SMART TOUCH 1.5 Boiler Product Line Brochure
User Manual: SMART TOUCH 1.5
Open the PDF directly: View PDF .
Page Count: 44
Download | |
Open PDF In Browser | View PDF |
Boiler Product Line Brochure Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 Customer Assurance Inquiries (Equipment & Parts Order Inquiry) Please contact 877-554-5544 Technical Service Inquiries (Please have model and serial number available) Please contact 800-722-2101 General Inquiries 615-889-8900/F: 615-547-1000 www.Lochinvar.com Contents From the Solution to the CREST , Lochinvar Boilers are noted for their range of benefits and application flexibility. Collectively, they represent the most complete product line in the industry. From a company with a long history of innovation and a reputation for excellence. TM ® You’ll find there’s a Lochinvar product for any application imaginable – from standard residential units to state-of-the-art commercial products. And with selection, comes opportunity. In fact, the diversity and performance of our product line is surpassed only by its quality–in design, construction, and training. A commitment that is reinforced by the Lochinvar Tech Center, Lochinvar U, a state-of-the-art testing and training facility equipped with the very latest in CAD/CAM technology and a comprehensive R&D lab. Quality, efficiency, features, service, and selection. For more than 90 years, these have been the hallmarks of Lochinvar products. Lochinvar...The innovator in boiler technology. This emblem means a product has a NOx rating which exceeds the requirements of the South Coast Air Quality Management District and Texas Commission of Environmental Quality. This emblem means the Stack Frame is available for use with that product. See page 31 for details. This catalog is designed to provide a convenient, condensed overview of the entire Lochinvar boiler product line. For a complete list of features, specifications and technical data on a particular product, see the full line catalog, your local distributor or contact Lochinvar. Every Lochinvar product is designed and built to meet or exceed the fuel efficiency and safety standards of one or more of these agencies, wherever applicable. CREST® (FBN0751-2001) 1 CREST® (FBN2500-6000) 3 FTXLTM 5 KNIGHT® XL 7 Power-Fin® (PBN2500-5000) 9 Power-Fin® (PBN0502-2001) 11 Copper-Fin II® 13 Copper-Fin® 15 Copper-Fin® Atmospheric 17 KNIGHT® 19 KNIGHT Fire Tube Floor 21 KNIGHT Fire Tube Wall 23 NOBLE™ 25 Cadet® 27 SolutionTM 29 Buffer Tanks/ Hydraulic Separators 31 Squire® Buffer Tank 32 Squire® Indirect 33 Stack Frame 35 Electric Boilers 37 Low Temperature Valve 39 96.2% Thermal Efficiency With the exclusive “Wave” fire-tube design, advancements in Lochinvar combustion technology and the SMART TOUCH™ control, CREST changed how the industry thinks about fire-tube boilers. Now, six new CREST boilers, with 750,000, 1.0 million, 1.25 million, 1.5 million, 1.75 million and 2.0 million Btu/hr inputs, deliver 96.2% thermal efficiency. The Crest Combustion System CREST boilers are equipped with a top-mounted micro-metal fiber burner, engineered specifically for fire-tube technology. The system is designed to ensure smooth, quiet modulating combustion from as low as 4% of maximum firing rate up to 100% as the heating load increases. And in multi-boiler applications, modulation is an essential element in cascade sequencing, which helps ensure maximum efficiency and long-term reliability. Reduce Installation Costs with Variable Flow Technology CREST can operate over a wide range of flow rates with very low pressure drop. This permits installation of a full flow (variable primary) system. Installation is streamlined, without the time and materials cost of primary/secondary piping, and pumps needed to maintain flow in a water-tube boiler. Variable flow also makes CREST more flexible at handling frequent fluctuations in the system flow rate. Smooth-Running, Modulating Combustion With up to 25:1 Modulation Turndown, CREST automatically changes the firing rate as building heat loads vary. An FBN-2001 fires at its maximum 2,000,000 Btu/hr rate when the heat load is highest, and then gradually turns down to as low as 4% (80,000 Btu/hr) as the load decreases. A modulating system runs smoothly and efficiently, without frequent on/off cycling. When the system is zoned, CREST’s high turndown works to match the actual system demand. In return, CREST reduces the customer’s fuel bill and provides better comfort by load-matching the heat loss of the system. Built-in Cascading Sequencer 1 2 3 4 5 6 7 Cascade Redundancy provides peace of mind because it helps ensure that a CREST boiler system will always deliver reliable performance with no downtime. If the lead boiler is turned off for maintenance, Cascade Redundancy automatically shifts the lead role to the second sequenced boiler. Up to eight CREST boilers can be sequenced using a 2-wire daisy chain connection. Cascade sequencing can be programmed for 8 Lead-Lag or Efficiency Optimized operation. With Lead-Lag operation, one lead boiler modulates to capacity on demand. As the load increases, the system then cascades to additional lag boilers in sequence. The first-on role shifts daily, distributing equal runtimes to each unit. In an Efficiency Optimized system, all boilers fire and modulate simultaneously at the same Btu/hr input rates, maximizing thermal efficiency. Unequaled Control and Monitoring Crest features the next generation of Lochinvar’s all-in-one SMART TOUCH operating control with the integration of the CON·X·US® advanced technology. SMART TOUCH with CON·X·US provides outstanding functionality and can be integrated directly into building automation systems via Modbus or BACnet MSTP as standard equipment. And now, the CON·X·US mobile communication platform allows SMART TOUCH to go where no other boiler has gone before. CON·X·US provides the ability to monitor and manage multiple Crest boiler plants without ever stepping into mechanical rooms. 1 CREST® Boiler Dimensions & Specifications LOW VOLTAGE HIGH VOLTAGE RELIEF VALVE HIGH VOLTAGE H LOW VOLTAGE VENT WATER OUTLET 78" GAS C B AIR L F DRAIN D CONDENSATE DRAIN WATER INLET DRAIN E K 11 3/8" 11 1/4" 12 1/2" G A J SIDE Net AHRI AHRI Thermal Output Rating Min Max Efficiency MBH MBH Turndown BACK Input MBH Model Number A B C D E TOP F G H J K L Water Gas Inlet/ Air Vent Conn. Outlet Intake Size Oper. Weight Ship. Wt. (lbs) FBN0751 50 750 96.2% 722 627 15:1 30” 49-1/2” 51” 13” 8-3/4” 23-3/4” 26-3/4” 7-3/8” 57-5/8” 11-7/8” 66-1/8” 1-1/4” 3” 6” 6” 1,768 1,560 FBN1001 50 1,000 96.2% 962 837 20:1 30” 49-1/2” 51” 13” 8-3/4” 23-1/8” 26-3/4” 6-1/2” 57-5/8” 11-7/8” 66-1/8” 1-1/4” 3” 6” 6” 1,838 1,596 FBN1251 63 1,250 96.2% 1,203 1,046 20:1 30” 49-1/2” 51-3/8” 13” 8-3/4” 21-5/8” 26-3/4” 6-1/2” 57-3/4” 11-7/8” 66-1/8” 1-1/4” 3” 6” 8” 1,975 1,648 FBN1501 60 1,500 96.2% 1,443 1,255 25:1 30” 59-1/4” 62-3/8” 15-7/8” 9” 27-7/8” 26-7/8” 5-1/8” 68” 12-3/8” 65-3/8” 1-1/2” 4” 8” 8” 2,307 1,961 FBN1751 70 1,750 96.2% 1,684 1,464 25:1 30” 58-3/4” 61-1/2” 15-7/8” 9” 27-1/8” 27” 5-1/8” 68” 12-3/8” 65-3/8” 1-1/2” 4” 8” 8” 2,458 2,017 FBN2001 80 1,999 96.2% 1,924 1,673 25:1 30” 58-3/4” 61-1/2” 15-7/8” 9” 26-3/4” 27” 5-1/8” 68” 12-3/8” 65-3/8” 1-1/2” 4” 8” 8” 2,570 2,087 NOTES: Change "N" to "L" for LP gas models. Indoor installation only. *Information subject to change without notice Smart Touch™ Features CON·X·US Remote Connect SMART TOUCH Touchscreen Operating Control Full-Color 8" Touchscreen LCD Display Built-in Cascading Sequencer for up to 8 Boilers with Built-in Redundancy > Cascade Multiple Sized Boilers > Lead/Lag Cascade > Efficiency Optimized Cascade Front-End Loading Capability with Copper-Fin II® and Power-Fin® Boilers Building Management System Integration with 0-10 VDC Input BACnet MSTP and Modbus Communications Outdoor Reset Control with Outdoor Air Sensor Password Security Domestic Hot Water Prioritization > DHW tank piped with priority in the boiler loop > DHW tank piped as a zone in the system with the > pumps controlled by the Smart System > DHW Modulation Limiting > Separately Adjustable SH/DHW Switching Times Low Water Flow Safety Control & Indication Inlet & Outlet Temperature Readout Freeze Protection Service Reminder Time Clock Data Logging > Hours Running, Space Heating > Hours Running, Domestic Hot Water > Hours Running, Modulation Rate > Ignition Attempts > Last 10 Lockouts Programmable System Efficiency Optimizers > Night Setback > Anti-Cycling > Outdoor Air Reset Curve > Ramp Delay > Boost Temperature & Time > Modulation Factor Control ® Three Pump Control > System Pump > Boiler Pump > Domestic Hot Water Pump High-Voltage Terminal Strip > 120 VAC / 60 Hertz / 1 Phase Power Supply > System Pump, Boiler Pump and DHW Pump Power Low-Voltage Terminal Strip > 24 VAC Auxiliary Device Relay > Auxiliary Proving Switch Contacts > Alarm on Any Failure Contacts > Runtime Contacts > DHW Thermostat Contacts > Unit Enable/Disable Contacts > System Sensor Contacts > DHW Tank Sensor Contacts > Outdoor Air Sensor Contacts > Cascade Contacts > 0-10 VDC BMS External Control Contact > 0-10 VDC Variable Speed Boiler Pump Control Contact Optional Equipment Wireless Outdoor Temperature Sensor Alarm Bell BMS Gateway - BACnet IP or LonWorks Condensate Neutralization Kit Common Vent Kits Electrical Options (Shipped Loose): > 208V/3Ø/60Hz > 480V/3Ø/60Hz > 600V/3Ø/60Hz Motorized Isolation Valve Variable Speed Boiler Pump Gas Regulator Codes & Registrations Standard Features 96.2% Thermal Efficiency (AHRI) Up to 99% Thermal Efficiency in Low-Temp. Applications Modulating Burner with up to 25:1 Turndown Direct-Spark Ignition Low-NOx Operation Sealed Combustion Air Inlet Filter w/Replacement Reminder Low Gas Pressure Operation Vertical and Horizontal Direct Venting > Direct Vent up to 100 Feet > PVC, CPVC, Polypropylene or AL29-4C ASME “H” Stamped Heat Exchanger 316L Stainless Steel Fire Tubes 160 psi Working Pressure On/Off Switch Adjustable High Limit with Manual Reset Low Water Cutoff with Manual Reset & Test High & Low Gas Pressure Switches w/Manual Reset Low Air Pressure Switches Condensate Trap w/Blocked Drain Switch Drain Valve System Sensor Outdoor Air Sensor Inlet & Outlet Temperature Sensors High-Voltage Terminal Strip Low-Voltage Terminal Strip Downstream Gas Test Cocks 50 psi ASME Relief Valve Temperature & Pressure Gauge Zero Clearances to Combustible Materials 10-Year Limited Warranty (See Warranty for Details) 1-Year Warranty on Parts (See Warranty for Details) ANSI Z21.13/CSA Certified ASME Certified, “H” Stamp / National Board California Code Compliant CSD1 / Factory Mutual / GE Gap Compliant AHRI Certified Canadian Registration Number (CRN) 2 Up to 93% Thermal Efficiency Lochinvar® has taken the fire-tube concept in an innovative direction with the CREST® modulating-condensing boiler. With sizes that range from 2.5 to 5.0 million Btu/ hr, you have the opportunity to utilize Lochinvar leading-edge technology in your largest applications. With thermal efficiencies up to 99% in low water temperature applications, CREST is positioned to provide exceptional energy-saving performance. The advanced CREST introduces a combustion system with a unique burner design with up to 20:1 turndown. The burner fires into an array of 316L stainless steel fire-tubes that transfer the heat to the surrounding water with exceptionally high efficiency. CREST communicates seamlessly and in real time with building management systems by utilizing an on-board Modbus protocol and BACnet MSTP. The SMART TOUCH control with CON·X·US® has a built-in cascading component that communicates with up to eight units, providing total command without an external control or complex and expensive control logic programming by the BMS integrator. 93% With the added feature of CON·X·US remote connectivity, the CREST boiler can be monitored from anywhere even if your building does not have a building management system. Innovative fire-tube boiler technology integrated with our SMART TOUCH™ operating control makes CREST a genuine game-changer among commercial boilers. Advanced Negative Regulation Technology CREST safely and reliably operates with supply gas pressure as low as 4 inches water column. Because Negative Regulation (Neg/Reg) technology draws fuel gas into a pre-mix combustion system instead of relying on utility pressure through the gas valve, operation is steady in low gas pressure systems or when peak demands occur on supply lines. Plus, Neg/Reg automatic fan speed control fine-tunes the correct fuel/air ratio entering the burner, providing even, consistent combustion for a cleaner burning flame achieving high combustion efficiency. Fully Modulating up to 20:1 Turndown 20:1 turndown means the burner can fire at a rate as low as 5% of its maximum input. For example, a 2.5 million Btu/hr CREST unit can modulate from 125,000 up to 2,500,000 Btu/hr depending on demand. High turndown greatly reduces “short cycling” when demand is low. All boiler systems are designed to provide enough heat to maintain a facility’s heat loss on the coldest days. When the system is zoned, the CREST’s high turndown works to match the actual system demand and, in return, reduces the customer’s fuel bill and provides better comfort by load matching the heat loss of the system. Greater seasonal efficiencies will be realized due to the extremely large turndown offered by CREST. As Low As 25 GPM* to Full 350 GPM Flow Rates CREST allows system designers tremendous flexibility to vary the flow rate through the boiler. It can service systems that operate with widely fluctuating flow rates depending on demand. CREST can be installed with primary/secondary piping or in a full-flow arrangement. Typical design techniques include full-flow systems or variable flow systems using variable frequency drives on the heating water pumps. In either case, CREST excels in these applications and allows the flow through the boiler to vary based on system demand. * 25 GPM min. flow on FB2500 model, 50 GPM on FB5000 model. Built-in Cascading Sequencer Sequences up to an 8-boiler system using simple 2-wire daisy chain connection, eliminating cost and uncertainty of a separate “third party” sequencer. On demand, one boiler functions as the leader and modulates to capacity. Increasing load then “cascades” to additional “lag” boilers in sequence as needed. Lead-lag rotation shifts “first on” boiler role every 24 hours, distributing equal leadlag runtimes to each unit. Boiler Control from Anywhere Crest features the next generation of Lochinvar’s all-in-one SMART TOUCH operating control with the integration of the CON·X·US advanced technology. SMART TOUCH with CON·X·US provides outstanding functionality, and can be integrated directly into building automation systems via Modbus and BACnet MSTP as standard equipment. ® REMOTE CONNECT And now, the CON·X·US mobile communication platform allows the SMART TOUCH to go where no other boiler has gone before. CON·X·US provides the ability to monitor and manage multiple Crest boiler plants without ever stepping into the mechanical rooms. 3 CREST® Boiler Dimensions & Specifications H LOW VOLTAGE HIGH VOLTAGE RELIEF VALVE HIGH VOLTAGE LOW VOLTAGE VENT WATER OUTLET B 80" C AIR L GAS WATER INLET D 14-7/8" 10 -1/4" 8" J E 11" G CONDENSATE DRAIN K SIDE Crest Heating Boiler F DRAIN DRAIN BACK A TOP Dimensions and Specifications Model Input Input AHRI NET AHRI Gas Air Vent Oper. Ship Number MBH MBH Thermal Output Rating B C D E F G H J K Conn. Inlet Size Wt. (lbs) Wt. (lbs) Min. Max. Efficiency MBH MBH Turndown A 34-1/4" 76-3/8" 70-1/4" 17-3/4" 26-1/8" 9-3/4" 27-3/8" 11-3/8" 78" 83" 2" 8” 9” 3,652 2,560 FBN2500 125 2,500 92.0% 2,300 2,000 20:1 40-1/2" 83-5/8" 76-3/8" 17-3/8" 31-3/8" 9-7/8" 34-3/4" 11-1/2" 82-1/8" 87-1/8" 2" 10” 10” 4,126 2,920 FBN3000 150 3,000 92.0% 2,760 2,400 20:1 40-1/2" 83-1/4" 75-5/8" 17-1/4" 31-3/8" 9-7/8" 34-3/4" 12-7/8" 81-1/8" 86-1/8" 2" 10” 10” 4,744 3,225 FBN3500 200 3,500 92.0% 3,220 2,800 18:1* 53-1/2" 109" 100-3/4" 31-1/4" 40-3/4" 14-1/2" 45-3/4" 12-3/4" 104-1/2" 108-1/4" 2-1/2" 12” 12” 6,900 4,750 FBN4000 335 4,000 93.0% 3,720 3,235 12:1 53-1/2" 107" 100-3/4" 28" 40-3/4" 11" 45-1/2" 12-3/4" 104" 108-1/4" 2-1/2" 14” 14” 8,000 5,550 FBN5000 500 5,000 93.0% 4,650 4,043 10:1 53-1/2” 107 100-3/4” 28” 40-3/4” 11 45-1/2” 9” 104” 108-1/4” 2-1/2” 14” 14” 8,100 5,650 FBN6000 600 6,000 92.0% 5,520 4,799 10:1 Notes: Indoor installation only. All information subject to change. Change "N" to "L" for LP gas models. For Low NOx on FB2500 - FB5000 models, consult factory. *Turndown rate reduced on LP gas model. Smart Touch™ Features CON·X·US Remote Connect SMART TOUCH Touchscreen Operating Control Full-Color 8” Touchscreen LCD Display Built-in Cascading Sequencer for up to 8 Boilers > Cascade Multiple Sized Boilers > Lead/Lag Cascade > Efficiency Optimized Cascade Front-End Loading Capability with Copper-Fin II and Power-fin Boilers Building Management System Integration with 0-10 VDC Input BACnet MSTP and Modbus Communications Outdoor Reset Control with Outdoor Air Sensor Password Security Domestic Hot Water Prioritization > DHW tank piped with priority in the boiler loop > DHW tank piped as a zone in the system with the pumps controlled by the Smart System > DHW Modulation Limiting > Separately Adjustable SH/DHW Switching Times > Low Water Flow Safety Control & Indication > Inlet & Outlet Temperature Readout > Freeze Protection > Service Reminder > Time Clock Data Logging > Hours Running, Space Heating > Hours Running, Domestic Hot Water > Hours Running, Modulation Rate > Ignition Attempts > Last 10 Lockouts Programmable System Efficiency Optimizers > Night Setback > Anti-Cycling > Outdoor Air Reset Curve > Ramp Delay > Boost Temperature & Time Three Pump Control > System Pump > Boiler Pump > Domestic Hot Water Pump High-Voltage Terminal Strip > 120 VAC / 60 Hertz / 1 Phase Power Supply (FB25003500) > 208 VAC / 60 Hertz / 3 Phase Power Supply (FB40005000) > System Pump, Boiler Pump and DHW Pump Power Low-Voltage Terminal Strip > 24 VAC Auxiliary Device Relay > Auxiliary Proving Switch Contacts > Alarm on Any Failure Contacts > Runtime Contacts > DHW Thermostat Contacts > Unit Enable/Disable Contacts > System Sensor Contacts > DHW Tank Sensor Contacts > Outdoor Air Sensor Contacts > Cascade Contacts > 0-10 VDC BMS External Control Contact Standard Features Up to 93% Thermal Efficiency (AHRI) Up to 99% Thermal Efficiency in Low Temperature Applications Modulating Burner with up to 20:1 Turndown Direct-Spark Ignition Sealed Combustion Low Gas Pressure Operation Vertical or Horizontal Venting Category IV Venting up to 100 Feet ASME “H” Stamped Heat Exchanger 316L Stainless Steel Fire Tubes 160 psi Working Pressure On/Off Switch Adjustable High Limit with Manual Reset Low Water Cutoff with Manual Reset & Test High & Low Gas Pressure Switches w/Manual Reset Low Air Pressure Switches Condensate Trap w/ Blocked Drain Switch Drain Valve System Sensor Outdoor Air Sensor Inlet & Outlet Temperature Sensors High Voltage Terminal Strip Low Voltage Terminal Strip Downstream Gas Test Cocks 50 psi ASME Relief Valve Temperature & Pressure Gauge Zero Clearances to Combustible Materials 10-Year Limited Warranty (See Warranty for Details) 1-Year Warranty on Parts (See Warranty for Details) Optional Equipment Alarm Bell BMS Gateway - BACnet IP or LonWorks Condensate Neutralization Kit Common Vent Damper Dual Fuel Gas Train Electrical Options (Shipped Loose): > 208V/3Ø/60Hz (Models FB2500-3500 only) > 480V/3Ø/60Hz > 600V/3Ø/60Hz Motorized Two Way Valve Variable Speed Boiler Pump Gas Regulator Inline Air Filter Codes & Registrations ANSI Z21.13/CSA Certified ASME certified, “H” Stamp / National Board California Code Compliant CSD1 / Factory Mutual / GE Gap Compliant Canadian Registration Number (CRN) AHRI Certified U.S. Patent # 8,286,594 4 The New 98% Standard Lochinvar re-defined the fire-tube boiler category with its KNIGHT® Wall-Mount and CREST® lines. For residential and light commercial applications, the FTXL™ adds models from 399,999 to 850,000 Btu/hr, and takes Lochinvar’s fire-tube technology to the next level. FTXL offers best-in-class AHRI Thermal Efficiency and footprints, plus remote connectivity that puts the SMART SYSTEM™ control at your fingertips, anywhere! Reduce Installation Cost with Variable Flow Technology FTXL can operate over a wide range of flow rates with very low pressure drop. This permits installation of a “full flow” (variable primary) system eliminating the time and materials cost of primary/secondary piping, and pumps needed to maintain flow in a water-tube boiler. Variable flow also makes FTXL more flexible at handling frequent fluctuations in the system flow rate. Smooth-Running, Modulating Combustion FTXL boilers have a top-mounted, micrometal fiber burner, with a blower/ gas valve assembly that drives heat energy downward, through stainless steel fire tubes, with exhaust venting through the bottom of the unit. With up to 10:1 modulation turndown, the burner automatically changes its firing rate as building heat loads vary. An FTX500 fires at its maximum 500,000 Btu/hr rate when heat load is highest, then gradually “turns down” to as low as 10% (50,000 Btu/hr) as load decreases. A modulating system runs smoothly and efficiently, without frequent on/off cycling. Minimum Supply Pressure, Installer-Friendly FTXL operates with supply gas pressure as low as 4 inches water column. Negative Regulation draws gas into a pre-mix combustion system, instead of relying on utility pressure through the gas valve. The result is steady operation in low gas pressure systems or when peak demand occurs on gas supply. Automatic fan speed control fine-tunes the correct fuel/air ratio entering the burner, providing superior combustion throughout the entire operating range. Cascade Sequencing Up to eight FTXL boilers can be sequenced using a 2-wire daisy chain connection. Cascade sequencing can be programmed for “Lead-Lag” or “Efficiency Optimized” operation. With LeadLag operation, one lead boiler modulates to capacity on demand. As load increases, the system then cascades to additional lag boilers in sequence. The first-on role shifts daily, distributing equal runtimes to each unit. In an Efficiency Optimized system, all boilers fire and modulate simultaneously at the same BTU/hr input rates, maximizing thermal efficiency. 5 Boiler Plant Control, from Anywhere FTXL features the next generation of Lochinvar’s all-in-one SMART SYSTEM operating control with a re-designed multi-color LCD interface. SMART SYSTEM provides outstanding functionality, and can be integrated directly into a building automation system via ModBus and other communications protocols. And now, the CON·X·US mobile communication platform allows SMART SYSTEM to go where no other boiler has gone before.† CON·X·US provides the ability ® to monitor and manage multiple REMOTE CONNECT FTXL boiler plants without ever stepping into the mechanical room. CON·X·US will send alerts via text or e-mail notifying of changes in system status, and anytime, from anywhere, a user can check system status and re-program any boiler function. Once downloaded, the free CON·X·US mobile application allows for remote access to all SMART SYSTEM functions using any Internet-capable device. †CON·X·US control board sold separately. FTXL™ Boiler Dimensions & Specifications E Air Inlet D Electrical Connections C 2-1/2" A Gas Connection F 53-1/2" G 65-1/2" B Water Outlet 40" Water Inlet Flue Connection H 26-1/4" Model Number FTX400(N,L) FTX500(N,L) FTX600(N,L) FTX725(N,L) FTX850(N,L) 26-1/4" 9-3/4" 2-1/2" Condensate Connection Input AHRI NET AHRI HEX Min Max Thermal Output Rating Turn Flow (GPM) Water MBH MBH Efficiency MBH MBH down Min Max Volume 40.0 399.9 98.0% 392 341 10:1 10 105 13 50.0 500.0 97.7% 489 425 10:1 15 105 12 85.0 600.0 97.5% 585 509 7:1 15 105 12 103.5 725.0 97.2% 705 613 7:1 20 150 17 121.5 850.0 97.0% 825 717 7:1 25 150 16 A 22-1/2" Water Vent Air A B C D E F G H Conn. Size Intake 30-1/2" 27-1/2" 10-1/4" 17" 23-1/4" 46-1/4" 39-1/2" 10-3/4” 2" 4” 4” 30-1/2" 27-1/2" 10-1/4” 17" 23-1/4" 46-1/4" 39-1/2” 10-3/4” 2" 4” 4” 30-1/2" 27-1/2" 10-1/4” 17" 23-1/4" 46-1/4" 39-1/2” 10-3/4” 2" 4” 4” 33” 28-1/2" 10-1/2” 17-1/2" 23-1/2" 48-1/2" 41-1/4” 11" 2-1/2" 6” 4” 33" 28-1/2" 10-1/2” 17-1/2" 23-1/2" 48-1/2" 41-1/4" 11" 2-1/2" 6” 4” Gas Ship Conn. Wt. (lbs) 1” 435 1” 460 1” 470 1” 510 1” 535 *Information subject to change without notice Dimensions are in inches. Select “N” or “L” for Natural or LP gas Smart System Features > Smart System Digital Operating Control Multi-Color Graphic LCD Display w/Navigation Dial > Loch-N-Load USB Thumb Drive Port for Easy Programming > Cascading Sequencer with Built-in Redundancy Selectable Cascade Type: Lead Lag/Efficiency Optimization Multiple Size Boilers Front-End Loading > 3 Reset Temperatures Inputs w/Independent Outdoor Reset Curves for Each Outdoor Sensor > Four-Pump Control System Pump with Parameter for Continuous Operation Boiler Pump with Variable-Speed Control Domestic Hot Water Boiler Pump Domestic Hot Water Recirculation Pump Control with Sensor > Building Management System Integration 0-10 VDC Input to Control Modulation or Setpoint 0-10 VDC Input from Variable-Speed System Pump 0-10 VDC Modulation Rate Output Signal 0-10 VDC Enable/Disable Signal > Programmable System Efficiency Optimizers Space Heating Night Setback DHW Night Setback Anti-Cycling Ramp Delay Boost Time and Temperature > High-Voltage Terminal Strip 120 VAC/60 Hertz/1 Phase Pump Contacts for 3 Pumps > Low-Voltage Terminal Strip Building Recirculation Pump Start/Stop Proving Switch Contacts Flow Switch Contacts Alarm Contacts Runtime Contacts 3 Space Heat Thermostat Contacts Tank Thermostat Contacts System Sensor Contacts Tank Sensor Contacts Cascade Contacts 0-10 VDC BMS Contacts 0-10 VDC Boiler Rate Output Contacts 0-10 VDC Boiler Pump Speed Contacts 0-10 VDC System Pump Speed Contacts ModBus Contacts > Time Clock > Data Logging Ignition Attempts Last 10 Lockouts Space Heat Run Hours Domestic Hot Water Run Hours Standard Features > 97%-98% Thermal Efficiency > Modulating Burner with up to 10:1 Turndown Direct Spark Ignition Low NOx Operation Sealed Combustion Low Gas Pressure Operation > Stainless Steel Fire-Tube Heat Exchanger ASME-Certified, “H” Stamped 160 psi Working Pressure 50 psi Relief Valve Combustion Analyzer Test Port Fully Welded Design > Vertical and Horizontal Direct Vent Direct Vent up to 100 feet PVC, CPVC, Polypropylene or AL29-4C Factory Supplied Sidewall Vent Termination > Smart System Control > Other Features On/Off Switch Adjustable High Limit with Manual Reset Automatic Reset High Limit Manual Reset Low Water Cutoff Flue Temperature Sensor Low Air Pressure Switch Temperature and Pressure Gauge Condensate Trap Zero Service Clearances 10-Year Limited Warranty (See Warranty) Custom Maintenance Reminder with Contact Info Password Security Customizable Freeze Protection Parameters Optional Equipment CON·X·US Remote Connect Motorized Isolation Valve Wireless Outdoor Sensor Multi-Temperature Loop Control Variable-Speed Boiler Circulator Constant-Speed Boiler Circulator ModBus Communication Alarm Bell Condensate Neutralization Kit Concentric Vent Kit (FTX400-FTX600) BMS Gateway to BACnet or LonWorks High and Low Gas Pressure Switches w/Manual Reset(FTX500-FTX850) > Firing Controls M9-Standard Construction M13-CSD-1/FM/GE Gap (FTX500-FTX850) 6 The Smartest Choice for Condensing Boiler Performance The KNIGHT® XL, engineered with Lochinvar’s exclusive SMART SYSTEM™ control and an array of other innovative features, places it far ahead of any commercial heating boiler in its class. It promises and delivers ultimate ease of installation and maintenance. With up to 94% thermal efficiency, low-NOx emissions and a fully modulating burner, it is the best ”green choice” for today’s environmentally focused market. Five modulating/condensing stainless steel KNIGHT XL boilers are available with 399,999–800,000 Btu/hr inputs and remarkably small space-saving footprints. All are equipped for direct-vent installation with air intake and exhaust runs up to 100 feet using PVC, CPVC, Polypropylene or AL29-4C vent materials. This range of choices is ideal for light-duty applications such as small hotels, schools and office buildings. For higherdemand applications, up to eight KNIGHT XL units can be installed utilizing the built-in cascading sequencer to deliver up to 6.4 million Btu/hr heating capacity. Control SMART SYSTEM provides unequalled control and monitoring functions that are easy to understand and use. • Multi-Color Graphic LCD Display • Navigation Dial • USB Port • Modbus Capability (Optional) • DHW Modulation Limiting • DHW Night Setback • Controls up to three different setpoint temperatures • 0-10V Boiler Rate Output • 0-10V Signal to control variable speed boiler pump • 0-10V System Pump Signal Input* • Heat Demand from 0-10V Input • Installer to Program Name and Number into the Boiler • Freeze Protection Parameters Installer Adjustable • Separately adjustable SH/DHW Switching times* • Installer access to BMS and ramp delay settings *Exclusive to Lochinvar Smart System Advanced Negative Regulation Technology KNIGHT XL safely and reliably operates with supply gas pressure as low as 4 inches water column. Negative Regulation (Neg/Reg) technology automatically adjusts fan speed that ensures the correct volume and mix of fuel and air throughout the firing range. Two-in-One Stainless Steel Heat Exchanger A primary heat exchanger combined with a secondary heat exchanger captures flue gas heat and condenses to utilize available latent energy. The stainless steel, pH-tolerant design features a weld-sealed assembly with no O-rings or gaskets and does not require special glycol. ASME Section IV approved and stamped. Fully Modulating Burner The SMART SYSTEM allows fully modulating combustion with 5:1 turndown. The burner can fire as low as 20% of maximum input and modulates the firing rate up to 100% as demand increases. The burner is a single stainless steel assembly covered with woven steel mesh and fires in a 360° pattern along the entire length of the primary heat exchanger. This allows the compact KNIGHT XL to exceed the capacity of units with larger multiple burners. Direct Venting up to 100 Feet KNIGHT XL offers 7 venting options and tremendous flexibility for placement of units within the building, because it permits direct-vent air intake and exhaust runs up to 100 equivalent feet using either PVC, CPVC, Polypropylene or AL29-4C stainless steel vent pipe. A sidewall vent termination kit is shipped standard with every KNIGHT XL boiler. 7 KNIGHT XL® Boiler Dimensions & Specifications LOW VOLTAGE ELECTRICAL CONNECTIONS K HIGH VOLTAGE ELECTRICAL CONNECTIONS GAS AIR INLET J INLET 39-1/2" FLUE I HEAT EXCHANGER DRAIN 3/4" NPT OUTLET A 38-3/4" CONDENSATE DRAIN H FLUE 18-3/4" 13-3/4" 3-1/2" 8" G B D BACK F 1/4" - 1-1/4" ADJUSTABLE E C FRONT LEFT SIDE Knight® XL Heating Boiler Input AHRI Model Min Max Thermal Output Number MBH MBH Efficiency MBH KBN400 80 399 94.0% 376 KBN501 100 500 94.0% 470 KBN601 120 600 94.0% 564 KBN701 140 700 94.0% 658 KBN801 160 800 94.0% 752 9" Net AHRI Rating MBH 327 409 490 572 654 Dimensions and Specifications A B C D E F G H I J K Gas Water Air Vent Ship Conn. Conn. Inlet Size Wt. (lbs) 42-1/2” 15-1/2” 27-3/4” 3-3/4” 20-3/4” 21” 14” 34” 34” 2” 18-3/4” 1” 1-1/2” 4” 4” 280 42-1/2” 15-1/2” 31-1/2” 3-3/4” 25-1/2” 21” 14” 32-1/2” 36” 2” 18” 1” 1-1/2” 4” 4” 310 42-1/2” 15-1/2” 36-1/4” 3-3/4” 25” 21” 14” 36” 32-3/4” 5-1/2” 19-1/2” 1” 2” 4” 4” 340 42-1/2” 15-1/2” 40-1/4” 3-3/4” 29” 23” 17” 36” 32-3/4” 3-1/4” 23-1/2” 1” 2” 4” 6” 370 42-1/2” 15-1/2” 45-1/4” 3-3/4” 33-1/4” 23” 17” 36” 32-3/4” 3-1/4” 27-3/4” 1” 2” 4” 6” 405 Notes: Indoor installation only. All information subject to change. Change “N” to “L” for LP gas models. Standard Features Built in Cascading Sequencer for up to 8 Boilers Multiple Size Boiler Cascade 94% AHRI Certified Thermal Efficiency Lead Lag Modulating Burner with 5:1 Turndown Efficiency Optimization > Direct-Spark Ignition Front End Loading with Copper-Fin II® > Low NOx Operation Outdoor Reset Control with Outdoor Air Sensor > Sealed Combustion Programmable System Efficiency Optimizers > Low Gas Pressure Operation > Night Setback ASME Stainless Steel Heat Exchanger > DHW Night Setback > Anti-Cycling > ASME Certified, ”H” Stamped > Outdoor Air Reset Curve Gasketless Heat Exchanger > Ramp Delay > 160 psi Working Pressure > Boost Temperature & Time > 50 psi ASME Relief Valve Three Pump Control > Highly efficient, condensing design > System Pump With Parameter for Continuous Operation Vertical & Horizontal Direct-Vent > Boiler Pump With Variable Speed Pump Control > Domestic Hot Water Pump > Category IV venting up to 100 feet Domestic Hot Water Prioritization > PVC, CPVC, Polypropylene or AL29-4C > DHW tank piped with priority in the boiler loop Venting up to 100 Feet > DHW tank piped as a zone in the system with > Factory Supplied Sidewall Vent Termination the pumps controlled by the Smart System Smart SystemTM Control > DHW Modulation Limiting Other Features > Separately Adjustable SH/DHW Switching Times* On/Off Switch Building Management System Integration Adjustable High Limit w/ Manual Reset > 0-10 VDC Input to Control Modulation or Set Point > 0-10 VDC Input Signal from Variable Speed System Pump* Automatic Reset High Limit > 0-10 VDC Modulation Rate Output Flow Switch > 0-10 VDC Input to Enable/Disable call for heat Flue Temperature Sensor > Access to BMS Settings through Display Low Air Pressure Switch High Voltage Terminal Strip Temperature & Pressure Gauge > 120 VAC / 60 Hertz / 1 Phase Power Supply Adjustable Leveling Legs > Three sets of Pump Contacts with Pump Relays Condensate Trap Low Voltage Terminal Strip Zero Clearances to Combustible Material 24 VAC Device Relay 10 Year Limited Warranty (See Warranty) Proving Switch Contacts Flow Switch Contacts Alarm on Any Failure Contacts Smart System Features Runtime Contacts SMART SYSTEM Digital Operating Control DHW Thermostat Contacts > Multi-Colored Graphic LCD Display w/ 3 Space Heat Thermostat Contacts Navigation Dial System Sensor Contacts > Three Reset Temperature Inputs with curves for three set point temperature inputs DHW Tank Sensor Contacts Outdoor Air Sensor Contacts Cascade Contacts 0-10 VDC BMS External Control Contact 0-10 VDC Boiler Rate Output Contacts 0-10 VDC Variable Speed System Pump Signal Input 0-10 VDC Signal to Control Variable Speed Boiler Pump Modbus Contacts Time Clock Data Logging > Hours Running, Space Heating > Hours Running, Domestic Hot Water > Ignition Attempts > Last 10 Lockouts Other Features Low Water Flow Safety Control & Indication Password Security Inlet & Outlet Temperature Readout Customizable Freeze Protection Parameters Custom Maintenance Reminder with Contractor Info *Exclusive feature, available only from Lochinvar Optional Equipment CON·X·US Remote Connect Alarm Bell Condensate Neutralization Kit Concentric Vent Kit (KB400-KB601) BMS Gateway - BACnet or LonWorks High & Low Gas Pressure Switches w/ Manual Reset (KB501-KB801) Modbus Communication Multi Temperature Loop Control Low Water Cutoff w/Manual Reset & Test Boiler Circulation Pump Stainless Steel Vent Kits (KB701-KB801) Stack Frame Variable Speed Boiler Pump Wireless Outdoor Sensor Firing Control Systems M9 Standard Construction M7 California Code M13 CSD1 / FM / GE Gap (KB501-KB801) Registered under U.S. Patent # 7,824,178 8 2,500,000 to 5,000,000 Btu/hr models A Legendary Boiler Has More Than Doubled Its Output In 1986, Power-Fin® redefined the industry with its space-saving design, groundbreaking efficiency and venting flexibility. Now we’re raising the bar again by more than doubling its maximum input Starting with the introduction of Power-Fin product capacity from 2 to 5 line in 1986, we were able to provide something million BTU/hr. The that other companies weren’t focused on, efficiency Power-Fin’s new heat and footprint. Now, 30 years later, we are proud to continue that tradition and provide some of the most exchanger features efficient products on the market. an innovative double row of swept fins that delivers 2.5 times the output of the original model. The PowerFin continues to offer a space-saving footprint and all models will pass through a 36˝ wide door.* Enhanced Operating Control The Power-Fin now offers the industry-best Smart Touch™ 8˝ LCD full color touchscreen with easy-to-understand infographics. It is equipped with CON·X·US® connectivity that lets you remotely monitor and optimize the performance of the entire boiler plant. Burner Modulation Boosts Efficiency and Lowers Costs With thermal efficiencies up to 87%, Power-Fin boilers feature a 5:1 turndown ratio that will precisely match the firing rates to heating load requirements—at any point from 20% to full firing rate. This results in less equipment cycling for greater efficiency and cost savings. Ready for Outdoor Installation In warm-weather sites where the mechanical room is overcrowded, the Power-Fin can be easily installed either outdoors or on a rooftop. Its optional hood and screen protector make outdoor installation fast and trouble free. Venting Solutions The Power-Fin offers seven venting options for ease of installation and venting flexibility to meet the most challenging installation requirements. The Power-Fin permits air intake and exhaust lengths up to 100 ft, allowing terminations to be horizontal through a sidewall or vertical through a roof. If floor space is limited, the Power-Fin can be installed outdoors with the addition of the outdoor kit. 9 Power-Fin ® Boiler Dimensions & Specifications J K M B G N C P Power-Fin Boiler L Dimensions and Specifications Model Gas Air Number H J K L M N P Q Conn. Inlet PBN2500 9” 20-1/4” 37” 8-3/4” 23” 21-1/4” 12” N/A 2” 9” PBN3000 9” 20-1/4” 43” 8-3/4” 23” 21-1/4” 12” N/A 2” 9” PBN3500 9” 20-1/4” 48-1/2” 9” 23” 21-1/4” 12” N/A 2” 10” PBN4000 10-1/2” 20” 54” 8-3/4” 22-1/4” 21-1/4” 12” 58-1/2” 2-1/2” 10” PBN5000 11” 23-1/2” 65-1/2” 11-1/2” 22” 24” 13-1/4” 69-1/2” 2-1/2” 12” Notes: Change ‘N’ to ‘L’ for LP Gas Model. No deration on LP models. All water connections are 2-1/2” Standard Features Smart Touch™ Features 87% Thermal Efficiency (AHRI) Modulating Burner with 5:1 Turndown Outdoor Ready CSD-1 Compliant Direct-Spark Ignition Low NOx Operation Sealed Combustion 160 psi Working Pressure On/Off Switch Adjustable High Limit with Manual Reset Condensate Trap w/Blocked Drain Switch Drain Valve System Sensor Outdoor Air Sensor Inlet & Outlet Temperature Sensors High-Voltage Terminal Strip Low-Voltage Terminal Strip 50 psi ASME Relief Valve Temperature & Pressure Gauge Zero Clearances to Combustible Materials Low & High Manual Reset Gas Pressure Switches 10-Year Limited Warranty (See Warranty for Details) 1-Year Warranty on Parts (See Warranty for Details) CON·X·US Remote Connect Full-Color 8” Touchscreen LCD Display Built-in Cascading Sequencer for up to 8 Boilers > Built-in Redundancy > Cascade Multiple Sized Boilers > Lead/Lag Cascade > Efficiency Optimized Cascade Front-End Loading Capability with Crest Boilers Building Management System Integration with 0-10 VDC Input Outdoor Reset Control Password Security Domestic Hot Water Prioritization > DHW tank piped with priority in the boiler loop > DHW tank piped as a zone in the system with the pumps controlled by the Smart System > DHW Modulation Limiting > Separately Adjustable SH/DHW Switching Times Low Water Flow Safety Control & Indication Inlet & Outlet Temperature Readout Freeze Protection Service Reminder Time Clock Data Logging > Hours Running, SH > Hours Running, DHW > Hours Running, Modulation Rate > Ignition Attempts > Last 10 Lockouts Ship Wt. (lbs) 1,470” 1,550” 1,696” 1,841” 2,152” *w/CAT II conversion kit Programmable System Efficiency Optimizers > Night Setback > Anti-Cycling > Outdoor Air Reset Curve > Ramp Delay > Boost Temperature & Time > Modulation Factor Control Three Pump Control > System Pump Vent Outlet 9” 10” 10” 12” 14” G 16” 16-1/4” 16-1/4” 16-1/4” 17-1/2” > Boiler Pump > Domestic Hot Water Pump High-Voltage Terminal Strip > 240V/60 Hertz/1 Phase Power Supply (PB2500-PB3000) > 208V/60 Hertz/3 Phase Power Supply (PB3500PB4000) > 480V/60 Hertz/3 Phase Power Supply (PB5000) > System Pump, Boiler Pump and DHW Pump Power Low-Voltage Terminal Strip > 24 VAC Auxiliary Device Relay > Auxiliary Proving Switch Contacts > Alarm on Any Failure Contacts > Runtime Contacts > DHW Thermostat Contacts > Unit Enable/Disable Contacts > System Sensor Contacts > DHW Tank Sensor Contacts > Outdoor Air Sensor Contacts > Cascade Contacts > 0-10V DC BMS External Control Contact > 3 Way Valve Contacts Optional Equipment Alarm Bell Outdoor Kit Low Temperature Valve Motorized Mixing Valve BMS Gateway to LON or BACnet IP BACnet MSTP Communications Modbus Communications Cupro-Nickel Heat Exchanger Wireless Outdoor Sensor Low Water Cutoff w/ Manual Reset & Test Electrical Options (shipped loose) > 208V/3PH/60 Hz (PB5000) > 480V/3PH/60 Hz (PB3500-4000) > 600V/3PH/60 Hz (PB3500-4000) 2,500,000 - 5,000,000 Btu/hr models AHRI Net AHRI Model Input Thermal Output Rating Number MBH Efficiency MBH MBH A B C D E F PBN2500 2,500 87.0% 2,175 1,891 59” 44-1/2” 29-3/4” 49-3/4” 4” 15” PBN3000 3,000 87.0% 2,610 2,270 65” 44-1/2” 29-3/4” 55-3/4” 4” 15” PBN3500 3,500 87.0% 3,045 2,648 70-1/4” 47-1/4” 29-3/4” 62-1/2” 8-1/4” 15” PBN4000 4,000 87.0% 3,480 3,026 79-3/4” 47-1/4” 29-3/4” 68-3/4” 8-1/4” 15” PBN5000 5,000 87.0% 4,350 3,783 93-1/4” 46-3/4” 32-3/4” 82-1/4” 10” 17-3/4” Registered under U.S. Patent # 7,506,617 10 500,000 to 2,000,000 Btu/hr models The Original Boiler Continues to Set the Standard In 1986, Power-Fin® redefined the industry with its space-saving design, groundbreaking efficiency and venting flexibility. Now, over 30 years later, we continue to raise the standard with an easy-to-operate touchscreen user interface, remote boiler control and enhanced communications. The advanced SMART Starting with the introduction of Power-Fin product line in 1986, we were able to provide something TOUCH™ color display that other companies weren’t focused on, efficiency includes CON·X·US and footprint. Now, 30 years later, we are proud to continue that tradition and provide some of the most remote connectivity via efficient products on the market. WiFi or Ethernet for easy control at your fingertips, from anywhere. And a simple drop-in Modbus or BACnet card allows for easy integration into a Building Management System. Enhanced Operating Control The Power-Fin now offers the industry-best SMART TOUCH™ 8˝ LCD full color touchscreen with easy-to-understand infographics. It is equipped with CON·X·US® connectivity that lets you remotely monitor and optimize the performance of the entire boiler plant. Burner Modulation Boosts Efficiency and Lowers Costs With thermal efficiency of 85%, Power-Fin boilers feature a 5:1 turndown ratio that will precisely match the firing rates to heating load requirements—at any point from 20% to full firing rate. This results in less equipment cycling for greater efficiency and cost savings. Ready for Outdoor Installation In warm-weather sites where the mechanical room is overcrowded, the Power-Fin can be easily installed either outdoors or on a rooftop. Its optional hood and screen protector make outdoor installation fast and trouble free. Venting Solutions The Power-Fin offers seven venting options for ease of installation and venting flexibility to meet the most challenging installation requirements. The Power-Fin permits air intake and exhaust lengths up to 100 ft, allowing terminations to be horizontal through a sidewall or vertical through a roof. Consult the installation and operation manual for detailed venting guidelines. 11 Power-Fin ® Boiler Dimensions & Specifications J K M B G N C P Power-Fin Boiler L Dimensions and Specifications Notes: Change ‘N’ to ‘L’ for LP Gas Model. Standard Features 85% Thermal Efficiency Modulating Burner with 5:1 Turndown > Hot Surface Ignition > Low NOx Operation > Sealed Combustion > Low Gas Pressure Operation Vertical & Horizontal Venting > Venting up to 50 Feet > Category I or Category IV Venting > Cat IV converts to Cat II w/ optional vent kit ASME Copper-Finned Tube Heat Exchanger > ASME Certified, “H” Stamped > Gasketless design > 160 psi working pressure On/Off Switch Adjustable High Limit w/ Manual Reset Flow Switch Low Air Pressure Switch Downstream Test Cocks 50 psi ASME Relief Valve Combustion Air Filtration Temperature & Pressure Gauge Zero Clearances to Combustible Material 1 Year Warranty on Parts 10 Year Limited Warranty (See Warranties for Details) No deration on LP models. Smart System Features All water connections are 2-1/2” SMART SYSTEM Operating Control > 2 line, 16 Character Display > Dual Level Password Security > Domestic Hot Water Prioritization > Built in Cascading Sequencer for up to 8 Boilers > Building Management System Integration with 0-10 VDC Input > Outdoor Reset Control with Outdoor Air Sensor > Low Water Flow Safety Control & Indication > Inlet & Outlet Temperature Readout > Freeze Protection > Service Reminder > Time Clock Data Logging > Hours Running, Space Heating > Hours Running, Domestic Hot Water > Ignition Attempts > Last 10 Lockouts Programmable System Efficiency Optimizers > Night Setback > Anti-Cycling > Outdoor Air Reset Curve > Ramp Delay > Boost Temperature & Time *w/CAT II conversion kit Three Pump Control > System Pump > Boiler Pump > Domestic Hot Water Pump High Voltage Terminal Strip > 120 VAC / 60 Hertz / 1 Phase Power Supply > Three sets of Pump Contacts with Pump Relays Low Voltage Terminal Strip > 24 VAC Auxiliary Device Relay > Auxiliary Proving Switch Contacts > Flow Switch Contacts > Alarm on Any Failure Contacts > Runtime Contacts > DHW Thermostat Contacts > Room Thermostat Contacts > System Sensor Contacts > DHW Tank Sensor Contacts > Outdoor Air Sensor Contacts > Cascade Contacts > 0-10 VDC BMS External Control Contact Firing Control Systems M Indicates 5:1 Turndown, Category IV B Indicates 2:1 Turndown, Category I F Indicates 100% On/Off Fire, Category I Optional Equipment 500,000 - 2,000,000 Btu/hr models B9/F9 Net AHRI M9 Net AHRI Model Input Thermal Output Rating Thermal Output Rating B9/F9 M9 Number MBH Efficiency MBH MBH Efficiency MBH MBH A B C D E E F G PBN0502 500 85.0% 425 370 85.0% 425 370 44-1/2” 28-1/2” 23-1/4” 34” 17-3/4” 19-1/2” 6-1/2” 6” PBN0752 750 85.0% 638 554 85.0% 638 554 52” 28-1/2” 23-1/4” 41-1/2” 17-3/4” 19-1/2” 6-3/4” 6” PBN1002 999 85.0% 850 739 85.0% 850 739 59-1/4” 28-1/2” 23-1/4” 48-3/4” 17-3/4” 19-1/2” 7-1/4” 6” PBN1302 1,300 85.0% 1,105 961 85.0% 1,105 961 67-3/4” 28-1/2” 23-1/4” 57-1/4” 17-3/4” 19-1/2” 8-1/4” 6” PBN1501 1,500 84.0% 1,260 1,096 85.0% 1,275 1,109 65-1/2” 29-3/4” 27-1/4” 58-3/4” 21” 21” 13-1/2” 8” PBN1701 1,700 84.0% 1,428 1,242 85.0% 1,445 1,257 70” 29-3/4” 27-1/4” 63-1/4” 21” 21” 13-1/2” 8” PBN2001 2,000 84.0% 1,680 1,461 85.0% 1,700 1,478 76-3/4” 29-3/4” 27-1/4” 70” 21” 21” 13-1/2” 8” Vent Sizes Ship Model B9/F9 M9 Gas Air B9/F9 M9* M9 Wt. Number H J K L M N P P Conn. Inlet Cat I Cat II Cat IV (lbs) PBN0502 8” 7-3/4” 23” 11-1/2” 11-1/4” 17-1/2” 15-1/4” 15-1/4” 1” 5” 7” 7” 4” 505 PBN0752 8” 7-3/4” 30-1/2” 11-1/2” 11-1/4” 17-1/2” 15-1/4” 15-1/4” 1-1/4” 5” 9” 9” 5” 554 PBN1002 8” 7-3/4” 37-3/4” 11-1/2” 11-1/4” 17-1/2” 15-1/4” 15-1/4” 1-1/4” 6” 10” 10” 6” 603 PBN1302 8” 7-3/4” 46-1/4” 11-1/2” 19-1/2” 17-1/2” 15-1/4” 15-1/4” 1-1/4” 6” 12” 12” 8” 652 PBN1501 10” 9-1/2” 43-1/2” 5-3/4” 22-1/4” 21-1/2” 24-1/2” 19-1/2” 1-1/2” 6” 12” 8” 6” 1,065 PBN1701 10” 9-1/2” 48” 5-3/4” 25” 21-1/2” 24-1/2” 19-1/2” 1-1/2” 7” 14” 9” 7” 1,100 PBN2001 10” 9-1/2” 54-3/4” 5-3/4” 27-1/2” 21-1/2” 24-1/2” 19-1/2” 1-1/2” 8” 14” 10” 8” 1,127 Alarm Bell Wireless Outdoor Sensor Cupro-Nickel Heat Exchanger High & Low Gas Pressure Switches w/ Manual Reset (Req. for CSD-1/FM/GE Gap) Low Water Cutoff w/ Manual Reset & Test (Req. for California Code) Modbus Communication BMS Gateway - BACnet or LonWorks Vent Kits: - Horizontal Exhaust Cap - Horizontal Air Intake Cap - Horizontal Direct Vent Kit - Category IV to Category II Conversion Kit Smart System PC Kit Registered under U.S. Patent # 7,506,617 12 ® The Foundation of Lochinvar Becomes Stronger Copper-finned tube, non-condensing appliances are the foundation of Lochinvar’s success. In 1993, Lochinvar introduced the Copper-Fin II, the first horizontal chassis, copper-finned tube boiler to operate with fan-assisted combustion. Now, the Copper-fin II is even better. Along with high thermal efficiency, gasketless heat exchangers and multiple venting options we have added Lochinvar’s exclusive SMART SYSTEM™ control. Nine models from 399,999 to 2,070,000 Btu/hr input provide you with exceptional products with a long list of new features in addition to the established features which redefined the industry. The Copper-fin II was the first proportional fired, fan-assisted boiler on the market. Every model features a small footprint for easy passage through a 36” door, low NOx – third party tested to less than 20 PPM, Stack Frames that can put twice the Btu/hr input in the same space and vent diameters up to 8” smaller than conventional atmospheric boilers. SMART SYSTEM Puts More Control and Information at Your Fingertips The most exciting addition to the Copper-Fin II is the SMART SYSTEM control. The SMART SYSTEM is an advanced, state of the art integrated operating control. We introduced the SMART SYSTEM control in 2005 and it has delivered proven operation in thousands of demanding commercial applications. The control provides the installer, owners and operators with precise temperature control and diagnostic information. Advanced features include: • 2-Line, 16 character LCD display of setup, system status and diagnostic data in words, not codes • Built-in cascade sequencer controlling up to 8 boilers • Outdoor reset adjusts setpoint based on reset curve • Domestic hot water prioritization allows the boiler to provide space heating and produce domestic hot water all in one system • 0-10 VDC BMS input to control boiler operation • Modbus protocol - optional Proportional Firing Proportional firing divides a single manifold of multiple burners into smaller, independent stages. With up to four stages of individual operation, the Smart System control can reduce the firing rate down to approximately 25% Btu/hr input. This simple but effective design matches the boiler’s firing capacity to the constantly changing system demand. Full Fire or On/Off combustion systems often fire the entire gas train in short, inefficient bursts. Stage firing delivers the Btu’s required in smoother and longer burn cycles which will improve operation and reduce component fatigue. Gasketless Heat Exchanger In 1989, Lochinvar was the first water heater manufacturer to offer gasketless cast iron & copper-finned tube heat exchangers. Our unique gasketless design enhances reliability by eliminating O-rings and gaskets found on other brands. The heat exchanger features glass lined headers and copper-finned tubes with extruded integral fins spaced 7-fins per inch for exceptional heat transfer. The heat exchanger is built to ASME construction standards for 160 psi working pressure and is backed by a ten year limited warranty. Venting Options Conventional Vents into conventional flue or vent breaching using Type B double wall vent. Powered Sidewall 13 Vents directly through the outside wall using an optional powered sidewall cap. Ideal when a vent stack is not practical. Sidewall DirectAire Vertical w/ Sidewall Outdoor Draws fresh air from inside the room. Vents up to 50 equivalent feet directly through the outside wall without the need for a powered sidewall cap. DirectAire Vertical Draws fresh air from outside and vents through conventional vertical flue. Draws fresh air from outside and vents through conventional vertical flue. Power DirectAire Horizontal Draws fresh air from outside and vents through sidewall using optional powered vent cap. Requires optional outdoor vent cap. Use when indoor space is a problem or if outdoor location gives better access. Aire-Lock Direct Vent Draws fresh air 50 equivalent feet from a sidewall. Vents horizontally up to 50 equivalent feet through the sidewall. Copper-Fin II® Boiler Dimensions & Specifications E F GAS CONNECTION 0992-2072 GAS CONNECTION 0402-0752 A G INLET AIR FILTER G D OUTLET INLET H C B Copper-Fin II Heating Boiler Dimensions & Specifications Air Inlet 6” 6” 8” 8” 10” 12” 12” 12” 12” Gas Ship Conn. Wt. (lbs) 1-1/4” 378 1-1/4” 414 1-1/4” 500 1-1/4” 543 2” 773 2” 863 2” 965 2” 1,100 2” 1,219 ® Net AHRI Model Input Thermal Output Rating Vent Number MBH Efficiency MBH MBH A B C D E F G H Size CHN0402 399 85% 339 295 31-1/2” 37-3/4” 22-1/4” 12-1/2” 7” 7” 29” 6-1/2” 6” CHN0502 500 85% 425 370 31-1/2” 45-1/2” 22-1/4” 12-1/2” 7” 7” 29” 6-1/2” 6” CHN0652 650 85% 553 481 31-1/2” 56-3/4” 22-1/4” 12-1/2” 8-1/2” 8-1/4” 29” 6-1/2” 8” CHN0752 750 85% 638 555 31-1/2” 64” 22-1/4” 12-1/2” 8-1/2” 8-1/4” 29” 6-1/2” 8” CHN0992 990 85% 842 732 36” 48-1/4” 33-1/2” 15-3/4” 8-1/2” 8-1/2” 33-3/4” 8-3/4” 10” CHN1262 1,260 85% 1,071 931 36” 58-1/2” 33-1/2” 15-3/4” 10-1/2” 9-1/2” 33-3/4” 8-3/4” 12” CHN1442 1,440 85% 1,224 1,064 36” 68-3/4” 33-1/2” 15-3/4” 10-1/2” 10-1/2” 33-3/4” 8-3/4” 12” CHN1802 1,800 85% 1,530 1,330 36” 82-1/4” 33-1/2” 15-3/4” 11” 11” 33-3/4” 8-3/4” 14” CHN2072 2,070 85% 1,760 1,530 36” 92-1/2” 33-1/2” 15-3/4” 11” 11” 33-3/4” 8-3/4” 14” Notes: Change ‘N’ to ‘L’ for LP gas models. No deration on LP models Water connections for models CH 0402-0752 are 2” NPT on 6-1/2” centers. Header increases “B” dimension 3-1/2” for models CH 0402-0752 and 6-1/4” for models CH 0992-2072. Water connections for models CH 0992-2072 are 2-1/2” NPT on 11-1/4” centers. Standard Features Smart System™ Features Certifications 85% Thermal Efficiency Proportional Firing up to 4:1 Turndown Hot Surface Ignition Low NOx Operation Sealed Combustion Low Gas Pressure Operation Vertical & Horizontal Venting Category I Venting Double Wall “B” Vent Material Category IV Venting AL29-4C Stainless Steel Vent Material ASME Copper Finned Tube Heat Exchanger ASME Certified, “H” Stamped Gasketless design 160 psi working pressure On/Off Switch Combustible Floor Rated (0992 - 2072) Adjustable High Limit w/ Manual Reset Flow Switch Low Air Pressure Switch Inlet & Outlet Temperature Sensors Easy Access Terminal Strips Downstream Test Cocks 50 psi ASME Pressure Relief Valve Temperature & Pressure Gauge 1 Year Warranty on Parts (See Warranty for Details) 10 Year Limited Warranty (See Warranty for Details) 0-10 VDC Rate Contacts SMART SYSTEM™ Operating Control 2 Line/16 Character LCD Display Built in Cascading Sequencer for up to 8 boilers Front End Loading with Crest or KNIGHT boilers Building Management System Integration with 0-10 VDC Input Outdoor Reset Control with Outdoor Air Sensor Password Security Domestic Hot Water Prioritization Low Water Flow Control & Indication Inlet & Outlet Temperature Readout Freeze Protection Service Reminder Time Clock 0-10 VDC Rate Output Condensing Protection 0-10 VDC System Pump Speed Input Data Logging Hours Running, Space Heating Hours Running, Domestic Hot Water Ignition Attempts Last 10 Lockouts Programmable System Efficiency Optimizers Night Setback Anti-Cycling Outdoor Air Reset Curve Boost Temperature & Time ANSI Z21.13/CSA 4.9 certified South Coast Air Quality Management District registered Texas Commission on Environmental Quality Three Pump Control System Pump Boiler Pump Domestic Hot Water Pump High Voltage Terminal Strip 120 VAC / 60 Hertz / 1 Phase Power Supply Pump Contacts with Pump Relay Low Voltage Terminal Strip 24 VAC Auxiliary Device Relay Output - Louvers Auxiliary Proving Switch Contacts - Louvers 3-way Valve Contacts for Low Temperature Protection Alarm on Any Failure Contacts 0-10 VDC System Pump Speed Contacts Runtime Contacts DHW Thermostat Contacts DHW Tank Sensor Contacts Unit Enable/Disable Contacts System Sensor Contacts - Supply and Return Outdoor Air Sensor Contacts Contacts for Air Louvers Contacts on Any Failure Cascade Contacts 0-10 VDC BMS External Control Contact Optional Equipment Alarm Bell High & Low Gas Pressure Switches w/ Manual Reset Cupro-Nickel Heat Exchanger Low Water Cut Off, Probe Type w/ Manual Reset & Test Modbus Communications BMS Gateway - BACnet or LonWorks Combustible Floor Kit (0402-0752) Stack Frame Thermal Static Low Temperature Protection Valve Outdoor Vent Cap Firing Codes Registered under U.S. Patent # 5,989,020 M7 Firing Code - California Code M9 Firing Code - Hot Surface Ignition with Electronic Supervision M13 Firing Code - CSD1 / Factory Mutual / GE Gap 14 Copper-Fin® Energy Efficient, Cost Effective Boilers Lochinvar first introduced Copper-Fin technology to the boiler industry some 50 years ago. Since then, we’ve continued to refine and perfect it - adding advanced fan-assisted combustion, hot surface ignition, a unique gasketless copper finned tube heat exchanger and highly efficient insulating materials. Installation Flexibility and Cost-Savings With compact sizes that use less floor space than ever before, all Copper-Fin units are narrow enough to fit through a standard 36” doorway – an advantage most commercial boilers can’t provide. Plus, thanks to special insulating materials, Copper-Fin units require only 3” clearance from combustible walls. What’s more, our Stack Frame allows you to install two units in the area normally required for one. This makes it easier to fit multiple Copper-Fin boilers into cramped mechanical rooms. And you can even use a smaller diameter vent stack - up to 8” smaller than typically required for comparable atmospheric boilers - so it saves money as well as valuable mechanical room space. Unique Copper-Fin Heat Exchanger The Lochinvar Copper-Fin boiler design uses a two pass heat exchanger. Water is circulated through a row of highly-efficient, finned copper tubes. The high rate of water flow creates a scouring action that prevents sedi ment and lime-scale buildup, common in conventional boilers, and the finned copper tubes allow maximum heat transfer efficiency. To create this special heat transfer capability, Lochinvar extrudes the fins from thick wall copper tubing to precise specifications - exactly 7 fins per inch. The result is an integrallyfinned tube with a heat transfer ratio 9 times greater than a plain copper tube. Heavy-Duty Gasketless Design What’s more, advanced casting processes allowed Lochinvar to develop a unique one-piece header system. This gasketless design provides enhanced reliability, improved durability and optimum performance - without the problems or failures common with O-rings and gaskets. Meets the Toughest Air Quality Standards Because of our unique fan-assisted combustion process, the Copper-Fin exceeds today’s toughest NOx emissions requirements. An independent certification laboratory test gave us a rating of less than 20 ppm - corrected to 3% O2. And less NOx means a cleaner environment. Enhanced to Provide Performance and Serviceability Our enhanced Copper-Fin models offer the same reliable operation, and feature a more service friendly design. The down stream test valves and referenced gas valves are now in the upper deck for easier access, and the electrical and BMS connections have been repositioned to the front of the unit for easier installation. The gas valves, which are referenced to the sealed combustion chamber, improve operational performance by monitoring the pressure in the sealed combustion chamber and adjusting gas flow to maintain the optimum air/fuel mixture. And the built-in air inlet filter reduces maintenance and improves performance by trapping dust and airborne particulates that can foul the burners and blowers. With dual sight glasses (one on each end), you can easily monitor burner performance and flame characteristics throughout the entire combustion chamber. The operator interface panel provides two-stage electronic temperature control and comprehensive diagnostic status without opening the control panel. Its user friendly design simplifies service while providing additional diagnostic information through a series of LEDs. 15 Copper-Fin Heating Boiler Model Number CBN0497 CBN0647 CBN0747 CBN0987 CBN1257 CBN1437 CBN1797 CBN2067 Copper-Fin® Copper-Fin® Boiler Dimensions & Specifications Dimensions & Specifications Input Heating Net AHRI Max Thermal Capacity Rating Gas MBH Efficiency MBH MBH A B C D E F G Conn. 495 645 745 985 1255 1435 1795 2065 81% 81% 81% 81% 81% 81% 81% 81% 401 522 603 798 1,017 1,162 1,454 1,673 349 454 524 694 884 1,010 1,264 1,455 Notes: Change ‘N’ to ‘L’ for LP gas models. No deration on LP models. 31-1/2” 31-1/2” 31-1/2” 36” 36” 36” 36” 36” 45-1/4” 56-3/4” 64” 48-1/4” 58-1/2” 68-3/4” 82-1/4” 92-1/2” 22-1/4” 22-1/4” 22-1/4” 33-1/2” 33-1/2” 33-1/2” 33-1/2” 33-1/2” 12-1/2” 12-1/2” 12-1/2” 15-3/4” 15-3/4” 15-3/4” 15-3/4” 15-3/4” 9-1/2” 9-1/2” 9-1/2” 8-1/2” 9-1/2” 10-1/2” 11” 11” 22-3/4” 28-1/2” 32” 8-1/2” 10-1/2” 10-1/2” 11” 11” 29-1/2” 29-1/2” 29-1/2” 33-3/4” 33-3/4” 33-3/4” 33-3/4” 33-3/4” Water connections for models CB 0497-747 are 2” NPT on 6-1/2” centers. Water connections for models CB 0987-2067 are 2-1/2” NPT on 11-1/4” centers. 1-1/4” 1-1/4” 1-1/4” 2” 2” 2” 2” 2” Vent Size Ship Wt.(lbs) 6” 8” 8” 10” 12” 12” 14” 14” 440 510 550 845 905 1050 1193 1350 Standard Features Optional Equipment Available Firing Systems 81% Thermal Efficiency Electronic Temperature Control Fan Assisted Combustion Sealed Combustion Chamber Stainless Steel Burners Low NOx Operation Exceeds the most Stringent Air Quality Requirements ASME Copper Finned Tube Heat Exchanger 160 psi Working Pressure Gasketless Heat Exchanger Design Pump Relay w/ Delay Down Stream Test Valve Referenced Gas Valves Loch-Heat Ceramic Tile Combustion Chamber Hot Surface Ignition Adjustable High Limit w/ Manual Reset ASME Pressure Relief Valve Temperature & Pressure Gauge Flow Switch 24 Volt Control System BMS Terminal Strip Combustion Air Filter Freeze Protection 10 Year Limited Warranty on Heat Exchanger (See warranty for details) Alarm Bell Contacts on any Failure & Runtime Contacts for Air Louvers Cupro-Nickel Heat Exchanger High & Low Gas Pressure Switch w/ Manual Reset Outdoor Reset Control Manual Reset Low Water Cut-Off w/ test Stack Frame MP2 Sequencer Outdoor Vent Cap M9 M13 M7 Hot Surface Ignition with Electronic Supervision (Standard) GE GAP/FM/CSD1 California Code Registered under U.S. Patent # 5,989,020 16 Copper-Fin® 82 % Lightweight, Flexible and Energy Efficient Copper-Fin® gas-fired atmospheric boilers are high-efficiency boilers that save space, save money, are lightweight, and are simple to service and install. Copper-Fin boilers are equipped with a built-in draft hood, a highly efficient copper finned tube heat exchanger, our own specially designed two-stage electronic control system, and they are approved for installation on combustible floors. Models are available with inputs from 315,000 to 500,000 Btu/hr. Two-Stage Control System The boiler’s two-stage electronic temperature control provides flexibility and saves fuel by closely matching heat output to system demand. On colder days the boiler fires at full output, and in warmer conditions the boiler reduces heat output to save energy and reduce boiler cycling. During the majority of the heating season, less than full boiler output is required to satisfy the heat load. For this reason, Lochinvar has developed a two-stage firing system. Two-stage firing standard equipment on all Copper-Fin boilers, provides dramatic fuel savings by reducing the firing rate 50%. And the two-stage firing control is ideal for applications utilizing indoor/outdoor reset.* *I/O reset is available as an option. Copper Finned Tube Heat Transfer The heart of the Copper-Fin boiler is its copper finned-tube heat exchanger. With this unique gasketless design, we’ve combined the best of both worlds: cast iron headers for long-lasting durability, and a copper finned-tube heat exchanger for high efficiencies and fast heat transfer. The gasketless heat exchanger design reduces the risk of leaks or system failures that are common with conventional boilers. Plus, the unit’s low-mass design means that water gets heated quickly. Not only is heat up time nearly instantaneous with these boilers, the energy consumption and operating costs are lower too. Intermittent Ignition Device The Intermittent Ignition Device is a solid-state electronic spark-to-pilot ignition system that reduces fuel consumption. Its electronic circuitry continuously monitors the system and provides pilot gas only when there is a call for heat, eliminating the need for a continuously burning pilot, and providing an additional measure of operational safety. Built-In Draft Hood The lower overall height of the draft hood makes it easier to install the Copper-Fin boiler in all applications, especially in those instances where overhead space is limited and headroom restrictions exist. Serviceability This boiler is as flexible and convenient to install and service as it is efficient and compact. The heavy-duty stainless steel burners can easily be adapted for use with either natural or liquefied petroleum (LP) gas, and the boiler’s design allows for easy access to all major components for servicing. The heat exchanger is designed to slide out the front of the boiler for faster maintenance, and Lochinvar backs it up with an exclusive 10-year Limited Warranty. For more information, call your Lochinvar dealer today. 17 Copper-Fin Boiler Copper-Fin® Copper-Fin® Boiler Dimensions & Specifications Dimensions & Specifications Net AHRI Model Input Thermal Output Rating Number MBH Efficiency MBH MBH A B C D CBN315 CBN360 CBN399 CBN500 315 360 399 500 82.0% 82.0% 82.0% 82.0% 258 295 328 410 224 257 285 357 Notes: Change ‘N’ to ‘L’ to denote L.P. gas models No deration for L.P. models. Water Connections are 2” NPT on 6-1/4” centers. Performance data is based on manufacturer test results. 29-1/2” 29-1/2” 29-1/2” 34-1/2” 32-1/4” 35-1/4” 44-1/2” 52-1/2” 21-1/2” 21-1/2” 22” 22” 16-1/4” 17-3/4” 22-1/4” 26-1/4” Gas Conn. Vent Size Ship. Wt.(lbs) 3/4” 1” 1” 1” 8” 9” 10” 10” 245 255 320 345 Standard Features Optional Equipment Firing Controls 82% Thermal Efficiency ASME Copper Finned Tube Heat Exchanger Gasketless Heat Exchanger Design Two Stage Intermittent Electronic Ignition 160 PSI Working Pressure Pump Relay Two Stage Solid State Temperature Control Two Stage Gas Valve with Built-In Manual Shut-Off Automatic Reset High Limit ASME Pressure Relief Valve Temperature & Pressure Gauge Diagnostic Flash Codes Built-In Draft Diverter CSA Design Certified for Alcove Installation CSA Design Certified for Installation on Combustible Floor Stainless Steel Burners Loch-Heat Ceramic Tile Combustion Chamber 24 Volt Control System 10 Year Limited Warranty on Heat Exchanger (See warranty for details) Adjustable High Limit w/ Manual Reset Contacts on any Failure Contacts for Air Louvers Flow Switch Outdoor Air Reset Control Low Water Cut-Off Stack Frame Pump Delay/Freeze Protection MP2 Sequencer 3-Way Low Temperature Valve M9 - Two-Stage Intermittent Spark Ignition (Standard) M13 - GE GAP/FM/IRI M7 - California Code 18 The Best You Can Buy KNIGHT® is recognized for its reliable, proven performance and high quality standards. Its award winning design assures contractors and home owners peace of mind and long term savings in operating costs. Lochinvar has raised the KNIGHT standard to even greater heights. The SMART SYSTEM™ control with color display gives installers and maintenance personnel a greater level of control than ever before. It’s easy to access all the information they need to setup, troubleshoot and monitor all boiler functions. Additionally, two cascading options allow the installer to fine-tune sequencing of multiple boiler installations. More than ever, KNIGHT is the best choice for traditional hydronic space heating, radiant floor heating and indirect domestic hot water applications. Control The SMART SYSTEM™ is the most advanced integrated boiler control on the market today. Now the CON·X·US® mobile communication platform allows SMART SYSTEM to go where no other boiler has gone before.† † CON·X·US control board sold separately CON·X·US provides the ability to monitor and manage multiple KNIGHT heating boilers without ever stepping into the mechanical rooms. CON·X·US will send alerts via text or e-mail notifying of changes in system status, and anytime, from anywhere, a user can check system status and re-program any boiler function. Once downloaded, the free CON·X·US mobile application allows for remote access to all SMART SYSTEM functions using an internet-capable device. Built-in Cascading Sequencer When multiple KNIGHT boilers are installed together, the SMART SYSTEM built-in sequencer can be set for “Lead-Lag” cascade or “Efficiency Optimized” cascade operation. Advanced Negative Regulation Technology KNIGHT safely and reliably operates with supply gas pressures as low as 4 inches water column. Plus “Neg/Reg” technology automatically adjusts gas pressure to ensure the correct volume of fuel and air entering the burner. Direct-Spark Ignition With each call for heat, two electrodes ignite the fuel/air mixture. A third electrode then senses for flame. The SMART SYSTEM will generate a soft lockout and display a fault if ignition does not occur. Fully Modulating Burner with 5:1 Turndown The SMART SYSTEM allows fully modulating combustion with 5:1 turndown. The burner can fire as low as 20% of maximum input and modulates the firing rate up to 100% as demand increases. A woven stainless steel mesh enclosed burner tube fires in a 360° pattern along the entire length of the primary heat exchanger. Two-in-One Stainless Heat Exchanger A primary heat exchanger combined with a secondary heat exchanger captures flue gas heat and condenses to utilize available latent energy. The stainless steel, pH-tolerant design features a weld-sealed assembly with no O-rings or gaskets and does not require special glycol. ASME Section IV approved and stamped. 19 KNIGHT® Boiler Dimensions & Specifications Models: KBN 081-211 Model: KBN286 Dimensions and Specifications Knight Heating Boiler Input Heating NET AHRI Model Min. Max. Capacity Rating Number MBH MBH AFUE MBH MBH KBN081 KBN106 KBN151 KBN211 KBN286 16 21 30 42 57 80 105 150 210 285 95.0% 95.0% 95.0% 95.0% 95.0% 74 97 139 196 267 64 84 121 170 232 A C D E F G H I J K Gas Water Air Vent Ship Conn. Conn. Inlet Size Wt. (lbs) 33-1/4" 33-1/4" 33-1/4" 33-1/4" 42-1/4" 14" 7" 5-3/4" 14" 6-1/2" 5-3/4" 18" 12-1/4" 11-1/2" 22-1/4" 16-1/2" 15-3/4" 19-3/4" 12-3/4" 13-1/2" 5" 4-1/2" 10" 14-1/4" 6" 3" 1-1/2" 1-1/2" 5-1/4" 2" 20-1/2" 20-1/2" 21-1/4" 21-1/4" 34" 22" 22" 23" 23" 31" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 11-3/4" 6-1/2" 1/2" 6-1/2" 1/2" 12" 1/2" 16-1/4" 1/2" 4-1/4" 3/4" 1" 1" 1" 1" 1-1/4" 3" 3" 3" 3" 4" 3" 125 3" 129 3" 157 3" 172 4" 224 Notes: Indoor installation only. All information subject to change. Change "N" to "L" for LP gas models. Net ratings based on piping and pick-up allowance of 1.15 Smart System™ Features SMART SYSTEM Digital Operating Control > Multi-Color Graphic LCD Display with Navigation Dial and Soft Keys Three Setpoint Temperature Inputs Built-in Cascading Sequencer for up to 8 Boilers > Cascade Multiple Sized Boilers > Lead Lag > Efficiency Optimization > Front End Loading Capability with Copper Fin II Outdoor Reset Control with Outdoor Air Sensor > Programmable for Three Reset Temperature Inputs Programmable System Efficiency Optimizers > Night Setback w/Override Function > DHW Night Setback w/Override Function > Anti-Cycling > Outdoor Air Reset Curve > Ramp Delay > Boost Temperature & Time Three Pump Control > System Pump with Parameter for Continuous Operation > Boiler Pump with Variable Speed Pump Control > Domestic Hot Water Pump Domestic Hot Water Prioritization > DHW tank piped with priority in the boiler loop > DHW tank piped as a zone in the system with the pumps controlled by the Smart System > DHW Modulation Limiting > Separately Adjustable SH/DHW Switching Times* Building Management System Integration > 0-10 VDC Input to Control Modulation or Set Point > 0-10 VDC Modulation Rate Output > 0-10 VDC Input Signal from Variable Speed System Pump* > 0-10 VDC Input to Enable/Disable call for heat Standard Features High-Voltage Terminal Strip > 120 VAC / 60 Hertz / 1 Phase Power Supply > Three Sets of Pump Contacts Low Voltage Terminal Strip > 24 VAC Device Relay > Proving Switch Contacts > Flow Switch Contacts > Alarm on Any Failure Contacts > Runtime Contacts > DHW Thermostat Contacts > 3 Space Heat Thermostat Contacts > System Sensor Contacts > DHW Tank Sensor Contacts > Outdoor Air Sensor Contacts > Cascade Contacts > 0-10 VDC BMS External Control Contact > 0-10 VDC Boiler Rate Output Contacts > 0-10 VDC Variable Speed System Pump Signal Input > 0-10 VDC Signal to Control Variable Speed Boiler Pump > Modbus Contacts Time Clock Data Logging > Hours Running, Space Heating > Hours Running, Domestic Hot Water > Ignition Attempts > Last 10 Lockouts Access to BMS Settings through Graphic LCD Display Maintenance Reminder > Custom Maintenance Reminder with Contractor Info > Installer Ability to De-activate Service Reminder Low-Water Flow Safety Control & Indication Dual Level Password Security Customizable Freeze Protection Parameters Energy Star™ Qualified 95% DOE AFUE Efficiency Modulating Burner with 5:1 Turndown > Direct-Spark Ignition > Low-NOx Operation > Field Convertible from Natural to LP Gas ASME Stainless Steel Heat Exchanger > 30 psi ASME Relief Valve Vertical & Horizontal Direct-Vent > PVC, CPVC, Polypropylene or SS Venting up to 100 feet Smart System Control Condensate Trap Other Features Automatic Reset High Limit Adjustable High Limit w/Manual Reset Boiler Circulating Pump Adjustable Leveling Legs Zero Clearances to Combustible Materials 5-Year Parts Warranty 12-Year Limited Warranty (See Warranty for Details) Optional Equipment CON·X·US Remote Connect Modbus Communication Condensate Neutralization Kit Multi Temperature Loop Control Flow Switch Low-Water Cutoff w/Manual Reset & Test Alarm Bell Concentric Vent Kit Stack Frame BMS Gateway - BACNet or LonWorks Sidewall Vent Termination Wireless Outdoor Sensor Firing Codes M9 Standard Construction M7 California Code *Exclusive feature available only from Lochinvar 20 Money-Saving 95% Efficiency and Easier than Ever to Install The KNIGHT floor standing fire tube boiler features reduced installation footprint for flexibility in boiler placement. Plus, all connections are on the top and left side, so KNIGHT is an easy drop in replacement for older, less efficient boilers. Six models offer inputs from 55,000 to 285,000 Btu/hr. Use Existing Piping to Reduce Costs The KNIGHT fire tube boiler operates with low pressure drop. The design incorporates a small volume of water in the heat exchanger. This allows the boiler to be installed in a primary/secondary or a full-flow piped system. There is no need to change the piping to accommodate the boiler. The boiler adapts to the system. This flexibility allows for a faster, more cost-effective boiler upgrade. 10:1 Turndown Ratio Optimizes Performance Modulation turndown up to 10:1 means the firing rate automatically changes as the heat load varies. A KHN110 KNIGHT boiler fires at its maximum 110,000 Btu/hr rate when load is highest, then “turns down” to as low as 10% (11,000 Btu/hr) as load decreases. A modulating boiler runs smoothly and efficiently, without frequent on/off cycling Safe, Reliable NEG/REG Technology KNIGHT boilers can operate with low gas supply pressure. Negative Regulation uses a pre-mix gas system instead of relying on utility pressure through the gas valve. The result is steady operation in low gas pressure systems or when gas demand is highest. Automatic fan control fine-tunes the air/fuel ratio, providing superior combustion throughout the operating range. Superior Direct Venting Flexibility KNIGHT boilers can be installed with direct-vent air intake and exhaust runs up to 100 equivalent feet, using PVC, CPVC, polypropylene or AL29-4C stainless steel vent pipe. BOILER CONTROL, FROM ANYWHERE. From wherever you are, the CON·X·US® option lets you use any internet-capable device to link up with the SMART SYSTEM™ on an unlimited number of KNIGHT boilers. > Do regular CON·X·US checks for all your KNIGHT customers, and let them know you’re monitoring their boiler’s performance. > Adjust setpoints, domestic hot water, reset curves, pump delays and more, using the CON·X·US interactive display. With CON·X·US, you’re always in touch and in control. Optional CON·X·US control board is sold separately. 21 > Status alerts via text or e-mail let you know when a KNIGHT boiler needs attention. KNIGHT® Boiler Dimensions & Specifications AIR INLET A WATER OUTLET GAS CONNECTION FLUE 2-3/4" 43-3/8" 2-7/8" HIGH-VOLTAGE ELECTRICAL CONNECTIONS B D LOW-VOLTAGE ELECTRICAL CONNECTIONS 19" F G H WATER INLET C 16" CONDENSATE DRAIN I 1/4" - 1-1/4" ADJUSTABLE J E Dimensions and Specifications Knight Heating Boiler Input MBH Model Number Min Max AFUE Heating Capacity MBH KHN055 8.2 55 95% 51 44 6" 8-3/8" 11-1/8" 10-1/2" 13-1/4" 37-1/2" 32-5/8" 32-1/4" 13-1/4" 3-3/8" 1/2" KHN085 8.5 85 95% 79 69 6" 8-3/8" 11-1/8" 10-1/2" 13-1/4" 37-1/2" 32-5/8" 32-1/4" 13-1/4" 3-3/8" 1/2" KHN110 11 110 95% 102 89 7-3/8" 9-3/4" 11-1/8" 10-5/8" 14-5/8" 37-3/4" 33" 32-1/2" 14" 4-5/8" KHN155 15.5 155 95% 144 125 7-3/8" 9-3/4" 11-1/8" 10-5/8" 14-5/8" 37-3/4" 33" 32-1/2" 14" KHN199 19.9 199.9 95% 185 161 7-1/2" 10-1/2" 11-1/8" 11-5/8" 15-3/8" 38" 33" 32-3/4" KHN285 28.5 285 95% 264 229 7-1/2" 10-1/2" 11-1/8" 11-5/8" 15-3/8" 38" 33" 32-3/4" Net MBH A B C D E F G H I J Gas Water Connect. Connect. Air Inlet Vent Size Ship. Wt. (lbs) 1" 2" 2" 160 1" 2" 2" 165 1/2" 1" 3" 3" 170 4-5/8" 1/2" 1" 3" 3" 175 14" 4-5/8" 1/2" 1-1/4" 3" 3" 195 14" 4-5/8" 1/2" 1-1/4" 3" 3" 205 Notes: Indoor installation only. All information subject to change. Change "N" to "L" for LP gas models. Net ratings based on piping and pick-up allowance of 1.15 Smart System™ Features > Smart System Digital Operating Control Multi-Color Graphic LCD Display w/Navigation Dial, Soft Keys and Loch-N-Link™ USB programming > Three Boiler Setpoint Temperature Inputs Plus Domestic Hot Water Prioritization > Built-in Cascading Sequencer for up to 8 Boilers, with Cascade Redundancy Multiple Size Boiler Cascade Lead Lag Efficiency Optimization Front End Loading Capability > Outdoor Reset Control with Outdoor Air Sensor Programmable for Three Reset Temperature Inputs > Programmable System Efficiency Optimizers SH Night Setback DHW Night Setback Anti-Cycling Outdoor Air Reset Curve Ramp Delay Modulation Factor Control Boost Temperature & Time > Four Pump Control System Pump with Parameter for Continuous Operation Boiler Pump with Variable Speed Control Domestic Hot Water Pump Domestic Hot Water Recirculation > Domestic Hot Water Prioritization DHW tank piped with priority in the boiler loop DHW tank piped as a zone in the system with the pumps controlled by the SMART SYSTEM DHW Modulation Limiting Separately Adjustable Space Heat/DHW Switching Times > Building Management System Integration 0-10 VDC Input to Control Modulation or Setpoint 0-10 VDC Modulation Rate Output 0-10 VDC Input to Enable/Disable Call for Heat > Access to BMS Settings through Graphic LCD Display > High-Voltage Terminal Strip 120 VAC / 60 Hertz / 1 Phase Power Supply Three Sets of Pump Contacts > Low-Voltage Terminal Strip DHW Recirculation Pump Start/Stop 24 VAC Device Relay Proving Switch Contacts Flow Switch Contacts Alarm on Any Failure Contacts Runtime Contacts DHW Thermostat Contacts 3 Space Heat Thermostat Contacts System Sensor Contacts DHW Tank Sensor Contacts Outdoor Air Sensor Contacts Cascade Contacts 0-10 VDC BMS External Control Contact 0-10 VDC Boiler Rate Output Contacts 0-10 VDC Variable Speed System Pump Signal Input 0-10 VDC Signal to Control Variable Speed Boiler Pump Modbus Contacts > Time Clock > Data Logging Hours Running, Space Heating Hours Running, Domestic Hot Water Ignition Attempts Last 10 Lockouts > Maintenance Reminder Custom Maintenance Reminder with Contractor Contact Information Installer Ability to De-activate Service Reminder > Low-Water Flow Safety Control & Indication > Password Security > Customizable Freeze Protection Parameters Standard Features > ENERGY STAR Most Efficient Product > 95% DOE AFUE Efficiency > Modulating Burner with up to 10:1 Turndown Direct Spark Ignition Low NOx Operation > ASME Stainless Steel Heat Exchanger 30 PSI ASME Relief Valve > Vertical & Horizontal Direct Vent PVC, CPVC, Polypropylene or SS Venting up to 100 feet > Smart System Control > Condensate Trap > Other Features Automatic Reset High Limit Adjustable High Limit w/Manual Reset Boiler Circulating Pump Zero Clearances to Combustible Materials 12-Year Limited Warranty (See Warranty for Details) 5-Year Limited Parts Warranty Optional Equipment CON·X·US® Remote Connect Modbus Communication BACnet MSTP Flow Switch Low-Water Cutoff w/Manual Reset & Test Alarm Bell Concentric Vent Kit Condensate Neutralization Kit BMS Gateway to LON or BACnet IP Multi-Temperature Loop Control Sidewall Vent Termination Wireless Outdoor Sensor LP Gas Conversion Kit > Firing Codes M9 Standard Construction M7 California Code 22 Money-Saving 95% Efficiency and Easier Than Ever to Install The KNIGHT® fire tube wall mount boiler allows for a more flexible installation with top and bottom water connections**. Multiple water connection locations add flexibility by allowing boiler connections as close as possible to the system piping, reducing installation cost, complexity and the amount of piping needed for a job. The KNIGHT fire tube boiler operates with low pressure drop. The design incorporates a small volume of water in the heat exchanger allowing the boiler to be installed in a primary/secondary or a full-flow piped system. There is no need to change the piping to accommodate the boiler. The boiler adapts to the system. This flexibility allows for a faster, more cost-effective boiler upgrade. **Not included on WHN400 The CON·X·US® mobile communication platform allows SMART SYSTEM to go where no other boiler has gone before.† CON·X·US provides the ability to monitor and manage multiple KNIGHT heating boilers without ever stepping into the mechanical rooms. CON·X·US will send alerts via text or e-mail notifying of changes in system status, and anytime, from anywhere, a user can check system status and re-program any boiler function. Once downloaded, the free CON·X·US mobile application allows for remote access to all SMART SYSTEM functions using an internet-capable device. Updated SMART SYSTEM Control Newest version of the SMART SYSTEM allows for easier setup and navigation of parameters. New features include DHW recirculation pump control, LOCK-NLINK® USB programming, larger user interface, cascade leader redundancy and modulation factor for fine tuning aggressiveness. 10:1 Turndown Ratio Optimizes Performance Modulation turndown up to 10:1 means the firing rate automatically changes as the heat load varies. A WHN111 KNIGHT boiler fires at its maximum 110,000 Btu/hr rate when load is highest, then “turns down” to as low as 10% (11,000 Btu/hr) as load decreases. A modulating boiler runs smoothly and efficiently, without frequent on/off cycling. **Not included on WHN400 Safe, Reliable NEG/REG Technology KNIGHT boilers can operate with low gas supply pressure. Negative Regulation uses a pre-mix gas system instead of relying or utility pressure through the gas valve. The result is steady operation in low gas pressure systems or when gas demand is highest. Automatic fan control fine-tunes the air/fuel ratio, providing superior combustion throughout the operating range. Superior Direct-Venting Flexibility KNIGHT boilers can be installed with direct-vent air intake and exhaust runs up to 100 equivalent feet, using PVC, CPVC, polypropylene or AL29-4C stainless steel vent pipe. 23 C KNIGHT® Boiler Dimensions & Specifications C C M N LOW VOLTAGE ELECTRICAL FLUE L L FLUE INLET L A INLET F K OUTLET G E OUTLET COIN VENT G F D E A COIN VENT K E A O F H H I I OUTLET AIR VENT K G J J AIR VENT B CONDENSATE DRAIN CONDENSATE DRAIN D D O COIN VENT CONDENSATE DRAIN INLET M FLUE N O HIGH VOLTAGE ELECTRICAL CONNECTIONS HIGH VOLTAGE ELECTRICAL CONNECTIONS LOW VOLTAGE CONNECTIONS ELECTRICAL CONNECTIONS M N HIGH VOLTAGE ELECTRICAL CONNECTIONS LOW VOLTAGE ELECTRICAL CONNECTIONS H J B I AIR VENT Knight Heating Boiler B Dimensions and Specifications Input Heating NET AHRI A B C D E F G H I J K L M N O Gas Water Air Vent Ship Model Max. Min. Capacity Rating Conn. Conn. Inlet Size Wt. (lbs) Number MBH MBH AFUE MBH MBH 333-1/4”18-1/2” 16” 11-3/4” 9” 3-1/2” 3-3/4” 1-1/2” 3” 6-1/8” 7-1/4” 3-3/4” 6-1/2” 4-1/2” 8-1/2” WHN056 55 8.3 95% 51 44 33-1/4” 18-1/2” 16” 11-3/4” 9” 3-1/2” 3-3/4” 1-1/2” 3” 6-1/8” 7-1/4” 3-3/4” 8-1/2” 4-1/2” 8-1/2” WHN086 85 8.5 95% 79 69 33-1/4” 18-1/2” 19” 14-1/2” 8-3/2” 5” 7-3/4” 1-1/8” 12-3/8” 4-1/4” 11-1/4” 3” 5-1/4” 5-1/8” 10” WHN111 110 11 95% 102 89 2000544065 33-1/4” 18-1/2” 19” 14-1/2” 8-1/2” 5” 7-3/4” 1-1/8” 12-3/8” 4-/14” 11-1/4” 3” 5-1/4” 5-1/8” 10” WHN156 155 15.5 95% 144 125 33-1/4” 18-1/2” 19” 14-1/2” 11” 6-1/4” 7-3/4” 1-1/2” 12-3/8” 4-1/4” 9-1/2” 3” 5-1/4” 5-1/2” 10-3/4” WHN200 199.9 19.9 95% 185 161 33-1/4” 18-1/2” 21-3/4” 16-1/2” 11-1/8” 6-1/4” 7-3/4” 1-1/2” 12-3/8” 16-3/8” 12-1/4” 3-1/8” 5-1/4” 4” 15-1/8” WHN286 285 28.5 95% 264 229 35-1/2” 25” 21-3/4” 17-1/2” 12-1/2” 9-1/4” 9-1/2” 2-1/4” 13-1/4” 21-1/2” 9” 4-3/4” 4” 22-1/2” 3-3/4” WHN400 399 80 94.4%* 377# 328 *Thermal Efficiency% # Gross Output MBH **10:1 Turndown ratio and top and bottom water connections are not included on WHN400. WHN400 operates with a 5:1 turndown. 1/2” 1” 1/2” 1” 1/2” 1” 1/2” 1” 1/2” 1-1/4” 2000544065 1/2” 1-1/4” 3/4” 1-1/2” 2” 2” 3” 3” 3” 3” 4” 2” 2” 3” 3” 3” 3” 4” 139 142 159 166 175 184 213 2000544065 Information subject to change without notice. Change “N” to “L” for LP gas models. The Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15. Lochinvar should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc. The ratings have been determined under the provisions governing forced draft burners. Smart System™ Features > Smart System Digital Operating Control Multi-Color Graphic LCD Display w/Navigation Dial, Soft Keys and Loch-N-Link USB programming > Three Boiler Setpoint Temperature Inputs Plus Domestic Hot Water Prioritization > Built-in Cascading Sequencer for up to 8 Boilers, with Cascade Redundancy Multiple Size Boiler Cascade Lead Lag Efficiency Optimization Front End Loading Capability > Outdoor Reset Control with Outdoor Air Sensor Programmable for Three Reset Temperature Inputs > Programmable System Efficiency Optimizers SH Night Setback DHW Night Setback Anti-Cycling Outdoor Air Reset Curve Ramp Delay Modulation Factor Control Boost Temperature & Time > Four Pump Control System Pump with Parameter for Continuous Operation Boiler Pump with Variable Speed Control Domestic Hot Water Pump Domestic Hot Water Recirculation > Domestic Hot Water Prioritization DHW tank piped with priority in the boiler loop DHW tank piped as a zone in the system with the pumps controlled by the SMART SYSTEM DHW Modulation Limiting Separately Adjustable Space Heat/DHW Switching Times > Building Management System Integration 0-10 VDC Input to Control Modulation or Setpoint 0-10 VDC Modulation Rate Output 0-10 VDC Input to Enable/Disable Call for Heat > Access to BMS Settings through Graphic LCD Display > High-Voltage Terminal Strip 120 VAC / 60 Hertz / 1 Phase Power Supply Three Sets of Pump Contacts > Low-Voltage Terminal Strip DHW Recirculation Pump Start/Stop 24 VAC Device Relay Proving Switch Contacts Flow Switch Contacts Alarm on Any Failure Contacts Runtime Contacts DHW Thermostat Contacts 3 Space Heat Thermostat Contacts System Sensor Contacts DHW Tank Sensor Contacts Outdoor Air Sensor Contacts Cascade Contacts 0-10 VDC BMS External Control Contact 0-10 VDC Boiler Rate Output Contacts 0-10 VDC Variable Speed System Pump Signal Input 0-10 VDC Signal to Control Variable Speed Boiler Pump Modbus Contacts > Time Clock > Data Logging Hours Running, Space Heating Hours Running, Domestic Hot Water Ignition Attempts Last 10 Lockouts > Maintenance Reminder Custom Maintenance Reminder with Contractor Contact Information Installer Ability to De-activate Service Reminder > Low-Water Flow Safety Control & Indication > Password Security > Customizable Freeze Protection Parameters Standard Features > 95% DOE AFUE Efficiency (56-286) > Modulating Burner with up to 10:1 Turndown** Direct Spark Ignition Low NOx Operation > ASME Stainless Steel Heat Exchanger 30 PSI ASME Relief Valve > Top and bottom water connections (MNPT)** > Vertical & Horizontal Direct Vent PVC, CPVC, Polypropylene or SS Venting up to 100 feet > SMART SYSTEM Control > Condensate Trap > Other Features Automatic Reset High Limit Adjustable High Limit w/Manual Reset Boiler Circulating Pump Zero Clearances to Combustible Materials 15-Year Limited Warranty (See Warranty for Details) 5-Year Limited Parts Warranty Optional Equipment CON·X·US Remote Connectivity Modbus Communication BACnet MSTP Flow Switch Low-Water Cutoff w/Manual Reset & Test Alarm Bell Concentric Vent Kit Condensate Neutralization Kit BMS Gateway to LON or BACnet IP Multi-Temperature Loop Control Sidewall Vent Termination Wireless Outdoor Sensor LP Gas Conversion Kit > Firing Codes M9 Standard Construction M7 California Code 24 FIRE TUBE COMBI ™ A Game-Changer In Combi Water Heating Lochinvar has long been the innovation leader in commercial boilers - and now it’s bringing that engineering excellence to residential combi boilers. Lochinvar’s legendary reliability and performance are now available for apartments and homes, where the combi boiler’s next-generation fire tube design can provide hot water supply and space heating faster and more efficiently than ever before. The NOBLE™ combi boiler provides a space-saving choice for builders and specifiers, lowering installation costs by reducing the mechanical equipment needed to provide rapid, reliable hot water supply and efficient space heating. It also gives plumbing contractors a money-saving alternative for single-family housing with 1 or 2 bathrooms. Advanced Electronic Control The backlit, user-friendly LCD display provides diagnostic information and system status in real words, not codes. The Set-Up Wizard display makes it simple to set system parameters in just minutes. What makes the NOBLE The Best Combi Boiler? DELIVERS MORE HOT WATER It’s sized large enough to quickly meet domestic hot water (DHW) load. Provides DHW from 2.6 (NKC110) to 4.8 gpm (NKC199) at a 77°F temperature rise. FASTER DHW RESPONSE TIME With many combi boilers, when you turn on a hot water faucet, you initially get hot water and then a brief burst of cold water before the hot water resumes. Thanks to its patent-ending control technology, this combi boiler eliminates this cold water “sandwich”. 10:1 TURNDOWN RATIO Operates as low as 10% of the maximum firing rate, preventing on/off short cycling at the lowest DHW demands or small heating demands. 25 F G I C FRONT B RELIEF VALVE AIR INTAKE NKC 150-199 D E E TOP G I D E E F F F F A K H NKC110 TOP NOBLE Combi Boiler R GAS N O C AIR INTAKE C I FLUE B ™ CONDENSATE Dimensions and Specifications WATER S INLET/OUTLET Input Heating NET AHRI A B C D E Model Max. Min. Capacity Rating Number MBH MBH AFUE MBH MBH NKC110N K NKC150N NKC199N 110 150 199 11 15 20 95.0% 95.0% 95.0% P 102 139 MNTU 185 89 121 161 32-1/2” 32-1/2” 32-1/2” 17-1/4” 18-3/4” 18-3/4” 18” 18” 18” 14-3/4” 6-3/4” 5-1/2” 2” 2-1/2” 2-1/4” 3-1/2” 6-1/4” 5-1/2” 8-3/4” 2-3/4” 2-3/4” 13-1/2” 13-1/2” 13-1/2” 2-3/4” 3” 2-3/4” 9” 9” 9 1/2” 10-1/2” 11-1/2” 10-1/2” A A L Model H IQ J K L M N O P Q O Number NKC110N NKC150N NKC199N RELIEF VALVE RELIEF VALVE FLUE BOTTOM AIR INTAKE B L PQ I H HIGH VOLTAGE CONNECTIONS J MN MT U O P H NKC110 G G C H NKC110 S R J D D G I GAS Q R FLUE FIRE TUBE COMBI H NOBLE™ Combi Boiler Dimensions & Specifications R 2-3/4” 2-3/4” 2-3/4” Gas Conn. Water Conn. F G 6-1/2” 6-3/4” 6-3/4” 2-3/4” 11-3/4” 11-1/2” Air Inlet Vent Size Ship Wt. (lbs) 5” 5” 2-3/4” 14-1/2” 12-3/4” 5” 1/2” 1” 3” 3” 139 6-1/4” 13-3/4” 6” 1/2” 1” 3” 3” 142 5-1/2” 13” 5-1/4” 1/2” 1” 3” 3” 159 HIGH VOLTAGE HIGH VOLTAGE Notes: Indoor installation only. All information subject to change. Change "N" to "L" for LP gas models. *The Net AHRI Water Ratings shown are based on a piping and pickup allowance ofCONNECTIONS 1.15. R R J J 2000534158 Standard Features > Smart System Digital Operating Control > SMART CONTROL Digital Operating Control > ENERGY STAR Most Efficient Recognition > 95% DOE AFUE Efficiency K K > Modulating Burner with 10:1 Turndown LCD Display with words not codes > Outdoor Reset Control with Outdoor Air Sensor > Programmable System Efficiency Optimizers DHW Response Time DHW Pre Heat Outdoor Air Reset Curve > Two Pump Control System Pump Boiler Pump > High-Voltage Junction Box 120 VAC / 60 Hertz / 1 Phase Power Supply > Low Voltage Terminal Strip Air Handler Interlock Flow Switch Contacts Low-Water Cutoff Connection System Sensor Contacts Outdoor Air Sensor Contacts Cascade Contacts Direct-Spark Ignition Low-NOx Operation S S Smart System™ Features GAS GAS CONNECTIONS CONDENSATE CONDENSATE WATER WATER INLET/OUTLET INLET/OUTLET Optional Equipment P Q > ASME Stainless Steel O O Heat Exchanger 50 psi Working Pressure w/ASME Relief Valve > Vertical & Horizontal Direct-Vent PVC, CPVC, Polypropylene or SS Venting up to 100 feet Low-Water Cutoff w/Manual Reset & Test Concentric Vent Kit MNTU M N T U Condensate Neutralization Kit Sidewall Vent Termination P Floor L Stand L Q Wireless Outdoor Sensor Nat to LP Gas Conversion Kit Isolation/Flush Valves Firing Codes > M9 Standard Construction/California Code > Condensate Trap > Other Features Automatic Reset High Limit Adjustable High Limit w/Manual Reset Built-in Circulating Pump Wall-Mount Bracket Zero Clearances to Combustible Materials 10-Year Warranty (See Warranty for Details) 5-Year Parts Warranty 2000534158 *Lochinvar should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc. *The ratings have been determined under the provisions governing forced draft burners. > Time Clock for Data Logging Last 10 Lockouts > Low-Water Flow Safety Control & Indication > Password Security > Built-in Cascading Sequencer for up to 8 units 26 The Best All-Around Value in Today’s Home Heating Market This modulating/condensing residential heating boiler offers fuel cost savings and outstanding quality at lower cost than other high-efficiency designs. With gas inputs from 40,000 to 120,000 Btu/hr, these wall-mount boilers can handle the heating load for almost any home. Stainless Steel Heat Exchanger with ASME ‘H’ Stamp A commercial-grade ASME certified heat exchanger exemplifies the highest standards for design, materials and manufacturing. Fully Modulating Burner Modulation adjusts the firing rate of the boiler to match the heat loss of the home, reducing burner cycling and increasing overall system efficiency. Outdoor Reset with Sensor Monitors outdoor temperature to help CADET maintain a steady, consistent indoor comfort level year-round. Allows boiler control to “reset” indoor water temperature as needed when outdoor temperatures fluctuate. Push-Button Digital Control Constant display of actual output temperature, and easy adjustment of setpoint. Venting Versatility CADET can be installed with a variety of venting configurations, including vertical or sidewall direct venting. Air intake and exhaust vent runs up to 100 feet can be utilized to meet the most challenging installation requirements. 3” polypropylene, PVC, CPVC or stainless steel pipe can be used. This venting flexibility is ideal for projects that will require new vent material when a non-condensing boiler is being replaced. Expanded Polypropylene (EPP) Jacket Lightweight for easier handling. Deadens sound for quieter operation. Highly dent and scratch-resistant. 94% AFUE Efficiency Reduces Heating Bills For example, over 6 years, CADET could save over $1,400 in fuel costs.* Depending on where it is installed, CADET may qualify for Energy Tax Credits. $1,600 $1,200 $800 $400 1 YR 27 2 YR 3 YR 4 YR 5 YR 6 YR *Fuel savings are compared to an 80% AFUE boiler and based on a 70,000 Btu heating load with 2,000 hours of operation with a fuel cost of $1.13 per therm. VENT A CADET® Boiler Dimensions & Specifications19-1/2" AIR 15-3/4" Top View Bottom View 7-3/4" Side View 2-1/2" 19-1/2" AIR 15-3/4" 5-1/4" OUTLET GAS 1/2" NPT 13-3/4" 7-3/4" 2-1/2" VENT 5-1/4" B C D 13-3/4" INLET VENT A E 3-1/2" CONDENSATE DRAIN 9-1/4" 11" GAS 1/2" NPT A OUTLET GAS 1/2" NPT B B C D OUTLET E Input Heating Net AHRI A INLET B 3-1/2" C D E Water Air Vent Ship Model Max. Min. Capacity RATING Conn. Inlet Size Wt. (lbs) Number MBH MBH AFUE MBH MBH CONDENSATE 9-1/4" C 26” 4-1/4” 5-1/4” 4”DRAIN 2-1/2” 3/4” 2” 2” 94 CDN040 40 9 94% 37 32 11" D E 26” 4-1/2” 5-3/4” 3” 1-1/2” 1” 2” 2” 98 CDN070 70 14 94% 65 57 26” 6” 5-3/4” 3” 1-1/2” 1” 2” 2” 102 CDN100INLET 100 203-1/2" 94% 93 81 26” 7-1/4” 7” 3” 1-1/2” 1” 3” 3” 108 CDN120 120 24 94% 112 97 CONDENSATE 9-1/4" DRAIN Standard Features Optional Equipment 94% AFUE Efficiency Modulating Burner Direct-Spark Ignition Low-NOx Operation Field Convertible from Natural to LP Gas ASME Heat Exchanger 30 psi ASME Relief Valve Freeze Protection Vertical & Horizontal Direct-Vent PVC, CPVC, Polypropylene or SS Venting up to 100 feet Push-Button Digital Control Outdoor Temperature Reset (sensor included) Boiler Pump Control DHW Pump Control Expanded Polypropylene Jacket 10-Year Limited Warranty 5-Year Parts Warranty Concentric Vent Kit Sidewall Vent Termination 2” to 3” CPVC Vent Connection Kit Flow Switch Condensate Neutralization Kit Floor Stand Low Water Cut-off w/ Manual Reset and Test 11" 28 Flexibility is the SolutionTM What could be better than a high-efficiency boiler that saves space, saves money and helps resolve all your heating problems? How about one that’s lightweight and simple to install too! That’s the Solution™ boiler by Lochinvar®. From the highly efficient copper finned tube heat exchanger, to our own specially designed two-stage electronic control system, the Solution boiler offers these features and many more in models up to 260,000 Btu/hr. Plus, all Solution boilers are equipped with top water connections, a built-in draft hood, and are approved for installation on combustible floors. Copper Finned Tube Heat Transfer The heart of the Solution boiler is its copper finned-tube heat exchanger. With this unique gasketless design, we’ve combined the best of both worlds: cast iron headers for long-lasting durability, and a copper finned-tube heat exchanger for high efficiencies and fast heat transfer. The gasketless design reduces the risk of leaks or system failures that are common with conventional boilers. Plus, the unit’s low-mass design means that water gets heated quickly. Not only is heat up time nearly instantaneous with the Solution boiler, the energy consumption and operating costs are lower too, with a rating of 84% AFUE. Two-Stage Control The Solution boiler’s two-stage electronic temperature control with built-in outdoor reset provides flexibility and saves fuel by closely matching heat output to system demand. On colder days the boiler fires at full output, and in warmer conditions the Solution boiler reduces the setpoint heat output to save energy and reduce boiler cycling. During the majority of the heating season, less than full boiler output is required to satisfy the heat load. For this reason Lochinvar has developed a two-stage firing system. Two-stage firing - standard equipment on all Solution boilers, provides dramatic fuel savings by reducing the firing rate 50%. Two-stage firing is ideal for applications utilizing indoor/outdoor reset and is advantageous in systems where the Solution boiler is used with an Squire indirect water heater to produce domestic hot water. PVC/CPVC Vent Kit (optional) Vent up to 25’ out a sidewall or rooftop with PVC/CPVC (CB 45-135). Simple To Service The Solution boiler is as flexible and convenient as it is efficient and compact. For example, the heavy-duty stainless steel burners can easily be adapted for use with either natural or liquefied petroleum (LP) gas. What’s more, Solution boilers allow easy access to all major components for servicing. We even designed the heat exchanger to slide out the front of the boiler for faster maintenance, and we back it all up with our exclusive 20-year Limited Warranty. Built-In Piping Solutions Other boilers often require system piping upgrades which are cumbersome and expensive. The Solution boiler eliminates this problem with its built-in, performance loop. The loop maintains constant flow through the boiler when only a single zone of the system is calling for heat. This helps maintain peak system performance by keeping the copper heat transfer surface clean and operating at top efficiency. And the top water connections make replacements a snap by fitting into existing piping arrangements without additional elbows and connections. You can depend on Lochinvar, and you can depend on the Solution boiler to deliver the comfort, convenience, and reliability you need. For more information, call your Lochinvar dealer today. 29 Solution® Boiler Dimensions & Specifications Solution Heating Boiler Model Number CBN045 CBN075 CBN090 CBN135 CBN180 CBN215 CBN260 Input Max MBH AFUE 45 75 90 135 180 215 260 84.0% 84.0% 84.0% 84.0% 84.0% 84.0% 84.0% Dimensions & Specifications Heating Net AHRI Capacity Rating MBH MBH A B C D 37 62 75 112 149 178 216 32 54 65 97 130 155 188 Notes: Change ‘N’ to ‘L’ to denote L.P. gas models Net ratings based on piping and pick-up allowance of 1.15 29-1/2” 29-1/2” 29-1/2” 29-1/2” 29-1/2” 29-1/2” 29-1/2” 11-1/2” 15-1/2” 15-1/2” 19-1/2” 23-1/2” 26-1/2” 29-1/2” 21-1/2” 21-1/2” 21-1/2” 21-1/2” 21-1/2” 21-1/2” 21-1/2” Electrical Requirements: 120 VAC / 2 AMP Approved for indoor installation only Standard Features Optional Equipment ASME Copper Finned Tube Heat Exchanger Gasketless Heat Exchanger Design Built-In Performance Loop Top Water Connections 24 Volt Control System Self Diagnostic Ignition Control Terminal Strip Intermittent Electronic Ignition Two Stage Solid State Temperature Control Outdoor Reset with Outdoor Sensor System Sensor Two Stage Gas Valve w/ Built In Manual Shut-Off Domestic Hot Water Priority 160 PSI Working Pressure Pump Relay Automatic Reset High Limit ASME Pressure Relief Valve Temperature & Pressure Gauge Automatic Vent Damper Built-In Draft Diverter Stainless Steel Burners Loch-Heat Ceramic Tile Combustion Chamber CSA Design Certified for Installation on Combustible Floors CSA Design Certified for Alcove Installation 20 Year Limited Warranty on the Heat Exchanger (see warranty for details) 2-Year Parts Warranty Adjustable High Limit w/ Manual Reset Flow Switch Low Water Cut-Off Stack Frame Pump Delay w/ Freeze Protection MP2 Sequencer PVC/CPVC Venting Kit (CB 45-135) O2 Barrier 5-3/4” 7-3/4” 7-3/4” 9-3/4” 11-3/4” 13-1/4” 14-3/4” Gas Conn. Vent Size Ship Wt.(lbs) 1/2” 1/2” 1/2’ 1/2” 3/4” 3/4” 3/4” 4” 5” 5” 6” 7” 7” 8” 145 155 155 175 195 220 225 Water connections are 1-1/2” NPT Performance data based on manufacturer test results. Firing Control Systems M9 M7 Two Stage, Intermittent Spark Ignition California Code (CB215-260 only) 30 Buffer Tank/Hydraulic Separator What is a Buffer Tank/Hydraulic Separator? A Buffer Tank/Hydraulic Separator is designed to maximize the runtime and limit the on/off cycling of a boiler while separating the boiler flow from the system flow. In applications where the minimum system load is less than the minimum output of the boiler, there is a high propensity for the boiler to excessively cycle on and off due to the fact that the boiler is delivering more BTU’s than the system is requiring. In this case the Buffer Tank is designed to act as a battery for BTU’s. The system demand is met by using BTU’s that are already stored in the tank and thus delaying the boiler from initiating a heating cycle until a minimum run time can be accomplished. The Hydraulic Separator aspect of the tank is designed to de-couple the hydronic heating system flow from the boiler flow by acting as a “separator” so that the two independent flows do not affect one another. When the system flow is less than the minimum required boiler flow there will likely be erratic system delivery temperatures and excessive boiler cycling. These adverse affects can cause premature component failure, and in most cases, boiler efficiency will be adversely affected. When Should a Buffer Tank/Hydraulic Separator be Applied? A Buffer Tank/Hydraulic Separator can be applied to keep the boiler from short cycling in situations where the smallest building demand is less than the minimum rated output of the boiler and/or in situations where system flow is less than the flow required by the boiler. How is a Buffer Tank/Hydraulic Separator Sized? A Buffer Tank/Hydraulic Separator is sized to provide a minimum runtime for the boiler plant. Use the equation below to find the properly sized tank for your specific application. Tank connection diameters should be sized to meet the maximum flow requirements of the application. Buffer Tank Capacity = Desired Run Time x (Minimum Boiler Output – Minimum System Load) System rT x 8.33 x 60 • Desired Runtime- The Minimum period of time that the boiler should run before cycling off. • Lochinvar recommends a minimum boiler runtime of no less than 10 minutes. • Minimum Boiler Output- The amount of BTU’s that will be delivered at the minimum firing rate of the smallest boiler in the plant. • Minimum System Load- The absolute smallest heat demand of the building. • System Delta T- The difference between the system supply temperature and system return temperature. • 8.33- The weight of one gallon of water. • 60- The number of minutes in 1 hour Buffer Tank / Hydraulic Separator Dimensions and Specifications Model Gallon Number Capacity A B C D E BVU120 BVU200 BVU300 BVU400 BVU500 BVU750 BVU1000 120 200 300 400 500 750 1000 59-1/2” 89-1/2” 80” 80” 91” 104” 128” 32” 32” 40” 46” 46” 52” 52” 32” 32” 50” 56” 56” 62” 62” 43-3/4” 73-3/4” 57-1/2” 55” 66” 77” 101” Standard Ship. Conn. Size Wt. (lbs) 13-3/4” 13-3/4” 26-1/2” 29” 29” 31” 31” 3” NPT 3” NPT 4” Flange 6” Flange 6” Flange 6” Flange 6” Flange Notes: Custom Sizes and Configurations are Available, consult Factory for details. Additional Recirculation & Supply/Return Connections Sizes Available, consult Factory for details. Standard Features • • • • • • 31 ASME Sec. VIII U Stamp 125psi (Max. Allowable Working Pressure) Automatic Air Vent 5 Year Limited Warranty Pre-painted Jacket 2” HCFC Free Foam Insulation Optional Equipment • • • • • • • • • Temperature and Pressure Gauge Handhole Manway (300 gallons and larger) Custom Tapping Locations Custom Tapping Diameters Extra Tappings Custom Tank Sizes Flange or NPT Connections Relief Valve (Shipped Loose) 500 900 1,290 1,626 1,765 2,330 3,010 C Stainless Steel Buffer Tanks Hydronic Stainless Steel Buffer Tank Dimensions and Specifications 1” NPT VENT CONNECTION (SBT) 3/4 3/4” NPT VENT CONNECTION (RBT) *RBT Models only NPT Female Connection (Typical) Buffer Tank 3/4” DRAIN Model Number Gallon Supply/Return Capacity A B D E F G Conn. SBT030 SBT050 SBT080 SBT119 30 50 80 119 39-1/2” 47 69-1/2” 68-1/4” 20 24 24 28 28-3/4” 33-3/4” 55-3/4” 54-3/4” 20-1/4” 24-1/4” 35-1/4” 34-1/4” 11-3/4” 14-3/4” 14-3/4” 15” 7-3/4” 8-3/4” 8-3/4” 9” 1-1/2” NPT 1-1/2” NPT 2” NPT 2” NPT Ship Wt. (lbs) 70 120 153 198 Standard Features • • • • • • R-13.4 HCFC free foam insulation for minimal heat loss Textured, impact resistant polymer jacket Light-weight 316L stainless steel tank construction Bulbwell Drain and air vent connections 5 year tank warranty Hydronic Buffer Tank Dimensions and Specifications Model Gallon Number Capacity A B D E F G Supply/Return Conn. Ship Wt.(lbs) RBT030 30 34-1/2” 20-1/2” 24-1/4” 17-1/8” 9-1/2” 4” 1-1/2” NPT 70 RBT050 50 53-7/8” 20-1/2” 41-5/8” 25-3/4” 9-1/2” 3-3/4” 1-1/2” NPT 120 RBT080 80 58-3/8” 24” 46-1/4” 29” 11-3/4” 3-3/4” 2” NPT 153 RBT119 119 61-5/8” 29-1/2” 48-1/2” 30-1/8” 11-3/4” 3-3/4” 2” NPT 198 Standard Features • • • • • • Glass-lined Steel Tank High Density Foam Insulation Drain Valve Air Vent Connection Bulbwell 3-Year Tank Warranty 32 Stainless Steel Indirect A New Class of Water Heater • 17 Total Squire Models 6 Standard models from 30 to 119 Gallons 3 Dual Coil Models for Dual Source or High Capacity 65 to 119 Gallons 3 Electric Back-up Models 65 to 119 Gallons 5 Double Wall Models 40 to 119 Gallons • 316L Passivated Stainless Steel Tank • 316L High Capacity Stainless Steel Coil • Fully Welded Construction • HCFC Free Foam Insulation • Limited Lifetime Warranty Stainless Steel Indirect SIT Models Dimensions and Specifications SIT Models SIT***(DW) Double Wall Models SIT Models Dimensions and Specifications Domestic Model Water Number A B D G H I Conn. Coil Conn. Size Ship. Wt. (lbs) SIT030 SIT040(DW)* 39-1/2” 55-1/2” 20” 20” 32-1/4” 48-1/2” 21-3/4” 25-1/4” 8-1/4” 8-1/4” 3” 3” 1” 1” 1” 1” 79 105 SIT050(DW) SIT065(DW) SIT080(DW) SIT119(DW) 47” 60” 69-1/2” 68-1/4” 24” 24” 24” 28” 39-3/4” 52-1/4” 61-3/4” 60-1/4” 24-1/2” 28” 28” 31-3/4” 9-1/4” 9-1/4” 9-1/4” 9-1/4” 3-3/4” 3-1/4” 3-1/4” 3-1/4” 1” 1-1/2” 1-1/2” 1-1/2” 1” 1” 1” 1” 131 147 177 213 *SIT040(DW) “A” = 38-1/4” and “B” = 24”, All other model dimensions are same for single and double wall models Model Capacity Number (Gallons) SIT030 SIT040 SIT050 SIT065 SIT080 SIT119 27 40 52 67 82 113 Heat Source Water Volume (Gallons) Standby Loss (°F/Hr) Continuous Delivery (GPH) 1st Hour Delivery (Gallons) Min. Coil Load (Btu/Hr) Flow Rate (GPM) 1.1 1.6 1.7 1.9 2.1 3.2 1.5 0.9 0.9 0.7 0.6 0.5 160 181 209 263 266 349 183 208 255 327 347 459 99,000 115,000 133,000 154,000 160,000 199,999 14.0 14.0 14.0 14.0 14.0 14.0 Friction Loss (Ft. Hd.) 3.9 4.5 5.3 5.7 5.7 6.5 Performance data is based on I=B=R test results. All ratings are based on 180°F boiler water temperature. Ratings for Double Wall models are decreased. Please reference sales literature (SDW-02). Includes tank sensor for use with KNIGHT Heating Boiler. Optional thermostat available for use with other boiler models. 33 Stainless Steel Indirect SDT & SET Models Dimensions and Specifications FROM PANEL A D SET Models G TO PANEL H I FROM PANEL A COLD WATER INLET D SOLAR SENSOR WELL SDT Models Dimensions and Specifications G TO PANEL H Domestic I Model Water Number A B D E F G H I Conn. COLD WATER INLET SDT065 SDT080 SDT119 60” 69-1/4” 68” Model Capacity Number (Gallons) SDT065 SDT080 SDT119 24” 24” 28” 52-1/4” 61-3/4” 60-1/4” Solar Heat Source Water Volume (Gals.) 65.5 78.4 109.8 2.1 2.1 3.2 47-1/4” 33-3/4” 28” 9-1/4” 53-3/4” 40-1/4” 28” 9-1/4” 54-1/2” 37-1/2” 31-3/4” 9-1/4” Boiler Heat Standby Source Water Loss Volume (Gals.) (°F/Hr) 1.7 1.7 2.6 0.7 0.6 0.5 3-1/4” 3-1/4” 3-1/4” 1-1/2” 1-1/2” 1-1/2” Continuous 1st Hour Delivery Delivery (GPH) (Gallons) 174.6 174.6 250.2 204.7 207.1 300.5 Coil Connection Size Ship Wt. (lbs) 1” 1” 1” 158 188 224 Min. Coil Load (Btu/Hr) 128,000 128,000 181,000 Stainless Steel Indirect SDT Models SOLAR SENSOR WELL Flow Friction Rate Loss (GPM) (Ft. Hd.) 14.0 14.0 14.0 3.4 3.4 4.9 Performance data based on incoming cold water at 50°F and a Delta T of 77°F. Delivery ratings for boiler coil only. Includes tank sensor for use w/ KNIGHT Heating Boiler. SET Models Dimensions and Specifications Domestic Model Water Number A B D F H I Conn. SET065 SET080 SET119 60” 69-1/2” 68-1/4” 24” 24” 28” 52-1/4” 61-3/4” 60-1/4” 28” 28” 31-3/4” 9-1/4” 9-1/4” 9-1/4” 3-1/4” 3-1/4” 3-1/4” Solar Electric Heat Source Standby Continuous Model Capacity Water Volume Loss Delivery Number (Gallons) (Gallons) (°F/Hr) (GPH) SET065 SET080 SET119 67.0 80.9 112.4 1.9 2.1 3.2 0.7 0.6 0.5 23.9 23.9 23.9 1-1/2” 1-1/2” 1-1/2” Coil Conn. Size Ship Wt. (lbs) 1” 1” 1” 149 179 215 Electric 1st Hour Delivery (Gallons) 54.0 56.4 74.2 All SET models: 4500w 240v 1 phase. 34 System Another Space-Saving Idea Lochinvar’s technology not only makes our water heaters and boilers more efficient, they also have a smaller footprint. So they save space, as well as operating costs. And now there’s a way to get greater flexibility and reliability, save even more space, and get a system that’s perfectly matched to a facility–thanks to the Stack Frame from Lochinvar. Match Load And Capacity With this versatile frame, you can stack almost any combination of our ARMORTM, KNIGHT®, Copper-Fin®, Copper-Fin II®, and SolutionTM water heaters and boilers so you can achieve the perfect Btu/hr capacity for each application. For example, a facility needs a Copper-Fin II boiler with a total capacity of 1.6 million Btu/hr. Instead of installing an oversized CHN1802 unit or a smaller CHN1442 model, now you can combine two units – CHN0992 and CHN0652 models– to exactly match the facility’s needs. Plus, the total footprint of this combined system is just over 10 inches wider that the CHN0652 unit alone, making it smaller than either the CHN1802 or CHN1442 model. All thanks to the Lochinvar Stack Frame. No Assembly Required Lochinvar’s Stack Frame is fully factory assembled and shipped in one piece. The frame is welded using square steel tubing by certified welders. Each frame is designed and tested for each specific application. Added System Benefits This modular design provides two other important benefits. First, it allows for system turndown for greater efficiency when demand is lower. And second, it ensures against system failure by utilizing two independent but complimentary units. For residential and light commercial needs or commercial applications of up to 4 million Btu/hr the Stack Frame gives greater flexibility without a significant increase in stack size or overall system dimensions. Once you’ve determined a facility’s requirements and the exact models needed, utilize the charts provided to calculate total system dimensions. NOTE: Stack Frames are for indoor applications only. Our compact KNIGHT® requires even less space when stacked on a Stack Frame. 35 KNIGHT® Heating Boilers (Models 081-801) SolutionTM Boilers (Models 045-500) Knight® Wall Mount Boilers (Models 55-399) CadetTM Boilers (Models 40-120) A A A MODEL # PART # A* KB 081-211 MSF3043 90-1/2” KB 286-501 MSF3044 109” KB 601-801 MSF3052 109” C B C C B** C Wt. (lbs) 26” 26” 26” 26” 34” 43” 60 72 94 Note: Heater height is 33-1/4” KB 81-121 Heater height is 42-1/2” KB 286-501 MODEL # CB 045 CB 075 CB 090 CB 135 CB 180 CB 215 CB 260 CB 315 CB 360 CB 399 CB 500 PART # MSF 3034 MSF 3034 MSF 3034 MSF 3034 MSF 3034 MSF 3035 MSF 3035 MSF 3035 MSF 3035 MSF 3036 MSF 3036 A* 65-1/2” 65-1/2” 65-1/2” 65-1/2” 65-1/2” 65-1/2” 65-1/2” 65-1/2” 65-1/2” 65-1/2” 70-1/2” B** 36” 36” 36” 36” 36” 48” 48” 48” 48” 65” 65” C C BB C Wt. (lbs) 39” 73 39” 73 39” 73 39” 73 39” 73 39” 84 39” 84 39” 84 39” 84 39” 147 39” 147 System BB A A PART # A* B** C Wt. (lbs) MSF30018 60-1/4” 17-1/2” 36” 50 Note: Heater height is 29-1/2” (45 - 399) and 34-1/2” (500). Copper-Fin® Boilers (Models 0497-0747) MODEL # PART # A* B** C CB 0497 MSF3002 81-1/2” 51” 24-1/2” Wt. (lbs) 70 CB 0647 MSF3003 84-1/2” 70” 26” 128 CB 0747 MSF3003 84-1/2” 70” 26” Note: Heater Height is 33-1/4” (0497-0747) 128 A B C Copper-Fin II® Boilers (Models 0402-2072) MODEL # A PART # A* B** C Wt. (lbs) CH 0402 MSF3022 67-1/2” 59” 24-1/2” CH 0502 MSF3022 67-1/2” 59” 24-1/2” 83 83 CH 0652 MSF3023 67-1/2” 80” 24-1/2” 132 CH 0752 MSF3023 67-1/2” 80” 24-1/2” 132 CH 0992 MSF3007 80” 75” 36” 170 CH 1262 MSF3008 80” 95” 36” 214 CH 1442 MSF3008 80” 95” 36” 214 CH 1802 MSF3009 80” 119” 36” 251 CH 2072 MSF3009 80” 119” 36” 251 Note: Heater height is 31-1/2” (0402-0752) & 36” (0992-2072) B C * To vent connection ** Allow space for plumbing connections 36 Commercial Electric Compact Boilers Standard Features Optional Equipment • • • • • • • • • • Alarm Buzzes with Silencing Switch • Automatic Breaker • Flow Switch • ABB Fused Disconnect • Non-Fused Disconnect • Ground Fault Detection system • Low Temperature Switch • Kilowatt/Hour Meter • Flanged Water Connections • Amp Meter • Volt Meter • High Pressure limit switch • Control Panel door solenoid interlock • Low water cutoff-float type • BMS alarm interface • BMS remote set point control • BMS remote step control (remote enable) • BMS 120V interface to limit boiler power demand • BMS 24V interface to limit boiler power demand • Time clock • 304 stainless steel vessel & non ferrous trim • 3” connections • 4” connections • • • • • • • • • • • • • • • • ASME National Board Registered Pressure Vessel Heavy Duty Steel Boiler Vessel Housing 4” Fiberglass Insulation 3” NPT Inlet and Outlet Connection ASME Pressure Relief Valve Pressure Gauge with Cock Drain Valve Adjustable High Limit with Automatic Reset Adjustable High Limit with Manual Reset (units with more than 2 stages) Low Water Cut-Off Incoloy-Sheathed Elements Internal Branch Circuit Fusing Magnetic Contactors Main Supply Circuit Lugs 120 Volt Fused Control Transformer On/Off Switch with Pilot Light Manual Limit Toggle Switches (1 per step) Integeral Electric Control Panel with key locked door Electronic Multi-Stage Control Status Pilot Light for each Step Electric Digital Temperature Readout (except 1 & 2 step models) Listed by the Underwriters Laboratories 3 Year Limited Tank Warranty 1 Year Parts Warranty (See warranty for details) Commercial Electric Compact Boiler Dimensions & Specifications Components ** Inlet Pipe for 14” Flange or Flow Switch Option. Model Number BW*1-**C BW*2-**C BW*3-**C Max. Flow (gpm) 230 230 ¤ 230 4”/300 GPM is Optional ¤ 37 Connection Sizes (NPT) 3” 3” 3” Dia (In) 12” 16” 20” Vol (Gal) 22 36 56 A 52” 52” 52” Dimensions B 24” 28” 32” Ship C Wt.(lbs) 30” 600 34” 800 38” 1,100 ** Power Panel will be taller or wider for ABB Disconnect option. Consult factory. 1. Temperature Limit, Auto Reset 2. Temperature Limit, Manual Reset 3. Manual Limit Switches 4. Pilot Lights, Amber (Steps “On”) 5. PB Switches (Low Water Cutoff “Test”/”Reset”) 6. Toggle Switch (Control Power) 7. Pilot Light, Amber (Control Power “On”) 8. Pilot Light, Red (Low Water) 9. Temperature Setpoint / Control / Readout 10. Safety Relief Valve 11. Temperature & Pressure Gauges 12. Drain Valve (See warranty for details) Optional Equipment • • • • • • • • • • Alarm Buzzer w/silencing switch Automatic Breaker Flow Switch Non Fused Disconnect Fused Disconnect Ground Fault Detection System Low Temperature Switch Main Power Disconnect Manual Limit Toggle Switches (1 per step) Kilowatt/Hour Meter • • • • • • • • • • Amp Meter Volt Meter High Pressure limit switch Control Panel door solenoid interlock Low water cutoff-float type BMS alarm interface BMS remote set point control BMS remote step control (remote enable) BMS 120V interface to limit boiler power demand BMS 24V interface to limit boiler power demand • • • • • • Time clock 304 stainless steel vessel & non ferrous trim 3” connections 4” connections BACnet Communications Modbus Communications Commercial Electric Hot Water Boilers Standard Features • ASME National Board Registered Pressure Vessel • Heavy Duty Steel Boiler Vessel Housing • Full Sized Structural Steel Base • 3” Fiberglass Insulation • Flanged Inlet and Outlet Connection (above 3”) • ASME Pressure Relief Valve • Pressure Gauge with Cock • Full Port Drain Valve • Low Water Cut-Off with Manual Reset • Manual Limit Toggle Switches (one per step) • Adjustable High Limit with Automatic Reset • Adjustable High Limit with Manual Reset • Incoloy Sheathed Elements • Internal Branch Circuit Fusing • Magnetic Contactors • Main Supply Circuit Lugs • 120 Volt Fused Control Transformer • On/Off Switch with Pilot Light • Integral Electric Control Panel with Key Locked Door(s) • Electronic Multi-Stage Control • Status Pilot Light for each Step • Digital Electronic Readout • Listed by the Underwriters Laboratories • 3 Year Limited Tank Warranty / 1 Year Parts Warranty Commercial Electric Hot Water Boiler Dimensions & Specifications Note 1: Element removal clearance (R”) is equal to 2 times the element kW. Note 2: Optional equipment may change overall boiler dimensions. Please consult factory for dimensional information. Max Model Input Number kW BW*24 BW*24 BW*30 BW*36 BW*42 600 1076 1825 2246 3089 MBH Per Hour 2047 3673 6228 7665 10539 Max # of Elements 30 46 78 100 150 Connection Sizes (NPT) In/Out Drain 4” FLG 6” FLG 6” FLG 8” FLG 10” FLG 1-1/4” 1-1/2” 1-1/2” 2” 2” Max. Flow GPM 470 680 900 1,170 1,840 Tank Dims (In) 24x44 24x44 30x48 36x48 42x50 Data Dimensions Weight Vol (Inches) (lbs) (Gal) A B C D Ship Oper. 70 70 125 165 260 34” 34” 40” 46” 54” 40” 40” 50” 56” 76” 52” 56” 60” 62” 64” 51” 63” 75” 87” 77” 1,300 1,500 1,900 2,400 3,600 1,860 2,060 2,900 3,720 5,760 38 LTV Low Temperature Valves Ideal for Use with Copper-Fin, Copper-Fin II and Power-Fin Boilers When designing a boiler system with return water temperatures below 130°F, it is necessary to protect the boiler from flue gas condensation. All non-condensing boilers will develop operational problems if they are continually exposed to system return water temperatures below 130°F. Typical systems that require this protection are water source heat pump systems, in-floor radiant heat systems, greenhouse heating, soil heating, process operations and manufacturing operations. Additionally, heating systems that utilize nighttime setback, night/weekend shutdown or outdoor reset control strategies should incorporate low water temperature protection. To prevent low return water temperatures to the boiler and combat operational problems, the system should be piped in a primary secondary piping arrangement with a low temperature bypass. Manual bypass systems however are not the ideal solution due to varying flow rates and firing rate of the boiler. A better alternative is Lochinvar’s Low Temperature Valve, which is a self-contained automatic thermostatic 3-way valve that ensures temperatures entering the boiler remain above 140°F. LTV Valve Dimensions & Specifications 2-1/2” LTV Valve 2” LTV Valve 1-1/2” LTV Valve Over 55 GPM flow rate Part Number - 100172000 Note: Mounting flange Included with valves. Up to 55 GPM flow rate Part Number - 100172001 Up to 55 GPM flow rate Part Number - 100171919 TOP 11” 4” LTV Valve 7.94 Over 225 GPM flow rate Part Number - 100275912 TYPICAL PIPING A TOP 15.88 All boilers must use optional remote sensor. Minimum high limit setting is 205°F. Pump supplied by installer. B 11” TOP C 8.56 13.06 7.94 11” A 15.88 B FRONT 7.94 A 15.88 13.06 FRONT 8.56 13.06 C 8.56 B C 2” LTV Valve FRONT 2-1/2” LTV Valve 4” LTV Valve 39 1-1/2” LTV Valve 2-1/2” LTV Valve Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 | F: 615.547.1000 Lochinvar.com ASB-10M-7/17–Printed in U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Create Date : 2017:08:25 11:32:58-05:00 Creator : Adobe InDesign CC 2017 (Windows) Modify Date : 2017:08:25 11:39:56-05:00 Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Metadata Date : 2017:08:25 11:39:56-05:00 Creator Tool : Adobe InDesign CC 2017 (Windows) Instance ID : uuid:f9b38c15-a172-446e-95da-83719de0f653 Original Document ID : xmp.did:A5C3BA204BC6DF11B05481F170B234F7 Document ID : xmp.id:4dd48a8e-19bb-fc43-9c9f-060cb54f8317 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:16072fe1-39b0-1f4c-8ebb-68604df1951e Derived From Document ID : xmp.did:fad58c24-a39b-3148-852b-5861bddb3594 Derived From Original Document ID: xmp.did:A5C3BA204BC6DF11B05481F170B234F7 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Windows) History Changed : / History When : 2017:08:25 11:32:58-05:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 44EXIF Metadata provided by EXIF.tools