DCN Next Generation 2.40.1586 NG Release Note En US 11907957259
User Manual: DCN-NG
Open the PDF directly: View PDF .
Page Count: 26
Download | |
Open PDF In Browser | View PDF |
DCN Next Generation 4.10 Release Notes en Release Notes DCN Next Generation Release Notes en | 2 DCN Next Generation Release 4.10 Table of Contents 1 2 3 4 5 6 7 8 This release Contains ........................................................................................................ 2 Improved and added Functionality .................................................................................. 3 Release Compatibility Restrictions .................................................................................. 7 Software, Firmware & FPGA versions ............................................................................. 8 Additional Information to the DCN Manuals and Help Files ........................................ 10 Additional Information to the Integrus Manual ............................................................. 17 Trouble Shootings and known issues ........................................................................... 19 Appendix: Guaranteed Rectangular Footprints ............................................................ 25 1 This release Contains The following versions are part of this release: Product version DCN-SW 4.10 DCN-SWSMV 4.10 DCN-SWSACC 4.10 DCN-SWWA 1.01 DCN-DLT (CCU2) 4.10 DCN-CCU2 4.10 HdCameraControl 4.10 DCN-DLT (CCU, NCO) 3.10 DCN-CCU 3.10 Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes 2 en | 3 Improved and added Functionality Release 4.10 Release Date 2013-04-17 4.03 2012-07-15 4.02 2012-04-16 Release Comments Improvements Additions • Start/Stop Meeting and Session and Microphone Management control via API (DCN-SWAPI) including demonstrator application with source code. • Control of the IDesk outgoing channel using DCN Operator Application (requires DCN-SWSI license). • DCN-SW font colour below icons on layout can be changed. • DCN-SW Meeting can be copied (including all settings) using Configuration Application and API. • Demonstrator application including source code for DCNSWSMD XML streaming meeting data. • HD Camera Control via DCN-SWSMD streaming meeting data. • DCN-SW added Czech language to the GUI. Czech language has to be copied manually, please refer to the Tools\Language\ directory. • Extended the explanation about the TCP connection in Open Interface description. • DCN-SWWA Webcast application added. Only English Userface. Only audio-channel/language only. Fixes • DCN-SWSMD information regarding microphone on off. • DCN-SWSMD information empty when session name and description are identical. • Stopping an Operator-control session does not clear request list. • DCN-MR wave form and audio sometimes not in sync. • DCN-SW not all GUI texts fit. • DCN-SWSMV Reset microphone sensitivity ALL MICROPHONES. • DCN-CCU2 can cause acoustic feedback when powered up in Insertion mode. • DCN-SW added Slovenian language to GUI. Made Japanese helpfile part of the installer. Added Thai, Polish and Finnish language to the installer. • DCN-SWSMD Participant is made absent when Chairman speaks in Operator with response mode. • Quorum shows strange behaviour with ID-cards and Secret voting. • Performance and stability improvements on DCN SW Server and Operator Control • Delegate names are not shown in speakerlist when using access control for voting only. Fixes • DCN-SW Operator Application can cause a fault pop up upon user login and start session. • DCN-SW Configurator Application can cause a fault pop up when a document will be inserted with a file name that is too long. • DCN-SW Printing Application will not start up in Spanish, Catalan, Portuguese and Polish. Fixes • Inserting or withdrawing of ID-cards could lead to fault pop up. Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes Release 4.01 Release Date 2012-03-01 4.00 2011-12-02 3.10 2011-07-26 3.03 V2 2011-01-12 3.03 2010-11-12 3.01 2010-07-01 3.00 2010-05-26 2.82 2010-01-26 en | 4 Release Comments Fixes • Auto-relay is always activated when the B-output channel is selected (Using DCN-SW with DCN-SWSI). • DCN-CCU2 replaces DCN-CCU, DCN-WCCU and DCN-NCO • DCN-CCUB2 replaces DCN-CCUB Additions • Simultaneous Interpretation DCN-SWSI added • Usher call and speak slowly requests support DCN-SWMD • DCN-SW GUI languages: de, ca, en, es, fr, hu, it, jp, ko, lt, nl, no, pt, ru, sv, zh-chs • DCN-SW help files languages: de, en, es, fr, it, nl, zh-chs Improvements • Seat assignment and seat definition improved • DCN-SWSACC indicates when DCN-SWSACC licenses is missing. Fixes • DCN-SWSACC upload does not work Fixes • DCN-SWSMD does not always send individual voting and group results Improvements • The DCN-SW print application can be used on a client PC. (see chapter 4 how to setup) Fixes • Vote result view translated to local languages • Microphone cannot be controlled from the synoptic layout in operator with request list microphone mode • Update of Spanish translation in LBB4190 and DCN-CON Improvements Additions • DCN-SWSACC Standalone Automatic Camera Control which replaces LBB 4162/00 • All DCN applications (LBB4190 excluded) are Windows 7 and Windows Vista compatible (Home Premium and above both 32 and 64 bits). LBB 4190 is compatible with XP Professional 32 bits version only. • Japanese and Dutch GUI language added to DCN-MR • Norwegian GUI language added to DCN-SW Fixes • Lithuanian GUI language added to DCN-SW • Vote result printout translated to local languages • Maximum number of Open microphone in France GUI language cannot be set to 3 and 4 • DCN-IDESK startup behavior is improved. • DCN-SWSMD The Participant container in Discussion Activity type SpecialEquipmentListUpdated contains Participant data in stead of seat data. Improvements and additions • Improved updating of Interpreter’s Booth Desk settings in the Open Interface • DCN calculation V5.04 update Fixes • Auto-relay may not operate as expected when B output toggle is activated in LBB 4172/00 Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes Release 2.81 Release Date 2009-11-20 2.80 2009-10-19 2.70 2009-07-17 2.68 2009-05-06 en | 5 Release Comments Improvements and additions • New background images are added to the DVD for use in DCNSW and DCN-SWSMV Fixes • LBB 4172/00 does not work in all languages except English • Location of texts “Speakers” and “Requests” on Concentus display are fixed for Simplified Chinese. • DCN-IDESK sometimes shows a loudspeaker symbol before the quality indicators after leaving the installation menu. (solved in DCN-IDESK with SW ≥1.41.xxxx) Improvements and additions • Support for DCN-IDENC in LBB 4181 nd • B toggle (2 B output) on interpreter desk (only supported for DCN-IDESK SW ≥ 1.40.xxxx). • Channel overview on DCN-IDESK automatically returns after 1 second when switching on the microphone. • Catalan GUI language added to DCN-SW • The state (enabled or disabled) of Audio Expanders audio inputs are restored after configuration changes • Participantupdate activity is send after start and stop meeting in the DCN-SWSMD xml stream. • Fixes • The audio routing of the system might not work due to optical network disturbances. • Hyperlink to driver for DCN-IDENC fixed DCN MR • Recording uses the default windows recording settings. • Recording input level is not automatically set to 100%. • Improvement of foot pedal activation. • DCN-MR restarts automatically after changing the user interface language. Improvements and additions • DCN-SWIND Individual Channels. • DCN-SW supports Multi-CCU up to 1500 seats. • DCN-SW GUI Languages: JP, KO, TH, ZH-s. • DCN-SW is extended with: DCN-SWAT Conference Software Attendance and Access DCN-SWID Conference Software ID Card Encoding DCN-SWAPI Conference Software API DCN-SWSMD Conference Softw. Streaming Meeting Data • Major improvements of the stability of the optical network. Fixes • Speech timers do not continue after the chairman has stopped speaking. • Synoptic view in LBB4171/00 shows several red crosses after restarting the CCU. • External contact cannot be defined in non English versions of LBB 4175/00. • Unknow hardware errors in LBB 4190/00 software log file. • DCN-SW in Russian language reports an error in the Seats view. Fixes • The system becomes instable after several start stop meeting actions. • Integrus transmitter to much noise in channels 4, 5, 6 and 7 in Premium Stereo mode. Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes Release 2.67 Release Date 2009-04-01 Release Comments • • • • • • • 2.64 2008-12-15 • • 2.63 2008-11-27 • 2.62 2008-10-28 • • • • • • • • • • 2.60 2008-08-06 2.56 2008-04-08 2.55 2008-03-31 • 2.54 2.53 2008-03-10 2008-03-03 • • 2.52 2008-02-22 • 2.51 2008-01-28 • • 2.50 2007-12-17 en | 6 • • • • • • Bosch Security Systems| 2013-04-26 Added GUI language in DCN-SW DE, FI, FR, IT, NL, RU, SE. DCN-SW delegate view. Concentus language selection synchronized with CCU. Fix DCN-SMSMV vote application does not work in Russian language. Improvement LBB 4180/00 delegate group selection. Improved of NCO communication and camera control. Improvement Open interface assign Interpreter desks. DCN-MR GUI language added: ES, FR, IT, KO, PT, RU, TH and ZH. Improved audio quality on delegate units headphones. DE, ES, FR, IT, JA, KO, PT, RU, TH and ZH version of DCNMR manuals. Improvement of Integrus transmitter startup behavior. Automatic standby of Integrus transmitter removed. Added option to disable assignment of a new address when pressing the button of a unit with a double address (dipswitch S600-2 of CCU). The default voting representation in Video Client is changed to Yes, No, Abstain and DNPV. Upgraded performance of Voice Activation algorithm. Solved occasional problems with start up of Integrus transmitter. DCN-MR added. Support for DCN-SW. DCN-MR added. Improvement of Multi CCU. Improvement of Multi PC (LBB4189). Improvement of behavior of an Integrus transmitter when connected to a DCN Next Generation or DCN wireless system. DDE data not correct when seat or card-code are empty in the database Notification of speak slow button release fixed Improvement of Video Client (LBB4184) - in certain circumstances when video client was used, the voting results disappeared. Improvement of CCU. In single CCU mode, the “No NCO” message will not appear anymore. The maximum number of devices that you can connect to the optical network of the central control unit is increased to 18. Insertion mode is changed and has now only effect on the delegate loudspeakers and interpreter floor channel. PA output signal is excluded from the insertion mode. A noise gate is added to the insertion and mix minus mode. Available via Open Interface: - Booth desk configuration - De-init CRC-check default on for ID-Cards Channel quality overview in DCN-IDESK Improved representation and print outs for voting in combination with attendance/quorum Bugs solved, amongst others: - reduced chance of the message “No NCO” - switch off of DCN trunks in case audio expander is reset to defaults DCN Next Generation Release Notes Release 2.41 Release Date 2007-08-01 2.40 2007-06-20 2.12 2006-02-05 • 2.10 2005-10-10 • • Release Comments • • • • • 2.01 2005-05-30 • • • 2.00 2005-03-03 • • 1.12 2004-12-10 • 1.11 2004-07-23 • 1.10 2004-06-25 • • − − • 1.00 2004-06-15 en | 7 • Downloading improved for DCN-CCUB DCN-DLT bug solved for non English operating systems Support for Multi CCU applications. Improvements: - voting print results improved - muting of the floor System bug solved: At room temperature higher than 25 degree’s system reboot may not work properly. Concentus bug solved: Audio may contain hearable ticks. Support for new Discussion units, Cobranet Interface and Digital Audio expander. System bug solved: system reset of units after connecting new units to a trunk Multi PC improved CCU: solved bug. The display shows ‘starting’ and the navigation doesn’t work. Control PC bug solved. After deleting two or more consecutive records from delegate database, individual voting results may not be correct (This did not affect total results.) Concentus and Flush mounted units added. Software function added: Microphone Management, Synoptic Control, Intercom, Parliamentary Voting, Multi Voting, Attendance Registration, Delegate Database, ID cared encoder, Message Distribution, Text/Status Display, Video Display, Camera Control and Standalone Camera Control. Interpreter desk: solved bug in audio switching from pre-select to floor Interpreter desk: solved bug in audio switching behavior of preselects (incoming channels) Audio Expander: increased output range to 30 dB Interpreter desk: improved response time of actions related with microphone button default outgoing B is equal to outgoing A Open Interface: compatibility restored with previous versions of Open Interface. Initial version 3 Release Compatibility Restrictions The following versions are incompatible with this release: Product Hw FPGA DCN-CCU2 na DCN-CCU <1.07 DCN-CCU in multi CCU mode <5.0 <2.17 DCN-NCO LBB 4120/00 Interpreter desk <1.2 Toggle in DCN-IDESK The following applications are compatible with this release: Product Hw FPGA DCN-SW 4.00.3959 DCN-SWSMV DCN-SWSACC DCN-MR Bosch Security Systems| 2013-04-26 SW na -- FW <4.10 <3.10 -- -<1.40.xxxx -- SW 4.10 4.10 4.10 2.0 FW 4.10.4806 DCN Next Generation Release Notes Product Download and License Tool DCN-SWWA HdCameraControl Optical devices en | 8 Hw FPGA SW 4.10 1.01 4.10 FW 5.02 DCN-SWSMV: exporting voting results to PowerPoint is only supported for PowerPoint 2003. DCN-SWWA requires DCN-CCU(B)2. Wireless Units: New firmware is developed for the DCN Wireless units to operate with the DCN-CCU2 (e.g. encryption functionality). This firmware can be uploaded using the Download and License Tool (DLT) and the Upgrade Toolkit (DCN-UPTK). This firmware works with DCN-CCU2 and DCNWCCU. Products with the following hardware version have already this firmware installed. Product DCN-WD-D DCN-WDD-D DCN-WDV-D DCN-WDCS-D DCN-WDDCS-D DCN-WDVCS-D Hw 02/04 02/04 02/04 02/05 02/05 02/05 4 Software, Firmware & FPGA versions The table below provides a versions overview of parts which cannot be downloaded using the Download and License Tool or the DCN-UPTK Wireless upgrade Tool kit. Please contact your local Bosch representative how to update these parts. The HW column indicates if the Hardware Version of the product is supported for the listed parts. For product which cannot show the FPGA version, the HW version belonging to the FPGA version is shown between brackets after the FPGA version. DCN-CCU & DCN-WCCU FPGA HW 2.23 ≥ 4.0 2.22 ≥ 4.0 2.20 ≥ 4.0 2.19 ≥ 4.0 2.18 ≥ 4.0 Fixes Slow reacting Multi CCU system Noise or no audio on delegate loudspeaker Unstable system after start-up due to optical network disturbances Noise on delegate loudspeaker Unexpected beeps on delegate loudspeaker fixed DCN-CCUB FPGA 1.22 1.09 1.08 HW ≥ 1.0 ≥ 1.0 ≥ 1.0 Fixes Noise or no audio on delegate loudspeaker Noise on delegate loudspeaker Unexpected beeps on delegate loudspeaker HW ≥ 1.0 ≥ 1.0 Fixes / Additions Address might be lost after system restart 11Khz noise ≥ 1.0 CRC check added for ID-cards DCN-CONxx range FPGA 1.17 (hw1.12) 1.14 (hw1.10) SW 1.10.xxxx (hw1.13) Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes DCN-DDI FPGA 2.2 (hw02.01) 2.0 (hw02.00) HW ≥ 1.0 ≥ 1.0 Fixes / Additions 11Khz noise CRC check added for ID-cards DCN-DIS range FPGA 1.20 (hw02.06) 1.18 (hw02.03) HW ≥ 1.0 ≥ 1.0 1.15 1.13 (hw02.02) ≥ 1.0 ≥ 1.0 Problem fixed 11Khz noise Disturbed audio on headphones for channels > 28 Address might be lost after system restart Channel auto increment equal to DCN-CON Audio distorted on headphones DCN-FCS FPGA 2.7 (hw02.02) HW ≥ 2.0 Fixes 11Khz noise HW ≥ 2.0 Fixes / Additions 11Khz noise ≥ 1.0 DCN-IDESK FPGA 2.1 SW 1.41.xxxx en | 9 1.40.xxxx ≥ 1.0 loudspeaker symbol might be shown in front of the quality indicator after leaving the Idesk’s installation menu B Toggle added INT-TX Range FPGA 02.03 02.02 02.01 02.00 HW ≥ 1.0 ≥ 1.0 ≥ 1.0 ≥ 1.0 Fixes / Additions The display might show unexpected characters Improved stability when used in combination with the DCN system Improved stability when used in combination with the DCN system Initial version Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes en | 10 5 Additional Information to the DCN Manuals and Help Files Reference DCN-CCU2 in Insertion Mode What Figure 3.5 DCN-CCU2 in Insertion Mode in the IUI_DCN is not correct, it should be as depicted below: Wireless Discussion Units Wireless Discussion Units which are produced before 2012 need to be upgraded using the DCN-UPTK and DLT (4.xx) in order to operate with a DCN-CCU2. Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes Reference DCN-SW Print Application en | 11 What To print voting results from a client PC the following changes need to be made: On the PC running the DCN-SW Server: Share the folder as Export • FOR XP share folder: "C:\Documents and Settings\All Users\Application Data\Bosch\DCN Conference Software\\Export" • FOR Vista/Windows 7 share folder: "C:\ProgramData\Bosch\DCN Conference Software\ \Export" On the client: • First check if the client can access the share you defined on the PC running the DCN-SW server. Consult your local IT department in case of any problems. • Install the Print Application on the client. • Stop the Print Application Select “Exit” from the Print Application notification icon. • Go to directory "C:\Program Files\Bosch\Digital Congress Network\DCNSW" • Open file MeetingAnalyser.exe.config • Look for: Change into: Export DCN-SW where [SERVER] is the Computer name or IP-address of the PC running the DCN-SW server. • Safe the files (possible it's needed to copy the documents directory and back to Vista/Win 7) • Restart the application The Agenda in DCN-SW can contain a maximum of 255 characters. Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes Reference LBB 4172/00 (IN_en.pdf) Page 11. Assigning languages to output B en | 12 What nd B toggle (2 B output) on Interpreter desk). The B toggle function on the interpreter desk can be enabled by using software module LBB 4172/00 (only supported for DCN-IDESK SW ≥ 1.40.xxxx). • Select at least two languages for the B-output and check Toggle. • When the B toggle is enabled the interpreter can toggle output B by pressing the B button. The preset of the B output can be changed by press and hold the Boutput button and turn the rotary. Changing the preset can only be done when the microphone is switched off. Note: The software setting is stored in the CCU so the toggle function is still available when the PC is shutdown and after a CCU shutdown. Note: When the B output is changed using interpreter desk menu h the Toggle function is disabled and needs to be enabled using LBB 4172/00. Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes en | 13 Reference DCN NG IUI Figure 34.3 Internal settings What Numbering of connector block DCN-EPS is the other way around DCN-CCU Paragraph 8.3.2 Dipswitch S-600-2 S600-2 is enabled: When the uplink is broken (The unit “thinks” it has a double address): • the red microphone indicator ring of the unit will blink with 2Hz • the unit will not removes its address and keeps it current address • the Red led stops blinking if the uplink connection is restored When unit does not have an address (unit is de-init): • Pressing the mic button will get the unit a new address DCN-MIC*, DCN-DISS-*, DCN-DISL-* Microphones DCN NG IUI Paragraph 33.4.4 DCN NG IUI Paragraph 27.6 DCN NG IUI Paragraph 8.3.2 DCN NG IUI Chapter 49 Correct Wrong S600-2 is disabled: When the uplink is broken (The unit “thinks” it has a double address): • the red microphone indicator ring of the unit will illuminate • the unit removes its address when the mic. button is pressed. All LEDs will be illuminated • the unit will get a new address when pressing the mic. button but only if the Uplink connection is restored When unit does not have an address (unit is de-init): • Pressing the mic button will get the unit a new address • Avoid damage to microphone goosenecks • For the microphones it must be avoided to bend the gooseneck more than 90 degrees or to rotate a (bended) gooseneck. This will cause damage to the windings of the gooseneck. Contact rating (booth-on-air contact) 24 Vdc/ 1A potential free contact Earth loop risk using external sockets When using external sockets of DCN-FCS make sure that all connections are electrically floating. In case any connections are part of an earth loop unexpected system behavior can occur. The same is also valid for DCN-CON, DCN-DIS and DCN-IDESK, DCN-FV Unit address assignment Switch S600-2 On Assignment unit address is disabled Off Assignment unit address is enabled Cards are not conform ISO 7816 Cards are not conform ISO 7816 1 -2, despite the fact that is mentioned in the manual that the cards are conform. Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes Reference Quick Reference Card DCNIDESK LBB4180/00 Delegate database manual Integrus IUI Paragraph 2.4 en | 14 What Channel Quality Overview Push the message button in order to get the channel quality overview. Push again the message button in order to get back the original overview. Pushing any other button, will also return the original overview on the screen. When the interpreter desk received a message, the message button needs to be pushed twice in order to get the channel quality overview. CRC check of ID-cards As from release 2.50 the code written on the ID-card is included a CRC check. This CRC check is only support in DCN-CONFF and DCN-CONCM FW ≥ 1.10 and DCN-DDI hardware version ≥ 2.0. To write a code without CRC-check the following setting must be changed in the DCNNG.INI file: [Database] UseCrcInCard=No Added menu 4B Network mode Menu 4B (Network mode) has been added. Options: • Standalone – use this when the transmitter is not used in combination with DCN Next Generation or DCN wireless. • Enabled – use this when the transmitter is used in combination with DCN Next Generation or DCN wireless. In case ‘standalone’ is selected and the transmitter is connected to a DCN Next Generation or DCN wireless system, the audio in the system can be disrupted. DCN NG IUI Paragraph 2.3 DCN NG IUI Paragraph 2.5.3.1 DCN NG IUI Paragraph 2.5.3.2 In case ‘enabled’ is selected, while no DCN Next Generation or DCN wireless system is connected, the transmitter will show the fault status “Network Error”. Number of optical devices The maximum number of devices that you can connect to the optical network of the central control unit is 18. Power supply introduction 2.5.3.1 Introduction The devices that supply power to the optical network are: • in a single CCU system: the central control unit • in a multi CCU system: the network controller • external power supply connected via a LBB 4410/00 Network Splitter (refer to chapter 41) or LBB4414/10 Fiber Interface (refer to chapter 42) Power supply in a single CCU system 2.5.2 Single CCU system In a single CCU system, the central control unit supplies power to the optical network. The central control unit supplies power to: • the optical network • the DCN sockets • For an overview of the maximum power that the central control unit can supply refer to figure 2.1. • You must install external power supplies in the optical network, in case: • more power is necessary in the optical network • a glass optical fiber is used to connect a remote audio expanders or transmitter Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes Reference DCN NG IUI Paragraph 2.5.3.3 DCN NG IUI Paragraph 8.6 and 10.4 en | 15 What Power supply in a multi CCU system 2.5.3.3 Multi CCU system In a multi CCU system, the network controller supplies the power to the optical network. The DCN-CCUs then only supply power to the DCN sockets and not the optical network. The maximum power that each of the optical network sockets of the network controller can supply is 55 W. • You must install external power supplies in the optical network, in case: • more power is necessary in the optical network • a glass optical fibre is used Downloading Switch the CCUs to “single” mode and change the slave id to “—“ before downloading (refer to menu 7I Multi Mode). DCN NG IUI Paragraph 8.8.2.4 Insertion Insertion mode is changed and has now only effect on the delegate loudspeakers and interpreter floor channel. PA output signal is excluded from the insertion mode. Connect sound processing equipment for PA loudspeakers to output 2. A noise gate is added on the input signal. DCN NG IUI Paragraph 8.8.2.5 DCN NG IUI Paragraph 8.8.2.6 DCN NG IUI Paragraph 10.3.2 Mix Minus A noise gate is added on the input signal. DCN NG IUI 10.10.4 DCNSWSMV DCNSWSMV DCNSWSMV Local Floor Audio output 2 should be audio output 4. DCN-NCO Ground default connected The ground is default connected. When the ground is disconnected, crosstalk can occur on the floor in case an Allegiant Video Switcher is connected to the RS232 port of the DCN-NCO. Note: When the system ground is connected to more than one device in the system, you can create ground loops, which can cause hum. Take care that only the ground of the other devices in the system are note connected. Or alternatively – when no Allegiant Video Switcher is used- disconnect the ground of the DCNNCO. Pop-up message The NCO reports CCU Missing when the Slave ID of a CCU is changed. DCN-SWSMV supports Windows 2000, Windows XP Professional 32 & 64 bits and Windows Vista Home Premium and above 32 & 64 bits. Showing voting results in PowerPoint In case PowerPoint is used to show the voting result, it might happen that PowerPoint starts and overlaps the user interface of DCN-SWSMV completely. Use the Windows task bar to select DCN-SWSMV again. Vote result printout without Bosch Logo When a vote results is need without the Bosch logo 4 files need to be renamed: VotingReport.rpt VotingReportIndividual.rpt VotingReportNoLogo.rpt VotingReportIndividualNoLogo.rpt DCNSWSMV into into into into VotingReportAll.bak VotingReportIndividual.rpt.bak VotingReport.rpt VotingReportIndividual.rpt DCN-SWSMV might become very slow when it is used to control Multi CCU systems. Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes Reference DCN-DLT or DCNSWSMV en | 16 What Starting DCN-DLT or DCN-SWSMV gives error ‘The event log file is full’ For Windows XP and Windows 2000, this can be solved by the following setting: Do a right mouse click on the ‘my computer’ icon on the desk top, to open the ‘Manage’ menu. Select the ‘Event Viewer’. Do a right mouse click on ‘Application’ to select ‘Properties’. Select ‘Overwrite events as needed’ and press ‘OK’ to confirm. For Windows Vista, this can be solved by the following setting: Do a right mouse click on the ‘my computer’ icon on the desk top, to open the ‘Manage’ menu. Select the ‘Event Viewer’. Select ‘Windows Logs’, do a right click on ‘Application’ and select Properties. Select ‘Overwrite events as needed (old events first)’ and press ‘OK’ to confirm. Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes en | 17 6 Additional Information to the Integrus Manual Reference Integrus IUI Several places What Increase coverage of LBB 4511/00 and LBB 4512/00 radiators The information related to the increase of the coverage is valid for the radiators with hardware version 2.00 and higher. Integrus IUI Figure 1.5 Footprint increased with 30%. Integrus IUI Paragraph 2.4 Added menu 4B Network mode Menu 4B (Network mode) has been added. Integrus IUI Paragraph 2.5.7 Removed automatic standby function Automatic standby mode is removed. Reason: the automatic standby switching occasionally resulted in incorrect start-up behavior. Integrus IUI Paragraph 2.5.8 Added menu 4B Network mode Options: • Standalone – use this when the transmitter is not used in combination with DCN Next Generation or DCN wireless. • Enabled – use this when the transmitter is used in combination with DCN Next Generation or DCN wireless. In case ‘standalone’ is selected and the transmitter is connected to a DCN Next Generation or DCN wireless system, the audio in the system can be disrupted. In case ‘enabled’ is selected, while no DCN Next Generation or DCN wireless system is connected, the transmitter will show the fault status “Network Error”. Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes IUI Integrus Paragraph 3.1.1 IUI Integrus Paragraph 3.1.3 en | 18 The LBB 4511/00 has an infra-red output of 22 Wpp, while the LBB 4512/00 has an infra-red output of 42 Wpp. A hole for a safety eye is added to the radiator (hardware version 2.60. Mount the safety eye properly in the hole. Make sure that: - the minimum strength of the safety cord, mounting material, shackle and supporting building structure should withstand 1,500 N. - a proper length safety cord is used (not more than 20 cm longer than needed). WARNING: Suspending any object is potentially dangerous and should only be attempted by individuals who have a thorough knowledge of the techniques and regulations of rigging objects overhead. Bosch strongly recommends that radiators be suspended taking into account all current national, federal, state and local regulations. It is the responsibility of the installer to ensure that radiators are safely installed in accordance with all such regulations. If radiators are suspended, Bosch strongly recommends that the installation is inspected at least once a year. If any sign of weakness or damage is detected, remedial action should be taken immediately. IUI Integrus Paragraph 3.1.3 When a radiator is used with a wall mounting bracket, the mounting plate should be mounted as indicated in figure 3.3. When a radiator is used on a floor stand, the mounting plate should be mounted at the other side of the suspension bracket. This in order to reduce the force on the screws. Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes IUI Integrus Paragraph 3.1.3 en | 19 The mounting plate is changed to the following shape: This plate should be mounted in the way as described above. IUI Integrus Paragraph 7.3.1 Total IR output at 20˚C increase with 30%: • LBB 4511/00: 11 Wrms and 22 Wpp • LBB 4512/00: 21 Wrms and 42 Wpp Total optical peak intensity increased with 30%: • LBB 4511/00: 12 W/sr • LBB 4512/00: 24 W/sr IUI Integrus Paragraph 7.6 See the tables in the appendix for the new guaranteed rectangular footprints. See also the updated footprint calculation tool on this DVD. 7 Trouble Shootings and known issues This trouble shootings and known issues are in addition to chapter 2 and to the trouble shooting chapter in the user manuals. Product/function Problem Solution Not able to DCN-DLT is not able Check if the DCN-SW server is not running: download DCNto download the 1. Exit the DCN-DLT program CCU2 firmware firmware of the CCU 2. Check if the DCN-CCU2 does not report PC on it’s display. If it does Stop the DCN-SW server via Start\ \\[SERVER]\Export SERVICES. Services (local). And check if PC disappears. 3. Start DCN-DLT (PC will now re-appear in the CCU2 screen, but that is correct) and start the download. If the download still fails, do the following: 1. Power off and open the DCN-CCU2 2. Set switch 8 of S600 to ON and power on the CCU. 3. Download the CCU using the DCN-DLT. 4. After a succesfull download, power off the CCU, set switch 8 of S600 to OFF again and power on the CCU. DCN-SWSMV help When opening help Just close the error notification. file file you get an error. DCN-SW In rare occasions it Restart the DCN-SW Configuration Application. Configuration can happen that the Application application closes unintended. Printing individual Individual voting Change the voting template accordingly: voting results results are not printed 1. Check the “Automatic print after stop of the manually when printed voting” checkbox. manually via Bosch 2. Change the settings to Total, groups and DCN SW Print individuals. 3. Uncheck “Automatic print after stop of the Application. voting” checkbox. Bosch Security Systems| 2013-04-26 DCN Next Generation Release Notes Product/function Operator Control Voting control on Layout HD Conference Dome DCN-SW DCN-SW DCN-SW DCN-UPTK DCN-CCU(B)2 DCN-SW DCN-CONFF and DCN-CONCM DCN-SWSACC and Allegiant DCN-SWSACC DCN-SW Problem The Voting control which can be placed on the Layout does not show Group Results. The HD Conference Dome will show an incorrect name & picture combination if a new pre-position is asked before it reaches it’s preposition. Delegate both in Request to speak as Request to respond list. On 64-bit operating systems, it might difficult to find previous SQL-server during DCN-SW installation, when initial SQL-installation was not default. System overview does not show all connected devices when system is still powering up. The type of the unit connected to the UPTK is not valid. Error relays activated upon system reset or firmware download. DCN-SW Master Volume is different from CCU volume control DNPV answers in voting are not visible in the Concentus screen when a voting timer is activated. Double screenlines are still visible on audience screens after switching to single screenlines. Upload does not work anymore. Downgrade to versions <3.10 not possible. Bosch Security Systems| 2013-04-26 en | 20 Solution Use the Voting Results from the Menu Ribbon to show Group Results. Do not activate another microphone until the HD Conference Dome has reached it’s pre-position. If a delegate is both in the Request to Respond as in the Request to Speak list and you want to shift the Request to Speak to Speaking, first cancel the Request to Respond. During installation of DCN-SW the installation process might not be able to find the previous SQL-server, in case during initial installation another name for the SQL-server was created, instead of using the default name. Therefore it is recommended to use the default name and folder during initial SQL-installation. If a SQL-server with a non-default name needs to be found, the correct name should be entered manually in the applicable box during DCN-SW installation. Wait until DCN-system is powered up completely and then check the connected devices via DCN-SW configuration application VIEW \ System Overview. This notification can occur when the DCN-UPTK unit is used extensively. Please replace the connection cable. During a firmware download or system reset, the system is not in normal operation and thus the error relays can be active. When the Master Volume of the CCU has been changed while DCN-SW was disconnected, the DCNSW Master Volume will not reflect the CCU-setting. Changing the DCN-SW volume setting, will make them identical again. Use a hall display or disable the voting timer. Restart the Allegiant. Restart the DCN-CCU or DCN-NCO. Manually uninstall SWL server 2008. Note that the DCN-SW database (the database contains all settings like seats, meetings, synoptic layouts, etc.) will always be removed during a downgrade. DCN Next Generation Release Notes Product/function DCN-SW Problem Unexpected behaviour or no reaction of DCN-SW. DCN-SW DCN-SW installation fails on Windows XP SP3 Generates errors after Windows Stand by.. Secret mode does not work in ad-hoc voting Voting attention tone cannot be changed during a running meeting. Error code 2869 or Fatal error during installation. Windows audio playback is lost after installation DCN-MR 1.3. in windows XP. DCN-SWSMV will not start DCN-SW DCN-SWPV DCN-SWPV DCN-SW setup repair DCN-MR DCN-SWSMV DCN-SWSMV LBB4190/00 LBB 4190/00 LBB 4190/00 Up to 6 CCU supported by the DCN-SWSMV Synoptic Microphone and Voting Software The application does not start. Vote export does not work LBB 4190 gives several errors with title 16 bits Windows or MS-DOS subsystem on the file RNBOVDD.DLL. Bosch Security Systems| 2013-04-26 en | 21 Solution Due to Windows Automatic Updates some critical components like SQL Server Express might be temporarily not available for DCN-SW. Do not set Automatic Updates to Automatic or restart your system after the Automatic updates have been installed. This is a known Microsoft problem. For more information please check: http://support.microsoft.com/kb/968749 Disable Stand by functionality in the Windows operating system. Update to version 2.80 or higher The voting attention tone can be changed in the voting template but becomes effective after a vote has been selected or started. Remove DCN-SW with DCN-SW setup and make a new installation. Settings are stored in the SQLdatabase and can be re-used in the new installation. Replace files msacm32.drv, msadp32.acm and imaadp32.acm in the windows system32 folder. Voting legends cannot be changed into “Not Voted”. Remove “BCPCSettings.xml” which can be found: For XP: “…\Documents and Settings\All Users\Application Data\Bosch\DCN Synoptic Microphone and Voting Software\x.xx” For Vista: “…\Programdata\Bosch\DCN Synoptic Microphone and Voting Software\x.xx” The DCN-SWSMV supports slave CCU ID 1 to 6 in a Multi CCU system set-up. If more CCU’s are required use the DCN Classic software modules. Be sure that the CCU/NCO has the same version as LBB 4190/00. Update to version 2.80 or higher This is a known Microsoft problem. For more information please check: http://support.microsoft.com/default.aspx?scid=kb;ENUS;314452 and re-install LBB 4190/00. DCN Next Generation Release Notes Product/function LBB4180 Delegate database Problem Download user display language list LBB 4190/00 software Error during installation “An installable virtual Device Driver failed DLL installation” DCN-CCU/DCNNCO System might restart when adding optical devices to the system. Multi CCU systems System reaction is (very) slow after system startup. Bosch Security Systems| 2013-04-26 en | 22 Solution When you download to the CCU a user language list different from the default user language list, the first time after installation of the database, the default user language list will be used. Follow the following steps to solve this issue: 1. Connect the PC to the CCU. 2. Create an empty names file. 3. Close the database application. 4. Open the empty names file in the start up application. 5. The next time that you open the database application, the user language list will be matched with the CCU and the issue will be solved. The problem described is a known problem of the Microsoft Windows 2000 and XP operating system. Detail and solution can be found in the following documents: http://support.microsoft.com/default.aspx?scid=kb;ENUS;314452 (windows XP) http://support.microsoft.com/default.aspx?scid=kb;ENUS;254914 (windows 2000) Do not connect optical devices or change optical cables while the system is operational. Always restart the complete system after connecting or disconnecting optical devices. The system might become (very) slow when in a multi CCU system only the NCO is switched off and the rest of the system stays switched on. To prevent this problem: Shutdown all optical devices in the Multi-CCU system. DCN Next Generation Release Notes Product/function DCN-NCO Problem DCN-NCO cannot be downgraded or upgraded. en | 23 Solution A known issue is that DCN-NCO cannot be downgraded from SW 2.70. Workaround 1) Install the Download and License Tool of the version you want to use to downgrade or upgrade to. 2) Open Notepad and paste the text below into Notepad user target password cd /rfa dele PDSDATA1.PDS dele PDSDATA2.PDS bin hash cd /rfa/drv put mmu_3.bit put mif_3.bit cd /bim put dune.bim bye DCN-CCU DCNNCO DCN-NCO DCN-CCU, INT-TX04/08/16/32 DCN NCO DCN-CCU INT-TX04/08/16/32 DCN NCO DCN-CCU INT-TX04/08/16/32 INT-TX04/0816/32 Local floor muted after download of NCO or CCU Unexpected behavior when adding powered system units to the optical ring Audio disruption when switching on a transmitter Audio disruption when one of the CCUs is in the mode “--“ The transmitter displays the message “No Network” Bosch Security Systems| 2013-04-26 3) Save the file in Notepad to C:\Program Files\Bosch\Digital Congress Network\Download and License Tool\Files with name dcn-nco.txt 4) Switch off the NCO and set dipswitch 1 of S3 to on, set all other switches to off 5) Switch on the NCO 6) Open a command prompt (start -> run -> cmd) and change to the following folder: C:\Program Files\Bosch\Digital Congress Network\Download and License Tool\Files 7) Download the NCO with the next command line FTP with the command: ftp -n -s:dcn-nco.txt x.x.x.x Where x.x.x.x is the IP-address of the NCO 8) Switch off the NCO and set the dipswitches all to off 9) Switch on the NCO 10) Start the Download and License Tool and start a NCO download. Switch off and on the CCU or NCO In case system units are added to the optical ring when the system is powered on, unexpected behavior can occur. Only connect units to the optical network when all units are powered off. Select the option “enabled” in menu 4b (network mode). Change the slave id “--" to a number. (refer to menu 7I Multi Mode). Connect a powered DCN Next Generation or DCN wireless system to the transmitter or select the option “standalone” in menu 4b (network mode) DCN Next Generation Release Notes Product/function INT-RX04/08/32 DCN-CCU DCN-CCU DCN-CCU LBB 4402/00 LBB 4404/00 PRS-4DEX4 INT-TX DCN-IDENC Download and License Tool CNConfig DVD WebPages Problem Charging indicator on the receiver is blinking DCN-CCU shows “Multi” while acting in “Single” Audio disruption during powering up/down a CCU in a Multi CCU system Loss of settings after reboot of NCO in a Multi CCU system Input routing does not work after download of optical devices Transmitter does not work after updating firmware DCN-IDENC ID card encoder in not recognized in DCNSW. The Download and License Tool version 2.7x cannot be downgraded to 2.6x and older. Error during installation “…verify that you have access to the directory.” Access denied pop-up when opening the software manual from a network share. Bosch Security Systems| 2013-04-26 en | 24 Solution Check whether the receiver is still working correctly. If this is the case: the battery pack is fully charged and can be recharged after using it a while. If this is not the case: follow the instructions as given in the troubleshooting table. When changing from “single” to “multi” mode, the DCN-CCU can remain working in “single” mode. If this is the case follow next procedure: 1. Select “multi” on all connected CCUs 2. Switch off all CCUs. 3. Reset to defaults the NCO. 4. Switch on all CCUs. During powering up/down a CCU in a Multi CCU system the audio on the delegate units, connected to the remaining CCU’s, is shortly disrupted for 1 to 2 seconds. In case the Network Controller (NCO) in a Multi CCU system is rebooted, the settings and configurations changed during the past 30 seconds can be lost. When configuring interpreter desks wait minimum 30 seconds before reboot the NCO. Change all inputs to CH00 and then to the required channel. Update FPGA to version 2.03 or higher Alternative solution: Update firmware of the INT-TX to version 2.80 If other card readers/encoders are present or connected to the PC please disable them. Internal readers/encoders can be disabled in the BIOS or in the Windows Device Manager. First remove the Download and License Tool version 2.7x before installing Download and License Tool 2.6x and older. Ensure that you have the required administrator rights. Restart installation. Make a copy of the complete file-set on a local hard disk or DVD. DCN Next Generation Release Notes 8 Appendix: Guaranteed Rectangular Footprints See the next table for the guaranteed rectangular footprints in metric units. Bosch Security Systems| 2013-04-26 en | 25 DCN Next Generation Release Notes See the next table for the guaranteed rectangular footprints in imperial units. Bosch Security Systems| 2013-04-26 en | 26
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Modify Date : 2013:04:26 16:04:25+02:00 Create Date : 2013:04:26 16:04:17+02:00 Metadata Date : 2013:04:26 16:04:25+02:00 Creator Tool : Acrobat PDFMaker 10.1 for Word Document ID : uuid:b0898c69-8eb3-427e-9618-38fe7b94d676 Instance ID : uuid:a68b24fc-389c-4bc5-91cc-184e7a2d657b Subject : 62 Format : application/pdf Title : DCN Next Generation 2.40.1586 Description : Creator : Sjack Schellekens Producer : Adobe PDF Library 10.0 Keywords : Source Modified : D:20130426140403 Company : Bosch Communications Systems Comments : Page Layout : OneColumn Page Count : 26 Author : Sjack SchellekensEXIF Metadata provided by EXIF.tools