Section 009 DOC ACTIVE KGL 100, 40 T Cleveland Range 100 Specsheet
User Manual: KGL-100, KGL-40-T
Open the PDF directly: View PDF .
Page Count: 2
Download | ![]() |
Open PDF In Browser | View PDF |
Project ________________________________ ™ Cleveland Item __________________________________ GAS KETTLES Approval _______________________________ Quantity _______________________________ FCSI Section ____________________________ Date __________________________________ LEG TYPE, GAS-FIRED KETTLES STATIONARY, 2⁄3 STEAM JACKETED “SPLASH PROOF SERIES” 40, 60, 80 or 100 GALLONS (150, 225, 300 or 337 LITERS) MODELS: KGL-40 KGL-80 KGL-60 KGL-100 Cleveland Standard Features I High efficiency Power Burner Heating System (62% to 65% efficiency) I Fast Heat-up and Recovery Time, 140M BTU’s on 40 gallon models, 190M BTU’s on 60 gallon and larger I Insulated Heat Exchanger I Automatic Ignition System I Steam jacket permanently filled with treated, distilled water. Venting and/or refilling not required I Solid State Controls, for Temperature and Low Water Safety, in a plug-in Control Module I Control Panel includes: I Precise, consistent temperature control: less than ± 1°C variance (ideal for simmering). I L.E.D. Indicators for Heat Cycle and Low Water I Warning. I Power “on/off” Switch I I Front mounted combination Pressure/Vacuum Gauge I Type 304 Stainless Steel with #4 finish on kettle and supports I 2˝ diameter Tangent Draw-Off Valve with Drain Strainer I Support Legs with level adjustable feet, flanged for floor Short Form Specifications bolting I Spring-assisted, hinged, rotatable, domed Stainless Shall be CLEVELAND, Gas-fired Stationary Kettle, Model KGL-_____ ; _____ gallons. 2⁄3 Steam Jacketed, Power Burner Heating System, Insulated Heat Exchanger, 50 psi Steam Jacket Rating. Infinite Variable Temperature Control, L.E.D. indicators for Heat Cycle and Low Water Warning, spring-assisted Cover, 2˝ Tangent Draw-off Valve with Drain Strainer, Automatic Ignition System. Steel Cover I 50 PSI Steam Jacket Rating and Safety valve I Standard voltage is 115 volts, 60 Hz, single-phase, supplied with cord and plug I Standard for natural gas operation I Faucet Mounting Bracket (FBK) I Typical approvals include AGA, CSA, CE, NSF and ASME Options & Accessories Ë Type 316 Stainless Steel Kettle Liner for high acid food products (316) Ë Hot and Cold Water Faucet with Swing Spout (DPK) Ë Cooking Baskets and Tri-Basket Supports (BS and TBS) Ë Drain Strainers (DS-) Ë 3" diameter Tangent Draw-off Valve with Drain Strainer (TD3) Ë Kettle Accessory Kit (KAK) includes: Ë Clean-up Brush(CB) Ë 36” Kettle Paddle (KP) Ë 36” Kettle Whip(KW) Ë 36” Kettle Brush (KB) Ë Draw-off Brush (DB) Ë 24 oz. Ladle (KL) Ë Automatic Water Meter (GMF or LMF) Ë Measuring Strip (MS) Ë Option for Propane Gas operation Ë Correctional Package Ë Heat Deflector Shield (HS001) SECT. IX PAGE 9 0609 1333 East 179 St., Tel: 1-216-481-4900 Web Site: www.ClevelandRange.com Cleveland, Ohio, U.S.A. 44110 Fax: 1-216-481-3782 Email: Steam@ClevelandRange.com K J A H 3 (77 mm) 4" (102 mm) M N O B 4 7/8" 124 Ø mm 7/16" (11 mm) Ø 3 HOLES ON 3 1/8" (80 mm) Ø B.C.D. L 120º TYP C 1 5/8" (42 mm) Ø 1" (25 mm) MAX. ADJUSTMENT FLANGED FOOT DETAIL FLOOR DRAIN 12" (305 mm) WIDE x 12" (305 mm) LONG VALVE OPENING P 9/16" 14 mm S 3" (77 mm) MINIMUM CLEARANCE T (I.D.) 75º G (COVER OPEN) H C D 4" (102 mm) RECOMMENDED RECOMMENDED FLOOR SLOPE 1" (26 mm) per 4' (1220 mm) F PIPE DRAIN RECOMMENDED min. valve size plus 1" (26 mm) E UNIT SHOWN WITH OPTIONAL 2" TANGENT DRAW-OFF VALVE, SPRING ASSIST COVER AND HOT & COLD WATER FAUCET. DIMENSIONS GALS./ LITERS 40 150 60 225 80 300 100 375 IN mm IN mm IN mm IN mm CAPACITIES: (in 8 oz. servings, other sizes may be calculated) 40 Gallon / 150 liters . . . 640 servings 60 Gallon / 225 liters . . . 960 servings 80 Gallon / 300 liters . . . 1280 servings 100 Gallon / 375 liters . . . 1600 servings A B C D 35 1/8 893 38 1/4 972 41 5/8 1058 44 1118 37 940 39 991 42 3/8 1077 43 1/2 1105 32 1/4 820 34 1/4 870 35 1/2 902 36 1/2 928 40 1/2 1029 43 1/2 1105 45 1/2 1156 47 1/2 1207 E F G H 9 1/4 16 71 1/2 235 407 1817 8 3/4 14 1/4 75 223 362 1905 8 3/4 15 1/2 79 223 394 2007 8 3/4 15 1/2 83 1/2 22.3 394 2121 9 9/16 243 8 15/16 228 9 1/4 235 9 1/8 232 J GAS NATURAL Piping: 3⁄4˝ N.P.T. Supply pressure: 4.00˝ W.C. minimum 14.00˝ W.C. maximum PROPANE Piping: 3⁄4˝ N.P.T. Supply pressure: 4.00˝ W.C. minimum 14.00˝ W.C. maximum K L 17 3/4 25 15/16 10 3/8 451 659 264 19 1/8 29 5/16 10 3/8 486 745 264 20 3/4 32 1/4 10 3/8 528 820 264 21 7/8 34 5/8 10 3/8 556 880 264 M N O 18 5/8 474 18 5/8 474 18 5/8 474 18 5/8 474 26 7/8 683 27 7/8 709 29 5/8 753 31 1/4 794 28 1/2 724 30 1/4 769 31 1/2 801 32 1/2 826 ELECTRIC B.T.U. RATING 40 gal. 140,000 60 gal. 80 gal. 190,000 100 gal. Manufacturer must be notified if unit will be operated above 2,000 ft. altitude. 120V-1 Phase, 60 Hz, 10 amps P S T I.D. 4 5/8 24 1/2 26 118 648 661 5 1/4 27 29 1/2 134 686 750 6 5/8 29 33 169 737 839 7 1/2 30 1/2 35 1/2 191 775 902 WATER H C ⁄2˝ dia. Soft Copper Tubing (each) 1 H C When ordered with optional faucet. CLEARANCE RIGHT = 3˝ LEFT = 3˝ REAR = 3˝ Allow 6˝ space minimum from rear and sides when located near combustible walls. 12" recommended on right side for service NOTES: Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Installation of backflow preventers, vacuum breakers and other specific coder requirements is the responsibility of the owner and installer. Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL and others. SECT. IX PAGE 10 0609 Litho in U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Page Mode : UseThumbs XMP Toolkit : 3.1-701 Modify Date : 2009:05:26 14:58:57-04:00 Create Date : 2009:05:26 14:56:38-04:00 Metadata Date : 2009:05:26 14:58:57-04:00 Creator Tool : QuarkXPress(R) 7.3 Format : application/pdf Title : Section 009 DOC ACTIVE.qxd Document ID : uuid:f15d0eae-4a26-11de-98fc-00145116cba2 Instance ID : uuid:43f8e2b2-4a27-11de-98fc-00145116cba2 Producer : QuarkXPress(R) 7.3 Has XFA : No Page Count : 2 Page Layout : SinglePage Creator : QuarkXPress(R) 7.3EXIF Metadata provided by EXIF.tools