Disc TN860 3 Site Monitor Codan CI MC 0 And Controller Discontinued
User Manual: Discontinued Products | LMR & HF Radio | Codan Radio
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
DANIELS TECHNICAL NOTES TM ELECTRONICS LTD. MT-3 Radio Systems The CI-SITE/MC-0 Site Monitor and Controller is a low current, high reliability site monitor capable of operating at extreme temperatures in remote locations. The Site Monitor and Controller has eight analog inputs for monitoring various voltage levels, eight digital inputs for monitoring logic levels, and eight “open drain” outputs for activating relays or alarms. The Site Monitor and Controller can be set up in a limited configuration as a stand-alone unit at a repeater site and can be used to send alarms tones over the air. The Site Monitor and Controller can also be configured as a Gateway-Slave configuration where the Gateway is located at a base station and is connected to a computer running the Site VIEW application software (CI-SITE/MC-9). The Gateway communicates with the Slave units located at the remote repeater sites using FFSK format over the RF links (the Site Monitor and Controller has an FFSK modem built in). This also allows the Slave units to be remotely reprogrammed, controlled, and monitored from the Gateway location. The Site Monitor and Controller can also be used in a Hot / Cold Standby System. The Site Monitor and Controller can monitor alarm and voltage inputs on the Primary system and switch over radio communications to the Secondary system automatically on any alarm or low voltage condition. The Site Monitor and Controller provides the following features: 19” rack mountable chasis - chasis is capable of holding two Site Monitor and Controllers in 1 RU Built-in FFSK Modem - capable of 1200/2400 baud over a Daniels radio link with pre/de-emphasis or flat audio Low current consumption - average current draw of 65 mA when active, - average current draw of 15 mA when in standby Eight analog inputs - individual analog inputs can be configured as contact closures, switches, open collector or variable voltage inputs - individual channel hold timers Eight digital inputs - individual digital inputs can be configured with 0 - 2.56 V, 0 - 5.0 V, 0 - 25 V and 4 - 20 mA user defined ranges up to 100 V. - individual channel low and channel high set point triggers with individual hold timers - 10 bit A/D Eight outputs - “open drain” FET outputs, voltage switching up to 50 Vdc @ 150 mA current sink - programmable pulse or latching outputs Optional temperature sensors - span of -55 °C to +125 °C (-67 °F to +257 °F) 43 Erie Street Victoria, B.C. Canada V8V 1P8 TN860 Rev 3-0-0 Jan 07 Toll Free Phone: Fax: Canada & U.S.A. 1-800-664-4066 1-877-750-0004 International Phone: 250-382-8268 Fax: 250-382-6139 © Copyright 2007 Daniels Electronics Ltd. All rights reserved. e-mail: web: Internet sales@danelec.com www.danelec.com Page 1 of 2 T h i s p r o d u c t h a s b e e n d i s c o n t i n u e d a n d i s n o l o n g e r m a n u f a c t u r e d b y D a n i e l s E l e c t r o n i c s L td . TN860 CI-SITE/MC-0 Site Monitor and Controller DANIELS TECHNICAL NOTES TM MT-3 Radio Systems ELECTRONICS LTD. Examples of Site Monitor and Controller Capabilities: Input Monitoring Outside and Inside Temperatures High VSWR Alarms AC Power Fail Alarms Transmitter Forward and Reverse Power Solar Panel, Battery and Regulated Voltages Door Alarms Output Control Redundant System Enable Light Activation Generator Start Directional Antenna Control Installation: Connect the Daniels Electronics subrack with A-PNL-AUX96-3 auxiliary connector to the Site Monitor and Controller as shown in the diagram below. The diagram below shows a Site Monitor and Controller connected to a Daniels Repeater with an AC-3E audio control card. CI-SITE/MC-0 SITE MONITOR AND CONTROLLER P1 (A-PNL-AUX96-3 CONTROL CONNECTOR) DANIELS RADIO EQUIPMENT (SPARE 5)AUX_1_AUDIO O/P1 (SPARE 6)AUX_1_AUDIO 0/P2 (SPARE 1) AUX_1_AUDIO I/P1 (SPARE 2) AUX_1_AUDIO I/P2 (ALARM 6) AUX PTTA I/P GROUND (ALARM 2) COR A GROUND 13.8V 9.5V RXA SIG STRENGTH REVERSE ALARM OUTPUT FORWARD ALARM OUTPUT 13.8V GROUND J3-5 RX+ J3-6 RX- J3-1 TX+ J3-2 TX- J3-14 PTT OUTPUT J4-2 GROUND J3-10 COR INPUT A J4-3 COR INPUT B J4-6 ANALOG INPUT 1 J4-7 ANALOG INPUT 2 J5-7 ANALOG INPUT 3 J5-3 DIGITAL INPUT 1 J5-2 DIGITAL INPUT 2 J4-5 +13.8V INPUT J4-1 GROUND Jumpers Required: AC-3E: JU48A, Remove JU51 43 Erie Street Victoria, B.C. Canada V8V 1P8 Page 2 of 2 Toll Free Phone: Fax: Canada & U.S.A. 1-800-664-4066 1-877-750-0004 International Phone: 250-382-8268 Fax: 250-382-6139 © Copyright 2007 Daniels Electronics Ltd. All rights reserved. e-mail: web: Internet sales@danelec.com www.danelec.com TN860 Rev 3-0-0 Jan 07 T h i s p r o d u c t h a s b e e n d i s c o n t i n u e d a n d i s n o l o n g e r m a n u f a c t u r e d b y D a n i e l s E l e c t r o n i c s L td . TN860 CI-SITE/MC-0 Site Monitor and Controller
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2006:12:27 15:21:47-08:00 Modify Date : 2006:12:27 15:21:47-08:00 Page Count : 2 Creation Date : 2006:12:27 23:21:47Z Mod Date : 2006:12:27 23:21:47Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : plunness Metadata Date : 2006:12:27 23:21:47Z Creator : plunness Title : Disc TN860-3 Site Monitor.qxdEXIF Metadata provided by EXIF.tools