Fluke 438 II Power Quality And Motor Analyzer User Manual
User Manual: Fluke-438-II-Power-Quality-and-Motor-Analyzer-User-Manual
Open the PDF directly: View PDF .
Page Count: 18
Download | ![]() |
Open PDF In Browser | View PDF |
438-II Motor Analyzer Users Manual March 2016 Rev. 1, 10/17 ©2016-2017 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is three years and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country. Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period. To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal condition of operation or handling, including overvoltage failures caused by use outside the product’s specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point). THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. 11/99 Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands Table of Contents Title Page Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 How to Contact Fluke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 In The Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Motor Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Motor Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Unit Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Set Analyzer Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Trend Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Motor Analyzer Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Mechanical Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Electrical Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 View Analyzer Limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Meter Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Trend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Derating Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Voltage Unbalance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Voltage Harmonics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 i 438-II Users Manual ii Introduction The Motor Analyzer is a feature that measures mechanical power, torque, and rpm on direct-on-line asynchronous motors or asynchronous motors driven by a variable speed drive (VSD). It is a standard feature on the Fluke 438-II and available as an optional upgrade for all models in the Fluke 430 Series II (Fluke 430-II/MA Motor Analyzer upgrade). Combined with electrical power and power-quality measurements, the Motor Analyzer feature provides useful information about a motor’s mechanical and electrical operational variables and its efficiency. The feature dynamically measures critical motor variables as the process operates with no need to use additional mechanical sensors or shut down the process. The Motor Analyzer is for three wire, three-phase DELTA measurement configurations. If any other configuration is active, the feature prompts you to go to the SETUP menu to specify a supported configuration: • 3-phase Delta • 3-phase Open Leg • 3-phase IT • 2-Element How to Contact Fluke To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36-FLUKE (1-800-363-5853) • Europe: +31 402-675-200 • Japan: +81-3-6714-3114 • Singapore: +65-6799-5566 • Anywhere in the world: +1-425-446-5500 Or, visit Fluke's website at www.fluke.com. To register your product, visit http://register.fluke.com. To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. 1 438-II Users Manual Safety Information A Warning identifies hazardous conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test. XW Warning To prevent possible electrical shock, fire, or personal injury: • Read all safety information before you use the Product. • Use the Product only as specified, or the protection supplied by the Product can be compromised. • Comply with local and national safety codes. Use personal protective equipment (approved rubber gloves, face protection, and flame-resistant clothes) to prevent shock and arc blast injury where hazardous live conductors are exposed. • Do not use the Product if it is damaged. • Disable the Product if it is damaged. • Do not work alone. See the 434-II/435-II/437-II Users Manual for a complete list of Safety Warnings and explanation of Symbols used on the Product. In The Box The Motor Analyzer Kit includes: • 438 Series II Power Quality and Motor Analyzer (Side Strap, Battery Pack BP290 -28 Wh, and 8 GB SD Wireless SD Memory Card installed) • Decals for Input Sockets (EU & UK, EU, China, UK, US, Canada) • Hang Strap • Alligator Clips (set of 5) • Test Leads, 2.5 m + Color Coding Clips (set of 5) • Power Adapter • Regional Power Cord • Safety Information (Multi-Language) • CD-ROM with Manuals (Multi-Language), PowerLog Software, and USB drivers • USB Interface Cable for PC Connection (USB A-to-mini USB B) • Soft Carry Case C1740 Additional kits are available that include Flexible 6000 A AC Current Probes (set of 4). Contact Fluke for more information about the kits that are available for the Motor Analyzer. 2 Motor Analyzer Motor Measurements Motor Measurements Table 1 is a list of supported motors: Table 1. Motor Configurations Motor type 3-phase asynchronous Motor measurement connection 3-Wire Direct on Line or 3-Wire connected to VSD Motor winding connection WYE or Delta Table 2 is a list of the range and accuracy of the Motor Analyzer-specific functions. See Specifications in the Fluke 430 Series II Users Manual for the specifications of the other functions. Table 2. Motor Analyzer Range and Accuracy Motor Measurement Range Resolution Accuracy Default Limit 0.7 kW to 746 kW 0.1 kW ±3 %[1] 100 % = nominal power[2] 1 hp to 1000 hp 0.1 hp ±3 %[1] 100 % = nominal power[2] 0 Nm to 25 000 Nm 1 Nm ±5 %[1] 100 % = nominal torque[2] 0 lb ft to 18 500 lb ft 0.1 lb ft ±5 %[1] 100 % = nominal torque[2] Direct on Line 000 rpm to 3600 rpm 1 rpm ±3 %[1] 100 % = nominal rpm[2] VSD 500 rpm to 4140 rpm Mechanical Motor Power Torque rpm Efficiency 0 % to 100 % 0.1 % ±3 %[1] NA Unbalance (NEMA MG 1) 0 % to 100 % 0.1 % ±0.15 % 5% Harmonics Voltage Factor (NEMA MG 1) 0 to 0.20 0.01 ±1.5 % 0.15 Unbalance Derating Factor 0.7 to 1.0 0.1 indicative NA Harmonics Derating Factor 0.7 to 1.0 0.1 indicative NA Total Derating Factor 0.5 to 1.0 0.1 indicative NA [1] Add 5% error when selecting Motor design type Other Specification valid for Motor Power >30 % of rated power, when operating at <30 % of rated Motor Power, the mechanical motor power accuracy is ±3 % +0.7 % of rated power and torque accuracy is ±5 % +1.5 % of rated torque. Specification valid at stable operating temperature. Run the motor for at least 1 hour at full load (2-3 hours if the motor is 50 HP or higher) to obtain stable temperature. Motor must be in near steady state mechanical condition. [2] For Direct Online Motors the nominal values are identical to the rated values on the Motor Nameplate. For VSD driven motors the nominal values are based on the actual motor frequency. Notes: • Rated torque is calculated from rated power and rated speed. • Update rate of Motor Measurements is 1x for each second. • Default Trend duration is 1 week. 3 438-II Users Manual Motor Setup The motor nameplate provides information for the measurement algorithm. This information determines the mechanical parameters from the electrical signals that are used for measurements. It is critical that you enter the nameplate settings accurately to obtain accurate readings. To open the Motor Setup screen: 1. Push . The MENU screen opens. 2. Push to change the page view. 3. Use to move through the menu selections and highlight Motor Analyzer. 4. Push to open the Motor Setup screen. Table 3 is a list of the supported motor operating ranges. Table 3. Motor Operating Range Motor Operating range Direct on Line VFD Voltage (pU) 50 Hz motors 0.9 to 1.1 0.7 to 1.2 60 Hz motors 0.9 to 1.1 0.58 to 1.2 0 to 1.7 0 to 1.7 Current (pU) Input Power (pU) 0 to 2.2 0 to 2.2 Frequency 50 Hz or 60 Hz 40 Hz to 70 Hz Voltage Unbalance (%) 0 to 5 0 to 5 Voltage THD (%) 0 to 20 0 to 25 Note pU (per Unit) = Measured value / Rated value Table 4 is a list of the operating ranges for variable speed drives. Table 4. VSD Operating Range Drive Operating range VFD Over/Under Voltage from Nominal V/f Curve (%) -15 to +15 Carrier Frequency (kHz) 2.5 to 20 5. Note The lower limit applies up to rated frequency; above rated frequency the saturation of the V/f curve is accommodated Use to enter the motor nameplate parameters. The Motor Analyzer supports motor designs according to NEMA and IEC design types. See Table 5 and Table 6. If the design type is unknown, select Other. When set to Other, you must consider an additional error of +5 % for the mechanical motor parameters. 4 Motor Analyzer Motor Setup Table 5. Motor Design Type and Characteristics Summary Motor Design NEMA-A NEMA-B NEMA-C NEMA-D NEMA-E IEC-H IEC-N Starting Current High Medium Medium Medium Medium Medium Medium Starting Torque Medium Medium High Very High Medium High Medium Breakdown Torque High Medium High Very High Medium High Medium Table 6. Nameplate Settings and Ranges Required from motor nameplate Range Resolution 746 W to 746 kW 1 W to 1 kW 1 hp to 1000 hp 1 hp Rated Speed Direct on Line VSD 300 rpm to 3600 rpm 800 rpm to 3600 rpm 1 rpm Rated Voltage 50 Hz motors 60 Hz motors 170 V to 1000 V 208 V to 1000 V 1V Rated Current 1 A to 1500 A 0.1 A Rated Frequency 50 Hz or 60 Hz Rated Cos Q (DPF) 0.01 to 1.00 0.01 Rated Service Factor 1.00 to 1.50 0.01 Motor Design Type NEMA-A, NEMA-B, NEMA-C, NEMA-D, NEMA-E, IEC-H, IEC-N, Other Rated Power --- --- Default values are available for the nameplate settings and ranges. Use (UNIT SETUP) to open the setup screen to configure these values. The selection depends on the default motor frequency. Softkeys: Select UNIT SETUP screen Opens the Motor Analyzer Function Preference screen. Select metric or imperial units for the mechanical motor power, torque, and the default motor frequency. Select TREND SETUP screen Adjusts the duration of the automatic trend recording. The default duration is 7 days. Select DEFAULTS for the MOTOR SETUP screen Sets the default values defined in the Function Preferences screen (see UNIT SETUP). The defaults depend on the default motor frequency. START measurements Starts the Motor Analyzer function. See Motor Analyzer Parameters on page 8. 5 438-II Users Manual See Table 7 for a list of the supported VSDs. Table 7. Supported Variable Speed Drives Drive Characteristics Supported Range Drive Output Frequency 41 Hz to 69 Hz Drive Type Voltage Source Inverter only Drive Control Method V/f (Volt over Hertz) only, open loop vector control, closed loop vector control, and drive with and without encoders Unit Setup Use the setup screen to set the analyzer limits and defaults. Softkeys: ANALYZER LIMITS Sets the Analyzer Limits. 50 HZ DEFAULTS Sets the default values for a 50 Hz motor. 60 HZ DEFAULTS Sets the default values for a 60 Hz motor. BACK Goes to the previous screen. Note When you change the 50 Hz or 60 Hz DEFAULTS, go to the Motor Setup screen to activate the new defaults (see page 4). 6 Motor Analyzer Motor Setup Set Analyzer Limits You can adjust the default limit values that show the system performance in various bar graphs. The limits you enter here adjust where the bar graph shows the transition from orange to red. See Motor Analyzer Parameters on page 8 for more information. To change: 1. Use to change a default value. 2. Press to restore the default values. Trend Setup The Trend Setup screen is a simplified version of the normal TIMED START screen. Motor Analyzer has an immediate start mode only and TIMED START is not available. To open the screen, go to Motor Setup screen and press . The top line is information about the available memory space (43X-series II standard feature). You can adjust the duration of the TREND. Default is the global TREND duration as defined in the Function Preferences Trend setup screen. The TREND resolution is fixed at 1s. Softkeys: CHANGE NAME Change the name of the data file (43X-series II standard feature). BACK Go to the MOTOR SETUP screen. 7 438-II Users Manual Motor Analyzer Parameters The MOTOR ANALYZER screen shows the important mechanical and electrical parameters relative to their rated values, industry standards, or the NEMA MG 1-2014 standard. A separate screen is available for the Mechanical Parameters and one for the Electrical Parameters. To open the screen: 1. Go to the MOTOR SETUP screen. 2. Press (START). 3. Use to move between the screens for electrical and mechanical parameters. Mechanical Parameters The Mechanical Parameters screen shows power, torque, and speed at a glance. This screen also shows the efficiency (ratio between electrical power supplied and mechanical power delivered) in %. A colored bar graph indicates the performance of the motor compared to its rating. The actual value for each parameter shows in the appropriate unit, its relative value in % of rated value or standard, and a bar graph that shows the system performance as: • good (green) • adequate (yellow) • poor (orange) • bad (red) Use to move between the screens for electrical and mechanical parameters. The limit values where the bar graph turns from orange to red are set to NEMA and industry standards. To view these limits, press to open the ANALYZER LIMITS menu. Note The default setting for efficiency is not to show a good or bad indication because the motor can operate only at its rated efficiency at nominal load. For expert use, you can customize the limits. See Set Analyzer Limits on page 7. 8 Motor Analyzer Motor Analyzer Parameters Electrical Parameters The second screen is the electrical power and power factor. It shows the voltage unbalance and harmonics voltage factor according to NEMA MG1. Use to move between the screens for electrical and mechanical parameters. Softkeys: View ANALYZER LIMITS screen. Select METER screen. Select DERATING screen. View MOTOR SETUP screen. STOP measurements and save measurement results. View Analyzer Limit The View Analyzer Limit screen has the same information as the Set Analyzer Limits screen but is readonly. The only allowed action is (OK or BACK) to go to the Motor Analyzer screen where the LIMITS screen was activated. To change the information: 1. Go to the MOTOR ANALYZER screen or METER screen. 2. Press to stop the process. 9 438-II Users Manual Meter Screen The METER screen shows all measurements in the Motor Analyzer mode as a table view. Available readings: Motor Power (k)W or hp Torque Nm or lb.ft Note To select between kW or hp and Nm or lb.ft in, see Unit Setup on page 6. Speed rpm Efficiency % Frequency Hz Harmonics (HVF) NEMA no unit Unbalance (%) NEMA % Harmonics Derating Factor (HDF) no unit Unbalance Derating Factor (UDF) no unit Total Derating Factor no unit The other parameters are existing logger parameters in the 430 Series-II: Active Power 10 (k)W Apparent Power (k)VA Reactive Power (k)var Power Factor no unit Cos φ/DPF no unit Harmonic Power (k)VA Unbalance Power (k)VA Voltage (k)V Current (k)A Volt THD%x % Amp THD%x % Unbalance % Motor Analyzer Motor Analyzer Parameters Softkeys: to scroll through the METER screen. Opens the ANALYZER screen. Opens the TREND screen. Opens the MOTOR SETUP screen. STOP measurements and save measurement results. Trend The Trend screen is the standard trend function from the 43X-Series II that shows the recorded measurement data over time. Note The Power Quality EVENT capture function is not available in Motor Analyzer. 11 438-II Users Manual Derating Screen NEMA has guidelines for the application of induction motors to the characteristics of the power system. The NEMA standard MG 1 2014 recommends derating the permissible motor load if Voltage Unbalance or Voltage Harmonics exist in the power system. Note The Derating screen is not available when Variable Speed Drive is set to YES. Voltage Unbalance When the line voltages applied to a polyphase induction motor are not equal, unbalanced currents in the stator windings will result. A small percentage of voltage unbalance will result in a much larger percentage of current unbalance. Consequently, the temperature rise of the motor that operates at a particular load and percentage voltage unbalance is greater than the motor that operates under the same conditions with balanced voltages. Percent voltage unbalance = 100x (maximum voltage deviation from average voltage)/average voltage If the voltages are unbalanced, the permissible motor load should be derated. The following derating curve is recommended by NEMA for motors with normal starting torque and is implemented in the NEMA Derating screen. 12 Motor Analyzer Motor Analyzer Parameters Voltage Harmonics Harmonic currents are introduced when the line voltages applied to the motor include voltage components at frequencies other than the fundamental frequency of the supply (50 Hz or 60 Hz). The temperature of the motor operating at a particular load and per unit voltage harmonic factor will therefore be greater than that for the motor operating under the same conditions with only voltage at the fundamental frequency applied. When a voltage is applied to the motor that consists of components at frequencies other than the fundamental frequency, the rated power of the motor should be derated according to the Derating Factor shown below. The Harmonic Voltage Factor (HVF) is defined as: n = order of odd harmonic, not including those divisible by three Vn = the per-unit magnitude of the voltage at the nth harmonic frequency The total derating is found by multiplying the Derating due to Unbalance and due to Harmonics. To open: 1. Go to the ANALYZER screen. 2. Push . The Derating screen shows the Motor Load (vertical axis) relative to the advised derating due to voltage unbalance or voltage harmonics (horizontal axis). 13 438-II Users Manual The actual load and derating factor is indicated with a cross-hair. The green area indicates a motor that operates within rated limits. The yellow area indicates the permissible Service Factor area (the Service Factor is from the nameplate on the motor and entered in the Motor Setup screen). The red area indicates the overload area for the motor. A ‘persistence’ function that plots the cross-hair center in blue color is automatically enabled and shows the cross-hair position during the complete measurement. The 2nd screen is selected with . This screen shows the readings used to plot the Derating graph. Softkeys: 14 Access METER screen. Access ANALYZER screen. STOP measurements and save measurement results.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2017:11:14 13:19:12Z Creator : FrameMaker 2017 Modify Date : 2017:11:14 13:49:11-08:00 Has XFA : No Language : en Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Format : application/pdf Title : untitled Creator Tool : FrameMaker 2017 Metadata Date : 2017:11:14 13:49:11-08:00 Producer : Acrobat Distiller 17.0 (Windows) Document ID : uuid:57ed29a5-6847-43e5-942b-84717de8e79c Instance ID : uuid:743689d2-7409-4d70-b279-040a5d50ac68 Page Layout : SinglePage Page Mode : UseOutlines Page Count : 18EXIF Metadata provided by EXIF.tools