TM

In order to make the best use of your
investment, familiarize yourself with the
new features and operating instructions
before starting pump. With just routine
care your FastVac will give you years of
reliable service by following proper
maintenance guidelines. FastVac pumps
are designed for deep vacuum work in
refrigeration systems only.

EXHAUST

DV-42N, DV-85N, DV-142N,
DV-200N and DV-285N,
Deep Vacuum Pumps,
OPERATING INSTRUCTIONS,
& PARTS MANUAL,
2-Stage,
Direct Drive

INTAKE

IMPORTANT: Use oil specifically refined
for deep vacuum pumps. Using oil not
refined for deep vacuum pumps and/or
operating with contaminated oil will void
warranty.
Each FastVac pump has been factory
tested to guarantee 25 micron or better
and listed CFM performance. The serial
number has been recorded. Complete and
mail the Warranty Registration Card within
10 days of purchase to validate your
warranty. You will be notified of any
technical updates.
ISOLATION
(BLANK-OFF)
VALVE

25,400 Microns = 1"

Specifications
DV-42N, DV-85N,
DV-142N, DV-200N & DV-285N



MOTOR
1/2 HP, 60 HZ, 1725 RPM; Capacitor start;
Automatic thermal overload protected.
INTAKE
DV-42N
1/4 Male Flare
DV-85N
1/4 x 3/8 Male Flare
DV-142N,
3/8 x 1/4 x 3/8 Male Flare
DV-200N & DV-285
FREE AIR DISPLACEMENT
CFM
Liters Per Minute
DV-42N
1.5
42
DV-85N
3
85
DV-142N
5
142
DV-200N
7
200
DV-285N
10
285

GAS BALLAST
VALVE

OIL FILL PLUG
Do Not Wrench
Down Or Use
Sealant On
Threads

-250 Series
MOTOR
1/2 HP, Dual Cycle, 50/60 HZ, 1425/1725 RPM;
Capacitor start; Automatic thermal overload
protected.
INTAKE PORT
See Above
FREE AIR DISPLACEMENT
50 HZ
60 HZ
Liters Per
Liters Per
CFM
Minute
CFM
Minute
DV-42N-250
1.25
35
1.5
42
DV-85N-250
2.5
71
3
85
DV-142N-250 4.2
119
5
142
DV-200N-250 5.8
167
7
200
DV-285N-250 8.3
237
10
285

OIL DRAIN VALVE
Close Drain Finger
Tight.

IMPORTANT
This unit has been drained for shipment.
DO NOT ATTEMPT TO OPERATE
WITHOUT ADDING OIL.
1

ISOLATION
(BLANK-OFF) VALVE

OIL
CAPACITY
DV-42N
30 oz. (865 cc)

OPEN
POSITION

DV-85N
27 oz. (785 cc)
DV-142N
23 oz. (660 cc)

PAUSE
POSITION

Being just a teaspoon
low affects the ultimate
vacuum.

DV-200N
23 oz. (660 cc)

CLOSED
POSITION

DV-285N
24 oz. (705 cc)
Slowly add oil until oil level rises to the
top of OIL LEVEL line. Replace oil fill
plug.
If oil is too low, you will hear the exhaust
baffle chatter. If the oil level is too high,

excess oil will be blown out the exhaust.
Pump oil should be changed after each
use. If system is heavily contaminated, oil
may have to be changed several times
during evacuation.

OPERATION
IMPORTANT
DO NOT START PUMP BEFORE ADDING OIL
The following procedures will prevent oil from being drawn
into cartridge and creating hard start-up.
START-UP
Open one intake port and isolation valve,
close gas ballast valve and start pump.
Make vacuum connections.
Crack gas ballast valve for the first part of
the evacuation procedure. After pump
quiets down from initial volume of air,
close valve and continue evacuating.
Failure to close valve will result in poor
pump performance.

SHUT-DOWN
Crack gas ballast valve. Continue running
pump for 2-3 seconds. With valve still
cracked, stop pump. Close isolation valve
and gas ballast valve.
Remove hose connections and cap
intakes.

CHANGING OIL
To reach deep vacuum, FastVac pumps need
clean, moisture-free oil throughout evacuation.

Quarter-turn on/off. No additional valve
needed to isolate system.
When checking pressure rise, slowly turn
handle counter-clockwise. Pause at 45°.
Valve completely closed at 90°.

PUMP MOTOR
Pump and oil must be above 30°F. Line
voltage must be equal to motor
nameplate ±10%. Normal operating
temperature is approximately 160°F,
which is hot to the touch. Line voltage and
ambient conditions will affect this
somewhat. Motor has automatic resetting
thermal overload protection. FastVac is
designed for continuous duty and will run
for extended periods without overheating.

DIGITAL
VACUUM
GAUGES

Care should be taken to avoid contact on skin and clothing when changing oil.
Used oil should be disposed of in a leakproof corrosive-resistant container.
1. After every evacuation while pump is warm and oil is thin, place
pump on level surface and open oil drain. Oil can be forced from
the pump by opening one intake and partially blocking the
exhaust with a cloth while the pump is running. Do not operate
the pump for more than 20 seconds using this method.

DV-22
Battery

2. Close drain. Remove oil fill cap and fill to top of OIL LEVEL line
with FastVac Pump Oil. Replace oil fill cap.

DV-20
Battery/Electric

FLUSHING
If the oil is badly contaminated, flushing may be
necessary. Slowly pour 1/3–1/2 cup of fresh FastVac
oil into the intake connection while pump is running.
Repeat as required until contamination is removed
from oil reservoir, pump rotors, vanes and housing.
Dispose of all oil used in flushing of pump.

Both Gauges Feature
Digital Display With Solid State Circuitry
+32°F to +120°F (0°C to 48.9°C)
Ambient Temperature
● NIST Traceable
● Solid State Design – No Adjustment
Necessary For Temperature
● Automatic Power Off Battery Saver
● Saves Last Vacuum
Readout After Shutdown
●
●

After Evacuation, Oil Contains Rust
Forming Water and Corrosive Acids.
Drain Immediately While Pump Is Warm.

●

2

Low Battery Indicator

REPAIR PARTS

20
18

11

19

Please provide following information:
–Model number
–Four digit serial number
–Part description and number as shown in parts list

21
22

12

23

15

17

6
16

24

14

5

25

7

13
12

12

9

8

10
4
1

11

2
3

Ref.
No.

1
2

Part
No.

PR-1
PR-2
PR-300

3

4

5
6
7
8
9
10
11
12
13

PR-301
PR-305
PR-302
PR-303
PR-304
PR-314
PR-311
PR-211
PR-3
PR-315
PR-4
PR-24
NFT5-4
NFT5-6
PR-32

Description

Sight Glass
Drain Valve
DV-42N through DV-200N Cover Assy.
w/Sight Glass and Drain Valve
DV-285N Cover Assy. w/Sight Glass and Drain Valve
DV-42N Cartridge w/O-Rings and Cover Seal
DV-85N Cartridge w/O–Rings and Cover Seal
DV-142N Cartridge w/O–Rings and Cover Seal
DV-200N Cartridge w/O–Rings and Cover Seal
DV-285N Cartridge w/O–Rings and Cover Seal
Cover Seal
Trap O-Ring, Gas Ballast
Shaft Seal
Trap O-Ring, Intake
Rubber Foot & Screw Assy. (1 per pkg.)
Intake Cross with Caps
1/4" O-Ring Cap
3/8" O-Ring Cap
1/4" Intake with Cap

Ref.
No.

Part
No.

14
15
16
17
18

PR-209
PR-208
PR-42
PR-31
PR-54
PR-206
PR-207

19

20 PR-5
21 PR-7
22 P90009
23 PR-40
24 PR-205
25 PR-22
Not Shown
PR-18
PR-52
PR-45

3

Description

Plastic Isolation Valve Handle & Screw
Flexible Coupler
Motor Foot & Screw
Line Cord (Emerson Motor)
Rocker Switch (Emerson Motor)
1/2 HP, 115V, 60HZ Motor w/Line Cord and Switch
1/2 HP, 115/230V, 50/60 HZ Motor w/Line Cord
and Switch
Intake Tee with Caps
Gas Ballast Valve w/O-Ring
O-Ring, Gas Ballast Valve
Splash Guard and Screw
Cushioned Handle w/Lift Loop
Oil Fill Plug w/O-Ring
Cartridge Valve Repair Kit (Excluding 285N)
DV-285N Cartridge Valve Repair Kit
Pump Repair Kit: PR-1, PR-2, PR-4(2),
PR-42, PR-208

TROUBLESHOOTING CHART
Symptom

Possible Cause(s)

Corrective Action

1. Power cord not plugged in securely.

1. Plug power cord in securely.

2. Motor switch not on.

2. Turn motor switch to ON position.

3. Pump temp. below 30°F.

3. Warm up pump to 30°F & turn motor
switch on.

4. Inconsistent line voltage.

4. Line voltage must be within 10% of
115 volt.

1. Contaminated oil.

1. Change oil.

2. Oil level too low.

2. Add oil.

3. Air leak in system being evacuated.

3. Locate & repair leaks.

4. Gas ballast O-ring dirty or cut.

4. Clean or replace O-ring.

5. Pump inlet fittings missing or not
tightened.

5. Replace or tighten.

Oil drips from point where shaft
enters the pump housing.

Damaged oil seal.

Replace.

Pump shuts down and will not start.

Thermal overload may be open.

Disconnect pump from system. Wait about
15 minutes for motor to cool and turn it on
again. If it cycles off again, return pump to
factory for repair.

Pump cycles on and off from a
completely cold start and then runs
smoothly.

Oil backed up into cartridge and was
being cleared out. Pump has not been
shutdown properly.

1. Remove 1/4" cap.

Pump won’t start.

Pump won’t pull deep vacuum.

2. Move blank-off handle to open position.
3. Turn pump on.

WARRANTY
FastVac pumps are warranted against defects in materials and workmanship for 1 year. All J/B products are guaranteed
when used in accordance with our directions and recommendations, and we limit this warranty to the repair, replacement,
or credit at invoice price (our option) of products which in our opinion are defective due to defects in workmanship and/or
materials. In no case will we allow charges for labor, expense or consequential damage. Repairs performed on items out
of warranty will be invoiced on a nominal basis. Contact you wholesaler for details.

Should you need further assistance,
write our Home Office or contact your
nearest J/B Service Center.

MAIN WAREHOUSE
J/B INDUSTRIES, INC.
P.O. Box 1180–Dept. 85
Aurora, Illinois 60507-1180 USA
E-mail: sales@jbind.com
Visit our web site at: www.jbind.com
Toll Free Technical Service
Number 1-800-323-0811

Form 10185-308
Printed in U.S.A.
 2001 J/B Industries Inc.

CANADA
ALLTEMP PRODUCTS CO., LTD.
827 Brock Road South
Pickering, Ont., Canada L1W 3J2
Phone: (905) 831-3311
Fax: (905) 831-1864

Aurora, Illinois 60507-1180 USA

4



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 4
Create Date                     : 2001:05:30 16:23:02
Producer                        : Acrobat Distiller 3.02 for Power Macintosh
Subject                         : DV42_285Eng
Creator                         : Adobe PageMaker 6.52
Title                           : DV42_285Eng
Author                          : 
EXIF Metadata provided by EXIF.tools

Navigation menu