Getting Started With The NI PCIe 8235 GS_NI_8235 GS

User Manual: GS_NI_8235

Open the PDF directly: View PDF PDF.
Page Count: 10

DownloadGetting Started With The NI PCIe-8235 GS_NI_8235 GS 8235
Open PDF In BrowserView PDF
Getting Started with the NI PCIe-8235
The NI PCIe-8235 (NI 8235) is a quad port Gigabit Ethernet (GigE) interface device for PCI Express
(PCIe) computers. This document describes how to install and configure the necessary hardware and
software components to begin using the NI 8235.

What You Need to Get Started
You need the following items to set up and use the NI 8235.

❑ NI 8235 GigE interface device
❑ GigE Vision Camera
❑ Ethernet cable
❑ Computer running Microsoft Windows Vista/2000/XP with at least one available x4 PCIe slot
Note Visit ni.com/info and enter rdvisionvista for more information about
National Instruments interface device compatibility with Windows Vista.

❑ NI Vision Acquisition Software 8.2.1 or later, which includes the NI-IMAQdx driver software
❑ Optional software for developing applications:
–

NI Vision Builder for Automated Inspection

–

NI Vision Development Module

–

LabVIEW

–

LabWindows™/CVI™

–

Microsoft Visual Basic

Related Documentation
The following documents contain additional information that you may find helpful:
•

NI Vision Acquisition Software Release Notes—Outlines new functionality, system requirements,
installation procedures, and descriptions of the documentation included with the NI-IMAQdx
driver software.

•

Measurement & Automation Explorer Help for NI-IMAQdx—Describes how to configure the
NI-IMAQdx driver software, NI interface devices, and cameras using Measurement & Automation
Explorer (MAX).

•

NI-IMAQdx Help—Contains fundamental programming concepts for the NI-IMAQdx driver
software

Safety Information
Caution

The following paragraphs contain important safety information you must follow when
installing and operating the device.
Do not operate the device in a manner not specified in the documentation. Misuse of the device may
result in a hazard and may compromise the safety protection built into the device. If the device is
damaged, turn it off and do not use it until service-trained personnel can check its safety. If necessary,
return the device to National Instruments for repair.
Keep away from live circuits. Do not remove equipment covers or shields unless you are trained to do
so. If signal wires are connected to the device, hazardous voltages can exist even when the equipment is
turned off. To avoid a shock hazard, do not perform procedures involving cover or shield removal unless
you are qualified to do so. Disconnect all field power prior to removing covers or shields.
If the device is rated for use with hazardous voltages (>30 Vrms, 42.4 Vpk, or 60 Vdc), it may require a
safety earth-ground connection wire. Refer to the device specifications for maximum voltage ratings.
Because of the danger of introducing additional hazards, do not install unauthorized parts or modify
the device. Use the device only with the chassis, modules, accessories, and cables specified in the
installation instructions. All covers and filler panels must be installed while operating the device.
Do not operate the device in an explosive atmosphere or where flammable gases or fumes may be
present. Operate the device only at or below the pollution degree stated in the specifications. Pollution
consists of any foreign matter—solid, liquid, or gas—that may reduce dielectric strength or surface
resistivity. The following is a description of pollution degrees.
•

Pollution Degree 1—No pollution or only dry, nonconductive pollution occurs. The pollution has
no effect.

•

Pollution Degree 2—Normally only nonconductive pollution occurs. Occasionally, nonconductive
pollution becomes conductive because of condensation.

•

Pollution Degree 3—Conductive pollution or dry, nonconductive pollution occurs. Nonconductive
pollution becomes conductive because of condensation.

Clean the device and accessories by brushing off light dust with a soft, nonmetallic brush. Remove other
contaminants with a stiff, nonmetallic brush. The unit must be completely dry and free from
contaminants before returning it to service.
You must insulate signal connections for the maximum voltage for which the device is rated. Do not
exceed the maximum ratings for the device. Remove power from signal lines before connection to or
disconnection from the device.
Caution National Instruments measurement products may be classified as either Measurement
Category I or II. Operate products at or below the Measurement Category level specified in the
hardware specifications.

Getting Started with the NI PCIe-8235

2

ni.com

Measurement Category1: Measurement circuits are subjected to working voltages2 and transient
stresses (overvoltage) from the circuit to which they are connected during measurement or test.
Measurement Category establishes standardized impulse withstand voltage levels that commonly occur
in electrical distribution systems. The following is a description of Measurement (Installation3)
Categories:
•

Measurement Category I is for measurements performed on circuits not directly connected to the
electrical distribution system referred to as MAINS4 voltage. This category is for measurements of
voltages from specially protected secondary circuits. Such voltage measurements include signal
levels, special equipment, limited-energy parts of equipment, circuits powered by regulated
low-voltage sources, and electronics.

•

Measurement Category II is for measurements performed on circuits directly connected to the
electrical distribution system. This category refers to local-level electrical distribution, such as that
provided by a standard wall outlet (e.g., 115 V for U.S. or 230 V for Europe). Examples of
Measurement Category II are measurements performed on household appliances, portable tools,
and similar products.

•

Measurement Category III is for measurements performed in the building installation at the
distribution level. This category refers to measurements on hard-wired equipment such as
equipment in fixed installations, distribution boards, and circuit breakers. Other examples are
wiring, including cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation,
and stationary motors with permanent connections to fixed installations.

•

Measurement Category IV is for measurements performed at the primary electrical supply
installation (<1,000 V). Examples include electricity meters and measurements on primary
overcurrent protection devices and on ripple control units.

Unpacking
The NI 8235 ships in an antistatic package to prevent electrostatic discharge from damaging device
components. To avoid such damage in handling the device, take the following precautions:
1.

Ground yourself using a grounding strap or by touching a grounded object, such as the computer
chassis.

2.

Touch the antistatic package to a metal part of the computer chassis before removing the device
from the package.
Caution

3.

Never touch the exposed pins of connectors.

Remove the device from the package and inspect it for loose components or any other signs of
damage. Notify National Instruments if the device appears damaged in any way. Do not install a
damaged device in the computer.

Store the NI 8235 in the antistatic package when not in use.

1
2
3
4

Measurement Categories as defined in electrical safety standard IEC 61010-1.
Working voltage is the highest rms value of an AC or DC voltage that can occur across any particular insulation.
Measurement Category is also referred to as Installation Category.
MAINS is defined as the (hazardous live) electrical supply system to which equipment is designed to be connected for the
purpose of powering the equipment. Suitably rated measuring circuits may be connected to the MAINS for measuring
purposes.

© National Instruments Corporation

3

Getting Started with the NI PCIe-8235

Installation
The following instructions are for general installation. Refer to the documentation provided by your
computer manufacturer for specific instructions and warnings. Refer to the Specifications section for a
list of the typical power requirements for the NI 8235.
1.

Install the NI Vision Acquisition Software before installing the NI 8235. Refer to the NI Vision
Acquisition Software Release Notes for specific installation instructions.

2.

Power off and unplug the computer.
Caution

To protect yourself and the computer from electrical hazards, the computer must remain
unplugged until the installation is complete.

3.

Remove the computer cover to expose the expansion slots.
Caution Installing a PCIe device into a PCI, PCI-X, AGP, or any non-PCIe slot can damage both the
computer motherboard and the device. If you are unsure of the differences between the connector
types, do not install the device. Refer to the documentation provided by your computer manufacturer
to determine the correct slot in which to install the NI 8235.

4.

Touch a metal part of the computer to discharge any static electricity that might be on your clothes
or body. Static electricity can damage the device.

5.

Choose an unused x4 or larger PCIe slot, and remove the corresponding expansion slot cover on
the back panel of the computer. Figure 1 shows the different types of expansion slots available on
most computers.
Note The NI 8235 is intended for a x4 PCIe slot. The NI 8235 will fit into, and can be used in, a x8
or x16 PCIe slot.

Getting Started with the NI PCIe-8235

4

ni.com

1

2

3

4

1
2

PCI 32-bit Connector
PCI 64-bit and/or PCI-X Connector

3
4

PCIe x4 Connector
PCIe x16 Connector

Figure 1. PC Expansion Slots

6.

Remove your device from the antistatic package and gently rock the device into the slot.
The connection may be tight, but do not force the device into place.
Note Check that the bracket of your device lines up with the hole in the back panel rail of the
computer chassis.

7.

Secure the device mounting bracket to the back panel rail of the computer.

8.

Replace the computer cover.

9.

Connect the Ethernet cable to your camera. Refer to your camera manufacturer documentation for
specific instructions about how to connect the cable to your camera.

10. Connect the Ethernet cable to one of the RJ-45 connectors on the NI 8235 front panel.
11. Plug in and power on the computer.
The NI 8235 is now installed and the camera is connected.

© National Instruments Corporation

5

Getting Started with the NI PCIe-8235

Installing the High Performance GigE Vision Driver
To achieve maximum performance, you must install the High Performance GigE Vision Driver available
with NI-IMAQdx. This will ensure optimized performance and minimal configuration. To associate the
NI 8235 with the high performance driver, complete the following steps.
1.

After you have installed the NI 8235 and restarted the computer, complete one of the following
steps.
a.

If Windows does not prompt you to choose a driver, proceed to step 2.

b.

If Windows prompts you to choose a driver, proceed to step 3.

2.

Right-click the NI 8235 in the Windows Device Manager, and select Update Driver.

3.

Choose not to connect to the Windows Update Web site, and click Next.

4.

Choose to Install from a list or a specific location, and click Next.

5.

Choose Don’t Search. I will choose the driver to install.

6.

Click Next.

7.

Select National Instruments GigE Vision driver from the list, and click Next.

8.

Click Finish.
Note

Windows may return a warning stating that the driver is unsigned. It is safe to ignore the
warning.

Configuring Multiple Ports
Complete the following steps to configure the network ports on the NI 8235:
1.

In the Windows Control Panel, double-click Network Connections.

2.

Select all of the ports that cameras will be connected to by holding  while clicking each port.

3.

Right-click one of the selected ports, and choose Bridge Connections.
Note If you are not using the High Performance Driver, you will be unable to use jumbo frames on
bridged devices.

Configuring GigE Cameras
After you have installed the NI 8235 and powered on your computer, Windows will recognize the device
and assign resources to it. Use Measurement & Automation Explorer (MAX), the National Instruments
configuration utility, to configure a GigE Vision compliant camera, connected to the NI 8235, for
acquisition. Refer to the Measurement and Automation Explorer Help for NI-IMAOdx for more
information about how to configure the NI 8235.

Getting Started with the NI PCIe-8235

6

ni.com

Specifications
The following specifications apply to the NI 8235 interface device. These specifications are typical at
25 °C, unless otherwise stated.

Physical Characteristics
Dimensions ............................................................12.9 cm × 12.0 cm (5.1 in. × 4.725 in.)
Camera Interface....................................................Four RJ-45 connectors
Weight ....................................................................166.5 g (5.87 oz)

Signaling
Ethernet..................................................................1000Base-T compliant on four pairs of
Category 5 cable

Power Requirements
Typical....................................................................1 A at 12 V = 12 W

PCI Express Interface
PCI Express compliance ........................................Version 1.0a
Native link width....................................................x4
Up-plugging link width availability.......................x8, x16

Operating Environment
The NI 8235 is intended for indoor use only.
Ambient temperature range ...................................0 °C to 55 °C
Operating relative humidity ...................................50% to 85%, noncondensing
Pollution Degree ....................................................2
Caution

Do not use the NI 8235 for connection to signals within Measurement Categories II, III,

or IV.
Approved at altitudes up to 2,000 m.

Storage Environment
Ambient temperature range ...................................–40 °C to 70 °C
Relative humidity...................................................50% to 85%, noncondensing

Safety
This product is designed to meet the requirements of the following standards of safety:
•

IEC 60950-1, EN 60950-01

•

UL 60950-1, CSA 60950-1

© National Instruments Corporation

7

Getting Started with the NI PCIe-8235

Electromagnetic Compatibility
This product is designed to meet the requirements of the following standards of EMC for electrical
equipment for measurement, control, and laboratory use:
•

FCC Part 15—Radiated and Conducted Emissions (USA)

•

ICES-003—Radiated and Conducted Emissions (Canada)

•

CISPR 22—Radiated and Conducted Emissions (International)

•

EN55022—Radiated and Conducted Emissions (European Union)

•

EN55024—(Immunity) (European Union)

•

VCCI—Radiated and Conducted Emissions (Japan)

•

CNS13438—Radiated and Conducted Emissions (Taiwan)

•

AS/NZS3548—Radiated and Conducted Emissions (Australia/New Zealand)

•

MIC notice 1997-41, EMI and MIC notice 1997-42—EMS (Korea)

CE Compliance
This product meets the essential requirements of applicable European Directives, as amended for
CE marking, as follows:
•

73/23/EEC; Low-Voltage Directive (safety)

•

89/336/EEC; Electromagnetic Compatibility Directive (EMC)

FCC Class B User Information
This equipment has been tested and found to comply with the limits for the class B digital device
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. The equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in
a particular installation.
If this equipment does cause harmful interference to television or radio reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following means:
•

Reorient or relocate the receiving antenna.

•

Increase the separation between the equipment and receiver.

•

Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.

•

Consult the dealer or an experienced radio/TV technician for help.
Caution If the device is changed or modified, the user may void his or her authority to operate the
equipment.
Note

This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.

Note Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory
compliance information. To obtain the DoC for this product, visit ni.com/certification,
search by model number or product line, and click the appropriate link in the Certification column.

Getting Started with the NI PCIe-8235

8

ni.com

Environmental Management
National Instruments is committed to designing and manufacturing products in an environmentally
responsible manner. NI recognizes that eliminating certain hazardous substances from our products is
beneficial not only to the environment but also to NI customers.
For additional environmental information, refer to the NI and the Environment Web page at
ni.com/environment. This page contains the environmental regulations and directives with which
NI complies, as well as other environmental information not included in this document.

Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling center.

For more information about WEEE recycling centers and National Instruments WEEE initiatives,
visit ni.com/environment/weee.htm.

⬉ᄤֵᙃѻક∵ᶧ᥻ࠊㅵ⧚ࡲ⊩ ˄Ё೑ RoHS˅
Ё೑ᅶ᠋ National Instruments ヺড়Ё೑⬉ᄤֵᙃѻકЁ䰤ࠊՓ⫼ᶤѯ᳝ᆇ⠽䋼ᣛҸ (RoHS)DŽ
݇Ѣ National Instruments Ё೑ RoHS ড়㾘ᗻֵᙃˈ䇋ⱏᔩ ni.com/environment/rohs_chinaDŽ
(For information about China RoHS compliance, go to ni.com/environment/rohs_china.)

Where to Go for Support
The National Instruments Web site is your complete resource for technical support. At ni.com/
support you have access to everything from troubleshooting and application development self-help
resources to email and phone assistance from NI Application Engineers.
A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European
Communities using the manufacturer’s declaration of conformity. This system affords the user
protection for electronic compatibility (EMC) and product safety. You can obtain the DoC for your
product by visiting ni.com/certification. If your product supports calibration, you can obtain the
calibration certificate for your product at ni.com/calibration.
National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin,
Texas, 78759-3504. National Instruments also has offices located around the world to help address
your support needs. For telephone support in the United States, create your service request at
ni.com/support and follow the calling instructions or dial 512 795 8248. For telephone support
outside the United States, contact your local branch office:
Australia 1800 300 800, Austria 43 662 457990-0, Belgium 32 (0) 2 757 0020,
Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 5050 9800,
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00, Finland 358 (0) 9 725 72511,
France 01 57 66 24 24, Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737,
Italy 39 02 41309277, Japan 0120-527196, Korea 82 02 3451 3400, Lebanon 961 (0) 1 33 28 28,
Malaysia 1800 887710, Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466,
New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60, Poland 48 22 3390150,
Portugal 351 210 311 210, Russia 7 495 783 6851, Singapore 1800 226 5886,
Slovenia 386 3 425 42 00, South Africa 27 0 11 805 8197, Spain 34 91 640 0085,
Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151, Taiwan 886 02 2377 2222,
Thailand 662 278 6777, Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545

© National Instruments Corporation

9

Getting Started with the NI PCIe-8235

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms
of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and
company names mentioned herein are trademarks or trade names of their respective companies. For patents covering
National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt
file on your media, or ni.com/patents.
© 2008 National Instruments Corporation. All rights reserved.

372550A-01

Apr08



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Modify, Copy, Annotate, Fill forms, Extract, Print high-res
Page Mode                       : UseOutlines
Signing Date                    : 2008:04:14 11:21:36-05:00
Signing Authority               : ARE_Acrobat Collaboration V7.0 P9 0000109
Annotation Usage Rights         : Create, Delete, Modify, Copy, Import, Export
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Creator Tool                    : FrameMaker 7.2
Modify Date                     : 2008:04:14 11:21:37-05:00
Create Date                     : 1994:04:04 15:32:45Z
Metadata Date                   : 2008:04:14 11:21:37-05:00
Format                          : application/pdf
Title                           : Getting Started with the NI PCIe-8235
Creator                         : Technical Communications
Description                     : 372550A-01, April 2008
Document ID                     : uuid:d90bf2ba-4a25-443e-bca5-16bf5ca75772
Instance ID                     : uuid:0c8801f0-699b-42fc-bb90-a47f4bfcfe28
Has XFA                         : No
Page Count                      : 10
Page Layout                     : SinglePage
Subject                         : 372550A-01, April 2008
Author                          : Technical Communications
EXIF Metadata provided by EXIF.tools

Navigation menu