ALTIVAR 28 Quick Reference Guide Access to Menus Keypad Operation & Reference 1st power-up after factory configuration ▲ Enters a menu or a parameter, or saves the displayed parameter or value ESC ENT rdY ENT Exits a menu or parameter, or aborts the displayed value to return to the previous value in the memory Goes to the next menu or parameter, or decreases the displayed value SEt Settings LFr rPI rOt ACC dEC AC2 dE2 LSP HSP ItH UFr SLP FLG IdC tdC JPF JOG rPG rIG rbS PIC SP2 SP3 SP4 SP5 SP6 SP7 Ftd Ctd ttd tLS Menu 2 – Drive Menu (DrC) Parameter Nominal Motor Voltage Nominal Motor Frequency Auto-tuning Maximum Output Frequency Type of Volts/Hz Ratio Automatic Ramp Modification for Decel Alternate Accel/Decel Ramp Frequency Carrier Switching Frequency Random Carrier Frequency Modulation Automatic Restart Enable Output Phase Failure Fault Enable Line Supply Phase Failure Fault Controlled Stop on Loss of Line Supply Enable Smooth Restart after Fault Lower Tripping Threshold of Undervoltage Scale Factor of Output Frequency for Speed Return to Factory Settings Code UnS FrS tUn tFr Ft brA Frt SFr nrd Atr OPL IPL StP FLr drn SdS FCS Menu 3 – I/O Menu (I-O) Parameter Control Strategy Configuration (2-wire/3-wire) 2-Wire Control 3-Wire Control Presence of Local Control Option Enable for Start/Stop using Remote Display Logic Input 2 Assignment Logic Input 3 Assignment Logic Input 4 Assignment Not Assigned Reverse Rotation Ramp Switching Code tCC 2C 3C OPt LCC LI2 LI3 LI4 no rrS rP2 Factory Setting 0.0 For 3 sec 3 sec 5 sec 5 sec 0 Hz (bFr) (In) 20 0.0–5.0 Hz 33 0.7In 0.5 sec 0 Hz 10 Hz 1 1 /s 1 no 10 Hz 15 Hz 20 Hz 25 Hz 30 Hz 35 Hz (bFr) 1.5In 100% 0 Factory Setting 230/460V 50/60 Hz no 60/72 Hz n YES 0 Hz 4.0 YES no YES YES no no no 30 no Factory Setting 2C no rrS PS2 PS4 drC ▲ I-O- I/O ▲ SUP- ESC Display Access to Parameters Parameter Menu SEt- ENT ESC Value or assignment -YYY ENT ▲ ESC -UUU 100 ▲ 1 flash (save) ESC ENT 101 101 Next parameter Menu 3 – I/O Menu (I-O) continued Parameter Jog Operation 2 Preset Speeds 4 Preset Speeds 8 Preset Speeds Freewheel Stop DC Injection Braking Fast Stop Forced Local Mode Fault Reset Analog Speed Reference Switching Analog Input Assignment of 2nd Input Not Assigned Summing with All PI Regulator Feedback, setpoint = parameter rP1 PI Regulator Feedback, setpoint = All Minimum Value on Analog Current Input Maximum Value on Analog Current Input Assignment of Analog Output Not Assigned Motor Current Motor Frequency Motor Torque Drive Power Supplied Assignment of Offset for Analog Output Assignment of R2 Relay Not Assigned Frequency Threshold Reached Current Threshold Reached Speed Reference Reached Motor Thermal Threshold Reached Drive Address via Serial Link Serial Link Transmission Speed Code JOG PS2 PS4 PS8 nSt dCI FSt FLO rSt rFC AIC no SAI PII PIA CrL CrH AO no Ocr rFr OLO OPr AOt r2 no FtA CtA SrA tSA Add bdr Menu 4 – Display Menu (SUP) Parameter Control Strategy Configuration (2-wire/3-wire) Enable for Start/Stop using Remote Display Display Calculated Value of Speed or Production Rate (rFr X SdS) Display Motor Current Display Motor Power Display Line Voltage Display Motor Thermal State Display Drive Controller Thermal State Display Last Fault Display Drive Controller Software Version Access Code Protection Display of Controller Status The parameters in colored boxes appear if the corresponding functions have been configured in the dcr or I/O menus. Electrical equipment should be serviced only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. This document is not intended as an instruction manual for untrained persons. If it is not possible to access the “SEt-”, “drC-” or “I-O-” menus, the drive controller is protected by an access code. A remote display module option or PC software is necessary to access these menus, together with knowledge of the code. Drive ▲ Speed Reference via the Display Module PI Reference Direction of Operation Acceleration Time Deceleration Time Acceleration Ramp #2 Deceleration Ramp #2 Low Speed High Speed Motor Full Load Current (protection) Optimize Low Speed Torque (voltage boost) Slip Compensation Frequency Loop Gain DC Injection Braking Current DC Injection Braking Time at Standstill Skip Frequency Jog Frequency PI Regulator Proportional Gain PI Regulator Integral Gain PI Feedback Multiplication Coefficient PI Regulator Reverse Coefficient Preset Speed 2nd Preset Speed 3rd Preset Speed 4th Preset Speed 5th Preset Speed 6th Preset Speed 7th Frequency Threshold where R2 Closes Current Threshold where R2 Closes Motor Thermal where R2 Closes Low Speed Operation Time Code Wait 3 seconds ▲ ▲ Parameter Display of drive controller status ---- ▲ Menu 1 – Adjustment Menu (SEt) Subsequent power-ups ENT bFR configuration (1) ENT ▲ 4 seven-segment displays rdY ▲ z Returns to the previous menu or parameter, or increases the displayed value Base frequency: 50 Hz (factory setting) or 60 Hz -bFr Altivar28 Red LED: powered up (DC bus voltage) ▲ Using the Keypad Display Document Number 8806HO0102 Code FrH rFr SPd LCr OPr ULn tHr tHd LFt CPU COd –– Factory Setting SAI 4 mA 20 mA rFr 0 SrA 1 19.2 Factory Setting Hz Hz — A % V % % — — ESC
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 1 Create Date : 2001:07:19 15:06:52 Producer : Acrobat Distiller 3.01 for Power Macintosh Author : Dotty Creator : QuarkXPress¨: LaserWriter 8 8.7 Title : ATV 28 Ref GuideEXIF Metadata provided by EXIF.tools