DTA 100 C BAUR oil breakdown voltage tester Features ▪▪ Test voltages of 0 to 100 kVrms ▪▪ Reliable, reproducible measurement results across multiple measurements thanks to short switch-off time < 10 µs ▪▪ Clear breakdown detection by means of very precise measurement principle performed directly in the HV part and RBM technology ▪▪ Fully automatic test sequences for 18 common test standards around the globe and spot tests The standard in oil testing in the laboratory ↗↗ Fully automatic testing of the breakdown strength in compliance with international and national standards ↗↗ Suitable for mineral or silicone oils and esther liquids ↗↗ Reliable, reproducible measurement results using the latest measurement technology ↗↗ Designed for daily continuous operation in laboratories The BAUR DTA 100 C oil breakdown voltage tester fully automatically tests the electrical breakdown strength of insulating liquids. Test sequences can be accomplished easily and fully automatically in compliance with all international and national standards. With reliable, informative test results it is possible to determine the exact condition of the insulating material and initiate any necessary measures, e.g. preparation of transformer oil. The high precision of the BAUR oil breakdown voltage testers is based on a tried and tested and very accurate test voltage measurement principle performed directly on the HV part of the device, as well as the permanent monitoring of the voltage slew (RBM). The especially short switch-off time after a breakdown counteracts the contamination of the oil sample, thus ensuring reliable reproducibility of the measurement results. The DTA 100 C oil breakdown voltage tester has been specially designed for contin- ▪▪ Easy creation of user-specific test sequences ▪▪ Built-in sensor for measuring the temperature of the insulating liquid ▪▪ Precise adjustment of standard electrode distances ▪▪ Automatic self-test with HV output voltage test each time you start ▪▪ EMC screen for preventing damage to electronic devices nearby ▪▪ Comprehensive safety concept, incl. high voltage shutdown through hood contacts ▪▪ User interface available in 13 languages ▪▪ Illuminated test vessel ▪▪ Ergonomic operating unit with oil-proof membrane keyboard, easy to read LCD colour display and integrated printer ▪▪ Automatic reading of measurement results and creation of measurement logs in PDF format or as text file with BAUR oil tester data management software ITS Lite * –– Management of measurement results for multiple oil testers possible –– Customised layout of measurement logs * Free download at www.baur.eu uous operation in laboratories. The robust and sophisticated design guarantees safe and failure-free operation for several hundred thousands of oil sample measurements. BAUR GmbH · Raiffeisenstraße 8, 6832 Sulz, Austria · T +43 (0)5522 4941-0 · F +43 (0)5522 4941-3 · headoffice@baur.at · www.baur.eu Technical data General Insulating oil testing Input voltage 90 – 264 V (50/60 Hz) Output voltage 0 – 100 kVrms symmetrical Power consumption Max. 70 VA Voltage slew rate 0.5 – 10 kV/s LCD colour display (320 x 240) Display Data interface Switch-off time < 10 μs ▪▪ USB 2.0 (type B plug) Voltage slew monitoring Real Breakdown Monitoring (RBM) ▪▪ BAUR Report Manager external USB interface (type A plug) Accuracy 0 – 100 kV ± 1 kV Resolution 0.1 kV Internal temperature recording of the oil sample 0 – 99°C Temperature resolution 1°C Test standards ASTM D1816:2012 1 mm, ASTM D1816:2012 2 mm, ASTM D1816/97, ASTM D877/D877M:2013 PA, ASTM D877/D877M:2013 PB, BS EN 60156, CEI EN 60156, CSSR RVHP:1985, IEC 60156:1995, IRAM 2341:1972, JIS C2101:2010, PN 77/E-04408, SEV EN 60156, UNE EN 60156, NF EN 60156, SABS EN 60156, VDE 0370 Part 5:96, AS 1767.2.1 User-specific test sequences 10 Printer Matrix printer, 24 characters, 57 mm plain paper Ambient temperature (operational) -10°C to +55°C Storage temperature -20°C to +60°C Humidity Non-condensing Dimensions (W x H x D) 545 x 458 x 380 mm (closed) 545 x 770 x 461 mm (open) Weight Approx. 39 kg Degree of protection IP 32 Safety and EMC CE-compliant in accordance with Low Voltage Directive (2014/35/EC), EMC Directive (2014/30/EC), EN 60068-2-ff Environmental testing Software available in German, English, French, Spanish, Portuguese, Italian, Russian, Czech, Polish, Dutch, Chinese (CN), Chinese (TW), Korean Standard delivery includes Available test vessels 0.4 litres made of glass (with lid) ▪▪ BAUR DTA 100 C oil breakdown voltage tester incl. integrated plain paper printer ▪▪ Lifting stick for magnetic stirrer ▪▪ 1 x test vessel (test standard acc. to choice) ▪▪ Setting gauge Test vessel according to ▪▪ Mains supply cord IEC 60156 Fig. I ▪▪ Magnetic stirrer ▪▪ User manual Test vessel according to Options IEC 60156 Fig. II ▪▪ Dust cover ▪▪ Ink ribbon (blue) for printer ▪▪ Transport case ▪▪ Test vessels 0.4 litre made of glass according to IEC 60156 Fig. I or Fig. II, ASTM D1816 or ASTM D877 ▪▪ Magnetic stirrer ▪▪ Lifting stick for magnetic stirrer ▪▪ Setting gauges, 1 / 2 / 2.5 / 2.54 / 4 / 5 mm ▪▪ Face pin wrench for disassembling the test vessel ▪▪ Paper roll for printer, 57 mm width, Ø 30 mm ▪▪ Pairs of electrodes for test vessels in accordance with IEC 60156 Fig. I or Fig. II, ASTM D1816 or ASTM D877 ▪▪ BAUR Report Manager – External USB interface for measurement data management Data sheet: BAUR GmbH · 826-089-6 · 06.2017 · Subject to modifications Test vessel according to ASTM D877 Test vessel according to ASTM D1816
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Print high-res Create Date : 2017:06:01 11:35:15+02:00 Creator : Adobe InDesign CS6 (Windows) Modify Date : 2018:01:04 08:37:18+01:00 Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Metadata Date : 2018:01:04 08:37:18+01:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:7f73ec61-db64-45e8-8edb-c781fd5e38ab Original Document ID : xmp.did:7EE2B9CC372068118083E8C7FDADF317 Document ID : xmp.id:1BBBCB97AD46E7118C5C9777C30B78CD Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:1ABBCB97AD46E7118C5C9777C30B78CD Derived From Document ID : xmp.did:A04C6FF85CFDE411AB6DB0D01487808B Derived From Original Document ID: xmp.did:7EE2B9CC372068118083E8C7FDADF317 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2017:06:01 11:35:15+02:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Layout : SinglePage Page Count : 2EXIF Metadata provided by EXIF.tools