000.021_1206c14f8835313c[1] INSTAFLEX PRODUCT RANGE

User Manual: INSTAFLEX PRODUCT RANGE

Open the PDF directly: View PDF PDF.
Page Count: 75

INSTAFLEX
Product Range
2009
PB Polybutylene
PE Polyethylene
PP Polypropylene
d Pipeoutsidediameter
EPDM Ethylenepropylenerubber
s Wallthicknessofthepipe
dCu Copperpipeoutsidediameter
DN Nominalbore
Ø Diameter
LK Holecircle
SW Dimensionacrossflats(A/F)
G Pipethread,notpressuretightin
 thethread(withflatseat)toISO
 228
R Tapermalethread,pressuretight
 inthethreadtoISO7
Rp Parallelfemalethread,pressure
 tightinthethreadtoISO7
M MetricthreadtoISO261
m Meter
SP Itemsperstandardpack
g Gram
Explanation of signs
Dimensions
Alldimensionsaregiveninmmandare
intendedasnominaloraveragesizes.Subject
toalterationresultingfrommodificationsin
design.
For compressed air applications with air containing mineral oil, EPDM
gaskets must be replaced by NBR gaskets.
This mainly concerns unions and flange connections.
Note: For systems containing oil, INSTAFLEX is not suitable.
NBR gaskets are not contained in this Product Range. Please contact the GF
sales consultant or sales support office assigned to your
sales area.
GF and INSTAFLEX areregistered trademarks.
Alwaysprotectplasticpipesandfittingsfromexternalinfluences.
Directsunlightandtheeffectsofimpactandpressureshoudbe
avoided.Alwaysleavethepipesandfittingsinitspackaginguntilreadytouse.
Donotstoreoutside.
General Information
!
n.b. inch o.d. metric n.b. metric
3/8 16 10
1/2 20 15
3/4 25 20
 1 32 25
1
1/4 40 32
1
1/2 50 40
 2 63 50
2
1/2 75 65
 3 90 80
 4 110 100
 4 125 110
 5 140 125
 6 160 150
 6 200 180
 8 225 200
Inch - Metric Equivalents
1
INSTAFLEX
The modern versatile piping system
AfullrangeofpipeandfittingsmakestheINSTAFLEXsystemhighlyversatile.
Allowingprefabricationandbeing
lightweightmaketheinstallationof
anINSTAFLEXsystemhighlycost
effective.
2
What is INSTAFLEX?
The versatile pressure piping system
for building services
For use on:
l Hot & cold water services
l Heating systems
l Chilled water
l Compressed airlines
TheINSTAFLEXsystemhasbeen
designedforuseasacomplete
buildingservicespipingsystemwhich
providesasolutiontotheproblems
facedbytraditionalmaterialsnamely:
l No corrosion
l No encrustation/limescale
l No noise emmission
l Long service life
l High flexibility
l Fast assembly
l Lightweight
Launchedin1980intomainland
EuropeandintotheUKin1995this
systemhasprovidedinstallersand
designerswithaflexiblesystem
whichmeetsthestringentdemands
ofmodernbuildingdesignand
construction.
Material
Manufacturedfrompolybutylene(PB),
ahighperformanceplasticsmaterial,
whichwasspecificallydevelopedfor
useinpipingsystemsforpotable
water.Itsinherentcharachertistics
makeitidealforthispurposeandfor
otherbuildingservicesapplications.
Range
Afullrangeofpipeandfittingsare
availablewithadaptorstojoinonto
otherpipingsystemcomponents.
l Pipe & fittings 16 -225mm
l Pipe-in-sleeve
l Accessories & jointing
equipment
l Valves
Jointing & installation
TheINSTAFLEXsystemutilisesthree
complimentaryjointingtechniques:
l socket fusion
l electrofusion
l compression fittings
l butt fusion
Eachofwhichhaveadvantagesdepending
ontheinstallationinquestion.Most
installationstendtoincorporatemorethan
onetypeofjointingmethod.
Duetotheflexibilityofthesystemandthe
material'slightweight,significantsavings
canbemadeoninstallationtimeand
costs.
Technical advice & support
GeorgeFischer'sexpertiseandtechnical
knowledgeinthepipingsystemfieldis
recognisedworldwide.Inordertoassist
designersandinstallersintheoptimum
useoftheINSTAFLEXsystemthefollowing
supportisavailable:
l On-site support & advice
l Design take-offs
l Certificated jointing training courses
l Technical support
l CAD
l Custom products
l Off site prefabrication
3
Polybutyleneisathermoplasticfrom
thepolyolefinefamily.
Itisasemi-crystallinematerial.
Itsdensityisintherangeofother
thermoplasticssuchasPEorPP.It
hasgoodmechanicalpropertiesand
chemicalresistancemakingpolybuty-
leneanimportantmaterialforpiping
systems.
PBiscreatedbypolymerizingbutylene
(C4H8)andis,therefore,anecologicaly
safehydrocarbonproduct.
Thematerialwhichweuse,maybe
usedwithfoodstuffsduetoitssafe
stabilizingagent.Thefittingsandpipes
areodourlessandtastelessaswellas
physiologicallysafe.Itisperfectfor
useindrinkingwaterinstallations.
LikePEandPP,PBbelongstothe
groupofco-valentmaterials,whose
surfacesdonotswellandarenot
soluble.Solventcementingis,
therefore,notpossiblewithoutspecial
surfacetreatment.PBis,however,
easilyfused.Compression,socket
fusionandelectrofusionjointingcan
beused.
Flexibility,evenatlowtemperatures,
highthermalstabilitymake
polybutyleneamodernmaterial.
Notonlyforhotandcoldwater
distributionbutalsoinindustrial
applicationsandcompressedair.
GFareabletosupplymetricsocket,
buttandelectrofusionpipe,fittings
andvalvesaswellasmechanical
jointsinthefollowingsizerange.
socketfusion16mm-110mmo.d.
electrofusion16mm-225mmo.d.
buttfusion125mm-225mmo.d.

Property PB Unit
Density 0.93  g/cm3
MeltflowindexMFI@90/5 0.4  g/@0min
Yieldstrength 17  N/mm2
Elongationatfracture >125  %
Bending-creepmodulus(@min.) 800  N/mm2
Impactstrength23°C nofailure  mJ/mm2
Impactstrength20°C 40  mJ/mm2
Crystallinefusiontemperature 0.013  °C
Coefficientoflinearexpansion 0.13  mm/m°C
Thermalconductivityat20°C 0.32  W/m.K
Surfaceresistance 0.007 W
Normalworkingtemperaturerange -15to95  °C
Properties of Polybutylene
Testing
speed
@25 mm/min
Thephysicalvaluesshowninthetable
belowaretobetreatedasguidevalues.
What is Polybutylene (PB)?
4
Temperature/Pressure rating
TheGFINSTAFLEXsystemis
manufacturedfrompolybutylene
whichisathermoplasticmaterial.As
thenamethermoplasticsuggests,it
isaffectedbytemperature.Whenthe
temperatureoftheliquidinthepipeline
risesthematerialwillsoftenandits
abilitytowithstandpressurereduces
correspondingly.Tocalculatethe
pressureratingatanygiventemperature
thewellknown"vessel"formulais
usedinconjunctionwiththelongterm
regressioncurvesofthematerial.
SFfor non-dangerous
liquids= 1.5
SFfor dangerous
liquids=2.0
Designlife 50 years.
SafetyFactor 1.5
Note:
Size16 & 20mm
is25 bar
25to 110mm is
16bar.
Temperature/Pressure chart
P= σx20xs
SFx(d-s)
SF σx20xs
Px(d-s)
or
where P=pressureinbar
σ=hoopstressofmaterialat
 anygiventemp.inMPa
 s=pipewallthicknessinmm
 d=pipeo.d.inmm
 SF=safetyfactor
Example
Whatisthemaximumpressurefora
110mmpipecarryingwaterat70°C
withaworkinglifeof50years
s=for110mmINSTAFLEXpipe
is 10mm
SF=1.5
d=7.5MPatakenfromlongterm 
regressioncurveopposite.
P= σx20xs
SFx(d-s)
P= 7.5x20x10
1.5x(110-10)
P = 10 bar
26
24
22
20
18
16
14
12
10
8
6
4
2
0
maximum allowable pressure rating in bar
Temperature in °C
0 10 20 30 40 50 60 70 80 90 100
16 & 20mm o.d. pipe
25 & 110mm o.d. pipe
5
INSTAFLEX (PB) Specification
General
ThePolybutylene systemshallbe suppliedby
GeorgeFischer, Telephone024 76535535,
Fax 02476 530450.(Availablefrom appointed
distributors,contact theabovefor your
nearestdistributor.)
Requirementsspecific tothe designof PB
pipeworksystemsarecontainedin this
section.
Polybutylene(PB) pipeworkfittings shallbe
usedfor theconveyanceof heatingLTHW and
potablecoldwater,foruseinalldomestic
coldwaterservices, chilledwater, hotwater
servicesand compressedair shouldcomply
withthe requirements specifiedin BS7291
(Parts1 and2) class‘S’; DIN16968/DIN 16969
orEN ISO15876-1.
Thewholeof thePB pipeworkinstallations
shouldbe testedin accordancewiththe
requirements asset outin BSCode of
Practice312: andinstalledin accordance
withBS6700 andthe relevantmanufacturer’s
instructions.
Careshould beexercised whilstoff-loading,
storing,transportingabout thesite andwhilst
installingthe pipeworkand fittingsto ensure
thatno accidentaldamageoccurs tothe
pipeworkor fittings.Also, thepipeworkand
fittingsshould notbe stored where they
maybe exposedto theeffects ofultra violet
radiationincluding daylight.
Pipes
AllPB pipingshould betoBS7291: Part1&2;
DIN16968/DIN 16969or ENISO15876-2.
Pipe Fittings and Valves
Unlessspecified otherwise,all associatedpipe
fittings(viz. Manifolds,unions andflanges)
shouldbe ofPB manufacturedgenerallyin
accordancewith BS7291: Parts1 and2 and
brassfittings manufactured generallyin
accordancewith BS864, Part2; orEN ISO
15876-3and befullycompatiblewith the
pipesystem theyareto beinstalled with.
Valvesfor PBpipeworkshould befully
compatible withthe pipeworksystem
towhich theyaretobe connected,
comprisingvariously:
(i)PB gatevalvesfor pipesizes upto and
including63mm outsidediameter, allowing
bi-directionalflowwith direct sealingof
slidein valvebody operatingat 90°to
directionof pumpflowwith nonraising
valvesspindle.
(ii)PVC-C ballvalves, forpipe sizesup
toand including63mm outsidediameter,
meetingthe resistance topressure
requirement ofDIN 3441,allowing
bi-directionalflowwith floatingball, and
complete withdoublesocketdisconnecting
endsand removableseals.
(iii)PVDF flangedbutterflyvalves, for
pipesizes over63mmoutsidediameter,
allowingbi-directionalflow,or overall
dimensionscomplyingwith DIN3441:
Part5 orISO 7508and havingvalve body
holestoallowconnectiontoflangesdrilled
inaccordancewith BS8063: Part4, ISO
2536or BS10; Table Dor E.
(iv)Brass valves shouldbe suitable for
connectionwith PBpipe directly,or
withadaptors toflanged orthreaded
connectors.
(v)Onlypipe cleaner andsealant
specifically approvedbythepipeand
fittingsmanufacturershould beused.
Theabovevalvesshouldbeusedfor
balancingand regulationspurposes.
Unlessotherwise indicatedon the
drawings,draw-offisolatingvalvesshould
beof approvedconstruction with
femalethreaded endssuitableforPB
threadedadaptors.
6
Selection of PB Pipe Systems
Theselectionis basedon thefollowing
diameters:
Theinstalledsystemshall bethe GFPB
pipeworksystemand shallhave the
followingdiameter pipework.
OuterDiameter   InnerDiameter
 16   11.6
 20   14.4
 25   20.4
 32   26.0
 40   32.6
 50   40.8
 63   51.4
 75   61.4
 90   73.6
 110   90.0
 125   102.2
 160   130.8
 225   184.0
AllPB pipeworksizes statedon thedrawings
referto outsidediameters.
Workmanship, Finish and Appearance
Thefinished tubeshall besmooth,freeof
internaland externalmechanical imperfections
andinternallyshall have asmooth appearance.
Packaging and Transportation
Thepipes shouldbe delivered incoilsor
straightlengths, andthe tubesshall be
bundledbysizeinsuitablebagsor cardboard
boxes, clearly markedwith thepurchaseorder
number,material designation,size, totallength
orpiece count andname ofsupplier.
Pipe Joints
Thepipes andfittings shouldbeentirely
compatible witheach otherand thejointing
shouldbe carriedout instrict accordancewith
themanufacturer’s printedinstructions.
Unlessindicated otherwise,the pipejoints in
PBpipework shouldbe madeby socketfusion,
buttfusion, electrofusionor compression.
Theassemblyof theseshould becarriedout
instrict accordancewith themanufacturer’s
instructions.Only fully trained installers should
be used for assembling PB pipe systems.
Trained and Certified by George Fischer or by
George Fischer appointed trainers.
(i)Socket fusion
Utilisingthe correct toolsfor assembly,
heatingand jointingtimes inaccordance
withthe manufacturer’sinstructions.This
shallonlybe carriedout ata workbench,
withthe heatingelementsecurely fixedto
thework bench.
(ii)Electrofusion
Utilisingcorrecttools forassembly,heating
andjointing timesin accordancewith the
manufacturer’sinstructions.
(iii)Butt fusion
Utilisingthe correct toolsfor assembly,
heatingand jointingtimes inaccordance
withthe manufacturer’sinstructions.This
shallonlybe carriedout ata workbench,
withthe heatingelementsecurely fixedto
thework bench.
(iiii)Brass Compression
Fittingsto includeinternal pipesleeveas
integralpart offitting withgrip ringto hold
pipein place.Assembly inaccordancewith
manufacturer’sinstructions.Thismethod
shallonlybe usedto connectto itemsof
plantor tometallic pipeworksections.
Wheredirected,toenable disconnections
tobe undertaken,socket unionsshould be
fittedon pipesup toand including63mm
outsidediameter. Above63mmoutside
diameter,flanged jointsshould beused.
Note:Locations forde-mountableunions
andflanges shallbe asshownon the
drawings. Screwedadaptor fittingsshould
beused atscrewedjointstoappliances
upto 2”normal bore. PBflange adapters
havingdimensions inaccordancewith BS
4504,should beprovidedforconnections
topumps, tanksor equipmentabove2”
nominalbore.
7
Pipework System
Thepiping contractorshould provide samples
ofthe followingfor approval:
- PB piping
- PB pipeworkregulationandisolationvalves
- PB pipeworkbends, teesand tap
 connectors
- PBcleanerandjointing equipmentor  
 (ifapplicable) compressionfittings foruse
 withPB
Ordersfor thepipeworksystemshould notbe
confirmed,nor shouldthe construction ofthe
installationof thesystemproceeduntil these
sampleshavebeen approvedinwriting.
Theapprovedsamplesshould beretained
on-sitefor comparisonwiththeworkas
actually installed.
Theconnections totapson sinksworktopsetc
shouldbe installed withthe manufacturer’s
suitablebrass outlets connectors.
Arrangementsshould bemade toensure
thatthe fittingsand thePBpipetowhichit
isjoined areguardedand secured insuch a
wayas tobe protectedfromundueimpactor
excessivetorque.
PBpipework canbe connected toany heat
source(forexampledomestic hotwater storage
calorifierordirectgas fire waterheater).
Cleaning
Ingeneral thepipe shouldbe flushedwith
mainscold waterafterfinishing theinstallation.
Disinfection
Disinfectionshall becarried outin accordance
withSection 218and themanufacturer’s
guidelines.
Fire Sleeves
Firesleevesshould beused wheresinglePB
pipesof 20mmoutside diameterand aboveor
multiplebanksofpipespenetratefirebarriers.
Theyshould generallycomplywith the
requirements ofthe localfireauthority.
(i)They shouldbe constructedwith an
intumescentlining.
(ii)Casings shouldaccommodatethe expansion
ofintumescent liningsduring fire
conditions.
(iii)Intumescent liningsshould expand
inwardsat atemperatureof about140°C
andcompletelyseal theopenings against
thepassage offlames, fumesand smoke.
Suchlinings shouldalso beinaccordwith
thepipe manufacturer’srequirements.
Note:The pressureof theexpanding
intumescentlining maycrush PBpipes.
(iv)Individual sleevesmountedonvertical
pipeworkshould:
-be ofconstructionsuitablefor surface
mounting
-be installed onthe pipeimmediatelybelow
thebarrier (thecollar shouldbe securely
fixedtothe sleeves,the sleeveand the
flangedcollar buttedupagainstthe fire
barrierand theflange boltedinto position)
orsimilar.
Installing the pipework system
Thecontractorshould:
(i)Check thatthe exteriorof thepiping is
markedat intervalsnotexceeding onemetre
withthe manufacturer’sname, typeof
material,pipe sizeand standard withwhich
itcomplies.
(ii)Check thatall thepipingandfittings
suppliedareuniform incolourdensity.
(iii)Exerciseparticular care intheir
storage,handlingand installationto avoid
deteriorationdue toultravioletlight and
impactdamage.
Thepiping manufacturer’sprinted
instructionsshould berigidlyadhered
toin allrespectsof storage,stacking,
handlingand installation.The pipework
shouldbe supportedas indicatedupon the
drawingsand asdetailedwithin thecontract
documents. Itisessentialthat cleaners
arecorrectlyapplied tothe pipeends and
socketsprior tofusion andelectrofusion
jointingwith cleaningpadschanged
regularly inaccordancewith manufacturer’s
instructions.After fusionjointing, aring of
Polybutylenewill bevisibleon theoutside of
thepipe asevidencethat ajoint hasbeen
completed. Afterelectrofusion anindicator
pipwill raiseabovethe surfaceofthefitting
asevidencethat ajoint hasbeen
completed.
8
Greatcareshould betakento ensure thatonly
themanufacturer’s installationproceduresare
followedand, inparticular, thatthe fullcooling
periodis maintainedbeforeany jointis
considered tobe complete.
Nopipework, orsection thereof, shallhave
waterpressure applieduntil themanufacturer’s
stipulatedsetting periodhas elapsed(a
minimumof atleastone hourafter thelast
fusionpoint).
Wherean existingheatsourcehas tobe
maintained,with pipeseither runningparallel
orcrossingeach other,thermal insulation
shouldbe applied.On noaccountshould
laddersscaffold orother buildingitems
beproppedup againstthePBpipework
installation.
Changesin directioncan beachievedusing the
pipesflexibility,in accordancewith the
manufacturer’sinstructions.Nothermally
inducedbending ofPB pipesthroughthe
applicationof localheating shouldbe
permitted.
AllPB pipesshould besupportedbypipe clips
orsupport brackets,the spacingof which
shouldnot exceedthe maximumintervalsas
advisedand confirmedby thepipe
manufacturer.
Wherea pipeclip orsupport bracketisbeing
usedto supporta numberof pipesof different
materialsand sizes,the spacinginterval
betweensuch clipsand bracketsshouldnot
exceedthe smallestofthe ‘maximumintervals’
statedor advisedfor eachof thepipes being
supported.
PBpipework inexposedpositions (orwhere
distortionis likelytooccur)should be
supportedusing thepiping manufacturer’s
standard pipeclip orsupport pipecarriers.
WherePB pipingis supportedusing otherthat
standard PBpipe clips,the supportsshould
comprisesteelsplit piperings withrubber
insert,nippling rodnuts andwashers with
backplateas required,either fixedto rail
supportor buildingfabric.
Thetest pressureshouldbemaintained
throughoutthe periodof timeof notlessthan
onehour andnot lessthan oneand ahalf
timesworking pressure.
Thereshould beno lossof pressure
abovethatdetailed inthe manufacturer’s
handbook,to allowfor theexpansion and
thesetting inperiod ofPBpipes,during
theperiod thetest isbeing carriedout.
Theresultsof thepressuretest shouldbe
recordedon alogsheet.
Expansion
Expansionloopsorchangesinpipe direction
shouldbe allowedfor atregularintervalsin
accordancewith manufacturer’s guidelines.
Whereexpansion loopsand changes
indirectionareimpracticalfixedpoint
assembly maybe usedon pipesup to75mm
diameterto preventthe PBpipes from
expandingor contracting,in accordancewith
manufacturer’sguidelines.
Warning: Notall PBpiping systemsare
suitablefor fixedpointassembly toresist
theeffects ofexpansion. Pleaseconsultthe
manufacturerbeforeconsideringthe useof
thismethod.
Iffixedpointbracketsarebeingusedto
avoidlongitudinalexpansion ofPB pipes,the
installationinstructionsof boththe pipeand
bracketmanufacturer’sshould beadhered
to.
Fixedpointbracketsshould belocated
atfittings andmust gripthe pipeon
bothsides ofthe fittings,oraccordingto
manufacturer’sinstructions.
Fixedpointsupportsshouldbelocated at
fusionor electrofusionfittings andmeet with
themanufacturer’s requirements, toabsorb
forcesandtransferthem tothe structure.
Fixedpointsshouldnotbelocated more
thana maximumof 6mapart.
Pipesupport carriersmustbe usedto
supportthe pipesbetween fixedpoints,
topreventbuckling. Normalsupports for
thepipes andcarrier, betweenfixedpoints
shouldnot bemorethan 1.5mapart, in
accordancewith themanufacturer’s guide
lines.
9
Pipesupport carriersshall beof semi-circular
shapeto closelymatch thepipes outside
diameter. Manufacturedfromgalvanisedor size
platedsteel. Thecoatinginside andoutside
areto beof thesame standard. Thefinish isto
besmooth alongthesurfaces andedges to
preventdamage tothe pipes.When cutthe
edgesof thecarrier are tobe filedsmooth.
Thecarrier isto beattached tothe pipeby
approvedcableties suitable tosupport the
forces,atintervalsrecommended bythe
manufacturer(nevermorethan 500mm).
Thecarrier isnot tobe runoverfittings,
butto terminate10-15mm shortboth sides
withadequate supportthroughcableties
andbrackets.
Only installers carrying a GF training
certificate shall be used for assembling GF
Polybutylene pipe systems.
Water Treatment
Oncompletionofinstallation, thewholeof the
heatingand primaryhot watersystem isto be
filledandaftera satisfactorypressure andheat
testis achievedemptied andflushed cleanof
allforeignmatter.
Whena cleanwaterconditionis proven,the
systemis tobe dosedwith anapprovedand
recognisedchemicalscaleand corrosion
inhibitingagent.
Thedosing operationis tobe carriedout byan
approvedspecialist andon completion,
certificatesare tobe submittedindicatingthe
chemicalused (andits characteristics)the
percentagedosage introducedandall
otherrelevantdetails requiredtomaintain
satistactoryprotection.
Immediately uponcompletion ofthe dosing
process,noticesareto bepostedin plant
roomsindicating thatthe systemhas been
treated,the chemicalused, thepercentage
concentration, etcand particularly relevant
informationrequired bythe Healthand Safety
atWorkregulations.
Priorto thedosing processcommencing,
theContractor isto submitdetails ofthe
companyit isproposingto engageto perform
theoperation, completewith allrelevant
informationregarding thetype ofchemicals to
beused andthe method.
Dosingby themechanical contractoror any
otherorganisationnot aspecialistwillnot
bepermitted.
GeorgeFischer’s INSTAFLEX TechnicalGuide
isavailableon requestTel:024 76535535 or
on-lineat www.georgefischer.co.uk
10
Pipeexternaldiameter mm16 20 25 32 40 50 63 75 90 110
Torque Nm 3 3 4 5 10 12 15 18 20 22
Connection:
plastic/plastic
Flange connections/unions
O-ringsealingunionsorflange
connectionsshouldbeusedin
principlefordetachableconnection
ofplasticpipesoradaptorsbetween
plasticpipesandmetalpipesormetal
fittings(valves,pumps).
•Unionsuptod63
•Flangeconnectionsuptod110
Highscrewtighteningforcesarenot
requiredformakingflange
connectionswithO-rings.Itis
recommendedtousetorque
wrenchestopreventexcessive
tighteningofscrews.
Nominalvaluesforthescrewfixingof
flangeconnectionswithO-Ring:
Connection:
plastic/metal
•Flange seals arenormallyusedin
flangeconnectionsforthe
 transitionfromplastictometal,
sincethejointingfacesofthemetal
flangeareusuallyserrated.
•Thescrewsshouldalsobe
tightenedwithatorquewrench
Pipe external diameter mm 16 20 25 32 40 50 63 75 90 110
Nominal internal diameter DN mm 10 15 20 25 32 40 50 65 80 100
Torque Nm 6 7 9 10 20 25 30 35 40 45
Commerciallyavailable
screws,nuts,washers.
Washers should be used in
general
forflangeconnectionswithflange
seals,inordertopreventdamage
toflangesorflangeadaptors.The
tablebelowshowsnominalvalues
oftorquesrequiredforthevarious
pipediameters.
11
GF FIRESTOP
Firesleeves
Product Specification
GFFIRESTOPisaonepiece,one
lengthstainlesssteelsleevecomplete
withclosuretabsandslots,having
anintumescentliningrunningthe
fulllengthoftheunitwith3bandsof
AcousticFoamadheredtothebore.
Theunitsarewrappedaroundthe
plasticpipesbyhandandslidintothe
walls/partitions.
Intheeventofacloseproximity
Firestopfiresleeveliningof
intumescentactivatesat140°Cand
expandstoover16timesitsown
volumetocreateafireproofseal
betweenthepipeandthewallwhich
preventsthespreadofthefirebetween
buildingcompartments.
Thefoam,whilstcreatingasmoke
andacousticsealagainstthepipe,
allowsforpipeexpansionandbuilding
movementandisalsoananti-vibratory
material.
FIRESTOPScanbefittedtoeither
horizontalorverticalpipeworkand
althoughtheycanbefreelymovedinto
position,theywillremaininplaceeven
onverticalpipework.
•FIRESTOPSdonotgiveofftoxicfumes
orsmokeintheeventofafire
•FIRESTOPSareasbestosfreeanddo
notcontainanyhazardousmaterials
andtherearenospecialprecautions
requiredforhandlingorinstallingthe
units.
12
INSTAFLEX® Installation
Quick Reference Guide
For full details refer to full INSTAFLEX Training Manual
Socket Fusion Jointing
1. Chamfer pipe ends
2. Clean pipe & fittings
3. Check heater bushes temperature
4. Check and clean heater bushes
5. Set timer to correct heating time
6. Mark fusion depth with gauge
7. Make joint but Do Not Twist after insertion only
adjust for squareness
8. Hold pipe & fitting together for required holding time
9. Carefully put pipe and fitting down for cooling time
For 16 to 110mm Pipe & Fittings
Polybutylene (PB) Socket Fusion Jointing
Pipe outside Wall thickness Welding Heating Holding Cooling
diameter minimum length time time time
o.d. (mm) mm L (mm) t (sec) t1 (sec) t2 (min)
GF FIRESTOP
Firesleeves
13
INSTAFLEX® Installation
Quick Reference Guide
For full details refer to full INSTAFLEX Training Manual
Electrofusion Jointing
1. Cut pipe ends square using correct tool
2. Clean pipe & fittings with PB cleaning fluid
3. Mark insertion depth on pipe
4. Remove electrofusion fitting from bag and insert pipe
5. Tighten fitting ensuring screw head is level with the plastic
6. Check electrofusion leads for damage, if ok connect lead ends onto
the terminal on fitting
7. When joint cycle is complete remove electrofusion leads
from fitting
8. Check for fusion indicators pips rising close to the terminal
For 16 to 110mm Pipe & Fittings
Polybutylene (PB) Electrofusion Jointing
Pipe outside Wall thickness Welding Heating Cooling
diameter minimum length time time
o.d. (mm) mm L (mm) t (sec) t2 (sec)
27
30
34
37
40
44
50
67
73.5
80
45
50
65
75
85
105
120
105
110
120
4
4
4
4
4
4
6
6
6
6
14
Working with plastic pipes
W R O N G R I G H T
and fittings
Transportandstorageofplasticpipes
Plasticsarematerialssensitiveto
impactandcrushingatlow
temperatures.
Thetemperaturelimitdependson
therelevantmaterial.
PP-R
PVC-C +5°C
PB –10°C
VPE –20°C
Belowthesetemperaturespipes
andfittingswouldhavetobe
protectedparticularlyfrom
impacts,crushingandother
externalmechanical
stresses.
Plastic pipes and plastic fittings must be protected in principle from
external influences. Direct sunlight, impacts and compressive
stresses should be avoided. The pipes and fittings must be left in
their packing until used. They should not be stored out of doors.
Safety instruction
!
15
Pipes in coils
PB pipe in protective pipe in coils
packed in cardboard boxes
3700
d
[mm]
s
[mm]
Code SP GP kg/m D
[mm]
16 2.2 760 853 387 60 0 0.162 25
20 2.8 760 853 388 60 0 0.235 30
25 2.3 760 854 910 30 0 0.270 34
 
PB pipe in coils
packed in cardboard boxes
*packed in protective wrap
* on request
3710
d
[mm]
s
[mm]
Code SP GP kg/m
 
16 2.2 760 853 389 60 0 0.100
20 2.8 760 853 390 60 0 0.150
25 2.3 760 854 946 30 0 0.165
 
 
Protective pipe PE in coils
packed in cardboard boxes
* on request
3720
d
[mm]
Colors Code SP GP kg/m D
[mm]
16 black 760 853 393 60 0 0.062 25
*16 blue 760 856 616 60 0 0.062 25
*16 red 760 856 617 60 0 0.062 25
20 black 760 853 394 60 0 0.085 30
*20 blue 760 856 618 60 0 0.085 30
*20 red 760 856 619 60 0 0.085 30
16
PB pipe in straight lengths
PB pipe in straight lengths of 5.8m
packed in cardboard boxes
3714
d
[mm]
s
[mm]
Code GP kg/m SP
[m]
 
16 2.2 760 856 606 0 0.097 52.2
20 2.8 760 856 607 0 0.151 52.2
25 2.3 760 856 608 0 0.165 58.0
32 2.9 760 856 609 0 0.270 23.2
40 3.7 760 856 610 0 0.416 17.4
50 4.6 760 856 611 0 0.645 17.4
63 5.8 760 856 612 0 1.020 5.8
75 6.8 760 856 613 0 1.440 5.8
90 8.2 760 856 614 0 2.060 5.8
110 10.0 760 856 615 0 3.050 5.8
 
PB Pipe in straight lengths 5.8m
packed in PE-Bag
5200
d
[mm]
s
[mm]
Code SP GP kg/m Length
[m]
 
125 11.4 761 065 290 6 0 3.950 5.80
160 14.6 761 065 291 6 6 6.460 5.80
225 20.5 761 065 292 6 6 12.700 5.80
 
 
17
Accessories
Cap for protective pipe3921
d
[mm]
Colors Code SP GP kg L
[mm]
D
[mm]
16 red 760 854 986 10 0 0.005 70 25
16 green 760 854 987 10 0 0.005 70 25
20 red 760 854 988 10 0 0.007 70 30
20 green 760 854 989 10 0 0.007 70 30
 
Pipe support tray3929
d
[mm]
Code SP GP kg/m L
[mm]
 
40 760 854 928 30 0 0.360 3000
50 760 854 929 30 0 0.450 3000
63 760 854 930 30 0 0.570 3000
75 760 854 985 30 0 0.680 3000
 
 
Pipe binder3930
d-d
[mm]
Code SP GP kg L
[mm]
 
16 - 40 760 853 283 100 0 0.001 200
50 - 75 760 853 284 100 0 0.003 300
90 - 110 760 854 984 100 0 0.001 430
 
 
Clip pipe support tray3931
d
[mm]
Code SP GP kg/m L
[mm]
 
16 760 856 602 30 0 0.270 3000
20 760 856 603 30 0 0.320 3000
25 760 856 604 30 0 0.480 3000
32 760 856 605 30 0 0.600 3000
 
 
Pipe clamp5091
d
[mm]
Code SP GP kg M
[mm]
16 761 066 296 50 0 0.040 8
20 761 066 297 50 0 0.050 8
25 761 066 298 50 0 0.051 8
32 761 066 299 50 0 0.060 8
40 761 066 300 50 0 0.081 8
50 761 066 301 50 0 0.091 8
63 761 066 302 50 0 0.132 8
75 761 066 303 50 0 0.152 8
90 761 066 304 25 0 0.191 10
110 761 066 305 25 0 0.232 10
 
18
Armaflex Insulation
13mm Insulation Tube
60 30 50
d
[mm]
Code SP kg Length
[mm]
 
16 760 305 010 20 0.095 2000
20 760 305 011 20 0.123 2000
25 760 305 012 20 0.154 2000
32 760 305 013 20 0.220 2000
40 760 305 014 20 0.230 2000
50 760 305 015 20 0.275 2000
63 760 305 016 20 0.417 2000
75 760 305 017 20 0.455 2000
90 760 305 018 20 0.500 2000
110 760 305 019 20 0.667 2000
 
 
Firestops
Fire Protection Sleeves
Outer stainless steel sleeve, inner intumescent lining and three acoustic foam seals.
Fire protection up to 120 minutes.
Tested to BS476:Part 20
On contact with fire, the FIRESTOP's intumescent lining expands to over 16 times its
original volume, thereby crushing the plastic pipe and forming a smoke and flame barri-
er.
d
[mm]
Code SP kg Length
[mm]
 
16 PIL008199 12 0.059 205
20 PIL008200 12 0.065 205
25 PIL008201 12 0.124 205
32 PIL008202 12 0.141 205
40 PIL008203 12 0.167 205
50 PIL008204 12 0.194 205
63 PIL008205 12 0.237 205
75 PIL008206 8 0.272 205
90 PIL008207 8 0.315 205
110 PIL008208 8 0.368 205
160 PIL008209 0.450 205
225 PIL008210 0.800 205
 
19
Fittings for socket fusion jointing
Elbow 90°5005
d
[mm]
Code SP kg L
[mm]
D
[mm]
z
[mm]
    
16 761 066 600 10 0.014 25 22 10
20 761 066 601 10 0.015 28 26 13
25 761 066 602 10 0.026 32 32 14
32 761 066 603 10 0.035 38 40 18
40 761 066 604 5 0.076 44 51 22
50 761 066 605 5 0.116 51 64 26
63 761 066 606 2 0.239 62 81 34
75 761 066 607 2 0.310 75 91 44
90 761 066 608 2 0.500 88 108 52
110 761 066 609 2 0.900 105 132 63
    
    
Elbow 90°, socket-spigot5008
d
[mm]
Code SP kg L
[mm]
D
[mm]
h
[mm]
z
[mm]
     
16 761 066 900 10 0.009 25 22 34 10
20 761 066 901 10 0.012 28 26 36 13
25 761 066 902 10 0.021 32 32 44 14
32 761 066 903 10 0.037 38 40 50 18
40 761 066 904 5 0.067 44 51 58 22
50 761 066 905 5 0.122 51 64 70 26
63 761 066 906 2 0.233 62 81 82 34
     
     
Elbow 45°5010
d
[mm]
Code SP kg L
[mm]
D
[mm]
z
[mm]
16 761 066 610 10 0.008 21 22 6
20 761 066 611 10 0.016 22 26 7
25 761 066 612 10 0.026 25 32 7
32 761 066 613 10 0.030 30 40 10
40 761 066 614 5 0.064 34 51 12
50 761 066 615 5 0.090 39 64 14
63 761 066 616 2 0.145 45 81 17
75 761 066 617 2 0.210 51 92 20
90 761 066 618 2 0.430 58 109 22
110 761 066 619 2 0.640 68 134 26
 
20
Elbow 45°, socket-spigot5018
d
[mm]
Code SP kg L
[mm]
D
[mm]
h
[mm]
z
[mm]
     
16 761 066 907 10 0.008 21 22 29 6
20 761 066 908 10 0.011 22 26 30 7
25 761 066 909 10 0.017 25 32 35 7
32 761 066 910 10 0.032 30 40 40 10
40 761 066 911 5 0.055 34 51 46 12
50 761 066 912 5 0.099 39 64 53 14
63 761 066 913 2 0.180 45 81 62 17
     
     
Tee 90° equal5015
d
[mm]
Code SP kg L
[mm]
D
[mm]
z
[mm]
    
16 761 066 620 10 0.017 25 22 10
20 761 066 621 10 0.025 28 26 13
25 761 066 622 10 0.036 32 32 14
32 761 066 623 10 0.045 38 40 18
40 761 066 624 5 0.105 44 51 22
50 761 066 625 5 0.145 51 64 26
63 761 066 626 2 0.315 62 81 34
75 761 066 627 2 0.430 75 91 44
90 761 066 628 2 0.750 88 112 52
110 761 066 629 2 1.120 105 132 63
    
    
Tee 90° reduced5020
d1
[mm]
d2
[mm]
d3
[mm]
Code SP kg D
[mm]
D2
[mm]
L1
[mm]
L2
[mm]
L3
[mm]
z1
[mm]
z2
[mm]
z3
[mm]
           
20 16 20 761 066 914 10 0.015 26 22 28 28 28 13 13 13
20 16 16 761 066 915 10 0.016 26 22 28 28 28 13 13 13
20 20 16 761 066 916 10 0.017 26 26 28 28 28 13 13 13
25 16 25 761 066 917 10 0.025 32 26 32 32 32 14 17 14
25 20 25 761 066 918 10 0.023 32 26 32 32 32 14 17 14
25 20 20 761 066 919 10 0.026 32 26 32 32 32 14 17 17
25 25 20 761 066 920 10 0.027 32 32 32 32 32 14 14 17
32 16 32 761 066 921 10 0.041 40 26 38 38 38 18 23 18
32 20 32 761 066 922 10 0.039 40 26 38 38 38 18 23 18
32 25 32 761 066 923 10 0.040 40 32 38 38 38 18 20 18
40 16 40 761 066 295 5 0.083 51 34 44 44 44 22 29 22
40 25 40 761 066 924 5 0.077 51 34 44 44 44 22 26 22
50 16 50 761 066 309 5 0.135 64 34 51 51 51 26 36 26
50 25 50 761 066 925 5 0.130 64 34 51 51 51 26 33 26
63 16 63 761 066 310 2 0.257 81 35 62 62 62 34 47 34
63 25 63 761 066 926 5 0.252 81 35 62 62 62 34 44 34
           
           
21
Socket5040
d
[mm]
Code SP kg L
[mm]
D
[mm]
z
[mm]
16 761 066 660 10 0.009 33 22 3
20 761 066 661 10 0.014 33 26 3
25 761 066 662 10 0.020 39 32 3
32 761 066 663 10 0.033 43 40 3
40 761 066 664 10 0.048 48 51 4
50 761 066 665 10 0.069 54 64 4
63 761 066 666 2 0.120 60 81 4
75 761 066 667 2 0.150 69 91 7
90 761 066 668 2 0.250 80 110 8
110 761 066 669 2 0.440 94 133 10
 
Reducing bush5045
d
[mm]
d1
[mm]
Code SP kg L
[mm]
z
[mm]
   
16 20 761 066 670 10 0.005 30 15
16 25 761 066 671 10 0.010 33 18
20 25 761 066 672 10 0.015 33 18
20 32 761 066 674 10 0.018 40 25
25 32 761 066 675 10 0.022 40 22
20 40 761 066 677 10 0.024 42 27
25 40 761 066 678 10 0.028 42 24
32 40 761 066 679 10 0.034 42 22
20 50 761 066 681 10 0.035 55 40
25 50 761 066 682 10 0.038 55 37
32 50 761 066 683 10 0.042 55 35
40 50 761 066 684 10 0.050 55 33
20 63 761 066 686 5 0.055 58 43
25 63 761 066 687 5 0.060 58 40
32 63 761 066 688 5 0.066 58 38
40 63 761 066 689 5 0.074 58 36
50 63 761 066 690 5 0.079 58 33
63 75 761 066 742 2 0.115 67 39
63 90 761 066 746 2 0.149 74 46
75 90 761 066 745 2 0.160 74 43
63 110 761 066 747 2 0.229 86 58
75 110 761 066 749 2 0.234 86 55
90 110 761 066 748 2 0.270 86 50
   
Cap5050
d
[mm]
Code SP kg L
[mm]
16 761 066 650 10 0.006 22
20 761 066 651 10 0.010 24
25 761 066 652 10 0.014 28
32 761 066 653 10 0.022 32
40 761 066 654 10 0.024 38
50 761 066 655 10 0.050 44
63 761 066 656 5 0.079 50
 
22
Plug5051
d
[mm]
Code SP kg h
[mm]
25 761 066 938 10 0.008 33
 
Adaptor INSTAFLEX-Hepworth5053
d1
[mm]
d2
[mm]
Code SP kg d
[mm]
L
[mm]
    
16 20 761 066 326 10 0.005 15 54
    
Weld-in-Saddle
* on request
5054
d - d1
[mm]
Code SP kg h1
[mm]
z
[mm]
 
*40 - 20 761 068 000 5 0.011 15 11
50 - 20 761 068 003 5 0.011 15 11
50 - 25 761 068 004 5 0.014 18 11
50 - 32 761 068 005 5 0.020 20 11
63 - 20 761 068 006 5 0.012 15 11
63 - 25 761 068 007 5 0.016 18 11
63 - 32 761 068 008 5 0.022 20 11
75 - 20 761 068 009 5 0.014 15 12
75 - 25 761 068 010 5 0.017 18 12
75 - 32 761 068 011 5 0.022 20 12
90 - 20 761 068 012 5 0.018 15 13
90 - 25 761 068 013 5 0.021 18 13
90 - 32 761 068 014 5 0.027 20 13
110 - 20 761 068 015 5 0.019 15 14
110 - 25 761 068 016 5 0.022 18 14
110 - 32 761 068 017 5 0.020 20 14
 
Weld-in-Saddle5054
d - d1
[mm]
Code SP kg h1
[mm]
z
[mm]
 
125 - 32 761 068 018 5 0.035 20 16
125 - 40 761 068 019 5 0.056 22 16
125 - 50 761 068 020 5 0.072 25 16
160 - 32 761 068 021 5 0.045 20 16
160 - 40 761 068 022 5 0.061 22 16
160 - 50 761 068 023 5 0.077 25 16
225 - 32 761 068 024 5 0.076 20 16
225 - 40 761 068 025 5 0.076 22 16
225 - 50 761 068 026 5 0.092 25 16
 
 
23
Weld-in-Saddle with male thread
* on request
5058
d - d1
[mm]
R
[inch]
Code SP kg l
[mm]
z
[mm]
 
*50 - 25 3
4761 068 041 2 0.147 91 66
*63 - 32 1 761 068 042 2 0.220 95 70
*75 - 32 1 761 068 043 2 0.220 96 71
*90 - 32 1 761 068 044 2 0.224 97 72
*110 - 32 1 761 068 045 2 0.244 98 73
 
 
Weld-in-Saddle with male thread
* on request
5058
d - d1
[mm]
R
[inch]
Code SP kg l
[mm]
z
[mm]
 
*125 - 32 1 761 068 046 2 0.232 100 90
*160 - 32 1 761 068 047 2 0.232 100 90
*225 - 32 1 761 068 048 2 0.261 100 90
 
 
Special reducer with hole
Drilled hole d16 to d50
* on request
6227
d1
[mm]
d2
[mm]
Code SP kg l
[mm]
 
*75 16 761 069 500 1 0.200 88
*75 20 761 069 501 1 0.200 88
*75 25 761 069 502 1 0.200 88
*75 32 761 069 503 1 0.200 88
*75 40 761 069 504 1 0.200 88
*75 50 761 069 505 1 0.200 88
*90 16 761 069 506 1 0.250 87
*90 20 761 069 507 1 0.250 87
*90 25 761 069 508 1 0.250 87
*90 32 761 069 509 1 0.250 87
*90 40 761 069 510 1 0.250 87
*90 50 761 069 511 1 0.250 87
*110 16 761 069 512 1 0.400 94
*110 20 761 069 513 1 0.400 94
*110 25 761 069 514 1 0.400 94
*110 32 761 069 515 1 0.400 94
*110 40 761 069 516 1 0.400 94
*110 50 761 069 517 1 0.400 94
 
24
Special reducer with transition on
male thread
* on request
6229
d-d
[mm]
R
[inch]
Code SP kg l
[mm]
l1
[mm]
z
[mm]
 
*75 - 20 1
2761 069 583 1 0.280 146 88 131
*75 - 25 3
4761 069 584 1 0.325 150 88 130
*75 - 32 1 761 069 593 1 0.385 152 88 127
*90 - 20 1
2761 069 585 1 0.340 145 87 130
*90 - 25 1
2761 069 586 1 0.385 149 87 129
*90 - 32 1 761 069 594 1 0.445 151 87 126
*110 - 20 1
2761 069 587 1 0.480 150 94 135
*110 - 25 3
4761 069 588 1 0.525 151 94 131
*110 - 32 1 761 069 595 1 0.585 155 94 130
 
 
Special reducer with transition on
female thread
* on request
6219
d-d
[mm]
Rp
[inch]
Code SP kg l
[mm]
l1
[mm]
z
[mm]
 
*75 - 20 1
2761 069 577 1 0.284 144 88 129
*75 - 25 3
4761 069 578 1 0.336 145 88 125
*75 - 32 1 761 069 596 1 0.385 149 88 124
*90 - 20 1
2761 069 579 1 0.344 143 87 128
*90 - 25 3
4761 069 580 1 0.396 144 87 124
*90 - 32 1 761 069 597 1 0.445 148 87 123
*110 - 20 1
2761 069 581 1 0.484 152 94 137
*110 - 25 3
4761 069 582 1 0.536 156 94 136
*110 - 32 1 761 069 598 1 0.585 158 94 133
 
 
25
Union
Union, socket-socket
including O-Ring, EPDM quality for potable water
5035
d
[mm]
Code SP kg L
[mm]
z1
[mm]
z2
[mm]
G
[inch]
     
16 761 066 691 10 0.135 43 8 5 1
20 761 066 692 10 0.150 43 8 5 11/4
25 761 066 693 10 0.200 49 8 5 11/2
32 761 066 694 5 0.295 53 8 5 2
40 761 066 695 5 0.450 59 10 5 21/2
50 761 066 696 2 0.560 65 10 5 23/4
63 761 066 697 2 0.900 71 10 5 31/2
     
     
Adaptor union, socket-male thread
including O-Ring, EPDM quality for potable water
5036
d
[mm]
R
[inch]
Code SP kg L
[mm]
h
[mm]
z
[mm]
G
[inch]
     
16 1
2761 066 698 10 0.262 61 38 8 1
20 1
2761 066 699 10 0.150 63 40 8 11/4
25 3
4761 066 700 10 0.320 67 41 8 11/2
32 1 761 066 701 5 0.340 73 45 8 2
40 1 1
4761 066 702 5 0.560 80 48 10 21/2
50 1 1
2761 066 703 2 0.800 83 48 10 23/4
63 2 761 066 704 2 0.900 92 54 10 31/2
     
     
Adaptor union, socket-female thread
including O-Ring, EPDM quality for potable water
5037
d
[mm]
Rp
[inch]
Code SP kg L
[mm]
z1
[mm]
z2
[mm]
G
[inch]
     
16 1
2761 066 705 10 0.207 45 8 9 1
20 1
2761 066 706 10 0.120 47 8 10 11/4
25 3
4761 066 707 10 0.280 50 8 9 11/2
32 1 761 066 708 5 0.270 53 8 8 2
40 1 1
4761 066 709 5 0.600 58 10 7 21/2
50 1 1
2761 066 710 2 0.700 61 10 7 23/4
63 2 761 066 711 2 0.720 66 10 5 31/2
     
     
26
Flange jointing
Flange adaptor flat
suitable for flange or union nut
5030
d
[mm]
Code SP kg L
[mm]
h
[mm]
D
[mm]
D1
[mm]
z
[mm]
    
20 761 066 631 10 0.007 20 6 27 34 5
25 761 066 632 10 0.010 23 7 33 41 5
32 761 066 633 10 0.016 25 7 41 50 5
40 761 066 634 10 0.025 27 8 50 61 5
50 761 066 635 10 0.034 30 8 61 73 5
63 761 066 636 2 0.060 33 9 76 90 5
75 761 066 637 2 0.090 35 10 90 106 4
90 761 066 638 2 0.130 42 11 109 125 6
110 761 066 639 2 0.230 49 12 131 150 7
    
    
Flange adaptor with groove
suitable for flange or union nut
including O-Ring, EPDM quality for potable water
5031
d
[mm]
Code SP kg L
[mm]
D
[mm]
D1
[mm]
z
[mm]
    
16 761 066 640 10 0.006 23 22 29 8
20 761 066 641 10 0.008 23 27 34 8
25 761 066 642 10 0.012 26 33 41 8
32 761 066 643 10 0.018 28 41 50 8
40 761 066 644 10 0.030 32 50 61 10
50 761 066 645 10 0.040 35 61 73 10
63 761 066 646 2 0.071 38 76 90 10
75 761 066 647 2 0.090 40 90 106 9
90 761 066 648 2 0.130 47 109 125 11
110 761 066 649 2 0.230 55 131 150 13
    
27
Seals
O-Ring Gasket
Model:
For Flange Adaptors
Hardness approx. 65° Shore
EPDM 48 41 00
FPM 49 41 00
d
[mm]
DN
[mm]
EPDM
Code
 
16 10 748 410 000
20 15 748 410 001
25 20 748 410 007
32 25 748 410 002
40 32 748 410 003
50 40 748 410 012
63 50 748 410 013
75 65 748 410 014
90 80 748 410 015
110 100 748 410 016
125 100 748 410 017
140 125 748 410 018
160 150 748 410 019
200 200 748 410 163
225 200 748 410 022
250 250 748 410 182
280 250 748 410 173
315 300 748 410 174
 
d
[mm]
DN
[mm]
FPM
Code
SP GP kg kg/m SID pcs.-Pal. Vol.-Pal.
  
16 10 749 410 000 0 0 0.002 0.002 1 0 0
20 15 749 410 001 100 0 0.002 0.002 1 0 0
25 20 749 410 007 100 1400 0.002 0.002 1 10080 960
32 25 749 410 002 100 0 0.003 0.003 1 0 0
40 32 749 410 003 0 0 0.007 0.007 1 0 0
50 40 749 410 012 100 1000 0.008 0.008 1 36000 960
63 50 749 410 013 100 600 0.011 0.011 1 21600 960
75 65 749 410 014 100 600 0.012 0.012 1 21600 960
90 80 749 410 015 100 600 0.015 0.015 1 21600 960
110 100 749 410 016 50 200 0.031 0.031 1 7200 960
125 100 749 410 017 200 0 0.036 0.036 1 7200 960
140 125 749 410 018 200 0 0.039 0.039 1 7200 960
160 150 749 410 019 200 0 0.044 0.044 1 7200 960
200 200 749 410 163 0 0 0.056 0.056 1 0 0
225 200 749 410 022 150 0 0.060 0.060 1 2700 960
250 250 749 410 182 0 0 0.003 0.003 3 0 0
280 250 749 410 173 0 0 0.044 0.044 1 0 0
315 300 749 410 174 0 0 0.051 0.051 3 0 0
  
d
[mm]
D
[mm]
D1
[mm]
D2
[mm]
closest
inch
  
16 26 19 3.53 3
8
20 31 23 3.53 1
2
25 35 28 3.53 3
4
32 43 36 3.53 1
40 55 44 5.34 1 1
4
50 64 53 5.34 1 1
2
63 80 69 5.34 2
75 93 82 5.34 2 1
2
90 112 101 5.34 3
110 134 120 6.99 4
125 150 136 6.99
140 166 152 6.99 5
160 191 177 6.99 6
200 236 222 6.99 8
225 255 241 6.99 8
250 280 266 6.99 9
280 306 292 6.99 10
315 356 342 6.99 12
  
28
Profile Flange Gasket
metric
for flange adaptors without chamfer
Model:
for flange adaptor No. 27 79 85 PP-H SDR11 without chamfer
Profile Gasket with steel insert (type G-ST-P/K)
Hardness: 70° Shore EPDM, 75° Shore FPM
d
[mm]
EPDM
Code
FPM
Code
SP GP kg kg/m SID pcs.-Pal. Vol.-Pal.
  
20 748 440 706 749 440 706 0 0 0.008 0.008 1 0 0
25 748 440 707 749 440 707 0 0 0.011 0.011 1 0 0
32 748 440 708 749 440 708 0 0 0.014 0.014 1 0 0
40 748 440 709 749 440 709 0 0 0.021 0.021 1 0 0
50 748 440 710 749 440 710 0 0 0.022 0.022 1 0 0
63 748 440 711 749 440 711 0 0 0.041 0.041 1 0 0
75 748 440 712 749 440 712 0 0 0.055 0.055 1 0 0
90 748 440 713 749 440 713 0 0 0.062 0.062 1 0 0
110 748 440 309 749 440 309 0 0 0.112 0.112 1 0 0
125 748 440 310 749 440 310 0 0 0.110 0.110 1 0 0
140 748 440 311 749 440 311 0 0 0.146 0.146 1 0 0
160 748 440 312 749 440 312 0 0 0.207 0.207 1 0 0
180 748 440 313 749 440 313 0 0 0.260 0.260 1 0 0
200 748 440 314 749 440 314 0 0 0.430 0.430 1 0 0
225 748 440 315 749 440 315 0 0 0.365 0.365 1 0 0
250 748 440 316 749 440 316 0 0 0.520 0.520 1 0 0
280 748 440 317 749 440 317 0 0 0.496 0.496 1 0 0
315 748 440 318 749 440 318 0 0 0.600 0.600 1 0 0
355 748 440 319 749 440 319 0 0 0.750 0.750 3 0 0
400 748 440 320 749 440 320 0 0 0.750 0.750 3 0 0
  
d
[mm]
D
[mm]
D1
[mm]
H
[mm]
H1
[mm]
  
20 51 20 4 3
25 61 22 4 3
32 71 28 4 3
40 82 40 4 3
50 92 46 4 3
63 107 58 5 4
75 127 69 5 4
90 142 84 5 4
110 162 93 6 5
125 162 105 6 5
140 192 117 6 5
160 218 135 8 6
180 218 151 8 6
200 273 168 8 6
225 273 188 8 6
250 328 208 8 6
280 328 233 8 6
315 378 262 8 6
355 438 294 8 6
400 489 331 8 6
  
29
Backing Flanges, Steel
Backing Flange, Galvanised Steel
for Socket Systems
Model:
Galvanised steel, suitable for laying underground
Connecting dimension: ISO 7005, EN 1092, BS 4504, DIN 2501
Bolt circle PN10/16
AL: number of holes
*Bolt circle PN16
24 70 16
d
[mm]
DN
[mm]
d
[inch]
PN Code kg D
[mm]
D1
[mm]
D2
[mm]
D3
[mm]
H
[mm]
AL SC
     
20 15 1
216 724 701 606 0.220 95 65 28 14 7 4 M12x55
25 20 3
416 724 701 607 0.320 105 75 34 14 7 4 M12x60
32 25 1 16 724 701 608 0.410 115 85 42 14 7 4 M12x60
40 32 1 1
416 724 701 609 0.820 140 100 51 18 8 4 M16x70
50 40 1 1
216 724 701 610 1.040 150 110 62 18 8 4 M16x75
63 50 2 16 724 701 611 1.220 165 125 78 18 8 4 M16x80
75 65 2 1
216 724 701 612 1.440 185 145 92 18 8 4 M16x85
90 80 3 16 724 701 613 1.530 200 160 110 18 8 4 M16x90
110 100 16 724 700 014 1.840 220 180 133 18 8 8 M16x95
100 4 16 724 701 615 1.620 220 180 138 18 8 8 M16x95
140 125 5 16 724 701 616 2.250 250 210 167 18 8 8 M16x110
150 6 16 724 701 617 2.510 285 240 200 22 8 8 M20x120
*225 200 8 6 724 701 720 3.000 340 295 250 22 8 12 M20x150
     
Union nut
suitable for flange adaptor and union
5081
d
[mm]
G
[inch]
Code SP GP kg kg/m SID pcs.-Pal. Vol.-Pal.
  
16 1 761 066 188 0 130 0.092 0.092 3 4680 960
20 1 1
4761 066 100 0 140 0.090 0.090 3 5040 960
25 1 1
2761 066 101 0 80 0.110 0.110 3 2880 960
32 2 761 066 102 0 0 0.144 0.144 1 0 0
40 2 1
2761 066 103 0 0 0.230 0.230 3 0 0
50 2 3
8761 066 104 0 0 0.261 0.261 1 0 0
63 2 3
4761 066 105 0 0 0.328 0.328 1 0 0
  
  
30
Fittings for Compression Joints
Transition with female thread3301
d
[mm]
Rp
[inch]
Code SP kg z
[mm]
 
16 1
2760 853 104 5 0.078 12
16 3
4760 853 105 5 0.105 15
20 1
2760 853 194 5 0.077 14
20 3
4760 853 153 5 0.118 15
 
 
Transition with female thread
* on request
3301
d
[mm]
Rp
[inch]
Code SP kg z
[mm]
Remarks
 
25 3
4760 856 231 10 0.165 7
25 1 760 856 232 10 0.209 13
32 1 760 856 233 10 0.317 7
40 1 1
4760 856 234 10 0.453 7
50 1 1
2760 856 235 5 0.625 7
63 2 760 856 236 1 1.570 9
75 2 1
2760 856 248 1 1.976 10 without approval
*90 3 760 856 261 1 0.800 9 without approval
*110 4 760 856 262 1 5.800 38 without approval
 
Transition with male thread3310
d
[mm]
R
[inch]
Code SP kg h
[mm]
 
16 1
2760 853 107 5 0.105 30
16 3
4760 853 108 5 0.086 34
20 1
2760 853 195 5 0.090 38
20 3
4760 853 138 5 0.098 36
 
 
Transition with male thread
* on request
3310
d
[mm]
R
[inch]
Code SP kg h
[mm]
Remarks
 
25 3
4760 856 241 10 0.149 35
25 1 760 856 242 10 0.175 41
32 1 760 856 243 10 0.256 42
40 1 1
4760 856 244 10 0.343 44
50 1 1
2760 856 245 5 0.490 47
63 2 760 856 246 1 0.812 32
75 2 1
2760 856 247 1 1.127 37 without approval
*90 3 760 856 263 1 0.800 32 without approval
*110 4 760 856 264 1 1.000 38 without approval
 
Socket3330
d
[mm]
Code SP kg z
[mm]
 
16 760 853 124 2 0.073 26
20 760 853 151 2 0.294 28
 
 
31
Elbow 90°3363
d
[mm]
Code SP kg z
[mm]
z1
[mm]
 
16 760 854 842 5 0.199 22 22
20 760 854 843 5 0.262 24 24
 
 
Transition elbow 90° with male thread3364
d
[mm]
R
[inch]
Code SP kg h
[mm]
z
[mm]
 
16 1
2760 854 838 5 0.171 35 27
16 3
4760 854 839 2 0.184 35 27
20 1
2760 869 991 5 0.190 35 29
20 3
4760 854 840 5 0.208 35 29
25 3
4760 854 819 2 0.500 40 29
 
 
Tee 90°, equal3350
d
[mm]
Code SP kg z
[mm]
 
16 760 853 125 2 0.259 22
20 760 853 131 2 0.388 24
 
 
Tee 90°, reduced3355/3356/3357
d3
[mm]
d1
[mm]
d2
[mm]
Code SP kg z1
[mm]
z2
[mm]
z3
[mm]
      
20 20 16 760 853 136 2 0.360 24 23 23
16 20 16 760 853 140 2 0.330 24 23 23
16 20 20 760 853 137 2 0.319 24 24 23
      
      
32
Transition Tee with female thread3359
d
[mm]
Rp
[inch]
Code SP kg z1
[mm]
z2
[mm]
z3
[mm]
    
20 1
2760 854 841 5 0.320 24 22 24
    
    
Transition Tee with male thread3358
d
[mm]
R
[inch]
Code SP kg z
[mm]
h
[mm]
   
16 1
2760 854 711 2 0.225 19 38
20 1
2760 856 211 2 0.327 24 39
   
   
Transition Tee with male thread3360
d
[mm]
R
[inch]
Code SP kg z
[mm]
h
[mm]
   
16 1
2760 869 987 2 0.200 22 30
   
   
33
Manifolds in nonferrous metal
Manifold 90°, 3/4" (DN 20)
Metal with compression connections
3270
d
[mm]
Rp
[inch]
R
[inch]
Code SP kg h
[mm]
h1
[mm]
L
[mm]
L1
[mm]
z
[mm]
z1
[mm]
z2
[mm]
       
16 3
4 3
41-fold 760 853 189 5 0.207 59 31 28 0 45 24 14
20 3
4 3
41-fold 760 853 190 5 0.264 69 36 33 0 55 26 19
16 3
4 3
42-fold 760 853 180 5 0.383 104 31 28 45 90 24 14
16 3
4 3
43-fold 760 853 181 5 0.560 149 31 28 45 135 24 14
16 3
4 3
44-fold 760 853 182 5 0.470 194 31 28 45 180 24 14
       
       
Manifold 90°, 1" (DN 25)
Metal with compression connections
3250
d
[mm]
Rp
[inch]
R
[inch]
Code SP kg h
[mm]
h1
[mm]
L
[mm]
L1
[mm]
z
[mm]
z1
[mm]
z2
[mm]
       
16 1 1 1-fold 760 854 860 5 0.210 62 34 28 0 45 29 11
20 1 1 1-fold 760 854 855 5 0.260 75 42 33 0 58 29 16
16 1 1 2-fold 760 854 861 1 0.460 107 34 28 45 90 29 11
20 1 1 2-fold 760 854 892 5 0.640 135 42 33 60 118 29 16
16 1 1 3-fold 760 854 862 1 0.670 152 34 28 45 135 29 11
16 1 1 4 fold 760 854 863 1 0.860 197 34 28 45 180 29 11
       
       
34
Accessories
Union nut3800
d
[mm]
Code SP kg
 
16 760 853 018 5 0.032
20 760 853 071 2 0.043
 
 
Clamping ring3801
d
[mm]
Code SP kg
 
16 760 853 019 5 0.014
20 760 853 072 2 0.020
 
 
Cap
including seal
3211
d
[mm]
Code SP kg
 
16 760 853 110 5 0.051
20 760 853 150 5 0.094
 
 
Cap3266
Rp
[inch]
Code SP kg
 
3
4760 853 794 5 0.084
1760 853 706 5 0.134
 
 
35
Plug3267
R
[inch]
Code SP kg
 
3
4760 853 792 5 0.050
1760 853 793 5 0.084
 
 
36
Fittings for Compression Joints
Equal Tee
Body only - adaptor fitting required per inlet/ outlet
e.g. use 15mm or 16mm adaptor fittings to reduce on a branch
d
[mm]
Code kg
15 / 16 / 20 760 305 102 0.118
Elbow 90°
Body only - adaptor fitting required per inlet/ outlet
e.g. use 15mm or 16mm adaptor fittings to reduce
d
[mm]
Code kg
15 / 16 / 20 760 305 104 0.118
Radiator Duckfoot Bend
Body only - adaptor fitting required per inlet/ outlet
e.g. for use with 15mm Cu or 16/20mm PB
d
[mm]
Code kg
15 / 16 / 20 760 305 127 0.118
 
Back Plate Elbow
Body only - adaptor fitting required for PB/Cu connection
e.g. right angle connection of either 15mm Cu or 16/20mm PB to 1/2 BSP
d-d
[inch]
Code kg
RBM x 1/2 760 305 148 0.118
Manifold Plus range
37
Adaptors for Compression Joints
Manifold Adaptor
Body only - adaptor fitting required for PB/Cu connection
d
[mm]
d
[inch]
Code kg
 
15 / 16 / 20 3
4760 305 151 0.272
22 / / 3
4760 305 153 0.150
25 / / 3
4760 305 152 0.150
 
 
Instaflex Female Adaptor BSP
Body only - adaptor fittings required for Instaflex side
e.g. use 16mm adaptor fittings to reduce on a branch
d
[mm]
d
[inch]
Code kg
 
15 / 16 / 20 1
2760 305 138 0.118
25 / / 3
4760 305 146 0.150
 
 
Instaflex Male Adaptor BSP
Body only - adaptor fittings required for Instaflex side
e.g. use 16mm adaptor fittings to reduce on a branch
d
[mm]
d
[inch]
Code kg
 
15 / 16 / 20 1
2760 305 140 0.118
 
 
Instaflex to Copper Connectors
Body only - adaptor fittings required for PB/Cu connection
e.g. use to connect PB pipe to Cu pipe
* Available until stocks last
d
[mm]
d
[mm]
Code kg
 
16 / 20 15 762 856 387 0.118
16 / 20 22 760 305 150 0.118
* 25 22 760 305 147 0.118
 
Tap Connector
Body only - adaptor fittings required for Instaflex side
e.g. use to connect 16mm or 20mm PB pipe tp BSP male thread tap connection
d
[mm]
d
[inch]
Code kg
 
15 / 16 / 20 1
2760 305 132 0.272
15 / 16 / 20 3
4760 305 133 0.272
 
38
Adaptor Fittings
for Copper Pipe
Size Code kg
15 x Cu 760 305 126 0.118
22 x Cu 760 305 149 0.118
 
Adaptor Fittings
for Copper, Chromed Brass, etc (universal)
Size Code kg
15 x Cu 760 305 144 0.118
 
Adaptor Fittings
for Flexalino thin wall PB pipe
* Available until stocks last
d x e
[mm]
Code kg
16 x 1.5 761 856 384 0.058
*20 x 1.9 761 305 126 0.118
Adaptor Fittings
for Instaflex PB pipe
* Available until stocks last
d x e
[mm]
Code kg
16 x 2.2 760 856 382 0.079
20 x 2.8 760 856 383 0.056
*25 x 2.3 760 856 390 0.058
39
Manifolds & Valves for Compression Joints
Manifolds
For connection from manifold ports to services in either 15mm, 16mm or 20mm.
10 bar pressure rating
d
[inch]
d
[mm]
Type Code kg
 
3
415 / 16 / 20 2-port 760 856 380 0.480
3
415 / 16 / 20 3-port 767 856 393 0.704
 
Ball Valves
(1/4 turn)
Body only - adaptor fittings required for Instaflex side.
d
[mm]
Code kg
15 / 16 / 20 761 856 385 0.272
25 / / 769 856 398 0.408
40
Accessories for Compression Joints
Brackets for Manifolds
Set of two
d
[inch]
Code kg
 
3
4760 305 130 0.301
 
Plugs and Caps for Manifolds
d
[inch]
Type Code kg
 
3
4Plug 760 305 124 0.118
3
4Cap 760 305 125 0.118
 
Caps for Manifold Outlets
Type Code kg
RBM Thread PIL008301 0.118
 
Spanners for RBM fittings
e.g. to allow tightening of fittings onto manifold
Size Code kg
 
RBM 760 305 143 0.300
 
41
Fittings for electrofusion jointing
Electrofusion coupler
middle stop can be broken out
6200
d
[mm]
Code SP kg L
[mm]
 
16 761 069 200 1 0.023 76
20 761 069 201 1 0.027 80
25 761 069 202 1 0.041 85
32 761 069 203 1 0.053 85
40 761 069 204 1 0.084 95
50 761 069 205 1 0.121 99
63 761 069 206 1 0.184 102
75 761 069 265 1 0.310 134
90 761 069 266 1 0.474 147
110 761 069 267 1 0.716 160
 
Electrofusion coupler
PN 16
6240
d
[mm]
Code SP kg L
[mm]
 
125 761 069 555 1 1.500 186
160 761 069 556 1 1.700 190
225 761 069 557 1 1.700 220
 
 
Bracket clamp
on request
6235
d
[mm]
Code SP kg
 
16 761 069 490 10 0.016
20 761 069 491 10 0.019
25 761 069 492 10 0.025
32 761 069 493 6 0.032
40 761 069 494 6 0.050
50 761 069 495 6 0.073
63 761 069 496 6 0.102
75 761 069 497 6 0.166
90 761 069 498 4 0.252
110 761 069 499 4 0.380
 
 
42
Electrofusion adaptor
Spigot for socket fusion
6201
d
[mm]
Code SP kg L
[mm]
h
[mm]
   
16 761 069 207 1 0.014 60 23
20 761 069 208 1 0.017 61 22
25 761 069 209 1 0.026 67 25
32 761 069 210 1 0.037 71 29
40 761 069 211 1 0.060 79 32
50 761 069 212 1 0.095 85 36
63 761 069 213 1 0.151 94 43
   
   
Electrofusion elbow 90°6202
d
[mm]
Code SP kg L
[mm]
z
[mm]
   
16 761 069 214 1 0.023 47 10
20 761 069 215 1 0.027 54 14
25 761 069 216 1 0.039 58 16
32 761 069 217 1 0.079 60 18
40 761 069 218 1 0.128 69 22
50 761 069 219 1 0.206 78 29
63 761 069 220 1 0.328 86 36
75 761 069 221 1 0.325 112 45
90 761 069 222 1 0.593 127 54
110 761 069 223 1 0.980 146 66
   
   
Electrofusion elbow 45°6203
d
[mm]
Code SP kg L
[mm]
z
[mm]
   
16 761 069 227 1 0.023 44 6
20 761 069 228 1 0.027 46 7
25 761 069 229 1 0.039 50 8
32 761 069 230 1 0.059 51 9
40 761 069 231 1 0.070 58 11
50 761 069 232 1 0.147 63 14
63 761 069 233 1 0.328 68 17
75 761 069 234 1 0.325 88 21
90 761 069 235 1 0.593 98 25
110 761 069 236 1 0.880 111 31
   
   
43
Elbow 90° socket-spigot6222
d
[mm]
Code SP kg L
[mm]
h
[mm]
l
[mm]
z
[mm]
     
16 761 069 434 1 0.025 47 53 40 10
20 761 069 435 1 0.035 54 58 40 14
25 761 069 436 1 0.047 58 62 42 16
32 761 069 437 1 0.064 60 66 42 18
40 761 069 438 1 0.113 69 77 47 22
50 761 069 439 1 0.181 78 85 49 29
63 761 069 440 1 0.290 86 96 51 36
     
     
Elbow 45° socket-spigot6223
d
[mm]
Code SP kg L
[mm]
h
[mm]
l
[mm]
z
[mm]
     
16 761 069 447 1 0.014 44 50 38 6
20 761 069 448 1 0.030 46 54 40 7
25 761 069 449 1 0.042 50 57 42 8
32 761 069 450 1 0.059 51 60 42 9
40 761 069 451 1 0.098 58 67 47 11
50 761 069 452 1 0.156 63 75 49 14
63 761 069 453 1 0.242 68 79 51 17
     
     
Electrofusion Tee 90° equal6204
d
[mm]
Code SP kg L
[mm]
z
[mm]
   
16 761 069 237 1 0.053 47 10
20 761 069 238 1 0.067 54 14
25 761 069 239 1 0.089 58 16
32 761 069 240 1 0.116 60 18
40 761 069 241 1 0.185 69 22
50 761 069 242 1 0.290 78 29
63 761 069 243 1 0.452 86 36
75 761 069 244 1 0.487 112 45
90 761 069 245 1 0.890 127 54
110 761 069 246 1 1.320 146 66
   
   
44
Electrofusion Tee 90° reducer6205
d1
[mm]
d2
[mm]
d3
[mm]
Code SP kg L1
[mm]
L2
[mm]
L3
[mm]
z1
[mm]
z2
[mm]
z3
[mm]
         
20 16 16 761 069 249 1 0.058 54 47 47 14 10 10
20 16 20 761 069 250 1 0.041 54 49 54 14 11 14
25 16 25 761 069 251 1 0.079 58 54 58 16 16 16
25 20 20 761 069 256 1 0.079 58 54 54 16 14 14
25 20 25 761 069 252 1 0.078 58 54 58 16 14 16
25 25 20 761 069 257 1 0.081 58 58 54 16 16 14
32 20 32 761 069 253 1 0.088 60 58 60 18 18 18
32 25 25 761 069 258 1 0.098 60 58 58 18 16 16
32 25 32 761 069 254 1 0.095 60 58 60 18 16 18
40 20 40 761 069 259 1 0.157 69 63 69 22 23 22
40 25 40 761 069 255 1 0.115 69 63 69 22 21 22
40 32 40 761 069 260 1 0.168 69 63 69 22 21 22
50 25 50 761 069 261 1 0.246 78 72 78 29 30 29
50 32 50 761 069 262 1 0.360 78 72 78 29 30 29
63 25 63 761 069 263 1 0.360 86 81 86 36 39 36
63 40 63 761 069 264 1 0.384 86 85 86 36 38 36
         
         
Electrofusion adaptor Tee 90° with male thread6224
d
[mm]
R
[inch]
Code SP kg L
[mm]
h
[mm]
z
[mm]
    
25 3
4761 069 430 1 0.176 58 78 15
32 1 761 069 431 1 0.225 60 86 17
    
    
45
Electrofusion reducer6207
d1
[mm]
d2
[mm]
Code SP kg h
[mm]
l
[mm]
z
[mm]
   
20 16 761 069 277 1 0.023 83 40 45
25 16 761 069 278 1 0.026 83 42 46
25 20 761 069 279 1 0.026 86 42 47
32 16 761 069 457 1 0.033 86 42 48
32 20 761 069 280 1 0.030 84 42 45
32 25 761 069 281 1 0.038 89 42 47
40 20 761 069 458 1 0.055 102 47 62
40 25 761 069 459 1 0.060 104 47 62
40 32 761 069 282 1 0.060 95 47 53
50 20 761 069 460 1 0.070 102 49 62
50 25 761 069 461 1 0.075 104 49 62
50 32 761 069 462 1 0.075 95 49 53
50 40 761 069 283 1 0.091 103 49 56
63 20 761 069 463 1 0.096 102 51 62
63 25 761 069 464 1 0.103 104 51 62
63 32 761 069 284 1 0.101 95 51 53
63 40 761 069 465 1 0.121 103 51 56
63 50 761 069 285 1 0.141 106 51 57
75 63 761 069 286 1 0.232 129 67 78
90 63 761 069 287 1 0.289 128 74 77
90 75 761 069 288 1 0.362 143 74 76
110 63 761 069 289 1 0.414 135 80 84
110 75 761 069 290 1 0.460 150 80 83
110 90 761 069 291 1 0.491 165 80 92
   
Electrofusion cap6206
d
[mm]
Code SP kg L
[mm]
 
16 761 069 270 1 0.022 67
20 761 069 271 1 0.025 70
25 761 069 272 1 0.036 77
32 761 069 273 1 0.054 83
40 761 069 274 1 0.095 95
50 761 069 275 1 0.153 104
63 761 069 276 1 0.265 116
 
 
ELS Manifold PB5062
d
[mm]
d1
[mm]
Code SP kg L
[mm]
L1
[mm]
h
[mm]
h1
[mm]
H
[mm]
z
[mm]
z1
[mm]
z2
[mm]
          
25 16 single 761 066 250 1 0.031 31 0 63 32 60 45 36 13
25 20 single 761 066 251 1 0.041 39 0 78 39 64 60 35 21
25 16 double 761 066 252 1 0.062 31 45 108 32 60 90 36 13
25 16 triple 761 066 253 1 0.092 31 45 153 32 60 135 36 13
25 16 4 fold 761 066 254 1 0.121 31 45 198 32 60 180 36 13
          
46
Electrofusion special reducer with adaptor
* on request
6239
d1
[mm]
d2
[mm]
Code SP kg l
[mm]
l1
[mm]
z
[mm]
   
*75 16 761 069 604 1 0.201 134 88 97
*75 20 761 069 605 1 0.204 134 88 95
*75 25 761 069 606 1 0.213 137 88 95
*75 32 761 069 607 1 0.224 139 88 97
*75 40 761 069 608 1 0.247 145 88 98
*75 50 761 069 609 1 0.282 148 88 99
*90 16 761 069 610 1 0.254 133 87 96
*90 20 761 069 611 1 0.257 133 87 94
*90 25 761 069 612 1 0.266 136 87 94
*90 32 761 069 613 1 0.277 138 87 96
*90 40 761 069 614 1 0.300 144 87 97
*90 50 761 069 615 1 0.335 147 87 98
*110 16 761 069 518 1 0.405 140 94 103
*110 20 761 069 519 1 0.405 140 94 101
*110 25 761 069 520 1 0.415 143 94 101
*110 32 761 069 521 1 0.425 145 94 103
*110 40 761 069 522 1 0.450 151 94 104
*110 50 761 069 523 1 0.480 154 94 105
   
   
Electrofusion special reducer with transition
on elbow
* on request
6238
d1
[mm]
d2
[mm]
Code SP kg l
[mm]
l1
[mm]
y
[mm]
z
[mm]
    
*75 16 761 069 616 1 0.213 107 88 47 10
*75 20 761 069 619 1 0.223 109 88 54 14
*75 25 761 069 524 1 0.235 111 88 58 16
*75 32 761 069 525 1 0.300 115 88 60 18
*75 40 761 069 526 1 0.300 121 88 96 22
*75 50 761 069 527 1 0.365 127 88 78 29
*90 16 761 069 617 1 0.260 106 87 47 10
*90 20 761 069 620 1 0.270 108 87 54 14
*90 25 761 069 528 1 0.283 110 87 58 16
*90 32 761 069 529 1 0.300 114 87 60 18
*90 40 761 069 530 1 0.350 120 87 69 22
*90 50 761 069 531 1 0.415 126 87 78 29
*110 16 761 069 618 1 0.413 113 94 47 10
*110 20 761 069 621 1 0.423 115 94 54 14
*110 25 761 069 532 1 0.435 117 94 58 16
*110 32 761 069 533 1 0.453 121 94 60 18
*110 40 761 069 534 1 0.500 127 94 69 22
*110 50 761 069 535 1 0.565 183 94 78 29
    
    
47
Special reducer with transition on
female thread
* on request
6219
d-d
[mm]
Rp
[inch]
Code SP kg l
[mm]
l1
[mm]
z
[mm]
 
*75 - 20 1
2761 069 577 1 0.284 144 88 129
*75 - 25 3
4761 069 578 1 0.336 145 88 125
*75 - 32 1 761 069 596 1 0.385 149 88 124
*90 - 20 1
2761 069 579 1 0.344 143 87 128
*90 - 25 3
4761 069 580 1 0.396 144 87 124
*90 - 32 1 761 069 597 1 0.445 148 87 123
*110 - 20 1
2761 069 581 1 0.484 152 94 137
*110 - 25 3
4761 069 582 1 0.536 156 94 136
*110 - 32 1 761 069 598 1 0.585 158 94 133
 
 
Special reducer with transition on
male thread
* on request
6229
d-d
[mm]
R
[inch]
Code SP kg l
[mm]
l1
[mm]
z
[mm]
 
*75 - 20 1
2761 069 583 1 0.280 146 88 131
*75 - 25 3
4761 069 584 1 0.325 150 88 130
*75 - 32 1 761 069 593 1 0.385 152 88 127
*90 - 20 1
2761 069 585 1 0.340 145 87 130
*90 - 25 1
2761 069 586 1 0.385 149 87 129
*90 - 32 1 761 069 594 1 0.445 151 87 126
*110 - 20 1
2761 069 587 1 0.480 150 94 135
*110 - 25 3
4761 069 588 1 0.525 151 94 131
*110 - 32 1 761 069 595 1 0.585 155 94 130
 
 
48
Special reducer with hole
Drilled hole d16 to d50
* on request
6227
d1
[mm]
d2
[mm]
Code SP kg l
[mm]
 
*75 16 761 069 500 1 0.200 88
*75 20 761 069 501 1 0.200 88
*75 25 761 069 502 1 0.200 88
*75 32 761 069 503 1 0.200 88
*75 40 761 069 504 1 0.200 88
*75 50 761 069 505 1 0.200 88
*90 16 761 069 506 1 0.250 87
*90 20 761 069 507 1 0.250 87
*90 25 761 069 508 1 0.250 87
*90 32 761 069 509 1 0.250 87
*90 40 761 069 510 1 0.250 87
*90 50 761 069 511 1 0.250 87
*110 16 761 069 512 1 0.400 94
*110 20 761 069 513 1 0.400 94
*110 25 761 069 514 1 0.400 94
*110 32 761 069 515 1 0.400 94
*110 40 761 069 516 1 0.400 94
*110 50 761 069 517 1 0.400 94
 
49
Adaptors with threads
Adaptor with male thread
Spigot for electrofusion and socket fusion - male thread
SF = socket fusion
ELF = electrofusion
6214
d
[mm]
R
[inch]
Code SP kg h
[mm]
L min. SF
[mm]
L min. ELF
[mm]
 
16 1
2761 069 385 1 0.082 91 30 47
20 1
2761 069 386 1 0.093 93 30 49
20 3
4761 069 387 1 0.115 96 30 49
25 3
4761 069 388 1 0.134 103 33 55
25 1 761 069 389 1 0.171 105 33 55
32 1 761 069 390 1 0.207 105 35 55
40 1 1
4761 069 391 1 0.615 145 27 50
50 1 1
2761 069 392 1 0.930 158 30 52
63 2 761 069 393 1 1.387 173 33 54
 
Adaptor with female thread
Spigot for electrofusion and socket fusion- female thread
SF = socket fusion
ELF = electrofusion
6215
d
[mm]
Rp
[inch]
Code SP kg z
[mm]
L min. SF
[mm]
L min. ELF
[mm]
 
16 1
2761 069 360 1 0.086 75 30 47
20 1
2761 069 361 1 0.099 77 30 49
20 3
4761 069 362 1 0.136 78 30 49
25 3
4761 069 363 1 0.145 83 33 55
25 1 761 069 364 1 0.184 85 33 55
32 1 761 069 365 1 0.209 85 35 55
40 1 1
4761 069 366 1 0.615 118 27 50
50 1 1
2761 069 367 1 0.930 124 30 52
63 2 761 069 368 1 1.387 133 33 55
 
Adaptor with loose union nut, flat seal
Spigot for electrofusion and socket fusion- female thread
including flat seal EPDM
SF = socket fusion
ELF = electrofusion
6216
d
[mm]
G
[inch]
Code SP kg z
[mm]
L min. SF
[mm]
L min. ELF
[mm]
 
16 3
4761 069 370 1 0.093 78 30 47
20 3
4761 069 369 1 0.126 88 30 49
20 1 761 069 371 1 0.154 82 30 49
25 3
4761 069 372 1 0.146 95 33 55
25 1 761 069 373 1 0.230 99 33 55
25 1 1
4761 069 374 1 0.231 89 33 55
32 1 761 069 375 1 0.210 99 35 55
32 1 1
4761 069 377 1 0.292 100 35 55
32 1 1
2761 069 376 1 0.292 89 35 55
40 1 1
4761 069 378 1 0.510 138 27 50
40 1 1
2761 069 379 1 0.598 138 27 50
40 2 761 069 381 1 0.824 140 27 50
50 1 3
4761 069 384 1 0.898 147 30 53
50 2 1
4761 069 383 1 0.820 126 30 53
63 2 3
8761 069 394 1 1.421 158 33 53
63 2 3
4761 069 395 1 0.854 135 33 54
 
50
Adaptor with loose union nut, flat seal, with centering
Spigot for electrofusion and socket fusion- female thread
including gasket, tesnit blue free of asbestos, according to DIN 3754
SF = socket fusion
ELF = electrofusion
6217
d
[mm]
G
[inch]
Code SP kg z
[mm]
L min. SF
[mm]
L min. ELF
[mm]
   
16 1
2761 069 380 1 0.086 83 30 47
20 3
4761 069 382 1 0.128 85 30 49
   
   
51
Unions
Adaptor union
Spigot for electrofusion and socket fusion - male thread
including O-Ring, EPDM quality for potable water
6220
d
[mm]
G
[inch]
Code SP kg H
[mm]
h
[mm]
h1
[mm]
l
[mm]
G
[inch]
D
[mm]
     
16 1
2761 069 400 1 0.260 106 68 38 45 1 41
20 1
2761 069 401 1 0.280 110 70 40 47 11/4 46
25 3
4761 069 402 1 0.325 117 76 41 50 11/2 52
32 1 761 069 403 1 0.465 123 78 45 50 2 64
40 1 1
4761 069 404 1 0.700 136 88 48 56 21/2 79
50 1 1
2761 069 405 1 0.830 141 93 48 58 23/4 85
63 2 761 069 406 1 1.205 152 98 54 60 31/2 104
     
     
Adaptor union
Spigot for electrofusion and socket fusion- female thread
including O-Ring, EPDM quality for potable water
6221
d
[mm]
Rp
[inch]
Code SP kg L
[mm]
h
[mm]
l
[mm]
z
[mm]
G
[inch]
D
[mm]
     
16 1
2761 069 407 1 0.210 90 68 45 9 1 41
20 1
2761 069 408 1 0.235 94 70 47 10 11/4 46
25 3
4761 069 409 1 0.295 100 76 50 9 11/2 52
32 1 761 069 410 1 0.405 103 78 50 8 2 64
40 1 1
4761 069 411 1 0.600 114 88 56 7 21/2 79
50 1 1
2761 069 412 1 0.730 119 93 58 7 23/4 85
63 2 761 069 413 1 1.055 126 98 60 5 31/2 104
     
Electrofusion Adaptor union
including O-Ring, EPDM quality for potable water
6225
d
[mm]
R
[inch]
Code SP kg L
[mm]
h
[mm]
z
[mm]
G
[inch]
D
[mm]
    
16 1
2761 069 475 1 0.270 106 38 31 1 41
20 1
2761 069 476 1 0.284 109 40 30 11/4 50
25 3
4761 069 477 1 0.332 116 41 33 11/2 56
32 1 761 069 478 1 0.476 124 45 37 2 69
40 1 1
4761 069 479 1 0.711 137 48 42 21/2 83
50 1 1
2761 069 480 1 0.840 143 48 46 23/4 90
63 2 761 069 481 1 1.232 158 54 53 31/2 110
    
    
Electrofusion Adaptor union
including O-Ring, EPDM quality for potable water
6226
d
[mm]
Rp
[inch]
Code SP kg L
[mm]
z1
[mm]
z2
[mm]
G
[inch]
D
[mm]
    
16 1
2761 069 482 1 0.220 90 31 9 1 41
20 1
2761 069 483 1 0.244 93 30 10 11/4 50
25 3
4761 069 484 1 0.302 99 33 9 11/2 56
32 1 761 069 485 1 0.416 104 37 8 2 69
40 1 1
4761 069 486 1 0.611 115 42 7 21/2 83
50 1 1
2761 069 487 1 0.740 121 46 7 23/4 90
63 2 761 069 488 1 1.082 132 53 5 31/2 110
    
    
52
Flange connections
Flange adaptor flat with groove and spigots for
electrofusion
suitable for flange or union nut
including O-Ring, EPDM quality for potable water
* on request
6209
d
[mm]
Code SP kg h
[mm]
l
[mm]
D
[mm]
D1
[mm]
   
*20 761 069 307 5 0.017 70 47 27 34
*25 761 069 308 5 0.023 76 50 33 41
*32 761 069 309 1 0.036 78 50 41 50
*40 761 069 310 1 0.061 88 56 50 61
*50 761 069 311 1 0.099 93 58 61 73
*63 761 069 312 1 0.155 98 60 76 90
*75 761 069 313 1 0.309 158 118 90 106
*90 761 069 314 1 0.496 172 125 109 125
*110 761 069 315 1 0.783 186 131 131 150
   
Flange adaptor flat with spigot for electrofusion
suitable for flange or union nut
* on request
6210
d
[mm]
Code SP kg h
[mm]
l
[mm]
D
[mm]
D1
[mm]
   
*20 761 069 321 1 0.017 67 45 27 34
*25 761 069 322 1 0.023 73 50 33 41
*32 761 069 323 1 0.036 75 50 41 50
*40 761 069 324 1 0.060 83 56 50 61
*50 761 069 325 1 0.092 88 58 61 73
63 761 069 326 1 0.146 93 60 76 90
75 761 069 327 1 0.292 153 118 90 106
90 761 069 328 1 0.471 167 125 109 125
110 761 069 329 1 0.745 180 131 131 150
   
53
Seals
O-Ring Gasket
Model:
For Flange Adaptors
Hardness approx. 65° Shore
EPDM 48 41 00
FPM 49 41 00
d
[mm]
DN
[mm]
EPDM
Code
FPM
Code
SP kg D
[mm]
D1
[mm]
D2
[mm]
closest
inch
      
16 10 748 410 000 749 410 000 0 0.002 26 19 3.53 3
8
20 15 748 410 001 749 410 001 100 0.002 31 23 3.53 1
2
25 20 748 410 007 749 410 007 100 0.002 35 28 3.53 3
4
32 25 748 410 002 749 410 002 100 0.003 43 36 3.53 1
40 32 748 410 003 749 410 003 0 0.007 55 44 5.34 1 1
4
50 40 748 410 012 749 410 012 100 0.008 64 53 5.34 1 1
2
63 50 748 410 013 749 410 013 100 0.011 80 69 5.34 2
75 65 748 410 014 749 410 014 100 0.012 93 82 5.34 2 1
2
90 80 748 410 015 749 410 015 100 0.015 112 101 5.34 3
110 100 748 410 016 749 410 016 50 0.031 134 120 6.99 4
125 100 748 410 017 749 410 017 200 0.036 150 136 6.99
140 125 748 410 018 749 410 018 200 0.039 166 152 6.99 5
160 150 748 410 019 749 410 019 200 0.044 191 177 6.99 6
200 200 748 410 163 749 410 163 0 0.056 236 222 6.99 8
225 200 748 410 022 749 410 022 150 0.060 255 241 6.99 8
250 250 748 410 182 749 410 182 0 0.003 280 266 6.99 9
280 250 748 410 173 749 410 173 0 0.044 306 292 6.99 10
315 300 748 410 174 749 410 174 0 0.051 356 342 6.99 12
      
Profile Flange Gasket
metric
EPDM / FPM
Model:
For all metric GF Flange Adaptors
Profile Gasket with steel insert (type G-ST-P/K)
Hardness: 70° Shore EPDM, 75° Shore FPM
Centering on the inner diameter of the screw crown
material steel insert: carbon steel
di FAare the suitable inner diametersof flange adaptors
EPDM 48 44 07
FPM 49 44 07
d
[mm]
DN
[mm]
PN EPDM
Code
FPM
Code
kg D
[mm]
D1
[mm]
H
[mm]
H1
[mm]
di FA
[mm]
    
16 10 16 748 440 705 749 440 705 0.007 46 16 4 3 6 - 16
20 15 16 748 440 706 749 440 706 0.008 51 20 4 3 10 - 20
25 20 16 748 440 707 749 440 707 0.011 61 22 4 3 12 - 22
32 25 16 748 440 708 749 440 708 0.014 71 28 4 3 18 - 28
40 32 16 748 440 709 749 440 709 0.021 82 40 4 3 30 - 40
50 40 16 748 440 710 749 440 710 0.022 92 46 4 3 36 - 46
63 50 16 748 440 711 749 440 711 0.041 107 58 5 4 48 - 58
75 65 16 748 440 712 749 440 712 0.055 127 69 5 4 59 - 69
90 80 16 748 440 713 749 440 713 0.062 142 84 5 4 73 - 84
110 100 16 748 440 714 749 440 714 0.085 162 104 6 5 94 - 104
125 100 16 748 440 715 749 440 715 0.158 162 123 6 5 113 - 123
140 125 16 748 440 716 749 440 716 0.118 192 137 6 5 127 - 137
160 / 180 150 16 748 440 717 749 440 717 0.153 218 160 8 6 150 - 160
200 200 16 748 440 719 749 440 719 0.263 273 203 8 6 192 - 203
225 200 16 748 440 720 749 440 720 0.181 273 220 8 6 207 - 220
250 250 16 748 440 721 749 440 721 0.410 328 252 8 6 238 - 252
280 250 16 748 440 722 749 440 722 0.226 328 274 8 6 264 - 274
315 300 16 748 440 723 749 440 723 0.334 378 306 8 6 296 - 306
355 350 16 748 440 724 749 440 724 0.410 438 355 10 7 340 - 355
400 400 16 748 440 725 749 440 725 0.513 489 400 10 7 385 - 400
450 500 16 748 440 726 749 440 726 0.718 594 403 10 7 393 - 403
500 500 16 748 440 727 749 440 727 0.718 594 447 10 7 437 - 447
560 600 16 748 440 728 749 440 728 0.923 695 494 10 7 484 - 494
630 600 16 748 440 729 749 440 729 0.923 695 555 10 7 545 - 555
    
54
Backing Flanges, Steel
Backing Flange, Galvanised Steel
for Socket Systems
Model:
Galvanised steel, suitable for laying underground
Connecting dimension: ISO 7005, EN 1092, BS 4504, DIN 2501
Bolt circle PN10/16
AL: number of holes
*Bolt circle PN16
24 70 16
d
[mm]
DN
[mm]
d
[inch]
PN Code kg D
[mm]
D1
[mm]
D2
[mm]
D3
[mm]
H
[mm]
AL SC
     
20 15 1
216 724 701 606 0.220 95 65 28 14 7 4 M12x55
25 20 3
416 724 701 607 0.320 105 75 34 14 7 4 M12x60
32 25 1 16 724 701 608 0.410 115 85 42 14 7 4 M12x60
40 32 1 1
416 724 701 609 0.820 140 100 51 18 8 4 M16x70
50 40 1 1
216 724 701 610 1.040 150 110 62 18 8 4 M16x75
63 50 2 16 724 701 611 1.220 165 125 78 18 8 4 M16x80
75 65 2 1
216 724 701 612 1.440 185 145 92 18 8 4 M16x85
90 80 3 16 724 701 613 1.530 200 160 110 18 8 4 M16x90
110 100 16 724 700 014 1.840 220 180 133 18 8 8 M16x95
100 4 16 724 701 615 1.620 220 180 138 18 8 8 M16x95
140 125 5 16 724 701 616 2.250 250 210 167 18 8 8 M16x110
150 6 16 724 701 617 2.510 285 240 200 22 8 8 M20x120
*225 200 8 6 724 701 720 3.000 340 295 250 22 8 12 M20x150
     
55
Fittings for electrofusion and butt fusion
Elbow 90°
PN 10
5202
d
[mm]
Code SP GP kg kg/m SID pcs.-Pal. Vol.-Pal. z
[mm]
L
[mm]
   
125 761 065 258 1 6 1.600 1.600 1 72 960 182 93
160 761 065 259 1 5 3.150 3.150 1 40 960 213 104
225 761 065 260 1 0 6.500 6.500 1 12 960 270 122
   
   
Elbow 45°
PN 10
5203
d
[mm]
Code SP GP kg kg/m SID pcs.-Pal. Vol.-Pal. z
[mm]
L
[mm]
   
125 761 065 261 1 6 1.600 1.600 1 72 960 140 92
160 761 065 262 1 6 2.500 2.500 1 48 960 162 102
225 761 065 263 1 2 5.500 5.500 1 16 960 200 122
   
   
Tee 90° equal
PN 10
5201
d
[mm]
Code SP GP kg kg/m SID pcs.-Pal. Vol.-Pal. z
[mm]
L
[mm]
   
125 761 065 255 1 4 2.440 2.440 1 48 960 183 93
160 761 065 256 1 4 4.400 4.400 1 32 960 210 102
225 761 065 257 1 0 11.500 11.500 1 12 960 270 122
   
   
Reducer
PN 10
5205
d1
[mm]
d2
[mm]
Code SP GP kg kg/m SID pcs.-Pal. Vol.-Pal.
  
125 110 761 065 267 1 8 0.750 0.750 1 96 960
160 125 761 065 268 1 8 1.300 1.300 1 96 960
225 160 761 065 269 1 4 2.800 2.800 1 48 960
  
56
d1
[mm]
z
[mm]
L1
[mm]
L2
[mm]

125 215 92 85
160 245 102 92
225 280 122 102

Electrofusion coupler
PN 16
6240
d
[mm]
Code SP GP kg kg/m SID pcs.-Pal. Vol.-Pal. L
[mm]
  
125 761 069 555 1 5 1.500 1.500 1 100 960 186
160 761 069 556 1 5 1.700 1.700 1 48 960 190
225 761 069 557 1 2 1.700 1.700 1 24 960 220
  
  
Flange adaptor flat5204
d
[mm]
Code SP GP kg kg/m SID pcs.-Pal. Vol.-Pal.
  
125 761 065 264 1 4 0.900 0.900 1 156 960
160 761 065 265 1 6 1.800 1.800 1 72 960
225 761 065 266 1 2 2.200 2.200 1 42 960
  
d
[mm]
z
[mm]
d1
[mm]
d2
[mm]
L
[mm]
b
[mm]

125 170 132 160 123 25
160 200 176 216 147 25
225 200 235 268 122 32


Backing flanges5085
d
[mm]
Code SP GP kg kg/m SID pcs.-Pal. Vol.-Pal.
  
125 761 065 279 2 0 1.500 1.500 1 0 0
160 761 065 280 2 0 2.500 2.500 1 0 0
225 761 065 281 2 0 3.600 3.600 1 0 0
  
d
[mm]
d
[mm]
D
[mm]
D1
[mm]
D2
[mm]
D3
[mm]
H
[mm]
AL Screws Tightening torque
[N/mm²]
     
125 125 226 180 135 18 23 8 M16 x 130 50
160 160 296 240 178 22 28 8 M20 x 140 60
225 225 350 295 238 22 31 8 M20 x 160 75
     
     
57
Valves in Polybutylene
Valve PB
Range of use
for socket fusion
Gasket: EPDM quality for potable water
Attention:
(do not use as drain valve)
(do not use for compressed air)
Handwheel anthracite with green/red changeover disk
5070
d
[mm]
Code SP GP kg kg/m SID pcs.-Pal. Vol.-Pal. H
[mm]
L
[mm]
z
[mm]
D
[mm]
    
20 761 066 284 1 8 0.270 0.270 1 560 960 86 40 25 70
25 761 066 958 8 10 0.340 0.340 1 560 960 86 40 22 70
32 761 066 959 10 10 0.350 0.350 1 0 0 91 43 23 70
40 761 066 289 4 4 1.000 1.000 1 288 960 155 55 33 90
50 761 066 290 4 4 1.050 1.050 1 288 960 155 60 35 90
63 761 066 291 3 3 1.235 1.235 1 216 960 155 75 47 90
    
    
Valve PB with spigot G 1/4" for drain
Range of use
for socket fusion
Gasket: EPDM quality for potable water
Attention:
(do not use as drain valve)
(do not use for compressed air)
Drain valve must be ordered seperately
Handwheel anthracite with green/red changeover disk
5073
d
[mm]
Code SP GP kg kg/m SID pcs.-Pal. Vol.-Pal. H
[mm]
L
[mm]
z
[mm]
D
[mm]
      
20 761 066 272 1 6 0.395 0.395 1 360 960 86 40 25 70
25 761 066 273 6 6 0.388 0.388 1 360 960 86 40 22 70
32 761 066 274 6 6 0.402 0.402 1 360 960 91 43 23 70
40 761 066 275 4 4 1.020 1.020 1 288 960 155 55 33 90
50 761 066 276 4 4 1.070 1.070 1 288 960 155 60 35 90
63 761 066 277 3 3 1.260 1.260 1 216 960 155 75 47 90
      
58
Valve PB concealed
Range of use
for finished mounting set ( e.g. GROHE / KLUDI / a. o. )
for socket fusion
Gasket: EPDM quality for potable water
Attention:
(do not use as drain valve)
(do not use for compressed air)
5075
d
[mm]
Code SP GP kg kg/m SID pcs.-Pal. Vol.-Pal.
  
20 (15) 761 066 286 1 10 0.350 0.350 1 0 0
25 (20) 761 066 955 8 8 0.340 0.340 1 0 0
32 (25) 761 066 956 8 10 0.360 0.360 1 0 0
  
  
Valve PB with spigot G1/4" for drain
Range of use
for electrofusion
Gasket: EPDM quality for potable water
Attention:
(do not use as drain valve)
(do not use for compressed air)
Drain valve must be ordered seperately
Handwheel anthracite with green/red changeover disk
6208
d
[mm]
Code SP GP kg SID pcs.-Pal. Vol.-Pal. H
[mm]
L
[mm]
z
[mm]
D
[mm]
  
20 (15) 761 069 294 6 6 0.445 1 360 960 86 86 47 70
25 (20) 761 069 295 6 6 0.452 1 0 0 86 89 47 70
32 (25) 761 069 296 6 6 0.494 1 198 960 91 94 52 70
40 (32) 761 069 297 2 2 1.160 1 0 0 155 112 65 90
50 (40) 761 069 298 2 2 1.290 1 0 0 155 120 71 90
63 (50) 761 069 299 1 1 1.624 1 0 0 155 141 90 90
  
59
Valve PB
Range of use
for electrofusion
Gasket: EPDM quality for potable water
Attention:
(do not use as drain valve)
(do not use for compressed air)
Handwheel anthracite with green/red changeover disk
6211
d
[mm]
Code SP GP kg SID pcs.-Pal. Vol.-Pal. H
[mm]
L
[mm]
z
[mm]
D
[mm]
  
20 (15) 761 069 330 6 6 0.396 1 0 0 86 86 47 70
25 (20) 761 069 331 1 6 0.410 1 0 0 86 89 47 70
32 (25) 761 069 332 1 6 0.440 1 198 960 91 94 52 70
40 (32) 761 069 333 2 2 1.140 1 0 0 155 112 65 90
50 (40) 761 069 334 2 2 1.270 1 0 0 155 120 71 90
63 (50) 761 069 335 1 1 1.599 1 0 0 155 141 90 90
  
Valve PB concealed
Range of use
for finished mounting set ( e.g. GROHE / KLUDI / a. o. )
for electrofusion
Gasket: EPDM quality for potable water
Attention:
(do not use as drain valve)
(do not use for compressed air)
6212
d
[mm]
Code SP GP kg SID pcs.-Pal. Vol.-Pal.
 
20 (15) 761 069 342 6 6 0.396 1 0 0
25 (20) 761 069 343 1 6 0.410 1 198 960
32 (25) 761 069 344 6 6 0.450 1 0 0
 
 
60
Ball valves
Ball valve type 546 PVC-C / PB-Spigots
Range of use
for electrofusion
Attention:
non approval for potable water installation
working temperature max. +70°C
(do not use for compressed air)
* on request
5083
d
[mm]
DN
[mm]
PN EPDM
Code
SP GP kg SID pcs.-Pal. Vol.-Pal. L1
[mm]
L2
[mm]
z
[mm]
 
*20 15 10 761 066 343 1 0 0.178 3 0 0 95 190 33
*25 20 10 761 066 344 1 0 0.267 3 0 0 108 208 38
*32 25 10 761 066 345 1 0 0.403 3 0 0 118 218 39
*40 32 10 761 066 346 1 0 0.724 3 0 0 137 250 47
*50 40 10 761 066 347 1 0 0.988 3 0 0 147 263 49
*63 50 10 761 066 348 1 0 1.828 3 0 0 168 288 46
 
Ball valve type 546 PVC-C / PB-Flange Adaptor
Range of use
for socket fusion
Attention:
non approval for potable water installation
(do not use for compressed air)
5082
d
[mm]
DN
[mm]
PN EPDM
Code
SP GP kg kg/m SID pcs.-Pal. Vol.-Pal. L
[mm]
z
[mm]
  
20 15 16 761 066 337 1 10 0.160 0.160 1 0 0 95 33
25 20 16 761 066 338 1 10 0.245 0.245 1 0 0 108 38
32 25 16 761 066 339 1 10 0.365 0.365 1 0 0 118 39
40 32 16 761 066 340 1 6 0.660 0.660 1 0 0 137 47
50 40 16 761 066 341 1 6 0.890 0.890 1 0 0 147 49
63 50 16 761 066 342 1 4 1.650 1.650 1 0 0 168 46
  
  
Ball valve type 546 PP / PB-Flange Adaptor
Range of use
for socket fusion
applicable for compressed air till 6 bar
Attention:
non approval for potable water installation
5088
d
[mm]
DN
[mm]
PN EPDM
Code
SP GP kg kg/m SID pcs.-Pal. Vol.-Pal. L
[mm]
z
[mm]
  
20 15 16 760 000 337 1 10 0.115 0.115 1 0 0 95 33
25 20 16 760 000 338 1 10 0.180 0.180 1 0 0 108 38
32 25 16 760 000 339 1 10 0.255 0.255 1 0 0 118 39
40 32 16 760 000 340 1 6 0.440 0.440 1 0 0 137 47
50 40 16 760 000 341 1 6 0.610 0.610 1 0 0 147 49
63 50 16 760 000 342 1 4 1.145 1.145 1 0 0 168 46
  
  
61
Ball valve type 546 PP / PB-Spigots
Range of use
for electrofusion
applicable for compressed air till 6 bar
Attention:
non approval for potable water installation
working temperature max. +70°C
* on request
5089
d
[mm]
DN
[mm]
PN EPDM
Code
SP GP kg SID pcs.-Pal. Vol.-Pal. L1
[mm]
L2
[mm]
z
[mm]
  
*20 15 10 760 000 343 1 0 0.133 3 0 0 95 190 33
*25 20 10 760 000 344 1 0 0.202 3 0 0 108 208 38
*32 25 10 760 000 345 1 0 0.293 3 0 0 118 218 39
*40 32 10 760 000 346 1 0 0.504 3 0 0 137 250 47
*50 40 10 760 000 347 1 0 0.718 3 0 0 147 263 49
*63 50 10 760 000 348 1 0 1.323 3 0 0 168 288 46
  
PB flange adaptor
suitable to ball valve 546
5084
d
[mm]
Code SP GP kg kg/m SID pcs.-Pal. Vol.-Pal.
  
20 761 066 940 2 0 0.007 0.007 1 0 0
25 761 066 941 2 0 0.011 0.011 1 0 0
32 761 066 942 2 0 0.017 0.017 1 0 0
40 761 066 943 2 0 0.027 0.027 1 0 0
50 761 066 944 2 10 0.041 0.041 1 0 0
63 761 066 945 2 0 0.074 0.074 1 0 0
  
d
[mm]
L
[mm]
h
[mm]
D
[mm]
D1
[mm]
z
[mm]
     
20 20 6 27 34 5
25 23 7 33 44 5
32 25 7 41 50 5
40 27 8 50 61 5
50 30 8 61 73 5
63 33 9 76 90 5
     
62
Metal - butterfly valve type 037M
With hand lever
Model:
Housing: Aluminium ASTM S 12A, Rilsan® coated
Seatliner available in EPDM and FPM
d
[mm]
DN
[mm]
Inch PN kv-value
(Δp=1 bar)
[l/min]
Cv value
(Δp=1
psi)
[gal (US)
/min]
Disc: ductile
iron/Rilsan®
coated EPDM
Code
Disc: ductile
iron/Rilsan®
coated FPM
Code
  
63 50 2 10 3140 220 199 037 000 199 037 013
75 65 2 1
210 4570 320 199 037 001 199 037 014
90 80 3 10 7140 500 199 037 002 199 037 015
110 100 4 10 11710 800 199 037 003 199 037 016
140 125 5 10 18570 1300 199 037 004 199 037 017
160 150 6 10 27130 1900 199 037 005 199 037 018
225 200 8 10 47130 3330 199 037 006 199 037 019
  
d
[mm]
DN
[mm]
Inch PN kv-value
(Δp=1 bar)
[l/min]
Cv value
(Δp=1
psi)
[gal (US)
/min]
Disc: stainless
steel EPDM
Code
  
63 50 2 10 3140 220 199 037 200
75 65 2 1
210 4570 320 199 037 201
90 80 3 10 7140 500 199 037 202
110 100 4 10 11710 800 199 037 203
140 125 5 10 18570 1300 199 037 204
160 150 6 10 27130 1900 199 037 205
225 200 8 10 47130 3330 199 037 206
  
d
[mm]
DN
[mm]
Inch PN kv-value
(Δp=1 bar)
[l/min]
Cv value
(Δp=1
psi)
[gal (US)
/min]
Disc: stainless
steel FPM
Code
SID pcs.-Pal. Vol.-Pal.
  
63 50 2 10 3140 220 199 037 213 3 0 0
75 65 2 1
210 4570 320 199 037 214 3 0 0
90 80 3 10 7140 500 199 037 215 3 0 0
110 100 4 10 11710 800 199 037 216 3 0 0
140 125 5 10 18570 1300 199 037 217 3 0 0
160 150 6 10 27130 1900 199 037 218 3 0 0
225 200 8 10 47130 3330 199 037 219 3 0 0
  
d
[mm]
DN
[mm]
d3
[mm]
L
[mm]
L1
[mm]
L2
[mm]
H
[mm]
H1
[mm]
H2
[mm]
H3
[mm]

63 50 95 43 45 220 290 53 140 95
75 65 114 46 45 220 312 63 152 95
90 80 131 46 45 220 327 71 159 95
110 100 152 52 45 220 360 87 178 95
140 125 182 56 45 320 388 102 191 95
160 150 209 56 45 320 416 118 203 95
225 200 262 60 45 320 489 149 245 95

63
General Tools
Pipe shears3908
d-d
[mm]
Code SP kg
 
16 - 25 760 853 279 1 0.269
 
 
Cutter for protective pipe3911
d Code SP kg
 
16/20 760 853 273 1 0.087
 
 
PPC Plastic pipe cutter
For cutting plastic pipes d10 - d160
d-d
[mm]
Article Code SP kg Closest
inch
 
10 - 63 PPC 63, s max. = 7.2mm 790 109 001 0 0.710 1
8 - 2
50 - 110 PPC 110, s max. = 12.7mm 790 109 002 0 1.400 1 1
2 - 4
110 - 160 PPC 160, s max. = 19.0mm 790 109 003 0 2.220 4 - 6
 
Replacement cutting wheels
for plastic pipe cutter
d-d
[mm]
Article Code SP kg
 
10 - 63 SR 63 max. s=7,2 mm 790 109 011 0 0.004
50 - 110 SR 110/160 max. s=12,7 mm 790 109 012 0 0.017
110 - 160 SR 160 max. s=19,0 mm 790 109 013 0 0.023
 
KS Cleaner & Blue Paper
Code kg
 
1 litre 799 298 923 0.890
1 roll 790 099 175 1.000
 
 
64
Machines and tools for socket fusion jointing
SG 125 Socket fusion machine for fusion of PP, PE, PB
and PVDF pipes and fittings
Portable heating element - socket fusion machine for use in the workshop and on job
sites.
Dimension 20 - 125 mm
Base machine
Compact, sturdy design, distortion-free machine bed
Handwheel with torque locking mechanism for the slide movement
Heater
Electronic temperature control
High temperature accuracy over the entire heating surface
Additional standard equipment on the basic model
Universal, left and right prismatic clamping devices, complete, for clamping pipe and
fittings. Additional set of prismatic clamping devices for outer clamping of pipes avail-
able as an option.
Depth stop
V-shaped pipe support d 20 - 125 mm
Back stop
Machine specific tool set
Timer to clock fusion times
d-d
[mm]
Performance Code kg
20 - 125 115 V/1500 W 790 310 036 65.000
MSE 63/MSE 110 Socket fusion tools
For fusion jointing of PP, PE, PB and PVDF
Size range d 16-110 mm
Choice of electronic or thermostatic temperature control
Support for heating bushes and spigots of d 16 to 63 mm (110 mm)
Pick up for floor stand or table clamp
High-quality, non-stick PTFE-coating with long service life
Monitoring and setting of heating element temperature
High temperature accuracy over the entire heating surface
T = thermostatic temperature control / E = electronic temperature control
d-d
[mm]
Type Performance Code SP kg
 
16 - 63 MSE 63 T 115 V/800 W 790 105 096 0 2.075
16 - 63 MSE 63 E 115 V/800 W 790 105 097 0 2.145
16 - 110 MSE 110 T 115 V/1500 W 790 105 126 0 3.200
16 - 110 MSE 110 E 115 V/1500 W 790 105 127 0 3.200
 
 
Support
as a storage possibilty for Handheld heating element
5102
Code SP kg
 
761 066 801 1 0.970
 
65
Heating bushes
The INSTAFLEX heating bushes used for jointing Polybutene d75, d90, d110 are
also available at +GF+
5130
d
[mm]
Code SP kg
 
16 761 066 756 1 0.080
20 761 066 757 1 0.120
25 761 066 758 1 0.150
32 761 066 759 1 0.210
40 761 066 760 1 0.295
50 761 066 761 1 0.450
63 761 066 762 1 0.600
 
Heating spigots and bushes
d
[mm]
Code SP kg
 
75 790 101 093 0 1.157
90 790 101 094 0 1.697
110 790 101 095 0 2.090
 
 
Heating bushes for weld-in-saddle PB
d = Pipe dim.
5056
d
[mm]
Code SP kg Remarks
 
40 761 068 027 1 0.132 Drill bitt d20-d32
50 761 068 028 1 0.161 Drill bitt d20-d32
63 761 068 029 1 0.200 Drill bitt d20-d32
75 761 068 030 1 0.213 Drill bitt d20-d32
90 761 068 031 1 0.272 Drill bitt d20-d32
110 761 068 032 1 0.298 Drill bitt d20-d32
 
Drill bit for weld-in-saddle5057
d
[mm]
Code SP kg
 
20 - 32 761 068 039 1 0.120
40 - 50 761 068 040 1 0.130
 
 
Chamfering tool5302
d-d
[mm]
Code SP kg
 
25 - 63 761 066 794 1 0.650
75 - 110 761 066 836 1 0.830
 
 
Spare blades for Chamfering tool5303
d-d
[mm]
Code SP kg
 
25 - 110 761 066 795 1 0.016
 
 
66
Tempil Stick
Temperature
[°C]
Code SP kg
 
253 799 496 008 0 0.014
274 799 496 009 0 0.018
 
Timer5312
Code SP kg
 
761 066 798 1 0.042
 
 
Gloves5320
Code SP kg
 
761 066 799 1 0.115
 
 
Spanner
Tool to change the heating bushes
3948
SW
[mm]
Code SP kg
 
6760 854 906 1 0.070
 
Template, compression and fusion joints
to mark the clamp and coupler
5314
d-d
[mm]
Code SP kg
 
16 - 63 761 066 800 1 0.040
 
 
67
Tools for Compression Joints
Assembly tongs3905
d
[mm]
Code SP kg
 
16 - 20 760 853 743 1 0.420
25 760 869 950 1 0.418
 
Ratched spanner
for tightening and loosening of compression fittings d16 and d20
3954
SW
[mm]
d
[mm]
Code SP kg
 
24 16 760 854 916 1 0.280
27 20 760 854 917 1 0.586
 
68
Machines and Tools for Electro Fusion
Electrofusion control unit Type HWSG-3-110V
including welding cable for fittings without tool case, primary cable 110V, primary
cable 230V
Primary cable(3m) with Euro standard plug
Technical data: voltage 110V and 230V variable, power output max. 1500W,
Technical specifications
Frequency 47/65Hz, protection rate IP54, incl. power-supply cable 110V and 230V
(3m) with euroconnector
on request
6000
d-d
[mm]
Code SP kg Dimensions
[mm]
Size
[mm]
 
16 - 110 761 069 015 0 11.500 294 324
 
Welding cable angle PUR, for electrofusion fittings for
HWSG-3 110V
matches to HWSG 3 - 110V
on request
6001
d
[mm]
Code SP kg Length
[m]
 
16 - 110 761 069 016 1 0.300 3.00
 
Welding cable PUR straight, for electrofusion fittings for
HWSG-3 110V
matches to HWSG 3 - 110V
on request
6001
d-d
[mm]
Code SP kg Length
[m]
 
16 - 110 761 069 011 1 0.300 3.00
 
Primary cable 110V
on request
6005
Code SP kg Length
[m]
 
761 069 012 1 0.400 3.00
 
 
Primary cable 230V
on request
6005
Code SP kg Length
[m]
 
761 069 013 1 0.380 3.00
 
 
Template, electrofusion jointing5314
d-d
[mm]
Code SP kg
 
16 - 110 761 069 602 1 0.065
 
 
69
Tools for INSTAFLEX BIG
MSA 250 EX MULTI PLUS
Automatic Electrofusion Unit
Configuration:
only available in 230V
INSTAFLEX BIG/ELGEF/FUSEAL
including transportation case
including Barcodescanner
6008
d-d
[mm]
Code SP kg Type
 
125 - 225 761 069 007 0 16.800 MSA 250 EX MULTI
 
Heating bushes for weld-in-saddle PB
for heating element straight and 30°
d = Pipe dim.
5056
d
[mm]
Code SP kg Remarks
 
125 761 068 033 1 0.371 Drill bitt d20-d32
125 761 068 034 1 0.504 Drill bitt d40-d50
160 761 068 035 1 0.568 Drill bitt d20-d32
160 761 068 036 1 0.653 Drill bitt d40-d50
225 761 068 037 1 1.008 Drill bitt d20-d32
225 761 068 038 1 1.018 Drill bitt d40-d50
 
Rotary Peeler RS
This innovative Rotary Peeler RS is designed to use for universal peeling at the pipe
endfor electrofusion couplings, tees and elbows and as well as for electrofusion
saddles.
Suitable for peeling of pipes made out of PE80, PE100, PEX, PP.
Feature and your advantage:
Spring loaded peeling blade:Independent peeling quality of pipe ovality or tolerances
Pivoted mounted peeling blade:To compensate the shape of coiled pipe
Optimized cutting geometry:Defined chip thickness with cutting width overlap
One tool per dimension:Minimized swivel radius for peeling in narrow locations
Divisible tool:Peeling for saddles with the same tool
Peeling length:No limitation of peeling length
Guidance rolls:3 point support for dimensional optimized cutting feed, time saving
Time saving:Tool is always ready to use, it can be used for the next peeling without
setting the peeling blade back in its origin position
Your advantage:Time saving and highest repeatable peeling quality at smallest rota-
tion radius. No operator errors possible for change of dimension
Included:1 x Rotary Peeler RS, Transport case, Operating manual, Spare parts list
Article d
[mm]
Code SP kg
 
RS 125 125 790 136 007 0 1.650
RS 160 160 790 136 009 0 1.650
RS 225 225 790 136 012 0 1.850
 
70
TM 250 Basic machine
Tubular frame providing increased rigidity and easy movement of the machine on the
ground
4 lifting lugs
Metal shield providing protection of the main welding area
The movable (sliding) 3rd clamp allows easy and time saving fixing of bends or tees
without need of additional tools
Double-sided heating element pull-off mechanism to optimise the change-over phase
Clamps are hinged on the top side and tilting, whenever necessary the four clamps
can be quickly removed
Quick-action and drip-proof oil connections located in protected position
By rotating of the base machine a second operating position available
Type d-d
[mm]
Code SP kg
 
TM 250 75 - 250 790 151 001 0 50.000
 
71
GEORGE FISCHER SALES LIMITED (“George Fischer”)
CONDITIONS OF SALE (FOR GOODS AND SERVICES)
1 INTERPRETATION
1.1 Intheseconditionsofsalethefollowingwordswill(unlessthecontextotherwise
requires)havethefollowingmeanings:“Conditions”meanstheconditionssetoutbelow
andoverleaf.“Contract”meansanycontractbetweenGeorgeFischerandtheCustomerfor
thesaleofanyWorks.“Customer”meansthecompany,firm,bodyorpersonpurchasing
theWorks.“Customer’sProperty”meansanydies,tools,patterns,drawings,specifications,
designs,packagingsandanyotherequipment,goods,materials,instructionsorinforma-
tionsuppliedbyoronbehalfoftheCustomertoGeorgeFischerinconnectionwiththe
Works.“Goods”meansanygoodsagreedintheContracttobeprovidedbyGeorgeFischerto
theCustomer(includingbutnotlimitedtothewholeoranypartorpartsofthem,anyraw
materials,finishedorsemi-finishedmaterials,machinery,parts,spares,commoditiesand
anymaterials,articlesandcommoditiessuppliedinconnectionwiththeServices).“Services”
meansanyservicesagreedintheContracttobeprovidedbyGeorgeFischertotheCustomer
(includingbutnotlimitedtothewholeoranypartorpartsofthem).“Works”meansthe
Goodsand/ortheServices(asappropriate).
1.2 AnyreferenceintheseConditionstoanystatuteorstatutoryprovisionwill(unlessthe
 contextotherwiserequires)beconstruedasareferencetothatstatuteorstatutory
 provisionasmaybeamended,consolidated,modified,extended,re-enactedorreplacedfrom
 timetotime.
1.3 TheheadingsintheseConditionsareforreferenceonlyandwillnotaffecttheinterpretation
 oftheseConditions.
1.4 IntheseConditionsthewords“unlessotherwiseagreedinwriting”willmeanunlessother
 wiseagreedinwritingandsignedbyadirectororcommercialmanagerofGeorgeFischer.
1.5 GeorgeFischerreservestherightatanytimetocorrectanyclerical,typographicalorother
 similarerrorsmadebyitsemployees.
2 QUOTATIONS
2.1 Anyquotation(whetherwrittenororal)isgivenonthebasisthatnocontractwill
 comeintoexistenceotherwisethaninaccordancewiththeprovisionsofclauses3.5and3.6.
2.2 Unlessotherwiseagreedinwritinganyquotationisvalidonlyforaperiodof45daysfromits
 dateofissueprovidedthatGeorgeFischerhasnotpreviouslywithdrawnitbywrittenororal
 noticetotheCustomer.
2.3 AnyquotationisbasedontheinstructionsandinformationprovidedbytheCustomerand 
 GeorgeFischerreservestherighttoamendthequotationatanytimetocoveranyincreasein
 pricewhichmayariseasaresultofadditionalorincompleteinstructionsorinformation.
3 APPLICATION OF TERMS
3.1 (Subjecttoclause3.4)theseConditionsaretheonlyconditionson
 whichGeorgeFischerispreparedtodealwiththeCustomerandtheywillapplytoall
 Contractstotheexclusionofanyothertermsandconditionsincludingbutnotlimitedto
 thosewhichtheCustomerpurportstoapply.
3.2 Notermsorconditionsendorsedupon,deliveredwith,referredtoorstipulatedorcontained
inanypurchaseorderorothersimilardocumentdeliveredorsentbytheCustomerto 
 GeorgeFischerwillformpartoftheContract.
3.3 AnyreferenceoverleaftotheCustomer’spurchaseorderorothersimilardocument
 willnotbedeemedtoimplythatanytermsorconditionsendorsedupon,delivered
 with,referredtoorstipulatedorcontainedinsuchpurchaseorderorothersimilar
 documentwillhaveeffecttotheexclusionoramendmentoftheseConditions.
3.4 AnyvariationtotheseConditionsandanyrepresentationabouttheWorkswillonlybe
effectiveifitisagreedinwriting,containsaspecificreferencetotheseConditionsand 
 issignedbyadirectororcommercialmanagerofbothparties.
3.5 EachpurchaseorderforWorksissuedbytheCustomerwillbedeemedtobeanofferbythe
 CustomertopurchaseWorkssubjecttotheseConditions.
3.6 NopurchaseorderplacedbytheCustomerwillbedeemedtobeacceptedbyGeorge
 FischeruntilawrittenacknowledgementoforderisissuedbyGeorgeFischeror(if
 earlier)GeorgeFischercommencestheWorksorsuppliestheWorkstotheCustomer.
3.7 TheCustomermustensurethatthecontentofitsorderandanyapplicablespecificationare
 completeandaccurate.
3.8 Unlessotherwiseagreedinwritingalldrawings,illustrations,descriptions,specifications,
 technicaldata,advertisingandothersimilarinformationissuedbyGeorgeFischeror
 containedinGeorgeFischer’scatalogues,brochures,tradeliterature,pricelistsorother
 similarpublishedmaterialsareissuedorpublishedonlyforthepurposeofgivingan
 approximateideaoftheWorksdescribedinthemandwillnotformpartoftheContract.
3.9 AnypurchaseorderwhichhasbeenacceptedbyGeorgeFischerinaccordancewith
 clause3.5and3.6mayonlybeamended,cancelled,postponedorvariedbytheCustomer
 withthepriorwrittenconsentofGeorgeFischerandontermsthattheCustomerwill
 indemnifyGeorgeFischerinfullagainstalllosses(includingbutnotlimitedtolossofprofit),
 costs,damages,chargesandexpensesincurred(directlyorindirectly)byGeorgeFischerasa
 resultofsuchamendment,cancellation,postponementorvariation.
4 DELIVERY
4.1 AnytimesspecifiedoragreedbyGeorgeFischerforthedeliveryoftheWorksare
giveningoodfaithbutareanestimateonly.IfnotimeisspecifiedoragreedbyGeorge 
 Fischerdeliverywilltakeplacewithinareasonabletime.Unlessotherwiseagreedinwriting
 timeforthedeliveryoftheWorkswillnotbeoftheessenceoftheContract.
4.2 GeorgeFischerwilluseitsreasonableendeavourstodelivertheWorkswithinthetimesset
 outinclause4.1butGeorgeFischerwillnotbeliablefortheconsequencesofanydelayor
 failuretodeliverifthedurationofthedelayisnotsubstantialorifthedelayorfailureisdue
toanycircumstancesbeyondGeorgeFischer’sreasonablecontrolorofanunexpectedor 
 exceptionalnature.
4.3 (Subjecttotheprovisionsofclause4.4deliverywillbedeemedto
 takeplacewhentheWorksaredeliveredtotheCustomeratsuchplaceasthepartiesmay
 agreeexceptthatdeliverytoacarrierforthepurposeoftransmissiontotheCustomerwill
 bedeemedtobedeliverytotheCustomerandsections32(2)and(3)oftheSaleofGoodsAct
 1979willnotapply.
4.4 IfGeorgeFischeragreestopermittheCustomertocollecttheWorksfromGeorgeFischer’s
 placeofbusinessthendeliverywillbedeemedtotakeplacewhenGeorgeFischernotifies
 theCustomerthattheWorksarereadyforcollectionandunlessotherwiseagreedinwriting
 theCustomerwillcollecttheWorkswithin3workingdaysoftheissueofsuchnotice.
4.5 GeorgeFischerwilluseitsreasonableendeavourstoensurewherenecessarythattheWorks
willbepackedsoastobeadequatelyprotectedagainstdamageinnormalconditionsof 
 transitofusualduration.GeorgeFischerwillmakesucharrangementsforthecarriageand
 insuranceoftheWorksasitagreeswiththeCustomer.
4.6 GeorgeFischermaydelivertheWorksininstalments.Deliveriesoffurtherinstalmentsmay
 bewithhelduntiltheWorkscomprisedinearlierinstalmentshavebeenpaidforinfull.
 DefaultbyGeorgeFischer(howsoevercaused)inrespectofoneormoreinstalmentswillnot
 entitletheCustomertoterminatetherelevantContractasawhole.
4.7 IntheeventofanydelayinthedeliveryofanyGoodsand/ortheperformanceofanyServices
 whichareattributabletotheCustomer’sactsoromissionsthen:
 (a)deliveryoftheGoodsand/orperformanceoftheServiceswillbedeemedtohave
 takenplaceatthetimeatwhichbutforsuchdelayordelayssuchdeliveryorper
 mancewouldhavetakenplaceandanyextracostsincurredasaresultofsuchdelay
 ordelayswillbeaddedtotheContractpriceandwillbepayablebytheCustomer;and
 (b)GeorgeFischermaysellsuchGoods28daysaftersuchdelayanddeductanymonies
 payabletoGeorgeFischerbytheCustomerfromthesaleproceedsandaccounttothe
 CustomerforanyexcessorchargetheCustomerforanyshortfall.
4.8 WheretheWorksaretobesuppliedfromstocksuchsupplyissubjecttotheavailabilityofthe
 stockatthedateofdelivery.
4.9 OndeliverytotheCustomerallWorksshouldbeexamined.(Subjecttoclause8.2)George
 Fischerwillnotbeliableforanyshortagesinornon-deliveryoftheWorks(evenifcaused
 byGeorgeFischer’snegligence)unlessthesameisnotifiedinwritingbytheCustomerto
 GeorgeFischer(togetherwithallrelevantdetails)within14daysoftheactualoranticipated
 dateofdelivery(asappropriate).SubjecttosuchnoticebeingprovidedGeorgeFischerwill,
ifitisreasonablysatisfiedthatanyWorkshavenotbeendeliveredasaresultofGeorge 
 Fischer’sfault(initssolediscretion)eitherarrangefordeliveryassoonasreasonably
 possibleorgivecredit(attheprorataContractprice)totheCustomerforsuchWorks.Any
 shortagesinornon-deliveryofpartoftheWorkswillnotaffecttheContractinrespectofthe
 otherpartsoftheWorks.
4.10 IfGeorgeFischercomplieswithclause4.9itwill(subjecttoclause8.2)havenofurther
 liability(incontract,tort(includingbutnotlimitedtonegligence)orotherwise)forsuch
 shortagesornon-delivery.
4.11 WhilstGeorgeFischerwillusereasonableendeavourstosupplytheexactquantityof
 theWorksorderedbytheCustomer,GeorgeFischermaysupplyandtheCustomer
 willacceptupto10%moreorlessthantheexactquantityordered.Aproratacharge
 orallowanceattheContractpricewillbemadetocoveranysuchvariation.
4.12 TheCustomer(atitsownexpense)willensurethattheplacewheredeliveryofthe
 GoodsorperformanceoftheServicesistotakeplaceisadequateandappropriateforsuch
deliveryorperformanceandwillprovidesuchaccess,equipment,facilities,protection, 
 manuallabourandinformationasmayberequiredtoenableGeorgeFischertoperformits
 obligationsundertheContract.
5 RISK AND OWNERSHIP
5.1 UnlessotherwiseagreedinwritingtheWorksareattheriskoftheCustomerfromthe
 timeofdeliveryordeemeddeliverytotheCustomer(asappropriate)andloadingandoff
 loading(asappropriate)willbeattheCustomer’srisk.Section20(2)oftheSaleofGoodsAct
 1979willnotapply.
5.2 (NotwithstandingthatriskintheWorkswillpasstotheCustomerinaccordancewith
 theprovisionsofclause5.1)ownershipoftheWorks(bothlegalandequitable)willonlypass
 totheCustomer(otherthanwhenownershipisproperlyvestedinsomeotherpersonbythe
 operationofanystatute)whenGeorgeFischerhasreceivedinfull(incashorclearedfunds)
 allmoniesduetoitfromtheCustomer:
 (a)inrespectoftheWorks;and
 (b)allothersumswhichareorwhichbecomeduetoGeorgeFischerfromtheCustomeron
 anyaccount.
5.3 UntilownershipoftheWorkshaspassedtotheCustomerunderclause5.2,theCustomer
 will:
 (a)holdtheWorksonafiduciarybasisasGeorgeFischer’sbailee;
 (b)keeptheWorksfreefromanycharge,lienorotherencumbrance;
 (c)storetheWorks(atnocosttoGeorgeFischer)separatelyfromallothermaterials
 oftheCustomeroranythirdpartyinsuchawaythattheyremainreadilyidentifiable
 asGeorgeFischer’sproperty;
 (d)notdestroy,defaceorobscureanyidentifyingmarkontheWorksortheirpackaging;
 (e)maintaintheWorksinasatisfactorycondition,insuredonGeorgeFischer’sbehalf
 fortheirfullpriceagainstallriskstothereasonablesatisfactionofGeorgeFischerandon
 requestproducesuchpolicyofinsurancetoGeorgeFischer;
 (f)holdallproceedsoftheinsurancereferredtoinclause5.3
 (e)ontrustforGeorgeFischerandnotmixitwithanyothermoneyorpaytheproceedsinto
 anyoverdrawnbankaccount;and
 (g)notattachtheWorkstoanyrealpropertywithoutGeorgeFischer’sconsent.
5.4 TheCustomermayresell,useorotherwisedisposeoftheWorksbeforeownershiphas
 passedtoitonlyifanysuchsale,useordispositionwillbeeffectedintheordinarycourseof
 theCustomer’sbusinessandwillbeasale,useordispositionofGeorgeFischer’sproperty
 ontheCustomer’sownbehalfandtheCustomerwilldealasprincipal.
5.5 GeorgeFischermaywhiletheowneroftheWorks(andwithoutprejudicetoanyotherrights
 itmayhaveunderorbyvirtueoftheseConditions)demandtheimmediatereturnofthe
 WorksatanytimeandtheCustomerwillforthwithcomplywithsuchdemandandbearthe
 expensesforsuchreturn.
5.6 TheCustomergrantstoGeorgeFischer(oritssuccessorsintitlefortheWorks)and
theirrespectiveemployeesandagentsanirrevocablelicencetoenteratanytimeany 
 premiseswheretheWorksareormaybesituatedforthepurposeofinspectingor
 removinganysuchWorkstheownershipinwhichhasremainedwithGeorgeFischer.
5.7 GeorgeFischerwillbeentitledtorecoverpaymentfortheWorksnotwithstandingthat
 ownershipofanyoftheWorkshasnotpassedfromGeorgeFischer.
5.8 TheWorkswillbedeemedsoldorusedintheorderdeliveredtotheCustomer.
6 PRICE AND PAYMENT
6.1 ThepricestatedintheContractisbasedonthecosttoGeorgeFischerofmaterials,
 fuel,power,transport,taxes,duties,services,labourandallothercostsatthedateof
 GeorgeFischer’squotation,acknowledgementoforderorsupply(whichever
 isearlier).IfatthedateofdeliveryordeemeddeliveryoftheWorkstherehasbeen
 anyincreaseinalloranyofsuchcosts,thepricepayablefortheWorksmaybe
 increasedbyGeorgeFischeraccordingly.
6.2 Quotationsgiveninacurrencyotherthansterlingarebasedontherateofexchange
 atthetimeofquotingand(unlessotherwiseagreedinwritingbetweentheparties)theprice
 maybesubjecttorevisionifanydifferentrateofexchangeisrulingatthedateofinvoice.
6.3 (Unlessotherwiseagreed)thepricefortheWorksisexclusiveofanyvalueaddedtax
(andanyothertaxordutyrelatingtothemanufacture,transportation,saleordelivery 
 oftheWorks)andanycostsorchargesinrelationtoexportand/orimport,packaging,
loading,unloading,carriageandinsurance.Suchcostsandexpenseswillbepaidbythe 
 CustomerinadditiontothepricefortheWorksatthesametimethatitisduetopayforthe
 Works.
6.4 WhereGeorgeFischeragrees(initsdiscretion)tobringforwardthedateofdeliveryofthe
 WorksattheCustomer’srequestanyovertimeorotheradditionalcostsreasonablyincurred
 byGeorgeFischershallbechargedtotheCustomerinadditiontotheContractprice.
6.5 GeorgeFischermayinvoicetheCustomerfortheWorksatanytimeafterthedeliveryofthe
 Worksorthedeliveryofanyinstalment(asappropriate).Ifanydeliveryispostponedatthe
requestorbythedefaultoftheCustomerthenGeorgeFischermaysubmititsinvoiceat 
anytimeaftertheWorksarereadyfordeliveryorwouldhavebeenreadyintheordinary 
 coursebutfortherequestordefaultonthepartoftheCustomer.
6.6 CustomerswhohavebeengrantedbyGeorgeFischer(initssolediscretion)acreditaccount
 facilitywillpaythepricewithin30daysoftheendofthemonthinwhichtheWorksaredes
 patched.GeorgeFischermay(initssolediscretion)amendthetermsoforwithdraw
suchcreditaccountfacilityatanytimewithoutnoticewithimmediateeffectandonsuch 
 withdrawalallamountsdueoraccruingtoGeorgeFischerundertheContractwillbecome
 immediatelypayabledespiteanyotherprovisionoftheseConditions.
6.7 Customerswhohavenotbeengrantedacreditaccountfacilitywillpaytheprice5working
 dayspriortodeliveryoftheWorks.
6.8 NopaymentwillbedeemedtohavebeenreceiveduntilGeorgeFischerhasreceivedcleared
 funds.
6.9 TimeforpaymentwillbeoftheessenceoftheContractandtheCustomerwillindemnify 
 GeorgeFischeragainstallexpensesandlegalcostsincurredbyGeorgeFischerinrecovering
 overdueamounts.
6.10 AllpaymentspayabletoGeorgeFischerundertheContractwillbecomedueimmediatelyon
 terminationofthisContractdespiteanyotherprovisionoftheseConditions.
6.11 TheCustomerwillmakeallpaymentsdueundertheContractwithoutanydeductionwhether
 bywayofset-off,counterclaim,discount,abatementorotherwiseunlesstheCustomerhasa
 validcourtorderrequiringanamountequaltosuchdeductiontobepaidbyGeorgeFischer
 totheCustomer.
6.12 IftheCustomerfailstopayGeorgeFischeranysumduepursuanttotheContractthe
 CustomerwillbeliabletopayinteresttoGeorgeFischeronsuchsumfromtheduedate
 forpaymentatanannualrateof4%abovethebaselendingrateofHSBCBankplcfromtime
 totimeaccruingonadailybasisuntilpaymentismadeinfull(whetherbeforeorafterany
 judgement).Inthealternative,GeorgeFischerinisabsolutediscretion,reservestherightto
 claiminterestandcompensationpaymentsundertheLatePaymentofCommercialDebts
 (Interest)Act1998.
6.13 Withoutprejudicetotheprovisionsofclause6.12iftheCustomerfailsorGeorgeFischer
 reasonablybelievesthattheCustomerwillfailtopayfortheWorkwhendueGeorgeFischer
 maydemandpaymentofalloutstandingbalanceswhetherdueornot,treattheContractas
 repudiatedbytheCustomerorsuspendanyfutureperformanceoftheContractoranyother
 contractwiththeCustomeruntilalloverduesumshavebeenpaid.
7 QUALITY
7.1 GeorgeFischerwarrants(subjecttotheprovisionsofthisclause7)that:
 (a)ondeliveryoftheGoodsandforaperiodof12monthsfromthedateofdelivery,theGoods
 will:
(i)beofsatisfactoryquality,withinthemeaningoftheSaleofGoodsAct1979(as 
  amended);and
  (ii)bereasonablyfitforanyparticularpurposeforwhichtheWorksarecommonly
  suppliedorarebeingbought(iftheCustomerhasmadeknownthatpurposeto
  GeorgeFischerinwritingandGeorgeFischerhasconfirmedinwritingthatitis
  reasonablefortheCustomertorelyontheskillandjudgementofGeorgeFischer);
 (b)andtheServiceswillbeperformedwithreasonableskillandcarebyproperly
 qualifiedandexperiencedpersons.
GEORGE FISCHER SALES LIMITED (“George Fischer”)
CONDITIONS OF SALE (FOR GOODS AND SERVICES)
The above Terms of Business effective from 29th June 2007
7.2GeorgeFischerwillnotbeliableforanybreachofanyofthewarrantiesinclause7.1unless:
 (a)theCustomergiveswrittennoticeofthedefecttoGeorgeFischerwithin28daysofthedate
 whentheCustomerdiscoversoroughtreasonablytohavediscoveredthedefect;
 (b)(ifthedefectisasaresultofdamageintransit)theCustomergiveswrittennoticeofthe
 defecttothecarrierinthemannerandwithintheappropriatetimelimitassetoutinthe
 carrier’stermsofbusiness;andGeorgeFischerisgivenareasonableopportunityafter
 receivingsuchnoticetoexaminesuchWorksandtheCustomer(ifrequestedtodosoby
 GeorgeFischer)returnssuchWorkstoGeorgeFischer’splaceofbusiness(attheCustomer’s
 cost)fortheexaminationtotakeplacethere.
7.3GeorgeFischerwillnotbeliableforabreachofanyofthewarrantiesinclause7.1whereand
 totheextentthat:
 (a)thedefectarisesfromtheCustomer’sPropertyorasaresultoftheCustomer’snegligence;
(b)thedefectarisesasaresultoffairwearandtear,misuse,wilfuldamage,orabnormal 
 workingconditions;
(c)thedefectarisesasaresultofanyparts,materialsorequipmentnotmanufacturedor 
 workmanshipnotperformedbyGeorgeFischer;
 (d)theCustomermakesanyfurtheruseofsuchWorksaftergivingwrittennoticeofthedefect;
 (e)thedefectarisesbecausetheCustomerhasfailedtofollowGeorgeFischer’sinstructions
(whetheroralorinwriting)astothestorage,assembly,installation,commissioning,use, 
 processing,handlingormaintenanceoftheWorksor(iftherearenone)goodtradepractice;
(f)thedefectarisesasaresultofanyinstallation,testingorcommissioningoftheWorks 
 performedbytheCustomeroranythirdparty;or
 (g)thedefectarisesasaresultofanyalteration,servicingorrepairoftheWorksnotmadeby
 GeorgeFischerandwithoutthewrittenconsentofGeorgeFischer.
7.4(Subjecttoclauses7.2and7.3)ifanyoftheWorksdonotconfirmwithanyofthewarranties
 setoutinclause7.1GeorgeFischerwillatitsoptionandcostrepairorreplacesuchGoods(or
 thedefectivepart),re-performsuchServicesorrefundthepriceofsuchWorksattheprorata
 Contractrate.
7.5IfGeorgeFischercomplieswithclause7.4itwill(subjecttoclause8.2)havenofurther
 liability(incontract,tort(includingbutnotlimitedtonegligence)orotherwise)forbreachof
 anyofthewarrantiesinclause7.1inrespectofsuchWorks.
7.6AnyGoodsreplacedbyGeorgeFischerinaccordancewiththeprovisionsofclause7.4will
 belongtoGeorgeFischerandanyrepairedorreplacementGoodswillbeguaranteedonthese
 termsfortheunexpiredportionoftheoriginal12monthwarrantyperiod.
8 LIMITATION OF LIABILITY
 THEPRICESCHARGEDFORTHEWORKSAREBASEDSTRICTLYONTHEUNDERSTANDING
 OFACCEPTANCEBYTHECUSTOMEROFTHEPROVISIONSINTHECONTRACTFORTHE
 LIMITATIONOFGEORGEFISCHER’SLIABILITY.SHOULDTHECUSTOMERWISHGEORGE
 FISCHERTOACCEPTADDITIONALLIABILITYTHISMAYBEDISCUSSEDBETWEENTHE
 PARTIESANDTHEPRICEMAYBEINCREASEDACCORDINGLY.
8.1Allwarranties,conditionsandothertermsimpliedbystatuteorcommonlaw(exceptforthe
 conditionsimpliedbysection12oftheSaleofGoodsAct1979andsection2oftheSupplyof
GoodsandServicesAct1982)are,tothefullestextentpermittedbylaw,excludedfromthe 
 Contract.
8.2NothingintheseConditionsexcludesorlimitstheliabilityofGeorgeFischerforfraudulent
 misrepresentationorforanydeathorpersonalinjurycausedbyGeorgeFischer’snegligence
 orforanybreachoftheconditionsimpliedbysection12oftheSaleofGoodsAct1979andsec
 tion2oftheSupplyofGoodsandServicesAct1982.
 THECUSTOMER’SATTENTIONISINPARTICULARDRAWNTOTHEPROVISIONSOFCLAUSES
 8.3AND8.4
8.3(Subjecttoclause8.1and8.2)GeorgeFischerwillnotbeliabletotheCustomerincontract,
 tort(includingbutnotlimitedtonegligence),misrepresentationorotherwiseforany:
 (a)economiclossofanykind(includingbutnotlimitedtodirectorindirectlossofprofit,
 business,contracts,revenueoranticipatedsavings):
 (b)damagetotheCustomer’sreputationorgoodwill:
 (c)productrecallcosts;or
(d)anyspecial,indirectorconsequentiallossordamage(evenifGeorgeFischerhasbeen 
 advisedofsuchlossordamage)arisingoutoforinconnectionwiththeContract.
8.4(Subjecttotheprovisionsofclause8.2and8.3
9 THE CUSTOMER’S PROPERTY
9.1WhileGeorgeFischerwilltakereasonablecareoftheCustomer’sPropertywhilstitisin 
 GeorgeFischer’spossession,controlorcustodytheCustomer’sPropertywill(unless
 otherwiseagreedinwriting)remainattheCustomer’sriskandallreplacementsand
 alterationsofandrepairstotheCustomer’sPropertywillbetheCustomer’sresponsibility.
9.2GeorgeFischerwillnotbeliableforanylossordamagetotheCustomer’sPropertyunless
 suchlossordamagearisesasadirectresultofGeorgeFischer’snegligence.WhereGeorge
 Fischerisliableunderthisclause9.2GeorgeFischer’sliabilitytotheCustomerwillbelimited
 totheactualcostofthereplacementorrepairofthelossordamagetotheCustomer’s
 Property.
9.3TheCustomerwillensurethattheCustomer’sPropertyisingoodconditionandsuitablefor
 usebyGeorgeFischerintheperformanceoftheContractandwhileGeorgeFischerwill
 usereasonableendeavourstoverifyanyrelevantaspectsoftheCustomer’sPropertyno
 responsibilityisacceptedbyGeorgeFischerforitsaccuracy.
9.4AnydefectintheWorkswhichisdueinwholeorinparttotheCustomer’sPropertywillnot
 entitletheCustomertoterminatetheContract,rejecttheWorks,makeanydeductionsfrom
 theContractpriceorclaimdamagesinrespectofsuchdefect.
9.5TheCustomerwillkeepGeorgeFischerindemnifiedinfullagainstallliability,loss,damage,
 injury,claim,action,demand,expenseorproceedingawardedagainstorincurredbyGeorge
 FischerasaresultoforinconnectionwiththeusebyGeorgeFischeroftheCustomer’s
 Propertyunlesssuchliability,loss,damage,injury,claim,action,demand,expenseor
 proceedingistheresultofGeorgeFischer’snegligentactsoromissions.
10 TOLERANCES AND TESTS
10.1Unlessotherwiseagreedinwritinggauges,weights,chemicalcompositionandanalysis,
 quantitiesandsizeswill,sofaraspossible,beadheredtobutreasonableexcessesand
 deficiencieswillbeacceptedbytheCustomer,whowillnotbeentitledtorejectanyWorkson
 thegroundthattheyarenotpreciselyasspecified.
10.2Unlessotherwiseagreedinwriting,alltests,testpiecesandinspectionsrequiredbythe 
 CustomerandagreedbyGeorgeFischerwillbechargedextra.Alltestsandinspectionswill
 takeplaceunderGeorgeFischer’sstandardtestingarrangements,andsuchtestswillbe
 final(exceptinthecaseofmanifesterror).Alltestsaresubjecttoanalyticaltolerances.
10.3TheCustomermayattend(atitsowncost)alltestsprovidedthatitnotifiesGeorgeFischerin
 writingofitsintentiontodoso.TheCustomerwillthenbegivennotlessthan5working
 day’spriornoticeoftheproposeddateandtimeofanytestand,iftheCustomerfailsto
 attend,thetestwillproceedinitsabsencealthoughitwillbedeemedtohavebeenmadein
 itspresence.
11 OWNERSHIP OF TOOLING
11.1Wherepatterns,dies,tools,drawingsandequipmentarenotsuppliedbytheCustomer,only
 thosewhicharespeciallymadebyGeorgeFischerandseparatelychargedtotheCustomerin
 full,will,whenpaidforbytheCustomer,becomethepropertyoftheCustomer.
11.2GeorgeFischerreservestherighttodestroyorotherwisedisposeofpatterns,dies,tools, 
 drawingsandequipmentinitspossession,controlorcustody(whetherornotthepropertyof
 theCustomer)fromwhichtheCustomerhasnotrequiredanyWorkstobemadeforaperiod
 of12monthsormore.
12 PACKING CASES AND PACKING MATERIALS
12.1Unlessotherwiseagreedinwritingpackingcasesandpackingmaterialswillnotbecharged
 extrabut,wherestatedtobereturnable,willbereturnedtoGeorgeFischeringood
 condition,withinonemonthofreceiptbytheCustomer.Wherenotreturnable,theCustomer
 willdisposeofallpackinginaccordancewithallregulations(whetherstatutoryorotherwise)
 relatingtotheprotectionoftheenvironment.
13 CONFIDENTIALITY
13.1TheCustomerwillkeepconfidentialalltechnicaldata,commercialinformation,
knowhow,specifications,inventions,processes,initiativesandotherinformationwhichis 
ofaconfidentialnatureandwhichhasbeendisclosedtotheCustomerbyGeorgeFischer 
 and/oranymemberoftheGeorgeFischergroupand/oritsagentsandanyotherconfidential
informationconcerningthebusinessofGeorgeFischerand/oranymemberoftheGeorge 
 FischergrouporitsproductswhichtheCustomermayobtain(“ConfidentialInformation”).
13.2TheCustomerwillrestrictdisclosureoftheConfidentialInformationtosuchofitsemployees,
 agentsorsubcontractorsasneedtoknowthesameandwillensurethatsuchemployees,
 agentsorsubcontractorsaresubjecttoequivalentobligationsofconfidentialityasbindthe
 Customer.
13.3TheCustomerwillnotwithoutthepriorwrittenconsentofGeorgeFischerpublishordisclose
 theConfidentialInformationtoanythirdpartyormakeanyuseoftheConfidential
 InformationexcepttotheextentnecessarytoimplementtheContract.
14 INTELLECTUAL PROPERTY
14.1TheCustomerwillkeepGeorgeFischerindemnifiedinfullagainstallliability,loss,damage,
 injury,claim,action,demand,expenseorproceedinginrespectofanyinfringementor
 allegedinfringementofanypatent,registereddesign,unregistereddesign,designcopyright,
 trademarkorotherindustrialorintellectualpropertyrightsresultingfromanyusebyGeorge
 FischeroftheCustomer’sPropertyoranycompliancebyGeorgeFischerwiththeCustomer’s
 instructions,whetherexpressorimplied.
14.2(Unlessotherwiseagreedinwriting)ownershipinallintellectualpropertyrights
 subsistingin,resultingfromorrelatingtotheWorksoranyassociatedplans,descriptions,
 blueprints,designs,technicalinformation,drawings,documentsorspecifications(except
 wheretheserelatesolelytotheCustomer’sProperty)willvestinorbeassignedtoGeorge
 Fischer.IftheCustomerinanywayacquiresanysuchrightsitwillpromptlyinformGeorge
 FischerandtakesuchstepsasGeorgeFischermayreasonablyrequiretoassignsuchrights
 orvestsuchtitleinGeorgeFischer.
14.3NothingintheseConditionswillbeconstruedasanyrepresentationorwarrantybyGeorge
 Fischerthatthedesign,manufacture,useorsaleoftheWorksisnotaninfringementofany
 thirdpartyintellectualpropertyrights.
15 TERMINATION
15.1GeorgeFischermayterminatetheContract(andallothercontractsbetweenGeorgeFischer
 andtheCustomer)immediatelyif:
 (a)theCustomerfailstopaythepriceontheduedate;
(b)theCustomerisinbreachofanytermoftheContractandhasfailedtoremedysuch 
 breachwithin28daysofreceiptofwrittennoticespecifyingthebreachandrequiringittobe
 remedied;
 (c)thereisamaterialchangeintheownershiporcontroloftheCustomer;or
 (d)theCustomeriswounduporbecomesinsolventorhasareceiveroradministrative
 receiverappointedorsufferstheappointmentorthepresentationofapetitionforthe
 appointmentofanadministrationoranyequivalentoranalogouseventoccursinanyrelevant
 jurisdiction.
15.2TheterminationoftheContract(howsoeverarising)willbewithoutprejudicetoanyrights 
 andremedieswhichmayhaveaccruedtoeitherparty.
15.3AnyConditionswhichimpliedlyhaveeffectafterterminationorexpirywillcontinuetobe 
 enforceablenotwithstandingterminationorexpiry.
16 EXPORT SALES
16.1WheretheWorksaresuppliedforexportfromtheUnitedKingdomtheprovisionsofthis
clause16will(subjecttoanyspecialtermsagreedinwritingbetweentheparties)apply 
 despiteanyotherprovisionoftheseConditions.
16.2TheUniformLawsonInternationalSalesAct1967willnotapply.
16.3Unlessotherwiseagreedinwritingthecurrencywillbepoundssterling.TheCustomerwill
establishandmaintaininfavourofGeorgeFischeranirrevocableandconfirmedletterof 
 creditinEnglishwithaUKclearingbankpayableondraftsdrawnatsightonpresentation
 tothebankbyGeorgeFischerofacertifiedcopyofGeorgeFischer’sinvoice.Allbank
 chargesandotherexpensesinrelationtotheletterofcreditwillbebornebytheCustomer.
16.4UnlessotherwiseagreedinwritingWorkswillbesoldC.I.F(asdefinedinINCOTERMS2000
 Edition).
16.5TheCustomerwillberesponsibleforcomplyingwithandshallcomplywithanylegislationor
 regulationgoverningtheexportoftheWorks:
 (a)fromtheUnitedKingdom;and/or
 (b)(wheretheWorksaresourcedfromacountryotherthantheUnitedKingdom)fromsuchc
 countryandtheimportationoftheWorksintothecountryofdestinationandforpaymentof
 anyrelevantdutiesortaxeswhetherpayablebytheCustomerorGeorgeFischer.
16.6Unlessotherwiseagreedinwritingpackingcasesandpackingmaterialswillbecharged
 extrabut,wherestatedtobereturnable,willbecreditedinfullonreturntoGeorgeFischer’s
 placeofbusiness(carriagepaid)ingoodcondition,withinonemonthofreceiptbythe
 Customer.Wherenotreturnable,theCustomerwilldisposeofallpackinginaccordancewith
 allregulations(whetherstatutoryorotherwise)relatingtotheprotectionoftheenvironment.
17 LIEN
 GeorgeFischerwillhaveinrespectofunpaiddebtsduetoitfromtheCustomeragenerallien
 onallpropertyoftheCustomerwhichisinGeorgeFischer’spossessionforwhateverreason
 andwhetherworkeduponornot.
18 ASSIGNMENT AND SUBCONTRACTING
18.1TheCustomerwillnotwithoutthepriorwrittenconsentofGeorgeFischerassignortransfer
 theContractoranypartofittoanyotherperson.
GeorgeFischermaywithoutthepriorwrittenconsentoftheCustomerassign,transferor 
 subcontracttheContractoranypartofittoanyotherperson.
19 GENERAL
19.1EachrightorremedyofGeorgeFischerundertheseConditionsiswithoutprejudicetoany
 otherrightorremedywhichGeorgeFischermayhaveundertheseConditionsorotherwise.
19.2Anynoticeordocumentshallbedeemedserved,ifdeliveredbyhand,atthetimeofdelivery,
ifposted,48hoursafterpostingandifsentbyfacsimiletransmission,atthetimeoftrans 
 mission.GeorgeFischermayalsosendanoticeordocumentbyelectroniccommunicationin
 ane-mailaddressnotifiedtoGeorgeFischerbytheCustomer.Suchnoticeordocument
 shallbedeemedservedifsentbye-mailtransmission48hoursafterthetimeof
 transmission.
19.3Theillegality,invalidityorunenforceabilityofanyprovisionoftheseConditionswillnotaffect
 thelegality,validityorunenforceabilityofanyotherprovisionsoftheseConditions.
19.4FailureordelaybyeitherpartyinexercisinganyrightorremedyprovidedbytheContractor
 bylawwillnotbeconstruedasawaiverofsuchrightorremedyorawaiverofanyotherright
 orremedy.
19.5ApersonwhoisnotapartytotheContractwillhavenorightundertheContracts(Rightsof
 ThirdParties)Act1999toenforceanytermoftheContract.Thisclause19.5doesnotaffect
 anyrightorremedyofanypersonwhichexistsorisavailableotherwisethanpursuanttothat
 Act.
19.6TheCustomeragreesthatitwillhavenoremedyinrespectofanyuntruestatement
 innocentlyornegligentlymadebyoronbehalfofGeorgeFischerpriortotheContractupon
 whichtheCustomerreliedinenteringintotheContractwhethersuchstatementwasmade
 orallyorinwritingunlessthestatementhasbeenexpresslyagreedinwritingbyadirector
 ofGeorgeFischerand/orthestatementhasbeenexpresslyincorporatedinwritingintothe
 Contract.
19.7GeorgeFischershallnotbeinbreachoftheseConditionsorotherwiseliabletotheCustomer
 byreasonofanydelayinperformanceornon-performanceofanyofitsobligationsduetoany
 circumstancesoutsideGeorgeFischer’sreasonablecontrol.
19.8TheContractwillbegovernedbyEnglishlawandthepartiessubmittothenon-exclusive 
 jurisdictionoftheEnglishcourts.
GEORGE FISCHER SALES LIMITED (“George Fischer”)
CONDITIONS OF SALE (FOR GOODS AND SERVICES) (Continued)
The above Terms of Business effective from 29th June 2007
George Fischer Sales Limited,
Paradise Way, Coventry CV2 2ST
Telephone: 024 7653 5535 Fax: 024 7653 0450
www.georgefischer.co.uk
email: uk.ps@georgfischer.com
LITGF0482 (04.09)
© George Fischer Sales Ltd.
GF Piping Systems > worldwide at home
Our sales companies and representatives
ensure local customer support in over 100 countries. www.georgescher.co.uk
Adding Quality to Peoples Lives
The technical data is not binding. They neither
constitute expressly warranted characteristics nor
guaranteed properties nor a guaranteed durability.
They are subject to modication. Our General Terms of
Sale apply.
Australia
George Fischer Pty Ltd
Riverwood NSW 2210 Australia
Phone +61(0)2 9502 8000
australia.ps@georgscher.com
www.georgescher.com.au
Austria
Georg Fischer
Rohrleitungssysteme GmbH
3130 Herzogenburg
Phone +43(0)2782 856 43-0
austria.ps@georgscher.com
www.georgscher.at
Belgium / Luxembourg
Georg Fischer NV/SA
1070 Bruxelles/Brüssel
Phone +32(0)2 556 40 20
be.ps@georgscher.com
www.georgscher.be
Brazil
George Fischer Ltda
04795-100 São Paulo
Phone +55(0)11 5687 1311
br.ps@georgscher.com
China
Georg Fischer
Piping Systems Ltd Shanghai
Pudong, Shanghai 201319
Phone +86(0)21 58 13 33 33
china.ps@georgscher.com
www.cn.piping.georgscher.com
Denmark / Iceland
Georg Fischer A/S
2630 Taastrup
Phone +45 (0)70 22 19 75
info.dk.ps@georgscher.com
www.georgscher.dk
France
Georg Fischer SAS
95932 Roissy Charles de Gaulle Cedex
Phone +33(0)1 41 84 68 84
fr.ps@georgscher.com
www.georgescher.fr
Germany
Georg Fischer GmbH
73095 Albershausen
Phone +49(0)7161 302-0
info.de.ps@georgscher.com
www.georgscher.de
India
Georg Fischer Piping Systems Ltd
400 076 Mumbai
Phone +91 224007 2001
in.ps@georgscher.com
www.georgscher.in
Italy
Georg Fischer S.p.A.
20063 Cernusco S/N (MI)
Phone +3902 921 861
it.ps@georgscher.com
www.georgscher.it
Japan
Georg Fischer Ltd
556-0011 Osaka,
Phone +81(0)6 6635 2691
jp.ps@georgscher.com
www.georgscher.jp
Korea
Georg Fischer Piping Systems
Guro-3 dong, Guro-gu, Seoul, Korea
Phone +82(0)2 2081 1450
Fax +82(0)2 2081 1453
kor.ps@georgscher.com
Malaysia
Georg Fischer (M) Sdn. Bhd.
40460 Shah Alam, Selangor
Phone +60 (0)3 5122 5585
conne.kong@georgscher.com
Mexico
Georg Fischer S.A. de C.V.
Apodaca, Nuevo Leon
CP66636 Mexico
Phone +52 (81)1340 8586
Fax +52 (81)1522 8906
Middle East
George Fischer Piping Systems
Dubai, United Arab Emirates
Phone +971 4 289 49 60
info.export@georgscher.com
www.export.georgscher.com
Netherlands
Georg Fischer N.V.
8161 PA Epe
Phone +31(0)578 678 222
nl.ps@georgscher.com
www.georgscher.nl
Norway
Georg Fischer AS
1351 Rud
Phone +47(0)67 18 29 00
no.ps@georgscher.com
www.georgscher.no
Poland
Georg Fischer Sp. z o.o.
02-226 Warszawa
Phone +48(0)22 313 10 50
poland.ps@georgscher.com
www.georgscher.pl
Romania
Georg Fischer
Piping Systems Ltd
020257 Bucharest - Sector 2
Phone +40(0)21 230 53 80
ro.ps@georgscher.com
www.export.georgscher.com
Russia
Georg Fischer Piping Systems
Moscow 125047
Tel. +7 495 258 60 80
ru.ps@georgscher.com
www.georgscher.ru
Singapore
George Fischer Pte Ltd
528 872 Singapore
Phone +65(0)67 47 06 11
sgp.ps@georgscher.com
www.georgescher.com.sg
Spain / Portugal
Georg Fischer S.A.
28046 Madrid
Phone +34(0)91 781 98 90
es.ps@georgscher.com
www.georgscher.es
Sweden / Finland
Georg Fischer AB
12523 Älvsjö-Stockholm
Phone +46(0)8 506 775 00
info.se.ps@georgscher.com
www.georgscher.se
Switzerland
Georg Fischer
Rohrleitungssysteme (Schweiz) AG
8201 Schahausen
Phone +41(0)52 631 30 26
ch.ps@georgscher.com
www.piping.georgscher.ch
Taiwan
Georg Fischer Piping Systems
San Chung City, Taipei Hsien
Phone +886 2 8512 2822
Fax +886 2 8512 2823
United Kingdom / Ireland
George Fischer Sales Limited
Coventry, CV2 2ST
Phone +44(0)2476 535 535
uk.ps@georgscher.com
www.georgescher.co.uk
USA / Canada / Latin America / Caribbean
Georg Fischer LLC
Tustin, CA 92780-7258
Phone +1(714) 731 88 00
Toll Free 800 854 40 90
us.ps@georgscher.com
www.us.piping.georgescher.com
International
Georg Fischer
Piping Systems (Switzerland) Ltd.
8201 Schahausen
Phone +41(0)52 631 30 03
Fax +41(0)52 631 28 93
info.export@georgscher.com
www.export.georgscher.com

Navigation menu