69 1120 Programmable Thermostat By Duracraft TD2200 Honeywell TD2400 En

User Manual: TD2200

Open the PDF directly: View PDF PDF.
Page Count: 36

Download69-1120 - Programmable Thermostat By Duracraft TD2200 Honeywell-TD2400-en
Open PDF In BrowserView PDF
Programmable Thermostat
by Duracraft
OWNER’S GUIDE
Weekday/Weekend (5-day/ 2-day)
Programmable Heat and/or Cool
Low Voltage (20 to 30 Vac)
Thermostat and Mounting Plate
Model TD2400

1

69-1120

Welcome to the world of comfort and energy
savings with your new Duracraft Programmable Thermostat.
Your new thermostat will automatically control
the temperature in your home, keeping you
comfortable while saving energy when programmed according to the instructions in this
manual.

RECYCLING THERMOSTAT
If this thermostat is replacing a thermostat that contains mercury in a sealed
tube, do not place your old thermostat in
the trash. Contact your local waste
management authority for instructions
regarding recycling and the proper
disposal of your old thermostat.

Direct any questions concerning the application
of this thermostat to Duracraft Consumer
Services at 1-800-554-4558, Monday-Friday
7:00 a.m.-5:30 p.m., Eastern time.

If you have questions, call Duracraft at
1-800-554-4558.
MERCURY
SWITCH

Fig. 1. Typical
location of a
mercury switch in
a thermostat.
M3701

2

69-1120

Table Of Contents
Step 1. Prepare For Installation ..................................................................................................... 4
Step 2. Remove Old Thermostat .................................................................................................... 6
Step 3. Install The Batteries ........................................................................................................... 7
Step 4. Program The Thermostat ................................................................................................ 10
Step 5. Adjust Fan Operation Switch, as Required .................................................................... 18
Step 6. Adjust System On-Time, °F/°C, as Required .................................................................. 18
Step 7. Mount Thermostat Mounting Plate ................................................................................. 20
Step 8. Wire Thermostat Terminals ............................................................................................. 21
Step 9. Mount The Thermostat ..................................................................................................... 25
Step 10. Check Thermostat Operation After Programming and Installing .............................. 26
Step 11. Set The Fan and System Switches ............................................................................... 28
Troubleshooting Guide ................................................................................................................. 30
Limited One-Year Warranty ............................................................................... Inside Back Cover

3

69-1120

Step 1. Prepare for Installation
❑ Check Table 1 to make sure this thermostat is compatible with your system. If not, return to
retailer. For more information, call Duracraft Consumer Services, toll-free 1-800-554-4558.
Table 1. Compatibility Chart.
System Type
Gas—Standing Pilot
Gas—Electronic Ignition
Gas-Fired Boilers
Gas—Millivolt
Oil-Fired Boilers
Oil-Fired Furnace
Electric Furnace
Electric Air Conditioning
Baseboard Electric (120/240 Line Volt)
Heat Pumps/Multistage Equipment

Compatible With TD2400
Yes
Yes
Yesa,b
No
Yesa,b
Yes
Yes
Yes
No
No

Not compatible with any 120/240 volt circuit.
aCompatible with 2-wire Honeywell zone valves. Isolating relay required for 3-wire thermostats for zone valves.
Not compatible with 2-wire White-Rodgers no. 1361 valves.
bCompatible with hot water baseboard systems. Will not work efficiently on steam or gravity systems.
4
69-1120

❑ Acquire tools and items as needed (below). Also purchase two AA alkaline batteries; we
recommend Energizer® batteries.

CROSS-RECESSED
SCREWDRIVER

HAND OR POWER
DRILL WITH 3/16 INCH
DRILL BIT, IF NEEDED TO
DRILL HOLES IN WALL

WIRE CUTTER/STRIPPER OR SHARP
KNIFE, IF NEEDED TO STRIP WIRES

MASKING TAPE, IF
NEEDED TO LABEL WIRES
AS DISCONNECTED FROM
OLD THERMOSTAT

LEVEL, IF NEEDED TO LEVEL
THERMOSTAT FOR APPEARANCE

5

M878B

69-1120

Step 2. Remove Old Thermostat

masking tape to label it with the old terminal
designation. If there are only two wires, they
do not need to be labeled. If there is an
extra wire that is not connected to your old
thermostat, you will also not be connecting it
to your new thermostat. Keep the wires from
falling back into the wall by wrapping them
around a pencil as shown.

❑ Test to make certain that your heating and
cooling systems are working properly. If
either does not work, contact your local
heating/air conditioning dealer. To avoid
compressor damage, do not operate the
cooling system when outdoor temperature is
below 50°F (10°C).
WIRES THROUGH
❑ TURN OFF POWER to system at the
WALL OPENING
furnace, or at the fuse/circuit breaker panel.
❑ Carefully unpack your new thermostat and
mounting plate; save package of screws,
instructions and receipt.
M5136
❑ Remove cover from old thermostat. If it
does not snap off when pulled firmly from
Replacing a Clock Thermostat that has
the bottom, check for a screw used to lock
on the cover.
C or C1 Clock Terminals?
❑ Loosen screws holding thermostat to
If you are replacing a Honeywell Chronotherm®
subbase, wallplate or wall, and lift away.
Thermostat, you may find one or two wires that
❑ Disconnect wires from old thermostat or
go to the C or C1 clock terminals on the
subbase. As you disconnect each wire, use 6
69-1120

Chronotherm® Thermostat wiring wallplate. Do
not allow them to touch, or you may damage
your transformer. Disconnect the wires and
wrap them separately, using electrical tape. Do
not wrap them together. Place the wires where
they will not interfere with the operation of the
new thermostat. Record the colors and
terminal designation labels of the remaining
wires.

Three thermostat wires?
If you have three wires for heating only and
can operate the fan using the fan ON switch,
this thermostat will work with your system.
However, some hot water (zoned) heating
systems have three thermostat wires. The
thermostat will not work without installing an
isolating relay on these systems. For details,
call Duracraft Consumer Services at 1-800554-4558.

Six or more wires?
If there are six or more wires (excluding clock
wires attached to terminals), you most likely
have a variation of a heat pump or multistage
system. The thermostat is not compatible with
such systems so return the product to the
place of purchase. If you would like information
about which programmable thermostats will
work with your system, call Duracraft Consumer Services at 1-800-554-4558.

Step 3. Install the Batteries
IMPORTANT
Batteries must be installed for
programming and operation of the
thermostat and heating/cooling
system.

7

69-1120

❑ Purchase two AA alkaline batteries; nonalkaline batteries will not last as long, and
may leak, causing damage to the thermostat or the wall surface. We recommend
Energizer® batteries.
❑ Open the top cover of thermostat to access
control panel and battery compartment.
❑ Make sure the thermostat is set in the OFF
position.
❑ Use a coin to remove battery cover.
❑ Install the fresh batteries as shown, making
sure positive and negative terminals are
oriented correctly.
❑ Replace battery cover.

BATTERY
DOOR COVER

REMOVING
BATTERY
DOOR
M12492

As the batteries are running low, a bAt Lo
indicator will flash for 1 to 2 months before
batteries run out completely. Replace the
batteries as soon as possible after the indicator
starts flashing. If you do not replace the
batteries sometime during the flashing bAt Lo,

the indicator will eventually stop flashing. bAtLo will stay on without flashing, indicating the
thermostat and heating/cooling system have
stopped working when the batteries are almost
completely dead.
8

69-1120

After the batteries are completely dead, the
bAt-Lo indicator will disappear, leaving a
completely blank display.

the display is blank, the batteries are dead or
incorrectly installed and you will have to
reprogram. See pages 14 to 17 to reprogram.

Press down on left ends of batteries to remove.
If you insert the new batteries within 20 to 30
seconds of removing the old ones, you will not
have to reprogram the thermostat. However, if

IMPORTANT
Although the thermostat has a low
battery indicator, replace the batteries
once a year to prevent the thermostat
and heating/cooling system from
shutting down due to lack of battery
power.

INSTALL TWO AA ALKALINE
BATTERIES AS SHOWN

As a precaution, when leaving home for longer
than a month, change batteries before you
leave to prevent system from shutting down
due to lack of battery power.

M1713

9

69-1120

• WAKE is the time period you want the
house at a comfortable temperature when
you get up and while you get ready for work
or school. (This will be a higher temperature
during heating season, or a lower temperature during cooling season.)
• LEAVE is the time period you can set for an
energy-saving temperature while you are
away at work or school. (This will be a lower
temperature during heating season, or a
higher temperature during cooling season.)
• RETURN is the time period you want the
house at a comfortable temperature for
activities before bedtime. (Again, higher
heat or lower cool.)

Step 4. Program the Thermostat
After the batteries are installed, the thermostat
can be easily programmed in your hand before
it is installed on the wall.
If you would prefer to program the thermostat
after it is installed on the wall, skip to page 20,
and return later to this programming section.
The personal programming chart on pages 12
and 13 may be helpful for planning your
program schedule of time and temperature
settings for various times of the day.
Four time periods are available during weekdays — WAKE, LEAVE, RETURN, and
SLEEP; these periods can be seen individually
on the display as you press the Weekday key.

10

69-1120

it. For example, a house that is occupied
during weekdays would only require programs
for WAKE and SLEEP.

• SLEEP is the time period you can set for an
energy-saving temperature while you are
sleeping. (Again, lower heat or higher cool.
For more comfortable sleeping, some
people choose not to raise the cool temperature during the night.)

If no program is entered for the weekends, the
thermostat will operate on the weekday SLEEP
program all weekend.
Before programming, remove the clear plastic
overlay covering the display.

You will set one schedule for weekdays and
another for weekends, because your requirements will probably be different for each. Also,
during weekends, only the WAKE and SLEEP
time periods are available.

When pressing the keys, use the ball of your
finger or a soft pencil eraser. Using sharp
fingernails or pencil points can damage the
keypad.

Fill in the times and temperatures you desire
for weekdays and weekends. If you decide not
to program the thermostat, it will automatically
control heating at 68°F (20°C), and cooling at
78°F (26°C), 24 hours a day. Also, you do not
need to enter a time and temperature program
for all periods if your schedule does not require

If you make an error at any time during
programming, just press the Run Program key,
and continue again at the step where you left
off.
11

69-1120

Personal Programming Chart
Weekdays

Heating Program
Start Time

Heating Temperaturea

WAKE
LEAVE
RETURN
SLEEP
Weekendsb
WAKE
SLEEP
aThe temperatures cannot be set any higher than 88°F (31°C) or any lower than 45°F (7°C).
bIf you decide not to enter weekend programs, the SLEEP from the weekday program will copy to

the weekend schedule.

12

69-1120

Weekdays

Cooling Program
Start Time

Cooling Temperaturea

WAKE
LEAVE
RETURN
SLEEP
Weekendsb
WAKE
SLEEP
aThe temperatures cannot be set any higher than 88°F (31°C) or any lower than 45°F (7°C).
bIf you decide not to enter weekend programs, the SLEEP from the weekday program will copy to

the weekend schedule.
NOTE: If you decide not to program the thermostat, it will automatically control heating at 68°F
(20°C), and cooling at 78°F (26°C), 24 hours a day.
13

69-1120

This guide can be used for programming your new thermostat.
NOTE: Batteries are required for operation and programming. When inserting batteries, set
system switch to OFF. Remove battery door (on thermostat left side) using a coin at the
bottom. Follow instructions on pages 8 and 9. Also note that the label inside the battery
cover contains an abbreviated set of programming procedures for the thermostat.

Set Current Time/Day

Time
Clock/Day

To set time, press and release

once, press

until current time shows. To set day,

Time
Clock/Day

press and release

again, press

Run Program

until current day shows; then press

Heating Program

.

Weekday

With System switch at Heat, press and release
SET appear on display.

once. WAKE, MON FRI (Monday-Friday), and

14

69-1120

TEMP

Time

Use

to program WAKE time and

to program WAKE temperature for MON FRI

(Monday-Friday). Repeat sequence for LEAVE, RETURN, SLEEP.

Time

Weekend

Press

until SAT SUN (Saturday-Sunday), WAKE and SET appear on display. Use

to

TEMP

program WAKE time and

to program WAKE temperature for SAT SUN (Saturday-Sunday).
Run Program

Repeat sequence for SLEEP. Press and release

to start the program.

Cooling Program
With System switch at Cool, follow the same instructions as for the Heating Program.
Run Program

After programming, adjust the fan and system switches as desired. Press and release
the program.
15

to start
69-1120

A quick guide for operating or making changes follows.
NOTE: System switch must be set to Heat or Cool to perform the following:
TEMP

Temporarily Change temperature for current period only—Press

; temporary indicator will
Run Program

show on display and cancel itself at the next scheduled change; to cancel sooner, press

.

TEMP
Hold Temp

Hold a temperature indefinitely (such as if on vacation)—Press

and

; HOLD will appear

Run Program

on display; to cancel, press

.
Present Set

Check Current Temperature Setting—Press
pressing this will cancel your change.)

. (If using TEMPORARY CHANGE or HOLD,

16

69-1120

Weekday

Check Programs—Press

Weekend

,

repeatedly to see each time and temperature;

Run Program

then press

.
Weekday

Cancel Program—Press

,

Clear

Weekend

until program to cancel shows; then press

.

Usage

Check Usage — Press

for length of time heat or air conditioning has been running today since
Clear

midnight; press again for yesterday’s usage, press again for cumulative; press

to clear

Run Program

cumulative reading if desired; then press

.

Permanently Change a Program—Repeat steps under Heating Program or Cooling Program
(page 14 and 15) as applicable.
Run Program

Return to normal program or start program —Press

17

.

69-1120

Step 5. Adjust Fan Operation Switch, As Required
❑ The thermostat fan operation switch, labeled FUEL SWITCH (see illustration on page 19) is
factory-set in the F position. This is the correct setting for most systems. If your system is an
electric heat system, set the switch to E. The E setting will allow the fan to turn on immediately
with the heating or cooling in a system where the G terminal is connected.

Step 6. Adjust System On-Time, °F/°C, As Required
❑ The thermostat on-time is factory-set for a warm air, gas or oil heating system. If you are
installing it on another type of system, adjust the on-time accordingly by setting screws A and B
on the back of the thermostat. use the heating system table shown in the illustration (page 19)
as a guide. The system on-time should be optimized according to the type of system to minimize
room temperature swings. Setting the screw “out one turn” means turning the screw approximately 360° counterclockwise, or about one complete turn.
In the unlikely event that you want a longer furnace on-time, readjust screws A and/or B as follows:

18

69-1120

❑ The thermostat is set to read the temperature in degrees Fahrenheit. If readings are
desired in degrees Celsius, adjust screw C
out one turn, as shown in illustration.

First, turn in both screws completely, then
adjust for system type:
• Warm Air Furnace—Set at the Hot Water
setting (A—out one turn, B—leave in).
• Electric Furnace—Leave at the Warm Air
Furnace setting (A—leave in, B—leave in).

THERMOSTAT BACK

A

C

B

D

DISPLAY °F C–IN
DISPLAY °C C–OUT
1 TURN

NOTE: This thermostat does not have a
setting for steam/gravity air. Cycles
would not be long enough for accurate temperature control.

ADJUST SCREWS THROUGH HOLES
TO SELECT OPERATION DESIRED
FUEL SWITCH
HEATING SYSTEM
POSITION
F
WARM AIR A–IN
B–IN
FURNACE
F
HOT WATER A–OUT B–IN
BOILER
1 TURN
E
ELECTRIC A–IN
B–OUT
FURNACE
1 TURN

W

Y

G

FOR HIGH EFFICIENCY FURNACE (90%+ AFUE)
ADJUST: SCREW A–OUT ONE TURN
SCREW B–IN
FUEL SWITCH – F POSITION

FUEL SWITCH

IMPORTANT
When using a high efficiency furnace
such as a 90% or greater AFUE
(Average Fuel Utilization Efficiency)
unit, adjust screw A out one turn and
leave screw B in.

F

E

R

Rc

M8796

19

69-1120

Step 7. Mount Thermostat Mounting Plate
❑ Reposition mounting plate over holes,
pulling wires through wiring opening.
Loosely insert two mounting screws into
holes.
❑ Level for appearance only; thermostat will
function properly even when not level.
Tighten mounting screws.

❑ Position mounting plate on wall. Use level to
make sure mounting plate is level. Use a
pencil to mark the two mounting holes.
❑ Remove mounting plate from wall, and drill
3/16-inch holes in wall (if drywall) as
marked. For firmer material such as plaster
or wood, drill
WALL ANCHORS (2)
WIRES THROUGH
7/32-inch
WALL OPENING
holes.
Gently
WALL
tap
anchors
(provided)
into
drilled holes
MOUNTING
PLATE
until flush
with the wall.
MOUNTING
SCREWS (2)

LEVEL

M1714A

M1718

20

69-1120

❑ In 5-wire installations only, be sure to
remove the factory-installed jumper connecting terminals R and Rc.

Step 8. Wire Thermostat Terminals
NOTE: All wiring must comply with local
codes and ordinances. If unsure
about household wiring procedures,
call your local heating/air conditioning
contractor.

METHOD TO INCREASE WIRE LENGTH

Refer to masking tape labels you placed on
wires when you removed your old thermostat.

WIRE NUT SIZE FOR
TWO 18-GAUGE WIRES

WIRE
FROM
WALL

❑ Match the letter of your old thermostat wire
with the terminal of the corresponding letter
on the back of your new thermostat. Refer
to illustrations on pages 23 and 24. Hold the
thermostat as shown to minimize need for
wire extenders. If wires are still too short,
use wire connectors (purchased locally) to
extend wires. See figure for guidelines on
using wire extenders.

6 IN. (152 MM)
OF 18-GAUGE
THERMOSTAT
WIRE. MATCH
INSULATION
COLORS
OR MARK
WIRE ENDS.

M1715A

21

69-1120

❑ Loosen the terminal screws and slip each
wire beneath its matching terminal. See
illustration (lower right) for wire insertion
technique. securely tighten terminals.
❑ Plug the hole in the wall with insulation to
help prevent drafts from adversely affecting
thermostat operation.

M3002A

Y

G

22

W

END OF WIRE
VISIBLE HERE

JUMPER (FACTORYINSTALLED) REMOVE
IF 5-WIRE SYSTEM
Rc

INSERT
STRAIGHT
UNDER
SCREW HEAD

R

5/16 in.
(8 mm)
STRIP

M1712A

69-1120

4-WIRE HEAT/COOL (JUMPER INTACT)

2-WIRE HEAT-ONLY (JUMPER INTACT)
A

C

B

D

W

Y

A

C

B

D

JUMPER

G

W

Y

G

JUMPER

Rc

R

HEATING
RELAY OR
VALVE COIL

L1
(HOT)

R

HEATING
RELAY OR
VALVE COIL

COOLING
CONTACTOR
COIL

1

L2
1

Rc

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.

FAN
RELAY

L1
(HOT)
L2

M1709B

1

23

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
M1710B

69-1120

3-WIRE COOL-ONLY (JUMPER INTACT)

5-WIRE HEAT/COOL (JUMPER REMOVED)
A

C

B

D

W

Y

A

C

B

D

W

G

Y

G

JUMPER

R

HEATING
RELAY OR
VALVE COIL

R

Rc

COOLING
CONTACTOR
COIL

FAN
RELAY

COOLING
CONTACTOR
COIL

1

FAN
RELAY

1

L1
(HOT)

L1
(HOT)

L2

L2

1

Rc

L1
(HOT)
L2

1

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
M848A

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
M1711B

24

69-1120

Step 9. Mount The Thermostat
NOTE: To remove thermostat from wall, first pull out at bottom of thermostat, then remove top.
A. ENGAGE TABS AT TOP OF
THERMOSTAT AND SUBBASE.

B. PRESS LOWER EDGE
OF CASE TO LATCH.

C. SWING OPEN COVER TO
CHECK OPERATION.

AM
TU
LEAVE

Clock/Day

Time

TEMP

Run Progra

m

Weekday
Hold Temp
Weekend

Fan
Auto

Clear

Usage

On
Cool

Present Set

System
Off

Heat

M12494

25

69-1120

Step 10. Check Thermostat Operation After Programming and Installing
Heating
Do not check heating system
operation by jumpering thermostat
terminals, such as the gas valve,
zone valve, oil burner control at the
primary control. This will damage the
thermostat; Instead, jumper R and W
wires at the thermostat.

Cool

Off
Auto

Heat

Move the System switch to Heat
and the Fan switch to Auto.

On

TEMP

Press TEMP key until the setting is
about 10°F (6°C) above room
temperature. Heating should start
and the fan should run after a short
delay (immediately if fan operation
switch is set in E position).
Press TEMP key until setting is
about 10°F (6°C) below room
temperature. The heating equipment should shut off.

26

69-1120

Cooling
To avoid possible compressor damage, do not operate the cooling system
when outside temperature is below
50°F (10°C). See compressor manufacturer instructions for further
information.

Cool

Off

Auto

Heat

Move the System switch to Cool and
the Fan switch to Auto.

On

Press TEMP key until setting is about
10°F (6°C) below room temperature.
The cooling equipment and fan should
start.

TEMP

NOTE: When cooling setting is
changed, thermostat may
delay up to five minutes
before turning on the air
conditioner. This delay
protects the compressor.

Press TEMP key until the setting is
about 10°F (6°C) above room temperature. The cooling equipment and
fan should stop.
Cool

Off

Auto

Heat
On

27

Move the System switch to Off, with
the Fan switch still at Auto. The system
and fan should be off.

69-1120

Step 11. Set The Fan and System Switches
First set the Fan switch.

Fan Auto: Normal setting for most homes. A
single-speed fan will turn on automatically
with the air conditioner or furnace. A twospeed fan will usually run on high with the air
conditioner and on low with the furnace.

Auto

On

Auto

On

Exception: If Fan Operation Switch on back of
thermostat is set to E position (see page 16),
fan will operate with furnace only.
Fan On: The fan runs continuously. Use for
improved air circulation during special
occasions or for more efficient electronic air
cleaning. (In a heat-only system, fan will run
continuously only if fan relay is connected to
the thermostat.)

28

69-1120

Then set the System switch.

Cool: The thermostat controls your air conditioning system.
Off: Both the heating and air conditioning
systems are off.
Heat: The thermostat controls your heating
system.

29

Cool

Off

Heat

Cool

Off

Heat

Cool

Off

Heat

69-1120

Troubleshooting Guide
IF…
Display will not come on.

Temperature display will not go
lower than 45°F (7°C) or higher than
88°F (31°C) during programming.
Temperature change occurs at the
wrong times.

THEN…
q Set the System switch to Off. Remove batteries.

Insert backward for at least 5 seconds to reset
thermostat. Replace batteries correctly. Display
should come on.
q Make sure batteries are fresh and installed
correctly.
q Gently clean battery contacts using a soft pencil
eraser. Do not use anything abrasive on the clips.
q You have reached the temperature setting limit.
The setting range is 45°F to 88°F (7°C to 31°C).
q Check the program times for the period in

question. Be sure that AM and PM indications are
correct. Make sure the current day and time are
correct. Reprogram if necessary.
30

69-1120

Heating will not come on.

q Check that switch on thermostat is set to Heat.
q Check the system fuse or circuit breaker and

replace or reset if necessary.
q Check for correct wiring and good connections.
q Jumper wires R and W. If heat does not come on,

contact your heating dealer.
q If display is blank or says bAt Lo, install fresh

batteries.
q If temperature setting is higher than current

Cooling will not come on.

q
q
q
q
q

temperature, and the display says Heat, contact
Duracraft Consumer Services at 1-800-554-4558.
Check that switch on thermostat is set to Cool.
Check the system fuse or circuit breaker and
replace or reset if necessary.
Check for correct wiring and good connections.
Jumper wires Rc and Y. If cooling does not come
on, contact your cooling dealer.
If display is blank or says bAt Lo, install fresh
batteries.
31

69-1120

Cooling will not come on.
(continued)

q The thermostat has a built-in time delay on
q
q

q

The house is too warm or too cool.

q
q

cooling. Allow 5 to 10 minutes after changing the
setting before the air conditioner starts.
Make sure outdoor disconnect is energized (on).
If temperature setting is lower than current
temperature, and the display says Cool, move
system switch from Cool to Off for 10 minutes.
After 10 minutes, return switch to Cool position. If
air conditioner comes on, compressor may have
reached its high limit temperature protection and
shut down. If air conditioner does not come on
after the 10 minutes and the display says Cool,
contact Duracraft Consumer Services at 1-800554-4558.
If 2- or 4-wire installation, verify R-Rc jumper is
installed.
Press Present Set key to check the current
temperature setting.
If desired, change the temperature setting. See
page 16.
32

69-1120

SYSTEM ON indicator is lit, but no
heat is coming from the registers.

q Allow time for the furnace to heat up and the fan

to come on before checking for heat at the
register. (Check to make sure system on-time is
set correctly according to page 18 and 19.)
q Readjust system on-time according to
instructions on pages 18 and 19.

The furnace cycles too frequently or
the system cycle length is too short
or too long.
The thermostat's current setting does q Check that the wiring hole in the wall behind the
not match the display temperature to
wallplate has been plugged with insulation to
within ±1°.
prevent drafts that might adversely affect
thermostat operation.
q Be aware that it is normal for the current setting
and display temperature to differ on occasion.
q During recovery from setback or setup, setting
and display temperatures may differ for up to 30
minutes after recovery period.

33

69-1120

Incorrect room temperature showing
on thermostat display.

q Make sure the hole behind the thermostat is

plugged with insulation to help prevent drafts from
adversely affecting the thermostat operation.
q The thermostat is factory-calibrated and cannot
be adjusted.

Toll-free Customer Assistance
For all questions concerning this thermostat, please read and follow the instructions. If additional
assistance is needed, call Duracraft Consumer Services toll-free at 1-800-554-4558, Monday Friday, 7:00 a.m. - 5:30 p.m. Eastern time.
Before you call, please have the following information available—thermostat model number and
date code, kind of heating/cooling system (i.e., hot water, warm air, oil, gas, etc.), number of wires
connected to the thermostat.
NOTICE
This equipment is a Class B digital apparatus, which complies with Canadian Radio Interference
Regulations, CRC c.1374.
34

69-1120

Limited One-Year Warranty
Duracraft Corporation warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year
from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Duracraft shall repair or replace it (at Duracraft’s
option) within a reasonable period of time.
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or
(ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction, and mail it, postage prepaid, to the following
address:
Duracraft Corporation
Consumer Services
250 Turnpike Road
South borough, MA 01772
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Duracraft that the defect or malfunction was caused by damage which
occurred while the product was in the possession of a consumer.
Duracraft’s sole responsibility shall be to repair or replace the product within the terms stated above. DURACRAFT SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF
ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY,
EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this
limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY DURACRAFT MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some
states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state.
If you have any questions concerning this warranty, please write Duracraft Corporation, Consumer Services, 250 Turnpike Road, Southborough, MA 01772 or call 1-800-544-4558.
Monday-Friday, 7:00 a.m. to 5:30 p.m., Eastern time.

35

69-1120

TYPICAL ENERGY SAVINGS FOR REPRESENTATIVE CITIES IN THE U.S. AND CANADA
Savings for Once-A-Day
10°F (5°C) decrease

Savings for Twice-A-Day
10°F (5°C) decrease*

Savings for 5°F (3°)
summer increase

Approximate percentage of energy cost savings

30%
28%
26%
24%
22%
20%
18%
16%
14%
12%
10%
8%
6%
4%
2%

Minneapolis
St. Paul
Montreal
Ottawa
Toronto

Edmonton
Regina
Winnipeg

Calgary
Moncton
North Bay
Quebec
St. John's

Halifax

Vancouver

Buffalo
Cleveland
Milwaukee

Denver
Des Moines
Omaha
Salt Lake
City

Boston
Chicago
Detroit
Pittsburgh
Indianapolis

Cincinnati
Kansas City
St. Louis
Columbus

Louisville
New York
Philadelphia Portland
Wash., D C
Seattle

San
Francisco

Dallas
Atlanta

Los Angeles

*Based on 10°F (5°C) decrease—(5°F [3°C] decrease
gives approximately 55 percent of these savings).

® U.S. Registered Trademark
69-1120 7-97 R.T.

Printed in U.S.A. on recycled
paper containing at least 10%
36
post-consumer paper fibers.

San Diego

M2416A

69-1120



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Copy, Fill forms, Extract, Assemble, Print high-res
Create Date                     : 1997:07:11 09:04:33
Producer                        : Acrobat Distiller 3.0 for Power Macintosh
Subject                         : Owner's Guide
Creator                         : Adobe PageMaker 6.5
Title                           : 69-1120 - Programmable Thermostat by Duracraft
Author                          : H&BC Technical Communications
Modify Date                     : 2001:02:26 11:05:42-06:00
Page Count                      : 36
EXIF Metadata provided by EXIF.tools

Navigation menu