KX TD 208 Telephone System Getting Started Manual
Panasonic KX-TD208 telephone system Getting Started Manual KX-TD208_telephone_system_Getting_Started_Manual Panasonic KX-TD208 Digital Systems Manuals - Telecomuserguides.com
User Manual: KX-TD 208 telephone system Getting Started Manual
Open the PDF directly: View PDF .
Page Count: 12
Download | |
Open PDF In Browser | View PDF |
Digital Super Hybrid System KX-TD208E g Star n i t ted et G This booklet tells you how to install your KX-TD208 quickly and easily and gives you initial operating instructions. For further information, see the enclosed "Operating lnstructions." Contents Preparation Describes the included accessories and required tools for installation. Page 3 Connection Shows you how to install your system from set-up to initial use. Page 4 Basic Programming Describes the programs necessary depending on your contract and requirements. Basic Operations Page 6 Describes how to make and receive calls in order to confirm the connections. Programming Using A Personal Computer Page 8 Shows you a personal computer connection and how to program by using it. Page 9 Assistance Information Page 11 IBM is a registered trademark of International Business Machines Corporation. MS-DOS® is registered trademark of Microsoft Corporation in the United States and/or other countries. All other trademarks identified herein are the property of their respective owners. •••2••• Preparation Before installing your system ¢ Check the package contents. The included materials are: DIGITAL SUPER HYBRID SYSTEM POWER Floppy Disk for PC Programming ... one Screws and Washers ... three Main Unit ... one AC Cord ... one *Do not close the transparent part into the black part before inserting the wires. 4-pin Plugs* ... eleven ISDN Line Cord ... one ¢ Necessary user-supplied tools: ✔ Phillips screwdriver and flathead screwdriver ✔ Electrician’s pliers ✔ Telephone company contract ✔ Serial printer cable to connect a PC to the telephone system ✔ Telephone sockets to connect the telephone equipment, if required ✔ Wire (solid wire) for the extension connection: Conductor diameter: Ø 0.4 – 0.6mm Diameter with coating: Ø 0.66 – 1.05mm •••3••• Connections 1. Open the front cove Reset Switch 2. Connect the include ISDN Port 2 ISDN Port 1 ISDN Modular Jack 3. Connect the user A B EXTN.1 D I G I T A L S U P E R H Y B R I D S Y S TEM POWER Preparation 1. Extension Jack To the "Extension Jack" RS-232C Port (Serial Interface) User-supplied Telephone Socket Strip the wire cover with pliers. 4. socke cover scre Remove the socket cover with flathead screwdriver. 4. Connect the PC to You can program the syste The required operating syste 5. Close the front cove PC DIGITAAL SUPER HYBRIDE SYSTEEM To AC Outlet POWER Tie together all of the connected cords and attach them to the wall so that they cannot be pulled out of the unit. •••4••• 1. Loosen the screw. 2. Slide the cover toward the right DIGITAL SUPER HYBRID SYSTEM while pressing the " " mark. POWER screw ISDN line cord to "ISDN Port 1" and the Telephone socket to the exchange line. To the Exchange Line supplied extension line cord to the "Extension Jack" and telephone equipment. A 2. 3. A B B Insert the user-supplied telephone wires completely into the holes of the included plugs. 5. Press the transparent part into the black part firmly. Note hole A B 1 6 5 4 2 3 5 2 Insert the other end of the wires into the hole on the back and tighten both screws by the driver. ¥For installing proprietary telephones, ¥The maximum length of the extension line cords an optional PT Interface Card to the extensions are; (KX-TD20870CE) should be installed on your system. Line Diameter Max. Length 0.6mm 620m Please refer to the Operating SLT 0.6mm PT Instructions for details. 240m the RS-232C port. data using TD208.EXE file in the included floppy disk on the IBM-PC/AT or compatible personal computer (PC). OS) is Version 5.0 or later versions of MS-DOS. and connect the AC cord to the AC inlet and AC outlet. AC Inlet EXTN. 8 EXTN. 7 EXTN. 6 EXTN. 5 EXTN. 4 EXTN. 3 EXTN. 2 1. Slide the cover in the direction of the arrow. EXTN. 1 D I G I T A L S U P E R H Y B R I D S Y S TE M 2. Tighten the screw. POWER screw •••5••• Basic Programming Some programming is required for basic operation. Check your contract with the telephone company and program as needed. The following flow chart will tell you which programming is required for your system. Please program your system accordingly. Before programming Connect a tone-type single line telephone to jack number 1 for programming. Check: • Your telephone is on-hook. • No calls are on hold at your telephone. Programming type selection Your contract is: 1: Point-to-Multi-point 2: Point-to-Point 1 2 Does your contract apply to a DDI service? Do you want to specify the receiving extension? Type No Yes No Yes A B C D Programming Step 1. Enter into the programming mode. 5 1 Off-hook 2 3 4 Password (Default) Dial tone 3 Step 2. Program [404] to all the types A, B, C, D. [404] CLIP / COLP Number Assignment 4 0 4 ISDN port no. (1,2, ) extension no. X CLIP/COLP no. 21 through 28, (1···4, ) 20 digits max. (0···9) 31 through 34, 301 through 308 X – CLIP / COLP Classfication (ISDN ext.), 1 : CLIP no. Business 2 : CLIP no.-Private 300 (all ISDN ext.) 3 : COLP no.-Business 4 : COLP no.-Private : All (Continued) •••6••• Basic Programming Step 3. Follow the chart according to your programming type . A B C D [406] ISDN Configuration 4 0 6 ISDN port no. (1,2, 1 ) [407] Multiple Subscriber Number (MSN) Set 4 0 7 ISDN location MSN port no. no. 16 digits max. (1,2, ) (01···10) (0···9) [408]–[409] Extension Ringing Assignment —Day / Night for ISDN Consecutive entries 4 ISDN location extension no. port no. no. (21 ... 28, 31...34) Y - Day...8 (1,2, ) (01···10) Night...9 0 Y delayed ring time 0: immediate 1: 1 ring delay 3: 3 rings delay 6: 6 rings delay 9: disable [405] Direct Dialling In 4 A B C 0 5 ISDN port no. (1,2, 2 ) D [412] ISDN DDI Number / Extension Number Transformation 4 1 2 ISDN port no. (1,2, ) DDI no. 20 digits max. 21 through 28, (0···9) 31 through 34, 301 through 308, 300, 291 through 298 (UCD Group or Ring Gruop) extension no. Go to Step 4. Step 4. Exit from the programming mode. Press Reset Switch. On-hook •••7••• Basic Operations Let’s try to make and receive a call in order to confirm the connections. Making a call to another extension and receiving it ¢ Making a call from extension 21 to extension 22 At extension 21 1. Off-hook. 2. Dial 2 2 . At extension 22 1. Off-hook. Did it work??? Making a call to an outside party ¢ Calling a Speaking Clock 1. Off-hook. 2. Enter 9 3. Dial 1 . 2 3 . Can you hear the time announcement? •••8••• Programming Using A Personal Computer Connection EXTN. 8 EXTN. 7 EXTN. 6 EXTN. 5 EXTN. 4 HING SYSTEM EXTN. 3 EXTN. 2 EXTN. 1 Connect your personal computer to the RS232C port with the usersupplied serial printer cable. The Cable must be shielded and the maximum length is 2 m. ¢ Refer to the following chart for the pin configuration; Port on your system 9-pin port on a PC Pin No. Pin No. Signal Name Circuit Type (EIA) 2 2 RXD BB 3 4 3 4 TXD DTR BA CD 5 6 5 6 SG DSR AB CC 7 8 7 8 RTS CTS CA CB •••9••• Programming Using A Personal Computer Programming You can program the system data using the application software in the included floppy disk on the IBM-PC/AT or a compatible personal computer. The system programming data can be stored either on the floppy disk or on your hard disk. To use the floppy disk for PC programming, you must have MS-DOS (or equivalent) version 5.0 or later. A minimum of 450K of free conventional memory is required. ¢ File Configuration The file name: TD208.EXE (Execution file) You may store the following files if desired. Database file: *.DBF ASCII file: *.DBA Screen save file: P208.PRT ! £ The “*” represents the file name of your choice. (up to 8 characters) ¢ Setup 1. Insert the floppy disk into drive A. 2. Change the current directory to drive A. 3. Type TD208 after confirming the sign “>” and press the Enter key. – The initial screen appears. ! £ After the initial screen appears, you can remove the included disk and insert a database file disk to save the data. £ If your monitor is monochrome and you cannot see the cursor easily, exit the programming mode and re-type TD208/MONO. £ If you need an explanation of the system and its operations, press F4 (Help) on the initial screen. A Help screen will appear. £ This program is guaranteed to work with MS-DOS only. It is not guaranteed with MS-DOS in Windows. • • • 10 • • • Assistance Information If you have any trouble, see the Trouble Shooting Section in the Operating Instructions or consult your dealer. • • • 11 • • • Printed in Japan PSQX1258YA KK0497KM1068
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res Create Date : 1998:07:30 21:33:41 Producer : Acrobat Distiller 3.0 for Power Macintosh Modify Date : 1999:05:07 17:00:09 Page Count : 12EXIF Metadata provided by EXIF.tools