ChannelPlus H27XL Series 2
User Operating Instructions
Two Channel Central Heating and Hot Water Programmer

The ChannelPlus family of electronic programmers offer a range of advanced features
coupled with simplified ‘menu driven’ programming and designed to help save energy.
The Horstmann ChannelPlus H27XL series 2 is designed to give independent time control
over heating and hot water on a 7 day weekly programme.
Each channel offers up to 3 programmed On/Off operations per day
for each day of the week.
For day to day operation each channel has a manual 1 or 2 hour boost button
as well as an advance button to bring forward the next programmed operation.
The back lit display, automatic clock and menu driven programming are all features
designed to make the operation of the ChannelPlus H27XL as simple as possible to use.
All series 2 ChannelPlus programmers are direct replacements for earlier ChannelPlus models.

1

The ChannelPlus H27XL Series 2 Programmer –
The simple instructions contained in this user guide are designed to help with the
programming and operation of the unit. Most of the following instructions require the front
flap to be lowered. Please replace the flap when normal operation is required.
PRODUCT OVERVIEW - DETAIL SHOWN WITH THE FLAP LOWERED
1

2

4
3
5
6
8

7

10

12

11

9
13

1
2
3
4
5
6
7
8
9
10
11
12
13

2

Current time of day
Day of week and date
Channel Heading
Current Channel programme
Next On/Off time
Channel ON indicator
ADVANCE and ENTER button ILLUMINATED WHEN ACTIVE
ADVANCE and PLUS button
ILLUMINATED WHEN ACTIVE
BOOST and COPY button
ILLUMINATED WHEN ACTIVE
BOOST and MINUS button
Programme Select buttons (Coloured Blue)
SET button (Coloured Green)
Front Flap (Lowered)

Display Information
The ChannelPlus H27XL Series 2
programmer has a fully graphical, backlit display. In the normal run mode the
display is divided into two sections, each
section represents a controlled channel.
The information displayed will change
depending upon the settings made and
which mode you are in. During different
programming modes and/or setting
screens the current time, day/date,
holiday indicator will only appear when
necessary, this is to reduce confusion
during the programming process. This is
explained further in later sections of this
guide.

Time

Day
Date

Holiday
function
active

Channel
header

Channel/
Zone 1
status

Channel/
Zone 2
status

ACTIVATING THE BACK–LIT DISPLAY
The display will illuminate for
approximately 1 minute whenever a
button is pressed.
To illuminate the display for viewing
purposes only press the green menu
button under the front flap twice.
SETTING AND ADJUSTING
When setting or adjusting, the programmer will automatically return to the running mode
if no buttons are pressed for approx.1 minute.
If the setting or adjusting has not been finished, please start the procedure again.
TIME OF DAY
The ChannelPlus H27XL incorporates a factory set clock and calendar which means that no
adjustments should be necessary to the time of day and BST/GMT time changes take place
automatically.

3

Manual Overrides
BOOST FUNCTION - 1 OR 2 HOUR TEMPORARY OVERRIDE
The boost facility will allow the user to either activate a channel which is currently ‘OFF’ for
either 1 or 2 hours, or to extend a current ‘on’ period by 1 or 2 hours. To indicate the boost
being activated the ‘BOOST’ button under the selected channel will stay illuminated for the
duration of the boost/extension period. The display will also indicate the extension to the
time visually on the screen.

Press BOOST button
once for 1 hour of
hot water or central
heating



Press BOOST button
twice for 2 hours of
hot water or central
heating



Press BOOST button
a third time to
cancel the period
and return to the
normal programme

ADVANCE FUNCTION - BRINGS FORWARD THE NEXT ON OR OFF OPERATION
The advance facility will allow the user to either bring a channel ‘ON’ which is currently
‘OFF’ or switch a channel ’OFF’ which is currently ‘ON’. To indicate the advance feature
being activated the ‘ADVANCE’ button under the selected channel will stay illuminated
until the next programme switching time, the user display will change to also indicate the
status of the channel and the next switching time.

Press ADVANCE
button once to
move to the next
ON/OFF time

4



To cancel the advance
press the ADVANCE button
again. This will return
the unit to its normal
programme

Programme Override Facilities
With the ChannelPlus H27XL Series 2 programmer operating in the normal running mode it
is possible to alter the functionality of the programme on each individual channel.
The options include;
AUTO -

Programmer follows all programmed ‘ON’ and ‘OFF’ times.

ALL DAY - Channel operates from 1st ‘ON’ time until 3rd ’OFF’, ignoring all switching
			times in between. Useful for unexpected times of occupation or to
			maintain a constant temperature during an extended period.
ON - 		Channel will be constantly ‘ON’.
OFF 		
		

Channel will be constantly ‘OFF’, there is the ability to turn off heating
during summer without altering the programme times. 1 or 2 hour boost
still available.

All of the settings above will be permanent, i.e. unaffected by programme times, until
alteration by the user.
The diagram below illustrates how to alter the setting, it assumes that the channel is in the
AUTO mode to begin with. As both channels are totally independent it is possible to have
them set differently if necessary*.
Press SELECT
once.
Programme
goes from
AUTO to
ALL DAY



Press SELECT
again.
Programme
goes from
ON to OFF



Press SELECT
again.
Programme
goes from
OFF to AUTO








Channel
will operate
from first ON
until last OFF
period



Press SELECT
again.
Programme
goes from
ALL DAY to
ON

Channel
will be
continuously
ON

Channel
will be
continuously
OFF

Programme
will return
to normal
ON and OFF
times

ADJUSTING SETTINGS
When carrying out any alterations to the programmed times and settings the programmer
will return to its normal run mode in 1 minute if no adjustments are made in that time.
* It may not be possible to programme heating and hot water independently on certain systems.
5

Setting the Programme Times
The programme times have been preset as shown in the chart below.
Default Time settings - am/PM
1st ON

1st OFF

2nd ON

2nd OFF

3rd ON

3rd OFF

Mon - Fri

6.30AM

8.30AM

12.00PM

12.00PM

4.30PM

10.30PM

Sat/Sun

7.30AM

10.30AM

12.00PM

12.00PM

5.00PM

11.00PM

If any changes are required to the programme times please
complete the operation as described in the flowchart left.

Open cover



Use the ‘+’ and ‘-’
buttons to select
required setting
Channel 1 or 2





Use the ‘+’ and ‘-’
buttons to select
required day





Press the green
‘SET’ button

SAMPLE DISPLAYS

Press ‘ENTER’



SET WATER






Repeat process for
the 2nd and 3rd
time settings

SET HEATING
FOR
WEDNESDAYS




Press the green
‘SET’ button

If you require this
programme on any
other day of the
week use ‘+’ and
‘-’ buttons to select
day and copy


Press the green
‘SET’ button

6

SET DEFAULTS



Programme the
remaining days

SET HOLIDAY MODE

Press ‘ENTER’


Press ‘ENTER’

SET HEATING



Adjust OFF time



Press ‘ENTER’

Use the ‘+’ and ‘-’
buttons to adjust
required ON time

SETTING
HEATING - WEDNESDAYS
ON 06.30 ON 12.00 ON 16.30



Close cover

OFF 08.30 OFF 12.00 OFF 22.30

Setting the Holiday Mode
The holiday mode can be used to suspend the program function of the ChannelPlus
programmer, it can be set in advance of your departure date and for as long a period as
required. The holiday function operates from mid-day to mid-day, this means it can be
easily set to ensure your home is warm for your return. When the holiday mode has been
set a smiley face
will appear on the display. When the holiday mode is active only the
day/date and smiley face will be displayed.
Open cover

PLEASE NOTE: Any alteration to the current
time or date will cancel any Holiday
programme set.

Press the green
‘SET’ button



Use the ‘+’ and ‘-’
buttons to select
‘HOLIDAY MODE’

Use the ‘+’ and ‘-’
buttons to adjust
start date



Press ‘ENTER’



Use the ‘+’ and ‘-’
buttons to adjust
start month

Use the ‘+’ and ‘-’
buttons to adjust
start year





Press ‘ENTER’

Press ‘ENTER’



Repeat process for
end period

Press the green
‘SET’ button



Press ‘ENTER’



Close cover




SETTING HOLIDAY MODE
START AT MID-DAY ON
1 SEPT 2009
FINISH AT MID-DAY ON
21 SEPT 2009



SAMPLE DISPLAYS

Press ‘ENTER’



N.B. Do not use the holiday
programme when conditions are
such that frost damage to the heating
system is possible (unless a frost
protection thermostat is fitted to
your system).



To cancel an active holiday period please
press any of the Select buttons under the
front flap.



thurs 16 SEPT

Press the green
‘SET’ button

7

Adjusting Default Settings
The ChannelPlus H27XL Series 2 has a number of default settings which are normally
installed. These settings are designed to reduce the need for user intervention upon
installation of the programmer. However it is possible to customise the user display by
following the procedures in the following pages. The factory default normally installed are
illustrated below;

Time and Date

Clock Options

Headings

Time and calendar
are factory set

Time displayed in
24hr clock format

Channel heading set to
standard installation
ie. Hot Water and Heating



22.42



8






10.42

Options

Options

Options

The programmer has been
preset with the current
time and date during
manufacture.
No alteration should be
required to the time and
date. However, if any
modification is required
please refer to the
flowchart on page 9

24 hour
or
AM/PM

Heating/Water
Zones
Channels

Adjusting Time and Date - see note below
The ChannelPlus H27XL Series 2 programmer has been preset with the current time and
date during manufacture. No alteration should be required to the time and date, however
if any modification is required please refer to the flowchart below.
PLEASE NOTE: Any alteration to the current time or date
will cancel any Holiday programme set. It will also
cause any boost or advance operations to be cancelled.

Open cover




Use the ‘+’ and ‘-’
buttons to select
‘SET DEFAULTS’

Use the ‘+’ and ‘-’
buttons to adjust
‘TIME AND DATE’



Press ‘ENTER’



Use the ‘+’ and ‘-’
buttons to adjust
THE CURRENT TIME



Press the green
‘SET’ button


Press ‘ENTER’


Press ‘ENTER’



Use the ‘+’ and ‘-’
buttons to adjust
THE MONTH





Use the ‘+’ and ‘-’
buttons to adjust
THE DAY



Use the ‘+’ and ‘-’
buttons to adjust
THE YEAR

Press ‘ENTER’



Press the green
‘SET’ button





Press ‘ENTER’

Press ‘ENTER’

SET WATER
SET HEATING
SET HOLIDAY MODE
SET DEFAULTS

SET DEFAULTS
TIME AND DATE
CLOCK OPTIONS
HEADINGS

30 SEP 2009





Close cover

SAMPLE DISPLAYS

Press the green
‘SET’ button

TIME AND DATE
23.00
30 SEP 2009

9

Adjusting Clock Options

Use the ‘+’ and ‘-’
buttons to adjust
‘CLOCK OPTIONS’



buttons to select
‘SET DEFAULTS’

SAMPLE DISPLAYS



Press the green
‘SET’ button

The programmer has been preset to display the time in 24 hour
clock format, should you prefer AM/PM format then please use
the procedure given in the flowchart
opposite.
Use the ‘+’ and ‘-’



Open cover

SET WATER

Press ‘ENTER’

SET DEFAULTS




Press the green
‘SET’ button



Use the ‘+’ and ‘-’
buttons to adjust
24 HRS OR AM/PM

TIME AND DATE



Press ‘ENTER’

CLOCK OPTIONS

SET DEFAULTS

HEADINGS

Press ‘ENTER’


Press the green
‘SET’ button

SET HEATING
SET HOLIDAY MODE

CLOCK OPTIONS



Close cover

24 HOURS
AM/PM

General Information
BATTERY
The programmer is fitted with a non-rechargeable, non-serviceable long life battery,
which will maintain the clock and programmed time settings with the mains supply
disconnected.
THIS RESERVE SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF
THE UNIT.
During power interruptions the display will be blank.
SERVICE AND REPAIR
This programmer is NOT user serviceable. Please do not dismantle the unit. In the unlikely
event of a fault developing please refer to the RESETTING THE PROGRAMMER section right.
If this fails to resolve the problem please contact a local heating engineer or a qualified
electrician.
10

Adjusting Channel Headings

Use the ‘+’ and ‘-’
buttons to adjust
‘HEADINGS’



SET WATER
SET HEATING

Press ‘ENTER’

SET HOLIDAY MODE



Use the ‘+’ and ‘-’
buttons to adjust
HEATING/WATER
ZONES OR CHANNELS

TIME AND DATE





Press the green
‘SET’ button

SAMPLE DISPLAYS

SET DEFAULTS


Press ‘ENTER’

buttons to select
‘SET DEFAULTS’



Press the green
‘SET’ button

The programmer has been preset to display the channel heading
as ‘Heating and Hot Water’, should you require either the ‘Zone’
or ‘Channel’ options then please follow
the flowchart opposite.
Use the ‘+’ and ‘-’



Open cover

CLOCK OPTIONS

SET DEFAULTS

HEADINGS

Press ‘ENTER’



HEADINGS

Press the green
‘SET’ button

HEATING/WATER



Close cover

ZONES
CHANNELS

General Information
RESETTING THE CHANNELPLUS H27XL SERIES 2
Electronic equipment can in some circumstances be affected by electrical interference.
If the display becomes frozen or scrambled; or if you wish to revert back to the default
settings please use the following procedure:
RESET PROCEDURE
PLEASE NOTE: Using this procedure will restore the ChannelPlus to the original factory
programme settings, the time setting will remain correct.
ADVANCE


RESET

BOOST
SELECT



Lower the front flap of the unit. On the right
hand Channel press the ADVANCE (Enter)
and SELECT (Blue) buttons together, then
release and the programmer will return to
the preset factory settings.

11

What is a programmer?
... an explantion for householders.
Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central
heating and domestic hot water on and off at the same time; while others allow the
domestic hot water and heating to come on and go off at different times.
Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle. On some programmers you
must also set whether you want the heating and hot water to run continuously, run under
the chosen ‘On’ and ‘Off’ heating periods, or be permanently off.
The time on the programmer must be correct. Some types have to be adjusted in Spring
and Autumn at the changes between Greenwich Mean Time and British Summer Time.
You may be able to temporarily adjust the heating programme, for example, ‘Override’,
‘Advance’ or ‘Boost’. These are explained in the manufacturer’s instructions.
The heating will not work if the room thermostat has switched the heating off. And, if
you have a hot-water cylinder, the water heating will not work if the cylinder thermostat
detects that the hot water has reached the correct temperature.

Email: sales@horstmann.co.uk
Website: www.horstmann.co.uk
Horstmann Controls Limited, Bristol BS4 1UP
12

Leaflet number P82692 – Issue 3



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Page Count                      : 12
Create Date                     : 2013:03:30 20:42:22
Creator                         : Google
Producer                        : Google
EXIF Metadata provided by EXIF.tools

Navigation menu