G1072 Agilent GC LC MS Catalog
User Manual: G1072
Open the PDF directly: View PDF .
Page Count: 462
Download | |
Open PDF In Browser | View PDF |
GC AND GC/MS 250 GC AND GC/MS www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 LC AND LC/MS 710 LC AND LC/MS www.agilent.com/chem/LC www.crawfordscientific.com l 01357 522 961 In this Chapter 252 GC and GC/MS Maintenance Schedule Parts and Supplies 254 280 318 337 GC General Supplies GC Instrument Parts and Supplies GC/MS Parts and Supplies GC Parts and Supplies for Varian Instruments GC and GC/MS Applications 568 617 641 671 686 Environmental Applications Foods, Flavors and Fragrance Applications Industrial Chemical Applications Life Science Applications Petroleum Applications Agilent J&W GC and GC/MS Columns 359 362 364 392 430 442 461 524 531 532 559 Ultra Inert Columns Guard Columns Low-bleed GC/MS Columns Polysiloxane Polymers Columns Polyethylene Glycol (PEG) Columns PLOT Columns Special Application Columns Packed GC Columns Test Standards Fused Silica Tubing GC Column Troubleshooting and Maintenance GC AND GC/MS 251 In this Chapter Parts and Supplies 712 716 739 752 758 762 772 775 787 Bio-inert Supplies General Supplies Pump Supplies Autosampler Supplies Fraction Collector Supplies Valve Supplies TCC Supplies Detector Supplies LC/MS Supplies LC and LC/MS Columns 796 806 818 891 916 945 996 HPLC Column Selection Cartridge Column Systems Columns for Analytical HPLC Columns for Special Applications Preparative HPLC Columns and Flash Chromatography GPC/SEC Columns and Calibrants Biosolutions and Columns for Biologic Characterization LC and LC/MS Troubleshooting 1052 HPLC Troubleshooting 1056 LC/MS Troubleshooting LC and LC/MS Applications 1059 1076 1079 1088 1102 BioPharmaceutical Applications Chemical/Industrial Applications Environmental Applications Food and Consumer Product Applications Pharmaceutical Applications LC AND LC/MS 711 GC/MS Parts and Supplies GC/MS Parts and Supplies Your mass spectrometer is a sensitive, specialized device that delivers a higher level of functionality than other GC detectors. To continue achieving optimal results, it is critical to maintain your system properly by performing the essential tasks within this section. Some of the benefits of maintaining your GC/MSD include: • Less downtime for repairs • Longer lifetime for your MSD system • Reduction in overall operating costs It is advisable to keep a log book of system performance, Autotune, and maintenance operations performed. This makes it easier to identify variations from normal performance and to take corrective action. Maintenance Schedule Task Every week Every 6 months Every year As needed Tune the MSD ] Change injection port liners ] Check the foreline pump oil level ] Gas ballast the foreline pump ] Check the calibration vial ] Replace the foreline pump oil ] Check the diffusion pump fluid ] Replace the diffusion pump fluid ] Replace the dry pump ] diaphragm seals (MVP55) Replace the dry pump tip seals (IDP3) ] Replace the traps and filters ] Clean the ion source ] Change the carrier gas trap(s) ] and purifier Replace worn out parts ] Lubricate seals (where appropriate) ] Replace column ] For in-depth information about maintaining your GC/MS, request "Maintaining Your Agilent GC and GC/MS Systems" from your Agilent Representative (publication number 5990-5451EN). 318 GC AND GC/MS www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 MSD Contamination MSD Contamination Contamination is usually identified by excessive background in the mass spectra, which can come from the GC or MSD. The source of contamination can sometimes be determined by identifying the contaminants. Some contaminants are much more likely to originate in the GC, while others are likely to originate in the MSD. MSD Contamination Identification The following table lists some of the more common contaminants, the ion characteristics of those contaminants, and the likely sources of those contaminants. Tips & Tools A crude sign of a "leak-free" MS system is when the ion ratio of m/z 28 (nitrogen) over m/z 32 (oxygen) is approximately two or greater. Common Contaminants Ions (m/z) 13, 14, 15, 16 18, 28, 32, 44 or 14, 16 Compound Methane H20, N2, O2, CO2, CO2 or N, O 31, 51, 69, 100, 119, 131, 169, 181, 214, 219, 264, 376, 414, 426, 464, 502, 576, 614 31 43, 58 78 91, 92 105, 106 151, 153 69 PFTBA and related ions Methanol Acetone Benzene Toluene or Xylene Xylene Trichloroethane Foreline pump fluid or PFTBA 73, 147, 207, 221, 281, 295, Dimethylpolysiloxane 355, 429 77, 94, 115, 141, 168, 170, Diffusion pump fluid 262, 354, 446 149 Plasticizer (phthalates) Peaks spaced 14 amu apart Hydrocarbons Possible Source CI gas Residual air and water, air leaks, outgassing from Vespel ferrules PFTBA (tuning compound) Cleaning solvent Cleaning solvent Cleaning solvent Cleaning solvent Cleaning solvent Cleaning solvent Foreline pump oil vapor or calibration valve leak Septum bleed or methyl silicone column coating Diffusion pump fluid and related ions Vacuum seals (O-rings) damaged by high temperatures, use of vinyl or plastic gloves Fingerprints, foreline pump oil PARTS AND SUPPLIES 319 MSD Contamination Cleaning and Maintenance Supplies Description One Year Maintenance Kit (for diffusion pump systems) Includes Big Universal Trap for He (1/8 in.), abrasive sheets (5/pk), lint-free cloths (15/pk), cotton swabs (100/pk), SantoVac Ultra, 18.5 mL (2 each), rough pump oil (1 L), filament assembly, octafluoronapthalene (OFN) Nylon gloves, lint-free, large, 1 pair Nylon gloves, lint-free, small, 1 pair Lint-free industrial wipes, 100% cotton, 9 x 9 in., 300/pk Ion source cleaning kit Includes lint-free cloths (15/pk), abrasive sheets (5/pk), cotton swabs (100/pk), lint-free nylon gloves, abrasive Alumina powder Cloths, lint-free, 15/pk Cotton swabs, 100/pk Abrasive sheets, aluminum oxide green lapping paper, 600 mesh, 5/pk Alumina powder, abrasive, 1 kg PFTBA sample, certified, 10 g, 5.32 mL Replacement glass bulb for PFTBA and PFDTD test sample Replacement glass vial for PFTBA and PFDTD test sample Activated alumina, absorbent pellets for Edwards rough pump traps, non-LC/MS, 1 lb can MSD Tool Kit, 5975/5973 Includes source hold tool, lint-free cloth, cotton swabs, lint-free nylon gloves, abrasive sheets, wrenches and driving tools MSD Tool Kit, 5972/5971 Includes small cleaning rod, large cleaning rod, source hold tool, cotton swabs, lint-free nylon gloves, abrasive sheets, wrenches and driving tools Part No. 5183-2096 8650-0030 8650-0029 9310-4828 5181-8863 05980-60051 5080-5400 5061-5896 8660-0791 8500-0656 G3170-80002 05980-20018 8500-1233 G1099-60566 05971-60561 MS Interface Supplies MS interface column nut, 05988-20066 MS interface column nut, female Inlet column nut for long or long two-hole ferrules Universal column nut, 2/pk MS interface column installation tool for 5973 and 5975 Column installation tool for 5975T 05988-20066 05921-21170 5181-8830 G1099-20030 G3880-20030 (Continued) Universal column nut, 5181-8830 Column installation tool, G1099-20030 320 GC AND GC/MS www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 MSD Contamination Cleaning and Maintenance Supplies Description Part No. Tools Screwdriver, 3 in. Pozidriv shaft No. 1 pt, fits no. 2-4 screws Screwdriver, 4 in. Pozidriv shaft No. 2 pt, fits no. 5-10 screws Open end wrench, 1/4 and 5/16 in. Hex nut driver, 5.5 mm Screwdriver, Torx T20 Screwdriver, Torx T15 Screwdriver, Torx T10 8710-0899 8710-0900 8710-0510 8710-1220 8710-1615 8710-1622 5182-3466 Ferrules Vespel/Graphite ferrules, 5181-3323 0.4 mm Vespel/Graphite ferrule for 200/250 µm columns, 10/pk 0.5 mm Vespel/Graphite ferrule for 320 µm columns, 10/pk 250 µm Vespel/Graphite ferrule, 10/pk SilTite metal ferrules for 1/16 in. OD tubing, 10/pk Includes 2 column nuts SilTite metal ferrules, 1/16 in. x 0.4 mm ID, 10/pk Includes 2 column nuts SilTite metal ferrules, 1/16 in. x 0.5 mm ID, 10/pk Includes 2 column nuts Ferrule pre-swaging tool Plug for microfluidic manifold or unions 5062-3508 5062-3506 5181-3323 5184-3571 5184-3569 5184-3570 G2855-60200 G2855-60570 Tips & Tools Even preconditioned ferrules can shrink slightly at very high temperatures. If leak problems persist upon a new column installation, check this fitting first. PARTS AND SUPPLIES 321 Ion Source Ion Source Electron Impact (EI) Ion Source The ion source operates by electron ionization (EI) or chemical ionization (CI). The sample enters the ion source from the GC/MSD interface. Electrons emitted by a filament enter the ionization chamber, guided by a magnetic field. The high-energy electrons interact with the sample molecules, ionizing and fragmenting them. The positive voltage on the repeller pushes the positive ions into the lens stack, where they pass through several electrostatic lenses. These lenses concentrate the ions into a tight beam, which is directed into the mass filter. Electron Impact (EI) Ion Source The recommended cleaning material for the EI ion source is abrasive, aluminum oxide powder. Do not immerse filaments or lens insulators in solvent. If insulators are dirty, clean them with a cotton swab dampened with reagent-grade methanol. If that does not clean the insulators, replace them. 5975/5973 MSD Electron Impact Ion Source Parts (EI) Item Description 1 Ion source body 2 Drawout plate, 3 mm Drawout plate, 6 mm 3 Drawout cylinder 4 Ion focus lens 5 Lens insulator 6 Entrance lens 7 Cap screw, gold plated 8 High temperature filament 9 Transfer line socket 10 Repeller insulator 11 Repeller Part No. G1099-20130 05971-20134 G3163-20530 G1072-20008 05971-20143 G3170-20530 G3170-20126 G1999-20021 G2590-60053 G1099-20136 G1099-20133 G1099-20132 6 5 9 4 3 11 2 10 1 7 8 5975/5973 MSD Electron Impact (EI) ion source assembly 322 GC AND GC/MS www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 Inert Part No. G2589-20043 G2589-20100 G2589-20045 G1072-20008 05971-20143 G3170-20530 G3170-20126 G1999-20021 G2590-60053 G1099-20136 G1099-20133 G2589-20044 Ion Source Tips & Tools It is good practice to replace scratched lenses and other ion source parts regularly. Scratched source parts lead to poor performance. 5972/5971/GCD MSD Ion Source Parts (EI) Description Entrance lens Lens insulator Ion focus lens Drawout cylinder Drawout plate, 3 mm Set screw Repeller assembly Screw for filament on the source Transfer line tip, gold plated Part No. 05971-20126 G3170-20530 05971-20143 G1072-20008 05971-20134 0515-1446 05971-60170 0515-1046 05971-20305 Warnings & Caution Important: Do not abrasively or ultrasonically clean the insulators. Abrasively clean the surfaces that contact the sample or ion beam. Use an abrasive slurry of alumina powder and reagent-grade methanol on a cotton swab. Use enough force to remove all discoloration. Polishing the parts is not necessary; small scratches will not harm performance. Abrasively clean discoloration where electrons from filaments enter the source body. Take care to avoid contaminating cleaned and dried parts. Put on new, clean gloves before handling the parts. Do not put the cleaned parts on a dirty surface. Place them only on clean, lint-free cloths. PARTS AND SUPPLIES 323 Ion Source Chemical Ionization (CI) Ion Source Tips & Tools Visual appearance is not an accurate guide to cleanliness of the CI ion source. The CI ion source can show little or no discoloration, yet still need cleaning. Because the CI ion source operates at much higher pressures than the EI ion source, it will probably require more frequent cleaning than the EI ion source. The source should be cleaned whenever there are performance anomalies that are associated with a dirty ion source. Let analytical performance be your guide. When cleaning the CI ion source, concentrate on the CI repeller, ion source body, and drawout plate. Be sure to clean the 0.5 mm diameter holes in the ion source body and drawout plate. Cleaning the ion source is very similar to cleaning the EI ion source. Use the same EI cleaning procedure with the following exceptions: • The CI ion source may not look dirty, but deposits left by chemical ionization are very difficult to remove. Clean the CI ion source thoroughly. • Use a round wooden toothpick to gently clean out the electron entrance hole in the source body and the ion exit hole in the drawout plate. • Do not use halogenated solvents. Use hexane for the final rinse. 324 GC AND GC/MS www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 Ion Source 5975/5973 MSD Chemical Ionization Ion Source Parts (CI) Item 1 2 3 5 4 6 7 8 9 10 11 Description Source body Drawout plate Drawout cylinder Ion focus lens Lens insulator Entrance lens Repeller insulator Repeller High temperature filament Cap screw, gold plated Interface tip seal/spring Part No. G1999-20430 G1999-20446 G1999-20444 G1999-20443 G3170-20540 G3170-20126 G1999-20433 G1999-20432 G1099-80053 G1099-20021 G1999-60412 6 11 5 4 3 2 9 1 8 7 10 5975/5973 MSD Chemical Ionization (CI) ion source assembly PARTS AND SUPPLIES 325 QuickSwap MS Interface Restrictors QuickSwap MS Interface Restrictors Agilent's QuickSwap Capillary Flow Technology module and pre-swaged fused silica tubing restrictors can increase the productivity of your Agilent 5973N and 5975 Inert MSD Systems, allowing you to change columns without venting the MSD. QuickSwap not included. These restrictors are prefabricated for convenience and ease-of-use. For applications requiring other restrictor sizes, Agilent offers a wide variety of deactivated fused silica tubing, SilTite ferrules and swaging tools. QuickSwap MS Interface Restrictors Description ID (mm) QuickSwap restrictor 0.092 QuickSwap restrictor 0.100 QuickSwap restrictor 0.110 QuickSwap restrictor 0.120 QuickSwap restrictor variety pack, 2 each of the above ID restrictors Unit 4/pk 4/pk 4/pk 4/pk Part No. G3185-60361 G3185-60362 G3185-60363 G3185-60364 G3185-60300 SilTite Metal Ferrules Description For use with 0.25 mm ID capillary columns For use with 0.32 mm ID capillary columns For use with 1/16 in. OD stainless steel tubing Includes 2 column nuts For use with 0.53 mm ID capillary columns 326 GC AND GC/MS www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 Unit 10/pk 10/pk 10/pk Part No. 5188-5361 5188-5362 5184-3571 10/pk 5188-5363 MSD Filaments MSD Filaments Like the filaments in an incandescent light bulb, the ion source filaments will eventually burn out. Certain practices will reduce the chance of early failure. Filament assembly (EI), G3170-60050 • When setting up data acquisition parameters, set the solvent delay so that the analyzer will not turn on while the solvent peak is eluting • When the software prompts 'Override solvent delay at the beginning of a run' always select 'No' • Higher emission current will reduce filament life • If you control your MSD from the Edit Parameters screen, always select 'MS Off' before changing any of the filament parameters MSD Filaments Description Filament assembly (EI) Filament assembly (CI) Micro ion vacuum gauge Triode gauge tube for measuring vacuum Ion gauge controller Ion gauge tube 5975 Series G3170-60050 G1099-80053 G3170-80001 5975T Series 5973 Series G3170-60050 G1099-80053 5972 Series G3170-60050 5971 Series 05971-60140 0960-0897 G3880-80010 G3880-80011 Tips & Tools It is very useful to switch from one filament to the other every three months so that when a filament fails, you know the other will fail soon. This will allow you to change both filaments at the same time. Since the GC/MS system is already vented, it's a good idea to replace other supplies in the flowpath at the same time as the filaments. PARTS AND SUPPLIES 327 MSD Electron Multipliers and Replacement Horn MSD Electron Multipliers and Replacement Horn Electron multiplier replacement horn The lifetime of an electron multiplier is directly related to the current that flows through it and the extent of contamination or condensation that it experiences. Replace the electron multiplier or replacement horn when voltage is over 2500 V. To maximize electron multiplier life: • Maintain the best possible vacuum, especially in the analyzer manifold • Use extreme caution and be conservative with venting, pumpdown, and all vacuum system procedures to keep pump fluid background to a minimum • After venting, allow four hours for pumpdown and thermal equilibration before scanning • Actively look for background contamination and leaks and repair them immediately • Don't tune excessively – PFTBA can result in higher background over an extended period of time • Replace the electron multiplier if vacuum is poor or voltage is over 2500 V MSD Electron Multipliers and Replacement Horn Description Electron multiplier replacement horn Use with electron multipliers with "straight" horns Triple axis detector assembly* Triple axis electron multiplier EM signal wire, low noise detector High energy dynode Electron multiplier 5975 Series 05971-80103 5973 Series 05971-80103 G3170-80100 G3170-80103 G3170-80008 G1099-80001 *Included on 5975 triple axis detector systems Tips & Tools The Agilent multipliers and horns listed are recommended for your MSD. Other manufacturers' products may be incompatible with Agilent instruments and can result in reduced sensitivity, lifetime, and noise problems. 328 GC AND GC/MS 5972/5971 Series 05971-80103 www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 05971-80102 Vacuum Systems and Pumps Vacuum Systems and Pumps Diffusion Pump It is not necessary to change the diffusion pump fluid more than once a year, unless you observe symptoms that suggest a problem with the fluid. The MSD must be vented in order to check the diffusion pump fluid (except for the 5975/5973). Therefore, the best time to check the fluid is when the instrument is already vented for other maintenance. Foreline Pump Foreline Pump The oil in the foreline or rough pump should be replaced on average once every six months, but can vary depending upon applications. If a foreline trap is present, the molecular sieves should also be replaced after an oil change. Avoid contact with the pump oil. The residue from some samples may be toxic. Dispense of used oil properly. Pump Oils Description Foreline pump oil, Inland 45, 1 L High vacuum grease, 25 g Diffusion pump fluid, 18.5 mL IDP Series tip seal kit for 5975T Part No. 6040-0834 6040-0289 6040-0809* IDP3TS *2 required for 5975 and 5973 Series PARTS AND SUPPLIES 329 7000A Triple Quadropole GC/MS Series 7000A Triple Quadropole GC/MS Parts and Supplies Engineered from the ground up for ease-of-use and routine high performance operation, the 7000A Triple Quadrapole GC/MS delivers advanced high-speed GC/MS/MS quantitation for ultra-trace analysis of even the most complex samples. Combined with the Agilent 7890 GC, the result is an optimally robust GC/MS/MS system. Gas Filters Description Chemical Ionization Gas Purifier Big Universal Trap, 1/8 in. fittings, Helium (Ar/Me) Big universal trap, 1/8 in. fittings, Nitrogen Mounting clip Part No. G1999-80410 RMSH-2 RMSN-2 UMC-2 Foreline Pump Supplies Description Diffusion pump fluid, 18.5 mL Foreline pump oil, P3, 0.5 L Rough pump inlet flange Oil return kit Pump oil drip pan Oil mist exhaust filter Oil mist filter for RV5 pump 330 GC AND GC/MS www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 Part No. 6040-0809 6040-0621 0905-1463 3162-1057 G1946-00034 G1099-80039 G6600-80043 7000A Triple Quadropole GC/MS Series Maintenance Supplies Low noise EM horn, G3170-80103 Description Abrasive sheets Alumina powder, abrasive, 1 kg Cloths, lint-free Lint-free industrial wipes, 100% cotton Cotton swabs Nylon gloves, lint-free, large Nylon gloves, lint-free, small High vacuum grease, 25 g Electron multiplier replacement horn Low noise EM horn Filament assembly, high temperature (EI) Filament assembly (CI) Micro ion vacuum gauge Replacement glass bulb for PFTBA and PFDTD test sample Part No. 5061-5896 8660-0791 05980-60051 9310-4828 5080-5400 8650-0030 8650-0029 6040-0289 05971-80103 G3170-80103 G3170-60050 G1099-80053 G3170-80001 G3170-80002 Filament assembly (EI), G3170-60050 PARTS AND SUPPLIES 331 240-MS Ion Trap 240-MS Ion Trap Parts and Supplies The Agilent 240-MS Ion Trap delivers unparalleled capabilities for both research and routine applications. Advanced ionization, including positive and negative chemical ionization, improves selectivity and limits of detection. Enhanced scanning techniques ensure compound confirmation. The MS/MS and MSn reduce matrix influences and provide more detailed structural information. The software comes with a full complement of productivity, reporting, and regulatory compliance tools. • Accurate identification and quantification of trace analytes • Unsurpassed sensitivity (200 femtogram OFN full scan) • Choice of internal or external ionization configurations • Powerful MS/MS and CI options • Low maintenance and high reliability • Intuitive software for increased productivity 240-MS Ion Trap Parts and Supplies Description Manifold O-ring Transfer line inner O-ring Transfer line outer O-ring Internal filaments (2 filaments on one disk) Internal transfer line tip External filament (single filament) Electrode, end cap, Silchrom Electrode set kit, Silchrom, DFC (inert) tested Includes 2 end cap electrodes, 1 RF electrode, cleaning instructions Electrode, RF, Silchrom Spacer, RF, Silco-quartz Electron multiplier Transfer line assembly upgrade field kit Contains a complete transfer line and side-mounted block for vacuum manifold EPA volatile kit for EPA methods 524.2 & 8260B ChromatoProbe microvials, 100/pk 332 GC AND GC/MS www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 Part No. 393010924 393010920 393010918 392017401 393171201 393161001 393164493 9300003590 393167593 393053502 393175101 393101291 393082491 392567111 240-MS Ion Trap 240-MS Ion Trap Parts and Supplies Description Part No. GC/MS Standards Evaluation standard (Internal EI & CI) 2 pg/µL OFN, 5 pg/µL Test standard for external EI (5 pg/µL OFN) Benzophenone CI sensitivity standard 50 pg/mL Test standard for external NCI (1 pg /µL DFB) Tuning calibration compound PFTBA (FC-43) GC/MS column test mix 393112601 393112702 392030500 393113001 392035300 392027300 Vacuum Supplies Oil mist exhaust filter, DS42 Oil mist eliminator Replacement cartridge for oil exhaust filter, 2/pk Foreline (roughing) pump oil, 1 L Premium foreline (roughing) pump oil, 1 L IDP-3 dry scroll pump tip seal maintenance kit IDP-3 dry scroll replacement module 393847701 2735000500 2710100200 8829951700 8829953800 2710100400 2710100500 PARTS AND SUPPLIES 333 220-MS 220-MS Parts and Supplies The 220-MS is a high sensitivity, flexible gas chromatograph/mass spectrometer that delivers outstanding qualitative and quantitative data in a range of applications. This simple and robust system is easy to operate and maintain. • Accurately identify and quantify trace analytes • Take advantage of powerful CI and MS/MS upgrades for advanced applications • Spend less time on maintenance and more time on analysis 220-MS Parts and Supplies Description Electron multiplier assembly Exit end cap electrode, chrome Exit end cap electrode, SilChrom Filament end cap electrode, chrome Filament end cap electrode, SilChrom RF ring electrode, chrome RF ring electrode, SilChrom Complete set of SilChrom electrodes and Silco-quartz spacers Spacer, RF, quartz Spacer, RF, Silco-quartz Filament disk assembly with wire connectors Filament disk assembly User must solder on 3 wire connectors Thermocouple vacuum gauge Mass spectrometer expendable supplies kit for 2x0MS Includes PFTBA calibration compound, cal-gas glass chamber, capillary injector nut, O-rings, cotton tipped applicators, end cap insulator, vacuum pump oil Part No. 393031501 393050292 393050293 393050392 393050393 393050492 393050493 393001991 393053501 393053502 393060191 392043700 2722990700 393011391 GC/MS Standards Hexachlorobenzene EI sensitivity standard 100 pg/mL Benzophenone CI sensitivity standard 50 pg/mL Tuning calibration compound PFTBA (FC-43) Hexachlorobenzene EI sensitivity standard 2 pg/mL GC/MS column test mix 334 GC AND GC/MS www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 392027500 392030500 392035300 392047100 392027300 GC/MS Standards GC/MS Standards GC/MS Analyzer Kit Standards MS standards Description GC/MS semivolatiles analyzer checkout mixture GC/MS pesticide analyzer internal standard Pesticide analyzer checkout solution Pesticide checkout standard, 100 µg/L, 3 x 1 mL GC/MS toxicology checkout mixture Residual solvent revised method 467, class C Residual solvent revised method 467, class 1 Butanetriol internal standard #1 for biodiesel Tricaprin internal standard #2 for biodiesel Part No. 5190-0473 5190-0472 5190-0468 5190-0494 5190-0471 5190-0493 5190-0490 5982-0024 5982-0025 PARTS AND SUPPLIES 335 GC/MS Standards MS Test and Performance Samples Description Part No. 5975 Series 5973 Series 5972 Series 5971 Series ] ] ] ] ] ] ] ] ] ] GCD 7000 Series Tuning Samples EI Tune CI Tune PFTBA sample, certified, 10 g, 5.32 mL 8500-0656 PFTBA MS Sample Kit, 0.942 g, 0.5 mL 05971-60571 PFDTD calibrant 8500-8510 ] ] ] ] ] ] ] Performance Verification Samples EI OFN, 1 pg/µL Hexachlorobenzene 10 pg/µL, 1 ng/µL Methyl stearate (in methanol); 1 ng/µL, 2 ea Sample A, 10 ng/µL Negative Mode CI OFN, 100 fg/µL Positive Mode CI Benzophenone, 100 pg/µL 5188-5348 8500-5808 ] ] 05990-60075 05970-60045 5188-5347 8500-5440 ] ] ] ] ] 5188-5357 8500-5995 8500-5851 05970-60045 ] ] ] ] ] ] ] ] ] ] ] ] ] ] Checkout Samples HighMass PHFT, 100 pg/µL Semi-Volatile GC/MS tuning standard, DFTPP Volatile p-Bromofluorobenzene (BFB), 25 µg/mL Evaluation sample Solution of dodecane, biphenyl, p-cholorodiphenyl, and Methyl palmitate in isooctane. Six 1.0 mL ampoules: 4 at 10 ng/µL, 1 at 100 ng/µL, 1 at 100 pg/µL. Tips & Tools Each GC/MS has a specific test and performance sample. Refer to the chart above for the exact sample. All volumes are approximately 0.5-1 mL unless otherwise specified. 336 GC AND GC/MS www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 ] ] GC Parts and Supplies for Varian Instruments GC Parts and Supplies for Varian Instruments Agilent now provides replacement parts and supplies for GC instruments formerly manufactured by Varian. The following section includes ordering information for GC injectors, detectors and GC/MS systems. Injector Replacement Parts and Supplies 1177 Split/Splitless Injector 1 2 3 4 6 5 7 8 9 10 11 Item Description 1 Injector nut Injector nut wrench 2 Knob 3 Automatic start switch 4 Septum, 9 mm BTO Long Life Advanced Green Septum pick 5 Septum purge head EFC21 (stainless steel) EFC21 (UltiMetal) EFC25 or Manual Pneumatics 6 Purge head screw 7 Graphite liner O-ring, splitless, 6.5 mm Viton liner O-ring, 6.3 mm 8 Glass liner 9 Injector body Stainless steel UltiMetal Manual 10 For replacement ferrules, see Agilent's new line of CrossLab Supplies 11 Bottom nut Part No. 392597501 390842300 392597101 390820601 8010-0217 8010-0233 8010-0201 7200008400 392597301 392597303 392597302 391866308 8004-0202 8004-0201 8004-0165 392599401 392599411 392599501 8004-0311 PARTS AND SUPPLIES 337 GC Parts and Supplies for Varian Instruments 1079 Large Volume Injector (LVI) 1a 1b 2 3 4 5 6 7 Item Description 1a Injector nut 1b Injector nut Injector nut wrench 2 Automatic start switch 3 Septum, 11.5 mm BTO Long Life Advanced Green Septum pick 4 Septum support 5 Insert ferrule 6 Glass liner 7 Injector body, EFC type Stainless steel UltiMetal 8 For replacement ferrules, see Agilent's new line of CrossLab Supplies 9 Bottom nut 8 9 To learn more about Agilent CrossLab and to request your copy of the Agilent CrossLab product catalog, visit www.agilent.com/chem/CrossLab 338 GC AND GC/MS www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 Part No. 394966601 394966601 390842300 390820601 8010-0225 8010-0241 8010-0209 7200008400 391867600 8004-0204 8004-0164 392544001 392544011 8004-0311 GC Parts and Supplies for Varian Instruments 1093 Cool On-Column (COC) Injector 1 2 3 4 5 6 7 Item Description 1 Injector nut Injector nut wrench 2 Automatic start switch 3 Septum, 11.5 mm BTO Long Life Advanced Green Septum pick 4 Septum support 5 Glass liner Default High performance On-column 6 Screw 7 Graphite/Vespel ferrule Graphite ferrule 8 Bottom nut Brass Stainless steel Part No. 394966601 390842300 390820601 8010-0225 8010-0241 8010-0209 7200008400 391821100 8004-0162 8004-0167 8004-0166 391866306 8004-0217 8010-0305 8004-0311 8004-0312 8 PARTS AND SUPPLIES 339 GC Parts and Supplies for Varian Instruments 1a 1b 2 3 4 5 1061 Packed/530 µm Capillary Column Injector Item Description 1a Injector nut 1b Injector nut Injector nut wrench 2 Septum, 9.5 mm BTO Long Life Advanced Green Septum pick 3 Automatic start switch 4 Glass liner 5 Injector body, EFC23 6 Graphite/Vespel ferrule Graphite ferrule 7 For replacement ferrules, see Agilent's new line of CrossLab Supplies 8 Bottom nut 6 7 8 340 GC AND GC/MS www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 Part No. 390812700 392595501 390842300 8010-0219 8010-0235 8010-0203 7200008400 390820601 8004-0168 392548301 8004-0217 8010-0305 8004-0311 GC Parts and Supplies for Varian Instruments 1a 1b 3 2 4 1041 Packed/Wide Bore On-Column (PWOC) Injector Item Description 1a Injector nut 1b Injector nut Injector nut wrench 2 Septum, 9.5 mm BTO Long Life Advanced Green Septum pick 3 Automatic start switch 4 Injector body, EFC type 5 Graphite/Vespel ferrule Graphite ferrule 6 Injector insert, stainless steel 7 For replacement ferrules, see Agilent's new line of CrossLab Supplies 8 Bottom nut Part No. 390812700 392595501 390842300 8010-0219 8010-0235 8010-0203 7200008400 390820601 392548201 8004-0217 8010-0305 392543101 8004-0311 5 6 8 7 PARTS AND SUPPLIES 341 GC Parts and Supplies for Varian Instruments Detector Replacement Parts and Supplies Thermal Conductivity Detector (TCD) Description Adapter TCD/DEFC capillary make-up Adapter TCD/DEFC reference gas kit Adapter TCD capillary make-up, MPC, 3800 TCD DEFC 14 (Non-H2), 2 channels Part No. 392585291 392585292 392560591 392561290 Flame Ionization Detector (FID) Description Tube collector Lower FID insulator 17311 FID flame tip jet, 0.010 in. FID flame tip jet with nut, 0.020 in. Crunch washer, 25/pk Tips & Tools To learn more about Agilent's complete portfolio of services, please visit www.agilent.com/chem/services 342 GC AND GC/MS www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 Part No. 394958700 2100003200 200187500 200193800 1500334701 GC Parts and Supplies for Varian Instruments Pulsed Flame Photometric Detector (PFPD) Description Photomultiplier tube (PFPD) #R647-08 O-Ring, silicone, 0.53 in. ID, PFPD PFPD light pipe Sapphire window assembly Sapphire window washer Wrench, PFPD combustor support Seal, combustor support Combustor holder (2 mm) Combustor Sulfur (2 mm), cleaned Holder, combustor, 3 mm, cleaned Combustor Phosphorus, 3 mm, cleaned Part No. 392517100 2740292400 392515500 392514500 392514300 392519200 392513800 392517800 392517600 392517901 392517700 PFPD Filter Assemblies Description Arsenic (As) Manganese (Mn) Nitrogen (N) Sulfur and Phosphorus (S and P) Phosphorus (P) Sulfur (S) Tin (Sn) Part No. 392515105 392544391 392511901 392515104 392515102 392515101 392515103 PARTS AND SUPPLIES 343 GC Parts and Supplies for Varian Instruments PFPD Nitrogen Mode Maintenance Description Photomultiplier tube, Nitrogen R-5070A O-Ring, 0.987 in. ID PFPD filter assembly, Nitrogen PFPD light pipe Sapphire window assembly Sapphire window washer Part No. 392512800 2740236100 392511901 392515500 392514500 392514300 Thermionic Specific Detector (TSD) Description TSD bead probe, unconditioned and untested TSD bead probe, conditioned and tested Upper TSD insulator #17310 TSD O-Ring, 30/pk TSD collector assembly Lower FID insulator #17311 Crunch washer, 25/pk FID flame tip jet with nut, 0.020 in. Flow tube assembly 344 GC AND GC/MS www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 Part No. 390607400 390607401 2100003100 2740928202 390607900 2100003200 1500334701 200193800 200187600 GC Parts and Supplies for Varian Instruments GC/MS System Replacement Parts and Supplies 210/220/225 GC/MS Systems Description Electron multiplier assembly Exit end cap electrode, chrome Exit end cap electrode, SilChrom Filament end cap electrode, chrome Filament end cap electrode, SilChrom RF ring electrode, chrome RF ring electrode, SilChrom Complete set of SilChrom electrodes and Silco-quartz spacers Spacer, RF, quartz Spacer, RF, Silco-quartz Filament disk assembly with wire connectors Filament disk assembly User must solder on 3 wire connectors Thermocouple vacuum gauge Mass spectrometer expendable supplies kit for 2x0MS Includes PFTBA calibration compound, cal-gas glass chamber, capillary injector nut, O-rings, cotton tipped applicators, end cap insulator, vacuum pump oil Part No. 393031501 393050292 393050293 393050392 393050393 393050492 393050493 393001991 393053501 393053502 393060191 392043700 2722990700 393011391 GC/MS Standards Hexachlorobenzene EI sensitivity standard 100 pg/mL Benzophenone CI sensitivity standard 50 pg/mL Tuning calibration compound PFTBA (FC-43) Hexachlorobenzene EI sensitivity standard 2 pg/mL GC/MS column test mix 392027500 392030500 392035300 392047100 392027300 PARTS AND SUPPLIES 345 GC Parts and Supplies for Varian Instruments 240 GC/MS and 4000 GC/MS Systems Description Manifold O-ring Transfer line inner O-ring Transfer line outer O-ring Internal filaments (2 filaments on one disk) Internal transfer line tip External filament (single filament) Electrode, end cap, SilChrom Electrode set kit, SilChrom, DFC (inert) tested Includes 2 end cap electrodes, 1 RF electrode, cleaning instructions Electrode, RF, SilChrom Spacer, RF, Silco-quartz Electron multiplier Transfer line assembly upgrade field kit Contains a complete transfer line and side-mounted block for vacuum manifold EPA volatile kit for EPA methods 524.2 & 8260B ChromatoProbe microvials, 100/pk Part No. 393010924 393010920 393010918 392017401 393171201 393161001 393164493 9300003590 393167593 393053502 393175101 393101291 393082491 392567111 GC/MS Standards Evaluation standard (Internal EI & CI) 2 pg/µL OFN, 5 pg/µL Test standard for external EI (5 pg/µL OFN) Benzophenone CI sensitivity standard 50 pg/mL Test standard for external NCI (1 pg /µL DFB) Tuning calibration compound PFTBA (FC-43) GC/MS column test mix 393112601 393112702 392030500 393113001 392035300 392027300 Vacuum Supplies Oil mist exhaust filter, DS42 Oil mist eliminator Replacement cartridge for oil exhaust filter, 2/pk Foreline (roughing) pump oil, 1 L Premium foreline (roughing) pump oil, 1 L IDP-3 dry scroll pump tip seal maintenance kit IDP-3 dry scroll replacement module 346 GC AND GC/MS www.agilent.com/chem/GC www.crawfordscientific.com l 01357 522 961 393847701 2735000500 2710100200 8829951700 8829953800 2710100400 2710100500 GC Parts and Supplies for Varian Instruments Saturn 2000 Series MS Systems Description Mass spectrometer expendable supplies kit for 2x0MS Includes PFTBA calibration compound, cal-gas glass chamber, capillary injector nut, O-rings, cotton tipped applicators, end cap insulator, vacuum pump oil Electron multiplier assembly Filament disk assembly with wire connectors Filament disk assembly User must solder on 3 wire connectors Exit end cap electrode, SilChrom Filament end cap electrode, SilChrom RF ring electrode, SilChrom Exit end cap electrode, chrome Filament end cap electrode, chrome RF ring electrode, chrome Spacer, RF, quartz Spacer, RF, Silco-quartz Complete set of SilChrom electrodes and Silco-quartz spacers Part No. 393011391 393031501 393060191 392043700 393050293 393050393 393050493 393050292 393050392 393050492 393053501 393053502 393001991 GC/MS Standards Tuning calibration compound PFTBA (FC-43) Benzophenone CI sensitivity standard 50 pg/mL Hexachlorobenzene EI sensitivity standard 2 pg/mL Hexachlorobenzene EI sensitivity standard 100 pg/mL GC/MS column test mix 392035300 392030500 392047100 392027500 392027300 Tips & Tools More information is a click away. We have a variety of educational primers, application notes, maintenance guides, and literature available from Agilent for free. To learn more, visit www.agilent.com/chem/OnlineLibrary PARTS AND SUPPLIES 347 Agilent J&W GC and GC/MS Columns AGILENT J&W GC AND GC/MS COLUMNS A legacy of confidence: The continuing story of Agilent J&W GC Columns In 2000, Agilent Technologies, the inventor of low-bleed HP-5ms columns, merged with J&W Scientific, the creator of DB-5ms – the first GC stationary phase to use arylene technology for lower column bleed. Thanks to this partnership, you can find both the renowned HP and DB column families under the Agilent J&W name. And they’re all brought to you by Agilent Technologies – a company with over 40 years of gas chromatography experience. In 2010, a new chapter began with the addition of Varian, Inc. This key acquisition enabled Agilent to expand its GC column portfolio to include three highly respected column families: • FactorFour GC columns employ advanced proprietary manufacturing techniques to ensure low background and high signal-to-noise values for your routine or trace analysis. • Select GC columns offer guaranteed performance for specific methods and applications. • PoraBOND GC columns are highly retentive Porous Layer Open Tubular (PLOT) columns. Because they do not shed any particles, they can improve the quality of your data for volatile compounds. 348 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Agilent J&W GC and GC/MS Columns The Agilent J&W column difference Low bleed and high inertness for sensitivity and performance Column bleed can decrease data integrity, reduce uptime, and shorten column life, while column activity contributes to severe peak tailing, compound loss, and degradation of active compounds, all of which raise detection limits and reduce method linearity. Agilent J&W columns have the widest range of GC/MS and Ultra Inert stationary phases proven to deliver consistent column inertness, exceptionally low column bleed, and high upper temperature limits to ensure accurate peak identification and quantification, improved sensitivity, and extended linearity. Better precision for better results and greater productivity Every Agilent J&W GC column adheres to tight retention factor (k) specifications, promoting consistent retention and separation. They also feature narrow retention indexes and a high number of theoretical plates per meter, both of which provide narrow peaks, improve the resolution of closely eluting peaks, and simplify data interpretation. The industry's tightest quality control specifications Agilent's stringent testing ensures reliable qualitative and quantitative results – even for your most challenging compounds. For example, we measure peak height ratios for acids and bases to achieve top performance for the widest range of analytes. In 2008, Agilent also ushered in a new era of column inertness QC testing with the industry's most rigorous test probe mixture. AGILENT J&W GC AND GC/MS COLUMNS 349 Agilent J&W GC and GC/MS Columns Tighter GC Column Performance Criteria Feature Narrow Retention Index and Retention Factor Window Advantage Benefit � Highest level of column-to-column reproducibility � Confidence in analytical results � Minimal method adjustment when changing columns � Improved sample throughput, reduced downtime � Specify J&W chemistry for intra-company methodologies Increased Plates per Meter � Highest level of "resolving power" � Improved sample throughput Lowest Bleed � Increased analytical sensitivity for all detectors Highest Degree of Inertness 350 GC AND GC/MS � Confidence in method transfer and intra-company results � Accurate quantification � Potentially shorter run times � Improved detection limits � Reliable compound identification � Fast baseline stabilization � Faster column exchange � Minimized conditioning time � Increased sample throughput � Excellent thermal stability � Increased column lifetime, reduced downtime � Increased sample throughput � Better peak shape for active compounds � Minimum compound adsorption � Improved detection limit, more accurate quantification, and more instrument uptime � More accurate quantification for trace samples and unknown sample screening www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Agilent J&W GC and GC/MS Columns Agilent J&W Ultra Inert GC Capillary Columns The only GC columns that deliver on the promises of consistent column inertness and exceptionally low column bleed Agilent J&W Ultra Inert GC columns give you outstanding sensitivity and peak shape, allowing you to confidently perform trace-level analysis of acids, bases, and other active compounds. Like all Agilent columns, Ultra Inert GC columns undergo tight QC testing procedures. However, Ultra Inert columns must also pass through a more difficult set of test parameters, including: • A demanding test probe mixture that contains compounds with low molecular weights, low boiling points, and no steric shielding of active functional groups, which prevents masking effects and reveals true column quality. • Testing at lower isothermal temperatures (65°C vs. 120°C for GC/MS columns). Lowertemperature testing decreases the kinetic energy of probes in the mobile phase, preventing molecules from sweeping past active sites on the column. This allows a true evaluation of column surface activity and ensures consistent column inertness. Together, these conditions enhance the opportunity for solute/column interactions, and expose column deficiencies that traditional GC/MS testing might not detect. AGILENT J&W GC AND GC/MS COLUMNS 351 Agilent J&W GC and GC/MS Columns Agilent J&W High Efficiency GC Capillary Columns High efficiency, high throughput, and high resolution without the high costs This leading-edge column technology is ideal for applications that require faster run times, such as high-throughput screening, fast process monitoring, and fast method development. In fact, Agilent High Efficiency columns can reduce your sample run time by 50% or more without compromising resolution. Unlike other manufacturers' 0.1 mm ID columns, Agilent High Efficiency Capillary GC columns are compatible with all standard-pressure capillary GC and GC/MS instruments – without expensive high-pressure modifications. They also give you: • The flexibility to choose between helium and hydrogen carrier gases. You can stay with a helium carrier if you wish to simplify method development, or switch to a hydrogen carrier to further reduce your analysis time. • The ability to separate samples using less carrier gas, which can lead to longer intervals between cylinder changes, increased uptime, and a lower cost per sample. In addition, these flexible columns easily adapt to a wide variety of environmental, petrochemical, flavor/fragrance, clinical toxicology, and pharmaceutical sample matrices. 352 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Agilent J&W GC and GC/MS Columns Agilent J&W FactorFour GC Columns Low-bleed performance for all areas of GC and GC/MS analysis With Agilent J&W FactorFour columns, you get the throughput you need to analyze more compounds in less time – and the analytical accuracy you need to get the right results every time. They are manufactured from detailed specifications and high-quality materials to ensure the reproducibility, low bleed, and high inertness that today’s applications demand. FactorFour columns are available in a variety of general and application-specific phases – including VF-WAXms, the only GC/MS-compatible Wax column – to meet your lab’s every requirement. Double your sample throughput and reduce your cost per analysis with FactorFour 0.15 mm ID columns In addition to standard dimensions, FactorFour columns are available in an extended range of 0.15 mm ID choices specifically designed to reduce run times and increase throughput. AGILENT J&W GC AND GC/MS COLUMNS 353 Agilent J&W GC and GC/MS Columns Agilent J&W LTM Column Modules Shorten analytical cycle times and boost your high speed gas chromatography capabilities Agilent J&W LTM column modules combine a high quality fused silica capillary column with heating and temperature sensing components for a low thermal mass column assembly. The LTM column module contains a patented design which heats and cools the column very efficiently for significantly shorter analytical cycle times compared to conventional air-bath GC oven techniques, while simultaneously using less power. Agilent offers LTM technology for our popular 7890 and 6890 Series GC systems, as well as the new 5875T GC/MS. All LTM column modules are packaged with: • Two 1 m guard columns (one each for the inlet and detector) made from deactivated fused silica tubing of the same ID as the analytical column • Five non-reusable ferrules that fit the dimensions of the analytical and guard columns Tips & Tools Agilent LTM column module technology is compatible with metal capillary columns. However, LTM modules are generally not recommended for fast GC applications because of their poor cooling performance compared to fused silica capillaries. 354 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Agilent J&W GC and GC/MS Columns Agilent J&W LTM Column Modules for 7890 and 6890 GC Systems This groundbreaking column technology is designed specifically for Agilent 7890A and 6890 series gas chromatographs, and delivers: • The capacity to run up to four column modules simultaneously – with four different temperature programs – to maximize your productivity • Rapid temperature programming rates of up to 1800°C/min for higher analysis speeds • Faster cooling times – as low as one minute or less – to decrease idling and downtime • Shorter analytical cycle times than conventional air-bath GC oven techniques • Excellent retention time repeatability and performance – comparable to conventional GC • Strong synergy with Agilent Capillary Flow Technology, which can enhance your ability to perform multi-dimensional and comprehensive GC • The ability to use the same 6890/7890 GC injectors and detectors with little change to your existing methods Most Agilent J&W Capillary GC columns – including Wall Coated Open Tubular (WCOT) and Porous Layer Open Tubular (PLOT) columns – can be used for LTM column modules. Module assemblies are available in two sizes that deliver equal chromatographic quality: • 5 inch diameter (standard): features faster cooling speeds, and is recommended for most applications. The 5 inch format allows two column modules to be installed per Agilent LTM system, and can be used with any capillary GC column up to 30 m long. • 3 inch diameter (small): enables multidimensional GC applications by allowing up to four column modules to be installed per Agilent LTM system. The 3 inch format is limited to capillary GC columns with a 0.32 mm or smaller ID, and is not recommended for fragile capillary columns or PLOT columns. Module sizes can also be mixed; for example, you can use one 5 inch module with either one or two 3 inch modules. Tips & Tools LTM column modules should never be programmed beyond the GC column temperature limits recommended by Agilent. For very fast ramping applications (e.g. 600°C/min), limiting the maximum temperatures to 10-20°C below the GC column temperature limits can increase the lifetime of the column modules. AGILENT J&W GC AND GC/MS COLUMNS 355 Agilent J&W GC and GC/MS Columns NEW! Agilent J&W LTM Column Modules for 5975T Transportable GC/MS Systems This groundbreaking column technology is designed specifically for Agilent 5975T GC/MS systems. These modules include integrated 3 inch LTM capillary column toroid assembly with heated transfer lines, cooling fan assembly and sheet metal enclosure. Replacement column toroid assemblies are also available. Benefits of the LTM column modules include: • Rapid temperature programming rates of up to 1200°C/min • Faster heating and cooling times – as low as one minute or less – for more rapid analytical cycle times than standard air-bath GC oven techniques • Excellent retention time repeatability and performance comparable to conventional GC • Less power consumption for longer in-field operation • Integrated module design to facilitate easy column module change in the field The entire assembly is leak tested and ready for installation into your Agilent 5975T instrument. LTM column modules for the 5975T include: • 2 heated transfer lines • Transferline base assembly • 3 inch LTM column toroid assembly • 2 ultimate unions • Cooling fan assembly • Sheet metal enclosure For more information, visit www.agilent.com/chem/LTMcol 356 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Agilent J&W GC and GC/MS Columns Agilent J&W LTM Column Modules for 5975T Transportable GC/MS Systems Phase DB-5ms Ultra Inert ID (mm) 0.18 0.25 HP-5ms Ultra Inert 0.18 0.25 DB-1 DB-1ms 0.25 0.18 0.25 DB-1ht 0.25 HP-1ms 0.18 0.25 DB-5ms 0.18 0.25 DB-5ht 0.25 HP-5ms DB-35ms 0.25 0.18 0.25 DB-17ms 0.18 0.25 DB-225ms 0.25 DB-1701 DB-WAX 0.25 0.25 HP-INNOWax 0.18 0.25 0.25 DB-FFAP DB-608 DB-VRX DB-624 HP-VOC 0.18 0.18 0.25 0.18 0.25 0.20 Length (m) 20 15 30 20 15 30 30 20 15 30 15 30 20 30 15 20 15 30 15 30 30 20 15 30 20 15 30 15 30 30 15 30 20 30 15 30 20 20 30 20 30 30 Film (µm) 0.18 0.25 0.25 0.18 0.25 0.25 0.25 0.18 0.25 0.25 0.10 0.10 0.18 0.10 0.25 0.18 0.25 0.25 0.10 0.10 0.25 0.18 0.25 0.25 0.18 0.25 0.25 0.25 0.25 0.25 0.50 0.50 0.18 0.25 0.25 0.25 0.18 1.00 1.40 1.00 1.40 1.12 Toroid Assembly 221-5522UILTM 222-5512UILTM 222-5532UILTM 29091S-577UILTM 29091S-431UILTM 29091S-433UILTM 222-1032LTM 221-0122LTM 222-0112LTM 222-0132LTM 222-1111LTM 222-1131LTM 29091S-677LTM 29091S-833LTM 29091S-931LTM 221-5522LTM 222-5512LTM 222-5532LTM 222-5731LTM 222-5711LTM 29091S-433LTM 221-3822LTM 222-3812LTM 222-3832LTM 221-4722LTM 222-4712LTM 222-4732LTM 222-2912LTM 222-2932LTM 222-0732LTM 222-7013LTM 222-7033LTM 29091N-577LTM 29091N-133LTM 222-3212LTM 222-3232LTM 221-6822LTM 221-1524LTM 222-1534LTM 221-1324LTM 222-1334LTM 29091R-303LTM Column Module G3900-63014 G3900-63031 G3900-63005 G3900-63039 G3900-63038 G3900-63001 G3900-63002 G3900-63009 G3900-63016 G3900-63017 G3900-63018 G3900-63019 G3900-63040 G3900-63041 G3900-63042 G3900-63013 G3900-63030 G3900-63004 G3900-63033 G3900-63032 G3900-63007 G3900-63011 G3900-63026 G3900-63027 G3900-63012 G3900-63028 G3900-63029 G3900-63022 G3900-63023 G3900-63003 G3900-63034 G3900-63035 G3900-63036 G3900-63008 G3900-63024 G3900-63025 G3900-63015 G3900-63006 G3900-63021 G3900-63010 G3900-63020 G3900-63037 AGILENT J&W GC AND GC/MS COLUMNS 357 Agilent J&W GC and GC/MS Columns Choosing a Capillary GC Column The first step should always be to refer to what has already been done. Our chemists have put together a variety of resources to help you find the right column for your analysis. • Chromatograms – Find some of the more common chromatograms with column recommendations and method parameters for your reference in this catalog. For a more extensive chromatogram library and a compound search function, go to www.agilent.com/chem, then click Library. • Method Guides – We've evaluated the most common Environmental/EPA methods, ASTM methods, USP methods and general compound analyses and compiled simple guides which specify the best column recommendation for these methods. • Retention Data Lists – We've analyzed hundreds of compounds on several different phases to help you determine which column will be the best choice for your list of compounds. • Column Selection Guide – Our Agilent J&W GC Column Selection Guide gives you helpful hints for choosing a stationary phase, selecting the right column dimensions, developing temperature programs and determining the right inlet and detector for the application. To order this guide, use publication number 5989-6159EN. Our Technical Support Chemists have more than 100 years of combined experience running samples and developing methods. We are the gas chromatography column experts and we are at your disposal. Send in questions via the Technical Support form on our website www.agilent.com/chem, via email at gc-column-support@agilent.com, or contact your local Agilent office or Authorized Agilent Distributor. 358 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Ultra Inert Capillary GC Columns Tips & Tools Agilent Ultra Inert Liners are the perfect companion to Agilent J&W Ultra Inert GC Columns, providing reproducible inertness liner after liner, maintained through a sequence of samples, and for a range of analytes. Turn to page 261. Agilent J&W Ultra Inert Capillary GC Columns • Individually tested with a unique, demanding test probe mixture • Consistent column inertness performance • Exceptionally low column bleed • Great peak shapes for challenging active analytes • Excellent signal-to-noise ratios • Minimum compound adsorption or degradation • Support of 0.18 mm ID column configuration for higher sample throughput Ultra Inert Chromatograms Environmental Trace Level Polycyclic Aromatic Hydrocarbon (PAH) Analyses US EPA Method 8270 Short Mix US EPA Method 551.1 Page 589 Page 589 Page 590 Life Sciences Benzodiazepines I Page 671 Food, Flavors and Fragrances Lavender Oil Characterization Page 622 DB-1ms Ultra Inert ID (mm) 0.18 0.25 0.32 Length (m) 20 15 30 60 15 30 Film (µm) 0.18 0.25 0.25 0.25 0.25 0.25 Temp Limits (°C) -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 7 in. Cage 121-0122UI 122-0112UI 122-0132UI 122-0162UI 123-0112UI 123-0132UI 5 in. Cage 122-0112UIE 122-0132UIE AGILENT J&W GC AND GC/MS COLUMNS 359 Ultra Inert Capillary GC Columns HP-1ms Ultra Inert ID (mm) 0.18 0.25 Length (m) 20 15 30 0.32 15 25 30 Film (µm) 0.18 0.25 0.25 0.50 1.00 0.25 0.52 0.25 1.00 Temp Limits (°C) -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 7 in. Cage 19091S-677UI 19091S-931UI 19091S-933UI 19091S-633UI 19091S-733UI 19091S-911UI 19091S-612UI 19091S-913UI 19091S-713UI 5 in. Cage 19091S-677UIE 19091S-931UIE 19091S-933UIE Film (µm) 0.18 0.25 0.25 0.25 0.25 Temp Limits (°C) 50 to 340/360 50 to 340/360 50 to 340/360 50 to 340/360 50 to 340/360 19091S-733UIE 19091S-913UIE DB-35ms Ultra Inert ID (mm) 0.18 0.25 0.32 360 GC AND GC/MS Length (m) 20 15 30 15 30 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com 7 in. Cage 121-3822UI 122-3812UI 122-3832UI 123-3812UI 123-3832UI Ultra Inert Capillary GC Columns DB-5ms Ultra Inert ID (mm) 0.18 Length (m) 20 0.25 40 15 25 30 50 60 0.32 30 60 Film (µm) 0.18 0.36 0.18 0.25 1.00 0.25 0.25 0.50 1.00 0.25 0.25 1.00 0.25 0.50 1.00 1.00 Temp Limits (°C) -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 7 in. Cage 121-5522UI 121-5523UI 121-5542UI 122-5512UI 122-5513UI 122-5522UI 122-5532UI 122-5536UI 122-5533UI 122-5552UI 122-5562UI 122-5563UI 123-5532UI 123-5536UI 123-5533UI 123-5563UI 5 in. Cage 122-5532UIE 122-5533UIE 123-5532UIE 7890/6890 LTM Module 121-5522UILTM 121-5523UILTM 5975T LTM Toroid 221-5522UILTM 122-5512UILTM 122-5513UILTM 122-5522UILTM 122-5532UILTM 122-5536UILTM 122-5533UILTM 222-5512UILTM 222-5532UILTM 123-5532UILTM 123-5536UILTM 123-5533UILTM HP-5ms Ultra Inert ID (mm) Length (m) Film (µm) Temp Limits (°C) 7 in. Cage -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 19091S-577UI 19091S-431UI 19091S-433UI 19091S-133UI 19091S-233UI 19091S-436UI 19091S-413UI 19091S-213UI 5 in. Cage 7890/6890 LTM Module 5975T LTM Toroid 19091S-577UILTM 19091S-431UILTM 19091S-433UILTM 19091S-133UILTM 19091S-233UILTM 29091S-577UILTM 29091S-431UILTM 29091S-433UILTM HP-5ms Ultra Inert 0.18 0.25 0.32 20 15 30 60 30 0.18 0.25 0.25 0.50 1.00 0.25 0.25 1.00 19091S-433UIE 19091S-233UIE 19091S-413UILTM 19091S-213UILTM AGILENT J&W GC AND GC/MS COLUMNS 361 Guard Columns Guard Columns Tips & Tools Column contamination from sample matrix components is the number one cause of column failure. Use Agilent DuraGuard GC columns with built-in guard if you do not want to use column connectors. • Columns with "built-in" guard columns, no press-fit connectors • Minimize front-end contamination and increase column lifetime • Aid in focusing sample onto the front of the column for better peak shape • Minimize MSD contamination originating from the column (when used in transfer line) Guard columns (or retention gaps) are often added to the front of the analytical column to protect against contamination, or to act as a band-focusing device for liquid samples introduced by on-column and splitless injection techniques. When resolution or response in a chromatogram diminishes, remove a coil from the guard column so that peak shapes will improve. By removing a coil, the column length is shortened and peaks will elute somewhat faster. For best results, check the integration time windows of your data system. DuraGuard DuraGuard columns of different phases and dimensions are available through Agilent Technologies' custom column shop. Any DB polysiloxane or GC/MS phase can be made as a DuraGuard column with 0.18 mm ID or larger fused silica tubing. Ask for a custom column quote using part number 100-2000. Specify the phase, ID, length, and film thickness of analytical column, and desired length of DuraGuard. DuraGuard Phase DB-1 DB-XLB DB-5ms DB-5.625 DB-1701 DB-624 362 GC AND GC/MS ID (mm) 0.25 0.25 0.25 Length (m) 30 30 30 0.32 0.53 0.18 0.25 0.53 0.53 60 30 30 20 30 30 30 Film (µm) 0.25 0.25 0.25 0.50 1.00 0.25 1.00 0.50 0.36 0.25 1.00 3.00 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Guard Length (m) 10 10 10 10 10 10 10 10 5 5 10 5 Part No. 122-1032G 122-1232G 122-5532G 122-5536G 122-5533G 122-5562G 123-5533G 125-5537G 121-5622G5 122-5631G5 125-0732G 125-1334G5 Guard Columns EZ-Guard EZ-Guard columns combine a FactorFour column with a built-in guard column. The first five or ten meter section of the EZ-Guard column (guard length depends on the column you select) is not coated with stationary phase, but has been deactivated. The lack of a column connection between the guard and analytical section results in a 100% leak-free column. Every EZ-Guard column features a unique uncoated and deactivated outlet section, approximately 100 cm long, which acts as an integrated transfer line. This provides a shorter stabilization time with all types of detectors. The absence of a stationary phase in the last part of the column significantly reduces background noise. The impact of water, oxygen or other polar or aggressive components that move through the end of the column at high temperature will also be greatly reduced. EZ-Guard Phase VF-1ms ID (mm) 0.20 0.25 Length (m) 12 30 VF-5ms 0.25 15 30 VF-Xms 0.53 0.25 60 30 30 VF-17ms 0.25 30 VF-1701ms 0.25 30 VF-35ms 0.25 30 Film (µm) 0.33 0.25 0.25 0.25 0.25 0.25 0.50 0.50 0.25 0.25 0.10 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 Guard Length (m) 5 5 10 5 5 10 5 10 5 10 10 5 10 5 10 5 10 5 10 Part No. CP9023 CP9010 CP9011 CP9021 CP9012 CP9013 CP9014 CP9015 CP9016 CP9020 CP9022 CP9018 CP9019 CP9024 CP9025 CP9176 CP9177 CP9026 CP9027 AGILENT J&W GC AND GC/MS COLUMNS 363 Low-bleed GC/MS Columns Low-bleed GC/MS Columns Tips & Tools Agilent MS Certified Liners are lot-tested with MSD and FID for superior acid/base deactivation, response linearity and peak symmetry. Turn to page 262. There is a rapidly increasing population of benchtop GC/MS instruments in analytical laboratories that analyze a widening range of trace level, higher temperature samples. These samples require increasingly inert, lower bleed, higher temperature columns. In response to this growing need, Agilent Technologies designed several "ms" columns to chromatograph a broader range of low level samples and generate lower bleed even at higher temperatures. What makes an Agilent J&W low bleed column unique? What makes an Agilent J&W low bleed column exceptional? Unique polymer chemistry and proprietary surface deactivation, both of which have contributed to columns that adhere to the tightest quality control specifications in the industry for bleed, inertness, selectivity and efficiency. Agilent J&W "ms" columns utilize special surface deactivation and siloxane chemistries which enhance the chromatographic performance of siloxane polymers. While some of the GC/MS phases utilize different polymer chemistries, their selectivity mimics the standard polysiloxane phases and offers the advantages of low column bleed and, in some cases, extended temperature ranges. The mass spectrum of septum bleed can look very much like GC column bleed, so the two are often confused. An easy way to tell the two apart: column bleed will be a rise in the baseline, not peaks. If you see bleed peaks, these generally come from lower quality septa or septa being used beyond their operating limits. To minimize septa contributions to background bleed, use quality Agilent BTO, Long Life, or Advanced Green septa. 364 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Low-bleed GC/MS Columns DB-1ms CH3 O Si CH3 100% Structure of DB-1ms • 100% Dimethylpolysiloxane • Identical selectivity to DB-1 • Non-polar • Very low bleed characteristics, ideal for GC/MS • Improved acid performance compared to standard 100% Dimethylpolysiloxane columns • Improved signal-to-noise ratio for better sensitivity and mass spectral integrity • 340/360°C upper temperature limit • Excellent general purpose column • Bonded and cross-linked • Solvent rinsable DB-1ms Chromatograms Life Sciences Drug Screen Page 673 DB-1ms ID (mm) 0.10 Length (m) 10 20 0.18 0.20 0.25 0.32 20 12 25 15 30 60 15 30 60 Film (µm) 0.10 0.40 0.10 0.40 0.18 0.33 0.33 0.25 0.10 0.25 0.25 0.25 0.10 0.25 0.25 Temp Limits (°C) -60 to 340/360 -60 to 340/360 -60 to 340/360 -60 to 340/360 -60 to 340/360 -60 to 340/350 -60 to 340/350 -60 to 340/360 -60 to 340/360 -60 to 340/360 -60 to 340/360 -60 to 340/360 -60 to 340/360 -60 to 340/360 -60 to 340/360 7 in. Cage 127-0112 127-0113 127-0122 127-0123 121-0122 128-0112 128-0122 122-0112 122-0131 122-0132 122-0162 123-0112 123-0131 123-0132 123-0162 5 in. Cage 121-0122E 128-0122E 122-0112E 122-0132E 7890/6890 LTM Module 127-0112LTM 127-0113LTM 127-0122LTM 127-0123LTM 121-0122LTM 128-0112LTM 128-0122LTM 122-0112LTM 122-0131LTM 122-0132LTM 5975T LTM Toroid 221-0122LTM 222-0112LTM 222-0132LTM 123-0112LTM 123-0131LTM 123-0132LTM AGILENT J&W GC AND GC/MS COLUMNS 365 Low-bleed GC/MS Columns HP-1ms CH3 O • 100% Dimethylpolysiloxane • Identical selectivity to HP-1 • Non-polar • Low bleed characteristics • Excellent general purpose column • Improved signal-to-noise ratio for better sensitivity and mass spectral integrity • Bonded and cross-linked • Solvent rinsable Si CH3 100% Structure of HP-1ms HP-1ms Chromatograms Environmental Nitrogen Containing Herbicides (EPA Method 507) Page 586 HP-1ms ID (mm) 0.18 0.20 0.25 0.32 Length (m) 20 25 15 30 60 15 25 30 60 366 GC AND GC/MS Film (µm) 0.18 0.33 0.25 0.10 0.25 0.50 1.00 0.25 0.25 0.52 0.25 1.00 0.25 Temp Limits (°C) -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 7 in. Cage 19091S-677 19091S-602 19091S-931 19091S-833 19091S-933 19091S-633 19091S-733 19091S-936 19091S-911 19091S-612 19091S-913 19091S-713 19091S-916 5 in. Cage 19091S-677E 19091S-602E 19091S-931E 19091S-933E 19091S-733E 19091S-936E 19091S-913E www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com 7890/6890 LTM Module 19091S-677LTM 19091S-602LTM 19091S-931LTM 19091S-833LTM 19091S-933LTM 19091S-633LTM 19091S-733LTM 19091S-911LTM 19091S-612LTM 19091S-913LTM 19091S-713LTM 5975T LTM Toroid 29091S-677LTM 29091S-931LTM 29091S-833LTM 29091S-433LTM Low-bleed GC/MS Columns VF-1ms CH3 O Si CH3 100% Structure of VF-1ms • Lowest guaranteed bleed specification for trace analysis with MS • Wide range of applications ensures near universal applicability • Highly inert for accurate analysis, even at trace levels VF-1ms is a highly inert, non-polar, low bleed GC column providing increased sensitivity over a broad array of applications. The 100% dimethylpolysiloxane phase delivers a guaranteed bleed specification of 1 pA @ 325°C (30 m, 0.25 mm, 0.25 µm). The VF-1ms comes with an EZ-GRIP to simplify installation, coupling and operation of capillary columns. For guaranteed performance, the retention index, efficiency, selectivity and bleed is measured and specified on the test report supplied with every column. VF-1ms is also available with 0.15 mm ID for fast GC and GC/MS that can double sample throughput when compared to 0.25 and 0.32 mm ID columns. VF-1ms Chromatograms Food, Flavors and Fragrances Triglycerides C28-C54 Separation of TMS-derivatized sugars Page 639 Page 630 Column shown with EZ-GRIP VF-1ms ID (mm) 0.10 Length (m) 10 20 0.15 10 15 20 Film (µm) 0.10 0.40 0.10 0.40 0.15 0.15 0.15 0.60 Temp Limits (°C) -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 7 in. Cage CP8900 CP8901 CP8902 CP8903 CP9030 CP5881 CP9031 CP9032 5 in. Cage CP9032I5 (Continued) AGILENT J&W GC AND GC/MS COLUMNS 367 Low-bleed GC/MS Columns VF-1ms ID (mm) 0.20 0.25 Length (m) 12 25 15 25 30 50 60 0.32 15 25 30 50 60 0.53 15 30 368 GC AND GC/MS Film (µm) 0.33 0.33 0.10 0.25 1.00 0.25 0.40 0.10 0.25 1.00 0.25 0.40 0.25 1.00 0.10 0.25 1.00 0.25 0.40 0.10 0.25 0.50 1.00 0.25 0.40 0.25 1.00 0.50 1.50 0.50 1.00 1.50 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Temp Limits (°C) -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 310/335 7 in. Cage CP8904 CP8905 CP8906 CP8907 CP8908 CP8909 CP8910 CP8911 CP8912 CP8913 CP8914 CP8915 CP8916 CP8917 CP8918 CP8919 CP8920 CP8921 CP8922 CP8923 CP8924 CP8925 CP8926 CP8927 CP8928 CP8929 CP8930 CP8965 CP8967 CP8968 CP8969 CP8970 5 in. Cage CP8906I5 CP8907I5 CP8908I5 CP8911I5 CP8912I5 CP8913I5 CP8916I5 CP8917I5 CP8918I5 CP8920I5 Low-bleed GC/MS Columns DB-5ms O CH3 CH3 Si Si CH3 CH3 CH3 O m Structure of DB-5ms Si CH3 n • Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane • Non-polar • Very low bleed characteristics, ideal for GC/MS • Excellent inertness for active compounds • Improved signal-to-noise ratio for better sensitivity and mass spectral integrity • Bonded and cross-linked • Solvent rinsable • MSD testing and certification available • Exact replacement of HP-5TA • Close equivalent to USP Phase G27 • Test mix available DB-5ms Chromatograms Environmental Diesel Fuel EPA Air Analysis Method TO-15 (1 ppbV Standard) EPA Method 525.2 EPA Method 8061 (Phthalate Esters) Formaldehyde, 50ppb Organochlorine Pesticides II EPA Method 8081A Organophosphorous Pesticides I, EPA Method 8141A Phenols Sulfur in Air Page 570 Page 612 Page 598 Page 599 Page 613 Page 575 Page 583 Page 601 Page 613 Industrial Chemicals Amines and Nitriles Phenols II Polyethyleneamines Substituted Anilines Page 646 Page 666 Page 646 Page 665 Life Sciences Narcotics Page 679 AGILENT J&W GC AND GC/MS COLUMNS 369 Low-bleed GC/MS Columns DB-5ms ID (mm) 0.18 0.20 0.25 Length (m) 20 40 12 25 50 15 25 30 50 60 0.32 15 25 30 60 0.53 370 15 30 GC AND GC/MS Film (µm) 0.18 0.36 0.18 0.33 0.33 0.33 0.10 0.25 0.50 1.00 0.25 0.40 0.10 0.25 0.50 1.00 0.25 0.10 0.25 1.00 0.10 0.25 1.00 0.52 0.10 0.25 0.50 1.00 0.10 0.25 0.50 1.00 1.50 0.50 1.00 1.50 Temp Limits (°C) -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 300/320 -60 to 300/320 -60 to 300/320 -60 to 300/320 7 in. Cage 121-5522 121-5523 121-5542 128-5512 128-5522 128-5552 122-5511 122-5512 122-5516 122-5513 122-5522 122-552a 122-552A 122-5532 122-5536 122-5533 122-5552 122-5561 122-5562 122-5563 123-5511 123-5512 123-5513 123-5526 123-5531 123-5532 123-5536 123-5533 123-5561 123-5562 123-5566 123-5563 125-5512 125-5537 125-553J 125-5532 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com 5 in. Cage 121-5522E 7890/6890 LTM Module 121-5522LTM 121-5523LTM 5975T LTM Toroid 221-5522LTM 128-5512LTM 128-5522LTM 122-5532E 122-5536E 122-5533E 122-5511LTM 122-5512LTM 122-5516LTM 122-5513LTM 122-5522LTM 122-552aLTM 122-552ALTM 122-5532LTM 122-5536LTM 122-5533LTM 122-5562E 123-5513E 123-5532E 123-5511LTM 123-5512LTM 123-5513LTM 123-5526LTM 123-5531LTM 123-5532LTM 123-5536LTM 123-5533LTM 125-5512LTM 125-5537LTM 125-553JLTM 125-5532LTM 222-5512LTM 222-5532LTM Low-bleed GC/MS Columns HP-5ms CH6H5 CH3 O Si CH3 O 95% Si CH6H5 Structure of HP-5ms 5% • (5%-Phenyl)-methylpolysiloxane • Identical selectivity to HP-5 • Non-polar • Very low bleed characteristics, ideal for GC/MS • Excellent inertness for active compounds including acidic and basic compounds • Improved signal-to-noise ratio for better sensitivity and mass spectral integrity • Bonded and cross-linked • Solvent rinsable • Equivalent to USP Phase G27 HP-5ms Chromatograms Environmental Chlorinated Pesticides, EPA Method 508 Nitrogen/Phosphorus Containing Pesticides, EPA Method 507 Organohalide Pesticides in Water, EPA Method 505 Semivolatile Compounds, EPA Method 8270 Page 578 Page 582 Page 578 Page 597 Food, Flavors and Fragrances Fragrance Allergens Page 618 Industrial Chemicals Trace Active Amines, 10 ng on-column Phenols I Page 645 Page 666 AGILENT J&W GC AND GC/MS COLUMNS 371 Low-bleed GC/MS Columns HP-5ms ID (mm) 0.18 0.20 0.25 Length (m) 20 12 25 50 15 30 60 0.32 25 30 60 372 GC AND GC/MS Film (µm) 0.18 0.33 0.33 0.33 0.10 0.25 1.00 0.10 0.25 0.50 1.00 0.10 0.25 0.52 0.10 0.25 0.50 1.00 0.25 Temp Limits (°C) -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 7 in. Cage 19091S-577 19091S-101 19091S-102 19091S-105 19091S-331 19091S-431 19091S-231 19091S-333 19091S-433 19091S-133 19091S-233 19091S-336 19091S-436 19091S-112 19091S-313 19091S-413 19091S-113 19091S-213 19091S-416 5 in. Cage 19091S-102E 19091S-433E 19091S-233E 19091S-436E 19091S-112E 19091S-413E www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com 7890/6890 LTM Module 19091S-577LTM 19091S-101LTM 19091S-102LTM 19091S-331LTM 19091S-431LTM 19091S-231LTM 19091S-333LTM 19091S-433LTM 19091S-133LTM 19091S-233LTM 19091S-112LTM 19091S-313LTM 19091S-413LTM 19091S-113LTM 19091S-213LTM 5975T LTM Toroid 29091S-433LTM Low-bleed GC/MS Columns O CH3 CH3 Si Si CH3 CH3 VF-5ms CH3 O m Structure of VF-5ms Si CH3 n • Excellent selectivity for aromatic compounds • Minimal column bleed improves sensitivity • Individual test certificates guarantee performance VF-5ms is a highly inert 5% phenyl-methyl column for increased sensitivity, accuracy and instrument uptime. The columns have the lowest guaranteed bleed specification of 1 pA @ 325°C (30 m, 0.25 mm, 0.25 µm). VF-5ms has a slightly higher polarity than VF-1ms, resulting in a better selectivity for aromatic compounds. This selectivity, combined with superior inertness, also makes these columns applicable for a wide range of semi-polar and even polar components, such as phenols. VF-5ms is also available with 0.15 mm ID for fast GC and GC/MS that can at least double sample throughput when compared to 0.25 and 0.32 mm ID columns. VF-5ms Chromatograms Environmental High resolution phenol analysis by GC/MS Page 602 Food, Flavors and Fragrances Pesticides in sunflower oil Page 640 VF-5ms ID (mm) 0.10 0.15 Length (m) 10 20 10 15 20 40 0.20 12 25 50 Film (µm) 0.40 0.40 0.15 0.15 0.15 0.30 0.60 0.15 0.60 0.33 0.33 0.33 Temp Limits (°C) -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 7 in. Cage CP8934 CP8933 CP9034 CP9035 CP9036 CP9037 CP9038 CP9039 CP9040 CP8935 CP8936 CP8937 5 in. Cage CP9034I5 CP9036I5 CP9039I5 CP8935I5 CP8936I5 (Continued) AGILENT J&W GC AND GC/MS COLUMNS 373 Low-bleed GC/MS Columns VF-5ms ID (mm) 0.25 Length (m) 15 25 30 50 60 0.32 15 25 30 50 60 0.53 15 30 374 GC AND GC/MS Film (µm) 0.10 0.25 0.50 1.00 0.25 0.40 0.10 0.25 0.50 1.00 0.25 0.10 0.25 1.00 0.10 0.25 1.00 0.52 0.10 0.25 0.50 1.00 0.25 0.40 0.25 1.00 0.50 1.00 1.50 0.50 1.00 1.50 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Temp Limits (°C) -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 310/335 7 in. Cage CP8938 CP8939 CP8963 CP8940 CP8941 CP8942 CP8943 CP8944 CP8945 CP8946 CP8947 CP8948 CP8960 CP8949 CP8950 CP8951 CP8952 CP8953 CP8954 CP8955 CP8956 CP8957 CP8958 CP8959 CP8961 CP8962 CP8971 CP8972 CP8973 CP8974 CP8975 CP8976 5 in. Cage CP8941I5 CP8943I5 CP8944I5 CP8948I5 CP8960I5 CP8954I5 CP8955I5 CP8957I5 CP8961I5 Low-bleed GC/MS Columns DB-XLB • EXceptionally Low Bleed • Low polarity • Extended temperature limit of 340/360°C • Unique selectivity • Excellent inertness for active compounds • Ideal for confirmational analyses • Excellent for pesticides, herbicides, PCBs and PAHs • Ideal for GC/MS • MSD testing and certification available • Bonded and cross-linked • Solvent rinsable Note: "DB-XLB is designed for inhibiting column bleed at high temperatures. It also appears to have inadvertently inherited an exceptional ability for separating many PCB congeners when used with MS detection. This stellar performance was maximized after careful optimization of the column dimensions, temperature programs, and carrier gas flow conditions." (Frame, G. Analytical Chemistry News & Features, Aug. 1, 1997, 468A-475A) DB-XLB Chromatograms Environmental Aroclors 1016-1268 (without 1221) CLP Pesticides CLP Pesticide Analysis Congeners in DIN Method PCBs EPA Method 552.2 Herbicides I PBDEs PCBs by EPA Method 8082 Pesticides, EPA 508.1 Phenols Phenoxy Acid Herbicides – Methyl Derivatives, EPA 8151A Page 592 Page 574 Page 573 Page 593 Page 603 Page 585 Page 592 Page 594 Page 577 Page 601 Page 584 Food, Flavors and Fragrances Ylang Ylang Oil Page 626 AGILENT J&W GC AND GC/MS COLUMNS 375 Low-bleed GC/MS Columns DB-XLB ID (mm) 0.18 0.20 0.25 0.32 0.53 376 GC AND GC/MS Length (m) Film (µm) 20 0.18 30 0.18 12 0.33 25 0.33 15 0.10 0.25 30 0.10 0.25 0.50 1.00 60 0.25 30 0.25 0.50 60 0.25 15 1.50 30 1.50 Temp Limits (°C) 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 320/340 30 to 320/340 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com 7 in. Cage 121-1222 121-1232 128-1212 128-1222 122-1211 122-1212 122-1231 122-1232 122-1236 122-1233 122-1262 123-1232 123-1236 123-1262 125-1212 125-1232 7890/6890 5 in. Cage LTM Module 121-1222E 121-1222LTM 121-1232LTM 128-1212E 128-1212LTM 128-1222LTM 122-1211LTM 122-1212LTM 122-1231LTM 122-1232LTM 122-1236LTM 122-1233LTM 122-1262E 123-1232LTM 123-1236LTM 125-1212LTM 125-1232LTM Low-bleed GC/MS Columns VF-Xms CH3 O Si CH3 CH3 Si CH3 CH3 O Si CH3 X Structure of VF-Xms Y • High arylene modified phase for accurate results • Isothermal applications up to 340°C for a broad application range • Ideal for confirmational analysis for ultimate confidence The VF-Xms has the lowest bleed of all FactorFour columns. VF-Xms delivers the ultimate in sensitivity and signal-to-noise ratio, and is the low bleed, more polar alternative to the VF-5ms. Compared to non-polar "ms" type phases, VF-Xms provides exceptionally high selectivity for pesticides and delivers high resolution in the shortest analysis time. The VF-Xms comes with an EZ-GRIP, simplifying installation, coupling and operation of capillary columns. For guaranteed performance, the retention index, efficiency, selectivity and bleed is measured and specified on the test report supplied with each column. VF-Xms Chromatograms Environmental Analysis of Polycyclic Aromatic Hydrocarbons Column shown with EZ-GRIP Page 570 VF-Xms ID (mm) 0.15 0.20 0.25 Length (m) 20 12 25 15 30 0.32 60 15 30 0.53 60 15 30 Film (µm) 0.15 0.33 0.33 0.10 0.25 0.10 0.25 0.50 1.00 0.25 0.25 1.00 0.10 0.25 0.50 1.00 0.25 1.50 1.50 Temp Limits (°C) 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 340/360 30 to 325/340 30 to 325/340 7 in. Cage CP9041 CP8800 CP8801 CP8802 CP8803 CP8805 CP8806 CP8807 CP8808 CP8809 CP8810 CP8811 CP8812 CP8813 CP8814 CP8815 CP8816 CP8817 CP8818 5 in. Cage CP8806I5 AGILENT J&W GC AND GC/MS COLUMNS 377 Low-bleed GC/MS Columns DB-35ms O CH3 CH3 Si Si CH3 CH3 CH3 O Si CH3 m Structure of DB-35ms n • Virtually equivalent to a (35%-Phenyl)-methylpolysiloxane • Mid-polarity • Very low bleed characteristics, ideal for GC/MS • Extended temperature limit of 340/360°C • Excellent inertness for active compounds • Ideal for confirmational analyses • Bonded and cross-linked • Solvent rinsable • Replaces HP-35ms • Close equivalent to USP Phase G42 DB-35ms Chromatograms 378 GC AND GC/MS Environmental CLP Pesticides EPA Method 552.2 Organochlorine Pesticides I EPA Method 8081A Organophosphorous Pesticides I, EPA Method 8141A PCBs by EPA Method 8082 Pesticides, EPA 508.1 Phenoxy Acid Herbicides – Methyl Derivatives, EPA 8151A Page 574 Page 603 Page 575 Page 583 Page 594 Page 577 Page 584 Industrial Chemicals Anilines Page 665 Life Sciences Barbiturates Benzodiazepines II Page 677 Page 677 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Low-bleed GC/MS Columns DB-35ms ID (mm) 0.18 0.20 0.25 0.32 0.53 Length (m) 20 15 25 15 30 60 15 30 30 Film (µm) 0.18 0.33 0.33 0.25 0.15 0.25 0.25 0.25 0.25 0.50 1.00 Temp Limits (°C) 50 to 340/360 50 to 340/360 50 to 340/360 50 to 340/360 50 to 340/360 50 to 340/360 50 to 340/360 50 to 340/360 50 to 340/360 50 to 320/340 50 to 320/340 7 in. Cage 121-3822 128-3812 128-3822 122-3812 122-3831 122-3832 122-3862 123-3812 123-3832 125-3837 125-3832 5 in. Cage 121-3822E 122-3832E 123-3832E 7890/6890 LTM Module 121-3822LTM 128-3812LTM 128-3822LTM 122-3812LTM 122-3831LTM 122-3832LTM 5975T LTM Toroid 221-3822LTM 222-3812LTM 222-3832LTM 123-3812LTM 123-3832LTM 125-3837LTM 125-3832LTM AGILENT J&W GC AND GC/MS COLUMNS 379 Low-bleed GC/MS Columns VF-35ms O Si CH3 O Si CH3 CH3 Si CH3 35% Structure of VF-35ms CH3 O Si CH3 X Y • Ideal for dual column confirmational analysis for ultimate confidence • High maximum temperature for broad applicability • Stabilized arylene-modified equivalent of a 35% phenylmethyl phase for longevity The VF-35ms is a medium polarity column, which is the ideal choice for trace environmental and chemical analyses, and as a confirmation column. The VF-35ms uses FactorFour technology to produce a low bleed, highly stable column with a programmable maximum temperature of 360°C. VF-35ms is also available with 0.15 mm ID for fast GC and GC/MS that can double sample throughput when compared to 0.25 and 0.32 mm ID columns. VF-35ms Chromatograms Environmental Organochlorine pesticides to EPA 625 via GC/MS Page 588 VF-35ms ID (mm) 0.15 0.20 0.25 0.32 0.53 380 GC AND GC/MS Length (m) 10 15 20 15 25 15 30 60 15 30 60 15 30 Film (µm) 0.15 0.15 0.15 0.33 0.33 0.25 0.10 0.15 0.25 0.50 1.00 0.25 0.25 0.25 0.50 1.00 0.25 1.00 0.50 1.00 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Temp Limits (°C) 40 to 340/360 40 to 340/360 40 to 340/360 40 to 340/360 40 to 340/360 40 to 340/360 40 to 340/360 40 to 340/360 40 to 340/360 40 to 340/360 40 to 340/360 40 to 340/360 40 to 340/360 40 to 340/360 40 to 340/360 40 to 340/360 40 to 340/360 40 to 325/350 40 to 325/350 40 to 325/350 7 in. Cage CP5887 CP5888 CP5889 CP8872 CP8873 CP8874 CP8875 CP8876 CP8877 CP8878 CP8879 CP8880 CP8881 CP8882 CP8883 CP8884 CP8885 CP8886 CP8887 CP8888 5 in. Cage CP8877I5 CP8878I5 CP8883I5 Low-bleed GC/MS Columns DB-17ms O CH 3 CH 3 Si Si CH 3 CH 3 CH 3 O m Structure of DB-17ms Si CH 3 n • Virtually equivalent to (50%-Phenyl)-methylpolysiloxane • 320/340°C upper temperature limit • Very low bleed mid-polarity column, ideal for GC/MS • Excellent inertness for active compounds • Enhanced mass spectral integrity • Bonded and cross-linked • Solvent rinsable • Best column for CLP pesticides DB-17ms Chromatograms Environmental PAHs Page 600 Life Sciences Hallucinogens Tocopherols Page 678 Page 678 DB-17ms ID (mm) 0.18 0.25 Length (m) 20 15 30 0.32 60 15 30 Film (µm) 0.18 0.15 0.25 0.15 0.25 0.25 0.25 0.25 Temp Limits (°C) 40 to 320/340 40 to 320/340 40 to 320/340 40 to 320/340 40 to 320/340 40 to 320/340 40 to 320/340 40 to 320/340 7 in. Cage 121-4722 122-4711 122-4712 122-4731 122-4732 122-4762 123-4712 123-4732 5 in. Cage 121-4722E 122-4732E 7890/6890 LTM Module 121-4722LTM 122-4711LTM 122-4712LTM 122-4731LTM 122-4732LTM 5975T LTM Toroid 221-4722LTM 222-4712LTM 222-4732LTM 123-4712LTM 123-4732LTM AGILENT J&W GC AND GC/MS COLUMNS 381 Low-bleed GC/MS Columns VF-17ms CH3 O Si O Si CH3 X Structure of VF-17ms Y • Deactivation technology improves data quality • Ideal EPA confirmation column for ultimate confidence • Bonded and cross-linked to allow solvent rinsing, reducing replacement costs VF-17ms is a 50% phenyl, 50% dimethylpolysiloxane, medium polarity, low bleed column for increased sensitivity, accuracy and instrument uptime. VF-17ms is often referenced in environmental and clinical methods. The use of new deactivation technology improves column stability, resulting in improved repeatability and column lifetimes. VF-17ms has a very low bleed specification at 2 pA @ 325°C (0.25 mm x 30 m x 0.25 µm). VF-17ms is also available with 0.15 mm ID for fast GC and GC/MS that can double sample throughput when compared to 0.25 and 0.32 mm ID columns. VF-17ms Chromatograms Environmental Organochlorine pesticides Page 582 VF-17ms ID (mm) 0.10 0.15 0.25 0.32 Length (m) 10 10 15 20 15 15 30 60 15 30 0.53 15 30 382 GC AND GC/MS Film (µm) 0.20 0.15 0.15 0.15 0.25 0.50 0.15 0.25 0.50 0.25 0.15 0.25 0.25 0.50 0.25 1.00 1.50 0.50 1.00 1.50 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Temp Limits (°C) 40 to 330/360 40 to 330/360 40 to 330/360 40 to 330/360 40 to 330/360 40 to 330/360 40 to 330/360 40 to 330/360 40 to 330/360 40 to 330/360 40 to 330/360 40 to 330/360 40 to 330/360 40 to 330/360 40 to 330/360 40 to 330/360 40 to 310/340 40 to 330/360 40 to 310/340 40 to 310/340 7 in. Cage CP8977 CP5882 CP5883 CP5884 CP8979 CP8980 CP8981 CP8982 CP8983 CP8984 CP8986 CP8987 CP8990 CP8991 CP8994 CP8996 CP8998 CP9000 CP9001 CP9002 5 in. Cage CP8982I5 CP8990I5 Low-bleed GC/MS Columns C N (CH2)3 O Si (CH2)3 C N VF-23ms CH3 O Si CH3 CH3 Si CH3 Y X Structure of VF-23ms • 100% bonded phase permits column rinsing to enhance column lifetime • Fast run times improve productivity • Operating temperature up to 260°C expands the application range The VF-23ms column has a high polarity and highly substituted cyanopropyl low bleed phase. VF-23ms features a unique combination of high polarity and low bleed to enable more accurate analysis of very polar analytes. The enhanced stabilization of the VF-23ms permits splitless injection, column rinsing and temperatures up to 260°C to be used. Compared to other 23ms type phases, this expands the range of possible applications by enabling the analysis of higher molecular weight compounds. VF-23ms is also available with 0.15 mm ID for fast GC and GC/MS that can double sample throughput when compared to 0.25 and 0.32 mm ID columns. VF-23ms Chromatograms Food, Flavors and Fragrances Fast screening of FAME isomers in butter Page 639 VF-23ms ID (mm) 0.10 0.15 0.25 Length (m) 10 15 20 40 15 30 60 0.32 15 30 60 0.53 15 30 Film (µm) 0.10 0.15 0.15 0.15 0.25 0.15 0.25 0.15 0.25 0.25 0.15 0.25 0.15 0.25 0.50 0.50 Temp Limits (°C) 40 to 260/260 40 to 260/260 40 to 260/260 40 to 260/260 40 to 260/260 40 to 260/260 40 to 260/260 40 to 260/260 40 to 260/260 40 to 260/260 40 to 260/260 40 to 260/260 40 to 260/260 40 to 260/260 40 to 245/245 40 to 245/245 7 in. Cage CP8819 CP5886 CP9042 CP5885 CP8820 CP8821 CP8822 CP8823 CP8824 CP8825 CP8826 CP8827 CP8828 CP8829 CP8830 CP8831 5 in. Cage CP8820I5 CP8821I5 CP8822I5 CP8824I5 AGILENT J&W GC AND GC/MS COLUMNS 383 Low-bleed GC/MS Columns VF-200ms CF3 CH2 CH2 CH3 O Si CH3 O Si CH3 • Superior deactivation delivers symmetrical peaks to improve data accuracy • Ultra-low background noise for trace analysis maximizes sensitivity • Ideal for sensitive and selective detector systems for enhanced productivity X Y Structure of VF-200ms The VF-200ms is designed with a unique selectivity for compounds rich in dipole-dipole interactions, resulting from the electrophilic nature of the trifluoropropyl stationary phase. VF-200ms is especially suited for electron rich, high dipole moment compounds like ketones, aldehydes, nitro- or chloro-containing compounds, PAHs, unsaturated compounds, silanes and CFCs. VF-200ms, as with all FactorFour columns, offers superior surface deactivation and thereby symmetrical peak shapes. The high inertness of the VF-200ms leads to more accurate peak identification and reliable analysis. The VF-200ms trifluoropropyl phase has very high temperature stability and can be used routinely up to 350°C. VF-200ms is also available with 0.15 mm ID for fast GC and GC/MS that can double sample throughput when compared to 0.25 and 0.32 mm ID columns. VF-200ms Chromatograms Industrial Chemicals Fast separation of silanes Page 670 VF-200ms ID (mm) 0.15 Length (m) 10 20 0.25 15 30 0.32 0.53 384 GC AND GC/MS 60 15 30 15 30 Film (µm) 0.15 0.15 0.60 0.25 0.50 0.10 0.25 0.50 1.00 0.25 0.25 0.25 0.50 1.00 1.00 0.50 1.00 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Temp Limits (°C) 0 to 325/350 0 to 325/350 0 to 325/350 0 to 325/350 0 to 325/350 0 to 325/350 0 to 325/350 0 to 325/350 0 to 325/350 0 to 325/350 0 to 325/350 0 to 325/350 0 to 325/350 0 to 325/350 0 to 300/325 0 to 300/325 0 to 300/325 7 in. Cage CP5893 CP5891 CP5892 CP8855 CP8856 CP8857 CP8858 CP8859 CP8860 CP8861 CP8862 CP8863 CP8864 CP8865 CP8866 CP8867 CP8868 5 in. Cage CP8855I5 CP8859I5 CP8860I5 CP8865I5 CP8868I5 Low-bleed GC/MS Columns DB-225ms • Virtually equivalent to (50%-Cyanopropylphenyl)-methylpolysiloxane • Mid/high polarity • Excellent for separations of cis- and trans-fatty acid methyl esters (FAMEs) • Low bleed • Bonded and cross-linked • Solvent rinsable • Close equivalent to USP Phase G7 DB-225ms Chromatograms Environmental Tetrachlorodibenzo-p-furans Page 591 Food, Flavors and Fragrances FAMEs II Page 633 DB-225ms ID (mm) 0.25 0.32 Length (m) 15 30 60 30 Film (µm) 0.25 0.25 0.25 0.25 Temp Limits (°C) 40 to 240 40 to 240 40 to 240 40 to 240 7 in. Cage 122-2912 122-2932 122-2962 123-2932 5 in. Cage 122-2932E 7890/6890 LTM Module 122-2912LTM 122-2932LTM 5975T LTM Toroid 222-2912LTM 222-2932LTM 123-2932LTM AGILENT J&W GC AND GC/MS COLUMNS 385 Low-bleed GC/MS Columns VF-WAXms O CH2 CH2 OH n Structure of VF-WAXms • Specially designed for MS for more accurate results with polar compounds • Operating temperature range of 20°C to 250°C for maximum flexibility • Better signal-to-noise ratio for trace analyses improves productivity The VF-WAXms is a high performance column for applications in the food, flavors and fragrances markets, and especially where trace analyses are required. These applications often require higher temperatures to analyze polar compounds, and therefore need an ultra-stable wax as a stationary phase. The very low bleed of VF-WAXms provides increased sensitivity, extended column lifetime and greater accuracy, even at higher temperatures. Advanced coating technology means that VF-WAXms columns are highly inert. Such inertness gives better chromatograms, enhancing critical pair separation. With the introduction of the VF-WAXms column, wax applications such as food, flavors and fragrances can now benefit from the use of GC/MS detectors. Impurities can easily be identified using an MS detector when a wax column is required for separation. Significantly improved performance is achieved with VF-WAXms columns, yet the typical selectivity of PEG is unchanged. VF-WAXms is also available with 0.15 mm ID for fast GC and GC/MS that can double sample throughput when compared to 0.25 and 0.32 mm ID columns. VF-WAXms Chromatograms Food, Flavors and Fragrances Acids 386 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Page 631 Low-bleed GC/MS Columns Tips & Tools As a special MS-type phase, the VF-WAXms column generates less bleed, and therefore less noise and higher signal-to-noise ratios for critical components. VF-WAXms ID (mm) 0.10 0.15 0.25 Length (m) 10 20 10 15 20 30 15 25 30 60 0.32 15 30 60 0.53 15 30 60 Film (µm) 0.10 0.20 0.10 0.15 0.15 0.15 0.15 0.25 0.50 0.20 0.25 0.50 1.00 0.25 0.50 0.25 0.50 1.00 0.25 0.50 1.00 0.25 0.50 1.00 1.00 2.00 1.00 2.00 1.00 2.00 Temp Limits (°C) 20 to 250/260 20 to 250/260 20 to 250/260 20 to 250/260 20 to 250/260 20 to 250/260 20 to 250/260 20 to 250/260 20 to 250/260 20 to 250/260 20 to 250/260 20 to 250/260 20 to 240 20 to 250/260 20 to 240 20 to 250/260 20 to 250/260 20 to 250/260 20 to 250/260 20 to 250/260 20 to 240 20 to 250/260 20 to 240 20 to 230 20 to 250/260 20 to 240 20 to 240 20 to 230 20 to 230 20 to 220 7 in. Cage CP9219 CP9218 CP9229 CP9200 CP9201 CP9220 CP9202 CP9203 CP9221 CP9204 CP9205 CP9222 CP9206 CP9207 CP9223 CP9209 CP9224 CP9208 CP9212 CP9210 CP9211 CP9214 CP9225 CP9213 CP9226 CP9227 CP9215 CP9216 CP9228 CP9217 5 in. Cage CP9229I5 CP9205I5 CP9212I5 CP9225I5 CP9226I5 AGILENT J&W GC AND GC/MS COLUMNS 387 Low-bleed GC/MS Columns VF-624ms and VF-1301ms C N (CH2)3 O Si CH3 X CH3 O Si CH3 CH3 O Si CH3 CH3 Si CH3 Y Z Structure of VF-624ms and VF-1301ms • Improved signal-to-noise ratio for more accurate trace analysis • Eliminate ghost peaks and unstable baselines for best data accuracy • Enhanced selectivity eliminating co-eluters such as benzene and 1,2-dichloroethane for improved productivity The VF-624ms and VF-1301ms are the world's first ultra-low bleed 6% cyanopropyl/phenyl, 94% PDMS GC columns. VF-624ms columns set a new standard for the analysis of volatile organic compounds. Improved phase technology reduces bleed, thereby increasing signal-tonoise ratios. These columns are especially suited for analyzing solvents according to EPA Methods 524, 624 and 8260, as well as USP 467. The ultra low bleed, thin filmed, VF-1301ms column has a similar selectivity and is suitable for semi-volatile organic solvents, as well as PCBs and pesticides. VF-624ms and VF-1301ms are also available with 0.15 mm ID for fast GC and GC/MS that can boost sample throughput when compared to 0.25 and 0.32 mm ID columns. VF-624ms and VF-1301ms Chromatograms Environmental FactorFour cyano columns eliminate unstable baselines Page 610 VF-624ms ID (mm) 0.15 0.25 0.32 0.53 388 GC AND GC/MS Length (m) 15 20 30 40 30 60 30 60 30 60 75 Film (µm) 0.84 0.84 0.84 0.84 1.40 1.40 1.80 1.80 3.00 3.00 3.00 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Temp Limits (°C) -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 265/280 -40 to 265/280 7 in. Cage CP9101 CP9100 CP9109 CP9110 CP9102 CP9103 CP9104 CP9105 CP9106 CP9107 CP9108 5 in. Cage CP9101I5 CP9102I5 CP9103I5 CP9104I5 CP9105I5 CP9106I5 Low-bleed GC/MS Columns VF-1301ms ID (mm) 0.10 0.15 0.25 Length (m) 10 15 20 15 30 60 0.32 15 30 0.53 60 15 30 Film (µm) 1.00 0.15 0.15 1.00 0.25 1.00 0.25 1.00 0.25 1.00 0.25 1.00 1.00 1.00 1.00 1.50 Temp Limits (°C) -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 -40 to 280/300 7 in. Cage CP9066 CP9050 CP9051 CP9052 CP9053 CP9054 CP9055 CP9056 CP9057 CP9058 CP9059 CP9060 CP9061 CP9062 CP9063 CP9064 5 in. Cage CP9060I5 AGILENT J&W GC AND GC/MS COLUMNS 389 Low-bleed GC/MS Columns VF-1701ms C N (CH2)3 O Si CH3 X CH3 O Si CH3 CH3 O Si CH3 CH3 Si CH3 Y Z Structure of VF-1701ms • Highly inert for difficult analytes such as p,p’-DDT to improve productivity • Column deactivation for more accurate trace analysis • Eliminate ghost peaks and unstable baselines for more reliable data The VF-1701ms is the world’s first ultra-low bleed 14% cyanopropyl/phenyl, 86% PDMS GC column for pesticides, PCBs and semi-volatile organic compounds. Improved phase technology delivers increased inertness and reduced bleed, resulting in more accurate trace analysis. The bleed specification is 2 pA @ 280°C for a 0.25 mm x 60 m x 0.25 µm ID column. VF-1701ms is also available with 0.15 mm ID for fast GC and GC/MS that can double sample throughput when compared to 0.25 and 0.32 mm ID columns. VF-1701ms Chromatograms Environmental Analysis of pesticides using EPA 8081 with ECD 390 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Page 576 Low-bleed GC/MS Columns VF-1701ms ID (mm) 0.10 Length (m) 10 0.15 20 15 20 0.25 15 30 60 0.32 15 30 60 0.53 15 30 60 Film (µm) 0.20 0.40 0.10 0.10 0.15 0.60 0.15 0.60 0.15 0.25 1.00 0.15 0.25 1.00 0.15 0.25 0.50 1.00 0.15 0.25 1.00 0.10 0.15 0.25 1.00 0.15 0.25 1.00 1.00 0.10 0.25 0.50 1.00 1.50 1.00 1.50 Temp Limits (°C) -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 280/300 -20 to 265/280 7 in. Cage CP9140 CP9141 CP9142 CP9175 CP9143 CP9144 CP9145 CP9146 CP9147 CP9148 CP9149 CP9150 CP9151 CP9152 CP9153 CP9154 CP9155 CP9156 CP9157 CP9158 CP9159 CP9160 CP9161 CP9162 CP9163 CP9164 CP9165 CP9166 CP9167 CP9168 CP9169 CP9170 CP9171 CP9172 CP9173 CP9174 5 in. Cage CP9149I5 CP9151I5 CP9152I5 CP9154I5 CP9155I5 CP9166I5 AGILENT J&W GC AND GC/MS COLUMNS 391 Polysiloxane Polymers Columns Polysiloxane Polymers Columns Polysiloxanes are the most common stationary phases. They are available in the greatest variety and are stable, robust and versatile. Standard polysiloxanes are characterized by the repeating siloxane backbone. Each silicon atom contains two functional groups. The type and amount of the groups distinguish each stationary phase and its properties. With the merger of Agilent and J&W Scientific there were many similar columns with the same type of polymer. In some cases the manufacturing and QC processes were exactly the same. In these cases the DB version was kept. In the cases where the HP and the DB columns had any manufacturing or QC differences, we opted to keep both phases available, as in the case of DB-1 and HP-1. Each of these columns is a high-quality product made to meet exacting quality control testing. However, there may be some subtle performance differences. For example the DB-35 and the HP-35 have slightly different selectivities. Therefore, we are still offering both DB and HP versions for our customers who have methods already developed on these columns. DB-1 CH3 O Si CH3 100% Structure of DB-1 392 GC AND GC/MS • 100% Dimethylpolysiloxane • Non-polar • Excellent general purpose column • Wide range of applications • Low bleed • High temperature limit • Bonded and cross-linked • Solvent rinsable • Wide range of column dimensions available • Equivalent to USP Phase G2 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Polysiloxane Polymers Columns DB-1 Chromatograms Environmental EPA Air Analysis Compendium Method TO-14 Standard EPA Method 551 Pyrethrins Page 611 Page 609 Page 595 Food, Flavors and Fragrances Fragrance Reference Standard I Spearmint Oil Page 620 Page 617 Industrial Chemicals Aldehydes and Ketones Aromatics in Finished Gasoline – ASTM Method 5769 Esters I PFBHA Derivative Glycols III Halogenated Hydrocarbons II Nitrogen Based Solvents I Triethylene Glycol and Impurities Volatile Amines Page 648 Page 702 Page 653 Page 649 Page 656 Page 658 Page 662 Page 656 Page 645 Life Sciences Anabolic Steroids Anticonvulsants Page 681 Page 675 Petroleum Aromatics in Finished Gasoline – ASTM Method 5769 DNPH Derivative Polyethylene Regular Unleaded Gasoline (California Phase 1) – "Normal" GC Run II Volatile Sulfur Compounds Page 702 Page 649 Page 706 Page 704 Page 694 AGILENT J&W GC AND GC/MS COLUMNS 393 Polysiloxane Polymers Columns DB-1 ID (mm) 0.05 0.10 0.15 0.18 0.20 0.25 Length (m) Film (µm) 10 0.05 0.05 0.20 5 0.12 10 0.10 0.40 20 0.10 0.40 40 0.20 0.40 10 1.20 10 0.18 0.20 0.40 20 0.18 0.40 40 0.40 12 0.33 25 0.33 30 0.8 50 0.33 15 0.10 0.25 1.00 25 0.25 30 0.10 0.25 0.50 1.00 50 0.25 60 0.10 0.25 0.50 1.00 100 0.50 150 1.00 Temp Limits (°C) -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 7 in. Cage 126-1012 126-10SP 126-1013 127-100a 127-100A 127-1013 127-101A 127-1023 127-1046 127-1043 12A-1015 121-1012 121-101A 121-1013 121-1022 121-1023 121-1043 128-1012 128-1022 128-1034 128-1052 122-1011 122-1012 122-1013 122-1022 122-1031 122-1032 122-103E 122-1033 122-1052 122-1061 122-1062 122-106E 122-1063 122-10AE 122-10G3 5 in. Cage 127-1012E 127-1013E 127-1022E 127-1023E 127-1046E 7890/6890 LTM Module 126-1012LTM 126-1013LTM 127-100aLTM 127-100ALTM 127-1013LTM 127-1022LTM 127-1023LTM 12a-1015LTM 121-1012E 12A-1015LTM 121-101aLTM 121-1013E 121-1013LTM 121-1022E 121-101ALTM 121-1023LTM 121-1043E 128-1012LTM 128-1022LTM 128-1034LTM 122-1011LTM 122-1012LTM 122-1013LTM 122-1022LTM 122-1031LTM 122-1032E 122-1032LTM* 122-103ELTM 122-1033E 122-1033LTM *Also available as LTM column toroid assembly for Agilent 5975T, 0.25 mm x 30 m, 0.25 µm, P/N 222-1032LTM (Continued) 394 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Polysiloxane Polymers Columns DB-1 ID (mm) 0.32 Length (m) Film (µm) 10 0.5 15 0.10 0.25 1.00 3.00 5.00 25 0.12 0.25 0.52 1.05 30 0.10 0.25 0.50 1.00 1.50 3.00 5.00 50 0.25 0.52 1.05 1.20 5.00 60 0.10 0.25 0.50 1.00 1.50 2.00 3.00 5.00 Temp Limits (°C) -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 280/300 -60 to 280/300 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 300/320 -60 to 280/300 -60 to 280/300 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 280/300 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 300/320 -60 to 280/300 -60 to 280/300 -60 to 280/300 7 in. Cage 123-100E 123-1011 123-1012 123-1013 123-1014 123-1015 123-1027 123-1022 123-1026 123-102F 123-1031 123-1032 123-103E 123-1033 123-103B 123-1034 123-1035 123-1052 123-1056 123-105F 123-105C 123-1055 123-1061 123-1062 123-106E 123-1063 123-106B 123-106G 123-1064 123-1065 5 in. Cage 7890/6890 LTM Module 123-100ELTM 123-1011LTM 123-1012LTM 123-1013LTM 123-1014LTM 123-1015LTM 123-1027LTM 123-1022LTM 123-1026LTM 123-102FLTM 123-1031LTM 123-1032LTM 123-103ELTM 123-1033E 123-1033LTM 123-103BLTM 123-1034LTM 123-1035LTM 123-1062E 123-1063E 123-106BE 123-1064E 123-1065E (Continued) AGILENT J&W GC AND GC/MS COLUMNS 395 Polysiloxane Polymers Columns DB-1 ID (mm) 0.45 0.53 396 GC AND GC/MS Length (m) Film (µm) 30 1.27 2.55 5 0.88 2.65 5.00 7.5 1.50 10 2.65 5.00 15 0.15 0.25 0.50 1.00 1.50 3.00 5.00 25 1.00 5.00 30 0.10 0.25 0.50 1.00 1.50 2.65 3.00 5.00 50 5.00 60 1.00 1.50 3.00 5.00 105 5.00 Temp Limits (°C) -60 to 325/350 -60 to 260/280 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 260/280 -60 to 260/280 -60 to 340/360 -60 to 320/340 -60 to 300/320 -60 to 300/320 -60 to 300/320 -60 to 260/280 -60 to 260/280 -60 to 300/320 -60 to 260/280 -60 to 340/360 -60 to 320/340 -60 to 300/320 -60 to 300/320 -60 to 300/320 -60 to 260/280 -60 to 260/280 -60 to 260/280 -60 to 260/280 -60 to 300/320 -60 to 300/320 -60 to 260/280 -60 to 260/280 -60 to 260/280 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com 7 in. Cage 124-1032 124-1034 125-100a 125-100A 125-1005 125-1002 125-10HB 125-10H5 125-1011 125-101K 125-1017 125-101J 125-1012 125-1014 125-1015 125-102J 125-1025 125-1039 125-103K 125-1037 125-103J 125-1032 125-103B 125-1034 125-1035 125-1055 125-106J 125-1062 125-1064 125-1065 125-10B5 5 in. Cage 125-10HBE 125-1011E 125-1012E 125-103KE 125-1034E 125-1035E 125-106JE 125-1062E 125-1065E 7890/6890 LTM Module 124-1032LTM 124-1034LTM 125-100aLTM 125-100ALTM 125-1005LTM 125-1002LTM 125-10HBLTM 125-10H5LTM 125-1011LTM 125-101KLTM 125-1017LTM 125-101JLTM 125-1012LTM 125-1014LTM 125-1015LTM 125-102JLTM 125-1025LTM 125-1039LTM 125-103KLTM 125-1037LTM 125-103JLTM 125-1032LTM 125-103BLTM 125-1034LTM 125-1035LTM Polysiloxane Polymers Columns HP-1 CH3 O Si CH3 100% Structure of HP-1 • 100% Dimethylpolysiloxane • Non-polar • Excellent general purpose column – "Industry Standard" • Wide range of applications • Superior performance for low molecular weight alcohols (40°C reduces operating costs • Temperature stability up to 300°C allows short regeneration times and improves efficiency • One injector, one detector simplifies operation Select Permanent Gases/CO2 is a set of two parallel columns that combine CP-Molsieve 5Å for permanent gas analysis and CP-PoraBOND Q for CO2 analysis. The selection of column dimensions accords with your need for fast separation, lowest level analysis, and quantification of argon/oxygen. The Select Permanent Gases column separates permanent gases and CO2 in a single run, and columns are coupled, tested, and securely mounted on the EZ-GRIP column mounting system. The CP7429 Select Permanent Gases/CO2 column is designed for fast analysis of permanent gases and CO2. For resolution of the difficult-to-separate argon/oxygen and helium/neon pairs, use CP7430 Select Permanent Gases/HR (High Resolution) column. Select Permanent Gases Chromatograms Environmental Fast analysis of permanent gases and CO2 Page 616 Select Permanent Gases ID (mm) Select Permanent Gases/CO2 Select Permanent Gases/HR Temp Limits (°C) 300/325 300/325 7 in. Cage CP7429 CP7430 AGILENT J&W GC AND GC/MS COLUMNS 499 Petroleum Columns CP-Volamine • Excellent stability for samples containing water expands the application range • Maximum temperature of 265°C for enhanced productivity • Highly inert providing sharp amine peaks for accurate results CP-Volamine is optimized for the separation of volatile amines. The column is coated with a nonpolar stationary phase and produces symmetrical peaks due to MPD (Multi-Purpose Deactivation) technology. CP-Volamine is the most stable column for analyzing volatile amines even when the sample contains high percentages of water. The CP-Volamine column is the best choice for analyzing volatile amines like MMA, DMA and TMA (monomethyl, dimethyl and trimethyl amine). On this column other components of interest such as alcohols, water, and ammonia also elute as sharp peaks. CP-Volamine is highly inert, elutes a wide range of compounds, and delivers excellent performance and unique stability for water. Both 15 m and 30 m columns are available to ensure the shortest run times for amine samples that do not require the resolution of the 60 m column. CP-Volamine Chromatograms Industrial Chemicals Amines and alcohols Page 643 CP-Volamine ID (mm) 0.32 Length (m) 15 30 60 Temp Limits (°C) 265/300 265/300 265/275 Tips & Tools For fast and easy GC pressure and flow calculations at your fingertips with Agilent's GC Calculator Application, visit www.agilent.com/chem/GCapp 500 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com 7 in. Cage CP7446 CP7447 CP7448 5 in. Cage CP7447I5 CP7448I5 Petroleum Columns CP-Sil 8 CB for Amines • Good inertness towards basic compounds for best accuracy • Guaranteed for the analysis of a broad range of amines for reliable results • Available in non-polar and polar phases for broad application range CP-Sil 8 CB for Amines is a base-deactivated 5% phenyl polydimethylsiloxane column that can be used for a wide range of amines. Due to a thermal stability up to 350°C, it analyzes a broad range of amines up to C20, as well as alkanolamines. CP-Sil 8 CB for Amines Chromatograms Industrial Chemicals Analysis of ethanolamines Page 643 CP-Sil 8 CB for Amines ID (mm) 0.15 0.25 0.32 0.53 Length (m) 25 30 30 30 30 Film (µm) 2.00 0.25 0.50 1.00 1.00 Temp Limits (°C) 325/350 325/350 325/350 325/350 325/350 7 in. Cage CP7599 CP7598 CP7595 CP7596 CP7597 5 in. Cage Temp Limits (°C) 220/220 220/220 7 in. Cage CP7422 CP7424 5 in. Cage CP7422I5 Temp Limits (°C) 60 to 260/275 7 in. Cage CP7405 5 in. Cage CP7405I5 CP7598I5 CP7595I5 CP7596I5 CP7597I5 CP-Wax for Volatile Amines and Diamines CP-Wax for Volatile Amines and Diamines ID (mm) 0.32 0.53 Length (m) 25 25 Film (µm) 1.20 2.00 CP-Wax 51 for Amines CP-Wax 51 for Amines ID (mm) 0.25 Length (m) 25 Film (µm) 0.20 AGILENT J&W GC AND GC/MS COLUMNS 501 Petroleum Columns CP-Lowox • Unique selectivity for a wide range of oxygenates maximizes flexibility • No particle loss preserves detector performance • Suitable for process applications CP-Lowox offers a unique solution to the chemical and petrochemical industries. It is now possible to analyze trace level oxygenate impurities in gas and liquid hydrocarbon streams. This high polarity makes the column ideal for the measurement of oxygenated compounds. CP-Lowox can be used for the prevention of catalyst contamination by oxygenates, process/on-line applications or portable GC applications (ASTM D 7059). CP-Lowox Chromatograms Petroleum Analysis of oxygenates in a C1 to C5 hydrocarbon mix Page 707 CP-Lowox ID (mm) 0.53 Length (m) 10 Film (µm) 10.00 Temp Limits (°C) 0 to 350/350 7 in. Cage CP8587 5 in. Cage CP8587I5 GS-OxyPLOT • Accurate analysis of ppm/ppb level oxygenates in C1 to C10 hydrocarbons • Strong selectivity for a wide range of oxygenates (ethers, alcohols, aldehydes, and ketones) in complex matrices such as gaseous hydrocarbons, motor fuels, and crude oil • Suitable for ASTM methods for oxygenates • Very high column stability (upper temperature limit of 350°C) with no column bleed • Stable phase coating virtually eliminates particle generation and detector spiking • Excellent for low concentration, quantitative GC analysis • Ideal for selective heart-cutting applications GS-OxyPLOT Chromatograms Petroleum Selected Oxygenates Trace Oxygenates in Light Hydrocarbon Matrices Page 686 Page 686 GS-OxyPLOT ID (mm) 0.53 502 GC AND GC/MS Length (m) 10 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Temp Limits (°C) 350 7 in. Cage 115-4912 5 in. Cage 115-4912E Petroleum Columns CP-Sil 5 CB for Formaldehyde CP-Sil 5 CB for Formaldehyde ID (mm) 0.32 Length (m) 60 Film (µm) 8.00 Temp Limits (°C) -60 to 300/325 7 in. Cage CP7475 5 in. Cage CP7475I5 Film (µm) 0.20 Temp Limits (°C) -15 to 90/95 7 in. Cage CP7520 5 in. Cage CP7520I5 Temp Limits (°C) -60 to 300/325 7 in. Cage CP7475 CP-Squalane CP-Squalane ID (mm) 0.25 Length (m) 100 CP-Propox CP-Propox ID (mm) 0.32 Length (m) 60 Film (µm) 8.00 Tips & Tools View up-to-date educational resources such as posters, Application Notes, training tools, seminars, product information and more at www.agilent.com/chem/mygccolumns AGILENT J&W GC AND GC/MS COLUMNS 503 Semivolatiles Columns Semivolatiles Columns Recommended Columns for Semivolatiles • HP-5ms, DB-5.625, DB-5ms Ultra Inert, HP-5ms Ultra Inert for EPA methods 8270 and 525 • DB-XLB for PCB congeners • HP-5ms, DB-5ms Ultra Inert, HP-5ms Ultra Inert or DB-35ms for PAHs • DB-5ms, DB-5ms Ultra Inert or DB-XLB for phenols Semivolatiles are usually extracted from soil samples or other environmental matrices. GC columns with precise retention time reproducibility and good mass spectrometer performance are key enablers for these often demanding analyses. DB-Dioxin • Specifically engineered for the analysis of polychlorinated dibenzodioxins (PCDDs) and dibenzofurans (PCDFs) • Resolves 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in one run • Low bleed • Bonded and cross-linked • Solvent rinsable Note: 100 psi regulator required to reach optimum carrier gas velocity DB-Dioxin 504 GC AND GC/MS ID (mm) 0.25 Length (m) 60 0.32 60 Film (µm) 0.15 0.25 0.15 0.25 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Temp Limits (°C) 40 to 250/270 40 to 250/270 40 to 250/270 40 to 250/270 7 in. Cage 122-2461 122-2462 123-2461 123-2462 5 in. Cage 122-2461E Semivolatiles Columns CP-Sil 88 for Dioxins • Integrated retention gap eliminates leaks and extends column lifetime • 2,3,7,8-TCDD can be determined at low concentrations for ease-of-use • Guaranteed analysis of dioxin isomers for complete confidence in results The CP-Sil 88 column has a very high polarity and a specific selectivity for dioxins and dibenzofuran separations. The column is supplied with an integrated retention gap to avoid problems with solvent condensation, thus allowing repeated splitless injections without phase deterioration, extending column life. In addition, because of the integrated retention gap, data quality is considerably improved. For the shortest analysis times, a series of thin-film coated columns is available that allow applications up to 270°C in temperature programmed mode. CP-Sil 88 for Dioxins Chromatograms Environmental Dioxins and dibenzofurans Page 571 CP-Sil 88 for Dioxins ID (mm) 0.25 0.32 Length (m) 30 50 60 60 Film (µm) 0.10 0.20 0.10 0.13 Temp Limits (°C) 50 to 250/270 50 to 225/240 50 to 250/270 50 to 250/270 7 in. Cage CP7497 CP7588 CP7498 CP7499 AGILENT J&W GC AND GC/MS COLUMNS 505 Semivolatiles Columns DB-5.625 • Close equivalent to a (5%-Phenyl)-methylpolysiloxane • Non-polar • Specially processed to exhibit excellent inertness for EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols* • Surpasses EPA performance criteria for semivolatiles • Inert for base, neutral and acidic compounds • High temperature limit with excellent thermal stability and low bleed • Bonded and cross-linked • Solvent rinsable *Pentachlorophenol, 2,4-dinitrophenol, carbazole, and N-nitrosodiphenylamine used to test response factors. DB-5.625 Chromatograms Environmental Analysis of Semivolatiles European Red List Volatiles Page 591 Page 609 DB-5.625 506 GC AND GC/MS ID (mm) 0.18 Length (m) 20 0.25 30 0.32 60 30 Film (µm) 0.18 0.36 0.25 0.50 1.00 0.25 0.25 0.50 Temp Limits (°C) -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 -60 to 325/350 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com 7 in. Cage 121-5621 121-5622 122-5631 122-5632 122-5633 122-5661 123-5631 123-5632 7890/6890 LTM Module 121-5621LTM 121-5622LTM 122-5631LTM 122-5632LTM 122-5633LTM 123-5631LTM 123-5632LTM Semivolatiles Columns HP-5ms Semivolatile • (5%-Phenyl)-methylpolysiloxane, identical selectivity to HP-5 • Non-polar • Very low bleed characteristics, ideal for GC/MS • Specifically tested for inertness for active compounds including acidic and basic compounds • Improved signal-to-noise ratio for better sensitivity and mass spectral integrity • Bonded and cross-linked • Solvent rinsable • Equivalent to USP Phase G27 HP-5ms Semivolatile ID (mm) 0.25 Length (m) Film (µm) 30 0.50 Temp Limits (°C) -60 to 325/350 7 in. Cage 19091S-139 7890/6890 LTM Module 19091S-139LTM CP-Sil 5/C18 CB for PCB • Guaranteed for very high resolution PCB analysis for ultimate confidence • 100 m column separates critical isomer pairs for accurate results • Use with high sensitivity ECD detection for enhanced productivity CP-Sil 5/C18 CB for PCB has a lower polarity than 100% polydimethylsiloxane due to its C18 substitutions. Due to the absence of cyano groups it provides high signal-to-noise ratios for ECD detectors. The 100 m column separates critical isomer pairs: 28/31, 56/60, 149/118, 105/153/132 and 170/190. CP-Sil 5/C18 CB for PCB ID (mm) 0.25 0.32 Length (m) 50 100 100 Film (µm) 0.10 0.10 0.10 Temp Limits (°C) 275/300 275/300 275/300 7 in. Cage CP7477 CP7476 CP7478 AGILENT J&W GC AND GC/MS COLUMNS 507 Semivolatiles Columns CP-Sil 8 CB for PCB • Guaranteed for the analysis of PCBs according to DIN Method 51527 for confidence in results • Suitable for high sensitivity ECD detection for low detection limits • High temperature stability provides extended lifetime and enhanced productivity CP-Sil 8 CB has high temperature stability and is resistant to continuous splitless injections. Due to the absence of cyano groups the column provides high signal-to-noise ratios on ECD. CP-Sil 8 CB for PCB ID (mm) 0.25 Length (m) 50 Film (µm) 0.25 Temp Limits (°C) 300/325 7 in. Cage CP7482 Film (µm) 0.25 Temp Limits (°C) 300/325 7 in. Cage CP7482 Select 28/31 Select 28/31 ID (mm) 0.25 508 GC AND GC/MS Length (m) 50 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Volatiles Columns Volatiles Columns Recommended Columns for Volatiles • DB-VRX and DB-624 for EPA Methods 502.2 and 8021 • DB-VRX (60 m, 0.25 mm ID) for GC/MS volatiles methods • DB-VRX (20 m, 0.18 mm ID) for fast GC/MS volatiles analysis using a 5973 MSD (Not recommended for Ion Trap MS or older MSDs) • DB-MTBE for extended EPA Method 8020 • DB-TPH for the analysis of BTEX and gasoline total petroleum hydrocarbons • DB-624 (20 m, 0.18 mm ID) for fast GC/MS volatiles analysis Agilent offers a selection of advanced polymer chemistries for increasingly demanding volatiles applications. Whether for a primary analytical column or as a complementary confirmation column, Agilent J&W capillaries are chromatographers' first choice. Tips & Tools Find all the tools you need for column installation in Agilent's Column Installation Kit, P/N 430-2000. AGILENT J&W GC AND GC/MS COLUMNS 509 Volatiles Columns DB-VRX • Unique selectivity engineered for optimum resolution of volatiles analysis: U.S. EPA Methods 502.2, 524.2 and 8260 • 0.45 mm ID columns provide more plates per meter compared to 0.53 mm ID columns for the fewest coelutions for GC method (an industry first)* • No subambient cooling required to resolve the six "gases" • Fast run time: <30 minutes for optimum sample throughput <8 minutes with 0.18 mm ID • Low polarity • Excellent peak shape • Bonded and cross-linked • Solvent rinsable *Two coelutions: 1) m- and p-xylene, for which U.S. EPA does not require separation, and 2) 1,1,2,2-tetrachloroethane and o-xylene which are separated by detectors PID and ELCD, respectively. Note to GC/MS analysts: These coeluting compounds have different primary characteristic ions of 83 and 106, respectively. DB-VRX Chromatograms Environmental EPA Volatiles by GC/MS (Split Injector) High Speed VOC, EPA Method 8260 Unleaded Gasoline Extended Analyte List for EPA Method 8021 Page 604 Page 606 Page 569 Page 607 DB-VRX ID (mm) 0.18 0.25 0.32 0.45 510 Length (m) 20 40 30 60 30 60 30 75 GC AND GC/MS Film (µm) 1.00 1.00 1.40 1.40 1.80 1.80 2.55 2.55 Temp Limits (°C) -10 to 260 -10 to 260 -10 to 260 -10 to 260 -10 to 260 -10 to 260 -10 to 260 -10 to 260 7 in. Cage 121-1524 121-1544 122-1534 122-1564 123-1534 123-1564 124-1534 124-1574 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com 5 in. Cage 121-1544E 7890/6890 LTM Module 121-1524LTM 121-1544LTM 122-1534LTM 122-1564E 123-1534LTM 123-1564E 124-1534LTM 5975T LTM Toroid 221-1524LTM 222-1534LTM Volatiles Columns DB-624 • Specifically designed for the analysis of volatile priority pollutants and residual solvents • No cryogenics needed for U.S. EPA Method 502.2 • Excellent for U.S. EPA Methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240, 8260, and USP 467 • Excellent inertness for active compounds • Bonded and cross-linked • Solvent rinsable • Exact replacement of HP-624 • Equivalent to USP Phase G43 DB-624 Chromatograms Environmental EPA Volatiles by GC/MS II (Split Injector) European Red List Volatiles Extended Analyte List for EPA Method 8021 Fast VOC Analysis Page 605 Page 609 Page 607 Page 608 Food, Flavors and Fragrances Fusel Oil Standard & Brandy Sample Page 619 Industrial Chemicals Alcohols I Esters II Ethers Glycols II Halogenated Hydrocarbons I Nitrogen Based Solvents II Page 641 Page 653 Page 654 Page 655 Page 658 Page 663 Life Sciences Residual Solvents, DMI Diluent Residual Solvents, USP 467 Page 684 Page 684 Petroleum 1,3-Butadiene Page 690 AGILENT J&W GC AND GC/MS COLUMNS 511 Volatiles Columns DB-624 ID (mm) 0.18 0.20 0.25 0.32 0.45 0.53 Length (m) 20 25 30 60 30 60 30 75 15 30 60 75 Film (µm) 1.00 1.12 1.40 1.40 1.80 1.80 2.55 2.55 3.00 3.00 3.00 3.00 Temp Limits (°C) -20 to 280 -20 to 260 -20 to 260 -20 to 260 -20 to 260 -20 to 260 -20 to 260 -20 to 260 -20 to 260 -20 to 260 -20 to 260 -20 to 260 7 in. Cage 121-1324 128-1324 122-1334 122-1364 123-1334 123-1364 124-1334 124-1374 125-1314 125-1334 125-1364 125-1374 5 in. Cage 121-1324E 128-1324E 122-1334E 122-1364E 123-1334E 123-1364E 7890/6890 LTM Module 121-1324LTM 128-1324LTM 122-1334LTM 5975T LTM Toroid 221-1324LTM 222-1334LTM 123-1334LTM 124-1334LTM 125-1334E 125-1364E 125-1374E 125-1334LTM CP-Select 624 CB • Guaranteed for EPA volatiles with methods 524.2, 624 and 8015 for maximum confidence • Excellent peak shape for polar and basic compounds for accurate results • Specified by Pharmacopoeia Method V.3.3.9 for residual solvent analysis, providing compliancy The CP-Select 624 CB is a highly reproducible version of the popular 624 phase and has 2-3 times lower bleed (bleed specification for a 30 m, 0.53 mm, df = 3.00 µm is <9 pA) than conventional columns. The Select 624 CB, a 6% cyanopropylphenyl, 94% dimethylsiloxane phase is synthesized and fully characterized to ensure maximum column-to-column reproducibility. For an even lower bleed performance we recommend the VF-624ms. CP-Select 624 CB ID (mm) 0.15 0.25 0.32 0.53 512 GC AND GC/MS Length (m) 25 30 60 30 60 30 75 105 Film (µm) 0.84 1.40 1.40 1.80 1.80 3.00 3.00 3.00 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Temp Limits (°C) 265/280 265/280 265/280 265/280 265/280 265/280 265/280 265/280 7 in. Cage CP7411 CP7412 CP7413 CP7414 CP7415 CP7416 CP7417 CP7418 5 in. Cage CP7411I5 CP7413I5 CP7414I5 CP7415I5 CP7416I5 Volatiles Columns HP-VOC • Selectivity engineered for U.S. EPA Methods 502.2, 524.2 and 8260 • Low polarity – slightly more polar than DB-VRX • Excellent peak shape • Bonded and cross-linked • Solvent rinsable HP-VOC ID (mm) 0.20 0.32 0.53 Length (m) 30 60 60 90 90 105 Film (µm) 1.10 1.10 1.80 1.80 3.00 3.00 Temp Limits (°C) -60 to 280/290 -60 to 280/290 -60 to 280/290 -60 to 280/290 -60 to 280/290 -60 to 280/290 7 in. Cage 19091R-303 19091R-306 19091R-316 19091R-319 19095R-429 19095R-420 7890/6890 LTM Module 19091R-303LTM 5975T LTM Toroid 29091R-303LTM DB-502.2 • Available in 105 m for volatiles analyses • Excellent peak shape • Bonded and cross-linked • Solvent rinsable DB-502.2 ID (mm) 0.25 0.32 0.45 0.53 Length (m) 60 60 75 105 105 Film (µm) 1.40 1.80 2.55 2.55 3.00 Temp Limits (°C) 0 to 260/280 0 to 260/280 0 to 260/280 0 to 260/280 0 to 260/280 7 in. Cage 122-1464 123-1464 124-1474 124-14a4 124-14A4 AGILENT J&W GC AND GC/MS COLUMNS 513 Volatiles Columns DB-MTBE • Low polarity stationary phase • Resolves MTBE from 2-methylpentane and 3-methylpentane for better quantitation • Engineered for purge and trap injection without the need for cryofocusing • Bonded and cross-linked • Solvent rinsable DB-MTBE Chromatograms Environmental Methyl Tert-Butyl Ether (MTBE) FID, Extended 8020 Analysis Page 569 DB-MTBE ID (mm) 0.45 0.53 Length (m) 30 30 Film (µm) 2.55 3.00 Temp Limits (°C) 35 to 260/280 35 to 260/280 7 in. Cage 125-14A4 125-0034 5 in. Cage 125-0034E 7890/6890 LTM Module 124-0034LTM 125-0034LTM CP-Select CB for MTBE • Guaranteed analysis of MTBE in reformulated gasolines for reproducible results • Unique selectivity for ease-of-use with MTBE • Broad dynamic range for quantification of MTBE for the highest productivity CP-Select CB for MTBE ID (mm) 0.25 514 GC AND GC/MS Length (m) 50 Film (µm) 0.25 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Temp Limits (°C) 200/200 7 in. Cage CP7528 Volatiles Columns DB-TPH • Specifically designed for the analysis of total petroleum hydrocarbons (TPHs), soil analysis, and LUFT • Three analyses in one injection – gas range organics, diesel range organics and motor oil • Fast run time • Bonded and cross-linked • Solvent rinsable DB-TPH ID (mm) 0.32 0.45 Length (m) 30 30 Film (µm) 0.25 1.00 Temp Limits (°C) -10 to 320 -10 to 290 7 in. Cage 123-1632 124-1632 7890/6890 LTM Module 123-1632LTM Tips & Tools For a precision cut on your capillary column, use Agilent's GC column cutting tool (P/N 5183-4620). AGILENT J&W GC AND GC/MS COLUMNS 515 Volatiles Columns Select Mineral Oil • Optimized selectivity for more reliable results • Low bleed for better accuracy • Available in UltiMetal for ultimate longevity Total petroleum hydrocarbon (TPH) analysis is a routine technique used in environmental laboratories screening many samples. A simple and reliable method that provides the shortest analysis time is required. Select Mineral Oil is designed to meet this need, with a stabilized, non-polar bonded phase specifically for fast mineral oil analysis. The column is temperature stable up to 375/400°C and provides speedy analyses according to DIN H53 and DIN-EN-ISO 9377-2 methods. Thanks to the temperature stability of Select Mineral Oil, your C4 to C40 hydrocarbons can be analyzed in less then ten minutes. The high temperature stability of the column permits faster bakeout. For optimal injection performance be sure to use the special 4 m retention gap. Select Mineral Oils are available in economical three- and six-packs. Select Mineral Oil ID (mm) 0.32 Length (m) 15 15 15 Film (µm) 0.10 0.10 0.10 Temp Limits (°C) -60 to 390/400 -60 to 390/400 -60 to 390/400 Unit 1/pk 3/pk 6/pk 7 in. Cage CP7491 CP749103 CP749106 -60 to 325/350 3/pk CP8015 5 in. Cage CP7491I5 Retention gap 0.53 4 Select Mineral Oil UltiMetal ID (mm) 0.32 516 GC AND GC/MS Length (m) 15 Film (µm) 0.10 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Temp Limits (°C) -60 to 390/400 7 in. Cage CP7493 Metal Columns Metal Columns Recommended Metal Columns • CP-Sil 13 CB UltiMetal • CP-Sil 5 CB UltiMetal • CP-SIL 8 CB UltiMetal • CP-WAX 52 CB UltiMetal • FactorFour VF-5HT UltiMetal • CP-AL2O3/KCL UltiMetal • CP-AL2O3/NA2SO4 UltiMetal • CP-PoraPLOT Q UltiMetal • PLOT Molesieve 5Å UltiMetal DB-ProSteel • Excellent inertness • Virtually unbreakable • Available in a wide variety of stationary phases • Bonded and cross-linked • Ideal for high temperature analysis and process applications Our easy-to-handle DB-ProSteel metal columns are deactivated with a new formula (this is not glass lined steel) to provide inertness that truly rivals fused silica. DB-ProSteel metal columns can be custom wound upon request for small GC ovens. Several of our most popular bonded phases are available in metal. DB-ProSteel GC columns have the same outer diameter as standard Megabore (0.53 mm ID), so no special ferrules are required. AGILENT J&W GC AND GC/MS COLUMNS 517 Metal Columns DB-ProSteel Phase DB-PS1 ID (mm) 0.53 Length (m) 15 30 DB-PS624 DB-PSWAX DB-PS2887 0.53 0.53 0.53 30 30 10 Film (µm) 0.15 0.50 1.50 0.15 0.50 3.00 5.00 3.00 1.00 3.00 Tips & Tools For a comprehensive listing of chromatograms searchable by compound name, visit our online Chromatogram Library at www.agilent.com/chem/library 518 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Temp Limits (°C) -60 to 340/360 -60 to 300/320 -60 to 300/320 -60 to 340/360 -60 to 300/320 -60 to 260/280 -60 to 260/280 -20 to 260 20 to 230/240 -60 to 350 7 in. Cage 145-1011 145-1017 145-1012 145-1031 145-1037 145-1034 145-1035 145-1334 145-7032 145-2814 Non-Bonded Stationary Phases Non-Bonded Stationary Phases Whenever possible Agilent recommends the use of bonded and cross-linked polymers. Bonded polymers are more rugged, will have longer lifetimes and can be solvent rinsed. However, Agilent recognizes that some methods have been developed on non-bonded phases and therefore maintains these columns to support established methods. HP-101 • 100% Dimethylpolysiloxane Because HP-101 columns are not bonded or cross-linked, we do not recommend solvent rinsing. HP-101 ID (mm) 0.20 0.32 Length (m) 10 25 50 12 25 50 Film (µm) 0.20 0.20 0.20 0.25 0.30 0.30 Temp Limits (°C) -60 to 280 -60 to 280 -60 to 280 -60 to 280 -60 to 280 -60 to 280 7890/6890 7 in. Cage 5 in. Cage LTM Module 19091Y-101 19091Y-102 19091Y-102LTM 19091Y-105 19091-60010 19091-60010E 19091Y-012 19091Y-012E 19091Y-012LTM 19091Y-015 AGILENT J&W GC AND GC/MS COLUMNS 519 Non-Bonded Stationary Phases HP-17 • 50% Phenyl and 50% Methyl siloxane Because the HP-17 is not bonded or cross-linked, we do not recommend solvent rinsing. HP-17 ID (mm) 0.53 Length (m) Film (µm) 10 2.00 Temp Limits (°C) 25 to 260/280 7 in. Cage 19095L-121 7890/6890 LTM Module 19095L-121LTM CAM • Base deactivated polyethylene glycol • Specifically designed for amine analysis • Excellent peak shape for primary amines • Replaces HP-Basicwax Because the CAM is not bonded or cross-linked, we do not recommend solvent rinsing. CAM Chromatograms Industrial Chemicals Amines in Water Primary Amines Page 647 Page 645 CAM ID (mm) 0.25 520 Length (m) 15 30 0.32 60 30 0.53 30 GC AND GC/MS Film (µm) 0.25 0.25 0.50 0.25 0.25 0.50 1.00 Temp Limits (°C) 60 to 220/240 60 to 220/240 60 to 220/240 60 to 220/240 60 to 220/240 60 to 220/240 60 to 200/220 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com 7 in. Cage 112-2112 112-2132 112-2133 112-2162 113-2132 113-2133 115-2132 5 in. Cage 113-2132E 113-2133E 7890/6890 LTM Module 112-2112LTM 112-2132LTM 112-2133LTM 113-2132LTM 113-2133LTM 115-2132LTM Non-Bonded Stationary Phases Carbowax 20M and HP-20M • Polyethylene glycol, MW 20,000 • Equivalent to USP Phase G16 Because the Carbowax 20M and the HP-20M are not bonded or cross-linked, we do not recommend solvent rinsing. DB-WAX is the recommended bonded alternate for the HP-20M. Carbowax 20M ID (mm) 0.25 0.32 Length (m) 30 30 60 Film (µm) 0.25 0.25 0.25 Temp Limits (°C) 60 to 220/240 60 to 220/240 60 to 220/240 7 in. Cage 112-2032 113-2032 113-2062 7890/6890 LTM Module 112-2032LTM 113-2032LTM HP-20M ID (mm) 0.20 0.32 0.53 Length (m) 25 50 25 50 10 30 Film (µm) 0.10 0.10 0.30 0.30 1.33 1.33 Temp Limits (°C) 60 to 220 60 to 220 60 to 220 60 to 220 60 to 220 60 to 220 7 in. Cage 5 in. Cage 19091W-102 19091W-105 19091W-012 19091W-012E 19091W-015 19091W-015E 19095W-121 19095W-123 7890/6890 LTM Module 19091W-102LTM 19091W-012LTM 19095W-121LTM 19095W-123LTM AGILENT J&W GC AND GC/MS COLUMNS 521 Non-Bonded Stationary Phases DX-1 and DX-4 • DX-1: 90% Dimethylpolysiloxane 10% Polyethylene Glycol • DX-4: 15% Dimethylpolysiloxane 85% Polyethylene Glycol Because DX series GC columns are not bonded and cross-linked, we do not recommend solvent rinsing. DX-1 ID (mm) 0.25 0.32 Length (m) 30 30 Film (µm) 1.00 1.00 Temp Limits (°C) 50 to 250/270 50 to 250/270 7 in. Cage 122-6133 123-6133 Length (m) 30 60 15 30 60 Film (µm) 0.25 0.25 0.25 0.25 0.25 Temp Limits (°C) 50 to 250/270 50 to 250/270 50 to 250/270 50 to 250/270 50 to 250/270 7 in. Cage 122-6432 122-6462 123-6412 123-6432 123-6462 7890/6890 LTM Module 123-6133LTM DX-4 ID (mm) 0.25 0.32 522 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com 7890/6890 LTM Module 122-6432LTM 123-6412LTM 123-6432LTM Non-Bonded Stationary Phases SE-30 and SE-54 • SE-30: 100% Dimethylpolysiloxane • SE-54: (5%-Phenyl)(1%-Vinyl)-methylpolysiloxane Because SE series GC columns are not bonded or cross-linked, we do not recommend solvent rinsing. SE-30 ID (mm) 0.32 Length (m) 30 Film (µm) 0.25 Temp Limits (°C) 0 to 325/350 7 in. Cage 113-3032 Length (m) 30 60 30 Film (µm) 0.25 0.25 0.25 Temp Limits (°C) 0 to 325/350 0 to 325/350 0 to 325/350 7 in. Cage 112-5432 112-5462 113-5432 7890/6890 LTM Module 113-3032LTM SE-54 ID (mm) 0.25 0.32 7890/6890 LTM Module 112-5432LTM 113-5432LTM AGILENT J&W GC AND GC/MS COLUMNS 523 Packed GC Columns Packed GC Columns Stationary phases are available for the production of packed columns and coated packings. Stationary Phases for Packed GC Columns 524 A Antarox CO 630 Antarox CO 880 Antarox CO 990 Apiezon H Apiezon J Apiezon K Apiezon L Apiezon M Apiezon N Armeen SD B Bentone 34 Benzylcyanide-silver nitrate Bis(2-butoxyetylphthalate) Benzylpyridine C CP-Sil 34 CP-Sil 5 CP-Sil 58 CP-Sil 76 CP-Sil 8 CP-Sil 84 CP-Sil 88 CP-Wax 4000 M CP-Wax 600 M Cyano B Bis(2-ethoxyethyladipate) Bis(2-cyanoethyl)formamide N,NBis(2-ethoxyethylsebacate) Bis(2-methoxyethyl)adipate Butanediol succinate Bis(p-butoxybenziline)-α,α-bi-p-toluidine N,N- Decaglycerol Decane nDexsil 300 GC polymethylcarborane Dexsil 400 GC polymethylcarborane Dexsil 410 GC polymethylcarborane Di isodecyl-phthalate, DIDP Bis(p-methoxybenzilidine)-α,α-bi-p-toluidine N,N- Di isooctyl-adipate C Carbowax 1000 Carbowax 10000 Carbowax 1500 Carbowax 1540 Carbowax 200 Carbowax 20M Carbowax 20M TPA Carbowax 300 Carbowax 400 Carbowax 4000 Carbowax 4000 TPA Carbowax 550 Carbowax 600 Carbowax 6000 Carbowax 750 Castorwax Celanese ester Di isooctyl-phthalate Di isooctyl-sebacate, DEHS Di-n-decyl phthalate, DDP Di-n-octyl adipate Di-n-propyl phthalate Di-n-propyl tetrachlorophthalate Dioctoil Dioctyl phthalate Dioctyl sebacate (Octoil s) Dibenzyl ether Dibutyl maleate Dibutyl phthalate, DBP Dibutyl tetrachlorophthalate, DBTP Diethylene glycol Diethylene glycol adipate, DEGA, cross linked Diethylene glycol adipate, DEGA Diethylene glycol sebacate, DEGSe Diethylene glycol succinate, DEGS GC AND GC/MS Cyanoethyl sucrose Cyanoethyl sucrose, CES Cyclo N Cyclohexane dimethanol succinate, CDS D www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Packed GC Columns Stationary Phases for Packed GC Columns D Diglycerol Dimer acid Dimethylformamide, DMF Dimethyl sulfolane, DMS 2,4Dimethanol cyclohexane succinate, CDS Dimethyl sulfoxide, DMSO Dinonyl phthalate Dinonyl sebacate DOW corning 705 Dow fax 9 N 40 Dowfax 9N9 H Hexadecene Hexadecanol Hexakis(2-cyanoethoxy)cyclohexane 1,2,3,4,5,6Hexamethyl phosphoramide, HMPA HI-EFF 1 AP HI-EFF 1 BP HI-EFF 3 AP HI-EFF 3 B HI-EFF 8 BP Hyprose SP-80, (octakis-(2-hydroxypropyl)sucrose) I E EGSS-X Emulphor ON-870 Epon 1001, epoxy resin Ethofat 60/25 Ethylbenzene Ethylene glycol adipate, EGA Ethylene glycol isophthalate Ethylene glycol isophthalate EGIP Ethylene glycol phthalate Ethylene glycol sebacate Ethylene glycol succinate Ethylene glycol tetrachlorophthalate F Isoquinoline K FFAP Fluorad FC 431 Fluorene Fluorolube GR-362 Fyrquel 220 G Glycerol H H3PO4 (Phosphoric acid) Hallcomid M-18, dimethylstearamide Hallcomid M-18-OL, dimethyloleamide Halocarbon K-352 Halocarbon oil 10.25 Halocarbon wax Hexadecane Kel F grease Kel F oil no. 10 Kel F oil no. 3 Kel F wax KOH (potassium hydroxide) L LAC 1 R 296 LAC 10 R 744 LAC 12 R 796 LAC 17-R-770 LAC 22 R 863 Lexan (polycarbonate resin) M Mannitol Montan wax N Neopentyl glycol adipate Neopentyl glycol sebacate Neopentyl glycol succinate Nitrobenzene Nujol (paraffin oil) O Octadecane nOctadecene nOctoil Olive oil Oronite NIW AGILENT J&W GC AND GC/MS COLUMNS 525 Packed GC Columns Stationary Phases for Packed GC Columns O Oronite polybutene 128 Oronite polybutene 32 OS-124 (PMPE 5 ring) OS-138 (PMPE 6 ring) P Palladium Paraffin oil Paraffin wax Pentanediolsuccinate; 1,5Phenyl diethanolamine Phenyl diethanolamine succinate Pluronic P84 Poly-A 101A (polyamide) Poly-A 103 (polyamide) Poly-A 135 (polyamide) Poly-L 110 (polyamide) Poly-m-phenyl ether 5 ring Poly-m-phenoxylene, PPE-21 Poly-m-phenyl ether 6 ring Poly-S 179 Polyethylene glycol 2000 Polyethylene glycol 600, Jefferson Polyethylene imine Polypropylene glycol 2000 Polypropylene glycol 3500 Polypropylene glycol 4000 Polypropylene imine Polyvinylpyrrolidone Q Quadrol R Reoplex 4000 S Sebaconitrile Silar 10 C Silar 5 CP highly polar Silar 7 C Silar 9 C Silicone AN-600 (50% cyanoethyl) Silicone DC 111 grease 526 GC AND GC/MS S Silicone DC 200 Silicone DC 410 Silicone DC 550 Silicone DC 560 Silicone DC 702 Silicone DC-704 Silicone DC 710 Silicone fluid MS 550 Silicone OV-1 Silicone OV-101 Silicone OV-105 Silicone OV-11 Silicone OV-17 Silicone OV-1701 Silicone OV-202 Silicone OV-210 Silicone OV-215 Silicone OV-22 Silicone OV-225 Silicone OV-25 Silicone OV-275 Silicone OV-3 Silicone OV-330 Silicone OV-351 Silicone OV-61 Silicone OV-7 Silicone OV-73 Silicone QF-1 Silicone SE-30 Silicone SE-30 GC Grade Silicone SE-52 Silicone SE-54 Silicone SF-96 Silicone UC W-98 Silicone UC W-982 Silver nitrate Sorbitol SP-1000 SP-1200 SP-2100 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Packed GC Columns Stationary Phases for Packed GC Columns S SP-2250 SP-2300 SP-2310 SP-2330 SP-2340 SP-2401 SP-300 Span-80 Squalane Squalene Sucrose acetate isobutyrate Sucrose-octa acetate Supelco SP-216 PS Surfonic N-300 T Terephthalic acid Tergitol NP-35 Tergitol NPX Tetra ethylene glycol Tetracyanoethyl pentaerythritol Tetraethylene glycol dimethyl ether Tetraethylene pentamine Tetrahydroxyethylenediamine Thiodipropionitrile β,β- U UC-L-45 UCON 50 HB 2000 UCON 50 HB 280X UCON 50 HB 5100 UCON 75 H 90000 UCON LB 1200X UCON LB 1715 UCON LB 1800X UCON LB 550X UCW-98 UC W-982 V Versamid 900 (polyamide resin) Tri(tetra hydrofuryl)phosphate Triacetin Tributylphosphate Triethanolamine Trimer acid Trimethylol pelargonate Triton X-100 Tris(2-cyanoethoxy)propane 1,2,3Tritolyl phosphate Triton X-305 Tween-80 AGILENT J&W GC AND GC/MS COLUMNS 527 Packed GC Columns Supports for Packed GC Columns Supports are available for the production of packed columns and coated packings. Supports for Packed GC Columns Description Activated charcoal Activated charcoal Activated charcoal Alumina GC Alumina GC Alumina GC Carbopack B Carbopack B Carbopack C Carbopack C Carbosieve G Carbosieve G Carbosieve S II Carbosieve S II Carbosieve S III Carbosieve S III Carbosphere Carbosphere Chromosorb 101 Chromosorb 101 Chromosorb 101 Chromosorb 102 Chromosorb 102 Chromosorb 102 Chromosorb 102 Chromosorb 103 Chromosorb 103 Chromosorb 105 Chromosorb 105 Chromosorb 106 Chromosorb 106 Chromosorb 106 Chromosorb 107 Chromosorb 107 Chromosorb 108 Chromosorb 108 Chromosorb 750 Chromosorb G AW Chromosorb G AW Chromosorb G AW Chromosorb G AW DMCS 528 GC AND GC/MS Mesh Size 40-60 60-80 80-100 40-60 60-80 80-100 60-80 80-100 60-80 80-100 60-80 80-100 60-80 80-100 60-80 80-100 60-80 80-100 60-80 80-100 100-120 20-40 60-80 80-100 100-120 80-100 100-120 80-100 100-120 60-80 80-100 100-120 80-100 100-120 80-100 100-120 80-100 60-80 80-100 100-120 60-80 Description Chromosorb G AW DMCS Chromosorb G AW DMCS Chromosorb G HP Chromosorb G HP Chromosorb G HP Chromosorb G HP Chromosorb G NAW Chromosorb G NAW Chromosorb G NAW Chromosorb G NAW Chromosorb P Chromosorb P Chromosorb P Chromosorb P Chromosorb P Chromosorb P AW Chromosorb P AW Chromosorb P AW Chromosorb P AW Chromosorb P AW DMCS Chromosorb P AW DMCS Chromosorb P AW DMCS Chromosorb P AW DMCS Chromosorb P NAW Chromosorb P NAW Chromosorb P NAW Chromosorb P NAW Chromosorb T Chromosorb T Chromosorb W AW Chromosorb W AW Chromosorb W AW Chromosorb W AW Chromosorb W AW DMCS Chromosorb W AW DMCS Chromosorb W AW DMCS Chromosorb W AW DMCS Chromosorb W HMDS Chromosorb W HMDS Chromosorb W HMDS Chromosorb W HMDS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Mesh Size 80-100 100-120 45-60 60-80 80-100 100-120 45-60 60-80 80-100 100-120 20-40 40-60 60-80 80-100 100-120 45-60 60-80 80-100 100-120 45-60 60-80 80-100 100-120 45-60 60-80 80-100 100-120 30-60 40-60 40-60 60-80 80-100 100-120 45-60 60-80 80-100 100-120 45-60 60-80 80-100 100-120 Packed GC Columns Supports for Packed GC Columns Description Chromosorb W HP Chromosorb W HP Chromosorb W HP Chromosorb W NAW Chromosorb W NAW Chromosorb W NAW Glass beads regular Glass beads regular Glass beads regular Glass beads regular Hayesep A Hayesep A Hayesep A Hayesep B Hayesep B Hayesep B Hayesep C Hayesep C Hayesep C Hayesep N Hayesep N Hayesep N Hayesep P Hayesep P Hayesep P Hayesep Q Hayesep Q Hayesep Q Hayesep R Hayesep R Hayesep R Hayesep S Hayesep S Hayesep S Hayesep T Hayesep T Hayesep T Molecular sieve 5Å Molecular sieve 5Å Molecular sieve 5Å Molecular sieve 5Å Molecular sieve 13X Molecular sieve 13X Molecular sieve 13X Mesh Size 60-80 80-100 100-120 60-80 80-100 100-120 45-60 60-80 80-100 100-120 60-80 80-100 100-120 60-80 80-100 100-120 60-80 80-100 100-120 60-80 80-100 100-120 60-80 80-100 100-120 60-80 80-100 100-120 60-80 80-100 100-120 60-80 80-100 100-120 50-80 80-100 100-120 45-60 60-80 80-100 100-120 60-80 80-100 100-120 Description Porapak N Porapak N Porapak N Porapak P Porapak P Porapak P Porapak PS Porapak PS Porapak Q Porapak Q Porapak Q Porapak QS Porapak QS Porapak QS Porapak R Porapak R Porapak R Porapak S Porapak S Porapak S Porapak T Porapak T Porapak T Porasil B Porasil C Silica gel GC grade Silica gel GC grade Silica gel GC grade Silocel Silocel Silocel Silocel Spherosil XOB 75 Tenax GR Tenax GR Tenax GR Tenax TA Tenax TA Tenax TA Tenax TA W KOH washed W KOH washed W KOH washed W KOH washed Mesh Size 50-80 80-100 100-120 50-80 80-100 100-120 50-80 80-100 50-80 80-100 100-120 50-80 80-100 100-120 50-80 80-100 100-120 50-80 80-100 100-120 50-80 80-100 100-120 80-100 80-100 30-40 45-60 60-80 45-60 60-80 80-100 100-120 100-120 35-60 60-80 80-100 20-35 35-60 60-80 80-100 45-60 60-80 80-100 100-120 AGILENT J&W GC AND GC/MS COLUMNS 529 Custom GC Columns Custom GC Column Ordering Even though we offer over a thousand readily available columns, Agilent recognizes that sometimes you need something a little out of the ordinary. That's why we developed our Custom Column Shop. If you can't find what you're looking for in our standard order guides, we will design, build, and test capillary GC columns to meet your needs. • We can create columns with non-standard lengths or unusual film thickness. • We can connect columns together in series or as dual columns. • We recognize that sometimes customers have specific column performance requirements for their applications that might not be met with standard test mixes. As a result we can also custom-test your columns with your desired test mixture and test conditions to meet your specific performance requirements. • We can create DuraGuard columns with an integrated guard column. Most phases can be manufactured with a built-in guard column which means you get the advantages of a guard column without the union. Only available in DB-phases. Custom columns are ordered using P/N 100-2000. Be sure to provide the details of your desired custom service or column including phase, length, ID, and film thickness. Contact your local Agilent office or Authorized Agilent Distributor to receive a quote for your custom column needs. You can find order forms in the back of the catalog. Customers in the United States, Canada, and Puerto Rico can request a custom column quote online at www.agilent.com/chem/CustomColumn 530 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Agilent J&W GC Column Test Standards Tech Support Need assistance selecting a column for your method? Contact our chromatography technical specialists at www.agilent.com/chem/TechRep Agilent J&W GC Column Test Standards Compare your column's performance to the test chromatogram shipped with your J&W column from Agilent. The column test standard contains components that test the column for resolution characteristics, efficiency, and inertness. The test mixes are supplied at a concentration of 250 ng/µL in 2 mL vials. Match the phase and column diameter in the chart below to find the test mix for your column. Agilent J&W GC Column Test Standards Column Description OV-351 DB-1ht DB-1 DB-5 DB-5ht DB-5ms DB-624 DB-2887 DB-WAX DB-WAXetr SE-30 SE-52 SE-54 HP-1 HP-5 HP-FFAP GS-OxyPLOT Microbore (0.05 & 0.10 mm ID) Part No. 200-0010 200-0010 200-0070 8500-6813 Capillary (0.18 & 0.32 mm ID) Part No. 200-0032 200-0010 200-0310 200-0310 200-0010 200-0185 200-0113 200-0370 200-0370 200-0010 200-0010 200-0010 5080-8858 5080-8858 8500-6813 Megabore (0.45 & 0.53 mm ID) Part No. 200-0110 200-0110 200-0185 200-0113 200-0110 200-0070 200-0070 200-0010 8500-6812 8500-6812 8500-6813 5188-5379 AGILENT J&W GC AND GC/MS COLUMNS 531 Fused Silica Tubing Fused Silica Tubing Deactivated Tubing Deactivated tubing can be used as retention gaps, guard columns, or transfer lines. Our standard deactivation process is a phenyl methyl deactivation – the preferred choice for most applications due to its inertness and robustness. Deactivated Fused Silica ID (mm) 0.05 OD (mm) 0.36 0.10 0.19 0.36 532 GC AND GC/MS 0.15 0.36 0.18 0.34 0.20 0.36 0.25 0.36 0.32 0.43 0.45 0.67 0.53 0.67 www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Length (m) 1 5 10 1 5 10 1 5 5 10 1 5 10 1 5 10 1 5 10 1 5 10 30 1 5 10 30 1 5 10 1 5 10 30 Part No. 160-2655-1 160-2655-5 160-2655-10 160-1010-1 160-1010-5 160-1010-10 160-2635-1 160-2635-5 19091-60620E 160-2635-10 160-2625-1 160-2625-5 160-2625-10 160-2615-1 160-2615-5 160-2615-10 160-2205-1 160-2205-5 160-2205-10 160-2255-1 160-2255-5 160-2255-10 160-2255-30 160-2325-1 160-2325-5 160-2325-10 160-2325-30 160-2455-1 160-2455-5 160-2455-10 160-2535-1 160-2535-5 160-2535-10 160-2535-30 Fused Silica Tubing Deactivated Fused Silica High Temperature (400°C) ID (mm) 0.05 0.10 0.25 OD (mm) 0.36 0.36 0.35 0.32 0.43 0.53 0.67 Length (m) 5 5 5 10 5 10 5 10 Part No. 160-2815-5 160-2825-5 160-2845-5 160-2845-10 160-2855-5 160-2855-10 160-2865-5 160-2865-10 ProSteel Deactivated Fused Silica ID (mm) 0.53 OD (mm) 0.67 Length (m) 5 Part No. 160-4535-5 Undeactivated Fused Silica Undeactivated tubing or bare fused silica is commonly used for capillary electrophoresis. It can also be used for transfer lines and other applications where inertness is not critical. Undeactivated Fused Silica ID (mm) 0.02 0.05 OD (mm) 0.36 0.36 0.075 0.36 0.10 0.36 0.18 0.34 0.20 0.36 0.25 0.36 0.32 0.43 0.45 0.67 0.53 0.67 Length (m) 5 5 10 5 10 5 10 5 10 5 10 50 5 10 5 10 50 5 10 5 10 Part No. 160-2660-5 160-2650-5 160-2650-10 160-2644-5 160-2644-10 160-2634-5 160-2634-10 160-2610-5 160-2610-10 160-2200-5 160-2200-10 19091-20050 160-2250-5 160-2250-10 160-2320-5 160-2320-10 19091-21050 160-2450-5 160-2450-10 160-2530-5 160-2530-10 AGILENT J&W GC AND GC/MS COLUMNS 533 GC Column Application and Method Guides GC Column Application and Method Guides Application Specific Application Agilent Phase Biodiesel EN14105 Free/Total Glycerin ASTM D6584 Free/Total Glycerin EN14103 FAME Analysis EN14110 Residual Methanol EN14106 Free Glycerol Chiral γ-lactones and terpenes Biodiesel, Select Biodiesel Biodiesel, Select Biodiesel Biodiesel, Select Biodiesel Biodiesel, Select Biodiesel Select Biodiesel CycloSil-B Optical isomers of acids, alcohols, amino acids, aromatic hydrocarbons, diols, flavors, aromas, ketones, organic acids and phenols Chiral compounds using a nitrogen selective detector Cyclodex-B Optical isomers of acids, alcohols, amino acids, aromatic, diols, flavor, aromas, ketones, organic acids and phenols Amino acids, optical isomers CP-Chirasil-Dex CB, CP-Cyclodextrin-β-2,3,6-M-19 FAME up to C26, cis, trans, fast resolution FAME Best separation for cis, trans FAME up to 260°C Volatiles Unsaturated triglycerides Flavors, aromas, free fatty acids C1-C26 Glycols, diols, alcohols Blood alcohol analysis Blood alcohol analysis Drugs of abuse confirmation USP solvents, common solvents Drugs of abuse confirmation Organochlorine pesticides Organochlorine pesticides Chlorinated pesticides and PCBs Trace levels of pesticides in food and environmental samples Chlorinated, nitrogen, phosphorus pesticides and PCBs Chlorinated, nitrogen, phosphorus pesticides Chlorinated, nitrogen, phosphorus pesticides, trace level DDT and Endrin Select FAME CP-Sil 88 for FAME CP-Carbowax 400 for Volatiles in Alcohol CP-TAP CB for Triglycerides CP-FFAP CB CP-Wax 57 CB for Glycols and Alcohols DB-ALC1 and DB-ALC2 HP-Blood Alcohol DB-5ms EVDX HP-Fast Residual Solvent VF-DA HP-PAS5 DB-1701P DB-608 VF-5 Pesticides and VF-1701 Pesticides Chiral Foods, Flavors and Fragrances Life Sciences Pesticides 534 GC AND GC/MS HP-Chiral β CP-Chirasil-Dex CB, CP-Cyclodextrin-β-2,3,6-M-19 Rapid-MS CP-Sil 8 CB for Pesticides CP-Sil 19 CB for Pesticides www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com GC Column Application and Method Guides Application Specific Application Agilent Phase Polycyclic Aromatic Hydrocarbons EU regulated PAHs PAHs in environmental and food samples C5-C80, PAH and polar compounds EU and EPA regulated PAHs Petroleum Simulated distillation using ASTM Method D2887 C6-C110+ C5-C100 simulated distallation C5-C120 simulated distallation PONA and PIANO analysis Paraffins, aromatics, naphthenes and olefins C4-C20 ASTM D 5134 PONA and PIANO analysis High temperature simulated distallation C1-C10 hydrocarbons C1-C6 alcohols, aromatic C6-C10 Hydrogen, sulfide, carbonyl sulfide, methanethiol, ethanethiol and thiophenes in LPG Polar and non-polar volatile compounds, especially chlorosilanes with different substituents such as alkyl groups, or groups with ether, hydroxy and nitrile bonds C1-C6 amines, alcohols, NH3, water, solvents, ethanol amines C3-C20 amines, alkanol amines C3-C8 amines and diamines C4-C10 amines, diamines and aromatic amines Oxygenates in C1-C10 hydrocarbons C1-C10 hydrocarbons Methanol, formaldehyde and formic acid in water C1-C12 hydrocarbons Volatile oxygenates and halogenated hydrocarbons Semivolatiles Polychlorinated dibenzodioxins (PCDDs) and dibenzofurans (PCDFs) Dioxins and dibenzo furan EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols PCB, detailed analysis PCB DB-EUPAH Select PAH CP-Sil PAH CB UltiMetal VF-17ms for PAH DB-2887 DB-HT SimDis CP-SimDist CP-SimDist UltiMetal HP-PONA CP-Sil PONA CB CP-Sil PONA for ASTM D 5134 DB-Petro HP-1 Aluminum Clad Select Al2O3 MAPD CP-TCEP for Alcohols in Gasoline CP-Sil 5 CB for Sulfur Select Silanes CP-Volamine CP-Sil 8 CB for Amines CP-Wax for Volatile Amines and Diamines CP-Wax 51 for Amines CP-Lowox GS-OxyPLOT CP-Sil 5 CB for Formaldehyde CP-Squalane CP-Propox DB-Dioxin CP-Sil 88 for Dioxins DB-5.625 HP-5ms Semivolatile CP-Sil 5/C18 CB for PCB CP-Sil 8 CB for PCB AGILENT J&W GC AND GC/MS COLUMNS 535 GC Column Application and Method Guides Application Specific Application Agilent Phase Volatiles EPA Methods 502.2, 524.2 and 8260 Volatile priority pollutants and residual solvents Halogenated hydrocarbons and solvents EPA Methods 502.2, 524.2 and 8260 EPA Method 502.2 MTBE in soil and water Oxygenates and solvents Total petroleum hydrocarbons (TPHs), soil analysis, and LUFT C5-C40 hydrocarbons High temperature analysis and process applications Amino acid derivatives, essential oils Drugs, glycols, pesticides, steroids Amines, basic compounds Alcohols, free acids, essential oils, ethers, glycols, solvents Generic DB-VRX DB-624 CP-Select 624 CB HP-VOC DB-502.2 DB-MTBE CP-Select CB for MTBE DB-TPH Metal Non-Bonded Select Mineral Oil DB-ProSteel HP-101 HP-17 CAM Carbowax 20M and HP-20M SE-30 and SE-54 Agilent Phase Composition Application Ultra Inert Columns DB-1ms Ultra Inert HP-1ms Ultra Inert DB-5ms Ultra Inert HP-5ms Ultra Inert DB-35ms Ultra Inert 100% Dimethylpolysiloxane 100% Dimethylpolysiloxane 5% Phenyl 95% dimethyl arylene siloxane 5% Phenyl 95% dimethylpolysiloxane 5% Phenyl 65% dimethylpolysiloxane Semivolatiles, halogenated compounds, pesticides, herbicides, drugs of abuse, amines, unknown sample screening General Application Columns DB-1ms HP-1ms VF-1ms DB-5ms HP-5ms VF-5ms DB-XLB VF-Xms DB-35ms VF-35ms 100% Dimethylpolysiloxane Amines, hydrocarbons, pesticides, PCBs, phenols, sulfur compounds, flavors and fragrances 5% Phenyl 95% dimethyl arylene siloxane 5% Phenyl 95% dimethylpolysiloxane Semivolatiles, alkaloids, drugs, FAMEs, halogenated compounds, pesticides, herbicides High arylene modified 5% Phenyl 65% dimethylpolysiloxane Pesticides, herbicides, PCBs and PAHs Pesticides, herbicides, PCBs and PAHs Aromatic compounds, pesticides and herbicides, sterols and other substituted aromatic compounds (Continued) 536 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com GC Column Application and Method Guides Agilent Phase Composition Application General Application Columns DB-17ms VF-17ms VF-23ms VF-200ms 50% Phenyl 50% dimethylpolysiloxane Antidepressants, herbicides and pesticides High cyanopropyl modified Trifluoropropyl methyl DB-225ms VF-624ms 50% Cyanopropylphenyl 50% dimethylpolysiloxane 6% Cyanopropyl-phenyl 94% dimethylpolysiloxane VF-1301ms 6% Cyanopropyl-phenyl 94% dimethylpolysiloxane VF-WAXms VF-1701ms Polyethylene glycol 14% Cyanopropyl-phenyl 86% dimethylpolysiloxane DB-1 HP-1 CP-Sil 5 CB Ultra 1 Ultra 2 DB-5 HP-5 CP-Sil 8 CB CP-Sil 13 CB 100% Dimethylpolysiloxane FAME, solvents, sugars Ketones, aldehydes, nitro- or chloro-containing compounds, PAHs, unsaturated compounds, silanes and CFCs FAMEs, alditol acetates, neutral sterols Purgeable organic volatiles and semi-volatiles, aromatics, halocarbons, solvents Thin-film version of the VF-624ms suitable for volatile solvents, pesticides, PCBs and other organic compounds requiring thin films Trace analysis of polar substances Organic compounds in drinking water, base/neutrals and acids, PCBs and chlorinated pesticides, organophosphorus pesticides and herbicides Amines, hydrocarbons, pesticides, PCBs, phenols, sulfur compounds, flavors and fragrances DB-35 HP-35 DB-17 HP-50+ CP-Sil 24 CB DB-23 HP-88 CP-Sil 88 100% Dimethylpolysiloxane 100% Dimethylpolysiloxane 5% Phenyl 95% dimethylpolysiloxane 14% Phenyl 86% dimethylpolysiloxane Semivolatiles, alkaloids, drugs, FAMEs, halogenated compounds, pesticides, herbicides 35% Phenyl 65% dimethylpolysiloxane Analysis of medium-polarity compounds where halocarbon-sensitive detectors are used (e.g. ECD) Amines, aromatic hydrocarbons, EPA methods, fungicides, halogenated compounds, herbicides, pesticides, PCBs, phenols, phthalate esters, steroids, sugars and tranquilizers CLP-pesticides, aroclors, pharmaceuticals, drugs of abuse 50% Phenyl 50% dimethylpolysiloxane Drugs, glycols, pesticides, steroids 50% Cyanopropyl 50% methylpolysiloxane 88% Vyanopropyl 12% aryl-polysiloxane Highly substituted, stabilized cyanopropyl Antidepressants, herbicides and pesticides FAMEs FAMEs Dioxins, FAME, PCBs, PCDFs, pyridines and sugars (Continued) AGILENT J&W GC AND GC/MS COLUMNS 537 GC Column Application and Method Guides Agilent Phase Composition Application General Application Columns DB-200 DB-210 DB-225 CP-Sil 43 CB DB-1301 CP-1301 DB-1701 CP-Sil 19 CB 35% Trifluoropropyl 65% dimethylpolysiloxane 50% Trifluoropropyl 50% dimethylpolysiloxane 50% Cyanopropylphenyl 50% dimethylpolysiloxane 25% Cyanopropyl 25% phenyl 50% dimethylpolysiloxane 6% Cyanopropylphenyl 94% dimethylpolysiloxane 14% Cyanopropylphenyl 86% dimethylpolysiloxane Residual solvents, pesticides, herbicides EPA Methods 8140 and 609 FAMEs, alditol acetates, neutral sterols FAME, halogenated compounds, phenols and pyridines Aroclors, alcohols, pesticides, VOCs Herbicides, pesticides and many pharmaceutical products Pesticides, herbicides, TMS sugars, aroclors Trace levels of pesticide residues in food and environmental samples Polyethylene Glycol (PEG) Columns DB-WAX HP-INNOWax Polyethylene glycol CP-Wax 52 CB DB-FFAP HP-FFAP CP-Wax 58 FFAP CB Polyethylene glycol-acid modified CP-Wax 57 CB Polyethylene glycol Solvents, glycols, alcohols Alcohols, free organic acids, solvents, essential oils, flavors and fragrances Alcohols, aldehydes, anesthetics, antidepressants, aromatic hydrocarbons, EPA methods, esters, FAME, flavors and aromas, glycols, halogenated components, ketones, nitro compounds, PAHs, phenols, solvents and sulfur compounds Organic acids, alcohols, aldehydes, ketones, acrylates FAME, flavors and aromas, free fatty acids, organic acids and phenols Alcohols, aromatic hydrocarbons, esters, FAME, flavors and aromas, free fatty acids, glycols, halogenated compounds, ketones, organic acids and solvents PLOT Columns CP-PoraBOND Q Styrene-divinylbenzene copolymer CP-PoraBOND U Styrene-glycol methacrylate copolymer CP-PoraPLOT Q Styrene-divinylbenzene copolymer CP-PoraPLOT Q-HT Styrene-divinylbenzene copolymer Alcohols, free fatty acids, gases, glycols, halogenated compounds, hydrocarbons, C1-C9, ketones, solvents, sulfur compounds Alcohols, free fatty acids, gases, glycols, halogenated compounds, hydrocarbons, C1-C9, ketones, solvents, sulfur compounds Alcohols, free fatty acids, gases, glycols, halogenated compounds, hydrocarbons, C1-C9, ketones, solvents, sulfur compounds Halogenated compounds, hydrocarbons C1-C9, ketones, oxygenated hydrocarbons, permanent gases, solvents (Continued) 538 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com GC Column Application and Method Guides Agilent Phase Composition Application PLOT Columns HP-PLOT Q GS-Q CP-PoraPLOT U CP-PoraPLOT S HP-PLOT U HP-PLOT Al2O3 KCl GS-Alumina KCl CP-Al2O3/KCl CP-Al2O3/Na2SO4 HP-PLOT Al2O3 S GS-Alumina HP-PLOT Al2O3 M GS-GasPro CP-SilicaPLOT CP-CarboBOND CP-CarboPLOT P7 GS-CarbonPLOT HP-PLOT Molesieve CP-Molsieve 5Å CP-PoraPLOT Amines Polystyrenedivinylbenzene Hydrocarbons including isomers, CO2, methane, air/CO, water, polar solvents, sulfur compounds Porous divinylbenzene homopolymer Hydrocarbons, halogenated hydrocarbons, sulfides except for SO2 Ethylene glycol dimethacrylate-divinylbenzene copolymer Halogenated compounds, hydrocarbons C1-C6, ketones, oxygenated hydrocarbons, permanent gases and solvents Vinylpyridine-divinylbenzene copolymer Hydrocarbons, ketones Divinylbenzene/ethylene glycol dimethacrylate C1-C7 hydrocarbons, CO2, methane, air/CO, water, oxygenates, amines, solvents, alcohols, ketones, aldehydes Aluminum oxide KCl deactivated C1-C6 hydrocarbons in natural gas, refinery gas, fuel gas, synthetic gas, dienes Aluminum oxide KCl deactivated C1-C6 hydrocarbons in natural gas, refinery gas, fuel gas, synthetic gas, dienes Aluminium oxide Hydrocarbons C1-C10 and impurities in hydrocarbon mainstreams, benzene and toluene Aluminium oxide Hydrocarbons C1-C10 and impurities in hydrocarbon mainstreams, benzene and toluene Aluminum oxide "Sodium Sulfate" deactivated C1-C6 hydrocarbons in natural gas, refinery gas, fuel gas, synthetic gas, dienes Aluminum oxide with proprietary deactivation C1-C6 hydrocarbons in natural gas, refinery gas, fuel gas, synthetic gas, dienes Aluminium oxide C1-C6 hydrocarbons in natural gas, refinery gas, fuel gas, synthetic gas, dienes Proprietary, bonded silica-based C1-C12 hydrocarbons, CO2, trace-level sulfurs, hydride gases, inorganic gases, halocarbons, SF6, oxygen/nitrogen separation at -80°C Proprietary, bonded silica-based COS in ethylene, freons/CFCs, hydrocarbons, propylene and sulfur gases Active carbon Hydrocarbons in ethylene and traces CO and CO2 in ethylene and propylene Active carbon He, Xe, CO, Ne, CH4, CO2, O2/Ar, C2H6, N2, C2H4, Kr, and C2H2 Bonded monolithic carbon layer C1-C5 hydrocarbons, CO2, air/CO, trace acetylene in ethylene, methane 5Å molecular sieve zeolite Permanent and noble gases. Argon and oxygen separation at 35°C Molecular sieve He, H2, O2, CO, Ne, HD, N2, NO, Ar, D2, CH4, KrHT, Xe, DT, CD4, Rn, T2 Styrene-divinylbenzene copolymer base deactivated Amines C1-C6 AGILENT J&W GC AND GC/MS COLUMNS 539 GC Column Application and Method Guides EPA Method Drinking Water EPA Method Application 501, 501.3 502.2 503.1 504.1 505 506 507 508 508.1 Recommended Column Measurement of trihalomethanes in drinking water GC/MS and selected ion monitoring VF-624ms, 30 m x 0.53 mm, 3.00 µm VF-624ms, 30 m x 0.25 mm, 1.40 µm DB-VRX, 30 m x 0.45 mm, 2.55 µm DB-624, 30 m x 0.45 mm, 2.55 µm Volatile organic compounds in water by purge and trap VF-624ms, 75 m x 0.53 mm, 3.00 µm capillary column GC with photoionization and VF-624ms, 30 m x 0.53 mm, 3.00 µm electrolytic conductivity detectors in series VF-624ms, 30 m x 0.25 mm, 1.40 µm DB-VRX, 75 m x 0.45 mm, 2.55 µm DB-624, 75 m x 0.45 mm, 2.55 µm Volatile aromatic and unsaturated organic compounds DB-VRX, 30 m x 0.45 mm, 2.55 µm in water by purge and trap gas chromatography DB-624, 30 m x 0.45 mm, 2.55 µm 1,2-Dibromoethane (EDB) and 1,2-dibromo-3VF-1ms, 30 m x 0.32 mm, 1.00 µm chloropropane (DB CP), GC, microextraction VF-1701ms, 30 m x 0.32 mm, 1.00 µm DB-VRX, 30 m x 0.45 mm, 2.55 µm DB-624, 30 m x 0.45 mm, 2.55 µm Analysis of organohalide pesticides and commercial VF-1ms, 30 m x 0.32 mm, 1.00 µm polychlorinated biphenyl (PCB) products in water by VF-17ms, 30 m x 0.32 mm, 0.50 µm microextraction and GC Determination of phthalate and adipate esters in VF-5ms, 30 m x 0.32 mm, 0.25 µm drinking water by liquid-liquid extraction or liquid-solid VF-1ms, 30 m x 0.32 mm, 0.25 µm extraction and GC with photoionization detection DB-5ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.53 mm, 1.50 µm DB-608, 30 m x 0.53 mm, 0.50 µm Determination of nitrogen and phosphorus-containing VF-5 Pesticides, 30 m x 0.25 mm, 0.25 µm pesticides in water by GC with a nitrogen-phosphorus VF-1701 Pesticides, 30 m x 0.25 mm, 0.25 µm detector DB-35ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm Determination of chlorinated pesticides in water GC VF-5 Pesticides, 30 m x 0.25 mm, 0.25 µm with an electron capture detector VF-1701 Pesticides, 30 m x 0.25 mm, 0.25 µm Determination of chlorinated pesticides, herbicides, and VF-5 Pesticides, 30 m x 0.25 mm, 0.25 µm organohalides by liquid-solid extraction and electron DB-35ms, 30 m x 0.32 mm, 0.25 µm capture GC DB-XLB, 30 m x 0.32 mm, 0.50 µm Part No. CP9106 CP9102 124-1534 124-1334 CP9108 CP9106 CP9102 124-1574 124-1374 124-1534 124-1334 CP8926 CP9163 124-1534 124-1334 CP8926 CP8991 CP8955 CP8924 122-5532 125-5532 125-6837 CP9074 CP9070 122-3832 122-5532 CP9074 CP9070 CP9074 123-3832 123-1236 (Continued) 540 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com GC Column Application and Method Guides Drinking Water EPA Method Application Recommended Column Part No. 515 DB-35ms, 30 m x 0.32 mm, 0.25 µm 123-3832 VF-1701ms, 30 m x 0.25 mm, 0.25 µm VF-5ms, 30 m x 0.25 mm, 0.25 µm CP9151 CP8944 VF-1701ms, 30 m x 0.25 mm, 0.25 µm VF-5ms, 30 m x 0.25 mm, 0.25 µm CP9151 CP8944 VF-5ms, 30 m x 0.25 mm, 1.00 µm CP8946 VF-624ms, 30 m x 0.53 mm, 3.00 µm VF-624ms, 75 m x 0.53 mm, 3.00 µm VF-5ms, 30 m x 0.32 mm, 1.00 µm DB-VRX, 60 m x 0.25 mm, 1.40 µm DB-624, 60 m x 0.25 mm, 1.4 µm HP-VOC, 60 m x 0.20 mm, 1.10 µm DB-VRX, 20 m x 0.18 mm, 1.00 µm DB-624, 20 m x 0.18 mm, 1.00 µm VF-5 Pesticides, 30 m x 0.25 mm, 0.25 µm HP-5ms, 30 m x 0.25 mm, 0.50 µm VF-5ms, 30 m x 0.25 mm, 0.25 µm CP9106 CP9108 CP8957 122-1564 122-1364 19091R-306 121-1524 121-1324 CP9074 19091S-133 CP8944 VF-5ms, 30 m x 0.25 mm, 0.25 µm CP8944 VF-5ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm DB-XLB, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.53 mm, 1.50 µm VF-5ms, 15 m x 0.25 mm, 0.25 µm CP8944 122-5532 122-1232 125-5532 CP8939 515.3 515.4 521 524.2 Determination of chlorinated herbicides in drinking water Determination of chlorinated acids in drinking water by liquid-liquid extraction, derivatization and GC with electron capture detection Determination of chlorinated acids in drinking water by liquid-liquid microextraction, derivatization, and fast GC with electron capture detection Determination of nitrosamines in drinking water by solid phase extraction and capillary column gas chromatography with large volume injection and chemical ionization tandem mass spectrometry (MS/MS) Measurement of purgeable organic compounds in water by capillary GC/MS 525, 525.2 Determination of organic compounds in drinking water by liquid-solid extraction and capillary column GC/MS 526 Determination of selected semivolatile organic compounds in drinking water by solid phase extraction and capillary column GC/MS Determination of selected pesticides and flame retardants in drinking water by solid phase extraction and capillary column GC/MS Determination of phenols in drinking water by solid phase extraction and capillary column GC/MS 527 528 529 Determination of explosives and related compounds in drinking water by solid phase extraction and capillary column GC/MS (Continued) AGILENT J&W GC AND GC/MS COLUMNS 541 GC Column Application and Method Guides Drinking Water EPA Method Application Recommended Column Part No. 551 VF-1301ms, 30 m x 0.25 mm, 1.00 µm DB-5ms, 30 m x 0.25 mm, 1.00 µm DB-1, 30 m x 0.25 mm, 1.00 µm CP9054 122-5533 122-1033 VF-1ms, 30 m x 0.25 mm, 1.00 µm VF-1301ms, 30 m x 0.25 mm, 1.00 µm DB-5ms, 30 m x 0.25 mm, 1.00 µm DB-1, 30 m x 0.25 mm, 1.00 µm Determination of Haloacetic Acids in Drinking Water by VF-5ms, 30 m x 0.25 mm, 0.25 µm Liquid-Liquid Extraction, Derivatization, and Gas DB-35ms, 30 m x 0.32 mm, 0.25 µm Chromatography with Electron Capture Detection DB-XLB, 30 m x 0.32 mm, 0.50 µm Determination of Haloacetic Acids and Dalapon in DB-35ms, 30 m x 0.32 mm, 0.25 µm Drinking Water by Ion Exchange Liquid-Solid Extraction DB-XLB, 30 m x 0.32 mm, 0.50 µm and Gas Chromatography with an Electron Capture Detector Determination of haloacetic acids and dalapon in VF-1701ms, 30 m x 0.25 mm, 0.25 µm drinking water by liquid-liquid extraction, derivatization VF-5ms, 30 m x 0.25 mm, 0.25 µm GC with electron capture detection DB-35ms, 30 m x 0.32 mm, 0.25 µm DB-XLB, 30 m x 0.32 mm, 0.50 µm Determination of haloacetic acids and dalapon in VF-1701ms, 30 m x 0.25 mm, 0.25 µm drinking water by liquid-liquid microextraction, VF-5ms, 30 m x 0.25 mm, 0.25 µm derivatization, and GC with electron capture detection Determination of carbonyl compounds in drinking water VF-1701ms, 30 m x 0.25 mm, 0.25 µm by pentafluorobenzylhydroxylamine derivatization and VF-5ms, 30 m x 0.25 mm, 0.25 µm capillary GC with electron capture detection CP8913 CP9054 122-5533 122-1033 CP8944 123-3832 123-1236 123-3832 123-1236 551.1 552 552.1 552.2 552.3 556 542 Determination of Chlorination Disinfection Byproducts and Chlorinated Solvents in Drinking Water by LiquidLiquid Extraction and Gas Chromatography with Electron Capture Detection Determination of chlorination disinfection byproducts, chlorinated solvents, and halogenated pesticides/herbicides in drinking water by liquid-liquid extraction and GC with electron-capture detection GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com CP9151 CP8944 123-3832 123-1236 CP9151 CP8944 CP9151 CP8944 GC Column Application and Method Guides Waste Water EPA Method Application Column Part No. 601 Purgeable Halocarbons 602 Purgeable aromatics 603 Acrolein and Acrylonitrile 604 Phenols 605 Benzidines 606 Phthalate esters 607 Nitrosamines 608 Organochlorine pesticides and PCBs VF-624ms, 75 m x 0.53 mm, 3.00 µm VF-624ms, 60 m x 0.32 mm, 1.80 µm VF-624ms, 30 m x 0.25 mm, 1.40 µm DB-VRX, 75 m x 0.45 mm, 2.55 µm DB-624, 75 m x 0.45 mm, 2.55 µm VF-624ms, 75 m x 0.53 mm, 3.00 µm VF-624ms, 30 m x 0.25 mm, 1.40 µm VF-624ms, 30 m x 0.25 mm, 1.40 µm DB-VRX, 30 m x 0.45 mm, 2.55 µm DB-624, 30 m x 0.45 mm, 2.55 µm VF-WAXms, 30 m x 0.25 mm, 1.00 µm VF-624ms, 30 m x 0.25 mm, 1.40 µm DB-VRX, 30 m x 0.45 mm, 2.55 µm DB-624, 30 m x 0.45 mm, 2.55 µm VF-624ms, 60 m x 0.32 mm, 1.80 µm VF-624ms, 60 m x 0.25 mm, 1.40 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm DB-XLB, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.53 mm, 1.50 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.53 mm, 1.50 µm DB-608, 30 m x 0.53 mm, 0.50 µm VF-5ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.53 mm, 1.50 µm DB-608, 30 m x 0.53 mm, 0.50 µm CP-Sil 8 CB for Amines, 30 m x 0.32 mm, 1.00 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.53 mm, 1.50 µm VF-5 Pesticides, 30 m x 0.25 mm, 0.25 µm VF-1701 Pesticides, 30 m x 0.25 mm, 0.25 µm VF-17ms, 30 m x 0.25 mm, 0.25 µm DB-35ms, 30 m x 0.32 mm, 0.25 µm DB-XLB, 30 m x 0.32 mm, 0.50 µm CP9108 CP9105 CP9102 124-1574 124-1374 CP9108 CP9102 CP9102 124-1534 124-1334 CP9206 CP9102 124-1534 124-1334 CP9105 CP9103 122-5532 122-1232 125-5532 122-5532 125-5532 125-6837 CP8944 122-5532 125-5532 125-6837 CP7596 122-5532 125-5532 CP9074 CP9070 CP8982 123-3832 123-1236 (Continued) AGILENT J&W GC AND GC/MS COLUMNS 543 GC Column Application and Method Guides Waste Water EPA Method Application Column Part No. 609 Nitroaromatics and Isophorone 610 Polynuclear Aromatic Hydrocarbons 611 Haloethers 612 Chlorinated Hydrocarbons 613 2,3,7,8-Tetrachlorodibenzo-p-dioxin 614 The Determination of Organophosphorus Pesticides in Municipal and Industrial Wastewater 615 Chlorinated herbicides 619 Triazine pesticides 622 The Determination of Organophosphorus Pesticides in Municipal and Industrial Wastewater VF-5ms, 30 m x 0.53 mm, 1.50 µm VF-5ms, 30 m x 0.25 mm, 0.50 µm HP-5ms, 30 m x 0.25 mm, 0.50 µm DB-5ms, 30 m x 0.53 mm, 1.50 µm DB-608, 30 m x 0.53 mm, 0.50 µm VF-17ms, 30 m x 0.25 mm, 0.25 µm VF-5ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.32 mm, 0.25 µm DB-1ms, 30 m x 0.25 mm, 0.25 µm VF-5ms, 30 m x 0.53 mm, 1.50 µm VF-5ms, 30 m x 0.25 mm, 0.50 µm VF-5ms, 30 m x 0.25 mm, 0.10 µm VF-35ms, 30 m x 0.25 mm, 0.25 µm VF-200ms, 30 m x 0.25 mm, 1.00 µm DB-5ms, 30 m x 0.32 mm, 0.50 µm HP-5ms, 30 m x 0.32 mm, 0.50 µm DB-1, 30 m x 0.32 mm, 0.50 µm CP-Sil 88 for Dioxins, 50 m x 0.25 mm, 0.20 µm VF-5ms, 60 m x 0.25 mm, 0.10 µm DB-35ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm VF-1701 Pesticides, 30 m x 0.25 mm, 0.25 µm VF-5 Pesticides, 30 m x 0.25 mm, 0.25 µm DB-35ms, 30 m x 0.32 mm, 0.25 µm VF-17ms, 30 m x 0.25 mm, 0.50 µm VF-5ms, 30 m x 0.25 mm, 0.25 µm DB-35ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm DB-35ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm CP8976 CP8945 19091S-133 125-5532 125-6837 CP8982 CP8944 122-5532 123-5532 122-0132 CP8976 CP8945 CP8943 CP8877 CP8860 123-5536 19091S-113 123-103E CP7588 CP8948 122-3832 122-5532 CP9070 CP9074 123-3832 CP8983 CP8944 122-3832 122-5532 122-3832 122-5532 (Continued) 544 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com GC Column Application and Method Guides Waste Water EPA Method Application Column Part No. 624 Purgeables 625 Base/neutrals and acids 1613 Tetra- through octa-chlorinated dioxins and furans by isotope dilution HRGC/HRMS 1624 1625 Volatile organic compounds by isotope dilution GC/MS Semivolatile organic compounds by isotope dilution GC/MS Volatile Halogenated Organic Compounds List by EPA Method 8021 VF-624ms, 75 m x 0.53 mm, 3.00 µm VF-624ms, 60 m x 0.32 mm, 1.80 µm VF-624ms, 30 m x 0.25 mm, 1.40 µm DB-VRX, 60 m x 0.25 mm, 1.40 µm DB-624, 60 m x 0.25 mm, 1.4 µm HP-VOC, 60 m x 0.20 mm, 1.10 µm DB-VRX, 20 m x 0.18 mm, 1.00 µm DB-624, 20 m x 0.18 mm, 1.00 µm VF-5 Pesticides, 30 m x 0.25 mm, 0.25 µm VF-1701 Pesticides, 30 m x 0.25 mm, 0.25 µm VF-200ms, 30 m x 0.25 mm, 0.25 µm HP-5ms, 30 m x 0.25 mm, 0.50 µm VF-5ms, 60 m x 0.25 mm, 0.25 µm CP-Sil 88 for Dioxins, 50 m x 0.25 mm, 0.20 µm VF-624ms, 60 m x 0.25 mm, 1.40 µm VF-5ms, 30 m x 0.25 mm, 0.25 µm CP9108 CP9105 CP9102 122-1564 122-1364 19091R-306 121-1524 121-1324 CP9074 CP9070 CP8858 19091S-133 CP8960 CP7588 CP9103 CP8944 DB-VRX, 75 m x 0.45 mm, 2.55 µm DB-624, 75 m x 0.45 mm, 2.55 µm DB-VRX, 75 m x 0.45 mm, 2.55 µm DB-624, 75 m x 0.45 mm, 2.55 µm 124-1574 124-1374 124-1574 124-1374 8010 8021 Volatile Halogenated & Aromatic Organic Compounds AGILENT J&W GC AND GC/MS COLUMNS 545 GC Column Application and Method Guides Solid Waste EPA Method Application Column Part No. 8010 Volatile Halogenated Organic Compounds List by EPA Method 8021 8011 1,2-Dibromoethane and 1,2-dibromo-3chloropropane by microextraction and GC 8015 Nonhalogenated organics by GC 8015c Nonhalogenated organics by GC 8020 Volatile Aromatic Organic Compounds List by EPA Method 8021 DB-VRX, 75 m x 0.45 mm, 2.55 µm DB-624, 75 m x 0.45 mm, 2.55 µm VF-1ms, 30 m x 0.32 mm, 0.25 µm DB-VRX, 30 m x 0.45 mm, 2.55 µm DB-624, 30 m x 0.45 mm, 2.55 µm DB-VRX, 30 m x 0.45 mm, 2.55 µm DB-624, 30 m x 0.45 mm, 2.55 µm VF-WAXms, 30 m x 0.53 mm, 1.00 µm CP-Sil 8 CB, 30 m x 0.53 mm, 1.50 µm DB-VRX, 30 m x 0.45 mm, 2.55 µm DB-624, 30 m x 0.45 mm, 2.55 µm DB-VRX, 75 m x 0.45 mm, 2.55 µm DB-624, 75 m x 0.45 mm, 2.55 µm VF-624ms, 60 m x 0.53 mm, 3.00 µm VF-624ms, 60 m x 0.25 mm, 1.40 µm CP-PoraBOND Q, 25 m x 0.53 mm, 10.00 µm DB-VRX, 30 m x 0.45 mm, 2.55 µm DB-624, 30 m x 0.45 mm, 2.55 µm CP-Wax 58 FFAP CB, 25 m x 0.53 mm, 2.00 µm VF-WAXms, 15 m x 0.53 mm, 1.00 µm 124-1574 124-1374 CP8924 124-1534 124-1334 124-1534 124-1334 CP9215 CP8736 124-1534 124-1334 124-1574 124-1374 CP9107 CP9103 CP7354 124-1534 124-1334 CP7654 CP9226 DB-5ms, 30 m x 0.25 mm, 0.25 µm DB-XLB, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.53 mm, 1.50 µm VF-5ms, 30 m x 0.53 mm, 1.50 µm VF-1701ms, 30 m x 0.53 mm, 1.00 µm VF-17ms, 30 m x 0.53 mm, 1.00 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.53 mm, 1.50 µm DB-608, 30 m x 0.53 mm, 0.50 µm 122-5532 122-1232 125-5532 CP8976 CP9171 CP9001 122-5532 125-5532 125-6837 8021, CLP Volamines Volatile Halogenated & Aromatic Organic Compounds 8021b Aromatic and halogenated volatiles by GC 8031 Acrylonitrile by GC 8032 8033 8040, 8041 Acrylamide by GC Acetonitrile by GC with nitrogen-phosphorus detection Phenols by Gas Chromatography 8041a Phenols by GC 8060 Phthalate esters (Continued) 546 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com GC Column Application and Method Guides Solid Waste EPA Method Application Column Part No. 8061 Phthalate esters by GC with electron capture detection (GC/ECD) 8070 Nitrosamines by Gas Chromatography 8070a Nitrosamines by GC 8081 Organochlorine pesticides by GC 8081a Organochlorine Pesticides by Gas Chromatography VF-5ms, 30 m x 0.53 mm, 1.50 µm VF-1701ms, 30 m x 0.53 mm, 1.00 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.53 mm, 1.50 µm DB-608, 30 m x 0.53 mm, 0.50 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.53 mm, 1.50 µm CP-Sil 8 CB for Amines, 30 m x 0.53 mm, 1.00 µm VF-17ms, 30 m x 0.53 mm, 1.50 µm VF-5ms, 30 m x 0.25 mm, 1.00 µm VF-35ms, 30 m x 0.25 mm, 1.00 µm VF-35ms, 30 m x 0.53 mm, 0.50 µm VF-1701ms, 30 m x 0.53 mm, 1.00 µm VF-5ms, 30 m x 0.53 mm, 1.50 µm DB-35ms, 30 m x 0.32 mm, 0.25 µm DB-XLB, 30 m x 0.32 mm, 0.50 µm DB-35ms, 30 m x 0.32 mm, 0.25 µm DB-XLB, 30 m x 0.32 mm, 0.50 µm VF-5ms, 30 m x 0.25 mm, 1.00 µm VF-35ms, 30 m x 0.25 mm, 1.00 µm VF-35ms, 30 m x 0.53 mm, 0.50 µm VF-1701ms, 30 m x 0.53 mm, 1.00 µm VF-5ms, 30 m x 0.53 mm, 1.50 µm HP-5ms, 30 m x 0.25 mm, 0.50 µm DB-5ms, 30 m x 0.53 mm, 1.50 µm DB-608, 30 m x 0.53 mm, 0.50 µm VF-5ms, 30 m x 0.53 mm, 1.50 µm VF-1701ms, 30 m x 0.53 mm, 1.00 µm VF-5ms, 15 m x 0.53 mm, 1.50 µm VF-1ms, 15 m x 0.53 mm, 1.50 µm VF-200ms, 15 m x 0.53 mm, 1.00 µm VF-5ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.32 mm, 0.25 µm DB-1ms, 30 m x 0.25 mm, 0.25 µm CP8976 CP9171 122-5532 125-5532 125-6837 122-5532 125-5532 CP7597 CP9002 CP8946 CP8879 CP8887 CP9171 CP8976 123-3832 123-1236 123-3832 123-1236 CP8946 CP8879 CP8887 CP9171 CP8976 19091S-133 125-5532 125-6837 CP8976 CP9171 CP8973 CP8967 CP8866 CP8944 122-5532 123-5532 122-0132 8082, CLP Pesticides Polychlorinated Biphenyls (PCBs) by Gas Chromatography 8082a Polychlorinated biphenyls (PCBs) by GC 8090 Nitroaromatics and Isophorone 8091 Nitroaromatics and cyclic ketones by GC 8095 Explosives by GC 8100 Polynuclear aromatic hydrocarbons (Continued) AGILENT J&W GC AND GC/MS COLUMNS 547 GC Column Application and Method Guides Solid Waste EPA Method Application Column Part No. 8111 Haloethers by GC 8120 Chlorinated hydrocarbons by Gas Chromatography 8121 Chlorinated hydrocarbons by GC: capillary column technique 8131 Aniline and selected derivatives by GC 8140 Organophosphorus Pesticides by GC-NPD 8141a Organophosphorus compounds by gas chromatography: capillary column technique 8141b Organophosphorus compounds by GC 8150 8151 Chlorinated herbicides Chlorinated herbicides by GC using methylation or pentafluorobenzylation derivatization: capillary column technique Chlorinated herbicides by GC using methylation or pentafluorobenzylation derivatization VF-5ms, 15 m x 0.53 mm, 1.50 µm VF-1701ms, 30 m x 0.53 mm, 1.00 µm DB-5ms, 30 m x 0.32 mm, 0.50 µm HP-5ms, 30 m x 0.32 mm, 0.50 µm DB-1, 30 m x 0.32 mm, 0.50 µm VF-200ms, 30 m x 0.53 mm, 1.00 µm VF-WAXms, 30 m x 0.53 mm, 1.00 µm VF-5ms, 30 m x 0.53 mm, 1.50 µm VF-1701ms, 30 m x 0.53 mm, 1.00 µm DB-5ms, 30 m x 0.32 mm, 0.50 µm HP-5ms, 30 m x 0.32 mm, 0.50 µm DB-1, 30 m x 0.32 mm, 0.50 µm VF-5ms, 30 m x 0.25 mm, 0.25 µm CP-Sil 8 CB for Amines, 30 m x 0.25 mm, 0.25 µm DB-35ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm DB-35ms, 30 m x 0.25 mm, 0.25 µm DB-5ms, 30 m x 0.25 mm, 0.25 µm VF-200ms, 30 m x 0.53 mm, 1.00 µm VF-35ms, 30 m x 0.53 mm, 1.00 µm VF-5ms, 30 m x 0.53 mm, 1.00 µm VF-1ms, 30 m x 0.53 mm, 1.00 µm DB-35ms, 30 m x 0.32 mm, 0.25 µm DB-35ms, 30 m x 0.32 mm, 0.25 µm CP8973 CP9171 123-5536 19091S-113 123-103E CP8868 CP9215 CP8976 CP9171 123-5536 19091S-113 123-103E CP8944 CP7598 122-3832 122-5532 122-3832 122-5532 CP8868 CP8888 CP8975 CP8969 123-3832 123-3832 VF-5 Pesticides, 30 m x 0.25 mm, 0.25 µm VF-5ms, 30 m x 0.32 mm, 1.00 µm VF-35ms, 30 m x 0.25 mm, 0.25 µm VF-1701 Pesticides, 30 m x 0.25 mm, 0.25 µm VF-35ms, 30 m x 0.53 mm, 1.00 µm VF-1701ms, 30 m x 0.53 mm, 1.00 µm DB-VRX, 20 m x 0.18 mm, 1.00 µm DB-624, 20 m x 0.18 mm, 1.00 µm DB-VRX, 60 m x 0.25 mm, 1.40 µm DB-624, 60 m x 0.25 mm, 1.4 µm HP-VOC, 60 m x 0.20 mm, 1.10 µm CP9074 CP8957 CP8877 CP9070 CP8888 CP9171 121-1524 121-1324 122-1564 122-1364 19091R-306 8151b 8240 Volatile Chlorinated and Aromatic Hydrocarbons (Continued) 548 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com GC Column Application and Method Guides Solid Waste EPA Method Application Column Part No. 8260/CLP-VOCs Volatile Organic Compounds by Gas Chromatography/Mass Spectroscopy (GC/MS): Capillary Column Technique Method 8260b Volatile organic compounds by GC/MS 8261 Volatile organic compounds by vacuum distillation in combination with GC/MS spectrometry (VD/GC/MS) Semivolatile Organic Compounds by Gas Chromatography/Mass Spectrometry (GC/MS) Semivolatile organic compounds by GC/MS DB-VRX, 60 m x 0.25 mm, 1.40 µm DB-624, 60 m x 0.25 mm, 1.4 µm HP-VOC, 60 m x 0.20 mm, 1.10 µm DB-VRX, 20 m x 0.18 mm, 1.00 µm DB-624, 20 m x 0.18 mm, 1.00 µm VF-624ms, 75 m x 0.53 mm, 3.00 µm VF-5ms, 30 m x 0.25 mm, 1.00 µm VF-624ms, 60 m x 0.32 mm, 1.80 µm VF-624ms, 60 m x 0.53 mm, 3.00 µm VF-624ms, 60 m x 0.25 mm, 1.40 µm 122-1564 122-1364 19091R-306 121-1524 121-1324 CP9108 CP8946 CP9105 CP9107 CP9103 HP-5ms, 30 m x 0.25 mm, 0.50 µm 19091S-133 8270 8270d 8275a 8280b 8290b 8410 8430 VF-5ms, 30 m x 0.25 mm, 0.25 µm VF-5ms, 30 m x 0.25 mm, 0.50 µm VF-5ms, 30 m x 0.25 mm, 1.00 µm Semivolatile organic compounds (PAHs and PCBs) VF-5ms, 30 m x 0.25 mm, 0.25 µm in soils/sludges and solid wastes using thermal VF-5ms, 30 m x 0.25 mm, 0.50 µm extraction/gas chromatography/mass spectrometry VF-5ms, 30 m x 0.25 mm, 1.00 µm (TE/GC/MS) Polychlorinated dibenzo-p-dioxins (PCDDs) and CP-Sil 8 CB, 30 m x 0.25 mm, 0.25 µm polychlorinated dibenzofurans (PCDfs) by high resolution gas chromatography/low resolution mass spectrometry (HRGC/LRMS) Polychlorinated dibenzo-p-dioxins (PCDDs) and CP-Sil 8 CB, 30 m x 0.25 mm, 0.25 µm polychlorinated dibenzofurans (PCDfs) by high CP-Sil 88 for Dioxins, 50 m x 0.25 mm, 0.20 µm resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) Gas chromatography/Fourier transform infrared VF-5ms, 30 m x 0.32 mm, 0.25 µm (GC/FT-IR) spectrometry for semivolatile organics: capillary column Analysis of bis(2-chloroethyl) ether and hydrolysis VF-WAXms, 30 m x 0.53 mm, 1.00 µm products by direct aqueous injection (GC/FT-IR) CP8944 CP8945 CP8946 CP8944 CP8945 CP8946 CP8751 CP8751 CP7588 CP8955 CP9215 AGILENT J&W GC AND GC/MS COLUMNS 549 GC Column Application and Method Guides United States Pharmacopoeia (USP) GC Phases USP Phase Composition G1 Dimethylpolysiloxane oil G2 Dimethylpolysiloxane gum G3 50% Phenyl 50% methylpolysiloxane G5 G6 G7 G8 G14 G15 G16 G17 3-cyanopropyl polysiloxane Trifluoropropylmethylpolysilicone 50% 3-cyanopropyl 50% phenylmethylsilicone 80% Bis(3-cyanopropyl) 20% 3-cyanopropylphenylpolysiloxane or 90% 3-cyanopropyl 10% phenylmethylsiloxane Polyethylene glycol (average molecular weight of 950-1,050) Polyethylene glycol (average molecular weight of 3,000-3,700) Polyethylene glycol (average molecular weight of 15,000) 75% Phenyl 25% methylpolysiloxane G19 G20 G25 G27 25% Phenyl 25% cyanopropylmethylsilicone Polyethylene glycol (average molecular weight of 380-420) Polyethylene glycol TPA (Carbowax 20M terephthalic acid) 5% Phenyl 95% methylpolysiloxane G28 G32 G35 G36 25% Phenyl 75% methylpolysiloxane 20% Phenylmethyl 80% dimethylpolysiloxane Polyethylene glycol & diepoxide esterified with nitroterepthalic acid 1% Vinyl 5% phenylmethylpolysiloxane G38 Phase G1 plus a tailing inhibitor G39 Polyethylene glycol (average molecular weight of 1,500) G41 Phenylmethyldimethylsilicone (10% phenyl substituted) G42 35% Phenyl 65% dimethylvinylsiloxane G43 6% Cyanopropylphenyl 94% dimethylpolysiloxane G45 Divinylbenzene-ethylene glycol-dimethacrylate G46 14% Cyanopropylphenyl 86% methylpolysiloxane Agilent Phase Recommendation HP-1*, DB-1*, HP-1ms*, DB-1ms*, VF-1ms, CP-Sil 5 CB, CP-Sil 5 CB Low Bleed/MS HP-1*, DB-1*, HP-1ms*, DB-1ms*, VF-1ms, CP-Sil 5 CB, CP-Sil 5 CB Low Bleed/MS, CP-SimDist DB-17*, HP-50+*, VF-17ms, CP-Sil 24 CB, CP-Sil 24 CB Low Bleed/MS DB-23, VF-23ms, Select for FAME, CP-Sil 88 DB-200, DB-210, VF-200ms DB-225, DB-225ms, CP-Sil 43 CB HP-88, VF-23ms DB-WAX, VF-WAXms, CP-Wax 52 CB DB-WAX, VF-WAXms, CP-Wax 52 CB DB-WAX*, VF-WAXms, CP-Wax 52 CB DB-17, HP-50+, VF-17ms, CP-Sil 24 CB, CP-Sil 24 CB Low Bleed/MS DB-225*, DB-225ms, CP-Sil 43 CB DB-WAX, VF-WAXms, CP-Wax 52 CB DB-FFAP*, HP-FFAP*, CP-Wax 58 (FFAP) CB, CP-FFAP CB DB-5*, HP-5*, HP-5ms*, DB-5ms, VF-5ms, VF-5ht, CP-Sil 8 CB, CP-Sil 8 CB Low Bleed/MS DB-35, HP-35, DB-35ms, VF-35ms DB-35, HP-35, DB-35ms, VF-35ms DB-FFAP*, HP-FFAP*, CP-Wax 58 (FFAP) CB, CP-FFAP CB DB-5, HP-5, HP-5ms, DB-5ms, VF-5ms, VF-5ht, CP-Sil 8 CB, CP-Sil 8 CB Low Bleed/MS DB-1, HP-1, HP-1ms, DB-1ms, VF-1ms, CP-Sil 5 CB, CP-Sil 5 CB Low Bleed/MS DB-WAX, VF-WAXms, CP-Wax 52 CB DB-5, HP-5, HP-5ms, DB-5ms, VF-5ms, VF-5ht, CP-Sil 8 CB, CP-Sil 8 CB Low Bleed/MS DB-35*, HP-35*, DB-35ms, VF-35ms DB-624*, DB-1301, VF-624ms, VF-1301ms, CP-1301, CP-Select 624 CB HP-PLOT U*, CP-PoraBOND U, CP-PoraPLOT U DB-1701*, VF-1701ms, CP-Sil 19 CB, CP-Sil 19 CB Low Bleed/MS *Indicates an exact equivalent Tips & Tools Gain extra confidence to meet high standards with Agilent's solution for the revised USP <467>. Visit www.agilent.com/chem/usp467an 550 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com GC Column Application and Method Guides ASTM Methods Method Title Recommended Agilent Column Part No. D 1945 Standard Test Method for the Analysis of Natural Gas by GC D 1946 Standard Test Method for the Analysis of Reformed Gas by GC D 1983 Standard Test Method for Fatty Acid Composition by Gas-Liquid Chromatography of Methyl Esters Standard Test Method for the Analysis of Liquified Petroleum (LP) Gases and Propene Concentrates by GC Standard Test Methods for Pentaerythritol Standard Test Method for Analysis of High-Purity n-Heptane and Isooctane by Capillary GC Standard Test Method for C8 Aromatic Hydrocarbons by GC Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by GC Standard Test Method for Butadiene Dimer and Styrene in Butadiene Concentrates by GC HP PLOT, 15 m x 0.53 mm, 50 µm HP PLOT Q, 15 m x 0.53 mm, 40 µm CP-Molsieve 5Å, 10 m x 0.53 mm, 50.00 µm CP-PoraPLOT Q-HT, 10 m x 0.53 mm, 20.00 µm HP PLOT, 15 m x 0.53 mm, 50 µm HP PLOT Q, 15 m x 0.53 mm, 40 µm CP-Molsieve 5Å, 10 m x 0.53 mm, 50.00 µm CP-Molsieve 5Å, 25 m x 0.25 mm, 30.00 µm DB-WAX, 30 m x 0.25 mm, 0.25 µm 19095P-MS9 19095P-QO3 CP7537 CP7558 19095P-MS9 19095P-QO3 CP7537 CP7533 122-7032 HP PLOT Al2O3 "KCl", 30 m x 0.53 mm, 15 µm HP PLOT Al2O3 "S", 30 m x 0.53 mm, 15 µm 19095P-K23 19095P-S23 CP-Sil 5 CB, 30 m x 0.53 mm, 1.50 µm DB-1, 60 m x 0.25 mm, 0.50 µm CP8735 122-106E HP-INNOWax, 60 m x 0.25 mm, 0.25 µm 19091N-136 HP-INNOWax, 60 m x 0.32 mm, 0.25 µm 19091N-116 DB-1, 30 m x 0.53 mm, 5.00 µm CP-Sil 5 CB, 30 m x 0.53 mm, 1.50 µm DB-1, 30 m x 0.53 mm, 5.00 µm GS-Alumina, 30 m x 0.53 mm, CP-Al2O3/KCl, 50 m x 0.53 mm, 10.00 µm CP-Sil 88 for FAME, 50 m x 0.25 mm, 0.20 µm 125-1035 CP8735 125-1035 115-3532 CP7518 CP7488 HP PLOT, 30 m x 0.53 mm, 50 µm CP-CarboBOND, 25 m x 0.53 mm, 10.00 µm GS-GasPro, 60 m x 0.32 mm, 19095P-MS0 CP7374 113-4362 CP-Sil 8 CB, 25 m x 0.32 mm, 0.40 µm CP-FFAP CB, 25 m x 0.53 mm, 1.00 µm CP5850 CP7486 D 2163 D 2195 D 2268 D 2306 D 2360 D 2426 D 2427 Standard Test Method for Determination of C2 through C5 Hydrocarbons in Gasoline by GC D 2245 Standard Test Method for Identification of Oils and Oil Acids in Solvent-Reducible Paints Standard Test Method for Noncondensable Gases in C2 and Lighter Hydrocarbon Products by GC D 2504 D 2505 D 2580 Standard Test Method for Ethylene, Other Hydrocarbons, and Carbon Dioxide in High-Purity Ethylene by GC Standard Test Method for Phenols in Water by Gas-Liquid Chromatography (Continued) AGILENT J&W GC AND GC/MS COLUMNS 551 GC Column Application and Method Guides ASTM Methods Method Title Recommended Agilent Column Part No. D 2593 Standard Test Method for Butadiene Purity and Hydrocarbon Impurities by GC D 2712 Standard Test Method for for Hydrocarbon Traces in Propylene Concentrates by GC Standard Practices for Uniformity of Traffic Paint Vehicle Solids by Spectroscopy and Gas Chromatography Standard Test Method for Purity of Methyl Ethyl Ketone by GC GS-Alumina, 30 m x 0.53 mm CP-Al2O3/KCl, 25 m x 0.32 mm, 5.00 µm CP-Al2O3/KCl, 50 m x 0.53 mm, 10.00 µm GS-Alumina, 50 m x 0.53 mm 115-3532 CP7515 CP7518 115-3552 CP-Sil 88 for FAME, 50 m x 0.25 mm, 0.20 µm CP7488 DB-WAX, 30 m x 0.53 mm, 1.00 µm DB-210, 15 m x 0.53 mm, 1 µm CP-WAX 52 CB, 30 m x 0.32 mm, 0.50 µm CP-WAX 52 CB, 30 m x 0.53 mm, 1.00 µm DB-2887, 10 m x 0.53 mm, 3.00 µm CP-SimDist UltiMetal, 5 m x 0.53 mm, 0.88 µm CP-SimDist UltiMetal, 10 m x 0.53 mm, 2.65 µm CP-SimDist UltiMetal, 5 m x 0.53 mm, 0.17 µm HP-1, 10 m x 0.53 mm, 0.88 µm HP-1, 5 m x 0.53 mm, 0.88 µm CP-Select 624 CB, 30 m x 0.32 mm, 1.80 µm CP-Select 624 CB, 75 m x 0.53 mm, 3.00 µm CP-WAX 52 CB, 30 m x 0.32 mm, 0.50 µm CP-WAX 52 CB, 30 m x 0.53 mm, 1.00 µm DB-1, 60 m x 0.32 mm, 0.50 µm 125-7032 125-0212 CP8763 CP8738 125-2814 CP7570 CP7582 CP7532 19095Z-021 19095Z-020 CP7414 CP7417 CP8763 CP8738 123-106E CP-Sil 5 CB, 30 m x 0.32 mm, 1.00 µm CP-Sil 5 CB, 30 m x 0.53 mm, 1.50 µm DB-624, 30 m x 0.53 mm, 3.00 µm CP8760 CP8735 125-1334 CP-PoraPLOT Q, 25 m x 0.53 mm, 20.00 µm CP-WAX 52 CB, 30 m x 0.53 mm, 1.00 µm CP7554 CP8738 CP-Sil 5 CB, 30 m x 0.32 mm, 3.00 µm CP-Sil 5 CB, 30 m x 0.53 mm, 3.00 µm DB-WAX, 30 m x 0.53 mm, 1.00 µm DB-624, 30 m x 0.45 mm, 2.55 µm CP-WAX 52 CB, 60 m x 0.53 mm, 1.00 µm HP-1ms, 30 m x 0.32 mm, 1.00 µm CP8687 CP8677 125-7032 124-1334 CP8798 19091S-713 D 2743 D 2804 D 2887 Standard Test Method for Boiling Range Distribution of Petroleum Fractions by GC Extended D 2887 Standard Test Method for Boiling Range Distribution of Petroleum Fractions by GC, to C60 D 2908 Standard Practice for Measuring Volatile Organic Matter in Water by Aqueous-Injection GC D 3054 Standard Test Method for Analysis of Cyclohexane by GC Standard Practice for Qualitative Identification of Polymers in Emulsion Paints D 3168 D 3257 D 3271 D 3328 Standard Test Method for Aromatics in Mineral Spirits by GC Standard Practice for Direct Injection of Solvent-Reducible Paints into a Gas Chromatograph for Solvent Analysis Standard Test Methods for Comparison of Waterborne Petroleum Oils by Gas Chromatography D 3329 Standard Test Method for Purity of Methyl Isobutyl Ketone by GC D 3432 Standard Test Method for Unreacted Toluene Diisocyanates in Urethane Prepolymers and Coating Solutions by GC (Continued) 552 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com GC Column Application and Method Guides ASTM Methods Method Title Recommended Agilent Column Part No. D 3447 Standard Test Method for Purity of Halogentated Organic Solvents Standard Practice for Rubber – Identification by Pyrolysis-Gas Chromatography Standard Test Method for Purity of Monomeric Plasticizers by Gas Chromatography DB-624, 30 m x 0.53 mm, 3.00 µm 125-1334 CP-Sil 5 CB, 30 m x 0.53 mm, 1.50 µm CP8735 D 3452 D 3465 D 3524 D 3545 D 3606 D 3687 D 3695 D 3710 D 3749 D 3760 D 3792 D 3797 D 3798 D 3871 D 3876 CP-Sil 5 CB, 25 m x 0.32 mm, 0.52 µm CP-Sil 5 CB, 30 m x 0.53 mm, 1.50 µm Standard Test Method for Diesel Fuel Diluent in Used CP-SimDist UltiMetal, 10 m x 0.53 mm, 0.53 µm Diesel Engine Oils by Gas Chromatography Standard Test Method for Alcohol Content and Purity DB-624, 30 m x 0.53 mm, 3.00 µm of Acetate Esters by GC Standard Test Method for Determination of Benzene VF-1ms, 15 m x 0.25 mm, 0.10 µm and Toluene in Finished Motor and Aviation Gasoline CP-TCEP for Alcohols in Gasoline, 50 m x 0.25 mm, by Gas Chromatography 0.40 µm Standard Test Method for Analysis of Organic Vapors DB-WAX, 30 m x 0.53 mm, 1.00 µm Collected by the Activated Charcoal Tube Adsorption DB-WAX, 30 m x 0.45 mm, 0.85 µm Method CP-WAX 52 CB, 30 m x 0.32 mm, 0.50 µm CP-WAX 52 CB, 30 m x 0.53 mm, 1.00 µm Standard Test Method for Volatile Alcohols in Water DB-WAX, 30 m x 0.53 mm, 1.00 µm by Direct Aqueous-Injection GC CP-SimDist UltiMetal, 10 m x 0.53 mm, 0.53 µm Standard Test Method for Boiling Range Distribution DB-2887, 10 m x 0.53 mm, 3.00 µm of Gasoline and Gasoline Fractions by GC Standard Test Method for Residual Vinyl Chloride CP-PoraBOND Q, 10 m x 0.32 mm, 5.00 µm Monomer in Poly(Vinyl Chloride) Resins by Gas CP-PoraBOND Q, 10 m x 0.53 mm, 10.00 µm Chromatographic Headspace Technique Standard Test Method for Analysis of DB-WAX, 60 m x 0.32 mm, 0.25 µm Isopropylbenzene (Cumene) by GC HP-1, 50 m x 0.32 mm, 0.52 µm CP-Xylenes, 50 m x 0.53 mm, Standard Test Method for Water Content of Coatings CP-PoraBOND Q, 25 m x 0.32 mm, 5.00 µm by Direct Injection Into a Gas Chromatograph CP-PoraBOND Q, 25 m x 0.53 mm, 10.00 µm Standard Test Method for Analysis of o-Xylene by GC HP-INNOWax, 60 m x 0.32 mm, 0.50 µm CP-Xylenes, 50 m x 0.53 mm Standard Test Method for Analysis of p-Xylene by GC HP-INNOWax, 60 m x 0.32 mm, 0.50 µm CP-Xylenes, 50 m x 0.53 mm Standard Test Method for Purgeable Organic DB-VRX, 75 m x 0.45 mm, 2.55 µm Compounds in Water Using Headspace Sampling Standard Test Method for Methoxyl and CP-Sil 5 CB, 30 m x 0.32 mm, 1.00 µm Hydroxypropyl Substitution in Cellulose Ether CP-Sil 5 CB, 30 m x 0.53 mm, 1.50 µm Products by Gas Chromatography CP8430 CP8735 CP7592 125-1334 CP8906 CP7525 125-7032 124-7032 CP8763 CP8738 125-7032 CP7592 125-2814 CP7350 CP7353 123-7062 19091Z-115 CP7428 CP7351 CP7354 19091N-216 CP7428 19091N-216 CP7428 124-1574 CP8760 CP8735 (Continued) AGILENT J&W GC AND GC/MS COLUMNS 553 GC Column Application and Method Guides ASTM Methods Method Title Recommended Agilent Column Part No. D 3893 Standard Test Method for Purity of Methyl Amyl Ketone and Methyl Isoamyl Ketone by GC Standard Test Method for Low-Molecular Weight Halogenated Hydrocarbons in Water Standard Test Method for Analysis of Polychlorinated Biphenyls in Insulating Liquids by Gas Chromatography Standard Test Method for Determination of Butylated Hydroxy Toluene (BHT) in Polymers of Ethylene and Ethylene – Vinyl Acetate (EVA) Copolymers By Gas Chromatography Standard Test Method for Residual Acrylonitrile Monomer Styrene-Acrylonitrile Copolymers and Nitrile Rubber by Headspace Gas Chromatography Standard Test Method for Benzene in Hydrocarbon Solvents by Gas Chromatography DB-VRX, 30 m x 0.45 mm, 2.55 µm 124-1534 DB-VRX, 30 m x 0.45 mm, 2.55 µm 124-1534 CP-Sil 8 CB for PCB, 50 m x 0.25 mm, 0.25 µm CP7482 CP-Sil 5 CB, 30 m x 0.32 mm, 3.00 µm CP-Sil 5 CB, 30 m x 0.53 mm, 3.00 µm CP8687 CP8677 CP-PoraBOND Q, 25 m x 0.53 mm, 10.00 µm CP7354 VF-1ms, 15 m x 0.25 mm, 0.10 µm CP-TCEP for Alcohols in Gasoline, 50 m x 0.25 mm, 0.40 µm DB-FFAP, 30 m x 0.32 mm, 0.25 µm CP8906 CP7525 HP PLOT Al2O3 S, 50 m x 0.53 mm, 15 µm CP-Al2O3/Na2SO4, 25 m x 0.53 mm, 10.00 µm DB-VRX, 30 m x 0.45 mm, 2.55 µm 19095P-S25 CP7567 124-1534 CP-TCEP for Alcohols in Gasoline, 50 m x 0.25 mm, 0.40 µm CP-PoraBOND Q, 25 m x 0.32 mm, 5.00 µm CP-PoraBOND Q, 25 m x 0.53 mm, 10.00 µm CP7525 CP-TCEP for Alcohols in Gasoline, 50 m x 0.25 mm, 0.40 µm DB-FFAP, 30 m x 0.45 mm, 0.85 µm CP-Wax 58 FFAP CB, 25 m x 0.53 mm, 1.00 µm CP-Wax 58 FFAP CB, 25 m x 0.53 mm, 1.00 µm CP7525 124-3232 CP7614 CP7614 DB-WAX, 30 m x 0.45 mm, 0.85 µm 124-7032 D 3973 D 4059 D 4275 D 4322 D 4367 D 4415 D 4424 D 4443 D 4492 D 4509 D 4534 D 4735 D 4768 D 4864 Standard Test Method for Determination of Dimer in Acrylic Acid Standard Test Method for Butylene Analysis by GC Standard Test Method for Residual Vinyl Chloride Monomer Content in PPB Range in Vinyl Chloride Homo- and Co-Polymers by Headspace GC Standard Test Method for Analysis of Benzene by Gas Chromatography Standard Test Methods for Determining the 24-Hour Gas (AIR) Space Acetaldehyde Content of Freshly Blown PET Bottles Test Method for Benzene Content of Cyclic Products by Gas Chromatography Standard Test Method for Determination of Trace Thiophene in Refined Benzene by GC Standard Test Method for Analysis of 2,6-DitertiaryButyl Para-Cresol and 2,6-Ditertiary- Butyl Phenol in Insulating Liquids by Gas Chromatography Standard Test Method for Determination of Traces of Methanol in Propylene Concentrates by GC 123-3232 CP7351 CP7354 (Continued) 554 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com GC Column Application and Method Guides ASTM Methods Method Title Recommended Agilent Column Part No. D 4947 Standard Test Method for Chlordane and Heptachlor Residues in Indoor Air D 4961 Standard Test Method for GC Analysis of Major Organic Impurities in Phenol Produced by the Cumene Process Standard Test Method for Cyclohexylamine Morpholine and Diethylaminoethanol in Water and Condensed Steam by Direct Aqueous Injection GC Standard Test Method for Ethyl Methyl Pentonal Content and Purity Value of 2-Ethylhexanol by GC DB-5, 30 m x 0.53 mm, 1.50 µm DB-608, 30 m x 0.53 mm, 0.83 µm DB-FFAP, 30 m x 0.45 mm, 0.85 µm HP PLOT Q, 15 m x 0.53 mm, 40 µm 125-5032 125-1730 124-3232 19095P-QO3 HP-5ms, 30 m x 0.32 mm, 1.00 µm CAM, 30 m x 0.53 mm, 1 µm 19091S-213 115-2132 HP-1, 15 m x 0.53 mm, 5.00 µm HP-INNOWax, 30 m x 0.32 mm, 0.25 µm HP-INNOWax, 60 m x 0.32 mm, 0.50 µm CP-WAX 52 CB, 60 m x 0.32 mm, 0.50 µm DB-5, 30 m x 0.53 mm, 1.50 µm DB-5, 30 m x 0.32 mm, 1.00 µm HP-PONA, 50 m x 0.20 mm, 0.50 µm CP-Sil PONA for ASTM D 5134, 50 m x 0.21 mm, 0.50 µm HP-INNOWax, 60 m x 0.32 mm, 0.50 µm CP-WAX 52 CB, 60 m x 0.32 mm, 0.50 µm DB-1, 30 m x 0.32 mm, 1.00 µm DB-608, 30 m x 0.32 mm, 0.5 µm DB-XLB, 30 m x 0.25 mm, 0.25 µm GS-GasPro, 30 m x 0.32 mm HP PLOT Q, 30 m x 0.53 mm, 40 µm HP-1, 7.5 m x 0.53 mm, 5.00 µm 19095Z-621 19091N-113 19091N-216 CP8773 125-5032 123-5033 19091S-001 CP7531 HP-5ms, 30 m x 0.25 mm, 0.25 µm DB-225ms, 30 m x 0.25 mm, 0.25 µm HP-1ms, 30 m x 0.32 mm, 1.00 µm DB-624, 30 m x 0.45 mm, 2.55 µm 19091S-433 122-2932 19091S-713 124-1334 HP-5ms, 30 m x 0.25 mm, 0.25 µm DB-1701P, 30 m x 0.25 mm, 0.25 µm DB-XLB, 30 m x 0.25 mm, 0.25 µm DB-35ms, 30 m x 0.25 mm, 0.25 µm 19091S-433 122-7732 122-1232 122-3832 D 4983 D 5008 D 5060 Standard Test Method for Determining Impurities in High-Purity Ethylbenzene by GC D 5075 Standard Test Method for Nicotine in Indoor Air D 5134 Standard Test Method for Detailed Analysis of Petroleum Naphthas Through n-Nonane by Capillary GC D 5135 Standard Test Method for Analysis of Styrene by Capillary GC D 5175 Standard Test Method for Organohalide Pesticides and Polychlorinated Biphenyls in Water by Microextraction and GC D 5303 Standard Test Method for Trace Carbonyl Sulfide in Propylene by GC D 5307 Standard Test Method for Determination of Boiling Range Distribution of Crude Petroleum by GC Standard Test Method for Tar Acid Composition by Capillary GC D 5310 D 5316 D 5317 Standard Test Method for 1, 2-Dibromoethane and 1, 2-Dibromo-3-Chloropropane in Water by Microextraction and GC Standard Test Method for Determination of Chlorinated Organic Acid Compounds in Water by GC with Electron Capture Detector 19091N-216 CP8773 123-1033 123-1730 122-1232 113-4332 19095P-QO4 19095Z-627 (Continued) AGILENT J&W GC AND GC/MS COLUMNS 555 GC Column Application and Method Guides ASTM Methods Method Title Recommended Agilent Column Part No. D 5320 Standard Test Method for Determination of 1, 1-Trichloroethane and Methylene Chloride in Stabilized Trichloroethylene and Tetrachloroethylene Standard Test Method for Boiling Point Distribution of Hydrocarbon Solvents by GC Standard Test Method for Analysis of Methyl Tert-Butyl Ether (MTBD) by GC DB-1, 30 m x 0.53 mm, 3.00 µm DB-VRX, 30 m x 0.32 mm, 1.80 µm 125-1034 123-1534 DB-2887, 10 m x 0.53 mm, 3.00 µm 125-2814 HP-PONA, 50 m x 0.20 mm, 0.50 µm DB-Petro, 100 m x 0.25 mm, 0.50 µm DB-1, 25 m x 0.32 mm, 0.25 µm DB-5, 15 m x 0.25 mm, 0.25 µm HP-5ms, 30 m x 0.25 mm, 0.25 µm DB-1701P, 30 m x 0.25 mm, 0.25 µm DB-XLB, 30 m x 0.25 mm, 0.25 µm DB-35ms, 30 m x 0.25 mm, 0.25 µm DB-PS1, 15 m x 0.53 mm, 0.15 µm HP-1, 100 m x 0.25 mm, 0.50 µm 19091S-001 122-10A6 123-1022 122-5012 19091S-433 122-7732 122-1232 122-3832 145-1011 19091Z-530 CP-Sil 5 CB for Sulfur, 30 m x 0.32 mm, 4.00 µm CP7529 HP PLOT Q, 15 m x 0.53 mm, 40 µm HP PLOT U, 30 m x 0.53 mm, 20 µm 19095P-QO3 19095P-UO4 HP PLOT Q, 30 m x 0.53 mm, 40 µm 19095P-QO4 DB-1, 30 m x 0.53 mm, 5.00 µm CP-TCEP for Alcohols in Gasoline, 50 m x 0.25 mm, 0.40 µm CP-Sil 5 CB, 30 m x 0.53 mm, 5.00 µm VF-1ms, 15 m x 0.25 mm, 0.10 µm DB-5, 30 m x 0.25 mm, 0.25 µm 125-1035 CP7525 D 5399 D 5441 D 5442 Standard Test Method for Analysis of Petroleum Waxes by GC D 5475 Standard Test Method for Nitrogen- and Phosphorus-Containing Pesticides in Water by GC with a Nitrogen Phosphorus Detector D 5480 D 5501 Standard Test Method for Engine Oil Volatility by GC Standard Test Method for Determination of Ethanol Content of Denatured Fuel Ethanol by GC Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence Standard Test Method for Determination of Trace Organic Impurities in Monomer Grade Vinyl Chloride by Capillary Column/Multi-dimensional GC Standard Test Method for Determination of Residual Acrylonitrile Monomer in Styrene-Acyrlonitrile Co-polymer Resins and Nitrile-Butadiene Rubber by Headspace Capillary GC Standard Test Method for Determination of Benzene, Toluene, Ethylbenzene, p/m-Xylene, C9 and Heavier Aromatics, and Total Aromatics in Finished Gasoline by GC D 5504 D 5507 D 5508 D 5580 D 5599 Standard Test Method for Determination of Oxygenates in Gasoline by GC and Oxygen Selective Flame Ionization Detection CP8775 CP8906 122-5032 (Continued) 556 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com GC Column Application and Method Guides ASTM Methods Method Title Recommended Agilent Column Part No. D 5623 Standard Test Method for Sulfur Compounds in Light Petroleum Liquids by GC and Sulfur Selective Detection Standard Test Method for Analysis of High Purity Benzene for Cyclohexane Feedstock by Capillary GC Standard Practice for Oil Spill Source Identification by GC and Positive Ion Electron Impact Low Resolution Mass Spectrometry Standard Test Method for Determination of Benzene, Toluene, and Total Aromatics in Finished Gasoline by GC/MS Standard Test Method for Measurement of Purgeable Organic Compounds in Water by Capillary Column GC/MS HP-1, 30 m x 0.32 mm, 4.00 µm 19091Z-613 DB-Petro, 50 m x 0.20 mm, 0.5 µm 122-10A6E DB-5, 30 m x 0.25 mm, 0.25 µm DB-TPH, 30 m x 0.32 mm, 0.25 µm 122-5032 123-1632 HP-1, 60 m x 0.25 mm, 1.00 µm 19091Z-236 DB-VRX, 60 m x 0.25 mm, 1.40 µm DB-VRX, 20 m x 0.18 mm, 1.00 µm DB-624, 60 m x 0.25 mm, 1.4 µm DB-624, 20 m x 0.18 mm, 1.00 µm HP-5MS, 30 m x 0.25 mm, 0.25 µm DB-1701P, 30 m x 0.25 mm, 0.25 µm DB-XLB, 30 m x 0.25 mm, 0.25 µm DB-35ms, 30 m x 0.25 mm, 0.25 µm HP-INNOWax, 60 m x 0.32 mm, 0.25 µm 122-1564 121-1524 122-1364 121-1324 19091S-433 122-7732 122-1232 122-3832 19091N-116 DB-23, 60 m x 0.25 mm, 0.25 µm 122-2362 HP-1, 60 m x 0.53 mm, 5.00 µm 19095Z-626 HP-1, 60 m x 0.25 mm, 1.00 µm 19091Z-236 HP PLOT Al2O3 "KCl", 50 m x 0.53 mm, 15 µm GS-Alumina, 50 m x 0.53 mm DB-1, 30 m x 0.53 mm, 5.00 µm HP-5MS, 30 m x 0.32 mm, 0.25 µm DB-XLB, 30 m x 0.25 mm, 0.25 µm DB-HT SimDis, 5 m x 0.53 mm, 0.15 µm 19095P-K25 115-3552 125-1035 19091S-413 122-1232 145-1001 D 5713 D 5739 D 5769 D 5790 D 5812 Standard Test Method for Determination of Organochlorine Pesticides in Water by Capillary Column GC D 5917 Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by GC and External Calibration Standard Test Method for Fatty and Rosin Acids in Tall Oil Fraction Products by Capillary GC Standard Test Method for Determination of Oxygenates, Benzene, Toluene, C8-C12 Aromatics and Total Aromatics in Finished Gasoline by GC/FTIR Standard Test Method for Trace Impurities in Alpha-Methylstyrene by Capillary GC Standard Test Method for Determination of Hydrocarbon Impurities in Ethylene by GC D 5974 D 5986 D 6144 D 6159 D 6160 Standard Test Method for Determination of PCBs in Waste Materials by GC D 6352 Standard Test Method for Boiling Range Distribution of Petroleum Distillates in Boiling Range from 174 to 700 by GC (Continued) AGILENT J&W GC AND GC/MS COLUMNS 557 GC Column Application and Method Guides ASTM Methods Method Title Recommended Agilent Column Part No. D 6387 Standard Test Methods for Composition of Turpentine and Related Terpene Products by Capillary Gas Chromatography Standard Test Method for Estimation of Engine Oil Volatility by Capillary GC Standard Test Method for Determination of Total Monoglyceride, Total Diglyceride, Total Triglyceride, and Free and Total Glycerin in B-100 Biodiesel Methyl Esters by Gas Chromatography Standard Practice for Analysis of Halogenated Organic Solvents and Their Admixtures by Gas Chromatography Standard Test Method for Analysis of Acetic Anhydride Using GC Standard Test Method for Analysis of Acrylonitrile by GC Standard Test Method for Analysis of Ethylene Glycols and Propylene Glycols CP-WAX 52 CB, 30 m x 0.32 mm, 0.50 µm CP-WAX 52 CB, 30 m x 0.53 mm, 1.00 µm CP8763 CP8738 DB-HT SimDis, 5 m x 0.53 mm, 0.15 µm 145-1001 Select Biodiesel, 15 m x 0.32 mm, 0.10 µm CP9078 CP-Sil 5 CB, 50 m x 0.53 mm, 5.00 µm CP7685 HP-1, 50 m x 0.32 mm, 0.52 µm 19091Z-115 DB-WAXetr, 60 m x 0.32 mm, 1.00 µm 123-7364 DB-624, 30 m x 0.53 mm, 3.00 µm CP-Wax 57 CB for Gycols and Alcohols, 50 m x 0.25 mm, 0.25 µm HP-5, 30 m x 0.53 mm, 5.00 µm 125-1334 CP7615 D 6417 D 6584 D 6806 E 1616 E 1863 E 0202 E 0475 Standard Test Method for Assay of Di-tert-Butyl Peroxide Using GC Tips & Tools GC Method Translation Software allows you to port a current GC method to another while ensuring that relative retention order is maintained so peaks elute in the same order. Download at www.agilent.com/chem/gcmethodtranslation 558 GC AND GC/MS www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com 19095J-623 GC Column Troubleshooting and Maintenance GC Column Troubleshooting and Maintenance These at-a-glance troubleshooting tables will help you pinpoint and fix the most common GC column problems. Please consult Agilent's J&W GC Column Installation Guide (publication number 830-0120) and the Agilent J&W GC Column Selection Guide (publication number 5989-6159EN) for more in-depth information, including: • Comprehensive column selection principles • Maintenance procedures, including column installation, conditioning, testing, and storage • Strategies for increasing your productivity • The most current method development procedures To request your copy of the Agilent J&W GC Column Selection Guide, visit www.agilent.com/chem/guides The Agilent J&W GC Column Installation Guide comes standard with every Agilent J&W GC column. You can also request a copy by contacting your local Agilent Representative or Agilent Authorized Distributor. AGILENT J&W GC AND GC/MS COLUMNS 559 GC Column Troubleshooting and Maintenance Excessive Baseline Noise Possible Cause Injector contamination Solution Clean the injector; replace liner, gold seal Column contamination Bake-out the column Solvent rinse the column Detector contamination Clean the detector Contaminated or low quality gases Use better grade gases; also check for expired gas traps or leaks Reinstall the column Column inserted too far into the detector Incorrect detector gas flow rates Leak when using an MS, ECD, or TCD Old detector filament, lamp or electron multiplier Septum degradation 560 GC AND GC/MS Adjust the flow rates to the recommended values Find and eliminate the leak Replace appropriate part Replace septum www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Comments Try a condensation test; gas lines may also need cleaning Limit the bake-out to 1-2 hours Only for bonded and cross-linked phases Check for inlet contamination Usually the noise increases over time and not suddenly Usually occurs after changing a gas cylinder Consult GC manual for proper insertion distance Consult GC manual for proper flow rates Usually at the column fittings or injector For high temperature applications use an appropriate septum GC Column Troubleshooting and Maintenance Baseline Instability or Disturbances Possible Cause Injector contamination Solution Clean the injector Unequilibrated detector Allow the detector to stabilize Incompletely conditioned column Change in carrier gas flow rate during the temperature program Column contamination Fully condition the column Normal in many cases Trim the column Solvent rinse the column Column activity Solvent-phase polarity mismatch Irreversible. Replace the column Change sample solvent to a single solvent Use a retention gap Decrease the initial column temperature Solvent effect violation for splitless or on-column injections Too low of a split ratio Increase the split ratio Poor column installation Some active compounds always tail Reinstall the column None Comments Try a condensation test; gas lines may also need cleaning Some detectors may require up to 24 hours to fully stabilize More critical for trace level analyses MS, TCD and ECD respond to changes in carrier gas flow rate Remove 0.5-1 m from the front of the column Only for bonded and cross-linked phases Check for inlet contamination Only affects active compounds More tailing for the early eluting peaks or those closest to the solvent front 3-5 m retention gap is sufficient Peak tailing decreases with retention Flow from split vent should be 20 mL/min or higher More tailing for early eluting peaks Most common for amines and carboxylic acids Split Peaks Possible Cause Injection technique Solution Change technique Mixed sample solvent Change sample solvent to a single solvent Poor column installation Sample degradation in the injector Reinstall the column Reduce the injector temperature Poor sample focusing Change to an on-column injection Use a retention gap Comments Usually related to erratic plunger depression or having sample in the syringe needle. Use an auto injector. Worse for solvents with large differences in polarity or boiling points Usually a large error in the insertion distance Peak broadening or tailing may occur if the temperature is too low Requires an on-column injector For splitless and on-column injection AGILENT J&W GC AND GC/MS COLUMNS 561 GC Column Troubleshooting and Maintenance Retention Time Shift Possible Cause Change in carrier gas velocity Solution Check the carrier gas velocity Change in column temperature Change in column dimension Large change in compound concentration Check the column temperature Verify column identity Try a different sample concentration Leak in the injector Blockage in a gas line Leak check the injector Clean or replace the plugged line Septum leak Sample solvent incompatibility Replace septum Change sample solvent to a single solvent Use a retention gap Comments All peaks will shift in the same direction by approximately the same amount Not all peaks will shift by the same amount May also affect adjacent peaks. Sample overloading is corrected with an increase in split ratio or sample dilution. A change in peak size usually occurs More common for the split line; also check flow controllers and solenoids Check for needle barb For splitless injection Change in Peak Size Possible Cause Change in detector response Solution Check gas flows, temperatures and settings Check background level or noise Change in the split ratio Change in the purge activation time Change in injection volume Change in sample concentration Check split ratio Check the purge activation line Check the injection technique Check and verify sample concentration Leak in the syringe Use a different syringe Column contamination Trim the column Column activity Coelution Change in injector discrimination Sample flashback Decomposition from inlet contamination 562 GC AND GC/MS Solvent rinse the column Irreversible Change column temperature or stationary phase Maintain the same injector parameters Inject less, use a larger liner, reduce the inlet temperature Clean the injector; replace liner, gold seal www.agilent.com/chem/gccolumns l 01357 522 961 www.crawfordscientific.com Comments All peaks may not be equally affected May be caused by system contamination and not the detector All peaks may not be equally affected For splitless injection Injection volumes are not linear Changes may also be caused by degradation, evaporation, or variances in sample temperature or pH Sample leaks past the plunger or around the needle; leaks are not often readily visible Remove 0.5-1 m from the front of the column Only for bonded and cross-linked phases Only affects active compounds Decrease column temperature and check for the appearance of a peak shoulder or tail Most severe for split injections Less solvent and higher flow rates are most helpful Only use deactivated liners and glass wool in the inlet GC Column Troubleshooting and Maintenance Loss of Resolution Possible Cause Solution Comments Check the column temperature Verify column identity Change column temperature Differences in other peaks will be visible Differences in other peaks will be visible Decrease column temperature and check for the appearance of a peak shoulder or tail Change in carrier gas velocity Column contamination Check the carrier gas velocity Trim the column A change in the retention time also occurs Remove 0.5-1 m from the front of the column Change in the injector Solvent rinse the column Check the injector settings Only for bonded and cross-linked phases Typical areas: split ratio, liner, temperature, injection volume Peak widths increase at higher concentrations For splitless injection Decrease in separation Different column temperature Different column dimensions or phase Coelution with another peak Increase in peak width Change in sample concentration Improper solvent effect, lack of focusing Try a different sample concentration Lower oven temperature, better solvent, sample phase polarity match, use a retention gap Tips & Tools Watch Agilent's in-depth video series cover common chromatographic problems, causes, and corresponding solutions presented by two of Agilent's seasoned GC experts at www.agilent.com/chem/gctroubleshooting AGILENT J&W GC AND GC/MS COLUMNS 563 LC AND LC/MS 710 LC AND LC/MS www.agilent.com/chem/LC www.crawfordscientific.com l 01357 522 961 In this Chapter Parts and Supplies 712 716 739 752 758 762 772 775 787 Bio-inert Supplies General Supplies Pump Supplies Autosampler Supplies Fraction Collector Supplies Valve Supplies TCC Supplies Detector Supplies LC/MS Supplies LC and LC/MS Columns 796 806 818 891 916 945 996 HPLC Column Selection Cartridge Column Systems Columns for Analytical HPLC Columns for Special Applications Preparative HPLC Columns and Flash Chromatography GPC/SEC Columns and Calibrants Biosolutions and Columns for Biologic Characterization LC and LC/MS Troubleshooting 1052 HPLC Troubleshooting 1056 LC/MS Troubleshooting LC and LC/MS Applications 1059 1076 1079 1088 1102 BioPharmaceutical Applications Chemical/Industrial Applications Environmental Applications Food and Consumer Product Applications Pharmaceutical Applications LC AND LC/MS 711 LC/MS Supplies LC/MS Supplies Combined with Agilent's industry-leading LC systems, our single quadrupole, ion trap, triple quadrupole, TOF and Q-TOF LC/MS solutions combine world-class performance with legendary reliability and ease-of-use. This section contains all of the mass spectrometry supplies you need to keep your LC mass spectrometer running at peak performance. LC/MS Maintenance Schedule Procedure Flush the nebulizer Clean the electrospray spray chamber Replace the electrospray nebulizer needle Clean the APCI spray chamber Replace the APCI nebulizer needle Clean the multimode source Check calibrant levels When to Perform Daily or at the end of each shift to flush traces of samples and buffers out of the tubing, valves, and nebulizer. Daily or anytime you suspect carryover contamination from one sample or analysis to another. When the needle is plugged. Common symptoms of a plugged needle are increased LC back pressure, off-axis spraying, or dripping from the nebulizer. Daily or anytime you suspect carryover contamination from one sample or analysis to another. When the needle is plugged. Common symptoms of a plugged needle are increased LC back pressure or off-axis spray from the nebulizer. Daily or anytime you suspect carryover contamination from one sample or analysis to another, or when you must access the end cap and capillary cap for cleaning and inspection. Monthly or weekly if you tune the LC/MS frequently. PARTS AND SUPPLIES 787 LC/MS Supplies LC/MS Preventive Maintenance Kit For your convenience, the LC/MS Preventive Maintenance Kit has the recommended common supplies needed for most Agilent LC/MS systems. Unique source parts should be ordered separately. LC/MS Preventive Maintenance kit Description LC/MS Preventive Maintenance kit Foreline pump oil, Inland 45, 1 L, for E1M18/E2M28 Oil mist filter element for E1M18/E2M28 Filter element, 5 µm, 5/pk Spring, canted coil, 4/pk Big hydrocarbon trap, 1/4 in. fittings Rotor seal, Vespel, pH 0 to 10 Tips & Tools Save ordering time and money with the LC/MS PM Kit! It contains the common supplies specified in Agilent service engineer preventive maintenance procedure for LC/MS platforms. 788 LC AND LC/MS www.agilent.com/chem/LC www.crawfordscientific.com l 01357 522 961 Part No. 5190-1443 6040-0834 1535-4970 0100-2051 1460-2571 BHT-4 0100-1855 LC/MS Supplies LC/MS Supplies Description ES nebulizer assembly, original ES nebulizer needle (original) replacement kit ES nebulizer assembly, new ES nebulizer needle (new) replacement kit APCI nebulizer assembly APCI nebulizer needle replacement kit Needle assembly APCI/Multimode Corona needle APCI/Multimode Capillary cap, high temperature, 3.0 mm Capillary, 0.5 mm ID, dielectric* Capillary, 0.6 mm ID, dielectric* Capillary, 0.6 mm ID, resistive, fast polarity switching* Spring, canted coil, 0.25 in. ID, 0.53 mm 1/6 in. tee, low dead volume, stainless steel 6100 Series Single Quadropole LC/MS ] ] ] ] ] ] ] ] ] ] ] 6200 Series TOF LC/MS ] ] ] ] ] ] ] ] ] ] ] ] ] 6300 Series Ion Trap LC/MS ] ] ] ] ] ] ] ] ] ] ] ] 6400 Series 6500 Series Triple AccurateQuadropole Mass Q-TOF LC/MS LC/MS Part No. ] ] G1946-60098 ] ] G2427A ] ] G1958-60098 ] ] G1958-60136 ] ] G1946-60037 ] ] G2428A ] G1947-60103 ] ] G1947-20029 ] ] G1946-20301 ] ] ] ] ] ] G1946-80009 59987-20040 G1960-80060 1460-2571 0100-0969 *Dielectric capillary supports standard polarity switching only. Resistive capillary supports fast polarity switching (Continued) Tips & Tools ES nebulizer (original) is compatible with the following ion sources: Corona needle APCI, G1947-20029 • ESI G1948A with Serial Number < US91801994 • ESI G1948B with Serial Number < US91201787 • Multimode G1978A with Serial Number < US90800804 • Multimode G1978B with Serial Number < US90700787 • Dual ESI G3251A with Serial Number < US91200355 • Dual ESI G3251B with Serial Number < US91200355 PARTS AND SUPPLIES 789 LC/MS Supplies LC/MS Supplies Description Syringe adapter Syringe pump 1/16 in. finger-tight PEEK fitting Female luer to female 10/32 adapter PEEK tubing Gas-tight syringe, PTFE luer lock High-throughput skimmer, 2 mm Skimmer 1 (G1956A/B) HED assembly HED assembly (G6140A, G6460A, G6530A) HED assembly Electron multiplier replacement horn Replacement horn and dynode 6100 Series Single Quadropole LC/MS 6200 Series TOF LC/MS ] ] ] ] ] 6300 Series Ion Trap LC/MS ] ] ] ] ] ] ] ] ] ] ] ] ] *Dielectric capillary supports standard polarity switching only. Resistive capillary supports fast polarity switching 05971-80103 790 LC AND LC/MS www.agilent.com/chem/LC www.crawfordscientific.com l 01357 522 961 6400 Series 6500 Series Triple AccurateQuadropole Mass Q-TOF LC/MS LC/MS Part No. 9301-1291 3162-0178 ] 0100-1516 ] 0100-2304 ] 0890-1915 ] 5182-9710 ] ] G1969-20302 G1956-20302 G1946-80019 ] G2571-80103 G1956-80000 ] 05971-80103 ] G2441-80010 LC/MS Supplies LC/MS Foreline Pump Supplies Description Oil mist filter kit for E1M18/E2M28 Oil mist cartridge filter for MS40+ Oil return kit Foreline pump oil, Inland 45, 1 L, for E1M18/E2M28 Rotary pump oil, 4 L, for E1M18/E2M28 Foreline exhaust adapter Hose clamp Oil mist filter element for E1M18/E2M28 KF25 clamp, stainless steel KF25 coseal (inside clamp) Exhaust tubing Pump oil drip pan Part No. 3162-1056 G1960-80039 3162-1057 6040-0834 6040-0798 59980-20134 1400-0563 1535-4970 0100-0549 0100-1597 0890-1727 G1946-00034 LC/MS Chemicals Description ES/APCI positive ion performance standard, 5 x 1 mL ampoules Electrospray LC demo sample (Sulfamix) ESI+APCI LC demo sample ES negative ion performance standard, 5 x 1 mL ampoules APCI negative ion performance standard, 5 x 1 mL ampoules ES/APCI positive ion performance standard Multiple-charge compound performance evaluation sample (horse heart myoglobin) Caffeine standards kit for LC/MS OQ/PV ES/APCI positive ion performance standard, 5 x 1 mL ampoules ES-TOF reference mix, 6 x 2 mL ampoules ES-TOF biopolymer reference standard kit Flushing solvent High purity water, 4 L Methyl alcohol, 1 L Ammonium formate Formic acid, 5 mL Acetonitrile, 1 L 6100 Series 6400 Series 6500 Series Single 6300 Series Triple AccurateQuadropole 6200 Series Ion Trap Quadropole Mass Q-TOF LC/MS TOF LC/MS LC/MS LC/MS LC/MS Part No. ] ] ] ] G2423A ] ] ]* 59987-20033 G1978-85000 ] ] G2424A ] G2425A ] G1946-85004 ] G2426A ] 8500-6917 ] G2423A ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] G1969-85001 G1969-85003 G1969-85026 8500-2236 8500-1867 G1946-85021 G2453-85060 G2453-85050 *Recommended item for familiarization PARTS AND SUPPLIES 791 LC/MS Supplies LC/MS Common Supplies* Description Part No. Common Parts Filter element, 5 µm, 5/pk Rotor seal, Tefzel, pH 0 to 14 Rotor seal, Vespel, pH 0 to 10 Inlet filter assembly SSV long drain tubing assembly Spring, canted coil 0100-2051 0100-1854 0100-1855 G1946-60180 G1969-60086 1460-2571 Cleaning Supplies Abrasive mesh, 4000 grit Capillary cleaning wire for dip tube Cleaning powder, dielectric capillary, Alconox Cloths, lint-free Cotton swabs, 100/pk 8660-0827 G1946-80054 5190-1401 05980-60051 5080-5400 Gas Purifiers Big hydrocarbon trap, 1/4 in. fittings Big moisture trap, 1/4 in. fittings Big universal trap, 1/4 in. fittings Big universal trap, 1/8 in. fittings, Nitrogen BHT-4 BMT-4 RMSN-4 RMSN-2 Tools LC/MS tool kit Nebulizer adjustment fixture Nebulizer 25X magnifier Plastic tubing cutter Screwdriver, Torx T15 Screwdriver, Torx T20 Open end wrench, 1/4 and 5/16 in. Wrench, 1/2 and 7/16 in. Needle nose pliers, pointed serrated jaws 3 mm wrench for nebulizer needle adjustment *These parts are common to all LC/MS systems Tips & Tools More information is a click away. We have a variety of educational primers, application notes, maintenance guides, and literature available from Agilent for free. To learn more, visit www.agilent.com/chem/OnlineLibrary 792 LC AND LC/MS www.agilent.com/chem/LC www.crawfordscientific.com l 01357 522 961 G1946-60157 G1946-20215 G1946-80049 8710-1930 8710-1622 8710-1615 8710-0510 8710-0806 8710-0004 8710-2699 LC/MS Supplies Quiet Cover Agilent has a solution to the frequent maintenance and inherent noise of LC/MS rough pumps. The Quiet Cover II was designed for easy movement, maintenance, and better living with rough pumps used with Agilent and other LC/MS systems. • Locking castors to move heavy pump for maintenance • No tools necessary to remove sectioned cover for easy access to pump • Built in lift-and-tilt lever raises end of pump to drain oil • Removable drip pan with well and hand holds to collect and transport oil • Sound absorbing cabinet with resistant foam insulation to reduce pump noise • Pump mounted on cushioned grommets to minimize vibration • 2 Integrated fans maintain temperature inside cover • LEDs and audible alarm if temperature exceeds 35°C limit • Maximum ambient temperature of 35°C when airflow is neither restricted nor recycled • Standard one-year warranty; installation and familiarization included with new LC/MS orders The Quiet Cover II is compatible with these Agilent LC/MS Systems that use Edwards pumps: • 6300 Traps: G2440DA, G2451AA, G4533AA, G2474SS • 6410 QQQ: G6410AA • 6210 TOF: G3250AA, G3252A • 6510AA Q-TOF: G6510AA • Any analytical system using BOC Edwards pumps (lbs/kg): E2M28, E2M18, E1M18 Quiet Cover Please confirm rough pump used in your Agilent LC/MS system to ensure compatibility. Quiet Cover II for Agilent LC/MS Systems Description Quiet Cover II for Agilent LC/MS Systems 12.5 W x 17.3 H x 33.5 L Part No. G3199B PARTS AND SUPPLIES 793 LC/MS Supplies LC/MS Standards Kits LC/MS Standards Kits Description Caffeine standards kit for LC/MS OQ/PV Includes 5 ampoules, 5 mL each: 0.5, 1.0, 5.0, 25.0, and 50.0 µg/mL in water Caffeine standards kit for LC/MS-Trap OQ/PV Includes 5 ampoules, 5 mL each: 0.1, 0.5, 1.0, 5.0, 10.0, µg/mL caffeine in water Sulfa drug standards kit for LC/MS OQ/PV 5 x 2 mL ampoules with 4 sulfa drugs in water/methanol 70:30 Part No. 8500-6917 5065-9908 5188-6523 LC/MS Analyzer Kit Standards Description LC/MS toxicology calibration mixture, 3 x 1 mL ampoules Method EN12916/IP391 LC standard calibration kit, 4 x 1 mL ampoules Method EN12916/IP391 system calibration standard kit, 2 x 1 mL ampoules LC TOF/QTOF/QQQ pesticide test mixture, 2 solutions, 3 x 1 mL ampoules of each Part No. 5190-0470 5190-0484 5190-0485 5190-0469 LC/MS Calibrant Mixes Description ESI tuning mix, 100 mL APCI/APPI calibrant solution, 100 mL ESI tuning mix for ion trap, 100 mL ES-TOF tuning mix, 100 mL APCI-L low concentration tuning mix, 100 mL MMI-L low concentration tuning mix, 100 mL Tips & Tools Agilent offers a variety of e-Seminars and on-site training to help you learn how to be a more effective chromatographer. For more information, visit www.agilent.com/chem/education 794 LC AND LC/MS www.agilent.com/chem/LC www.crawfordscientific.com l 01357 522 961 Part No. G2421A G2432A G2431A G1969-85000 G1969-85010 G1969-85020 LC/MS Supplies LC/MS Calibrant Mix and Source Compatibility Matrix Source ESI APCI APPI MMI NanoESI HPLC chip cube 6100 Series Single Quadropole LC/MS* G2421A G2432A G2432A G2432A 6140A/6150B Single Quadropole LC/MS G1969-85000 G1969-85010 G2432A G1969-85000 G1969-850002 6200 Series TOF LC/MS G1969-85000 G1969-85010 G1969-85010 G1969-85020 G1969-850004 G1969-850004 6300 Series Ion Trap LC/MS G2431A G2432A G2432A G2432A G2431A G2431A1 6400 Series Triple Quadropole LC/MS G1969-85000 G1969-850102 G2432A2 G1969-85020 G1969-850003 6500 Series Accurate-Mass Q-TOF LC/MS G1969-85000 G1969-850102 G1969-850102 G1969-85020 G1969-850004 G1969-850004 *G6110A, G6120A/B, G6130A/B 15X dilution suggested 2No autotune 3ESI positive tune only 4Calibration only PARTS AND SUPPLIES 795 HPLC Column Selection Flow Chart LC and LC/MS Columns HPLC Column Selection To use the column selection guide diagram below, simply follow the path for your analyte and mobile phase. At the far right, follow your final column selection to the pages indicated. Hexane Soluble Organic Solvent Soluble MeOH and MeOH: H2O or ACN and ACN: H2O Soluble THF Soluble Normal-Phase Mode with Bare Silica see pages 873-874 Normal-Phase Mode with Bonded Phase see pages 873-874 Reversed-Phase Mode with Bonded Phase Gel-Permeation (Small Molecule) see page 827 see pages 947-948 Molecular Weight <2000 Non-Ionic Water Soluble Reversed-Phase Mode with Bonded Phase see page 827 Reversed-Phase Mode with Bonded Phase Using Ionization Control see page 819 Reversed-Phase Mode with Bonded Phase Using Ion-Pair Agent see page 819 Reversed-Phase Mode with Bare Silica (HILIC) see page 877 Ion-Exchange Mode see page 879 Ionic Sample Organic Solvent Soluble Molecular Weight >2000 Water Soluble Gel-Permeation Chromatography Gel-Filtration Chromatography see page 997 Ion-Exchange Mode with Wide-Pore Material see page 1013 Reversed-Phase Mode with Wide-Pore Material see page 1016 Adapted with permission from "Practical HPLC Methodology and Applications," Brian A. Bidlingmeyer, John Wiley & Sons, Inc., New York, p. 109 796 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com see pages 947-948 l 01357 522 961 LC and LC/MS Columns Column and Mobile Phase Guidelines: Reversed Phase HPLC columns consist of two parts: the column chemistry and hardware. For the proper column chemistry, consult the catalog section for each type of bonded phase. For choosing column hardware and particle sizes, consult the section on column sizes and rapid separations, including Agilent ZORBAX Rapid Resolution HT, Solvent Saver, Capillary and PrepHT columns. Pore Size Selection Choose a column packing with small pore (60-120Å) if the solute molecular weight is less than about 5000. Otherwise, use column packing with the 300Å pore size. Particle Size Selection The typical particle size for HPLC columns is 5 µm with 3.5 µm and smaller now common in method development. If high-speed analyses or higher resolution analyses are required, packing with 1.8 µm and 2-3 µm particles can be used. Shorter columns with these particles can produce faster high-resolution separations, with the 1.8 µm particle size providing the highest efficiency and 2.7 µm superficially porous providing similar results. With 1.8, 2.7, 3.5 and 5 µm particle sizes to choose from, start with the smallest particle size for your HPLC or UHPLC – 400 bar, 600 bar, or 1200 bar – to achieve the best results. Column Configuration Choosing the best column size for method development has changed dramatically in the past few years. Smaller 3.0 mm ID or 2.1 mm ID columns are now used more than 4.6 mm ID to lower solvent use and achieve compatibility with MS detectors. And shorter 50, 75 and 100 mm long columns can be a great starting choice, with longer columns used only when more resolution is needed or when 3.5 and 5 µm particle sizes are used. LC AND LC/MS COLUMNS 797 LC and LC/MS Columns Silica Type and Bonded Phase Base Material The base material for an LC column is most often high purity silica material with totally porous particles such as that used in most Agilent ZORBAX columns. However, more choices are available, including polymer material with high pH stability used in PLRP-S columns and superficially porous silica particles such as those used in Poroshell 120 columns. The high purity Type B silicas, including the ZORBAX Rx-Sil used in ZORBAX Eclipse Plus, and superficially porous Poroshell 120, are an excellent first choice for most methods. Type A silicas, such as ZORBAX SIL, used in Original ZORBAX columns, are still manufactured and used in many methods. Bonded Phase A good first choice for bonded phase is C18 or C8, and the recommended starting column choices are Eclipse Plus C18 or Poroshell 120 EC-C18. These two choices provide excellent peak shape and can be used over the pH range 2-9, accommodating most typical LC and LC/MS mobile phases. If the sample solutes of interest are not adequately separated on these columns, CN and Phenyl columns – including Phenyl, Phenyl-Hexyl and Diphenyl – may offer significant differences in selectivity from straight-chain alkyl phases to effect the separation. pH and Mobile Phase The choice of mobile phase for a reversed-phase system starts with selecting the organic modifier. Acetonitrile is the most commonly used organic modifier. However, selectivity differences and sample retention will vary significantly among mobile phases containing acetonitrile, methanol, and tetrahydrofuran (THF). Sample solubility is likely to differ in such solvents and dictate use of a specific solvent or solvents. UV detection at certain wavelengths is not possible with certain modifiers (e.g., methanol at 200 nm). Tips & Tools Agilent offers a variety of e-Seminars and on-site training to help you learn how to be a more effective chromatographer. For more information, visit www.agilent.com/chem/education 798 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 LC and LC/MS Columns HPLC Column Stationary Phase Type of Surface Pore Size Column Dimensions Particle Size Inner Diameter Length Chemical Properties Physical Properties Chemical Lifetime/Selectivity Retention Factor Efficiency Sensitivity Speed Column Choice Relative to Application Objective Application Very high sensitivity, LC/MS, peptides and proteins Very high sensitivity, limited sample, LC/MS, peptides and proteins High sensitivity, limited sample, LC/MS Save solvent; special low-volume instrumentation is available Special detectors, e.g., mass spec High sensitivity, limited sample Save solvent; standard HPLC equipment available, LC/MS Standard separations Small-scale (mg) preparative separations Large-scale preparative separations (100 mg-gram) Large-scale preparative separations (up to 100 mg-gram) Objective Column Diameter (mm) 0.1, 0.075 0.3, 0.5 1.0 2.1 2.1 2.1 3.0 4.6 9.4 21.2 30, 50 Consult the Column Hardware section for guard column configurations LC AND LC/MS COLUMNS 799 Method Development Recommended Column Choices for Method Development Small Molecules Large Molecules MW < 2000 MW > 2000 Packing Pore Size 80-120Å 300Å The first choice of a packing pore size is based on the size of molecules to be analyzed. Typical small molecules can diffuse easily in and out of standard 80-120Å pore packings, but peptides and proteins may not. For this reason, use 300Å pore packings (300SB) for isocratic or gradient separations of peptides and proteins. Starting Column Bonded Phase Eclipse Plus C18 StableBond 300SB-C18 C18 is recommended as the starting column bonded phase for most samples since it maximizes retention for moderately polar to non-polar compounds. Shorter chain phases should be considered if resolution cannot be optimized with a C18 phase or if you are analyzing larger proteins. Starting Column Choices Small Molecules Large Molecules Standard Analysis Fast Analysis Standard Analysis Fast Analysis Eclipse Plus C18 Poroshell 120 EC-C18 ZORBAX 300SB-C18 ZORBAX 300SB-C18 4.6 x 150 mm, 3.5 µm 4.6 x 100 mm, 2.7 µm 4.6 x 150 mm, 5 µm 4.6 x 50 mm, 3.5 µm 959963-902 695975-902 883995-902 865973-902 Poroshell 120 EC-C18 Rapid Resolution HD Eclipse Plus C18, 1200 bar 4.6 x 75 mm, 2.7 µm Poroshell 300SB-C18 2.1 x 75 mm, 5 µm 2.1 x 50 mm, 1.8 µm 697975-902 660750-902 959757-902 800 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 USP Designations USP Designations The US Pharmacopeia (USP) is a standard source for many pharmaceutical methods that specifies columns by packing materials rather than by manufacturer. Listed below are the recommended Agilent Technologies HPLC columns suitable for most LC methods listed with the USP. USP Method USP Packing Materials Column Particle Size (µm) Page No. L1 Octadecyl silane chemically bonded to porous silica or ceramic micro-particles, 1.5 to 10 µm in diameter 2.7 2.7 1.8, 3.5, 5 1.8, 3.5, 5, 7 1.8, 3.5, 5, 7 3.5, 5 1.8, 3.5, 5, 7 3.5, 5, 7 5 3, 5, 10 3, 5, 10 3, 5, 10 3, 5 10 10 822 822 827 831 838 854 850 870 870 862 860 867 867 928 928 L2 Octadecyl silane chemically bonded to porous silica gel of a controlled surface porosity that has been bonded to a solid spherical core, 30 to 50 µm in diameter Porous silica particles, 5 to 10 µm in diameter Poroshell 120 EC-C18 Poroshell 120 SB-C18 ZORBAX Eclipse Plus C18 ZORBAX Eclipse XDB-C18 ZORBAX SB-C18 ZORBAX Rx-C18 ZORBAX Extend-C18 ZORBAX ODS ZORBAX ODS classic Pursuit XRs C18 Pursuit C18 Polaris C18-A Polaris C18-Ether SepTech ST60 C18 SepTech ST150 C18 N/A ZORBAX SIL ZORBAX Rx-Sil Pursuit XRs Si Polaris Si-A MicroSpher Si Microsorb 100 Si 5 3.5, 5 3, 5, 10 5, 10 5 5 873 873 862 867 L3 L4 L5 L6 Silica gel of controlled surface porosity bonded to a solid spherical core, 30 to 50 µm in diameter Alumina of controlled surface porosity bonded to a solid spherical core, 30 to 50 µm in diameter Strong cation-exchange packing: sulfonated fluorocarbon polymer coated on a solid spherical core, 30 to 50 µm in diameter N/A N/A (Continued) LC AND LC/MS COLUMNS 801 USP Designations USP Method USP Packing Materials Column Particle Size (µm) Page No. L7 Octyl silane chemically bonded to totally porous microsilica particles, 1.5 to 10 µm in diameter An essentially monomolecular layer of aminopropylsilane chemically bonded to totally porous silica gel support, 10 µm in diameter L9 10 µm irregular, totally porous silica gel having a chemically bonded, strongly acidic cation exchange coating Nitrile groups chemically bonded to porous silica particles, 3 to 10 µm in diameter 2.7 1.8, 3.5, 5 1.8, 3.5, 5, 7 1.8, 3.5, 5, 7 1.8, 3.5, 5, 7 5 3, 5, 10 3, 5, 10 3, 5 3, 5 5 5 5 5 5 spherical 822 827 831 838 854 870 856 856 865 865 L8 Poroshell 120 EC-C8 ZORBAX Eclipse Plus C8 ZORBAX Eclipse XDB-C8 ZORBAX SB-C8 ZORBAX Rx-C8 ZORBAX C8 Pursuit XRs C8 Pursuit C8 Polaris C8-A Polaris C8-Ether Microsorb 100 C8 ZORBAX NH2 Polaris NH2 Microsorb 100 Amino ZORBAX SCX ZORBAX CN ZORBAX SB-CN ZORBAX Eclipse XDB-CN Microsorb 100 Cyano ZORBAX TMS 5 3.5, 5 3.5, 5 5 5 873 838 831 ZORBAX SAX IonoSpher A 5 879 8 881 Hi-Plex Ca Hi-Plex Ca (Duo) 8 8 881 881 LiChrospher Diol 5 L10 L13 L14 L15 L16 L17 L18 L19 L20 Trimethylsilane chemically bonded to porous silica particles, 3 to 10 µm in diameter Silica gel 10 µm in diameter with a chemically bonded, strongly basic quaternary ammonium anion exchange coating Hexyl silane chemically bonded to totally porous silica particles, 3 to 10 µm in diameter Dimethyl silane chemically bonded to totally porous silica particles, 3 to 10 µm in diameter Strong cation exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the hydrogen form, 7 to 11 µm in diameter Amino and cyano groups chemically bonded to porous silica particles, 5 to 10 µm in diameter Strong cation exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the calcium form, 9 µm in diameter Dihydroxypropane groups chemically bonded to porous silica particles, 3 to 10 µm in diameter 873 865 879 MetaSil C6 N/A Hi-Plex H N/A (Continued) 802 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 USP Designations USP Method USP Packing Materials Column Particle Size (µm) Page No. L21 A rigid, spherical styrene-divinylbenzene copolymer, 5 to 10 µm in diameter L22 A cation exchange resin made of porous polystyrene gel with sulfonic acid groups, about 10 µm in size An ion exchange resin made of porous polymethacrylate or polyacrylate gel with quaternary ammonium groups, about 10 µm in size A semi-rigid hydrophilic gel consisting of vinyl polymers with numerous hydroxyl groups on the matrix surface, 32 to 63 µm in diameter Packing having the capacity to separate compounds with a MW range from 1,000 to 5,000 da (as determined by the polyethylene oxide), applied to neutral, ionic and cationic water-soluble polymers Butyl silane chemically bonded to totally porous silica particles, 5 to 10 µm in diameter Porous silica particles, 30 to 50 µm in diameter A multifunctional support, which consists of a high purity, 100Å, spherical silica substrate that has been bonded with anionic (amine) functionality in addition to conventional reversed-phase C8 functionality Gamma alumina, reversed phase, low carbon percentage by weight, alumina-based polybutadiene spherical particles, 5 µm diameter with a pore diameter of 80Å Ethyl silane chemically bonded to a totally porous silica particle, 3 to 10 µm in diameter A strong anion-exchange resin-quaternary amine bonded on latex particles attached to a core of 8.5 µm macroporous particles having a pore size of 2000Å and consisting of ethylvinylbenzene cross-linked with 55% divinylbenzene A chiral ligand-exchange packing L-proline copper complex covalently bonded to irregularly shaped silica particles, 5 to 10 µm in diameter Packing having the capacity to separate proteins by molecular size over a range of 4,000 to 400,000 da. It is spherical, silica-based, and processed to provide pH stability PLgel PLRP-S 100Å PLRP-S 300Å PLRP-S 1000Å Hi-Plex H 3, 5, 10, 20 3, 5, 8 3, 5, 8 5, 8 8 947 1027 1027 1027 881 PL aquagel-OH 5, 8 974 MicroSorb C4 5 L23 L24 L25 L26 L27 L28 L29 L30 L31 L32 L33 N/A N/A Bondesil Silica N/A 204 N/A N/A N/A N/A ZORBAX GF-250 Bio SEC-3 Bio SEC-5 4 3 5 1001 997 999 (Continued) LC AND LC/MS COLUMNS 803 USP Designations USP Method USP Packing Materials Column Particle Size (µm) Page No. L34 Strong cation exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the lead form, 9 µm in diameter A zirconium-stabilized spherical silica packing with a hydrophilic (diol-type) molecular monolayer bonded phase L-Phenylgylcine-3,5-dinitrobenzoyl on 5 µm amino propyl silica Polymethacrylate gel packing having the capacity to separate proteins by molecular size over a range of 2,000 to 4,000 da MW Methacrylate-based size exclusion packing for water solubles Hydrophilic polyhydroxymethacrylate gel of totally porous spherical resin Cellulose tris-3,5-dimethylphenylcarbamate coated porous silica particles, 5 to 20 µm in diameter Immobilized alpha-acid glyco-protein on spherical silica particles, 5 µm in diameter Octylsilane and octadecylsilane groups chemically bonded to porous silica particles Pentafluorophenyl groups chemically bonded to silica particles 5 to 10 µm in diameter A multifunctional support, which consists of a high purity, 60Å spherical silica substrate, that has been bonded with a cationic exchanger, sulfonic acid functionality in addition to a conventional reversed phase C8 functionality Beta cyclodextrin bonded to porous silica particles, 5 to 10 µm in diameter Polystyrene/divinylbenzene substrate agglomerated with quaternary amine functionalized latex beads, 10 µm in diameter High capacity anion exchange microporous substrate, fully functionalized with a trimethyl-amine group, 8 µm in diameter Sulfonated, cross-linked polystyrene with an outer layer of submicron, porous, anion-exchange microbeads, 15 µm in diameter Amylose tris-3,5-dimethylphenyl-carabamate-coated, porous, spherical, silica particles, 5 to 10 µm in diameter Hi-Plex Pb 8 881 ZORBAX GF-250 ZORBAX GF-450 4 6 1001 1001 3, 5 856 5 915 L35 L36 L37 L38 L39 L40 L41 L42 L43 L44 L45 L46 L47 L48 L49 N/A N/A N/A N/A N/A N/A N/A Pursuit PFP N/A ChiraDex Chiral N/A N/A N/A N/A (Continued) 804 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 USP Designations USP Method USP Packing Materials Column Particle Size (µm) Page No. L50 A strong cation exchange resin made of porous silica with sulfopropyl groups, 5 to 10 µm in diameter A reversed-phase packing made by coating a thin layer of polybutadiene on to spherical porous zirconia particles, 3 to 10 µm in diameter Multifunction resin with reversed-phase retention and strong anion-exchange functionalities. The resin consists of ethylvinyl-benzene, 55% cross-linked with divinylbenzene copolymer, 3 to 15 µm in diameter, and a surface area of not less than 350m2/g, substrate is coated with quaternary ammonium functionalized latex particles consisting of styrene cross-linked with divinylbenzene. An anion-exchange resin consisting of rigid, spherical styrene-divinylbenzene copolymer with trimethylammonium groups at a loading of about 2 meq per g, 3 to 29 µm in diameter Strong cation-exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the sodium form, about 7 to 11 µm diameter Weak cation-exchange resin consisting of ethylvinylbenzene, 55% cross-linked with divinylbenzene copolymer, 3 to 15 µm diameter. Substrate is surface grafted with carboxylic acid and/or phosphoric acid functionalized monomers. Capacity not less than 500 µeq/column Propyl silane chemically bonded to totally porous silica particles, 3 to 10 µm in diameter A chiral-recognition protein, ovomucoid, chemically bonded to silica particles, about 5 µm in diameter, with a pore size of 120 angstroms Strong cation-exchange resin consisting of sulfonated cross-linked styrene-divinylbenzene copolymer in the sodium form, about 6 to 30 µm in diameter Packing having the capacity to separate proteins by molecular weight over the range of 5 to 7000 kDa. It is spherical (5-10 µm), silica-based, and processed to provide hydrophilic characteristics and pH stability Spherical, porous silica gel, 10 µm or less in diameter, the surface of which has been covalently modified with alkyl amide groups and endcapped ZORBAX 300SCX 5 879 3, 5, 10 1006 SB-C3 3, 5 838 Ultron ES-OVM 5 913 Hi-Plex Na Hi-Plex Na (Octo) 10 8 881 881 1.8, 3.5, 5 3, 5 846 865 L51 L52 L53 L54 L55 L56 L57 L58 L59 L60 N/A N/A Bio SAX N/A N/A N/A Bonus-RP Polaris Amide-C18 LC AND LC/MS COLUMNS 805 Cartridge Column Systems CARTRIDGE COLUMN SYSTEMS Cartridge Selection Guide Icon* Type of Cartridge Agilent HPLC Cartridge ZORBAX Guard Cartridge: Standalone system ZORBAX Rapid Resolution and Rapid Resolution HT Cartridge Columns: 3.5 µm and 1.8 µm packings, standalone system ZORBAX Semi-Preparative Guard HPLC Hardware Kit: Standalone system ZORBAX and Agilent Prep Preparative Cartridge Column and Guard HPLC System: Standalone and integral hardware options ChromSep Column Hardware: Complete systems and replacement cartridges Features Can reverse collets in the end fitting to add guard cartridges Cartridges have a unique filter and sieve at each end High efficiency, standalone, Seals up to 400 bar low dead volume cartridge Polymeric cartridge designed for leak-tight seals No gaskets required against metal surfaces More solvent-resistant than PEEK Reusable fittings Adapt for connections to 1/16 in. LC fittings For high throughput LC/MS, LC/MS/MS and combinatorial separations Packed with Eclipse XDB for pH use from 2-9 For all analyte types Packed with StableBond for low pH use Low bleed Sold individually or as three-packs Easy, low-dead-volume assembly Seals up to 2000 psi (135 bar, 13.5 MPa) Tubing (polyphenylene sulfone) designed No gaskets required for leak-tight seals against metal surfaces Reusable fittings Adapt for connections to 1/16 in. LC fittings Easy, low-dead-volume assembly Extends column lifetime Reusable fittings Permits rapid column changes Hardware options for integral Can use with 21.2 and 30 mm ID columns and external guards Easy, no-dead-volume assembly *Look for these icons on subsequent pages to help you select the proper guard cartridges and columns. 806 LC AND LC/MS Benefits Inexpensive Extends column lifetime Permits rapid column changes Can use 2, 3, 4 and 4.6 mm cartridges Helps prevent blockage www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Economical format No tools required Modular flexibility Cartridge Column Systems Cartridge/Guard Cartridge Systems Compatibility Guide* Icon Column Type Cartridge column cartridge holder 5021-1845 Guard Cartridge Holder Guard cartridge (internal system) cartridge holder 5021-1845 ID (mm) 2.0 3.0 4.0 4.6 Phases Asahipak LiChrospher Nucleosil Purospher Superspher ZORBAX Standard fitting Column guard cartridge (standalone) cartridge holder 820999-901 2.1 3.0 4.6 ZORBAX Rapid Resolution cartridge holder 820555-901 No guard cartridge holder 4.6 ZORBAX Semi-preparative column Semi-prep guard cartridge (standalone) cartridge holder 840140-901 9.4 ZORBAX PrepHT Guard cartridge 820444-901 21.2 ZORBAX Agilent Prep *Standalone guard cartridges fit all cartridge and standard fitting columns available from Agilent. All columns without icons are standard fitting columns. LC AND LC/MS COLUMNS 807 Cartridge Column Systems Cartridge Column Systems Look for this icon identifying Agilent cartridge columns in column ordering tables Agilent offers a variety of popular HPLC packing materials in economical, easy-to-use cartridge configurations. Agilent Cartridge System Agilent’s flexible cartridge system has been thoroughly tested to ensure that the design and hardware meet Agilent’s quality standards. Finger-tight connections allow rapid column changes without removing capillaries from end fittings. The same convenient, easy-to-use cartridge holder accommodates 2, 3, 4 and 4.6 mm diameter cartridges of varying lengths. The cartridge columns have a unique filter and sieve at each end that help prevent blockage. By reversing the collets in the end fitting, an inexpensive guard cartridge can be added to further extend column lifetime. Guard cartridge installed Hardware Description Cartridge holder for 2, 3, 4 and 4.6 mm ID cartridges Replacement filters for 4 and 4.6 mm ID cartridges Replacement filters for 2 and 3 mm ID cartridges Mounting tool for replacement filters Replacement collets No guard cartridge installed Tips & Tools More information is a click away. We have a variety of educational primers, application notes, maintenance guides, and literature available from Agilent for free. To learn more, visit www.agilent.com/chem/OnlineLibrary 808 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Unit 2/pk 10/pk 10/pk 2/pk Part No. 5021-1845 5063-6574 5063-6519 5021-1846 5021-1849 Cartridge Column Systems ZORBAX High Performance Guard Cartridge This icon identifies standalone guard cartridges for ZORBAX analytical columns The ZORBAX High Performance Guard Cartridge series has been developed to provide convenient, cost-effective protection for high performance analytical columns. The cartridge components assemble quickly and easily to provide a high efficiency, low dead volume column that seals, with hand tightening, up to 5000 psi (340 bar) or 3000 psi with a PEEK fitting. The reusable guard column end fitting with integrated 1/16 in. OD tubing adapts the cartridge guard column for direct connection to standard 1/16 in. LC fittings and provides a standalone guard column system for 2.1 to 4.6 mm ID columns. There are two different end fitting options to allow the use of other connecting tubing. The polymeric guard cartridges used in this holder are specifically designed to make leak-tight seals against metal surfaces without requiring gaskets. This polymeric material (polyphenylenesulfone) is also more solvent resistant than PEEK. Guard cartridges are available for almost every ZORBAX bonded phase and can be found in the ordering information for each type of column. Hardware Description Guard fittings kit Includes low-volume guard holder, inlet end fitting (2), outlet end fitting with integrated column connector, and PEEK fingertight fitting Inlet end fitting, also used as alternate outlet end fitting Exit end fitting with integrated column connector 1/16 in. finger-tight PEEK fitting, 2/pk Perfluoro-Elastomer Seals, 2/pk Part No. 820999-901 820340-001 820345-001 0100-1516 820370-901 LC AND LC/MS COLUMNS 809 Cartridge Column Systems Rapid Resolution and Rapid Resolution HT Cartridge Column System (400 bar) Rapid Resolution and Rapid Resolution HT Cartridge Columns are marked with this icon For fast, clean high throughput LC/MS, LC/MS/MS and combinatorial separations, we recommend ZORBAX Rapid Resolution (3.5 µm) and Rapid Resolution HT (1.8 µm) Cartridge Columns. These cartridges are packed with ZORBAX Eclipse and StableBond bonded phases that provide excellent separations. Cartridge dimensions are 4.6 x 15 mm, 4.6 x 30 mm or 4.6 x 50 mm and 2.1 x 15 mm, 2.1 x 30 mm or 2.1 x 50 mm. All 15 and 30 mm cartridges are available in both Eclipse and StableBond phases in both the 3.5 µm and the very high efficiency 1.8 µm particles. The 1.8 µm particles are available as 50 mm cartridges and as 50 mm columns with fixed endfittings. Choose the Eclipse XDB bonded phases for most methods and when using LC/MS mobile phase additives such as formic acid or acetic acid. The StableBond phases are ideal for different selectivity and for long lifetime with TFA-containing mobile phases. Additional bonded phases can be packed upon request. These economical and easy-to-use cartridge columns are offered individually and in convenient three-packs. One cartridge holder kit includes all components for use with Rapid Resolution or Rapid Resolution HT columns. Hardware Description Hardware Kit for RR and RRHT Cartridges Includes cartridge holder 15 mm, cartridge holder 30 mm, cartridge holder 50 mm (1 ea), and end fitting assemblies (2) Cartridge holder, 15 mm Cartridge holder, 30 mm Cartridge holder, 50 mm Perfluoro-Elastomer Seals, 2/pk End fitting assembly, two required for one system 810 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Part No. 820555-901 820315-015 820330-030 820320-050 820370-901 820311-001 Cartridge Column Systems ZORBAX Semi-Preparative Guard Column Hardware Kit This icon identifies preparative guard columns The ZORBAX Semi-Preparative Guard Column has been developed to provide convenient, cost-effective protection for high-performance lab-scale semi-preparative columns. The cartridge components assemble quickly and easily to provide a high-efficiency, low-dead-volume column that seals at pressures up to 2000 psi (135 bar, 13.5 MPa). The guard column housing made from polyphenylene sulfone is specifically engineered to make leak-tight seals against metal surfaces, without requiring gaskets. The reusable guard-column end fittings adapt the cartridge guard column for connection to standard 1/16 in. LC fittings and provide a standalone guard column system. The ZORBAX materials used in preparative cartridges are matched with chemistry chosen for compatibility with a wide range of applications. Hardware Description Preparative guard column hardware kit* Includes inlet fitting, outlet end fitting, column connector Preparative guard system Part No. 840140-901 *The semi-preparative guard column hardware is available only as a kit. LC AND LC/MS COLUMNS 811 Cartridge Column Systems ZORBAX PrepHT and Agilent Prep Preparative Cartridge and Guard Column Hardware This icon identifies prep preparative cartridge and guard columns Guard Cartridge, 820444-901 The ZORBAX PrepHT and Agilent Prep Preparative Cartridge and Guard Column hardware kits have been developed to provide a convenient preparative 21.2 mm ID cartridge design. The 21.2 mm ID preparative cartridge columns (actual ID 17 mm to fit into holder) are reusable and allow rapid change of column lengths from 50 to 250 mm for optimizing sample loadability. This easy-to-use cartridge hardware design is used for both ZORBAX PrepHT and Agilent Prep materials and can be finger-tightened up to 5000 psi (350 bar). The cartridge hardware can be used standalone or with an integral guard column. The integral guard column holder is a stainless steel body and is used with a PTFE sealing gasket to ensure a tight, leak-free and extremely low-dead-volume seal against the 21.2 mm ID cartridge body. The external guard system seals finger-tight up to 2000 psi (135 bar). The reusable guard holder is ready-to-use with standard 1/16 in. LC fittings. Both ZORBAX and Agilent Prep guard cartridges are available to use with this holder and are selected to match the preparative column used in the application. The 21.2 mm ID guard columns can be used with 30 mm ID Agilent Prep columns. For this application, select the external preparative guard column hardware kit. Prep external guard hardware kit, assembled, 420420-901 PrepHT Columns are easy to use Column Cartridge Seal Holder and Seal Pusher Guard Column End Fitting Standard End Fitting Guard Column Polymeric Seal Polymeric Seals PrepHT cartridge columns have a unique design that makes them easy to install and seal finger-tight up to 5000 psi. The cartridge design allows for an integral guard column to be used, which prolongs the life of the purification column. This cartridge configuration is economical to use since the column cartridge and/or the guard cartridges are replaced independently. The end fittings are used many times. 812 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Cartridge Column Systems Hardware Description PrepHT cartridge column hardware Includes cartridge column end fittings (2), polymeric seals (2) PrepHT guard column hardware kit Includes guard column end fitting, polymeric seal, and seal insertion tool (seal holder and seal pusher) Agilent Prep external guard hardware kit, Includes guard holder, guard column end fitting, polymeric seal (2), seal insertion tool, and connector tubing Replacement polymeric seals, 2/pk Part No. 820400-901 820444-901 420420-901 820385-901 ChromSep HPLC Column Hardware This icon identifies ChromSep column hardware The ChromSep system combines simplicity with extraordinary flexibility and considerable savings on column and operating costs. The ChromSep 316 stainless steel column-housing hardware is a durable one-time investment. Once you have purchased the complete basic system of a holder, analytical cartridge and guard column, you will only need to replace the cartridges or replacement guard columns, both of which are available in economical packages: 3-pack analytical column replacements and 5-pack guard column replacements for added value. Unlike other modular column systems, ChromSep is extremely flexible. Column housings are available in lengths of 10, 30, 50, 100, 150 and 250 mm, and cartridges are available in various IDs ranging from 2 to 4.6 mm. You can use any combination of cartridge columns to match the column length with the separation you need and minimize your analysis time. Tips & Tools Guard columns and filters help protect your column and instrument from particulates that can cause blockages, which increase system pressure and negatively impact performance. Learn more about this common problem at www.agilent.com/chem/lctroubleshooting LC AND LC/MS COLUMNS 813 HPLC Column Protection HPLC Column Protection Column Protection Guard columns and in-line filters are inexpensive and easy-to-use tools for column protection. They can improve the accuracy of your results and improve analytical column lifetime while enhancing reliability. Column protection is available for all sizes of columns with any particle size packed into the column. Guard Columns Guard columns provide protection against contamination with minimal impact on column efficiency. Prepacked ZORBAX cartridge columns are available for most types of ZORBAX material. Guard cartridges are available in different internal diameters to provide high efficiency protection to all types of columns. Guard columns are also available for many non-Zorbax columns. See the respective column listings for available guard columns. Low Volume In-line Filters Low volume in-line filters are recommended for every column and provide column protection from particulate materials. An in-line filter will increase analytical column lifetime by preventing particulates (from unfiltered samples and/or eluents) from plugging the analytical column frit. Using guard columns can compromise the efficiency of very low volume columns and/or columns with very small particle sizes. For these columns, low volume in-line filters are strongly recommended. A small, 0.5 µm frit should be used to maximize column efficiency. Replacement Column Inlet Frits If HPLC columns are used without a guard column on in-line precolumn filters, the analytical column may become plugged. Due to the high efficiency packing processes used today, replacing the column inlet frit is discouraged. Column efficiency may be compromised if the frit is replaced. PEEK-encapsulated replacement frits are available for ZORBAX columns packing in 2.1, 3.0, 4.6, and 9.4 mm standard column hardware. Replacement Inlet Frits (PEEK Encapsulated) for Standard Hardware Columns Description Narrow Bore Solvent Saver Analytical Semi-Preparative 814 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com Diameter (mm) 2.1 3.0 4.6 9.4 l 01357 522 961 Unit 10/pk 1/ea 10/pk 1/ea Part No. 280959-904 280959-006 280959-905 280959-001 Agilent ZORBAX Silica Agilent ZORBAX Silica ZORBAX Silica Manufacturing Process – the Making of a Rugged, High-Purity Silica All Agilent ZORBAX columns are built from porous silica microspheres (PSM) based on silica sols. The silica particle is made of tiny, solid sol microparticles agglutinated in a patented polymerization process, then fused together at very high temperatures to form the final particle (Figure 1). These strong, durable silica particles are called ZORBAX Rx-SIL or ZORBAX SIL and are the base silicas for ZORBAX columns. The ZORBAX Rx-SIL process produces ultra-pure (99.995%) particles, with very low metal content. The final silica particle is fully hydroxylated and of low acidity. The Rx-SIL process also allows careful and reproducible control of pore size and particle size. These key features – purity (low acidity), strength, and careful control of pore and particle size – are critical to excellent chromatographic results and are the building blocks of superior ZORBAX bonded phases. The table compares the processes used to make the ZORBAX Rx-SIL particles to a second process – the Xerogel process – commonly used to make silica particles for HPLC columns. To produce silica with the key features that maximizes chromatographic performance – purity, strength, controlled pore and particle size, plus higher pH resistance – the Agilent ZORBAX process is an excellent choice. 80Å or 300Å pore SilicaSol + Urea (pH~2) + CH 2O O2 1.8 3.5 µm 5, 7 Eclipse Plus Eclipse XDB StableBond SB, 300SB Bonus-RP Extend-C18, 300Extend-C18 Figure 1. Formation of ZORBAX porous silica particles LC AND LC/MS COLUMNS 815 Agilent ZORBAX Silica Characteristics of ZORBAX Rx-SIL and a Contrasting Type of Silica ZORBAX Rx-SIL uniform sub particles Structure Purity Strength Pore Size, Particle Size Distribution Pore Size/Surface Area Porosity (%) High pH Resistance ZORBAX Rx-SIL (Sol-type) High (99.995%) High Narrow 80Å/180 m2/g 60 Good Xerogel (SIL-type) Low to High Moderate Broad 100Å/300 m2/g 70 Poor The Benefit of Silica Purity – Reduced Peak Tailing Xerogel "sponge-like" polymeric network Peak tailing of basic compounds can be a major chromatographic problem. Peak tailing reduces chromatographic efficiency and the accuracy and precision of results. The major cause of peak tailing is interactions between analytes and the silica surface (Figure 2). Typically the presence of acidic silanol sites on the silica surface cause this type of peak tailing. Trace metals in silica increase silanol acidity and peak asymmetry. These silanol interactions are reduced or eliminated by choosing a less acidic, ultra pure (99.995%) silica, such as ZORBAX Rx-SIL. The improvement in chromatography is dramatic. Figure 3 shows the reduction in peak tailing for a basic analyte using ZORBAX Rx-SIL versus a more acidic silica. Silica Particle Original ZORBAX SIL (1973) SiO - Na + + R3NH + Silica Particle SiO - NH +R 3 + Na + 1. Ionized silanols (SiO- ) will ion-exchange with protonated bases (R 3NH +) which can cause tailing and method variability CH 2-OH . NH 2 Silica Particle -SiOH + RCOO - CH 2CH 3 Silica + Particle -SiO - ...H ... - OOCR 2. Unprotonated acids can compete for H + with protonated silanols. Figure 2. Potential secondary interactions with silica silanols and ionizable compounds Highly Purified ZORBAX Rx-SIL NH 2 CH 2CH 3 CH 2-OH Mobile Phase: 5% Propanol in Heptane Flow Rate: 2.0 mL/min Figure 3. Chromatographic improvement using highly purified ZORBAX Rx-SIL 816 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Agilent ZORBAX Silica The Benefits of Strong Particles – Greater Efficiency and Durability During the silica manufacturing process, the agglutinated sol particles are sintered for increased strength. This improved mechanical stability allows ZORBAX columns to be packed at high pressures when needed – up to 14,000-15,000 psi. This results in a packed column with an exceptionally stable column bed that will not compress under normal or even high operating pressures – up to 18,000 psi (1200 bar). This packed bed stability increases column lifetime using ZORBAX 1.8, 3.5, 5 or 7 um particles. When ZORBAX Rapid Resolution HD or HT 1.8 µm and Rapid Resolution 3.5 µm silica particles are used as the underlying support, high speed, high efficiency chromatography is possible without compromising column lifetime. The Benefits of Careful Pore Size and Particle Size Control – High Efficiency and Better Reproducibility with More Column Choices Accurate and closely monitored particle and pore size control for ZORBAX Rx-SIL produces reproducible retention behavior from column-to-column and lot-to-lot. The narrow, consistent particle size distribution of ZORBAX Rx-SIL particles maximizes efficiency and column bed stability. Column pressure is never unusually high due to "fines" – smaller particles at the low end of the particle size distribution. Accurate and precise control of particle size allows specific 1.8, 3.5, 5 and 7 µm particles to be produced. The small 3.5 µm and 1.8 µm particle sizes are the basis for the Rapid Resolution and Rapid Resolution HD and HT, high-speed analysis columns designed to maximize resolution in shorter column lengths – ideal for LC/MS or any application demanding shorter analysis times. The 5 µm particles are an industry standard and provide high resolution in a wide variety of column dimensions. This particle size also provides high efficiency in a short preparative configuration – the PrepHT column – because careful particle size control means consistent pressure expectations within normal operating limits. The 7 µm particle size provides the ideal balance between efficiency and operating pressure for longer preparative columns. ZORBAX Rx-SIL – The Foundation for Many Bonded Phases With such strong performance characteristics, ZORBAX Rx-SIL particles have been developed into many effective bonded phases for solving key analytical problems. These include columns that can be used at extremes of pH, unmatched by any other silica-based columns. Because silica-based columns have different limitations at low and high pH, specific bonded-phase chemistries are required to provide longer column life over different pH ranges. As a result, Agilent ZORBAX RP-HPLC bonded phases are designed to give extended column lifetime and reproducibility in the pH ranges that provide optimum and long-lasting resolution, all starting with high performance ZORBAX Rx-SIL. LC AND LC/MS COLUMNS 817 Columns for Analytical HPLC AGILENT COLUMNS FOR ANALYTICAL HPLC Achieve excellent peak shape and resolution – and eliminate "false starts" Good news for analysts who do not have time to "make columns work" for a particular application: Agilent columns let you choose the right column based on your sample and mobile phase – eliminating any guesswork. Additionally, Agilent’s ZORBAX silica is manufactured by Agilent – not purchased from outside suppliers. And that means we control every step of the manufacturing process, ensuring lot-to-lot consistency, superior performance, and long-term, reliable results. In this section, you will find a diverse range of columns designed for optimum resolution over a wide pH range, including: • Poroshell 120 HPLC Columns • ZORBAX Reversed-Phase HPLC Columns • Pursuit HPLC Columns • Polaris HPLC Columns • ZORBAX Normal-Phase HPLC Columns • ZORBAX and Hi-Plex Ion Exchange HPLC Columns • ZORBAX Method Development and Validation Kits Tips & Tools All ZORBAX and Poroshell conventional columns (non-cartridge) come with a QC chromatogram. Run a standard sample of QC components or key analytes from your lab on each new column before use, and keep this chromatogram in your log book. Periodically re-run this test to see how your column has aged. Learn how this can help with troubleshooting issues by watching the videos at www.agilent.com/chem/lctroubleshooting 818 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC Agilent Reversed-Phase Columns The following table summarizes the unique bonding chemistry of ZORBAX RP-HPLC columns. Each is designed for long column lifetime and resolution that lasts. Agilent RP-HPLC Column Chemistry Bonus-RP Extend-C18 B B Totally porous Totally porous Triple Double Rx-C18 Pursuit Pursuit XRs Polaris A Polaris Ether Polaris Amide B B B B B B Totally porous Totally porous Totally porous Totally porous Totally porous Totally porous None Single Single Single Single Single Side Group Structure on Silane Dimethyl Diisobutyl Dimethyl Dimethyl Diisopropyl (C8, C3, CN, phenyl), diisobutyl (C18) Diisopropyl Unique bidentate structure Dimethyl Dimethyl Dimethyl Dimethyl Dimethyl Dimethyl Original ZORBAX Columns** ZORBAX ZORBAX ODS Classic A A Totally porous Totally porous Single None Dimethyl Dimethyl Modern Columns* Poroshell 120 EC Poroshell 120 SB Eclipse Plus Eclipse XDB StableBond Silica Type B B B B B Particle Type Superficially porous Superficially porous Totally porous Totally porous Totally porous Endcapping Double None Double Double None Polar Group None None None None None Page No. 822 822 827 831 838 Amide None 846 850 None None None Yes Ether Amide 854 856 862 865 865 925 None None 870 870 *Type B silica: low acidity, low metal content; these bonded phases use ZORBAX Rx-SIL **Type A silica: more acidic, higher metal content LC AND LC/MS COLUMNS 819 Columns for Analytical HPLC Quick Guide to Agilent Reversed-Phase Bonded Phases Modern RP-HPLC Columns Poroshell 120 Recommended Uses and Applications � Superficially porous particles for high efficiency at low pressure � Sub-2 µm efficiency with a 2.7 µm particle � Endcapped and non-endcapped C18 and C8 phases for selectivity optimization � Compatible with 400 bar and 600 bar LC's Page No. 822 Eclipse Plus � Excellent first choice for method development � Long life from pH 2-9 for reliable separations of basic, acidic and neutral compounds � Superior peak shape with basic compounds � High resolution and efficiency with 1.8, 3.5 and 5 µm columns � Rigorous QA/QC testing for greater long-term reproducibility 827 Eclipse XDB � Four selectivity choices for flexible method development � High performance over a wide pH range (2-9) � Good peak shape for acids, bases and neutrals � Long lifetime with extra dense bonding and double endcapping � Fast, ultra-fast, and high resolution separations using 1.8 and 3.5 µm columns � Choices from capillary to prep 831 StableBond (SB) � Basic, acidic, neutral compounds � Exceptional stability at low pH (1-2) � Use of high temperature (up to 90°C for C18, 80°C for C8, C3, Phenyl, CN, and Aq) and low pH as an added selectivity tool � Widest selection of bonded phases for different selectivity (C18, C8, C3, CN, Phenyl, Aq) � Uses mobile phases for LC/MS with formic acid, acetic acid, or TFA � Uses mobile phases with TFA for peptide and protein separation � Rapid separations using 1.8 and 3.5 µm columns 838 Bonus-RP � Separating basic compounds in higher aqueous mobile phases � General separation of basic, neutral, acidic compounds at mid-range pH or low pH; especially stable at low pH � Separating peptides for different selectivity � Rapid separations using 3.5 µm columns 846 (Continued) 820 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC Quick Guide to Agilent Reversed-Phase Bonded Phases Modern RP-HPLC Columns Extend-C18 Recommended Uses and Applications � Separating basic compounds above their pKa in free base form; separation of basic, acidic, neutral compounds at high pH; up to pH 11.5 � Uses ammonium hydroxide as mobile phase additive with LC/MS with small molecules or peptides � Separating at high, mid-range and low pH for selectivity changes � Rapid separations using 3.5 µm columns Page No. 850 ZORBAX Rx � General separation of basic, acidic and neutral compounds at low pH with different selectivity than SB columns � Rx-C8 is the same as SB-C8 854 Pursuit � Good separations of a wide range of analytes � Diphenyl and Pentafluorophenyl bonded phases for unique selectivity � 200Å pore size for separations of larger molecules 856 Pursuit XRs � High carbon load for excellent retention and resolution � Basic, acidic, and neutral compounds � Unique diphenyl bonded phase for separations based on pi-pi selectivity 862 Polaris A � Good for polar acids, polar bases and non-polar compounds � High aqueous compatibility 865 Polaris Ether � Additional selectivity for H-bond donors � High aqueous compatibility � No "phase collapse" 865 Recommended Uses and Applications Page No. 870 Original ZORBAX Columns ZORBAX � General separation of basic, acidic, neutral compounds at low pH with different selectivity than SB columns; higher number of active silanols than SB � "Mixed mode" separation at more neutral pH values ZORBAX ODS Classic � General separation of basic, acidic, neutral compounds at mid-range to low pH with different selectivity than SB or XDB columns (non-endcapped) 870 LC AND LC/MS COLUMNS 821 Columns for Analytical HPLC Poroshell 120 • Up to 90% of the efficiency of sub-2 µm • 2X the efficiency of 3.5 µm • Up to 50% less pressure than sub-2 µm columns • Ideal for use up to 600 bar for HPLC and UHPLC • Three bonded phases with excellent selectivity and peak shape Agilent Poroshell 120 columns are a 2.7 µm particle with a 1.7 µm solid core and 0.5 µm porous outer layer. This small particle size provides high efficiency, similar to sub-2 µm columns, but with 40-50% less pressure. These high efficiency, high resolution columns can be used on any type of LC. The porous outer layer and solid core limit diffusion distance and improve separation speed while the narrow particle size distribution improves efficiency and resolution. The solid core limits diffusion distance and improves separation speed. The columns can support high pressure and multiple columns can be used for the highest resolution and efficiency possible. The same principles are used in Poroshell 300 columns, ideal for fast, high resolution separations of biomolecules. Column Specifications Bonded Phase SB-C18 EC-C18 EC-C8 Pore Size 120Å 120Å 120Å Temp. Limits pH Range 90°C 1.0-8.0 60°C 2.0-8.0 60°C 2.0-8.0 Specifications represent typical values only. Tips & Tools Method transfer from a conventional 3.5 or 5 µm column is easy, and often requires only minor adjustments to your method and no revalidation. Learn more at www.agilent.com/chem/poroshell120video 822 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Endcapped No Double Double Carbon Load 8% 10% 5% Columns for Analytical HPLC Poroshell 120 Description Analytical Analytical Analytical Analytical Analytical Solvent Saver Solvent Saver Solvent Saver Solvent Saver Solvent Saver Narrow Bore Narrow Bore Narrow Bore Narrow Bore Narrow Bore Size (mm) 4.6 x 150 4.6 x 100 4.6 x 75 4.6 x 50 4.6 x 30 3.0 x 150 3.0 x 100 3.0 x 75 3.0 x 50 3.0 x 30 2.1 x 150 2.1 x 100 2.1 x 75 2.1 x 50 2.1 x 30 Particle Size (µm) 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 SB-C18 USP L1 683975-902 685975-902 687975-902 689975-902 681975-902 683975-302 685975-302 687975-302 689975-302 681975-302 683775-902 685775-902 687775-902 689775-902 681775-902 EC-C18 USP L1 693975-902 695975-902 697975-902 699975-902 691975-902 693975-302 695975-302 697975-302 699975-302 691975-302 693775-902 695775-902 697775-902 699775-902 691775-902 EC-C8 USP L7 693975-906 695975-906 697975-906 699975-906 691975-906 693975-306 695975-306 697975-306 699975-306 691975-306 693775-906 695775-906 697775-906 699775-906 691775-906 Tips & Tools Agilent offers a variety of e-Seminars and on-site training to help you learn how to be a more effective chromatographer. For more information, visit www.agilent.com/chem/education LC AND LC/MS COLUMNS 823 Columns for Analytical HPLC Superficially porous particles provide similar performance to sub-2 µm particles This Van Deemter curve shows that Poroshell 120 – a superficially porous, 2.7 µm particle column – can deliver reduced plate heights similar to a 1.8 µm column for similar efficiency. 10 9 Agilent Poroshell 120 EC-C18 3.0 x 100 mm, 2.7 µm (USCFX01009) P/N 695975-302 8 7 6 Agilent ZORBAX Eclipse Plus C18 3.0 x 100 mm, 1.8 µm (USUYB01455) P/N 959964-302 5 4 Agilent ZORBAX Eclipse Plus C18 3.0 x 100 mm, 3.5 µm (USUXV01435) P/N 959961-302 3 2 1 0 0 2 4 6 8 10 12 µ (mm/s) UHPLC efficiency at HPLC pressures 2.223 0.826 LC AND LC/MS 9.753 6.273 4.132 2.816 1.518 2.016 1.148 0.646 2.705 2.5 824 5 7.5 10 B Agilent Eclipse Plus C18, 3.0 x 100 mm, 1.8 µm PN 959964-302 www.agilent.com/chem/lccolumns www.crawfordscientific.com N = 25053, Press = 182 bar 5 l 01357 522 961 7.5 13.041 8.21 8 5.281 3.494 2.418 For this sample of neutral alkylphenones, the Poroshell 120 column delivered >90% of the efficiency attained by the 1.8 µm column. Also note that the pressure on the Poroshell 120 column is about 50% of the pressure on the 1.8 µm column. N = 25053, Press = 182 bar 2.5 1.756 Sample: 60% Acetonitrile:40% Water 0.58 mL/min 60°C 4 µL DAD Sig = 254,4 nm Ref = 360,100 nm (PN 5188-6529) spiked w/50 µL 2 mg/mL Thiourea in water/acetonitrile (65:35) 0.865 Mobile Phase: Flow Rate: Temperature: Injection Volume: Detector: A Agilent Poroshell 120 EC-C18, 3.0 x 100 mm, 2.7 µm PN 695975-302 1.275 Column B: Poroshell 120 EC-C18 695975-302 3 x 100 mm, 2.7 µm Eclipse Plus C18 959964-302 3.0 x 100 mm, 1.8 µm 0.649 Column A: 10 12.5 min Columns for Analytical HPLC The simpler the manufacturing process, the more consistent the column A single-step shell process creates a highly reproducible column, as you can see in this lot-to-lot comparison. Agilent Poroshell 120 EC-C18 4.6 x 100 mm, 2.7 µm P/N 695975-902 – from 4 Different Lots B10014 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3 0.5 1 1.5 2 2.5 3 min B10015 B10016 B10018 Poroshell 120 EC-C8 is less retentive for faster analysis of non-polar compounds Column A: Column B: Mobile Phase: Flow Rate: Temperature: Detector: Sample: Poroshell 120 EC-C18 699975-302 3 x 50 mm, 2.7 µm Poroshell 120 EC-C8 699975-306 3.0 x 50 mm, 2.7 µm 60% CH3CN:40% H2O 0.85 mL/min 26°C 254 nm 2 µL of RRLC Checkout Sample (PN 5188-6529), alkylphenones A mAU 300 250 200 150 100 50 0 0.5 1 1.5 2 2.5 3 3.5 min 0.5 1 1.5 2 2.5 3 3.5 min B mAU 300 250 200 150 100 50 0 LC AND LC/MS COLUMNS 825 Columns for Analytical HPLC USP method for Naproxen tablets – 4.5X faster analysis on Agilent Poroshell 120 at HPLC pressures Mobile Phase: Flow Rate: This Naproxen separation demonstrates how easy it can be to convert a method to Poroshell 120 columns without changing the flow rate or mobile phase. 50:49:1 MeCN:H2O Acetic Acid 1.2 mL/min 4.6 x 150 mm (L1) Agilent Eclipse Plus C18, 5 µm P/N 959993-902 20 µL injection Rs = 14.9 N=14,885 mAU 30 1. Naproxen 2. Butyrophenone 25 N=12,554 20 15 10 5 0 1 2 3 4 5 2X Faster mAU 30 N=20,676 20 7 8 9 min 4.6 x 100 mm (L1) Agilent Poroshell 120 EC-C18, 2.7 µm P/N 695975-902 13.67 µL injection Rs = 17.0 P = 238 bar N=21,046 25 6 15 10 5 0 1 2 3 4 5 4.5X Faster mAU 30 N=12,051 20 7 min 4.6 x 50 mm (L1) Agilent Poroshell 120 EC-C18, 2.7 µm P/N 699975-902 6.7 µL injection Rs = 12.6 P = 133 bar N=11,281 25 6 15 10 5 0 1 2 Agilent Poroshell 120 columns in series deliver the highest efficiency at HPLC and UHPLC pressures Because low backpressure is one of the advantages of Poroshell 120 columns, you can couple several columns in series to achieve the highest separation power per unit time. This enables better separation of complex samples. 3 4 5 6 7 min 3 Agilent Poroshell 120 EC-C18 columns in series 693975-902 4.6 x 150 mm, 2.7 µm mAU 17.5 15 Flow Rate: 1 mL/min N~83000 (peak 4) Max Pressure: 316 bar 12.5 10 7.5 5 2.5 Peak # 2 3 4 Compound Acetophenone Benzene Touene Plates 114120 109931 114800 k’ 0.29 0.46 0.65 0 0 1 2 3 4 5 6 min 2 3 4 5 6 min mAU 17.5 15 Flow Rate: 1.5 mL/min N~103000 (peak 4) Max Pressure: 478 bar 12.5 10 7.5 5 2.5 0 0 1 mAU 17.5 15 Maximum efficiency at 1.8 mL/min Flow Rate: 1.8 mL/min N~115000 (peak 4) Max Pressure: 573 bar 12.5 10 7.5 5 2.5 0 0 1 2 3 4 5 6 min LC2011_120 826 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC ZORBAX Eclipse Plus • Excellent peak shape for basic compounds • High level of performance – peak shape, efficiency, resolution, and lifetime – with all sample types: acids, bases and neutrals • Superior reproducibility with more rigorous QA/QC testing • Improved, patented silica manufacturing with start-to-finish product control • Available in 1.8, 3.5 and 5 µm particle sizes for all analytical, high resolution, and fast LC analyses Agilent ZORBAX Eclipse Plus columns provide the ultimate in performance for silica-based columns. Peak shape is excellent for the most challenging basic compounds, improving efficiency and resolution with these sample types. These results are achieved by improvements in the silica manufacturing and bonding technology, which is completely controlled by Agilent. Because of their high level of performance, Eclipse Plus columns are the ideal first choice for method development of all samples. If you need to achieve fast method development and superior productivity, then choose a column with high-resolution 1.8 µm particles. For standard methods, conventional 5 µm and Rapid Resolution 3.5 µm columns are your best choice. With all particle sizes, easy method transfer is possible. With more rigorous QA and QC testing, column lot-to-lot reproducibility is also improved, resulting in long-term reliable results for all analyses. Column Specifications Pore Bonded Phase Size ZORBAX Eclipse Plus C18 95Å ZORBAX Eclipse Plus C8 95Å ZORBAX Eclipse PAH 95Å ZORBAX Eclipse Plus 95Å Phenyl-Hexyl Surface Area 160 m2/g 160 m2/g 160 m2/g 160 m2/g Temp. Limits 60°C 60°C 60°C 60°C pH Range* 2.0-9.0 2.0-9.0 2.0-8.0 2.0-8.0 Endcapped Double Double No Double Carbon Load 9% 7% 14% 9% Specifications represent typical values only. *Column lifetime will be reduced significantly at pH >7 and temperature >40°C. At pH 6-9, highest column stability for all silica based columns is obtained by operating at temperatures <40°C and using lower buffer concentrations in range of 0.01-0.02 M, especially with phosphate and carbonate buffers. LC AND LC/MS COLUMNS 827 Columns for Analytical HPLC ZORBAX Eclipse Plus: Best Peak Shape in the Industry Without Tailing Column: Eclipse Plus C18 959996-902 4.6 x 100 mm, 5 µm Mobile Phase: A: 60% Water B: 40% Acetonitrile 1.0 mL/min Ambient UV 254 nm 5989-4934EN Pyridine, Phenol Flow Rate: Temperature: Detector: Publication: Sample: 1 1. Pyridine 2. Phenol 2 Eclipse Plus C18 Ace 5 C18 SunFire C18 XBridge C18 Discovery HS C18 Luna C18 (2) Gemini C18 XTerra MS C18 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Time (min) LCEC001 Peak Shape and Efficiency are Better with ZORBAX Eclipse Plus Column A: Column B: XBridge C18, 4.6 x 150 mm, 5 µm Eclipse Plus C18 959993-902 A 4.6 x 150 mm, 5 µm Mobile Phase: A: 0.1% formic acid B: 0.1% formic acid in ACN 1.0 mL/min 0.0 min 10% B 15 min 30% B 40°C UV 254 nm 5989-4934EN Sulfonamides Flow Rate: Gradient: Temperature: Detector: Publication: Sample: 1 N = 14000 Tf = 1.25 3 2 0 2 B 1 828 LC AND LC/MS 2 5 4 4 6 Time (min) 4 www.agilent.com/chem/lccolumns www.crawfordscientific.com 1. 2. 3. 4. 5. 6. 6 8 10 N = 23000 Tf = 1.01 2 0 N = 41000 Tf = 1.13 12 N = 60000 Tf = 1.00 3 4 6 Time (min) 6 5 8 l 01357 522 961 10 12 LCEC003 Sulfanilamide Sulfadiazine Sulfathiazole Sulfamerazine Sulfmethazine Sulfamethoxazole Columns for Analytical HPLC Eliminate Tailing and Maximize Resolution with Eclipse Plus Columns Column A: Column B: Eclipse Plus C18, 4.6 x 50 mm Competitive C18, 4.6 x 50 mm Mobile Phase: 65% ACN:35% 25 mM phosphate buffer (pH 7.4) 1 Eclipse Plus C18, 4.6 x 50 mm Tf = 1.20 1. Nortriptyline 2. Dipropylthalate Competitive C18, 4.6 x 50 mm 1 Superior peak shape and better selectivity with Eclipse Plus means more resolution, easier quantitation and better results in your separations. Tf = 4.86 2 2 0 0.5 1 1.5 2 min Tips & Tools To learn more about Agilent's complete portfolio of services, please visit www.agilent.com/chem/services LC AND LC/MS COLUMNS 829 Columns for Analytical HPLC ZORBAX Eclipse Plus Hardware Description Analytical Analytical Analytical Analytical Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Solvent Saver Solvent Saver Solvent Saver Plus Solvent Saver Plus Solvent Saver RRHD, 1200 bar Solvent Saver RRHD, 1200 bar Solvent Saver RRHD, 1200 bar Solvent Saver HT, 600 bar Solvent Saver HT, 600 bar Narrow Bore Narrow Bore Narrow Bore Narrow Bore RR Narrow Bore RR Narrow Bore RR Narrow Bore RR Narrow Bore RRHD, 1200 bar Narrow Bore RRHD, 1200 bar Narrow Bore RRHD, 1200 bar Narrow Bore RRHT, 600 bar Narrow Bore RRHT, 600 bar Narrow Bore RRHT, 600 bar Guard Cartridges, 4/pk Guard Cartridges, 4/pk Guard Hardware Kit 830 LC AND LC/MS Size (mm) 4.6 x 250 4.6 x 150 4.6 x 100 4.6 x 50 4.6 x 150 4.6 x 100 4.6 x 75 4.6 x 50 4.6 x 30 4.6 x 100 4.6 x 75 4.6 x 50 4.6 x 30 3.0 x 250 3.0 x 150 3.0 x 150 3.0 x 100 3.0 x 150 3.0 x 100 3.0 x 50 3.0 x 100 3.0 x 50 2.1 x 250 2.1 x 150 2.1 x 50 2.1 x 150 2.1 x 100 2.1 x 50 2.1 x 30 2.1 x 150 2.1 x 100 2.1 x 50 2.1 x 100 2.1 x 50 2.1 x 30 4.6 x 12.5 2.1 x 12.5 Particle Size (µm) 5 5 5 5 3.5 3.5 3.5 3.5 3.5 1.8 1.8 1.8 1.8 5 5 3.5 3.5 1.8 1.8 1.8 1.8 1.8 5 5 5 3.5 3.5 3.5 3.5 1.8 1.8 1.8 1.8 1.8 1.8 5 5 www.agilent.com/chem/lccolumns www.crawfordscientific.com Eclipse Plus C18 USP L1 959990-902 959993-902 959996-902 959946-902 959963-902 959961-902 959933-902 959943-902 959936-902 959964-902 959951-902 959941-902 959931-902 Eclipse Plus C8 USP L7 959990-906 959993-906 959996-906 959946-906 959963-906 959961-906 959933-906 959943-906 959936-906 959964-906 Eclipse Plus Phenyl-Hexyl USP L11 959990-912 959993-912 959996-912 Eclipse PAH USP L1 959990-918 959993-918 959996-918 959963-912 959961-912 959933-912 959943-912 959936-912 959964-912 959963-918 959961-918 959941-906 959931-906 959941-912 959931-912 959941-918 959931-918 959990-318 959993-302 959963-302 959961-302 959759-302 959758-302 959757-302 959964-302 959941-302 959993-306 959963-306 959961-306 959759-306 959758-306 959757-306 959964-306 959941-306 959701-902 959746-902 959763-902 959793-902 959743-902 959733-902 959759-902 959758-902 959757-902 959764-902 959741-902 959731-902 820950-936 821125-936 820999-901 959701-906 959746-906 959763-906 959793-906 959743-906 959733-906 959759-906 959758-906 959757-906 959764-906 959741-906 959731-906 820950-937 821125-937 820999-901 l 01357 522 961 959943-918 959964-918 959963-312 959961-312 959964-312 959941-312 959701-912 959763-912 959793-912 959743-912 959733-912 959764-912 959741-912 959731-912 820950-938 821125-938 820999-901 959790-918 959701-918 959793-918 959764-918 959741-918 820950-939 821125-939 820999-901 Columns for Analytical HPLC ZORBAX Eclipse XDB CH3 O Si CH3 CH3 Si O CH3 CH3 CH3 O Si CH3 CH3 O Si CH3 CH3 CH3 O • Four selectivity choices for method development optimization • Good peak shape for basic, acidic and neutral compounds • High performance over a wide pH range – pH 2-9 • Particle sizes from 1.8 µm to 7 µm • Long lifetime with extra dense bonding and double endcapping Si CH3 eXtra Densely Bonded and Double Endcapped Eclipse XDB Bonded Phase Agilent ZORBAX Eclipse XDB columns – C18, C8, Phenyl and CN – provide four bonded phase choices for method development optimization. These columns provide good peak shape over a wide pH range (2-9) for additional method development flexibility with one family of columns. Eclipse XDB columns can be used for method development at low pH (2-3) and the same column can be used for method development in the mid pH (6-8) region. In the mid pH region residual silanols are more active and tailing interactions are more likely. To overcome these interactions, Eclipse XDB columns are eXtra Densely Bonded and double endcapped through a proprietary process to cover as many active silanols as possible. The result is superior peak shape of basic compounds from pH 2-9. Eclipse XDB columns are available in 1.8, 3.5, 5 and 7 µm particle sizes for high speed, high resolution, analytical and prep scale separations. Column Specifications Bonded Phase ZORBAX Eclipse XDB-C18 ZORBAX Eclipse XDB-C8 ZORBAX Eclipse XDB-Phenyl ZORBAX Eclipse XDB-CN Pore Size 80Å 80Å 80Å 80Å Temp. pH Carbon Surface Area Limits Range* Endcapped Load 60°C 2.0-9.0 Double 10% 180 m2/g 60°C 2.0-9.0 Double 7.6% 180 m2/g 60°C 2.0-9.0 Double 7.2% 180 m2/g 180 m2/g 60°C 2.0-8.0 Double 4.3% Specifications represent typical values only. *Eclipse XDB columns are designed for operation over a wide pH range.At pH 6-9, highest columns stability for all silica based columns is achieved by operating at temperatures <40°C and using low buffer concentrations in the range of 0.01-0.02 M. LC AND LC/MS COLUMNS 831 Columns for Analytical HPLC Good Peak Shape Over a Wide pH Range with ZORBAX Eclipse XDB Column: Mobile Phase: Flow Rate: Temperature: Eclipse XDB-C8 993967-906 4.6 x 150 mm, 5 µm A A: pH 3.0 75% 25 mM phosphate buffer 25% ACN B: pH 7.0 90% 20 mM phosphate 10% ACN 1.5 mL/min 40°C ZORBAX Eclipse XDB columns provide good peak shape over a wide pH range and are an excellent choice for method development from pH 2-9. B 2 2 Sample: 3 1 3 4 5 B: 1. Procainamide 2. N-acetylprocainamide 3. N-propionylprocainamide 1 0 2.5 5.0 Time (min) A: 1. Maleate 2. Doxylamine 3. Chlorpheniramine 4. Triprolidine 5. Diphenhydramine 7.5 0 2.5 5.0 Time (min) 7.5 LCEC004 Column Stability Testing at pH 3 and 60°C Column: Mobile Phase: Flow Rate: Temperature: Sample: ZORBAX SB-C8 883975-906 4.6 x 150 mm, 5 µm Eclipse XDB-C8 993967-906 4.6 x 150 mm, 5 µm Purge Conditions: 70% 50 mM NaAc-HCl, pH 3.0 30% ACN Retention Test Conditions: 65% Methanol 35% Water 1.0 mL/min 60°C Tricyclic Antidepressants 7.0 6.5 K of Amitriptyline Column: 6.0 ZORBAX SB-C8 5.5 ZORBAX Eclipse XDB-C8 Competitive C8 5.0 0 2 4 6 8 Column Volumes of Mobile Phase (X1000) 10 12 LCEC005 Eclipse XDB columns are stable over a wide pH range. At low pH an Eclipse endcapped column is extremely stable and shows equivalent stability to a nonendcapped column, SB-C8, at pH 3. The columns were purged with a pH 3 mobile phase at 60°C. Then they were tested with a strongly basic compound to determine if the endcapping or bonded phase had been hydrolyzed from the silica surface. The Eclipse XDB column was very stable, as shown by the consistency of the retention of amitriptyline over the 12,000 column volumes of the test. Another endcapped column shows less stability under these same conditions. 832 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC Column Stability Testing at pH 7.0 Column A: Column B: Mobile Phase: Flow Rate: Temperature: Sample: Competitive C8 SIL-type After 1826 Column Volumes Eclipse XDB-C8 993967-906 4.6 x 150 mm, 5 µm Sol-type After 1843 Column Volumes 60% ACN 40% 250 mM Phosphate Buffer, pH 7.0 1.5 mL/min 60°C Tricyclic Antidepressants A B 1 5 5 1 1. 2. 3. 4. 5. 2, 3 4 Uracil Nortriptyline Doxepin Amitriptyline Trimipramine 2 3 4 0 0 1 2 3 4 5 6 7 8 9 10 11 12 Time (min) 1 2 3 4 5 Time (min) 6 7 8 LCEC006 Double endcapping, dense bonding and the durable Rx-Sil particles (sol-type) combine to provide long lifetime at pH 7 when compared to single endcapped sil-gel columns used here. The conditions used for this test – high temperature (60°C) and high salt concentration (250 mM), accelerate the dissolution of silica, causing premature failure of the sil-gel type column. Selectivity Changes for Basic Compounds with Eclipse XDB and StableBond Column A: Column B: Mobile Phase: Flow Rate: Temperature: A Eclipse XDB-C8 966967-906 4.6 x 75 mm, 3.5 µm ZORBAX Rx/SB-C8 866953-906 4.6 x 75 mm, 3.5 µm 2 1. Barbital 2. Sulfamethoxazole 3. Caffeine 3 70% 25 mM NaH2PO4, pH 3.0 30% Methanol 1.0 mL/min 35°C Eclipse XDB and StableBond columns are based on the same silica but have different bonding and endcapping. Therefore, they can have very different selectivity for the same sample under the same conditions, as this example shows. B 2 3 1 1 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Time (min) 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Time (min) LCEC008 LC AND LC/MS COLUMNS 833 Columns for Analytical HPLC Optimize Separations with Eclipse XDB Selectivity Options: Analysis of Sunscreens Column A: Column B: Column C: Eclipse XDB-Phenyl 963967-912 4.6 x 150 mm, 3.5 µm Eclipse XDB-C8 963967-906 4.6 x 150 mm, 3.5 µm Eclipse XDB-C18 963967-902 4.6 x 150 mm, 3.5 µm A 1 1. Oxybenzone 2. Padimate-O 3. Ethylhexylsalicylate 2 3 Mobile Phase: Flow Rate: Temperature: Sample: 0 B 15% H2O:85% MeOH 1.0 mL/min 35°C Sunscreens 2 4 6 8 10 12 14 16 10 12 14 16 1 2 3 0 C This separation of sunscreens on all three Eclipse XDB bonded phases – C18, C8 and Phenyl – shows that different bonded phases can be used to optimize a separation. While all three bonded phases provide an adequate separation, the Eclipse XDB-Phenyl provides a different peak elution order and a much shorter overall analysis time. All three bonded phases also provide excellent peak shape with no mobile phase additives. 2 4 6 8 1 2 3 0 2 4 6 8 10 Time (min) 12 14 LCEC007 Selectivity for Urea Pesticides Column A: Column B: Column C: Mobile Phase: Flow Rate: Temperature: Sample: Eclipse XDB-C18 993967-902 4.6 x 150 mm, 5 µm Eclipse XDB-CN 993967-905 4.6 x 150 mm, 5 µm Eclipse XDB-C18 993967-902 4.6 x 150 mm, 5 µm A. 60:40 MeOH:Water B. 60:40 MeOH:Water C. 77:23 MeOH:Water 1.0 mL/min 25°C Urea pesticides A 2 3 4 1 5 6 0 10 B 30 Time (min) 40 50 2 34 5 1 0 2 C 2 6 4 6 Time (min) 34 2 8 10 8 10 5 1 0 20 1. 2. 3. 4. 5. 6. Fenuron Monuron MonoLinuron Diuron Linuron Pencycuron 6 4 6 Time (min) The Eclipse XDB-CN column reduces retention time and provides good selectivity for Urea pesticides when compared to an Eclipse XDB-C18 column. 834 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 16 LCEC010 Columns for Analytical HPLC ZORBAX Eclipse XDB Hardware Description Size (mm) Particle Size (µm) Eclipse XDB-C18 USP L1 Eclipse XDB-C8 USP L7 990967-202 990967-902 993967-902 946975-902 963967-902 961967-902 966967-902 935967-902 934967-902 932967-902 928975-902 927975-902 924975-902 926975-902 990967-302 993967-302 963954-302 961967-302 966954-302 981759-302 981758-302 981757-302 928975-302 927975-302 924975-302 926975-302 993700-902 960967-902 930990-902 961753-902 966735-902 971700-902 974700-902 972700-902 981759-902 981758-902 981757-902 990967-206 990967-906 993967-906 946975-906 963967-906 961967-906 966967-906 935967-906 934967-906 932967-906 928975-906 927975-906 924975-906 926975-906 990967-306 993967-306 963954-306 961967-306 Eclipse XDB-Phenyl USP L11 Eclipse XDB-CN USP L10 990967-912 993967-912 990967-905 993967-905 963967-912 963967-905 961967-905 966967-905 Standard Columns (no special hardware required) Semi-Preparative Analytical Analytical Analytical Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Solvent Saver Solvent Saver Solvent Saver Plus Solvent Saver Plus Solvent Saver Plus Solvent Saver RRHD, 1200 bar Solvent Saver RRHD, 1200 bar Solvent Saver RRHD, 1200 bar Solvent Saver HT, 600 bar Solvent Saver HT, 600 bar Solvent Saver HT, 600 bar Solvent Saver HT, 600 bar Narrow Bore Narrow Bore Narrow Bore RR Narrow Bore RR Narrow Bore RR Narrow Bore RR Narrow Bore RR Narrow Bore RR Narrow Bore RRHD, 1200 bar Narrow Bore RRHD, 1200 bar Narrow Bore RRHD, 1200 bar 9.4 x 250 4.6 x 250 4.6 x 150 4.6 x 50 4.6 x 150 4.6 x 100 4.6 x 75 4.6 x 50 4.6 x 30 4.6 x 20 4.6 x 100 4.6 x 50 4.6 x 30 4.6 x 20 3.0 x 250 3.0 x 150 3.0 x 150 3.0 x 100 3.0 x 75 3.0 x 150 3.0 x 100 3.0 x 50 3.0 x 100 3.0 x 50 3.0 x 30 3.0 x 20 2.1 x 150 2.1 x 50 2.1 x 150 2.1 x 100 2.1 x 75 2.1 x 50 2.1 x 30 2.1 x 20 2.1 x 150 2.1 x 100 2.1 x 50 5 5 5 5 3.5 3.5 3.5 3.5 3.5 3.5 1.8 1.8 1.8 1.8 5 5 3.5 3.5 3.5 1.8 1.8 1.8 1.8 1.8 1.8 1.8 5 5 3.5 3.5 3.5 3.5 3.5 3.5 1.8 1.8 1.8 928975-306 927975-306 924975-306 926975-306 993700-906 960967-906 930990-906 961753-906 966967-912 935967-912 990967-312 993967-312 963954-312 961967-312 990967-305 993967-305 963954-305 993700-912 960967-912 993700-905 960967-905 961753-905 971700-906 974700-906 972700-906 (Continued) LC AND LC/MS COLUMNS 835 Columns for Analytical HPLC ZORBAX Eclipse XDB Hardware Description Eclipse XDB-C18 USP L1 Eclipse XDB-C8 USP L7 Eclipse XDB-Phenyl USP L11 Eclipse XDB-CN USP L10 1.8 1.8 1.8 1.8 3.5 3.5 3.5 5 5 5 928700-902 927700-902 924700-902 926700-902 963600-902 965600-902 961600-902 5185-5921 820950-925 821125-926 820999-901 928700-906 927700-906 924700-906 926700-906 963600-906 965600-906 961600-906 5185-5921 820950-926 821125-926 820999-901 820950-927 821125-926 820999-901 820950-935 821125-935 820999-901 Size (mm) Particle Size (µm) Standard Columns (no special hardware required) Narrow Bore RRHT, 600 bar Narrow Bore RRHT, 600 bar Narrow Bore RRHT, 600 bar Narrow Bore RRHT, 600 bar MicroBore RR MicroBore RR MicroBore RR MicroBore Guard, 3/pk Guard Cartridges, 4/pk Guard Cartridges, 4/pk Guard Hardware Kit 2.1 x 100 2.1 x 50 2.1 x 30 2.1 x 20 1.0 x 150 1.0 x 50 1.0 x 30 1.0 x 17 4.6 x 12.5 2.1 x 12.5 PrepHT Cartridge Columns (require endfittings kit 820400-901) PrepHT Cartridge 21.2 x 250 7 977250-102 977250-106 PrepHT Cartridge 21.2 x 150 7 977150-102 977150-106 PrepHT Cartridge 21.2 x 150 5 970150-902 970150-906 PrepHT Cartridge 21.2 x 100 5 970100-902 970100-906 PrepHT Cartridge 21.2 x 50 5 970050-902 970050-906 PrepHT Guard Cartridge 17 x 7.5 5 820212-925 820212-926 Guard Cartridge Hardware 820444-901 820444-901 PrepHT endfittings, 2/pk 820400-901 820400-901 Unless indicated, column pressure limit is 400 bar. ZORBAX Eclipse XDB Size (mm) Particle Size (µm) Eclipse XDB-C18 USP L1 Eclipse XDB-C8 USP L7 Analytical 4.6 x 250 5 7995118-585 7995108-585 Analytical 4.6 x 150 5 7995118-595 7995108-595 Rapid Resolution 4.6 x 75 3.5 7995118-344 7995108-344 Solvent Saver Plus 3.0 x 75 3.5 7995230-344 Guard Cartridges, 10/pk Cartridge Holder, 5021-1845 4.0 x 4 5 7995118-504 5021-1845 Hardware Description Agilent Cartridge Columns (require hardware kit 5021-1845) 7995118-504 5021-1845 (Continued) 836 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC ZORBAX Eclipse XDB Size (mm) Particle Size (µm) Eclipse XDB-C18 USP L1 Eclipse XDB-C8 USP L7 4.6 x 50 4.6 x 50 2.1 x 50 2.1 x 50 1.8 1.8 1.8 1.8 922975-902 922975-932 922700-902 922700-932 922975-906 Rapid Resolution Cartridge 4.6 x 30 3.5 933975-902 933975-906 Rapid Resolution Cartridge, 3/pk 4.6 x 30 3.5 933975-932 933975-936 Rapid Resolution Cartridge 4.6 x 15 3.5 931975-902 931975-906 Rapid Resolution Cartridge, 3/pk 4.6 x 15 3.5 931975-932 931975-936 Rapid Resolution Cartridge 2.1 x 30 3.5 973700-902 973700-906 Rapid Resolution Cartridge, 3/pk 2.1 x 30 3.5 973700-932 973700-936 Rapid Resolution Cartridge 2.1 x 15 3.5 975700-902 975700-906 Rapid Resolution Cartridge, 3/pk 2.1 x 15 3.5 975700-932 975700-936 Rapid Resolution HT Cartridge 4.6 x 50 1.8 925975-902 Rapid Resolution HT Cartridge, 3/pk 4.6 x 50 1.8 925975-932 Rapid Resolution HT Cartridge 4.6 x 30 1.8 923975-902 Rapid Resolution HT Cartridge, 3/pk 4.6 x 30 1.8 923975-932 Rapid Resolution HT Cartridge 4.6 x 15 1.8 921975-902 Rapid Resolution HT Cartridge, 3/pk 4.6 x 15 1.8 921975-932 Rapid Resolution HT Cartridge 2.1 x 50 1.8 925700-902 Rapid Resolution HT Cartridge, 3/pk 2.1 x 50 1.8 925700-932 Rapid Resolution HT Cartridge 2.1 x 30 1.8 923700-902 Rapid Resolution HT Cartridge, 3/pk 2.1 x 30 1.8 923700-932 Rapid Resolution HT Cartridge 2.1 x 15 1.8 921700-902 Rapid Resolution HT Cartridge, 3/pk 2.1 x 15 1.8 Hardware Description Standard Columns (no special hardware required) Rapid Resolution HT Rapid Resolution HT, 3/pk Narrow Bore RRHT Narrow Bore RRHT, 3/pk Rapid Resolution HT Cartridges (require hardware kit 820555-901) Hardware Kit for RR and RRHT Cartridges 921700-932 820555-901 Capillary Glass-lined Columns Capillary Capillary Capillary RR Capillary RR Capillary Capillary Capillary RR Capillary Capillary 0.5 x 250 0.5 x 150 0.5 x 150 0.5 x 35 0.3 x 250 0.3 x 150 0.3 x 150 0.5 x 35 0.3 x 35 5 5 3.5 3.5 5 5 3.5 5 5 5064-8286 5064-8287 5064-8288 5064-8298 5064-8269 5064-8291 5064-8271 5064-8296 5064-8297 LC AND LC/MS COLUMNS 837 Columns for Analytical HPLC ZORBAX 80Å StableBond R O Si R1 without degradation • Six different bonded phases provide broad selectivity – SB-C18, SB-C8, SB-CN, SB-Phenyl, SB-C3, and SB-Aq • High purity (Type B) silica for good peak shape R OH R O Si R1 R OH R O Si • Longest column lifetime and best reproducibility for low pH separations – down to pH 1 • Patented stable column chemistry allows use at high temperature and low pH R1 R Agilent ZORBAX StableBond columns use patented, unique, nonfunctional silanes with bulky diisobutyl (SB-C18) or diisopropyl (SB-C8, SB-C3, SB-Phenyl, SB-CN, and SB-Aq) side chain groups that sterically protect the key siloxane bond to the silica surface from hydrolytic attack at low pH. StableBond packing materials are not endcapped in order to provide exceptional stability and to maximize lifetime and reproducibility under acidic mobile phase conditions. The high purity, low acidity silica provides excellent peak shape with acidic, basic and neutral compounds making StableBond columns an excellent choice for low pH method development. ZORBAX StableBond columns are compatible with all common mobile phases, including very high aqueous mobile phases. Column Specifications Sterically Protected StableBond Bonded Phase Bonded Phase ZORBAX SB-C18 ZORBAX SB-C8 ZORBAX SB-C3 ZORBAX SB-Phenyl ZORBAX SB-CN ZORBAX SB-Aq Pore Size 80Å 80Å 80Å 80Å 80Å 80Å Surface Area 180 m2/g 180 m2/g 180 m2/g 180 m2/g 180 m2/g 180 m2/g Temp. Limits* 90°C 80°C 80°C 80°C 80°C 80°C pH Range* Endcapped 0.8-8.0 No 1.0-8.0 No 1.0-8.0 No 1.0-8.0 No 1.0-8.0 No 1.0-8.0 No Carbon Load 10% 5.5% 4% 5.5% 4% proprietary Specifications represent typical values only. *StableBond columns are designed for optimal use at low pH. At pH 6-8, highest column stability for all silica-based columns is obtained by operating at temperatures <40°C and using lower buffer concentrations in the range of 0.01-0.02 M. At mid-range pH, Eclipse Plus, Eclipse XDB and Bonus-RP are recommended. 838 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC StableBond SB-C18 Shows Excellent Stability at Low pH and High Temperature (pH 0.8, 90°C) Column: Column: Mobile Phase: Temperature: ZORBAX SB-C18 883975-902 4.6 x 150 mm, 5 µm ZORBAX Rx-C18 883967-902 4.6 x 150 mm, 5 µm As an indicator of column breakdown, retention time of toluene was measured after purging the column with mobile phase. Only the StableBond SB-C18 is unchanged after three working months of use under these very low pH (0.8) and high temperature (90°C) conditions. ZORBAX Rx-C18 also provides a stable matrix, and can be used as an alternative selectivity to StableBond SB-C18. 50% Methanol/50% Water with 1.0% TFA Test Solute: Toluene 90°C StableBond SB-C18 (Diisobutyl-C18) Relative Retention 1.0 ZORBAX Rx-C18 (Dimethyl-C18) 0.8 Competitor A-C18 0.6 Competitor B-C18 Competitor C-C18 0.4 Competitor D-C18 0.2 Competitor E-C18 0.0 0 5,000 10,000 15,000 20,000 25,000 30,000 Column Volumes of Mobile Phase Purge LCSB001 Shorter Chain ZORBAX SB-CN is also Stable at Low pH (pH 2.0, 50°C) ZORBAX SB-CN 883975-905 4.6 x 150 mm, 5 µm Mobile Phase: Flow Rate: Gradient: Temperature: Sample: 0.1% TFA, pH 2:ACN 1 mL/min 0-100% ACN 50°C 1-phenylheptane @ 50% AC/50% Water with 0.1% TFA SB-CN 100 80 % k Remaining Column: 60 40 Si-(Me)2PrCN 20 ZORBAX StableBond SB-CN and other short chain StableBond bonded phases are also exceptionally stable at low pH. Conventional dimethyl CN and similar bonded phases lack this stability. 0 0 1,000 2,000 3,000 4,000 5,000 6,000 Column Volumes LCSB002 LC AND LC/MS COLUMNS 839 Columns for Analytical HPLC SB-CN Optimizes Retention and Resolution Column A: Column B: Mobile Phase: Flow Rate: Temperature: ZORBAX SB-C18 866953-902 4.6 x 75 mm, 3.5 µm ZORBAX SB-CN 866953-905 4.6 x 75 mm, 3.5 µm 1. 2. 3. 4. 5. A 2 30% ACN 70% 25mM NaH2PO4, pH 2.5 1.0 mL/min 35°C Estriol Daidzen Quercetin Genistein Diethylstilbestrol B 5 1 4 2 3 4 5 1 The SB-CN column is used here to reduce analysis time by 50%. The retention of the most hydrophobic analyte is cut in half. At the same time retention of the more polar, early eluting peaks increases slightly. 0 5 10 15 Time (min) 20 25 0 3 2 4 6 8 10 Time (min) 12 LCSB003 Five Different Bonded Phases Provide Selectivity Options Column A: Column B: Column C: Column D: Column E: Mobile Phase: Flow Rate: Temperature: Detector: Sample: ZORBAX SB-C18 883975-902 4.6 x 150 mm, 5 µm ZORBAX SB-C8 883975-906 4.6 x 150 mm, 5 µm ZORBAX SB-C3 883975-909 4.6 x 150 mm, 5 µm ZORBAX SB-Phenyl 883975-912 4.6 x 150 mm, 5 µm ZORBAX SB-CN 883975-905 4.6 x 150 mm, 5 µm 0-100% B in 18.8 min A: 50 mM NaH2PO4, pH 2.5 in 95% H2O / 5% ACN B: 50 mM NaH2PO4, pH 2.5 in 47% H2O / 53% ACN 1.0 mL/min 26°C 254 nm 1. Procaine 2. Lidocaine 3. d-Cinchonine 4. Butacaine 5. Tetracaine SB-C3 is just one of the five different StableBond selectivity choices. In this example, optimum resolution is obtained with SB-C3. All are based on the same high purity Rx-SIL. Selectivity changes are therefore dependent only on the bonded phases, making method development more reliable. A 3 1 5 4 2 3 B 1 5 4 2 3 C 1 5 4 2 3 D 1 5 4 2 E 13 5 4 2 0 5 10 15 Time (min) LCSB004 840 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC ZORBAX 80Å StableBond Hardware Description Size (mm) Particle Size SB-C18 (µm) USP L1 SB-C8 USP L7 SB-CN USP L10 SB-C3 USP L56 SB-Phenyl USP L11 SB-Aq Standard Columns (no special hardware required) Semi-Preparative Semi-Preparative Semi-Preparative Semi-Preparative Analytical Analytical Analytical Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Solvent Saver Solvent Saver Solvent Saver Plus Solvent Saver Plus Solvent Saver Plus 9.4 x 250 9.4 x 150 9.4 x 100 9.4 x 50 4.6 x 250 4.6 x 150 4.6 x 50 4.6 x 250 4.6 x 150 4.6 x 100 4.6 x 75 4.6 x 50 4.6 x 30 4.6 x 20 4.6 x 150 5 5 5 5 5 5 5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 1.8 880975-202 883975-202 884975-202 846975-202 880975-902 883975-902 846975-902 884950-567 863953-902 861953-902 866953-902 835975-902 834975-902 832975-902 829975-902 4.6 x 100 880967-201 880975-205 880975-209 880975-212 880975-906 880975-905 880975-909 880975-912 880975-914 883975-906 883975-905 883975-909 883975-912 883975-914 846975-906 846975-914 863953-906 861953-906 866953-906 835975-906 834975-906 832975-906 829975-906 863953-905 861953-905 866953-905 835975-905 863953-912 861953-912 866953-912 835975-912 829975-905 829975-912 829975-914 1.8 828975-902 828975-906 828975-905 828975-912 828975-914 4.6 x 50 1.8 827975-901 827975-906 827975-905 827975-912 827975-914 4.6 x 30 1.8 824975-902 824975-906 824975-905 824975-912 824975-914 4.6 x 20 1.8 826975-902 826975-906 3.0 x 250 3.0 x 150 3.0 x 150 3.0 x 100 3.0 x 75 5 5 3.5 3.5 3.5 880975-302 883975-302 863954-302 861954-302 866953-302 880975-306 883975-306 863954-306 861954-306 863953-914 861953-914 866953-914 835975-914 880975-305 880975-309 880975-312 880975-314 883975-305 883975-309 883975-312 883975-314 863954-305 863954-312 863954-314 861954-305 861954-309 861954-312 861954-314 Unless indicated, column pressure limit is 400 bar. (Continued) LC AND LC/MS COLUMNS 841 Columns for Analytical HPLC ZORBAX 80Å StableBond Hardware Description Size (mm) Particle Size SB-C18 (µm) USP L1 SB-C8 USP L7 SB-CN USP L10 SB-C3 USP L56 SB-Phenyl USP L11 SB-Aq Standard Columns (no special hardware required) Solvent Saver RRHD, 1200 bar Solvent Saver RRHD, 1200 bar Solvent Saver RRHD, 1200 bar Solvent Saver HT, 600 bar Solvent Saver HT, 600 bar Solvent Saver HT, 600 bar Solvent Saver HT, 600 bar Solvent Saver HT, 600 bar Narrow Bore Narrow Bore Narrow Bore RR Narrow Bore RR Narrow Bore RR Narrow Bore RR Narrow Bore RR Narrow Bore RR Narrow Bore RRHD, 1200 bar Narrow Bore RRHD, 1200 bar Narrow Bore RRHD, 1200 bar 3.0 x 150 1.8 859700-302 859700-306 3.0 x 100 1.8 858700-302 858700-306 858700-305 858700-312 3.0 x 50 1.8 857700-302 857700-306 857700-305 857700-312 3.0 x 150 1.8 829975-302 829975-306 829975-305 829975-312 3.0 x 100 1.8 828975-302 828975-306 828975-305 828975-309 828975-312 828975-314 3.0 x 50 1.8 827975-302 827975-306 827975-305 3.0 x 30 1.8 824975-302 824975-306 824975-305 3.0 x 20 1.8 826975-302 826975-306 2.1 x 150 2.1 x 50 2.1 x 150 2.1 x 100 2.1 x 75 2.1 x 50 2.1 x 30 2.1 x 20 2.1 x 150 5 5 3.5 3.5 3.5 3.5 3.5 3.5 1.8 883700-922 860975-902 830990-902 861753-902 866735-902 871700-902 874700-902 872700-902 859700-902 871700-906 874700-906 872700-906 859700-906 859700-905 859700-912 2.1 x 100 1.8 858700-902 858700-906 858700-905 858700-912 2.1 x 50 1.8 857700-902 857700-906 857700-905 857700-912 827975-312 827975-314 883700-906 883700-905 883700-909 883700-912 860975-906 860975-905 860975-909 860975-912 860975-914 830990-906 830990-914 861753-906 861753-905 861753-912 861753-914 871700-914 Unless indicated, column pressure limit is 400 bar. (Continued) 842 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC ZORBAX 80Å StableBond Hardware Description Size (mm) Particle Size SB-C18 (µm) USP L1 SB-C8 USP L7 SB-CN USP L10 SB-C3 USP L56 SB-Phenyl USP L11 SB-Aq Standard Columns (no special hardware required) Narrow Bore RRHT, 600 bar Narrow Bore RRHT, 600 bar Narrow Bore RRHT, 600 bar Narrow Bore RRHT, 600 bar Narrow Bore RRHT, 600 bar MicroBore RR MicroBore RR MicroBore RR MicroBore Guard, 3/pk Guard Cartridge, 2/pk Guard Cartridge, 4/pk Guard Cartridge, 4/pk Guard Hardware Kit Guard Hardware Kit 2.1 x 150 1.8 820700-902 820700-906 820700-905 820700-912 2.1 x 100 1.8 828700-902 828700-906 828700-905 828700-912 828700-914 2.1 x 50 1.8 827700-902 827700-906 827700-905 827700-912 827700-914 2.1 x 30 1.8 824700-902 824700-906 824700-905 824700-912 824700-914 2.1 x 20 1.8 826700-902 826700-906 1.0 x 150 1.0 x 50 1.0 x 30 1.0 x 17 9.4 x 15 4.6 x 12.5 2.1 x 12.5 9.4 x 15 3.5 3.5 3.5 5 7 5 5 0 863600-902 865600-902 861600-902 5185-5920 820675-115 820950-920 821125-915 840140-901 820999-901 863600-906 865600-906 861600-906 5185-5920 820675-115 820950-915 821125-915 840140-901 820999-901 863600-905 820675-124 820950-916 821125-924 840140-901 820999-901 820675-124 820950-922 821125-924 840140-901 820999-901 820675-115 820950-917 820950-933 821125-915 821125-933 840140-901 820999-901 820999-901 PrepHT Cartridge Columns (require endfittings kit 820400-901) PrepHT Cartridge 21.2 x 250 7 877250-102 877250-106 877250-105 877250-112 877250-114 PrepHT Cartridge 21.2 x 150 7 877150-102 877150-106 877150-114 PrepHT Cartridge 21.2 x 150 5 870150-902 870150-906 870150-914 PrepHT Cartridge 21.2 x 100 5 870100-902 870100-906 870100-914 PrepHT Cartridge 21.2 x 50 5 870050-902 870050-906 870050-914 PrepHT Guard Cartridge, 2/pk Guard Cartridge Hardware PrepHT endfittings, 2/pk 17 x 7.5 5 820212-920 820212-915 820212-915 820212-915 820212-933 820444-901 820444-901 820444-901 820444-901 820444-901 820444-901 820400-901 820400-901 820400-901 820400-901 820400-901 820400-901 Unless indicated, column pressure limit is 400 bar. LC AND LC/MS COLUMNS 843 Columns for Analytical HPLC ZORBAX 80Å StableBond Hardware Description Size (mm) Particle Size (µm) SB-C18 USP L1 SB-C8 USP L7 SB-Phenyl USP L11 Agilent Cartridge Columns (require hardware kit 5021-1845) Analytical 4.6 x 250 5 7995218-585 7995208-585 Analytical 4.6 x 150 5 7995218-595 7995208-595 Rapid Resolution 4.6 x 75 3.5 7995218-344 7995208-344 Guard Cartridges, 10/pk 4.0 x 4 5 7995118-504 7995118-504 5021-1845 5021-1845 822975-906 Cartridge Holder, 5021-1845 Standard Columns (no special hardware required) Rapid Resolution HT 4.6 x 50 1.8 822975-902 Rapid Resolution HT, 3/pk 4.6 x 50 1.8 822975-932 Narrow Bore RRHT 2.1 x 50 1.8 822700-902 Narrow Bore RRHT, 3/pk 2.1 x 50 1.8 822700-932 Rapid Resolution Cartridges (require hardware kit 820555-901) Rapid Resolution Cartridge 4.6 x 30 3.5 833975-902 833975-906 Rapid Resolution Cartridge, 3/pk 4.6 x 30 3.5 833975-932 833975-936 Rapid Resolution Cartridge 4.6 x 15 3.5 831975-902 831975-906 Rapid Resolution Cartridge, 3/pk 4.6 x 15 3.5 831975-932 831975-936 Rapid Resolution Cartridge 2.1 x 30 3.5 873700-902 873700-906 Rapid Resolution Cartridge, 3/pk 2.1 x 30 3.5 873700-932 873700-936 Rapid Resolution Cartridge 2.1 x 15 3.5 875700-902 875700-906 Rapid Resolution Cartridge, 3/pk 2.1 x 15 3.5 875700-932 875700-936 833975-912 (Continued) Tips & Tools More information is a click away. We have a variety of educational primers, application notes, maintenance guides, and literature available from Agilent for free. To learn more, visit www.agilent.com/chem/OnlineLibrary 844 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC ZORBAX 80Å StableBond Hardware Description Size (mm) Particle Size (µm) SB-C18 USP L1 SB-C8 USP L7 SB-Phenyl USP L11 Rapid Resolution HT Cartridges (require hardware kit 820555-901) Rapid Resolution HT Cartridge 4.6 x 50 1.8 825975-902 Rapid Resolution HT Cartridge, 3/pk 4.6 x 50 1.8 825975-932 Rapid Resolution HT Cartridge 4.6 x 30 1.8 823975-902 Rapid Resolution HT Cartridge, 3/pk 4.6 x 30 1.8 823975-932 Rapid Resolution HT Cartridge 4.6 x 15 1.8 821975-902 Rapid Resolution HT Cartridge, 3/pk 4.6 x 15 1.8 821975-932 Rapid Resolution HT Cartridge 2.1 x 50 1.8 825700-902 Rapid Resolution HT Cartridge, 3/pk 2.1 x 50 1.8 825700-932 Rapid Resolution HT Cartridge 2.1 x 30 1.8 823700-902 Rapid Resolution HT Cartridge, 3/pk 2.1 x 30 1.8 823700-932 Rapid Resolution HT Cartridge 2.1 x 15 1.8 821700-902 Rapid Resolution HT Cartridge, 3/pk 2.1 x 15 1.8 821700-932 Hardware Kit for RR and RRHT Cartridges 820555-901 ZORBAX 80Å StableBond Description Size (mm) Particle Size (µm) SB-C18 USP L1 Capillary Glass-lined Columns Capillary Capillary Capillary Capillary RR Capillary RR Capillary Capillary Capillary Capillary RR 0.5 x 250 0.5 x 150 0.5 x 35 0.5 x 150 0.5 x 35 0.3 x 250 0.3 x 150 0.3 x 35 0.3 x 150 5 5 5 3.5 3.5 5 5 5 3.5 5064-8258 5064-8256 5064-8254 5064-8262 5064-8260 5064-8257 5064-8255 5064-8253 5064-8261 LC AND LC/MS COLUMNS 845 Columns for Analytical HPLC ZORBAX Bonus-RP R1 O PG Si R R1 CH3 Si CH3 O CH3 R1 PG Si R R1 CH3 Si CH3 The Agilent ZORBAX Bonus-RP column has a polar amide group embedded in a long alkyl chain. This novel bonding reduces interactions between basic compounds and the silica support, improving peak shape for the most difficult basic compounds. Peak shape and column lifetime are further improved by triple endcapping. In addition, diisopropyl side groups provide steric protection against acid hydrolysis for good lifetime at low pH. The Bonus-RP column provides an alternate selectivity to C18 and C8 alkyl bonded phases. Column Specifications CH3 R1 O • Excellent peak shape for challenging basic compounds at low and mid pH • Unique reversed-phase selectivity • Novel bonding technology with embedded polar group and steric protection • Usable in 100% aqueous mobile phases Si PG R Bonded Phase ZORBAX Bonus-RP Pore Size 80Å Surface Area 180 m2/g Temp. Limits* 60°C pH Range 2.0-9.0 Endcapped Triple Carbon Load 9.5% Specifications represent typical values only. R1 *Temperature limits are 60°C up to pH 8, 40°C from pH 8-9. Unique, Polar Alkyl Bonus-RP Bonded Phase Improved Peak Shape of Basic Compounds Using Bonus-RP Column: Mobile Phase: Flow Rate: Temperature: Detector: 1 Alkyl-C8 4.6 x 150 mm, 5 µm 2 TF 1. 1.8 2. 1.7 3. 2.1 75% 25 mM NH4OAc, pH 5.5 25% ACN 1.5 mL/min 40°C 254 nm 0 Column: ZORBAX Bonus-RP 883668-901 4.6 x 150 mm, 5 µm Mobile Phase: 80% 25 mM NH4OAc, pH 5.5 20% ACN 1.5 mL/min 40°C 254 nm Flow Rate: Temperature: Detector: LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com 3 2 3 4 5 6 Time (min) 7 8 9 10 LCBR001 3 TF 1. 1.1 2. 1.1 3. 1.1 Bonus-RP eliminates peak tailing of these basic compounds in comparison to a typical alkyl C8 bonded phase. In the mid-pH region, residual silanols can interact more strongly with basic compounds to cause peak tailing. The polar group in the Bonus-RP bonded phase eliminates peak tailing of these basic compounds by reducing interactions with residual silanols. 846 1 1. Doxylamine 2. Chlorpheniramine 3. Triprolidine 0 1. Doxylamine 2. Chlorpheniramine 3. Triprolidine 1 2 1 2 l 01357 522 961 3 4 Time (min) 5 6 LCBR002 Columns for Analytical HPLC Column: ZORBAX Bonus-RP 883668-901 4.6 x 150 mm, 5 µm Mobile Phase: 60% 25 mM Phosphate Buffer, pH 7.0:40% ACN 1.5 mL/min 23°C Flow Rate: Temperature: 0.0018 Toluene Plate Height, cm ZORBAX Bonus-RP is Stable at Low and Mid pH Competitive alkyl/amide Bonus-RP 0.0016 0.0014 0.0012 0.0010 0 5,000 10,000 15,000 20,000 25,000 30,000 35,000 Column Volume of Purge LCBR003 Triple endcapping of Bonus-RP enhances stability at pH 7. Each 10,000 column volume is equivalent to approximately one working month. Dimethyl-C18/amide, Bonus-RP ZORBAX Bonus-RP 883668-901 4.6 x 150 mm, 5 µm Mobile Phase: Aging: 50% MeOH 50% 0.1% TFA Test: 80% MeOH 20% H2O 1.0 mL/min Aging: 60°C Test: 23°C Flow Rate: Temperature: 0.0055 Dimethyl-C18/amide Bonus-RP 0.0050 Toluene Plate Height, cm Column: 0.0045 0.0040 0.0035 0.0030 0.0025 0.0020 0 10,000 20,000 30,000 40,000 Column Volume of Purge LCBR004 Sterically protecting side groups provide good low pH stability and longer column lifetime than similar polar alkyl bonded phases. Tips & Tools Don't forget, we have special offers throughout the year. To learn more, visit www.agilent.com/chem/specialoffers LC AND LC/MS COLUMNS 847 Columns for Analytical HPLC ZORBAX Bonus-RP Provides Unique Selectivity Column A: Column B: Mobile Phase: Flow Rate: Temperature: Detector: Sample: ZORBAX Bonus-RP 883668-901 4.6 x 150 mm, 5 µm Eclipse XDB-C8 993967-906 4.6 x 150 mm, 5 µm 1. 2. 3. 4. A 1 mAu 15 10 75% 25 mM Na Citrate, pH 6 25% MeOH 1.0 mL/min Ambient 254 nm 3 µL Cephalosporins Cephalexin Cephaclor Cephuroxime Cephoxitin 3 5 2 4 0 0 2 4 6 8 10 Time (min) B 1 mAu Peak elution order can change dramatically when using Bonus-RP. In this example, the elution order of the first three peaks changes. 15 3 10 4 5 2 0 0 2 4 6 8 10 Time (min) LCBR005 ZORBAX Bonus-RP Hardware Description Particle Size (mm) Size (µm) Bonus-RP USP L60 Standard Columns (no special hardware required) Analytical Analytical Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar 4.6 x 250 4.6 x 150 4.6 x 250 4.6 x 150 4.6 x 100 4.6 x 75 4.6 x 50 4.6 x 100 4.6 x 75 4.6 x 50 5 5 3.5 3.5 3.5 3.5 3.5 1.8 1.8 1.8 880668-901 883668-901 884950-577 863668-901 864668-901 866668-901 835668-901 828668-901 830668-901 827668-901 Unless indicated, column pressure limit is 400 bar. (Continued) 848 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC ZORBAX Bonus-RP Hardware Description Particle Size (mm) Size (µm) Bonus-RP USP L60 3.0 x 250 3.0 x 150 3.0 x 150 3.0 x 100 3.0 x 100 3.0 x 50 2.1 x 150 2.1 x 50 2.1 x 150 2.1 x 100 2.1 x 50 2.1 x 100 2.1 x 50 1.0 x 150 1.0 x 50 1.0 x 30 1.0 x 17 4.6 x 12.5 2.1 x 12.5 5 5 3.5 3.5 1.8 1.8 5 5 3.5 3.5 3.5 1.8 1.8 3.5 3.5 3.5 5 5 5 880668-301 883668-301 863668-301 864668-301 828668-301 827668-301 883725-901 861971-901 863700-901 861768-901 861700-901 828768-901 827768-901 863608-901 865608-901 861608-901 5185-5922 820950-928 821125-928 820999-901 Standard Columns (no special hardware required) Solvent Saver Solvent Saver Solvent Saver Plus Solvent Saver Plus Solvent Saver HT, 600 bar Solvent Saver HT, 600 bar Narrow Bore Narrow Bore Narrow Bore RR Narrow Bore RR Narrow Bore RR Narrow Bore RRHT, 600 bar Narrow Bore RRHT, 600 bar MicroBore RR MicroBore RR MicroBore RR MicroBore Guard, 3/pk Guard Cartridge, 4/pk Guard Cartridge, 4/pk Guard Hardware Kit PrepHT Cartridge Columns (require endfittings kit 820400-901) PrepHT Cartridge 21.2 x 250 7 878250-101 PrepHT Cartridge 21.2 x 150 7 878150-101 PrepHT Cartridge 21.2 x 150 5 868150-901 PrepHT Cartridge 21.2 x 100 5 868100-901 PrepHT Cartridge 21.2 x 50 5 868050-901 17 x 7.5 5 PrepHT endfittings, 2/pk PrepHT Guard Cartridge, 2/pk Guard Cartridge Hardware 820400-901 820212-928 820444-901 Unless indicated, column pressure limit is 400 bar. LC AND LC/MS COLUMNS 849 Columns for Analytical HPLC ZORBAX 80Å Extend-C18 O O C18 Si Si C18 Silica Support Novel Bidentate C18-C18 Bonding for Extend C-18 Bonded Phase • High efficiency and long life at high pH – up to pH 11.5 • Unique bidentate bonding and double endcapping provides high pH stability • More efficiency and better peak shape than polymer-based columns • Improve retention, resolution and peak shape of basic compounds • High sensitivity for LC/MS separations of peptides The Agilent ZORBAX Extend-C18 column uses a novel bidentate C18-C18 bonding technology to make it possible to develop high-resolution separations at high pH with a silica-based column. At high pH, non-charged basic compounds will not interact with the underlying silica. The result is high efficiency separations with superior peak shape and improved resolution. High pH separations are also the best choice for compounds that are more stable or more soluble in high pH solutions. Some of the mobile phase buffer options for high pH include triethylamine, pyrrolidine, glycine, borate and ammonium hydroxide. Ammonium hydroxide at pH 10.5 is an excellent mobile phase modifier for the LC/MS of peptides and small molecules with improved sensitivity compared with TFA containing mobile phase at low pH. The Extend-C18 column is stable from pH 2-11.5 with good peak shape for all types of compounds. Extend-C18 columns also provide an additional selectivity choice at low pH. Column Specifications Bonded Phase ZORBAX Extend-C18 Pore Size 80Å Surface Area 180 m2/g Temp. Limits* 60°C pH Range** 2.0-11.5 Endcapped Double Carbon Load 12.5% Specifications represent typical values only. *Temperature limits are 60°C up to pH 8, 40°C from pH 8-11.5. **Above pH 6 highest column stability for all silica based columns is obtained by reducing the operating temperature to 40°C or below and using lower buffer concentrations (0.01-0.02 M) or organic buffers. 850 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC Basic Antihistamines on Extend-C18 at High pH Column: Mobile Phase: Flow Rate: Temperature: Detector: Sample: pH 7 ZORBAX Extend-C18 773450-902 4.6 x 150 mm, 5 µm 7 4 1. 2. 3. 4. 5. 6. 7. 2, 3 1 pH 7: 30% 20 mM Na2HPO4 70% MeOH pH 11: 30% 20 mM TEA 70% MeOH 1.0 mL/min Ambient 254 nm Antihistamines 5 6 0 Maleate Scopolamine Pseudoephedrine Doxylamine Chlorpheniramine Triprolidine Diphenhydramine 5 Time (min) 7 pH 11 4 3 5 1 Pseudoephedrine and scopolamine are difficult to retain at low and mid pH. Pseudoephedrine is often analyzed by ion exchange methods. The Extend-C18 column retains these compounds in a noncharged form at high pH and improves resolution. 2 0 6 5 10 Time (min) LC80001 Long Life at High pH with Extend-C18 ZORBAX Extend-C18 773450-902 4.6 x 150 mm, 5 µm Mobile Phase: 20% Methanol 80% 0.1 M Carbonate Buffer, pH 10.0 1.0 mL/min Ambient Flow Rate: Temperature: At high pH, columns will fail due to silica dissolution. The example here shows extended lifetime of ZORBAX Extend-C18 at high pH in comparison to competitor W. This was measured by the amount of dissolved silica. 30 ZORBAX Extend-C18 Competitor W Amount of Dissolved Silica (mg) Column: 20 10 0 0 3 5 9 12 15 Volume Eluent (L) LC80002 LC AND LC/MS COLUMNS 851 Columns for Analytical HPLC Extend-C18 Provides Good Peak Shape at Low pH Column: ZORBAX Extend-C18 773450-902 4.6 x 150 mm, 5 µm Mobile Phase: 80% 25 mM NaH2PO4, pH 3.0 20% Methanol 1.0 mL/min 35°C 254 nm Basic Compounds Flow Rate: Temperature: Detector: Sample: 1 1. 2. 3. 4. 3 4 2 These basic compounds are separated on the Extend-C18 at low pH with excellent peak shape. The Extend-C18 column can be used at high and low pH. 0 1 2 3 Theobromine Dimethylxanthine Theophylline Caffeine 4 5 6 Time (min) 7 LC80003 ZORBAX 80Å Extend-C18 Hardware Description Extend-C18 Size (mm) Particle Size (µm) USP L1 Standard Columns (no special hardware required) Analytical Analytical Analytical Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Solvent Saver Solvent Saver Solvent Saver Plus Solvent Saver Plus Solvent Saver Plus 4.6 x 250 4.6 x 150 4.6 x 50 4.6 x 150 4.6 x 100 4.6 x 75 4.6 x 50 4.6 x 100 4.6 x 50 4.6 x 30 4.6 x 20 3.0 x 250 3.0 x 150 3.0 x 150 3.0 x 100 3.0 x 50 5 5 5 3.5 3.5 3.5 3.5 1.8 1.8 1.8 1.8 5 5 3.5 3.5 3.5 770450-902 773450-902 746450-902 763953-902 764953-902 766953-902 735953-902 728975-902 727975-902 724975-902 726975-902 770450-302 773450-302 763954-302 764953-302 735954-302 Unless indicated, column pressure limit is 400 bar. (Continued) 852 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC ZORBAX 80Å Extend-C18 Hardware Description Extend-C18 Size (mm) Particle Size (µm) USP L1 Standard Columns (no special hardware required) Solvent Saver RRHD, 1200 bar Solvent Saver RRHD, 1200 bar Solvent Saver HT, 600 bar Solvent Saver HT, 600 bar Solvent Saver HT, 600 bar Solvent Saver HT, 600 bar Narrow Bore Narrow Bore Narrow Bore RR Narrow Bore RR Narrow Bore RRHD, 1200 bar Narrow Bore RRHD, 1200 bar Narrow Bore RRHD, 1200 bar Narrow Bore RRHT, 600 bar Narrow Bore RRHT, 600 bar Narrow Bore RRHT, 600 bar Narrow Bore RRHT, 600 bar MicroBore RR MicroBore RR MicroBore RR MicroBore Guard, 3/pk Guard Cartridge, 4/pk Guard Cartridge, 4/pk Guard Hardware Kit 3.0 x 100 3.0 x 50 3.0 x 100 3.0 x 50 3.0 x 30 3.0 x 20 2.1 x 150 2.1 x 50 2.1 x 100 2.1 x 50 2.1 x 150 2.1 x 100 2.1 x 50 2.1 x 100 2.1 x 50 2.1 x 30 2.1 x 20 1.0 x 150 1.0 x 50 1.0 x 30 1.0 x 17 4.6 x 12.5 2.1 x 12.5 1.8 1.8 1.8 1.8 1.8 1.8 5 5 3.5 3.5 1.8 1.8 1.8 1.8 1.8 1.8 1.8 3.5 3.5 3.5 5 5 5 758700-302 757700-302 728975-302 727975-302 724975-302 726975-302 773700-902 760450-902 761753-902 735700-902 759700-902 758700-902 757700-902 728700-902 727700-902 724700-902 726700-902 763600-902 765600-902 761600-902 5185-5923 820950-930 821125-930 820999-901 PrepHT Cartridge Columns (require endfittings kit 820400-901) PrepHT Cartridge 21.2 x 150 5 770150-902 PrepHT 21.2 x 100 5 770100-902 PrepHT 21.2 x 50 5 770050-902 17 x 7.5 5 PrepHT endfittings, 2/pk PrepHT Guard Cartridge, 2/pk Guard Cartridge Hardware 820400-901 820212-930 820444-901 Unless indicated, column pressure limit is 400 bar. LC AND LC/MS COLUMNS 853 Columns for Analytical HPLC ZORBAX Rx • Recommended for alternate selectivity at low pH relative to Eclipse XDB-C18 and StableBond SB-C18; for higher temperature applications, StableBond is recommended • Higher carbon load than SB-C18 columns (12% vs. 10%). • High stability and good peak shape for low pH applications (up to pH 8) • Manufactured using dimethyloctadecylsilane and non-endcapped • Same product as SB-C8 Column Specifications Bonded Phase ZORBAX Rx-C18 ZORBAX Rx-C8 Pore Size 80Å 80Å Surface Area 180 m2/g 180 m2/g Temp. Limits 60°C 80°C pH Range* 2.0-8.0 1.0-8.0 Endcapped No No Carbon Load 12% 5.5% Specifications represent typical values only. *At pH 6-9 highest column stability for all silica based columns is obtained by operating at temperatures <40°C and using lower buffer concentrations in the range of 0.01-0.02 M. Analysis of Diazepam on Rx-C18 Column: ZORBAX Rx-C18 880967-302 3.0 x 250 mm, 5 µm Mobile Phase: Flow Rate: 35% H2O:65% MeOH 0.5 mL/min An Rx-C18 column is used for this USP analysis of diazepam and the internal standard ethylparaben. The Solvent Saver 3.0 mm ID Rx-C18 column reduces solvent usage by 60% over what would be used if the analysis was done on a 4.6 x 250 mm column. 854 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com 1 2 1. Ethylparaben 2. Diazepam 0.0 2.5 Time (min) 5.0 7.5 LCRX001 l 01357 522 961 Columns for Analytical HPLC ZORBAX Rx Hardware Description Semi-Preparative Analytical Analytical Rapid Resolution Rapid Resolution Rapid Resolution Solvent Saver Solvent Saver Solvent Saver Plus Solvent Saver Plus Narrow Bore Narrow Bore RR Guard Cartridge, 2/pk Guard Cartridge, 4/pk Guard Cartridge, 4/pk Guard Hardware Kit Guard Hardware Kit Size (mm) 9.4 x 250 4.6 x 250 4.6 x 150 4.6 x 150 4.6 x 100 4.6 x 75 3.0 x 250 3.0 x 150 3.0 x 150 3.0 x 100 2.1 x 150 2.1 x 100 9.4 x 15 4.6 x 12.5 2.1 x 12.5 9.4 x 15 Particle Size (µm) 5 5 5 3.5 3.5 3.5 5 5 3.5 3.5 5 3.5 7 5 5 Rx-C18 USP L1 880967-202 880967-902 883967-902 863967-902 861967-902 866967-902 880967-302 883967-302 863967-302 861967-302 883700-902 861767-902 820675-115 820950-914 821125-915 840140-901 820999-901 Rx-C8 USP L7* 880967-201 880967-901 883967-901 820675-115 820950-913 821125-915 840140-901 820999-901 PrepHT Cartridge Columns (require endfittings kit 820400-901) PrepHT Cartridge 21.2 x 250 7 877967-102 877250-106 PrepHT Cartridge 21.2 x 150 7 877150-106 PrepHT Cartridge 21.2 x 150 5 870150-906 PrepHT Cartridge 21.2 x 100 5 870100-906 PrepHT Cartridge 21.2 x 50 PrepHT Guard Cartridge, 2/pk 5 870050-906 5 820212-914 820212-915 Guard Cartridge Hardware 820444-901 820444-901 PrepHT endfittings, 2/pk 820400-901 820400-901 *Rx-C8 is the same product as SB-C8. For other sizes and configurations, see the ZORBAX StableBond section. Turn to pages 841–848. LC AND LC/MS COLUMNS 855 Columns for Analytical HPLC Pursuit HPLC Columns Beginning in drug discovery and drug metabolism, Pursuit columns are ideal for analyzing lead compounds and biological samples. The column's performance is due to the unique combination of advanced bonding chemistry and ultra-high purity silica. These factors combine to provide rapid separations with excellent first time resolution and symmetrical peaks for polar compounds, whether at pH 1.5 or 10. Additionally, the need for ion pairing agents such as TFA is often eliminated, thus maximizing the performance of single and parallel multi-channel LC/MS systems. Culminating in QC, Pursuit is ideal for implementing dependable trouble-free analysis of raw materials and approved drugs. Rigorous control and validation of each step in the manufacturing process ensures column reproducibility. With Pursuit your laboratory can spend its energy on producing results. Special selectivities such as Pursuit PFP (for very polar compounds) and Pursuit PAH (environmental) give you the extra selectivities you need for your most challenging applications. Pursuit For LC/MS and high throughput applications. Built on the larger 200Å pore size silica, high ligand density delivers up to 40% faster separations without sacrificing resolution. This is accomplished by optimizing mass transfer with the larger pore size. Pursuit XRs For performance in analytical R&D, QC and preparative applications. Combining high ligand density with a 100Å pore size, high surface area silica, Pursuit XRs columns are designed to increase productivity, as they offer maximum loadability, excellent stability and easy scalability while maintaining superior resolution. Tips & Tools More information is a click away. We have a variety of educational primers, application notes, maintenance guides, and literature available from Agilent for free. To learn more, visit www.agilent.com/chem/OnlineLibrary 856 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC Pursuit XRsUltra 2.8 For the ultimate in speed and good resolution on any instrument, we designed the Pursuit XRsUltra 2.8 around an optimized 2.8 µm particle and an advanced packing procedure. Now you can decrease your run time while maintaining resolution. Lower backpressure allows high flow rates to be used, and the 2.8 µm particles of ultra-pure silica delivers 10-15% higher efficiency than 3 µm columns. Pursuit UPS2.4 For maximum efficiency, particularly in high viscosity solvent separations. With an optimized 2.4 µm particle, Pursuit UPS columns offer approximately 50% lower backpressure compared to sub-2 µm columns, delivering higher speed and resolution without the need for ultra-high pressure equipment. Pursuit UPS1.9 Pursuit UPS1.9 columns deliver sub-2 µm efficiencies when sensitivity, resolution, and throughput are critical. These columns excel under the high pressures and fast gradients demanded by today's pharmaceutical industry, up to a pressure limit of 1000 bar. Column Specifications Bonded Phase Pursuit C18 Pursuit C8 Pursuit Diphenyl Pursuit PFP Pursuit PAH Pursuit XRs C18 Pursuit XRs C8 Pursuit XRs Diphenyl Pursuit XRs Si Pursuit XRsUltra 2.8 C18 Pursuit XRsUltra 2.8 C8 Pursuit XRsUltra 2.8 Diphenyl Pursuit UPS2.4 C18 Pore Size 200Å 200Å 200Å 200Å 200Å 100Å 100Å 100Å 100Å 100Å 100Å 100Å Surface Area 200 m2/g 200 m2/g 200 m2/g 200 m2/g 200 m2/g 440 m2/g 440 m2/g 440 m2/g 440 m2/g 440 m2/g 440 m2/g 440 m2/g pH Range 1.5-10 1.5-10 1.5-8.0 1.5-10 1.5-10 1.5-10 1.5-10 1.5-8.0 1.5-10 1.5-10 1.5-10 1.5-8.0 Endcapped Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 100Å 350 m2/g 1.5-10 100Å 350 m2/g 1.5-10 Pursuit UPS1.9 C18 Carbon Load 12.9% 7.4% 7.3% 6.3% 23.2% 15% 14.6% Pore Volume 1.1 mL/g 1.1 mL/g 1.1 mL/g 1.1 mL/g 1.1 mL/g 1.1 mL/g 1.1 mL/g 1.1 mL/g 1.1 mL/g 1.1 mL/g 1.1 mL/g 1.1 mL/g Yes 21% 0.9 mL/g 2.5 µmol/m2 Yes 21% 0.9 mL/g 3.0 µmol/m2 22% 15% 14.6% Ligand Coverage 3.5 µmol/m2 3.8 µmol/m2 2.8 µmol/m2 3.4 µmol/m2 2.9 µmol/m2 3.7 µmol/m2 2.6 µmol/m2 3.2 µmol/m2 3.7 µmol/m2 2.6 µmol/m2 Specifications represent typical values only. LC AND LC/MS COLUMNS 857 Columns for Analytical HPLC Tricyclic antidepressants and benzodiazepines Column: Pursuit XRs C18 A6000150X046 4.6 x 150 mm, 5 µm Mobile Phase: A: Water+0.1% HCOOH B: MeCN+0.1% HCOOH 30-40% B in 15 min, hold at 40% B for 15 min 1.0 mL/min Ambient UV, 254 nm 24 1 2 3 mAU Gradient: Flow Rate: Temperature: Detector: 1. 2. 3. 4. 5. 6. 7. 5 4 67 8 9 8. 9. 10. 11. 12. 13. 14. 7-Aminoclonazepam 7-Aminoflunitrazepam Nordoxepin Doxepin Desipramine Imipramine Nortriptyline Amitriptyline Trimipramine Clomipramine Nordiazepam Clonazepam Flunitrazepam Diazepam 10 11 14 13 12 0 min 0 24 VLC0001 Mechanical stability of Pursuit XRs Pursuit XRs C18 A6000050X020 2.0 x 50 mm, 5 µm Sample: Mobile Phase: DMSO mix A: MeOH:water, 10:90 + 0.1% HCOOH B: MeOH:water, 90:10 + 0.1% HCOOH 0-100% B in 3 min, back to 0% B in 0.5 min, hold at 0% B for 3.5 min 0.4 mL/min Ambient UV, 254 nm Gradient: Flow Rate: Temperature: Detector: 1. 4-Methoxybenzenesulfonamide 2. Methyl 3-aminothiophene-2-carboxylate 3. Trimipramine Injection 1 1 2 3 400 mAU Column: 0 0 min Injection 5000 6 1 2 3 mAU 400 0 0 858 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 min 6 VLC0002 Columns for Analytical HPLC Antifungals Pursuit XRsUltra 2.8 Diphenyl A7521050X020 2 x 50 mm, 2.8 µm Mobile Phase: Water+0.1% HCOOH:MeCN+0.1% HCOOH, 80:20 0.4 mL/min Ambient UV, 254 nm Flow Rate: Temperature: Detector: 1. 2. 3. 4. 2 240,000 1 4 3 µV Column: 4-Aminobenzoic acid Sorbic acid Benzoic acid Salicylic acid 0 0 min 6 VLC0003 Liquid chromatography phase test mixture (LPTM) on Pursuit C8 Column: Mobile Phase: Flow Rate: Detector: 2 A: 0.05% HCOOH in water B: 0.05% HCOOH in MeCN 0.6 mL/min UV, 220 nm 3 Aspartame Cortisone Reserpine Dioctyl phthalate 1 2 min 5 Adrenocorticosteroids on Pursuit PFP and C18 300 1 2 3 4 mAU Pursuit PFP 5 7 6 10 9 8 VLC0004 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. MeCN:water, 22.5:77.5 1.5 mL/min Ambient UV, 240 nm Triamcinolone Prednisolone Cortisone Methylprednisolone Corticosterone Beclomethasone Prednisolone acetate Triamcinolone acetonide Cortisone acetate Fluocinolone acetonide 0 0 Pursuit C18 300 min 1 mAU Mobile Phase: Flow Rate: Temperature: Detector: 1. 2. 3. 4. 4 Pursuit C8 A3031050X020 2.0 x 50 mm, 3 µm 2 25 3 4 10 5 6 7 8 9 0 0 min 25 VLC0005 LC AND LC/MS COLUMNS 859 Columns for Analytical HPLC Pursuit HPLC Columns Size (mm) 50 x 250 21.2 x 250 21.2 x 150 21.2 x 250 21.2 x 150 21.2 x 100 10 x 250 10 x 150 10 x 250 4.6 x 250 4.6 x 150 4.6 x 100 4.6 x 250 4.6 x 150 4.6 x 100 4.6 x 50 4.6 x 250 4.6 x 150 4.6 x 100 4.6 x 50 4.6 x 30 4.0 x 250 4.0 x 125 3.9 x 300 3.9 x 300 3.9 x 150 3.0 x 250 3.0 x 150 3.0 x 100 3.0 x 250 3.0 x 150 3.0 x 100 3.0 x 50 2.0 x 250 2.0 x 150 Particle Size (µm) 10 10 10 5 5 5 10 5 5 10 10 10 5 5 5 5 3 3 3 3 3 5 5 10 5 5 5 5 5 3 3 3 3 5 5 Pursuit C18 USP L1 A3002250X500 A3002250X212 A3002150X212 A3000250X212 A3000150X212 Pursuit C8 USP L7 Pursuit Diphenyl Pursuit PFP A3032250X500 A3032250X212 A3002250X100 A3000150X100 A3000250X100 A3002250X046 A3002150X046 A3032250X100 Pursuit PAH USP L1 A3050250X212 A3050150X212 A3040100X212 A3000250X046 A3000150X046 A3000100X046 A3000050X046 A3001250X046 A3001150X046 A3001100X046 A3001050X046 A3001030X046 A3000250X040 A3000125X040 A3002300X039 A3000300X039 A3000150X039 A3000250X030 A3000150X030 A3000100X030 A3001250X030 A3001150X030 A3001100X030 A3001050X030 A3000250X020 A3000150X020 A3050150X100 A3050250X100 A3030250X100 A3032250X046 A3032150X046 A3030250X046 A3030150X046 A3030100X046 A3030150X046 A3031250X046 A3031150X046 A3031100X046 A3040250X046 A3040150X046 A3040100X046 A3040050X046 A3041250X046 A3041150X046 A3041100X046 A3041050X046 A3040250X030 A3040150X030 A3041150X030 A3041100X030 A3041050X030 A3050250X046 A7000250X046 A3050150X046 A7000150X046 A3050100X046 A3050050X046 A3051250X046 A3051150X046 A3051100X046 A7001100X046 A3051050X046 A3050150X030 A3050100X030 A3051150X030 A3051100X030 A7001100X030 A3051050X030 A3030150X020 A3040150X020 (Continued) 860 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC Pursuit HPLC Columns Size (mm) 2.0 x 100 2.0 x 50 2.0 x 30 2.0 x 20 2.0 x 250 2.0 x 200 2.0 x 150 2.0 x 100 2.0 x 50 2.0 x 30 2.0 x 20 Particle Size (µm) 5 5 5 5 3 3 3 3 3 3 3 Pursuit C18 USP L1 A3000100X020 A3000050X020 A3000030X020 A3000020X020 A3001250X020 Pursuit C8 USP L7 Pursuit Diphenyl A3030100X020 A3040100X020 A3030050X020 A3040050X020 A3040030X020 A3001150X020 A3001100X020 A3001050X020 A3001030X020 A3001020X020 A3031150X020 A3031100X020 A3031050X020 A3031030X020 A3041250X020 A3041200X020 A3041150X020 A3041100X020 A3041050X020 A3041030X020 A3041020X020 Pursuit PAH Pursuit PFP USP L1 A3050100X020 A3050050X020 A3050030X020 A3050020X020 A3051150X020 A3051100X020 A7001100X020 A3051050X020 A3051030X020 A3051020X020 Pursuit ChromSep Complete Cartridge Systems Hardware Size (mm) 4.6 x 250 4.6 x 250 4.6 x 150 4.6 x 100 4.6 x 150 4.6 x 100 4.6 x 50 3.0 x 250 3.0 x 150 3.0 x 100 3.0 x 150 3.0 x 100 2.0 x 250 2.0 x 150 2.0 x 100 2.0 x 150 2.0 x 100 2.0 x 50 Particle Size (µm) 5 3 5 5 3 3 3 5 5 5 3 3 5 5 5 3 3 3 Pursuit C18 USP L1 A3000250C046 A3000150C046 A3000100C046 A3001150C046 A3001100C046 A3001050C046 A3000250C030 A3000150C030 A3000100C030 A3001150C030 A3001100C030 A3000250C020 A3000150C020 A3000100C020 A3001150C020 A3001100C020 A3001050C020 Pursuit C8 USP L7 A3030250C046 A3031250C046 A3030150C046 A3030100C046 A3031150C046 A3031100C046 Pursuit PAH USP L1 A7000250C046 A7000150C046 A7001150C046 A7001100C046 A7000100C030 A3030150C020 LC AND LC/MS COLUMNS 861 Columns for Analytical HPLC Pursuit ChromSep Replacement Cartridges Hardware Size (mm) 4.6 x 250 Particle Size (µm) 5 4.6 x 150 5 Unit Pursuit C18 USP L1 Pursuit C8 USP L7 3/pk 3/pk 4.6 x 150 3 4.6 x 100 3 4.6 x 50 3 3/pk A3000150R046 A3030150R046 A3000150T046 A3030150T046 A3031150R046 A3031150T046 3/pk 3/pk 3.0 x 150 5 3.0 x 100 5 3/pk 3/pk 3.0 x 150 3 3/pk 3.0 x 100 3 3/pk 2.0 x 50 A3001050R046 A3001050T046 A3000150R030 A3000150T030 A3000100R030 A3000100T030 A3001150R030 A3001150T030 A3001100R030 A3001100T030 3 Pursuit PAH USP L1 A7000250R046 A7000250T046 A7000150R046 A7000150T046 A7001150R046 A7001150T046 A7001100R046 A7001100T046 A7000100R030 A7000100T030 A7001100R030 A7001100T030 A3031050R020 A3031050T020 3/pk Pursuit XRs HPLC Columns Size Particle (mm) Size (µm) 50.0 x 250 10 30.0 x 250 5 30.0 x 150 5 30.0 x 100 5 30.0 x 50 5 21.2 x 250 10 21.2 x 250 5 21.2 x 150 5 21.2 x 100 5 21.2 x 50 5 21.2 x 30 5 Pursuit XRs C18 USP L1 A6002250X500 A6000250X300 A6000150X300 A6000100X300 A6000050X300 A6002250X212 A6000250X212 A6000150X212 A6000100X212 A6000050X212 A6000030X212 Pursuit XRs C8 USP L7 Pursuit Pursuit XRs Si XRs Diphenyl USP L3 A6002250X500 A6004250X500 A6004250X300 A6020150X300 A6012250X212 A6004250X212 A6020250X212 A6020100X212 (Continued) 862 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC Pursuit XRs HPLC Columns Size Particle (mm) Size (µm) 10.0 x 250 10 10.0 x 250 5 10.0 x 150 5 10.0 x 50 5 10.0 x 150 3 4.6 x 250 10 4.6 x 50 10 4.6 x 250 5 4.6 x 150 5 4.6 x 100 5 4.6 x 50 5 4.6 x 250 3 4.6 x 150 3 4.6 x 100 3 4.6 x 50 3 4.6 x 30 3 4.0 x 250 5 4.0 x 150 5 3.0 x 250 5 3.0 x 150 5 3.0 x 100 5 3.0 x 150 3 3.0 x 100 3 3.0 x 50 3 3.0 x 30 3 2.1 x 100 5 2.0 x 250 5 2.0 x 150 5 2.0 x 100 5 2.0 x 50 5 2.0 x 30 5 2.0 x 250 3 2.0 x 150 3 2.0 x 100 3 2.0 x 50 3 2.0 x 30 3 2.0 x 20 3 1.0 x 150 3 1.0 x 100 3 Pursuit XRs C18 USP L1 A6002250X100 A6000250X100 A6000150X100 A6000050X100 Pursuit XRs C8 USP L7 Pursuit XRs Diphenyl Pursuit XRs Si USP L3 A6004250X100 A6020250X100 A6021150X100 A6002250X046 A6002050X046S A6000250X046 A6000150X046 A6000100X046 A6000050X046 A6001250X046 A6001150X046 A6001100X046 A6001050X046 A6001030X046 A6000250X040 A6000150X040 A6000250X030 A6000150X030 A6000100X030 A6001150X030 A6001100X030 A6001050X030 A6001030X030 A6004250X046 A6010250X046 A6020250X046 A6010150X046 A6020150X046 A6010100X046 A6020100X046 A6006100X046 A6020050X046 A6006050X046 A6021250X046 A6010150X046 A6021150X046 A6011100X046 A6021100X046 A6005100X046 A6011050X046 A6021050X046 A6005050X046 A6021030X046 A6010250X040 A6010150X040 A6021150X030 A6021100X030 A6021050X030 A6006100X021 A6000250X020 A6000150X020 A6000100X020 A6000050X020 A6000030X020 A6001250X020 A6001150X020 A6001100X020 A6001050X020 A6001020X020 A6001150X010 A6001100X010 A6020250X020 A6010150X020 A6020150X020 A6010100X020 A6010050X020 A6020050X020 A6021250X020 A6011150X020 A6021150X020 A6011100X020 A6021100X020 A6011050X020 A6021050X020 A6005050X020 A6021030X020 A6021100X010 LC AND LC/MS COLUMNS 863 Columns for Analytical HPLC Pursuit XRsUltra 2.8 HPLC Columns Size (mm) 3.0 x 150 3.0 x 100 2.0 x 150 2.0 x 100 2.0 x 50 2.0 x 30 Particle Size (µm) 2.8 2.8 2.8 2.8 2.8 2.8 Pursuit XRsUltra 2.8 C18 A7501150X030 A7501100X030 A7501150X020 A7501100X020 A7501050X020 A7501030X020 Pursuit XRsUltra 2.8 C8 A7511150X030 Pursuit XRsUltra 2.8 Diphenyl A7511100X020 A7511050X020 A7511030X020 A7521100X020 A7521050X020 A7521030X020 Pursuit UPS2.4 HPLC Columns Size (mm) 3.0 x 100 3.0 x 50 2.0 x 100 2.0 x 50 2.0 x 30 Particle Size (µm) 2.4 2.4 2.4 2.4 2.4 Pursuit UPS2.4 A8100100X030H A8100050X030H A8100100X020H A8100050X020H A8100030X020H Pursuit UPS1.9 HPLC Columns Size (mm) 3.0 x 100 3.0 x 50 2.0 x 100 2.0 x 50 2.0 x 30 Particle Size (µm) 1.9 1.9 1.9 1.9 1.9 Pursuit UPS1.9 C18 A8000100X030H A8000050X030H A8000100X020H A8000050X020H A8000030X020H Tips & Tools Agilent offers a variety of e-Seminars and on-site training to help you learn how to be a more effective chromatographer. For more information, visit www.agilent.com/chem/education 864 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Pursuit UPS1.9 Diphenyl A8020100X030H A8020050X030H A8020100X020H A8020050X020H A8020030X020H Columns for Analytical HPLC Polaris HPLC Columns In areas like drug discovery where target compounds are increasingly polar, it is critical to have a reverse phase column that performs well under aqueous conditions. Retention is critical, but cannot come with troublesome secondary interactions. Likewise, phase collapse and shifting retention times need to be avoided. The answer is our Polaris line of polar-modified columns. From the collapse-resistant pore structure of our base silica, to the "wettability" engineered into the bonded phases, Polaris columns have been designed for high aqueous conditions. The combination of high phase density bonding, ultra pure silica, and silanol shielding leads to excellent peak shape among polar-modified columns. As a family, Polaris offers a variety of polar modifications in both C18 and C8 chemistries. Polaris C18-A Polaris C18-A is the best starting place for separations where the benefits of polar-modified columns are desired. The polar modifications of C18-A help it avoid poor peak shape and retention issues in low organic conditions. Polaris C8-A Polaris C8-A offers an alternative selectivity to standard C8 phases and has a lower hydrophobicity than Polaris C18-A, making it ideal for polar samples, or faster overall analysis times. Polaris C18-Ether Polaris C18-Ether offers an alternative selectivity to Polaris C18-A and standard C18 phases, and typically delivers increased retention of polar compounds away from the void volume. Polaris C8-Ether Polaris C8-Ether offers an alternative selectivity to Polaris C8-A with particular utility for hydrogen bonding compounds. LC AND LC/MS COLUMNS 865 Columns for Analytical HPLC Column Specifications Bonded Phase Pore Size Polaris C18-A 180Å Polaris C8-A 180Å Polaris C18-Ether 180Å Polaris C8-Ether 180Å Surface Carbon Area Load 200 m2/g 13.8% 200 m2/g 7.4% 200 m2/g 12.1% 200 m2/g 7.1% Pore Volume 1.1 cm3/g 1.1 cm3/g 1.1 cm3/g 1.1 cm3/g Endcapped Yes Yes Yes Yes Ligand Coverage 3.9 µmol/m2 4.8 µmol/m2 3.3 µmol/m2 4.5 µmol/m2 Specifications represent typical values only. Selectivity text mix for Polaris columns MeCN:water 70:30 1.0 mL/min Ambient UV, 254 nm Polaris C8-A 1. 2. 3. 4. 5+8 6 400 mAU Mobile Phase: Flow Rate: Temperature: Detector: 12 3 4 7 Uracil Caffeine Phenol Toluene 5. 6. 7. 8. Butylbenzene o-Terphenyl Amylbenzene Triphenylene 0 0 min 14 Polaris C18-A 400 7 5 mAU 1 8 6 4 2 3 0 0 min 14 VLC0007 LC/MS performance test mix for Polaris C8-A Polaris C8-A A2011030X030 3.0 x 30 mm, 3 µm Mobile Phase: A: Water+0.05% HCOOH B: MeCN+0.05% HCOOH 5-90% B in 3 min and hold for 4 min 0.6 mL/min Ambient UV, 220 nm Gradient: Flow Rate: Temperature: Detector: 866 LC AND LC/MS 1. 2. 3. 4. 3 4 2 400 Aspartame Cortisone Reserpine Dioctyl phthalate 1 mAU Column: 0 0 www.agilent.com/chem/lccolumns www.crawfordscientific.com min l 01357 522 961 8 VLC0008 Columns for Analytical HPLC Polaris HPLC Columns Size (mm) 50 x 250 30 x 100 21.2 x 250 21.2 x 250 21.2 x 150 21.2 x 100 21.2 x 50 10 x 250 10 x 50 4.6 x 250 4.6 x 250 4.6 x 200 4.6 x 150 4.6 x 100 4.6 x 50 4.6 x 30 4.6 x 250 4.6 x 150 4.6 x 100 4.6 x 75 4.6 x 50 4.6 x 30 4.0 x 250 4.0 x 150 4.0 x 125 3.0 x 250 3.0 x 150 3.0 x 100 3.0 x 50 3.0 x 250 3.0 x 200 3.0 x 150 3.0 x 100 3.0 x 50 3.0 x 30 Particle Size (µm) 10 5 10 5 5 5 5 5 3 10 5 5 5 5 5 5 3 3 3 3 3 3 5 5 5 5 5 5 5 3 3 3 3 3 3 Polaris C18-A A2002250X500 A2000100X300 A2002250X212 A2000250X212 A2000150X212 A2000100X212 Polaris C8-A Polaris C18-Ether Polaris C8-Ether Polaris NH2 A2010250X212 A2020250X212 A2030250X212 A2013250X212 Polaris Si-A A2004250X500 A2004250X212 A2003250X212 A2003150X046 A2003050X212 A2000250X100 A2002250X046 A2000250X046 A2000200X046 A2000150X046 A2000100X046 A2000050X046 A2000030X046 A2001250X046 A2001150X046 A2001100X046 A2001075X046 A2001050X046 A2001030X046 A2000250X040 A2000150X040 A2000250X030 A2000150X030 A2000100X030 A2000050X030 A2001250X030 A2001200X030 A2001150X030 A2001100X030 A2001050X030 A2001030X030 A2020250X100 A2021050X100 A2030250X100 A2013250X100 A2010250X046 A2020250X046 A2030250X046 A2013250X046 A2010150X046 A2010100X046 A2020150X046 A2030150X046 A2013150X046 A2013100X046 A2013050X046 A2003150X046 A2003100X046 A2003050X046 A2021250X046 A2031250X046 A2014250X046 A2014150X046 A2014100X046 A2005250X046 A2005150X046 A2005100X046 A2021050X046 A2031050X046 A2014050X046 A2005050X046 A2013250X040 A2013150X040 A2013125X040 A2013250X030 A2013150X030 A2013100X030 A2014250X030 A2003250X040 A2003150X040 A2003125X040 A2005250X046 A2003150X030 A2003100X030 A2003050X030 A2003250X030 A2014150X030 A2014100X030 A2014050X030 A2005150X030 A2005100X030 A2005050X030 A2003250X046 A2020050X046 A2011150X046 A2011100X046 A2011075X046 A2020150X030 A2021150X030 A2021050X030 A2031050X030 A2011030X030 (Continued) LC AND LC/MS COLUMNS 867 Columns for Analytical HPLC Polaris HPLC Columns Size (mm) 2.0 x 250 2.0 x 150 2.0 x 100 2.0 x 50 2.0 x 30 2.0 x 20 2.0 x 250 2.0 x 150 2.0 x 100 2.0 x 75 2.0 x 50 2.0 x 30 2.0 x 20 Particle Size (µm) 5 5 5 5 5 5 3 3 3 3 3 3 3 Polaris C18-A A2000250X020 A2000150X020 A2000100X020 A2000050X020 A2000030X020 A2000020X020 A2001250X020 A2001150X020 A2001100X020 Polaris C8-A A2010150X020 Polaris C18-Ether A2020250X020 A2020150X020 Polaris C8-Ether A2030250X020 A2030150X020 A2010050X020 A2020050X020 A2030050X020 A2011250X020 A2011150X020 A2021250X020 A2021150X020 A2021100X020 A2021075X020 A2021050X020 A2021050X020 A2031250X020 A2031150X020 A2031100X020 A2001050X020 A2001030X020 A2001020X020 A2011050X020 A2031050X020 Tips & Tools To learn more about Agilent's complete portfolio of services, please visit www.agilent.com/chem/services 868 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Polaris NH2 A2013250X020 A2013150X020 A2013100X020 A2013050X020 A2013030X020 A2013020X020 A2014250X020 A2014150X020 A2014100X020 Polaris Si-A A2003250X020 A2003150X020 A2003100X020 A2003050X020 A2003030X020 A2003020X020 A2005250X020 A2005150X020 A2005100X020 A2014050X020 A2014030X020 A2014020X020 A2005050X020 A2005030X020 A2005020X020 Columns for Analytical HPLC Polaris ChromSep Complete Cartridge Systems Hardware Size (mm) 4.6 x 250 4.6 x 150 4.6 x 100 4.6 x 250 4.6 x 150 3.0 x 250 3.0 x 100 2.0 x 100 2.0 x 150 2.0 x 100 2.0 x 50 Particle Size (µm) 5 5 5 3 3 5 5 5 3 3 3 Polaris C18-A A2000250C046 A2000150C046 A2000100C046 A2001250C046 A2001150C046 A2000250C030 A2000100C030 A2000100C020 A2001150C020 A2001100C020 A2001050C020 Polaris ChromSep Replacement Cartridges Hardware Size (mm) 4.6 x 250 Particle Size (µm) 5 Unit 3/pk 4.6 x 150 5 3/pk 4.6 x 100 5 4.6 x 150 3 4.6 x 100 3 3/pk 3/pk 3/pk 3.0 x 150 5 3.0 x 100 5 3.0 x 100 3 2.0 x 150 3 2.0 x 50 3 3/pk 3/pk 3/pk 3/pk 3/pk Polaris C18-A A2000250R046 A2000250T046 A2000150R046 A2000150T046 A2000100R046 A2000100T046 A2001150R046 A2001150T046 A2001100R046 A2001100T046 A2000150R030 A2000150T030 A2000100R030 A2000100T030 A2001100R030 A2001100T030 A2001150R020 A2001150T020 A2001050R020 A2001050T020 LC AND LC/MS COLUMNS 869 Columns for Analytical HPLC ZORBAX Original Reversed-Phase Columns Agilent Original ZORBAX columns are made with Type A silica and are useful for many applications of acidic or neutral compounds. These columns have a higher activity level and are therefore useful for separating isomers (e.g. cis-trans, geometric) or other compounds where silanol activity enhances selectivity. These columns are used in many established methods. ZORBAX Original Reversed Phase Columns Hardware Description Size (mm) Particle ODS (C18) Size (µm) USP L1 C8 USP L7 Phenyl USP L11 CN USP L10 TMS USP L13 Standard Columns (no special hardware required) Semi-Preparative Analytical (Endcapped) Analytical (Non-endcapped) Analytical Solvent Saver Solvent Saver 9.4 x 250 4.6 x 250 4.6 x 250 4.6 x 150 3.0 x 250 3.0 x 150 5 5 5 5 5 5 880952-202 880952-206 880952-702 880952-706 880952-712 884950-507 880952-710 884950-543 883952-702 883952-706 883952-712 884950-526 883952-710 880952-302 883952-302 9.4 x 15 4.6 x 12.5 7 5 820675-115 820950-902 840140-901 820999-901 7 877952-102 877952-106 877952-105 820400-901 820400-901 820400-901 Guard Columns (hardware required) Guard Cartridge, 2/pk Guard Cartridge, 4/pk Guard Hardware Kit Guard Hardware Kit 820675-115 820950-906 840140-901 820999-901 820675-115 820950-912 840140-901 820999-901 820675-124 820950-905 820950-924 840140-901 840140-901 820999-901 820999-901 PrepHT Cartridge Columns (require endfittings kit 820400-901) PrepHT Cartridge 21.2 x 250 PrepHT endfittings, 2/pk 870 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC Agilent TC-C18(2) and HC-C18(2) TC-C18(2) Agilent TC-C18(2) is the ideal choice for complex natural product extract samples, traditional medicines and environmental samples or any sample where you need to analyze mixtures of polar and non-polar compounds, including strong basic compounds. • Lower carbon load – 12% • Ideal for polar compounds and gradient separations that start at low % organic or cover a wide organic range • Good choice for samples dissolved in water, or mostly water • Use with most common mobile phases, including formic acid, acetic acid, trifluoroacetic acid (TFA) and phosphate buffers with acetonitrile and methanol as the organic modifiers • Excellent performance from pH 2-8 HC-C18(2) Agilent HC-C18(2) is a more retentive C18 with a higher carbon load. An excellent value alternative to other high carbon load columns, it also provides superior peak shape for basic compounds. • Higher carbon load – 17% – provides greater retention for moderately polar and non-polar compounds • Ideal for non-polar compounds and separations that start at mid-level % organic (at least greater than 10% organic) • Good choice for industrial samples or samples dissolved in organic/mostly organic solvents • Stable over a very wide pH range (2-9) for maximum flexibility LC AND LC/MS COLUMNS 871 Columns for Analytical HPLC Column Specifications Bonded Phase TC-C18 (2) HC-C18 (2) Pore Size 170Å 170Å Temp. Surface Area Limits 60°C 290 m2/g 60°C 290 m2/g Carbon pH Range* Endcapped Load 2.0-8.0 Yes 12% 2.0-9.0 Yes 17% Specifications represent typical values only. Agilent HC-C18(2) and TC-C18(2) Description Agilent HC-C18(2) Agilent HC-C18(2) Agilent TC-C18(2) Agilent TC-C18(2) Agilent HC-C18(2) guards, 2/pk Agilent TC-C18(2) guards, 2/pk Guard Hardware Kit Size (mm) 4.6 x 250 4.6 x 150 4.6 x 250 4.6 x 150 4.6 x 12.5 4.6 x 12.5 Particle Size (µm) 5 5 5 5 5 5 Tips & Tools Don't forget, we have special offers throughout the year. To learn more, visit www.agilent.com/chem/specialoffers 872 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Part No. 588905-902 588915-902 588925-902 588935-902 520518-904 520518-905 820999-901 Columns for Analytical HPLC Normal-Phase Columns ZORBAX Normal-Phase Columns For normal-phase chromatography, the Agilent ZORBAX product line offers a choice of bonded and non-bonded silica packings. ZORBAX Rx-SIL • Made from highly pure (>99.995%) porous silica microspheres (pore size is the space between the solid silica microparticles) • Available in 1.8 and 5 µm particle sizes • Stronger than other silica types • Less acidic than ZORBAX-SIL, lower metal content • Low acidity and low metal content make ZORBAX Rx-SIL ideal for normal-phase separation of polar compounds that exhibit poor peak symmetry on more acidic silica • Useful for very hydrophilic compounds with high organic mobile phases in HILIC mode ZORBAX Eclipse XDB-CN • Made from highly pure Rx-SIL • Excellent choice for normal-phase applications with basic compounds • Equilibrates more rapidly than ZORBAX Rx-SIL and is used for many of the same normalphase applications LC AND LC/MS COLUMNS 873 Columns for Analytical HPLC Pursuit XRs Silica is another choice for normal-phase chromatography. For more information, see page 862–863. ZORBAX CN • Cyanopropyldimethylsilane monolayer bonded to ZORBAX SIL • Equilibrates more rapidly than ZORBAX SIL, and used for many of the same normal-phase applications • Less prone to fouling and less water sensitive than silica ZORBAX NH2 • Amino-propyl silane phase bonded to ZORBAX SIL • Used for normal-phase and weak anion-exchange, and reversed-phase HPLC of polar compounds • Vitamins A and D are separated in the normal-phase mode • Carbohydrates and sugars are separated in the reversed-phase mode Column Specifications Bonded Phase ZORBAX Rx-SIL ZORBAX Eclipse XDB-CN ZORBAX SIL ZORBAX CN ZORBAX NH2 Pore Size 80Å 80Å Surface Area 180 m2/g 180 m2/g pH Range 0-8.0 2.0-8.0 Endcapped No Yes 70Å 70Å 70Å 300 m2/g 300 m2/g 300 m2/g 0-8.0 2.0-7.0 2.0-7.0 No Yes Yes Carbon Load 7% 4% High Resolution Normal-Phase Separation of Octylphenoxy Ethanol Surfactant on ZORBAX CN Column: ZORBAX CN 880952-705 4.6 x 250 mm, 5 µm Mobile Phase: Primary: Heptane Secondary: 2-Methoxyethanol/Isopropanol (50/50) 2 mL/min 2-20% Secondary in 10 min., Linear Hold at 20% 50°C 278 nm Octylphenoxy (polyethylene oxy) Ethanol Surfactant (n= 10) Flow Rate: Gradient: Temperature: Detector: Sample: 0 874 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com 5 10 l 01357 522 961 15 Time (min) 4.3% 20 LCNP001 Columns for Analytical HPLC Normal-Phase Columns Based on ZORBAX Rx-SIL Hardware Description Size (mm) Particle Size (µm) Rx-SIL USP L3 Eclipse XDB-CN USP L10 Standard Columns (no special hardware required) Semi-Prep Analytical Analytical Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar Narrow Bore Rapid Resolution HT, 600 bar Rapid Resolution HT, 600 bar 9.4 x 250 4.6 x 250 4.6 x 150 4.6 x 100 4.6 x 50 3.0 x 100 3.0 x 50 2.1 x 150 2.1 x 100 2.1 x 50 5 5 5 1.8 1.8 1.8 1.8 5 1.8 1.8 880975-201 880975-901 883975-901 828975-901 827975-901 828975-301 827975-301 883700-901 828700-901 827700-901 9.4 x 15 4.6 x 12.5 2.1 x 12.5 9.4 x 15 5 5 5 0 820675-119 820950-919 821125-919 840140-901 820999-901 990967-905* 993967-905* 993700-905* Guard Columns (hardware required) Guard Cartridge, 2/pk Guard Cartridges, 4/pk Guard Cartridge, 4/pk Guard Hardware Kit Guard Hardware Kit 820950-935 821125-935 820999-901 PrepHT Cartridge Columns (require endfittings kit 820400-901) PrepHT Cartridge 21.2 x 250 7 PrepHT Cartridge 21.2 x 250 7 PrepHT endfittings, 2/pk PrepHT Guard Cartridge, 2/pk Guard Cartridge Hardware 877250-101 820400-901 17 x 7.5 5 820212-919 820444-901 *These columns ship containing reversed-phase solvents. Flush with isopropanol before using normal-phase solvents. These columns can also be used in HILIC mode. LC AND LC/MS COLUMNS 875 Columns for Analytical HPLC Normal-Phase Columns Based on ZORBAX Original SIL Hardware Description Size (mm) Particle Size (µm) SIL USP L3 CN USP L10 NH2 USP L8 Carbohydrate Analysis 840300-908 843300-908 Standard Columns (no special hardware required) Semi-Prep Analytical Analytical Narrow Bore 9.4 x 250 4.6 x 250 4.6 x 150 2.1 x 50 5 5 5 5 880952-201 880952-701 883952-701 880952-205 880952-705 883952-705 880952-208 880952-708 883952-708 860700-708 9.4 x 15 4.6 x 12.5 2.1 x 12.5 9.4 x 15 5 5 5 820675-119 820950-901 820675-111 820950-905 820675-111 820950-908 820950-908 840140-901 820999-901 840140-901 820999-901 840140-901 820999-901 820888-901 877952-105 877952-108 820400-901 820400-901 Guard Columns (hardware required) Guard Cartridge, 2/pk Guard Cartridges, 4/pk Guard Cartridge, 4/pk Guard Hardware Kit Guard Hardware Kit PrepHT Cartridge Columns (require endfittings kit 820400-901) PrepHT Cartridge 21.2 x 250 7 PrepHT Cartridge 21.2 x 250 7 17 x 7.5 5 PrepHT endfittings, 2/pk PrepHT Guard Cartridge, 2/pk 877952-101 820400-901 Guard Cartridge Hardware 876 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC ZORBAX HILIC Plus • HILIC column for good retention of small, polar analytes • Based on Eclipse Plus silica for excellent peak shape • High sensitivity for LC/MS applications • Recommended for EPA Method 1694 Agilent ZORBAX HILIC Plus columns are for use in hydrophilic interaction chromatography (HILIC) applications, which are typically used for the retention and resolution of small polar compounds. HILIC Plus columns are non-bonded silica columns based on the high performance silica used in ZORBAX Eclipse Plus columns. This silica provides excellent peak shape, critical for many polar, basic analytes. These columns ship prepared for use in HILIC mode – containing acetonitrile:water – in order to reduce the extensive equilibration typically required for HILIC separations. HILIC Plus columns are available in a 3.5 µm particle size for high resolution and in 2.1 and 4.6 mm ID for compatibility with mass spectrometers or with standard UV detectors. Column Specifications Bonded Phase Non-bonded silica Pore Size Surface Area pH Range 95Å 160 m2/g 0-8.0 Specifications represent typical values only. Tips & Tools More information is a click away. We have a variety of educational primers, application notes, maintenance guides, and literature available from Agilent for free. To learn more, visit www.agilent.com/chem/OnlineLibrary LC AND LC/MS COLUMNS 877 Columns for Analytical HPLC Separation of Group 4 Analytes in EPA 1694 on ZORBAX HILIC Plus Column Column: ZORBAX HILIC Plus 959793-901 2.1 x 100 mm, 3.5 µm Mobile Phase: Flow Rate: Gradient: 90% Acetontrile:10% Water 0.25 mL/min Linear gradient to 55% acetonitrile in 7 min Held at 55% 25°C Temperature: Metformin Cimetidine x102 1.00 0.95 0.90 0.85 0.80 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 Albuterol Ranitidine x102 Duplicate runs for column USCJP0004; 10 min equilibration between two runs 1.00 0.95 0.90 0.85 0.80 0.75 0.70 0.65 0.60 0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5 13.0 13.5 14.0 14.5 15.0 15.5 16.0 16.5 17.0 17.5 18.0 18.5 19.0 19.5 20.0 20.5 21.0 21.5 22.0 22.5 23.0 23.5 24.0 24.5 EPA1694 ZORBAX HILIC Plus Description Analytical Analytical Narrow Bore Narrow Bore 878 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com Size (mm) 4.6 x 100 4.6 x 50 2.1 x 100 2.1 x 50 l 01357 522 961 Particle Size (µm) 3.5 3.5 3.5 3.5 Part No. 959961-901 959943-901 959793-901 959743-901 Columns for Analytical HPLC Ion Exchange Columns ZORBAX Ion Exchange Columns – SAX and SCX • ZORBAX SAX and 300SCX columns are based on rugged ZORBAX silica • Stable from pH 2-7 • Provide high efficiency, rapid separations • Compatible with organic mobile phase modifiers Agilent ZORBAX Strong Ion Exchange columns are available as both Strong Anion Exchange (SAX) and Strong Cation Exchange (300SCX) columns. Each column is packed with bonded, 5 µm, spherical silica particles for optimum efficiency. ZORBAX SAX packing has a permanently bonded quaternary amine. A trifunctional organo-silane reagent is used in producing this packing to maximize its stability with aqueous mobile phases. This column is ideal for separation of water-soluble compounds such as aromatic and aliphatic carboxylic acids and sulfonic acids. ZORBAX SCX packing has 300Å pore size silica particles chemically bonded to an aromatic sulfonic acid group. This column is used for separations of basic, water-soluble compounds and bio-molecules. Column Specifications Bonded Phase ZORBAX SAX Pore Size 70Å Surface Area 300 m2/g pH Range 2.0-7.0 ZORBAX 300SCX 300Å 50 m2/g 2.0-7.0 Functionality Quaternary amine Sulfonic acid Max Pressure 350 bar 350 bar Specifications represent typical values only. LC AND LC/MS COLUMNS 879 Columns for Analytical HPLC Cough/Cold Remedies on ZORBAX 300SCX Column: ZORBAX 300SCX 880952-704 4.6 x 250 mm, 5 µm Mobile Phase: Flow Rate: Temperature: Detector: Sample: 100 mM NaH2PO4 (pH 6.5) 3 mL/min 20°C 210 nm Cold remedies 1 1. 2. 3. 4. 5. 2 3 0 4 5 2 4 Time (min) Pyrilamine Theophylline Glyceryl Guaicolate Caffeine Phenylephrine LCIE001 ZORBAX Ion Exchange Columns – SAX and SCX Description Semi-preparative Analytical Analytical Analytical Solvent Saver Narrow Bore Narrow Bore Guard Cartridge, 4/pk Guard Hardware Kit 880 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com Size (mm) 9.4 x 250 4.6 x 250 4.6 x 150 4.6 x 50 3.0 x 50 2.1 x 150 2.1 x 50 4.6 x 12.5 Particle Size (µm) 5 5 5 5 5 5 5 6 l 01357 522 961 SAX 880952-203 880952-703 883952-703 820950-903 820888-901 300SCX 880952-204 880952-704 883952-704 846952-704 860700-304 883700-704 860700-704 820950-904 820888-901 Columns for Analytical HPLC Hi-Plex HPLC Columns • Preferred separation mechanism for the analysis of carbohydrates and oligosaccharides • Matched to the USP definitions of media types L17, L19, L34 and L58 • Ideal for isocratic separations using water or dilute acid as the eluent Hi-Plex columns are ion exchange or ligand exchange columns used predominantly for the separation of carbohydrates and organic acids. These columns are the preferred separation mechanism for the analysis of simple sugars, alcohols, oligosaccharides and organic acids in foodstuffs, but they can be used for the separation of other compounds as well. The range comprises a 4% cross-linked resin for the analysis of oligosaccharides and an 8% cross-linked resin, with lower exclusion limit, for mono-, di- and tri-saccharide analysis. For carbohydrate and alcohol investigations, Hi-Plex columns use isocratic conditions with water as the eluent and temperature as the main variable for control of resolution. The exception is the Hi-Plex Na (Octo), which is used with sodium hydroxide eluents when pulsed amperometric detection (PAD) is employed. Column Specifications Bonded Phase Hi-Plex Ca Hi-Plex Ca USP L19 Hi-Plex Pb Hi-Plex H for carbohydrates Hi-Plex H for organic acids Hi-Plex Ca (Duo) Hi-Plex K Hi-Plex Na (Octo) Hi-Plex Na Temperature Range 80-90°C 80-90°C 70-90°C 60-70°C 40-60°C 80-90°C 80-90°C 80-90°C Flow Rate (mL/min) 0.6 0.3 0.6 0.6 0.6 0.6 0.6 0.6 80-90°C 0.3 Eluent Water Water Water Water Dilute Acid Water Water Water, Sodium Hydroxide Water LC AND LC/MS COLUMNS 881 Columns for Analytical HPLC Hi-Plex Column Selection USP methods specify the type of HPLC media and column dimensions which should be used for the analysis. The Hi-Plex product range has four materials that comply with USP definitions. Media Type L17 Strong cation exchange resin consisting of sulfonated, cross-linked styrene-divinylbenzene copolymer in the hydrogen form, 7 to 11 µm in diameter – Hi-Plex H. Media Type L19 Strong cation exchange resin consisting of sulfonated, cross-linked styrene-divinylbenzene copolymer in the calcium form, 9 µm in diameter – Hi-Plex Ca and Hi-Plex Ca (Duo). Media Type L34 Strong cation exchange resin consisting of sulfonated, cross-linked styrene-divinylbenzene copolymer in the lead form, about 9 µm in diameter – Hi-Plex Pb. Media Type L58 Strong cation exchange resin consisting of sulfonated, cross-linked styrene-divinylbenzene copolymer in the sodium form, 6 to 30 µm diameter – Hi-Plex Na and Hi-Plex Na (Octo). In addition to the standard column sizes, the media is also packed in specific column dimensions for different USP methods, including sugar alcohol analysis. For some application areas there are several column options, and the choice of the most appropriate Hi-Plex media will depend on sample matrix and exact carbohydrate composition. 882 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Columns for Analytical HPLC Hi-Plex Column Selection Application Area USP Methods Specifying L17 Media USP Methods Specifying L19 Media USP Methods Specifying L34 Media USP Methods Specifying L58 Media Mono- and Disaccharides Anomer Separations Organic Acids Alcohols Adulteration of Food and Beverages Food Additives Dairy Products Sweetened Dairy Products Confectionery Fruit Juice Wine Wood Pulp Hydrolysates (cellulose/hemi-cellulose) Fermentation Monitoring Oligosaccharides Samples with High Salt Content (molasses) Oligosaccharides 90% purity. Separations up to 2000 mg are possible depending on the complexity of separation. 0 1 2 3 4 Time (min) 5 6 7 MSD Vial 2 – 343 Vial 1 – 347 8000000 Vial 3 – 389 1. Nifedipine 2. Nimodine 3. Nisoldipine 6000000 4000000 2000000 0 1 2 3 4 Time (min) 5 6 7 LCPHT01 Amount Nifedipin [mg] Amount Nifmodipin [mg] Amount Nifsoldipin [mg] Fraction 1 Fraction 2 Fraction 3 Recovery [mg] Recovery [%] 918 LC AND LC/MS 18.90 0.29 0.49 19.68 101.3 0.11 17.66 1.66 19.43 102.0 www.agilent.com/chem/lccolumns www.crawfordscientific.com 0.16 0.77 18.36 19.29 101.9 l 01357 522 961 Purity Nifedipin Purity Nifmodipin Purity Nifsoldipin 98.6% 94.4% 89.5% Preparative HPLC Columns and Flash Chromatography ZORBAX PrepHT columns are designed for rapid scale-up from analytical to preparative scale without losing resolution. For complex separations for larger columns (21.2 mm ID and higher, 150 mm length and higher), Agilent has carefully chosen the 7 µm particle size to achieve a balance between high efficiency and high loadability. Scale-Up from Analytical to Prep ZORBAX SB-C18 Columns Using the Same Pump Flow (mL/min) 100 18 3.5 0.85 Column Size Column 1 50 x 150 mm Column 2 21.2 x 150 mm Column 3 9.4 x 150 mm Column 4 4.6 x 150 mm Injection (µL) 2200 400 80 2.0 Detector Cell 0.3 mm quartz 0.3 mm quartz 0.3 mm quartz 3 mm SST Part No. Custom Column 877150-102 883975-202 883975-902 Using the same 1100 pump, a scale-up from 4.6 mm to 50 mm ID was possible without any loss of resolution. This increases throughput by reducing the time required for redeveloping and adjusting the method. Scale-Up to PrepHT 2 3500 3 Abundance (mAU) 3000 1. Theobromine 2. Theophylline 3. Caffeine 2500 2000 Column 1 1500 1 Column 2 1000 Column 3 500 Column 4 0 0 2.5 5.0 7.5 10.0 12.5 Time (min) 15.0 17.5 20.0 LCPHT_ScaleUp LC AND LC/MS COLUMNS 919 Preparative HPLC Columns and Flash Chromatography ZORBAX PrepHT 80ÅStableBond (require hardware 820400-901) Particle Size SB-C18 SB-C8 SB-CN SB-Phenyl (µm) USP L1 USP L7 SB-Aq USP L10 USP L11 7 877250-102 877250-106 877250-114 877250-105 877250-112 Hardware Description PrepHT Cartridge Size (mm) 21.2 x 250 PrepHT Cartridge 21.2 x 150 7 877150-102 877150-106 877150-114 PrepHT Cartridge 21.2 x 150 5 870150-902 870150-906 870150-914 PrepHT Cartridge 21.2 x 100 5 870100-902 870100-906 870100-914 PrepHT Cartridge 21.2 x 50 5 870050-902 870050-906 870050-914 PrepHT Guard Cartridge, 2/pk 17 x 7.5 5 820212-920 820212-915 820212-933 820212-933 820212-915 ZORBAX PrepHT 300ÅStableBond (require hardware 820400-901) Particle Size 300SB-C18 (µm) USP L1 7 897250-102 300SB-C8 USP L7 897250-106 300SB-C3 USP L56 897250-109 897150-102 897150-106 897150-109 895150-902 895150-906 895150-909 5 895100-902 895100-906 895100-909 5 895050-902 895050-906 895050-909 Hardware Description PrepHT Cartridge Size (mm) 21.2 x 250 PrepHT Cartridge 21.2 x 150 7 PrepHT Cartridge 21.2 x 150 5 PrepHT Cartridge 21.2 x 100 PrepHT Cartridge 21.2 x 50 PrepHT Guard Cartridge, 2/pk 17 x 7.5 5 Guard Cartridge Hardware Includes guard column end fitting, polymeric seal, and seal insertion tool (seal holder and seal pusher) PrepHT endfittings, 2/pk 300SB-CN USP L10 897250-105 820212-921 820212-918 820212-924 820212-924 820444-901 820444-901 820444-901 820444-901 820400-901 820400-901 820400-901 820400-901 ZORBAX PrepHT Original (require hardware 820400-901) Hardware Description PrepHT Cartridge Size (mm) 21.2 x 250 Particle Size ODS (C18) C8 CN NH2 SIL (µm) USP L1 USP L7 USP L10 USP L8 USP L3 7 877952-102 877952-106 877952-105 877952-108 877952-101 PrepHT endfittings, 2/pk 920 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com 820400-901 820400-901 820400-901 820400-901 820400-901 l 01357 522 961 Preparative HPLC Columns and Flash Chromatography ZORBAX PrepHT Eclipse XDB (require hardware 820400-901) Eclipse XDB-C18 USP L1 977250-102 Eclipse XDB-C8 USP L7 977250-106 Hardware Description PrepHT Cartridge Size (mm) 21.2 x 250 Particle Size (µm) 7 PrepHT Cartridge 21.2 x 150 7 977150-102 977150-106 PrepHT Cartridge 21.2 x 150 5 970150-902 970150-906 PrepHT Cartridge 21.2 x 100 5 970100-902 970100-906 PrepHT Cartridge 21.2 x 50 5 970050-902 970050-906 PrepHT Guard Cartridge, 2/pk 17 x 7.5 5 Guard Cartridge Hardware Includes guard column end fitting, polymeric seal, and seal insertion tool (seal holder and seal pusher) PrepHT endfittings, 2/pk 820212-925 820212-926 820444-901 820444-901 820400-901 820400-901 Extend-C18 USP L1 ZORBAX PrepHT Bonus-RP and Extend-C18 (require hardware 820400-901) Hardware Description PrepHT Cartridge Size (mm) 21.2 x 250 Particle Size (µm) 7 Bonus-RP USP L60 878250-101 PrepHT Cartridge 21.2 x 150 7 878150-101 PrepHT Cartridge 21.2 x 150 5 868150-901 770150-902 PrepHT Cartridge 21.2 x 100 5 868100-901 770100-902 PrepHT Cartridge 21.2 x 50 5 868050-901 770050-902 PrepHT Guard Cartridge, 2/pk 17 x 7.5 5 820212-928 820212-930 Guard Cartridge Hardware 820444-901 Includes guard column end fitting, polymeric seal, and seal insertion tool (seal holder and seal pusher) PrepHT endfittings, 2/pk 820400-901 820444-901 820400-901 ZORBAX PrepHT Rx-SIL (require hardware 820400-901) Hardware Description PrepHT Cartridge Size (mm) 21.2 x 250 Particle Size (µm) 7 PrepHT Cartridge 21.2 x 250 7 PrepHT Guard Cartridge, 2/pk 17 x 7.5 5 Guard Cartridge Hardware Includes guard column end fitting, polymeric seal, and seal insertion tool (seal holder and seal pusher) PrepHT endfittings, 2/pk Rx-SIL USP L3 877250-101 Rx-C18 USP L1 877967-102 820212-919 820212-914 820444-901 820444-901 820400-901 820400-901 ZORBAX PrepHT Accessories Hardware Description Guard Cartridge Hardware Part No. 820444-901 PrepHT endfittings, 2/pk 820400-901 Replacement Seals 820385-901 LC AND LC/MS COLUMNS 921 Preparative HPLC Columns and Flash Chromatography Agilent Prep LC Columns • High loadability for maximum sample purification • Easy scalability from 4.6 up to 50 mm ID for rapid method development • High throughput 21.2 mm ID cartridges for fast purification • Exceptional column stability and loadability up to pH 10 Agilent Prep LC columns are designed for high loadability to purify milligram to gram quantities of products. Preparative sized columns are available in 21.2, 30, and 50 mm internal diameters with lengths ranging from 50-250 mm. Columns are available in 5 and 10 µm particle sizes with very high efficiency in every dimension. These column choices accommodate almost every preparative sample. Agilent Prep 21.2 mm ID columns are available with Agilent’s Preparative Cartridge Hardware. This reliable cartridge hardware makes it simple to use columns with different lengths to increase sample load. Guard columns are easily integrated onto these columns, providing superior protection of the analysis column. Analytical size 4.6 mm ID scalar columns are available for method development and optimization prior to scaling up to larger columns. Bulk material is also available. Agilent Prep columns are available in a C18 bonded phase suitable for purification of a wide variety of non-polar and polar compounds. Unbonded silica columns are also available. Column Specifications Bonded Phase C18 Silica Pore Size 100Å 100Å Surface Area 400 m2/g 400 m2/g Temp. Limits pH Range 60°C* 2.0-10.0 ** 1.0-8.0 Specifications represent typical values only. *Temperature limits are 60°C up to pH 8, 40°C from pH 8-10. **Temperature limits for bare silica are determined by the pH of the mobile phase. 922 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Endcapped Carbon Load Single 24% N/A N/A Preparative HPLC Columns and Flash Chromatography Superior Loadability on Agilent Prep C18 with Basic Compounds Column: Mobile Phase: Flow Rate: Sample: Agilent Prep C18 443905-902 4.6 x 150 mm, 5 µm 50% 0.1%TFA:50% ACN 1 mL/min 10 µL Doxepin/Amitriptyline 0.5-50 mg/mL Agilent Prep C18 Competitor W-C18 mAU mAU 4000 40 35 30 25 20 15 10 5 0 α = 1.6 3500 3000 2500 2000 1500 1000 500 0 Agilent Prep columns show better resolution and loadability than competitor columns. 0 1 2 3 4 5 6 Time (min) 7 8 α = 1.57 0 9 1 2 3 4 5 6 Time (min) 7 8 9 LCPLC01 Steroids: Easy Scalability Using Agilent Prep Columns Column A: Column B: Column C: Column D: Mobile Phase: Flow Rate: Temperature: Detector: Sample: Agilent Prep C18 443905-902 4.6 x 150 mm, 5 µm 443905-102 21.2 x 150 mm, 5 µm 413910-302 30.0 x 150 mm, 10 µm 413910-502 50.0 x 150 mm, 10 µm 55% Water:45% ACN 0.7 mL/min 14.87 mL/min 29.77 mL/min 85.37 mL/min Ambient 240 nm 2 µL 42.4 µL 170 µL 488 µL 1. Hydrocortisone 2. Testosterone (in MeOH @ 1mg/mL) A 0 1 2 B 4 2 6 8 10 12 1 2 0 2 C 4 6 8 10 12 1 2 0 2 D 4 6 8 10 12 1 Agilent Prep C18 shows excellent scalability, making method transfer simple and predictable. 2 0 2 4 6 Time (min) 8 10 12 LCPLC02 LC AND LC/MS COLUMNS 923 Preparative HPLC Columns and Flash Chromatography Agilent Prep LC Columns Hardware Description Size (mm) Particle Size (µm) C18 Silica Standard Columns (no special hardware required) Scalar Scalar Scalar Scalar Scalar Scalar Scalar 4.6 x 250 4.6 x 150 4.6 x 100 4.6 x 250 4.6 x 150 4.6 x 100 4.6 x 50 10 10 10 5 5 5 5 440910-902 443910-902 449910-902 440905-902 443905-902 449905-902 446905-902 440910-901 443910-901 440905-901 443905-901 449905-901 446905-901 PrepHT Cartridge Columns (require endfittings kit 820400-901)* PrepHT 21.2 x 250 10 410910-102 410910-101 PrepHT 21.2 x 150 10 413910-102 413910-101 PrepHT 21.2 x 50 10 446910-102 PrepHT 21.2 x 150 5 443905-102 443905-101 PrepHT 21.2 x 100 5 449905-102 449905-101 PrepHT 21.2 x 50 5 446905-102 446905-101 PrepHT endfittings, 2/pk 820400-901 820400-901 Standard Columns (no special hardware required) Prep 30 Prep 30 Prep 30 Prep 30 Prep 30 Prep 50 Prep 50 Prep 50 Prep 50 30.0 x 250 30.0 x 150 30.0 x 100 30.0 x 100 30.0 x 50 50.0 x 250 50.0 x 150 50.0 x 100 50.0 x 100 10 10 10 5 5 10 10 10 5 410910-302 413910-302 419910-302 449905-302 446905-302 410910-502 413910-502 419910-502 449905-502 410910-301 413910-301 419910-301 449905-301 446905-301 410910-501 413910-501 419910-501 449905-501 10 420212-902 420212-901 Guard Columns (hardware required) PrepHT Guard 21.2 x 10 Cartridges, 2/pk Guard Cartridge Hardware 820444-901 820444-901 PrepHT External Guard Hardware Kit Bulk Packing (1kg) 420420-901 420420-901 10 420910-902 420910-901 *All PrepHT cartridge columns require hardware kit P/N 820400-901. If a guard column is desired for the 21.2 mm ID columns, the PrepHT Guard Hardware Kit, P/N 820444-901, is also required. If the guard column is used on a 30 mm ID column then the external guard column hardware kit, P/N 420420-901, is required. 924 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Preparative HPLC Columns and Flash Chromatography High Efficiency Purification for Small Molecule Separations • Small column sizes for high-speed media selection, method development and purification • Comprehensive range of selectivities • Packed columns and bulk media Agilent offers a range of high efficiency, small particle silica and polymeric HPLC materials. These are pre-packed preparative columns and bulk media for reverse phase, normal phase and ion exchange purification. A range of pore sizes is available, providing maximum capacity for all applications, from small molecules to biological macromolecules. Small Molecule Separations Separation Hydrophobic Media Characterization Highest Mass Loading Hydrophobic Work Horse Hydrophilic Aromatic/Double Bonds Polar Selectivity H-bond Accepting Reverse or Normal-Phase H-bonding Normal-Phase Organic Soluble Extreme Conditions pH Extremes/High Temperatures Column Pursuit XRs 100Å C18 Pursuit XRs 100Å C8 Pursuit 200Å C18 Pursuit 200Å C8 Pursuit 200Å Diphenyl Polaris 200Å C18-A Polaris 200Å C8-A Polaris 200Å C18-Ether Polaris 200Å C8-Ether Polaris 200Å NH2 Polaris 200Å Amide-C8 Pursuit XRs Si Pursuit XRs Diol PLRP-S 100Å, 8 µm LC AND LC/MS COLUMNS 925 Preparative HPLC Columns and Flash Chromatography Pursuit High Efficiency XRs Columns for Small Molecule Separations Size (mm) 21.2 x 250 21.2 x 250 21.2 x 100 10.0 x 250 10.0 x 250 Particle Size (µm) 10 5 5 10 5 XRs C18 A6002250X212 A6000250X212 XRs C8 XRs Diphenyl XRs Diol A6020250X212 A3040250X212 XRs Si A6004250X100 A6010100X212 A6002250X100 A6000250X100 A6020250X100 High Efficiency Bulk Media 100 g 10 A6002100G A6012100G A6004100G Pursuit High Efficiency Columns for Small Molecule Separations Size (mm) 21.2 x 250 21.2 x 250 10.0 x 250 10.0 x 250 Particle Size (µm) 10 5 10 5 C18 A6002250X212 A3000250X212 A6002250X100 A3000250X100 C8 A3032250X212 A3030250X212 A3032250X100 A3030250X100 Diphenyl A3042250X212 A3040250X212 A3042250X100 A3040250X100 PFP A3050250X212 A3050250X100 Polaris High Efficiency Columns for Small Molecule Separations Size (mm) 21.2 x 250 21.2 x 250 10.0 x 250 10.0 x 250 926 Particle Size (µm) 10 5 10 5 C18-A C18-Ether Amide C18 C8-A C8-Ether NH2 Si-A A2002250X212 A2008250X212 A2004250X212 A2000250X212 A2030250X212 A2006250X212 A2010250X212 A2030250X212 A2013250X212 A2003250X212 A2008250X100 A2000250X100 A2020250X100 A2006250X100 A2010250X100 A2030250X100 A2013250X100 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Preparative HPLC Columns and Flash Chromatography Dynamax Preparative HPLC Columns • Modular design with reusable end fittings reduces hardware costs • Three internal diameters – 10, 21.4 and 41.4 mm – for easy scale-up • Integral guard column option for longer column lifetimes with complex samples The Dynamax preparative column hardware utilizes a patented dynamic axial compression (DAC) design and is the ideal format for the development and optimization of a high throughput or high yield purification. The DAC principle of operation maintains packed bed integrity and improves column performance over an extended period of time with a reduction in operating costs. Agilent offers Dynamax columns as compression modules (cartridges) onto which separate axial compression end fittings are fitted. This provides a means of eliminating voids that may form at the column inlet during use and also enables the end fittings to be reused. When changing the column it is only necessary to replace the compression module with one of a similar internal diameter. There are three options when configuring a Dynamax column. To simplify choice, end fittings kits are available for each of the configurations. Kit #1 contains the end fittings for using the Dynamax column without a guard module. Kit #2 contains all the parts needed to operate with a protective guard module. There is also a guard coupling assembly parts kit to upgrade Kit #1 to Kit #2. When the guard column is used as a short preparative column only the standalone guard holder is needed. SepTech ST60 10-C18 and SepTech ST150 10-C18 media designed for high performance separations at high capacity are available in the Dynamax format for rapid method development and small-scale separations. Dynamax Column Hardware Kits Description End fittings kit #1 End fittings kit #2 Guard coupling assembly Upgrades kit #1 to kit #2 Standalone guard holder ID (mm) 10 21.4 41.4 10 21.4 41.4 10 21.4 41.4 10 21.4 41.4 Part No. R000083810 R000083820 R000083840 R000083812 R000083822 R000083842 R000083811 R000083821 R000083841 R000083814 R000083824 R000083844 LC AND LC/MS COLUMNS 927 Preparative HPLC Columns and Flash Chromatography SepTech C18 Reverse Phase Media • Symmetrical peaks improve yield of high purity product • High capacity delivers maximum throughput • Narrow particle size distribution improves packed bed stability SepTech media has been developed specifically for prep to process HPLC, from the definition of the base silica particle, pore sizes, pore volume, specific surface area, mechanical strength and particle size distribution through to the bonding chemistry, ligand density and end capping. The result is two products: SepTech ST60 10-C18 – optimized for small molecule purifications, and SepTech ST150 10-C18 – the preferred option for larger, natural molecules and biomolecules. The high level of batch-to-batch reproducibility and particle integrity give consistent performance and ease of column packing, which are essential for minimizing production downtime. SepTech media helps you meet the demands of a robust and economical process by purifying the maximum amount of product at the required purity in the shortest period of time. Column Specifications Characteristics Nominal Particle Size Nominal Pore Size Nominal Distribution Shape Silica Purity Chemistry End Capping Carbon Load Ligand Coverage Working pH Range 928 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com SepTech ST60 10-C18 10 µm 60Å <2 d90/d10 Spherical 99.999% Octadecyl Yes 25% 3.5 µmol/m2 1.5-10 l 01357 522 961 SepTech ST150 10-C18 10 µm 150Å <2 d90/d10 Spherical 99.999% Octadecyl Yes 15% 3.8 µmol/m2 1.5-10 Preparative HPLC Columns and Flash Chromatography SepTech ST60 10-C18 Description Method Development Column Dynamax Packed Cartridge Module Bulk media Size (mm) 4.6 x 250 10 x 50 10 x 250 21.2 x 50 21.2 x 250 41.4 x 50 41.4 x 250 100 g 1 kg Part No. A8060250X046 A8060050DG100 A8060250DM100 A8060050DG214 A8060250DM214 A8060050DG414 A8060250DM414 A80600100G A8060001KG Size (mm) 4.6 x 250 10 x 50 10 x 250 21.2 x 50 21.2 x 250 41.4 x 50 41.4 x 250 100 g 1 kg Part No. A8150250X046 A8150050DG100 A8150250DM100 A8150050DG214 A8150250DM214 A8150050DG414 A8150250DM414 A81500100G A8150001KG SepTech ST150 10-C18 Description Method Development Column Dynamax Packed Cartridge Module Bulk media Tips & Tools Don't forget, we have special offers throughout the year. To learn more, visit www.agilent.com/chem/specialoffers LC AND LC/MS COLUMNS 929 Preparative HPLC Columns and Flash Chromatography FlowTrap • Reduced dry-down times improve productivity • Desalting in situ preserves compound integrity • Retentive sorbent handles a wide range of sample pH and pKa FlowTrap columns contain ultra-retentive, high capacity, and hydrophobic polymeric material that captures and concentrates small molecules. Once trapped, the desired analyte can be back eluted using a small volume of volatile organic solvent, affording simple compound isolation. FlowTrap columns give you excellent retention and easy elution. The efficiency of the packed bed delivers superior reproducibility and can be used for up to 500 flow-trapping cycles when run under optimized conditions. With FlowTrap you can solvent switch from a high volume of water-based HPLC eluent to a low volume of volatile solvent, dramatically reducing the evaporation times needed for compound isolation. Ion pairing reagents such as TFA can be removed from the compound during trapping, allowing the isolation of free-base compounds and reducing the risk of potential compound hydrolysis. FlowTrap is available in standard HPLC column hardware covering a range of column sizes that handle seamless scale-up as compound batch sizes increase. Using FlowTrap columns will help you dramatically reduce dry-down times, increasing throughput for compound recovery. Tips & Tools More information is a click away. We have a variety of educational primers, application notes, maintenance guides, and literature available from Agilent for free. To learn more, visit www.agilent.com/chem/OnlineLibrary 930 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Preparative HPLC Columns and Flash Chromatography FlowTrap Size (mm) 4.6 x 150 7.5 x 150 10.0 x 150 21.2 x 150 Capacity Range (mg)* 50 50-150 150-200 200-400 Part No. PL1560-3M07 PL1160-3M07 PL1060-3M07 PL1E60-3M07 *Recommendation only, based on representative loading studies. Capacity will vary according to compound type and eluent constitution. Metronidazole TFA removal Column: FlowTrap PL1560-3M07 4.6 x 150 mm, µm Mobile Phase: Metronidazole (12 mL) @ 2 mg/mL in water + 0.1% TFA Caffeine @ 2 mg/mL in water + 0.1% TFA Detector: UV, 280 nm Wash Conditions: Method A: R.O. water flow rate: 4 mL/min for 4 min Method B: 2 M NH3, flow rate: (4 mL/min) for 2 min then R.O. water, flow rate: (4 mL/min) for 4 min Elution: 100% CH3CN over 5 min flow rate: (4 mL/min) Method A Method B 0 min 35 VLC0013 LC AND LC/MS COLUMNS 931 Preparative HPLC Columns and Flash Chromatography Load & Lock Preparative HPLC Systems Agilent offers a complete range of Load & Lock column systems for laboratory and process preparative LC. They are designed to enable you to easily and quickly pack your own preparative high efficiency columns. This is the right solution for applications ranging in scale from discovery (milligrams) to production (multi-kilos) of pharmaceutical compounds, peptides, and natural products. Our Load & Lock columns have a unique fluid/sample distribution system to maximize productivity. It is the only system that provides dynamic axial compression (DAC) and static "locked" axial compression (SAC) and is designed for easy operation to deliver greater convenience. Laboratory Load & Lock Columns • Mobile packing station supports three different column sizes • Runs on compressed air with no need for a power supply • Quick and easy packing and unpacking within minutes Agilent's laboratory scale Load & Lock columns combine excellent packed-bed stability with enhanced flow distribution to deliver the highest quality purification possible with maximum speed, flexibility and ease of operation. Three different column sizes are supported: 1 in., 2 in. and 3 in. ID. Because the station is powered by compressed air, it is the perfect solution for hazardous environments. The quick-release single bolt clamp offers speedy and easy packing and unpacking within minutes. Load & Lock Preparative HPLC Systems Description Load & Lock 4001 Column Load & Lock 4002 Column Load & Lock 4003 Column Water Jacket No Yes Spare parts kit No Yes Spare parts kit No Yes Spare parts kit Mobile packing station (air driven hydraulic) 932 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Size (mm) 25 x 500 25 x 500 50 x 500 50 x 500 75 x 500 75 x 500 Part No. PCG93LL500X25 PCG93LL500X25WJ PCG931AAKIT PCG93LL500X50 PCG93LL500X50WJ PCG932AAKIT PCG93LL500X75 PCG93LL500X75WJ PCG933AAKIT PCG93LLSTAND123 Preparative HPLC Columns and Flash Chromatography Flash Chromatography • Isolate compounds from synthesis mixtures quickly and easily • Maximize compound purity and recovery with superior purification columns • Enhance gradient accuracy with solid loading system Flash chromatography purifies reaction products to isolate the target compound. Flash columns are designed for purification. Every element has been thought out, custom designed and carefully manufactured for excellent purification performance, time after time. SuperFlash Purification Columns • Sixteen standard sizes plus customized sizes for a wide application range • Short, wide columns for speed and long, thin columns for resolution • Flat packaging for stock room organization and supply visibility to maintain inventory Each element of the SuperFlash compound purification column, with our patented and patentpending technologies, delivers optimal performance, offering maximum recovery of high purity compounds time after time. Our columns, available in Si 50, Si 35, C18, PLRP-S and SCX for normal and reverse phase separations, and a variety of other sorbents, eliminate the common problems of leaking, size limitations, complicated connections and poor compound separation. Instead, you receive a cost-effective, high performance disposable column specifically designed for delivering convenient, efficient separations. LC AND LC/MS COLUMNS 933 Preparative HPLC Columns and Flash Chromatography Media selection Normal phase (NP) Low or medium polarity Acidic Acidic alumina (NP) Reverse phase (RP) Reverse phase (RP) High polarity Acid sensitive Neutral alumina (NP) Sample Low or medium polarity Neutral High polarity Normal phase (NP) Neutral alumina (NP) Reverse phase (RP) Normal phase (NP) Low or medium polarity Amine (NP/RP) Basic alumina (NP) Basic Reverse phase (RP) High polarity Strong Cation Exchange (SCX) Standard Female Luer Lock Easily connects to any system or to a DASi injection cartridge. Unitized Construction Patent pending unitized construction hermetically seals the column into a single unit to eliminate leaking up to 200 psi. Identification Stripe Solvent proof (laser etched/no ink) red stripe includes data on column specifications and helpful information for reordering. Normal-phase columns have a red stripe, while reversed-phase columns have a blue stripe. Solvent Resistant Column Body The column body and cap design use a material that does not swell, warp or crack under prolonged solvent contact. Dispersion Channels Load sample evenly onto the column. Standard Male Luer Lock Male luer outlet attaches to any system. 934 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Preparative HPLC Columns and Flash Chromatography Solvent Polarity Polarity Index at 20°C Non-polar Polar 0.0 0.0 0.0 0.2 1.0 1.6 2.8 3.1 3.9 4.0 4.0 4.1 5.1 5.1 5.2 5.8 9.0 Solvent Heptane Hexane Pentane Cyclohexane Trichloroethylene Carbon tetrachloride di-Ethyl ether Dichloromethane Propan-2-ol Propan-1-ol Tetrahydrofuran Chloroform Acetone Methanol Ethanol Acetonitrile Water LC AND LC/MS COLUMNS 935 Preparative HPLC Columns and Flash Chromatography SuperFlash Notes This information applies to the following SuperFlash ordering tables. • Maximum pressure for all columns is 14 bar (200 psi). • Obey pressure maximum limits marked on every column. Confirm the instrument has been set to the appropriate maximum pressure before attaching column. • Dimensions are for sorbent bed diameter x overall column length. • Flow rates up to 40% higher than the recommended normal operating flow rates may be used to reduce equilibration times. • Sample loading values are suggested. Results may vary with specific samples. Normal Phase (NP) SuperFlash Si 50 Model SF10 - 4 g SF10 - 8 g SF15 - 12 g SF15 - 24 g SF25 - 40 g SF25 - 60 g SF25 - 80 g SF25 - 120 g SF25 - 160 g SF40 - 80 g SF40 - 120 g SF40 - 150 g SF40 - 240 g SF65 - 200 g SF65 - 400 g SF65 - 600 g 936 LC AND LC/MS Diameter x Length (mm) 14.2 x 95 14.2 x 136 20.8 x 112 20.8 x 175 28.2 x 164 28.2 x 214 28.2 x 280 28.2 x 388 28.2 x 507 40.6 x 158 40.6 x 202 40.6 x 257 40.6 x 371 66 x 156 66 x 256 66 x 365 Particle Size (µm) 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 www.agilent.com/chem/lccolumns www.crawfordscientific.com Flow Rate (mL/min) 18 18 30 30 40 40 40 40 40 85 85 85 85 100 100 100 l 01357 522 961 Sample Load 40 - 400 mg 80 - 800 mg 120 mg - 1.2 g 240 mg - 2.4 g 400 mg - 4 g 600 mg - 6 g 800 mg - 8 g 1.2 - 12 g 1.6 - 16 g 800 mg - 8 g 1.2 - 11.5 g 1.5 - 15 g 2.4 - 24 g 2 - 20 g 4 - 40 g 6 - 60 g Unit 8/pk 8/pk 7/pk 7/pk 6/pk 6/pk 6/pk 6/pk 6/pk 4/pk 4/pk 4/pk 4/pk 3/pk 3/pk 3/pk Part No. AX1368-8 AX1403-8 AX1369-7 AX1404-7 AX1281-6 AX1212-6 AX1213-6 AX1214-6 AX1215-6 AX1356-4 AX1216-4 AX1217-4 AX1218-4 AX1357-3 AX1219-3 AX1220-3 Preparative HPLC Columns and Flash Chromatography SuperFlash Si 35 Model SF10 - 4 g SF10 - 8 g SF15 - 12 g SF15 - 24 g SF25 - 40 g SF25 - 60 g SF25 - 80 g SF25 - 120 g SF25 -160 g SF40 - 80 g SF40 - 115 g SF40 - 150 g SF40 - 240 g SF65 - 200 g SF65 - 400 g SF65 - 600 g Diameter x Length (mm) 14.2 x 95 14.2 x 136 20.8 x 112 20.8 x 175 28.2 x 164 28.2 x 215 28.2 x 280 28.2 x 388 40.6 x 507 40.6 x 158 40.6 x 202 40.6 x 257 40.6 x 371 66 x 156 66 x 256 66 x 365 Particle Size (µm) 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 Flow Rate (mL/min) 18 18 30 30 40 40 40 40 40 85 85 85 85 100 100 100 Sample Load 40 - 400 mg 80 - 800 mg 120 mg - 1.2 g 240 mg - 2.4 g 400 mg - 4 g 600 mg - 6 g 800 mg - 8 g 1.2 - 12 g 1.6 - 16 g 800 mg - 8 g 1.2 - 11.5 g 1.5 - 15 g 2.4 - 24 g 2 - 20 g 4 - 40 g 6 - 60 g Unit 8/pk 8/pk 7/pk 7/pk 6/pk 6/pk 6/pk 6/pk 6/pk 4/pk 4/pk 4/pk 4/pk 3/pk 3/pk 3/pk Part No. AX1370-8 AX1407-8 AX1371-7 AX1408-7 AX1393-6 AX1292-6 AX1293-6 AX1294-6 AX1295-6 AX1405-4 AX1296-4 AX1297-4 AX1298-4 AX1406-3 AX1299-3 AX1300-3 SuperFlash Aminopropyl – NH2 Model SF10 - 5 g SF10 - 10 g SF15 - 15 g SF15 - 30 g SF25 - 50 g SF25 - 75 g SF25 - 100 g SF25 - 150 g SF25 -200 g SF40 - 100 g SF40 - 150 g SF40 - 200 g SF40 - 300 g SF65 - 250 g SF65 - 500 g SF65 - 750 g Diameter x Length (mm) 14.2 x 96 14.2 x 136 20.8 x 113 20.8 x 174 28.2 x 163 28.2 x 220 28.2 x 277 28.2 x 391 28.2 x 506 40.6 x 159 40.6 x 207 40.6 x 255 40.6 x 379 66 x 157 66 x 262 66 x 365 Particle Size (µm) 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 Flow Rate (mL/min) 18 18 30 30 40 40 40 40 40 85 85 85 85 100 100 100 Unit 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk Part No. AX1374-1 AX1511-1 AX1375-1 AX1512-1 AX1311-1 AX1376-1 AX1377-1 AX1378-1 AX1379-1 AX1380-1 AX1316-1 AX1317-1 AX1381-1 AX1382-1 AX1319-1 AX1383-1 LC AND LC/MS COLUMNS 937 Preparative HPLC Columns and Flash Chromatography Strong Cation Exchange (SCX) SuperFlash SCX Model SF10 - 5 g SF10 - 8 g SF15 - 14 g SF15 - 25 g SF25 - 45 g SF25 - 70 g SF25 - 80 g SF25 - 120 g SF25 - 160 g SF40 - 80 g SF40 - 125 g SF40 - 160 g SF40 - 245 g SF65 - 250 g SF65 - 440 g SF65 - 650 g 938 LC AND LC/MS Diameter x Length (mm) 14.2 x 49 14.2 x 81 20.8 x 63 20.8 x 114 28.2 x 114 28.2 x 186 28.2 x 206 28.2 x 308 28.2 x 414 40.6 x 99 40.6 x 153 40.6 x 208 40.6 x 299 66 x 118 66 x 204 66 x 302 Particle Size (µm) 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 www.agilent.com/chem/lccolumns www.crawfordscientific.com Flow Rate (mL/min) 18 18 30 30 40 40 40 40 40 85 85 85 85 100 100 100 l 01357 522 961 Unit 8/pk 8/pk 7/pk 7/pk 6/pk 6/pk 6/pk 6/pk 6/pk 4/pk 4/pk 4/pk 4/pk 3/pk 3/pk 3/pk Part No. AX2130-8 AX2135-8 AX2140-7 AX2145-7 AX2150-6 AX2155-6 AX2160-6 AX2165-6 AX2170-6 AX2175-4 AX2180-4 AX2185-4 AX2190-4 AX2195-3 AX2200-3 AX2205-3 Preparative HPLC Columns and Flash Chromatography Reversed Phase (RP) SuperFlash PLRP-S Model SF10 - 2.5 g SF10 - 4 g SF15 - 7 g SF15 - 13 g SF25 - 24 g SF25 - 38 g SF25 - 42 g SF25 - 63 g SF25 - 85 g SF40 - 42 g SF40 - 65 g SF40 - 90 g SF40 - 130 g SF65 - 133 g SF65 - 230 g SF65 - 340 g Diameter x Length (mm) 14.2 x 95 14.2 x 127 20.8 x 112 20.8 x 163 28.2 x 163 28.2 x 235 28.2 x 255 28.2 x 357 28.2 x 463 40.6 x 148 40.6 x 202 40.6 x 257 40.6 x 348 66 x 170 66 x 256 66 x 354 Particle Size (µm) 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 Flow Rate (mL/min) 12 12 20 20 30 30 30 30 30 50 50 50 50 65 65 65 Sample Load 15 - 60 mg 25 - 100 mg 41 - 167 mg 75 - 300 mg 138 - 500 mg 188 - 750 mg 250 mg - 1 g 375 mg - 1.5 g 500 mg - 2 g 250 mg - 1 g 375 mg - 1.5 g 500 mg - 2 g 750 mg - 3 g 750 mg - 3 g 1.4 - 5.4 g 2-8g Unit 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk Part No. AX2250-1 AX2255-1 AX2260-1 AX2265-1 AX2270-1 AX2275-1 AX2280-1 AX2285-1 AX2290-1 AX2295-1 AX2300-1 AX2305-1 AX2310-1 AX2315-1 AX2320-1 AX2325-1 Diameter x Length (mm) 14.2 x 95 14.2 x 127 20.8 x 112 20.8 x 163 28.2 x 163 28.2 x 235 28.2 x 255 28.2 x 357 28.2 x 463 40.6 x 148 40.6 x 202 40.6 x 257 40.6 x 348 66 x 172 66 x 256 66 x 354 Particle Size (µm) 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 Flow Rate (mL/min) 12 12 20 20 30 30 30 30 30 50 50 50 50 65 65 65 Sample Load 15 - 60 mg 25 - 100 mg 41 - 167 mg 75 - 300 mg 138 - 500 mg 188 - 750 mg 250 mg - 1 g 375 mg - 1.5 g 500 mg - 2 g 250 mg - 1 g 375 mg - 1.5 g 500 mg - 2 g 750 mg - 3 g 750 mg - 3 g 1.4 - 5.4 g 2-8g Unit 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk 1/pk Part No. AX1372-1 AX1409-1 AX1373-1 AX1410-1 AX1394-1 AX1302-1 AX1303-1 AX1304-1 AX1305-1 AX1411-1 AX1306-1 AX1307-1 AX1308-1 AX1412-1 AX1309-1 AX1310-1 SuperFlash C18 Model SF10 - 5 g SF10 - 10 g SF15 - 16 g SF15 - 30 g SF25 - 55 g SF25 - 75 g SF25 - 100 g SF25 - 150 g SF25 - 200 g SF40 - 100 g SF40 - 150 g SF40 - 205 g SF40 - 300 g SF65 - 300 g SF65 - 540 g SF65 - 800 g LC AND LC/MS COLUMNS 939 Preparative HPLC Columns and Flash Chromatography Normal Phase (NP) Alumina SuperFlash Alumina Model SF10 - 8 g SF10 - 16 g SF15 - 24 g SF15 - 48 g SF25 - 80 g SF25 - 120 g SF25 - 160 g SF25 - 240 g SF25 - 320 g SF40 - 160 g SF40 - 230 g SF40 - 300 g SF40 - 480 g SF65 - 400 g SF65 - 800 g SF65 - 1200 g Diameter x Particle Size Length (mm) (µm) 14.2 x 95 125 14.2 x 136 125 20.8 x 112 125 20.8 x 175 125 28.2 x 163 125 28.2 x 215 125 28.2 x 280 125 28.2 x 388 125 28.2 x 507 125 40.6 x 158 125 40.6 x 214 125 40.6 x 256 125 40.6 x 388 125 66 x 157 125 66 x 262 125 66 x 365 125 Sample Load 80 - 400 mg 150 - 750 mg 230 mg - 1.2 g 450 mg - 2.2 g 750 mg - 2.2 g 1.1 - 5.5 g 1.5 - 7.5 g 2.2 - 11 g 3 - 15 g 1.5 - 7.5 g 2.2 - 11 g 2.8 - 10 g 4.5 - 22.5 g 3.7 - 18.5 g 7.5 - 37.5 g 11.2 - 56 g Unit 8/pk 8/pk 7/pk 7/pk 6/pk 6/pk 6/pk 6/pk 6/pk 4/pk 4/pk 4/pk 4/pk 3/pk 3/pk 3/pk Alumina Neutral AX1448-8 AX1477-8 AX1466-7 AX1468-7 AX1449-6 AX1481-6 AX1483-6 AX1462-6 AX1485-6 AX1487-4 AX1489-4 AX1438-4 AX1473-4 AX1463-3 AX1491-3 AX1493-3 Alumina Acidic AX1474-8 AX1494-8 AX1495-7 AX1496-7 AX1497-6 AX1498-6 AX1499-6 AX1500-6 AX1501-6 AX1502-4 AX1503-4 AX1504-4 AX1505-4 AX1506-3 AX1507-3 AX1508-3 Tips & Tools Agilent offers a variety of e-Seminars and on-site training to help you learn how to be a more effective chromatographer. For more information, visit www.agilent.com/chem/education 940 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Alumina Basic AX1450-8 AX1476-8 AX1467-7 AX1469-7 AX1478-6 AX1480-6 AX1482-6 AX1464-6 AX1484-6 AX1486-4 AX1488-4 AX1437-4 AX1479-4 AX1465-3 AX1490-3 AX1492-3 Preparative HPLC Columns and Flash Chromatography Flash F75/F150 Cartridges • Available in a variety of sizes for development systems • Convenient sorbents to meet your needs • Consistent packing for less channelling and fraction dilution If you regularly purify more than a few grams of compound, Flash F75/F150 cartridges deliver the convenience and compatibility you need. The cartridges are packed with silica for normal phase separations and silica C18 for reverse phase purifications. For development scale they are available in different bed diameters and bed masses to provide solutions for a range of sample sizes. Flash F75 Cartridges Model F75S - 200 g F75S - 200 g F75S - 200 g F75S - 200 g F75S - 300 g F75M - 400 g F75M - 400 g F75M - 400 g F75M - 400 g F75M - 600 g F75L - 800 g F75L - 800 g F75L - 800 g F75L - 800 g F75L - 1.2 kg F75XL - 1.6 kg Sorbent Si 50 Si 50 Si 35 Si 35 C18 Si 50 Si 35 Si 35 Si 35 C18 Si 50 Si 50 Si 35 Si 35 C18 Si 50 Unit 2/pk 10/pk 2/pk 10/pk 1/pk 2/pk 10/pk 2/pk 10/pk 1/pk 2/pk 10/pk 2/pk 10/pk 1/pk 2/pk Part No. AX0346-2 AX0346-10 AX1363-2 AX1363-10 AX0349-1 AX0347-2 AX0347-10 AX1364-2 AX1364-10 AX0350-1 AX0348-2 AX0348-10 AX1352-2 AX1352-10 AX0351-1 AX1178-2 Unit 2/pk 10/pk 2/pk 10/pk 1/pk 2/pk 10/pk 2/pk 10/pk 1/pk Part No. AX0355-2 AX0355-10 AX1360-2 AX1360-10 AX0357-1 AX0356-2 AX0356-10 AX1361-2 AX1361-10 AX0414-1 Flash F150 Cartridges Model F150M - 2.5 kg F150M - 2.5 kg F150M - 2.5 kg F150M - 2.5 kg F150M - 3.9 kg F150L - 5 kg F150L - 5 kg F150L - 5 kg F150L - 5 kg F150L - 9 kg Sorbent Si 50 Si 50 Si 35 Si 35 C18 Si 50 Si 50 Si 35 Si 35 C18 LC AND LC/MS COLUMNS 941 Preparative HPLC Columns and Flash Chromatography DASi Sample Loading Module • For even loading of low solubility and high viscosity compounds • Modules are available in three sizes to match your sample needs • Adjustable plunger eliminates dead volume and maintains gradient accuracy • Provides security as a guard column for high-cost, specialty-sorbent columns DASi Module Kits Description DASi 12 module kit Includes five empty cartridges and two Si 50, 5 g packed cartridges DASi 35 module kit Includes five empty cartridges, two Si 50, 5 g packed cartridges and two Si 50, 10 g packed cartridges DASi 65 module kit Includes five empty cartridges, two Si 50, 5 g packed cartridges, two Si 50, 15 g packed cartridges and two Si 50, 25 g packed cartridges DASi 12, 35 and 65 module kit Part No. AX1238-1 AX1237-1 AX1236-1 AX1239-1 Each module kit contains plunger assembly and appropriate DASi Si Cartridge Sampler Kit DASi Si Cartridge Sampler Pack Description DASi 12 cartridge sampler pack DASi 35 cartridge sampler pack DASi 65 cartridge sampler pack DASi Module (showing one pre-packed cartridge) Standard Female Luer Lock Easily connect the DASi to any system with a female Luer lock top fitting. Patent Pending Locking Mechanism Easily push piston down. Assembly will remain in position until released. Adjustable Plunger Head Eliminates dead volume to maintain the superior gradient accuracy of the 971-FP instrument (especially important for DCM/methanol solvent combination). Sample Cartridge Solvent compatible cartridge body does not swell, warp, or crack under prolonged solvent contact. Dispersion Channels Distribute solvent evenly on the sample bed for tight, thin separation bands. Standard Male Luer Lock Male Luer outlet attaches to any system or to the top of a SuperFlash column. 942 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Part No. AX1266-1 AX1263-1 AX1252-1 Preparative HPLC Columns and Flash Chromatography Flash Purification • Excellent purification performance of UV-active compounds at different wavelengths • Eliminates uncontrolled sample loss to ensure sample security and retention • Method-guiding functionality optimizes solvent, column and gradient options to increase efficiency and flexibility • Ready-to-Run technology reduces downtime The 971-FP system enhances productivity through its ready-to-run technology that eliminates warmup time, performs self diagnostics to ensure proper operation, supplies helpful navigation run start software and introduces walk-away start features like system auto-prime and sample auto-inject. The instrument incorporates the latest compound separation innovations, and contains new sample security and retention technology. Solutions Description 971-FP multiple wavelength UV flash chromatography workstation Includes advanced features pack (AFP) 971-FP single wavelength UV flash chromatography workstation Part No. AX1600-1 AX1605-1 LC AND LC/MS COLUMNS 943 Preparative HPLC Columns and Flash Chromatography Instrument Supplies Agilent offers several accessories to support the 971-FP, including a Multi-column Controller to connect additional stations for uninterrupted column operation. The Advanced Feature Package (AFP) offers uninterrupted solvent supply, waste level monitoring and feedback, Guide Me functionality and dynamic run queues for multi-column control capacity. A high-speed processor and advanced operating software are integral to the AFP. The integral fume enclosure traps solvent fumes for use in areas without hoods (requires a 4 in. or greater exhaust ventilation connection), and the solvent bottle safety tray provides additional support of storing 4 L solvent bottles. Instrument Supplies Description MCC2 – Multi-column controller Advanced feature package (AFP) Integral fume enclosure Solvent bottle safety tray Part No. AX1426-1 AX1440-1 AX1429-1 AX1441-1 Accessory Racks A variety of accessory racks for the 971-FP, all with radio frequency identification (RFID), is available. Accessory Racks Description 13 x 100 mm rack, holds 90 tubes 16 x 100 mm rack, holds 60 tubes 16 x 150 mm rack, holds 60 tubes 18 x 150 mm rack, holds 40 tubes 25 x 150 mm rack, holds 24 tubes 944 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Part No. AX1442-1 AX1443-1 AX1444-1 AX1446-1 AX1447-1 GPC/SEC Columns and Calibrants GPC/SEC COLUMNS AND CALIBRANTS Agilent delivers leading solutions for characterizing and separating polymers by GPC/SEC. We manufacture all components for accurate polymer analysis, including columns and standards. With the addition of Varian in 2010, Agilent greatly expanded its GPC/SEC portfolio to include the highly respected PLgel, PolarGel, PlusPore, and PL aquagel-OH column families, as well as an extensive line of polymer standards for GPC/SEC. If you're currently using one of these part numbers for GPC/SEC columns or standards, reorder using the new part number listed below: Cross Reference Guide for GPC/SEC Columns & Standards If you're using... Part No. Reorder this... Description Size (mm) New Part No. PLgel 10 µm guard PLgel 5 µm guard PLgel 10 µm MIXED-B PLgel 10 µm 50Å PLgel 10 µm 100Å PLgel 10 µm 500Å PLgel 10 µm 103Å PLgel 10 µm 104Å PLgel 10 µm 105Å PLgel 10 µm 106Å PLgel 20 µm MIXED-A PLgel 3 µm MIXED-E PLgel 5 µm MIXED-C PLgel 5 µm MIXED-D PLgel 5 µm 50Å PLgel 5 µm 100Å PLgel 5 µm 500Å PLgel 5 µm 103Å PLgel 5 µm 104Å PLgel 5 µm 105Å 7.5 x 50 7.5 x 50 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 PL1110-1120 PL1110-1520 PL1110-6100 PL1110-6115 PL1110-6120 PL1110-6125 PL1110-6130 PL1110-6140 PL1110-6150 PL1110-6160 PL1110-6200 PL1110-6300 PL1110-6500 PL1110-6504 PL1110-6515 PL1110-6520 PL1110-6525 PL1110-6530 PL1110-6540 PL1110-6550 Organic GPC 79911GP-110 79911GP-510 79911GP-MXB 79911GP-100 79911GP-101 79911GP-102 79911GP-103 79911GP-104 79911GP-105 79911GP-106 79911GP-MXA 79911GP-MXE 79911GP-MXC 79911GP-MXD 79911GP-500 79911GP-501 79911GP-502 79911GP-503 79911GP-504 79911GP-505 (Continued) LC AND LC/MS COLUMNS 945 GPC/SEC Columns and Calibrants Cross Reference Guide for GPC/SEC Columns & Standards If you're using... Part No. Reorder this... Description Size (mm) New Part No. 7.5 x 300 7.5 x 50 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 PL1120-6830 PL1149-1840 PL1149-6800 PL1149-6840 PL1149-6850 PL1149-6860 Aqueous SEC of Polymers 79911GF-083 79911GF-080 79911GF-MXA 79911GF-084 79911GF-085 79911GF-086 PL aquagel-OH 30 8 µm PL aquagel-OH 8 µm guard PL aquagel-OH MIXED-H 8 µm PL aquagel-OH 40 8 µm PL aquagel-OH 50 8 µm PL aquagel-OH 60 8 µm Polymer Standards for GPC/SEC 79911-60500 79911-60501 79911-60502 5064-8281 1535-4545 5064-8280 1535-4546 946 LC AND LC/MS S-L-10 polystyrene calibration kit, 10 x 0.5 g S-M-10 polystyrene calibration kit, 10 x 0.5 g S-H-10 polystyrene calibration kit, 10 x 0.5 g EasiVial PS-H, pre-weighted calibration kit Polyethylene glycol/oxide calibration kits, PEG-10, 10 x 0.5 g EasiVial PEG/PEO, pre-weighted calibration kit Polyacrylic acid - Na salt calibration kit, PAA-10, 10 x 0.2 g www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 PL2010-0101 PL2010-0100 PL2010-0103 PL2010-0201 PL2070-0100 PL2080-0201 PL2140-0100 GPC/SEC Columns and Calibrants Organic GPC PLgel GPC Columns • Robust performance under the most exacting conditions • Temperature stability up to 220°C • Solvent compatibility allows easy and rapid transfer between solvents of varying polarity PLgel materials have high pore volume and high efficiency to maximize resolution. Their unequalled solvent compatibility makes for easy transfer between polar and non-polar eluents, and outstanding physical rigidity provides extended lifetimes that minimize downtime. The key to successful GPC separations is the correct choice of columns. The comprehensive range of PLgel products has been designed to cover virtually all organic solvent-based polymer analysis application areas, and to make selection of the correct column, solvent and calibration standard fast and reliable. PLgel is a highly cross-linked, porous polystyrene/divinylbenzene matrix, which is recognized as a market leader in GPC column technology. PLgel is manufactured to ISO 9001:2000 and benefits from comprehensive QC/QA for total reproducibility, batch-to-batch and column-to-column. Tips & Tools More information is a click away. We have a variety of educational primers, application notes, maintenance guides, and literature available from Agilent for free. To learn more, visit www.agilent.com/chem/OnlineLibrary LC AND LC/MS COLUMNS 947 GPC/SEC Columns and Calibrants Solvent Compatibility Solvent Polarity 6.0 7.3 8.2 8.9 9.1 9.1 9.3 9.3 9.7 9.8 9.9 10.0 10.0 10.2 10.2 10.7 10.8 11.3 12.0 12.1 Solvent Perfluoroalkane Hexane Cyclohexane Toluene Ethyl acetate Tetrahydrofuran (THF) Chloroform Methyl ethyl ketone (MEK) Dichloromethane Dichloroethene Acetone o-Dichlorobenzene (o-DCB) Trichlorobenzene (TCB) m-Cresol o-Chlorophenol (o-CP) Pyridine Dimethyl acetamide (DMAc) n-Methyl pyrolidone (NMP) Dimethyl sulfoxide (DMSO) Dimethyl formamide (DMF) Tips & Tools Don't forget, we have special offers throughout the year. To learn more, visit www.agilent.com/chem/specialoffers 948 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 GPC/SEC Columns and Calibrants PLgel MIXED Columns The PLgel MIXED range greatly simplifies column selection for easy decision making. Using these mixed columns you can eliminate mismatched column sets and spurious peaks for more reliable results. Every column contains a mixture of individual pore size materials, accurately blended to cover a specified broad range of molecular weight with a linear calibration to eliminate column mismatch. Simply add extra columns for even greater resolution. Column Specifications Column MIXED-A Linear MW Operating Range (g/mol) 2,000-40,000,000 Guaranteed Column Efficiency > 17,000 p/m MIXED-B 500-10,000,000 > 35,000 p/m MIXED-C 200-2,000,000 > 50,000 p/m MIXED-D 200-400,000 > 50,000 p/m MIXED-E up to 30,0000 7.5 x 300 mm: > 80,000 p/m 4.6 x 250 mm: > 70,000 p/m Typical Pressure 1 mL/min (7.5 mm ID): ≈ 3 bar (44 psi) per 300 mm 0.3 mL/min (4.6 mm ID): ≈ 2.4 bar (35 psi) per 250 mm (THF @ 20°C, TCB @ 140°C) 1 mL/min (7.5 mm ID): ≈ 10 bar (145 psi) per 300 mm 0.3 mL/min (4.6 mm ID): ≈ 8 bar (116 psi) per 250 mm (THF @ 20°C, TCB @ 140°C) 1 mL/min (7.5 mm ID): ≈ 30 bar (435 psi) per 300 mm 0.3 mL/min (4.6 mm ID): ≈ 24 bar (348 psi) per 250 mm (THF @ 20°C, TCB @ 140°C) 1 mL/min (7.5 mm ID): ≈ 30 bar (435 psi) per 300 mm 0.3 mL/min (4.6 mm ID): ≈ 24 bar (348 psi) per 250 mm (THF @ 20°C, TCB @ 140°C) 1 mL/min (7.5 mm ID): ≈ 50 bar (725 psi) per 300 mm 0.3 mL/min (4.6 mm ID): ≈ 42 bar (609 psi) per 250 mm (THF @ 20°C) Maximum Flow Rate 7.5 mm ID: 1.5 mL/min 4.6 mm ID: 0.5 mL/min Maximum Pressure 150 bar (2175 psi) Maximum Temperature 220°C 7.5 mm ID: 1.5 mL/min 4.6 mm ID: 0.5 mL/min 150 bar (2175 psi) 220°C 7.5 mm ID: 1.5 mL/min 4.6 mm ID: 0.5 mL/min 150 bar (2175 psi) 150°C 7.5 mm ID: 1.5 mL/min 4.6 mm ID: 0.5 mL/min 150 bar (2175 psi) 150°C 7.5 mm ID: 1.5 mL/min 4.6 mm ID: 0.5 mL/min 180 bar (2611 psi) 110°C LC AND LC/MS COLUMNS 949 GPC/SEC Columns and Calibrants PLgel MIXED Column Selection Guide UHMW polymer distributions PLgel MIXED-A, 20 µm High MW polymers, demanding eluents PLgel MIXED-B, 10 µm Mid range MW polymers, high resolution PLgel MIXED-C, 5 µm Resins, condensation polymers PLgel MIXED-D, 5 µm Low MW resins, prepolymers PLgel MIXED-E, 3 µm 102 107 MW PLgel MIXED Gel Calibration Curves MIXED gel calibration curves are designed to be linear over a specified molecular weight range, ensuring that the same degree of resolution is achieved across the full operating range of the column. The particle size of the packing and porosity of a particular MIXED gel column are carefully matched to the MW range and application, thus optimizing performance and eliminating the effects of shear degradation. Resolution in GPC is controlled by the slope of the calibration curve and the particle size of the packing material. Agilent has scientifically determined the minimum number of MIXED gel columns required to perform accurate MWD determinations based on specific resolution (Rsp). Thus you can have complete confidence in the accuracy and precision of the calculated data. Key MIXED-A, 20 µm 10 M Polystyrene Molecular Weight MIXED-B, 10 µm MIXED-C, 5 µm MIXED-D, 5 µm MIXED-E, 3 µm 1K 4 Elution Volume (mL) 10 VLC0014 Reference: Meehan, E. (1998) Size exclusion chromatography columns from Polymer Laboratories. In: Chi-San Wu (Ed.) Column Handbook for Size Exclusion Chromatography. Academic Press, New York, USA. 950 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 GPC/SEC Columns and Calibrants PLgel MIXED Columns Description PLgel 20 µm MIXED-A PLgel 10 µm MIXED-B PLgel 5 µm MIXED-C PLgel 5 µm MIXED-D PLgel 3 µm MIXED-E Size (mm) 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 Part No. PL1110-6200 PL1110-6100 PL1110-6500 PL1110-6504 PL1110-6300 Particle Size (µm) 20 10 5 3 Part No. PL1110-1220 PL1110-1120 PL1110-1520 PL1110-1320 PLgel MIXED Guards Size (mm) 7.5 x 50 7.5 x 50 7.5 x 50 7.5 x 50 LC AND LC/MS COLUMNS 951 GPC/SEC Columns and Calibrants PLgel MIXED-LS Columns • Obtain an instant improvement in data quality • No need for conditioning, saving time and solvent costs • Maximize the potential of light scattering detectors The PLgel MIXED-LS series is a PS/DVB packing using an innovative proprietary suspension polymerization technique to virtually eliminate nano-particle leakage. A startling improvement is achieved immediately in the quality of light scattering data obtained with PLgel MIXED-LS columns in place of conventional GPC columns. The light scattering chromatograms shown here were obtained after flushing the columns for one hour in THF at 1 mL/min. A polystyrene standard (Mp 210,000) was injected at 1 mg/mL in order to illustrate the dramatic improvement in signal-to-noise with the PLgel MIXED-LS column. The performance of PLgel MIXED-LS columns has been matched to PLgel 20 µm MIXED-A and PLgel 10 µm MIXED-B columns in terms of calibration, column efficiency, wide solvent compatibility and operating temperature. MIXED-LS are also ideal for online viscosity detection, minimizing the risk of capillary blockage, and can be used with regular PLgel guard columns that are packed with rigid low pore size gels with no particle bleed. PLgel MIXED-LS Columns Description PLgel 10 µm MIXED-B LS PLgel 10 µm guard PLgel 20 µm MIXED-A LS PLgel guard 20 µm 952 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com Size (mm) 7.5 x 300 7.5 x 50 7.5 x 300 7.5 x 50 Linear MW Guaranteed Operating Range Efficiency (g/mol) (PS) (p/m) 500-10,000,000 > 35,000 2,000-40,000,000 l 01357 522 961 > 17,000 Part No. PL1110-6100LS PL1110-1120 PL1110-6200LS PL1110-1220 GPC/SEC Columns and Calibrants Conventional GPC column Column: Conventional GPC column Mobile Phase: Flow Rate: Detector: THF 1.0 mL/min LS 60 min 60 min 70 PLgel LS column Column: PLgel 10 µm MIXED-B LS PL1110-6100LS 7.5 x 300 mm, 10 µm Mobile Phase: Flow Rate: Detector: THF 1.0 mL/min LS 70 VLC0015 LC AND LC/MS COLUMNS 953 GPC/SEC Columns and Calibrants PLgel MiniMIX Columns • Use about 70% less solvent and save money • Store less solvent and increase operator safety • High performance comparable to Agilent's conventional ID columns For reduced solvent cost and consumption, use industry standard PLgel MiniMIX mixed gel columns in 250 x 4.6 mm narrow bore dimensions. These narrow bore columns offer high performance, excellent solvent compatibility and mechanical stability. PLgel MiniMIX columns can be used with conventional GPC equipment. To maintain the same linear velocity through the column, the volumetric flow rate must be reduced to 0.3 mL/min in line with the column cross sectional area, resulting in significantly lower solvent consumption. Sample loading should also be scaled down in line with reduced column volume, and system dead volume should be minimized to avoid excessive band broadening. PLgel MiniMIX Columns Description PLgel 20 µm MiniMIX-A PLgel 20 µm MiniMIX-A guard PLgel 10 µm MiniMIX-B Plgel 10 µm MiniMIX-B guard PLgel 5 µm MiniMIX-C PLgel 5 µm MiniMIX-C guard PLgel 5 µm MiniMIX-D PLgel 5 µm MiniMIX-D guard PLgel 3 µm MiniMIX-E PLgel 3 µm MiniMIX-E guard 954 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com Size (mm) 4.6 x 250 4.6 x 50 4.6 x 250 4.6 x 50 4.6 x 250 4.6 x 50 4.6 x 250 4.6 x 50 4.6 x 250 4.6 x 50 Linear MW Guaranteed Operating Range Efficiency (g/mol) (PS) (p/m) 2,000-40,000,000 > 17,000 l 01357 522 961 500-10,000,000 > 35,000 200-2,000,000 > 50,000 200-400,000 > 50,000 up to 30,000 > 70,000 Part No. PL1510-5200 PL1510-1200 PL1510-5100 PL1510-1100 PL1510-5500 PL1510-1500 PL1510-5504 PL1510-1504 PL1510-5300 PL1510-1300 GPC/SEC Columns and Calibrants PLgel Individual Pore Size Columns • Very high efficiency improves productivity • Choose the optimum column for a perfect match of performance and application • Fast analysis with fewer columns saves time and money Individual pore size GPC columns offer high resolution over a specific molecular weight range. The linear portion of the calibration curve, where the slope is at its shallowest, defines the MW region over which optimum resolution will be achieved. PLgel Individual Pore Size Columns Size (mm) 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 Calibration curves Linear MW Operating Range (g/mol) (PS) up to 4,000 up to 2,000 up to 4,000 500-30,000 500-60,000 10,000-600,000 60,000-2,000,000 up to 2,000 500-30,000 500-30,000 500-60,000 500-60,000 10,000-600,000 60,000-2,000,000 Pore Size (Å) 100 50 100 500 103 104 105 50 100 500 103 104 105 106 Guaranteed Efficiency (p/m) > 100,000 > 60,000 > 60,000 > 60,000 > 50,000 > 50,000 > 50,000 > 35,000 > 35,000 > 35,000 > 35,000 > 35,000 > 35,000 > 35,000 Part No. PL1110-6320 PL1110-6515 PL1110-6520 PL1110-6525 PL1110-6530 PL1110-6540 PL1110-6550 PL1110-6115 PL1110-6120 PL1110-6125 PL1110-6130 PL1110-6140 PL1110-6150 PL1110-6160 10 M Polystyrene THF 1.0 mL/min 106 Å Polystyrene Molecular Weight Calibrant: Mobile Phase: Flow Rate: Particle Size (µm) 3 5 5 5 5 5 5 10 10 10 10 10 10 10 105 Å 104 Å 103 Å 500 Å 100 Å 50 Å 1K 4 Elution Volume (mL) 10 VLC0016 LC AND LC/MS COLUMNS 955 GPC/SEC Columns and Calibrants PLgel Preparative Columns • Excellent column efficiency provides optimum resolution • High loading can isolate mg amounts for further study • Over 10 times scale up permits efficient quantification Preparative GPC is generally employed to fractionate polymers, isolate components in a polymer formulation or simplify mixtures of relatively small molecules in complex matrices. Mixtures of materials are easily separated on the basis of size, preferably in a low boiling organic solvent. They are then collected as a series of discrete fractions and isolated by simple evaporation of the solvent. PLgel preparative columns are packed with the same rigid, high performance media as the analytical columns. The 10 µm particle provides high column efficiency (> 25,000 p/m) for optimum resolution and loading characteristics. PLgel 25 mm ID preparative columns offer over 10 times scale-up compared to the 7.5 mm analytical columns. The increased ID and column volume permit even higher loading. With low molecular weight materials, sample concentration can also be significantly increased, enabling production of milligram quantities of very pure material. The actual loading is ultimately controlled by the sample and its molecular weight. PLgel Preparative Columns Size (mm) 25 x 300 25 x 300 25 x 300 25 x 300 25 x 300 25 x 300 25 x 300 MIXED-B 25 x 300 MIXED-D 25 x 300 Prep guard 25 x 25 956 LC AND LC/MS Particle Size (µm) 10 10 10 10 10 10 10 10 www.agilent.com/chem/lccolumns www.crawfordscientific.com Pore Size (Å) 50 10 500 103 104 105 106 10 Linear MW Operating Range (g/mol) (PS) up to 2,000 up to 4,000 500-30,000 500-60,000 10,000-600,000 60,000-2,000,000 600,000-10,000,000 500-10,000,000 Part No. PL1210-6115 PL1210-6120 PL1210-6125 PL1210-6130 PL1210-6140 PL1210-6150 PL1210-6160 PL1210-6100 200-400,000 PL1210-6104 PL1210-1120 l 01357 522 961 GPC/SEC Columns and Calibrants Columns for Special GPC/SEC Applications EnviroPrep • High sample loading ensures effective trace analysis • Simple clean-up procedure saves sample preparation costs • Optimized particle size distribution provides high resolution EnviroPrep columns permit a simple, one stage clean-up as part of a methodology to determine pesticides in many organic matrices. The higher molecular weight fractions such as lipids, polymers, natural resins and dispersed high molecular weight components are easily eliminated in the GPC analysis. Preparative GPC for soil extract clean-up is described in EPA Method 3640A using 300 x 25 mm and 150 x 25 mm columns to give higher sample loading and fraction yields, which is particularly useful for low levels of pollutants. Low pore size EnviroPrep columns are ideal for this method. The columns have 10 µm particles with 100Å pore sizes for high resolution, with an exclusion limit of 4000 MW. The preparative columns offer good resolution and high loading through optimization of the particle size distribution. EnviroPrep Size (mm) 21.2 x 150 25 x 150 21.2 x 300 25 x 300 Part No. PL1E10-3120EPA PL1210-3120EPA PL1E10-6120EPA PL1210-6120EPA Columns for sample clean-up Column: Column: Mobile Phase: Flow Rate: Detector: 1 EnviroPrep PL1210-6120EPA 25 x 300 PL1210-3120EPA 25 x 150 3 DCM 10 mL/min UV, 254 nm 1. 2. 3. 4. 5. Corn oil, 25,000 mg/L Bis(2-ethylhexyl) phthalate, 1,000 mg/L Methoxychlor, 200 mg/L Perylene, 20 mg/L Sulfur, 80 mg/L 2 4 0 min 5 22 VLC0017 LC AND LC/MS COLUMNS 957 GPC/SEC Columns and Calibrants PLgel Olexis • Optimized design for polyolefin analysis • High temperature capability • High resolution with no damage from sample shear provides clean separations PLgel Olexis is designed for the analysis of very high molecular weight polymers, specifically polyolefins. The column resolves up to 100,000,000 g/mol (polystyrene in THF), and is packed with 13 µm particles to optimize efficiency and resolution without the risk of sample shear degradation during analysis. The packing of PLgel Olexis has the mechanical stability and robustness expected from a PLgel column, and so it is able to operate up to 220°C for the analysis of highly crystalline materials. PLgel Olexis Description PLgel Olexis PLgel Olexis guard Column: 3 x PLgel Olexis, 7.5 x 300 mm PL1110-6400 Mobile Phase: Flow Rate: Injection Volume: Temperature: Detector: Trichlorobenzene + 0.0125% BHT 1.0 mL/min 200 µL 160°C PL-GPC 220 (RI) Part No. PL1110-6400 PL1110-1400 1 dw/dlog M PLgel Olexis reveals true modalities across the range of polyolefins Size (mm) 7.5 x 300 7.5 x 50 0 3 Log M 7 VLC0018 958 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 GPC/SEC Columns and Calibrants PL HFIPgel • Optimized separation range delivers high performance with no artifacts • Highly durable packing prolongs column lifetime • Low operating pressure reduces system wear and unnecessary downtimes Hexafluoroisopropanol (HFIP) is used as a solvent in GPC for the analysis of important industrial polymers such as polyesters, polyamides and polylactide/glycolide copolymers. For greatly improved performance in extremely polar solvents such as HFIP and trifluoroethanol, we have developed novel "multipore" technology to produce PL HFIPgel, a PS/DVB packing featuring a monodisperse particle size, high pore volume and high resolution. Using PL HFIPgel avoids issues associated with conventional packing and HFIP, such as excessive curvature of calibration curves, dislocations/shoulders on peaks for polydisperse samples and poor resolution in the low MW region. Column efficiency is guaranteed > 30,000 p/m and the columns are very durable, with a maximum operating pressure of 145 bar (2030 psi). They are packed and tested in methanol but shipped ready-to-use in HFIP. PL HFIPgel columns with 7.5 mm ID normally operate at 1 mL/min. However, the 4.6 mm ID columns run at 0.3 mL/min, providing a 70% reduction in solvent consumption with consequent savings in the cost of buying and disposing of solvents. LC AND LC/MS COLUMNS 959 GPC/SEC Columns and Calibrants PL HFIPgel Description PL HFIPgel PL HFIPgel PL HFIPgel guard PL HFIPgel guard Size (mm) 4.6 x 250 7.5 x 300 7.5 x 50 4.6 x 50 Part No. PL1514-5900HFIP PL1114-6900HFIP PL1114-1900HFIP PL1514-1900HFIP Polyamides Column: 2 x PL HFIPgel, 7.5 x 300 mm PL1110-6400 Mobile Phase: Flow Rate: Temperature: Detector: HFIP + 20mM NaTFAc 1.0 mL/min 40°C PL-GPC 50 Plus (RI) Nylon 66 Nylon 6 PBT 5 min 22 VLC0019 960 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 GPC/SEC Columns and Calibrants PL Rapide • Analysis in less than ten minutes saves time • Significantly increased sample throughput improves efficiency • Reduced solvent consumption and disposal costs save money • Available in L, M and H versions for low, medium and high molecular weights; available in F version for flow injection analysis Rapid GPC is an excellent tool for screening polymer MWD for trend analysis. Short PL Rapide columns reduce analysis times while maintaining the excellent solvent compatibility and mechanical stability of all GPC columns from Agilent. PL Rapide columns are ideal for high speed applications such as high throughput screening, process monitoring, or tracking changes in MW distributions, where time is the most critical factor in the analysis. Packed with high quality gels, these columns cover the complete spectrum of molecular weights and are available for the analysis of both organic and water soluble polymers. Key features include high pore volume and high resolution packing materials, no special system requirements, choice of molecular weight resolving range, wide solvent compatibility, and excellent mechanical stability. Tips & Tools Agilent offers a variety of e-Seminars and on-site training to help you learn how to be a more effective chromatographer. For more information, visit www.agilent.com/chem/education LC AND LC/MS COLUMNS 961 GPC/SEC Columns and Calibrants PL Rapide MW Range Guaranteed Size (mm) (g/mol) Efficiency (p/m) 7.5 x 150 500-10,000,000 > 35,000 10 x 100 Description PL Rapide H Part No. PL1113-3100 PL1013-2100 PL Rapide M 7.5 x 150 10 x 100 200-2,000,000 > 60,000 PL1113-3500 PL1013-2500 PL Rapide L 7.5 x 150 10 x 100 200-400,000 > 80,000 PL1113-3300 PL1013-2300 PL Rapide F 7.5 x 150 10 x 100 up to 4,500 up to 4,000 > 55,000 > 40,000 PL1113-3120 PL1013-2120 PL Rapide Aqua H 7.5 x 150 10 x 100 100-10,000,000 > 35,000 PL1149-3800 PL1049-2800 PL Rapide Aqua L 7.5 x 150 10 x 100 100-30,000 > 35,000 PL1120-3830 PL1020-2830 Resin analysis by rapid GPC Column: PL Rapide L PL1013-2300 10 x 100 mm Sample: Mobile Phase: Flow Rate: Detector: Epoxy resin THF 1.0 , 2.0 and 3.0 mL/min UV, 254 nm 1.0 mL/min 2.0 mL/min 3.0 mL/min 0 min 6 VLC0020 962 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 GPC/SEC Columns and Calibrants PolarGel • Medium polarity surface and high mechanical stability • Operate in a wide range of solvents and solvent combinations • Available in two resolving ranges, PolarGel-L and PolarGel-M The PolarGel range is ideal for use with polar solvents, such as dimethyl formamide (DMF) and dimethyl sulfoxide (DMSO), and for solvent combinations such as tetrahydrofuran with water. These eluents are very useful in GPC/SEC to separate polar materials, such as polar resins, modified polysaccharides or complex polar polymers that are difficult to analyze in traditional SEC solvents, such as tetrahydrofuran alone. PolarGel-L is used for low molecular weight polar polymers and PolarGel-M for high MW polar polymers. With polar polymers, highly polar groups can lead to non-specific interactions and secondary separation mechanisms when using polar solvents and traditional non-polar styrene/divinylbenzene columns. Additives and/or column conditioning are normally required to reduce these interactions. PolarGel has no need for these interventions, and also avoids the interactions and secondary effects that produce chromatogram distortions. These PolarGel "mixed bed" columns have a medium polarity surface and high mechanical stability. They are capable of operating in a wide range of solvents and solvent combinations, greatly enhancing your ability to analyze polar polymers that are not necessarily water soluble. PolarGel is available in two resolving ranges to meet your precise requirements. PolarGel Description PolarGel-L PolarGel-L guard PolarGel-L repair gel PolarGel-M PolarGel-M guard PolarGel-M repair gel Size (mm) 7.5 x 300 7.5 x 50 7.5 x 300 7.5 x 50 Part No. PL1117-6830 PL1117-1830 PL1417-0830 PL1117-6800 PL1117-1800 PL1417-0800 LC AND LC/MS COLUMNS 963 GPC/SEC Columns and Calibrants Two samples of melamine resin analyzed by PolarGel-L Column: 2 x PolarGel-L, 300 x 7.5 mm PL1117-6830 Mobile Phase: Flow Rate: Injection Volume: Detector: Dimethylacetamide + 0.1% LiBr 1.0 mL/min 100 µL Agilent PL-GPC 220 (RI) 0 min 22 VLC0021 Excellent separation of two phenol formaldehyde resins with PolarGel-M Column: 2 x PolarGel-M, 300 x 7.5 mm PL1117-6800 Mobile Phase: 0.2% (w/v) DMF & 0.1% LiBr to reduce sample aggregation Flow Rate: 1.0 mL/min Injection Volume: 100 µL Detector: Agilent PL-GPC 50 (RI) 0 min 22 VLC0022 964 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 GPC/SEC Columns and Calibrants PlusPore The PlusPore range has an increased pore volume that provides high resolution for specific applications. The high stability media permits the use of a wide range of organic solvents with accuracy and precision so that there is no distortion of the MW distribution shape. The PlusPore series of columns has been specifically designed for high resolution GPC, and represents the very latest in GPC column technology. These novel packing materials are based on the industry standard, highly cross-linked polystyrene/divinylbenzene (PS/DVB), for the widest applicability and solvent compatibility. Each is made using a novel polymerization process to produce particles that exhibit a specific, controlled pore structure for optimum GPC performance. Typical applications include resins, condensation polymers, prepolymers, and oligomers. For high resolution polymer analysis, the PolyPore, ResiPore, MesoPore and OligoPore columns of the PlusPore product series exhibit a wide pore size distribution with near linear calibration curves covering an extended molecular weight range. These so-called "multipore" structures have increased pore volume compared to regular PS/DVB packing materials. This results in very high resolution GPC columns designed for specific application areas. The highly cross-linked porous particles provide excellent chemical and physical stability and permit easy transfer across the full range of organic solvents with little change in the shape of the calibration curve or the efficiency of the columns. As this multipore column technology does not require the combination of individual pore size packing materials, the result is high accuracy and precision without any artifacts in the shape of the molecular weight distribution. LC AND LC/MS COLUMNS 965 GPC/SEC Columns and Calibrants PlusPore calibration curves Key 6.5 PolyPore ResiPore Log MW MesoPore OligoPore 2 Retention time/min 4 10 VLC0023 PlusPore Selection Guide Column PolyPore ResiPore MesoPore OligoPore 966 MW Range (g/mol) (PS) 200-2,000,000 200-400,000 up to 25,000 up to 4,500 LC AND LC/MS Nominal Particle Size (µm) 5 3 3 6 Typical Efficiency (p/m) > 60,000 > 80,000 > 80,000 > 55,000 www.agilent.com/chem/lccolumns www.crawfordscientific.com Recommended Calibrants EasiCal PS-1or EasiVial PS-H EasiCal PS-2 or EasiVial PS-M Polystyrene S-L-10 Kit Polystyrene S-L2-10 Kit l 01357 522 961 Frit Porosity (µm) 2 2 2 2 GPC/SEC Columns and Calibrants PolyPore • Routine polymer analysis with very high resolution • Wide operating range simplifies column choice • Low particle size extracts maximum information from the analyte PolyPore columns have been specifically developed to give unrivaled resolution for the analysis of polymers with broad molecular weight distributions. With a wide operating range covering many decades of molecular weight, PolyPore columns combine a low 5 µm particle size with extremely high pore volume to give the highest possible resolution, ensuring the most detailed information possible from your analysis. PolyPore Description PolyPore PolyPore guard Size (mm) 7.5 x 300 7.5 x 50 Part No. PL1113-6500 PL1113-1500 Tips & Tools More information is a click away. We have a variety of educational primers, application notes, maintenance guides, and literature available from Agilent for free. To learn more, visit www.agilent.com/chem/OnlineLibrary LC AND LC/MS COLUMNS 967 GPC/SEC Columns and Calibrants Comparison of PolyPore with conventional individual pore size GPC columns Column: 2 x PolyPore, 300 x 7.5 mm PL1113-6500 Sample: Mobile Phase: Flow Rate: Injection Volume: Detector: High MW Resin THF 1.0 mL/min 100 µL Agilent PL-GPC 50 (RI) Individual Pore Size Columns PolyPore 5 Retention time/min 20 VLC0024 Polymethylmethacrylate in DMF Column: 2 x PolyPore, 7.5 x 300 mm PL1113-6500 Sample: Mobile Phase: Flow Rate: Temperature: Injection Volume: Detector: Commercial PMMA DMF + 0.1% LiBr 1.0 mL/min 80°C 100 µL Agilent PL-GPC 50 (RI) 0 Retention time/min 24 VLC0025 968 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 GPC/SEC Columns and Calibrants ResiPore • Efficient separation of complex molecular weight distributions • Reveals oligomer content to provide a true representation of the sample • High pore volume extracts maximum information from the analyte ResiPore columns are the ideal choice for the analysis of resins and condensation polymers with complex molecular weight distributions that include oligomer content. By combining a low 3 µm particle size and high pore volume, high efficiency ResiPore columns offer maximum resolution of these intermediate molecular weight polymers. ResiPore Description ResiPore ResiPore guard Size (mm) 7.5 x 300 7.5 x 50 Part No. PL1113-6300 PL1113-1300 LC AND LC/MS COLUMNS 969 GPC/SEC Columns and Calibrants Alkyd resin Column: 2 x ResiPore, 7.5 x 300 mm PL1113-6500 Mobile Phase: Flow Rate: Injection Volume: Detector: THF 1.0 mL/min 20 µL UV, 254 nm 5 Retention time/min 20 VLC0026 Polyester Column: 2 x ResiPore, 7.5 x 300 mm PL1113-6500 Mobile Phase: Flow Rate: Injection Volume: Detector: THF 1.0 mL/min 20 µL UV, 254 nm 5 Retention time/min 20 VLC0027 970 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 GPC/SEC Columns and Calibrants MesoPore • Full solvent compatibility with no detrimental effect on efficiency • Low particle size extracts maximum information from the analyte • No MWD dislocations so the distribution is an accurate representation of the sample MesoPore columns have been specifically designed to provide optimum results in the analysis of prepolymers, i.e. polymeric materials with a large oligomeric component. By combining a 3 µm particle size with high pore volume, MesoPore columns give the highest resolution separations for the analysis of low molecular weight polymers, such as prepolymers, resins, polyols and siloxanes. MesoPore Description MesoPore MesoPore guard Size (mm) 7.5 x 300 7.5 x 50 Part No. PL1113-6325 PL1113-1325 Polyurethanes Column: 2 x MesoPore, 7.5 x 300 mm PL1113-6500 Mobile Phase: Flow Rate: Injection Volume: Detector: THF 1.0 mL/min 20 µL Agilent PL-GPC 50 (RI) 5 Retention time/min 22 VLC0028 Polyesterimide Column: 2 x MesoPore, 7.5 x 300 mm PL1113-6500 Mobile Phase: Flow Rate: Injection Volume: Detector: THF 1.0 mL/min 20 µL Agilent PL-GPC 50 (RI) 5 Retention time/min 17 VLC0029 LC AND LC/MS COLUMNS 971 GPC/SEC Columns and Calibrants OligoPore • Near linear calibration curve for best accuracy and precision • Very stable media allows for a wide choice of solvents • Isolation of individual fractions reveals more information from whole samples OligoPore columns have been developed from an innovative new media that exhibits significantly increased pore volumes compared to conventional low pore size GPC columns. The outcome is higher resolution in the oligomeric region. The 300 x 25 mm preparative column offers high resolution at greatly increased loading for effective isolation of individual components. Oligomer fractions collected from the OligoPore preparative column can then be re-injected on analytical columns to check for the purity of the fractions and for comparison with the whole sample. OligoPore Description OligoPore OligoPore OligoPore guard Size (mm) 25 x 300 7.5 x 300 7.5 x 50 Tips & Tools Don't forget, we have special offers throughout the year. To learn more, visit www.agilent.com/chem/specialoffers 972 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Part No. PL1213-6520 PL1113-6520 PL1113-1320 GPC/SEC Columns and Calibrants Analysis of low molecular weight polystyrene and oligomer fractions collected from OligoPore preparative columns Column: 2 x OligoPore, 7.5 x 300 mm PL1113-6500 Mobile Phase: Flow Rate: Detector: THF 1.0 mL/min UV Whole polymer F9 F8 F7 F6 F5 F4 F3 F2 F1 10 Retention time/min 20 VLC0030 Analytical separation of low molecular weight polystyrene Column: 2 x OligoPore, 7.5 x 300 mm PL1113-6500 Mobile Phase: Flow Rate: Loading: Detector: THF 1.0 mL/min 0.2%, 100 mL UV 5 Retention time/min 5 Retention time/min 20 Preparative separation of low molecular weight polystyrene Column: 2 x OligoPore, 25 x 300 mm PL1113-6500 Mobile Phase: Flow Rate: Loading: Detector: THF 10.0 mL/min 2.0%, 2 mL UV 20 VLC0031 LC AND LC/MS COLUMNS 973 GPC/SEC Columns and Calibrants Aqueous SEC of Polymers PL aquagel-OH SEC Aqueous size exclusion chromatography (SEC) is widely used for the determination of molecular weight distributions of a variety of synthetic and naturally occurring water-soluble polymers, and separations of oligomers and small molecules. The requirement to eliminate ionic and hydrophobic effects makes aqueous SEC very demanding. The PL aquagel-OH series provides a chemically and physically stable matrix for reliable aqueous SEC separations. The columns are packed with macroporous copolymer beads with an extremely hydrophilic polyhydroxyl functionality. The "neutral" surface and the capability to operate across a wide range of eluent conditions provide for high performance analyses of compounds with neutral, ionic and hydrophobic moieties, alone or in combination. PL aquagel-OH is available for analytical and preparative applications. Optimizing Conditions for Aqueous SEC with PL aquagel-OH Columns Due to the complex nature of water-soluble polymers, it is often necessary to modify the eluent in order to avoid sample-to-sample and sample-to-column interactions which can result in poor aqueous SEC separations. The excellent stability of the PL aquagel-OH packing material allows the eluent to be tailored to suit the polymer, while retaining the high column efficiency. For ionic interactions, the eluent can be modified by the addition of salt and/or the adjustment of pH. For water soluble polymers with a hydrophobic character, only the addition of a weak organic solvent (methanol) is required to inhibit hydrophobic interactions. 974 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 GPC/SEC Columns and Calibrants Guide to eluent selection for PL aquagel-OH applications Water soluble polymer Polymer Chemistry Suggested Eluent Hydrophobic Polymers Neutral Anionic Cationic Pure Water 0.1-0.3 M NaNO3 pH 7-9 0.01 M NaH2P04 0.2-0.8 M NaNO3 pH 2-7 0.01 M NaH2P04 Addition of up to 50% methanol PL aquagel-OH Column Selection Guide Sample Type Low MW polymers and oligomers Typical Applications Surfactants, oligosaccharides, PEGs, lignosulfonates, polyacrylates Polydisperse synthetic or naturally occurring polymers Polysaccharides, PVA, cellulose derivatives, PEO, polyacrylic acid Very high MW polymers Polyacrylamides, hyaluronic acids, CMC, starches, gums Recommended Column Sets 2 or 3 30, 20 PL aquagel-OH 8 µm, or PL aquagel-OH 20 5 µm, or PL aquagel-OH MIXED-M 8 µm 2 or 3 PL aquagel-OH MIXED-H 8 µm, or PL aquagel-OH 60/50/40 8 µm PL aquagel-OH 60/50/40 15 µm in series LC AND LC/MS COLUMNS 975 GPC/SEC Columns and Calibrants PL aquagel-OH Analytical Tips & Tools Buffers in a stored column may crystallize and cause damage. Flush the column with water containing a small amount of sodium azide to prevent biological growth. • Highly stable matrix ensures reliable separations, even with modified eluents • MIXED columns cover a wide range of molecular weights, simplifying column selection • Highly versatile for neutral, polar, anionic and cationic samples The PL aquagel-OH analytical series has a pH range of 2-10, compatibility with organic solvent (up to 50% methanol), mechanical stability up to 140 bar (2030 psi) and low column operating pressures. PL aquagel-OH Analytical Description PL aquagel-OH 20 5 µm PL aquagel-OH 20 8 µm PL aquagel-OH 30 8 µm PL aquagel-OH 40 8 µm PL aquagel-OH 40 15 µm PL aquagel-OH 50 8 µm PL aquagel-OH 50 15 µm PL aquagel-OH 60 8 µm PL aquagel-OH 60 15 µm PL aquagel-OH MIXED-H 8 µm PL aquagel-OH MIXED-M 8 µm PL aquagel-OH 10 µm guard PL aquagel-OH 5 µm guard PL aquagel-OH 8 µm guard 976 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com Size (mm) 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 7.5 x 300 MW Range (g/mol) (PEG/PEO) 100-20,000 100-20,000 100-30,000 10,000-200,000 10,000-200,000 50,000-1,000,000 50,000-1,000,000 200,000 - > 10,000,000 200,000 - > 10,000,000 100-10,000,000 Guaranteed Efficiency (p/m) > 55,000 > 35,000 > 35,000 > 35,000 > 15,000 > 35,000 > 15,000 > 35,000 > 15,000 > 35,000 Part No. PL1120-6520 PL1149-6820 PL1120-6830 PL1149-6840 PL1149-6240 PL1149-6850 PL1149-6250 PL1149-6860 PL1149-6260 PL1149-6800 100-10,000,000 > 35,000 PL1149-6801 25 x 25 PL1249-1120 7.5 x 50 PL1149-1530 7.5 x 50 PL1149-1840 l 01357 522 961 GPC/SEC Columns and Calibrants Polyvinyl alcohol Column: 3 x PL aquagel-OH MIXED PL1149-6800 7.5 x 300 mm, 8 µm Mobile Phase: Flow Rate: Detector: 0.2 M NaNO3, 0.01 M NaH2PO4, pH 7 1.0 mL/min Agilent PL-GPC 50 (RI) 10 Retention time/min 33 VLC0032 Heparin Column: 2 x PL aquagel-OH 30 PL1120-6830 7.5 x 300 mm, 8 µm Mobile Phase: Flow Rate: Detector: 0.2 M NaNO3, 0.01 M NaH2PO4, pH 7 1.0 mL/min Agilent PL-GPC 50 (RI) 5 Retention time/min 22 VLC0033 LC AND LC/MS COLUMNS 977 GPC/SEC Columns and Calibrants Hyaluronic acid Column: Column: Mobile Phase: Flow Rate: Detector: PL aquagel-OH 60 15 µm PL1149-6260 7.5 x 300 mm, 15 µm PL aquagel-OH 40 15 µm PL1149-6240 7.5 x 300 mm, 15 µm Chromatogram 0.2 M NaNO3, 0.01 M NaH2PO4, pH 7 1.0 mL/min Agilent PL-GPC 50 (RI) 5 min 18 dw/dlog M 1 Mw 1,800,00 g/mol 0 5 Log M 7 VLC0034 2 x PL aquagel-OH 20 PL1120-6520 7.5 x 300 mm, 5 µm Mobile Phase: Flow Rate: Injection Volume: Software: Detector: 0.25 M ammonium formate in water 1.0 mL/min 20 µL Cirrus GPC module for Galaxie CDS ELS (neb=30°C, evap=30°C, gas=1.4 SLM) 1.0 Cum.Ht Column: 8.0 dw/Log M Differences in composition of two alkyl naphthalene sulfonates 0.0 0.0 1.0 Log M 3.5 VLC0035 978 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 GPC/SEC Columns and Calibrants PL aquagel-OH Preparative • Up to 10 times scale-up maximizes yield • High loading maximizes sample throughput • Carefully chosen particle size provides optimum resolution Preparative SEC is used for the fractionation of a wide variety of water-soluble samples based on their size in solution. The technique is applied to the fractionation of disperse polymers or to isolate components in a polymer formulation. Preparative PL aquagel-OH columns and associated guard columns enable rapid and convenient scale-up from analytical separations. The 25 mm ID prep column offers at least a 10 times scale-up in loading from the 7.5 mm ID analytical columns. Typically, a 10 mL/min flow rate results in a separation time of ten minutes with a 300 mm column. The columns are packed with the same robust macroporous particles as the analytical column range. The 8 µm article size provides optimum resolution and loading characteristics with column efficiency > 20,000 plates/m. PL aquagel-OH Preparative Description PL aquagel-OH 30 8 µm PL aquagel-OH 40 8 µm PL aquagel-OH 50 8 µm PL aquagel-OH MIXED 8 µm PL aquagel-OH 10 µm guard Size (mm) 25 x 300 25 x 300 25 x 300 25 x 300 25 x 25 MW Range (g/mol) (PEG/PEO) 100-30,000 10,000-200,000 50,000-1,000,000 100-10,000,000 Part No. PL1220-6130 PL1249-6140 PL1249-6150 PL1249-6100 PL1249-1120 LC AND LC/MS COLUMNS 979 GPC/SEC Columns and Calibrants Polyvinyl alcohol Column: PL aquagel-OH 40 8 µm PL1249-6140 25 x 300 mm, 8 µm Mobile Phase: Flow Rate: Loading: Detector: 0.2 M NaNO3, 0.01 M NaH2PO4, pH 7 10.0 mL/min 10 mg/mL, 2 mL Agilent PL-GPC 50 (RI) Retention time/min 0 15 VLC0036 GPC Column Accessories Description Frit removal tool for threaded columns only 2 µm frit kit for threaded columns, 7.5 mm ID 5 µm frit kit for threaded columns, 7.5 mm ID 10 µm frit kit for threaded columns, 7.5 mm ID PLgel column repair gel, 10 µm PLgel column repair gel, 5 µm Column connecting nuts, 1/16 in. tube Tubing ferrules, 1/16 in. tube Connecting tubing, 10 cm length, 0.01 in. ID LDV intercolumn stainless steel connector 980 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Unit 1/pk 5/pk 5/pk 5/pk 1/pk 1/pk 5/pk 5/pk 10/pk 1/pk Part No. PL1310-0001 PL1310-0002 PL1310-0012 PL1310-0036 PL1410-0101 PL1410-0501 PL1310-0007 PL1310-0008 PL1310-0048 PL1310-0005 GPC/SEC Columns and Calibrants Polymer Standards for GPC/SEC Polymer standards from Agilent are the ideal reference materials for generating accurate, reliable GPC/SEC column calibrations, with the assurance of the ISO 9001:2000 quality standard. Additional applications for our highly characterized homopolymers and copolymers exhibiting unique characteristics are as model polymers for research and analytical method development. Agilent manufactures the highest quality polymer standards with extremely narrow polydispersity and the widest molecular weight range commercially available. These quality polymer standards are supplied with extensive characterization data utilizing a variety of independent techniques (e.g. light scattering and viscometry) and high performance GPC to verify polydispersity and assign that all important peak molecular weight (Mp). Our comprehensive range of EasiVial, EasiCal and traditional calibration kits has been specifically designed to cover all molecular weight ranges for organic and aqueous GPC/SEC applications. We provide you with the widest choice to maximize your specific characterization needs. In addition, we supply other polymers as individual molecular weights, and broad distribution polymers for system validation or broad standard calibration procedures. LC AND LC/MS COLUMNS 981 GPC/SEC Columns and Calibrants Calibration Kits Agilent offers a wide range of polymer standards kits for conventional GPC/SEC column calibration or for calibrating light scattering and viscometry detectors. The kits are in boxed sets of ten different polymer standards covering a particular molecular weight range, to be used with organic and aqueous, medium polarity and polar solvents. Every individual polymer has its own Certificate of Analysis of the analytical conditions and values, such as Mp needed for constructing a calibration plot. The polymers are chosen to give equidistant calibration points on a logarithmic MW scale, providing a more uniform calibration curve. Individual Polymer Molecular Weights We design our individual standards to have the narrowest molecular weight distribution commercially available. Additionally, they cover the widest molecular weight range, from 162-15 million MW. The current polystyrene nominal molecular weight of 15 million MW has a polydispersity ≤1.10. These standards are generally available in 1, 5 and 10 g quantities, and each comes with its own Certificate of Analysis detailing analysis conditions and relevant data. GPC/SEC Standards Selection Guide Polymer Type Polystyrene Polymethylmethacrylate Polyethylene Polyethylene glycol (PEG) Polyethylene oxide (PEO) Pullulan polysaccharide Polyacrylic acid Na salt 982 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com Individual Calibration MW Kits EasiCal EasiVial Type of GPC/SEC ] ] ] ] Organic ] ] ] Organic ] ] Organic ] ] ] Organic/Aqueous ] ] ] Organic/Aqueous ] ] Organic/Aqueous ] ] Aqueous l 01357 522 961 GPC/SEC Columns and Calibrants EasiVial • Eliminates tedious weighing procedures to improve calibration accuracy • Reduces solvent dispensing to limit risks associated with handling solvents • For conventional and multi-detector GPC to maximize applicability For organic and aqueous GPC/SEC column calibration, this premier product is the quickest and most convenient method to deliver an accurate 12-point column calibration. The key to achieving baseline separation from polymer mixtures, therefore eliminating doubt and errors, is in selecting only the narrowest polydispersity polymers. This is where Agilent polymer standards excel and deliver, as shown in the chromatograms. The EasiVial standards kit is a pre-prepared, time saving product for rapid and reliable GPC column calibration. EasiVial kits contain three vials, each with a mixture of four accurately pre-weighed polymer standards, providing a 12-point GPC calibration in just three injections. The mass of each polymer in the vial is accurately known, so that upon addition of a fixed volume of eluent, the solution is prepared at a precise concentration. EasiVial is ideal for both conventional and multi-detector GPC calibration. Simply prepare and manually inject, or transfer to autosampler vials, or place directly into a compatible autosampler. Every EasiVial kit contains 30 vials (ten of each type) that are color-coded for easy identification and are available in 4 or 2 mL vials making them suitable for most autosamplers. The kits are available for polystyrene (PS), polymethylmethacrylate (PMMA), polyethylene glycol/oxide (PEG/PEO) and polyethylene glycol (PEG). For added value, a Tri-Pack (90 vials) is offered, extending reproducibility. Polystyrene calibration generated with EasiVials LogM 1.0e7 1.0e2 15 Retention time/min 29 VLC0044 LC AND LC/MS COLUMNS 983 GPC/SEC Columns and Calibrants EasiVial Pre-weighed Calibration Kits Range of Nominal Mp (g/mol) 100-1,200,000 100-1,200,000 106-35,000 106-35,000 600-2,000,000 600-2,000,000 162-6,000,000 162-6,000,000 162-400,000 162-400,000 162-40,000 162-40,000 Description EasiVial PEG/PEO EasiVial PEG/PEO EasiVial PEG EasiVial PEG EasiVial PM EasiVial PM EasiVial PS-H EasiVial PS-H EasiVial PS-M EasiVial PS-M EasiVial PS-L EasiVial PS-L PEG/PEO Tri-Pack PEG/PEO Tri-Pack PEG Tri-Pack PEG Tri-Pack PMMA Tri-Pack PMMA Tri-Pack PS-H Tri-Pack PS-H Tri-Pack PS-L Tri-Pack PS-L Tri-Pack Vial Volume (mL) 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 2 4 3 4 Unit 30/pk 30/pk 30/pk 30/pk 30/pk 30/pk 30/pk 30/pk 30/pk 30/pk 30/pk 30/pk 90/pk 90/pk 90/pk 90/pk 90/pk 90/pk 90/pk 90/pk 90/pk 90/pk Part No. PL2080-0201 PL2080-0200 PL2070-0201 PL2070-0200 PL2020-0201 PL2020-0200 PL2010-0201 PL2010-0200 PL2010-0301 PL2010-0300 PL2010-0401 PL2010-0400 PL2080-0202 PL2080-0203 PL2070-0202 PL2070-0203 PL2020-0202 PL2020-0203 PL2010-0202 PL2010-0203 PL2010-0402 PL2010-0403 EasiVial PS-H Column: 3 x PLgel MIXED-B, 10 µm PL1110-6100 7.5 x 300 mm, 10 µm Mobile Phase: Flow Rate: Temperature: Detector: THF 1.0 mL/min 40°C PL-GPC 220 (RI) 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 4 3 2 1 7 6 8 5 10 11 12 9 10 min 33 VLC0037 984 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 6,035,000 483,000 19,720 1,260 3,053,000 84,900 8,450 580 915,000 60,450 3,370 162 GPC/SEC Columns and Calibrants EasiCal • Easy three-step process with no fuss • Cost-effective format saves money • Only two injections for improved productivity The EasiCal system for organic solvents consists of two different combs, each with ten detachable spatulas, supporting a mixture of five polymer standards. The thin film of polymer (approximately 5 mg) on the tip of the PTFE spatulas rapidly dissolves when immersed in eluent to provide two GPC/SEC calibration solutions. A single pack provides ten spatulas of each type, with MWs selected to provide equidistant calibration points for greater accuracy. EasiCal Pre-prepared Polystyrene Kits Description Polystyrene PS-1 Range of Nominal Mp (g/mol) 580-7,500,000 Polystyrene PS-2 580-400,000 Unit 1/pk 5/pk 1/pk 5/pk Part No. PL2010-0501 PL2010-0505 PL2010-0601 PL2010-0605 Column calibration for GPC/SEC is as easy as 1, 2, 3... Log MW 7 1. Place one spatula of each type into appropriate volume of solvent. 3 13 Retention time/min 25 VLC0038 3. Generate a 10-point calibration 5 Retention time/min 30 5 Retention time/min 30 2. Chromatograph each solution; only two injections required LC AND LC/MS COLUMNS 985 GPC/SEC Columns and Calibrants Polystyrene • Compatible with most organic solvents • Certificate of Analysis meets international protocols • Calibration capability for virtually all applications Polystyrene standards are the first choice for many organic solvents, either for conventional GPC column calibration or for calibrating light scattering and viscosity detectors. Our organic polymers cover a range from 162-15 million MW, with MWs selected to provide equidistant calibration points for greater accuracy. Every kit contains 0.5 g of ten different molecular weight standards. Calibration Kits Description S-H-10, 10 x 0.5 g S-H2-10, 10 x 0.5 g S-M-10, 10 x 0.5 g S-M2-10, 10 x 0.5 g S-L-10, 10 x 0.5 g S-L2-10, 10 x 0.5 g Range of Nominal Mp (g/mol) 300,000-15,000,000 1,000-15,000,000 580-3,000,000 580-300,000 162-20,000 162-4,500 Tips & Tools More information is a click away. We have a variety of educational primers, application notes, maintenance guides, and literature available from Agilent for free. To learn more, visit www.agilent.com/chem/OnlineLibrary 986 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 Part No. PL2010-0103 PL2010-0104 PL2010-0100 PL2010-0102 PL2010-0101 PL2010-0105 GPC/SEC Columns and Calibrants Individual Polymer Molecular Weights Polymer Nominal Mp (g/mol) 162 370 580 1,000 1,300 2,000 3,000 5,000 7,000 10,000 20,000 30,000 50,000 70,000 100,000 130,000 200,000 300,000 500,000 700,000 1,000,000 1,500,000 2,000,000 2,500,000 4,000,000 7,000,000 10,000,000 15,000,000 1g Part No. PL2012-1001 PL2012-0001 PL2012-2001 PL2012-3001 PL2012-4001 PL2012-5001 PL2012-6001 PL2012-7001 PL2012-8001 PL2012-9001 PL2013-1001 PL2013-2001 PL2013-3001 PL2013-4001 PL2013-5001 PL2013-6001 PL2013-7001 PL2013-8001 PL2013-9001 PL2014-0001 PL2014-1001 PL2014-2001 PL2014-3001 PL2014-4001 PL2014-6001 PL2014-7001 PL2014-8001 PL2014-9001 Nominal Mw/Mn 1.00 1.11 1.11 1.09 1.07 1.05 1.04 1.03 1.04 1.02 1.02 1.02 1.03 1.03 1.02 1.01 1.05 1.03 1.03 1.03 1.05 1.04 1.04 1.05 1.04 1.04 1.06 1.06 5g Part No. PL2012-1005 PL2012-0005 PL2012-2005 PL2012-3005 PL2012-4005 PL2012-5005 PL2012-6005 PL2012-7005 PL2012-8005 PL2012-9005 PL2013-1005 PL2013-2005 PL2013-3005 PL2013-4005 PL2013-5005 PL2013-6005 PL2013-7005 PL2013-8005 PL2013-9005 PL2014-0005 PL2014-1005 PL2014-2005 PL2014-3005 PL2014-4005 PL2014-6005 PL2014-7005 PL2014-8005 PL2014-9005 10 g Part No. PL2012-1010 PL2012-0010 PL2012-2010 PL2012-3010 PL2012-4010 PL2012-5010 PL2012-6010 PL2012-7010 PL2012-8010 PL2012-9010 PL2013-1010 PL2013-2010 PL2013-3010 PL2013-4010 PL2013-5010 PL2013-6010 PL2013-7010 PL2013-8010 PL2013-9010 PL2014-0010 PL2014-1010 PL2014-2010 PL2014-3010 PL2014-4010 PL2014-6010 PL2014-7010 PL2014-8010 PL2014-9010 Polystyrene standards Column: 2 x OligoPore PL1113-6520 7.5 x 300 Mobile Phase: Flow Rate: Detector: THF 1.0 mL/min Agilent PL-GPC 50 (RI) 1,270 580 0 min 20 VLC0039 LC AND LC/MS COLUMNS 987 GPC/SEC Columns and Calibrants Polymethylmethacrylate • Many solvent options increase applicability • Stringent quality control improves performance • Proprietary manufacturing methods ensure consistent supply Polymethylmethacrylate (PMMA) standards are extremely versatile as they can be used for organic GPC with a wide range of medium polarity eluents, such as tetrahydrofuran, toluene, methyl ethyl ketone, and ethyl acetate. They also work well with more polar organic eluents, for example dimethylformamide, dimethylacetamide, and hexafluoroisopropanol. The MWs are selected to provide equidistant calibration points for greater accuracy, covering from 600-1.5 million MW. Every kit contains 0.5 g of ten different molecular weight standards. Calibration Kits Description M-L-10, 10 x 0.5 g M-M-10, 10 x 0.5 g 988 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com Range of Nominal Mp (g/mol) 600-50,000 1,000-1,500,000 l 01357 522 961 Part No. PL2020-0100 PL2020-0101 GPC/SEC Columns and Calibrants Individual Polymer Molecular Weights Polymer Nominal Mp (g/mol) 500 1,000 2,000 3,000 5,000 7,000 10,000 13,000 20,000 30,000 50,000 70,000 100,000 130,000 200,000 300,000 500,000 700,000 1,000,000 15,000,000 Nominal Mw/Mn 1.19 1.26 1.08 1.08 1.09 1.08 1.03 1.03 1.03 1.02 1.02 1.02 1.02 1.05 1.02 1.02 1.06 1.03 1.09 1.09 1g Part No. PL2022-2001 PL2022-3001 PL2022-5001 PL2022-6001 PL2022-7001 PL2022-8001 PL2022-9001 PL2023-0001 PL2023-1001 PL2023-2001 PL2023-3001 PL2023-4001 PL2023-5001 PL2023-6001 PL2023-7001 PL2023-8001 PL2023-9001 PL2024-0001 PL2024-1001 PL2024-2001 5g Part No. PL2022-2005 PL2022-3005 PL2022-5005 PL2022-6005 PL2022-7005 PL2022-8005 PL2022-9005 PL2023-0005 PL2023-1005 PL2023-2005 PL2023-3005 PL2023-4005 PL2023-5005 PL2023-6005 PL2023-7005 PL2023-8005 PL2023-9005 PL2024-0005 PL2024-1005 PL2024-2005 10 g Part No. PL2022-2010 PL2022-3010 PL2022-5010 PL2022-6010 PL2022-7010 PL2022-8010 PL2022-9010 PL2023-0010 PL2023-1010 PL2023-2010 PL2023-3010 PL2023-4010 PL2023-5010 PL2023-6010 PL2023-7010 PL2023-8010 PL2023-9010 PL2024-0010 PL2024-1010 PL2024-2010 Polymethylmethacrylate standards Column: Mobile Phase: Flow Rate: Temperature: Detector: 2 x PL HFIPgel PL1114-6900HFIP 7.5 x 300 3 1 HFIP + 20 mM NaTFAc 1.0 mL/min 40°C Agilent PL-GPC 50 (RI) 1. 2. 3. 4. 5. 4 2 5 5 Retention time/min 790,000 144,000 28,900 5,720 1,020 22 VLC0040 LC AND LC/MS COLUMNS 989 GPC/SEC Columns and Calibrants Polyethylene Glycol/Oxide • Simple-to-use kit form • Combines glycols and oxides to extend the MW range and cover more applications • MWs selected to provide equidistant calibration points for greater accuracy These hydrophilic polymers are suitable for both aqueous SEC and organic GPC using the majority of polar organic solvents. The oxides are available in high molecular weights, while the glycols cover the lower molecular weight range. The two types are chemically similar so they can be used together across a wider molecular weight range, with aqueous and organic polymers from 106-1 million MW. Every kit contains 0.2 g or 0.5 g of ten different molecular weight standards. Calibration Kits Description PEG-10, 10 x 0.5 g PEO-10, 10 x 0.5 g 990 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com Range of Nominal Mp (g/mol) 106-20,000 20,000-1,000,000 l 01357 522 961 Part No. PL2070-0100 PL2080-0101 GPC/SEC Columns and Calibrants Individual Polymer Molecular Weights Polymer Nominal Mp (g/mol) 1g Part No. 5g Part No. 10 g Part No. 1.00 1.00 1.00 1.00 1.09 1.06 1.04 1.04 1.03 1.04 1.05 1.07 1.07 PL2070-1001 PL2070-2001 PL2071-2001 PL2071-3001 PL2070-3001 PL2070-4001 PL2070-5001 PL2070-6001 PL2070-7001 PL2070-8001 PL2070-9001 PL2071-0001 PL2071-1001 PL2070-1005 PL2070-2005 PL2071-2005 PL2071-3005 PL2070-3005 PL2070-4005 PL2070-5005 PL2070-6005 PL2070-7005 PL2070-8005 PL2070-9005 PL2071-0005 PL2071-1005 PL2070-1010 PL2070-2010 PL2071-2010 PL2071-3010 PL2070-3010 PL2070-4010 PL2070-5010 PL2070-6010 PL2070-7010 PL2070-8010 PL2070-9010 PL2071-0010 PL2071-1010 1.05 1.07 1.05 1.05 1.06 1.07 1.07 1.07 1.06 1.07 1.12 1.13 PL2083-1001 PL2083-2001 PL2083-3001 PL2083-4001 PL2083-5001 PL2083-6001 PL2083-7001 PL2083-8001 PL2083-9001 PL2084-0001 PL2084-1001 PL2084-2001 PL2083-1005 PL2083-2005 PL2083-3005 PL2083-4005 PL2083-5005 PL2083-6005 PL2083-7005 PL2083-8005 PL2083-9005 PL2084-0005 PL2084-1005 PL2084-2005 PL2083-1010 PL2083-2010 PL2083-3010 PL2083-4010 PL2083-5010 PL2083-6010 PL2083-7010 PL2083-8010 PL2083-9010 PL2084-0010 PL2084-1010 PL2084-2010 Nominal Mw/Mn Polyethylene Glycol 106 194 238 282 420 600 1,000 1,500 4,000 7,000 10,000 13,000 20,000 Polyethylene Oxide 20,000 30,000 50,000 70,000 100,000 130,000 200,000 300,000 500,000 700,000 1,000,000 1,500,000 Polyethylene Glycol/Oxide standards Column: Mobile Phase: Flow Rate: Detector: PL aquagel-OH MIXED-H 8 µm PL1149-6800 7.5 x 300 mm, 8 µm 1. 2. 3. 4. 5. 3 4 Water 1.0 mL/min Agilent PL-GPC 50 (RI) 2 1 1 Retention time/min 5 1,702,000 120,000 12,600 1,470 106 11 VLC0041 LC AND LC/MS COLUMNS 991 GPC/SEC Columns and Calibrants Polysaccharides • Comprehensive format provides full MW range in one handy kit • Also available as individual standards The pullulan polysaccharides kit consists of several simple sugars with relatively narrow polydispersity linear macromolecules of maltotriose units. Calibration Kits Description SAC-10, 10 x 0.2 g Range of Nominal Mp (g/mol) 180-700,000 Part No. PL2090-0100 Individual Polymer Molecular Weights Polymer Nominal Mp (g/mol) 1,500 2,000 3,000 5,000 20,000 50,000 100,000 200,000 700,000 1,660,000 Unit 0.2 g 0.2 g 0.2 g 0.5 g 0.5 g 0.5 g 0.5 g 0.5 g 0.5 g 0.2 g Part No. PL2091-2000 PL2091-3000 PL2091-4000 PL2090-1000 PL2090-3000 PL2090-4000 PL2090-5000 PL2090-6000 PL2090-8000 PL2091-1000 Pullulan polysaccharide standards Column: Mobile Phase: Flow Rate: Detector: 4 3 x PL aquagel-OH MIXED PL1149-6800 7.5 x 300 mm, 8 µm 1 2 3 5 1. 2. 3. 4. 5. 0.2 M NaNO3, 0.01 M NaH2PO4, pH 7 1.0 mL/min Agilent PL-GPC 50 (RI) 8 Retention time/min 30 VLC0042 992 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961 788,000 212,000 47,300 11,800 667 GPC/SEC Columns and Calibrants Polyethylene • Robust particles provide reliable high temperature calibrations • Two linear molecular weight ranges maximize choice • Short chain branching kit, for FT-IR calibration and TREF/CRYSTAF reference Linear polyethylene standards with low polydispersities (1.01 to 1.9) deliver accurate GPC/SEC calibration curves, from 170-1.5 million MW. The E-MW-10 kit is recommended for polyolefins, and is designed for direct column calibration in solvents such as trichlorobenzene and o-dichlorobenzene from 135-180°C. Every kit contains 0.1 or 0.2 g of ten different molecular weight standards. Short chain branching standards Determination of short chain branching (SCB) as a function of MWD in polyethylene is now possible using high temperature GPC coupled with FT-IR. This series of well-characterized polyethylene SCB standards is a valuable reference set for temperature rising elution fractionation/crystallization analysis fractionation (TREF/CRYSTAF). Calibration Kits Description E-M-10, 10 x 0.2 g E-MW-10, 10 x 0.1 g Range of Nominal Mp (g/mol) 170-120,000 5,000-1,500,000 Polyethylene Short Chain Branching Range of Polmyer Nominal Methyl/ 1000 Total Carbons (NMR) Calibration Kit Part No. PL2650-0101 PL2650-0102 E-SCB, 10 x 0.1 g PL2650-0103 1.27-62.50 Part No. LC AND LC/MS COLUMNS 993 GPC/SEC Columns and Calibrants Individual Polymer Molecular Weights Polymer Nominal Mp (g/mol) 170 282 394 540 750 1,100 2,155 14,000 32,000 120,000 Nominal Mw/Mn 1.00 1.00 1.00 1.09 1.18 1.09 1.14 1.2 1.11 1.19 Unit 1g 1g 1g 1g 1g 1g 1g 0.2 g 0.2 g 0.2 g Part No. PL2650-8001 PL2650-9001 PL2650-0001 PL2650-4001 PL2650-1001 PL2650-2001 PL2650-3001 PL2650-5000 PL2650-6000 PL2650-7000 1g PL2660-7001 0.2 g 0.2 g PL2660-8001 PL2660-9001 Polyethylene Broad MWD Individual Molecular Weights 250,000 9.50 Polyethylene Broad MWD/SCB Individual Molecular Weights 35,000 400,000 5.0 5.0 Polyacrylic Acid • Compatible with all aqueous columns for wide applicability • Aqueous polymers 1,000-1 million MW • Well-characterized Mp values ensure wide utility Calibration Kits Description PAA-10, 10 x 0.2 g 994 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com Range of Nominal Mp (g/mol) 1,000-1,000,000 l 01357 522 961 Part No. PL2140-0100 GPC/SEC Columns and Calibrants Individual Polymer Molecular Weights 0.2 g Part No. PL2142-3000 PL2142-5000 PL2142-6000 PL2142-7000 PL2142-8000 PL2143-0000 PL2143-2000 PL2143-3000 PL2143-4000 PL2143-5000 PL2143-6000 PL2143-7000 PL2143-8000 PL2143-9000 PL2144-0000 PL2144-1000 PL2144-2000 PL2144-3000 Polymer Nominal Mp (g/mol) 1,000 2,000 3,000 5,000 7,000 13,000 30,000 50,000 70,000 100,000 130,000 200,000 300,000 500,000 700,000 1,000,000 1,500,000 2,000,000 1g Part No. PL2142-3001 PL2142-5001 PL2142-6001 PL2142-7001 PL2142-8001 PL2143-0101 PL2143-2001 PL2143-3001 PL2143-4001 PL2143-5001 PL2143-6001 PL2143-7001 PL2143-8001 PL2143-9001 PL2144-0101 PL2144-1001 PL2144-2001 PL2144-3001 Methoxy Polyethylene Glycols (MPEGs) Agilent offers a range of highly characterized, very narrow polydispersity methoxy polyethylene glycols (MPEGs). These very pure polymers are ideal as molecular weight reference materials or for further modification where cross-linking should be avoided. Methoxy Polyethylene Glycols (MPEGs) Polymer Nominal Mp (g/mol) 5,000 10,000 20000 30,000 40,000 50,000 Nominal Mw/Mn 1.03 1.05 1.05 1.06 1.06 1.06 Part No. PL2570-5001 PL2571-0001 PL2572-0001 PL2573-0001 PL2574-0001 PL2575-0001 LC AND LC/MS COLUMNS 995 Biosolutions and Columns for Biologic Characterization AGILENT BIOSOLUTIONS AND COLUMNS FOR BIOLOGIC CHARACTERIZATION Is your lab ready for the ever-increasing number and variety of HPLC applications for biocharacterization and analysis of biomolecules? Basic peptide separations. High-sensitivity, high-resolution amino acid analyses. Fast size exclusion separations of antibodies. The number of bio-HPLC applications continues to grow at an unprecedented rate. Agilent's durable and reproducible line of silica and polymeric bio-HPLC columns can help meet your lab's evolving needs for performance and speed. On the following pages, you will find key facts and specifications for the following columns for bio-HPLC: • Size Exclusion Columns • Ion Exchange Columns • Reversed-Phase Columns for Proteins • Capillary, Nano and MicroBore Columns • Preparative HPLC Columns • Oligo Solutions 996 LC AND LC/MS www.agilent.com/chem/lccolumns www.crawfordscientific.com l 01357 522 961
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2011:04:11 08:51:27+01:00 Creator : Adobe InDesign CS3 (5.0) Modify Date : 2013:05:30 13:36:51-04:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Instance ID : uuid:dc36adeb-606e-e94d-bb8a-d43941348761 Document ID : adobe:docid:indd:888de194-5153-11e0-9269-b1a1f4d325c4 Rendition Class : proof:pdf Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Y Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c, uuid:adf46b1f-8f02-ef48-b60f-09438ea1732c Manifest Reference Document ID : uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537, uuid:afaf8b2d-57c7-6448-b6f9-2f13d8319537 Metadata Date : 2013:05:30 13:36:51-04:00 Creator Tool : Adobe InDesign CS3 (5.0) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 16951 bytes, use -b option to extract) Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Page Count : 462EXIF Metadata provided by EXIF.tools