Filtration UHP Zero Air and Hydrogen Generators for Fuel Gas Bulletin M1084A Distr. WITH E L B VAILA RRANTY! A W NO R WA A E Y 2- ChromGas TM UHP Zero Air and Hydrogen Generators Bulletin M1084A Distr. The Parker Hannifin Filtration Group assures: Hydraulic, Lubrication & Coolant Filtration High-performance filtration systems for production machinery in industrial, mobile and military/ marine. ■ Consistent quality ■ Technical innovation ■ Premier customer service Compressed Air/Gas Filtration and Separation Parker’s technical resources provide the right filtration technologies that conform to your requirements. That’s why thousands of manufacturers and equipment users around the world rely on Parker Filtration products and people. Complete line of compressed air/gas filtration products and gas generators for many industrial and laboratory applications. Process & Chemical Fluid Filtration Liquid filtration systems for beverage, chemical and food processing; cosmetic, paint, water treatment; photoprocessing; and micro-chip fabrication. Worldwide Sales and Service Parker operates sales and service centers in major industrial areas worldwide. Call 1-800-C-PARKER for more information and for a synopsis of our Filtration Technology Textbook. Fuel Conditioning & Filtration Parker air, fuel and oil filtration systems provide quality protection for engines operating in any environment, anywhere in the world. Legal Notifications ! WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice. Offer of Sale The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the "Offer of Sale". © Copyright 1995, Parker Hannifin Corporation, All Rights Reserved. Filtration Filtration Parker Hannifin Corporation Parker Hannifin Corporation Filtrationbyand Separation Division Distributed Chrom Tech, Inc. MA • 1-800-343-4048 AppleTewksbury, Valley,MN • 800/822-5242 www.parkegfr.com/balston UHP Zero Air and Hydrogen Generators Ultra High Purity Hydrogen Generators Bulletin M1084A Distr. from ChromGas TM The most complete line of research grade purity hydrogen generators: Model 9090: 0 to 90 cc/minute Model 9150: 0 to 160 cc/minute Model 9200: 0 to 250 cc/minute Model 9400: 0 to 500 cc/minute Model 9800: 0 to 1200 cc/minute Delivery pressure: selectable 0-100 psig Hydrogen purity: 99.99999% Hydrogen On Demand, Up to 1200 cc/minute ChromGas ultra high purity (UHP) hydrogen generators from Parker are designed as hazard-free alternatives to high pressure gas cylinders. They can be used with any instrumentation requiring high purity hydrogen — anywhere a standard electrical supply is available. Deionized water is all that is required to generate hydrogen for weeks of continuous operation. With an output capacity of up to 1200 cc/minute, one generator can now supply 99.99999% pure carrier gas to several GC's, and fuel gas to 12 FID's. Based on cylinder gas savings alone, a ChromGas hydrogen generator pays for itself in less than a year. (OSHA - 1910.103). Most importantly, they are the only hydrogen generators certified for laboratory use by CSA, UL and IEC 1010. 99.99999% Pure The exclusive proton exchange membrane has been complemented with a scrubber to generate 99.99999% pure hydrogen. That’s why Parker hydrogen generators are recommended by GC and column manufacturers. Parker's Chromgas proprietary replaceable desiccant cartridge provides fuel grade purity 99.9995% and ensures consistent reproducible results. The model 9800 comes standard with a palladium purifier module to reach levels of gas purity up to 99.99999%. Certified Safety Parker's hydrogen generators use an exclusive Proton Exchange Membrane to produce UHP hydrogen on demand. Only 100 mL is stored in the system at any time and at low pressure. A built-in sensing circuit shuts the generator down if a hydrogen leak is detected. Proven Technology Parker’s exclusive Proton Exchange electrolyte Electrolyzer eliminates the use of liquid electrolytes with hydrogen generators. Proven in over 20,000 GC installations worldwide, Parker’s generators are the most reliable hydrogen generators on the market. Maintenance requires only a few moments per year — no inconvenient, extended downtime. Simply change the deionizer bag every six months and the desiccant cartridge whenever it turns beige. And if contaminated water or low water level is detected, the system activates a warning light and shuts off the generator — avoiding damage to the electrolytic cell. Proton Exchange Electrolyzers are also extensively used in Navy submarines and NASA supplemental fuel systems. This reliable, high quality hydrogen generation technology is also being considered to fuel the Ultra Low Emission and Zero Emission Vehicles (ULEV/ZEV) of the future. That’s why Parker hydrogen generators meet the strict, safety guidelines of the National Fire Protection Agency (NFPA) and the regulations of the Occupational Safety and Health Association 1 Filtration Parker Hannifin Corporation Distributed By Chrom Tech, Inc. Apple Valley, MN • 800/822-5242 • 952/431-6345 fax www.chromtech.com • sales@chromtech.com Bulletin M1084A Distr. UHP Zero Air and Hydrogen Generators If You Want Safe Hydrogen, Get a Safe Generator PROTON EXCHANGE MEMBRANE (PEM) CELL Built to International Standards Parker Produced and supported by an ISO 9001 registered organization, Parker’s hydrogen generators are the first built to meet the toughest laboratory standards in the world: CSA, UL, and IEC 1010. Meet OSHA and NFPA Requirements All Parker hydrogen generators meet NFPA requirements and OSHA 1910.103 regulations governing the storage of hydrogen. 2 Filtration Parker Hannifin Corporation Distributed By Chrom Tech, Inc. Apple Valley, MN • 800/822-5242 • 952/431-6345 fax www.chromtech.com • sales@chromtech.com UHP Zero Air and Hydrogen Generators The Parker ChromGas Advantage Bulletin M1084A Distr. 99.99999% Pure Hydrogen as Carrier Gas Until now, running your gas chromatograph on hydrogen carrier gas was a trade-off: excellent results versus high pressure gas cylinders in the laboratory. Not any longer. The availability of Parker’s high capacity, 100 psi pressure, 99.99999% pure hydrogen means gas chromatographers can exploit the benefits of using hydrogen as carrier gas. Parker has a system to fit your lab with four different models with flow capacities ranging from 90 to 1200 cc/ minute. Each system provides research grade hydrogen to give you superior results for high speed, micro bore capillary GC applications. UHP Zero Air for GC-FID Combine the hydrogen generator with Parker’s UHP zero air generator and there is no longer a need to use cylinder gas in your GC laboratory. Now you can exploit the benefits of hydrogen carrier gas without using hazardous cylinders. A continuous, uninterrupted supply of pure gas also means predictable GC performance, less recalibrations and improved baseline stability. That’s why major GC and gas suppliers are recommending Parker’s ChromGas UHP gas generators. Typical payback periods are less than one year. * Data provided courtesy of Air Products and Chemicals, Inc. 3 Filtration Parker Hannifin Corporation Distributed By Chrom Tech, Inc. Apple Valley, MN • 800/822-5242 • 952/431-6345 fax www.chromtech.com • sales@chromtech.com UHP Zero Air and Hydrogen Generators UHP Zero Air Generator Bulletin M1084A Distr. Hydrocarbon-Free Air Generators Parker’s zero air generators produce a continuous flow of ultra pure zero grade air from an existing compressed air supply. When used in conjunction with a Parker hydrogen generator, gas chromatographers can totally automate and control their gas supply for GC-FID’s. The UHP zero air generator reduces the total hydrocarbon content (THC) to less than 0.1 ppm measured as methane. The generator produces lower, more stable baselines than cylinders, thus significantly enhancing the sensitivity of GC-FID analysis. Simple Now you can convert house air or compressed air into UHP zero air in just three easy steps: 1) supply standard AC electrical power to the system; 2) wait just a few minutes to warm up the catalytic converter — an operating light indicates when the system is ready; and 3) supply air flow and begin using your instrument. The zero air generator produces gas equivalent to UHP zero air cylinder gas at a fraction of the cost. An inlet 0.5 micron coalescing filter removes particles, oil and water from the air supply. Hydrocarbons are removed when the compressed air is passed over a convertor containing a heated catalyst. And, after the air is cooled, a 0.01 micron membrane filter is used to remove any residual particles. Cost Effective Parker’s zero air generators produce up to 3500 cc/minute of UHP zero air, at low pressures of 2 to 125 psig — on demand. They afford the advantage of on-site gas generation. In gas savings alone, a UHP zero air generator can pay for itself in as little as six months of operation. In addition to cost savings, there are valuable time savings. Now you can eliminate changing gas cylinders and save the time required to recalibrate your instrument after each cylinder change. Small, compact units: Model 1000: 0-1000 cc/minute Model 3500: 0-3500 cc/minute Delivery pressure: 2 to 125 psig Low, Stable Baselines ChromGas generators provide years of stable and reliable UHP zero air supply and GC operation. Unlike other zero air generators, Parker’s 3500 UHP zero air generators have a built-in electronic control to maintain the convertor and its optimum operating temperature. Line voltage and ambient temperature variations will not affect the absolute temperature of the heated catalyst. The quality of the produced hydrocarbonfree air is maintained for years. This worry-free operation will also give you years of predictable GC performance. UHP zero air generators increase the accuracy of the analysis by producing a cleaner baseline readout. They also significantly reduce the cleaning requirement of the FID. System maintenance is minimal. We recommend changing the inlet and outlet filters every six months. Parker ChromGas Zero Air Generators (ZAG) are temperature compensated to maintain consistent low THC impurity levels. The graph illustrates the performance of the model 3500. THC levels are stable over time, shortly after powering up the system. 4 Filtration Parker Hannifin Corporation Distributed By Chrom Tech, Inc. Apple Valley, MN • 800/822-5242 • 952/431-6345 fax www.chromtech.com • sales@chromtech.com UHP Zero Air and Hydrogen Generators Worldwide Support and Service Bulletin M1084A Distr. Quality products by Parker Hannifin are made in the a U.S.A., and each gas generator incorporates superior workmanship and the best quality components available. Purity: 99.99999% pure clean hydrogen gas. Oxygen <1 ppm Moisture <1 ppm Hydrocarbons/halocarbons, 1 ppb Weight: Model 3500: 20 lbs (9.1 kg) Model 1000: 11 lbs (5 kg) Today, with over 20,000 gas generators in routine use, we stand ready to handle any support situation a customer anywhere in the world may encounter. Delivery Pressure: 2 to 30 psig +3% 30 to 100 psig +2% Flow Rates: Model 3500: 3500 cc/minute Model 1000: 1000 cc/minute Pressure Control: 5 to 20 psig +0.5% 20 to 100 psig +0.2% Delivery Pressure: Inlet air pressure: 2 to 125 psig. Pressure drop at maximum flow rate: 5 psig Flow rate pressure stabilization: < 2 minute Specifications Hydrogen Generator 9000 Series Electrical: 117 Vac/234 Vac Dimensions: Model 9090, 9150, 9200 and 9400: Height: 14.75 inches (37.8 cm) Width: 13 inches (33.3 cm) Depth: 14 inches (35.9 cm) Model 9800: Height: 14.5 inches (37.2 cm) Width: 13 inches (33.3 cm) Depth: 17 inches (43.6 cm) Weight: 40 lbs (18 kg) dry Flow Rates: Model 9090: 90 cc/minute Model 9150: 160 cc/minute Model 9200: 250 cc/minute Model 9400: 500 cc/minute Model 9800: 1200 cc/minute Zero Air Generator Series Electrical: 60 Hz system: Voltage (Vac) 100 to 125 Amperage (Amps) 1.0 Fuse (Amps) 1.5 Wattage (Watts) 100 50 Hz system: Voltage (Vac) 200 to 250 Amperage (Amps) 0.5 Fuse (Amps) 0.8 Wattage (Watts) 100 Dimensions: Model 3500: Height: 12 inches (29.2 cm) Width: 6.75 inches (17.8 cm) Depth: 15 inches (39.4 cm) Model 1000: Height: 9.75 inches (25 cm) Width: 5.75 inches (14.7 cm) Depth: 12 inches (30.8 cm) Suggested Replacement Parts: Model 1647727: Dessicant cartridge (1 each) Model 7601132: Deionizer bags (2 each) 5 Filtration Gas Characteristics: Outlet THC as methane: <0.1 ppm Maximum inlet THC: 100 ppm Maximum inlet air temperature: 104 oF (40 oC) Overheat shutdown: yes Start-up time for maximum THC purity: 30 minutes without air flow; 45 minutes with air flow An optional charcoal filter is needed if compounds that contain sulphur or halocarbons are present in the source air. This eliminates the possibility of contamination to the catalyst or reduction in the efficiency of the catalyst. Free Literature Performance documentation and application notes produced by GC experts illustrate how Parker's gas generators will enhance the performance and accuracy of your GC systems. Parker Hannifin Corporation Distributed By Chrom Tech, Inc. Apple Valley, MN • 800/822-5242 • 952/431-6345 fax www.chromtech.com • sales@chromtech.com Bulletin M1084A Distr. UHP Zero Air and Hydrogen Generators Filtration Group Technical Sales & Service Locations Filtration and Separation Division Distributed By Chrom Tech, Inc. Apple Valley, MN 55124 Phone: 800-822-5242 Fax: 952-431-6345 Parker Worldwide Sales Offices Contact Parker’s worldwide service and distribution network by calling: Filter Division Europe Churwell Vale Shaw Cross Business Park Dewsbury, England WF12 7RD Phone: +44 1924 487000 Fax: +44 1924 487060 Argentina ...................... +54 1 752 4129 Australia ....................... +61 2 634 7777 Austria ...................... +43 2622 23501 5 Belgium ........................ +32 2 762 1800 Brazil .......................... +55 11 847 1222 Canada ....................... 1-800-272-7537 Central & South America/Caribbean ..... 1-305-470-8800 China ........................ +86 21 6445 9339 P.O. Box 3 Burrell Way Thetford, Norfolk IP24 3RT England Phone: +44 1842 754251 Fax: +44 1842 753702 Fin-31700 Urjala As., Finland Phone: +358 3 54 100 Fax: +358 3 54 10100 Hydraulic Filter Division 16810 Fulton County Road #2 Metamora, OH 43540 Phone: (419) 644-4311 Fax: (419) 644-6205 1273 N. Church Road Moorestown, NJ 08057 Phone: (856) 866-9002 Fax: (856) 866-9112 Process Filtration Division 1515 W. South Street Lebanon, IN 46052 Phone: (765) 482-3900 Fax: (765) 482-8410 State Road 66 Tell City, IN 47856 Phone: (812) 547-2371 Fax: (812) 547-2380 Racor Division 3400 Finch Road P.O. Box 3208 Modesto, CA 95353 Phone: (800) 344-3286 Phone: (209) 521-7860 Fax: (209) 529-3278 Route #3 Box 9 Henryetta, OK 74437 Phone: (800) 451-7299 Phone: (918) 652-4481 Fax: (918) 652-8882 302 Parker Dr. Beaufort, SC 29902 Phone: (843) 846-3200 Fax: (843) 846-3231 Czech Republic ..... (420) (2) 830 85 22 Denmark ........................ +45 43 541133 Finland ........................... +358 3 54 100 France ........................ +33 4 50 258025 Germany ..................... +49 3727 90991 Hong Kong .................. +852 2428 8008 Teollisuustie 2 89400 Hyrynsalmi Finland Phone: +358 8 6532500 Fax: +358 8 6532520 Hungary ....................... +36 1 25 22 539 India ........................... +91 22 577 1671 Italy .................................. +39 2 451921 Japan ......................... +81 45 861 3811 Jordan ........................ (962) (6) 810679 Korea Choongnam ... +82 417 583 1410 Oude Kerkstraat 4 P.O. Box 258 4870 AG Etten-Leur The Netherlands Phone: +31 76 508 53 04 Fax: +31 76 508 53 12 P.O. Box 749 Maidstone England ME16 OXY Phone: +44 1622 686611 Fax: +44 1622 695322 Filtration Group Headquarters 6035 Parkland Blvd. Cleveland, OH 44124-4141 Phone: (216) 896-3000 Fax: (216) 896-4021 http://www.parker.com/filtration Parker Hannifin Ind. e Com. Ltda. Filter Division AV Getulio Vargas, 1331/1333 12300-000 Jacarei, SP Brazil Phone: +55 12 355 1000 Fax: +55 12 355 1010 Parker Hannifin Korea Limited 902 Dae Heung Bldg. 648-23 Yeoksam-dong Kangnam-ku, Seoul, Korea 135-080 Phone: +82 2 561 0414 Fax: +82 2 556 8187 Filtration Poland ......................... +48 22 8634942 Singapore ........................ +65 261 5233 South Africa ................ +27 11 3927280 Spain ............................. +34 1 6757300 Sweden ........................ +46 8 760 2960 Switzerland .............. +41 (81) 2 526676 Taiwan ...................... +886 2 8787 3780 Thailand ........................ +662 693 3304 United Arab Emirates ..... +971 2 788587 United Kingdom ........ +44 1924 487000 USA ............................. 1-800-272-7537 Venezuela .................... +58 2 238 5422 Note: The (+) sign in front of the country code indicates that you may need to dial an additional prefix. Member of Filtration Korea Kyoungnam ... +82 523 389 0100 Mexico ......................... 1-800-272-7537 Netherlands ................... +31 541 58500 New Zealand ................ +64 9 573 1523 Norway ........................ +47 64 86 77 60 Parker Hannifin Corporation Distributed By Chrom Tech, Inc. P.O. Box 240248 Apple Valley, MN 55124 Phone: 800-822-5242 or 952/431-6000 Fax: 952-431-6345 www.chromtech.com • sales@chromtech.com Parker Hannifin Corporation Bulletin M1084A Distr. USA Filtration and Separation Division Reprinted July 2001 Tewksbury, MA • 1-800-343-4048 www.parker.com/balston
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Create Date : 2001:07:24 16:06:30 Producer : Acrobat Distiller 4.0 for Macintosh Modify Date : 2002:10:29 10:37:18-06:00 Page Count : 8EXIF Metadata provided by EXIF.tools