Rapid ATC 20 C.01.08.b Evaluation Safety Assessment Form

User Manual: ATC-20

Open the PDF directly: View PDF PDF.
Page Count: 1

ATC-20 Rapid Evaluation Safety Assessment Form
© Copyright 1995-07, Applied Technology Council.
Permission is granted for unlimited, non-exclusive, non-commercial use and distribution of ATC evaluation forms, provided that this Copyright Notice appears on all copies and the Applied
Technology Council name shall not be used in any advertising or publicity of Licensee product. Permission is further subject to the following conditions: (1) Licensee does not reprint, repackage
or offer this form for sale or license; and (2) no material gain or financial profit is to be made from any sale or license of this form. Placards may be used without restrictions for their intended use
as building postings. All rights not specifically granted to Licensee are herein reserved by ATC.
Minor/None
Inspection
Inspector ID:
Affiliation:
Evaluation
Posting
Further Actions Check the boxes below only if further actions are needed.
INSPECTED (Green placard)
Investigate the building for the conditions below and check the appropriate column. (excluding contents)
None
Estimated Building Damage
Areas inspected: Exterior only
Barricades needed in the following areas:
Detailed Evaluation recommended: Structural Geotechnical Other:
Exterior and interior
Observed Conditions: SevereModerate
0–1%
1–10%
10–30%
30–60%
60–100%
100%
Collapse, partial collapse, or building off foundation
Building or story leaning
Racking damage to walls, other structural damage
Chimney, parapet, or other falling hazard
Ground slope movement or cracking
RESTRICTED USE (Yellow placard) UNSAFE (Red placard)
Other (specify)
Other recommendations:
Comments:
Comments:
Record any use and entry restrictions exactly as written on placard:
Inspection date and time:
Choose a posting based on the evaluation and team judgment. Severe conditions endangering the overall building are grounds for
an Unsafe posting. Localized Severe and overall Moderate conditions may allow a Restricted Use posting. Post INSPECTED
placard at main entrance. Post RESTRICTED USE and UNSAFE placards at all entrances.
PMAM
Building Description Type of Construction
Building name:
Address:
Building contact/phone:
Approx. “Footprint area” (square feet):
Number of residential units:
Primary Occupancy
Wood frame
Steel frame
Tilt-up concrete
Concrete frame
Dwelling
Other residential
Public assembly
Emergency services
Concrete shear wall
Unreinforced masonry
Reinforced masonry
Other: _______________
Commercial
Offices
Industrial
Government
Historic
School
Other: _______________
Number of stories above ground: below ground:
Number of residential units not habitable:

Navigation menu