BX 12 Capio SLIM Brochure

User Manual: BX-12

Open the PDF directly: View PDF PDF.
Page Count: 4

Building on the history,
reducing the profile
Capio SLIM
Suture Capturing Device
Boston Scientific Corporation
One Boston Scientific Place
Natick, MA 01760-1537
www.bostonscientific.com/gynecology
Ordering Information
1.888.272.1001
©2013 Boston Scientific Corporation
or its affiliates. All rights reserved.
WH-125306-AB XM 1/13
The Capio SLIM Suture Capturing device features a reduced profile
to minimize the space required within the surgical field, easy
suture loading and a funnel shaped catch, designed for
consistent ease of use.
Since 1995, the Capio Device has provided
consistent suture placement in difficult
to access pelvic floor locations.
The
Capio SLIM
Suture Capturing Device
Capio SLIM Suture Capturing Device
The evolution continues…
36% Reduction in Head Width
Capio SLIM
Suture Capturing Device
Capio OPEN ACCESS
Suture Capturing Device
New “funnel” suture
dart catch design
Ergonomic Handle
Providing
3 Finger Grip
70% Reduction
in Shaft Diameter
Easy Suture
Dart Loading
The Capio Suture Capturing Device
debuts, revolutionizing the field of
urogynecology.
The Capio Device is used with
Repliform Graft, offering another
treatment option.
The Capio Device is used with
Xenform Graft, offering more
material options for prolapse repair.
1995 1999 2006
Fixation Device Comparison
Shaft Diameter
(mm)
Head Width
(mm)
Device Weight
(g)
Carrier Diameter
(mm)
Capio OPEN ACCESS
Suture Capturing Device** 10.1 9.8 45.4 1.2
Capio SLIM
Suture Capturing Device* 3.0 6.3 38.2 1.2
Digitex
Suture Delivery System* 9.5 9.6 133.3 2.1
FiXT
Suturing Device* 4.8 6.9 121.1 2.2
Comparison of Device Heads
Capio SLIM
Suture Capturing Device
Digitex
Suture Delivery System
FiXT
Suturing Device
with the Capio SLIM Suture Capturing Device.
Figure 2: Fixation Device Comparison illustrates the device profile differences amongst these fixation devices. The Capio SLIM Suture Capturing
Device has the smallest device profile based on the following measurements: shaft diameter, head width and device weight.
*Measurements were recorded using one (1) of each device. Data on file at Boston Scientific.
** Head width and device weight values are an average of five (5) device measurement recordings. Shaft diameter values are an average of fifteen (15) device measurement recordings.
Data on file at Boston Scientific.
Building on the history and reducing the
profile, the Capio SLIM Suture Capturing
Device features one of the smallest device
profiles and suture dart carrier diameter while
keeping the same bite depth as the current
Capio Open Access Suturing Device.
Figure 1: Comparison of Device Heads illustrates the difference in carrier
diameter amongst these fixation devices. The Capio SLIM Suture Capturing
Device carrier diameter is 45% less than the FIXT Suturing Device and
43% less than the Digitex Suture Delivery System.
The Capio Device is used with the
Uphold System, one of the smallest mesh
footprints for pelvic floor reconstruction.
The Capio Device remains
“the foundation” of Pelvic
Floor Reconstruction.
Capio Slim: the
evolution continues.
2008 2011 2012
Capio SLIM Suture Capturing Device
Order
Number Description Unit
M0068318250 Capio SLIM Suture Capturing Device bx 1
M0068318261 Capio SLIM Suture Capturing Device bx 5
Capio Sutures
Order
Number Description Size Unit
M0068331131Non-absorbable, coated braided polyester, double
armed with TC tapercut needle (dart), 48" 0 bx 12
M0068331231Non-absorbable, polypropylene monofilament,
double armed with TC tapercut needle (dart), 48" 0 bx 12
M0068332131Absorbable, coated braided PGA, double
armed with TC tapercut needle (dart), 48" 0 bx 12
M0068331141
Non-absorbable, coated braided polyester, double
armed with TC tapercut needle (dart) and a T 26mm
1/2 circle taper needle, 36"
0 bx 12
M0068331241
Non-absorbable, polypropylene monofilament,
double armed with TC tapercut needle (dart) and a
T 26mm 1/2 circle taper needle, 36"
0 bx 12
M0068331371
Monodek Absorbable, monofilament PDO, double
armed with TC tapercut needle (dart) and a T 26mm
1/2 circle taper needle, 48"
0 bx 12
Your Pelvic Floor Reconstructive Tool to
Meet a Variety of Your Algorithm Needs:
- Native Tissue Repair
- Biologic Graft Augmentation
- Synthetic Mesh And More…
Repliform Tissue Regeneration Matrix complies with U.S. Regulations in 21 CFR part 1270 and 1271
Human Tissue for Transplantation.
Capio, Xenform and Uphold are registered trademarks of Boston Scientific Corporation or its affiliates.
All other trademarks are property of their respective owners.
Caution: Federal Law (USA) restricts these devices to sale by or on the order of a physician.
Refer to package insert provided with these products for complete Indications for Use, Contraindications,
Warnings, Precautions, Adverse Events, and Instructions prior to using these products.
Data on file. Bench test results may not necessarily be indicative of clinical performance. Results from
case studies are not predictive of results in other cases. Results in other cases may vary.
Boston Scientific Corporation
One Boston Scientific Place
Natick, MA 01760-1537
www.bostonscientific.com/gynecology
Ordering Information
1.888.272.1001
©2013 Boston Scientific Corporation
or its affiliates. All rights reserved.
WH-125306-AB XM 1/13

Navigation menu