Digital Super Hybrid System

KX-TD208E

g Star
n
i
t
ted
et
G

This booklet tells you how to install your KX-TD208 quickly and easily
and gives you initial operating instructions.
For further information, see the enclosed "Operating lnstructions."

Contents
Preparation
Describes the included
accessories and required
tools for installation.
Page 3

Connection
Shows you how to install
your system from set-up to
initial use.
Page 4

Basic
Programming
Describes the programs necessary depending on your
contract and requirements.

Basic
Operations

Page 6

Describes how to make and
receive calls in order to
confirm the connections.

Programming
Using A Personal
Computer

Page 8

Shows you a personal computer connection and how to
program by using it.
Page 9

Assistance
Information
Page 11

IBM is a registered trademark of International Business Machines Corporation.
MS-DOS® is registered trademark of Microsoft Corporation in the United States and/or other countries.
All other trademarks identified herein are the property of their respective owners.

•••2•••

Preparation
Before installing your system
¢ Check the package contents. The included materials are:

DIGITAL SUPER HYBRID SYSTEM

POWER

Floppy Disk for PC
Programming ... one

Screws and Washers
... three

Main Unit ... one

AC Cord ... one

*Do not close
the transparent
part into the black
part before inserting the wires.

4-pin Plugs* ... eleven

ISDN Line Cord ... one

¢ Necessary user-supplied tools:
✔ Phillips screwdriver and flathead screwdriver
✔ Electrician’s pliers
✔ Telephone company contract
✔ Serial printer cable to connect a PC to the telephone system
✔ Telephone sockets to connect the telephone equipment, if required
✔ Wire (solid wire) for the extension connection:
Conductor diameter:
Ø 0.4 – 0.6mm
Diameter with coating:
Ø 0.66 – 1.05mm

•••3•••

Connections
1. Open the front cove
Reset Switch

2. Connect the include
ISDN Port 2
ISDN Port 1
ISDN Modular Jack

3. Connect the user A
B

EXTN.1

D I G I T A L S U P E R H Y B R I D S Y S TEM

POWER

Preparation
1.

Extension Jack
To the "Extension Jack"
RS-232C Port
(Serial Interface)

User-supplied
Telephone
Socket

Strip the wire cover
with pliers.

4.

socke
cover
scre
Remove the socket
cover with flathead
screwdriver.

4. Connect the PC to
You can program the syste
The required operating syste

5. Close the front cove
PC
DIGITAAL SUPER HYBRIDE SYSTEEM

To AC Outlet

POWER

Tie together all of the connected cords
and attach them to the wall so that they
cannot be pulled out of the unit.

•••4•••

1. Loosen the screw.
2. Slide the cover toward the right

DIGITAL SUPER HYBRID SYSTEM

while pressing the " " mark.

POWER

screw

ISDN line cord to "ISDN Port 1" and the Telephone socket to the exchange line.

To the Exchange Line

supplied extension line cord to the "Extension Jack" and telephone equipment.

A

2.

3.
A
B

B

Insert the user-supplied telephone
wires completely into the holes of
the included plugs.

5.

Press the transparent part into the
black part firmly.

Note
hole

A
B

1
6
5
4

2
3

5
2

Insert the other end of the wires
into the hole on the back and
tighten both screws by the driver.

¥For installing proprietary telephones, ¥The maximum length of the
extension line cords
an optional PT Interface Card
to the extensions are;
(KX-TD20870CE) should
be installed on your system.
Line Diameter Max. Length
0.6mm
620m
Please refer to the Operating
SLT
0.6mm
PT
Instructions for details.
240m

the RS-232C port.
data using TD208.EXE file in the included floppy disk on the IBM-PC/AT or compatible personal computer (PC).
OS) is Version 5.0 or later versions of MS-DOS.

and connect the AC cord to the AC inlet and AC outlet.
AC Inlet

EXTN.
8
EXTN.
7
EXTN.
6
EXTN.
5
EXTN.
4
EXTN.
3
EXTN.
2

1. Slide the cover in the direction of the arrow.

EXTN.
1

D I G I T A L S U P E R H Y B R I D S Y S TE M

2. Tighten the screw.

POWER

screw

•••5•••

Basic Programming
Some programming is required for basic operation. Check your contract
with the telephone company and program as needed. The following flow
chart will tell you which programming is required for your system. Please
program your system accordingly.

Before programming
Connect a tone-type single line telephone to jack number 1 for programming.
Check: • Your telephone is on-hook.
• No calls are on hold at your telephone.

Programming type selection
Your contract is:
1: Point-to-Multi-point
2: Point-to-Point
1

2
Does your contract apply
to a DDI service?

Do you want to specify
the receiving extension?

Type

No

Yes

No

Yes

A

B

C

D

Programming
Step 1. Enter into the programming mode.
5

1

Off-hook

2

3

4

Password (Default) Dial tone 3

Step 2. Program [404] to all the types A, B, C, D.
[404] CLIP / COLP Number Assignment
4

0

4

ISDN
port no.
(1,2,

)

extension no.
X
CLIP/COLP no.
21 through 28, (1···4, )
20 digits max. (0···9)
31 through 34,
301 through 308
X – CLIP / COLP Classfication
(ISDN ext.),
1 : CLIP no. Business 2 : CLIP no.-Private
300 (all ISDN ext.)
3 : COLP no.-Business 4 : COLP no.-Private
: All

(Continued)

•••6•••

Basic Programming
Step 3. Follow the chart according to your programming type .

A

B

C

D

[406] ISDN Configuration
4

0

6

ISDN
port no.
(1,2,

1

)

[407] Multiple Subscriber Number (MSN) Set
4

0

7

ISDN location
MSN
port no.
no.
16 digits max.
(1,2, ) (01···10)
(0···9)

[408]–[409] Extension Ringing Assignment
—Day / Night for ISDN
Consecutive entries

4

ISDN location
extension no.
port no.
no.
(21 ... 28, 31...34)
Y - Day...8 (1,2, ) (01···10)
Night...9

0

Y

delayed ring time

0: immediate
1: 1 ring delay
3: 3 rings delay
6: 6 rings delay
9: disable

[405] Direct Dialling In
4

A

B

C

0

5

ISDN
port no.
(1,2,

2

)

D

[412] ISDN DDI Number / Extension Number Transformation
4

1

2

ISDN
port no.
(1,2, )

DDI no.
20 digits max.
21 through 28,
(0···9)
31 through 34,
301 through 308, 300,
291 through 298
(UCD Group or Ring
Gruop)
extension no.

Go to Step 4.
Step 4. Exit from the programming mode.
Press Reset Switch.
On-hook

•••7•••

Basic Operations
Let’s try to make and receive a call in order to confirm the connections.

Making a call to another extension and receiving it
¢ Making a call from extension 21 to extension 22

At extension 21

1. Off-hook.
2. Dial

2

2

.

At extension 22

1. Off-hook.

Did it work???

Making a call to an outside party
¢ Calling a Speaking Clock
1. Off-hook.
2. Enter

9

3. Dial

1

.
2

3

.

Can you hear the time announcement?

•••8•••

Programming Using A Personal Computer
Connection

EXTN.
8
EXTN.
7
EXTN.
6
EXTN.
5
EXTN.
4

HING SYSTEM

EXTN.
3
EXTN.
2
EXTN.
1

Connect
your personal
computer to the RS232C port with the usersupplied serial printer
cable. The Cable must
be shielded and the
maximum length
is 2 m.

¢ Refer to the following chart for the pin configuration;

Port on your system

9-pin port on a PC

Pin
No.

Pin
No.

Signal
Name

Circuit
Type
(EIA)

2

2

RXD

BB

3
4

3
4

TXD
DTR

BA
CD

5
6

5
6

SG
DSR

AB
CC

7
8

7
8

RTS
CTS

CA
CB

•••9•••

Programming Using A Personal Computer
Programming
You can program the system data using the application software in the included
floppy disk on the IBM-PC/AT or a compatible personal computer. The system programming data can be stored either on the floppy disk or on your hard disk.
To use the floppy disk for PC programming, you must have MS-DOS (or equivalent)
version 5.0 or later. A minimum of 450K of free conventional memory is required.
¢ File Configuration
The file name: TD208.EXE (Execution file)
You may store the following files if desired.
Database file: *.DBF
ASCII file: *.DBA
Screen save file: P208.PRT

!

£ The “*” represents the file name of your choice. (up to 8 characters)

¢ Setup

1. Insert the floppy disk into drive A.
2. Change the current directory to drive A.
3. Type TD208 after confirming the sign “>” and press the Enter key.
– The initial screen appears.

!

£ After the initial screen appears, you can remove the included disk and insert
a database file disk to save the data.
£ If your monitor is monochrome and you cannot see the cursor easily, exit the
programming mode and re-type TD208/MONO.
£ If you need an explanation of the system and its operations, press F4 (Help)
on the initial screen. A Help screen will appear.
£ This program is guaranteed to work with MS-DOS only. It is not guaranteed
with MS-DOS in Windows.

• • • 10 • • •

Assistance Information
If you have any trouble, see the Trouble Shooting Section in the Operating Instructions or
consult your dealer.

• • • 11 • • •

Printed in Japan

PSQX1258YA KK0497KM1068



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res
Create Date                     : 1998:07:30 21:33:41
Producer                        : Acrobat Distiller 3.0 for Power Macintosh
Modify Date                     : 1999:05:07 17:00:09
Page Count                      : 12
EXIF Metadata provided by EXIF.tools

Navigation menu