Nuvair Compressor Catalog HP_Web HP Web

User Manual: HP_Web

Open the PDF directly: View PDF PDF.
Page Count: 48

Nuvair
Compressed Gas Solutions
Rev.09.01.2011
Table of Contents
What is Nitrox?
• Nitrox Membrane Introduction ..........................................................................................1
• Why use the Nuvair™ Membrane System? ......................................................................2
• Membrane System Flow Chart .........................................................................................3
• System Diagram ...............................................................................................................4
• Membrane System Selection Chart ..................................................................................5
• Equivalent Air Depth Table ...............................................................................................6
Nitrox Systems
• Traveler .........................................................................................................................7
• Traveler II ......................................................................................................................8
• Element .........................................................................................................................9
• LP 280/420/560/713 Nitrox Generator ......................................................................... 10
• LP 280/420/560/713 Marine Nitrox Generator ............................................................. 11
• Voyager ...................................................................................................................... 12
• Voyager™ II,III, IV .......................................................................................................... 13
• LP Surface Supply ................................................................................................... 14 -15
• Quincy 390 > Nuvair 26 D ............................................................................................. 16
• Quincy 390 > Nuvair 26 E ............................................................................................. 17
• Element™ 10-25 hp .................................................................................................. 18 -19
• HP Element™ 10-20 hp ............................................................................................20-21
Low Pressure Compressors
• Information Page ...........................................................................................................22
High Pressure Compressors
• Coltri/Nuvair Portable .....................................................................................................23
• Coltri/Nuvair Compact Portable ......................................................................................24
• Coltri/Nuvair Standard Electric .......................................................................................25
• Coltri/Nuvair Mini Tech ...................................................................................................26
• Coltri/Nuvair 250............................................................................................................ 2 7
• Coltri/Nuvair Compact (Models 7 and 9) .......................................................................28
• Coltri/Nuvair Compact (Models 14 and 18) .................................................................... 2 9
• Coltri/ Nuvair Mini Silent .................................................................................................30
• Coltri/Nuvair Super Silent EVO ....................................................................................... 3 1
• Coltri/Nuvair 26 Open .....................................................................................................32
• Coltri/Nuvair 26 Enclosed Silenced ............................................................................... 3 3
Fill Containment Station
• Information Page ...........................................................................................................34
Gas Analyzers
• O2 Quickstick ............................................................................................................. 3 5
• Pro O2 ....................................................................................................................... 3 6
• Nuvair Pro He............................................................................................................ 3 7
• Pro Trimix .................................................................................................................. 3 8
• Nuvair Pro CO ........................................................................................................... 3 9
• Nuvair Pro CO2 ......................................................................................................... 4 0
Compressor Oil
• Nuvair™ 455 Compressor Oil ........................................................................................ 4 1
• Nuvair™ 541 Compressor Oil ........................................................................................ 41
• Nuvair™ 751 Compressor Oil ....................................................................................... 4 2
• Nuvair™ 800 Compressor Oil ....................................................................................... 4 2
About Us
Nuvair has been manufacturing low and high pressure breathing air systems for the working diver for
over 20 years. In recent years Nuvair has expanded beyond diving into the Fire & Safety, Industrial
and Paintball compressor markets as well. We offer standard and custom congurations for a wide
variety of stationary and portable installations. Nuvair can create customized compressors to meet
your specic needs and guide you through the many congurations that the compressor packages
can be purchased in. Our staff understands that needs, budget and comfort level lead to the choices
one makes on the type, brand and model of compressor you will be using. Nuvair offers custom
congurations of tried and true compressor brands combined with electric, gas or diesel motors of
the same caliber.
All Nuvair compressor packages are manufactured in-house and tested before leaving Nuvair. From
start to nish our technicians are making sure your compressor package is inspected, tested and
delivered on time.
The Company’s CEO and founder, Glenn Huebner, is the innovative force behind many of the
Company’s Nitrox Systems. He has a Bachelors of Science Degree in Finance from California State
University, Northridge and over 25 years experience in commercial and sport diving and the use of
gas producing systems.
The Company’s Production Manager, Danny Graham, assists in the technical design of the
Company’s products and is responsible for coordinating the manufacturing process. He is a certied
compressor repair technician and has over 15 years experience in the commercial and sport diving
industry.
Nitrox Solutions Analyzers Compressors
Panels and Fill Stations Compressor Accessories Fill Containment Stations
Nitrox Systems 1
Nitrox Membrane Systems
Nuvair designs and builds electric, gas, diesel and hydraulic powered Nitrox Membrane Systems for
commercial, sport, live aboard, and government agencies all around the world. Our customers use
Nitrox to increase safety, bottom time, productivity, and prot. The Nuvair Membrane System is more
efcient and easier to use than competing systems.
Nuvair Nitrox Systems use Semi-Permeable Membranes to separate out a portion of the nitrogen in
air. Nitrox mixtures, containing between 21 and 40% oxygen (O2), are then delivered to a High Pressure
Compressor to ll Scuba Cylinders or Storage Tanks or to a Low Pressure Compressor for pumping to
surface-supply divers. Although this Compressor is described as a Nitrox Compressor, it can also be
used to produce air.
The Membrane System requires a source of clean, pressurized, and heated air for separation. The
two most common sources are an LP Compressor (LP Supply) or HP Air Storage Tanks (HP Supply).
The air must be properly ltered to CGA Grade D or E air quality prior to entering the Membrane System
so it will not damage or plug the Membrane bers.
Standard systems are rated for maximum supply pressures of 250 P.S.I. (17 bar) for LP Supply and
5000 P.S.I. (345 bar) for HP Supply; higher ratings are available upon request. An Input Pressure
Regulator reduces these pressures to acceptable levels for the Membrane. The air is then heated to a
temperature that provides stability over a wide range of ambient conditions and is optimal for membrane
permeation.
The heated air enters the Membrane, which is made up of thousands of miniature hollow bers.
The walls of these bers are semi-permeable and designed for different gases to move through them
(or permeate) at different speeds. The resulting gas mixture is known as the permeate. As air ows
through the hollow bers, both oxygen and nitrogen permeate through the ber walls. The oxygen
permeates faster than the nitrogen, which produces permeate with an oxygen content greater than air.
The gas that reaches the end of the hollow bers without permeating is almost entirely nitrogen and is
discharged. The ow rate of this discharge is set by the factory via a xed orice to allow the Membrane
to operate at maximum volume and efciency. The resulting permeate contains approximately 44% O2
and is constant under all operating conditions.
The permeate is a concentrated mixture that must be diluted with additional air prior to entering the
Nitrox Compressor. It exits the Membrane at ambient to slightly negative pressure and travels into the
Mixing Tube, where it mixes homogeneously with ltered outside air. The amount of dilution, and thus
nal %O2, is obtained by adjusting the Input Pressure Regulator. As pressure is increased, permeate
ow increases, air ow decreases, and a higher %O2 Nitrox is produced. As pressure is decreased,
permeate ow decreases, air ow increases, and a lower %O2 Nitrox is produced. This relationship
between permeate ow and air ow exists because the total of these two ow rates will always equal
the intake ow rate demanded by the Nitrox Compressor. The resulting Nitrox mixture is analyzed for
approximate %O2 before entering the Nitrox Compressor and again prior to use for precise %O2.
A unique feature of the Nuvair Nitrox Membrane System is that the input pressure that correlates to a
specic Nitrox %O2 is repeatable. If Nitrox with 36% O2 is produced when the input pressure is at 125
P.S.I. (9 bar), then adjusting the Regulator to 125 P.S.I. (9 bar) during the next use will produce the same
mixture.
2 What is Nitrox?
Why use the NUVAIR™ Membrane System?
Simple
Complete Turnkey operation
Easiest, most stable system available
Adjust regulated input for desired O2%
Only 1 hour operator training required
2 hour average installation
No compressor modications
Reliable
Mix accurate to one tenth of 1%
20-30 year Membrane life
Limited 3 year Membrane warranty
Versatile
Pump Nitrox from 21% to 40% O2
Unlimited continuous on-site production
Low pressure or high pressure supply
No size or ow limits
Banked, hot lls, or continuous output
Ideal for remote sites and live aboard
Compact and lightweight
Trimix systems available
Practical
Replaces Partial Pressure or Continuous
Blending
No O2 cleaning of tanks or equipment
No blending courses required
No high pressure oxygen on site
No expensive blending panels or OCA lters
No worries about voiding compressor warranty
No worries about Fire Inspector shut down
Cost Effective
Up to 20% more efcient than other Membrane
Systems
No oxygen or tank rental costs
High volume output means no waiting for lls
Easy maintenance
Operates on Grade D or E Air
Use your existing oil lubricated compressor
(some compressors may not be suitable)
No hidden costs
Nuvair Membrane System
Inline O2 Sensor
Air Intake
Nitrogen Discharge
Safety Pressure
Switches (2)
Gas Mixing Tube Membrane
Heater
Low Pressure Air Filtration
Air input HP/LP or
LP/LP Regulator with
pressure gauge-
Adjust O2% Here
Connect to LP Grade
E or D Air Supply
Supply Air
On/Off Valve
Thermostat Control
and Temperature
Gauge
Inline O2 Analyzer
Electrical
Connection
110/220 V
50/60 Hz
What is Nitrox? 3
HP Aftercooler Removes
Moisture
HP Air Filtration Produces
Grade E Air
HP Air Storage Tanks Deliver
Supply Air
HP Supply Three Way Valve
Routes Air In/Out of Tanks
HP Supply On/Off Flow Valve
Controls Supply Air
HP>LP Regulator Reduces
Pressure
Backup Oil Vapor Filter for
Redundancy
LP Air Compressor Produces LP
Supply Air
LP Aftercooler Removes Moisture
LP Volume Tank Collects Moisture
and Delivers Supply Air
LP Supply On/Off Flow Valve
Controls Supply Air
LP Air Filtration Produces Grade
D Air (supplied separately)
LP>LP Regulator Reduces
Pressure
Thermostat Controlled Heater
Heats Air to 110ºF (43ºC)
Membrane Separates Supply Air
Into Permeate and Nitrogen Rich
Gas
Permeate Exits Membrane
Containing 44% O2
Optional Vacuum Pump or
Blower
Mixing Tube Mixes Air and
Permeate to Create Nitrox
Inline O2 Analyzer Monitors
Nitrox Before Compression to
+/- 2% O2
Air Intake Delivers Filtered
Ambient Air to Mixing Tube
Fill O2 Analyzer Monitors Nitrox
Mixture to +/- 1% O2
LP Nitrox Delivered to Surface
Supply Diver
HP or LP Nitrox Compressor
with Moisture Removal and
Filtration Compresses Nitrox
Nitrogen Rich Gas Exit Through
Fixed Orice
HP Air Compressor Produces
HP Supply Air
High Pressure Supply Option -------------------- OR ---------------------- Low Pressure Supply Option
HP Nitrox Delivered to Storage
- OR
HP Nitrox Delivered to
Scuba Cylinder
- OR
Membrane
System
Components
Membrane System Flow Chart
4 What is Nitrox?
System Diagram
What is Nitrox? 5
Membrane Model Nuvair 6 CFM Nuvair 10 CFM Nuvair 16 CFM Nuvair 20 CFM Nuvair 32 CFM Nuvair 50 CFM
Physical Specications
Length 44 in
1118 mm
46 in
1168 mm
66 in
1676 mm
46 in
1168 mm
66 in
1676 mm
66 in
1676 mm
Height 30 in
762 mm
32 in
813 mm
32 in
813 mm
38 in
965 mm
38 in
965 mm
45 in
1143 mm
Depth 6 in
152 mm
6 in
152 mm
6 in
152 mm
6 in
152 mm
6 in
152 mm
6 in
152 mm
Shipping
Weight
39 lb.
18 kg
44 lb.
20 kg
50 lb.
23 kg
58 lb.
27 kg
70 lb.
32 kg
90 lb.
41 kg
Temperature
Requirements
Heater
Electrical
Specication
7 A @ 110 VAC,
5 A @ 220 VAC,
50 or 60 Hz
7 A @ 110 VAC,
5 A @ 220 VAC,
50 or 60 Hz
10 A @ 220
VAC, 50 or 60 Hz
10 A @ 220 VAC,
50 or 60 Hz
10 A @ 220 VAC,
50 or 60 Hz
10 A @ 220 VAC,
50 or 60 Hz
Membrane
Temperature
110 +/-5oF
43 +/- 3oC
110 +/-5oF
43 +/- 3oC
110 +/-5oF
43 +/- 3oC
110 +/-5oF
43 +/- 3oC
110 +/-5oF
43 +/- 3oC
110 +/-5oF
43 +/- 3oC
Input
Operating
Pressure
80-170 psi
6-12 bar
80-170 psi
6-12 bar
80-170 psi
6-12 bar
80-170 psi
6-12 bar
80-170 psi
6-12 bar
80-170 psi
6-12 bar
Maximum Input
Pressure
300 psi
(21 bar)
300 psi
(21 bar)
300 psi
(21 bar)
300 psi
(21 bar)
300 psi
(21 bar)
300 psi
(21 bar)
Supply Air
Volume Range
4-15 SCFM
106-425 L/min.
8-25 SCFM
212-708 L/min.
13-40 SCFM
354-1133 L/min.
20-50 SCFM
566-1416 L/min.
25-80 SCFM
708-2266 L/min.
40-125 SCFM
1133-3540 L/min.
LP / HP Supply
Air Quality
LP - Grade D
HP - Grade E
LP - Grade D
HP - Grade E
LP - Grade D
HP - Grade E
LP - Grade D
HP - Grade E
LP - Grade D
HP - Grade E
LP - Grade D
HP - Grade E
Out-
put
Nitrox O2%
Range 21-40% 21-40% 21-40% 21-40% 21-40% 21-40%
Compressor Recommendations
LP Air Supply Compressor
Delivery @175
PSI for 40% O2
9-18 SCFM
255-510 L/min.
18-30 SCFM
510-850 L/min.
30-48 SCFM
850-1359 L/min.
48-60 SCFM
1359-1699 L/min.
60-96 SCFM
1699-2719 L/min.
96-150 SCFM
2719-4248 L/min.
Horsepower -
Electric
3-7.5 hp
2.3-5.6 kW
7.5-10 hp
5.6-7.5 kW
10-15 hp
7.5-11 kW
15-20 hp
11-15 kW
20-30 hp
15-23 kW
40-50 hp
30-38 kW
Horsepower -
Gas
5.5-9 hp
4.1-6.8 kW
11-13 hp
8.3-10 kW
20-24 hp
15-18 kW N/A N/A N/A
Horsepower -
Diesel
5.5-9 hp
4.1-6.8 kW
10 hp
7.5 kW
27 hp
20 kW
27 hp
20 kW
40-50 hp
30-41 kW
54-75 hp
41-56 kW
HP Nitrox
Compressor
Charging Rate 3-6 SCFM
85-170 L/min..
6-10 SCFM
170-283 L/min.
10-16 SCFM
283-453 L/min.
16-20 SCFM
453-566 L/min.
20-32 SCFM
566-906 L/min.
32-50 SCFM
906-1416 L/min.
Horsepower -
Electric
3-5 hp
2.3-3.8 kW
5-7.5 hp
3.8-5.6 kW
10-15 hp
7.5-11 kW
15-20 hp
11-15 kW
20-25 hp
15-19 kW
25-40 hp
19-30 kW
Horsepower -
Gas
5.5-6.5 hp
4.1-4.9 kW
6.5-11 hp
4.9-8.3 kW
13-18 hp
10-14 kW
20-24 hp
15-16 kW N/A N/A
Horsepower -
Diesel
6-6.7 hp
4.5-5.0 kW
9-10 hp
6.8-7.5 kW
11-18 hp
8.3-14 kW
18-27 hp
14-20 kW
27-35 hp
20-26 kW
35-50 hp
26-38 kW
LP Nitrox Compressor
Delivery @175
PSI N/A N/A 10-16 SCFM
283-453 L/min.
16-20 SCFM
453-566 L/min.
20-32 SCFM
566-906 L/min.
32-50 SCFM
906-1416 L/min.
Horsepower -
Electric N/A N/A 5 hp
3.8 kW
7.5 hp
5.6 kW
7.5-10 hp
5.6-7.5 kW
10-15 hp
7.5-11 kW
Horsepower -
Gas N/A N/A 9 hp
6.8 kW
11-13 hp
8.3-10 kW
13-18 hp
10-14 kW
20-24 hp
15-18 kW
Horsepower -
Diesel N/A N/A 9 hp
6.8 kW
10 hp
7.5 kW
27 hp
20 kW
27 hp
20 kW
Membrane System Selection Chart
6 What is Nitrox?
ACTUAL
DEPTH
40
45
50
55
60
65
70
70
75
75
80
80
85
85
90
90
95
95
100
100
105
105
110
110
115
115
120
120
125
130
FO2
36%
37%
37%
39%
40%
40%
40%
38%
40%
36%
40%
35%
39%
33%
37%
34%
36%
31%
34%
33%
33%
30%
32%
30%
31%
30%
30%
27%
29%
26%
EAD
2 6 .14
29.20
3 3 .19
34.95
3 7. 6 3
41. 43
45.23
47. 8 4
49.03
54.49
52.82
59.97
5 8 .11
6 7. 0 8
65.09
69.76
70.70
78.80
7 8 .11
79.80
84.04
89.28
90.09
93.71
96.27
9 8 .14
102.57
108.38
109.00
119 .6 8
PPO2
0.80
0.87
0.93
1.04
1.13
1.19
1.25
1.19
1.31
1.18
1.37
1.20
1.39
1.18
1.38
1.27
1.40
1.20
1.37
1.33
1.38
1.25
1.39
1.30
1.39
1.35
1.39
1.25
1.39
1.28
O2
LIMITS
450
360
300
240
210
210
180
210
150
210
150
210
150
210
150
180
150
210
150
150
150
180
150
180
150
150
150
180
150
180
Nitrox
BOTTOM
TIME
NO LIMIT
NO LIMIT
310
310
200
100
100
100
100
60
60
60
60
50
50
50
40
40
40
40
30
30
25
25
25
25
20
20
20
15
NAVY AIR
BOTTOM
TIME
200
100
100
60
60
50
50
50
40
40
40
40
30
30
30
30
25
25
25
25
20
20
20
20
15
15
15
15
10
10
% TIME
INCREASED
-
-
210%
417%
233%
100%
100%
100%
150%
50%
50%
50%
100%
67%
67%
67%
60%
60%
60%
60%
50%
50%
25%
25%
67%
67%
33%
33%
100%
50%
This is a not to be used as a Dive Table. Please refer to published Dive Tables.
FO2 = Oxygen Fraction
EAD = Equivalent Air Depth
PPO2= Partial Pressure of Oxygen
EAD Table
Nitrox Systems 7
Traveler
Nitrox Traveler Model (Part#7051HP or 7051LP)
Physical Specications
Height
Width
Depth
Weight
22 in (56 cm)
51 in (130 cm)
16 in (41 cm)
134-140 lbs (61-64 kg)
Full Load Amps
230 V - E3 - 50 or 60 Hz
230 V - E1 - 50 or 60 Hz
115 V - E1 - 50 or 60 Hz
11 A
14-19 A
28 A
Membrane Input
Operating Pressure
Supply Air Volume
Optimum Temperature
90-165 psi (6-11 bar)
4-11 SCFM (113-312 L/min.)
110 +/- 5oF (43 +/- 3oC)
HP Nitrox Compressor
Charging Rate
Fill Time(80 Cu.. Ft.)
Horsepower - Electric
Horsepower - Gas
3.4-4.2 SCFM (95-119 L/min.)
20-25 minutes
3-4 hp (2.2-3 kW)
5.5 hp (4 kW)
8 Nitrox Systems
*Single 80 Cu.. Ft. cylinder from 500 - 3000 psi
Traveler II
Nitrox Traveler II Model Gas (Part# 7052G) Electric (Part# 7052E)
Physical Specications
Height
Width
Depth
Weight
48 in (122 cm)
51 in (130 cm)
20 in (51 cm)
385 lbs (175 kg)
48 in (122 cm)
51 in (130 cm)
20 in (51 cm)
410 lbs (186 kg)
LP Compressor Capacity @ 175 psi 12 CFM (340 L/min.) 12 CFM (340 L/min.)
Volume Tank Capacity 15 gal (57L) 15 gal (57L)
Membrane Input
Operating Pressure
Supply Air Volume
Optimum Temperature
90-165 psi (6-11 bar)
4-12 CFM (113-340 L/min.)
110 +/- 5° F (43 +/-3° C)
90-165 psi (6-11 bar)
4-12 CFM (113-340 L/min.)
110 +/- 5° F (43 +/-3° C)
HP Nitrox Compressor
Output
Charging Rate
Fill Time (80 Cu.. Ft.)
Horsepower - Electric
Horsepower - Gas
3.5 CFM, F.A.D. (100 L/min.)
4.2 SCFM*
22 minutes*
7.5 hp (5.5 kW)
11 hp (8.2 kW)
3.5 CFM, F.A.D. (100 L/min.)
4.2 SCFM*
22 minutes*
7.5 hp (5.5 kW)
11 hp (8.2 kW)
This complete turn key Nitrox System is built for the diver that wants to ll tanks while away from Dive Shops.
With this system you can easily ll Nitrox or air while on remote locations (home, vacations or offshore).
Pictured with Optional Wheels
and electric motor.
Nitrox Systems 9
Element HP or LP
Element Nitrox Model Element HP Element LP
Physical
Specications
Height
Width
Depth
Weight
31 in (79 cm)
44 in (112 cm)
23 in (58 cm)
352-450 lbs (160-177 kg)
44 in (112 cm)
44 in (112 cm)
23 in (58 cm)
400-510 lbs (182-232 kg)
Full Load Amps 230 V - E3 - 50 or 60 Hz
230 V - E1 - 50 or 60 Hz
25 A
39 A
25 A
39 A
LP Compressor Capacity @ 175 psi Requires 23 CFM Supply Air 23 CFM (665 L/min.)
Membrane Input
Operating Pressure
Supply Air Volume
Optimum Temperature
90-165 psi (6-11 bar)
13-25 SCFM (354-708 L/min.)
110 +/- 5° F (43 +/-3° C)
90-165 psi (6-11 bar)
8-25 SCFM (212-708 L/min.)
110 +/- 5° F (43 +/-3° C)
HP Nitrox
Compressor
Charging Rate
Horsepower - Electric
Horsepower - Gas
Horsepower - Diesel
9 SCFM (265 L/min.)*
7.5 hp (5.5 kW)
9-11 hp (6.6-8.3 kW)
9 hp (6.6 kW)
6-10 SCFM (170-283 L/min.)*
5-7.5 hp (3.8-5.5 kW)
11-13 hp (8.3-9.7 kW)
9-10 hp (6.6-7.5 kW)
*Single 80 Cu.. Ft. cylinder from 500 - 3000 psi Specications vary depending on motor or engine used to drive compressor.
10 Nitrox Systems
LP 280/420/560/713 Nitrox Generator
Nitrox Generator Model LP 280 LP 420 LP 560 LP 713
Part Number 7060** 7061** 7062** 7063**
Physical
Specications*
Height
Width
Depth
Weight
Horsepower
48 in (122 cm)
59 in (150 cm)
30 in (76 cm)
635 lbs (288 kg)
10 hp (7.5 kW)
76 in (193 cm)
52 in (132 cm)
34 in (86 cm)
872 lbs (396 kg)
15 hp (11.2 kW)
49 in (125 cm)
52 in (132 cm)
34 in (86 cm)
895 lbs (406 kg)
20 hp (15 kW)
74 in (188 cm)
61 in (155 cm)
42 in (107 cm)
1260 lbs (572 kg)
25 hp (18.6 kW)
Full
Load
Amps
440 V - E3 - 50 or 60 Hz
380 V - E3 - 50 or 60 Hz
230 V - E3 - 50 or 60 Hz
16 A
19 A
30 A
21 A
24 A
48 A
33 A
38 A
64 A
40 A
46 A
78 A
LP Compressor Capacity @ 175 psi 30 CFM (850 L/min.) 44 CFM (1250 L/min.) 60 CFM (1700 L/min.) 80 CFM (2300 L/min.)
Membrane Input
Operating Pressure
Supply Air Volume
Optimum
Temperature
90-175 psi (6-12 bar)
8-30 SCFM
(212-850 L/min.)
110 +/- 5° F
(43 +/-3° C)
90-175 psi (6-12 bar)
10-36 SCFM
(280-1250 L/min.)
110 +/- 5° F
(43 +/-3° C)
90-175 psi (6-12 bar)
13-60 SCFM
(354-1700 L/min.)
110 +/- 5° F
(43 +/-3° C)
90-175 psi (6-12 bar)
25-80 SCFM
(708-2300 L/min.)
110 +/- 5° F
(43 +/-3° C)
Rated to Supply
F.A.D. for 40% O2 10 CFM (280 L/min.) 15 CFM (420 L/min.) 20 CFM (560 L/min.) 25 CFM (713 L/min.)
F.A.D. for 36% O2 12.5 CFM (350 L/min.) 19 CFM (530 L/min.) 25 CFM (707 L/min.) 31 CFM (877 L/min.)
F.A.D. for 32% O2 17 CFM (480 L/min.) 26 CFM (730 L/min.) 34 CFM (970 L/min.) 43 CFM (1216 L/min.)
LP 560 Shown
Pictured with Optional Nitrox Manager
LP 280 Shown
*Model weight vary depending on Electric Motor Type **Part Number Does Not Include Voltage and Hertz , Customer must specify when ordering.
Nitrox Systems 11
LP 280/420/560/713 Marine Nitrox Generator
*Model Weight vary depending on Electric Motor Type **Part Number Does Not Include Voltage and Hertz , Customer must specify when ordering.
LP 280 ME Shown
LP 560 ME Shown
Nitrox Generator Model LP 280 ME LP 420 ME LP 560 ME LP 713 ME
Part Number 7060ME** 7061ME** 7062ME** 7063ME**
Physical
Specications*
Height
Width
Depth
Weight
Horsepower
41.5 in (105.4 cm)
27 in (68.6 cm)
35 in (88.9 cm)
565 lbs (256 kg)
10 hp (7.5 kW)
49.5 in (125.7 cm)
27 in (68.6 cm)
48 in (121.9 cm)
685 lbs (311 kg)
15 hp (11.2 kW)
49.5 in (125.7 cm)
27 in (68.6 cm)
48 in (121.9 cm)
685 lbs (311 kg)
20 hp (15 kW)
54 in (137.1 cm)
30 in (76.2 cm)
50 in (127 cm)
760 lbs (345 kg)
25 hp (18.6 kW)
Full
Load
Amps
440 V - E3 - 50 or 60 Hz
380 V - E3 - 50 or 60 Hz
230 V - E3 - 50 or 60 Hz
16 A
19 A
30 A
21 A
24 A
48 A
33 A
38 A
64 A
40 A
46 A
78 A
LP Compressor Capacity @ 175 psi 30 CFM (850 L/min.) 44 CFM (1250 L/min.) 60 CFM (1700 L/min.) 80 CFM (2300 L/min.)
Membrane Input
Opterating Pressure
Supply Air Volume
Optimum
Temperature
90-175 psi (6-12 bar)
8-30 SCFM
(212-850 L/min.)
110 +/- 5° F
(43 +/-3° C)
90-175 psi (6-12 bar)
10-36 SCFM
(280-1250 L/min.)
110 +/- 5° F
(43 +/-3° C)
90-175 psi (6-12 bar)
13-60 SCFM
(354-1700 L/min.)
110 +/- 5° F
(43 +/-3° C)
90-175 psi (6-12 bar)
25-80 SCFM
(708-2300 L/min.)
110 +/- 5° F
(43 +/-3° C)
Rated to Supply
F.A.D. for 40% O2 10 CFM (280 L/min.) 15 CFM (420 L/min.) 20 CFM (560 L/min.) 25 CFM (713 L/min.)
F.A.D. for 36% O2 12.5 CFM (350 L/min.) 19 CFM (530 L/min.) 25 CFM (707 L/min.) 31 CFM (877 L/min.)
F.A.D. for 32% O2 17 CFM (480 L/min.) 26 CFM (730 L/min.) 34 CFM (970 L/min.) 43 CFM (1216 L/min.)
12 Nitrox Systems
Voyager
Nitrox Voyager
Physical Specications
Height
Width
Depth
Weight
52 in (133 cm)
38 in (97 cm)
49 in (125 cm)
840 lbs (382 kg)
Full Load Amps
230V - E1 - 50 or 60 Hz**
230V - E3 - 50 or 60 Hz
400V - E3 - 50 or 60 Hz
53 A
49 A
28 A
LP Compressor Capacity @ 175 psi
Horsepower - Electric
23 CFM (665 L/min.)
7.5 hp (5.5 kW)
Volume Tank Capacity 15 gal (57 L)
Membrane Input
Operating Pressure
Supply Air Volume
Optimum Temperature
90-170 psi (6-12 bar)
13-25 SCFM (354-708 L/min.)
110 +/- 5° F(43oC +/- 3°)
HP Nitrox Compressor
Output
Charging Rate
Fill Time
Horsepower - Electric
8.4 CFM, F.A.D. (240 L/min.)
9.5 SCFM*
8.5 minutes*
7.5 hp (5.5 kW)
* Single 80 Cu. Ft. cylinder from 500 - 3000 psi ** Only available with 2 x 5 hp Motors.
Nitrox Systems 13
Commercial Duty Nitrox Generating
Voyager II, III, IV
Nitrox Generator Model Voyager II Voyager III Voyager IV
Physical
Specications
Height
Width
Depth
Weight
62 in (158 cm)
57 in (145 cm)
32 in (81 cm)
1150 lbs (522 kg)
67 in (170 cm)
62 in (158 cm)
35 in (89 cm)
1400 lbs (635 kg)
67 in (170 cm)
62 in (158 cm)
35 in (89 cm)
1450 lbs (658 kg)
Full Load Amps
460V - E3 - 50 or 60 Hz
400V - E3 - 50 or 60 Hz
230V - E3 - 50 or 60 Hz
230V - E1 - 50 or 60 Hz
30 A
35 A
60 A
79 A
38.5 A
44.5 A
77 A
86 A
51 A
59 A
102 A
N/A
LP Compressor Capacity @ 175 psi
Pump
30 CFM (850 L/min.)
RVK 10
44 CFM (1250 L/min.)
RVK 15
59 CFM (1670 L/min.)
RVK 20
Horsepower LP Compressor
HP Compressor
10 hp (7.5 kW)
7.5 hp (5.5 kW)
15 hp (11 kW)
10 hp (7.5 kW)
20 hp (15 kW)
15 hp (11 kW)
HP Compressor F.A.D. for 21% - 40% O2
9.3 CFM
(263 L/min.)
11 CFM
(311 L/min.)
17 CFM
(481 L/min.)
14 Nitrox Systems
Nuvair LP Nitrox Surface Supply
LP > LP 12 R30 > R15 RVK > R15
RVK > Q325
Nitrox Systems 15
Nuvair LP>LP gas, diesel or electric powered Nitrox systems are built for direct surface supply of air or Nitrox at up to 40%
O2 to the diver. This page shows our 12-16 CFM models. Larger models are available on request. The frames are built with
marine grade 6061 aluminum and have a stainless steel compressor/engine plate. This system is supplied in a turn key
package ready to supply the diver and has two oxygen analyzers for complete easy and accurate operation.
Model LP > LP 12 R30 > R15 RVK > R15 RVK > Q325
Physical
Specications
Height
Width
Depth
Weight
57 in (145 cm)
53 in (135 cm)
23 in (58 cm)
624 lbs (284 kg)
70 in (178 cm)
82 in (208 cm)
38 in (97 cm)
1150 lbs (523 kg)
62 in (157 cm)
76 in (193 cm)
35 in (89 cm)
1400 lbs (636 kg)
62 in (157 cm)
76 in (193 cm)
35 in (89 cm)
1470 lbs (668 kg)
Supply Air LP
Compressor
Make
Maximum Pressure
CFM (LPM) Output
Champion R15
175 PSI (12 bar)
23.5 (665 L/min.)
Champion R30
175 PSI (12 bar)
49 (1387 L/min.)
Rotair RVK
175 PSI (12 bar)
42 (1200 L/min.)
Rotair RVK
175 PSI (12 bar)
42 (1200 L/min.)
Air Volume Tank Size 30 Gallons 30 Gallons 30 Gallons 30 Gallons
Air Filtration Type Norgren Series 74 Hankison Series 20 Hankison Series 20 Hankison Series 20
Membrane System Nuvair 10 Nuvair 16 Nuvair 16 Nuvair 16
Heater Type 110 Volt Electric 110 Volt Electric Air/Oil Heat Exchanger
Inverter Size 700 Watt 700 Watt N/A N/A
Nitrox
(Divers Supply)
LP Compressor
Make
Maximum Pressure
CFM (LPM)
ABAC
150 PSI (10 bar)
12 (340 L/min.)
Champion R15
175 PSI (12 bar)
15 (425 L/min.)
Champion R15
175 PSI (12 bar)
16 (453 L/min.)
Quincy 325
250 PSI (17 bar)
16 (453 L/min.)
Nitrox Volume Tank Size N/A 30 Gallon 30 Gallon 30 Gallon
Nitrox Filtration Type N/A Hankison Series 20 Hankison Series 20 Hankison Series 20
Gas Engine
Specications
Make
Power
Honda
20 hp (15 kW)
Honda
24 hp (17.9 kW)
N/A
N/A
N/A
N/A
Diesel Engine
Specications
Make
Power
Kohler
19 hp (15.2 kW)
Kohler
28.5 hp (21.3 kW)
Kohler
28.5 hp (21.3 kW)
Kohler
28.5 hp (21.3 kW)
Fuel Tank Size 6.5 Gallons 15 Gallons 15 Gallons 15 Gallons
Electric
Specications
Make
Power
WEG TEFC
15 hp (11.2 kW)
WEG TEFC
20 hp (15 kW)
WEG TEFC
25 hp (18.7 kW)
WEG TEFC
25 hp (18.7 kW)
Nuvair LP Nitrox Surface Supply
16 Nitrox Systems
Quincy 390 > Nuvair 26 D
Quincy 390 > Nuvair 26 D Model
Physical Specications
Height
Width
Depth
Weight
60 in (152.4 cm)
86 in (218.4 cm)
54 in (137.2 cm)
2900 lbs (1315 kg)
Compressors
LP Capacity @ 175 psi 69 CFM (1954 L/min.)
HP Capacity @ 3600 psi 26.4 SCFM (748 L/min.)
Volume Tank Capacity 60 gal (303 L)
* No LP Volume Tank is required
Q390 with 20 hp High Pressure Pictured
Nitrox Systems 17
Quincy 390 > Nuvair 26 E
Quincy 390 > Nuvair 26 E Model
Physical Specications
Height
Width
Depth
Weight
57 in (144.8 cm)
80 in (203.2 cm)
48 in (121.9 cm)
2600 lbs (1179 kg)
Full Load Amps
440V - E3 - 50 or 60 Hz
380V - E3 - 50 or 60 Hz
230V - E3 - 50 or 60 Hz
54 A
76 A
108 A
Compressors LP Capacity @ 175 psi 69 CFM (1954 L/min.)
HP Capacity @ 3600 psi 26.4 SCFM (748 L/min.)
Volume Tank Capacity 60 gal (303 L)
* No LP Volume Tank is required
Q370 with 15 hp High Pressure Pictured
18 Nitrox Systems
Nuvair Commercial LP Nitrox 10 - 25 hp
LP 500D Pictured
Nitrox Systems 19
Model LP 280G LP 280D LP 420G LP 420D LP 500D
Part Number 7056.2 7056.4 7056.3 7056.5
Physical
Specications
Height
Width
Depth
Weight
60 in (152 cm)
40 in (102 cm)
28 in (70.5 cm)
450 lbs (204 kg)
45 in (114 cm)
40 in (102 cm)
26 in (66 cm)
572 lbs (260 kg)
64 in (163 cm)
46 in (117 cm)
32 in (81 cm)
620 lbs (280 kg)
44 in (112 cm)
48 in (122 cm)
34 in (86 cm)
671 lbs (305 kg)
46 in (117 cm)
54 in (137 cm)
36 in (91 cm)
796 lbs (361 kg)
Supply Air LP
Compressor
Make
Max Pressure
CFM (LPM)
Output
Rotair RVG
175 PSI (12 bar)
23 (651 L/min.)
Rotair RVG
175 PSI (12 bar)
32 (900 L/min.)
Rotair RVK
175 PSI (12 bar)
39 (1100 L/min.)
Rotair RVK
175 PSI (12 bar)
36 (1020 L/min.)
Rotair RVK
175 PSI (12 bar)
60 (1700 L/min.)
Air Filtration Type Hankison Series 20 Hankison Series 20 Hankison Series 24 Hankison Series 24 Hankison Series 24
Membrane System Nuvair 10 Nuvair 10 Nuvair 16 Nuvair 16 Nuvair 20
Heater Type Air/Oil Heat Exchanger
Engine
Specications
Make & Type
Model
Power
Honda Gas
GX390U1QNR2
11 hp (8.2 kW )
@ 3600 rpm
Kubota Diesel
Z602
13 hp (10.4 kW)
Honda Gas
GX670UTXF2
20.5 hp (15.3 kW)
@ 3600 rpm
Kohler Diesel
25LD425-2
19 hp (14 kW)
@ 3600 rpm
Kohler Diesel
9LD626-2
28.5 hp (21 kW)
@ 3000 rpm
Fuel Tank Size 2.5 Gallons 4 Gallons 10 Gallons 10 Gallons 10 Gallons
Nitrox Supply
F.A.D. for 40 %
F.A.D. for 36 %
F.A.D. for 32 %
9 CFM (255 L/min.)
12 CFM (340 L/min.)
15.5 CFM (440 L/min.)
10 CFM (283 L/min.)
12.5 CFM (350 L/min.)
17 CFM (480 L/min.)
15 CFM (420 L/min.)
19 CFM (530 L/min.)
26 CFM (730 L/min.)
15 CFM (420 L/min.)
19 CFM (530 L/min.)
26 CFM (730 L/min.)
18 CFM (509 L/min.)
22 CFM (623 L/min.)
30 CFM (849 L/min.)
Gas or diesel powered Nitrox systems for use to supply another low pressure or high pressure compressor with Nitrox at up
to 40% O2. The advantage of this package is it can normally be used with a compressor that you already own. The frames
are built with 6061 Marine Grade Aluminum and the compressor plate is made with 316 stainless steel. All systems come
with large air and oil coolers for better ltration and longer lter life.
Nuvair Commercial LP Nitrox 10 - 25 hp
20 Nitrox Systems
Nuvair Nitrox Commercial HP in Electric, Gas or Diesel 10 - 20 hp
MCH36D Pictured
Nitrox Systems 21
Nuvair Nitrox Commercial HP MCH30G MCH30D MCH36D
Physical
Specications
Height
Width
Depth
Weight
44 in. (111.8 cm)
64 in. (162.8 cm)
32 in. (81.3 cm)
710 lbs (322 kg)
44 in. (111.8 cm)
64 in. (162.8 cm)
32 in. (81.3 cm)
760 lbs (345 kg)
44 in. (111.8 cm)
64 in. (162.8 cm)
32 in. (81.3 cm)
900 lbs (408 kg)
Engine
Specications
Make and Type Honda Gas Kohler Diesel Kohler Diesel
Model GX670UTXF2 25LD425-2 9LD626-2
Power 20.5 hp (15.3 kW) @ 3600 rpm 19 hp (14 kW)@ 3600 rpm 28.5 hp (21 kW) @ 3000r pm
Fuel Tank Size 6.5 Gallons 6.5 Gallons 10 Gallons
LP Air Filtration Type Hankison Series 24 Hankison Series 24 Hankison Series 24
Membrane System
Membrane Size Nuvair 16 Nuvair 16 Nuvair 20
Required LP Supply Air 21 - 50 CFM
@ 90 - 175 PSI
21 - 50 CFM
@ 90 - 175 PSI
26 - 63 CFM
@ 90 - 175 PSI
Optimum Temperature 110°F +/- 5° (43°C +/- 3°) 110°F +/- 5° (43°C +/- 3°) 110°F +/- 5° (43°C +/- 3°)
HP Nitrox
Compressors
Output 17.5 CFM (500 L/min.) FAD 17.5 CFM (500 L/min.) FAD 22 CFM (622 L/min.) FAD
Charging Rate 21 SCFM 21 SCFM 26.4 SCFM
Fill Time
(500 - 3000 PSI) 3.8 minutes 3.8 minutes 3.08 minutes
Horsepower - Electric 15 hp (11.2 kW) 15 hp (11.2 kW) 20 hp (15 kW)
Nuvair Nitrox Commercial HP in Electric, Gas or Diesel 10 - 20 hp
22 Low Pressure Compressors
Low Pressure Compressors
Champion - Quincy - Rotair - Gas - Electric - Diesel
Nuvair offers a wide range of LP Compressors in standard and custom congurations. Check
out our LP catalog or website for more information on our complete line of LP Compressors.
High Pressure Compressors 23
Coltri/Nuvair Portable
Stainless Steel Option Pictured
Model MCH6 / 3 E MCH6 / 3.5 E MCH6 / 3.5 G
Filling Time* Approx. 23 Minutes Approx. 19 Minutes Approx. 19 Minutes
Cubic Feet/Minute 2.8 FAD 3.4 SCFM* 3.5 FAD 4.2 SCFM* 3.5 FAD 4.2 SCFM*
Liters/Minute 80 FAD 100 FAD 100 FAD
Motor Options Single Phase Electric Three Phase Electric Honda Gas
(Part# 8013)
115 V - E1 - 50 or 60 Hz 28 Amp (Part# 8015)** N/A
230 V - E1 - 50 or 60 Hz 14 Amp (Part# 8014.1)** N/A N/A
230 V - E3 - 50 or 60 Hz N/A 11 Amp (Part# 8016.4)** N/A
Driven by 3 hp (2.2 kW) 4 hp (3 kW) 5.5 hp (4 kw)
Max Operating Pressure 4500 PSI (310 Bar) 4500 PSI (310 Bar) 4500 PSI (310 Bar)
RPM 2240 2800 2800
Number of Stages 4 4 4
Number of Fill Hoses 1 1 1
Condensate Drain Manual Manual Manual
Sound Level @ 3 Meters 82 dB 83 dB 87 dB
Dimensions:
(H x W x D)
15.5 in x 26.5 in x 15 in
(39 x 67 x 38 cm)
15 in x 26 in x 15 in
(38 x 65 x 38 cm)
15 in x 31 in x 14 in
(38 x 79 x 36 cm)
Weight 90 lbs (41 kg) 88 lbs (40 kg) 84 lbs (38 kg)
Lubrication Splash Lubrication, capacity 11 oz.
Air Quality DIN 3188 - CGA Grade E - NFPA 1500 - EN12021
The compact dimensions and light weight of this compressor make it very easy to transport and
operate. These compressors are ideal for lling cylinders at home, on boats or on dive trips.
Fill hose and air ltration system included.
* Single 80 Cu.. Ft. cylinder from 500 to 3000 PSI ** Part number reects 60Hz Model. Inquire about 50 Hz Model
24 High Pressure Compressors
Coltri/Nuvair Compact Portable
The sturdy enclosure and easily accessible lifting handles on this series of compressors makes it ideal
for portable applications. It is available in a full range of electric and gas power for lling cylinders at
home, at the dive shop or on boats. Fill hose and air ltration system included.
Model MCH6 / 3 E MCH6 / 3.5 E MCH6 / 3.5 G
Filling Time* Approx. 23 Minutes Approx. 19 Minutes Approx. 19 Minutes
Cubic Feet/Minute 2.8 FAD 3.4 SCFM* 3.5 FAD 4.2 SCFM* 3.5 FAD 4.2 SCFM*
Liters/Minute 80 FAD 100 FAD 100 FAD
Motor Options Single Phase Electric Three Phase Electric Honda Gas
(Part# 8013-C)
115 V - E1 - 50 or 60 Hz 28 Amp (Part# 8015-C)** N/A
230 V - E1 - 50 or 60 Hz 14 Amp (Part# 8014.1-C)** N/A N/A
230 V - E3 - 50 or 60 Hz N/A 11 Amp (Part# 8016.2-C)** N/A
Driven by 3 hp (2.2 kW) 4 hp (3 kW) 5.5 hp (4 kw)
Max Operating Pressure 4500 PSI (310 Bar) 4500 PSI (310 Bar) 4500 PSI (310 Bar)
RPM 2240 2800 2800
Number of Stages 4 4 4
Number of Fill Hoses 1 1 1
Condensate Drain Manual Manual Manual
Sound Level @ 3 Meters 82 dB 83 dB 87 dB
Dimensions:
(H x W x D)
19 in x 29 in x 14.5 in
(48 x 74 x 37 cm)
19 in x 29 in x 14.5 in
(48 x 74 x 37 cm)
19 in x 29 in x 14.5 in
(48 x 74 x 37 cm)
Weight 110 lbs (50 kg) 108 lbs (49 kg) 108 lbs (49 kg)
Lubrication Splash Lubrication, capacity 11 oz.
Air Quality DIN 3188 - CGA Grade E - NFPA 1500 - EN12021
* Single 80 Cu.. Ft. cylinder from 500 to 3000 PSI ** Part number reects 60Hz Model. Inquire about 50 Hz Model
High Pressure Compressors 25
Coltri/Nuvair Standard Electric
The Nuvair Standard Electric uses a pumping unit that is made from top quality materials; connecting
rods from aluminum alloy, stainless steel intercoolers and aftercoolers that are more than four meters
in length, and cylinders of special cast iron. The electric motor uses an aluminum housing to keep
weight to a minimum, making the station very compact.
Model MCH13 / 5MCH13 / 7MCH16 / 9
Filling Time* Approx. 11 Minutes Approx. 9 Minutes Approx. 7.4 Minutes
Cubic Feet/Minute 4.7 FAD 6.6 SCFM* 7.6 FAD 8.9 SCFM* 9.4 FAD 10.8 SCFM*
Liters/Minute 135 FAD 215 FAD 265 FAD
Motor Options Single or Three Phase Single or Three Phase Single or Three Phase
230 V - E1 - 50 or 60 Hz 19 Amp 25 Amp (Part# 8020.1)** 34 Amp (Part# 8022.1)**
230 V - E3 - 50 or 60 Hz 11 Amp 14 Amp (Part# 8019.2)** 20 Amp (Part# 8022.2)**
440 V - E3 - 50 or 60 Hz N/A 7 Amp (Part# 8019.3)** 10 Amp (Part# 8022.3)**
Driven by 4 hp (3 kW) 5.5 hp (4 kW) 7.5 hp (5.5 kw)
Max Operating Pressure 5000 PSI (345 Bar) 5000 PSI (345 Bar) 5000 PSI (345 Bar)
RPM 890 1350 1550
Number of Stages 3 3 3
Number of Fill Hoses 2 2 2
Condensate Drain Manual Manual Manual
Sound Level @ 3 Meters 75 dB 81 dB 82 dB
Dimensions:
(H x W x D)
25 in x 34 in x 18 in
(64 x 86 x 45 cm)
25 in x 34 in x 18 in
(64 x 86 x 45 cm)
25 in x 34 in x 18 in
(64 x 86 x 45 cm)
Weight 218 lbs (99 kg) 218 lbs (99 kg) 218 lbs (99 kg)
Lubrication Splash Lubrication, capacity 1.6 qts.
Air Quality DIN 3188 - CGA Grade E - NFPA 1500 - EN12021
* Single 80 Cu.. Ft. cylinder from 500 to 3000 PSI ** Part number reects 60Hz Model. Inquire about 50 Hz Model
26 High Pressure Compressors
Model MCH13 / 7 MCH16 / 9
Filling Time* Approx. 9 Minutes Approx. 7.4 Minutes
Cubic Feet/Minute 7.6 FAD 8.9 SCFM* 9.4 FAD 10.8 SCFM*
Liters/Minute 215 FAD 265 FAD
Motor Options Single or Three Phase Single or Three Phase
230 V - E1 - 50 or 60 Hz 25 Amp 5.5 hp (4 kW) (Part# 8040.1)** 34 Amp 7.5 hp (5.5 kw) (Part# 8037.1)**
230 V - E3 - 50 or 60 Hz 14 Amp 5.5 hp (4 kW) (Part# 8040.2)** 20 Amp 7.5 hp (5.5 kw) (Part# 8037.2)**
440 V - E3 - 50 or 60 Hz 7 Amp 5.5 hp (4 kW) (Part# 8040.3)** 10 Amp 7.5 hp (5.5 kw) (Part# 8037.3)**
Honda Gas 6.5 hp (4.1 kW) (Part# 8039) 9 hp (6.6 kW) (Part# 8038)
Yanmar Diesel N/A 10 hp (7.5kW) (Part# 8038-DY)
Kohler Diesel N/A 10 hp (7.5kW) (Part# 8038-DL)
Max Operating Pressure 5000 PSI (345 Bar) 5000 PSI (345 Bar)
RPM 1350 1550
Number of Stages 3 3
Number of Fill Hoses 2 2
Condensate Drain Manual Manual
Sound Level @ 3 Meters 81 dB 80-96 dB
Dimensions: (H x W x D) 24 in x 45 in x 22 in (61 x 114 x 56 cm)
Weight 320-421 lbs (145-191 kg)
Lubrication Splash Lubrication, capacity 1.6 qts.
Air Quality DIN 3188 - CGA Grade E - NFPA 1500 - EN12021
Coltri/Nuvair Mini Tech
The Mini Tech is our go to Compressor set up for a wide variety of applications in both breathing air
and industrial air use. Compact design and fold away handles make for easy lifting and portability
of the compressor. On board Grade E air purication
insures breathing air quality standards. A wide variety of
customized options to meet individual needs are noted on
the options list below. If portability and dependability are
top on your list, this is the compressor for you.
* Single 80 Cu.. Ft. cylinder from 500 to 3000 PSI ** Part number reects 60Hz Model. Inquire about 50 Hz Model
pictured with multiple options
optional stainless
High Pressure Compressors 27
Coltri/Nuvair 250
The Tech 250 has the features of the Mini Tech plus a panel for gauges, ll whips or anything else that
you would like mounted on it. There is also extra room for upgraded ltration.
Model MCH16 / 250
Filling Time* Approx. 7.4 Minutes
Cubic Feet/Minute 9.4 FAD 10.8 SCFM*
Liters/Minute 265 FAD
Motor Options Single or Three Phase
230 V - E1 - 50 or 60 Hz 34 Amp 7.5 hp (5.5 kw) (Part# 8030.1)
230 V - E3 - 50 or 60 Hz 20 Amp 7.5 hp (5.5 kw) (Part# 8031.2)
440 V - E3 - 50 or 60 Hz 10 Amp 7.5 hp (5.5 kw) (Part# 8031.3)
Honda Gas (Electric Start) 9 hp (6.6 kW) (Part# 8027-EL)
Yanmar Diesel (Electric Start) 10 hp (7.5kW) (Part# 8028-DY-EL)
Kohler Diesel (Electric Start) 10 hp (7.5kW) (Part# 8029-DL-EL)
Max Operating Pressure 5000 PSI (345 Bar)
RPM 1550
Number of Stages 3
Number of Fill Hoses 2
Condensate Drain Manual
Sound Level @ 3 Meters 80-96 dB
Dimensions: (H x W x D) 31 in x 44 in x 23 in (79 x 112 x 58 cm)
Weight 320-421 lbs (145-191 kg)
Lubrication Splash Lubrication, capacity 1.6 qts.
Air Quality DIN 3188 - CGA Grade E - NFPA 1500 - EN12021
* Single 80 Cu.. Ft. cylinder from 500 to 3000 PSI ** Part number reects 60Hz Model. Inquire about 50 Hz Model
28 High Pressure Compressors
Coltri/Nuvair Compact & EVO (Models 7 and 9)
*Single 80 Cu. Ft. cylinder from 500 to 3000 PSI ** Part number reects 60Hz Model. Inquire about 50 Hz Model
The Compact Series includes a semi-sound proofed lling station. The compressor switches off
automatically when the pressure level set by the operator is reached. Condensate is discharged
automatically. External access simplies oil level monitoring and changes. The Compact is also
offered as an EVO model with Interstage Pressure Gauges, High Temp, and Low Oil Shutdown
included.
Model MCH13 / 7 MCH16 / 9
Filling Time* Approx. 9 Minutes Approx. 7.4 Minutes
Cubic Feet/Minute 7.6 FAD 8.9 SCFM* 9.4 FAD 10.8 SCFM*
Liters/Minute 215 FAD 265 FAD
Motor Options Single or Three Phase Single or Three Phase
230 V - E1 - 50 or 60 Hz 25 Amp 34 Amp (Part# 8033.1)**
230 V - E3 - 50 or 60 Hz 14 Amp 20 Amp (Part# 8032.2)**
440 V - E3 - 50 or 60 Hz 7 Amp 10 Amp (Part# 8032.3)**
Motor Power 5.5 hp (4 kW) 7.5 hp (5.5 kw)
Max Operating Pressure 5000 PSI (345 Bar) 5000 PSI (345 Bar)
RPM 1350 1550
Number of Stages 3 3
Number of Fill Hoses 2 2
Condensate Drain Automatic Automatic
Fill Pressure Stop Automatic Automatic
Sound Level @ 3 Meters 79 dB 81 dB
Dimensions***:
(H x W x D)
33 in x 35 in x 24 in
(84 x 89 x 60 cm)
33 in x 35 in x 24 in
(84 x 89 x 60 cm)
Weight 310-400 lbs (141-181 kg) 332-430 lbs (151-195 kg)
Lubrication Splash Lubrication, capacity 1.6 qts.
Air Quality DIN 3188 - CGA Grade E - NFPA 1500 - EN12021
***Single phase enclosure 33 in x 42 in x 28 in (84 x 105 x 70 cm)
EVO Cabinet with options
High Pressure Compressors 29
Coltri/Nuvair Compact (Models 14 and 18)
The lling station utilizes two completely independent compressors for reliability and versatility.
Operation is fully automatic and up to four cylinders can be lled simultaneously as well as storage
banks. The container is lined with a sound reduction material which limits noise. The Compact can be
used with our LP280 to produce Nitrox you can pump 18 CFM at 32% using both compressors, or up
to 40% at 9 CFM using one compressor.
Model MCH26 / 14 MCH32 / 18
Filling Time* Approx. 4.5 Minutes Approx. 3.7 Minutes
Cubic Feet/Minute 14.8 FAD 17.8 SCFM* 18.4 FAD 21.6 SCFM*
Liters/Minute 420 FAD 520 FAD
Motor Options Single or Three Phase Three Phase
230 V - E1 - 50 or 60 Hz 2 x 25 Amp N/A
230 V - E3 - 50 or 60 Hz 2 x 14 Amp 2 x 20 Amp (Part# 8036.2)**
440 V - E3 - 50 or 60 Hz 2 x 7 Amp 2 x 10 Amp (Part# 8036.3)**
Motor Power 2 x 5.5 hp (4 kW) 2 x 7.5 hp (5.5 kw)
Max Operating Pressure 5000 PSI (345 Bar) 5000 PSI (345 Bar)
RPM 1350 1550
Number of Stages 3 3
Number of Fill Hoses 4 4
Condensate Drain Automatic Automatic
Fill Pressure Stop Automatic Automatic
Sound Level @ 3 Meters 72 dB 75 dB
Dimensions:
(H x W x D)
53 in x 35 in x 34 in
(133 x 89 x 85 cm)
53 in x 35 in x 34 in
(133 x 89 x 85 cm)
Weight 629 lbs (286 kg) 673 lbs (306 kg)
Lubrication Splash Lubrication, capacity 2 x 1.6 qts.
Air Quality DIN 3188 - CGA Grade E - NFPA 1500 - EN12021
* Single 80 Cu.. Ft. cylinder from 500 to 3000 PSI ** Part number reects 60Hz Model. Inquire about 50 Hz Model
30 High Pressure Compressors
Coltri/Nuvair Mini Silent
The Mini Silent Series uses a very compact, sound proofed container. Completely automatic operation
ensures that the compressor switches off when the maximum pressure set on the dial a pressure
switch is reached. The condensate periodically drains through automatic pneumatic valves into a
collection tank. Due to it’s small footprint this compressor is great for use in boats and shops.
Model MCH13 / 7 MCH16 / 9
Filling Time* Approx. 9 Minutes Approx. 7.4 Minutes
Cubic Feet/Minute 7.6 FAD 8.9 SCFM* 9.4 FAD 10.8 SCFM*
Liters/Minute 215 FAD 265 FAD
Motor Options Single or Three Phase Three Phase
230 V - E1 - 50 or 60 Hz 25 Amp N/A
230 V - E3 - 50 or 60 Hz 14 Amp 20 Amp (Part# 8034.2)**
440 V - E3 - 50 or 60 Hz 7 Amp 10 Amp (Part# 8034.3)**
Motor Power 5.5 hp (4 kW) 7.5 hp (5.5 kw)
Max Operating Pressure 5000 PSI (345 Bar) 5000 PSI (345 Bar)
RPM 1350 1550
Number of Stages 3 3
Number of Fill Hoses 2 2
Condensate Drain Automatic Automatic
Fill Pressure Stop Automatic Automatic
Sound Level @ 3 Meters 72 dB 75 dB
Dimensions: (H x W x D) 42 in x 28 in x 25 in (105 x 70 x 62 cm) 42 in x 28 in x 25 in (105 x 70 x 62 cm)
Weight 390 lbs (177 kg) 410 lbs (187 kg)
Lubrication Splash Lubrication, capacity 1.6 qts.
Air Quality DIN 3188 - CGA Grade E - NFPA 1500 - EN12021
*Single 80 Cu. Ft. cylinder from 500 to 3000 PSI ** Part number reects 60Hz Model. Inquire about 50 Hz Model
High Pressure Compressors 31
Coltri/Nuvair Super Silent EVO
The Super Silent EVO has been sound-proofed so well that only a sound level under 70 dB can be
heard from just a few feet away. It is a fully automatic station with a complete range of instrumentation
for ease of operation. The pump is a three-stage unit with cylinders made of special heavy duty cast
iron. The compressed air is cooled with a stainless steel aftercooler that ensures the air entering the
lter system is only 25o F hotter than the intake air. There are safety relief valves for each stage of
compression. It has two condensate separators and one lter chamber with a replaceable cartridge.
This ensures the air compressed into the cylinders is clean and free of contaminates.
Model MCH13 / 7 MCH 16 / 9
Filling Time* Approx. 9 Minutes Approx. 7.4 Minutes
Cubic Feet/Minute 7.6 FAD 8.9 SCFM*9.4 FAD 10.8 SCFM*
Liters/Minute 215 FAD 265 FAD
Motor Options Single or Three Phase Three Phase
230 V - E1 - 50 or 60 Hz 25 Amp N/A
230 V - E3 - 50 or 60 Hz 14 Amp 20 Amp (Part# 8035.2)**
440 V - E3 - 50 or 60 Hz 7 Amp 10 Amp (Part# 8035.3)**
Motor Power 5.5 hp (4 kW) 7.5 hp (5.5 kw)
Max Operating Pressure 5000 PSI (345 Bar) 5000 PSI (345 Bar)
RPM 1350 1550
Number of Stages 3 3
Number of Fill Hoses 2 2
Condensate Drain Automatic Automatic
Fill Pressure Stop Automatic Automatic
Sound Level @ 3 Meters 66 dB 69 dB
Dimensions: (H x W x D) 54 in x 36 in x 35 in (137 x 90 x 87 cm) 54 in x 36 in x 35 in (137 x 90 x 87 cm)
Weight 466 lbs (177 kg) 488 lbs (187 kg)
Lubrication Splash Lubrication, capacity 1.6 qts.
Air Quality DIN 3188 - CGA Grade E - NFPA 1500 - EN12021
*Single 80 Cu. Ft. cylinder from 500 to 3000 PSI ** Part number reects 60Hz Model. Inquire about 50 Hz Model
32 High Pressure Compressors
Coltri/Nuvair 26 Open
The 26 Open package is designed for high use in hot humid conditions and is rated for continuous duty
use up to 6000psi. It has the MCH36 four stage compressor block with a 26.4SCFM charging rate.
Purchase, maintenance and operation costs are signicantly lower than similar sized compressors in
the market place.
Model MCH30 / 21 MCH 36 / 26
Filling Time* Approx. 4 Minutes Approx. 3.3 Minutes
Cubic Feet/Minute 17.5 FAD 21 SCFM* 22 FAD 26.4 SCFM*
Liters/Minute 500 FAD 623 FAD
Motor Three Phase Three Phase
230 V - E3 - 60 Hz 31 Amp 15 hp (11 kw) (Part # 8042.2) 35.5 Amp 20 hp (15 kw) (Part # 8044.2)
400 V - E3 - 50 Hz 18 Amp 15 hp (11 kw) (Part # 8042.6) 20 Amp 20 hp (15 kw) (Part # 8044.6)
460 V - E3 - 60 Hz 16 Amp 15 hp (11 kw) (Part #8042.3) 22 Amp 20 hp (15 kw) (Part # 8044.3)
Max Operating Pressure 6000 PSI (414 Bar) 6000 PSI (414 Bar)
RPM 1100 1300
Number of Stages 4 4
Number of Fill Hoses 4 4
Condensate Drain Automatic Automatic
Fill Pressure Stop Automatic Automatic
Sound Level @ 3 Meters 75 dB 77 dB
Dimensions: (H x W x D) 60 in x 40 in x 30 in (153 x 102 x 76 cm)
Weight 800 lbs (363 kg)
Lubrication Pressure Lubrication, capacity 4.5 qts.
Air Quality DIN 3188 - CGA Grade E - NFPA 1500 - EN12021
*Single 80 Cu. Ft. cylinder from 500 to 3000 PSI
High Pressure Compressors 33
Coltri/Nuvair 26 Enclosed Silenced
High volume facilities where sound may be an issue should look at our Enclosed Silent 26.4 SCFM*
charging rate compressor, rated for continuous duty at up to 6000psi. Unsurpassed in quality, reliability
and price. The Enclosed Silenced package is designed for high use in work areas where noise can not
be tolerated.
Model MCH30 / 21 MCH36 / 26
Filling Time* Approx. 4 Minutes Approx. 3.3 Minutes
Cubic Feet/Minute 17.5 FAD 21 SCFM* 22 FAD 26.4 SCFM*
Liters/Minute 500 FAD 623 FAD
Motor Three Phase Three Phase
230 V - E3 - 60 Hz 31 Amp 15 hp (11 kw) (Part # 8043.2) 35.5 Amp 20 hp (15 kw) (Part # 8045.2)
400 V - E3 - 50 Hz 18 Amp 15 hp (11 kw) (Part # 8043.6) 20 Amp 20 hp (15 kw) (Part # 8045.6)
460 V - E3 - 60 Hz 16 Amp 15 hp (11 kw) (Part # 8043.3) 22 Amp 20 hp (15 kw) (Part # 8045.3)
Max Operating Pressure 6000 PSI (414 Bar) 6000 PSI (414 Bar)
RPM 1100 1300
Number of Stages 4 4
Number of Fill Hoses 4 4
Condensate Drain Automatic Automatic
Fill Pressure Stop Automatic Automatic
Sound Level @ 3 Meters 68 dB 70 dB
Dimensions: (H x W x D) 65.5 in x 37 in x 52 in (169 x 94 x 132 cm)
Weight 925 lbs (420 kg)
Lubrication Pressure Lubrication, capacity 4.5 qts.
Air Quality DIN 3188 - CGA Grade E - NFPA 1500 - EN12021
*Single 80 Cu. Ft. cylinder from 500 to 3000 PSI
34 Fill Containment Station
Nuvair Fill Containment Station
Model Cylinders Pneumatic/
Manual
Dual/Single
Pressure
NCC-2 2Manual Single
NSS-2P 2Pneumatic Single or Dual
NSS-3P 3Pneumatic Single or Dual
NSS-4P 3Pneumatic Single or Dual
Model Weight Dimensions (H x W x D)
NCC-2 488 lbs (221 kg) 41 in x 26 in x 29 in (104x66x74 cm)
NSS-2 555 lbs (252 kg) 59 in x 26 in x 29 in (150x66x74 cm)
NSS-3 754 lbs (342 kg) 59 in x 41 in x 24 in (150x104x61 cm)
NSS-4 978 lbs (444 kg) 59 in x 49 in x 27 in (150x125x69 cm)
Options will change weight of cabinets
Scuba whip
DIN whip
SCBA whip
Gas Analyzers 35
O2 Quickstick
A Simple Solution for Every Nitrox Diver
The O2
Quickstick is the rst Diver Friendly oxygen analyzer available anywhere! Easy to use
effective and amazingly affordable! The O2 Quickstickis designed for the Nitrox diver who wants
the security and convenience of having his own O2 analyzer and doesn’t want to pay a small fortune to
own one. Operating the O2 Quickstick is as simple as pointing at the tank valve and releasing Nitrox,
with only one hand needed! Features an On/Off switch and the replaceable thermally compensated
sensor maintains accuracy levels that exceed dive industry standards. The unit is totally O-ring sealed
for excellent water resistance and is one of the lowest priced consumer analyzers on the market.
Specications O2 Quickstick* (Part#9455)
Range 0.1-100.0% Oxygen (0-1 ATA PPO2)
Display Accuracy +/- 0.1%
Sensor Type Electrochemical
Expected Sensor Life, Room Air 36 Months
Power 9V Alkaline Battery
Response Time Less Than 6 Seconds to 90% of Final Value
Operating Temperature 32-104oF (0-40oC)
Storage Temperature 32-122oF (0-50oC)
Pressure Sensitive to Partial Pressure
Humidity 0-99% RH (Non-Condensing)
Warranty 36 Months Pro-Rated
*All specications are at ambient / sea level, 77oF (25oC)
36 Gas Analyzers
The Standard for Monitoring Nitrox
Pro O2
Oxygen Analyzer Series
Three Styles of Oxygen Analyzers to Accommodate Most Applications:
Specications Pro O2*
Range 0.1-100.0% Oxygen (0-1 ATA PPO2)
Display Accuracy +/- 0.1%
Sensor Type Electrochemical
Expected Sensor Life, Room Air 36 Months
Power 9V Alkaline Battery
Response Time Less Than 6 Seconds to 90% of Final Value
Operating Temperature 32-104oF (0-40oC)
Storage Temperature 32-122oF (0-50oC)
Pressure Sensitive to Partial Pressure
Humidity 0-99% RH (Non-Condensing)
Warranty 36 Months Pro-Rated
*All specications are at ambient / sea level, 77oF (25oC)
Gas Analyzers 37
Nuvair Pro He
Specications Pro He* (Part#HE)
Range 0.1-100.0% Helium in Oxygen and/or Nitrogen
Display Accuracy +/- 1% at Constant Temperature and Pressure
Sensor Type Solid State Thermal Conductivity (Helium)
Battery Power 4 C-Cell Alkaline Batteries ANSI-14A, IEC-LR14
Response Time 90% in Less than 5 Seconds
Operating Temperature 32-104oF (0-40oC)
Storage Temperature 32-122oF (0-50oC)
Display 3 1/2 in LCD
Battery Life Approximately 150 Hours Continuous Use
*All specications are at ambient / sea level, 77oF (25oC)
38 Gas Analyzers
NuvairPro Trimix
Helium/Oxygen Analyzer
Featured as a Portable Unit
Also Available as a Wall Mount
Specications Pro Trimix* (Part#HE-O2)
Range 0.1-100.0% Helium in Oxygen and/or Nitrogen
0-100% Oxygen in Nitrogen and/or Helium
Display Accuracy Helium / Oxygen +/- 2% of FS at Constant Temperature;
+/- 5% Over Operating Temperature Range
Sensor Type Solid State Thermal Conductivity (Helium)
Power 4 C-Cell Alkaline Batteries ANSI-14A, IEC-LR14
Response Time 90% of Final Value in Less than 7 Seconds
Operating Temperature 32-104oF (0-40oC)
Storage Temperature 32-122oF (0-50oC)
Display 3 1/2 in LCD
Battery Life Approximately 150 Hours Continuous Use
*All specications are at ambient / sea level, 77oF (25oC)
Gas Analyzers 39
Nuvair Pro CO
The Carbon Monoxide Analyzer For the Safe Diver
Specications Pro CO* (Part #9625)
Range 0-100 ppm CO
Display Accuracy +/- 1%
Sensor Type Electrochemical
Expected Cell Life, Room Air 18 Months
Power 9Volt battery
Response Time less than 50 Seconds
Operating Temperature 41-10 4 oF (5-40oC)
Storage Temperature 41-10 4 oF (5 to 40oC)
Operating Humidity 15 to 90% r.h.
Warranty 12 Months
*All specications are at ambient / sea level, 77oF (25oC) **Calibration must be done with calibration CO test gas
40 Gas Analyzers
Nuvair Pro CO2
Carbon Dioxide Analyzer
Specications Pro CO2 * (Part#9616)
Maximum Gas Flow Rate 600 cc/min. or 1/2 liter/min.
Accuracy (assumes accurate recent calibration) Better than 50 ppm + or - resolution
Repeatability (assumes stable atm press and temp) Better than + 1 ppm
Warm up time at 72o F ( 22o C) 1 minute to +/- 0.2% 10 Minutes Max Accuracy
Full Scale Resolution (FSR) 0 to 2500 is 50 ppm
Temperature Performance + or - 10% of reading up to 50% FSD
+ or - 15% of reading up to 50% to100% FSD
Storage Temperature Range -4o F to 122o F (-20o to 50o C)
Humidity Range 0 to 95% RH, Non-Condensing
Power Requirements 9 Volt battery
Dimensions (H x W x D) 4 1/8 in x 2 1/2 in x 1 7/8 in (10.5 x 6.35 x 4.8 cm)
Weight 7 ounces (200 g)
Warranty 1 Year Limited
*Specications subject to change without notice.
The Pro CO2 is the latest of the Nuvair Pro analyzer line. It comes in a small compact black box just
like the Pro O2 or the Pro CO and is just as easy to use. The high performance sensor provides a
temperature compensated and linear CO2 measurement over the sensing range. The sensor contains
a long life tungsten lament infrared light source, an optical cavity into which gas diffuses, a dual
temperature compensated pyro-electric infrared detector, an integral semiconductor temperature
sensor and electronics to process the signals from the pyro-electric detector.
Compressor Oil 41
Nuvair 455
(Part # quart - 9408, gallon - 9406)
Premium Synthetic Food Grade Breathing Air Compressor Oil
Application
Nuvair455 is an ISO 100 USDA H1 premium quality oil
designed for use in high pressure and low pressure breathing
air systems for the diving industry. The unique additive system,
never before used in this application, is best possible for
preventing wear and carbon residue buildup.
Nuvair455 is suitable for use in reciprocating compressors
operating on up to 40% oxygen enriched air. However, as the
oxygen content increases, the oil life will decrease.
Typical
Properties
ASTM Test
Method
Nuvair
455
SAE Grade 30
ISO Viscosity Grade D2422 100
Viscosity,
cSt @ 40oC
cSt @ 104oF
D445 100 cSt
D445 14.0
Viscosity Index D2270 144
Pour Point
oC
oF
D97
D97
-35
-31
Flash Point
oC
oF
D92
D92
240
464
Specic Gravity D1298 0.85
USDA Authorization H1 or H2 H-1
Demulsibility D1401 Excellent
HP and LP Reciprocating Compressors
Nuvair 546
(Part #: quart - 9411, gallon - 9409)
Food Grade Rotary Screw Compressor Oil
Application
Nuvair™ 546 is designed for 2,000 hours of use
in rotary screw compressors where a food grade
lubricant is needed. USDA H-1 rated Nuvair™ 546
meets all requirements under FDA Regulation 21
CFR 172.878 and 178.3570.
Typical
Properties
ASTM Test
Method
Nuvair
546
SAE Grade 20
ISO Viscosity Grade D-2422 46
Viscosity,
cSt @ 104oF
cSt @ 40oC
D-445 46 cSt
Viscosity Index D-2270 145
Pour Point
oC
oF
D-97
D-97
-54
-65
Flash Point
oC
oF
D-92
D-92
260
500
Evaporation D-972 1.0%
Foaming Sequence
I, II, III
D-892 Nil
Copper Corrosion D-130 1A
Specic Gravity D-1298 0.84
USDA Authorization H1 or H2 H-1
Demulsibility D-1401 Excellent
42 Compressor Oil
Nuvair 751
(Part #: quart - 9405, gallon - 9403)
Premium Synthetic Diester Based HP
Reciprocating Breathing Air Compressor Oil
Application
Nuvair751 is a Diester/Organic compound blend,
which is compatible with most currently used
compressor components including seals, paints
and plastics. However, some materials are not
recommended for use with diester oils. Please contact
Nuvair for further information. Certain conditions
require accelerated oil changes, as there are many
factors, including heat and oxidation that cause oil
degradation. Call for our recommendation.
Typical
Properties
ASTM Test
Method
Nuvair
751
SAE Grade 40
ISO Viscosity Grade D-2422 150
Viscosity,
cSt @ 104oF
cSt @ 40oC
D-445 164cSt
Viscosity Index D-2270 80
Pour Point
oC
oF
D-97
D-97
-34
-30
Flash Point
oC
oF
D-92
D-92
271
520
Carbon Residue D-189 <0.02%
Evaporation D-972 0.90%
Foaming Sequence
I, II, III
D-892 Nil
Copper Corrosion D-130 1A
Specic Gravity D-1298 0.94
USDA Authorization H1 or H2 H-2
Demulsibility D-1401 Excellent
Application
Nuvair™ 800 is a high viscosity synthetic
oil based on the latest technology.
Using a highly stable triester base
uid, the product is designed for use in
reciprocating compressors under adverse
conditions of high temperature and high
pressure.
Typical Properties ASTM Test
Method
Nuvair
800
ISO Viscosity Grade D2422 150
Viscosity
cSt. @ 100° C
cSt. @ 40° C
cSt. @ 210° F
cSt. @ 100° F
D445
D445
D445
D445
14.1
145.9
13.6
175 .1
Pour Point oC
oF
D97
D97
-29
-20
Flash Point oC
oF
D92
D92
287
550
Auto Ignition Temp oC
oF
D1255
D1255
390
735
Water Solubility 0.01 g/l @20° C D1255 Insoluble
Specic Gravity D1298 0.970
Lbs/Gallon 8.08
Evaporation D972 <1.0%
Nuvair 800
(Part #: quart - 9414, gallon - 9412)
Nuvair
Nuvair
2949 West 5th Street,
Oxnard CA USA
Phone 1-805-815-4044
Fax 1-805-815-4196
Email : info@nuvair.com
Web : www.nuvair.com