Zone Paging Module
Model ZPM3

Description

Field-programming is used to assign individual zones to the
paging zone groups, night ringer zone group, and shift
change/emergency-call zone group*. Field-programming is also
used to enable/disable the privacy beep for two-way zones,
select the shift change/emergency-call tone, and inhibit all-call
The ZPM3 works with self-amplified or central-amplified pagoperation.
ing systems. A background music source can be connected
directly to the ZPM3, or to a separate amplifier that can be A control is included to adjust the volume of the preannounce, confirmation, and shift change/emergency-call
used to supply background music to all unpaged zones.
tones. Separate controls are provided to adjust the night
Built-in DIP switches are used to select the field-programming
ringer tone and background music volume. All volume conmode, enable/disable the pre-announce and confirmation
trols are screwdriver-adjustable.
tones, and set the paging mode (one-way or talk back) of each
zone.
The Bogen ZPM3 is a telephone-compatible zone paging module with all-call and talk back capabilities serving up to three
one- or two-way paging zones.The ZPM3 can also be used in
a paging system independent of a telephone system.

• 3 Zone paging plus All-Call

Features

• 3 Field-programmable paging zone groups
(1-3 zones in each)

• Programmable All-Call inhibit and privacy beep for talk
back zones
• Built-in punch block (type 66) speeds installation

• One-way and two-way paging (talk back operation
requires TBA15 Talk Back amplifier)

• Separate volume controls for tones, night ring, and
background music

• Direct connection to page ports (requires contact
closures), loop-start and ground start trunks

• Works with self-amplified or central amplifier paging
systems

• Connection to an analog station line (station port) possible when used with a suitable telephone access module,
i.e., Bogen Model TAMB

• Optional battery backup

• 100W total power handling capacity
• Background music input
• DIP switches select zone type (one way or talk back), talk
battery (24V/48V), and tone options
• Built-in night ringer in all zones or group of three
user-selected zones

• 24V power supply required — Bogen Model PRSLSI power
supply recommended
• Terminals provided for connection to an additional 48V
power supply when 48V talk battery operation required
(Bogen PRS48 power supply recommended)
• Registered under Part 68 of FCC rules
• Includes flanges with keyhole slots for wall-mounting

• Shift change or emergency-call (with alert tone) in all
zones or group of three user-selected zones*
* The shift change/emergency-call feature requires additional customer-supplied equipment — master clock with a contact
closure or pre-amplified microphone with built-in or external contact closure.

Specifications subject to change without notice.
©2002 Bogen Communications, Inc.
Printed in U.S.A.
0510
Part No. 54-7802-04C

Technical
Specifications

Ringer Equivalence:
Operating Voltage:
Operating Current (Max.):
Audio Power Capability:
DTMF Tones:
Zone Selection:
Environmental:
Dimensions (Overall):
Shipping Weight:
Approvals:

Architect
& Engineer
Specifications*

1.2B
24V DC, 350 mA minimum. Model PRSLSI Power Supply Recommended
350 mA
100W (70V AC or 25V AC)
Signal Level — 25 dBm;Twist Limit — 10 dB;Tone Duration (min.) — 40 ms;
Interdigit Pause — 40 ms
Dial Pulse Speed — 8 to 20 ppm; Percent Break — 52% to 64%
Operating Temperature — 0° to 125°F;
Operating Humidity — 0 to 95% noncondensing
9" W x 7-1/4" H x 1-3/8" D (includes wall-mounting flange)
4 lb.
Registered under Part 68 of FCC rules

gram (via tone phone) an emergency call zone group
The zone paging control module shall be a Bogen Model
which shall preempt normal operation, sound the alert
ZPM3. It shall be designed for direct connection to loop
tone, and open the audio channel for an emergency page
start and ground start trunks, and to PBX or KEY paging
in up to three user-selected zones.
ports that supply a normally-open contact closure and
DTMF capability. It shall also connect to analog station ports — (Use for shift change and emergency call feature)
using a suitable access module.
A choice of tones shall be provided for the shift change
signal (or emergency call alert signal). The desired tone
The unit shall include flanges with keyhole slots for wallshall be selected via field programming and shall consist
mounted installation and a built-in 60-terminal punch block.
of either a single-tone burst or dual-tone burst, each
Operation shall require a 24V power supply for all applicawith a duration of one second.
tions. Contacts shall be provided for connection to an additional 48V power supply when 48V talk battery operation is 6. Built-in DIP switches which shall enable/disable the fieldrequired.
programming mode, select the zone type (one-way or
The paging control module shall be registered under Part 68
of FCC rules and shall provide at least the following features
and functions:
7.
1. Up to three one- or two-way paging zones plus All-Call.
2. Total power handling ability of 100 watts and operation
with self-amplified paging systems or central-amplified
paging systems.
3. Up to three paging zone groups. Each paging zone group
shall be field-programmable and shall contain up to three
user-selected zones.

two-way), Talk Battery type (24V or 48V), and tone
options (pre-announce and confirmation tones).

Field-programming from a touch-tone phone. Field-programmable functions shall include assigning individual
zones to the paging zone groups, night bell zone group
and shift change/emergency call zone group. Field-programming shall also be used to enable/disable a privacy
beep over two-way (talk back) zones, select the desired
shift change/emergency-call tone, and enable/disable
access to All-Call paging.

8. Mute contacts which go to a normally-open state when4. Night ringer circuitry which, when activated by high-voltever the unit is accessing a two-way zone.These contacts
age ring signal or contact closure, shall sound a night
may be used to operate the talk back muting function on
ringer tone in all zones.Alternately, it shall be possible to
talk back amplifiers.
field-program (via tone phone) a night ringer zone group
that shall sound the night ringer tone in up to three user- 9. External contact closure for activating external equipment or for use in ground start trunks, shift change and
selected zones.
emergency call applications. The contacts shall change
5. Shift change or emergency call signalling as described
state when the unit goes off hook.
below:
10. Capability of providing uninterrupted background music
— (Use for shift change feature) A shift change tone feato all zones not being paged.
ture shall be provided.This feature shall be activated by a
11.
Battery
backup option which will retain user-procustomer-supplied contact closure, which will energize a
grammed
parameters for up to two hours in the event of
customer-supplied external relay, disconnect any current
a power failure. The battery backup option shall require
page, and sound a user-selected tone in all zones.
four (4) AA size nickel cadmium batteries.
Alternately, it shall be possible to field-program (via tone
phone) a shift change zone group that shall sound the 12. Background music source input jack and screwdriveradjustable volume control.
shift change tone in up to three user-selected zones.
— (Use for emergency call feature) An emergency call 13. Screwdriver-adjustable volume control of confirmation,
pre-announce, error, and shift change/emergency call
feature shall be provided. This feature shall be activated
tones.
by a customer-supplied contact closure (requires a preamplified microphone with built-in contact closure or 14. Screwdriver-adjustable night ringer volume control.
microphone and other customer-supplied switch). The
emergency call feature shall override the normal paging 15. Wall-mounting design with dimensions of 9" W x 7-1/4"
H x 1-3/8" D. Shipping weight shall be 4 lb.
features of the module, sound a user-selected alert tone
in all zones, and open an audio channel for the emergency page. Alternately, it shall be possible to field-pro* Architect & Engineer Specifications are available on the Bogen
website in a Microsoft® Word document to assist you with preparing your bids.

50 Spring Street, Ramsey, New Jersey 07446, U.S.A.
201-934-8500 FAX: 201-934-9832
www.bogen.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Page Count                      : 2
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:07a96776-3fe8-11da-8b41-000a959b0540
Producer                        : Acrobat Distiller 6.0 (Windows)
Keywords                        : ZPM3 Zone Paging Module
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2005:10:18 11:01:15-04:00
Create Date                     : 2005:10:17 13:52:07-04:00
Metadata Date                   : 2005:10:18 11:01:15-04:00
Document ID                     : uuid:d9dfd34e-2911-41f6-b63b-c73305a4db3c
Format                          : application/pdf
Title                           : ZPM3 Spec -  Zone Paging Module
Creator                         : Joe Sheehan
Description                     : 54-7802-04C
Author                          : Joe Sheehan
Subject                         : 54-7802-04C
EXIF Metadata provided by EXIF.tools

Navigation menu