一 GST104
User Manual: GST104
Open the PDF directly: View PDF .
Page Count: 27
Download | |
Open PDF In Browser | View PDF |
GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution Contents 1 Introduction .............................................................................................................................1 2 Technical Specifications..........................................................................................................1 2.1 2.2 2.3 2.4 2.5 3 Operating Voltage..............................................................................................................1 Standby Batteries ..............................................................................................................1 Parameters of Detection Zones .........................................................................................1 Parameters of Output Loops..............................................................................................1 Physical Dimensions .........................................................................................................1 Structure ..................................................................................................................................2 3.1 Appearance........................................................................................................................2 3.2 Internal Structure...............................................................................................................2 3.3 Connecting Terminals .......................................................................................................3 3.4 Instruction of Operating Panel ..........................................................................................4 3.4.1 Instruction of common state indicators .....................................................................4 3.4.2 Zone state indicators .................................................................................................5 3.4.3 Output status indicators ............................................................................................6 3.5 Instruction of Operating States..........................................................................................6 3.5.1 Normal state ..............................................................................................................6 3.5.2 Fault state .................................................................................................................6 3.5.3 Isolate state ...............................................................................................................7 3.5.4 Fire state ...................................................................................................................7 3.5.5 Output state ...............................................................................................................7 3.5.6 Test state....................................................................................................................7 3.5.7 Internal buzzer instruction ........................................................................................7 3.5.8 Description................................................................................................................7 3.6 Instruction of System Setup ..............................................................................................8 3.6.1 Setting operation levels .............................................................................................8 3.6.2 Sounders and transfer volt-free option......................................................................8 4 Use and Operation Instruction ..............................................................................................9 4.1 Basic Operation.................................................................................................................9 4.1.1 Operation of silencing fault and fire alarm...............................................................9 4.1.2 Day/Night mode instruction ....................................................................................10 4.1.3 Operation of self-testing and clearing fire ..............................................................10 4.1.4 Control the external sounders .................................................................................10 4.2 Set Isolate........................................................................................................................10 Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page I of II GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution 4.3 Set Zone Test...................................................................................................................15 4.4 Configuring Output System ............................................................................................17 4.4.1 Configuring sounder 1 ............................................................................................17 4.4.2 Configuring sounder 2 ............................................................................................17 4.5 Link Setting for Auxiliary Output and Earth Fault Monitoring ......................................17 4.6 Connection Method of Detectors, Manual Call Points and Output Loop .......................18 4.7 Typical Wiring Schematic ...............................................................................................19 4.8 Battery Calculation..........................................................................................................20 5 Problem Maintenance and Disposal ....................................................................................21 Appendix―AEOL P-9907 Operating Instruction......................................................................22 Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page II of II GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution 1 Introduction This control panel is a zone fire control panel developed with a SCM. It can monitor 4 zones, and each zone can be connected with up to 15 conventional fire detectors. It has 2 output points to control audible warning devices, such as sounder-beacons, alarm bells etc. This panel is self-contained with internal standby power supply and space provision for two sealed lead-acid batteries. Its functions are microprocessor controlled, including test and isolate functions, day and night mode operation. It has the functions of normal indication, fault indication, alarm indication and warning of short circuit and open circuit. The panel is easy to install and operate. By a key-switch, it can enable the control function; by a key-switch and an internal switch, it can enable the programming function. 2 Technical Specifications 2.1 Operating Voltage DC24V±15% or AC220V±15% 50Hz/60Hz 2.2 Standby Batteries Configure the battery capacity according to the user’s requirement. Calculate as 4.8. The fully loaded capacity is 7AH (operating for 24 hours in the normal standby state). 2.3 Parameters of Detection Zones Output voltage: DC20—28V Standby current: 2.4mA (when connecting with 15 conventional fire detectors) Alarming fire resistor: 150Ω—1.5KΩ(470Ω in normal state) End resistor: 4.7KΩ or AEOL 2.4 Parameters of Output Loops Sounder output: Output voltage: 20—28V DC Output current: 1A Terminal resistor: 4K7 Auxiliary power supply output:0.5A DC20V—DC28V 2.5 Physical Dimensions 380mm×320mm×95mm Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 1 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution 3 Structure 3.1 Appearance Fig. 3.1 3.2 Internal Structure Description: Fig.3.2.1 ① PSU ② Batteries Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 2 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution ③ Control board ④ Control Enable lock ⑤ Evacuate lock ⑥ DIP switch (See Fig.3.2.2) ⑦ Display board DIP 1 DIP switch(SW1) 2 3 4 5 6 7 8 ON Fig. 3.2.2 3.3 Connecting Terminals Fig. 3.3 EARTH:Earth terminal, connecting to enclosure AUX SUPPLY(+,-) :Auxiliary power terminal ZONE INPUT(1~4):Zone input terminals BAT(+,-) :Battery terminals AC 230V(N, ,L) :AC power terminals SOUNDER OUTPUT(1~2) :Sounder output terminals SOUNDER START(+,-):Sounder startup terminals DAY MODE(+,-) :terminals for setting DAY mode Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 3 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution 3.4 Instruction of Operating Panel 3.4.1 Instruction of common state indicators Fire FIRE Silence Common Fault Zone No. Sounder1 2 1 3 Zone Fault/ISO/Test Common Isolate C.P.U Fault Sounder2 Power Fault Battery Ground In Fault Fault Test Power Day Supply Mode 4 I Select I I Operating Indication Isolate TestDay/Night Enter Reset I O Silence Resound O O Evacuate O Control Enable Complies To EN 54-2 Fig.3.4.1 FIRE— Red common fire indicator. This indicator is illuminated steadily when an alarm condition is detected and remains ON until the fire is cleared. Silence—Yellow common silencing indicator. This indicator is illuminated when the internal buzzer or external sounders are in silenceed condition. Common Fault—Yellow common indicator. This indicator flashes when there is any fault and is illuminated after pressing the Silence pushbutton. Common Isolate—Yellow common isolate indicator. This indicator is illuminated when one or more zones are isolated. C.P.U Fault —Yellow indicator. This indicator flashes when the CPU is in fault condition. It is illuminated when the memory verifies errors. Power Fault—Yellow indictor. This indicator is illuminated in the event of failure on the main power supply. Battery Fault—Yellow indicator. This indicator is illuminated in the event of failure on the batteries. Ground Fault—Yellow indicator. This indicator is illuminated when there is an earth fault. In Test—Yellow indicator. This indicator is illuminated when one or more detection zones are in test condition. Day Mode—Yellow indicator. This indicator is illuminated when the panel is operating in accordance with the requirements of the DAY time operation. Power Supply—Green indicator. This indicator is illuminated when the power supply operates normally. Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 4 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution 3.4.2 Zone state indicators Fire FIRE Silence Common Fault Zone No. Sounder1 2 1 3 4 Sounder2 Zone Fault/ISO/Test Common Isolate C.P.U Fault Power Fault Battery Ground In Fault Fault Test Select Power Day Supply Mode I I I Operating Indication Isolate Test Day/Night Enter Reset I O Silence Resound O O O Control Enable Evacuate Complies To EN 54-2 Fig.3.4.2 Fire— Red indicator per zone. This indicator flashes when the relevant zone is in alarm condition. It is illuminated after pressing the Silence pushbutton. Zone Fault/ISO/Test—Yellow indicator per zone. This indicator flashes when the relevant zone is in fault or test condition. It is illuminated when the relevant zone is isolated. Operation state indicators and pushbuttons Fire FIRE Silence Common Fault Zone No. Sounder1 2 1 3 Zone Fault/ISO/Test Common C.P.U Isolate Fault 4 Sounder2 Power Fault Battery Ground In Fault Fault Test I Isolate Test Day/Night Enter Reset Power Day Supply Mode Select I I Operating Indication Silenc Resound I O O O Evacuate O Control Enable Complies To EN Fig.3.4.3 Isolate indicator—Green indicator. This indicator is illuminated when setting isolate mode. Test indicator— Green indicator. This indicator is illuminated when setting test mode. Select pushbutton—Press this pushbutton to make the panel enter in programming state and selecting operation. Shift pushbutton—Press this pushbutton to change states. Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 5 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution Enter pushbutton—Press this pushbutton to confirm. Reset Pushbutton —Press this pushbutton to cancel or reset the operations. Silence Pushbutton –Press this pushbutton to change the silenced state of the internal buzzer. 3.4.3 Output status indicators Sounder1 Fire FIRE Silence Common Fault Zone No. 2 1 3 Common Isolate C.P.U Fault 4 Sounder2 Zone Fault/ISO/Test Power Fault Battery Ground In Fault Fault Test I Isolate Test Day/Night Enter Reset Power Day Supply Mode Select I I Operating Indication Silence Resound I O O O Evacuate O Control Enable Complies To EN 54-2 Fig.3.4.4 Sounder 1 —Yellow indicator. This indicator is illuminated when sounder circuit 1 is activated. It flashes when sounder circuit 1 is in fault condition. Sounder 2 —Yellow indicator. This indicator is illuminated when sounder circuit 2 is activated. It flashes when sounder circuit 2 is in fault condition. 3.5 Instruction of Operating States 3.5.1 Normal state The panel is in Normal (NIGHT) mode only when the Power Supply indicator is illuminated; it is in DAY mode only when the Power Supply and Day Mode indicators are illuminated. There is no sound output of the buzzer to notify this state. 3.5.2 Fault state 3.5.2.1 When any fault occurs, the Common Fault indicator flashes while it is illuminated after pressing the Silence pushbutton. Zone fault: The Zone Fault/ISO/Test indicator flashes when the relevant zone is in fault condition. Output circuit fault: The output indicator flashes when the relevant output circuit is in fault condition. Main power fault, battery fault and grounding fault: The relevant indicators are illuminated. Day fault: The Day Mode indicator flashes. CPU and memory verification fault: The C.P.U indicator is illuminated denoting a failure of the Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 6 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution memory verification, while flashes denoting a failure of the CPU. 3.5.2.2 The buzzer sounds at 0.5s ON and 4.5s OFF. 3.5.3 Isolate state 3.5.3.1 The Common Isolate is illuminated steadily when one or more zones are isolated. Zone isolate: The Zone Fault/ISO/Test indicator is illuminated steadily the relevant zone is in isolate condition. Isolate of alarm output or fault output: The Alarm Output indicator or Fault Output indicator flashes. 3.5.3.2 The buzzer sounds at 0.5s ON and 9.5s OFF. 3.5.4 Fire state 3.5.4.1 The FIRE indicator is illuminated, the Fire indicator flashes when the relevant zone is in alarm condition while it is illuminated after pressing the Silence pushbutton. The In Test indicator is extinguished. 3.5.4.2 The buzzer sounds at 0.25s ON and 0.25s OFF. 3.5.5 Output state The output indicator is illuminated when there is an output in the relevant output circuit. 3.5.6 Test state 3.5.6.1 The In Test indicator is illuminated and the Zone Fault/ISO/Test flashes when the relevant zone is in test state. The buzzer sounds at 0.5s ON and 9.5s OFF when the detector in the tested zone is not activated. 3.5.6.2 When the detector in the tested zone is activated, the In Test indicator is illuminated, while the sound and light display on the panel are the same as in the fire state. 3.5.7 Internal buzzer instruction The fault state, isolate state and alarm state can exist simultaneously. The internal buzzer sounds according to the priorities. The priorities from the highest to lowest are as follows: Alarm 0 (highest), fault 1, isolate and test 2, normal 3 (lowest). In the condition of alarming or starting sounders, the buzzer sounds at 0.25s ON and 0.25s OFF. In the condition of silencing sounders, the buzzer sounds at 0.5s ON and 9.5s OFF. 3.5.8 Description 3.5.8.1. If an operation is enabled in the low operation level, it is still enabled in the high operation level. 3.5.8.2. In the keyboard operating condition, if the operation level changes or no pushbutton has been pressed after 4 minutes, all the keyboard operations are canceled automatically and the system returns to normal monitoring state. 3.5.8.3. The delay output condition of a zone 3.5.8.3.1 This zone is configured for a delay output mode by programming. 3.5.8.3.2 The panel is in Day mode. 3.5.8.3.3 There is no fire alarm in other zones. 3.5.8.3.4 If this zone is in delay condition while other zone(s) is (are) in alarm condition, this Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 7 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution zone will override the delay condition and sends out an output. 3.5.8.4. Dispose the fault of the memory. When the memory is in fault condition, all the programming contents should be configured again. 3.5.8.5. In this manual, denotes constant illumination state; denotes flashing state; denotes extinguishing state. 3.6 Instruction of System Setup 3.6.1 Setting operation levels 3.6.1.1. There are two keyswitches on the panel. See Fig.3.6.1.1. If you insert the key into Control Enable keyswitch and turn it to O position, the panel is enabled at the operation level 1 and the external sounders are in the non-silenceable condition. In testing condition, the sounders have outputs. I I O Evacuate O Control Enable Fig.3.6.1.1 3.6.1.2. Turn the key in the Control Enable keyswitch to I position (see Fig.3.6.1.2), the panel is enabled at the operation level 2. If the sounders are started by the program automatically, turning the Control Enable keyswitch from O to I position will silence the sounders. In testing condition, the sounders have no outputs. I I O Evacuate O Control Enable Fig.3.6.1.2 3.6.1.3. When the panel’s cover is opened, the panel is enabled at the operation level 3. 3.6.2 Sounders and transfer volt-free option 3.6.2.1. Two sounders can be configured to provide an active output contact, a normally open output contact and a normally closed output contact. 3.6.2.1.1. Case 1: Configure sounder 1 as an active output contact, plug the fuse F2, link the fifth and sixth, the second and third pins of jumper X1 with a short circuit link respectively. Refer to Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 8 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution Fig.3.6.2 for the component position. 3.6.2.1.2. Case 2: Configure sounder 1 as a normally open contact, remove the fuse F2, link the first and second, the fourth and fifth pins of jumper X1 with a short circuit link respectively. Refer to Fig.3.6.2 for the component position. 3.6.2.1.3. Case 3: Configure sounder 1 as a normally closed contact, remove the fuse F2, link the first and second, the third and fourth pins of jumper X1 with a short circuit link respectively. Refer to Fig.3.6.2 for the component position. PSU Fig. 3.6.2 3.6.2.2 Table 1 gives the details mentioned above. Table 1 Output For Normally Closed For Normally Open Remove Fuse Fit Jumper Remove Fuse Fit Jumper Number Links Number Links Sounder 1 F2 X1/ 3&4,1&2 F2 X1/ 5&4,1&2 Sounder 2 F3 X2/ 3&4,1&2 F3 X2/ 5&4,1&2 4 For Active Output Remove Fuse Fit Jumper Number Links X1/ 5&6,2&3 X2/ 5&6,2&3 Use and Operation Instruction 4.1 Basic Operation 4.1.1 Operation of silencing fault and fire alarm 4.1.1.1 To silence fault and fire alarm is not limited by operation levels. 4.1.1.2 In the fault condition, press the Silence pushbutton, the internal buzzer will be muted and the Silence indicator will be illuminated. Press the Silence pushbutton again, the internal buzzer will Resound and the Silence indicator goes out. 4.1.1.3 In the alarm condition, press the Silence pushbutton to confirm the fire signal at first. If Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 9 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution the fire information is confirmed in a zone, the Fire indicator will be illuminated instead of flashing. After all the fire information is confirmed, pressing the Silence pushbutton will change the silencing state of the panel. 4.1.2 Day/Night mode instruction 4.1.2.1 The Day/Night mode can be changed by two ways. 4.1.2.2. Shorting out the Day mode input terminals will force the panel into Night mode. 4.1.2.3. At operation level 2, pressing the Shift pushbutton for 1 second will change the Day/Night mode. When Day mode is selected, the Day Mode indicator will be illuminated. 4.1.2.4. After 18 hours constantly being in Day mode, the panel will switch into Night mode automatically, entering in the common fault condition with the Day Mode indicator flashing. At the operation level 2, pressing the Reset pushbutton will clear the fault. 4.1.3 Operation of self-testing and clearing fire 4.1.3.1 Self-testing and clearing fire are enabled at the operation level 2. 4.1.3.2 Pressing the Reset pushbutton for 1 second will clear the alarm in an alarm condition, and check the sound and indicators, clear fault and testing state in other conditions. 4.1.4 Control the external sounders 4.1.4.1. See Fig.4.1.4.1. Turn the key in the Evacuate keyswitch to I position, the external two sounders will be started. I I O Evacuate O Control Enable Fig. 4.1.4 .1 4.1.4.2. See Fig.4.1.4.2. Turn the key in the Evacuate keyswitch to O position, the external two sounders will be returned to previousstatus. I I O Evacuate O Control Enable Fig.4.1.4 .2 4.2 Set Isolate 4.2.1. Isolate setting is enabled to the 4 detection zones. Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 10 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution 4.2.2. Turn the key in the Control Enable keyswitch to I position and press the Select pushbutton for 1 second, the Isolate indicator flashes. Press the Enter pushbutton, the Isolate indicator is illuminated and the panel enters in the isolate setting state. See Fig.4.2a to Fig.4.2d. I Isolate Press Select for 1s O Select Control Enable Day/Night Enter Fig.4.2b Fig.4.2a Isolate Select Day/Night Enter Press Enter Fig.4.2c Fire FIRE Silence Common Fault Zone No. Sounder1 2 1 3 Zone Fault/ISO/Test Common Isolate C.P.U Fault Sounder2 Power Fault Battery Ground In Fault Fault Test Power Day Supply Mode 4 I Select I I Operating Indication Isolate Test Day/Night Enter Reset I O Silence Resound O O Evacuate O Control Enable Complies To EN 54-2 Fig.4.2d 4.2.3. Press the Select pushbutton to select a zone. Then press the Shift pushbutton to change the isolate state of the selected zone. The Zone Fault /ISO/Test indicator in the selected zone is Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 11 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution illuminated to indicate the isolating state and the Fire indicator in the corresponding zone flashes to indicate the selecting state. E.g., the following operation is to select and set isolate state of zone 4. See Fig.4.2e and Fig.4.2f. 1 Fir Isolate 1 Zone Select Day/Ni Ente 2 3 Zone Fault Press Select 2 Fir 1 Zone 2 3 Zone Fault 3 Fir 1 Zone 2 3 Zone Fault Fig.4.2e 1 Fir Isolate Zone Select Day/Ni 1 2 3 Zone Ente Fault Press Shift 2 3 Fir Zone 1 2 Zone Fault Fig.4. Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 12 of 21 3 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution 4.2.4. Press the Enter pushbutton to exit with saving the setting result. See Fig.4.2g. Fire FIRE Silence Common Fault Zone No. Sounder1 2 1 3 4 Zone Fault/ISO/Test Common Isolate C.P.U Fault Sounder2 Power Fault Battery Ground In Fault Fault Test Select Power Day Supply Mode I Operating Indication Isolate Test Day/Night Enter Reset I I Press Enter Silence Resound I O I I O O O Control Enable Evacuate O O Complies To EN 54-2 ENTER Fire FIRE Silence Common Fault Zone No. Sounder1 2 1 3 Zone Fault/ISO/Test Common Isolate C.P.U Fault Sounder2 Power Fault Battery Ground In Fault Fault Test Power Day Supply Mode 4 I Select I I Operating Indication Isolate Test Day/Night Enter Reset I O Silence Resound O O Evacuate O Control Enable Complies To EN 54-2 Fig. 4.2g Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 13 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution 4.2.5 Press the Reset pushbutton to exit without saving the setting result. See Fig.4.2h. Fire FIRE Silence Common Fault Sounder1 2 1 Zone No. 3 4 Zone Fault/ISO/Test Common Isolate C.P.U Fault Sounder2 Power Fault Battery Ground In Fault Fault Test Press Reset Operating Indication Select Power Day Supply Mode Isolate Test Day/Night Enter I I I O Silence Resound Reset I O O O Control Enable Evacuate RESET Complies To EN 54-2 Fire FIRE Silence Common Fault Zone No. Sounder1 2 1 3 Zone Fault/ISO/Test Common Isolate C.P.U Fault Sounder2 Power Fault Battery Ground In Fault Fault Test Power Day Supply Mode 4 I Select I I Operating Indication Isolate Test Day/Night Enter Reset I O Silence Resound O O Evacuate O Control Enable Complies To EN 54-2 Fig.4.2h Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 14 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution 4.3 Set Zone Test Operate at the operation level 2. 4.3.1 Press the Select pushbutton for 1 second, the Isolate indicator flashes. See Fig.4.2a to Fig.4.2c. 4.3.2 Press the Shift pushbutton once, the Test indicator flashes. Then press the Enter pushbutton, the Test indicator is illuminated and the panel enters in zone test setting state. See Fig.4.3a. Press Shift once Isolate Isolate Day/Night Select Select Enter Fire FIRE Silence Common Fault Zone No. C.P.U Fault Enter 2 1 3 4 Sounder2 Power Fault Battery Ground In Fault Fault Test Power Day Supply Mode Day/Night Sounder1 Zone Fault/ISO/Test Common Isolate Press Enter I Select I I Operating Indication Isolate Test Day/Night Enter Reset I O Silence Resound O O Evacuate O Control Enable Press Select Complies To EN 54-2 Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 15 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution Fig. 4.3a Fire FIRE Silence Common Fault Zone No. Sounder1 2 1 3 4 Zone Fault/ISO/Test Common Isolate C.P.U Fault Sounder2 Power Fault Battery Ground In Fault Fault Test Select Power Day Supply Mode I I I Operating Indication Isolate Test Day/Night Enter Reset O Silence Resound O O O Control Enable Evacuate Press Shift I Complies To EN 54-2 Fig.4.3b Fire FIRE Silence Common Fault Zone No. Sounder1 2 1 3 Zone Fault/ISO/Test Common Isolate C.P.U Fault Sounder2 Power Fault Battery Ground In Fault Fault Test Power Day Supply Mode 4 I Select I I Operating Indication Isolate Test Day/Night Enter Reset I O Silence Resound O O Evacuate O Control Enable Complies To EN 54-2 Fig.4.3c 4.3.3 Press the Select pushbutton to select a zone being tested (e.g. select zone 2 in Fig.4.3b and Fig.4.3c). Press the Shift pushbutton, the testing state of the selected zone will be changed and indicated by the Fire indicator of the corresponding zone, which is extinguished in the normal state and illuminated steadily when testing. The Zone Fault/ISO/Test indicator of the corresponding zone flashes when this zone is selected, indicating the selection state. The operations of confirming and canceling are the same with isolate setting. Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 16 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution 4.3.4 4.4 Configuring Output System DIP switch (SW1) DIP 1 Sounder 1: Relevant zone option 2 3 4 5 6 7 8 ON Sounder 2: Enable delay silencing Sounder 1: Enable delay silencing Sounder 2: Relevant Zone option Fig.4.4 4.4.1 Configuring sounder 1 4.4.1.1 Configure sounder 1 through the DIP switch 1 and 2. 4.4.1.1.1 Move the switch SW1.1 to the ON position, indicating sounder 1 has an output when any detection zone detects fire. 4.4.1.1.2 Move the switch SW1.1 to the OFF position, indicating sounder 1 has an output only when detection zone 1 detects fire. 4.4.1.1.3 Move the switch SW1.2 to the ON position, indicating sounder 1 when activated gives an output instantly and is non-silenceable. 4.4.1.1.4 Move the switch SW1.2 to the OFF position, indicating sounder 1 when activated gives an output with delay and is silenceable. The delay time is 1 minute. 4.4.2 Configuring sounder 2 4.4.2.1 Configure sounder 2 through the DIP switch 3 and 4. 4.4.2.1.1 Move the switch SW1.3 to the ON position, indicating sounder 2 has an output when any detection zone detects fire. 4.4.2.1.2 Move the switch SW1.3 to the OFF position, indicating sounder 2 has an output only when detection zone 2 detects fire. 4.4.2.1.3 Move the switch SW1.4 to the ON position, indicating sounder 2 when activated gives an output instantly and is non-silenceable. 4.4.2.1.4 Move the switch SW1.4 to the OFF position, indicating sounder 2 when activated gives an output with delay and is silenceable. The delay time is 1 minute. 4.5 Link Setting for Auxiliary Output and Earth Fault Monitoring 4.5.1. Link jumper X8 (see Fig.3.6.2 for the component position)─Earth fault monitoring is enabled with link in place and disabled with the link removed. 4.5.2. Link X9 (see Fig.3.6.2 for the component position)─If link the first and second pins, the output is permanent. While link the second and third pins, the output is interrupted for 3 seconds when the fire alarm is being cleared. Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 17 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution 4.6 Connection Method of Detectors, Manual Call Points and Output Loop 4.6.1 Terminals of the panel accept one 0.5 to 2.5mm2 stranded or solid conductor. 4.6.2 To comply with EMC requirements, it is necessary to ensure that screened cables are used throughout. When installing, the cable screen is to be clamped inside the cable gland, which must be fitted to the metal of the back box to ensure a 3600 bond. Each zone circuit can connect with 15 detectors and unlimited number of manual call points. There are two methods of connection. 4.6.3 4.6.3.1 Method 1: In a zone circuit, connect all the manual call points before the detectors and a 4.7K resistor to the last device of the zone circuit. This arrangement is shown as Fig.4.6.3.1. MCP Zone + Input Terms Panel MCP 470R (normal ) 470R (normal ) 4K7 Resi stor - Fig.4.6.3.1 NO DIODE 4.6.3.2 Method 2: In a zone circuit, connect the manual call points anywhere, connect an Active End of Line (AEOL) to the last device of this zone circuit and a diodes in all detector bases. This arrangement is shown as Fig.4.6.3.2. MCP Zone Input Terms 470R (normal ) + A.E.O.L - Panel Fig.4.6.3.2 4.6.4 Output zone circuit connection: All the external sounders or remote devices should be polarized and be connected into the zone circuit terminals according to the polar shown in Fig.4.7. A 4.7K resistor should be connected to the last device of the zone circuit. Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 18 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution 4.7 Typical Wiring Schematic PSU Fig.4.7 SOUNDER OUTPUT:Sounder output WIRED SIMILARLY:Wiring similarly FIELD DEVICES:Detectors ZONE INPUT(1~4):Zone input AEOL:Active End of Line VOLT-FREE CONTACT:Active contact Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 19 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution EMI FILTER:Filter PSU:Power supply unit TO DISPLAY BOARD:Connect to display board BATT:Standby battery terminal 4.8 4.8.1. 4.8.2. Battery Calculation Battery voltage: 24V General Data Table 2 PSU size Maximum current output circuits 2.0A 1A of Internal Battery Size 7AH Standby Load (I1) Table 3 Standby Load in Amps(A) Number Basic 4 zone panel with all 1 detectors fitted Auxiliary equipment Current 0.13 Total 0.13 Total Alarm Load (I2) Standby Load in Amps(A) 4 zones in alarm Sounder outputs Auxiliary equipment output Table 4 Number Current 0.50 Total 0.50 If C denotes minimum capacity of the batteries, T denotes standby time in hours, I1 is the total current of the panel in normal standby state, I2 is the total current in alarm state, the battery capacity can be calculated as follow: C=1.25[(I1×T)+I2] Ah Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 20 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution 5 Problem Maintenance and Disposal Table 5 Indication No indicators indicating on the panel after starting the panel Possible Cause 1. There is +24V output and no +5V output. 2. There is no +24V output and no +5V output. Not indicating power fault and battery fault The integrated circuit N6 on the control board is damaged. Misjudging the conditions of detection zone and output circuit checking state 1. False alarming fire of more than one detection zones 2. False warning fault of more than one detection zones 3. False warning fault of more than one output circuits Unable to save configuring result the The integrated circuit D9 (24LC02) on the Display board is damaged. Action 1. Check the integrated circuit N7-3M03 and its peripheral circuit. 2. Check whether the fuse F7 on the control board has been blown; check the relay K7 on the control board and its peripheral circuit. Remove the damaged IC and replace a good one and check its peripheral circuit. 1. Measure whether the voltage of the test point VREF_H on the control board is normal. Calculate this voltage according to the +24V power voltage (practical measurement) and the resistors R67 and R60. Generally, when the power voltage is 27V, the point voltage is 3.65V. 2. Measure whether the voltage of the test point VREF_L on the control board is normal. Calculate this voltage according to the +24V power voltage (practical measurement) and the resistors R68 and R61. Generally, when the power voltage is 27V, the point voltage is 1.0V. Measure whether the voltage of the test point VREF_S on the control board is normal. Calculate this voltage according to the +24V power voltage (practical measurement) and the resistors R58 and R6. Generally, when the power voltage is 27V, the point voltage is 24.7V. 3. Measure whether the voltage of the test point VREF_H on the control board is normal. Configure the jumpers of X1 and X2 and insert the fuses of F2 and F3 as intended. Remove the damaged IC and replace a good one. Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 21 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution Manual lock or some pushbutton disabled The integrated circuit D1(89C58) Plug D1(89C58)in the socket well. on the display board is not well connected with the socket. Appendix―AEOL P-9907 Operating Instruction 1. Technical Characteristics 1.1 Technical Specifications +4 Operating voltage: DC24 -9 V Nominal voltage: DC24V Equivalent resistor: 4.7kΩ 1.2 Operating Environment Temperature: -10℃—+50℃ Relative humidity: <95%(40℃±2℃) 2. Structure Features 1:Enclosure 2:Fixing bolt 3:Circuit board Fig.1 Bottom view Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 22 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution Fig.2 Top view (without top cover) Connecting terminal 1:VD+ Connecting terminal 2:VD- Connecting terminal 3:- VD+, VD—:connecting to a diode VD+, —: connecting to zone loop 3. Installation and Wiring 3.1 Zone Wiring Fitted detector base Output terms of zone fire MCP Active End of Line (AEOL) + VD+ VD- control ·· panel repeaters or Schottky diode Schottky diode 470Ω(nominal) (Connected by user) (Short-circuited when detector is fitted) Fig.3 Wiring sketch 3.2 Installation and Connection The installation method of an Active End of Line is the same as the detector base, and the AEOL can be used as a base with a conventional detector fitted. By this method, connect the positive poles of both zone loop and a diode to the ‘VD+’ terminal, connect the negative pole of the diode to ‘VD-‘ terminal, and the negative pole of zone loop to the ‘-‘ terminal. Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 23 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution Note: Diodes shouldn’t be connected if there is no detector fitted on the AEOL. In this condition, connect the positive pole of the zone loop to the ‘VD-‘ terminal and the negative pole to the ‘-‘ terminal. Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 24 of 21 GST104 Zone Control Panel Operation Manual Global System Technology PLC The Intelligent Solution GST UNITED KINGDOM Victoria House 60 Westcliffe Road 28-38 Desborough Street Ruskington, High Wycombe Bucks HP11 2NF Sleaford United Kingdom NG34 9AY Tel: +44 (0)1494 601107 Tel: 01526 833999 Fax: +44 (0)1494 601108 Fax: 01526 833011 GST DUBAI Unit ZA04 Jebel Ali Free Zone P O Box 17998 Dubai UAE Tel: +971 (0)4 88 33 050 Fax: +971 (0)4 88 33 053 GST TURKEY Kordonboyu Mahhallesi Ankara Cadessi No. 148/2 Kartal, Istanbul, Turkey Tel: +90 216 353 7344 Fax: +90 216 353 7345 GST EGYPT 53m Yussef Abbs. St, App.63 EL Tawfiek Building Nasr City Cairo Egypt Tel: +202 4030381 Fax: +202 4047949 GST ASIA 80 Changjiang east Road, QETDZ Qinhuangdao, Hebbei, P.R. China.066004 Tel: 00 86 335 8502523 Fax: 00 86 335 8051342 Email Tech.support@gstplc.com Web: www.gstplc.com Global System Technology PLC London EC1A 9RL www.gstplc.com E-mail: tech.support@gstplc.com Page 25 of 21
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 27 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:fa2424c7-7d9f-43be-b68a-48e9093edbbd Producer : Acrobat Distiller 6.0 (Windows) Company : GST Source Modified : D:20030905173710 Headline : Create Date : 2003:09:05 20:37:37+03:00 Creator Tool : Acrobat PDFMaker 6.0 for Word Modify Date : 2003:09:05 20:58:36+03:00 Metadata Date : 2003:09:05 20:58:36+03:00 Document ID : uuid:b49cfff3-5968-47cb-ae55-e5c9c1c0260a Version ID : 4 Format : application/pdf Title : 一 Creator : 迟明华 Subject : Tagged PDF : Yes Author : 迟明华EXIF Metadata provided by EXIF.tools