THE

“WIRELESS” REMOTE

AQUA SMART™ RECEIVER

The heart of the AQUA SMART™ system is the RECEIVER-CONTROL PANEL
(R-CP) which mounts on top of the water heater. The incoming power lines
are routed into the back of R-CP and attached to the water heater supply
lines.
A TEMPERATURE SENSOR is attached to the water heater’s output HOT
water pipe, which relays temperature readings to the transmitter, and then
to the Transmitter which processes the signals and communicates the user
program commands back to the R-CP.
THERMAL SENSOR ATTACHES
TO THE HOT WATER PIPE
AND TO THE R-CP.

CONTOL SYSTEM TO
OPERATE ELECTRIC
HOT WATER HEATERS
REDUCE ELECTRICITY CONSUMPTION AND COSTS WITH
THE INSTALLATION OF A PROGRAMMABLE THERMOSTAT
THAT CONTROLS THE OPERATION OF A RESIDENTIAL
ELECTRIC HOT WATER HEATER.

REDUCE ENERGY
BILLS. SAVE $$$
RECEIVER-CONTROL PANEL (R-CP)
R-CP Mounts
To Top of Hot
Water Heater
Wall-Mounted Transmitter
Water Heate

R-CP MOUNTS TO TOP OF
THE HOT WATER HEATER AND
IS POWERED BY THE INCOMING
POWER SUPPLY TO THE HOT
WATER HEATER.
COPYRIGHT © 2011 AQUA SMART, INC.
PATENT PENDING: US/61440,057
TRADEMARK: 85273759

AQUA SMART, INC.
TH

2425 NW 69 Street
Vancouver, WA 98665
360.699.6194
www.aquaenergysaver.com

TWO-WAY COMMUNICATION
BETWEEN TRANSMITTER and
RECEIVER.
The AQUA SMART™ system RETROFITS to
standard, residential, electric hot water
heaters requiring a minimal of installation
and electrical rewiring.
The AQUA SMART™ can be installed by the
Homeowner, familiar with the wiring of
220V electric hot water heaters and can
be accomplished in less than one hour.
Installation by a certified electrician is also
recommended.

THE

AQUA SMART™ TRANSMITTER

The AQUA SMART™ transmitter easily mounts on a wall. It operates
on 2- AAA alkaline batteries. Wireless, 2-way signals are transmitted
between the transmitter and receiver up to a distance of 80 feet,
depending on structural interferences within the home.

more…..

TRANSMITTER SETTINGS

TEMPERATURE: Readings can be programmed in, °F or °C, at initial set up.
PROGRAM SETTINGS: Program by day, period of day and temperature.
TIME: 12 Hour, AM/PM, clock to be set at initial set up.

LCD – Liquid Crystal Display
VIEW OF TRANSMITTER’S LCD WITH
ALL OPERATING ICONS SHOWING
FOR DEMONSTRATION PURPOSES.

VIEW OF TRANSMITTER LCD IN
NORMAL STATE FOLLOWING
INSTALLATION SET-UP

TRANSMITTER FEATURES
MODES: The AQUA SMART™ system operates on one of 4 MODES.
ON: When engaged in the ON mode, water heater operates, all the
time, at the settings of the “on-board” thermostats on the water
heater. Factory setting for the water heater is normally at 120°F.
AWAY: When engaged in the AWAY mode, the water temperature is
maintained between 75°F and 85°F. This setting is
recommended when the homeowner is to be away from the
home from between 3-7 days, saving energy, but allowing for
faster recovery. Upon return, reset system to a normal mode.
VACATION: When engaged in the VACATION mode, the water temperature
is maintained between 40°F and 50°F. This setting is
recommended when the homeowner to be away from the home
for more than 7 days. Upon return, reset to normal mode.
PROGRAM: When engaged in the PROGRAM mode, water heater operates

at the “set programs” entered by the homeowner at initial set
up. Transmitter has “default”, factory program encrypted into
software which will operate system only in PROGRAM mode.

SENSOR TEMP: Read out of approximate temperature of water in water
heater. Calibration of actual water temperature and sensor
temperature can be “balanced” at initial set up.
KILOWATT USE/MO: At initial set up, homeowner enters his water heater
wattage and then the AQUA SMART™ system records the
energy usage, by month, of the water heater in kilowatt hours
(kWh). Cost of operating water heater can be calculated by
multiplying the kWh times the utility company’s rate charge per
kWh. Each 30 days, this icon readout is reset to zero (0) kWh.
OVERRIDE: User can override the “programmed temperature”, in the
PROGRAM mode, adjusting only the water temperature setting.
The override temperature will remain ‘reset’ until the next
programmed “set temperature” is activated by the transmitter.
TWO-WAY COMMUNICATION: The Transmitter and Receiver have a TWOWAY communication protocol to confirm RF (radio frequency)
signals are being received. When the communication is
interrupted, a WARNING icon flashes on the LCD. Operating
distance for system is up to 80 feet depending on structural
interferences within the home.
LOW BATTERY: Transmitter displays a LOW BATTERY icon to alert
homeowner when it is time to replace batteries. It is suggested
that batteries be replaced every 12-15 months. Transmitter
operates on 2-AAA batteries (included).
LOCKOUT: Transmitter includes security LOCKOUT preventing
unauthorized resetting of system. Homeowner can easily engage
or cancel lockout feature.
SECURITY CODE: Transmitter is factory-programmed with one of 1,048,576
unique security codes to prevent false activation of the system.
At initial set up, user “teaches” security code to the receiver using
the LEARN button on the receiver.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Warning                         : Invalid secondary xref table
Page Count                      : 2
Language                        : en-US
Tagged PDF                      : Yes
Author                          : Owner
Creator                         : Microsoft® Word 2010
Create Date                     : 2012:01:26 00:26:48-06:00
Modify Date                     : 2012:01:26 00:26:48-06:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools

Navigation menu