69 1120 Programmable Thermostat By Duracraft TD2200 Honeywell TD2400 En
User Manual: TD2200
Open the PDF directly: View PDF
.
Page Count: 36
| Download | |
| Open PDF In Browser | View PDF |
Programmable Thermostat by Duracraft OWNER’S GUIDE Weekday/Weekend (5-day/ 2-day) Programmable Heat and/or Cool Low Voltage (20 to 30 Vac) Thermostat and Mounting Plate Model TD2400 1 69-1120 Welcome to the world of comfort and energy savings with your new Duracraft Programmable Thermostat. Your new thermostat will automatically control the temperature in your home, keeping you comfortable while saving energy when programmed according to the instructions in this manual. RECYCLING THERMOSTAT If this thermostat is replacing a thermostat that contains mercury in a sealed tube, do not place your old thermostat in the trash. Contact your local waste management authority for instructions regarding recycling and the proper disposal of your old thermostat. Direct any questions concerning the application of this thermostat to Duracraft Consumer Services at 1-800-554-4558, Monday-Friday 7:00 a.m.-5:30 p.m., Eastern time. If you have questions, call Duracraft at 1-800-554-4558. MERCURY SWITCH Fig. 1. Typical location of a mercury switch in a thermostat. M3701 2 69-1120 Table Of Contents Step 1. Prepare For Installation ..................................................................................................... 4 Step 2. Remove Old Thermostat .................................................................................................... 6 Step 3. Install The Batteries ........................................................................................................... 7 Step 4. Program The Thermostat ................................................................................................ 10 Step 5. Adjust Fan Operation Switch, as Required .................................................................... 18 Step 6. Adjust System On-Time, °F/°C, as Required .................................................................. 18 Step 7. Mount Thermostat Mounting Plate ................................................................................. 20 Step 8. Wire Thermostat Terminals ............................................................................................. 21 Step 9. Mount The Thermostat ..................................................................................................... 25 Step 10. Check Thermostat Operation After Programming and Installing .............................. 26 Step 11. Set The Fan and System Switches ............................................................................... 28 Troubleshooting Guide ................................................................................................................. 30 Limited One-Year Warranty ............................................................................... Inside Back Cover 3 69-1120 Step 1. Prepare for Installation ❑ Check Table 1 to make sure this thermostat is compatible with your system. If not, return to retailer. For more information, call Duracraft Consumer Services, toll-free 1-800-554-4558. Table 1. Compatibility Chart. System Type Gas—Standing Pilot Gas—Electronic Ignition Gas-Fired Boilers Gas—Millivolt Oil-Fired Boilers Oil-Fired Furnace Electric Furnace Electric Air Conditioning Baseboard Electric (120/240 Line Volt) Heat Pumps/Multistage Equipment Compatible With TD2400 Yes Yes Yesa,b No Yesa,b Yes Yes Yes No No Not compatible with any 120/240 volt circuit. aCompatible with 2-wire Honeywell zone valves. Isolating relay required for 3-wire thermostats for zone valves. Not compatible with 2-wire White-Rodgers no. 1361 valves. bCompatible with hot water baseboard systems. Will not work efficiently on steam or gravity systems. 4 69-1120 ❑ Acquire tools and items as needed (below). Also purchase two AA alkaline batteries; we recommend Energizer® batteries. CROSS-RECESSED SCREWDRIVER HAND OR POWER DRILL WITH 3/16 INCH DRILL BIT, IF NEEDED TO DRILL HOLES IN WALL WIRE CUTTER/STRIPPER OR SHARP KNIFE, IF NEEDED TO STRIP WIRES MASKING TAPE, IF NEEDED TO LABEL WIRES AS DISCONNECTED FROM OLD THERMOSTAT LEVEL, IF NEEDED TO LEVEL THERMOSTAT FOR APPEARANCE 5 M878B 69-1120 Step 2. Remove Old Thermostat masking tape to label it with the old terminal designation. If there are only two wires, they do not need to be labeled. If there is an extra wire that is not connected to your old thermostat, you will also not be connecting it to your new thermostat. Keep the wires from falling back into the wall by wrapping them around a pencil as shown. ❑ Test to make certain that your heating and cooling systems are working properly. If either does not work, contact your local heating/air conditioning dealer. To avoid compressor damage, do not operate the cooling system when outdoor temperature is below 50°F (10°C). WIRES THROUGH ❑ TURN OFF POWER to system at the WALL OPENING furnace, or at the fuse/circuit breaker panel. ❑ Carefully unpack your new thermostat and mounting plate; save package of screws, instructions and receipt. M5136 ❑ Remove cover from old thermostat. If it does not snap off when pulled firmly from Replacing a Clock Thermostat that has the bottom, check for a screw used to lock on the cover. C or C1 Clock Terminals? ❑ Loosen screws holding thermostat to If you are replacing a Honeywell Chronotherm® subbase, wallplate or wall, and lift away. Thermostat, you may find one or two wires that ❑ Disconnect wires from old thermostat or go to the C or C1 clock terminals on the subbase. As you disconnect each wire, use 6 69-1120 Chronotherm® Thermostat wiring wallplate. Do not allow them to touch, or you may damage your transformer. Disconnect the wires and wrap them separately, using electrical tape. Do not wrap them together. Place the wires where they will not interfere with the operation of the new thermostat. Record the colors and terminal designation labels of the remaining wires. Three thermostat wires? If you have three wires for heating only and can operate the fan using the fan ON switch, this thermostat will work with your system. However, some hot water (zoned) heating systems have three thermostat wires. The thermostat will not work without installing an isolating relay on these systems. For details, call Duracraft Consumer Services at 1-800554-4558. Six or more wires? If there are six or more wires (excluding clock wires attached to terminals), you most likely have a variation of a heat pump or multistage system. The thermostat is not compatible with such systems so return the product to the place of purchase. If you would like information about which programmable thermostats will work with your system, call Duracraft Consumer Services at 1-800-554-4558. Step 3. Install the Batteries IMPORTANT Batteries must be installed for programming and operation of the thermostat and heating/cooling system. 7 69-1120 ❑ Purchase two AA alkaline batteries; nonalkaline batteries will not last as long, and may leak, causing damage to the thermostat or the wall surface. We recommend Energizer® batteries. ❑ Open the top cover of thermostat to access control panel and battery compartment. ❑ Make sure the thermostat is set in the OFF position. ❑ Use a coin to remove battery cover. ❑ Install the fresh batteries as shown, making sure positive and negative terminals are oriented correctly. ❑ Replace battery cover. BATTERY DOOR COVER REMOVING BATTERY DOOR M12492 As the batteries are running low, a bAt Lo indicator will flash for 1 to 2 months before batteries run out completely. Replace the batteries as soon as possible after the indicator starts flashing. If you do not replace the batteries sometime during the flashing bAt Lo, the indicator will eventually stop flashing. bAtLo will stay on without flashing, indicating the thermostat and heating/cooling system have stopped working when the batteries are almost completely dead. 8 69-1120 After the batteries are completely dead, the bAt-Lo indicator will disappear, leaving a completely blank display. the display is blank, the batteries are dead or incorrectly installed and you will have to reprogram. See pages 14 to 17 to reprogram. Press down on left ends of batteries to remove. If you insert the new batteries within 20 to 30 seconds of removing the old ones, you will not have to reprogram the thermostat. However, if IMPORTANT Although the thermostat has a low battery indicator, replace the batteries once a year to prevent the thermostat and heating/cooling system from shutting down due to lack of battery power. INSTALL TWO AA ALKALINE BATTERIES AS SHOWN As a precaution, when leaving home for longer than a month, change batteries before you leave to prevent system from shutting down due to lack of battery power. M1713 9 69-1120 • WAKE is the time period you want the house at a comfortable temperature when you get up and while you get ready for work or school. (This will be a higher temperature during heating season, or a lower temperature during cooling season.) • LEAVE is the time period you can set for an energy-saving temperature while you are away at work or school. (This will be a lower temperature during heating season, or a higher temperature during cooling season.) • RETURN is the time period you want the house at a comfortable temperature for activities before bedtime. (Again, higher heat or lower cool.) Step 4. Program the Thermostat After the batteries are installed, the thermostat can be easily programmed in your hand before it is installed on the wall. If you would prefer to program the thermostat after it is installed on the wall, skip to page 20, and return later to this programming section. The personal programming chart on pages 12 and 13 may be helpful for planning your program schedule of time and temperature settings for various times of the day. Four time periods are available during weekdays — WAKE, LEAVE, RETURN, and SLEEP; these periods can be seen individually on the display as you press the Weekday key. 10 69-1120 it. For example, a house that is occupied during weekdays would only require programs for WAKE and SLEEP. • SLEEP is the time period you can set for an energy-saving temperature while you are sleeping. (Again, lower heat or higher cool. For more comfortable sleeping, some people choose not to raise the cool temperature during the night.) If no program is entered for the weekends, the thermostat will operate on the weekday SLEEP program all weekend. Before programming, remove the clear plastic overlay covering the display. You will set one schedule for weekdays and another for weekends, because your requirements will probably be different for each. Also, during weekends, only the WAKE and SLEEP time periods are available. When pressing the keys, use the ball of your finger or a soft pencil eraser. Using sharp fingernails or pencil points can damage the keypad. Fill in the times and temperatures you desire for weekdays and weekends. If you decide not to program the thermostat, it will automatically control heating at 68°F (20°C), and cooling at 78°F (26°C), 24 hours a day. Also, you do not need to enter a time and temperature program for all periods if your schedule does not require If you make an error at any time during programming, just press the Run Program key, and continue again at the step where you left off. 11 69-1120 Personal Programming Chart Weekdays Heating Program Start Time Heating Temperaturea WAKE LEAVE RETURN SLEEP Weekendsb WAKE SLEEP aThe temperatures cannot be set any higher than 88°F (31°C) or any lower than 45°F (7°C). bIf you decide not to enter weekend programs, the SLEEP from the weekday program will copy to the weekend schedule. 12 69-1120 Weekdays Cooling Program Start Time Cooling Temperaturea WAKE LEAVE RETURN SLEEP Weekendsb WAKE SLEEP aThe temperatures cannot be set any higher than 88°F (31°C) or any lower than 45°F (7°C). bIf you decide not to enter weekend programs, the SLEEP from the weekday program will copy to the weekend schedule. NOTE: If you decide not to program the thermostat, it will automatically control heating at 68°F (20°C), and cooling at 78°F (26°C), 24 hours a day. 13 69-1120 This guide can be used for programming your new thermostat. NOTE: Batteries are required for operation and programming. When inserting batteries, set system switch to OFF. Remove battery door (on thermostat left side) using a coin at the bottom. Follow instructions on pages 8 and 9. Also note that the label inside the battery cover contains an abbreviated set of programming procedures for the thermostat. Set Current Time/Day Time Clock/Day To set time, press and release once, press until current time shows. To set day, Time Clock/Day press and release again, press Run Program until current day shows; then press Heating Program . Weekday With System switch at Heat, press and release SET appear on display. once. WAKE, MON FRI (Monday-Friday), and 14 69-1120 TEMP Time Use to program WAKE time and to program WAKE temperature for MON FRI (Monday-Friday). Repeat sequence for LEAVE, RETURN, SLEEP. Time Weekend Press until SAT SUN (Saturday-Sunday), WAKE and SET appear on display. Use to TEMP program WAKE time and to program WAKE temperature for SAT SUN (Saturday-Sunday). Run Program Repeat sequence for SLEEP. Press and release to start the program. Cooling Program With System switch at Cool, follow the same instructions as for the Heating Program. Run Program After programming, adjust the fan and system switches as desired. Press and release the program. 15 to start 69-1120 A quick guide for operating or making changes follows. NOTE: System switch must be set to Heat or Cool to perform the following: TEMP Temporarily Change temperature for current period only—Press ; temporary indicator will Run Program show on display and cancel itself at the next scheduled change; to cancel sooner, press . TEMP Hold Temp Hold a temperature indefinitely (such as if on vacation)—Press and ; HOLD will appear Run Program on display; to cancel, press . Present Set Check Current Temperature Setting—Press pressing this will cancel your change.) . (If using TEMPORARY CHANGE or HOLD, 16 69-1120 Weekday Check Programs—Press Weekend , repeatedly to see each time and temperature; Run Program then press . Weekday Cancel Program—Press , Clear Weekend until program to cancel shows; then press . Usage Check Usage — Press for length of time heat or air conditioning has been running today since Clear midnight; press again for yesterday’s usage, press again for cumulative; press to clear Run Program cumulative reading if desired; then press . Permanently Change a Program—Repeat steps under Heating Program or Cooling Program (page 14 and 15) as applicable. Run Program Return to normal program or start program —Press 17 . 69-1120 Step 5. Adjust Fan Operation Switch, As Required ❑ The thermostat fan operation switch, labeled FUEL SWITCH (see illustration on page 19) is factory-set in the F position. This is the correct setting for most systems. If your system is an electric heat system, set the switch to E. The E setting will allow the fan to turn on immediately with the heating or cooling in a system where the G terminal is connected. Step 6. Adjust System On-Time, °F/°C, As Required ❑ The thermostat on-time is factory-set for a warm air, gas or oil heating system. If you are installing it on another type of system, adjust the on-time accordingly by setting screws A and B on the back of the thermostat. use the heating system table shown in the illustration (page 19) as a guide. The system on-time should be optimized according to the type of system to minimize room temperature swings. Setting the screw “out one turn” means turning the screw approximately 360° counterclockwise, or about one complete turn. In the unlikely event that you want a longer furnace on-time, readjust screws A and/or B as follows: 18 69-1120 ❑ The thermostat is set to read the temperature in degrees Fahrenheit. If readings are desired in degrees Celsius, adjust screw C out one turn, as shown in illustration. First, turn in both screws completely, then adjust for system type: • Warm Air Furnace—Set at the Hot Water setting (A—out one turn, B—leave in). • Electric Furnace—Leave at the Warm Air Furnace setting (A—leave in, B—leave in). THERMOSTAT BACK A C B D DISPLAY °F C–IN DISPLAY °C C–OUT 1 TURN NOTE: This thermostat does not have a setting for steam/gravity air. Cycles would not be long enough for accurate temperature control. ADJUST SCREWS THROUGH HOLES TO SELECT OPERATION DESIRED FUEL SWITCH HEATING SYSTEM POSITION F WARM AIR A–IN B–IN FURNACE F HOT WATER A–OUT B–IN BOILER 1 TURN E ELECTRIC A–IN B–OUT FURNACE 1 TURN W Y G FOR HIGH EFFICIENCY FURNACE (90%+ AFUE) ADJUST: SCREW A–OUT ONE TURN SCREW B–IN FUEL SWITCH – F POSITION FUEL SWITCH IMPORTANT When using a high efficiency furnace such as a 90% or greater AFUE (Average Fuel Utilization Efficiency) unit, adjust screw A out one turn and leave screw B in. F E R Rc M8796 19 69-1120 Step 7. Mount Thermostat Mounting Plate ❑ Reposition mounting plate over holes, pulling wires through wiring opening. Loosely insert two mounting screws into holes. ❑ Level for appearance only; thermostat will function properly even when not level. Tighten mounting screws. ❑ Position mounting plate on wall. Use level to make sure mounting plate is level. Use a pencil to mark the two mounting holes. ❑ Remove mounting plate from wall, and drill 3/16-inch holes in wall (if drywall) as marked. For firmer material such as plaster or wood, drill WALL ANCHORS (2) WIRES THROUGH 7/32-inch WALL OPENING holes. Gently WALL tap anchors (provided) into drilled holes MOUNTING PLATE until flush with the wall. MOUNTING SCREWS (2) LEVEL M1714A M1718 20 69-1120 ❑ In 5-wire installations only, be sure to remove the factory-installed jumper connecting terminals R and Rc. Step 8. Wire Thermostat Terminals NOTE: All wiring must comply with local codes and ordinances. If unsure about household wiring procedures, call your local heating/air conditioning contractor. METHOD TO INCREASE WIRE LENGTH Refer to masking tape labels you placed on wires when you removed your old thermostat. WIRE NUT SIZE FOR TWO 18-GAUGE WIRES WIRE FROM WALL ❑ Match the letter of your old thermostat wire with the terminal of the corresponding letter on the back of your new thermostat. Refer to illustrations on pages 23 and 24. Hold the thermostat as shown to minimize need for wire extenders. If wires are still too short, use wire connectors (purchased locally) to extend wires. See figure for guidelines on using wire extenders. 6 IN. (152 MM) OF 18-GAUGE THERMOSTAT WIRE. MATCH INSULATION COLORS OR MARK WIRE ENDS. M1715A 21 69-1120 ❑ Loosen the terminal screws and slip each wire beneath its matching terminal. See illustration (lower right) for wire insertion technique. securely tighten terminals. ❑ Plug the hole in the wall with insulation to help prevent drafts from adversely affecting thermostat operation. M3002A Y G 22 W END OF WIRE VISIBLE HERE JUMPER (FACTORYINSTALLED) REMOVE IF 5-WIRE SYSTEM Rc INSERT STRAIGHT UNDER SCREW HEAD R 5/16 in. (8 mm) STRIP M1712A 69-1120 4-WIRE HEAT/COOL (JUMPER INTACT) 2-WIRE HEAT-ONLY (JUMPER INTACT) A C B D W Y A C B D JUMPER G W Y G JUMPER Rc R HEATING RELAY OR VALVE COIL L1 (HOT) R HEATING RELAY OR VALVE COIL COOLING CONTACTOR COIL 1 L2 1 Rc POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. FAN RELAY L1 (HOT) L2 M1709B 1 23 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M1710B 69-1120 3-WIRE COOL-ONLY (JUMPER INTACT) 5-WIRE HEAT/COOL (JUMPER REMOVED) A C B D W Y A C B D W G Y G JUMPER R HEATING RELAY OR VALVE COIL R Rc COOLING CONTACTOR COIL FAN RELAY COOLING CONTACTOR COIL 1 FAN RELAY 1 L1 (HOT) L1 (HOT) L2 L2 1 Rc L1 (HOT) L2 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M848A POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. M1711B 24 69-1120 Step 9. Mount The Thermostat NOTE: To remove thermostat from wall, first pull out at bottom of thermostat, then remove top. A. ENGAGE TABS AT TOP OF THERMOSTAT AND SUBBASE. B. PRESS LOWER EDGE OF CASE TO LATCH. C. SWING OPEN COVER TO CHECK OPERATION. AM TU LEAVE Clock/Day Time TEMP Run Progra m Weekday Hold Temp Weekend Fan Auto Clear Usage On Cool Present Set System Off Heat M12494 25 69-1120 Step 10. Check Thermostat Operation After Programming and Installing Heating Do not check heating system operation by jumpering thermostat terminals, such as the gas valve, zone valve, oil burner control at the primary control. This will damage the thermostat; Instead, jumper R and W wires at the thermostat. Cool Off Auto Heat Move the System switch to Heat and the Fan switch to Auto. On TEMP Press TEMP key until the setting is about 10°F (6°C) above room temperature. Heating should start and the fan should run after a short delay (immediately if fan operation switch is set in E position). Press TEMP key until setting is about 10°F (6°C) below room temperature. The heating equipment should shut off. 26 69-1120 Cooling To avoid possible compressor damage, do not operate the cooling system when outside temperature is below 50°F (10°C). See compressor manufacturer instructions for further information. Cool Off Auto Heat Move the System switch to Cool and the Fan switch to Auto. On Press TEMP key until setting is about 10°F (6°C) below room temperature. The cooling equipment and fan should start. TEMP NOTE: When cooling setting is changed, thermostat may delay up to five minutes before turning on the air conditioner. This delay protects the compressor. Press TEMP key until the setting is about 10°F (6°C) above room temperature. The cooling equipment and fan should stop. Cool Off Auto Heat On 27 Move the System switch to Off, with the Fan switch still at Auto. The system and fan should be off. 69-1120 Step 11. Set The Fan and System Switches First set the Fan switch. Fan Auto: Normal setting for most homes. A single-speed fan will turn on automatically with the air conditioner or furnace. A twospeed fan will usually run on high with the air conditioner and on low with the furnace. Auto On Auto On Exception: If Fan Operation Switch on back of thermostat is set to E position (see page 16), fan will operate with furnace only. Fan On: The fan runs continuously. Use for improved air circulation during special occasions or for more efficient electronic air cleaning. (In a heat-only system, fan will run continuously only if fan relay is connected to the thermostat.) 28 69-1120 Then set the System switch. Cool: The thermostat controls your air conditioning system. Off: Both the heating and air conditioning systems are off. Heat: The thermostat controls your heating system. 29 Cool Off Heat Cool Off Heat Cool Off Heat 69-1120 Troubleshooting Guide IF… Display will not come on. Temperature display will not go lower than 45°F (7°C) or higher than 88°F (31°C) during programming. Temperature change occurs at the wrong times. THEN… q Set the System switch to Off. Remove batteries. Insert backward for at least 5 seconds to reset thermostat. Replace batteries correctly. Display should come on. q Make sure batteries are fresh and installed correctly. q Gently clean battery contacts using a soft pencil eraser. Do not use anything abrasive on the clips. q You have reached the temperature setting limit. The setting range is 45°F to 88°F (7°C to 31°C). q Check the program times for the period in question. Be sure that AM and PM indications are correct. Make sure the current day and time are correct. Reprogram if necessary. 30 69-1120 Heating will not come on. q Check that switch on thermostat is set to Heat. q Check the system fuse or circuit breaker and replace or reset if necessary. q Check for correct wiring and good connections. q Jumper wires R and W. If heat does not come on, contact your heating dealer. q If display is blank or says bAt Lo, install fresh batteries. q If temperature setting is higher than current Cooling will not come on. q q q q q temperature, and the display says Heat, contact Duracraft Consumer Services at 1-800-554-4558. Check that switch on thermostat is set to Cool. Check the system fuse or circuit breaker and replace or reset if necessary. Check for correct wiring and good connections. Jumper wires Rc and Y. If cooling does not come on, contact your cooling dealer. If display is blank or says bAt Lo, install fresh batteries. 31 69-1120 Cooling will not come on. (continued) q The thermostat has a built-in time delay on q q q The house is too warm or too cool. q q cooling. Allow 5 to 10 minutes after changing the setting before the air conditioner starts. Make sure outdoor disconnect is energized (on). If temperature setting is lower than current temperature, and the display says Cool, move system switch from Cool to Off for 10 minutes. After 10 minutes, return switch to Cool position. If air conditioner comes on, compressor may have reached its high limit temperature protection and shut down. If air conditioner does not come on after the 10 minutes and the display says Cool, contact Duracraft Consumer Services at 1-800554-4558. If 2- or 4-wire installation, verify R-Rc jumper is installed. Press Present Set key to check the current temperature setting. If desired, change the temperature setting. See page 16. 32 69-1120 SYSTEM ON indicator is lit, but no heat is coming from the registers. q Allow time for the furnace to heat up and the fan to come on before checking for heat at the register. (Check to make sure system on-time is set correctly according to page 18 and 19.) q Readjust system on-time according to instructions on pages 18 and 19. The furnace cycles too frequently or the system cycle length is too short or too long. The thermostat's current setting does q Check that the wiring hole in the wall behind the not match the display temperature to wallplate has been plugged with insulation to within ±1°. prevent drafts that might adversely affect thermostat operation. q Be aware that it is normal for the current setting and display temperature to differ on occasion. q During recovery from setback or setup, setting and display temperatures may differ for up to 30 minutes after recovery period. 33 69-1120 Incorrect room temperature showing on thermostat display. q Make sure the hole behind the thermostat is plugged with insulation to help prevent drafts from adversely affecting the thermostat operation. q The thermostat is factory-calibrated and cannot be adjusted. Toll-free Customer Assistance For all questions concerning this thermostat, please read and follow the instructions. If additional assistance is needed, call Duracraft Consumer Services toll-free at 1-800-554-4558, Monday Friday, 7:00 a.m. - 5:30 p.m. Eastern time. Before you call, please have the following information available—thermostat model number and date code, kind of heating/cooling system (i.e., hot water, warm air, oil, gas, etc.), number of wires connected to the thermostat. NOTICE This equipment is a Class B digital apparatus, which complies with Canadian Radio Interference Regulations, CRC c.1374. 34 69-1120 Limited One-Year Warranty Duracraft Corporation warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Duracraft shall repair or replace it (at Duracraft’s option) within a reasonable period of time. If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or (ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction, and mail it, postage prepaid, to the following address: Duracraft Corporation Consumer Services 250 Turnpike Road South borough, MA 01772 This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Duracraft that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Duracraft’s sole responsibility shall be to repair or replace the product within the terms stated above. DURACRAFT SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY DURACRAFT MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Duracraft Corporation, Consumer Services, 250 Turnpike Road, Southborough, MA 01772 or call 1-800-544-4558. Monday-Friday, 7:00 a.m. to 5:30 p.m., Eastern time. 35 69-1120 TYPICAL ENERGY SAVINGS FOR REPRESENTATIVE CITIES IN THE U.S. AND CANADA Savings for Once-A-Day 10°F (5°C) decrease Savings for Twice-A-Day 10°F (5°C) decrease* Savings for 5°F (3°) summer increase Approximate percentage of energy cost savings 30% 28% 26% 24% 22% 20% 18% 16% 14% 12% 10% 8% 6% 4% 2% Minneapolis St. Paul Montreal Ottawa Toronto Edmonton Regina Winnipeg Calgary Moncton North Bay Quebec St. John's Halifax Vancouver Buffalo Cleveland Milwaukee Denver Des Moines Omaha Salt Lake City Boston Chicago Detroit Pittsburgh Indianapolis Cincinnati Kansas City St. Louis Columbus Louisville New York Philadelphia Portland Wash., D C Seattle San Francisco Dallas Atlanta Los Angeles *Based on 10°F (5°C) decrease—(5°F [3°C] decrease gives approximately 55 percent of these savings). ® U.S. Registered Trademark 69-1120 7-97 R.T. Printed in U.S.A. on recycled paper containing at least 10% 36 post-consumer paper fibers. San Diego M2416A 69-1120
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Fill forms, Extract, Assemble, Print high-res Create Date : 1997:07:11 09:04:33 Producer : Acrobat Distiller 3.0 for Power Macintosh Subject : Owner's Guide Creator : Adobe PageMaker 6.5 Title : 69-1120 - Programmable Thermostat by Duracraft Author : H&BC Technical Communications Modify Date : 2001:02:26 11:05:42-06:00 Page Count : 36EXIF Metadata provided by EXIF.tools