DLRO100 Series Megger Digital Low Resistance Ohmmeters DLRO100 Series Megger Digital Low Resistance Ohmmeters ■■ CAT IV 600 VAC / 500 VDC for safe operation ■■ Lightweight 100 A battery powered unit for portability ■■ High noise immunity for stable readings ■■ Smooth DC Output for circuit breaker testing ■■ IP54 for protection against dust and moisture whilst testing ■■ Save, download and delete results (100X/H variants) ■■ Remote operation, Bluetooth® & asset/result tagging (100H variants) DESCRIPTION A significant addition to the comprehensive range of Megger Low Resistance Ohmmeters, DLRO100 enables low resistance measurement, across multiple applications, in areas without access to mains power. The integral Li-Ion battery supplies a constant 100 A current for up to 200 Manual/Auto tests to enable enhanced productivity in remote locations. With a focus on user safety, advanced design features ensure the safe operation of the instrument in the most adverse conditions, including a CAT IV 600 VAC / 500 VDC safety rating in accordance with IEC61010. The rugged design, intuitive interface and IP54 (lid open) rating ensure reliability and ease of use in the most arduous of conditions. Test Leads: Standard test leads, with separate Current & Potential, or Kelvin, combining both Current & Potential in one clamp, are available as optional accessories in 5 m, 10 m & 15 m lengths. All test leads are CAT IV 600 VAC / 500 VDC safety rated. Test Modes The Manual test mode allows the user to initiate the test procedure once the probes are in contact with the object under test. Once the TEST button is depressed the TEST lamp will illuminate and the instrument will undertake a single test to verify the resistance of the test object. In Auto mode the user selects the desired current, connects the current test leads and as soon as the potential leads are connected a test will start automatically. To repeat a test, simply break contact with the potential probes and remake contact. In Continuous mode the user connects the test leads and presses the TEST button, initiating the test procedure. The instrument will continue to test, updating the display after each new test cycle, until the TEST button is pressed or the test procedure times out. A new tough adjustable clamp has been designed to ensure flexibility in many applications and provides a good connection with the test piece. History of ‘Ducter’ testing For over 100 years the ‘Ducter test’ has been used to describe a simple test for measuring very low contact resistances and “Ducter”, which is still used as a trade mark, was the name originally given to the low resistance ohmmeter manufactured by Megger. The name Ducter was registered by Megger in June 1908 and ‘Ducter’ has since become the industry standard. DLRO100 Series Megger Digital Low Resistance Ohmmeters APPLICATION SPECIFICATIONS The need for accurate low resistance measurement is well known and very diverse. Typical applications include: Measurement range 0.1 μΩ - 1.999 Ω Resolution 0.1 μΩ Noise rejection Differential 100 mV @ 50-60 Hz on Test Leads DC output Smooth DC IP rating IP54 Lid open / IP65 Lid closed Operating temperature range -20°C up to 50°C Utilities & Service Contractors – commissioning new installations & regular maintenance testing of ■■ Switchgear and circuit breaker contact resistance ■■ Busbar and cable joints ■■ Wire and cable resistance ■■ Lightning conductor bonding Storage temperature range -30°C up to 70°C Original Equipment Manufacturer – detecting manufacturing defects Humidity <85% R.H. non-condensing Battery life 200 single 100 A tests or up to 2x 10 minutes continuous 100 A output Battery type User replaceable Li-ion battery pack ■■ Production test of circuit breakers – contacts & joints ■■ Production test of high voltage switchgear ■■ Production test of welded joints & connections Battery charge time Full charge in 2.5 Hrs from flat Transport – manufacturing & maintenance Maximum output voltage 2 V (battery), 3 V (AC) ■■ Railway rolling stock ground connections & manufactured joints EMC IEC61326-1 Safety IEC61010 CAT IV 600 VAC / 500 VDC up to 2000 m CAT IV 300 V up to 4000 m Dimensions 400 x 300 x 200 mm Weight 7.0 kg (AC Only) 7.9 kg (with Battery) ■■ Railway lines & conductor rails – commissioning & maintenance ■■ Aircraft frame bonds and static control circuits Accuracy Current setting# Resistance range 50 - 110 A 0 - 100.00 mΩ 11 - 49 A 10 μΩ - 100.00 mΩ 10 A 10 μΩ - 1000.0 mΩ accuracy Typical ± (0.2% + 0.2 μΩ) Max. ± (0.2% + 0.8 μΩ)* Typical ± (0.2% + 0.5 μΩ) Max. ± (0.2% + 2.0 μΩ)* Typical ± (0.2% + 1.0 μΩ) Max. ± (0.2% + 2.5 μΩ)* # Actual test current may be limited by maximum output voltage * k = ±4σ Operational uncertanity, 85% RH, -20°C to +50°C Current setting# 50 - 110 A 11 - 49 A 10 A Resistance range 0 - 100.00 mΩ 10 μΩ - 100.00 mΩ 10 Ω - 1000.0 mΩ + ± (0.0% + 0.0 μΩ) ± (0.0% + 1.0 μΩ) ± (0.1% + 2.0 μΩ) The Bluetooth ® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc and is used under licence. 2 DLRO100 Series Megger Digital Low Resistance Ohmmeters FEATURES AND BENIFITS DLRO100 Features E EB X XB H HB Benefits CAT IV 600 VAC / 500 VDC up to 2000 m n n n n n n On all test terminals for safe operation n Easily portable – 7.9 Kg (17 lbs) with battery CAT IV 300 V up to 4000 m Lightweight 100 A battery powered unit n n Mains only units for manufacturing and production applications where AC is always available. Weight 7.0 Kg (15.5 lbs) Mains only n High noise immunity n n n n n n For stable readings in noisy environments Smooth DC Output n n n n n n Circuit breaker testing n n n n n n For protection against ingress during operation (lid open) and storage (lid closed) IP54 Lid open IP65 Lid closed n n Always ready to test with a Li-ion fast charge battery - 2.5 hours charge time from fully discharged Li-ion battery n n n Works from an AC supply if the battery is fully discharged Battery capacity - 200 single tests or up to 2x 10 minutes continuous 100 A output for extended use 100A Manual, n n n n n n Quick selection of test modes for different applications with 4 terminal measurement for flexibility Custom test n n n n n n Adjustable current 10 - 110 A, ramp rates configurable from 0.5s upto 30s and configurable test duration for flexibility Range and test mode rotary switches n n n n n n Quick and easy selection of current ranges and test modes Ultra tough outer case construction n n n n n n Designed for use in demanding environments with a flame retardant UL94 V0 inner case for safety n* n* n* n* Using the optional DC clamp enables circuit breaker testing with ground protection in place for safety n n n n Ideal for all light conditions, with backlight n n n n For effective results management, up to 220 time and date stamped records Remote Control n n Control the instrument remotely over USB via a PC or laptop for added safety Asset tagging n n Running a PowerDB app on Windows tablet or smart phone to populate unique asset IDs for efficient asset management Bluetooth® n n For effective wireless communication. For download and asset tagging Auto and Continuous test Dual Ground™ Large, clear LCD Internal memory storage with USB download capability n n * with optional Clamp All models. Two year warranty - second year conditional on free product registration. 3 DLRO100 Series Megger Digital Low Resistance Ohmmeters Display clearly showing large digits for test results and visible in all light conditions Single button to save test results and to automatically save in auto mode IP54 for protection against dust and rain during testing Back light for low light conditions Smooth DC Output on C1 and C2 terminals High noise immunity on P1 and P2 terminals USB & Bluetooth for communications CAT IV 600 VAC / 500 DV safety rating on all terminals Rotary switch selection of test modes and off position Simple navigation of setup and stored results Clearly visible C and P LED’s showing continuity of current and potential connections DualGroundTM capability with the DC clamp Rotary switch selection of view, download and delete test results User configurable custom test. Adjustable : ■■ current ramp ■■ duration of test ■■ output current A new terminal adapter has been designed to enable the use of users own test leads. Quick and easy rotary switch selection of 10 A, 50 A, 100 A tests - no configuration required A user replaceable high power lightweight Li-ion battery provides, from a single charge, 200 Manual/Auto 100 A tests or up to two 10 minutes continuous 100 A tests and takes 2.5 hours to charge when fully discharged. 4 Model name Language D L R O 1 0 0 - Plug/Mains lead L G - P SELECT A MODEL DLRO100H (mains only) DLRO100HB (mains and battery) DLRO100X (mains only) DLRO100XB (mains and battery) DLRO100E (mains only) DLRO100EB (mains and battery) SELECT A LANGUAGE AND PLUG Please note only some plug types are available for certain languages - the language you need will determine the mains leads available LANGUAGE 3 DIGIT CODE PLUG TYPES AVAILABLE LANGUAGE INCLUDED UK BS 1363 UK BS 1363 LG1 LG2 LG3 LG4 LG5 LG6 LG7 EN, DE, FR, NL EN, ES, PT, IT EN, AR, TR, FR EN, CZ, SK, PL EN, CN, JA, KO EN, RU, HU, RO EN, NO, SV, FI European Schuko CEE7/7 UK EU P1 P1 P1 P1 P1 - P2 P2 P2 P2 P2 P2 P2 US NEMA WD6 15-5P Swiss SN SEV 1011 US CH P3 P3 P3 - P4 - Italian CEI 23-16 AUS IT P5 - P6 - Australian/New Zealand AS/NZS 3112 SU P5-51 6DW AMEN Indian/S.African IN BS 546 UK + US P7 - P8 - ORDERING INFORMATION Description Order Code Description Order Code Included Items Optional Accessories Certificate of Test DLRO100 CAT IV 600V Lead Set (5m) 1004-448 Quick Start Guide DLRO100 CAT IV 600V Lead Set (10m) 1004-449 Calibration Certificate DLRO100 CAT IV 600V Lead Set (15m) 1004-450 CD containing the User Guide DLRO100 Terminal Adaptors (x2) 1005-555 Mains lead DLRO100 Lead Set Adaptors (10 A Leads) 1008-604 USB Cable (X, H variants only) DLRO100 CAT IV 600 V Kelvin Lead Set (5m) 1005-634 DLRO100 CAT IV 600 V Kelvin Lead Set (10m) 1005-635 DLRO100 CAT IV 600 V Kelvin Lead Set (15m) 1005-636 DLRO100 DC Clamp (MCPD 100L) 1005-622 Lead set is NOT included with the instrument and must be ordered as an optional accessory. DLRO100 ISO17025 (UKAS) Calibration Certificate 1005-888 DLRO100 Lithium Ion Battery Pack SALES OFFICE Megge Limited Archcliffe Road Dover CT17 9EN England T +44 (0) 1304 502101 E UKsales@megger.com DLRO100_DS_en_V05 www.megger.com ISO 9001:2008 The word ‘Megger’ is a registered trademark 1005-973
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.6-c111 79.158366, 2015/09/25-01:12:00 Create Date : 2016:08:04 11:18:48+01:00 Metadata Date : 2016:08:04 11:18:55+01:00 Modify Date : 2016:08:04 11:18:55+01:00 Creator Tool : Adobe InDesign CC 2015 (Macintosh) Instance ID : uuid:488d3499-893c-db49-80ab-31a2b692574f Original Document ID : xmp.did:F77F117407206811822AC3B079758906 Document ID : xmp.id:66e719be-ffc9-4dd3-b061-9f14025888e6 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:7e0eab84-df5c-4df0-bcd5-b498f3745cbd Derived From Document ID : xmp.did:7e0eab84-df5c-4df0-bcd5-b498f3745cbd Derived From Original Document ID: xmp.did:F77F117407206811822AC3B079758906 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2015 (Macintosh) History Changed : / History When : 2016:08:04 11:18:48+01:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 5 Creator : Adobe InDesign CC 2015 (Macintosh)EXIF Metadata provided by EXIF.tools