ImproX (iTT) Intelligent Twin Antenna Terminal Impr Xi TT Psc En 07
User Manual: ImprXiTT-psc-en-07
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
XTT910-1-0-GB-XX XTT931-1-0-GB-XX XTT920-1-0-GB-XX IPS910-1-0-GB-XX XTT930-1-0-GB-XX IPS911-1-0-GB-XX XXX9XX-X-X-GB-XX Read/Write capability using the following Impro Tags: Slim Tags and Omega Tags (Read Only). Philips HITAG™ 1 and Philips HITAG™ 2 (Read/Write). HID 125 kHz Tags (Read Only). NOTE: The ImproX (iTT) Intelligent Twin Antenna Terminal is the second generation of the highly successful ImproX TT. Using either the RS485 Bus or the RJ45 Ethernet Connection, the ImproX iTT works within the ImproX range of Access Control Systems, as well as within OEM applications. The ImproX iTT is a low-cost Terminal designed to provide access control to one door in Full Antipassback Mode (APB) or two doors in Relaxed Anti-passback Mode (APB) or single-entry mode. Impro offer a wide range of Antenna Readers suitable for most installations. Major memory improvements allow the ImproX iTT to store up to 10 000 Transactions as well as providing the added benefit of off-line validation. In this optional mode the ImproX iTT allows access to Tags present in the Terminal’s transaction buffer. This is valuable should communications between the ImproX iTT and the Controller disrupt. A 16-Step Auto-tune process provides improved communication range, letting you install the Terminal up to 25 m (82 ft) from its Non-keypad Antenna Reader and up to 16 m (53 ft) from its Keypad Antenna Readers. Other new features include a Software Utility that lets you upgrade the Terminal while installed on site with zero down-time. And the iTT now interfaces with various Relay driven lock types (including Strike Locks, Magnetic Door Locks and Deadbolts). HID is a registered trademark of HID Global Corporation (an ASSA ABLOY Group Brand). Onboard intelligence allowing the Terminal to run off-line from the Controller. The Terminal stores up to 10 000 Transactions. 16-step Auto-tune that allows for increased cable distances of up to 25 m (82 ft) for Non-keypad Antenna Readers and up to 16 m (53 ft) for Keypad Antenna Readers. End-of-Line (EOL) Sensing on Door Open Sensor (DOS) Inputs. Connection to up to two Antenna Readers per ImproX iTT, allowing Relaxed or Full Anti-passback (APB) access. An excellent user interface consisting of 9 LED “Diagnostic Indicators”. Two independent single-pole, double-throw (SPDT) Relay Outputs which let you interface to door strikes, magnetic locks and other third-party devices (for example alarms panels or lighting). Four Dry Contact Digital Inputs including two Door Open Sensor (DOS) and two Request to Exit (RTE) Inputs. A Software utility to upgrade Firmware while installed on-site, without removal of the Terminal. A 3 Amp Switch Mode Power Supply providing 13.8 V DC to charge a 12 V 7 Ahr Sealed Lead Acid Battery. Nominal output voltage of 13.8 V DC with a fully charged Battery. Automatic switch-over to Battery operation on Mains Failure. Compact, Mild Steel Cabinet, accommodating the Power Supply, Terminal and a Sealed Lead Acid Battery. Two 13.8 V Power Outputs for powering the Terminal and, for example, a lock. Together these Outputs have a maximum power output of 2 A (max) continuous at 13.8 V DC. Five Quick Click Glands for easy wiring. Fuses on mains in and low voltage out. Relay functions are user configurable. Digital Inputs are user configurable and can perform specific tasks such as: Door Open Sensing. Request to Exit. Scanner Inhibit. Alarm Interface. Action Request. XTT910 and XTT920 Plastic Housing Length : 128 mm (5 in). Width : 166 mm (7 in). Height : 55 mm (2 in). Approximate Weight : 302 g (11 oz). Cost effective solution that fits seamlessly into legacy Systems. Support for the following Terminal Communication options: Cabinet Material : ABS Plastic. Ethernet—Door Controllers (XTT920 and IPS911 only) connect to your chosen System Controller using the existing IP infrastructure. Colour : Black. RS485—an ultra reliable method (not affected by network problems) of connecting to your chosen System Controller. XTT930 and XTT931 PCB Only Length : 107 mm (4 in). Width : 110 mm (4 in). Height : 23 mm (1 in). Approximate Weight : 105 g (4 oz). The Power Supply then effectively shuts down as directed by its built in protection as exceeding the 3 A rating is considered a shortcircuit. Overcome this by installing the recommended 12 V 7 Ahr Battery to help supplement the in-rush current such a device may draw on activation. Power Input Input Voltage IPS910 and IPS911 Power Supply Combo : 85 V AC to 265 V AC at 50/60 Hz. Power Output Length : 305 mm (12 in). 13.8 V DC ±0.3 V DC. : 295 mm (11 in). Output Voltage (Mains Power On). : Width Height : 77 mm (3 in). Output Current : Approximate Weight : 3 kg (7 lb). 2 A continuous (Power Output Terminals). Cabinet Material : Mild Steel. Type : Colour : Black. 12 V Sealed Lead Acid Battery, 7 Ahr (Max). Length : 151 mm (6 in) (Max). Width : 65 mm (3 in) (Max). Height : 99 mm (4 in) including the Terminals (Max). Charge Voltage : 13.8 V DC. Battery Operating Temperature : -25°C to +60°C (-13°F to +140°F). Storage Temperature : -40°C to +80°C (-40°F to +176°F). Humidity Range : 0 to 95% relative humidity at +40°C (+104°F) non-condensing. Approvals The following specifications are common to all models of the ImproX iTT: CE Approval : EN301 489-1 and EN301 489-3. FCC Approval : Pending. Dust & Splash Resistance (XTT910 and XTT920) : Designed to work in an indoor (dry) environment similar to IP40. The Terminal is not sealed against water. Real Time Clock Backup Battery (RTC) Battery Type : 1 x 3 V, CR2032, Lithium cell battery. Dust & Splash Resistance (XTT930 and XTT931) : Designed to work in an indoor (dry) environment. The Terminal is not sealed against water. Battery Life : 1 Year with Power OFF, 5 years with power ON, 5 years storage with Battery Tab in place. Dust & Splash Resistance (IPS910) : Designed to work in an indoor (dry) environment similar to IP20. The Power Supply Combo is, therefore, not sealed against water. Drop Endurance : 1 m (3.28 ft) drop (in packaging). Relay Power Requirements : An additional ~0.4 W per Relay in use. Ethernet Port (XTT920, XTT931 and IPS911) Ethernet Port : Standard Ethernet RJ45 connector. 10/100 Base T, half or full duplex. Electrical Interface : RS485, ASCII with 16-bit CRC checking. Baud Rate : 9 600, 19 200, 38 400 (default), 57 600 and 115 200 selectable via the Communications Protocol. RS485 Terminal Bus XTT910, XTT920, XTT930, XTT931 Input Voltage : Power Requirements 10 V DC to 30 V DC, polarity sensitive. Current (mA) Power (W) Data Format : 8 data bits, no parity, 1 stop bit. Communications Protocol : ImproX Secure Communications Protocol. Line Termination (RS485) : Provision is made for line termination. Unit Status : Slave. Antenna Port : 2 Fully functional Antenna Reader Ports. Input Type : 2 Dry-contact inputs with End-of-line (EOL) Sensing and 2 Dry-contact inputs without End-of-line (EOL) Sensing. Detection Resistance Range : < 2 kOhm. Protection Range : +15 V continuous. Relay Output : 2 Independent, single-pole, doublethrow (SPDT) Relays, each with NO, COM and NC contacts. Input Voltage 12 V DC with no Antennas attached : 90 1.08 Input Voltage 24 V DC with no Antennas attached : 50 1.20 Input Voltage 12 V DC with Antennas attached : 100 1.20 Input Voltage 24 V DC with Antennas attached : 60 1.44 Permissible Input Supply Ripple Voltage (Max) : 1 V PP at 50 Hz. Power Input Protection : Reverse polarity, over-voltage and over-current protection are provided on the Terminal. IPS910 and IPS911 Power Supply Combo The Power Supply Combo includes a 3 A Switch Mode Power Supply which provides power for the (optional) internal unit and for charging the (optional) backup Battery. As the Power Supply Combo needs no more than 1 A, you may power extra devices using up to 2 A continuous current from the provided connector block. DO NOT exceed this 2 A limit on continuous current draw. Devices with a high in-rush current demand, such as certain maglocks and other electromechanical devices, can momentarily draw more than 3 A. Page 2 Contact Ratings : 10 A at 28 V DC, 5 A at 220 V AC, 12 A at 120 V AC. Order the ImproX iTT using the following Part Numbers: Operations : 100 000 Minimum. XTT910-1-0-GB-XX: ImproX (iTT) Intelligent Twin Antenna Terminal in an ABS Plastic Housing. XTT920-1-0-GB-XX: ImproX (iTT) Intelligent Twin Antenna Terminal with Ethernet in an ABS Plastic Housing. XTT930-1-0-GB-XX: ImproX (iTT) Intelligent Twin Antenna Terminal PCB Only. XTT931-1-0-GB-XX: ImproX (iTT) Intelligent Twin Antenna Terminal with Ethernet PCB Only. IPS910-1-0-GB-XX: ImproX IPS containing an ImproX (iTT) Intelligent Twin Antenna Terminal. IPS911-1-0-GB-XX: ImproX IPS containing an ImproX (iTT) Intelligent Twin Antenna Terminal with Ethernet. Type : 32-bit ARM7TDMI operating at 72 MHz. Total RAM : 58 K Byte. Flash : 256 K Byte. Default Baud Rate : Factory-set to 38 400. Default Mode : Receive (Slave Mode). Buzzer Volume : Level 3 (maximum). Fails Power-on Self-test : Continuous beep for 2 seconds. Passes Power-on Selftest : Two short beeps of 200 ms duration, separated by a 200 ms inter-beep pause. Anti-tamper Switch : 1 Internal Switch. Status LED : Continuous Red. Upgrade Mode : Flashing Red (Steady). Communications Failure : Flashing Red (Intermittent). Relay [2] : Continuous Red on activation of the Relay. Relay [1] : Continuous Red on activation of the Relay. Reader 2, RTE [2] : Continuous Green on detected contact closure. Reader 2, DOS [1] : Continuous Green on detected contact closure. Reader 1, RTE [2] : Continuous Green on detected contact closure. Reader 1, DOS [1] : Continuous Green on detected contact closure. RS485 RX : Flashing Green as per incoming data. RS485 TX : Flashing Red as per outgoing data. Beep Codes CAUTION: We reserve the right to nullify the products warranty where you have not properly installed the Metal-oxide Varistors. This product conforms to our Warranty details on www.impro.net. Ethernet LEDs (XTT920, XTT931 and IPS911 Only) Ethernet Activity : Flashing Red LED. Ethernet Speed : Continuous Red for 100 Mbps (Default) Off for 10 Mbps. Ethernet Link : Continuous Red on connection to network. For extra information relating to this product refer to the: ImproX iTT Hardware Installation Manual (XTT303-0-0-GB-XX). Page 3 Figure 1: ImproX iTT Overview This Product Specification Catalogue applies to the ImproX (iTT) Intelligent Twin Antenna Terminal, XTT910-1-0-GB-09, XTT920-1-0-GB-09, XTT930-1-0-GB-01, XTT931-1-0-GB-01, IPS910-1-0-GB-05 and IPS911-1-0-GB-05. (The last two digits of the Impro stock code point to the issue status of the document or product). XTT360-0-0-GB-06 Issue 07 November 2011 ImproX iTT\Product Specification Catalogue\LATEST ISSUE\ ImprXiTT-psc-en-07.docx Page 4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Creator : Shannon Frances Description : ImproX (iTT) Intelligent Twin Antenna Terminal Title : ImproX (iTT) Intelligent Twin Antenna Terminal Create Date : 2011:11:30 10:43:53Z Creator Tool : Microsoft® Office Word 2007 Modify Date : 2011:11:30 12:46:24+02:00 Metadata Date : 2011:11:30 12:46:24+02:00 Producer : Microsoft® Office Word 2007 Document ID : uuid:ae3442e1-8595-4ca3-ad9d-ceea61720b9f Instance ID : uuid:b85b42bf-8330-45d8-b31b-fb49a0a91220 Page Layout : SinglePage Page Mode : UseOutlines Page Count : 4 Author : Shannon Frances Keywords : ImproX, (iTT), Intelligent, Twin, Antenna, Terminal Subject : ImproX (iTT) Intelligent Twin Antenna TerminalEXIF Metadata provided by EXIF.tools