COATED INSULATION BOARDS (INSBOARD)

Using Warmup® Insulation Boards with underfloor
heating can lower your running costs by as much
as 50% while reducing your carbon footprint. In
fact, they can pay for themselves in as little as 2.5
years.*
Warmup® Insulation Board is a water resistant,
insulated tile backer board made of extruded

Warmup Insulation Board Size Guide

polystyrene, faced on both sides with a fibreglass
THICKNESS
(mm)

WIDTH
(mm)

LENGTH
(mm)

WEIGHT
(kg)

R VALUE
(m2.K/W)

INSBOARD6MM

6

600

1250

1.95

0.16

INSBOARD(PK1)

10

600

1250

2.22

0.28

INSBOARD20MM

20

600

1250

2.48

0.58

INSBOARD50MM

50

600

1250

3.26

1.50

MODEL

mesh embedded into a thin cement polymer mortar.
The board is designed to withstand a load of 30
tonnes per square metre and is ideal for use with
underfloor heating as it prevents the heat from
penetrating down into the substrate below.
As a wall tile backer board, tiles can be fixed directly
onto the surface without prior preparation and,
being totally waterproof, is suitable for wet areas

Accessories
Glass Fibre Tape - The tape helps prevent any movement and is used
to cover the joints. One roll per 25 boards.

such as bathrooms and wet rooms. The boards have
a tile load weight of 62kg/m2, to support heavy tiles.

Features and Benefits:
•

•
•

•

Highly Efficient - Can reduce underfloor heating
heat up times to less than 30 minutes as opposed to
2+ hours without insulation**
Value - can pay for itself in as little as 2.5 years*,**
Sole Source of Heat - Allows Warmup to be the sole
source of heat in properties built to current building
regulations (a heat loss calculation is always required)
Effective - Reduces running costs

•
•
•
•

Structural Benefits - High compressive strength and
waterproofing properties
Satisfaction - Enhances customer satisfaction by
reducing heat-up times
Cost Savings - Reduces the need for additional heat
source on the whole project
Improved Tile Adhesion - High grab factor. Does not
delaminate

*Assumes a system running twice a day for two hours on a concrete subfloor **Source: Warmup tests performed to EN442-2 standards, using 10mm board

Technical Data:
•
•
•
•
•
•
•
•
•

Board dimensions: 1250mm x 600mm
Area: 0.75 m2
Density: 36 kg/m3
Compressive strength: 3.0 kg/cm2 (300kN/m2)
Water absorption (capillary): Nil
Board thickness: 6mm, 10mm, 20mm, 50mm
Water vapour permeability (Sd): 3.2m
Resistance to body impact: 3x120N/m
Bending stiffness, EI: (20mm) 601kNmm2
		
(30mm) 1285 kN/mm2

•
•
•
•
•
•
•
•
•

Tile loading weight 62kg/m2
No primer required when used in conjunction with
underfloor heating
Bond strength: 0.3N/mm2
Shear bond strength: 3.32/kg/cm2
Thermal conductivity: 0.027 W/mK
Coefficient of linear expansion: 30 x 10-6 K-1
Class “O” / “B1” fire rated
Fire ignitability: “P” not easily ignitable
Impact sound reduction: dLw = 21

Warmup Plc | 702 Tudor Estate Abbey Road London NW10 7UW | Tel +44208 453 6868 | Fax +44208 453 6869 | E-mail int@warmup.com | Web www.warmup.co.uk
The WARMUP word and associated logos are trade marks. © Warmup Plc. 2015 - Regd. TM Nos. 1257757, 4409926, 5265707. E & OE. Registered in England No. 2955213.

v.200415



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2015:07:17 09:41:45+01:00
Metadata Date                   : 2015:07:17 09:41:46+01:00
Modify Date                     : 2015:07:17 09:41:46+01:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:7c62700c-aea6-4649-8460-6be7dbd0e974
Original Document ID            : xmp.did:FA6FFF916AA4DF11B994D7704856581A
Document ID                     : xmp.id:F5AFCF9E5F2CE511B225F806750C3417
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:F4AFCF9E5F2CE511B225F806750C3417
Derived From Document ID        : xmp.did:33D7394A57E7E41181CB8C2AA59762E8
Derived From Original Document ID: xmp.did:FA6FFF916AA4DF11B994D7704856581A
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2015:07:17 09:41:45+01:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 1
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu