Dorma Manual Sliding Door Tech 0Brochure 2012 Agile 150 Brochure

User Manual: Dorma-agile-150-Manual Sliding-Brochure-2012

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadDorma Manual Sliding Door Tech 0Brochure 2012 Dorma-agile-150-Manual Sliding-Brochure-2012 Brochure
Open PDF In BrowserView PDF
AGILE 150 / AGILE 150 SYNCRO
—
General information
22 – 23

Fitting modules
32 – 33

Typical assemblies
glass applications fixed
at wall + to glass
24 – 27

Component parts
34 – 36

Typical assemblies
timber applications
28
Typical assemblies
sets fixed at glass
30 – 31

20

DORMA

Accessories
37 – 41 / 75 – 78

DORMA

21

AGILE 150 / AGILE 150 SYNCRO

22

DORMA

GENERAL INFORMATION

AGILE 150 / AGILE 150 SYNCRO

GENERAL INFORMATION

AGILE 150 / AGILE 150 SYNCRO
TINY DIMENSIONS – TREMENDOUS BENEFITS
—
Superb track geometry
Height 63 mm x width
54/58/72 mm (ceiling /wall /
direct track / wall / side screen
version) – these are the telling
dimensions of the AGILE 150
sliding door system. Moreover,
all the operational equipment
has been integrated out of
sight within the track section –
despite its dainty size. The elegantly and intricately designed
profile eliminates the need for
the cover sections required by
other systems. It can be surfacetreated in all the well-known
anodised finishes and RAL
colours. Stability and torsional
stiffness constitute further
important properties inherent in
the AGILE 150 track geometry.
Minimal gap
The minimised dimensions of
the track profile and integration
of the complete operational
equipment within its section
automatically give rise to very
small clearances between the
glass and wall or glass / glass
components. Depending on the
fixing method, gaps from just
12 mm (13.5 mm glass thickness) to 18 mm (8 mm glass
thickness) are typical.

Sophisticated track roller
technology
The AGILE 150 is able to meet
a wide variety of customer
requirements - up to and including their highest demands. Just
two maintenance-free clamptype carriers can support and
transport glass panels of up to
150 kg. This is ensured by their
special track roller technology,
one which as well has proven
successful over many years in
applications involving horizontal
sliding walls (DORMA HSW
systems).
In terms of ease of operation,
AGILE is able to satisfy the
Class 3 criteria of EN 1527 –
and that means a force equivalent to just 4 % max. of the
door mass needs to be applied
in order to overcome the initial
friction and thus set the door in
motion. So there is a guarantee
that even large doors can be
operated without undue effort.
Ease of operation acc. to
EN 1527, Class 3 (example:)
Glass pane height 3,000 mm
width 1,400 mm
thickn.
12 mm
weight 128 kg
Allowed initial friction acc. to
EN 1527: 51 N
Reached initial friction with
AGILE 150: 22 N.
Reliable stop
The doors are, of course, gently
decelerated as well as being
reliably held in both their closed
and opened states by specially
developed catch-type buffers.

Elegant floor guide
The AGILE floor track offers
an impressive combination of
effective functionality and
attractive design. Its two-part
construction means it is very
easy to install, and its infinite
adjustability between 8 and
13.5 mm ensures safe and
secure guidance of the glass
panels.
One system – many solutions
The AGILE 150 offers versatility
in the truest sense of the word.
The system can be fixed at the
wall, to the ceiling or along a
lintel in either its single-panel or
double-panel configuration, and
with or without fixed side
screens. It can also be installed
with a glass overpanel. If preferred, a timber sliding panel
can be used instead of the glass
version.
No glass preparation
With clamp-type fittings, the
need to drill and cut the glass
is eliminated. Based on wideranging glass fabrication expertise, the suspension mounting
has been designed so that the
panels can be safely retained
by the clamping effect alone.
Installation is simple and
uncomplicated and the time
required – including that for
glass panel production – is
reduced to a minimum.
The variable clamp-type carriers
are able – as standard – to
engage glass thicknesses
between 8 and 13.5 mm and
are continuously adjustable.
A further advantage of the
clamp-type carrier: even after
the installation of the glass
panels, in situ vertical adjustment of +/-5 mm can be carried
out as required.

Long service life
The exceptional longevity of the
system has also been proven in
protracted tests involving more
than 100,000 operating cycles
(performed to DIN EN 1527).
And you will also find that the
AGILE 150 takes corrosion
resistance to a new level. So
there are no obstacles to its
installation and use in humid
areas. Due to chemicals (e. g.
chlorine) that may occur in the
air of swimming pools, saunas
and brine baths the fittings are
as a rule not suitable for use in
such environments. If you have
an application such as this in
mind nevertheless, we will be
pleased to advise you further.
Convenient Syncro version
The AGILE system is also available in a „Syncro“ version. In
this configuration, double-panelled sliding door sets open and
close in counter direction when
just one of the panels is operated. A virtually invisible and
thoroughly proven cable and
pulley return system ensures the
long-term availability of this
enhancement in operating convenience.
Modular system
The inherent handling ease
coupled with a thoroughly
systematic approach will
greatly facilitate your planning
work when implementing the
AGILE 150 concept. Several
set solutions for different fixing
situations are available, as are
individually tailored configurations.

Floor guide

DORMA

23

AGILE 150 / AGILE 150 SYNCRO

TYPICAL ASSEMBLIES

TYPICAL ASSEMBLIES FIXED AT WALL OR DIRECTLY AT
TRACK / WALL
—
B=Ax2

B=Ax2

35

max. 150 kg

max. 150 kg
30

30

30

30

LW

LW
A = LW + 60

A = LW + 60

Features and Data
Fixed at wall

Fixed directly at
track / wall

AGILE 150
For installations with one or two
door panels; fixed at wall or
directly at track / wall;
for 8 – 13.5 mm glass thickness,
continuously adjustable

54,5

v

H = LH + X + 63

GH = LH + X + 20

X = max.
50

max.
16,5

LH

BL = GH + 17

Max. weight of door panels
150 kg

10

LH

t

GH = LH + X + 20

X

15

Calculation of glass width
A = LW + 60 mm
(min. 500 mm)

37

63

31

37

63

58

Calculation of glass height
Fixed at wall:
GH = LH + X + 20 mm

10

t

Torque for screws in the
clamp-carriers 12 Nm

t

v

8 mm

35 mm

10 mm

33 mm

12 mm

31 mm

13,5 mm

30 mm

A
B
BL
H
GH
LH
LW
t
v

24

DORMA

=
=
=
=
=
=
=
=

Glass width
Length of track
Drilling line
Total height
Glass height
Clear opening height
Clear opening width
Glass thickness
(8 – 13,5 mm)
= Distance wall to glass

Option:
Lateral sealing to wall
see page 40
Track fixed at wall beyond a
frame on request.

AGILE 150 / AGILE 150 SYNCRO

TYPICAL ASSEMBLIES

TYPICAL ASSEMBLIES FIXED AT CEILING
—

LW

Features and Data
Fixed at ceiling
AGILE 150
For installations with one or two
door panels; fixed at ceiling
for 8 –13.5 mm glass thickness,
continuously adjustable

46
46

21

min. 60

Calculation of glass height
Fixed at ceiling:
GH = LH – 42 mm
(see drawing)
Calculation of glass width
A = LW + 60 mm
(min. 500 mm)

49

Max. weight of door panels
150 kg

14

LH

10

t

GH = LH - 42

Y

Torque for screws in the
clamp-carriers 12 Nm

A
B
GH
LH
LW
t
Y

=
=
=
=
=
=

Glass width
Length of track
Glass height
Clear opening height
Clear opening width
Glass thickness
(8 –13,5 mm)
= 54 – (12 + t)

DORMA

25

AGILE 150

TYPICAL ASSEMBLIES

TYPICAL ASSEMBLIES WITH ONE OR TWO DOOR PANELS,
WITH SIDELIGHTS
—
B=Ax2

B=Ax2

B=Ax2

A = LW / 2 + 28

A = LW + 30

A = LW / 2 + 28

4
S = A + 30

S = A + 30

S = A + 30

LW
LW

30

30

Features and Data
Version with sidelight
72

AGILE 150
For installations with one or two
door panels, with sidelights;
for 8 –13.5 mm glass thickness,
continuously adjustable

43

32

30

20

Max. weight of door panels
150 kg

X

t1

LH

Y

GH1 = LH - 42

GH2 = LH - 48

29

30

Calculation of glass height
Sliding panels:
GH1 = LH – 42 mm
(see drawing right hand)
Sidelights:
GH2 = LH – 48 mm
(see drawing left hand)
Calculation of glass width
Sliding panels:
A = LW + 30
A = LW / 2 + 28 (min. 500 mm)
(see drawing at the top)
Sidelights:
S = A + 30 mm

t1

10

5

20

t2

Torque for screws in the
clamp-carriers 12 Nm

t2

Y

13,5 mm

12 mm

12 mm

14 mm

10 mm

16 mm

8 mm

18 mm

A
=
B =
GH1 =
GH2 =
LH =
LW =
S
=
t1 =
t2
Y

Glass width
Length of track
Glass height sliding door
Glass height sidelight
Clear opening height
Clear opening width
Glass width sidelight
Glass thickness sliding
door
= Glass thickness sidelight
= 72 – (29 + t)

Option:
Lateral sealing to wall
see page 40

Note: In order to maximise the protection afforded to the glass, we recommend
that spacer 29.420 be fitted to sliding doors that move in opposite directions
(see page 40).

26

DORMA

AGILE 150

TYPICAL ASSEMBLIES

TYPICAL ASSEMBLIES FOR FIXED GLASS ELEMENTS ALIGNED
WITH SIDELIGHTS
—

70

30

30

30

Features and Data

Calculation of glass height
for fixed panels
Sidelights:
GH = LH – 48 mm

GH = Glass height
LH = Clear opening height

5

10

20

GH = LH - 48 mm

LH

20

43

AGILE 150

DORMA

27



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 8
Producer                        : GPL Ghostscript 9.06
Create Date                     : 2013:11:09 08:57:30Z
Modify Date                     : 2013:11:09 08:57:30Z
Title                           : Dorma Manual Sliding Door Tech 0Brochure 2012.pdf
Creator                         : Adobe Acrobat 9.5.1
Author                          : Ian
EXIF Metadata provided by EXIF.tools

Navigation menu