784 (30.87) 744 (29.29) 802 (31.57) 651 (1432) 649 (1428) 1465 (57.68) 1560 (61.42) 860 (33.85) JIS 10K 1200 (47.24) 967 (2127) 965 (2123) PN6 1405 (55.31) 710 (1562) 708 (1558) PN10 1455 (57.28) 1107 (2435) 1105 (2431) DN1350 (54 in.) DN1400 (56 in.) DN1500 (60 in.) DN1600 (64 in.) PN16 1485 (58.46) 1363 (2999) 1361 (2994) AWWA C207 CLASS B 1511 (59.49) 772 (1698) 770 (1694) AWWA C207 CLASS D 1511 (59.49) 999 (2198) 997 (2193) AWWA C207 CLASS E 1511 (59.49) 1458 (3208) 1456 (3203) AWWA C207 CLASS F 1651 (65.00) 2400 (5280) 2398 (5276) AS4087 PN16 1490 (58.66) 1253 (2757) 1251 (2752) AS2129 TABLE-D 1490 (58.66) 1023 (2251) 1021 (2246) AS2129 TABLE-E 1490 (58.66) 1272 (2798) 1270 (2794) PN25 1530 (60.24) 1559 (3430) 1557 (3425) PN40 1575 (62.01) 2133 (4693) 2131 (4688) AS4087 PN35 1530 (60.24) 2115 (4653) 2113 (4649) ASME CL150 SERIES A 1510 (59.45) 1707 (3755) 1705 (3751) ASME CL300 SERIES A 1465 (57.68) 2163 (4759) 2161 (4754) ASME CL150 SERIES B 1390 (54.72) 1085 (2387) 1083 (2383) ASME CL300 SERIES B 1510 (59.45) 2352 (5174) 2350 (5170) AWWA C207 CLASS B 1683 (66.26) AWWA C207 CLASS D 1683 (66.26) 1820 (71.65) 754 (29.69) 879 (34.61) 839 (33.03) 902 (35.51 981 (2158) 979 (2154) 1213 (2669) 1211 (2664) 1942 (4272) 1940 (4268) 1085 (2387) 1083 (2383) 1731 (3808) 1729 (3804) 1683 (66.26) 1630 (64.17) PN10 1675 (65.94) PN16 1685 (66.34) 1770 (3894) 1768 (3890) ASME CL150 SERIES B 1600 (62.99) 1593 (3505) 1591 (3500) PN25 1755 (69.09) 2368 (5210) 2366 (5205) PN40 1795 (70.67) 3086 (6789) 3084 (6785) ASME CL150 SERIES A 1745 (68.70) 2556 (5623) 2554 (5619) ASME CL300 SERIES A 1710 (67.32) 3376 (7427) 3374 (7423) ASME CL300 SERIES B 1765 (69.49) 3758 (8268) 3756 (8263) JIS 5K 1730 (68.11) JIS 10K 1795 (70.67) ASME CL150 SERIES B AWWA C207 CLASS B 1029 (2264) 1027 (2259) 1504 (3309) 1502 (3304) 1725 (67.91) 2031 (4468) 2029 (4464) 1854 (72.99) 1229 (2704) 1227 (2699) AWWA C207 CLASS D 1854 (72.99) 1514 (3331) 1512 (3326) AWWA C207 CLASS E 1854 (72.99) 2544 (5597) 2542 (5592) ASME CL150 SERIES A 1855 (73.03) 3084 (6785) 3082 (6780) ASME CL300 SERIES A 1810 (71.26) 3875 (8525) 3873 (8521) ASME CL300 SERIES B 1880 (74.02 4181 (9198) 4179 (9194) PN6 1830 (72.05) 1500 (59.05) PN10 1915 (75.39) PN25 PN16 3201 (7042) 3199 (7038) 2768 (6090) 2766 (6085) PN40 2025 (79.72) 4375 (9625) 4373 (9621) DN1800 (72 in.) PN6 2045 (80.51) PN10 2115 (83.27) PN16 PN25 2340 (92.13) 1181 (46.50) 1502 (3304) 2025 (4455) 2023 (4451) 2130 (83.86) 3657 (8045) 3655 (8041) 2195 (86.42) 4422 (9728) 4420 (9724) AWWA C207 CLASS B 2197 (86.50) 1773 (3901) 1771 (3896) AWWA C207 CLASS D 2197 (86.50) 2387 (5251) 2385 (5247) AWWA C207 CLASS D 2362 (92.99) DN2000 (80 in.) PN6 2265 (89.17) PN10 2325 (91.54) 2309 (5080) 2307 (5075) 3037 (6681) 3035 (6677) 2581 (5678) 2579 (5674) 4254 (9359) PN16 4252 (9354) 2345 (92.32) 4556 4554 PN25 2425 (95.47) 5896 5894 AWWA C207 CLASS B 2534 (99.76) 2641 (5810) 2639 (5806) 3487 (7671) 3485 (7667) 3363 (7399) 3361 (7394) AWWA C207 CLASS D 2534 (99.76) PN6 2475 (97.44) PN10 2550 (100.39) PN6 2685 (105.71 PN10 2760 (108.66) N/A 2535 (99.80) 1090 (42.91) 1215 (47.83) 1175 (46.26) 1180 (46.46) 2600 (102.36) N/A 2730 (107.48) N/A 2860 (112.60) N/A 1291 (50.81) 1100 (43.31) 1504 (3309) 1851 (4072) N/A 1065 (41.93) 1000 (39.37) 3178 (6992) 2362 (92.99) 1105 (43.50) 1000 (39.37) 1853 (4077) AWWA C207 CLASS B 980 (38.58) 1040 (40.94) 1000 (39.37) 3180 (6996) DN1950 (78 in.) N/A 915 (36.02) 950 (37.4) 910 (35.83) 1930 (75.98) 1116 (43.94) 990 (38.98) 949 (37.36) 1975 (77.76) 2145 (84.45) 865 (34.06) 989 (38.94) 1432 (3150) 2032 (80.00) 1066 (41.96) 864 (34.02) 2523 (5551) N/A 2080 (81.89) 1065 (41.92) 2525 (5555) AWWA C207 CLASS D 1600 (62.99) 1950 (76.77) 1434 (3155) 2032 (80.00) DN2400 (96 in.) 1400 (55.11) 955 (37.59) PN6 AWWA C207 CLASS B DN2200 (88 in.) 1755 (69.09) AWWA C207 CLASS E DN1650 (66 in.) DN2100 (84 in.) 1350 (53.15) 3120 (122.83) 1395 (54.91) 1194 (47.01) 1319 (51.93) 1279 (50.35) 1180 (46.46) 1330 (52.36) 1495 (58.85) 1294 (50.94) 1419 (55.87) 1379 (54.29) 1450 (57.09) 5795 5793 4100 (9020) 4098 (9016) 6968 6966 …DN450 to 2400 (18 to 96 in. NB) (FEW) dimensions / weights (Continued) DS/WM–EN Rev. U 27 WaterMaster Electromagnetic flowmeter FEV – DN40 to 200 (11/2 to 8 in. NB) Dimensions in mm (in.) 77.8 (3.06) 98 (3.86) Ø104 (4.1) F 78 (3.1) 201 (7.91) 89 (3.5) 104.5 (4.11) E G X D C X L DN40 to 200 (11/2 to 8 in. NB) (FEV) DN DN40 (11/2 in.) DN50 (2 in.) DN80 (3 in.) DN100 (4 in.) DN150 (6 in.) DN200 (8 in.) Process connection type EN1092-1 PN10, 16, 25, 40 ASME B16.5 CLASS 150 AS2129 TABLE D, E, F EN1092-1 PN10, 16, 25, 40 ASME B16.5 CLASS 150 EN1092-1 PN10, 16, 25, 40 ASME B16.5 CLASS 150 AS4087 PN16, 21 AS2129 TABLE D, E, F EN1092-1 PN10, 16, 25, 40 ASME B16.5 CLASS 150 AS4087 PN16 EN1092-1 PN10, 16, 25, 40 ASME B16.5 CLASS 150 AS4087 PN16 EN1092-1 PN10, 16 ASME B16.5 CLASS 150 AS2129 TABLE C, D, E, F AS4087 PN14, 16, 21 D 150 (5.91) L 200 (7.87) Dimensions in mm (in.) F E 260 (10.24) 185 (7.28) G 137 (5.39) X 30 (1.18) Approx. weight in kg (lb) Integral Remote 12.8 (28.16) 11.8 (25.96) 165 (6.50) 200 (7.87) 261 (10.28) 186 (7.32) 138 (5.43) 38 (1.5) 13.75 (30.25) 12.75 (28.05) 200 (7.87) 200 (7.87) 280 (11.04) 205.5 (8.09) 157.5 (6.2) 61 (2.4) 17.2 (37.84) 16.2 (35.64) 225 (8.86) 250 (9.84) 300.5 (11.83) 225.5 (8.88) 177.5 (6.98) 70 (2.76) 19.3 (42.5) 18.3 (40.3) 300 (11.81) 300 (11.81) 333.5 (13.13) 258.5 (10.18) 210.5 (8.29) 103 (4.06) 35.1 (77.2) 34.1 (75) 375 (11.76) 350 (13.78) 358.7 (14.12) 283.7 (11.17) 235.7 (9.28) 150 (5.91) 67 (147.4) 66 (145.2) WaterMaster integral / remote FEV – DN40 to 200 (11/2 to 8 in.) cast iron sensor dimensions / weights 28 DS/WM–EN Rev. U WaterMaster Electromagnetic flowmeter Dimensions in mm (in.) Approx. weight in kg (lb) DN Process connection type D L F C E G X Integral Remote DN40 (11/2 in.) EN1092-1 PN10, PN40 150 (5.91) 200 (7.87) 260 (10.24) 30.4 (1.20) 185 (7.28) 138 (5.43) 30 (1.18) 12 (27) 11 (24) ASME B16.5 CLASS 150 127 (5.00) JIS 10K 140 (5.51) 200 (7.87) 270 (10.63) 38.3 (1.51) 195 (7.68) 146 (5.75) 38 (1.50) 13 (29) 12 (27) 200 (7.87) 275 (10.83) 45.2 (1.78) 200 (7.87) 152 (5.98) 48 (1.89) 15 (33) 14 (31) 200 (7.87) 280 (11.02) 51.5 (2.03) 205 (8.07) 156 (6.14) 61 (2.40) 16 (36) 15 (33) 250 (9.84) 320 (12.60) 63.75 (2.51) 245 (9.65) 196.8 (7.75) 70 (2.76) 19 (42) 18 (40) 250 (9.84) 320 (12.60) 63.75 (2.51) 245 (9.65) 197 (7.76) 70 (2.76) 20 (44) 19 (42) 300 (11.81) 340 (13.39) 84.4 (3.32) 265 (10.43) 217 (8.54) 103 (4.06) 32 (70) 31 (68) 350 (13.78) 365 (14.37) 109.8 (4.32) 290 (11.42) 243 (9.57) 150 (5.91) 49 (108) 48 (105) DN50 (2 in.) DN65 (21/2 in.) DN80 (3 in.) DN100 (4 in.) DN125 (5 in.) DN150 (6 in.) DN200 (8 in.) AS2129 TABLE F 140 (5.51) AS2129 TABLE C D E 135 (5.31) AS4087 PN14 135 (5.31) EN1092-1 PN10, PN16 165 (6.50) ASME B16.5 CLASS 150 152.4 (6.00) JIS 10K 155 (6.10) AS4087 PN21 165 (6.50) AS2129 TABLE F 165 (6.50) AS2129 TABLE C D E 150 (5.91) AS4087 PN14, PN16 150 (5.91) AS4087 PN14, PN16 165 (6.50) AS2129 TABLE C D E 165 (6.50) EN1092-1 PN10 185 (7.28) EN1092-1 PN16 185 (7.28) EN1092-1 PN10, PN16 200 (7.87) ASME B16.5 CLASS 150 190 (7.48) JIS 7.5K 211 (8.31) JIS 10K 185 (7.28) AS2129 TABLE C D E 185 (7.28) AS4087 PN14, PN16 185 (7.28) AS2129 TABLE F 205 (8.07) AS4087 PN21 205 (8.07) EN1092-1 PN10, PN16 220 (8.66) ASME B16.5 CLASS 150 228.6 (9.00) JIS 7.5K 238 (9.37) JIS 10K 210 (8.27) AS2129 TABLE C D 215 (8.46) AS4087 PN14, PN16 215 (8.46) AS2129 TABLE E 215 (8.46) AS4087 PN21 230 (9.06) AS2129 TABLE F 230 (9.06) EN1092-1 PN10, PN16 250 (9.84) ASME B16.5 CLASS 150 254 (10.00) JIS 10K 250 (9.84) AS2129 TABLE C D E 255 (10.04) AS2129 TABLE F 280 (11.02) EN1092 PN10, PN16 285 (11.22) ASME B16.5 CLASS 150 279 (10.98) JIS 7.5k 290 (11.42) JIS 10K 280 (11.02) AS2129 TABLE C D 280 (11.02) AS4087 PN14, PN16 280 (11.02) AS2129 TABLE E 280 (11.02) AS2129 TABLE F 305 (12.01) AS4087 PN21 305 (12.01) EN1092-1 PN10 340 (13.39) EN1092-1 PN16 340 (13.39) ASME B16.5 CLASS 150 345 (13.58) JIS 7.5K 342 (13.46) JIS 10K 330 (12.99) AS2129 TABLE C D 335 (13.19) AS4087 PN14, PN 16 335 (13.19) AS2129 TABLE E 335 (13.19) AS2129 TABLE F 370 (14.57) AS4087 PN21 370 (14.57) 1 DN40 to 200 (1 /2 to 8 in. NB) (FEV) dimensions / weights DS/WM–EN Rev. U 29 WaterMaster Electromagnetic flowmeter FER – DN40 to 300 (11/2 to 12 in. NB) Dimensions in mm (in.) 77.8 (3.06) 98 (3.86) Ø104 (4.1) F 78 (3.1) 201 (7.91) 89 (3.5) 104.5 (4.11) E G X D C X L DN40 to 300 (11/2 to 12 in. NB) (FER) DN DN40 (11/2 in.) DN50 (2 in.) DN80 (3 in.) DN100 (4 in.) DN150 (6 in.) DN200 (8 in.) Process connection type EN1092-1 PN10, 16, 25, 40 ASME B16.5 CLASS 150 AS2129 TABLE D, E, F EN1092-1 PN10, 16, 25, 40 ASME B16.5 CLASS 150 EN1092-1 PN10, 16, 25, 40 ASME B16.5 CLASS 150 AS4087 PN16, 21 AS2129 TABLE D, E, F EN1092-1 PN10, 16, 25, 40 ASME B16.5 CLASS 150 AS4087 PN16 EN1092-1 PN10, 16, 25, 40 ASME B16.5 CLASS 150 AS4087 PN16 EN1092-1 PN10, 16 ASME B16.5 CLASS 150 AS2129 TABLE C, D, E, F AS4087 PN14, 16, 21 D 150 (5.91) L 200 (7.87) Dimensions in mm (in.) F E 260 (10.24) 185 (7.28) G 137 (5.39) X 23.5 (0.93) 165 (6.50) 200 (7.87) 261 (10.28) 186 (7.32) 138 (5.43) 29 (1.14) 14.75 (32.45) 13.75 (30.25) 200 (7.87) 200 (7.87) 280 (11.04) 205.5 (8.09) 157.5 (6.2) 47 (1.85) 21.2 (46.64) 20.2 (44.4) 225 (8.86) 250 (9.84) 300.5 (11.83) 225.5 (8.88) 177.5 (6.98) 64 (2.52) 27.3 (60) 26.3 (58) 300 (11.81) 300 (11.81) 333.5 (13.13) 258.5 (10.18) 210.5 (8.29) 100.2 (3.94) 27.3 (60) 26.3 (58) 375 (11.76) 350 (13.78) 358.7 (14.12) 283.7 (11.17) 235.7 (9.28) 126.7 (5.00) 68 (150) 67 (147.4) DN40 to 200 (11/2 to 8 in.) (FER) cast iron sensor dimensions / weights 30 DS/WM–EN Rev. U Approx. weight in kg (lb) Integral Remote 13.4 (29.5) 12.4 (27.3) WaterMaster Electromagnetic flowmeter DN DN40 1 (1 /2 in.) DN50 (2 in.) DN65 (21/2 in.) DN80 (3 in.) DN100 (4 in.) DN125 (5 in.) DN150 (6 in.) DN200 (8 in.) DN250 (10 in.) DN300 (12 in.) Process connection type EN1092-1 PN10, 16, 25, 40 ASME B16.5 CLASS 150 JIS 10K AS2129 TABLE C D E AS2129 TABLE F AS4087 PN14 EN1092-1 PN10, 16, 25, 40 ASME B16.5 CLASS 150 JIS 10K AS4087 PN21 AS2129 TABLE F AS2129 TABLE C D E AS4087 PN14, PN16 EN1092-1 PN10, 16, 25, 40 ASME B16.5 CLASS 150 JIS10K AS2129 TABLE C D E AS2129 TABLE F AS4087 PN14, 16 AS4087 PN21 EN1092-1 PN10, 16, 25, 40 ASME B16.5 CLASS 150 JIS 10K AS2129 TABLE C D E AS4087 PN14, 16 AS2129 TABLE F AS4087 PN21 EN1092-1 PN10, 16 EN1092-1 PN25, 40 ASME B16.5 CLASS 150 JIS 7.5K JIS 10K AS2129 TABLE C D AS4087 PN14, 16 AS4087 PN21 EN1092-1 PN10, 16 EN1092-1 PN25, 40 ASME B16.5 CLASS 150 JIS 10K AS2129 TABLE C D EN1092 PN10, 16 EN1092 PN25, 40 ASME B16.5 CLASS 150 JIS 7.5k JIS 10K AS2129 TABLE C D AS4087 PN14, 16 AS4087 PN21 EN1092-1 PN10, 16 EN1092-1 PN25, 40 ASME B16.5 CLASS 150 JIS 7.5K JIS 10K AS2129 TABLE C D AS4087 PN14, 16 AS4087 PN21 EN1092-1 PN10 EN1092-1 PN16 EN1092-1 PN25 ASME B16.5 CLASS 150 JIS 7.5K JIS 10K AS2129 TABLE C D AS4087 PN14, 16 AS4087 PN21 EN1092-1 PN10 EN1092-1 PN16 EN1092-1 PN25 ASME B16.5 CLASS 150 JIS 10K AS2129 TABLE C D AS4087 PN14, 16 AS4087 PN21 D 150 (5.91) 127 (5.00) 140 (5.51) 135 (5.31) 140 (5.51) 135 (5.31) 165 (6.50) 152.4 (6.00) 155 (6.10) 165 (6.50) 165 (6.50) 150 (5.91) 150 (5.91) 185 (7.28) 178 (7.00) 175 (6.89) 165 (6.50) 185 (7.28) 165 (6.50) 185 (7.28) 200 (7.87) 190 (7.48) 185 (7.28) 185 (7.28) 185 (7.28) 205 (8.07) 205 (8.07) 220 (8.66) 235 (9.25) 228.6 (9.00) 238 (9.37) 210 (8.27) 215 (8.46) 215 (8.46) 230 (9.06) 250 (9.84) 270 (10.63) 254 (10.00) 250 (9.84) 255 (10.04) 285 (11.22) 300 (11.81) 279 (10.98) 290 (11.42) 280 (11.02) 280 (11.02) 280 (11.02) 305 (12.01) 340 (13.39) 360 (14.17) 345 (13.58) 342 (13.46) 330 (12.99) 335 (13.19) 335 (13.19) 370 (14.57) 395 (15.55) 405 (15.94) 425 (16.73) 405 (15.94) 400 (15.75) 400 (15.75) 405 (15.94) 405 (15.94) 430 (16.93) 445 (17.52) 460 (18.11) 485 (19.09) 485 (19.09) 445 (17.52) 455 (17.91) 455 (17.91) 490 (19.29) L 200 (7.87) Dimensions in mm (in.) F C E 260 (10.24) 30.4 (1.20) 185 (7.28) G 138 (5.43) X 23.5 (0.93) Approx. weight in kg (lb) Integral Remote 13 (29) 11 (24) 200 (7.87) 270 (10.63) 38.3 (1.51) 195 (7.68) 146 (5.75) 29 (1.14) 14 (31) 12 (27) 200 (7.87) 275 (10.83) 45.2 (1.78) 200 (7.87) 152 (5.98) 37 (1.46) 15 (33) 13 (29) 200 (7.87) 280 (11.02) 51.5 (2.03) 205 (8.07) 156 (6.14) 47 (1.85) 20 (44) 18 (40) 250 (9.84) 320 (12.60) 63.75 (2.51) 245 (9.65) 196.8 (7.75) 64 (2.52) 27 (59) 25 (55) 250 (9.84) 320 (12.60) 63.75 (2.51) 245 (9.65) 197 (7.76) 64 (2.52) 27 (59) 25 (55) 300 (11.81) 340 (13.39) 84.4 (3.32) 265 (10.43) 217 (8.54) 100.2 (3.94) 33 (72) 31 (68) 350 (13.78) 365 (14.37) 109.8 (4.32) 290 (11.42) 243 (9.57) 126.7 (4.99) 50 (110) 48 (106) 450 (17.72) 389 (15.31) 136.8 (5.39) 313 (12.33) 268 (10.55) 153.5 (6.04) 77 (169) 75 (165) 500 (19.69) 414 (16.30) 162.2 (6.39) 338.6 (13.33) 294 (1157) 203.5 (8.01) 114 (251) 112 (247) DN40 to 300 (11/2 to 12 in. NB) (FER) dimensions / weights DS/WM–EN Rev. U 31 WaterMaster Electromagnetic flowmeter FER – DN350 to 600 (14 to 24 in. NB) remote sensor Dimensions in mm (in.) Ø104 (4.1) 86 (3.4) G D C X A L DN350 to 600 (14 to 24 in. NB) (FER) remote sensor 32 DS/WM–EN Rev. U WaterMaster Electromagnetic flowmeter Dimensions in mm (in.) Approx. weight in kg (lb) DN Process connection type D L F C E G A X Remote DN350 (14 in.) EN1092-1 PN10 505 (19.88) 550 (21.65) 472 (18.58) 231 (9.09) 402 (15.83) 325 (12.80) 376 (14.80) 340 (13.39) 100 (220) EN1092-1 PN16 520 (20.47) EN1092-1 PN25 555 (21.85) 600 (23.62) 502 (19.76) 257.5 (10.14) 432 (17.01) 355 (13.98) 420 (16.54) 390 (15.35) 115 (253) 700 (27.56) 537 (21.14) 285 (11.22) 467 (18.39) 390 (15.35) 480 (18.90) 440 (17.32) 160 (352) 770 (30.31) 557 (21.93) 317.5 (12.50) 487 (19.17) 410 (16.14) 520 (20.47) 490 (19.29) 217 (477) 920 (36.22) 602 (23.70) 345 (13.58) 532 (20.94) 455 (17.91) 610 (24.02) 591 (23.27) 315 (693) DN400 (16 in.) DN450 (18 in.) DN500 (20 in.) DN600 (24 in.) EN1092-1 PN40 580 (22.83) JIS 5K 480 (18.90) JIS 10K 490 (19.29) AS2129 TABLE C D E 525 (20.67) AS2129 TABLE F 550 (21.65) AS4087 PN14, PN16 525 (20.67) AS4087 PN21 550 (21.65) EN1092-1 PN10 565 (22.24) EN1092-1 PN16 580 (22.83) EN1092-1 PN25 620 (24.41) EN1092-1 PN40 660 (25.98) JIS 5K 540 (21.26) JIS 10K 560 (22.05) AS2129 TABLE C D E 580 (22.83) AS2129 TABLE F 610 (24.02) AS4087 PN14, PN16 580 (22.83) AS4087 PN21 610 (24.02) EN1092-1 PN10 615 (24.21) EN1092-1 PN16 640 (25.20) EN1092-1 PN25 670 (26.38) EN1092-1 PN40 685 (26.97) JIS 5K 605 (23.82) JIS 10K 620 (24.41) AS2129 TABLE C D E 640 (25.20) AS2129 TABLE F 675 (26.57) AS4087 PN14, PN16 640 (25.20) AS4087 PN21 675 (26.57) EN1092-1 PN10 670 (26.38) EN1092-1 PN16 715 (28.15) EN1092-1 PN25 730 (28.74) EN1092-1 PN40 755 (29.72) JIS 5K 655 (25.79) JIS 10K 675 (26.57) AS2129 TABLE C D E 705 (27.76) AS2129 TABLE F 735 (28.94) AS4087 PN14, PN16 705 (27.76) AS4087 PN21 735 (28.94) EN1092-1 PN10 780 (30.71) EN1092-1 PN16 840 (33.07) EN1092-1 PN25 845 (33.27) EN1092-1 PN40 890 (35.04) JIS 5K 770 (30.31) JIS 10K 795 (31.30) AS2129 TABLE C D E 825 (32.48) AS2129 TABLE F 850 (33.46) AS4087 PN14, PN16 825 (32.48) AS4087 PN21 850 (33.46) DN350 to 600 (14 to 24 in. NB) (FER) remote sensor dimensions / weights DS/WM–EN Rev. U 33 WaterMaster Electromagnetic flowmeter FEF – DN250 to 600 (10 to 24 in. NB) Dimensions in mm (in.) Ø104 (4.1) 86 (3.4) G D C X *Base A L *Dimension C = centre line to base of flowmeter body DN250 to 600 (10 to 24 in. NB) (FEF) 34 DS/WM–EN Rev. U WaterMaster Electromagnetic flowmeter Dimensions in mm (in.) DN Process connection type D L C G A X Approx. weight in kg (lb) DN250 (10 in.) ASME B16.5 CLASS 150 405 (15.94) 450 (17.72) 215 (8.46) 301 (11.85) 300 (11.81) 250 (9.84) 88 (194) ASME B16.5 CLASS 300 445 (17.52) 490 (19.29) 450 (17.72) 231 (9.09) 317 (12.48) 352 (13.86) 300 (11.81) 128 (282) 257.5 (10.14) 346 (13.62) 376 (14.80) 350 (13.78) 100 (220) 257.5 (10.14) 346 (13.62) 376 (14.80) 350 (13.78) 115 (253) 285 (11.22) 371 (14.61) 420 (16.54) 400 (15.75) 115 (253) EN1092 -1 PN10 395 (15.55) EN1092 – 1 PN16 405 (15.94) EN1092 – 1 PN25 425 (16.73) EN1092 – 1 PN40 450 (17.72) JIS 5K 385 (15.16) JIS 10K 400 (15.75) AS4087 PN14, PN16 405 (15.94) 490 (19.29) 450 (17.72) AS2129 TABLE C D AS2129 TABLE E AS4087 PN21 430 (16.93) AS2129 TABLE F DN300 (12 in.) DN350 (14 in.) ASME B16.5 CLASS 150 485 (19.09) 500 (19.69) ASME B16.5 CLASS 300 520 (20.47) 540 (21.26) EN1092 – 1 PN10 445 (17.52) 500 (19.69) EN1092 – 1 PN16 460 (18.11) 500 (19.69) EN1092 – 1 PN25 485 (19.09) 540 (21.26) EN1092 – 1 PN40 515 (20.28) 540 (21.26) JIS 5K 430 (16.93) 500 (19.69) JIS 10K 445 (17.52) 500 (19.69) AS4087 PN14, PN16 455 (17.91) 500 (19.69) AS2129 TABLE TABLE C D 455 (17.91) 500 (19.69) AS2129 TABLE E 455 (17.91) 500 (19.69) AS4087 PN21 490 (19.29) 500 (19.69) AS2129 TABLE F 490 (19.29) 500 (19.69) ASME B16.5 CLASS 150 535 (21.06) 550 (21.65) ASME B16.5 CLASS 300 585 (23.03) 570 (22.44) EN1092 – 1 PN10 505 (19.88) 550 (21.65) EN1092 – 1 PN16 520 (20.47) 550 (21.65) EN1092 – 1 PN25 555 (21.85) 570 (22.44) EN1092 – 1 PN40 580 (22.83) 570 (22.44) JIS 5K 480 (18.90) 550 (21.65) JIS 7.5K 530 (20.87) 550 (21.65) JIS 10K 490 (19.29) 550 (21.65) AS4087 PN14, PN16 525 (20.67) 550 (21.65) AS2129 TABLE C D E 525 (20.67) 550 (21.65) AS4087 PN21 550 (21.65) 550 (21.65) AS2129 TABLE F 550 (21.65) 550 (21.65) AS4087 PN35 550 (21.65) 570 (22.44) AS2129 TABLE H 550 (21.65) 570 (22.44) DN375 (15 in.) AS4087 PN14, PN16 550 (21.65) 550 (21.65) AS2129 TABLE C 550 (21.65) 550 (21.65) AS4087 PN35 580 (22.83) 570 (22.44) DN400 (16 in.) ASME B16.5 CLASS 150 600 (23.62) 600 (23.62) ASME B16.5 CLASS 300 650 (25.59) 620 (24.41) EN1092 – 1 PN10 565 (22.24) 600 (23.62) EN1092 – 1 PN16 580 (22.83) 600 (23.62) EN1092 – 1 PN25 620 (24.41) 620 (24.41) EN1092 – 1 PN40 660 (25.98) 620 (24.41) JIS 5K 540 (21.26) 600 (23.62) JIS 7.5K 582 (22.91) 600 (23.62) JIS 10K 560 (22.05) 600 (23.62) AS4087 PN14, PN16 580 (22.83) 600 (23.62) AS2129 TABLE C D E 580 (22.83) 600 (23.62) 600 (23.62) AS4087 PN21 610 (24.02) AS2129 TABLE F 610 (24.02) 600 (23.62) AS4087 PN35 610 (24.02) 620 (24.41) AS2129 TABLE H 610 (24.02) 620 (24.41) DN250 to 600 (10 to 24 in. NB) (FEF) dimensions / weights DS/WM–EN Rev. U 35 WaterMaster Electromagnetic flowmeter Dimensions in mm (in.) Ø104 (4.1) 86 (3.4) G D C X *Base A L *Dimension C = centre line to base of flowmeter body …DN250 to 600 (10 to 24 in. NB) (FEF) 36 DS/WM–EN Rev. U WaterMaster Electromagnetic flowmeter Dimensions in mm (in.) DN Process connection type D L C G A X Approx. weight in kg (lb) DN450 (18 in.) ASME B16.5 CLASS 150 635 (25.00) 700 (27.56) 317.5 (12.50) 402 (15.83) 480 (18.90) 450 (17.72) 160 (352) ASME B16.5 CLASS 300 710 (27.95) EN1092 – 1 PN10 615 (24.21) EN1092 – 1 PN16 640 (25.20) EN1092 – 1 PN25 670 (26.38) 770 (30.31) 345 (13.58) 429 (16.89) 520 (20.47) 500 (19.69) 217 (455) 920 (36.22) 387.5 (15.25) 472 (18.58) 610 (24.02) 600 (23.62) 315 (693) DN500 (20 in.) DN600 (24 in.) EN1092 – 1 PN40 685 (26.97) JIS 5K 605 (23.82) JIS 7.5K 652 (25.67) JIS 10K 620 (24.41) AS4087 PN14, PN16 640 (25.20) AS2129 TABLE C D 640 (25.20) AS2129 TABLE E 640 (25.20) AS4087 PN21 675 (26.57) AS2129 TABLE F 675 (26.57) AS4087 PN35 675 (26.57) AS2129 TABLE H 675 (26.57) ASME B16.5 CLASS 150 700 (27.56) ASME B16.5 CLASS 300 775 (30.51) EN1092 – 1 PN10 670 (26.38) EN1092 – 1 PN16 715 (28.15) EN1092 – 1 PN25 730 (28.74) EN1092 – 1 PN40 755 (29.72) JIS 5K 655 (25.79) JIS 7.5K 706 (27.80) JIS 10K 675 (26.57) AS4087 PN 14, PN16 705 (27.76) AS2129 TABLE C D E 705 (27.76) AS4087 PN21 735 (28.94) AS2129 TABLE F 735 (28.94) AS4087 PN35 735 (28.94) AS2129 TABLE H 735 (28.94) ASME B16.5 CLASS 150 815 (32.09) ASME B16.5 CLASS 300 915 (36.02) EN1092 – 1 PN10 780 (30.71) EN1092 – 1 PN16 840 (33.07) EN1092 – 1 PN25 845 (33.27) EN1092 – 1 PN40 890 (35.04) JIS 5K 770 (30.31) JIS 7.5K 810 (31.89) JIS 10K 795 (31.30) AS4087 PN14, PN16 825 (32.48) AS2129 TABLE C D 825 (32.48) AS2129 TABLE E 825 (32.48) AS4087 PN21 850 (33.46) AS2129 TABLE F 850 (33.46) AS4087 PN35 850 (33.46) AS2129 TABLE H 850 (33.46) …DN250 to 600 (10 to 24 in. NB) (FEF) dimensions / weights DS/WM–EN Rev. U 37 WaterMaster Electromagnetic flowmeter Ordering information Electromagnetic flowmeter WaterMaster – FEW11, FEW12 and FEW18 FEW11 Flowmeter system – full bore, remote mount FEW12 Full bore sensor only – for use with WaterMaster transmitter / remote FEW18 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27 X XXX X X X X XX X X X X X X X X X X X X Design Non-hazardous areas Hazardous areas 1 5 Bore diameter DN10 (3/8 in.) DN15 (1/2 in.) DN20 (3/4 in.) DN25 (1 in.) DN32 (11/4 in.) 010 015 020 025 032 Liner material PTFE – DN10 to 32 (3/8 to 11/4 in. NB) A Electrode design Standard Other 1 9 Measuring electrodes material Hastelloy® C-4 (2.4610) D Grounding accessories Not required One potential equalizing ring (stainless steel) Two potential equalizing rings (stainless steel) Other 0 3 4 9 Process connection type (refer to pages 21 and 20) ASME B16.5 B class 150 ASME B16.5 B class 300 ISO / EN PN40 DIN PN40 Other A1 A3 S4 D4 Z9 Process connection material Carbon steel flanges – DN20 to 32 (3/4 to 11/4 in. NB) Stainless steel flange 1.4571 (316 Ti) – DN10 to 15 (3/8 to 1/2 in. NB) Other B D Z Usage certifications Standard (without PED) Other 1 9 Calibration type Class 2 calibration – standard accuracy 0.4 % Class 1 calibration – high accuracy 0.2 % Extended range, class 1 calibration – high accuracy 0.2 % Extended range, class 2 calibration – standard accuracy 0.4 % A B N P Temperature range installation / ambient temperature range Standard design / –20 … 60 °C (–4 … 140 °F) 1 Nameplate Adhesive A Signal cable length and type Without signal cable 5 m (15 ft.) cable 10 m (30 ft.) cable 20 m (60 ft.) cable 30 m (100 ft.) cable 50 m (165 ft.) cable 80 m (260 ft.) cable 100 m (325 ft.) cable 150 m (490 ft.) cable Special length or cable type 0 1 2 3 4 5 6 7 8 9 Explosion protection certification General purpose (non-Ex design) FM Class 1 Div. 2 usFMc Class 1 Div. 2 ATEX / IECEx Zone 2, 21 & 22 A G P M Continued on next page… 38 DS/WM–EN Rev. U Options Product coding field number 1 … 5 Flowmeter system – full bore, integral mount (DN10 to DN32 only) WaterMaster Electromagnetic flowmeter 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27 X XXX X X X X XX X X X X X X X X X X X X FEW11 Flowmeter system – full bore, remote mount FEW12 Full bore sensor only – for use with WaterMaster transmitter / remote FEW18 Options Product coding field number 1 … 5 Flowmeter system – full bore, integral mount (DN10 to DN32 only) Protection class transmitter / protection class sensor IP67 (NEMA 4X) / IP67 (NEMA 4X) – cable not fitted and potted to sensor IP67 (NEMA 4X) / IP67 (NEMA 4X) – cable fitted and potted to sensor 1 7 Cable conduits* M20 x 1.5 (plastic) NPT 1/2 in. (blanked when cable not fitted) M20 SWA (armored) M20 SWA sensor, M20 x 1.5 (plastic) power / output Without A B D F Y Power supply Without 100... 230 V AC, 50 Hz 24 V AC or 24 V DC, 50 Hz 100... 230 V AC, 60 Hz 24 V AC or 24 V DC, 60 Hz 0 1 2 3 4 Input and output signal type HART + 20 mA + pulse + contact output PROFIBUS DP RS485 physical layer + pulse + contact output (general-purpose design only) MODBUS RTU RS485 physical layer + pulse + contact output (general-purpose design only) Without A G M Y Configuration type / diagnostics type Not required Factory default/ standard 0 1 Options** Accessories Configuration lead AC Documentation language German Italian Spanish French English M1 M2 M3 M4 M5 (default) Chinese Swedish Finnish Portuguese Danish Norwegian M6 M7 M8 MA MF MN Verification type Without fingerprint VeriMaster V0 V3 Potable water approval WRAS cold water approval Without CWA CWY Power supply frequency (FEW 18 only) 50 Hz 60 Hz F5 F6 Number of testpoints (FEW 10 to 32 only) 1 Point 3 Points T1 T3 * For FM or FMC Approved versions, NPT only permitted. ** Add codes for options. DS/WM–EN Rev. U 39 WaterMaster Electromagnetic flowmeter Electromagnetic flowmeter WaterMaster FEV11, FEV12 and FEV18 FEV11 Flowmeter system, optimized full bore, remote mount FEV12 Optimized full bore sensor only, for use with WaterMaster transmitter / remote FEV18 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27 X XXX X X X X XX X X X X X X X X X X X X Design Non-hazardous areas Hazardous areas 1 5 Bore diameter DN40 (11/2 in.) DN50 (2 in.) DN65 (21/2 in.) DN80 (3 in.) DN100 (4 in.) DN125 (5 in.) DN150 (6 in.) DN200 (8 in.) 040 050 065 080 100 125 150 200 Liner material Polypropylene – DN40 to 200 (11/2 to 8 in. NB) V Electrode design Standard 1 Measuring electrodes material Stainless steel 316 Hastelloy® C-22 Super-austenitic steel S C U Grounding accessories Standard One potential equalizing ring (stainless steel) Two potential equalizing rings (stainless steel) 1 3 4 Process connection type (refer to pages 29 and 28) Flanges ASME B16.5 class 150 Flanges AS 4087 PN21 (DN50 [2 in. NB]) Flanges AS 4087 PN16 ( DN50 [2 in. NB]) Flanges AS 4087 PN14 Flanges AS 2129 Table F Flanges AS 2129 Table E Flanges AS 2129 Table D Flanges AS 2129 Table C Flanges JIS G5527 7.5K (³ DN100 [4 in. NB]) Flanges JIS B2220 10K ISO/EN PN10 ISO / EN PN16 ( DN50 [2 in. NB]) ISO / EN PN40 (DN40 [11/2 in. NB] only) 16 bar rated A1 E0 E1 E2 E3 E4 E5 E6 J0 J1 S1 S2 S4 Process connection material Carbon steel flanges B Usage certifications Standard 1 Calibration type Class 2 Calibration – standard accuracy 0.4 % Class 1 Calibration – high accuracy 0.2 % Extended range, class 1 calibration – high accuracy 0.2 % Extended range, class 2 calibration – standard accuracy 0.4 % A B N P Continued on next page… 40 DS/WM–EN Rev. U Options Product coding field number 1 … 5 Flowmeter system, optimized full bore, integral mount WaterMaster Electromagnetic flowmeter 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27 X XXX X X X X XX X X X X X X X X X X X X FEV11 Flowmeter system, optimized full bore, remote mount FEV12 Optimized full bore sensor only, for use with WaterMaster transmitter / remote FEV18 Options Product coding field number 1 … 5 Flowmeter system, optimized full bore, integral mount Temperature range installation / ambient temperature range Standard design / –20 … 60 °C (–4 … 140 °F) 1 Nameplate Adhesive A Signal cable length and type* Without signal cable 5 m (15 ft.) cable 10 m (30 ft.) cable 20 m (60 ft.) cable 30 m (100 ft.) cable 50 m (165 ft.) cable 80 m (260 ft.) cable 100 m (325 ft.) cable 150 m (490 ft.) cable Special length > 150 m (> 490 ft.) 0 1 2 3 4 5 6 7 8 9 Explosion protection certification General purpose (non-Ex design) FM Class 1 Div. 2 usFMc Class 1 Div. 2 ATEX / IECEx Zone 2, 21 & 22 A G P M Protection class transmitter / protection class sensor IP67 (NEMA 4X) / IP67 (NEMA 4X) – integral IP67 (NEMA 4X) / IP68 (NEMA 6P) – cable not fitted and not potted IP67 (NEMA 4X) / IP68 (NEMA 6P) – cable fitted and potted 1 2 3 Cable conduits * M20 x 1.5 (plastic) NPT 1/2 in. (blanked when cable not fitted) M20 SWA (armored) M20 SWA sensor, M20 x 1.5 (plastic) power / output Without A B D F Y Power supply Without 100... 230 V AC, 50 Hz 24 V AC or 24 V DC, 50 Hz 100... 230 V AC, 60 Hz 24 V AC or 24 V DC, 60 Hz Others 0 1 2 3 4 9 Input and output signal type HART + 20 mA + pulse + contact output PROFIBUS DP RS485 physical layer + pulse + contact output (general-purpose design only) MODBUS RTU RS485 physical layer + pulse + contact output (general-purpose design only) Without A G M Y Configuration type / diagnostics type Without Factory defaults / standard diagnostics 0 1 Continued on next page… * The type of signal cable supplied (standard or armored) depends on the type of cable conduit (variant digit number 24) ordered. For FM or FMC Approved versions, NPT only permitted. DS/WM–EN Rev. U 41 WaterMaster Electromagnetic flowmeter Flowmeter system, optimized full bore, remote mount FEV12 Optimized full bore sensor only, for use with WaterMaster transmitter / remote FEV18 Options** Accessories Configuration lead AC Documentation language German Italian Spanish French English M1 M2 M3 M4 M5 (default) Chinese Swedish Finnish Portuguese Danish Norwegian M6 M7 M8 MA MF MN Other usage certifications Measuring Instruments Directive (MID) OIML R49 Calibration CM1 CM2 Verification type Without fingerprint VeriMaster V0 V3 Potable water approval WRAS cold water approval NSF 61 meter approval DVGW ACS Without CWA CWC CWD CWF CWY Power supply frequency (sensor FEV18 only) 50 Hz 60 Hz F5 F6 Number of testpoints 1 Point 3 Points **Add codes for options. 42 DS/WM–EN Rev. U 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27 X XXX X X X X XX X X X X X X X X X X X X FEV11 T1 T3 Options Product coding field number 1 … 5 Flowmeter system, optimized full bore, integral mount WaterMaster Electromagnetic flowmeter Electromagnetic flowmeter WaterMaster FEF12 and FEF18 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27 X XXX X X X X XX X X X X X X X X X X X X FEF12 Options Product coding field number 1 … 5 Flowmeter system, full bore, remote mount Full bore sensor only, for use with WaterMaster transmitter / remote FEF18 Design Non-hazardous areas Hazardous areas (DN700 [27 in. NB]) 1 5 Bore diameter DN250 (10 in.) DN300 (12 in.) DN350 (14 in.) DN375 (15 in.) DN400 (16 in.) DN450 (18 in.) DN500 (20 in.) DN600 (24 in.) Others 250 300 350 375 400 450 500 600 999 Liner material Elastomer – DN250 to 600 (10 to 24 in. NB) Hard rubber – DN250 to 600 (10 to 24 in. NB) Other K H Z Electrode design Standard Others 1 9 Measuring electrodes material Stainless steel 316 Hastelloy® C-22 Super-austenitic steel (DN250 to 600 [10 to 24 in. NB]) Others S C U Z Grounding accessories Standard One potential equalizing ring (stainless steel) Two potential equalizing rings (stainless steel) Others 1 3 4 9 Process connection type (refer to pages 35 to 33) Flanges ASME B16.5 class 150 Flanges ASME B16.5 class 300 Flanges AWWA C207 class B Flanges AWWA C207 class D Flanges AS 4087 PN21 Flanges AS 4087 PN16 Flanges AS 4087 PN14 Flanges AS 2129 Table F Flanges AS 2129 Table E Flanges AS 2129 Table D Flanges AS 2129 Table C Flanges AS 2129 Table H Flanges AS 4087 PN35 Flanges JIS G5527 7.5K Flanges JIS B2220 10K Flanges JIS B2220 5K Flanges ISO / EN PN6 Flanges ISO / EN PN10 Flanges ISO / EN PN16 Flanges ISO / EN PN25 Flanges ISO / EN PN40 Others Note. DN80 to 200 (3 to 10 in. NB) available only with PN16 A1 A3 C1 C2 E0 E1 E2 E3 E4 E5 E6 E7 E8 J0 J1 J2 S0 S1 S2 S3 S4 Z9 Process connection material Carbon steel flanges Others B Z Usage certifications Standard 1 Calibration type Class 2 calibration – standard accuracy 0.4 % Class 1 calibration – high accuracy 0.2 % Extended range, class 1 calibration – high accuracy 0.2 % Extended range, class 2 calibration – standard accuracy 0.4 % A B N P Continued on next page … DS/WM–EN Rev. U 43 WaterMaster Electromagnetic flowmeter 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27 X XXX X X X X XX X X X X X X X X X X X X FEF12 Full bore sensor only, for use with WaterMaster transmitter / remote FEF18 Temperature range installation / ambient temperature range Standard design / –20 … 60 °C (–4 … 140 °F) 1 Nameplate Adhesive A Signal cable length and type* Without signal cable 5 m (15 ft.) cable 10 m (30 ft.) cable 20 m (60 ft.) cable 30 m (100 ft.) cable 50 m (165 ft.) cable 80 m (260 ft.) cable 100 m (325 ft.) cable 150 m (490 ft.) cable Special Length > 150 m (> 490 ft.) (and / or armored cable) 0 1 2 3 4 5 6 7 8 9 Explosion protection certification General purpose (non-Ex design) A Protection class transmitter / protection class sensor IP67 (NEMA 4X) / IP68 (NEMA 6P) – cable not fitted and not potted IP67 (NEMA 4X) / IP68 (NEMA 6P) – cable fitted and potted 2 3 Cable conduits** M20 x 1.5 (plastic) NPT 1/2 in. (blanked when cable not fitted) M20 SWA (armored) M20 SWA sensor, M20 x 1.5 (plastic) power / output Without A B D F Y Power supply Without 100... 230 V AC (50 Hz) 24 V AC or 24 V DC (50 Hz) 100... 230 V AC (60 Hz) 24 V AC or 24 V DC (60 Hz) 0 1 2 3 4 Input and output signal type HART + 20 mA + pulse + contact output PROFIBUS DP RS485 physical layer + pulse + contact output (general-purpose design only) MODBUS RTU RS485 physical layer + pulse + contact output (general-purpose design only) Without A G M Y Configuration type / diagnostics type Without Factory defaults / standard diagnostics 0 1 Options*** Accessories Configuration lead AC Documentation language German Italian Spanish French English M1 M2 M3 M4 M5 (default) Chinese Swedish Finnish Portuguese Danish Norwegian M6 M7 M8 MA MF MN Verification type Without fingerprint VeriMaster V0 V3 Potable water approvals WRAS cold water approval NSF 61 meter approval DVGW ACS WRAS 60 °C (140 °F) water approval Without CWA CWC CWD CWF CWK CWY Power supply frequency (sensor FEF 18 only) 50 Hz 60 Hz F5 F6 Number of testpoints 1 Point 3 Points T1 T3 *Size is dependent on flange specification **The type of signal cable supplied (standard or armored) depends on the type of cable conduit (variant digit number 24) ordered – for FM or FMC Approved versions, NPT only permitted. ***Add codes for options. 44 DS/WM–EN Rev. U Options Product coding field number 1 … 5 Flowmeter system, full bore, remote mount WaterMaster Electromagnetic flowmeter Electromagnetic flowmeter WaterMaster – FEW31, FEW32 and FEW38 FEW31 Flowmeter system – full bore, remote mount FEW32 Full bore sensor only – for use with WaterMaster transmitter / remote FEW38 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27 X XXX X X X X XX X X X X X X X X X X X X Options Product coding field number 1 … 5 Flowmeter system – full bore, integral mount Design Non-hazardous areas Hazardous areas 1 5 Bore diameter DN10 (3/8 in.) DN15 (1/2 in.) DN20 (3/4 in.) DN25 (1 in.) DN32 (11/4 in.) DN40 (11/2 in.) DN50 (2 in.) DN65 (21/2 in.) DN80 (3 in.) DN100 (4 in.) DN125 (5 in.) DN150 (6 in.) DN200 (8 in.) DN250 (10 in.) DN300 (12 in.) DN350 (14 in.) DN400 (16 in.) DN450 (18 in.) DN500 (20 in.) DN600 (24 in.) DN700 (28 in.) DN750 (29 in.) DN760 (30 in.) DN800 (32 in.) DN900 (36 in.) DN1000 (40 in.) DN1050 (42 in.) DN1100 (44 in.) DN1200 (48 in.) DN1350 (54 in.) DN1400 (56 in.) DN1500 (60 in.) DN1600 (64 in.) DN1650 (66 in.) DN1800 (72 in.) DN1950 (78 in.) DN2000 (80 in.) DN2100 (84 in.) DN2200 (88 in.) DN2400 (96 in.) Others 010 015 020 025 032 040 050 065 080 100 125 150 200 250 300 350 400 450 500 600 700 750 760 800 900 001 051 101 201 351 401 501 601 651 801 951 002 102 202 402 999 Liner material PTFE – DN10 to 600 (3/8 to 24 in. NB) Hard rubber – DN40 to 2400 (11/2 to 96 in. NB) Elastomer – DN40 to 2400 (11/2 to 96 in. NB) A H K Electrode design Standard Other 1 9 Measuring electrodes material Hastelloy® C-4 (2.4610) Stainless steel 316Ti/316L Hastelloy C-22 D S C Grounding accessories Not required Standard One potential equalizing ring (stainless steel) Two potential equalizing rings (stainless steel) 0 1 3 4 Continued on next page… DS/WM–EN Rev. U 45 WaterMaster Electromagnetic flowmeter 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27 X XXX X X X X XX X X X X X X X X X X X X FEW31 Flowmeter system – full bore, remote mount FEW32 Full bore sensor only – for use with WaterMaster transmitter / remote FEW38 Process connection type (refer to pages 21 to 26) Flanges ASME B16.47 series B / B16.5 Class 150 Flanges ASME B16.47 series B / B16.5 Class 300 Flanges ASME B16.47 series A Class 150 Flanges ASME B16.47 series A Class 300 Flanges AWWA C207 Class B Flanges AWWA C207 Class D Flanges AWWA C207 Class E Flanges AWWA C207 Class F Flanges JIS 10K Flanges JIS 5K Flanges AS 4087 PN 16 Flanges AS 2129 Table E Flanges AS 2129 Table D Flanges AS 4087 PN 35 ISO 7005, DIN, EN 1092-1 PN6 ISO 7005, DIN, EN 1092-1 PN10 ISO 7005, DIN, EN 1092-1 PN16 ISO 7005, DIN, EN 1092-1 PN25 ISO 7005, DIN, EN 1092-1 PN40 A1 A3 B1 B3 C1 C2 C3 C4 J1 J2 E1 E4 E5 E8 S0 S1 S2 S3 S4 Process connection material Carbon steel flanges Stainless steel flange B D Usage certifications Standard (without PED) 1 Calibration type Class 2 calibration – standard accuracy 0.4 % Class 1 calibration – high accuracy 0.2 % A B Temperature range installation / ambient temperature range Standard design/ –20 … 60 °C (–4 … 140 °F) 1 Nameplate Adhesive A Signal cable length and type Without signal cable 5 m (15 ft.) cable 10 m (30 ft.) cable 20 m (60 ft.) cable 30 m (100 ft.) cable 50 m (165 ft.) cable 80 m (260 ft.) cable 100 m (325 ft.) cable 150 m (490 ft.) cable Special length or cable type 0 1 2 3 4 5 6 7 8 9 Explosion protection certification* General purpose (non-Ex design) FM Class 1 Div. 2 usFMc Class 1 Div. 2 ATEX / IECEx Zone 2, 21 & 22 A G P M Continued on next page… 46 DS/WM–EN Rev. U Options Product coding field number 1 … 5 Flowmeter system – full bore, integral mount WaterMaster Electromagnetic flowmeter 6 7…9 10 11 12 13 14, 15 16 17 18 19 20 21 22 23 24 25 26 27 X XXX X X X X XX X X X X X X X X X X X X FEW31 Flowmeter system – full bore, remote mount FEW32 Full bore sensor only – for use with WaterMaster transmitter / remote FEW38 Options Product coding field number 1 … 5 Flowmeter system – full bore, integral mount Protection class transmitter / protection class sensor IP67 (NEMA 4X) / IP67 (NEMA 4X) – cable not fitted and not potted to sensor IP 67 (NEMA 4x) / IP68 (NEMA 6P) – cable not fitted and not potted to sensor IP 67 (NEMA 4x) / IP68 (NEMA 6P) – cable fitted and potted to sensor 1 2 3 Cable conduits ** M20 x 1.5 (plastic) NPT 1/2 in. (blanked when cable not fitted) M20 SWA (armored) M20 SWA sensor, M20 x 1.5 (plastic) power / output Without A B D F Y Power supply Without 108.. 230 V AC, 50 Hz 24 V AC or 24 V DC, 50 Hz 100 ... 230 V AC, 60 Hz 24 V AC or 24 V DC, 60 Hz 0 1 2 3 4 Input and output signal type HART + 20 mA + pulse + contact output PROFIBUS DP RS485 physical layer + pulse + contact output (general-purpose design only) MODBUS RTU RS485 physical layer + pulse + contact output (general-purpose design only) Without A G M Y Configuration type / diagnostics type Not required Factory default / Standard 0 1 Options*** Accessories Configuration lead AC Documentation language German Italian Spanish French English M1 M2 M3 M4 M5 (default) Chinese Swedish Finnish Portuguese Danish Norwegian M6 M7 M8 MA MF MN Lay length ISO length – DN10 to 600 (3/8 to 24 in.) and 1.25D DN1800 to 2400 (72 to 96 in.) JB 1.3D DN700 to 2400 (28 to 96 in.) – see dimensional pages 25, 26, 27 JK 1.0D DN700 to 1600 (28 to 64 in.) – see dimensional pages 25, 26, 27 JH Verification type Without fingerprint VeriMaster V0 V3 Potable water approval WRAS cold water approval DVGW WRAS 60 °C (140 °F) water approval NSF material approval Without CWA CWD CWK CWM CWY Power supply frequency (sensor FEW38 only) 50 Hz 60 Hz F5 F6 * FM approval in process. FEF product still available with full FM approval ** The type of signal cable supplied (standard or armored) depends on the type of cable conduit (variant digit number 24) ordered. For FM or FMC Approved versions, NPT only permitted. *** Add codes for options. DS/WM–EN Rev. U 47 WaterMaster Electromagnetic flowmeter WaterMaster FER reduced-bore sensor flowmeter series 1…6 7…9 10 11 12 13 14,15 16 17 18 19 20 21 22 23 24 25 26 27 XXX X X X X XX X X X X X X X X X X X X FER121 WaterMaster system. Reduced-bore sensor with integral transmitter FER111 WaterMaster reduced-bore sensor only, remote mount, without transmitter FER181 Bore diameter DN 40 (11/2 in.) DN 50 (2 in.) DN 65 (21/2 in.) DN 80 (3 in.) DN 100 (4 in.) DN 125 (5 in.) DN 150 (6 in.) DN 200 (8 in.) DN 250 (10 in.) DN 300 (12 in.) DN 350 (14 in.) DN 375 (15 in.) DN 400 (16 in.) DN 450 (18 in.) DN 500 (20 in.) DN 600 (24 in.) 040 050 065 080 100 125 150 200 250 300 350 375 400 450 500 600 Liner material Elastomer – DN40 to 600 (11/2 to 24 in. NB) K Electrode design Standard 1 Measuring electrodes material Stainless steel 316 Super austenitic steel (1.4529) S U Grounding accessories 1 x Stainless steel equalizing ring 2 x Stainless steel equalizing rings 3 4 Process connection type (refer to pages 30 and 30) Flanges ANSI / ASME B16.5 / 16.47 series B Class 150 Flanges AWWA C207 Class E Flanges JIS 7.5K Flanges JIS 10K Flanges AS 4087 PN 21 Flanges AS 4087 PN 16 Flanges AS 4087 PN 14 Flanges AS 2129 Table F Flanges AS 2129 Table E Flanges AS 2129 Table D Flanges AS 2129 Table C ISO 7005 PN 10 EN 1092-1 ISO 7005 PN 16 EN 1092-1 ISO 7005 PN 40 EN 1092-1 (40 / 50 / 80 / 100 / 150 … 300) (40 / 50 / 80) (100 / 150 … 300) (40 / 50 / 80 / 100 / 150 … 300) (50 / 80 / 100 / 150 … 600) (50 / 80 / 100 / 150 … 350 / 450 … 600) (40 / 50 / 80 / 100 / 150 … 600) (40 / 50 / 80 / 100 / 150 … 600) (40 / 50 / 80 / 100 / 125 / 150 … 600) (40 / 50 / 80 / 100 / 150 … 300) (40 / 50 / 80 / 100 / 150 … 300) (40 … 600) (40 … 600) (40) A1 C3 J0 J1 E0 E1 E2 E3 E4 E5 E6 S1 S2 S4 Process connection material Carbon steel B Usage certifications Standard 1 Continued on next page… 48 DS/WM–EN Rev. U Options Product coding field number WaterMaster system. Reduced-bore sensor with remote mounted transmitter WaterMaster Electromagnetic flowmeter 1…6 7…9 10 11 12 13 14,15 16 17 18 19 20 21 22 23 24 25 26 27 XXX X X X X XX X X X X X X X X X X X X FER121 WaterMaster system. Reduced-bore sensor with integral transmitter FER111 WaterMaster reduced-bore sensor only, remote mount, without transmitter FER181 Options Product coding field number WaterMaster system. Reduced-bore sensor with remote mounted transmitter See previous page Calibration type Class 2 calibration – standard accuracy 0.4 % Class 1 calibration – high accuracy 0.2 Extended range, class 1 calibration – high accuracy 0.2 % Extended range, class 2 calibration – standard accuracy 0.4 % A B N P Installation temperature range / ambient temperature range Standard design –20 … 60 °C (–4 … 140 °F) 1 Name plate Adhesive label A Signal cable length and type Without signal cable 5 m (16.4 ft) 10 m (32.8 ft) 20 m (65.6 ft) 30 m (98.4 ft) 50 m (164.0 ft) 80 m (262.5 ft) 100 m (325 ft) 150 m (490 ft) Others 0 1 2 3 4 5 6 7 8 9 Explosion protection certification General purpose (non-Ex design) A Protection class transmitter / protection class sensor IP67 (NEMA 4X) / IP68 (NEMA 6P) – cable not fitted and not potted IP67 (NEMA 4X) / IP68 (NEMA 6P) – cable fitted and potted 2 3 Cable conduits* M20 x 1.5 NPT 1/2 in (blanked when cable not fitted) M20 SWA armored (FEV121 and FEV181 only) M20 SWA sensor, output and power connector (FEV121 and FEV181 only) A B D F Power supply Without (FEV18 only) 100... 230 V AC, 50 Hz 24 V AC or 24 V DC, 50 Hz 100... 230 V AC, 60 Hz 24 V AC or 24 V DC, 60 Hz 0 1 2 3 4 Input and output signal type HART + 20 mA + pulse + contact output PROFIBUS DP RS485 physical layer + pulse + contact output (FEV111 and FEV121 only) MODBUS RTU RS485 physical layer + pulse + contact output (FEV111 and FEV121 only) Without (FEV181 only) A G M Y Configuration type / diagnostics type Without (FEV18 only) Factory defaults / standard diagnostics (FEV11 and FEV12 only) 0 1 Options** Documentation language German Italian Spanish French English M1 M2 M3 M4 M5 (default) Chinese Portuguese Russian Danish M6 MA MB MF Verification type Without fingerprint VeriMaster V0 V3 Potable water approval WRAS cold water approval DVGW ACS CWA CWD CWF Power supply frequency (sensor FER18 only) 50 Hz 60 Hz F5 F6 * The type of signal cable supplied (standard or armored) depends on the type of cable conduit (variant digit number 24) ordered. For FM or FMC Approved versions, NPT only permitted. **Add codes for options. DS/WM–EN Rev. U 49 WaterMaster Electromagnetic flowmeter Electromagnetic flowmeter transmitter for WaterMaster FET10 and FET12 FET10 Remote transmitter FET12 6 7 8 9 10 11 12 13 14 15 X X X X X X X X X Design Non-hazardous area Hazardous area 1 5 Temperature range installation / ambient temperature range Standard design / –20 … 60 °C (–4 … 140 °F) 1 Nameplate Adhesive A Signal cable length Without signal cable 0 Explosion protection Without (transmitter only) FM Class 1 Div. 2 usFMc Class 1 Div. 2 ATEX / IECEx Zone 2, 21 & 22 Y G P M Protection class transmitter / protection class sensor IP67 (NEMA 4X) / IP67 (NEMA 4X) 1 Cable conduits M20 x 1.5 (plastic) NPT 1/2 in. (blanked when cable not fitted) M20 SWA (armored) M20 SWA sensor, M20 x 1.5 (plastic) power / output Without A B D F Y Power supply 100... 230 V AC 24 V AC or 24 V DC 1 2 Input and output HART + 20 mA + pulse + contact output PROFIBUS DP RS485 physical layer + pulse + contact output (general-purpose design only) MODBUS RTU RS485 physical layer + pulse + contact output (general-purpose design only) A G M Configuration type / diagnostics type Factory defaults / standard diagnostics 1 Options** Accessories Configuration lead AC Documentation German Italian Spanish French English M1 M2 M3 M4 M5 (default) Chinese Swedish Finnish Portuguese Danish Norwegian M6 M7 M8 MA MF MN Other usage Measuring Instruments Directive (MID) CM1 *The transmitter converter module Input and Output Signal Type must match the transmitter backplane output configuration (HART or PROFIBUS) – see OI/FET100-EN. **Add codes for options. 50 DS/WM–EN Rev. U Options Product coding field number 1 … 5 Transmitter module WaterMaster Electromagnetic flowmeter Common accessories Acknowledgements Accessory Item Number WaterMaster AC Fuse F1 Type T 250 mA A/S TR5 B20411 WaterMaster DC Fuse F2 Type T 2 A A/S TR5 B20412 WaterMaster Infra Red Comms Pack MJBX9932 WaterMaster Backplane PCB Board (STD) WATX2505 WaterMaster Sensor PCB Board WATX2506 WaterMaster Comms Cable WEBC2500 Signal cable for remote WaterMaster transmitter 5 m (15 ft.) 10 m (30 ft.) 20 m (60 ft.) 30 m (100 ft.) 50 m (165 ft.) 80 m (260 ft.) 100 m (325 ft.) 150 m (490 ft.) 500 m (1650 ft.) STT4500/05 STT4500/10 STT4500/20 STT4500/30 STT4500/50 STT4500/80 STT4500/100 STT4500/150 STT4500/500 Armored signal cable for remote WaterMaster transmitter 5 m (15 ft.) 10 m (30 ft.) 20 m (60 ft.) 30 m (100 ft.) 50 m (165 ft.) 80 m (260 ft.) 100 m (325 ft.) 150 m (490 ft.) 500 m (1650 ft.) STT4501/05 STT4501/10 STT4501/20 STT4501/30 STT4501/50 STT4501/80 STT4501/100 STT4501/150 STT4501/500 Microsoft is a registered trademark of Microsoft Corporation in the United States and/or other countries Modbus is a registered trademark of the Modbus-IDA organization HART is a registered trademark of the HART Communication Foundation DS/WM–EN Rev. U 51 ABB Limited Process Automation Oldends Lane Stonehouse Gloucestershire GL10 3TA UK Tel: +44 1453 826 661 Fax: +44 1453 829 671 ABB Inc. Process Automation 125 E. County Line Road Warminster PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 ABB Engineering (Shanghai) Ltd. Process Automation No. 5, Lane 369, Chuangye Road 201319, Shanghai, P.R. China Phone: +86 (0) 21 6105 6666 Fax: +86 (0) 21 6105 6992 Mail:china.instrumentation@cn.abb.com Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts – is forbidden without prior written consent of ABB. Copyright© 2013 ABB All rights reserved 3KXF211101R1001 Sales Service www.abb.com Software DS/WM–EN Rev. U 10.2013 Contact us
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2013:10:14 10:02:49Z Creator : FrameMaker 10.0.2 Modify Date : 2014:06:09 19:05:12+08:00 Language : en XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 9.3.3 (Windows) Creator Tool : FrameMaker 10.0.2 Metadata Date : 2014:06:09 19:05:12+08:00 Format : application/pdf Title : untitled Document ID : uuid:3d2a4693-8cac-4052-8472-d9e6b9e39b41 Instance ID : uuid:b0b90d17-3c62-4aa9-b1f3-5b0016e878f8 Page Mode : UseOutlines Page Count : 52EXIF Metadata provided by EXIF.tools