FLIR A310 ex

Fully Compliant With ATEX Regulations
Explosive atmospheres need to be protected from ignition sources. Selecting
equipment and protective systems which meet the requirements of the ATEX
Product Regulations or similar regulations is essential.
FLIR A310 ex is an ATEX compliant solution, with a thermal imaging camera
mounted in an enclosure, making it possible to monitor critical and other
valuable assets also in explosive atmospheres. Typical applications for the
A310 ex include process monitoring, quality control, and fire detection in
explosive locations. Because the FLIR A10 ex is rated IP 67, it can be installed
in dusty environments.
The Flame-Proof Enclosure “d” prevents any explosion transmission from the
inside of the enclosure to the outside.

FLIR A310

The thermal imaging camera inside the FLIR A310 ex is a FLIR A310. This
camera is equipped with both measurement and alarm functionalities.
For a more detailed description of the FLIR A310 thermal imaging
camera, ask for FLIR A310 product leaflet or consult FLIR.com.

INTEGRATED CONTROLLER

The integrated controller features several digital I/O channels and sensors for
temperature, humidity and pressure. Among other functions, the I/O channels
enable the user to switch on/off the camera and the heater via remote control.
The access is accomplished through an integrated web interface or
Modbus TCP/IP.
The integrated controller is equipped with two fiber optic and two Ethernet
parts. This enables a flexible network integration in star or ring topologies.
Hot spots in wood chip pile.

HEATER

FLIR A310 ex comes with a heater which effectively prevents fogging and
freezing of the protection window.

VERIFICATION CERTIFICATE
ZELM 12 ATEX 0485 X

The FLIR A310 ex is ATEX-certified. It can be installed in classification zones
1, 2, 21 and 22. The certification comprises the whole system, which includes
the enclosure, as well as all components inside, such as the thermal imaging
camera, heater and integrated controller.
Flare detection

www.flir.com

Technical specifications FLIR A310 ex
General Data
Ambient temperature
range for operation

FLIR A310 ex
–20°C to +40°C (-4°F to 104°F)

Measurement analysis
Spotmeter

10

Protection class

IP67

Area

10 boxes with max./min./average/position

Weight

6.7 kg (without camera and lens)

Isotherm

1 with above/below/interval

Empty volume

5.06 l

Measurement option

External dimensions (without
sun shield)

D = 170 mm, L = 408 mm

Difference temperature

Housing material / Surface

Nickel-plated aluminium / Powder coated

Reference temperature

Manually set or captured from any measurement function

Protection window

Germanium, double-sided AR Coated, externally with
additional hard-carbon layer

Automatic, based on inputs for distance, atmospheric
temperature and relative humidity

Maximum power of the
additional heater

16 W

Atmospheric
transmission correction
Optics
transmission correction

Operating voltage

24 V DC

Emissivity correction

Variable from 0.01 to 1.0

Maximum electric connection
power
Power cable / Power cable
configuration
Length of power cable

60 W
Helukabel 37264 / Pigtail
4 m (13 ft.)

Reflected apparent
temperature correction
External optics/
windows correction
Measurement corrections

Measurement Mask Filter Schedule response: File
sending (ftp), email (SMTP)
Delta temperature between measurement functions or
reference temperature

Automatic, based on signals from internal sensors

Automatic, based on input of reflected temperature
Automatic, based on input of optics/window
transmission and temperature
Global and individual object parameters

4-port switch with 2 × fiber-optic LC 100Base-FX or
2 × RJ45(10/100) up-links, ring-topology support for
reduced cabling effort, 2 × internal temperature sensors,
air humidity and pressure sensor, digital output module
controllable via Modbus TCP/IP or web interface to
enable turning the heater on/off
Multi-mode breakout fiber AT-V(ZN)Y(ZN)Y 4G50/125
OM2

Alarm

Color palettes

Color palettes (BW, BW inv, Iron, Rain)

Length of Ethernet cable

4 m (13 ft.)

Set-up commands

Date/time, Temperature°C/°F

Ethernet, configuration

Pigtail with FC connector

Storage of images

Integrated controller

Ethernet medium

Explosion protection-specific data

Alarm functions
Alarm output

6 automatic alarms on any selected measurement
function, Digital In, Camera temperature, timer
Digital Out, log, store image,
file sending (ftp), email (SMTP), notification

Set-up

Storage media

Built-in memory for image storage

For use in EX zone

1, 2, 21, and 22

File formats

Standard JPEG, 16-bit measurement data included

Ignition protection category

Flame-proof enclosure “d”

Ethernet

Maximum surface
temperature (according to
temperature class T6)
ATEX certification (version
-AXC)
Verification certificate

Ethernet

Control, result and image

Ethernet, type / standard

100 Mbps / IEEE 802.3

EX-Protection Gas: II 2G Ex d IIC T6 Gb, EX-Protection
Dust: II 2D Ex tb IIC T85° Db

Ethernet, configuration

Pigtail with FC-connector (fiber)

ZELM 12 ATEX 0485 X

Ethernet, communication

TCP/IP socket-based FLIR proprietary

Ethernet, video streaming

MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5

Maximum 85°C

Imaging and optical data
IR resolution

320 × 240 pixels

Ethernet, image streaming

16-bit 320 × 240 pixels @ 7-8 Hz - Radiometric

Thermal sensitivity/NETD

< 0.05°C @ +30°C (+86°F) / 50 mK

Ethernet, protocols

Field of view (FOV) /
Focal length

25° × 18.8° with 18 mm (0.7 in.) lens or 45° × 33.8° with
9.66 mm (0.38 in.) lens

Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP,
HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP,
MDNS (Bonjour), uPnP

Shipping information

Minimum focus distance

0.4 m (1.31 ft.)

Spatial resolution (IFOV)

1.36 mrad with 25° lens or 2.59 mrad with 45° lens

Lens identification

Automatic

F-number

1.3

Image frequency

30 Hz

Focus

Automatic or manual (built in motor)

Zoom

1–8× continuous, digital, interpolating zooming on
images

Detector data
Detector type

Focal Plane Array (FPA), uncooled microbolometer

Spectral range

7.5–13 μm

Detector pitch

25 μm

Detector time constant

Typical 12 ms

Measurement
Object temperature range

–20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to
+662°F)

Accuracy

±2°C (±3.6°F) or ±2% of reading

www.flir.com

Infrared camera with lens, in explosion-proof housing, cardboard box, Printed
documentation, User documentation CD-ROM, Utility CD-ROM

FLIR Systems Trading
Belgium BVBA
Luxemburgstraat 2
B-2321 Meer
Belgium
PH: +32 (0) 3 665 51 00
FLIR Systems, Inc.
9 Townsend West
Nashua, NH 06063
USA
PH: +1 603.324.7611
FLIR Systems AB
Antennvägen 6,
PO Box 7376
SE-187 66 Täby
Sweden
PH: +46 (0)8 753 25 00

FLIR Systems Ltd.
920 Sheldon Ct
Burlington, Ontario
L7L 5K6 Canada
PH: +1 800 613 0507
FLIR Systems UK
2 Kings Hill Avenue Kings Hill
West Malling
Kent
ME19 4AQ
United Kingdom
PH: +44 (0)1732 220 011
www.flir.com
flir@flir.com
NASDAQ: FLIR

Equipment described herein may require US Government authorization for export purposes. Diversion
contrary to US law is prohibited. Imagery for illustration purposes only. Specifications are subject to
change without notice. ©2014 FLIR Systems, Inc. All rights reserved. (Created 09/14)



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c014 79.156797, 2014/08/20-09:53:02
Create Date                     : 2015:03:10 18:09:35+01:00
Metadata Date                   : 2015:03:10 18:09:36+01:00
Modify Date                     : 2015:03:10 18:09:36+01:00
Creator Tool                    : Adobe InDesign CC 2014 (Macintosh)
Instance ID                     : uuid:4b1e612c-988d-4c40-986d-9df03ae7c7ff
Original Document ID            : xmp.did:0180117407206811871F8133FAD11AA1
Document ID                     : xmp.id:acb1b359-9a28-4ac7-9e57-43b9b3b42c06
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:1034346c-c919-4699-9d74-84a3ecb3e872
Derived From Document ID        : xmp.did:B8C672D6082068118083E63BB6B0F975
Derived From Original Document ID: xmp.did:0180117407206811871F8133FAD11AA1
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2014 (Macintosh)
History Changed                 : /
History When                    : 2015:03:10 18:09:35+01:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Slug Family                     : Industry
Slug Version                    : 1.001
Slug Outline File Size          : 0
Slug Kerning Checksum           : 0
Slug Foundry                    : --
Slug Font Kind                  : OpenType - PS
Slug Checksum                   : 32203817
Slug Post Script Name           : Industry-Light
Slug Font Sense 12 Checksum     : 32203817
Page Count                      : 2
Creator                         : Adobe InDesign CC 2014 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu