EPL Programming Guide EPL2 Manual
User Manual:
Open the PDF directly: View PDF .
Page Count: 332
Download | |
Open PDF In Browser | View PDF |
EPL Programming Guide © 2007 ZIH Corp. The copyrights in this manual and the software and/or firmware in the label printer described therein are owned by ZIH Corp. Unauthorized reproduction of this manual or the software and/or firmware in the label printer may result in imprisonment of up to one year and fines of up to $10,000 (17 U.S.C.506). Copyright violators may be subject to civil liability. This product may contain EPL™, EPL2™, ZPL®, ZPL II®, and ZebraLink™ programs; Element Energy Equalizer® Circuit; E3®; and Monotype Imaging fonts. Software © ZIH Corp. All rights reserved worldwide. ZebraLink and all product names and numbers are trademarks, and Zebra, the Zebra logo, ZPL, ZPL II, Element Energy Equalizer Circuit, and E3 Circuit are registered trademarks of ZIH Corp. All rights reserved worldwide. All other brand names, product names, or trademarks belong to their respective holders. For additional trademark information, please see “Trademarks” on the product CD. Proprietary Statement This manual contains proprietary information of Zebra Technologies Corporation and its subsidiaries (“Zebra Technologies”). It is intended solely for the information and use of parties operating and maintaining the equipment described herein. Such proprietary information may not be used, reproduced, or disclosed to any other parties for any other purpose without the express, written permission of Zebra Technologies Corporation. Product Improvements Continuous improvement of products is a policy of Zebra Technologies Corporation. All specifications and designs are subject to change without notice. Liability Disclaimer Zebra Technologies Corporation takes steps to ensure that its published Engineering specifications and manuals are correct; however, errors do occur. Zebra Technologies Corporation reserves the right to correct any such errors and disclaims liability resulting therefrom. Limitation of Liability In no event shall Zebra Technologies Corporation or anyone else involved in the creation, production, or delivery of the accompanying product (including hardware and software) be liable for any damages whatsoever (including, without limitation, consequential damages including loss of business profits, business interruption, or loss of business information) arising out of the use of, the results of use of, or inability to use such product, even if Zebra Technologies Corporation has been advised of the possibility of such damages. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Part Number: 14245L-001 A Contents About This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Who Should Use This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How This Document Is Organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Web Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . The Americas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Europe, Africa, Middle East, and India . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Asia Pacific . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Document Conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 16 17 17 17 17 17 18 1 • Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 What’s New in this Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Command Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Basic Command Syntax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Command Editor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sending Commands Directly to the Printer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sending Command Programming Files to the Printer . . . . . . . . . . . . . . . . . . . . . . . . Transferring files with the Firmware Downloader . . . . . . . . . . . . . . . . . . . . . . . . . . . . Downloading a File in the DOS Enviroment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Placing Elements in the Print Image. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Text (Fonts) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Language Character Sets (Fonts 1-5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Asian Character Sets (Fonts 8 & 9) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chinese Character Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chinese Fonts 8 & 9 Double-Byte Ideographic Characters . . . . . . . . . . . . . . . . . . . . Japanese Character Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Japanese Fonts 8 & 9 Double-Byte Ideographic Characters . . . . . . . . . . . . . . . . . . . Korean Character Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Korean Font 8 Double-Byte Characters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5/30/07 EPL Programming Guide 19 20 20 21 21 23 23 24 25 26 29 29 29 30 30 30 31 31 14245L-001 Rev. A 4 Contents Bar Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 QR Code Bar Code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Programming Sequences Affect Graphic Results. . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 2 • Printer Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Explanation of the Status Printout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Determining Printer Firmware Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Programming Mode Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Manually Setting Line Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Media Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 35 35 35 36 3 • EPL Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Memory and Command Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Command Description Memory Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 A ASCII Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Variable Data and Counter Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Data with the RTC Time & Date Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 A Simple Expressions in Data Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Asian Character Font Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 AUTOFR Automatic Form Printing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 B Bar Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 B RSS-14 Bar Code Specific Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Data with the RTC Time & Date Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 b 2D Bar Code – Aztec Specific Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 b 2D Bar Code – Aztec Mesa Specific Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 b 2D Bar Code – Data Matrix Specific Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Automatic Data Matrix Bar Code Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 b 2D Bar Code – MaxiCode Specific Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Using AIM Specified MaxiCode Data Formatting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 b 2D Bar Code – PDF417 Specific Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 PDF 417: General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 PDF 417 Symbol Geometry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Automatic PDF 417 Bar Code Generation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 b 2D Bar Code – QR Code Specific Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Cut Immediate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . dump Enable Dump Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EI Print Soft Font Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EK Delete Soft Font . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . eR User Defined Error/Status Character . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ES Store Soft Font . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14245L-001 Rev. A EPL Programming Guide 81 83 85 86 87 88 89 90 91 5/30/07 Contents f Cut Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 fB Adjust Backup Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 FE End Form Store . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 FI Print Form Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 FK Delete Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 FR Retrieve Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 FS Store Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 GG Print Graphics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 GI Print Graphics Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 GK Delete Graphics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 GM Store Graphics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 GW Direct Graphic Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 i Asian Character Spacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 I Character Set Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110 JB Disable Top Of Form Backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112 JC Disable Top Of Form Backup- All Cases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 JF Enable Top Of Form Backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114 LE Line Draw Exclusive OR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115 LO Line Draw Black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116 LS Line Draw Diagonal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .117 LW Line Draw White . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118 M Memory Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119 N Clear Image Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 o Cancel Software Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 oB Cancel Auto Bar Code Optimization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 oE Line Mode Font Substitution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 oH Macro PDF Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 oM Disable Initial Esc Sequence Feed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 oR Character Substitution (Euro) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 oW Customize Bar Code Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 O Hardware Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 OEPL1 Set Line Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Returning to Page Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 P Print . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PA Print Automatic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . q Set Label Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Q Set Form Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . r Set Double Buffer Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R Set Reference Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S Speed Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5/30/07 EPL Programming Guide 133 134 135 137 140 141 142 14245L-001 Rev. A 5 6 Contents TD Date Recall & Format Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TS Set Real Time Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TT Time Recall & Format Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . U Print Configuration (General) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UA Enable Clear Label Counter Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UB Reset Label Counter Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UE External Font Information Inquiry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UF Form Information Inquiry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UG Graphics Information Inquiry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UI Host Prompts/Codepage Inquiry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UM Codepage & Memory Inquiry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UN Disable Error Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UP Codepage & Memory Inquiry/Print . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UQ Configuration Inquiry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . US Enable Error Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UT Enable Alternate Error Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . U% Host Prompts/Motor Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . U$ Host Prompts/Battery Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V Define Variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W Windows Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xa AutoSense . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X Box Draw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Y Serial Port Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Z Print Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ? Download Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ^@ Reset Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ^default Set Printer to Factory Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ^ee Error Report - Immediate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ; Code Comment Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 159 160 161 162 164 165 166 167 168 170 171 172 173 174 4 • SGD Printer Setting Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . setvar Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . getvar Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . do Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Command Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How to Send Multiple SGD Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . appl.bootblock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . appl.name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . device.languages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.active_network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14245L-001 Rev. A EPL Programming Guide 176 176 176 177 178 178 179 180 181 182 5/30/07 Contents ip.ftp.enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.http.enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.lpd.enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.pop3.enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.pop3.password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.pop3.poll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.pop3.server_addr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.pop3.username . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.primary_network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.smtp.domain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.smtp.enable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.smtp.server_addr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.snmp.get_community_name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.snmp.set_community_name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.telnet.enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.snmp.enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.tcp.enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.udp.enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . media.printmode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . odometer.headclean . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . odometer.headnew . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . odometer.label_dot_length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . odometer.media_marker_count1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . odometer.media_marker_count2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . odometer.total_print_length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 203 204 205 206 207 208 5 • SGD Wired Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 setvar Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 getvar Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 do Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .211 Command Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212 How to Send Multiple SGD Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212 external_wired.ip.addr. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 external_wired.ip.arp_interval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214 external_wired.ip.default_addr.enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 external_wired.ip.dhcp.cid_all. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 external_wired.ip.dhcp.cid_enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217 external_wired.ip.dhcp.cid_prefix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 external_wired.ip.dhcp.cid_suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219 external_wired.ip.dhcp.cid_type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 external_wired.ip.gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 external_wired.ip.netmask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 external_wired.ip.port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 5/30/07 EPL Programming Guide 14245L-001 Rev. A 7 8 Contents external_wired.ip.protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . external_wired.ip.timeout.enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . external_wired.ip.timeout.value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . external_wired.mac_addr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internal_wired.ip.addr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internal_wired.ip.arp_interval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internal_wired.ip.default_addr.enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internal_wired.ip.dhcp.cid_all . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internal_wired.ip.dhcp.cid_enable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internal_wired.ip.dhcp.cid_prefix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internal_wired.ip.dhcp.cid_suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internal_wired.ip.dhcp.cid_type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internal_wired.ip.gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internal_wired.ip.netmask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internal_wired.ip.port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internal_wired.ip.protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internal_wired.ip.timeout.enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internal_wired.ip.timeout.value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . internal_wired.mac_addr. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 6 • SGD Wireless Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . setvar Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . getvar Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . do Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Command Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How to Send Multiple SGD Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . card.inserted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . card.mac_addr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.addr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.arp_interval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.bootp.enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.dhcp.cid_all . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.dhcp.cid_enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.dhcp.cid_prefix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.dhcp.cid_suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.dhcp.cid_type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.dhcp.enable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.gateway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.netmask. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ip.port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.adhocautomode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.adhocchannel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.associated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14245L-001 Rev. A EPL Programming Guide 244 244 244 245 246 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 5/30/07 Contents wlan.channel_mask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.essid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.firmware_version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.ip.addr. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.ip.arp_interval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.ip.default_addr.enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.ip.dhcp.cid_all. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.ip.dhcp.cid_enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.ip.dhcp.cid_prefix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.ip.dhcp.cid_suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.ip.dhcp.cid_type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.ip.gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.ip.netmask . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.ip.port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.ip.protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.ip.timeout.enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.ip.timeout.value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.keep_alive.enable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.keep_alive.timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.kerberos.kdc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.kerberos.password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.kerberos.realm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.kerberos.username. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.mac_addr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.operating_mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.preamble. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.private_key_password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.roam.interval. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.roam.signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.signal_noise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.signal_quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.signal_strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.station_name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.tx_power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.tx_rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.username . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.wep.auth_type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.wep.index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.wep.key1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.wep.key2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.wep.key3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wlan.wep.key4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5/30/07 EPL Programming Guide 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 296 297 298 299 300 301 302 303 304 305 306 307 308 14245L-001 Rev. A 9 10 Contents wlan.wep.key_format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309 wlan.wpa.psk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310 A • SGD Command Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311 Printer and Firmware Compatibility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312 B • Character References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317 Default Character Map Code Page 437 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318 Euro Character . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318 Dump Mode Character Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319 C • 2746e Print Odometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321 ELP2 Odometer Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322 oL Print Head Life Reminder Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . oLn Disable Print Head Life Reminder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . oLy Enable Print Head Life Reminder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . URH Print Head History Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . URL Read Print Odometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . URR Print Odometer Status Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323 324 325 326 327 329 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331 14245L-001 Rev. A EPL Programming Guide 5/30/07 Functional Table of Contents for EPL Commands 2D Bar Code – Aztec Mesa Specific Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 2D Bar Code – Aztec Specific Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 2D Bar Code – Data Matrix Specific Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 2D Bar Code – MaxiCode Specific Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 2D Bar Code – PDF417 Specific Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 2D Bar Code – QR Code Specific Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Adjust Backup Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 ASCII Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Asian Character Spacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 Automatic Form Printing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 AutoSense . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 Bar Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Box Draw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 Cancel Auto Bar Code Optimization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 Cancel Software Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 Character Set Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 Character Substitution (Euro) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 Clear Image Buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Code Comment Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174 Codepage & Memory Inquiry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 Codepage & Memory Inquiry/Print . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 Configuration Inquiry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Customize Bar Code Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 Cut Immediate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Cut Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Date Recall & Format Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 Define Variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 Delete Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 5/30/07 EPL Programming Guide 13979L-002 Rev. A 12 Functional Table of Contents for EPL Commands Delete Graphics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 Delete Soft Font . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Direct Graphic Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 Disable Error Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 Disable Initial Esc Sequence Feed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 Disable Print Head Life Reminder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324 Disable Top Of Form Backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 Disable Top Of Form Backup- All Cases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 Download Variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 Enable Alternate Error Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 Enable Clear Label Counter Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 Enable Dump Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Enable Error Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 Enable Print Head Life Reminder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325 Enable Top Of Form Backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 End Form Store . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Error Report - Immediate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 External Font Information Inquiry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Form Information Inquiry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 Graphics Information Inquiry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 Hardware Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 Host Prompts/Battery Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 Host Prompts/Codepage Inquiry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 Host Prompts/Motor Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 Line Draw Black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 Line Draw Diagonal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Line Draw Exclusive OR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 Line Draw White . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 Line Mode Font Substitution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 Macro PDF Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 Memory Allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Print . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 Print Automatic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 Print Configuration (General) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 Print Direction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168 Print Form Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Print Graphics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 Print Graphics Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Print Head History Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326 Print Head Life Reminder Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323 Print Odometer Status Reporting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329 Print Soft Font Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Read Print Odometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327 13979L-002 Rev. A EPL Programming Guide 5/30/07 Functional Table of Contents for EPL Commands Reset Label Counter Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 Reset Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 Retrieve Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 RSS-14 Bar Code Specific Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Serial Port Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 Set Double Buffer Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 Set Form Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 Set Label Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 Set Line Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Set Printer to Factory Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172 Set Real Time Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Set Reference Point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 Simple Expressions in Data Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Speed Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 Store Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Store Graphics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 Store Soft Font . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 Time Recall & Format Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 User Defined Error/Status Character . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 Windows Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 5/30/07 EPL Programming Guide 13979L-002 Rev. A 13 14 Functional Table of Contents for EPL Commands Notes • ___________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ 13979L-002 Rev. A EPL Programming Guide 5/30/07 About This Document This section provides you with contact information, document structure and organization, and additional reference documents. Contents Who Should Use This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . How This Document Is Organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5/30/07 EPL Programming Guide 16 16 17 18 14245L-001 Rev. A 16 About This Document Who Should Use This Document Who Should Use This Document This Guide is for programmers who are familiar working with programming languages. How This Document Is Organized The Guide is set up as follows: 14245L-001 Rev. A Section Description Introduction Provides a high-level overview about this guide and EPL. Printer Configuration Covers interpreting your printer’s configuration setup and setting basic modes. EPL Commands Contains the complete alphabetical listing of EPL commands. SGD Printer Setting Commands Provides a high-level overview of printer setting Set / Get / Do (SGD) commands. SGD Wired Commands Provides a high-level overview of the wired Set / Get / Do (SGD) commands. SGD Wireless Commands Provides a high-level overview of the wireless Set / Get / Do (SGD) commands. Appendixes The appendixes include: Character References 2746e Print Odometer SGD Command Support EPL Programming Guide 5/30/07 About This Document Contacts Contacts You can contact Zebra Technologies at the following: Web Site http://www.zebra.com Technical Support via the Internet is available 24 hours per day, 365 days per year. Go to http://www.zebra.com/support. The Americas Regional Headquarters Technical Support Customer Service Dept. Zebra Technologies International, LLC 333 Corporate Woods Parkway Vernon Hills, Illinois 60061.3109 U.S.A T: +1 847 793 2600 Toll-free +1 800 423 0422 F: +1 847 913 8766 T: +1 847 913 2259 F: +1 847 913 2578 For printers, parts, media, and ribbon, please call your distributor, or contact us. Hardware: ts1@zebra.com Software: ts3@zebra.com T: +1 877 ASK ZEBRA (275 9327) E: clientcare@zebra.com Europe, Africa, Middle East, and India Regional Headquarters Technical Support Internal Sales Dept. Zebra Technologies Europe Limited Zebra House The Valley Centre, Gordon Road High Wycombe, HP13 6EQ, UK Buckinghamshire T: +44 (0) 1494 768298 F: +44 (0) 1494 768210 Germany: Tsgermany@zebra.com France: Tsfrance@zebra.com Spain/Portugal: Tsspain@zebra.com All other areas: Tseurope@zebra.com For printers, parts, media, and ribbon, please call your distributor, or contact us. Regional Headquarters Technical Support Customer Service Zebra Technologies Asia Pacific, LLC 120 Robinson Road #06-01 Parakou Building Singapore 068913 T: +65 6858 0722 F: +65 6885 0838 T: +65 6858 0722 F: +65 6885 0838 E: China: tschina@zebra.com All other areas: tsasiapacific@zebra.com For printers, parts, media, and ribbon, please call your distributor, or contact us. T: +44 (0)1494 472872 F: +44 (0) 1494 450103 T: +44 (0) 1494 768316 F: +44 (0) 1494 768244 E: cseurope@zebra.com Asia Pacific 5/30/07 EPL Programming Guide T: +65 6858 0722 F: +65 6858 0836 14245L-001 Rev. A 17 18 About This Document Document Conventions Document Conventions The following conventions are used throughout this document to convey certain information. Alternate Color (online only) Cross-references contain hot links to other sections in this guide. If you are viewing this guide online in .pdf format, you can click the cross-reference (blue text) to jump directly to its location. Command Line Examples Command line examples appear in Courier New font. For example, type ZTools to get to the Post-Install scripts in the bin directory. Files and Directories File names and directories appear in Courier New font. For example, the Zebra.tar file and the /root directory. Icons Used Important • Advises you of information that is essential to complete a task. Note • Indicates neutral or positive information that emphasizes or supplements important points of the main text. Example • Provides an example, often a scenario, to better clarify a section of text. 14245L-001 Rev. A EPL Programming Guide 5/30/07 1 Introduction This section contains information about the basic features, command syntax, and terminology of the EPL2 programming language for Zebra's desktop printers with flash memory architecture. These printers incorporate common programming code sets and architectural features. The primary operating mode for the printer is EPL2, a page description language. EPL2 is an ideal language for your labeling and bar code requirements. To speed printing, it is designed to assemble all of the elements of the label prior to printing. EPL2 is versatile and capable of printing graphics, a wide range media, and bar codes. Some direct thermal printer models also include a legacy printer compatibility mode, Line Mode. Line Mode supports our early model EPL programming language - ELP1. A separate manual is provided for Line Mode printing. See the printer’s Software and Documentation CD for the programmer’s manual that applies to your printer, or visit our web site at: www.zebra.com What’s New in this Document Newly added to this programming guide are Set/Get/Do (SGD) commands. SGD commands are commands that allow you to configure printers and have the printer perform the specified function immediately after receiving the command. See SGD Command Support on page 311 to determine if these commands are compatible with your printer/firmware combination. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 20 Introduction Command Conventions The manual uses the following typographic conventions to describe commands. Example Description A Commands (case sensitive) p1,p2,p3 Required parameters [p,p,p] Optional parameters {Choice 1|Choice2} Indicates a mandatory choice between two or more items. You must include one of the items unless all of the items are also enclosed in square brackets. “NAME” The name of a form or graphic in double quote marks. “DATA” The text or bar code data in double quote marks. The backslash (\) character designates the following character is a literal and will encode into the data field. To Print Enter into data field " \" “Company” \”Company\” \ \\ \code\ \\code\\ An ASCII text field that will be transmitted to the host (via the serial interface) each time this command is executed. “PROMPT” Important • All commands and alpha character command parameters are case sensitive! Basic Command Syntax Each command consists of one or two ASCII (case sensitive) alpha characters to identify the specific command desired. Some commands require one or more additional parameters to supply the printer with sufficient information to complete the command. Refer to Figure 1- for the basic command syntax. Figure 1 • Basic Command Syntax Command Name WRITE TEXT A p1,p2,p3,p4,p5,p6,p7,"DATA" Command 14245L-001 Rev. A Parameters Command Specific Data EPL Programming Guide 5/30/07 Introduction Each command line must be terminated with a Line Feed (LF) character (Dec. 10). Most PC based systems send CR/LF when the Enter key is pressed. The Carriage Return (CR) character is ignored by the printer and cannot be used in place of LF. Command Editor One method to create command files is through an ASCII-based text editor. In the DOS environment, MS-DOS EDIT or BRIEF are good choices. In the Windows environment, TextPad® for Windows is a good choice and is available for download of a free evaluation copy at: www.textpad.com Sending Commands Directly to the Printer The easiest method available in the Microsoft Windows environment is to use the Zebra Universal Printer Driver (ZUD) for sending single EPL Page Mode commands to the printer. This method supports all of the printer interfaces. If you have successfully installed the printer and its printer driver, you can use the following procedure: 1. Find and open your printer in the Windows Start > Settings > Printers and Faxes selection. 2. In the newly opened Printers and Faxes window, left click a single time to select your printer and then right click to open a menu window. 3. Click on the Properties menu selection. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 21 22 Introduction 4. Click on the Printer Tab. Printer Tab Click to expand (Advanced) 5. Click on the plus sign in front of Advanced to expand the selections available. 6. Click on the Tools button. 7. Click in Direct Command for Printer and begin typing EPL Page Mode printer commands. Press the Send button to send a single command. Do not use the Enter key on the key board; it is the same thing as pressing the OK button (to exit the Tools window). 14245L-001 Rev. A EPL Programming Guide 5/30/07 Introduction Sending Command Programming Files to the Printer Page Mode programming files can be sent to the printer from Windows operating systems by using the Zebra Firmware Downloader (found on the user’s CD or at www.zebra.com. In the DOS enviroment, use the Copy command at the command prompt. The easiest method is to use the Zebra Firmware Downloader to transfer files to the printer. Transferring files with the Firmware Downloader 1. Install the printer. Verify communication is working properly by printing a Printer Configuration or Test using the printer's driver properties window. See Sending Commands Directly to the Printer on page 21 for more details. 2. Install the Zebra Firmware Downloader on your system by selecting Start > Programs > Zebra > Firmware Downloader. 3. From the Printer menu, select Auto-Detect. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 23 24 Introduction 4. Click on your Zebra printer to select the printer for download. 5. From the File menu, choose Select Firmware File. Use the Browser window to select your command file for download to your printer. Downloading a File in the DOS Enviroment To execute the file, use the editor’s print command or from the DOS prompt, use the COPY command to send the file directly to the printer. This method does not support USB or Ethernet printer interfaces. An example of the use of the COPY command is: COPY “FILENAME.EXT” LPT1 or COPY FILENAME.EXT” COM1 For more information on the use of the COPY command, refer to your DOS software manual. Configure the COM port to match the printer’s serial port setting (typically set to defaults). See the Y command in section 2 for details. 14245L-001 Rev. A EPL Programming Guide 5/30/07 Introduction Placing Elements in the Print Image Image elements are located in the image print buffer on an X-Y grid expressed in dots. The X value represents the width and the Y value represents the height of the grid. The point of origin (the starting point) for a non-rotated object is the upper left corner. As an object rotates, the point of origin rotates with the object. These image buffer properties are depicted graphically in the following illustration. Figure 2 • Sample Format REPUT YBYJT 7H[W 7H[W 1PJOUPG 0SJHJOGPS 5FYU0CKFDU 7H[W ZBYJT 1PJOUPG 0SJHJOGPS #BS$PEF0CKFDU %JSFDUJPO0G'FFE 1PJOUPG 0SJHJOGPS 5FYU0CKFDU 3PUBUFE¡ 2 EPUT 1PJOUPG 0SJHJOGPS 5FYU0CKFDU 3PUBUFE¡ The minimum non-printing margin on all edges of the label is 1 mm. Printing closer than 1 mm to the top or bottom edge of the label may cause the printer to advance unwanted labels or cause the printer to go into error condition. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 25 26 Introduction Text (Fonts) The standard EPL2 printer has five (1-5) resident mono-spaced dot fonts. Fonts A-Z and a-z (upper and lower case alpha characters) are reserved for downloading soft fonts. Figure 3 • Character spacing First Character of Text String Reference Point 12 D o t s 8 Dots Character Width Inter-character Space (actually white dots) Control text height (in horizontal dots) and width (in vertical dots) with the horizontal and vertical multipliers. The text is oriented first and then the A command’s font multipliers and font rotation are applied. Note • The reference point of the first character in a text string is not affected by the font size multiplier values. 14245L-001 Rev. A EPL Programming Guide 5/30/07 Introduction The standard Latin font (1-5) and soft font characters are dot mapped differently than the Asian font (8 & 9) characters. The Asian character does not have a built-in inter-character gap. The Latin characters include a single dot border around each character. Note: 203 dpi characters shown as example Total Character Width 8 Dots Character Width Total Character Width 24 Dots 12 D o t s 24 Inter-character Space (actually white dots) D o t s Fonts 1 (8 x 12 dots) Font 8 (24 x 24 dots) With the (A) command’s horizontal multiplier (p5) set to 2, the inter-character spacing will look like the following example. 2 times 2 times 2 times 5/30/07 EPL Programming Guide 2 times 14245L-001 Rev. A 27 28 Introduction Text is placed into the image buffer. See the following example. g x axis y axis (0,0) Point of Origin for Text Object Horizontal Dots Text - No Size Multipliers Point of Origin for V Text Object e Rotated 90° r t i c a l 2x Horizontal Multiplier Point of Origin for Text Object D o t s 2x Vertical Multiplier Point of Origin for Text Object Direction Of Feed Point of Origin for Text Object Rotated 270° The Asian fonts (8-9) can print character strings oriented from top to bottom (p3 values 4–7), as well as the standard Latin word orientation from left to right (p3 values 0–3). The characters will print in the sequence that they are entered into the (A) command’s data field. x axis y axis (0,0) Point of Origin for Text Object (p =5) Horizontal Dots Text - No Size Multipliers 2x Horizontal Multiplier Point of Origin for Text Object (p =5) D o t s 2x Vertical Multiplier Point of Origin for Text Object (p =5) V e r t i c a l Point of Origin for Text Object Rotated 90° (p =6) Direction Of Feed Point of Origin for Text Object Rotated 270° (p =4) 14245L-001 Rev. A EPL Programming Guide 5/30/07 Introduction Language Character Sets (Fonts 1-5) The Latin-based language and Greek character support is controlled and enabled with the I command on page 110. The default language set is the English DOS codepage 437. Characters, such as the Euro symbol, can be substituted using the oR command on page 127. Asian Character Sets (Fonts 8 & 9) The Page Mode EPL2 programming language supports up to two (2) font sets of a single Asian language as well as the standard EPL2 Latin (Multilingual) fonts 1-5 and downloadable soft fonts (A-Z and a-z). Asian language support is an optional feature and requires a special version of the printer (PCBA) to support the large Asian character sets. The flash-based printers support up to five different Asian language character (ideogram) sets. See the A command on page 41 for the detailed list of of fonts. For Asian language firmware updates, publications, and support options, see www.zebra.com. All fonts can be expanded both horizontally and vertically. The Asian fonts can also be printed from top to bottom or in the Latin character orientation from left to right. The Asian printers support the standard Latin fonts with the single character map code page 437 for all five (5) fonts. The Asian characters are 16 bit (or double-byte) mapped characters. The printed Asian character is dependent on the double-byte ASCII values. The Latin (English, etc.) font sets are 8 bits per (or single-byte) ASCII character maps. Note • Only one (1) Asian language is supported by a printer. Each Asian language (character set) is a separate printer firmware version. Asian printers with flash firmware can be reprogrammed for a different Asian language, but we do not recommend this for normal use. Chinese Character Set The printer automatically recognizes single-byte characters and double-byte characters. The single-byte font characters are mapped to hexadecimal address range 00 to 7F hex (0-127 decimal) for 203 dpi printers and 00 to FF hex (0-255 decimal) for 300 dpi printers. The double-byte font characters are mapped to hexadecimal address range A1A0 to F7FF hex. First byte, 161 (A1h) and second byte 160 (A0h) to first byte, 247 (F7h) and second byte, 255 (FFh) is the decimal, grouped byte range. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 29 30 Introduction Chinese Fonts 8 & 9 Double-Byte Ideographic Characters The Chinese ideographic font characters are mapped to double-byte hexadecimal address range A1A0 to F7FFhex. See the following pages for the codepage character mappings. • Simplified — 203 dpi printers • Simplified — 300 dpi printers • Traditional — 300 dpi printers Japanese Character Sets The printer automatically recognizes single-byte characters and double-byte characters in the Shift-JIS codepage. The single-byte font characters are mapped to hexadecimal address range 00 to 7F hex (0-127 decimal) for 203 dpi printers and 00 to FF hex (0-255 decimal) for 300 dpi printers. The double-byte font characters are mapped to the hexadecimal address ranges in the following table. Codepage Reference From To Range 1st byte 2nd byte 1st byte 2nd byte JIS 2120-7424 33 (21h) 32 (20h) 116 (74h) 36 (24h) Shift-JIS 8140-9FFC 129(81h) 64 (40h) 159 (9Fh) 252 (FCh) E040-EAA4 224 (E0h) 64 (40h) 234 (EAh) 164 (A4h) Japanese Fonts 8 & 9 Double-Byte Ideographic Characters The Japanese ideographic font characters are mapped to double-byte hexadecimal addresses. See the following electronic document (Acrobat format) pages for codepage character maps. • 203 dpi printers — JIS • 203 dpi printers — Shift JIS • 300 dpi printers — JIS • 300 dpi printers — Shift JIS 14245L-001 Rev. A EPL Programming Guide 5/30/07 Introduction Korean Character Sets The printer automatically recognizes single-byte characters and double-byte characters. The single-byte font characters are mapped to hexadecimal address range 00 to 7F hex (0-127 decimal). The double-byte font characters are mapped to hexadecimal address range A1A0 to F0FF hex. First byte, 161 (A1h) and second byte 160 (A0h) to first byte, 253 (FDh) and second byte, 255 (FFh) is the decimal, grouped byte range. Korean Font 8 Double-Byte Characters The Korean font characters are mapped to double-byte hexadecimal address range A1A0 to FDFF hex. See the following pages for the character maps. • 203 dpi printers • 300 dpi printers Bar Codes All bar codes supported by the EPL2 language have associated industry specifications that the programmer should be aware of and adhere to. The programmer needs to consider bar code features and requirements when choosing and using a bar code for different applications. Some of the features and requirements that need consideration are listed below: • Data used by the application are per the bar code specification (numbers only, alphanumeric, alphanumeric and special characters, etc.). • Minimum and maximum number of characters allowed or required per bar code. • Density or magnification of a given bar code type. • White area required around bar codes (the “Quiet Zone”). • The bar code must print within the image buffer (printable area of the label). 5/30/07 EPL Programming Guide 14245L-001 Rev. A 31 32 Introduction Note • Bar Code Orientation Tip: To help ensure that generated bar codes are readable by the widest variety of bar code readers, print bar codes in the “Picket Fence” orientation versus the “Ladder” orientation. )PSJ[POUBM%PUT YBYJT ZBYJT )FJHIUPG #BS$PEF )FJHIUPG #BS$PEF 7 F S U J D B M % P U T 1JDLFU'FODF 0SJFOUBUJPO -BEEFS 0SJFOUBUJPO %JSFDUJPO0G'FFE QR Code Bar Code The QR Code bar code is only offered with Japanese Character bar code printer configurations. Programming Sequences Affect Graphic Results Graphic elements can interact and the resultant image can be affected by other commands. Structure command sequences to reduce the chances of unexpected print results. The printer will process lines, text, boxes, and most bar codes in command sequence. The printer then processes the printer control processes, counters, variable data, Postnet, and then graphics last. 14245L-001 Rev. A EPL Programming Guide 5/30/07 2 Printer Configuration This section covers interpreting your printer’s configuration setup and setting basic modes. To determine your printer’s configuration and operating mode, do one of the following: • Print a configuration label using the control panel. • Print a configuration label by sending the U command to the printer. • Use the AutoSense feature. The primary functions that AutoSense provides are: • adjustment of the Media Sensor in the printer to the media in use • the programming mode — page (EPL2) or line (EPL1 emulation) mode. • the printer’s serial interface settings • the printer’s configuration status including printer options Note • The AutoSense feature and Line Mode are not available for all printer models. Refer to your printer’s user guide for specific feature information. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 34 Printer Configuration Explanation of the Status Printout Depending on your printer model, your dump mode label will look similar to one of those shown below. See Figure 9 on page 319 for additional information. Figure 4 • Dump Mode Print Samples UKQ1935 V4.59 Serial port:96,N,8,1 Page Mode Image buffer size:0245K Fmem:0 (bytes) Gmem:0 Emem:29600 Available: 100959 I8,0,001 rY JF WY S4 D00 R0,0 ZT UN q832 Q1022,029 Option:d,Ff oEw,x,y,z 16 23 31 Cover: T=143, C=166 Date: 10-05-94 Time:01:00:00 Now in DUMP MODE Press Feed to exit Dump Mode Print Sample 14245L-001 Rev. A A. Printer I.D. code number and firmware version. B. Serial port configuration. C. Programming Mode Print head resolution D. Print head test pattern. E. Amount of memory available for the Image buffer. F. Amount of memory used and memory available for Form storage. G. Amount of memory used and memory available for Graphics storage. H. Amount of memory used and memory available for Soft fonts. I. Total free memory available for Forms, Fonts, or Graphics J. Currently selected Character Set (I) and Image Buffer mode setting (r). rY = Double Buffering Enabled rN = Double Buffering Disabled K. Currently selected Print Speed (S), Heat Density (D), Reference Point (R), Print Orientation (Z) and Error Status (U). L. Currently selected Form Width (q) and Length (Q). M. Current Hardware and Software Option status. N. Current AutoSense Through (Web/Gap) Sensor values. The three numbers represent; 1. Backing Transparent point 2. Set point 3. Label Transparent point. O. Head Up (Open) Sensor settings P. Current Date and Time set in Real Time Clock. Thess values will only be displayed if your printer is equipped with the Real Time Clock feature. Q. Current Dump Mode Status. EPL Programming Guide 5/30/07 Printer Configuration Determining Printer Firmware Version The printer version numbers are a code used to document product function and the feature support level of the printer. The latest firmware version and updates can be obtained from our web site. Programming Mode Configuration Flash based printers are, by default, configured for Page (EPL2) mode operations. The operator must convert the printer to Line Mode prior to the initial use of Line Mode. This is done via a hardware select procedure with the Feed button during printer power-up. See the OEPL1 command on page 132 for details on switching between line and page modes via programming. The following direct thermal printers support Line Mode (EPL1 emulation): • LP2824 • LP2844 Note • The Line Mode (and Page Mode) configuration setting is retained after reset has been issued or power has been cycled. Manually Setting Line Mode The Line Mode capable printer utilizes the Feed button during printer power-up to toggle between the printer personality modes, Line and Page (EPL2). 1. With printer power off, press and hold the Feed button while turning on the printer, and then release the button when the LED starts blinking red. 2. When the indicator LED starts flashing green, immediately press and hold the Feed button. 3. Release the Feed button when the LED turns a steady amber (orange) color. 4. Verify printer personality with Dump Mode printout: Line Mode or Page Mode (EPL2). 5. Press the Feed button to exit the Dump Mode. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 35 36 Printer Configuration Media Detection Media detection in EPL2 printers is a combination of programming and printer media sensing. The Q (Set Form Length) and O (Option) commands program the media detection method. The user must configure the printer for the media type and the (programmed) form or label in use. The printer can detect the beginning and end of the printable area on the media by one of three methods: gap, notch (hole), or black line. The gap method detects the difference in optical density of a label on a liner from the liner only with the transmissive (gap) sensor. The notch method uses the transmissive sensor to detect a hole in the media (gap-less labels or tag stock). The black line method uses the reflective sensor to detect a preprinted black line on the media back (for gap-less labels or tag stock). Printing on continuous media requires programming to control media positioning. EPL2 printers also support a “Label Dispense” mode as a printer configuration option (for most models). The printers use a “Label Taken” sensor to detect the removal of a label. One or more of these sensors may require user adjustment or configuration for proper operation. All EPL2 printers have an AutoSense feature to optimize label and label gap detection by the transmissive (gap) sensor. See the printer’s user manual for printer specific sensor adjustment control. 14245L-001 Rev. A EPL Programming Guide 5/30/07 3 EPL Commands This section contains a complete alphabetical listing of all EPL commands. Memory and Command Usage The printer stores configuration settings, fonts, graphics (logos) and label form files into printer memory. The Command Reference includes a Memory column with the following terms: • Image commands are use to assemble the printed label image in the print image buffer. • Form commands are only used within forms. • Session commands place the configuration setting in temporary RAM memory. The setting reverts to the printer default when the printer has power cycled or is reset. • Stored memory commands will check for differences with the existing command setting prior to validating a memory write operation. The printer's non-volatile "flash" memory has a limited number of write cycles (100,000 plus). • Writes to memory commands are commands that do not check to see if a setting, file, font, character or graphic is already present or if that condition is already set. These commands are rarely used in forms except as a printer initialization and function oriented configuration. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 38 EPL Commands Command Description Memory Page Command Description Memory Page 14245L-001 Rev. A Command Description Memory Page A ASCII Text Image 41 AUTOFR Automatic Form Printing Form 48 B Bar Code Image 50 B RSS-14 Bar Code Image 56 b Aztec Image 60 Aztec Mesa Image 64 Data Matrix Image 66 MaxiCode Image 70 PDF417 Image 74 QR Code Image 81 C Counter Form 83 C Cut Immediate — 85 D Density Stored 86 dump Enable Dump Mode — 87 EI Print Soft Font Info. — 88 EK Delete Soft Font Writes 89 eR User Definable Error Response Writes 90 ES Store Soft Font Writes 91 f Cut Position Stored 96 fB Adjust Backup Position Writes 97 FE End Form Store Writes 98 FI Print Form Info. — 99 FK Delete Form Writes 100 FR Retrieve Form — 101 FS Store Form Writes 102 GG Retrieve Graphics Image 103 GI Print Graphics Info. — 104 GK Delete Graphic Writes 105 GM Store Graphic Writes 106 GW Direct Graphic Write Image 108 i Asian Character Spacing Stored 109 I Character Set Selection Stored 110 JB Disable Top Of Form Backup Stored 112 JC Disable Top Of Form Backup - All Cases Stored 113 EPL Programming Guide 5/30/07 EPL Commands Command Description Memory Page 5/30/07 Command Description Memory Page JF Enable Top Of Form Backup Stored 114 LE Line Draw Exclusive OR Image 115 LO Line Draw Black Image 116 LS Line Draw Diagonal Image 117 LW Line Draw White Image 118 M Memory Allocation Writes 119 N Clear Image Buffer Image 120 o Cancel Customized Settings Writes 121 oB Cancel Customize Bar Code Writes 122 oE Line Mode Font Substitution Writes 123 oH Macro PDF Offset Image 124 oM Disable Initial Esc Sequence Feed Stored 126 oR Character Substitution (Euro) Writes 127 oW Customize Bar Code Parameters Writes 128 O Options Select Stored 130 OEPL1 Set Line Mode Writes 132 P Print — 133 PA Print Automatic Form 134 q Set Form Width Stored 135 Q Set Form Length Transmissive (Gap) Sensor Black Line Sensor| Continuous Stock Stored 137 r Set Double Buffer Mode Stored 140 R Set Reference Point Stored 141 S Speed Select Stored 142 T Define Date Layout (& Print Date) Writes 143 TS Set Real Time Clock Stored 144 TT Define Time Layout (& Print Time) Writes 145 U Print Configuration — 146 UA Enable Clear Label Counter Mode Session 147 UB Reset Label Counter Mode Writes 148 UE External Font Information Inquiry — 149 UF Form Information Inquiry — 150 UG Graphic Information Inquiry — 151 UI Host Prompts/Codepage Inquiry Session 152 EPL Programming Guide 14245L-001 Rev. A 39 40 EPL Commands Command Description Memory Page 14245L-001 Rev. A Command Description Memory Page UM Codepage & Memory Inquiry Session 153 UN Disable Error Reporting Stored 154 UP Codepage & Memory Inquiry/Print — 155 UQ Configuration Inquiry — 156 US Enable Error Reporting Stored 157 UT Enable Alternate Error Reporting Stored 159 U% Host Prompts/Battery Inquiry — 160 U$ Host Prompts/Motor Temperature Inquiry — 161 V Define Variable Form 162 W Windows Mode Stored 164 xa Sense Media Writes 165 X Box Draw Image 166 Y Serial Port Setup Stored 167 Z Print Direction Stored 168 ? Download Variables Form 170 ^@ Reset Printer — 171 ^default Set Printer to Factory Defaults Writes 172 ^ee Status Report - Immediate — 173 ; Code Comment Line Form 174 EPL Programming Guide 5/30/07 EPL Commands A A ASCII Text Description Renders an ASCII text string to the image print buffer. See Text (Fonts) on page 26 for discussion on text handling in Page Mode programming. Asian language EPL2 Page Mode printers have special firmware and printer (PCBA) memory order options to support the large Asian character (ideogram) sets. The Latin (English, etc.) font sets (1-5, a-z, and A-Z) are single-byte (8 bits per byte) ASCII character maps. The Asian characters are double-byte mapped characters. The printed Asian character is dependent on the double-byte ASCII values. Syntax Ap1,p2,p3,p4,p5,p6,p7,”DATA” Parameters This table identifies the parameters for this format: Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. p3 = Rotation Characters are organized vertically from left to right and then rotated to print. Accepted Values: 0 = normal (no rotation) 1 = 90 degrees 2 = 180 degrees 3 = 270 degrees Rotation for Asian Printers Only Characters are organized horizontally from top to bottom and then rotated to print. Asian printers support both horizontal and vertical character rotation. Accepted Values: (Asian Printers Only) 4 = normal (no rotation) 5 = 90 degrees 6 = 180 degrees 7 = 270 degrees 5/30/07 EPL Programming Guide 14245L-001 Rev. A 41 42 EPL Commands A Parameters Details p4 = Font selection Description Value 203 dpi 300 dpi 1 20.3 cpi, 6 pts, (8 x 12 dots) 25 cpi, 4 pts, (12 x 20 dots) 2 16.9 cpi, 7 pts, (10 x 16 dots) 18.75 cpi, 6 pts, (16 x 28 dots) 3 14.5 cpi, 10 pts, (12 x 20 dots) 15 cpi, 8 pts, (20 x 36 dots) 4 12.7 cpi, 12 pts, (14 x 24 dots) 12.5 cpi, 10 pts, (24 x 44 dots) 5 5.6 cpi, 24 pts, (32 x 48 dots) 6.25 cpi, 21 pts, (48 x 80 dots) A-Z a-z Reserved for Soft Font storage. Reserved for printer driver support for storage of user-selected Soft Fonts. 6 Numeric Only (14 x 19 dots) Numeric Only (14 x 19 dots) 7 Numeric Only (14 x 19 dots) Numeric Only (14 x 19 dots) Asian Printers 8 Simplified Chinese, Japanese, Korean 203 dpi fonts : 24 x 24 dots 300 dpi Double-byte fonts: 36 x 36 dots 300 dpi Single-byte fonts: 24 x 26 dots 9 Traditional Chinese, Japanese 300 dpi Double-byte fonts: 36 x 36 dots 300 dpi Single-byte fonts: 24 x 26 dots Korean - Reserved Fonts 1-5 are fixed pitch. Asian language option printers support a single language with fonts 8 and 9. • • p5 = Horizontal multiplier Horizontal multiplier expands the text horizontally. Accepted Values: 1–6, 8 p6 = Vertical multiplier Vertical multiplier expands the text vertically. Accepted Values: 1–9 p7 = Reverse image Accepted Values: N = normal R = reverse image DATA = Fixed data field Fixed data field The backslash (\) character designates the following character is a literal and will encode into the data field. 14245L-001 Rev. A To Print Enter into data field " \" “Company” \”Company\” \ \\ \code\ \\code\\ EPL Programming Guide 5/30/07 EPL Commands A Example • In this example, font 5 only supports upper case characters. Refer to Appendix B, Character References, for a complete listing of available fonts and character sets supported. N↵ A50,0,0,1,1,1,N,"Example 1"↵ A50,50,0,2,1,1,N,"Example 2"↵ A50,100,0,3,1,1,N,"Example 3"↵ A50,150,0,4,1,1,N,"Example 4"↵ A50,200,0,5,1,1,N,"EXAMPLE 5"↵ A50,300,0,3,2,2,R,"Example 6"↵ P1↵ The code above will produce this label: Note • Use the LE command to create reverse print text instead of the “R” in the A command parameter p7. This is the recommend method because it provides the best size, position, and centering of the black line (rectangle) bordering the reversed text. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 43 44 EPL Commands A Special JIS Code Page Programming Considerations The JIS keyboard technique utilizes double-byte data characters. Each byte of the of the double-byte character can be represented by one of the lower 128 ASCII data characters (20 through 7F hexadecimal). The printer uses a Shift-& to recognize a JIS character text data string. Once the JIS text mode has been set with the Shift-&, the JIS text mode remains in effect until the text data string is terminated. Shift = 1C hexadecimal or 28 decimal & (Ampersand) = 26 hexadecimal or 38 decimal If any text data string contains the ASCII character values for the quote (”) character, then it must be proceeded by a backslash. ” (quote) = 22 hexadecimal or 34 decimal \ (backslash) = C5 hexadecimal or 92 decimal Note • Enter the “Shift” character with the number pad on the standard 101 key PC keyboard. With the Number Lock on, type 028 on the number pad while holding the ALT key down. This is a standard method of entering ASCII characters not directly supported by a keyboard. When using the JIS, if the last character in a string of characters is a backslash (\), then the Shift character followed by any character is required to exit the JIS character mode. Example • A50,0,0,8,1,1,N,"Example JIS &5\ ." In this example: • represents the ASCII value 28 decimal. • & enters JIS text mode. • . exits JIS text mode • (returns to Shift JIS text mode). Variable Data and Counter Functions The “Data” field can be replaced by or combined with the following commands: • Vnn= Prints the contents of variable “nn” at this position where nn is a 2 digit number from 00 to 99. For more information, refer to the V command on page 162. • Cn= Prints the contents of counter “n” at this position where n is a one digit number from 0 to 9. For more information, refer to the C command on page 83. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands A Example • A50,0,0,1,1,1,N,"DATA"↵ A50,50,0,2,1,1,N,V01↵ A50,100,0,3,1,1,N,C1↵ A50,100,0,3,1,1,N,C1+2↵ : Writes Text : Writes contents of variable 01 : Writes contents of counter 1 : Writes contents of counter 1 plus 2 Data with the RTC Time & Date Functions The “Data” field can be replaced by or combined with the following variables: • TT = Prints the current time at this position in the predefined format. See the TT command for format selection. This variable is available only if the printer Time & Date option is installed. • TD = Prints the current date at this position in the predefined format. See the TD command for format selection. This variable is available only if the printer Time & Date option is installed. Example • A50,150,0,4,1,1,N,TT↵ A50,200,0,5,1,1,N,TD↵ : Writes current time : Writes current date or a combination of several options: A50,300,0,3,2,2,R,"Deluxe"V01C2"Combo"TDV01TT↵ : Writes the text “Deluxe” followed by the contents of variable 01 followed by the contents of counter 2 followed by the text “Combo” followed by the current date followed by the contents of variable 01 followed by the current time. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 45 46 EPL Commands A A Simple Expressions in Data Fields An advanced function of the A command allows addition and subtraction to be performed on constant and variable values in flash printers. Syntax Ap1,p2,p3,p4,p5,p6,p7,”DATA”[p8p9p10…] Parameters This table identifies the parameters for this format: 14245L-001 Rev. A Parameters Details p1 through p7, ”DATA” See the first page of the A command on page 41. p8 = Required variable data field number Must be a variable data field number, such as V00, V01, and so forth. p9 = Required operator Accepted Values: + or – p10 = Required Variable data field number or constant value. Accepted Values: Constant = 0 to 2147483647 Variable = 0 to 2147483647 Result = -2147483648 to 2147483647 • The expression must start with a variable field. • The character field length defined for the first variable in the expression will be used to format the result. If the result is of a greater length than the defined character length, then the result field will contain ‘X’s. • A syntax error will be generated during form storage if the constant value is too large. • If an error occurs during the evaluation of the expression, the resultant field will be filled with ‘X’s. EPL Programming Guide 5/30/07 EPL Commands A Example • FK"1"↵ FK"1"↵ FS"1"↵ V00,10,N,"Enter current mileage"↵ A100,100,0,4,1,1,N,"Current mileage is “V00" miles.”↵ A100,200,0,4,1,1,N,"Change oil at “V00+3000" miles.”↵ FE↵ ↵ FK"2"↵ FK"2"↵ FS"2"↵ V00,10,N,"Enter current mileage."↵ V01,10,N,"Enter interval mileage."↵ A100,100,0,4,1,1,N,"Current mileage is “V00" miles.”↵ A100,200,0,4,1,1,N,"Mileage interval is “V01" miles.”↵ A100,200,0,4,1,1,N,"Change oil at “V00+V01" miles.”↵ FE↵ ↵ FK"3"↵ FK"3"↵ FS"3"↵ V00,10,N,"Enter value 1."↵ V01,10,N,"Enter value 2."↵ V02,10,N,"Enter value 3."↵ A100,200,0,4,1,1,N,"Answer: “V01+123+V00-10-V02↵ FE↵ Asian Character Font Sets Asian language support is an optional feature and requires a special version of the printer (PCBA) to support the large Asian character sets. The Asian character maps and special features of the A command that support the character sets can be found starting on page 29. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 47 48 EPL Commands AUTOFR AUTOFR Automatic Form Printing Description This special form process allows you to detach the printer from the computer and print in a standalone mode. The EPL2 printer reserves the form name AUTOFR to allow the printer to automatically start a form when the printer is initialized power-up. This feature can be used in many ways, including the following: • Feed a single label in peel mode and print multiple labels set to the number of labels on the roll. • Have a form with a variable and enter the variable with a scanner, terminal, weight scale, circuit analyzer or any other device capable of sending ASCII character data. Mobile printers, such as the TR 220, ignore this command. Syntax FK"AUTOFR" or FS"AUTOFR" Parameters There are no parameters for this command. Example • Download a form to the printer with the name AUTOFR. ↵ : Line Feed to initialize the printer FK"AUTOFR"↵ : Form Kill (delete any existing AUTOFR) FS"AUTOFR"↵ : Form Save (save file from here to FE at the bottom) : Variable field definition V00,8,L,""↵ Q254,20↵ : Label height followed by gap width S2↵ : Speed (2ips) D7↵ : Density setting ZB↵ : Print direction (ZT flips it 180 degrees) A340,20,0,4,1,2,N,"QUANTITY"↵: Fixed text line B265,75,0,3,2,4,101,B,V00↵ : Bar code definition PA1↵ : Print 1 label Automatically * FE↵ : Form End (Line Feed) Note • AUTOFR treats any incoming data as a variable intended for printing. If you send the printer a memory partition command, the label will print, and if you send a delete command, the label will also print. So, while you are testing AUTOFR it is best to use another name for the form. Once you are satisfied with the form, rename it AUTOFR before you download it. There is no need to specify a file extension. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands AUTOFR Isolating Data from the Input Device Place the printer in the diagnostic dump mode and send from your data input device. • All characters the device sends will be printed on the label. • If nothing prints, nothing is arriving; check pin-outs and serial settings. Disabling AUTOFR Send a XOFF data character (13 hex. or ASCII 19) or a NUL(00 hex. or ASCII 0) to the printer. The form may now be deleted from the printer. Removing AUTOFR The programmer must send a Delete Form - FK command to the printer after disabling AUTOFR. FK"AUTOFR"↵ FK"AUTOFR"↵ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 49 50 EPL Commands B B Bar Code Description Use this command to print standard bar codes. Syntax Bp1,p2,p3,p4,p5,p6,p7,p8,”DATA” Parameters This table identifies the parameters for this format: 14245L-001 Rev. A Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. p3 = Rotation Accepted Values: 0 = normal (no rotation) 1 = 90 degrees 2 = 180 degrees 3 = 270 degrees p4 = Bar Code selection. See Table 1, Bar Codes on page 51 for more information. p5 = Narrow bar width Narrow bar width in dots. See Table 1, Bar Codes on page 51 for more information. p6 = Wide bar width Wide bar width in dots. Accepted Values: 2-30 See Table 1, Bar Codes on page 51 for more information. p7 = Bar code height Bar code height in dots. p8 = Print human readable code Accepted Values: B = yes N = no DATA = Fixed data field The data in this field must comply with the selected bar code’s specified format. The backslash (\) character designates the following character is a literal and will encode into the data field. Refer to the following examples: To Print Enter into data field " \" “Company” \”Company\” \ \\ \code\ \\code\\ EPL Programming Guide 5/30/07 EPL Commands B Table 1 • Bar Codes P4 Value P5 Value P6 Value Code 39 std. or extended 3 1-10 Y Code 39 with check digit 3C 1-10 N Code 93 9 1-10 N Code 128 UCC Serial Shipping Container Code 0 1-10 N Code 128 auto A, B, C modes 1 1-10 N Code 128 mode A 1A 1-10 N Code 128 mode B 1B 1-10 N Code 128 mode C 1C 1-10 N Code 128 with Deutsche Post check digit 1D 2-10 N Codabar K 1-10 Y EAN8 E80 2-4 N EAN8 2 digit add-on E82 2-4 N EAN8 5 digit add-on E85 2-4 N EAN13 E30 2-4 N EAN13 2 digit add-on E32 2-4 N EAN13 5 digit add-on E35 2-4 N German Post Code 2G 3-4 N Interleaved 2 of 5 2 1-10 Y Interleaved 2 of 5 with mod 10 check digit 2C 1-10 Y Interleaved 2 of 5 with human readable check digit 2D 1-10 Y Postnet 5, 9, 11 & 13 digit P — N Planet 11 & 13 digit PL — N J — — 1E 1-10 N UPC A UA0 2-4 N UPC A 2 digit add-on UA2 2-4 N UPC A 5 digit add-on UA5 2-4 N UPC E UE0 2-4 N UPC E 2 digit add-on UE2 2-4 N UPC E 5 digit add-on UE5 2-4 N UPC Interleaved 2 of 5 2U 1-10 Y Plessey (MSI-1) with mod. 10 check digit L — — MSI-3 with mod. 10 check digit M — — Description Japanese Postnet UCC/EAN 128 5/30/07 EPL Programming Guide 14245L-001 Rev. A 51 52 EPL Commands B Bar Code Table Notes 1. Hyphens maybe used in data as a data separator and will be ignored. 2. Use ASCII 06 to delimit variable length fields. 3. Japanese Postal Code accepts alpha-numeric characters. It truncates the data after 20 characters, and pads up to 20 with a pad character. 4. The data for a Deutsche Post Code 128 barcode consists of 12 characters: BBNNNNNNNNDE, where B is any character in the ‘B’ character set, N is any decimal digit (‘0’ – ‘9’), and DE are the literal characters “DE” (Germany). A 1D bar code type creates a standard Code 128 symbol, but the firmware calculates and inserts a check digit between the last N and the DE before rendering the bar code. It will abort and report a syntax error if any of the 8 characters between AA and DE are not digits. It will, however, allow any number of function codes F1 through F3 to be interspersed with the digits. 5. Planet: See USPS Publication 197 for details. Either 11 or 13 digits may be supplied, and the printer calculates and appends a check digit for a total of 12 or 14 digits. As with Postnet, hyphens (‘-’) may be used as data separators for readability and will be discarded by the printer. Example 1 • B10,10,0,PL,5,5,5,N,"12-34567-890123" Example 2 • N↵ B10,10,0,3,3,7,200,B,"998152-001"↵ P1↵ produces this label: 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands B Bar Codes with Variables & Counters The data field can be replaced by or combined with the following commands: • Vnn = Prints the contents of variable “nn” at this position. Range of nn = 00 to 99. • Cn = Prints the contents of counter “n” at this position. Range of n = 0 to 9 See Appendix C for additional Data parameters for printers with the RTC (real time clock) option installed. Example • B50,0,0,3,1,2,50,B,"DATA"↵ : Writes bar code B50,50,0,3,1,2,50,N,V01↵ : Writes contents of variable 01 as bar code B50,50,0,3,1,2,50,N,C1↵ : Writes contents of counter 1 as bar code B50,50,0,3,1,2,50,N,C1+2↵ : Writes contents of counter 1 plus2 as bar code or a combination of several options: B50,300,0,3,1,2,50,B,"Deluxe"V01C2"Combo"V01↵ : Writes the text “Deluxe” followed by the contents of variable 01 followed by the contents of counter 2 followed by the text “Combo” followed by the contents of variable 01 all as a code 39 bar code. or a combination of several options: B50,300,0,3,1,2,50,B,"Deluxe"V01C2"Combo"V01↵ : Writes the text “Deluxe” followed by the contents of variable 01 followed by the contents of counter 2 followed by the text “Combo” followed by the contents of variable 01 all as a code 39 bar code. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 53 54 EPL Commands B Data with the RTC Time & Date Functions The “Data” field can be replaced by or combined with the following variables: • TT = Prints the current time at this position in the predefined format. See the TT command for format selection. This variable is available only if the printer Time & Date option is installed. • TD = Prints the current date at this position in the predefined format. See the TD command for format selection. This variable is available only if the printer Time & Date option is installed. Note • Some bar code formats will not support date names or the date or time delimiters used by the printer to separate data parameters. Code 128 Bar Code Function Characters The printer supports Code 128 function control characters (FCN#). Multiple FCN#s, TTs, TDs and “DATA” strings can be concatenated, allowing them to be inserted anywhere within the symbol. FCN2, FCN3 and FCN4 are illegal in Code 128 mode C (p4 = 1C) and will result in a syntax error. Please refer to the Code 128 standard for a description of function characters FNC1 through FNC3. “Standard” Code 128 can encode all 128 standard ASCII characters (0 – 127). Function character FCN4 provides a means of also encoding extended ASCII characters (128 – 255). It directs the reader to add 128 to the value of each affected character before transmitting it. Two consecutive FCN4s toggle between standard and extended ASCII mode for all succeeding data characters (until the end of the symbol, or until another pair of FCN4s is encountered). This is referred to as latching into extended ASCII mode or latching into standard ASCII mode. A single FCN4 toggles between standard and extended ASCII mode for only a single following data character. This is referred to as shifting into extended ASCII mode or shifting into standard ASCII mode. Both code sets A and B are needed to represent the entire extended ASCII character set, just as both sets are needed to represent the standard ASCII character set. FCN4s can be inserted manually, if necessary or desired, by following the syntax described above. The printer will, however, insert them automatically if extended ASCII characters are encountered in the DATA. It will do so in the most efficient manner possible: • If up to 4 contiguous extended ASCII characters are encountered, it will shift into extended ASCII mode by inserting a single FCN4 before each one; • If 5 or more contiguous extended ASCII characters are encountered, it will latch into extended ASCII mode by inserting two FCN4s before them. • While latched into extended ASCII mode, it will apply the same rules if standard ASCII characters are encountered. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands B Thus, the preferred way to encode extended ASCII characters is to simply embed them in the DATA and let the printer manage the encoding task. For best results, the code set should also not be specified (i.e., p4=1). FCN4 s should be manually inserted only in systems where extended ASCII characters cannot be transmitted to the printer. Important • It is illegal to mix automatic and manual modes within the data for a single symbol; i.e., an extended ASCII character encountered in the data after an will be considered a syntax error. Likewise, an FCN4 after an extended ASCII character will also be considered a syntax error. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 55 56 EPL Commands B B RSS-14 Bar Code Specific Options Description Use this command to print RSS-14 bar code family bar codes for numeric data. The printer supports a subset of the RSS bar code family set. The subset includes basic RSS14, RSS Limited, RSS Stacked and RSS Truncated. The printer does not support RSS Expanded or two dimensional composite bar codes. Printer Models: 3842 and 2844* * - Available as a firmware download from the www.zebra.com website. Syntax Bp1,p2,p3,p4,p5,p6,p7,p8,”DATA” Parameters This table identifies the parameters for this format: Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. p3 = Rotation Accepted Values: 0 = normal (no rotation) 1 = 90 degrees 2 = 180 degrees 3 = 270 degrees p4 = RSS-14 Bar Code selection 14245L-001 Rev. A Value Description Width Multiplier Min. Height Multiplier R14 Basic RSS-14 96 33 RL Limited 74 10 RS Stacked 50 13 RT Truncated 96 13 p5 = Narrow bar width Narrow bar width in dots. Accepted Values: 1-10 The narrowest module will be this number of dots. Symbol Width is the value of p5 times the applicable bar code Width Multiplier listed in the table for the selected RSS-14 bar code type (p4). This overall symbol width value includes the required symbol "quite zone". p6 = Wide bar width Wide bar width in dots. Accepted Values: 2 p7 = Bar code height Bar code height in dots. EPL Programming Guide 5/30/07 EPL Commands B 5/30/07 Parameters Details p8 = Print human readable code. Accepted Values: B = yes N = no DATA = Fixed data field. The data in this field must comply with the selected bar code’s specified format. The backslash (\) character designates the following character is a literal and will encode into the data field. Refer to the following examples: Value Description Max. Numeric Value R14 Basic RSS-14 9999999999999 RL Limited 1999999999999 RS Stacked 9999999999999 RT Truncated 9999999999999 EPL Programming Guide 14245L-001 Rev. A 57 58 EPL Commands B Data with the RTC Time & Date Functions The “Data” field can be replaced by or combined with the following variables: • TT = Prints the current time at this position in the predefined format. See the TT command for format selection. This variable is available only if the printer RTC Time & Date option is installed. • TD = Prints the current date at this position in the predefined format. See the TD command for format selection. This variable is available only if the printer RTC Time & Date option is installed. Because the RSS-14 bar code symbols only support numeric data, the time and date data recalled by the TD and TT commands must not include delimiters, i.e. "/,-, or :" or any other delimiters Example 1 • N↵ B100,100,0,RL,4,4,40,B,"1234567890"↵ B100,300,0,R14,4,4,40,B,"1234567890"↵ B100,500,0,RS,4,4,52,B,"1234567890"↵ B100,700,0,RL,4,4,40,B,"9876543210"↵ P↵ will produce this label: 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands B Example 2 • N↵ B100,100,0,RL,4,4,40,B,"1234567890"↵ B400,300,0,RT,4,4,40,B,"1234567890"↵ B500,900,0,RS,4,4,54,B,"1234567890"↵ B500,900,1,RS,4,4,54,B,"1234567890"↵ B500,900,2,RS,4,4,54,B,"1234567890"↵ B500,900,3,RS,4,4,54,B,"1234567890"↵ B100,1350,0,RL,4,4,40,B,"9876543210"↵ P↵ will produce this label: 5/30/07 EPL Programming Guide 14245L-001 Rev. A 59 60 EPL Commands b b 2D Bar Code – Aztec Specific Options Description Use this command to print an Aztec two dimensional bar code symbol. The symbols are square on a square grid with a square central bullseye finder. Data is encoded in a series of “layers” that circle around the bullseye pattern. Each additional layer completely surrounds the previous layer thus causing the symbol to grow in size as more data is encoded. Supported Printer Models: 2844 Available as a firmware download from the www.zebra.com website. Syntax bp1,p2,p3,[p4,][p5,][p6,][p7,][p8,]”DATA” Parameters This table identifies the parameters for this format: Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. p3 = A - Selects Aztec bar code — Order is not important for parameters p4-p8. Include the prefix letter (d,e,f,m or r) to select the parameter followed by a valid numeric value. 14245L-001 Rev. A p4(d)= Symbol Scaling Default Value: 3 Accepted Values: 1–55 p5(e) = Symbol layer and/or error correction levels. Both layer and error correction effect the symbol size. Accepted Values: e0 = Default checkword level (23% +3) e1–e99 = 1% to 99% check words e101–e104 = Compact symbol with 1 to 4 layers e201–e232 = Full symbol with 1 to 32 layers e300 = Rune symbol p6(f) = Enables the flg(n) format Enables the flg(n) format using the ASCII Escape character (27 decimal). Default Value: Disabled p7(m) = Enables menu support option Default Value: Disabled p8(r) = Selects an inverse image of the bar code Selects an inverse image of the bar code (sometimes known as reverse video or a negative image). "DATA"=ASCII data or Binary data bytes Any combination of data strings, time fields (TT), date fields (TD), variables and/or counters (the latter two within forms only) that resolve to a valid string of characters. EPL Programming Guide 5/30/07 EPL Commands b Within literal strings all ASCII characters 0–255 dec. (00-FF hex.) are allowed. Quotes (ASCII 34d) and backslashes (ASCII 92d) must be uniquely handled. The backslash (\) character designates the following character is a literal and will encode into the data field. Refer to the following examples: To Print Enter into data field " “Company” \ \code\ ø \" \“Company\” \\ \\code\\ \↵ Within forms, further limitations include that a NULL (ASCII 0) character may not appear within bar code DATA and entry limitations do not provide for a way to enter linefeed characters into variables. The programmer should rely on the symbology’s specification to insure format compliance and proper implementation. See the AIM web site for specifications at: http://www.aimglobal.org/ Example 1 • This Aztec Bar Code example uses default values for all parameters. b0,0,A,"0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ" Example 2 • This Aztec Bar Code example specifies an element size of 9 (triple the default). b0,0,A,d9,"0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ" 5/30/07 EPL Programming Guide 14245L-001 Rev. A 61 62 EPL Commands b Example 3 • This Aztec Bar Code example specifies a checkword level of 98%. b0,0,A,e98,"0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ" Example 4 • This Aztec Bar Code example specifies a compact symbol with 4 layers. b0,0,A,e104,"0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ" Example 5 • This Aztec Bar Code example specifies a full symbol with 9 layers. b0,0,A,e209,"0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ" Example 6 • This Aztec Bar Code example specifies a Rune symbol. b0,0,A,e300,"0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ" 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands b Example 7 • This Aztec Bar Code example specifies flg(n) format using ASCII 27 escape character. b0,0,A,f,"0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ" Example 8 • This Aztec Bar Code example specifies a menuing symbol. b0,0,A,m,"0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ" u g sy bo . Example 9 • This Aztec Bar Code example specifies reverse printing (white on black). b0,0,A,r,"0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ" se printing (wh 5/30/07 EPL Programming Guide 14245L-001 Rev. A 63 64 EPL Commands b b 2D Bar Code – Aztec Mesa Specific Options Description Use this command to print an Aztec Mesa composite bar code symbol (a standard linear bar code and a modified Aztec two dimensional bar as a single symbol. The two dimensional data is encoded in a series of “layers” lying above and in some cases continuing below the adjacent standard bar code symbol. Printer Models: 2844 Available as a firmware download from the www.zebra.com website. Syntax bp1,p2,p3,p4,[p5,][p6,][p7,][p8,][p9,][p10,][p11,]”DATA Parameters This table identifies the parameters for this format: Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. p3 = AZ - Selects Aztec bar code — Order is not important for parameters p4-p8. Include the prefix letter (d,e,f,m or r) to select the parameter followed by a valid numeric value. p4(d)= Standard linear bar code Use the B command parameters to populate this parameter. The B command's horizontal and vertical start symbol position parameters p1 and p2 are not used. This p4 parameter is terminated with the a Z immediately following the standard bar codes DATA parameter 'close quote' ("). Example • This is an example of a standard bar code: B50,0,0,3,1,2,50,B,"1234567890abc"↵ Example • This is an example of p4 portion of the standard bar code of the same bar code symbol. 0,3,1,2,50,B,"1234567890abc"Z 14245L-001 Rev. A p5(e) = Symbol layer and/or error correction levels. Both layer and error correction effect the symbol size. Accepted Values: e0 = Default checkword level (23% +3) e1–e99 = 1% to 99% check words e101–e104 = Compact symbol with 1 to 4 layers e201–e232 = Full symbol with 1 to 32 layers p6(f) = Enables the flg(n) format Enables the flg(n) format using the ASCII Escape character (27 decimal). Default Value: Disabled EPL Programming Guide 5/30/07 EPL Commands b Parameters Details p7(m) = Enables menu support option Default Value: Disabled p8(r) = Selects an inverse image of the bar code Selects an inverse image of the bar code (sometimes known as reverse video or a negative image). p9(b) = Intra Symbol Barrier Width Specifies the width of the barrier in narrow bar widths between the Aztec and standard linear bar code areas. Accepted Values: 1–9 Default Value: 4 for EAN 13 and UPC A, 2 for all other supported standard linear bar codes p10(s) = Symbol Symmetry Must preceed the p11(c)parameter. Default Value: Regular (stacked) Value: e (even symmetry) p11(c) = Selects an inverse image of the bar code Enables the flg(n) format using the ASCII Escape character (27 decimal). Default Value: Disabled "DATA"=ASCII data or Binary data bytes Any combination of data strings, time fields (TT), date fields (TD), variables and/or counters (the latter two within forms only) that resolve to a valid string of characters. Within literal strings all ASCII characters 0–255 dec. (00-FF hex.) are allowed. Quotes (ASCII 34d) and backslashes (ASCII 92d) must be uniquely handled. The backslash (\) character designates the following character is a literal and will encode into the data field. Refer to the following examples: To Print Enter into data field " “Company” \ \code\ ø \" \“Company\” \\ \\code\\ \↵ Within forms, further limitations include that a NULL (ASCII 0) character may not appear within bar code DATA and entry limitations do not provide for a way to enter linefeed characters into variables. The programmer should rely on the symbology’s specification to insure format compliance and proper implementation. See the AIM web site for specifications at: http://www.aimglobal.org/ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 65 66 EPL Commands b b 2D Bar Code – Data Matrix Specific Options Description Use this command to print Data Matrix two dimensional bar code symbols. The printer will automatically interpret and encode data into Data Matrix bar code symbols, using the ECC 200 data quality format. Individual module size, columns and rows parameters can be specified or the printer can automatically calculate and set one or all of these parameters. The symbol is made of square modules arranged within a rectangular shape which includes a perimeter scan recognition pattern. The scan recognition pattern produced by the EPL2 printer also includes a "quiet zone" one module wide on all outside edges of the bar code to ensure data integrity. Printer Models: 3842 and 2844* * Available as a firmware download from the www.zebra.com website. Syntax bp1,p2,p3,[,p4,][,p5][,p6][,p7],”DATA” Parameters This table identifies the parameters for this format: Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. p3 = D - Selects Data Matrix bar code — Order is not important for parameters p4-p7. Include the prefix letter (c,r,h, or v) to select the parameter followed by a valid numeric value. p4(c)= Number of columns to encode See the Symbol Geometries table for valid column values. p5(r) = Number of rows to encode See the Symbol Geometries table for valid row values. p6(h) = Enables the flg(n) format Sets the minimum square data module size used for encoding data. Accepted Values: 1-40 Default Value: 5 p7(v) = Selects an inverse image of the bar code Selects an inverse image of the bar code (sometimes known as reverse video or a negative image). "DATA"=ASCII data or Binary data bytes Any combination of data strings, time fields (TT), date fields (TD), variables and/or counters (the latter two within forms only) that resolve to a valid string of characters. Within literal strings all ASCII characters 0–255 dec. (00-FF hex.) are allowed. Quotes (ASCII 34d) and backslashes (ASCII 92d) must be uniquely handled. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands b The backslash (\) character designates the following character is a literal and will encode into the data field. Refer to the following examples: To Print Enter into data field " “Company” \ \code\ ø \" \“Company\” \\ \\code\\ \↵ Within forms, further limitations include that a NULL (ASCII 0) character may not appear within bar code DATA and entry limitations do not provide for a way to enter linefeed characters into variables. The programmer should rely on the symbology’s specification to insure format compliance and proper implementation. See the AIM web site for specifications at: http://www.aimglobal.org/ Table 2 • Data Matrix Symbol Geometries Rows Columns Numeric Capacity.. Alpha-numeric Capacity_ Compressed data size_ 8 18 10 6 5 8 32 20 13 10 10 10 6 3 3 12 12 10 6 5 12 26 32 22 16 12 36 44 31 22 14 14 16 10 8 16 16 24 16 12 16 36 64 46 32 16 48 98 72 49 18 18 36 25 18 20 20 44 31 22 22 22 60 43 30 24 24 72 52 36 26 26 88 64 44 1. Paired digits represent the best-case compression. Adjacent digit pairs can be encoded into eight bits. 2. The implied cmopressibility requires the data be composed of either all lowercase or all uppercase characters with digits and spaces allowed. 3. Any ASCII character (0–127) can be encoded one-to-one, extended ASCII (128-255) requires an additional two-byte overhead. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 67 68 EPL Commands b Table 2 • Data Matrix Symbol Geometries Rows Columns Numeric Capacity.. Alpha-numeric Capacity_ Compressed data size_ 32 32 124 91 62 36 36 172 127 86 40 40 228 169 114 44 44 288 214 144 48 48 348 259 174 52 52 408 304 204 64 64 560 418 280 72 72 736 550 368 80 80 912 682 456 88 88 1152 862 576 96 96 1392 1042 696 104 104 1632 1222 816 120 120 2100 1573 1050 132 132 2608 1954 1304 144 144 3116 2335 1558 1. Paired digits represent the best-case compression. Adjacent digit pairs can be encoded into eight bits. 2. The implied cmopressibility requires the data be composed of either all lowercase or all uppercase characters with digits and spaces allowed. 3. Any ASCII character (0–127) can be encoded one-to-one, extended ASCII (128-255) requires an additional two-byte overhead. Automatic Data Matrix Bar Code Generation The printer automatically tests and changes the Data Matrix bar code geometry to optimize the symbol size per the specified column and row (p4 - thec prefix and p5 - the r prefix) parameters. If no row or column parameters are specified, the printer will create a minimum size symbol based on the calculated compressed size of the data. The number of columns and rows in the symbol will be automatically determined with a preference towards the smallest square symbol that will accommodate the compressed size. The user may wish to force the number of rows and/or columns to a larger value to achieve uniform symbol sizes. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands b If the column (c)parameter is only specified and it's “18”, “26”, “32”, “36”, or “48”, or if only rows is specified and it is “8”, “12”, or “16”, a rectangular symbol may be produced. For example, if “,r12” is specified (with no column parameter), then sizes 12x12, 12x26, and 12x36 are possible selections. The alphanumeric capacity of those symbols is 6, 22, or 31 characters respectively. The smallest symbol size that will accommodate the data will be created. If rows, cols, and/or data length are not compatible with a symbol from the Symbol Geometries table, an error 03 (Data Length Error) will be reported, and no symbol will be produced. Example • N↵ b30,20,D,h8,"Zebra Technologies corporation is the leading worldwide manufacturer of bar code labeling solutions and a leading provider of instant-issuance plastic card printers. We distribute our on-demand bar code label printers, plastic card printers, secure ID printing systems, software and related supplies under the Zebra and Eltron brand names to users in more than 90 countries. Our products are used in high-growth automatic identification applications that improve quality and productivity. We count among our customers more than 70 percent of the FORTUNE 500."↵ will produce 5/30/07 EPL Programming Guide 14245L-001 Rev. A 69 70 EPL Commands b b 2D Bar Code – MaxiCode Specific Options Description Use this command to generate MaxiCode bar code symbols with a single command. The printer will automatically interpret and encode data into MaxiCode symbols for data modes 2, 3, 4, and 6. Up to eight symbols can be linked. Syntax bp1,p2,p3,[p4,][p5,]“DATA” Parameters This table identifies the parameters for this format: Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. p3 = M - Selects MaxiCode bar code — p4(c)= Mode selection Value Description Not Used Automatic selection Mode 2 or 3 m2 Mode 2 m3 Mode 3 m4 Mode 4 m6 Mode 6 1. If p4 (mx) is not used, the printer will use the following rules to automatically format the “DATA” parameter. If the postal code (third parameter, PC) in the “DATA” is: • All numeric characters, the printer will automatically select Mode 2. • Alpha only or alpha-numeric character combinations will set the printer to Mode 3. • Not used, the printer automatically selects Mode 3. 2. If p4 value is “m2orm3”, the printerwill use the following rules to format the “Data” parameter: In Mode 2 - If a non-numeric character is entered in the Postal Code “Data” parameter field, then the MaxiCode bar code will not print. • In Mode 3 – If the Postal Code “Data” field exceed 6 characters, then the additional characters will be truncated from the bar code field. • 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands b Parameters Details p5 = x,y Associated MaxiCode symbol numbering where: x = Symbol Number of y = Total Number of Associated Symbols Accepted Values: 1-8 for both x or y Default Value: Not used "DATA"=Mode dependent data format Mode dependent data is bounded by quotation marks. Maximum of 2 KBytes of data. Mode Data Format 2&3 “cl,co,pc,lpm” 4&6 “lpm” cl = Class Code (3 digits required) co = Country Code (3 digits required) Mode 2 = Numeric Characters Mode 3 = International Characters (up to 6 characters) pc = Postal Code Mode 2 = 5 or 9 characters (All Numeric, including USA Postal ZIP 5 or 9 char.) For less than 9 characters, the printer will pad the field with 0’s. Mode 3 (International)= Any alphanumeric character (up to 6 characters) lpm = Low priority message (data) ASCII printable characters (up to 84 characters per symbol), any 256 character map. The programmer should rely on the symbology’s specification to insure format compliance and proper implementation. See the AIM web site for specifications at: http://www.aimglobal.org/ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 71 72 EPL Commands b Example • N↵ b20,20,M,"300,840,93065,1692,This is MaxiCode, but not MaxiCode formatted data"↵ P1↵ will produce Using AIM Specified MaxiCode Data Formatting The EPL printer can use and automatically decode the AIM ITS (International Technical Standards) MaxiCode data format. The printer detects the message/start header ([)>RS), field separator (GS), and the end of message marker (RS EOT) data control strings. The hexadecimal (ASCII) data control strings are in the following table. See the EPL2 dump mode character map in Appendix A. Control String Hexadecimal Code Message/Start Header [ ) > RS 5B 29 3E 1E Field Separator GS 1D End Of Message Marker RS EOT 1E 04 Syntax bp1,p2,M,p4 “[AIM MaxiCode Data]” 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands b Example • b20,400,M,m2”001,840,93065,1692,[)>RS 01GS98XXXZZFDAAFGSSHIPGS309GSGS1/1GS10GS NGSGSCAMARILLOGSCAGSRSEOT!!!!!!!!!!!!!!!!!!!!!!!”↵ Note • 1. This programming example represents actual data used to format a single AIM- compliant MaxiCode symbol as programmed by a major international and domestic shipping company. 2. The shipper has explicitly set the MaxiCode symbol for Mode 2. This can be omitted by the programmer and the printer will auto-select the mode per the rules on page 70. 3. The shipper has used the “!” character to pad the symbol’s data. A scanner reads back all the “Data” within the quotation marks, including the “!” characters following the End of Message Marker (EOT). 4. All of the data fields in the Low Priority Message are not used in the example. Some are left empty with the field delimiting GS character used as a format field holder. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 73 74 EPL Commands b b 2D Bar Code – PDF417 Specific Options Description Use this command to print PDF 417 and Macro PDF bar code symbols. The printer will automatically change from PDF417 to Macro PDF bar code mode if the data sent to the printer exceeds the maximum amount supported by the PDF417 symbol. The oH command is used to place the addition Macro PDF symbols needed for the continuation data. The printer will automatically optimize the symbol for readability of data (and use the minimum number of symbols when using Macro PDF). The symbol’s geometry is adjusted (typically reducing the size of the symbol) per the defined parameters. The printer will use the largest module size (bar width and height) and minimize the number of rows and columns. Syntax bp1,p2,p3,p4,p5[,p6][,p7][,p8][,p9][,p10][,p11][,p12][,p13] [,p14][,p15],”DATA” Parameters This table identifies the parameters for this format: Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. p3 = P Must be “P” for PDF 417 bar codes. p4(www) = Maximum print width Maximum print width in dots. p5(hhh) = Maximum print height Maximum print height in dots The programmer should rely on the symbology’s specification to insure format compliance and proper implementation. See the AIM web site for specifications at: http://www.aimglobal.org/ Note • The following parameters may be omitted and default values will automatically be inserted. Each parameter value (data string) must be proceeded by its associated command prefix character. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands b 5/30/07 Parameters Details p6(s) = Sets error correction level Error Correction codewords per symbol. If level is not specified, a level will automatically be assigned as per the following table: Accepted Values: s1 - s8 EC Level EC Codewords Auto Select Level 0 2 — 1 4 0–31 2 8 32–63 3 16 64–127 4 32 128–255 5 64 256–511 6 128 512–928 7 256 — 8 512 — EPL Programming Guide 14245L-001 Rev. A 75 76 EPL Commands b Parameters Details p7 = selects data compaction (compression) method Accepted Values: 0 or 1 Default Value: 0 c0 = Auto-encoding The printer will switch between the three compaction modes as needed to create the smallest possible symbol for the given data. c1 = Binary mode The printer will encode the symbol in byte compaction mode. PDF417 uses an intermediate data type called a “codeword” to store the characters in the symbol. Each codeword typically consumes a fixed-size portion of the total symbol. More characters inserted into a codeword results in fewer codewords needed to create a symbol. This results in a smaller symbol. To provide efficient data compaction, PDF417 supports three types of codewords: text, numeric and binary. Auto-Encoding (c0) data compaction method is set by default, and provides the best compaction. If Binary data compaction (c1) is selected the symbol will typically be larger. Binary data compaction may help to minimize the amount of time it takes a system to scan and decode the data encoded within the symbol. • • • p8 (pxxx,yyy,mm)= print human readable 14245L-001 Rev. A Data Type Compaction (Byte by Byte) Text 2 Characters per codeword Numeric 2.93 Characters per codeword Binary 1.2 Bytes per codeword Text compaction can be used for uppercase, lowercase, numbers, space, carriage return, tab, line feed, and the following characters: &,:#-.$/+%*=^;@[\]_’~!"|(){}` With text compaction, up to two characters can be encoded in a single codeword. Numeric compaction can be used for numbers only. Up to 2.93 characters can be encoded in a single codeword. Byte compaction can be used for any character. But the flexibility comes at a price; byte compaction encodes only 1.2 characters per codeword. This parameter is a non-standard implementor of the PDF417 and is only recommended for troubleshooting purposes. Additional variables: p = "p" - parameter identifier xxx = horizontal start location yyy = vertical start location mm = maximum characters per line EPL Programming Guide 5/30/07 EPL Commands b 5/30/07 Parameters Details p9(f)= Bar code origin point Accepted Values: 0 or 1 Default Value: 1 f1 - Center of bar code as defined by the automatically adjusted symbol size, i.e. width and height. Parameters p4 and p5 values are maximum values only. f0 - Upper left corner of bar code. p10(x)= module width (in dots) Accepted Values: 2 - 9 (i.e. x2-x9) Default Value: Auto selects 6 (dots). Tests data with maximum size limit set by p4 and p5 and then the other optional parameters. The printer automatically reduces the module width in one dot increments until the data fits within the symbols maximum dimensions (and other applied parameters) or until 3 dots has failed, then reports an error. p11(y) = set bar height (in dots) Accepted Values: 4 – 99 (i.e. y4-y99) Default Value: 4 times module width (p10) p12(r) = maximum row count Maximum limit for the number of rows to be used for auto selecting symbol features. p13(l) = maximum column count Maximum limit for the number of columns to be used for auto selecting symbol features. p14(t) = truncated flag Accepted Values: 0 = not truncated 1 = truncated See the PDF 417 specification for details. EPL Programming Guide 14245L-001 Rev. A 77 78 EPL Commands b Parameters Details p15(o) = rotation Accepted Values: 0 = 0º 1 = 90º 2 = 180º 3 = 270º Settings of 90° & 270° will cause the symbols maximum height (p4) andwidth (p5) values to transpose when automatically calculating and generating the symbol, i.e. the height would affect column dimensions and width would affect row dimensions. “DATA” = ASCII data or binary data bytes Represents a fixed data field. The backslash (\) character designates the following character is a literal and will encode into the data field. To Print Enter into data field " \" “Company” \”Company\” \ \\ \code\ \\code\\ ø \↵ PDF 417: General Information A PDF417 symbol is organized into minimum of 3 to a maximum of 90 rows and a minimum of 5 to a maximum of 34 columns of codewords. Each codeword is 17 modules wide. There are 4 bars and 4 spaces per codeword. Multiply the module width (in dots, p10) by 17 to get the codeword width. Multiply the module height (in dots, p11) by the number of rows to get the symbol height. Four of the codewords in each row are start, stop and two row indicators. The remaining codewords are referred to as the data region and contain symbol overhead and compacted data. There can be no more than 928 codewords in the data region. All combinations of rows and columns are not legal; 90 rows times 30 columns would produce a data region of 2700 codewords which exceeds the 928 codeword maximum per symbol. See the following table (on the next page) that shows the maximum number of rows and the resulting number of codewords in the data region for each column count. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands b PDF 417 Symbol Geometry Columns Maximum Rows Codewords Columns Maximum Rows Codewords 5 90 90 18 66 924 6 90 180 19 61 915 7 90 270 20 58 928 8 90 360 21 54 918 9 90 450 22 51 918 10 90 540 23 48 912 11 90 630 24 46 920 12 90 720 25 44 924 13 90 810 26 42 924 14 90 900 27 40 920 15 84 924 28 38 912 16 77 924 29 37 925 17 71 923 30 35 910 18 66 924 31 34 918 19 61 915 32 33 924 20 58 928 33 32 928 21 54 918 34 30 900 Automatic PDF 417 Bar Code Generation The printer automatically tests and changes the PDF 417 bar code geometry to maximize the readability of the bar code for a given maximum height and width, specified by p4 and p5. The printer tests the PDF 417 parameters in this order for a given data string (error correction and compression included): 1. Module width p10 (for codeword width) 2. Symbol width p4 3. Symbol column maximum p13 4. Module height p11 5. Symbol height p5 6. Symbol row maximum p12 The printer will start with the maximum value (default or explicit) for these parameters. The printer reduces these values to get the module width and height to maximize readability. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 79 80 EPL Commands b Example • N↵ b80,100,P,700,600,x2,y7,l100,r100,f0,s5," \ ↵ Fourscore and seven years ago our fathers brought forth on this continent a new nation, conceived in liberty and dedicated to the proposition that all men are created equal. Now we are engaged in a great civil war, testing whether that nation or any nation so conceived and so dedicated can long endure.↵ “↵ ø b80,200,P,400,300,p40,440,20,f1,x3,y10,r60,l5,"ABCDEFGHI JK1234567890abcdefghijk"↵ P↵ will produce this label: The second symbol has been set to print human readable data with the p8 parameter (p40,440,20) and is not part of the PDF417 symbol. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands b b 2D Bar Code – QR Code Specific Options Description Japanese printer models only. Use this command to generate QR Code bar code symbols with a single command. See the AIM web site for QR Code specifications at http://www.aimglobal.org/ Syntax bp1,p2,p3,[p4-9]”DATA” Parameters This table identifies the parameters for this format: Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. p3 = Q Must be “Q” for QR Code. Parameters p4 through p8 are optional and may be omitted. Default values will automatically be inserted when a parameter is omitted. Each parameter value must be proceeded by its associated command prefix character. The parameters p4 through p8 can be inserted into the command string in any order prior to the “DATA” and following p3. Commas between parameters p4 through p8 are not required. 5/30/07 p4 = Code Model (prefix m) Accepted Values: 1 = Model 1 2 = Model 2 Default Value: Model 2 p5 = Scale Factor (prefix s) Accepted Values: 1–99 Default Value: 3 p6 = Error Correction Level (prefix e) Accepted Values: L = Lower error correction, most data M = Default Q = Optimized for error correction over data H = Highest error correction, least data Default Value: M p7 = Data Input Mode (prefix i) Accepted Values: A = Automatic Data Select M = Initialized the manual data mode and the data type is set by the first character in the fixed data field (“DATA”). Default Value: A EPL Programming Guide 14245L-001 Rev. A 81 82 EPL Commands b Parameters Details p8 = Append Symbol (prefix D) The Append Symbol parameter option allows the programmer to join data from 2 to 16 QR code symbols. “DATA” = Represents a fixed data field Sub-prefix Values Description c 01-16 Symbol Number d 01-16 Divisions p 00-FF Hex. Parity Data sent to the printer is converted to one of four formats depending upon the value set by parameter p7, Data Input Mode select. By default, the printer will automatically select the data mode for the entire fixed data string. The printer will check and change the data encoding method to achieve the highest data compression. If parameter p7 is set to IM, then first character in the Data must be one of the following: N - Numeric (0-9) A - Alphanumeric (0-9, A-Z, a-z and space,$,%, *,+, -, . , /, : ) K - Kanji (Shift JIS character ranges 8140-9FFC and E040EAA4 Hex) B - Binary The data field has reserved characters that normally can not be used within the data string, they are: “ and / . The backslash (\) character designates the following character is a literal and will encode into the data field. Refer to the following examples: To Print Enter into data field " \" “Company” \”Company\” \ \\ \code\ \\code\\ ø 14245L-001 Rev. A EPL Programming Guide \↵ 5/30/07 EPL Commands C C Counter Description The counter (C) command defines one of 10 automatic counters used in consecutive numbering applications (i.e. serial numbers). Counters must be defined after variables. For Numeric Serialization Only. The counter function does not support Alpha or AlphaNumeric Serialization. The C command is used in forms that require sequential numbering. When initializing counters, they must be defined in order (e.g. C0 first, C1 second...). Field justification (p3) affects the printing of counter data. When L, R or C are selected, the counter field is the width of p2 value. Data will justify within the counter (p2) field per the selected p3. The N parameter will print the minimum number of characters. To print the contents of the counter, the counter number is referenced in the “DATA” field of the A (ASCII text) or B (Bar Code) commands. Syntax Cp1,p2,p3,p4 ”[-]PROMPT” Parameters This table identifies the parameters for this format: Parameters Details p1 = Counter number Accepted Values: 0–9 p2 = Maximum number of digits for counter Accepted Values: 1–29 p3 = Field Justification Accepted Values: L = Left R = Right C = Center N = No Justification p4 = Step Value Accepted Values: + or - sign followed by a single digit of 1–9. Using a step value of +0 allows the counter to be used as an additional variable data field. ”PROMPT” An ASCII text field that will be transmitted to the KDU or host (via the serial interface) each time the command is executed. Typically used to request the operator to enter a starting counter value. [-]=KDU Prompt Options Having the first character of the prompt a single minus sign will cause the prompt to display only once after form retrieval. The C command is used in forms that require sequential numbering. When initializing counters, they must be defined in order (e.g. C0 first, C1 second...). 5/30/07 EPL Programming Guide 14245L-001 Rev. A 83 84 EPL Commands C Field justification (p3) affects the printing of counter data. When L, R or C are selected, the counter field is the width of p2 value. Data will justify within the counter (p2) field per the selected p3. The N parameter will print the minimum number of characters. To print the contents of the counter, the counter number is referenced in the “DATA” field of the A (ASCII text) or B (Bar Code) commands. Note • If the starting value of a counter is “1“, then no leading zero padding will be added. If the starting value is “01”, then the counter will be padded, up to the maximum number of digits (p2), with zeros. Example 1 • C0,10,L,+1,"-Enter Serial Number:"↵ Example 2 • Saving and Protecting Consecutive Numbers in Nonvolatile Memory This feature is useful when the counter field represents a serial number (or others types of numbers) that should never be repeated. This feature allows for automatic retrieval and increment (or decrement) of the previous counter value used every time a form is retrieved (and printed). By placing one minus sign as the first character of the prompt, the prompt will appear only once after the form is retrieved, thereby protecting the integrity of the data. Example 3 • Single Digit Summation with Counters Add or subtract a single digit from the recalled counter value in a form. If form recalled counter C0 had a value of 3, then processing C0+1 would yield a value of 4 and C0-2 would yield a value of 1. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands C C Cut Immediate Description This command allows the printer to initiate an immediate media cut without a form print operation. The printer must have the cutter option installed. • The C command – Cut Immediate can not be used inside of a form. • The initial character C in a command string is used for both the Cut Immediate (C) and Counter Command function (Cp1) which can only be used within a form. The Cut Immediate Command (C) can not be used in a form. • The C command – Cut Immediate can not be used with the KDU. Mobile printers, such as the TR 220, ignore this command. Syntax C Parameters There are no parameters for this command. Example • C↵ Note • Use only cut label liner (backing) or tag stock. Label adhesive will build up on the cutter blade and cause the cutter to operate poorly or jam if the labels are cut along with the label liner. Use the C command - Cut Immediate 5 times without media loaded, to perform a self cleaning of the cutter blade. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 85 86 EPL Commands D D Density Description Use this command to select the print density. The density command controls the amount of heat produced by the print head. More heat will produce a darker image. Too much heat can cause the printed image to distort. Syntax Dp1 Parameters This table identifies the parameters for this format: Parameters Details p1 = Density setting Accepted Values: 0–15 Default Value: 2443 (Orion) and 2884: 10 All other printers: 7 Note • 0 is the lightest print and 15 is the darkest. Note • The density and speed commands can dramatically affect print quality. Changes in the speed setting typically require a change to the print density. Example • This example selects density 5. D5↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands dump dump Enable Dump Mode Description This command allows the advanced programmer to force a user diagnostic “data dump” mode. Sending the dump command to the printer allows the programmer to compare actual data sent to printer with the host program. Send data to the printer after the dump command has been issued to evaluate program and printer control data. The printer will process all data bytes into ASCII character data, range 0255 decimal (00-FF hexadecimal). Press the printer’s Feed button until “Out of Dump” is printed or power cycle the printer to terminate the dump mode. Syntax dump Parameters There are no parameters for this format. • Set the image buffer width with the q command to match the media width prior to issuing the dump command. • Use the Dump Mode Character Map on page 319 to interpret the dump mode data (characters printed on the labels) back into ASCII data. • Press the Feed button to view dump data that exceeds a single label¡¯s print area. Repeat to view more dump data as required. • Pressing the Feed button after the dump data is finished printing will cause the printer to exit the dump mode. • Graphics data dump may be large and require multiple labels to print. Example • dump↵ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 87 88 EPL Commands EI EI Print Soft Font Information Description This command will cause the printer to print a list of all soft fonts that are stored in memory. Note • Soft fonts can be downloaded to and deleted from the printer using the Soft Font Downloader Utility or Zebra Designer. Syntax EI Parameters There are no parameters for this format. Example • This example prints a soft font list. EI↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands EK EK Delete Soft Font Description This command is used to delete soft fonts from memory. Note • Soft fonts can be downloaded to and deleted from the printer using the Soft Font Downloader Utility or Zebra Designer. Syntax EK {”FONTNAME”|”*”} Parameters This table identifies the parameters for this format: Parameters Details FONTNAME By entering the name of a font, that font will be deleted from memory. * By including an “*” (wild card), ALL fonts will be deleted from memory. Example 1 • This example deletes font “A” EK”A”↵ Example 2 • This example deletes all fonts. EK”*”↵ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 89 90 EPL Commands eR eR User Defined Error/Status Character Description This command allows the advanced programmer to specify the printer’s error/status report character for error reporting via the RS-232 serial interface. Mobile printers, such as the TR 220, ignore this command. Syntax eRp1,p2 Parameters This table identifies the parameters for this format: Parameters Details p1 = Any single ASCII character Accepted Values: 0–255 decimal (00–FF hexadecimal) p2 = Error/Status Response Mode p2 Mode Descriptions 0 Standard (default): XON (17 dec. / 11 hex.) on Recovery XOFF (19 dec. / 13 hex.) on Error 1 Character Only: Reports the selected error/status character followed by a Carriage Return and Line Feed. 2 Character & Error/Status Code: Reports the selected error/status character, error/status code (see the ^ee command on page 173 for codes), and then by a Carriage Return and Line Feed. Example • For Mode 2 Error and Status Reporting: eR$,2↵ $11↵ $00↵ 14245L-001 Rev. A : Sets Error Character to “$” and : Sets Error Mode to “2". : User operates and prints with printer. : User opens print head. : Reports Print Head Open : User closes print head : Reports No Error : Printer Ready for next command. : (Status report for Print Head Closed) EPL Programming Guide 5/30/07 EPL Commands ES ES Store Soft Font Description This command is used to download and store soft fonts in memory. Note • Soft fonts can be downloaded to and deleted from the printer using the Soft Font Downloader Utility or Zebra Designer. Syntax ES”FONTNAME”p1p2p3a1b1c1”DATA”a2b2c2”DATA2”anbncn”DATAn” Parameters This table identifies the parameters for this format: Parameters Details FONTNAME = One letter font name Accepted Values: a–z, lower case Lower Case named fonts minimize soft font memory usage to only store fonts downloaded and have 256 character limit. The following use hexadecimal coding for parameter values. 5/30/07 p1 = Number of characters to be downloaded Accepted Values: 00–FF hex (0–255 decimal) for 1 to 256 fonts per soft font set. p2 = Character rotation Accepted Values: 00 hex = 0 and 180 degrees 01 hex = 90 and 270 degrees 02 hex = Both 0 and 180 degree rotation pair and the 90 and 270 degree rotation pair p3 = Font height Accepted Values: 00–FF hex Measured in dots and expressed as a hexadecimal number, i.e. 1B hex. = 27 dots. Font height includes accentors and dissenters of characters and need to fit in the character cell. • 203 dpi printers = 256 dots = 1.26 in. = 32.03 mm • 300 dpi printers = 00–FF hex. 256 dots = 0.85 in. = 21.67 mm a1 = (1st) Download character map position Accepted Values: 00–FF hex b1 = (1st) Spacing to next print character Accepted Values: 00–FF hex Downloaded character’s next printed character position in dots, i.e. Character tracking - the space between characters. Must be greater than or equal to the character width, see parameter c1. Dots in a decimal number converted to a hexadecimal number. c1 = (1st) Downloaded characters width Accepted Values: 00–FF hex Dots in a decimal number converted to a hexadecimal number. EPL Programming Guide 14245L-001 Rev. A 91 92 EPL Commands ES Parameters Details “DATA” = (1st) Character bitmap p3 × c1 = bit map data (in bytes) Data is received in bytes, on a line by line basis. The font character’s 0,0 cell map position is in the top left corner of the map as viewed in the 0 degree rotation. See the examples on the following pages. a2 = (2nd) Download character map position Accepted Values: 00–FF hex b2 = (2nd) Spacing to next print character Accepted Values: 00–FF hex c2 = (2nd) Downloaded characters width Accepted Values: 00–FF hex “DATA2” = (2nd) Character bitmap p3 × c2 bytes = bit map data Repeat for each character until the last character in the set is downloaded. an = (Last) Download character map position Accepted Values: 00–FF hex bn = (Last) Spacing to next print character Accepted Values: 00–FF hex cn = (Last) Downloaded characters width Accepted Values: 00–FF hex “DATAn” =Character bitmap p3 × cn bytes = bit map data For fonts with the rotation parameter set for “both” (p2 = 02 hex.): Repeat the individual font character download for each 90° rotated character from the start of the character set until the last rotated character in the set is downloaded. a1-90° b1-90° c1-90° “DATA1-90°” a2-90° b2-90° c2-90° “DATA2-90°” a3-90° b3-90° c3-90° “DATA3-90°” an-90° : (Last) Download Character bn-90° : (Last) Spacing To Next Print Character cn-90° : (Last) Downloaded Character’s Width “DATAn-90°” : Character Bitmap p3 × cn bytes = bit map data The number of individual character maps downloaded will be double the characters in the font set (p1). 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands ES Example 1 • This is an example of measuring a soft font size. 5HIHUHQFH3RLQW 'RWV ' R W V 'RWV 5/30/07 Parameter Dots Data Enteres as Hexadecimal p3 12 0C hex. b 10 0A hex. c 8 08 hex. EPL Programming Guide ,QWHUFKDUDFWHU6SDF DFWXDOO\ZKLWHGRWV 14245L-001 Rev. A 93 94 EPL Commands ES Example 2 • This is an example of soft fonts programming code. The typical soft font downloads command strings to the printer. The following example was generated with the CAL3 software. CR & LF CR & LF p3 a1 b1 c1 a2 b2 c2 a3 b3 p1 p2 c3 CR & LF 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands ES Example 3 • This is an example of font bitmap data format. The black and white bitmap that represents the font must be converted into ASCII hexadecimal code. The 0° font format has dot converted to data bytes reading from left to right and the last byte in a line is padded with zeros to complete the line and data byte. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 95 96 EPL Commands f f Cut Position Description Use this command on an individual printer to provide precision cut placement to: • Compensate for small sensor to cutter position differences on a printer by printer basis. • Fine-tune the cut position to compensate for differences in media. Mobile printers, such as the TR 220, ignore this command. When using the label liner cutter option, the printerwill advance each printed label to the appropriate programmed offset cut position, between labels, before cutting. Due to media differences, the printer may not accurately position the labels before cutting, causing the cutter to cut the label instead of the liner. Note • The printer’s cutter is not designed to cut labels. Labels have adhesive that may interfere with the proper operation of the cutter. Only cut label liner and tag stock and do not exceed the specified media density and thickness of the cutter. If the cut position causes the label just printed to be cut, increase the cut position index value (>100). If the cut position causes the label following the one just printed to be cut, decrease the cut position index value (<100). Syntax fp1 Parameters This table identifies the parameters for this format: 14245L-001 Rev. A Parameters Details p1 = Cut position index Cut position index measured in dots. Accepted Values: 070 to 130 Accepted Values: 100. EPL Programming Guide 5/30/07 EPL Commands fB fB Adjust Backup Position Description Use this command to provide precision tear, peel and cut placement to finetune the media positioning to compensate for differences in media and handling requirements. Mobile printers, such as the TR 220, ignore this command. Syntax fp1 Parameters This table identifies the parameters for this format: 5/30/07 Parameters Details p1 = Media position offset Media position offset measured in dots. Accepted Values: 0–255 Default Value: 0 EPL Programming Guide 14245L-001 Rev. A 97 98 EPL Commands FE FE End Form Store Description This command is used to end a form store sequence. Syntax FE Parameters There are no parameters for this format. Example • The form store sequence is started with the FS command. FS"FORMNAME"↵ ... FE↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands FI FI Print Form Information Description This command will cause the printer to print a list of all forms stored in memory. Syntax FI Parameters There are no parameters for this format. Example • This command will print a forms list. FI↵ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 99 100 EPL Commands FK FK Delete Form Description this command is used to delete forms from memory. Syntax FK [ “FORMNAME” | “*”] Parameters This table identifies the parameters for this format: Parameters Details “FORMNAME” By entering the name of a form, that form will be deleted from memory. • The namemay be up to 8 characters long. • Form names stored by the printer are case sensitive and will be stored exactly as entered on the FS command line; i.e. “FORM1”, “form1” and “FoRm1” are three different forms when stored into the printer or when retrieved by the user. • Deleting a single form requires the FK”FORMNAME” be issued twice for each form to be deleted. Some label generation programs re-issue forms (form delete and store) every time a label is printed which reduces flash memory life. “*” = Wild card By including an “*” (wild card), ALL forms will be deleted from memory. The FK”*” does not need to be issued twice to delete all forms. Example 1 • This example deletes the AFORM form. A second delete is requierd for flash printers. FK"AFORM"↵ FK"AFORM"↵ Example 2 • This example deletes all forms. FK"*"↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands FR FR Retrieve Form Description Use this command to retrieve a form that was previoiusly stored in memory. Syntax FR”FORMNAME” Parameters This table identifies the parameters for this format: Parameters Details “FORMNAME” This is the form name used when the form was stored. • The namemay be up to 8 characters long. • Form names stored by the printer are case sensitive and will be stored exactly as entered on the FS command line; i.e. “FORM1”, “form1” and “FoRm1” are three different forms when stored into the printer or when retrieved by the user. Example • This example retrieves the form named TEST1. FR"TEST1"↵ Note • To print a list of the forms currently stored in memory, use the F1 command. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 101 102 EPL Commands FS FS Store Form Description This command begins a form store sequence. • All commands following FS will be stored in form memory until the FE command is received, ending the form store process. • Delete a form prior to updating the form by using the FK command. If a form (with the same name) is already stored in memory, issuing the FS command will result in an error and the previously stored form is retained. • To print a list of the forms currently stored in memory, use the FI command. • Data stored within a form can not have the Null (0 dec. 00 hex.) character as part of any data within that form. • A form will not store if insufficient memory is available. See the M command for details on adjusting and configuring memory for forms, graphics and soft fonts. Syntax FS”FORMNAME” Parameters This table identifies the parameters for this format: Parameters Details “FORMNAME” This is the form name used when the form was stored. • The namemay be up to 8 characters long. • Form names stored by the printer are case sensitive and will be stored exactly as entered on the FS command line; i.e. “FORM1”, “form1” and “FoRm1” are three different forms when stored into the printer or when retrieved by the user. • Global commands such as EI, EK, ES, FI, FK, GI, GK, GM, M, N, P, TS, U, UE, UF, UG, Y, W, ?, ^@ should not be used in a form store sequence. Note • Form name, AUTOFR, is reserved for automatic, single form recall. See AUTOFR on page 48 for details. Example • FK"TESTFORM"↵ FS"TESTFORM"↵ : delete form “TESTFORM” : begins the form store sequence of the form “TESTFORM” V00,15,N,"Enter Product Name:"↵ B10,20,0,3,2,10,100,B,"998152.001"↵ A50,200,0,3,1,1,N,"Example Form"↵ A50,400,0,3,1,1,N,"Model Name: “V00↵ FE ↵ : ends form store sequence FI ↵ : prints list of stored forms 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands GG GG Print Graphics Description Use this command to print a PCX (format) graphic that has been previously stored in printer memory. Syntax GGp1,p2,{N”NAME” | Variable Data} Parameters This table identifies the parameters for this format: Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. “NAME” or Variable Data =Graphic name This is the graphic name used when the graphic was stored. This name can be supplied via variable data (V00 - V99). • The name may be up to 8 characters long. • Graphic names stored by the printer are case sensitive and will be stored exactly as entered with the GM command line; i.e. “GRAPHIC1”, “graphic1” and “graPHic1” are three different graphics when stored into the printer or when retrieved by the user. Example • This example FK"TESTFORM"↵ FS"TESTFORM"↵ : delete form “TESTFORM” : begins the form store sequence of the form “TESTFORM” V00,8,N,"Enter Graphic Name:"↵ GG50,50,V00↵ FE↵ : ends form store sequence FR"TESTFORM"↵ ?↵ LOGO1↵ P1↵ 5/30/07 : retrieves the form named TESTFORM : Download variables : Graphic name to be recalled and printed : Print one label with graphic LOGO1 EPL Programming Guide 14245L-001 Rev. A 103 104 EPL Commands GI GI Print Graphics Information Description This command will cause the printer to print a list of all graphics stored in memory. Syntax GI Parameters There are no parameters for this command. Example • This example will print a graphics list. GI↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands GK GK Delete Graphics Description Use this command to delete graphics from memory. Syntax GK {“NAME”|”*”} Parameters This table identifies the parameters for this format: Parameters Details “NAME” By entering the name of a graphic, that graphic will be deleted from memory. • Graphic names stored by the printer are case sensitive and will be stored exactly as entered with the GM command line; i.e. “LOGO1”, “logo1” and “LoGo1” are three different graphics when stored into the printer or when retrieved by the user. • Deleting a single graphic requires that the GK”FORMNAME” command string be issued twice for each form deleted. Some label generation programs reissue graphics (graphic delete and store) every time a label is printed which will reduce flash memory life. “*” = Wild card By including an “*” (wild card), ALL graphics will be deleted from memory. The GK”*” does not need to be issued twice to delete all graphics. Example 1 • This example deletes the graphic logo. A second delete is requierd for flash printers. GK"LOGO"↵ GK"LOGO"↵ Example 2 • This example deletes all graphics. GK"*"↵ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 105 106 EPL Commands GM GM Store Graphics Description Use this command to store PCX graphics files in memory. Syntax GM”NAME”p1 “DATA” Parameters This table identifies the parameters for this format: 14245L-001 Rev. A Parameters Details “NAME” = Graphic name This is the grahpic name that will be used when retrieving the stored graphic. • The name may be up to 8 characters long. • Graphic names stored by the printer are case sensitive and will be stored exactly as entered with the GM command line; i.e. “LOGO1”, “logo1” and “LoGo1” are three different graphics when stored into the printer or when retrieved by the user. • Deleting a single graphic requires that the GK”FORMNAME” command string be issued twice for each form deleted. Some label generation programs reissue graphics (graphic delete and store) every time a label is printed which will reduce flash memory life. p1 = File size in bytes Use the DOS DIR command to determine the exact file size. “DATA” =Graphic data Graphic data in 1-bit (black & white) PCX (binary data) format file. • A graphic will not store if sufficient memory is not allocated to graphic memory. See the M command for details on adjusting and configuring memory to store graphics (forms and soft fonts). • Verify the proper storage of the graphic with the GI command. EPL Programming Guide 5/30/07 EPL Commands GM Example 1 • GK"LOGO1"↵ : deletes graphic “LOGO1” Required : second delete graphic GK"LOGO1"↵ Required GM"LOGO1"584↵ : Prepares printer to receive graphic “LOGO1” DATA↵ : Data string in PCX format If using a DOS system, the PCX format file (binary data) portion can be sent to the printer using the DOS COPY command. For example, if you have a PCX file named LOGO1.PCX in your current directory, the appropriate command would be: COPY LOGO1.PCX PRN /b After downloading, the GI command can be used to verify that the graphic was successfully stored. Example 2 • First, create a text file “STOREIT.TXT” with an ASCII text editor, as follows: GK“WORLD”↵ GK“WORLD”↵ GM"WORLD"2004↵ Where WORLD is the name of the graphic and 2004 is the size (in bytes) of the PCX file. DO NOT add extra linefeeds to the STOREIT.TXT file. Next, at the DOS prompt, type: COPY STOREIT.TXT+WORLD.PCX PRN /b or use the Zebra Firmware Downloader from Windows OS download the STOREIT.TXT and WORLD.PCX in sequence to the printer. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 107 108 EPL Commands GW GW Direct Graphic Write Description Use this command to load binary graphic data directly into the Image Buffer memory for immediate printing. Theprinter does not store graphic data sent directly to the image buffer. The graphic data is lost when the image has finished printing, power is removed or the printer is reset. Commands that size (Q and q) or clear (N and M) the image buffer will also remove graphic image data. Syntax GWp1,p2,p3,p4,DATA Parameters This table identifies the parameters for this format: 14245L-001 Rev. A Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. p3 = Width of graphic Width of graphic in bytes. Eight (8) dots = one (1) byte of data. p4 = Length of graphic Length of graphic in dots (or print lines) DATA Raw binary data without graphic file formatting. Data must be in bytes. Multiply the width in bytes (p3) by the number of print lines (p4) for the total amount of graphic data. The printer automatically calculates the exact size of the data block based upon this formula. EPL Programming Guide 5/30/07 EPL Commands i i Asian Character Spacing Description Places an adjustable inter-character space between Asian font characters, fonts 8 and 9, only. The inter-character spacing gets multiplied with the text string by the selected font’s horizontal and vertical multiplier values. Syntax ip1 Parameters This table identifies the parameters for this format: Parameters Details p1 = Space in dots between Asian characters Accepted Values: 0-9 (dots) Default Value: 0 (dots or no space) (i) Command Parameter Set to Default (0 dots) 1 Character 1 Character (i) Command Parameter Set to 8 (8 dots) 1 Character 5/30/07 i=8 EPL Programming Guide 1 Character 14245L-001 Rev. A 109 110 EPL Commands I I Character Set Selection Description Use this command to select the appropriate character set for printing (and KDU display). Syntax Ip1,p2,p3 Parameters This table identifies the parameters for this format: 14245L-001 Rev. A Parameters Details p1 = Number of data bits Accepted Values: 8 = 8 bit data 7 = 7 bit data EPL Programming Guide 5/30/07 EPL Commands I Parameters p2 = Printer Codepage/Language Support p3 = KDU Countyr Code Details 8 Bit Data 7 Bit Data p2 Code Page Description p2 Description 0 DOS 437 English - US 0 USA 1 DOS 850 Latin 1 1 British 2 DOS 852 Latin 2 (Cyrillic II/Slavic) 2 German 3 DOS 860 Portuguese 3 French 4 DOS 863 French Canadian 4 Danish 5 DOS 865 Nordic 5 Italian 6 DOS 857 Turkish 6 Spanish 7 DOS 861 Icelandic 7 Swedish 8 DOS 862 Hebrew 8 Swiss 9 DOS 855 Cyrillic 10 DOS 866 Cyrillic CIS 1 11 DOS 737 Greek 12 DOS 851 Greek 1 13 DOS 869 Greek 2 A Windows 1252 Latin 1 B Windows 1250 Latin 2 C Windows 1251 Cyrillic D Windows 1253 Greek E Windows 1254 Turkish F Windows 1255 Hebrew 8 bit data only. KDU Country Code (8 bit only) 032 Belgium 049 Germany 027 S.Africa 002 Canada 031 Netherl’ds 034 Spain 045 Denmark 039 Italy 046 Sweden 358 Finland 003 Latin Am. 041 Swizerl’d 033 France 047 Norway 044 U.K. 351 Portugal 001 U.S.A. The default setting is I8,0,001. See Appendix B, Character References for EPL2 standard font character samples. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 111 112 EPL Commands JB JB Disable Top Of Form Backup Description This command disables the Top Of Form Backup feature when printing multiple labels. At power up, Top Of Form Backup will be enabled. Syntax JB Parameters Thre are no parameters for this format. Example • JB↵ Note • With the JB command enabled, the first label will backup to the Top Of Form before printing. This preserves the first label which has stopped approximately one-half inch from the print head. This is the label’s tear away point as set by the previous print operation. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands JC JC Disable Top Of Form Backup- All Cases Description This command disables the Top Of Form Backup feature for all operations. Use this command for liner-less printing and special media cutting modes. This command only is available in the 2824, 2844, and 3842 desktop printer models at this time. Syntax JC Parameters Thre are no parameters for this format. Example • JC↵ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 113 114 EPL Commands JF JF Enable Top Of Form Backup Description This command enables the Top Of Form Backup feature and presents the last label of a batch print operation. Upon request initiating the printing of the next form (or batch), the last label backs up the Top Of Form before printing the next label. Syntax JF Parameters Thre are no parameters for this format. Example • JF↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands LE LE Line Draw Exclusive OR Description Use this command to draw lines with an “Exclusive OR” function. Any area, line, image or field that this line intersects or overlays will have the image reversed or inverted (sometimes known as reverse video or a negative image). In other words, all black will be reversed to white and all white will be reversed to black within the line’s area (width and length). Syntax LEp1,p2,p3,p4 Parameters This table identifies the parameters for this format: Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. p3 = Horizontal length Horizontal length in dots. p4 = Vertical length Vertical length in dots. Example • N↵ LE50,200,400,20↵ LE200,50,20,400↵ P1↵ will produce this label: 5/30/07 : : : : EPL Programming Guide clear image buffer draw a line draw another line print one label 14245L-001 Rev. A 115 116 EPL Commands LO LO Line Draw Black Description Use this command to draw black lines, overwriting previous information. Syntax LOp1,p2,p3,p4 Parameters This table identifies the parameters for this format: Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. p3 = Horizontal length Horizontal length in dots. p4 = Vertical length Vertical length in dots. Example • N↵ LO50,200,400,20↵ LO200,50,20,400↵ P1↵ will produce this label: 14245L-001 Rev. A : : : : EPL Programming Guide clear image buffer draw a line draw another line print one label 5/30/07 EPL Commands LS LS Line Draw Diagonal Description Use this command to draw diagonal black lines, overwriting previous information. Syntax LSp1,p2,p3,p4,p5 Parameters This table identifies the parameters for this format: Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. p3 = Horizontal length Horizontal length in dots. p4 = Vertical length Vertical length in dots. p5 = Vertical end position Vertical end position (Y) in dots. Example • N↵ LS10,10,20,200,200↵ P1↵ will produce this label: 5/30/07 : clear image buffer : draw a diagonal line : print one label EPL Programming Guide 14245L-001 Rev. A 117 118 EPL Commands LW LW Line Draw White Description Use this command to draw white lines, effectively erasing previous information. Syntax LWp1,p2,p3,p4 Parameters This table identifies the parameters for this format: Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. p3 = Horizontal length Horizontal length in dots. p4 = Vertical length Vertical length in dots. Example • N↵ LO50,100,400,20↵ LO50,200,400,20↵ LO50,300,400,20↵ LW200,50,20,400↵ P1↵ will produce this label: 14245L-001 Rev. A : : : : : clear image buffer draw black line draw another black line draw another black line draw a white line over all 3 black lines : print 1 label EPL Programming Guide 5/30/07 EPL Commands M M Memory Allocation Description Printers except LP 2348 and LP 2348 Plus, with firmware version 4.32 and above ignore this command. Use this command to set the size of form memory. The reminder of the form storage memory will be shared by soft fonts and graphics data. Syntax Mp1,p2,p3 Parameters This table identifies the parameters for this format: Parameters Details p1 = Parameter ignored Parameter ignored, but required to process. Represents Image buffer size in whole KBytes. p2 = Form(s) memory size Form(s) memory size in whole KBytes. The parameter, p2 (form memory size), inversely effects the size of the shared graphics/soft fonts memory. p3 = Parameter ignored Parameter ignored, but required to process. Graphics (and soft font) memory size in whole Kbytes. If the M command is issued, then all three parameters must be present. Note • Available memory and the current allocation of memory can be displayed with the U command or an AutoSense procedure, see the printer’s user manual for details. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 119 120 EPL Commands N N Clear Image Buffer Description This command clears the image buffer prior to building a new label image. Syntax N Parameters There are no parameters for this format. Considerations: • Do not use the N command within stored forms. • All printer configuration commands should be issued prior to issuing the N command to begin building the image for printing within the image buffer. • Always send a Line Feed (LF) prior to the N command to ensure that previous data in the command buffer has cleared and the printer is initialized and ready to accept commands. Example • ↵ N↵ 14245L-001 Rev. A : activates command processing : clears the image buffer EPL Programming Guide 5/30/07 EPL Commands o o Cancel Software Options Description This command allows the user to cancel most printer customization parameters set by o series commands. Parameters set by the following commands are canceled and returned to default operation: • oH • oM • oE Syntax o Parameters There are no parameters for this format. The o command is a global printer command. • It can not be issued inside of a form. • It must be issued prior to issuing a text or bar code command (and printing). 5/30/07 EPL Programming Guide 14245L-001 Rev. A 121 122 EPL Commands oB oB Cancel Auto Bar Code Optimization Description This command allows the advanced programmer to disable bar code optimization for rotated (90° & 270°) bar codes. Syntax oB Parameters Thre are no parameters for this format. The oB command is a global printer command. • It can not be issued inside of a form. • It must be issued prior to issuing a bar code command (and printing). To reapply bar code defaults, issue a o (small letter ¡°o¡±) command. See page C-90 for important details on the effects of using the o command. Reset the printer with a ^@ command with flash firmware printers or cycle printer power to clear the oB command and return the printer to normal operation. Important • Zebra Technologies Corporation does not warrant, support, or endorse the use of bar codes generated by the printer after a oB command has been issued. Zebra Technologies Corporation does not support this feature other than with the information supplied in this document. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands oE oE Line Mode Font Substitution Description This command is a Page Mode (EPL2) command that allows the printer to set alternate Line Mode font character sets. The fonts are activated by the oE command and are intended for EPL1 emulation. Mobile printers, such as the TR 220, ignore this command. Syntax oEp1,p2,p3,p4,p5 Parameters This table identifies the parameters for this format: Parameters Details p1 = 5 x 7 bitmap font 5 x 7 bitmap font - Normal (CCSET4) Line Mode EPL1 Compatibility Font A0 Total character area is 8 x 11 dots p2 = 5 x 7 bitmap font 5 x 7 bitmap font - Bold (CCSET4) Line Mode EPL1 Compatibility Font A0 Total character area is 8 x 11 dots p3 = 5 x 7 bitmap font 5 x 7 bitmap font - Doubled (CCSET4) Line Mode EPL1 Compatibility Font A0 Total character size is 8 x 11 dots p4 = 14 x 22 bitmap font 14 x 22 bitmap font - (CCSET1) Line Mode EPL1 Compatibility Font A Total character area is 16 x 26 dots p5 = 10 x 18 bitmap font 10 x 18 bitmap font - (CCSET3) Line Mode EPL1 Compatibility Font A Total character area is 12 x 22 dots • Parameters p1-p5 are preloaded soft fonts. • Parameters p1-p5 must be all be lower case alpha soft fonts. See the ES command on page 91 for more details on soft fonts. • The EPL2 font sets 2 & 4 can be restored as the default Line Mode fonts by sending the o command without a parameter. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 123 124 EPL Commands oH oH Macro PDF Offset Description Use this command to place addition secondary, associated Macro PDF symbols for the continuation of data greater than a single PDF 417 bar code can store. This command must precede any PDF 417 bar code commands in order to print Macro PDF (multiple bar code) symbols from a single b command’s data field. Syntax oHp1,p2 Parameters This table identifies the parameters for this format: 14245L-001 Rev. A Parameters Details p1 = Horizontal offset position Horizontal offset position (X) in dots of the next Macro PDF bar code symbol. p2 = Vertical offset position Vertical offset position (Y) in dots of the next Macro PDF bar code symbol. EPL Programming Guide 5/30/07 EPL Commands oH Example • N↵ q784↵ Q1215,24↵ R0,0↵ oH0,500↵ ø N↵ b80,100,P,700,600,x2,y7,l100,r100,f0,s5,"\↵ Fourscore and seven years ago our fathers...↵ < > ... and that government of the people, by the people, for the people shall not perish from the earth.↵ “↵ P↵ will produce this label: 5/30/07 EPL Programming Guide 14245L-001 Rev. A 125 126 EPL Commands oM oM Disable Initial Esc Sequence Feed Description This command disables the automatic label calibration routine executed by the printer upon receiving the first escape command sequence from the Windows printer driver. The printer normally measures a single label and sets the top of form prior to printing the first label after a power-up reset. The Windows™ printer driver issues escape sequences when printing. This command’s primary use is to save preprinted forms such as serialized labels, tags or tickets. Mobile printers, such as the TR 220, ignore this command. Syntax oM This command must be issued prior to printing with the Windows driver’s or any other Escape (esc) mode printing operation. To reinitialize label calibration, issue a o (111 dec. or 6F hex.) command. Parameters There are no parameters for this format. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands oR oR Character Substitution (Euro) Description This command allows the advanced programmer to substitute the Euro currency character for any ASCII character in printer resident font numbers 1-4. The second function this command supports is the zero character style toggling between a plain zero character and a zero with a slash. Character substitution settings are stored in the printers non-volatile 'flash' memory. The original character can be restored by sending the oR command without a parameter. Syntax oR[p1,p2] Parameters This table identifies the parameters for this format: Parameters Details p1 = E If the p2 parameter is not provided, then the Euro character will map to code page position 213 decimal (D5 hexadecimal) for all code pages. p1 = 0 (zero) Toggles the zero character: slash — no slash (out of box default) p2 = Decimal number Accepted Values: 0 to 255 The active code page’s ASCII character map position to be replaced by the Euro character. The Euro character will be active in this map position for all code pages. See the I command for details on code page selection. None = No parameters (p1/p2) No Parameters (p1/p2) resets to all code pages to original default character mapping. Optionally, to reapply normal character operations, issue a o (111 dec. or 6F hex.) command. See page 121 for important details on the effects of using this command. Note • The Euro character is not supported in Font 5 character set. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 127 128 EPL Commands oW oW Customize Bar Code Parameters Description This command allows the advanced programmer to modify specific bar code parameters to exceed the specified bar code’s design tolerances, i.e. reduce the bar code size. Note • Using the oW command may cause bar codes to become unreadable by some or all bar code scanners. Syntax oWp1,p2,p3,p4,p5 Parameters This table identifies the parameters for this format: Parameters Details p1 = Initial width narrow white bar Default Value: 2 p2 = Initial width narrow black bar Default Value: 2 p3 = Initial width wide white bar Default Value: 4 p4 = Initial width wide black bar Default Value: 4 p5 = Initial bar code gap Default Value: 3 The oW command is a global printer command. • They can not be issued inside of a form. • They must be issued prior to issuing a bar code command (and printing). • Use only one bar code format. Using more than one bar code may cause unpredictable results or operation. • Issue all 5 command parameters (p1-5 ). Use the default parameter values as place holders. • Bar code printed with this command should be printed in the picket fence orientation (0° & 180° rotations) to maximize scanning. Reset the printer with a ^@ or o commands with flash firmware printers or cycle printer power to clear theoWcommand and return the printer to normal operation. See page C-90 for important details on the effects of using the o command. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands oW The B command parameters p5 & p6 must beset to 0 to use bar codes customized with this command. Note • The oW command has been tested for parameter functionality for Bar Code 39 only. The oW command may also function with Codabar and Interleaved 2 of 5 bar code, but they have not been functionally verified for this command. Important • Zebra Technologies Corporation does not warrant, support, or endorse the use of bar codes generated by the printer after aoWcommand has been issued. Zebra Technologies Corporation does not support this feature other than with the information supplied in this document. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 129 130 EPL Commands O O Hardware Options Description Use this command to select various printer options. Options available vary by printer configuration. Options selected and enabled in a printer can be verified by checking the printer configuration printout, Dump Mode printer status label. See the U command on page 146 and the Explanation of the Status Printout on page 34. Mobile printers, such as the TR 220, ignore this command. Syntax O[C[p1],D,P,L,S,F] Parameters This table identifies the parameters for this format: 14245L-001 Rev. A Parameters Details C = Enable optional Label Liner Cutter The cutter will cut at the end of each form as specified by the Q command. Cp1 = Batch print labels and liner cut p1p1 = Sets the number of labels to print prior to cut. If a number between 1 - 255 is specified for p1, the printer will cut after the specified number of labels have been printed. If b is specified for p1, the “batch print & cut” feature is enabled. This feature uses the P command to control cutter operation. D = Enable direct Thermal Mode Enable Direct Thermal Mode, use this option when using direct thermal media in a thermal transfer printer. d = Status Not a command, this is a status only. Out of box default Direct Thermal Mode setting used in a 2844, 2824 or 3842 thermal transfer printer's and is displayed in the Dump Mode status printout. Changing the printer to thermal transfer mode or when the printer detects a transfer ribbon will cause this option parameter to permanently be removed from the status printout. P = Enable label taken sensor Enable label taken sensor for the Label Dispense (Peel) Mode. L = Enable printer’s Feed button Enable the printer's Feed button for Tap to Print operation in the Label Dispense (Peel) Mode. The printer will present each label and wait for a tap of the Feed button before printing the next label. Use this mode when printing multiple copies of liner-free labels. EPL Programming Guide 5/30/07 EPL Commands O Parameters Details S = Reverse sensor operation Reverse the Transmissive (Gap) Sensor’s normal operation. Fp1 = Form Feed Setting p1 = Sets the type of operation the feed button . f = Default, normal operation. Tap to feed. r = Reprint last label printed. i = Ignore the feed button. Example • O↵ OC↵ OD↵ OCb↵ … P5↵ 5/30/07 : disables all options. : enables cutter only, labels are cut after each : label is printed, disables all other options : enables direct thermal mode on thermal transfer : printers, disables all other options : labels are cut after a batch of five has printed, : disables all other options : Sets the number of labels to print before the cut EPL Programming Guide 14245L-001 Rev. A 131 132 EPL Commands OEPL1 OEPL1 Set Line Mode Description This command is used to switch the printer operating mode from Page Mode (EPL2) to Line Mode (EPL1 emulation). Line Mode configuration setting is retained after reset has been issued or power has been cycled. Mobile printers, such as the TR 220, ignore this command. Syntax OEPL1 Parameters There are no parameters for this format. Example • OEPL1↵ Returning to Page Mode The Line Mode command EPL2 can be sent to the printer to return the printer to Page (EPL2) Mode operation. The EPL2 command is preceded by an ESCape (27 dec or 1Bh) character and followed by a line feed (LF - 10 dec or 0A hex), a carriage return (CR - 13 dec or 0D hex) or CR/LF. Example • ←EPL2↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands P P Print Description Use this command to print the contents of the image buffer. Note • The P command cannot be used inside of a stored form sequence. For automatic printing of stored forms, use the PA command. Syntax Pp1,[p2] Parameters This table identifies the parameters for this format: Parameters Details p1 = Number of label sets. Accepted Values: 1 to 65535 p2 = Number of copies of each labael Accepted Values: 1 to 65535 Number of copies of each label (used in combination with counters to print multiple copies of the same label). Example • P1↵ P2,1↵ P5,2↵ 5/30/07 : prints one label set : prints 2 label sets of one label each : prints 5 label sets of 2 labels each EPL Programming Guide 14245L-001 Rev. A 133 134 EPL Commands PA PA Print Automatic Description Use this command in a stored form sequence to automatically print the form (as soon as all variable data has been supplied). Syntax PAp1,[p2] Parameters This table identifies the parameters for this format: Parameters Details p1 = Number of label sets. Can be variable data. Accepted Values: 1 to 9999 p2 = Number of copies of the same labael Can be variable data. Accepted Values: 1 to 9999 Sets the number of copies of each label (used in combination with counters) to print multiple copies of the same label. This value is only set when using counters. Example • FK"1"↵ FS"1"↵ V00,10,N,"prompt:"↵ V01,1,N,"prompt:"↵ V02,4,N,"prompt:"↵ A24,24,0,4,1,1,N,V00↵ PAV01,V02↵ FE↵ delete form named “1" start form store sequence define variable 00 define variable 01 define variable 02 write a line of text including variable : print 1 label automatically : end form store sequence FR"1"↵ ?↵ This Is Text↵ 3↵ : : : : 2↵ 14245L-001 Rev. A : : : : : : retrieve form “1" get variables data for V00 data for V01= p1- number of sets : data for V02= p2 - number of copies EPL Programming Guide 5/30/07 EPL Commands q q Set Label Width Description Use this command to set the width of the printable area of the media. Syntax qp1 This table identifies the parameters for this format: Parameters Details p1 = The width of the label measured in dots. The q command will cause the image buffer to reformat and position to match the selected label width (p1). Figure 5 • Image Buffer Positioning—Center Aligned Printers 3ULQW+HDG 0D[ ,PDJH %XIIHU 0D[ ,PDJH %XIIHU 3ULQWDEOH $UHD T &HQWHU$OLJQPHQW Figure 6 • Image buffer Positioning—Left Aligned Printers 3ULQW+HDG 3ULQWDEOH $UHD ,PDJH %XIIHU 4 T /HIW$OLJQPHQW(GJH 5/30/07 EPL Programming Guide 14245L-001 Rev. A 135 136 EPL Commands q Notes • For all EPL desktop printers, this command will automatically set the left margin according to the following rules: (print head width -label width) / 2 The q value affects the available print width. Minimizing the q value will maximize the print length and print speed (double buffering). If the R Command (Reference Point) is sent after this command, the image buffer will be automatically reformatted to match the width of the print head and is offset by the R command specified image buffer starting point, nullifying the q command. Example • q416↵ 14245L-001 Rev. A : sets label width to 416 dots wide EPL Programming Guide 5/30/07 EPL Commands Q Q Set Form Length Description Use this command to set the form and gap length or black line thickness when using the transmissive (gap) sensor, black line sensor, or for setting the printer into the continuous media print mode. The Q command will cause the printer to recalculate and reformat image buffer. Syntax Qp1,p2,[±p3] Parameters This table identifies the parameters for this format: Parameters Details p1 = Label length measured in dots Default Value: Set by the AutoSense of media Accepted Values: 0-65535 • Distance between edges of the label or black line marks. • For continuous mode, the p1 parameter sets the feed distance between the end of one form and beginning of the next. p2 = Gap length or thickness of black line Accepted Values: 16-240 (dots) for 203 dpi printers 18-240 (dots) for 300dpi printers Gap Mode By default, the printer is in Gap mode and parameters are set with the media AutoSense. Black Line Mode Set p2 to B plus black line thickness in dots. See the Gap mode range. Continuous Media Mode Set p2 to 0 (zero)The transmissive (gap) sensor will beused to detect the end of media. p3 = Offset length measured in dots Required for black line mode operation. Optional for Gap detect or continuous media modes. Use only positive offset values. AutoSense routine does not detect black line or continuous media. All EPL2 printers have a transmissive (gap) sensor designed to detect the top of each label or tag. It does this in one of two ways: • Sensing through the label liner at the gap between labels. • Looking through a hole (notch) in the tag. Printers equipped with a black line sensor can determine the top of each label or tag by sensing a “black line” preprinted on the media backing. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 137 138 EPL Commands Q Sensor location is important when selecting the proper of label or tag type for printing. See the printer’s user manual for specific information on alignment, adjustment, and position of the transmissive (gap) or reflective (black line) sensors. If the label size is not set properly, the printer may print off the edge of the label or tag and onto the backing or platen roller. Repeated printing off the edge of the label can cause excessive print head wear. Maintain a minimum margin of 0.04 inches (1 mm) on all sides of the label. Setting the label size to large can cause the printer to skip labels. Example 1 • Standard Label p1 p2 Where: p1 = 20.mm (160 dots) p2 = 3.0 mm (24 dots) The Q command would be: Q160,24↵ Example 2 • Butterfly Label p1 p2 p3 Where: p1 = 12.5 mm (100 dots) p2 = 3.0 mm (24 dots) p3 = 3.0 mm (24 dots) The Q command would be: Q100,24+24↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands Q Example 3 • Black Line on Perforation p1 p2 Perforation p3 Where: p1 = p2 = p3 = The Q command would be: Q100,24+24↵ Example 4 • Black Line Between Perforation p1 Perforation p2 p3 Where: p1 = p2 = p3 = The Q command would be: Q100,24+24↵ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 139 140 EPL Commands r r Set Double Buffer Mode Description Use this command to disable or reenable the double buffer image (label) printing. The double buffer feature is a automatically tested and set by the q and Q commands. Mobile printers, such as the TR 220, ignore this command and automatically set the printer to single buffer mode. Syntax rp1 Parameters This table identifies the parameters for this format: 14245L-001 Rev. A Parameters Details p1 = Enable/disable double buffer mode Accepted Values: N = Disable double buffer mode Y = Re-enable the double buffer mode if the printer memory supports the image buffer size set by Q and q parameters Note • The rN command must follow the q and Q commands in a form (label) program. Verify the image buffer status with the U command(s). See Explanation of the Status Printout on page 34 for a sample of the Dump Mode Printout. EPL Programming Guide 5/30/07 EPL Commands R R Set Reference Point Description Use this command to move the reference point for the X and Y axes. All horizontal and vertical measurements in other commands use the setting for R as the origin for measurements. Use the R command as an alternative to sending the q command to position (center) labels that are narrower than the print head. The R command interacts with image buffer setting, as follows: • The R command forces the printer to use the full width of the print head as the width of the image buffer. The R command overrides the q commands print width setting. • Rotate the image buffer with the Z command to establish top and left margins (ZT) or the bottom and right margins (ZB). • When positioned correctly, prevents printing off two (2) edges of the label opposite the 0,0 reference point. Syntax Rp1,p2 Parameters This table identifies the parameters for this format: Parameters Details p1 =Horizontal (left) margin Horizontal (left) margin measured in dots. p2 = Vertical (top) margin measured in dots. Vertical (top) margin measured in dots. Note • • • 5/30/07 Use the Q and R commands together for the easiest method of positioning form elements in the print image in left-aligned table top printers. Repeated printing off the edge of the label can cause excessive print head wear. EPL Programming Guide 14245L-001 Rev. A 141 142 EPL Commands S S Speed Select Description Use this command to select the print speed. Mobile printers, such as the TR 220, ignore this command and automatically set speed to optimize battery use. Syntax Sp1 Parameters This table identifies the parameters for this format: Parameters Details p1 = Speed select value Model Value Speed 2722 0 1.0 ips (25 mm/s) 2742 1 1.5 ips (37 mm/s) 2 2.0 ips (50 mm/s) 2824 1 1.5 ips (37 mm/s) 2844 2 2.0 ips (50 mm/s) 3 2.5 ips (63 mm/s) 4 3.5 ips (83 mm/s) 1 1.5 ips (37 mm/s) 2 2.0 ips (50 mm/s) 3 2.5 ips (63 mm/s) 2746 2 2.0 ips (50 mm/s) 2746e 3 3.0 ips (50 mm/s) 4 4.0 ips (50 mm/s) 5 5.0 ips (50 mm/s) 6 6.0 ips (50 mm/s) 1 1.0 ips (25 mm/s) 2 2.0 ips (50 mm/s) 3 3.0 ips (50 mm/s) 4 4.0 ips (50 mm/s) 3742 3842 2443 (Orion) 2348 2684 (Strata) Example • This example selects 2 ips (50 mmps). S2↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands TD TD Date Recall & Format Layout Description Use this command to define the date format and print date data. The TD variable is inserted within a Text or Bar Code command's DATA parameter to print the date. The TD variable supports offsetting day by up to 253 days (see examples below for usage). This command only works in printers equipped with the Real Time Clock time and date option. Power-Up Default Format - mn-dd-y4 Syntax TDp1[|p2|p3] Parameters This table identifies the parameters for this format: Parameters Details p1 = The parameters describe the format of the date display. At lease one parameter must be supplied. Each parameter can be any of the acceptable values listed below. p2 = p3 = | = Separator character. Value Description y2 Year displayed as 2 digits (07) y4 Year displayed as 4 digits (2007) me Month displayed as 3 letters (JAN) mn Month displayed as 2 digits (01) dd Day displayed as 2 digits (15) Accepted Values: Any ASCII character value between 032 and 063. The separator character is printed between the results of each of the supplied parameters. Example • In this example, the current date is January 15, 2000. TDy2/me/dd↵ : 00/JAN/15 TDdd-me-y4↵ : 15-JAN-2000 TDdd,mn,y4↵ : 15,01,2000 TDdd/mn/y2↵ : 15/09/00 A100,100,0,4,1,2,N,"Today is"TD↵: Today is 15/09/00 A100,200,0,4,1,2,N,"Next Week-"TD+07↵: Next Week-22/09/00 A100,300,0,4,1,2,N,"Next Month-"TD+30↵: Next Month-15/10/00 A100,400,0,4,1,2,N,"Two Months-"TD+61↵: Two Months-15/11/00 5/30/07 EPL Programming Guide 14245L-001 Rev. A 143 144 EPL Commands TS TS Set Real Time Clock Description Use this command to set the time and date in printers equipped with the Real Time Clock option. Syntax TSp1,p2,p3,p4,p5,p6 Parameters This table identifies the parameters for this format: Parameters Details p1 = Month Accepted Values: 01–12 p2 = Day Accepted Values: 01–31 p3 = Year Value is equivalent to the last two digits of Year (e.g. 95) Accepted Values: 90-99 (to indicate 1990-1999) 00-89 (to indicate 2000-2089) p4 = Hour Shown in 24 hour format. Accepted Values: 00–23 p5 = Minutes Accepted Values: 00–59 p6 = Seconds Accepted Values: 00–59 Example • In this example, the current date is January 15, 2000. TS01,01,95,01,00,00↵ TS12,31,01,15,31,00↵ 14245L-001 Rev. A :sets the date to Jan. 1, 1995 and the time to 1:00 a.m. : sets the date to Dec. 31, 2001 and the time to 3:31 p.m. EPL Programming Guide 5/30/07 EPL Commands TT TT Time Recall & Format Layout Description Use this command to define the time format and print time data. The TT variable is inserted within a Text or Bar Code command's DATA parameter to print the time. This command works only in printers equipped with the Real Time Clock (RTC) time and date option. Syntax TTp1[|p2|p3][+] Parameters This table identifies the parameters for this format: Parameters Details p1, p2, p3 = h, m, or s These parameters describe the format of the time display. • At lease one parameter must be supplied. • Each parameter can be any of the values h, m, or s and are described below. h = Hours displayed as 2 digits (e.g. 01) m = Minutes displayed as 2 digits (e.g. 15) s = Seconds displayed as 2 digits (e.g. 00) Default Value: h:m:s (power-up default format) + = Enable 12 Hour clock format Appending a + to the end of the command string selects 12 hour clock mode. The times will display with an “AM” or “PM” indicator. Default (no +) = 24 hour clock mode | The separator may be any ASCII character value between 032 and 063. The separator character is printed between the results of each of the supplied parameters. = Separator character Example • If the current time is 1:25 p.m.: TTh:m:s+↵ TTh,m↵ TTh+↵ When printing the following: : 01:25:00PM : 13,25 : 01 PM N↵ TTh:m:s+↵ A100,500,0,4,1,2,N,"Current Time↵: "TT A100,600,0,4,1,2,N,"+ 1Hr↵ "TT+60 A100,700,0,4,1,2,N,"+ 12hrs↵: "TT+720 P1↵ the result will be similar to this: Current Time : 01:25:35PM +1Hr : 02:25:35PM +12Hrs : 01:25:35PM 5/30/07 EPL Programming Guide 14245L-001 Rev. A 145 146 EPL Commands U U Print Configuration (General) Description Use this command to print the current printer configuration for page mode printing. The printout is the same the Dump Mode printout initiated by the printer’s AutoSense routine. The printer does not enter Dump Mode. See Explanation of the Status Printout on page 34 for a description of this printout. Syntax U Parameters There are no parameters for this format. Example • The configuration label below is produced by this command: U↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands UA UA Enable Clear Label Counter Mode Description This command sets the printer to clear (empty) the print buffer if a media out condition is detected. A power cycle, reset, or UB command will clear this setting. Normal (default) operation for the printer is to resume printing if the empty roll is replaced with new roll (or ribbon) and finish print any labels in the process of printing prior to a media out condition, including batch print jobs. Syntax UA Parameters There are no parameters for this format. Example • UA↵ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 147 148 EPL Commands UB UB Reset Label Counter Mode Description Use this command to clear the UA command and restore the default setting to allow the printer to resume printing a batch job if a paper empty occurs. The page mode (EPL2) printer, by default, will resume printing if the empty roll is replaced with new roll (or ribbon) and finish a batch print job. Syntax UB Parameters There are no parameters for this format. Example • UB↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands UE UE External Font Information Inquiry Description This command will cause the printer to send information about external fonts currently stored in the printer back to the host. The printer will send the number of external fonts stored and each font’s name, height and direction, to the host through the RS-232 port. Syntax UE Parameters There are no parameters for this format. Example • UE↵ will produce: ### A,xxx,y ... ... ... A,xxx,y 5/30/07 : : : : : number of external fonts first font A=fontname xxx=font height in dots y=direction (0=0°, 1=90°, 2=both) : last font EPL Programming Guide 14245L-001 Rev. A 149 150 EPL Commands UF UF Form Information Inquiry Description This command will cause the printer to send information about forms currently stored in the printer back to the host. Syntax UF Parameters There are no parameters for this format. Example • UF↵ will produce: ### FORMNAME1 FORMNAME2 ... FORMNAMEn 14245L-001 Rev. A : number of forms : first form name : second form name : last form name EPL Programming Guide 5/30/07 EPL Commands UG UG Graphics Information Inquiry Description This command will cause the printer to send information about graphics currently stored in the printer back to the host. Syntax UG Parameters There are no parameters for this format. Example • UG↵ will produce: ### GRAPHICNAME1 GRAPHICNAME2 ... GRAPHICNAMEn 5/30/07 : number of graphics : first graphic name : second graphic name : last graphic name EPL Programming Guide 14245L-001 Rev. A 151 152 EPL Commands UI UI Host Prompts/Codepage Inquiry Description This command will cause the printer to enable prompts to be sent to the host and it will send the currently selected codepage to the host through the RS-232 port. This command also disables software flow control (XON/XOFF). Hardware flow control is not disabled (DTR/CTS). To restart software flow control a reset (^@ command) or power must be recycled. See also the I and U commands. Syntax UIp1,p2,p3 Parameters This table identifies the parameters for this format: Parameters Details The printer will send information about the currently selected code page back to the host in the following format: p1 Number of data bits. p2 Code page. p3 Country code. Note • The KDU automatically sends this command each time power is applied. Example • UI↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands UM UM Codepage & Memory Inquiry Description This command will cause the printer to send to the host the currently selected codepage and memory status through the RS-232 port. This command also disables software flow control (XON/XOFF). Hardware flow control is not disabled (DTR/CTS). To restart software flow control a reset (^@ command) or power must be recycled. See also the I, M, U, UI and UP commands. Syntax UMp1,p2,p3,p4,p5,p6,p7,p8 Parameters This table identifies the parameters for this format: Parameters Details p1 Image buffer size in KBytes. p2 Form memory allocation size in KBytes. p3 Form memory free in KBytes. p4 Graphic memory allocation size in KBytes. p5 Graphic memory free in KBytes. p6 External font memory allocation size in KBytes. p7 External font memory free in KBytes. p8 Appends a response in the UI command data format. See the UI command on page 152. Example • UM↵ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 153 154 EPL Commands UN UN Disable Error Reporting Description Cancels US command. Syntax UN Parameters There are no parameters for this format. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands UP UP Codepage & Memory Inquiry/Print Description This command will cause the printer to print and send the currently selected codepage and memory status to the host through the RS-232 port. This command also disables software flow control (XON/XOFF). Hardware flow control is not disabled (DTR/CTS). To restart software flow control a reset (^@ command) or power must be recycled. See also the I, M, U, UI and UM commands. Syntax UP The printer will send information about the currently selected code page and memory status back to the host followed by printing the current printer configuration. For an example of the configuration printout, see the U command. The format of data sent to the host is as follows: UPp1,p2,p3,p4,p5,p6,p7,p8,p9 Parameters This table identifies the parameters for this format: Parameters Details p1 Image buffer size in KBytes. p2 Form memory allocation size in KBytes. p3 Form memory free in KBytes. p4 Graphic memory allocation size in KBytes. p5 Graphic memory free in KBytes. p6 External font memory allocation size in KBytes. p7 External font memory free in KBytes. p8 Appends a response in the UI command data format. See the UI command on page 152. Example • Up↵ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 155 156 EPL Commands UQ UQ Configuration Inquiry Description Use this command to send the printer configuration information back to the host via the serial port. The printer will send the printer configuration, line by line, in ASCII to the host through the RS-232 port. The information matches the configuration information printed in final phase of the printer’s AutoSense routine, the Dump Mode Printout or the U command printout. The information and number of lines of data sent by the printer will vary from printer to printer depending upon the type of printer and options installed. Syntax UQ Parameters There are no parameters for this format. Example • UQ↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands US US Enable Error Reporting Description Use this command to enable the printer’s status reporting feature. • Serial Port • If an error occurs, the printer will send a NACK(0x15), followed by the error number, to the computer. • If no errors occur, the printer will echo ACK(0x6) after each label is printed or removed if in dispense (peel) mode. • If paper or ribbon empty occurs, the printer will send, through the serial port, a”-07” and “Pnnn” where nnn is the number of labels remaining to print. • Parallel Port • If an error occurs, the printer will print the error number and the printer’s indicator(s) LED will indicate an error condition. See the individual printer’s user manual for details. • Mobile Printers Only (TR220) • Additionally enables command error reporting via printer’s status indicator. The indicator is turned off by default for this printer only. Note • The printer’s default setting is disabled error reporting. If enabled, use the UN command to disable error reporting. Syntax US[p1] 5/30/07 EPL Programming Guide 14245L-001 Rev. A 157 158 EPL Commands US Parameters This table identifies the parameters for this format: Parameters Details p1 = 1 (Optional Parameter) If no errors occur, the printer will echo ACK(0x6) after each label that is successfully printed/dispensed. Code 14245L-001 Rev. A Error/Status Description 00 No Error 01 Syntax Error 02 Object Exceeded Label Border 03 Bar Code Data Length Error (e.g.: EAN-13 is a 12 or 1 digit only) 04 Insufficient Memory to Store Data 05 Memory Configuration Error 06 RS-232 Interface Error 07 Paper or Ribbon Empty 08 Duplicate Name: Form, Graphic or Soft Font 09 Name Not Found: Form, Graphic or Soft Font 10 Not in Data Entry Mode (See ? Command) 11 Printhead Up (Open) 12 Pause Mode or Paused in Peel Mode 13 Mobile Printers: Print head too hot 14 Mobile Printers: Motor too hot 15 Mobile Printers: Battery low warning ( 40%) 16 Mobile Printers: Battery low limit ( 20%) 50 Printer Busy - Processing Print Job 84 Media Error or Blackline not detected 93 PDF-417 coded data too large to fit in bar code EPL Programming Guide 5/30/07 EPL Commands UT UT Enable Alternate Error Reporting Description Use this command to enable the printer’s status alternate reporting feature. • Serial Port • If an error occurs, the printer will send a NACK(0x15), followed by the error number, to the computer. • If no errors occur, the printer will echo ACK(0x6) after last line of the current label has been rasterized. • The printer will send a DLE(0x10) when the label is dispensed. • If paper or ribbon empty occurs, the printer will send, through the serial port, a ”-07”, “Pnnn” where nnn is the number of labels remaining to print. (Same as US1 command) • The UT command (when compared to the US1 command) then adds a "Lyyyyy" to the end, where yyyyy is the number of unprinted raster lines. (07PnnnLyyyyy) • Parallel Port • If an error occurs, the printer will print the error number and the printer’s indicator(s) LED will indicate an error condition. See the individual printer’s user manual for details. • Mobile Printers Only (TR220) • Additionally enables command error reporting via printer’s status indicator. The indicator is turned off by default for this printer only. Note • The printer’s default setting is disabled error reporting. If enabled, use the UN command to disable error reporting. Syntax UT Parameters There are no parameters for this format. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 159 160 EPL Commands U% U% Host Prompts/Motor Temperature Description This command will cause the printer to send to the host the motor temperature status through the mobile printer’s serial port. This command applies to Mobile Printers Only (TR 220). The printer will send motor temperature in 2ºC increments to the host via the serial port. The printer uses the data format of NNdeg C, where NN equals the motor temperature. Range Reported (Degrees Celsius): 24NN60 Syntax U% Parameters There are no parameters for this format. Example • In this example, the command is sent to the printer and the printer responds with a motor temperature of 24 deg C. U%↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands U$ U$ Host Prompts/Battery Status Description This command will cause the printer to send to the host the battery charge status. This command applies to EPL Mobile Printers Only (TR 220). The printer will send information about battery charge status in increments of 10 percent. The printer uses the data format of VccNNN%, where NNN represents the battery’s charge level. Note • EPL Mobile printers suspend all new printing operations, including printer to host communication, until the battery charge level is greater than 10%. Print jobs or forms (single label or batch operations) will continue processing until finished. The mobile printer will accept new commands and print after the battey charge is greater than 10%. Syntax U$ Parameters There are no parameters for this format. Example • In this example, the command is sent to the printer and the printer responds with Vcc90%. U$↵ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 161 162 EPL Commands V V Define Variable Description Use this command to define variable data for the text and bar code data fields in stored forms. Variable data can be combined with fixed data or other data types (counter, date, etc..) in text or bar code data fields. Use this command in forms that require unique data on each label. When initializing variables: • They must be defined in order (e.g. V00 first, V01 second...) • They must be the next entries after the FS"FORMNAME" command. • They must be located before any counter variables. • Variables must not contain the NULL character (0 dec.;00 hex.). The NULL character is an illegal text character. To print the contents of the variable, the variable number is referenced in the “DATA” field of the A (ASCII text) or B (Bar Code) commands. The field justification parameter effects the way the variable will be printed. When L of R are selected, the variable value will be printed left or right justified in an area with a width defined by p2 parameter. Syntax Vp1,p2,p3,”[-]PROMPT” Parameters This table identifies the parameters for this format: 14245L-001 Rev. A Parameters Details p1 = Variable number Variable (reference) numbers are sequential and must be input into a form in ascending order. Accepted Values: 00 to 99 p2 = Maximum number of characters This is the maximum number of characters allowed in the variable field. Accepted Values: 1 to 99 p3 = Field Justification Accepted Values: L = Left R = Right C = Center N = No Justification Note • Right and center justification does not apply to soft fonts. EPL Programming Guide 5/30/07 EPL Commands V Parameters Details PROMPT = ASCII text field An ASCII text field that will be transmitted to the host (via the serial interface) each time this command is executed. Use the prompt to ask for a value to be entered for the variable. [-] = KDU Options Having the first character of the prompt a single minus sign will cause the prompt to display only once after form retrieval. The KDU allows a maximum of 40 characters for entry into a variable data field and display. Accepted Values: 1 to 40 for KDU Range (p2), but not to exceed a total of 1500 bytes for all variables. Example • V00,15,N,"Enter Product Name:"↵ Note • The maximum amount of data stored as variable data, including counter variables and data reference overhead can not exceed 1500 bytes. KDU Support: Internally stored variable data fields are reset after cycling printer power or sending a reset command or pressing the Cancel. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 163 164 EPL Commands W W Windows Mode Description This command is used to disable/re-enable the Windows command mode. When enabled, the printer will accept Windows mode escape sequences to print data. When disabled, escape sequences will be ignored. The Windows mode escape sequences are only used by the optional Windows printer driver. When working with a main frame or other non-Windows host, this mode can be disabled to prevent erratic operation. Syntax Wp1 Parameters This table identifies the parameters for this format: 14245L-001 Rev. A Parameters Details p1 = Windows Mode Enabled Accepted Values: Y = enabled N = disabled Default Value: N (disabled) EPL Programming Guide 5/30/07 EPL Commands xa xa AutoSense Description This command is used to have the printer detect the label and gap length and set the sensor levels. This command will not enter into the Dump mode or print the printer configuration label. Syntax xa Parameters There are no parameters for this format. Example • In this example, the printer will feed labels and measure the labels to set the Q values (label & gap length) and the sensor levels. The printer is at Top of Form (TOF) and ready to print. xa↵ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 165 166 EPL Commands X X Box Draw Description Use this command to draw a box shape. Syntax Xp1,p2,p3,p4,p5 Parameters This table identifies the parameters for this format: Parameters Details p1 = Horizontal start position Horizontal start position (X) in dots. p2 = Vertical start position Vertical start position (Y) in dots. p3 = Line thickness Line thickness in dots. p4 = Horizontal end position Horizontal end position (X) in dots. p5 = Vertical end position Vertical end position (Y) in dots. Example • This example will produce the results shown below. N↵ X50,200,5,400,20↵ X200,50,10,20,400↵ P1↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands Y Y Serial Port Setup Description Use this command to establish the serial port communication parameters. After receiving this command, the printer will automatically reset, enabling the new rate. To send commands and data to the printer, the host’s serial port parameters must match the printer’s serial port parameters. Verify the printer’s configuration settings with the AutoSense/Dump Mode Printout, see the printer’s user manual for details. The printer’s default serial port parameters are: 9600 baud,No Parity, 8Data Bits, 1 Stop Bit Change the printer’s serial port parameters with the Y command after communication has been established with the host. The host parameters must then be changed to resume communication. Syntax Yp1,p2,p3,p4 Parameters This table identifies the parameters for this format: Parameters Details p1 = Baud rate p1 Description 38 38,400 baud (38K) 19 19,200 baud 96 9,600 baud 48 4,800 baud 24 2,400 baud 12 1,200 baud p2 = Parity Accepted Values: O = Odd parity E = Even parity N = No parity p3 = # Data bits Accepted Values: 7 = Seven data bits 8 = Eight data bits p4 = # Stop bits Accepted Values: 1 = One stop bit 2 = Two stop bits Example • This example sets 19,200 baud, odd parity, 7 data bits and 1 stop bit. Y19,O,7,1↵ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 167 168 EPL Commands Z Z Print Direction Description Use this command to select the print orientation. Syntax Zp1 Parameters This table identifies the parameters for this format: Parameters Details p1 = Print orientation Accepted Values: T = Printing from top of image buffer. B = Printing from bottom of image buffer. Default Value: T Note • The top of the image buffer prints first and is viewed by the operator as printing upside down. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands Z Example • This example will produce the results shown below. N↵ ZT↵ GG10,10,"WORLD"↵ A10,200,0,3,1,1,N,"This Graphic Was Printed With Orientation Set To ZT"↵ P1↵ N↵ ZB↵ GG10,10,"WORLD"↵ A10,200,0,3,1,1,N,"This Graphic Was Printed With Orientation Set To ZB"↵ Print Direction P1↵ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 169 170 EPL Commands ? ? Download Variables Description This command signals the printer to “fill-in” variable or counter “prompt” data field. The host system can send data representing variables and/or counters to the printer after a stored form containing variables and/or counters has been retrieved. Syntax ? DATA The amount of data following the question mark line must match exactly the order and total number of variables and/or counters for that specific form. Data must be entered, as follows: • Each DATA line represents a variable or counter data field fill-in. • Variables in ascending order (e.g. V00 first, V01 second...) • Counters in ascending order following Variables (e.g. C0 first, C1 second...) Parameters There are no parameters for this format. Example • FK"form1"↵ :delete form “form1" FS"form1"↵ :begins the form store V00,15,N,"Enter Part Name:"↵ V01,5,N,"Enter Quantity:"↵ A50,10,0,3,1,1,N,V00↵ A50,400,0,3,1,1,N,"Quantity: “V01↵ FE↵ :ends form store sequence FR"form1"↵ :retrieve for “form1" ?↵ :variables follow Screws↵ :first variable 235↵ :second variable P1↵ :print one label 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands ^@ ^@ Reset Printer Description This command is used to reset the printer. Syntax ^@ where ^ is 94 decimal This command emulates Power Off and then Power On; thus reinitializing the printer. • The reset command is unavailable during the operation of storing PCX graphics, soft fonts or while the printer is in dump mode. • The reset command cannot be used in a stored form. • The reset command can be sent to the printer during all other printing operations. • The printer will ignore all commands sent while the reset command is executing, up to 2 seconds. Parameters There are no parameters for this format. Example • This example causes the printer to reset. ^@↵ 5/30/07 EPL Programming Guide 14245L-001 Rev. A 171 172 EPL Commands ^default ^default Set Printer to Factory Defaults Description Use this command to return the printer to its default configuration. The ^default command resets the density, speed, sensors, image buffer parameters, character code page (including re-mapped characters), options, feed button behaviors, gap mode media sensing, serial interface configuration, error reporting and line mode configuration defaults. This command is intended for troubleshooting and by service organizations. Do not use this command in regular programming! Do not use this command to initialize the printer! This overwrites all stored parameters. The programmer should always minimize writing to the nonvolatile 'flash' printer memory. Supported by firmware versions 4.30 and above. Syntax ^default Parameters There are no parameters for this format. 14245L-001 Rev. A EPL Programming Guide 5/30/07 EPL Commands ^ee ^ee Error Report - Immediate Description Use this command to get printer errors and status reports immediately. The ^ee command must be sent via the USB and RS-232 serial interface. Mobile printers, such as the TR 220, ignore this command. The printer will report 4 bytes back to host in the following format: XX XX = Error/Status code = Carriage Return (ASCII 13 dec.) = Line Feed (ASCII 10 dec.) Syntax ^ee Parameters There are no parameters for this format. Code Error/Status Description 00 No Error 01 Syntax Error 02 Object Exceeded Label Border 03 Bar Code Data Length Error (e.g.: EAN-13 is a 12 or 1 digit only) 04 Insufficient Memory to Store Data 05 Memory Configuration Error 06 RS-232 Interface Error 07 Paper or Ribbon Empty 08 Duplicate Name: Form, Graphic or Soft Font 09 Name Not Found: Form, Graphic or Soft Font 10 Not in Data Entry Mode (See ? Command) 11 Printhead Up (Open) 12 Pause Mode or Paused in Peel Mode 50 Printer Busy - Processing Print Job 80* Undefined 81* Cutter Jammed or Not Installed 82* AutoSense or Sensor Failure 83* Illegal Interrupt occurred 84* Excessive Media Feeding * Requires Intervention: Press Feed or Reset (^@ command) 5/30/07 EPL Programming Guide 14245L-001 Rev. A 173 174 EPL Commands ; ; Code Comment Line Description This command signals the printer to ignore the following data. All data between the line initiating semicolon character (;) and the next line feed (LF) character (which terminates all command lines) will be ignored. Supported by firmware versions 4.30 and above. Syntax ; Comment Data Example • The phrase “This is used for xxxXXX” is ignored by the printer. ; This is used for xxxXXX↵ 14245L-001 Rev. A EPL Programming Guide 5/30/07 4 SGD Printer Setting Commands This chapter provides a high-level overview of printer setting Set / Get / Do (SGD) commands. SGD commands are available in printers with firmware versions E53.15.x or later. Important • These are important points to note when using EPL, ZPL, and SGD commands: • SGD commands are case-sensitive. • EPL, ZPL, and SGD commands should be sent to the printer as separate files. • Certain settings can be controlled by EPL, ZPL, and SGD. Configuration changes made in EPL or ZPL can affect configuration changes made in SGD. • Changes made with one command type (EPL, ZPL, and SGD) will affect the data returned to the host in response to EPL, ZPL, and getvar commands. The command type (EPL, ZPL, or SGD) that was sent last determines the current setting. • Some RF cards do not support all of the SGD commands. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 176 SGD Printer Setting Commands Overview Overview This section describes how and why to use the Set / Get / Do (SGD) commands. It also provides an example of a typical command structure. Note • SGD commands must be terminated by a carriage return or a space and line feed. SGD commands are commands that allow you to configure all printers with firmware versions E53.15.x or later. The printer performs the specified function immediately after receiving the command. The commands are: • setvar • getvar • do setvar Command Setvar commands: • are used to configure printer settings to specific values by setting them in the printer • must be terminated by a space character or a CR/ LF (0x0D, 0x0A) Important • The setvar command and attributes must be specified in lower case. getvar Command Getvar commands: • are used to get the current value of the printer settings • must be terminated by a space character or CR/LF (0x0D, 0x0A) The printer responds with the printer setting of “?” if: • the printer setting does not exist (usually due to incorrect spelling of the printer setting) • it has not been configured yet Important • The printer settings and attributes must be specified in lower case. 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Printer Setting Commands Overview do Command Do commands: • are used to instruct the printer to perform predefined actions • must be terminated by a space character or a CR/LF (0x0D, 0x0A) Some Do commands require additional settings which must be enclosed in double quotes. Important • The values must be specified in lower case. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 177 178 SGD Printer Setting Commands Command Structure Command Structure It is important to understand the structure of the command and its components. A command structure illustration is provided for each command in this guide. Example • This is an example of a command structure illustration: ! U1 setvar "ip.addr" "value" 1 1 2 3 2 3 Command—always preceded with an exclamation point (!) and must be specified in lower case. A space resides between the !and U1 and between U1 and the command (setvar or getvar). Attribute—always in double quotes and must be specified in lower case. Chosen value—always in double quotes. Only applicable for setvar and do. This command must be terminated by a space character or a CR/ LF (0x0D, 0x0A). Note • Some RF cards do not support all of the SGD commands. How to Send Multiple SGD Commands For any getvar, setvar, or do command, if you issue the syntax without the "1" and use the END command followed by a space, multiple SGD commands are sent simultaneously. Example • This syntax shows how you can send multiple getvar commands: 1 2 ! U getvar "ip.telnet.enable" getvar "ip.dhcp.enable" getvar "ip.dhcp.cid_prefix" 3 1 2 3 14245L-001 Rev. A END The command portion of the string does not use the "1" after the "! U". Commands issued after the first command do not require the "! U". The string of commands is terminated by the word "END" with a space after the word, and by a carriage return/ line feed. EPL Programming Guide 5/30/07 SGD Printer Settings appl.bootblock appl.bootblock Description This command refers to the bootblock version. On the configuration label, the bootblock number is identified as the hardware ID. This command is only supported on Zebra ZM400/ZM600™ printers. Type getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command returns the bootblock version number that appears on the configuration label . Format: ! U1 getvar "appl.bootblock" Example • In this example, the getvar returns the bootblock version number. ! U1 getvar "appl.bootblock" 5/30/07 EPL Programming Guide 14245L-001 Rev. A 179 180 SGD Printer Settings appl.name appl.name Description This command refers to the printer’s firmware version. This command is only supported on Zebra ZM400/ZM600™ printers. Type getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command returns the printer’s firmware version. Format: ! U1 getvar "appl.name" Example • In this example, the getvar returns the printer’s firmware version. ! U1 getvar "appl.name" 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Printer Settings device.languages device.languages Description This command identifies the programming language that the printer is currently using. This command is only supported on Zebra ZM400/ZM600™ printers. Type getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command retrieves the programming language that the printer is currently using. Table 3 shows the possible response values. Format: ! U1 getvar "device.languages" Example • In this example, the getvar result is the current programming language that the printer is using. ! U1 getvar "device.languages" Table 3 • Programming Languages ZPL (Zebra Programming Language) EPL (Eltron Programming Language) 5/30/07 EPL Programming Guide 14245L-001 Rev. A 181 182 SGD Printer Settings ip.active_network ip.active_network Description This command displays if the printer is actively connected to wireless, external wired, or internal wired. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with what the printer is currently connected to internal wired, wireless, external wired, or unknown. Table 4 provides details on the potential return values. Format: ! U1 getvar "ip.active_network" Example • In this example, the getvar will return the current active network the printer is connected to. ! U1 getvar "ip.active_network" Table 4 • Printer Responses Return Values Details “internal wired” This is the return value when an internal wired device is detected. “wireless” This is the return value when a wireless device is detected. “external wired” This is the return value when an external wired device is detected. “unknown” This is the return value: • if the printer has not established a network connection on any of the devices • if you don't have any of the network devices plugged in • if the printer is trying to establish a connection (for example, when wireless is going through the association process) 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Printer Settings ip.ftp.enable ip.ftp.enable Description This printer setting refers to the FTP protocol setting. This command tells the printer to turn FTP on or off. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the FTP status. Format: ! U1 getvar "ip.ftp.enable" setvar This command instructs the printer to turn FTP on or off. Format: ! U1 setvar "ip.ftp.enable" "value" Values: "off" = disables FTP "on" = enables FTP Default: "on" Example • This setvar example shows the FTP status set to "on". ! U1 setvar "ip.ftp.enable" "on" When the setvar value is set to "on", the getvar result is that the FTP status is "on". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 183 184 SGD Printer Settings ip.http.enable ip.http.enable Description This printer setting refers to the HTTP protocol/web server setting. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the HTTP status. Format: ! U1 getvar "ip.http.enable" setvar This command instructs the printer to change HTTP to on or off. Format: ! U1 setvar "ip.http.enable" "value" Values: "off" = disables HTTP protocol "on" = enables HTTP protocol Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "ip.http.enable" "on" When the setvar value is set to "on", the getvar result is "on". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Printer Settings ip.lpd.enable ip.lpd.enable Description This printer setting refers to the LPD (Line Printer Daemon) protocol setting. Type getvar; setvar Important • LPD communications from the host should be directed to port 515. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the LPD status. Format: ! U1 getvar "ip.lpd.enable" setvar This command instructs the printer to turn LPD on or off. Format: ! U1 setvar "ip.lpd.enable" "value" Values: "off" = disables LPD protocol "on" = enables LPD protocol Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "ip.lpd.enable" "on" When the setvar value is set to "on", the getvar result is "on". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 185 186 SGD Printer Settings ip.pop3.enable ip.pop3.enable Description This printer setting determines if the printer queries a POP3 mailbox for mail. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the POP3 status. Format: ! U1 getvar "ip.pop3.enable" setvar This command instructs the printer to turn POP3 on or off. Format: ! U1 setvar "ip.pop3.enable" "value" Values: "off" = disables POP3 "on" = enables POP3 Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "ip.pop3.enable" "on" When the setvar value is set to "on", the getvar result is "on". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Printer Settings ip.pop3.password ip.pop3.password Description This printer setting refers to the POP3 mailbox password. This only applies if "ip.pop3.enable" is set to on. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the POP3 password. Format: ! U1 getvar "ip.pop3.password" For protection a single "*" prints. setvar This command instructs the printer to change the POP3 password. Format: ! U1 setvar "ip.pop3.password" "value" Values: A maximum of 20 alphanumeric characters Default: " " Example • This setvar example shows the value set to "password". ! U1 setvar "ip.pop3.password" "password" When the setvar value is set to "password", the getvar result is "*". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 187 188 SGD Printer Settings ip.pop3.poll ip.pop3.poll Description This printer setting refers to how frequent (in seconds) the printer queries a POP3 mailbox for new mail. This only applies if the "ip.pop3.enable" is set to on. Type getvar; setvar Note • A poll value of less then thirty seconds is not recommended. The printer is unresponsive for several seconds when polling for email depending on data transfer time from the server to the printer. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the POP3 poll frequency (in seconds). Format: ! U1 getvar "ip.pop3.poll" setvar This command instructs the printer to change the POP3 poll interval. A value of "0" causes the printer to only query the POP3 mailbox one time, on printer power up, or following a network reset. Format: ! U1 setvar "ip.pop3.poll" "value" Values: "0" through "65535" Default: "0" Example • This setvar example shows the value set to "0". ! U1 setvar "ip.pop3.poll" "0" When the setvar value is set to "0", the getvar result is "0". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Printer Settings ip.pop3.server_addr ip.pop3.server_addr Description This printer setting refers to the POP3 server IP address that the printer contacts when checking for new mail. This only applies if "ip.pop3.enable" is set to on. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the POP3 server address. Format: ! U1 getvar "ip.pop3.server_addr" setvar This command instructs the printer to change the POP3 server address. Format: ! U1 setvar "ip.pop3.server_addr" "value" Values: Any valid POP3 server address Default: "0.0.0.0" Example • This setvar example shows the value set to "10.3.5.10". ! U1 setvar "ip.pop3.server_addr" "10.3.5.10" When the setvar value is set to "10.3.5.10", the getvar result is "10.3.5.10". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 189 190 SGD Printer Settings ip.pop3.username ip.pop3.username Description This printer setting refers to the POP3 user name. This only applies if the "ip.pop3.enable" is set to on. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the POP3 user name. Format: ! U1 getvar "ip.pop3.username" setvar This command instructs the printer to change the POP3 user name. Format: ! U1 setvar "ip.pop3.username" "value" Values: A maximum of 20 alphanumeric characters Default: " " Example • This setvar example shows the value set to "user". ! U1 setvar "ip.pop3.username" "user" When the setvar value is set to "user", the getvar result is "user". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Printer Settings ip.primary_network ip.primary_network Description This command allows you to set the primary network to either wired or wireless. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the name of the current primary network device. Format: ! U1 getvar "ip.primary_network" setvar This command instructs the printer to set the current network device. Format: ! U1 setvar "ip.primary_network" "value" Values: 1 = wired 2 = wireless Default: "wired" Example • This setvar example shows the value set to "wired". ! U1 setvar "ip.primary_network" "wired" What the setvar value is set to is the getvar result. In this example, the getvar result is "wired". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 191 192 SGD Printer Settings ip.smtp.domain ip.smtp.domain Description This printer setting refers to the domain name used by the printer in sending email with respect to the SMTP server. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to return the SMTP domain name. Format: ! U1 getvar "ip.smtp.domain" setvar This command instructs the printer to change the SMTP domain name. Format: ! U1 setvar "ip.smtp.domain" "value" Values: A maximum of 24 alphanumeric characters Default: "ZBRPrintServer" Example • This setvar example shows the value set to "ZBRPrintServer.com". ! U1 setvar "ip.smtp.domain" "ZBRPrintServer.com" When the setvar value is set to "ZBRPrintServer.com", the getvar result is "ZBRPrintServer.com". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Printer Settings ip.smtp.enable ip.smtp.enable Description This printer setting refers to the SMTP protocol. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to return the SMTP status. Format: ! U1 getvar "ip.smtp.enable" setvar This command instructs the printer to turn SMTP on or off. Format: ! U1 setvar "ip.smtp.enable" "value" Values: "off" = disables SMTP "on" = enables SMTP Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "ip.smtp.enable" "on" When the setvar value is set to "on", the getvar result is "on". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 193 194 SGD Printer Settings ip.smtp.server_addr ip.smtp.server_addr Description This printer setting refers to the IP address of the SMTP server used for sending email. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the current SMTP server address. Format: ! U1 getvar "ip.smtp.server_addr" setvar This command instructs the printer to change the SMTP server address. Format: ! U1 setvar "ip.smtp.server_addr" "value" Values: Any valid IP address. Default: 0.0.0.0 Example • This setvar example shows the value set to 10.10.10.10. ! U1 setvar "ip.smtp.server_addr" "10.10.10.10" When the setvar value is set to "10.10.10.10", the getvar result is "10.10.10.10". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Printer Settings ip.snmp.get_community_name ip.snmp.get_community_name Description This printer setting is used when making SNMP queries. The SNMP client must supply the get community name that matches the printer’s get community name in order to query any SNMP data. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to get the SNMP get community name string. Format: ! U1 getvar "ip.snmp.get_community_name" For protection a single "*" prints. setvar This command instructs the printer to set the SNMP get community name string. Format: ! U1 setvar "ip.snmp.get_community_name" "value" Values: A maximum of 19 alphanumeric characters. Default: "public" Example • This setvar example shows the value set to "public". ! U1 setvar "ip.snmp.get_community_name" "public" When the setvar value is set to "public", the getvar result is "*". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 195 196 SGD Printer Settings ip.snmp.set_community_name ip.snmp.set_community_name Description This printer setting is used when changing SNMP data remotely. To alter any SNMP data, the SNMP client must supply the set community name that matches the printer’s set community name. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to return the printer’s SNMP set community name string. Format: ! U1 getvar "ip.snmp.set_community_name" For protection a single "*" returns. setvar This command instructs the printer to set the SNMP set community name string. Format: ! U1 setvar "ip.snmp.set_community_name" "value" Values: A maximum of 19 alphanumeric characters Default: "public" Example • This setvar example shows the value set to "public". ! U1 setvar "ip.snmp.set_community_name" "public" When the setvar value is set to "public", the getvar result is "*". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Printer Settings ip.telnet.enable ip.telnet.enable Description This printer setting refers to the TELNET (port 23) protocol. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the TELNET status. Format: ! U1 getvar "ip.telnet.enable" setvar This command instructs the printer to turn TELNET on or off. Format: ! U1 setvar "ip.telnet.enable" "value" Values: "off" = disables telnet protocol "on" = enables telnet protocol Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "ip.telnet.enable" "on" When the setvar value is set to "on", the getvar result is "on". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 197 198 SGD Printer Settings ip.snmp.enable ip.snmp.enable Description This printer setting refers to the SNMP protocol. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the SNMP status. Format: ! U1 getvar "ip.snmp.enable" setvar This command instructs the printer to enable or disable the SNMP protocol. Format: ! U1 setvar "ip.snmp.enable" "value" Values: "on" = enable the SNMP protocol "off" = disable the SNMP protocol Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "ip.snmp.enable" "on" When the setvar value is set to "on", the getvar result is "on". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Printer Settings ip.tcp.enable ip.tcp.enable Description This printer setting refers to the TCP socket protocol. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the TCP status. Format: ! U1 getvar "ip.tcp.enable" setvar This command instructs the printer to turn the TCP on or off. Format: ! U1 setvar "ip.tcp.enable" "value" Values: "off" = disables TCP protocol "on" = enables TCP protocol Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "ip.tcp.enable" "on" When the setvar value is set to "on", the getvar result is "on". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 199 200 SGD Printer Settings ip.udp.enable ip.udp.enable Description This printer setting refers to the UDP socket protocol. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the UDP status. Format: ! U1 getvar "ip.udp.enable" setvar This command instructs the printer to turn UDP on or off. Format: ! U1 setvar "ip.udp.enable" "value" Values: "off" = disables UDP protocol "on" = enables UDP protocol Default: "off" Example • This setvar example shows the value set to "on". ! U1 setvar "ip.udp.enable" "on" When the setvar value is set to "on", the getvar result is "on". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Printer Settings media.printmode media.printmode Description This printer setting determines the action the printer takes after a label or group of labels has printed. This command is only supported on Zebra ZM400/ZM600™ printers. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the the currently set media print mode. Format: ! U1 getvar "media.printmode" setvar This command instructs the printer to change the media print mode. Format: ! U1 setvar "media.printmode" "value" Values: tear off = "T" peel off = "P" rewind = "R" applicator = "A" cutter = "C" delayed cutter = "D" reserved = "L" * reserved = "U" * * These values are only supported on the Zebra ZM400/ZM600™ printer. Example • This setvar example shows the value set to "T". ! U1 setvar "media.printmode" "T" What the setvar value is set to is the getvar result. In this example, the getvar result is "tear off". For more details on how each setvar value relates to the getvar responses, see Table 5, Setvar / Getvar Relation on page 202. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 201 202 SGD Printer Settings media.printmode Table 5 • Setvar / Getvar Relation If the setvar is set to … Then the getvar response and front panel display is … "T" TEAR OFF "P" PEEL OFF "R" REWIND "A" APPLICATOR "C" CUTTER "D" DELAYED CUT "L" RESERVED "U" RESERVED 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Printer Settings odometer.headclean odometer.headclean Description This printer setting refers to the head clean odometer count. This counter tracks how many inches and centimeters have passed through the printer since the head was last cleaned. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to retrieve the values for the head clean counter. Format: ! U1 getvar "odometer.headclean" setvar This command instructs the printer to reset the head clean counter. Format: ! U1 setvar "odometer.headclean" "value" Values: "0" = reset the head clean counter Default: must be an accepted value or it is ignored Example • This example shows how to get the odometer head clean, how to reset it, and how to confirm the settings changed. 1. To see the current settings, type: ! U1 getvar "odometer.headclean" Something similar to this is shown: "1489 INCHES, 3784 CENTIMETERS" 2. To reset the these values to 0, type: ! U1 setvar "odometer.headclean" "0" 3. To confirm this settings were reset, type: ! U1 getvar "odometer.headclean" If the resetting was successful, this is shown: "0 INCHES, 0 CENTIMETERS" 5/30/07 EPL Programming Guide 14245L-001 Rev. A 203 204 SGD Printer Settings odometer.headnew odometer.headnew Description This printer setting refers to the head replaced odometer count. This counter tracks how many inches and centimeter passed through the printer since the head was last replaced. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to retrieve the values for the head new counter. Format: ! U1 getvar "odometer.headnew" setvar This command instructs the printer to reset the head new counter. Format: ! U1 setvar "odometer.headnew" "value" Values: "0" = resets the head new counter Default: must be an accepted value or it is ignored Example • This example shows how to get the odometer head new, how to reset it, and how to confirm the settings changed: 1. To see the current settings, type: ! U1 getvar "odometer.headnew" Something similar to this is shown: "1489 INCHES, 3784 CENTIMETERS" 2. To reset the these values to 0, type: ! U1 setvar "odometer.headnew" "0" 3. To confirm this settings were reset, type: ! U1 getvar "odometer.headnew" If the resetting was successful, this is shown: "0 INCHES, 0 CENTIMETERS 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Printer Settings odometer.label_dot_length odometer.label_dot_length Description This command returns the length of the last label printed or fed (in dots). This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command returns the length of the last label printed or fed (in dots). Format: ! U1 getvar "odometer.label_dot_length" Example • This is an example of how to reset the length using the ^LL command and how to use the getvar to confirm the change. For the ^LL command to work the printer must be in continuous mode. 1. To change the odometer label dot length, type: ^XA ^LL500 ^XZ 2. To get the current odometer label dot length, type: ! U1 getvar "odometer.label_dot_length" Something similar to this is shown: "500" 5/30/07 EPL Programming Guide 14245L-001 Rev. A 205 206 SGD Printer Settings odometer.media_marker_count1 odometer.media_marker_count1 Description This printer setting refers to the value of the first (count1) user resettable counter. The user resettable counters track how much media has passed through the printer in both inches or centimeters. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Note • Here are some reference links for this command: • For details on the command structure of SGD commands, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to return the current value of the first (count1) user resettable counter in both inches and centimeters. Format: ! U1 getvar "odometer.media_marker_count1" setvar This command instructs the printer to reset the first user resettable counter. Format: ! U1 setvar "odometer.media_marker_count1" "value" Values: "0" = reset the counter Default: must be an accepted value or it is ignored Example • This example shows how to get the first user resettable counter, how to reset it, and how to confirm the settings have changed: 1. To see the current settings, type: ! U1 getvar "odometer.media_marker_count1" Something similar to this is shown: "8516 INCHES, 21632 CENTIMETERS" 2. To reset the these values to 0, type: ! U1 setvar "odometer.media_marker_count1" "0" 3. To confirm these settings were reset, type: ! U1 getvar "odometer.media_marker_count1" If the resetting was successful, this is shown: "0 INCHES, 0 CENTIMETERS" 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Printer Settings odometer.media_marker_count2 odometer.media_marker_count2 Description This printer setting refers to the value of the second (count2) user resettable counter. The user resettable counters track how much media has passed through the printer in both inches or centimeters. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to return the current value of the second (count2) user resettable counter in both inches and centimeters. Format: ! U1 getvar "odometer.media_marker_count2" setvar This command instructs the printer to reset the second user resettable counter. Format: ! U1 setvar "odometer.media_marker_count2" "value" Values: "0" = reset the counter Default: must be an accepted value or it is ignored Example • This example shows how to get the second user resettable counter, how to reset it, and how to confirm the settings have changed: 1. To see the current settings, type: ! U1 getvar "odometer.media_marker_count2" Something similar to this is shown: "8516 INCHES, 21632 CENTIMETERS" 2. To reset the these values to 0, type: ! U1 setvar "odometer.media_marker_count2" "0" 3. To confirm these settings were reset, type: ! U1 getvar "odometer.media_marker_count2" If the resetting was successful, this is shown: "0 INCHES, 0 CENTIMETERS" 5/30/07 EPL Programming Guide 14245L-001 Rev. A 207 208 SGD Printer Settings odometer.total_print_length odometer.total_print_length Description This command tracks the total length of media that printed over the life of the printer. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 178. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command returns the value of the total length of media that printed over the life of the printer. Format: ! U1 getvar "odometer.total_print_length" Example • This example shows how to get the total length of media that printed over the life of the printer. 1. To get the total length of media that has printed to date, type: ! U1 getvar "odometer.total_print_length" Something similar to this is shown: "8560 INCHES, 21744 CENTIMETERS" 14245L-001 Rev. A EPL Programming Guide 5/30/07 5 SGD Wired Commands This chapter provides a high-level overview of the wired Set / Get / Do (SGD) commands. The commands in this chapter are only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. Important • These are important points to note when using EPL, ZPL, and SGD commands: • SGD commands are case-sensitive. • EPL, ZPL, and SGD commands should be sent to the printer as separate files. • Certain settings can be controlled by EPL, ZPL, and SGD. Configuration changes made in EPL or ZPL can affect configuration changes made in SGD. • Changes made with one command type (EPL, ZPL, and SGD) will affect the data returned to the host in response to EPL, ZPL, and getvar commands. The command type (EPL, ZPL, or SGD) that was sent last determines the current setting. • Some RF cards do not support all of the SGD commands. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 210 SGD Wired Commands Overview Overview This section describes how and why to use the Set / Get / Do (SGD) commands. It also provides an example of a typical command structure. Note • SGD commands must be terminated by a carriage return or a space and line feed. SGD commands are commands that allow you to configure all printers with firmware versions E53.15.x or later. The printer performs the specified function immediately after receiving the command. The commands are: • setvar • getvar • do setvar Command Setvar commands: • are used to configure printer settings to specific values by setting them in the printer • must be terminated by a space character or a CR/ LF (0x0D, 0x0A) Important • The setvar command and attributes must be specified in lower case. getvar Command Getvar commands: • are used to get the current value of the printer settings • must be terminated by a space character or CR/LF (0x0D, 0x0A) The printer responds with the printer setting of “?” if: • the printer setting does not exist (usually due to incorrect spelling of the printer setting) • it has not been configured yet Important • The printer settings and attributes must be specified in lower case. 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wired Commands Overview do Command Do commands: • are used to instruct the printer to perform predefined actions • must be terminated by a space character or a CR/LF (0x0D, 0x0A) Some Do commands require additional settings which must be enclosed in double quotes. Important • The values must be specified in lower case. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 211 212 SGD Wired Commands Command Structure Command Structure It is important to understand the structure of the command and its components. A command structure illustration is provided for each command in this guide. Example • This is an example of a command structure illustration: ! U1 setvar "ip.addr" "value" 1 1 2 3 2 3 Command—always preceded with an exclamation point (!) and must be specified in lower case. A space resides between the !and U1 and between U1 and the command (setvar or getvar). Attribute—always in double quotes and must be specified in lower case. Chosen value—always in double quotes. Only applicable for setvar and do. This command must be terminated by a space character or a CR/ LF (0x0D, 0x0A). Note • Some RF cards do not support all of the SGD commands. How to Send Multiple SGD Commands For any getvar, setvar, or do command, if you issue the syntax without the "1" and use the END command followed by a space, multiple SGD commands are sent simultaneously. Example • This syntax shows how you can send multiple getvar commands: 1 2 ! U getvar "ip.telnet.enable" getvar "ip.dhcp.enable" getvar "ip.dhcp.cid_prefix" 3 1 2 3 14245L-001 Rev. A END The command portion of the string does not use the "1" after the "! U". Commands issued after the first command do not require the "! U". The string of commands is terminated by the word "END" with a space after the word, and by a carriage return/ line feed. EPL Programming Guide 5/30/07 SGD Wired Commands external_wired.ip.addr external_wired.ip.addr Description This command allows you to get or set the external wired print servers’s IP address. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This feature works with the ZebraNet 10/100 External Print Server, firmware version 1.1.5. Type getvar; setvar Important • For a set IP address to take affect, the IP protocol must be set to permanent and the print server must be reset. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with its current external wired print server IP address. Format: ! U1 getvar "external_wired.ip.addr" setvar This command instructs the printer to change its current external wired print server IP address upon powering the printer on. Format: ! U1 setvar "external_wired.ip.addr" "value" Values: any valid IP address Default: "0.0.0.0" Note • The setvar value of this command can be affected by the external_wired.ip.dhcp.enable command. Example • This setvar example shows the value set to "10.14.4.235". ! U1 setvar "external_wired.ip.addr" "10.14.4.235" What the setvar value is set to is the getvar result. In this example, the getvar result is "10.14.4.235". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 213 214 SGD Wired Commands external_wired.ip.arp_interval external_wired.ip.arp_interval Description This print server setting allows you to specify the ARP (Address Resolution Protocol) interval or the ARP cache time out for the external wired print server. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the ARP interval or the ARP cache time out value for the external wired print server. Format: ! U1 getvar "external_wired.ip.arp_interval" setvar This command instructs the printer to change the ARP interval or the ARP cache time out for the external wired print server. Format: ! U1 setvar "external_wired.ip.arp_interval" "value" Values: 0 - 30 Default: "0" Example • This setvar example shows the value set to "0". ! U1 setvar "external_wired.ip.arp_interval" "0" What the setvar value is set to is the getvar result. In this example, the getvar result is "0". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wired Commands external_wired.ip.default_addr.enable external_wired.ip.default_addr.enable Description This command allows you to default the external wired print server’s IP address. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. Type getvar; setvar Important • For a set IP address to take affect, the IP protocol must be set to permanent and the print server must be reset. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to show the status of the setting of external wired print server’s default IP address feature. Format: ! U1 getvar "external_wired.ip.default_addr.enable" setvar This command tells the printer to use it’s default address, if no address is provided through DHCP or BOOTP. If you do not assign an IP address after 2 minutes, the 10/100 Internal PS defaults to IP address 192.168.254.254. Format: ! U1 setvar "external_wired.ip.default_addr.enable" "value" Values: "on" = enabled "off" = disabled Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "external_wired.ip.default_addr.enable" "on" What the setvar value is set to is the getvar result. In this example, the getvar result is "on". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 215 216 SGD Wired Commands external_wired.ip.dhcp.cid_all external_wired.ip.dhcp.cid_all Description This printer setting defines the entire client identifier (DHCP option 61) if DHCP is enabled on the external print server and "external_wired.ip.dhcp.cid_type" is set to "0", or "2". The MAC address is used if the type is set to "1". This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This feature works with the ZebraNet 10/100 External Print Server, firmware version 1.1.5. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier prefix and suffix of the external wired print server. Format: ! U1 getvar "external_wired.ip.dhcp.cid_all" setvar This command instructs the printer to change the client identifier prefix and suffix of the external wired print server. The prefix gets cleared and the suffix contains the entire client identifier. Format: ! U1 setvar "external_wired.ip.dhcp.cid_all" "value" Values: A maximum length of 60 characters if the CID type is ASCII, or 120 characters if the CID type is hexadecimal. Default Value: "" Example • This setvar example shows the value set to "printer". ! U1 setvar "external_wired.ip.dhcp.cid_all" "printer" What the setvar value is set to is the getvar result. In this example, the getvar result is "printer". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wired Commands external_wired.ip.dhcp.cid_enable external_wired.ip.dhcp.cid_enable Description This command determines if DHCP (option 61) on the external wired print server is turned on or off. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This feature works with the ZebraNet 10/100 External Print Server, firmware version 1.1.5. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the status of the client identifier of the external wired print server. Format: ! U1 getvar "external_wired.ip.dhcp.cid_enable" setvar This command instructs the printer to set the status of the client identifier of the external wired print server. Format: ! U1 setvar "external_wired.ip.dhcp.cid_enable" "value" Values: "off" = client identifier is turned off "on" = client identifier is turned on Default: "off" Example • This setvar example shows the value set to "off". ! U1 setvar "external_wired.ip.dhcp.cid_enable" "off" What the setvar value is set to is the getvar result. In this example, the getvar result is "off". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 217 218 SGD Wired Commands external_wired.ip.dhcp.cid_prefix external_wired.ip.dhcp.cid_prefix Description This printer setting defines the prefix to be prepended to the DHCP client identifier (option 61) when DHCP is enabled on the external wired print server and "external_wired.ip.dhcp.cid_type" is set to "0" or "2". This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This feature works with the ZebraNet 10/100 External Print Server, firmware version 1.1.5. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier prefix of the external wired print server. Format: ! U1 getvar "external_wired.ip.dhcp.cid_prefix" setvar This command instructs the printer to change the CID prefix of the external wired print server. Format: ! U1 setvar "external_wired.ip.dhcp.cid_prefix" "value" Values: Any text string up to 10 characters if the CID type is ASCII, or 20 characters if the CID type is hexadecimal. Default Value: "" Example • This setvar example shows the value set to "PRT001". ! U1 setvar "external_wired.ip.dhcp.cid_prefix" "PRT001" What the setvar value is set to is the getvar result. In this example, the getvar result is "PRT001". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wired Commands external_wired.ip.dhcp.cid_suffix external_wired.ip.dhcp.cid_suffix Description This printer setting defines the unique suffix to be used as the client identifier (DHCP option 61) if DHCP is enabled repeated on the external wired print server and external_wired.ip.dhcp.cid_type on page 220 is set to "0" or "2", not "1". This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This feature works with the ZebraNet 10/100 External Print Server, firmware version 1.1.5. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier suffix on the external wired print server. Format: ! U1 getvar "external_wired.ip.dhcp.cid_suffix" setvar This command instructs the printer to change the client identifier suffix value. Format: ! U1 setvar "external_wired.ip.dhcp.cid_suffix" "value" Values: The maximum length of a value allowed is 60 ASCII characters when the CID type is ASCII, or 120 hexadecimal values when the CID type is hexadecimal. Default Value: "" Example • This setvar example shows setting the suffix to "printer". ! U1 setvar "external_wired.ip.dhcp.cid_suffix" "printer" What the setvar value is set to is the getvar result. In this example, the getvar result is "printer". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 219 220 SGD Wired Commands external_wired.ip.dhcp.cid_type external_wired.ip.dhcp.cid_type Description This printer setting defines the type of client identifier (DHCP option 61) that will be sent if DHCP is enabled on the external wired print server. A value of "1" means the type of "Ethernet" and the printer’s MAC address will be used. A value of "0" or "2" means the client identifier sent will be "external_wired.ip.dhcp.cid_prefix" concatenated with "external_wired.ip.dhcp.cid_suffix". This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This feature works with the ZebraNet 10/100 External Print Server, firmware version 1.1.5. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier type for the external wired print server. Format: ! U1 getvar "external_wired.ip.dhcp.cid_type" setvar This command instructs the printer to enable "synthetic" Client Identifier for the external wired print server. Format: ! U1 setvar "external_wired.ip.dhcp.cid_type" "value" Values: "0" = ASCII string "1" = wired print server’s MAC address "2" = HEX value Default Value: "1" Example • This setvar example shows the value set to "1". ! U1 setvar "external_wired.ip.dhcp.cid_type" "1" What the setvar value is set to is the getvar result. In this example, the getvar result is "1". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wired Commands external_wired.ip.gateway external_wired.ip.gateway Description This command instructs the printer to change the external wired print server’s gateway address. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. Type getvar; setvar Important • This setting refers to the gateway address. A set value is ignored if the IP protocol is not set to permanent. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the external wired printer server’s gateway address. Format: ! U1 getvar "external_wired.ip.gateway" setvar This command instructs the printer to change the external wired printer server’s gateway address. Format: ! U1 setvar "external_wired.ip.gateway" "value" Values: Any valid gateway address Default: "0.0.0.0" Example • This setvar example shows the value set to "10.3.5.1". ! U1 setvar "external_wired.ip.gateway" "10.3.5.1" When the setvar value is set to "10.3.5.1", the getvar result is "10.3.5.1". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 221 222 SGD Wired Commands external_wired.ip.netmask external_wired.ip.netmask Description This setting refers to the external wired print server’s subnet mask address. This value is ignored if the IP protocol is not set to permanent. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the external wired print server’s subnet mask. Format: ! U1 getvar "external_wired.ip.netmask" setvar This command instructs the printer to change the external wired print servers’s subnet mask. Format: ! U1 setvar "external_wired.ip.netmask" "value" Values: Any valid subnet mask. Default: "255.255.255.0" Example • This setvar example shows the value set to "255.255.255.0". ! U1 setvar "external_wired.ip.netmask" "255.255.255.0" When the setvar value is set to "255.255.255.0", the getvar result is "255.255.255.0". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wired Commands external_wired.ip.port external_wired.ip.port Description This printer setting refers to the external wired print server’s port number that the TCP print service is listening on. Normal TCP communications from the host should be directed to this port. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the external wired printer server’s TCP/UDP port number. Format: ! U1 getvar "external_wired.ip.port" setvar This command instructs the printer to set the external wired print server’s TCP/UDP port number. Format: ! U1 setvar "external_wired.ip.port" "value" Values: 1 - 65535 (excluding any ports currently used by other services, such as 21, 23, 80, and 515). Default: "9100" Example • This setvar example shows the value set to "9100". ! U1 setvar "external_wired.ip.port" "9100" When the setvar value is set to "9100", the getvar result is "9100". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 223 224 SGD Wired Commands external_wired.ip.protocol external_wired.ip.protocol Description This command configures the IP addressing method used by the external wired print server. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command returns the IP addressing method used by the external print server. Format: ! U1 getvar "external_wired.ip.protocol" setvar This command instructs the printer to configure the IP addressing method used by the external wired print server. Format: ! U1 setvar "external_wired.ip.protocol" "value" Values: "bootp" = uses the standard bootp addressing method to obtain an IP address and configuration "dhcp" = uses the standard dhcp addressing method to obtain an IP address and configuration for a server specified period of time "rarp" = uses the standard rarp addressing method to obtain an IP address "glean" = uses the IP address from a PING packet that is sent to its hardware address (unicast address) “permanent” = uses static values assigned through other commands "all" = tries all of the dynamic addressing methods, not permanent, to obtain an IP address Default: "all" Example • In this example, the setvar result is the current programming language that the printer is using. ! U1 setvar "external_wired.ip.protocol" "bootp" What the setvar value is set to is the getvar result. In this example, the getvar result is "bootp". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wired Commands external_wired.ip.timeout.enable external_wired.ip.timeout.enable Description This network setting refers to enabling the connection timeout on the external wired 10/100 print server. For this to take effect, the print server must be reset. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to return whether the timeout checking is enabled on the external wired print server. Format: ! U1 getvar "external_wired.ip.timeout.enable" setvar This command instructs the printer to enable or disable the timeout checking on the external wired print server. Format: ! U1 setvar "external_wired.ip.timeout.enable" "value" Values: "off" = turns off the connection checking "on" = turns on the connection checking Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "external_wired.ip.timeout.enable" "on" When the setvar value is set to "on", the getvar result is "on". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 225 226 SGD Wired Commands external_wired.ip.timeout.value external_wired.ip.timeout.value Description This network setting refers to the number of seconds before the connection times out for the external wired print server. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the time of the external wired print server, in seconds, before the connection times out. Format: ! U1 getvar "external_wired.ip.timeout.value" setvar This command instructs the printer to set the time of the external wired print server, in seconds, before the connection times out. Format: ! U1 setvar "external_wired.ip.timeout.value" "value" Values: "0" through "3600" Default: "300" Example • This setvar example shows the value set to "300". ! U1 setvar "external_wired.ip.timeout.value" "300" When the setvar value is set to "300", the getvar result is "300". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wired Commands external_wired.mac_addr external_wired.mac_addr Description This command retrieves the MAC address of the external wired print server. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. Type getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command instructs the printer to respond with the MAC address of the external wired print server. Format: ! U1 getvar "external_wired.mac_addr" Example • In this example, the getvar result is the MAC address of the external wired print server. ! U1 getvar "external_wired.mac_addr" 5/30/07 EPL Programming Guide 14245L-001 Rev. A 227 228 SGD Wired Commands internal_wired.ip.addr internal_wired.ip.addr Description This command allows you to get or set the internal wired print servers’s IP address. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This command is only supported on ZM400/ZM600™ printers with a ZebraNet™ 10/100 Internal Print Server. Type getvar; setvar Important • For a set IP address to take affect, the IP protocol must be set to permanent and the print server must be reset. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with its current internal wired print server IP address. Format: ! U1 getvar "internal_wired.ip.addr" setvar This command instructs the printer to change its current internal wired print server IP address upon powering the printer on. Format: ! U1 setvar "internal_wired.ip.addr" "value" Values: any valid IP address Default: "0.0.0.0" Note • The setvar value of this command can be affected by the internal_wired.ip.dhcp.enable command. Example • This setvar example shows the value set to "10.14.4.235". ! U1 setvar "internal_wired.ip.addr" "10.14.4.235" What the setvar value is set to is the getvar result. In this example, the getvar result is "10.14.4.235". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wired Commands internal_wired.ip.arp_interval internal_wired.ip.arp_interval Description This print server setting allows you to specify the ARP (Address Resolution Protocol) interval or the ARP cache time out for the internal wired print server. This command is only supported on ZM400/ZM600™ printers with a ZebraNet™ 10/100 Internal Print Server. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the ARP interval or the ARP cache time out value for the internal wired print server. Format: ! U1 getvar "internal_wired.ip.arp_interval" setvar This command instructs the printer to change the ARP interval or the ARP cache time out for the internal wired print server. Format: ! U1 setvar "internal_wired.ip.arp_interval" "value" Values: 0 - 30 Default: "0" Example • This setvar example shows the value set to "0". ! U1 setvar "internal_wired.ip.arp_interval" "0" What the setvar value is set to is the getvar result. In this example, the getvar result is "0". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 229 230 SGD Wired Commands internal_wired.ip.default_addr.enable internal_wired.ip.default_addr.enable Description This command allows you to default the internal wired print server’s IP address. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This command is only supported on ZM400/ZM600™ printers with a ZebraNet™ 10/100 Internal Print Server. Type getvar; setvar Important • For a set IP address to take affect, the IP protocol must be set to permanent and the print server must be reset. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to show the status of the setting of internal wired print server’s default IP address feature. Format: ! U1 getvar "internal_wired.ip.default_addr.enable" setvar This command tells the printer to use it’s default address, if no address is provided through DHCP or BOOTP. If you do not assign an IP address after 2 minutes, the 10/100 Internal PS defaults to IP address 192.168.254.254. Format: ! U1 setvar "internal_wired.ip.default_addr.enable" "value" Values: "on" = enabled "off" = disabled Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "internal_wired.ip.default_addr.enable" "on" What the setvar value is set to is the getvar result. In this example, the getvar result is "on". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wired Commands internal_wired.ip.dhcp.cid_all internal_wired.ip.dhcp.cid_all Description This printer setting defines the entire client identifier (DHCP option 61) if DHCP is enabled on the internal print server and "internal_wired.ip.dhcp.cid_type" is set to "0", or "2". The MAC address is used if the type is set to "1". This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This command is only supported on ZM400/ZM600™ printers with a ZebraNet™ 10/100 Internal Print Server. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier prefix and suffix of the internal wired print server. Format: ! U1 getvar "internal_wired.ip.dhcp.cid_all" setvar This command instructs the printer to change the client identifier prefix and suffix of the internal wired print server. The prefix gets cleared and the suffix contains the entire client identifer. Format: ! U1 setvar "internal_wired.ip.dhcp.cid_all" "value" Values: A maximum length of 60 characters if the CID type is ASCII, or 120 characters if the CID type is hexadecimal. Default Value: "" Example • This setvar example shows the value set to "printer". ! U1 setvar "internal_wired.ip.dhcp.cid_all" "printer" What the setvar value is set to is the getvar result. In this example, the getvar result is "printer". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 231 232 SGD Wired Commands internal_wired.ip.dhcp.cid_enable internal_wired.ip.dhcp.cid_enable Description This command determines if DHCP (option 61) is turned on or off of the internal wired print server. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This command is only supported on ZM400/ZM600™ printers with a ZebraNet™ 10/100 Internal Print Server. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the status of the client identifier of the internal wired print server. Format: ! U1 getvar "internal_wired.ip.dhcp.cid_enable" setvar This command instructs the printer to set the status of the client identifier of the internal wired print server. Format: ! U1 setvar "internal_wired.ip.dhcp.cid_enable" "value" Values: "off" = client identifier is turned off "on" = client identifier is turned on Default: "off" Example • This setvar example shows the value set to "off". ! U1 setvar "internal_wired.ip.dhcp.cid_enable" "off" What the setvar value is set to is the getvar result. In this example, the getvar result is "off". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wired Commands internal_wired.ip.dhcp.cid_prefix internal_wired.ip.dhcp.cid_prefix Description This printer setting defines the prefix to be prepended to the DHCP client identifier (option 61) when DHCP is enabled on the internal wired print server and "internal_wired.ip.dhcp.cid_type" is set to "0" or "2". This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This command is only supported on ZM400/ZM600™ printers with a ZebraNet™ 10/100 Internal Print Server. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier prefix of the internal wired print server. Format: ! U1 getvar "internal_wired.ip.dhcp.cid_prefix" setvar This command instructs the printer to change the CID prefix of the internal wired print server. Format: ! U1 setvar "internal_wired.ip.dhcp.cid_prefix" "value" Values: Any text string up to 10 characters if the CID type is ASCII, or 20 characters if the CID type is hexadecimal. Default Value: "" Example • This setvar example shows the value set to "PRT001". ! U1 setvar "internal_wired.ip.dhcp.cid_prefix" "PRT001" What the setvar value is set to is the getvar result. In this example, the getvar result is "PRT001". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 233 234 SGD Wired Commands internal_wired.ip.dhcp.cid_suffix internal_wired.ip.dhcp.cid_suffix Description This printer setting defines the unique suffix to be used as the client identifier (DHCP option 61) if DHCP is enabled on the internal wired 10/100 print server and "internal_wired.ip.dhcp.cid_type" is set to "0" or "2", not "1". This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This command is only supported on ZM400/ZM600™ printers with a ZebraNet™ 10/100 Internal Print Server. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier suffix of the internal wired 10/100 print server. Format: ! U1 getvar "internal_wired.ip.dhcp.cid_suffix" setvar This command instructs the printer to change the client identifier suffix value of the internal wired 10/100 print server. Format: ! U1 setvar "internal_wired.ip.dhcp.cid_suffix" "value" Values: The maximum length of a value allowed is 60 ASCII characters when the CID type is ASCII, or 120 hexadecimal values when the CID type is hexadecimal. Default Value: "" Example • This setvar example shows the value set to "printer". ! U1 setvar "internal_wired.ip.dhcp.cid_suffix" "printer" What the setvar value is set to is the getvar result. In this example, the getvar result is "printer". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wired Commands internal_wired.ip.dhcp.cid_type internal_wired.ip.dhcp.cid_type Description This printer setting defines the type of client identifier (DHCP option 61) that will be sent if DHCP is enabled on the internal wired print server. A value of "1" means the type of "Ethernet" and the printer’s MAC address will be used.A value of "0" or "2" means the client identifier sent will be "internal_wired.ip.dhcp.cid_prefix" concatenated with "internal_wired.ip.dhcp.cid_suffix". This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This command is only supported on ZM400/ZM600™ printers with a ZebraNet™ 10/100 Internal Print Server. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier type for the internal wired print server. Format: ! U1 getvar "internal_wired.ip.dhcp.cid_type" setvar This command instructs the printer to enable "synthetic" Client Identifier for the internal wired print server. Format: ! U1 setvar "internal_wired.ip.dhcp.cid_type" "value" Values: "0" = ASCII string "1" = wired print server’s MAC address "2" = HEX value Default Value: "1" Example • This setvar example shows the value set to "1". ! U1 setvar "internal_wired.ip.dhcp.cid_type" "1" What the setvar value is set to is the getvar result. In this example, the getvar result is "1". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 235 236 SGD Wired Commands internal_wired.ip.gateway internal_wired.ip.gateway Description This command instructs the printer to change the internal wired print servers gateway address. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This command is only supported on ZM400/ZM600™ printers with a ZebraNet™ 10/100 Internal Print Server. Type getvar; setvar Important • This setting refers to the gateway address. A set value is ignored if the IP protocol is not set to permanent. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the internal wired printer servers gateway address. Format: ! U1 getvar "internal_wired.ip.gateway" setvar This command instructs the printer to change the internal wired printer servers gateway address. Format: ! U1 setvar "internal_wired.ip.gateway" "value" Values: Any valid gateway address Default: "0.0.0.0" Example • This setvar example shows the value set to "10.3.5.1". ! U1 setvar "internal_wired.ip.gateway" "10.3.5.1" When the setvar value is set to "10.3.5.1", the getvar result is "10.3.5.1". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wired Commands internal_wired.ip.netmask internal_wired.ip.netmask Description This setting refers to the internal wired print server’s subnet mask address. This value is ignored if the IP protocol is not set to permanent. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This command is only supported on ZM400/ZM600™ printers with a ZebraNet™ 10/100 Internal Print Server. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with internal wired print servers subnet mask. Format: ! U1 getvar "internal_wired.ip.netmask" setvar This command instructs the printer to change the internal wired print servers subnet mask. Format: ! U1 setvar "internal_wired.ip.netmask" "value" Values: Any valid subnet mask. Default: "255.255.255.0" Example • This setvar example shows the value set to "255.255.255.0". ! U1 setvar "internal_wired.ip.netmask" "255.255.255.0" When the setvar value is set to "255.255.255.0", the getvar result is "255.255.255.0". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 237 238 SGD Wired Commands internal_wired.ip.port internal_wired.ip.port Description This printer setting refers to the internal wired print servers port number that the TCP print service is listening on. Normal TCP communications from the host should be directed to this port. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This command is only supported on ZM400/ZM600™ printers with a ZebraNet™ 10/100 Internal Print Server. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the internal wired printer servers TCP/UDP port number. Format: ! U1 getvar "internal_wired.ip.port" setvar This command instructs the printer to set the internal wired print servers TCP/UDP port number. Format: ! U1 setvar "internal_wired.ip.port" "value" Values: 1 - 65535 (excluding any ports currently used by other services, such as 21, 23, 80, and 515). Default: "9100" Example • This setvar example shows the value set to "9100". ! U1 setvar "internal_wired.ip.port" "9100" When the setvar value is set to "9100", the getvar result is "9100". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wired Commands internal_wired.ip.protocol internal_wired.ip.protocol Description This command configures the IP addressing method used by the internal wired print server. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This command is only supported on ZM400/ZM600™ printers with a ZebraNet™ 10/100 Internal Print Server. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command returns the IP addressing method used by the internal wired print server. Format: ! U1 getvar "internal_wired.ip.protocol" setvar This command instructs the printer to configure the IP addressing method used by the internal wired print server. Format: ! U1 setvar "internal_wired.ip.protocol" "value" Values: "bootp" = uses the standard bootp addressing method to obtain an IP address and configuration "dhcp" = uses the standard dhcp addressing method to obtain an IP address and configuration for a server specified period of time "rarp" = uses the standard rarp addressing method to obtain an IP address "glean" = uses the IP address from a PING packet that is sent to its hardware address (unicast address) “permanent” = uses static values assigned through other commands "all" = tries all of the dynamic addressing methods, not permanent, to obtain an IP address Default: "all" Example • In this example, the setvar result is the current programming language that the printer is using. ! U1 setvar "internal_wired.ip.protocol" "bootp" What the setvar value is set to is the getvar result. In this example, the getvar result is "bootp". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 239 240 SGD Wired Commands internal_wired.ip.timeout.enable internal_wired.ip.timeout.enable Description This network setting refers to enabling the connection timeout on the internal wired print server. For this to take effect, the print server must be reset. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This command is only supported on ZM400/ZM600™ printers with a ZebraNet™ 10/100 Internal Print Server. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to return whether the timeout checking is enabled on the internal wired print server. Format: ! U1 getvar "internal_wired.ip.timeout.enable" setvar This command instructs the printer to enable or disable the timeout checking on the internal wired print server. Format: ! U1 setvar "internal_wired.ip.timeout.enable" "value" Values: "off" = turns off the connection checking "on" = turns on the connection checking Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "internal_wired.ip.timeout.enable" "on" When the setvar value is set to "on", the getvar result is "on". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wired Commands internal_wired.ip.timeout.value internal_wired.ip.timeout.value Description This network setting refers to the number of seconds before the connection times out for the internal wired print server. For this to take effect, the print server must be reset. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This command is only supported on ZM400/ZM600™ printers with a ZebraNet™ 10/100 Internal Print Server. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the time of the internal wired print server, in seconds, before the connection times out. Format: ! U1 getvar "internal_wired.ip.timeout.value" setvar This command instructs the printer to set the time of the internal wired print server, in seconds, before the connection times out. Format: ! U1 setvar "internal_wired.ip.timeout.value" "value" Values: "0" through "3600" Default: "300" Example • This setvar example shows the value set to "300". ! U1 setvar "internal_wired.ip.timeout.value" "300" When the setvar value is set to "300", the getvar result is "300". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 241 242 SGD Wired Commands internal_wired.mac_addr internal_wired.mac_addr Description This command retrieves the MAC address of the internal wired print server. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers running E53.15.xZ or later. This command is only supported on ZM400/ZM600™ printers with a ZebraNet™ 10/100 Internal Print Server. Type getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 212. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command instructs the printer to respond with the MAC address of the internal wired print server. Format: ! U1 getvar "internal_wired.mac_addr" Example • In this example, the getvar result is the MAC address of the internal wired print server. ! U1 getvar "internal_wired.mac_addr" 14245L-001 Rev. A EPL Programming Guide 5/30/07 6 SGD Wireless Commands This chapter provides a high-level overview of the wireless Set / Get / Do (SGD) commands and details on each SGD command. SGD commands are available in printers with firmware version E53.15.x or later. Note • The commands listed in this chapter are for use with the Wireless Print Server and Wireless Plus Print Server, when used with firmware version E53.15.x or later. Important • These are important points to note when using EPL, ZPL, and SGD commands: • SGD commands are case-sensitive. • EPL, ZPL, and SGD commands should be sent to the printer as separate files. • Certain settings can be controlled by EPL, ZPL, and SGD. Configuration changes made in EPL or ZPL can affect configuration changes made in SGD. • Changes made with one command type (EPL, ZPL, and SGD) will affect the data returned to the host in response to EPL, ZPL, and getvar commands. The command type (EPL, ZPL, or SGD) that was sent last determines the current setting. • Some RF cards do not support all of the SGD commands. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 244 SGD Wireless Commands Overview Overview This section describes how and why to use the Set / Get / Do (SGD) commands. It also provides an example of a typical command structure. Note • SGD commands must be terminated by a carriage return or a space and line feed. SGD commands are commands that allow you to configure all printers with firmware versions E53.15.x or later. The printer performs the specified function immediately after receiving the command. The commands are: • setvar • getvar • do setvar Command Setvar commands: • are used to configure printer settings to specific values by setting them in the printer • must be terminated by a space character or a CR/ LF (0x0D, 0x0A) Important • The setvar command and attributes must be specified in lower case. getvar Command Getvar commands: • are used to get the current value of the printer settings • must be terminated by a space character or CR/LF (0x0D, 0x0A) The printer responds with the printer setting of “?” if: • the printer setting does not exist (usually due to incorrect spelling of the printer setting) • it has not been configured yet Important • The printer settings and attributes must be specified in lower case. 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands Overview do Command Do commands: • are used to instruct the printer to perform predefined actions • must be terminated by a space character or a CR/LF (0x0D, 0x0A) Some Do commands require additional settings which must be enclosed in double quotes. Important • The values must be specified in lower case. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 245 246 SGD Wireless Commands Command Structure Command Structure It is important to understand the structure of the command and its components. A command structure illustration is provided for each command in this guide. Example • This is an example of a command structure illustration: ! U1 setvar "ip.addr" "value" 1 1 2 3 2 3 Command—always preceded with an exclamation point (!) and must be specified in lower case. A space resides between the !and U1 and between U1 and the command (setvar or getvar). Attribute—always in double quotes and must be specified in lower case. Chosen value—always in double quotes. Only applicable for setvar and do. This command must be terminated by a space character or a CR/ LF (0x0D, 0x0A). Note • Some RF cards do not support all of the SGD commands. How to Send Multiple SGD Commands For any getvar, setvar, or do command, if you issue the syntax without the "1" and use the END command followed by a space, multiple SGD commands are sent simultaneously. Example • This syntax shows how you can send multiple getvar commands: 1 2 ! U getvar "ip.telnet.enable" getvar "ip.dhcp.enable" getvar "ip.dhcp.cid_prefix" 3 1 2 3 14245L-001 Rev. A END The command portion of the string does not use the "1" after the "! U". Commands issued after the first command do not require the "! U". The string of commands is terminated by the word "END" with a space after the word, and by a carriage return/ line feed. EPL Programming Guide 5/30/07 SGD Wireless Commands card.inserted card.inserted Description This command indicates whether the wireless radio card is or is not inserted. Type getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command instructs the printer to respond with the wireless radio card status. It’s inserted or it’s not inserted. Format: ! U1 getvar "card.inserted" Example • In this example, the getvar result is "Inserted". ! U1 getvar "card.inserted" 5/30/07 EPL Programming Guide 14245L-001 Rev. A 247 248 SGD Wireless Commands card.mac_addr card.mac_addr Description This command retrieves the MAC address of the wireless radio card. Type getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command instructs the printer to respond with the MAC address. Format: ! U1 getvar "card.mac_addr" Example • In this example, the getvar result is the MAC address for the wireless radio card. ! U1 getvar "card.mac_addr" 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands ip.addr ip.addr Description This command allows you to get or set the printer’s IP address. Type getvar; setvar Important • For a set IP address to take affect, the IP protocol must be set to permanent and the print server must be reset. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with its current IP address. Format: ! U1 getvar "ip.addr" setvar This command instructs the printer to change its current IP address upon powering the printer on. Format: ! U1 setvar "ip.addr" "value" Values: any valid IP address Default: "0.0.0.0" Note • The setvar value of this command can be affected by the ip.dhcp.enable command. Example • This setvar example shows the value set to "10.14.4.235". ! U1 setvar "ip.addr" "10.14.4.235" What the setvar value is set to is the getvar result. In this example, the getvar result is "10.14.4.235". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 249 250 SGD Wireless Commands ip.arp_interval ip.arp_interval Description This printer setting allows you to specify the ARP (Address Resolution Protocol) interval or the ARP cache time out. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the ARP interval or the ARP cache time out value in seconds. Format: ! U1 getvar "ip.arp_interval" setvar This command instructs the printer to change the ARP interval or the ARP cache time out. Format: ! U1 setvar "ip.arp_interval" "value" Values: 0 - 30 Default: "0" Example • This setvar example shows the value set to "0". ! U1 setvar "ip.arp_interval" "0" What the setvar value is set to is the getvar result. In this example, the getvar result is "0". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands ip.bootp.enable ip.bootp.enable Description This printer setting turns BOOTP on or off. BOOTP is a method for acquiring an IP address, netmask, and gateway automatically on printer power-up. It requires a BOOTP server on the local network. Type getvar; setvar Note • If you are using static IP addressing, the IP protocol must be set to permanent. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the current BOOTP setting. Format: ! U1 getvar "ip.bootp.enable" setvar This command instructs the printer to turn BOOTP on or off. Format: ! U1 setvar "ip.bootp.enable" "value" Values: "off" = printer does not use BOOTP to get the IP address "on" = printer uses BOOTP to get the IP address Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "ip.bootp.enable" "on" When the setvar value is set to "on", the getvar result is "on". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 251 252 SGD Wireless Commands ip.dhcp.cid_all ip.dhcp.cid_all Description This printer setting defines the entire client identifier (DHCP option 61) if the DHCP is enabled and "ip.dhcp.cid_type" is set to "0", or "2". The MAC address is used if the type is set to "1". Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier prefix and suffix. Format: ! U1 getvar "ip.dhcp.cid_all" setvar This command instructs the printer to change the CID prefix and suffix. Format: ! U1 setvar "ip.dhcp.cid_all" "value" Values: A maximum length of 60 characters if the CID type is ASCII, or 120 characters if the CID type is hexadecimal. Default Value: "" Example • This setvar example shows the value set to "printer". ! U1 setvar "ip.dhcp.cid_all" "printer" What the setvar value is set to is the getvar result. In this example, the getvar result is "printer". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands ip.dhcp.cid_enable ip.dhcp.cid_enable Description This command determines if DHCP (option 61) is turned on or off. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the status of the client identifier. Format: ! U1 getvar "ip.dhcp.cid_enable" setvar This command instructs the printer to set the status of the client identifier. Format: ! U1 setvar "ip.dhcp.cid_enable" "value" Values: "off" = client identifier is turned off "on" = client identifier is turned on Default: "off" Example • This setvar example shows the value set to "off". ! U1 setvar "ip.dhcp.cid_enable" "off" What the setvar value is set to is the getvar result. In this example, the getvar result is "off". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 253 254 SGD Wireless Commands ip.dhcp.cid_prefix ip.dhcp.cid_prefix Description This printer setting defines the prefix to be prepended to the DHCP client identifier (option 61) when DHCP is enabled and "ip.dhcp.cid_type" is set to "0"or "2". Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier prefix. Format: ! U1 getvar "ip.dhcp.cid_prefix" setvar This command instructs the printer to change the CID prefix. Format: ! U1 setvar "ip.dhcp.cid_prefix" "value" Values: Any text string up to 10 characters if the CID type is ASCII, or 20 characters if the CID type is hexadecimal. Default Value: "" Example • This setvar example shows the value set to "PRT001". ! U1 setvar "ip.dhcp.cid_prefix" "PRT001" What the setvar value is set to is the getvar result. In this example, the getvar result is "PRT001". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands ip.dhcp.cid_suffix ip.dhcp.cid_suffix Description This printer setting defines the unique suffix to be used as the client identifier (DHCP option 61) if DHCP is enabled and "ip.dhcp.cid_type" is set to "0" or "2". Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier suffix. Format: ! U1 getvar "ip.dhcp.cid_suffix" setvar This command instructs the printer to change the CID value. Format: ! U1 setvar "ip.dhcp.cid_suffix" "value" Values: The maximum length of a value allowed is 60 ASCII characters when the CID type is ASCII, or 120 hexadecimal values when the CID type is hexadecimal. Default Value: "" Example • This setvar example shows the value set to "printer". ! U1 setvar "ip.dhcp.cid_suffix" "printer" What the setvar value is set to is the getvar result. In this example, the getvar result is "printer". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 255 256 SGD Wireless Commands ip.dhcp.cid_type ip.dhcp.cid_type Description This printer setting defines the type of client identifier (DHCP option 61) that will be sent if DHCP is enabled. A value of "1" means the type of "Ethernet" and the printer’s MAC address will be used. A value of "0" or "2" means the client identifier sent will be "ip.dhcp.cid_prefix" concatenated with "ip.dhcp.cid_suffix". Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier type. Format: ! U1 getvar "ip.dhcp.cid_type" setvar This command instructs the printer to enable "synthetic" Client Identifier. Format: ! U1 setvar "ip.dhcp.cid_type" "value" Values: "0" = ASCII string "1" = wireless radio card’s MAC address "2" = HEX value Default Value: "1" Example • This setvar example shows the value set to "1". ! U1 setvar "ip.dhcp.cid_type" "1" What the setvar value is set to is the getvar result. In this example, the getvar result is "1". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands ip.dhcp.enable ip.dhcp.enable Definition This printer setting turns DHCP on or off. DHCP is a method for acquiring an IP address, netmask, and gateway automatically on printer power-up. It requires a DHCP server on the local network. Type getvar; setvar Note • If you are using static IP addressing, the IP protocol must be set to permanent. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the DHCP status. Format: ! U1 getvar "ip.dhcp.enable" setvar This command instructs the printer to turn DHCP on or off. Format: ! U1 setvar "ip.dhcp.enable" "value" Values: "off" = printer does not use DHCP to get the IP address "on" = printer uses DHCP to get the IP address Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "ip.dhcp.enable" "on" When the setvar value is set to "on", the getvar result is "on". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 257 258 SGD Wireless Commands ip.gateway ip.gateway Description This command instructs the printer to change the gateway address. Type getvar; setvar Note • This setting refers to the gateway address. A set value is ignored if the IP protocol is not set to permanent. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the gateway address. Format: ! U1 getvar "ip.gateway" setvar This command instructs the printer to change the gateway address. Format: ! U1 setvar "ip.gateway" "value" Values: Any valid gateway address Default: "0.0.0.0" Example • This setvar example shows the value set to "10.3.5.1". ! U1 setvar "ip.gateway" "10.3.5.1" When the setvar value is set to "10.3.5.1", the getvar result is "10.3.5.1". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands ip.netmask ip.netmask Description This setting refers to the subnet mask address. This value is ignored if the IP protocol is not set to permanent. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with subnet mask. Format: ! U1 getvar "ip.netmask" setvar This command instructs the printer to change the subnet mask. Format: ! U1 setvar "ip.netmask" "value" Values: Any valid subnet mask. Default: "255.255.255.0" Example • This setvar example shows the value set to "255.255.255.0". ! U1 setvar "ip.netmask" "255.255.255.0" When the setvar value is set to "255.255.255.0", the getvar result is "255.255.255.0". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 259 260 SGD Wireless Commands ip.port ip.port Description This printer setting refers to the port number that the TCP print service is listening on. Normal TCP communications from the host should be directed to this port. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the TCP/UDP port number. Format: ! U1 getvar "ip.port" setvar This command instructs the printer to set the TCP/UDP port number. Format: ! U1 setvar "ip.port" "value" Values: 1 - 65535 (excluding any ports currently used by other services, such as 21, 23, 80, and 515). Default: "9100" Example • This setvar example shows the value set to "9100". ! U1 setvar "ip.port" "9100" When the setvar value is set to "9100", the getvar result is "9100". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.adhocautomode wlan.adhocautomode Description This printer setting refers to enabling or disabling the adhoc auto mode. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the adhoc auto mode status. Format: ! U1 getvar "wlan.adhocautomode" setvar This command instructs the printer to set the adhoc auto mode. Format: ! U1 setvar "wlan.adhocautomode" "value" Values: "on" = adhoc auto mode enabled "off" = adhoc auto mode disabled Default: "off" Example • This setvar example shows the value set to "on". ! U1 setvar "wlan.adhocautomode" "on" When the setvar value is set to "on", the getvar result is "on". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 261 262 SGD Wireless Commands wlan.adhocchannel wlan.adhocchannel Description This printer setting refers to specifying the wireless channel for adhoc channel. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the wireless channel for adhoc channel mode. Format: ! U1 getvar "wlan.adhocchannel" setvar This command instructs the printer to set the wireless channel for adhoc channel mode. Format: ! U1 setvar "wlan.adhocchannel" "value" Values: Decimal value between 1 and 16 inclusive Default: "1" Example • This setvar example shows the value set to "1". ! U1 setvar "wlan.adhocchannel" "1" When the setvar value is set to "1", the getvar result is "1". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.associated wlan.associated Description This command refers to if the printer is or is not associated with an access point (AP). Type getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with yes or no, which identifies if it is associated with the AP. Format: ! U1 getvar "wlan.associated" Example • In this example, the getvar result is "yes". ! U1 getvar "wlan.associated" 5/30/07 EPL Programming Guide 14245L-001 Rev. A 263 264 SGD Wireless Commands wlan.channel_mask wlan.channel_mask Description This printer setting refers to specifying the wireless channel masks to enable and disable various channels. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the wireless channel mask value. Format: ! U1 getvar "wlan.channel_mask" setvar This command instructs the printer to set the wireless channel mask value. Format: ! U1 setvar "wlan.channel_mask" "value" Values: 4 Hexadecimal digits preceded by "0x" (0x0000 to 0xFFFF). For commonly used channel masks, see Table 6 on page 264. Default: "0x7FF" Table 6 • Channel Mask Settings Channel Mask Region United States, Canada, Latin America 0x7FF Europe, Middle East, Africa, other 0x1FFF Japan 0x3FFF Example • This setvar example shows the value set to "0x7FF". ! U1 setvar "wlan.channel_mask" "0x7FF" When the setvar value is set to "0x7FF", the getvar result is "0x7FF". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.essid wlan.essid Description This printer setting refers to the printer’s stored ESSID. Setting the ESSID to "" will set the printer in a "broadcast" mode. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the stored ESSID value. Format: ! U1 getvar "wlan.essid" setvar This command instructs the printer to change the ESSID. Format: ! U1 setvar "wlan.essid" "value" Values: 32 character alphanumeric string Default: "125" Example • This setvar example shows the value set to "125". ! U1 setvar "wlan.essid" "125" When the setvar value is set to "125", the getvar result is "125". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 265 266 SGD Wireless Commands wlan.firmware_version wlan.firmware_version Description This command refers to the firmware version of the wireless radio card. Type getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the current version of the wireless radio card firmware. Format: ! U1 getvar "wlan.firmware_version" Example • In this example, the getvar result is the version of Symbol 4137 card (for example, "F3.91-69"). ! U1 getvar "wlan.firmware_version" 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.ip.addr wlan.ip.addr Description This command allows you to get or set the wireless print servers’s IP address. This command is supported only on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Important • For a set IP address to take affect, the IP protocol must be set to permanent and the print server must be reset. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with its current wireless print server IP address. Format: ! U1 getvar "wlan.ip.addr" setvar This command instructs the printer to change its current wireless print server IP address upon powering the printer on. Format: ! U1 setvar "wlan.ip.addr" "value" Values: any valid IP address Default: "0.0.0.0" Note • The setvar value of this command can be affected by the wlan.ip.dhcp.enable command. Example • This setvar example shows the value set to "10.14.4.235". ! U1 setvar "wlan.ip.addr" "10.14.4.235" What the setvar value is set to is the getvar result. In this example, the getvar result is "10.14.4.235". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 267 268 SGD Wireless Commands wlan.ip.arp_interval wlan.ip.arp_interval Description This print server setting allows you to specify the ARP (Address Resolution Protocol) interval or the ARP cache time out for the wireless print server. This command is supported only on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Important • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the ARP interval or the ARP cache time out value (in seconds) for the wireless print server. Format: ! U1 getvar "wlan.ip.arp_interval" setvar This command instructs the printer to change the ARP interval or the ARP cache time out for the wireless print server. Format: ! U1 setvar "wlan.ip.arp_interval" "value" Values: 0 - 30 Default: "0" Example • This setvar example shows the value set to "0". ! U1 setvar "wlan.ip.arp_interval" "0" What the setvar value is set to is the getvar result. In this example, the getvar result is "0". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.ip.default_addr.enable wlan.ip.default_addr.enable Description This command allows you to default the wireless print server’s IP address. This command is only supported on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Important • For a set IP address to take affect, the IP protocol must be set to permanent and the print server must be reset. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to show the status of the setting of the wireless print server’s default IP address feature. Format: ! U1 getvar "wlan.ip.default_addr.enable" setvar This command tells the printer to use it’s default address, if no address is provided through DHCP or BOOTP. If you do not assign an IP address after 2 minutes, the 10/100 Internal PS defaults to IP address 192.168.254.254. Format: ! U1 setvar "wlan.ip.default_addr.enable" "value" Values: "on" = enabled "off" = disabled Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "wlan.ip.default_addr.enable" "on" What the setvar value is set to is the getvar result. In this example, the getvar result is "on". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 269 270 SGD Wireless Commands wlan.ip.dhcp.cid_all wlan.ip.dhcp.cid_all Description This printer setting defines the entire client identifier (DHCP option 61) if DHCP is enabled on the wireless print server and "wlan.ip.dhcp.cid_type" is set to "0", or "2". The MAC address is used if the type is set to "1". This command is supported only on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier prefix and suffix of the wireless print server. Format: ! U1 getvar "wlan.ip.dhcp.cid_all" setvar This command instructs the printer to change the client identifer prefix and suffix of the wireless print server. The prefix gets cleared and the suffix contains the entire client identifer. Format: ! U1 setvar "wlan.ip.dhcp.cid_all" "value" Values: A maximum length of 60 characters if the CID type is ASCII, or 120 characters if the CID type is hexadecimal. Default Value: "" Example • This setvar example shows the value set to "printer". ! U1 setvar "wlan.ip.dhcp.cid_all" "printer" What the setvar value is set to is the getvar result. In this example, the getvar result is "printer". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.ip.dhcp.cid_enable wlan.ip.dhcp.cid_enable Description This command determines if DHCP (option 61) is turned on or off of the wireless print server. This command is supported only on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the status of the client identifier of the wireless print server. Format: ! U1 getvar "wlan.ip.dhcp.cid_enable" setvar This command instructs the printer to set the status of the client identifier of the wireless print server. Format: ! U1 setvar "wlan.ip.dhcp.cid_enable" "value" Values: "off" = client identifier is turned off "on" = client identifier is turned on Default: "off" Example • This setvar example shows the value set to "off". ! U1 setvar "wlan.ip.dhcp.cid_enable" "off" What the setvar value is set to is the getvar result. In this example, the getvar result is "off". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 271 272 SGD Wireless Commands wlan.ip.dhcp.cid_prefix wlan.ip.dhcp.cid_prefix Description This printer setting defines the prefix to be prepended to the DHCP client identifier (option 61) when DHCP is enabled on the wireless print server and "wlan.ip.dhcp.cid_type" is set to "0" or "2". This command is supported only on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier prefix of the wireless print server. Format: ! U1 getvar "wlan.ip.dhcp.cid_prefix" setvar This command instructs the printer to change the CID prefix of the wireless print server. Format: ! U1 setvar "wlan.ip.dhcp.cid_prefix" "value" Values: Any text string up to 10 characters if the CID type is ASCII, or 20 characters if the CID type is hexadecimal. Default Value: "" Example • This setvar example shows the value set to "PRT001". ! U1 setvar "wlan.ip.dhcp.cid_prefix" "PRT001" What the setvar value is set to is the getvar result. In this example, the getvar result is "PRT001". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.ip.dhcp.cid_suffix wlan.ip.dhcp.cid_suffix Description This printer setting defines the unique suffix to be used as the client identifier (DHCP option 61) if DHCP is enabled on the wireless print server and "wlan.ip.dhcp.cid_type" is set to "0" or "2". Type getvar; setvar Important • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier suffix on the wireless print server. Format: ! U1 getvar "wlan.ip.dhcp.cid_suffix" setvar This command instructs the printer to change the client identifier suffix value on the wireless print server. Format: ! U1 setvar "wlan.ip.dhcp.cid_suffix" "value" Values: The maximum length of a value allowed is 60 ASCII characters when the CID type is ASCII, or 120 hexadecimal values when the CID type is hexadecimal. Default Value: "" Example • This setvar example shows the value set to "printer". ! U1 setvar "wlan.ip.dhcp.cid_suffix" "printer" What the setvar value is set to is the getvar result. In this example, the getvar result is "printer". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 273 274 SGD Wireless Commands wlan.ip.dhcp.cid_type wlan.ip.dhcp.cid_type Description This printer setting defines the type of client identifier (DHCP option 61) that will be sent if DHCP is enabled on the wireless print server. A value of "1" means the type of "Ethernet" and the printer’s MAC address will be used. A value of "0" or "2" means the client identifier sent will be "wlan.ip.dhcp.cid_prefix" concatenated with "wlan.ip.dhcp.cid_suffix". This command is supported only on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the client identifier type for the wireless print server. Format: ! U1 getvar "wlan.ip.dhcp.cid_type" setvar This command instructs the printer to enable "synthetic" client identifier for the wireless print server. Format: ! U1 setvar "wlan.ip.dhcp.cid_type" "value" Values: "0" = ASCII string "1" = wireless radio card’s MAC address "2" = HEX value Default Value: "1" Example • This setvar example shows the value set to "1". ! U1 setvar "wlan.ip.dhcp.cid_type" "1" What the setvar value is set to is the getvar result. In this example, the getvar result is "1". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.ip.gateway wlan.ip.gateway Description This command instructs the printer to change the wireless print server’s gateway address. This command is supported only on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Note • This setting refers to the gateway address. A set value is ignored if the IP protocol is not set to permanent. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the wireless printer server’s gateway address. Format: ! U1 getvar "wlan.ip.gateway" setvar This command instructs the printer to change the wireless printer server’s gateway address. Format: ! U1 setvar "wlan.ip.gateway" "value" Values: Any valid gateway address Default: "0.0.0.0" Example • This setvar example shows the value set to "10.3.5.1". ! U1 setvar "wlan.ip.gateway" "10.3.5.1" When the setvar value is set to "10.3.5.1", the getvar result is "10.3.5.1". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 275 276 SGD Wireless Commands wlan.ip.netmask wlan.ip.netmask Description This setting refers to the wireless print server’s subnet mask address. This value is ignored if the IP protocol is not set to permanent. This command is supported only on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with wireless print server’s subnet mask. Format: ! U1 getvar "wlan.ip.netmask" setvar This command instructs the printer to change the wireless print servers’s subnet mask. Format: ! U1 setvar "wlan.ip.netmask" "value" Values: Any valid subnet mask. Default: "255.255.255.0" Example • This setvar example shows the value set to "255.255.255.0". ! U1 setvar "wlan.ip.netmask" "255.255.255.0" When the setvar value is set to "255.255.255.0", the getvar result is "255.255.255.0". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.ip.port wlan.ip.port Description This printer setting refers to the wireless print server’s port number that the TCP print service is listening on. Normal TCP communications from the host should be directed to this port.This command is supported only on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the wireless printer server’s TCP/UDP port number. Format: ! U1 getvar "wlan.ip.port" setvar This command instructs the printer to set the wireless print server’s TCP/UDP port number. Format: ! U1 setvar "wlan.ip.port" "value" Values: 1 - 65535 (excluding any ports currently used by other services, such as 21, 23, 80, and 515). Default: "9100" Example • This setvar example shows the value set to "9100". ! U1 setvar "wlan.ip.port" "9100" When the setvar value is set to "9100", the getvar result is "9100". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 277 278 SGD Wireless Commands wlan.ip.protocol wlan.ip.protocol Description This command configures the IP addressing method used by the wireless print server. This command is supported only on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command returns the value of the currently selected IP protocol used by the wireless print server. Format: ! U1 getvar "wlan.ip.protocol" setvar This command instructs the printer to configure the IP addressing method used by the wireless print server. Format: ! U1 setvar "wlan.ip.protocol" "value" Values: "bootp" = uses the standard bootp addressing method to obtain an IP address and configuration "dhcp" = uses the standard dhcp addressing method to obtain an IP address and configuration for a server specified period of time "rarp" = uses the standard rarp addressing method to obtain an IP address "glean" = uses the IP address from a PING packet that is sent to its hardware address (unicast address) “permanent” = uses static values assigned through other commands "all" = tries all of the dynamic addressing methods, not permanent, to obtain an IP address Default: "all" Example • In this example, the setvar result is the current programming language that the printer is using. ! U1 setvar "wlan.ip.protocol" "bootp" What the setvar value is set to is the getvar result. In this example, the getvar result is "bootp". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.ip.timeout.enable wlan.ip.timeout.enable Description This network setting refers to enabling the connection timeout on the wireless print server. For this to take effect, the print server must be reset. This command is supported only on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to return whether the timeout checking is enabled on the wireless print server. Format: ! U1 getvar "wlan.ip.timeout.enable" setvar This command instructs the printer to enable or disable the timeout checking on the wireless print server. Format: ! U1 setvar "wlan.ip.timeout.enable" "value" Values: "off" = turns off the connection checking "on" = turns on the connection checking Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "wlan.ip.timeout.enable" "on" When the setvar value is set to "on", the getvar result is "on". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 279 280 SGD Wireless Commands wlan.ip.timeout.value wlan.ip.timeout.value Description This network setting refers to the number of seconds before the connection times out for the wireless print server. For this to take effect, the print server must be reset. This command is supported only on Zebra ZM400/ZM600™ and S4M™ printers. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the time, in seconds, before the connection times out. Format: ! U1 getvar "wlan.ip.timeout.value" setvar This command instructs the printer to set the the time value of the wireless print server, in seconds, before the connection times out. Format: ! U1 setvar "wlan.ip.timeout.value" "value" Values: "0" through "3600" Default: "300" Example • This setvar example shows the value set to "300". ! U1 setvar "wlan.ip.timeout.value" "300" When the setvar value is set to "300", the getvar result is "300". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.keep_alive.enable wlan.keep_alive.enable Description This setting controls the printers ability to send a LSAP (link service access point) packet to the access point on an user controllable interval. This feature is included to accommodate access points that require a regular confirmation that wireless clients are still active. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the wlan.keep_alive.enable setting. Format: ! U1 getvar "wlan.keep_alive.enable" setvar This command instructs the printer to send a LSAP (link service access point) packet to the access point on an user controllable interval. Format: ! U1 setvar "wlan.keep_alive.enable" "value" Values: "on" = turns on keep_alive "off" = turns off keep_alive Default: "on" Example • This setvar example shows the value set to "on". ! U1 setvar "wlan.keep_alive.enable" "on" When the setvar value is set to "on", the getvar result is "on". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 281 282 SGD Wireless Commands wlan.keep_alive.timeout wlan.keep_alive.timeout Description This printer setting manages the interval at which the LSAP (link service access point) packet is sent. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the wlan.keep_alive.timeout interval value. Format: ! U1 getvar "wlan.keep_alive.timeout" setvar This command instructs the printer to configure the frequency at which the printer sends the wlan.keep_alive packet. Format: ! U1 setvar "wlan.keep_alive.timeout" "value" Values: 5 to 300 seconds Default: "15" Example • This setvar example shows the value set to "15". ! U1 setvar "wlan.keep_alive.timeout" "15" When the setvar value is set to "15", the getvar result is "15". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.kerberos.kdc wlan.kerberos.kdc Description This printer setting refers to the Kerberos Key Distribution Center (KDC). The KDC is a trusted server which maintains a database with account information for all security principals (users) for a particular site or administrative domain (realm). Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the current Kerberos KDC. Format: ! U1 getvar "wlan.kerberos.kdc" setvar This command instructs the printer to change the Kerberos KDC. Format: ! U1 setvar "wlan.kerberos.kdc" "value" Values: 0-32 ASCII characters Default: "krbtgt" Example • This setvar example shows the value set to "krbtgt". ! U1 setvar "wlan.kerberos.kdc" "krbtgt" When the setvar value is set to "krbtgt", the getvar result is "krbtgt". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 283 284 SGD Wireless Commands wlan.kerberos.password wlan.kerberos.password Description This printer setting refers to the Kerberos password. The password must correspond to a user profile established on the Kerberos KDC server in use. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the current Kerberos password. Format: ! U1 getvar "wlan.kerberos.password" For protection a single "*" prints. setvar This command instructs the printer to set the Kerberos password. Format: ! U1 setvar "wlan.kerberos.password" "value" Values: 0-32 alphanumeric characters Default: "password" Example • This setvar example shows the value set to "password". ! U1 setvar "wlan.kerberos.password" "password" When the setvar value is set to "password", the getvar result is "*". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.kerberos.realm wlan.kerberos.realm Description This printer setting refers to the Kerberos realm, an administrative domain with its own Kerberos server (KDC). Type getvar; setvar Important • If you are using a Windows 2000 Server the realm must be all upper-case. For details, see the Windows 2000 Server example below. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the current Kerberos realm. Format: ! U1 getvar "wlan.kerberos.realm" setvar This command instructs the printer to change the Kerberos realm. Format: ! U1 setvar "wlan.kerberos.realm" "value" Values: 0-64 alphanumeric characters Default: "kerberos" Example • This setvar example shows the value set to "zebra". ! U1 setvar "wlan.kerberos.realm" "zebra" When the setvar value is set to "zebra", the getvar result is "zebra". Example • This setvar example shows the value set to "ZEBRA" on a Windows 2000 server. ! U1 setvar "wlan.kerberos.realm" "ZEBRA" When the setvar value is set to "ZEBRA", the getvar result is "ZEBRA". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 285 286 SGD Wireless Commands wlan.kerberos.username wlan.kerberos.username Description This printer setting refers to the Kerberos user name. The user name must correspond to a user profile established on the Kerberos KDC server in use. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the current Kerberos user name. Format: ! U1 getvar "wlan.kerberos.username" setvar This command instructs the printer to change the Kerberos user name. Format: ! U1 setvar "wlan.kerberos.username" "value" Values: 0-32 alphanumeric characters Default: "user" Example • This setvar example shows the value set to "user". ! U1 setvar "wlan.kerberos.username" "user" When the setvar value is set to "user", the getvar result is "user". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.mac_addr wlan.mac_addr Description This command retrieves the MAC address of the wireless print server. This command is supported only on Zebra ZM400/ZM600™ printers. Type getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command instructs the printer to respond with the MAC address of the wireless print server. Format: ! U1 getvar "wlan.mac_addr" Example • In this example, the getvar result is the MAC address for the wireless print server. ! U1 getvar "wlan.mac_addr" 5/30/07 EPL Programming Guide 14245L-001 Rev. A 287 288 SGD Wireless Commands wlan.operating_mode wlan.operating_mode Description This printer setting refers to the network operating mode. Infrastructure mode means that the printer will try to associate with an access point. Ad hoc mode means that the printer will try to associate with a device other than an access point and join a standalone network. Type getvar; setvar To use "ad hoc" mode configure the printer as follows: • Set the ESSID to the new network’s ESSID. • Turn off the DHCP and assign an IP Address to the printer. • Set the subnet mask on the printer to the new network’s subnet mask. • Change the operating mode on the printer to "ad hoc". Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the network-mode value. Format: ! U1 getvar "wlan.operating_mode" setvar This command instructs the printer to set the network operating mode. Format: ! U1 setvar "wlan.operating_mode" "value" Values: "adhoc" = printer will try to associate with a network device "infrastructure" = printer will try to associate with an access point Default: "infrastructure" Example • This setvar example shows the value set to "infrastructure". ! U1 setvar "wlan.operating_mode" "infrastructure" When the setvar value is set to "infrastructure", the getvar result is "infrastructure". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.password wlan.password Description This printer setting refers to the generic password that is used by the wireless securities that need a password. Type getvar; setvar Important • Kerberos has its own password field Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with a generic password for wireless securities. Format: ! U1 getvar "wlan.password" For protection a single "*" prints. setvar This command instructs the printer to set a generic password for the wireless securities that need a password. Format: ! U1 setvar "wlan.password" "value" Values: A maximum of 32 alphanumeric characters. Default: "password" Example • This setvar example shows the value set to "password". ! U1 setvar "wlan.password" "password" When the setvar value is set to "password", the getvar result is "*". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 289 290 SGD Wireless Commands wlan.preamble wlan.preamble Description This printer setting selects the radio preamble length to be used. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the current preamble length. Format: ! U1 getvar "wlan.preamble" setvar This command instructs the printer to set the preamble length. Format: ! U1 setvar "wlan.preamble" "value" Values: "long" = enables long preamble "short" = enables short preamble Default: "long" Example • This setvar example shows the value set to "long". ! U1 setvar "wlan.preamble" "long" When the setvar value is set to "long", the getvar result is "long". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.private_key_password wlan.private_key_password Description This printer setting allows the setting of the optional private key password. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the value of the private key password. Format: ! U1 getvar "wlan.private_key_password" For protection a single "*" prints. setvar This command instructs the printer to set the private key password. Format: ! U1 setvar "wlan.private_key_password" "value" Values: A maximum of 32 alphanumeric characters Default: "" Example • This setvar example shows the value set to "password". ! U1 setvar "wlan.private_key_password" "password" When the setvar value is set to "password", the getvar result is "*". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 291 292 SGD Wireless Commands wlan.roam.interval wlan.roam.interval Description This printer setting refers to specifying the wireless roam interval. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the specified roam interval. Format: ! U1 getvar "wlan.roam.interval" setvar This command instructs the printer to set the wireless roam interval. Format: ! U1 setvar "wlan.roam.interval" "value" Values: Decimal values between 5 and 255 inclusive Default: "20" Example • This setvar example shows the value set to "20". ! U1 setvar "wlan.roam.interval" "20" When the setvar value is set to "20", the getvar result is "20". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.roam.signal wlan.roam.signal Description This printer setting refers to specifying the wireless roam signal. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the specified wireless roam signal. Format: ! U1 getvar "wlan.roam.signal" setvar This command instructs the printer to set the wireless roam signal. Format: ! U1 setvar "wlan.roam.signal" "value" Values: Decimal values between 1 and 75 inclusive. Default: "50" Example • This setvar example shows the value set to "50". ! U1 setvar "wlan.roam.signal" "50" When the setvar value is set to "50", the getvar result is "50". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 293 294 SGD Wireless Commands wlan.security wlan.security Description This printer setting allows you to specify both the wireless encryption type and authentication type in one command. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. Note • When using certificate files, Zebra printers support: • using Privacy Enhanced Mail (PEM) formatted certificate files. • using the client certificate and private key as two files, each downloaded separately. • using exportable PAC files for EAP-FAST. These certificate files can only be sent using ZPL, not SGD. The ZPL command to use when sending these certificate files is the ~DY command. 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.security This table identifies the commands for this format: Commands Details getvar This command instructs the printer to return the name and not the type. If an invalid security mode is entered the printer returns Invalid Mode. Format: ! U1 getvar "wlan.security" "value" setvar This command instructs the printer to set the wireless security value. Format: ! U1 setvar "wlan.security" "value" Values: "1" = No Security or "none" "2" = WEP 40-bit or "wep 40-bit" "3" = WEP 128-bit or "wep 128-bit" "4" = EAP-TLS or "eap-tls" "5" = EAP-TTLS or "eap-ttls" "6" = EAP-FAST or "eap-fast" "7" = PEAP or "peap" "8" = LEAP or "leap" "9" = WPA PSK or "wpa psk" "10" = WPA EAP-TLS or "wpa eap-tls" "11" = WPA EAP-TTLS or "wpa eap-ttls" "12" = WPA EAP-FAST or "wpa eap-fast" "13" = WPA PEAP or "wpa peap" "14" = WPA LEAP or "wpa leap" Default: "1" Example • This setvar example shows the value set to "1". ! U1 setvar "wlan.security" "1" When the setvar value is set to "1", the getvar result is "none". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 295 296 SGD Wireless Commands wlan.signal_noise wlan.signal_noise Description This command returns the signal noise on the wireless network. Values above 40% represent a very a very significant noise, and radio communication is not reliable. Type getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command instructs the printer to return the current signal noise on the wireless network. Format: ! U1 getvar "wlan.signal_noise" Example • In this example, the getvar result is the current signal_noise value. ! U1 getvar "wlan.signal_noise" 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.signal_quality wlan.signal_quality Description This command instructs the printer to return the current signal quality of the wireless network. Values below 40% represent a poor signal quality, and radio communication is not reliable. Type getvar Note • .These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command instructs the printer to return the current signal quality of the wireless network. Format: ! U1 getvar "wlan.signal_quality" Example • In this example, the getvar result is the current signal_quality value. ! U1 getvar "wlan.signal_quality" 5/30/07 EPL Programming Guide 14245L-001 Rev. A 297 298 SGD Wireless Commands wlan.signal_strength wlan.signal_strength Description This command returns the signal strength of the connection to the access point as a percentage value between zero (not connected) and 100 (strongest signal). Values below 40% represent a very poor signal and radio communication is not reliable. Type getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the command for this format: Commands Details getvar This command instructs the printer to respond with the current signal strength. Format: ! U1 getvar "wlan.signal_strength" Example • In this example, the getvar result is "93". ! U1 getvar "wlan.signal_strength" 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.station_name wlan.station_name Description This printer setting refers to the station name. Type setvar;getvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the station name value. Format: ! U1 getvar "wlan.station_name" setvar This command instructs the printer to set the station name. Format: ! U1 setvar "wlan.station_name" "value" Values: A maximum of 32 alphanumeric characters Default: "ZEBRA" Example • This setvar example shows the value set to "ZEBRA". ! U1 setvar "wlan.station_name" "ZEBRA" When the setvar value is set to "ZEBRA", the getvar result is "ZEBRA". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 299 300 SGD Wireless Commands wlan.tx_power wlan.tx_power Description This printer setting refers to specifying the wireless transmit power. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the wireless transmit power. Format: ! U1 getvar "wlan.tx_power" setvar This command instructs the printer to set the wireless transmit power. Format: ! U1 setvar "wlan.tx_power" "value" Values: Decimal values of 1, 5, 20, 30, 50, 100 Default: "100" Example • This setvar example shows the value set to "100". ! U1 setvar "wlan.tx_power" "100" When the setvar value is set to "100", the getvar result is "100". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.tx_rate wlan.tx_rate Description This printer setting refers to specifying the wireless transmit rate. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the wireless transmit rate. Format: ! U1 getvar "wlan.tx_rate" setvar This command instructs the printer to set the wireless transmit rate. Format: ! U1 setvar "wlan.tx_rate" "value" Values: 1, 2, 5.5, 11, all Default: "all" Example • This setvar example shows the value set to "all". ! U1 setvar "wlan.tx_rate" "all" When the setvar value is set to "all", the getvar result is "all". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 301 302 SGD Wireless Commands wlan.username wlan.username Description This printer setting refers to the generic user name that is used by the wireless securities that need a user name. Type getvar; setvar Important • Kerberos has its own user name field. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with a generic user name for the wireless securities that need a user name. Format: ! U1 getvar "wlan.username" setvar This command instructs the printer to set a generic user name for wireless securities that need a user name. Format: ! U1 setvar "wlan.username" "value" Values: A maximum of 32 alphanumeric characters Default: "user" Example • This setvar example shows the value set to "user". ! U1 setvar "wlan.username" "user" When the setvar value is set to "user", the getvar result is "user". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.wep.auth_type wlan.wep.auth_type Description For the WEP security type, this printer setting selects the authentication type to be used between the printer and the access point. The authentication types are open system and shared key. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to retrieve the current WEP authentication type. Format: ! U1 getvar "wlan.wep.auth_type" setvar This command instructs the printer to set the WEP authentication type. Format: ! U1 setvar "wlan.wep.auth_type" "value" Values: "open" = enables the open authentication type "shared" = enables the shared authentication type Default: "open" Example • This setvar example shows the value set to "open". ! U1 setvar "wlan.wep.auth_type" "open" When the setvar value is set to "open", the getvar result is "open". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 303 304 SGD Wireless Commands wlan.wep.index wlan.wep.index Description This printer setting refers to the WEP (Wired Equivalent Privacy) encryption key index. This printer setting determines which one of the four encryption keys is to be used by the client (printer). Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the encryption key index. Format: ! U1 getvar "wlan.wep.index" setvar This command instructs the printer to set the encryption key index. Format: ! U1 setvar "wlan.wep.index" "value" Values: "1" = enables encryption key 1 "2" = enables encryption key 2 "3" = enables encryption key 3 "4" = enables encryption key 4 Default: "1" Example • This setvar example shows the value set to "1". ! U1 setvar "wlan.wep.index" "1" When the setvar value is set to "1", the getvar result is "1". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.wep.key1 wlan.wep.key1 Description This printer setting refers to the first indexed WEP encryption key. The WEP encryption key is a hexadecimal or string value. This key should match the wireless network WEP encryption key 1. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the encryption key. Format: ! U1 getvar "wlan.wep.key1" For protection a single "*" prints. setvar This command instructs the printer to set the encryption key. Format: ! U1 setvar "wlan.wep.key1" "value" Values: 10 hexadecimal characters for 40-bit encryption 26 hexadecimal characters for 128-bit encryption Default: All zeros Example • This setvar example shows the value set to "A1B2C3D4F5". ! U1 setvar "wlan.wep.key1" "A1B2C3D4F5" When the setvar value is set to "A1B2C3D4F5", the getvar result is "*". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 305 306 SGD Wireless Commands wlan.wep.key2 wlan.wep.key2 Description This printer setting refers to the second indexed WEP encryption key. The WEP encryption key is a hexadecimal string value. This key should match the wireless network WEP encryption key 2. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer respond with the encryption key. Format: ! U1 getvar "wlan.wep.key2" For protection a single "*" prints. setvar This command instructs the printer to set the encryption key. Format: ! U1 setvar "wlan.wep.key2" "value" Values: 10 hexadecimal characters for 40-bit encryption 26 hexadecimal characters for 128-bit encryption Default: All zeros Example • This setvar example shows the value set to "A1B2C3D4F5". ! U1 setvar "wlan.wep.key2" "A1B2C3D4F5" When the setvar value is set to "A1B2C3D4F5", the getvar result is "*". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.wep.key3 wlan.wep.key3 Description This printer setting refers to the third indexed WEP encryption key. The WEP encryption key is a hexadecimal string value. This key should match the wireless network WEP encryption key 3. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the encryption key. Format: ! U1 getvar "wlan.wep.key3" Format: For protection a single "*" prints. setvar This command instructs the printer to set the encryption key. Format: ! U1 setvar "wlan.wep.key3" "value" Values: 10 hexadecimal characters for 40-bit encryption 26 hexadecimal characters for 128-bit encryption Default: All zeros Example • This setvar example shows the value set to "A1B2C3D4F5". ! U1 setvar "wlan.wep.key3" "A1B2C3D4F5" When the setvar value is set to "A1B2C3D4F5", the getvar result is "*". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 307 308 SGD Wireless Commands wlan.wep.key4 wlan.wep.key4 Description This printer setting refers to the fourth indexed WEP encryption key. The WEP encryption key is a hexadecimal string value. This key should match the wireless network WEP encryption key 4. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer respond with the encryption key. Format: ! U1 getvar "wlan.wep.key4" For protection a single "*" prints. setvar This command instructs the printer to set the encryption key. Format: ! U1 setvar "wlan.wep.key4" "value" Values: 10 hexadecimal characters for 40-bit encryption 26 hexadecimal characters for 128-bit encryption Default: All zeros Example • This setvar example shows the value set to "A1B2C3D4F5". ! U1 setvar "wlan.wep.key4" "A1B2C3D4F5" When the setvar value is set to "A1B2C3D4F5", the getvar result is "*". 14245L-001 Rev. A EPL Programming Guide 5/30/07 SGD Wireless Commands wlan.wep.key_format wlan.wep.key_format Description This printer setting specifies the format for the WEP key. Type getvar; setvar Important • This printer setting should proceed any of the wep.key settings if you select a non-default value. Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the WEP key format. Format: ! U1 getvar "wep.key_format" setvar This command instructs the printer to set the WEP key format. Format: ! U1 setvar "wlan.wep.key_format" "value" Values: "ascii" = WEP key is set by ASCII string "hex" = WEP key is a Hex string Default: "hex" Example • This setvar example shows the value set to "ascii". ! U1 setvar "wlan.wep.key_format" "ascii" When the setvar value is set to "ascii", the getvar result is "ascii". 5/30/07 EPL Programming Guide 14245L-001 Rev. A 309 310 SGD Wireless Commands wlan.wpa.psk wlan.wpa.psk Description This printer setting specifies the pre-shared key (PSK) value to use when the WPA authentication is set to PSK. Type getvar; setvar Note • These are key reference links for this command: • For details on SGD command structure, see Command Structure on page 246. • For details on the syntax and use of SGD commands, see SGD Command Support on page 311. This table identifies the commands for this format: Commands Details getvar This command instructs the printer to respond with the pre-shared key. Format: ! U1 getvar "wlan.wpa.psk" For protection a single "*" prints. setvar This command instructs the printer to set the pre-shared key. Format: ! U1 setvar "wlan.wpa.psk" "value" Values: 64 hexadecimal digits Default: 64 zeros (00000000...) Example • This setvar example shows the value set to "00000000...". ! U1 setvar "wlan.wpa.psk" "00000000..." When the setvar value is set to "00000000...", the getvar result is "*". 14245L-001 Rev. A EPL Programming Guide 5/30/07 A SGD Command Support This appendix provides you with details identifying which SGD commands can be used with the wired and wireless print server interfaces. 5/30/07 EPL Programming Guide 14245L-001 Rev. A 312 SGD Command Support Printer and Firmware Compatibility Printer and Firmware Compatibility Table 7 identifies the supported printer model, firmware version, and command type (internal wired, external wired, or wireless) for all SGD commands. In order to set and get configurations, the noted supported SGD commands can also be used through the serial, parallel, and USB interfaces. Important • All the firmware versions noted in Table 7, refer to minimum firmware version required. Table 7 • SGD Command Syntax Key: Internal Wired = External Wired = Wireless = SGD Commands appl.bootblock appl.name E53.15.0 E53.15.0 card.inserted E53.15.0 card.mac_addr E53.15.0 device.languages E53.15.0 external_wired.ip.arp_interval E53.15.0 E53.15.0 external_wired.ip.default_addr.enable E53.15.0 external_wired.ip.dhcp.cid_all E53.15.0 external_wired.ip.dhcp.cid_enable external_wired.ip.dhcp.cid_prefix E53.15.0 E53.15.0 external_wired.ip.dhcp.cid_suffix E53.15.0 external_wired.ip.dhcp.cid_type E53.15.0 external_wired.ip.gateway E53.15.0 external_wired.ip.netmask E53.15.0 external_wired.ip.port E53.15.0 external_wired.ip.protocol E53.15.0 external_wired.ip.timeout.enable E53.15.0 external_wired.ip.timeout.value E53.15.0 external_wired.mac_addr E53.15.0 internal_wired.ip.addr E53.15.0 internal_wired.ip.arp_interval E53.15.0 internal_wired.ip.default_addr.enable E53.15.0 internal_wired.ip.dhcp.cid_all E53.15.0 internal_wired.ip.dhcp.cid_enable E53.15.0 external_wired.ip.addr 14245L-001 Rev. A S4M / ZM400 / ZM600 EPL Programming Guide 5/30/07 SGD Command Support Printer and Firmware Compatibility Table 7 • SGD Command Syntax Key: Internal Wired = External Wired = Wireless = SGD Commands S4M / ZM400 / ZM600 internal_wired.ip.dhcp.cid_prefix E53.15.0 internal_wired.ip.dhcp.cid_suffix E53.15.0 internal_wired.ip.dhcp.cid_type E53.15.0 internal_wired.ip.gateway E53.15.0 internal_wired.ip.netmask E53.15.0 internal_wired.ip.port E53.15.0 internal_wired.ip.protocol E53.15.0 internal_wired.ip.timeout.enable E53.15.0 internal_wired.ip.timeout.value E53.15.0 internal_wired.mac_addr E53.15.0 ip.active_network E53.15.0 ip.addr ip.arp_interval E53.15.0 ip.bootp.enable E53.15.0 ip.dhcp.cid_all E53.15.0 ip.dhcp.cid_enable E53.15.0 ip.dhcp.cid_prefix E53.15.0 ip.dhcp.cid_suffix E53.15.0 ip.dhcp.cid_type E53.15.0 ip.dhcp.enable E53.15.0 ip.ftp.enable E53.15.0 E53.15.0 ip.http.enable E53.15.0 ip.lpd.enable E53.15.0 ip.gateway E53.15.0 ip.netmask 5/30/07 E53.15.0 ip.pop3.enable E53.15.0 ip.pop3.password E53.15.0 ip.pop3.poll E53.15.0 ip.pop3.server_addr E53.15.0 ip.pop3.username E53.15.0 ip.port E53.15.0 ip.primary_network E53.15.0 EPL Programming Guide 14245L-001 Rev. A 313 314 SGD Command Support Printer and Firmware Compatibility Table 7 • SGD Command Syntax Key: Internal Wired = External Wired = Wireless = SGD Commands 14245L-001 Rev. A S4M / ZM400 / ZM600 ip.smtp.domain E53.15.0 ip.smtp.enable E53.15.0 ip.smtp.server_addr E53.15.0 ip.snmp.enable E53.15.0 ip.snmp.get_community_name E53.15.0 ip.snmp.set_community_name E53.15.0 ip.tcp.enable E53.15.0 ip.telnet.enable E53.15.0 ip.udp.enable E53.15.0 media.printmode E53.15.0 odometer.headclean E53.15.0 odometer.headnew E53.15.0 odometer.label_dot_length E53.15.0 odometer.media_marker_count1 E53.15.0 odometer.media_marker_count2 E53.15.0 odometer.total_print_length E53.15.0 wlan.adhocautomode E53.15.0 wlan.adhocchannel E53.15.0 wlan.associated E53.15.0 wlan.channel_mask E53.15.0 wlan.essid E53.15.0 wlan.firmware_version E53.15.0 wlan.ip.addr E53.15.0 wlan.ip.arp_interval E53.15.0 wlan.ip.default_addr.enable E53.15.0 wlan.ip.dhcp.cid_all E53.15.0 wlan.ip.dhcp.cid_enable E53.15.0 wlan.ip.dhcp.cid_prefix E53.15.0 wlan.ip.dhcp.cid_suffix E53.15.0 wlan.ip.dhcp.cid_type E53.15.0 wlan.ip.gateway E53.15.0 wlan.ip.netmask E53.15.0 EPL Programming Guide 5/30/07 SGD Command Support Printer and Firmware Compatibility Table 7 • SGD Command Syntax Key: Internal Wired = External Wired = Wireless = SGD Commands 5/30/07 S4M / ZM400 / ZM600 wlan.ip.port E53.15.0 wlan.ip.protocol E53.15.0 wlan.ip.timeout.enable E53.15.0 wlan.ip.timeout.value E53.15.0 wlan.keep_alive.enable E53.15.0 wlan.keep_alive.timeout E53.15.0 wlan.kerberos.kdc E53.15.0 wlan.kerberos.password E53.15.0 wlan.kerberos.realm E53.15.0 wlan.kerberos.username E53.15.0 wlan.mac_addr E53.15.0 wlan.operating_mode E53.15.0 wlan.password E53.15.0 wlan.preamble E53.15.0 wlan.private_key_password E53.15.0 wlan.roam.interval E53.15.0 wlan.roam.signal E53.15.0 wlan.security E53.15.0 wlan.signal_noise E53.15.0 wlan.signal_quality E53.15.0 wlan.signal_strength E53.15.0 wlan.station_name E53.15.0 wlan.tx_power E53.15.0 wlan.tx_rate E53.15.0 wlan.username E53.15.0 wlan.wep.auth_type E53.15.0 wlan.wep.index E53.15.0 wlan.wep.key_format E53.15.0 wlan.wep.key1 E53.15.0 wlan.wep.key2 E53.15.0 wlan.wep.key3 E53.15.0 EPL Programming Guide 14245L-001 Rev. A 315 316 SGD Command Support Printer and Firmware Compatibility Table 7 • SGD Command Syntax Key: Internal Wired = External Wired = Wireless = SGD Commands 14245L-001 Rev. A S4M / ZM400 / ZM600 wlan.wep.key4 E53.15.0 wlan.wpa.psk E53.15.0 EPL Programming Guide 5/30/07 B Character References This section has character references. Resident Fonts 1-5 Page Mode supports 5 different font sizes, numbered 1-5. Each font can be expanded both horizontally and vertically. All fonts are non-proportional, mono-spaced. The ASCII value of each character is dependent on the I command character set (code page) selection. Figure 7 • Resident Fonts Example 05/30/2007 EPL Programming Guide 14245L-001 Rev. A 318 Character References Default Character Map Code Page 437 Default Character Map Code Page 437 Fonts 1-4 are represented by the shaded and unshaded cells and Font 5 only supports shaded cells. See the. The electronic manual version on the user's CD includes links to the individual code pages. Figure 8 • Code Page 437 Euro Character Page mode printing supports the Euro character with a character substitution command, the oR command. The Font 5 character set does not support the typical implementation of the Euro character position at 213 decimal (D5 hexadecimal). 14245L-001 Rev. A EPL Programming Guide 05/30/2007 Character References Dump Mode Character Map Dump Mode Character Map The printer’s Dump Mode is used to troubleshoot programming. The printer will print all data as sent in Dump Mode Characters, shown below. Figure 9 • Dump Mode Character Map 05/30/2007 EPL Programming Guide 14245L-001 Rev. A 319 320 Character References Dump Mode Character Map Notes • ___________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ __________________________________________________________________________ 14245L-001 Rev. A EPL Programming Guide 05/30/2007 C 2746e Print Odometer The 2746e printer includes additional hardware for a print odometer to assist with printer maintenance and maintenance scheduling. The print head, as a consumable item, wears out and may need periodic replacement to maintain print quality. The printer also needs regular cleaning and print head conditioning to maximize the service life of the printer and it’s print head. The print odometer can assist with printer maintenance and scheduling. The printer has the ability to report serial number, distance printed by the print head and total distance printed by the printer. The Real Time Clock (RTC) option adds the ability to record the date with the print odometer data. The printer has the ability to report when the properly maintained print head has reached the end its usable life cycle. By default, this feature is disabled and must be activated with EPL2 programming commands. The end of print head life message can also be customized to add service contact information. 05/30/2007 EPL Programming Guide 14245L-001 Rev. A 322 2746e Print Odometer ELP2 Odometer Commands ELP2 Odometer Commands The print odometer data is accessed and controlled via EPL2 Page Mode programming commands. The odometer commands are: URH command - Prints or reports via serial or USB interfaces a print head history report for up to ten print heads. URL command - Prints or reports via serial or USB interfaces the current print head or total print distance of media run on the printer. URR command - Prints or reports via serial or USB interfaces a Print Head Life Reminder status report. The report may include a custom message stored by the oL command, to be displayed when a reminder is issued (default is PRINTHEAD LIFE EXCEEDED), the distance needed to activate print head life reminder (warning) label, and the frequency of reminder labels after the reminder is on and in effect. oL, oLn and oLy commands - Set and control the print head life (exceeded) reminder label’s parameters and reporting status. See the URR command description, above. 14245L-001 Rev. A EPL Programming Guide 05/30/2007 2746e Print Odometer oL oL Print Head Life Reminder Control Description Use this command to customize the print head life reminder report. See the URR command to check the settings and status. Syntax oL[p1,p2,p3] Parameters This table identifies the parameters for this format: Parameters Details No parameters Resets the parameters to their default values for print head life reminder reporting. p1 = Reminder Threshold Sets the distance to be printed before a reminder label warning can be issued. Omitting or setting the value to 0will reset it to the default value of 50 kilometers. Default Value: 50 kilometers Accepted Values: 1–255; 1 = 1 kilometer p2 = Frequency of Reminder Sets the number of labels to be printed prior to issuing another reminder label. Omitting the parameter will reset it to the default. The 0 value causes the printer with the reminder enabled and in effect, to report a Reminder Message at power-up, error recovery, after a media out condition, a reset or after Cancel has been pressed on the printer. Default Value: 0 labels Accepted Values: 1–255; 1 = 1 label printed p3 = Message “DATA” Default Value: PRINTHEAD LIFE EXCEEDED Represents a fixed data field for a message of 39 characters or less. The message “DATA” is bound by quotes. See the EPL2 programming ASCII Text (A) and the Character Set Selection commands for details on printing text. Example • oL40 ; Sets the threshold to 40km, frequency and message are default oL,5 ; Sets the frequency to 5 labels, threshold and message are default oL,,”Replace the print head” ; Sets the message to Replace the print head, threshold and ; frequency are default 05/30/2007 EPL Programming Guide 14245L-001 Rev. A 323 324 2746e Print Odometer oLn oLn Disable Print Head Life Reminder Description Use this command to deactivate the print head life reminder reporting. Use the URR command to check the Print Head Life Reminder settings. Syntax oLn Parameters There are no parameters for this format. 14245L-001 Rev. A EPL Programming Guide 05/30/2007 2746e Print Odometer oLy oLy Enable Print Head Life Reminder Description Use this command to activate the print head life reminder reporting. Use the URR command to check the Print Head Life Reminder settings. Syntax oLy Parameters There are no parameters for this format. 05/30/2007 EPL Programming Guide 14245L-001 Rev. A 325 326 2746e Print Odometer URH URH Print Head History Report Description Use this command to print or report (via the serial or USB interface) a print head history report of the distance printed by the last twenty (20) recorded print heads or the last ten (10) recorded print heads if the RTC is in use. Syntax URH[p1,p2] Parameters This table identifies the parameters for this format. Parameters are optional and maybe entered and any order. Parameters Details p1 = Report Method (device) Sends information back to the host via the serial port and the last active bi-directional interface. p = Printer s = Serial Default Value: s p2 = Units m = Millimeters i = Inches Example • (default) )&"%-*'&)*4503:'034/9999999999 4&3*"-/6.#&3.*4."5$) %*45"/$& 999 999 999<999EBZT> 999 999 999<999EBZT> 999 999 999<999EBZT> 999 999 999 For units with the RTC option installed: The **SERIAL NUMBER MISMATCH ** line prints when the serial number stored in the RTC does not match the serial number stored on the printer’s main PCBA. One or both the PCBA or RTC has been changed in this unit and the odometer data does not accurately represent printer usage. The last print head record does not include the number of days in service. 14245L-001 Rev. A EPL Programming Guide 05/30/2007 2746e Print Odometer URL URL Read Print Odometers Description Use this command to print or report (via the serial or USB interface) latest active print odometer data stored in printer memory. Report printer usage for one or both of the following: • The current distance printed by the presently installed print head. • The total distance printed by the printer. Syntax URL[p1,p2,p3] Parameters This table identifies the parameters for this format. Parameters are optional and maybe entered and any order. Parameters Details No parameters This is the default value. Prints both Head Life and Total Print Distance report data strings. p1 = Report Method (device) Sends information back to the host via the serial port and the last active bi-directional interface. p = Printer s = Serial Default Value: s p2 = Units m = Millimeters i = Inches p3 = Read Meter h = Head Life (distance) t = Total Print Distance Important • Do not use both the p3 parameters, h and t. None = Default. Prints both head Life and Total Print Distance report data strings. Do not use both the p3 parameters, h and t. 05/30/2007 EPL Programming Guide 14245L-001 Rev. A 327 328 2746e Print Odometer URL Example • (default) )&"%VTBHF999 999 999<999EBZT> 505"-VTBHF999 999 999<999EBZT> For units with the RTC option installed: The **SERIAL NUMBER MISMATCH ** line prints when the serial number stored in the RTC does not match the serial number stored on the printer’s main PCBA. One or both the PCBA or RTC has been changed in this unit and the odometer data does not accurately represent printer usage. The last print head record does not include the number of days in service. 14245L-001 Rev. A EPL Programming Guide 05/30/2007 2746e Print Odometer URR URR Print Odometer Status Reporting Description Use this command to print or report (via the serial or USB interface) the status and settings for the print head life reminder label. Syntax URRp1 Parameters This table identifies the parameters for this format. Parameters are optional and maybe entered and any order. Parameters Details p1 = Report Method (device) Sends information back to the host via the serial port and the last active bi-directional interface. p = Printer s = Serial Default Value: s Example 1 • Printout Example for oL Command Default Settings / 05/30/2007 EPL Programming Guide 14245L-001 Rev. A 329 330 2746e Print Odometer URR Example 2 • Activated Print Head Reminder (oLy) and the Parameters Customized : $"--;"4&37*$&1307*%&3 oLy ; Activates Print Head Life Reminder oL40,25,”CALL ZEBRA SERVICE PROVIDER” ; Sets Threshold: 40 kilometers, ; Frequency: 25 labels, ; Message: “CALL ZEBRA SERVICE PROVIDER” URRp 14245L-001 Rev. A ; Prints Print Odometer Status label (see example above) EPL Programming Guide 05/30/2007 Zebra Technologies Corporation 333 Corporate Woods Parkway Vernon Hills, Illinois 60061.3109 U.S.A. Telephone: +1 847 793 2600 Facsimile: +1 847 913 8766 Zebra Technologies Europe Limited Zebra House The Valley Centre, Gordon Road High Wycombe Buckinghamshire HP13 6EQ, UK Telephone: +44 (0) 1494 472872 Facsimile: +44 (0) 1494 450103 Zebra Technologies Asia Pacific, LLC 16 New Industrial Road #05-03 Hudson TechnoCentre Singapore 536204 Telephone: +65 6858 0722 Facsimile: +65 6885 0838 Part Number: 14245L-001 Rev. A © 2007 ZIH Corp.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Annotate, Fill forms, Extract, Print high-res Page Mode : UseOutlines XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2007:05:30 09:51:22Z Creator Tool : FrameMaker 7.2 Modify Date : 2007:05:30 15:15:29-05:00 Metadata Date : 2007:05:30 15:15:29-05:00 Format : application/pdf Title : EPL Programming Guide Creator : Zebra Technologies Corporation Document ID : uuid:73aefcb7-027f-4a73-b8c7-175253f8874c Instance ID : uuid:90c39867-45ad-428c-a1fa-f6a7f001369e Has XFA : No Page Count : 332 Page Layout : SinglePage Author : Zebra Technologies CorporationEXIF Metadata provided by EXIF.tools