ZPM3 Spec Zone Paging Module Bogen Specifications Specs
User Manual: Bogen ZPM3 Zone Paging Module Specifications Bogen Amplifiers s - Telecomuserguides.com
Open the PDF directly: View PDF .
Page Count: 2
Download | ![]() |
Open PDF In Browser | View PDF |
Zone Paging Module Model ZPM3 Description Field-programming is used to assign individual zones to the paging zone groups, night ringer zone group, and shift change/emergency-call zone group*. Field-programming is also used to enable/disable the privacy beep for two-way zones, select the shift change/emergency-call tone, and inhibit all-call The ZPM3 works with self-amplified or central-amplified pagoperation. ing systems. A background music source can be connected directly to the ZPM3, or to a separate amplifier that can be A control is included to adjust the volume of the preannounce, confirmation, and shift change/emergency-call used to supply background music to all unpaged zones. tones. Separate controls are provided to adjust the night Built-in DIP switches are used to select the field-programming ringer tone and background music volume. All volume conmode, enable/disable the pre-announce and confirmation trols are screwdriver-adjustable. tones, and set the paging mode (one-way or talk back) of each zone. The Bogen ZPM3 is a telephone-compatible zone paging module with all-call and talk back capabilities serving up to three one- or two-way paging zones.The ZPM3 can also be used in a paging system independent of a telephone system. • 3 Zone paging plus All-Call Features • 3 Field-programmable paging zone groups (1-3 zones in each) • Programmable All-Call inhibit and privacy beep for talk back zones • Built-in punch block (type 66) speeds installation • One-way and two-way paging (talk back operation requires TBA15 Talk Back amplifier) • Separate volume controls for tones, night ring, and background music • Direct connection to page ports (requires contact closures), loop-start and ground start trunks • Works with self-amplified or central amplifier paging systems • Connection to an analog station line (station port) possible when used with a suitable telephone access module, i.e., Bogen Model TAMB • Optional battery backup • 100W total power handling capacity • Background music input • DIP switches select zone type (one way or talk back), talk battery (24V/48V), and tone options • Built-in night ringer in all zones or group of three user-selected zones • 24V power supply required — Bogen Model PRSLSI power supply recommended • Terminals provided for connection to an additional 48V power supply when 48V talk battery operation required (Bogen PRS48 power supply recommended) • Registered under Part 68 of FCC rules • Includes flanges with keyhole slots for wall-mounting • Shift change or emergency-call (with alert tone) in all zones or group of three user-selected zones* * The shift change/emergency-call feature requires additional customer-supplied equipment — master clock with a contact closure or pre-amplified microphone with built-in or external contact closure. Specifications subject to change without notice. ©2002 Bogen Communications, Inc. Printed in U.S.A. 0510 Part No. 54-7802-04C Technical Specifications Ringer Equivalence: Operating Voltage: Operating Current (Max.): Audio Power Capability: DTMF Tones: Zone Selection: Environmental: Dimensions (Overall): Shipping Weight: Approvals: Architect & Engineer Specifications* 1.2B 24V DC, 350 mA minimum. Model PRSLSI Power Supply Recommended 350 mA 100W (70V AC or 25V AC) Signal Level — 25 dBm;Twist Limit — 10 dB;Tone Duration (min.) — 40 ms; Interdigit Pause — 40 ms Dial Pulse Speed — 8 to 20 ppm; Percent Break — 52% to 64% Operating Temperature — 0° to 125°F; Operating Humidity — 0 to 95% noncondensing 9" W x 7-1/4" H x 1-3/8" D (includes wall-mounting flange) 4 lb. Registered under Part 68 of FCC rules gram (via tone phone) an emergency call zone group The zone paging control module shall be a Bogen Model which shall preempt normal operation, sound the alert ZPM3. It shall be designed for direct connection to loop tone, and open the audio channel for an emergency page start and ground start trunks, and to PBX or KEY paging in up to three user-selected zones. ports that supply a normally-open contact closure and DTMF capability. It shall also connect to analog station ports — (Use for shift change and emergency call feature) using a suitable access module. A choice of tones shall be provided for the shift change signal (or emergency call alert signal). The desired tone The unit shall include flanges with keyhole slots for wallshall be selected via field programming and shall consist mounted installation and a built-in 60-terminal punch block. of either a single-tone burst or dual-tone burst, each Operation shall require a 24V power supply for all applicawith a duration of one second. tions. Contacts shall be provided for connection to an additional 48V power supply when 48V talk battery operation is 6. Built-in DIP switches which shall enable/disable the fieldrequired. programming mode, select the zone type (one-way or The paging control module shall be registered under Part 68 of FCC rules and shall provide at least the following features and functions: 7. 1. Up to three one- or two-way paging zones plus All-Call. 2. Total power handling ability of 100 watts and operation with self-amplified paging systems or central-amplified paging systems. 3. Up to three paging zone groups. Each paging zone group shall be field-programmable and shall contain up to three user-selected zones. two-way), Talk Battery type (24V or 48V), and tone options (pre-announce and confirmation tones). Field-programming from a touch-tone phone. Field-programmable functions shall include assigning individual zones to the paging zone groups, night bell zone group and shift change/emergency call zone group. Field-programming shall also be used to enable/disable a privacy beep over two-way (talk back) zones, select the desired shift change/emergency-call tone, and enable/disable access to All-Call paging. 8. Mute contacts which go to a normally-open state when4. Night ringer circuitry which, when activated by high-voltever the unit is accessing a two-way zone.These contacts age ring signal or contact closure, shall sound a night may be used to operate the talk back muting function on ringer tone in all zones.Alternately, it shall be possible to talk back amplifiers. field-program (via tone phone) a night ringer zone group that shall sound the night ringer tone in up to three user- 9. External contact closure for activating external equipment or for use in ground start trunks, shift change and selected zones. emergency call applications. The contacts shall change 5. Shift change or emergency call signalling as described state when the unit goes off hook. below: 10. Capability of providing uninterrupted background music — (Use for shift change feature) A shift change tone feato all zones not being paged. ture shall be provided.This feature shall be activated by a 11. Battery backup option which will retain user-procustomer-supplied contact closure, which will energize a grammed parameters for up to two hours in the event of customer-supplied external relay, disconnect any current a power failure. The battery backup option shall require page, and sound a user-selected tone in all zones. four (4) AA size nickel cadmium batteries. Alternately, it shall be possible to field-program (via tone phone) a shift change zone group that shall sound the 12. Background music source input jack and screwdriveradjustable volume control. shift change tone in up to three user-selected zones. — (Use for emergency call feature) An emergency call 13. Screwdriver-adjustable volume control of confirmation, pre-announce, error, and shift change/emergency call feature shall be provided. This feature shall be activated tones. by a customer-supplied contact closure (requires a preamplified microphone with built-in contact closure or 14. Screwdriver-adjustable night ringer volume control. microphone and other customer-supplied switch). The emergency call feature shall override the normal paging 15. Wall-mounting design with dimensions of 9" W x 7-1/4" H x 1-3/8" D. Shipping weight shall be 4 lb. features of the module, sound a user-selected alert tone in all zones, and open an audio channel for the emergency page. Alternately, it shall be possible to field-pro* Architect & Engineer Specifications are available on the Bogen website in a Microsoft® Word document to assist you with preparing your bids. 50 Spring Street, Ramsey, New Jersey 07446, U.S.A. 201-934-8500 FAX: 201-934-9832 www.bogen.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:07a96776-3fe8-11da-8b41-000a959b0540 Producer : Acrobat Distiller 6.0 (Windows) Keywords : ZPM3 Zone Paging Module Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2005:10:18 11:01:15-04:00 Create Date : 2005:10:17 13:52:07-04:00 Metadata Date : 2005:10:18 11:01:15-04:00 Document ID : uuid:d9dfd34e-2911-41f6-b63b-c73305a4db3c Format : application/pdf Title : ZPM3 Spec - Zone Paging Module Creator : Joe Sheehan Description : 54-7802-04C Author : Joe Sheehan Subject : 54-7802-04CEXIF Metadata provided by EXIF.tools