DV42_285Eng DV42 285Eng
User Manual: DV42-285Eng Igor's of metalworking and electrical manuals
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
TM In order to make the best use of your investment, familiarize yourself with the new features and operating instructions before starting pump. With just routine care your FastVac will give you years of reliable service by following proper maintenance guidelines. FastVac pumps are designed for deep vacuum work in refrigeration systems only. EXHAUST DV-42N, DV-85N, DV-142N, DV-200N and DV-285N, Deep Vacuum Pumps, OPERATING INSTRUCTIONS, & PARTS MANUAL, 2-Stage, Direct Drive INTAKE IMPORTANT: Use oil specifically refined for deep vacuum pumps. Using oil not refined for deep vacuum pumps and/or operating with contaminated oil will void warranty. Each FastVac pump has been factory tested to guarantee 25 micron or better and listed CFM performance. The serial number has been recorded. Complete and mail the Warranty Registration Card within 10 days of purchase to validate your warranty. You will be notified of any technical updates. ISOLATION (BLANK-OFF) VALVE 25,400 Microns = 1" Specifications DV-42N, DV-85N, DV-142N, DV-200N & DV-285N MOTOR 1/2 HP, 60 HZ, 1725 RPM; Capacitor start; Automatic thermal overload protected. INTAKE DV-42N 1/4 Male Flare DV-85N 1/4 x 3/8 Male Flare DV-142N, 3/8 x 1/4 x 3/8 Male Flare DV-200N & DV-285 FREE AIR DISPLACEMENT CFM Liters Per Minute DV-42N 1.5 42 DV-85N 3 85 DV-142N 5 142 DV-200N 7 200 DV-285N 10 285 GAS BALLAST VALVE OIL FILL PLUG Do Not Wrench Down Or Use Sealant On Threads -250 Series MOTOR 1/2 HP, Dual Cycle, 50/60 HZ, 1425/1725 RPM; Capacitor start; Automatic thermal overload protected. INTAKE PORT See Above FREE AIR DISPLACEMENT 50 HZ 60 HZ Liters Per Liters Per CFM Minute CFM Minute DV-42N-250 1.25 35 1.5 42 DV-85N-250 2.5 71 3 85 DV-142N-250 4.2 119 5 142 DV-200N-250 5.8 167 7 200 DV-285N-250 8.3 237 10 285 OIL DRAIN VALVE Close Drain Finger Tight. IMPORTANT This unit has been drained for shipment. DO NOT ATTEMPT TO OPERATE WITHOUT ADDING OIL. 1 ISOLATION (BLANK-OFF) VALVE OIL CAPACITY DV-42N 30 oz. (865 cc) OPEN POSITION DV-85N 27 oz. (785 cc) DV-142N 23 oz. (660 cc) PAUSE POSITION Being just a teaspoon low affects the ultimate vacuum. DV-200N 23 oz. (660 cc) CLOSED POSITION DV-285N 24 oz. (705 cc) Slowly add oil until oil level rises to the top of OIL LEVEL line. Replace oil fill plug. If oil is too low, you will hear the exhaust baffle chatter. If the oil level is too high, excess oil will be blown out the exhaust. Pump oil should be changed after each use. If system is heavily contaminated, oil may have to be changed several times during evacuation. OPERATION IMPORTANT DO NOT START PUMP BEFORE ADDING OIL The following procedures will prevent oil from being drawn into cartridge and creating hard start-up. START-UP Open one intake port and isolation valve, close gas ballast valve and start pump. Make vacuum connections. Crack gas ballast valve for the first part of the evacuation procedure. After pump quiets down from initial volume of air, close valve and continue evacuating. Failure to close valve will result in poor pump performance. SHUT-DOWN Crack gas ballast valve. Continue running pump for 2-3 seconds. With valve still cracked, stop pump. Close isolation valve and gas ballast valve. Remove hose connections and cap intakes. CHANGING OIL To reach deep vacuum, FastVac pumps need clean, moisture-free oil throughout evacuation. Quarter-turn on/off. No additional valve needed to isolate system. When checking pressure rise, slowly turn handle counter-clockwise. Pause at 45°. Valve completely closed at 90°. PUMP MOTOR Pump and oil must be above 30°F. Line voltage must be equal to motor nameplate ±10%. Normal operating temperature is approximately 160°F, which is hot to the touch. Line voltage and ambient conditions will affect this somewhat. Motor has automatic resetting thermal overload protection. FastVac is designed for continuous duty and will run for extended periods without overheating. DIGITAL VACUUM GAUGES Care should be taken to avoid contact on skin and clothing when changing oil. Used oil should be disposed of in a leakproof corrosive-resistant container. 1. After every evacuation while pump is warm and oil is thin, place pump on level surface and open oil drain. Oil can be forced from the pump by opening one intake and partially blocking the exhaust with a cloth while the pump is running. Do not operate the pump for more than 20 seconds using this method. DV-22 Battery 2. Close drain. Remove oil fill cap and fill to top of OIL LEVEL line with FastVac Pump Oil. Replace oil fill cap. DV-20 Battery/Electric FLUSHING If the oil is badly contaminated, flushing may be necessary. Slowly pour 1/3–1/2 cup of fresh FastVac oil into the intake connection while pump is running. Repeat as required until contamination is removed from oil reservoir, pump rotors, vanes and housing. Dispose of all oil used in flushing of pump. Both Gauges Feature Digital Display With Solid State Circuitry +32°F to +120°F (0°C to 48.9°C) Ambient Temperature ● NIST Traceable ● Solid State Design – No Adjustment Necessary For Temperature ● Automatic Power Off Battery Saver ● Saves Last Vacuum Readout After Shutdown ● ● After Evacuation, Oil Contains Rust Forming Water and Corrosive Acids. Drain Immediately While Pump Is Warm. ● 2 Low Battery Indicator REPAIR PARTS 20 18 11 19 Please provide following information: –Model number –Four digit serial number –Part description and number as shown in parts list 21 22 12 23 15 17 6 16 24 14 5 25 7 13 12 12 9 8 10 4 1 11 2 3 Ref. No. 1 2 Part No. PR-1 PR-2 PR-300 3 4 5 6 7 8 9 10 11 12 13 PR-301 PR-305 PR-302 PR-303 PR-304 PR-314 PR-311 PR-211 PR-3 PR-315 PR-4 PR-24 NFT5-4 NFT5-6 PR-32 Description Sight Glass Drain Valve DV-42N through DV-200N Cover Assy. w/Sight Glass and Drain Valve DV-285N Cover Assy. w/Sight Glass and Drain Valve DV-42N Cartridge w/O-Rings and Cover Seal DV-85N Cartridge w/O–Rings and Cover Seal DV-142N Cartridge w/O–Rings and Cover Seal DV-200N Cartridge w/O–Rings and Cover Seal DV-285N Cartridge w/O–Rings and Cover Seal Cover Seal Trap O-Ring, Gas Ballast Shaft Seal Trap O-Ring, Intake Rubber Foot & Screw Assy. (1 per pkg.) Intake Cross with Caps 1/4" O-Ring Cap 3/8" O-Ring Cap 1/4" Intake with Cap Ref. No. Part No. 14 15 16 17 18 PR-209 PR-208 PR-42 PR-31 PR-54 PR-206 PR-207 19 20 PR-5 21 PR-7 22 P90009 23 PR-40 24 PR-205 25 PR-22 Not Shown PR-18 PR-52 PR-45 3 Description Plastic Isolation Valve Handle & Screw Flexible Coupler Motor Foot & Screw Line Cord (Emerson Motor) Rocker Switch (Emerson Motor) 1/2 HP, 115V, 60HZ Motor w/Line Cord and Switch 1/2 HP, 115/230V, 50/60 HZ Motor w/Line Cord and Switch Intake Tee with Caps Gas Ballast Valve w/O-Ring O-Ring, Gas Ballast Valve Splash Guard and Screw Cushioned Handle w/Lift Loop Oil Fill Plug w/O-Ring Cartridge Valve Repair Kit (Excluding 285N) DV-285N Cartridge Valve Repair Kit Pump Repair Kit: PR-1, PR-2, PR-4(2), PR-42, PR-208 TROUBLESHOOTING CHART Symptom Possible Cause(s) Corrective Action 1. Power cord not plugged in securely. 1. Plug power cord in securely. 2. Motor switch not on. 2. Turn motor switch to ON position. 3. Pump temp. below 30°F. 3. Warm up pump to 30°F & turn motor switch on. 4. Inconsistent line voltage. 4. Line voltage must be within 10% of 115 volt. 1. Contaminated oil. 1. Change oil. 2. Oil level too low. 2. Add oil. 3. Air leak in system being evacuated. 3. Locate & repair leaks. 4. Gas ballast O-ring dirty or cut. 4. Clean or replace O-ring. 5. Pump inlet fittings missing or not tightened. 5. Replace or tighten. Oil drips from point where shaft enters the pump housing. Damaged oil seal. Replace. Pump shuts down and will not start. Thermal overload may be open. Disconnect pump from system. Wait about 15 minutes for motor to cool and turn it on again. If it cycles off again, return pump to factory for repair. Pump cycles on and off from a completely cold start and then runs smoothly. Oil backed up into cartridge and was being cleared out. Pump has not been shutdown properly. 1. Remove 1/4" cap. Pump won’t start. Pump won’t pull deep vacuum. 2. Move blank-off handle to open position. 3. Turn pump on. WARRANTY FastVac pumps are warranted against defects in materials and workmanship for 1 year. All J/B products are guaranteed when used in accordance with our directions and recommendations, and we limit this warranty to the repair, replacement, or credit at invoice price (our option) of products which in our opinion are defective due to defects in workmanship and/or materials. In no case will we allow charges for labor, expense or consequential damage. Repairs performed on items out of warranty will be invoiced on a nominal basis. Contact you wholesaler for details. Should you need further assistance, write our Home Office or contact your nearest J/B Service Center. MAIN WAREHOUSE J/B INDUSTRIES, INC. P.O. Box 1180–Dept. 85 Aurora, Illinois 60507-1180 USA E-mail: sales@jbind.com Visit our web site at: www.jbind.com Toll Free Technical Service Number 1-800-323-0811 Form 10185-308 Printed in U.S.A. 2001 J/B Industries Inc. CANADA ALLTEMP PRODUCTS CO., LTD. 827 Brock Road South Pickering, Ont., Canada L1W 3J2 Phone: (905) 831-3311 Fax: (905) 831-1864 Aurora, Illinois 60507-1180 USA 4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 4 Create Date : 2001:05:30 16:23:02 Producer : Acrobat Distiller 3.02 for Power Macintosh Subject : DV42_285Eng Creator : Adobe PageMaker 6.52 Title : DV42_285Eng Author :EXIF Metadata provided by EXIF.tools