Acer AN1600 F1 Specifications (Long) Long Spec V1 2 16 11

User Manual: AN1600

Open the PDF directly: View PDF PDF.
Page Count: 18

DownloadAcer AN1600 F1 Specifications (Long) Long Spec V1 2-16-11
Open PDF In BrowserView PDF
Acer AN1600 F1 Network Storage System Specifications

AN1600 F1 Product Overview
The Acer AN1600 F1 storage system is a cost-effective storage solution, powered by Microsoft Windows
Storage Server offering an easy way for storage centralization, file sharing, data protection, and remote
access.

Product Front view

Product inside view
1.
2.
3.
4.
5.
6.
7.

12 x ECC DDR3 1066/1333 MHz registered memory slots
2 x Intel® Xeon® 5600 series processors supporting up to 6-cores per processor
2 x 720 W 80 PLUS® gold-level efficient hot-swap power supplies (1+1 redundant)
Hot-plug redundant system cooling fans
Power button, System ID button, LED indicators (Power, HDD activity, LAN 1-2 status, system
ID/status/fault)
Support for up to twelve 3.5” hot-plug SATA or SAS hard disk drives
7 x PCI Express® slots with risers

1

Acer AN1600 F1 Network Storage System Specifications
Product Rear View

1.
2.
3.
4.
5.
6.
7.
8.

PS2 keyboard connector
PS2 Mouse connector
2 x USB 2.0 connectors
Management IPMI LAN port
COM (Serial) connector
Video port
2 x Gigabit LAN connector
ID LED

What's New
 Windows Storage Server 2008 R2










Friendly User Interface Customization

Stand-alone NAS OOBE
Single Instance Storage

Performance improvement

SCOM management pack support
iSCSI software version 3.3

Performance improvement

SCOM management pack support
Bitlocker
Branch-Cache-Hosted Cache support
Additional language support

 16 port RAID card support

Pre-configured Models
1
2
3
4

Processor
2 x E5620
2 x E5620
2 x E5620
2 x E5620

Memory
8 GB
8 GB
12 GB
12 GB

Type
Base SAS
Base SATA
Performance SAS
Performance SATA

HDD
12 x 300 GB SAS
12 x 1 TB SATA
12 x 600 GB SAS
12 x 2 TB SATA

4

RAID HBA
LSI MegaRAID 9260-16i
LSI MegaRAID 9260-16i
LSI MegaRAID 9260-16i
LSI MegaRAID 9260-16i

2

Acer AN1600 F1 Network Storage System Specifications
Features and Benefits
Unified Storage File Server
Efficient Operation

Utilizes industry standard
components

Centralized information management with Microsoft-based
storage operating system to manage, protect, and expand.
Works together with Acer Smart Setup and Acer Smart Manager
for ease of installation and setup. Microsoft Management
Console user interface from Windows storage operating system
enables features such as iSCSI and SIS1 to reduce maintenance
and faster backups.
Leveraging industry standard SAS and SATA technology and
powered by the latest Intel processors to protect your investment
and resources for the years to come.

Expand as your business grows Expand beyond the box to external storage to meet the storage
needs of growing businesses.
Enterprise-class features
Based on an established server design using industry standard
server processors, HDDs, interconnects, DDR3 memory and
hot-plug redundant power supplies. The AN1600 F1 is a costeffective NAS solution that comes complete with enterprise class
features such as file de-duplication, snapshots and distributed
file system replication.

Standard Features
Acer Smart Server Manager v1.1
Easy deployment via the latest version of Acer’s Smart Setup. Smart Setup is available both in
box as a driver packed installation DVD or a downloadable file to be put into a USB 2.0 device,
and eases the deployment of Acer servers for any certified OS. Through its unique interface, users
may select to have all the correct drivers be pre-deployed for the OS of their choosing, as well as
setup hardware RAID devices, BMC settings (where available), and even clone the pre-settings to
a bootable USB device to ease mass server deployments.

Acer Smart Console
Web-based management utility to simplify system management with embedded iBMC, system
monitoring and alerting, event handling, remote power control and KVM-over-IP. Smart Console is
OS independent and offers virtual media through floppy, ODD, and removable disk.

Acer Recovery Utility
 A friendly and intuitive system recovery utility to return the system to its original factory settings.
 Supports over twenty different languages.
 Wizard step-by-step guidance through the complete recovery processes.

Acer Resource Kit
 Comprehensive system information in one single disk including System drivers, LAN, RAID, and iSCSI
Target Client utilities, and User Guide.

1

SIS: Single Instance Storage can recover up to 35% of disk capacity by reducing the number of redundant files.

3

Acer AN1600 F1 Network Storage System Specifications
AN1600 F1 features Windows Storage Server 2008 R2 Operating System
Microsoft® Windows® Storage Server 2008 R2 operating system provides file storage and print server
capabilities for client and server computers in your network environment. Storage appliances running
Windows Storage Server 2008 R2 can be used in failover clusters, providing high availability storage
for application servers and file storage.
Single Instance Storage (SIS) v2

File Server Optimization

Remote Administration in
Heterogeneous Environments

Print Services
Distributed File System (DFS)
Namespace and Replication

SIS reduces the amount of storage used by data by
replacing multiple identical copies with logical links to a
single source copy.
Windows Storage Server 2008 R2 is tuned to provide better
performance in a file server role, realizing as much as an 8%
performance gain in file system operations.
Remote administration of Windows Storage Server 2008 R2
appliances can be done from Internet Explorer using an
ActiveX control, and from non-Microsoft browsers using a
Java control.
Windows Storage Server 2008 R2 offers performance
enhancements for the Print Services role.
Windows Storage Server 2008 R2 can provide DFS support
for file sharing for WANs and satellite offices

Microsoft iSCSI Software Target
Microsoft iSCSI Software Target provides centralized, software-based and hardware-independent
iSCSI disk subsystems in storage area networks (SANs). You can use iSCSI Software Target, which
includes a Microsoft Management Console (MMC) snap-in, to create iSCSI targets and iSCSI virtual
disks. You can then use the Microsoft iSCSI Software Target console to manage all iSCSI targets
and virtual disks created using iSCSI Software Target.
Microsoft iSCSI Software Target 3.2 provides the following features:
Server Manager Integration
Improved CHAP Secret
Storage
ERL0 Compliant

Manage your Microsoft iSCSI Software Target from Server
Manager.
Microsoft iSCSI Software Target 3.2 uses a more secure
and customizable storage method for CHAP secrets.
Connection and session reinstatement is now fully ERL0
compliant.

4

Acer AN1600 F1 Network Storage System Specifications
Microsoft Management Console
Microsoft® Management Console (MMC) is an extensible common presentation service for management
applications. MMC unifies and simplifies day-to-day system management tasks. It hosts tools and
displays them as consoles. These tools, consisting of one or more applications, are built with modules
called snap-ins. The snap-ins also can include additional extension snap-ins. Microsoft Management
Console enables system administrators to create special tools to delegate specific administrative tasks
to users or groups. Microsoft provides standard tools with the operating system that perform everyday
administrative tasks that users need to accomplish.
Task Orientation

Integration

Customization of Consoles

Delegation

Overall Interface Simplification

Extensibility

The tools being defined to work with MMC are task oriented
in nature-they cater to the task being performed rather than
merely displaying the raw objects that can be manipulated.
Also, because administrators can customize their own tools,
using pieces from various vendors, they can create tools that
contain only the UI they need to complete their tasks.
The UI for all the management tasks an administrator must
perform are collected into a single console. As new
applications are added to a computer or network, their
administration is integrated into the existing administration
common console.
Administrators can create custom consoles tailored to their
particular management needs. This is useful in enterprise
environments that divide administrator groups according to
duties. For example, you can create a custom console for
software installation and maintenance, another one for
scripts administrators, another one for security Group Policy,
and so on.
Administrators can easily modify existing tools to create new
tools with reduced functionality and less complex views of
the tool namespace, and then give these tools to others. A
person who receives such a tool is presented with a simpler,
more manageable view of the tasks they are being asked to
perform.
All tools built for MMC, from Microsoft or third-party software
vendors, will have a similar appearance, making it easier for
users to use all tools after learning one. Because you can
mix and match tools from any vendor, you can use the best
tool from each management product category. MMC also
enables a single pane of glass to provide functionality across
the interface in a consistent manner.
Developers can extend the base functionality of MMC snapins by creating extension snap-ins. This allows software
vendors to reuse Microsoft tools without writing a lot of code.
Various mechanisms are available for extending snap-ins,
including extending the namespace, context menus,
toolbars, Property pages, and creating Aero Wizards-style
pages.

5

Acer AN1600 F1 Network Storage System Specifications
Product Specifications
Processors and chipset
 2 x Intel® Xeon® E5620 processors (2.4 GHz, 12 MB L3 cache, 5.86 GT/s, DDR3-1066, 80 W, HT)
 Intel® 5520 Chipset

Memory
 Memory capacity:

Registered DIMM: 2, 4, 8 GB

Up to 32 GB supported by the OS.

Minimum: 6GB Required

Network Controllers
 Integrated Intel® 82576EB dual-port Gigabit Ethernet controllers (2 ports total)

Storage
 Hard disk form factor: 3.5”
 Type: SAS/ SATA with hot plug capability
 HDD Capacity (enterprise level):

3.5” SAS HDD capacity: 300 GB, 450 GB, 600 GB

3.5” SATA HDD capacity: 250 GB, 500 GB, 1TB, 2TB
 3.5” Maximum capacity:

Up to 24 TB SATA HDD (2 TB 3.5" x 12 HDDs)

Up to 7.2 TB SAS (600 GB 3.5” x 12 HDDs)

Storage controllers
 LSI SAS MegaRAID SAS PCIe 2.0 x16 9260-16i with 16-internal ports, 512 MB, supporting RAID
0/1/10/5/50/6/60 (default bundle in system)

Expansion slots






Two full height PCI-E 2.0 x8 slots (with x4 link; left)
One full height PCI-E 2.0 x16 slot (with x8 link; left)
Two low profile PCI-E 2.0 x8 slots (with x4 link; right)
One low profile PCI-E 2.0 x8 slot (right)
One Acer Flex I/O (PCI-E 2.0 x8) slot (left)

Operating System
 Microsoft® Windows® Storage Server 2008 R2, Standard x64 edition

Management





Acer Smart Console
Acer Smart Server Manager
iBMC management controller, supporting base board management and KVM-over-IP
LSI MSM (MegaRAID Storage Manager) on-line utility is the OS level utility for data volume RAID
configuration
 LSI WebConsole utility is a ROM-based utility provided by HBA FW for data volume RAID
configuration
 Windows Disk Management is OS built-in feature on Windows Storage Server 2008 R2
 Microsoft Windows Storage Server Administration Tools

6

Acer AN1600 F1 Network Storage System Specifications
Deployment/serviceability
 BIOS Update Tool
 IPMI Firmware Update Tool

Input/output interface
Front
 One Power/off button
 LED indicators: power, HDD activity, LAN port 1 through 2, and ID
Rear









PS2 keyboard port
PS2 mouse port
Two USB 2.0 ports
Two RJ-45 ports (dual Gigabit NIC) with activity and link indicators
RJ-45 port (dedicated for management NIC) with activity and link indicators
Serial (DB-9) port
SVGA (DB-15) port
ID LED

Chassis / Form factor
 2U rack optimized for up to 12 hot-plug SAS/SATA 3.5” HDDs
Power supply
 2 x 720 W 80 PLUS® Gold-level efficient hot-swap power supplies standard (1+1 redundant)
Regulatory compliant standards
EMC
 FCC (Class A)
 CE (Class A)
 BSMI (Class A)
Safety
 UL/cUL
 CB

7

Acer AN1600 F1 Network Storage System Specifications
Technical Specifications
Dimensions
(with bezel)

438.4 mm (W) x 705 mm (D) x 88.1 mm (H) ( 17.3 x 27.8 x 3.5 inches)

Form factor

2U rack mount (with cable arms included)

Weight
(approximate)

Maximum
(All component slots and sockets
fully populated)
Minimum
(One HDD, power supply, and
processor installed)

38 kg (84 lbs.)

BTU rating

Maximum

2456.64 BTU/hr.

System inlet
temperature

Operating

0° - 35°C (50° - 95°F) at sea level with an altitude
derating of 1°C per 305 m (1.8°F per 1000 ft.)
above sea level to a maximum of 3050 m (10,000
ft.) with no direct sustained sunlight. Maximum rate
of change is 10°C/hr. (18°F/hr.). The upper limit
depends on the type and number of options
installed. System performance may be reduced if
operating with a fan fault or above 30°C (86°F).
-40° - 70°C (-40° - 158°F) maximum rate of change
is 20°C/hr. (36°F/hr.).

Non-operating

27.5 kg (60.6 lbs.)

Relative humidity Operating
(noncondensing)
Non-operating

8 - 90 % relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-condensing
5 - 95 % relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-condensing

Emissions
classification
(EMC)

FCC rating

Class A

Normative standards

EN55022, EN 61000-3-2, EN 61000-3-3, CISPR
22 Class A

Power supply

Rated steady-state power

720 W (at 100 VAC)
720 W (at 200 VAC)
720 W (at 100 VAC)
720 W (at 200 VAC)

Maximum peak power

8

Acer AN1600 F1 Network Storage System Specifications
Expansion slots

The primary I/O bus for the main board is PCIe Gen2. The following table lists the characteristics
of the PCI-E bus segments.
PCI express Bus Segment Characteristics of PCI Express Topology
Expansion Slot #

# of
slots

Type

Bus
Width1

Vol.

Con.
Width

Location Length

PCIe

2

PCIe Gen 2

x4

3.3V

x8

Left

Full height

PCIe

1

PCIe Gen 2

x8

3.3V

x16

Left

Full height

PCIe

2

PCIe Gen 2

x4

3.3V

x8

Right

Low profile

PCIe

1

PCIe Gen 2

x8

3.3V

x8

Right

Low profile

Acer Flex I/O

1

PCIe Gen 2

x8

3.3V

x8

Left

NOTE:
1. "Bus Width" refers to the number of physical electrical lanes running to a PCIe® connector.
2. Default bus assignment (in decimal). Inserting cards with PCI™ bridges may alter the actual bus assignment
number.
3. Slots are enumerated differently based on the operating system. Microsoft® operating systems enumerate Device
ID by bus starting from the lowest bus to the highest.

Embedded dual-port
Gigabit server
adapter (Intel
82576EB) two port
total

Network interface

10Base-T
100Base-TX
1000Base-TX

Compatibility

IEEE 802.3 10Base-T
IEEE 802.3ab 1000Base-T
IEEE 802.3u 100Base-TX
Four lane (x4), 100 MHz PCI Express reference clock
10Base-T (half-duplex)
10 Mb/s
10Base-T (full-duplex)
20 Mb/s
100Base-TX (half-duplex)
100 Mb/s
100Base-TX (full-duplex)
200 Mb/s
1000Base-TX (half- and full-duplex) 2000 Mb/s
RJ-45
CAT 5e wire
Intel I/O Acceleration Technology
Virtual Machine Device Queues (VMDq)
PCI-SIG SR-IOV implementation
NC-SI SMBus, PXE, iSCSI boot

Data transfer method
Network transfer rate

Connector
Cable support
Virtualization
acceleration
Manageability

9

Acer AN1600 F1 Network Storage System Specifications
Storage
Maximum internal
storage

Hard disk drive



Up to 12 hot-pluggable 3.5" SATA/SAS HDD

3.5” Maximum
capacity




Up to 24 TB SATA
Up to 7.2 TB SAS

Drive Support – Optical and Hard Disk Drive

Optical Drive Support

Drive
Optical Drive

Bay Supported

Required Controller

External Only

USB 2.0

Hard Disk Drive Support
Drive
3.5” SATA/SAS hard drive

Quantity
Supported

Bay Supported

Up to 12

0 - 11

Required Controller
16-port SAS RAID card for
up to 12 SAS/SATA HDD’s

10

Acer AN1600 F1 Network Storage System Specifications
RAID Volume and Setup Layout
Default 2 HDDs RAID Volume and system partition

Default 8 HDDs RAID Volume and system partition

Default 12 HDDs RAID Volume and system partition

11

Acer AN1600 F1 Network Storage System Specifications

Memory Support Specification
Registered Type

DDR3 1066/ 1333 MHz
Capacity: 2, 4, 8 GB
Voltage: 1.5 V
Maximum: 32 GB (8 GB x 4 DIMMs) (OS maximum support is 32GB)

Memory protection

ECC, Mirroring, Sparing, Lockstep Mode, x4/x8 SDDC

Memory Population
The systems have twelve DIMM slots. Each CPU controls six slots. The DIMM slots support DDR3-1333
registered ECC memory modules.
 Each CPU has three memory channels (channel 1, 2 and 3)
 Each channel has 2 slots
The socket furthest from the CPU is socket A (P1DIMM1A, P1DIMM2A, P1DIMM3A in blue color), while
the nearest is socket B (P1DIMM1B, P1DIMM2B, P1DIMM3B in black). For all memory modes, socket A
in each channel needs to be populated first. If socket A is empty, socket B cannot be used. It is
recommended that the higher rank and largest capacity DIMM be installed in slot A.
For the system to function properly, DIMM modules must be installed following the slot sequence listed
below. DIMM modules of the same type, size and manufacturer must be installed in the same DIMM
colored slots.
 CPU 1 – populate DIMM slot P1DIMM1A first, followed by slots P1DIMM2A, P1DIMM3A, P1DIMM1B,
P1DIMM2B, P1DIMM3B.
 CPU 2 – populate DIMM slot P2DIMM1A first, followed by slots P2DIMM2A, P2DIMM3A, P2DIMM1B,
P2DIMM2B, P2DIMM3B.
DIMM slot notation illustrated in table below:
CPU1
P1DIMM1B
P1DIMM1A
P1DIMM2B
(Rear CPU) Black
Blue
Black
CPU2
(Front CPU)

P2DIMM1B
Black

P2DIMM1A
Blue

P2DIMM2B
Black

P1DIMM2A
Blue

P1DIMM3B
Black

P1DIMM3A
Blue

P2DIMM2A
Blue

P2DIMM3B
Black

P2DIMM3A
Blue

12

Acer AN1600 F1 Network Storage System Specifications
Independent mode (please refer to the User Guide for more information)
 In this mode all memory is accessible and ECC protected
Single-processor configuration
Total
Memory

P1
1B

P1
1A

2GB

2GB

4GB

2GB

6GB

2GB

P1
2B

P1
2A

2GB

2GB

2GB

2GB

2GB

12GB

2GB

2GB

2GB

2GB

4GB

4GB

8GB

4GB

4GB

12GB

4GB

4GB

16GB

4GB

4GB

4GB

4GB

24GB

4GB

4GB

4GB

4GB

8GB

16GB

8GB

24GB

8GB

32GB

8GB

P1
3A

2GB

8GB

8GB

P1
3B

2GB
2GB

2GB

4GB
4GB

4GB

8GB
8GB

8GB

8GB

8GB

8GB

Dual-processor configuration
CPU1
Total
Memory

P1
1B

P1
1A

P1
2B

CPU2
P1
2A

4GB

2GB

8GB

2GB

2GB

12GB

2GB

2GB

P1
3B

P1
3A

2GB

2GB

2GB

18GB

2GB

2GB

2GB

2GB

2GB

2GB

24GB

2GB

2GB

2GB

2GB

2GB

2GB

8GB

4GB

16GB

4GB

4GB

24GB

4GB

4GB

4GB

P2
2B

2GB
2GB

2GB

4GB

P2
1A

P2
2A

P2
3B

P2
3A

2GB

16GB

32GB

P2
1B

2GB

2GB
2GB

2GB

2GB
2GB

2GB
2GB

2GB

2GB

2GB
2GB

2GB

2GB

2GB
2GB

2GB

4GB

4GB

4GB

4GB
4GB

4GB

4GB
4GB

4GB

4GB
4GB

4GB

4GB

Mirroring mode:
• In mirroring mode, the memory contains a primary image and a copy of the primary image therefore the
effective size of memory is reduced by one half.
• Channel 3 has no function in these modes.
• Follow the population rules described in independent mode.
• Mirroring mode needs the channel 1 & channel 2 DIMMs to be identical. DIMM slot populations within a
channel do not have to be identical but the same DIMM slot location across channel 1 and channel 2
must be the same. DIMM1A and DIMM2A should be the same type, size and manufacturer. DIMM1B
and DIMM2B memory should be the same type, size and manufacturer. DIMM1C and DIMM2C
memory should be the same type, size and manufacturer.
• Same rules apply to CPU2.
• Please refer to the User Guide for complete population rules for both single and dual processor
configurations.
Lockstep mode:
• In Lockstep Channel Mode, each memory access is 128-bit data access that spans Channel 1 and
Channel 2. This is done to support SDDC for DRAM devices with 8-bit wide data ports. The same
address is used on both channels such that an address error on any channel is detectable.

13

Acer AN1600 F1 Network Storage System Specifications
•
•
•
•

•
•

Lockstep Channel mode is the only RAS mode that supports x8 SDDC.
Channel 3 has no function in these modes.
Follow the population rules described in independent mode.
Lockstep mode needs the channel 1 & channel 2 DIMMs to be identical. DIMM slot populations within a
channel do not have to be identical but the same DIMM slot location across channel 1 and channel 2
must be the same. DIMM1A and DIMM2A should be the same type, size and manufacturer. DIMM1B
and DIMM2B memory should be the same type, size and manufacturer. DIMM1C and DIMM2C
memory should be the same type, size and manufacturer.
Same rules apply to CPU2.
Please refer to the User Guide for complete population rules for both single and dual processor
configurations.

Sparing mode:
• In sparing mode, if the system detects degrading memory, the data in the failed channel will be copied to
the spare channel. The failed channel is then isolated and the spare channel becomes active. Any
uncorrectable error detected before the isolation will cause the system to stop normal operation.
• Channel 3 is the spare channel. Therefore, the effective size will be reduced by one-third.
• Follow the population rules described in independent mode.
• Sparing mode needs all three channels to utilize identical DIMMs. 1A, 2A and 3A should be the same
type, size and manufacturer. 1B, 2B and 3B memory should be the same type, size and manufacturer.
1C, 2C and 3C memory should be the same type, size and manufacturer.
• Same rule is applied to CPU2.
• Please refer to the User Guide for complete population rules for both single and dual processor
configurations.

Memory Identification
Generally, there is memory information printed on the label of the DIMM, but different vendors may have
different formats. For example:
4GB 2Rx4 PC3-10600R xx xx xxx
1. Density
 2GB, 4GB, 8GB
 Intel® Xeon® 5600 series processors support DIMMs organized by 1Gb, 2Gb or 4Gb DRAM chips
2. Rank
 1R = Single Rank
 2R = Dual Rank
 4R = Quad Rank
3. Bit Organization
 This platform supports x4 and x8
 Note: It’s not recommend to mix DIMMs with different bit organizations in one system
4. Speed
 PC3 – 6400 => DDR3- 800
 PC3 – 8500 => DDR3- 1066
 PC3 – 10600 => DDR3- 1333

14

Acer AN1600 F1 Network Storage System Specifications
Power Supply Specification
720W Power Supply
Operational Input Voltage
Range (Vrms)

100 to 240 VAC

Frequency Range
(Nominal) (Hz)

50 / 60

Nominal Input Voltage
(Vrms)

100

120

208

200

220

230

240

Max. Rated Output Wattage

720

720

720

720

720

720

720

Nominal Input Current (A
rms)

8.46

6.97

3.80

3.87

3.74

3.5

3.29

Max. Rated Input Wattage
Rating (Watts)

846.0

836.4

790.4

774.0

822.8

805.0

789.6

Max. Rated VA (Volt-Amp)

837.54

828.03

774.59

758.52

806.34

788.9

773.81

Efficiency (%) at Max.
Rated Output Wattage

88.12

89.49

90.95

90.74

91.51

91.92

92.27

Power Factor

0.99

0.99

0.98

0.98

0.98

0.98

0.98

Leakage Current (mA)

0.17

0.19

0.29

0.31

0.35

0.37

0.41

Max. Inrush Current (A
peak)

17.24

19.41

18.52

16.88

16.48

20.47

22.54

Max. Inrush Current
Duration (mS)

4.62

4.58

4.61

4.62

4.64

4.63

4.64

Max. British Thermal Unit
Rating (BTU/hr.)

2456.64

2456.64 2456.64 2456.64 2456.64 2456.64

2456.64

15

Acer AN1600 F1 Network Storage System Specifications
Hardware Key Options
HDD
Memory
SAS RAID

Fibre Channel HBA










Rackmount kits



SAS 3.5”: 300 GB, 450 GB, 600 GB
SATA 3.5”: 250 GB, 500 GB, 1TB, 2 TB
DDR3 1333 MHz Registered ECC 2/ 4/ 8 GB
MegaRAID SAS 9240-4i, 4 internal ports, PCIe x8, supporting RAID 0/1/10/5
MegaRAID SAS 9260-16i, 16 internal ports, 512 MB PCIe x8, supporting
RAID 0/1/10/5/50/6/60
LSI® BBU07/ Battery Backup Unit for MegaRAID SAS 9260-8i and 9260-16i
Qlogic SANblade® QLE2460 single port fibre channel to PCI express host
bus adapter, 1 ch, 8 Gb FC HBA, PCIe x8, single LC port (std & low-profile
bracket)
Qlogic SANblade® QLE2462 dual ports fibre channel to PCI express host
bus adapter, 2ch, 8 Gb FC HBA, PCIe x8, dual LC port (std & low-profile
bracket)
Sliding rails (Cable Management Arm option available)

16

Acer AN1600 F1 Network Storage System Specifications

Service and Support
Acer Servers offer a comprehensive service suite to take care of daily IT needs. Users can select the 3year standard warranty or choose extended warranties and services2.
The standard warranty for the AN1600 F1 includes 3 years Parts coverage with the first year including
Labor and On-Site coverage.
Warranty repairs may be accomplished through the use of Customer Replacement Unit (CRU) parts. CRU
parts include: Hot Plug Hard Drives and Hot Plug Power Supplies. These parts are designed for easy
replacement without tools. Travel and labor charges may apply if customers decline to replace a CRU part.
In a continuing effort to improve the quality of our products, information in this document is subject to change without
notice. Images shown are only representations of some of the configurations available for this model. Availability may
vary depending on region. Microsoft and Windows are registered trademarks of Microsoft Corporation. Intel, the Intel
logo, Pentium, Xeon and Xeon Inside are trademarks of Intel Corporation.
© 2010. All rights reserved.

2

Extension warranty services may vary by country. Please contact your Acer authorized reseller for more information.

17

Acer AN1600 F1 Network Storage System Specifications

Acer Standard Storage Models

Part Number

Acer AN1600 Models
Acer AN1600F1, 2 x Xeon E5620, 4x2GB DDR3 Reg, 12 x 300GB 15K SAS, 16 Port 6G SAS RAID
controller, 2x720W 80+ Gold PSU, 2x GBit LAN onboard, Acer Smart Manager, UPS Power Cable, no
Mouse, no KB, Rail kit (2U) Included

TS.R760R.011

Acer AN1600F1, 2 x Xeon E5620, 4x2GB DDR3 Reg, 12 x 1TB SATA, 16 Port 6G SAS RAID
controller, 2x720W 80+ Gold PSU, 2x GBit LAN onboard, Acer Smart Manager, UPS Power Cable, no
Mouse, no KB, Rail kit (2U) Included

TS.R760R.012

Acer AN1600F1, 2 x Xeon E5620, 6x2GB DDR3 Reg, 12 x 600GB 15K SAS, 16 Port 6G SAS RAID
controller, 2x720W 80+ Gold PSU, 2x GBit LAN onboard, Acer Smart Manager, UPS Power Cable, no
Mouse, no KB, Rail kit (2U) Included

TS.R760R.013

Acer AN1600F1, 2 x Xeon E5620, 6x2GB DDR3 Reg, 12 x 2TB SAS, 16 Port 6G SAS RAID controller,
2x720W 80+ Gold PSU, 2x GBit LAN onboard, Acer Smart Manager, UPS Power Cable, no Mouse, no
KB, Rail kit (2U) Included

TS.R760R.014

Acer Memory
Note: please refer to "Memory Support" Section for details on configuring memory
Acer Registered Memory
Acer 2GB DDR3-1333Registered Memory Kit (1 pc.)
Acer 4GB DDR3-1333Registered Memory Kit (1 pc.)
Acer 8GB DDR3-1333Registered Memory Kit (1 pc.)

TC.33100.029
TC.33100.031
TC.33100.042

Acer Storage
Acer SATA Hot Plug LFF (3.5-inch) Midline (MDL) Drives
Acer 250GB 3Gb/s 7.2K 3.5-inch Enterprise SATA HDD Kit
Acer 500GB 3Gb/s 7.2K 3.5-inch Enterprise SATA HDD Kit
Acer 1TB 3Gb/s 7.2K 3.5-inch Enterprise SATA HDD Kit
Acer 2TB 3Gb/s 7.2K 3.5-inch Enterprise SATA HDD Kit
Acer SAS Hot Plug LFF (3.5-inch) Enterprise Drives
Acer 300GB 6Gb/s 15K 3.5-inch Enterprise SAS HDD Kit
Acer 450GB 6Gb/s 15K 3.5-inch Enterprise SAS HDD Kit
Acer 600GB 6Gb/s 15K 3.5-inch Enterprise SAS HDD Kit

TC.32700.068
TC.32700.066
TC.32700.064
TC.32700.062
TC.32700.079
TC.32700.077
TC.32700.075

Acer SAS Storage Controllers
Acer 4-port 6Gb/s SAS RAID Adapter (w/ mSAS-mSAS cable) Kit
Acer 8-port 6Gb/s SAS RAID Adapter (w/ mSAS-mSAS cable) Kit
Acer 16-port 6Gb/s SAS RAID Adapter (w/ mSAS-mSAS cable) Kit
Acer Battery Backup Kit for Cache module in 8port/16port SAS RAID Card

TC.32300.028
TC.32300.034
TC.32300.042
TC.34800.006

Acer Fibre Channel Storage Controllers
Acer 8Gb/s Single Port Fibre Channel HBA Kit
Acer 8Gb/s Dual Port Fibre Channel HBA Kit
Acer Cable Management Arm (2U/4U) Kit (1000mm Rack required)

TC.32300.024
TC.32300.026
TC.33700.021

18



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 18
Language                        : en-US
Tagged PDF                      : Yes
Title                           : Acer AN1600 F1 Specifications (Long)
Author                          : Steve YM Chen
Subject                         : AR160
Creator                         : Microsoft® Word 2010
Create Date                     : 2011:02:16 11:14:16-06:00
Modify Date                     : 2011:02:16 11:14:16-06:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools

Navigation menu