Intelligent, Integrated Infrastructure Solution in an Enclosure
SmartCabinet™ is a new approach to providing a complete IT
infrastructure solution that contains power, thermal management,
enclosure, power distribution, monitoring and infrastructure
management all in a simple packaged solution. It is a fully
integrated, industry-leading plug-and-play solution with a ready
to use IT rack space. It eliminates the need to build complex
computer rooms which dramatically improves the speed of system
deployment compared to the traditional approach. SmartCabinet™
is pre-congured, pre-installed, and factory tested to ensure
system compatibility and is ready to use from day one.
Features and Benefits
Fully integrated - factory assembled and
tested for power, thermal management,
rack enclosure, power distribution,
monitoring and management, and security
for IT applications. No dedicated IT room is
required.
Dust protection and noise insulation
Fully closed operation, cold/hot air is
circulated within the rack for better
temperature and humidity control,
expanding lifespan of IT equipment,
low noise level. Highly suitable for ofce
environment.
Highly Efficient - Built-in high efciency
UPS and cooling equipment, that uses
DC frequency conversion technology for
energy savings.
User-friendly interface - Large 7-inch LCD
touch panel that allows for easy access to
system status/alarms/ setting.
Fast deployment – SmartCabinet™
provides faster deployment and is ready
to use from day one, removing the need
to build, construct and design computer
rooms which dramatically reduces the
required deployment period compared to
a traditional IT facility build.
Central Management – optional
feature of RDU-M that provides central
management of SmartCabinet™ at
multiple sites.
Applications:
Branch ofces, retail stores, small &
medium sized business ofces, and
telecommunication sites
Branch locations for government,
educational institutions, healthcare,
nance, business process outsourcing
rms
Warehouse or mobile sites, where
computer/networking room is unavailable
Manufacturing sites for automation
control
SmartCabinet™ Infrastructure Management Solution
34
5
6
1
2
7
8
9
10
Optional: IT Management
Rack Server Access
Provide at-the-rack access to
servers, making software upgrades,
troubleshooting and system
monitoring convenient and less time
consuming.
11
Remote Server and Serial
Management
Providing secure and remote out-of-
band connections to the servers and
serial ports. This unied approach
enables IT administrators a faster
method to diagnose, congure or
restore equipment to meet SLAs and
minimize downtime.
12
Power Management Unit
Built-in Power Management Unit (PMU)
provides MCB to UPS, Cooling unit, PDU, and
bypass. It also provides surge protection to
SmartCabinet™.
2
Power Distribution
Outlet switched Power Distribution Unit (PDU)
distribute power to IT equipment and turn on
emergency fans during power outages.
3
Temperature / Door Access sensors
Temperature sensors at front (cold aisle) and
at rear (hot aisle) report critical environmental
information and alarm users if exceeding
congurable threshold. The door access
sensors at front/rear report alarms on
unauthorized access.
6
UPS and Batteries
5KVA On-line double conversion UPS and battery
cabinet ensures clean power feeding to critical
IT equipment. It also provides backup power to
emergency fans during power outages.
8
Thermal Management (In-Rack Cooling Unit
and Outdoor Condensing Unit)
The thermal unit provides up to 3KW cooling
capacity directly to IT equipment. Since
SmartCabinet™ is fully sealed, the cool air will
only use to cool down critical IT equipment
with the highest efciency. An outdoor unit
is included to eject the heat outdoor. Two
emergency fans automatically run during power
outages ensuring continuous cooling capability.
9
Water Leak Detection
Water leak sensor provides additional
security for critical IT equipment.
10
Touch Panel LCD Display
User-friendly display provide easy access to
information for power, thermal management,
environments, and security
4
Central Management and Monitoring
Provides central management of SmartCabinet™
by monitoring power, thermal, environments,
security, and providing user interface thru touch
panel LCD display.
7
LED Lighting
Low power consumption LED lights that
automatically light up when door is opened.
1
Airow Management
Separate cold air and hot air channels to prevent
hot exhaust air from circulating to the front of
the cabinet.
5
Facility Management
Traditional Room vs. SmartCabinet™
Traditional Room SmartCabinet™
Room preparation Required and complex Not required
Design and construction
Multi-vendor
Time-consuming
Multiple issues
Factory designed and pre-congured
Cost of preparation High Low
Power distribution Requires wall-mounted DB box
Costly
Built-in system
Surge suppression included
Site preparation period 2-3 weeks 1 day
Aesthetic Different design, color, sizes, etc. Integrated design
Area required 10 - 20 sqm 0.7 - 2 sqm
Dust protection Usually not available,
High cost
Fully enclosed system,
IP5X high protection
Noise level Cooling/UPS equipment may go as high as 65dB
Not suitable in ofce environment
Fully enclosed system,
Suitable for ofce environment <50dB
Monitoring system
Individual systems
Low capability
Low integration
Fully Integrated system
Factory Installed / Connected / Tested
User interface Different interfaces for different equipment One integration system for all equipment
Post-sales support Multi-vendors
Poor technical support Single vendor provides full support
Relocation cost High
Difcult
Low
Easy
Pre-assembled Not possible Yes
Pre-connected Not possible Yes
Factory tested Not possible Yes
Large touch panel LCD display provides easy access to
all information about power, thermal management,
environment, alarms, and settings.
Optional: Centralized Management to all
SmartCabinet™ using Rack Data Unit Manager
Interactive Touch LCD Panel
Monitoring Appliance
Site A Site B Site C Site D
IP Network
While every precaution has been taken to ensure accuracy and completeness herein, Emerson Network Power assumes no responsibility, and disclaims all liability, for damages
resulting from use of this information or for any errors or omissions. Specications are subject to change without notice.
Emerson Network Power and the Emerson Network Power Logo are trademarks of Emerson Electric Co. or one of its afliated companies. All other names and logos referred to
are trade names, trademarks, or registered trademarks of their respective owners.
©2016 Emerson Electric Co. All right reserves ANZ16SOLS – SmartCabinetV7-DS
Technical Specifications
Rack Size 2000 mm (42U) x 600 mm x 1200 mm
Useable U space 29U
Air Flow Management Panel 5U x 3, 2U x 3, 1U x 2
Maximum depth of equipment 1023 mm
Vertical Cable Management Panel 2
Area 0.6m x 1.2m = 0.72 m
2
Color RAL7021 Black
IP Marking IP5X
Display panel 7" Touch Panel LCD
Display Languages English / Chinese
LED Lighting 2
System Luminance 88lux/1M
UPS Capacity 5,000VA / 4,500W
UPS Backup time 10 minutes @3000W load
20 minutes @2000W load
System Input Requirement Min. 40A Max. 50A, Single Phase
System Frequency 50Hz or 60Hz (2 different models)
Power Distribution Units (PDU) 32A input Switched PDU, 18x C13 + 6x C19
Lightning Protection /
Surge Suppression Level 3, 20KA
Maintenance Bypass Included
Cooling Capacity 1,800W ~ 3,500W, variable speed
Refrigerant R410A
Emergency fan Two, one at front bottom and one at rear top
System Management (UPS/Cooling/PDU) Yes
Temperature Sensor 2
Water Leak Detection 1 piece, 5 meters long
Door Access Sensor 2
Safety Standards EN 60950-1:2006+A11:2009+A1:2010+A12:
2011+A2:2013
EMC Standards EN 55022:2010 EN 61000-3-11:2000
EN 55024:2010 EN 61000-3-12:2011
Audible Noise < 50dB (excluding outdoor unit)
Shipping Weight 438kg
Net Weight 348kg
Warranty 2 years parts warranty at system level (ANZ)
* Emerson Network Power reserves the rights to amend the specication without prior notice
NSW Office (HQ)
Unit 6, 39 Herbert Street, St. Leonards NSW 2065
Phone: 1300 673 506
Fax: +61 2 9092 5001
VIC Office
Level 8, 492 St Kilda Road, Melbourne VIC 3004
Phone: +61 3 9290 4800
Fax: +61 3 9290 4801
ACT Office
Unit 3, Level 7, 1 Hobart Place, Canberra ACT 2601
Phone: +61 2 9092 5670
QLD Office
Ground Floor, 74 Astor Terrace, Spring Hill QLD 4000
Phone: +61 7 3198 5250
WA Office
Level 3, 1060 Hay Street, West Perth WA 6005
Phone: +61 8 9480 0675
Fax: +61 8 9321 0320
New Zealand Office
Level 2, MasterCard House,
136 Customs Street West, Auckland
Phone: 0800 32 22 55
Fax: +64 9 309 8276
www.distributioncentral.com